Macopress Smart The automatic blood separator Designed to ease your work Macopress Smart 1275 The automatic blood separator Designed to ease your work Principle MACOPRESS Smart (MPS) is an automate intended for the separation of a whole blood unit into blood components. It is compatible with all blood bags currently available. The MPS can operate as an independent unit or it can be connected to a distant computer and supervised by the DMS+ Data Management System. The REVO Innovation With integrated cannula breakers and red cell mixer. • Vertical scale (a) a • Optional hook (h) h • Cannula breaker (b) • Tube position & indicators (i) • Flow regulator (c) b • Display (j) • Top optic sensors (d) • Main scale (k) • Cannula breaker (e) c f d • Lateral scale with easy bag insertion (f) g i • Red cell mixer (l) e k j • Lateral press (g) • Cannula breaker (m) l m The REVO Innovation Unique system of three universal cannula breakers * including in-process red cell mixing All opening and mixing functions are fully programmable and controlled by the MACOPRESS Smart program. Manual cannula breaking is time consuming and can cause RSI** and haemolysis. Our system has proven to be effective, reduces time and generates reproducibility and standardisation. REVO comprises the following modules: • Integrated automatic cannula breaker for the main bag. Ref: 9MPSBRK01 • Semi-Integrated automatic cannula breaker for the additive solution. Ref: 9MPSBRK02 • Automatic cannula breaker and red cell mixer. External unit connected to the MACOPRESS Smart able to break standard single and double cannula while mixing the red cell with additive solution. Ref: 9MPSBRK03 *Please refer the instructions for use **RSI: Repetitive Strain Injuries Quality and Safety • The optical sensors and flow regulator contribute to the production of high quality and pure blood components. All sensors have a self adjusting function. • A smart panel indicates the correct positioning of tubes in clamps from START to END of procedure. • Automatic break-away cannula breaker for all bag systems. • Graphic backlit LCD display with userfriendly menu, allowing easy change of most parameters. Press System • Main and Lateral press with electronic motion controlled with a dedicated microprocessor (no requirement for compressed air). • Lateral press designed for high yield of plasma and air extraction. Controlled press parameter: speed, pressure, sensor and position. Eight optical sensors for detecting and maintaining the BC (buffy-coat) layer. Two additional sensors on top, all with fully adjustable sensitivity. Synchronous separation of T&B (Top & Bottom) bag systems. Flexibility • Memory up to 50 programs. • 5 different user levels with access control. • Up to 5 integrated scales recording weights of all blood components, including whole blood. • Five programmable sealing clamps for automatic or manual operation; can also be used as separate sealers. DMS+ Data Management System MACOPRESS Smart provides full and intuitive data management. Separation programs can be customized directly from the tools menu. DMS+ enables the separator to be managed online and offers complete bi-directional process functionality. Computer connection can be with: • WiFi • ETHERNET • RS 485 (max 4 devices connected) DMS+ provides the following features: • Different preloaded languages • Compatible with Windows XP, Windows Vista, Windows 7. • Able to set all the machines at the same time or one by one • 30 barcodes/separation and filter mask for cross-matching and data control • Automatic Bidirectional controls. The program will be automatically chosen for each ID by comparing the data arriving from the external sources (balances, cells counter) with those selected through an applicable filters mask for parameters such as whole blood weights, donation time and/or cell counter data as PLTS, Hct, RBC... • For example: i. donation < 12 minutes, weight 450 ml +/- 10%, Hct > 40, PLTS > 180.000 OK = run PRG1 ii. donation > 12 minutes OK = run PRG2 iii. PLTS < 180.000 OK = run PRG3 … Traceability 21 parameters can be transmitted from MACOPRESS Smart to DMS+ for each separation. These fields can be fully managed by DMS+: Activation, modification of the sequence, saving route, formatting for any interfacing to management software that already exists. The data transmitted for each separation are: • Serial number of the MACOPRESS Smart • Description of the program • Net weight of each blood component, including whole blood • Date and time of separation; duration of the separation • Error code • Operator code ID1, ID2, ID3, ID4, parameters of centrifugation or barcode and classification of the result obtained... efficiency References (complete system with) • 9MPSBRLAN: Ethernet module (no breakers) • 9MPSBILAN: Ethernet module + Breaker N°1 integrated • 9MPSBRWIFI: WiFi module (no breakers) • 9MPSBIWIFI: WiFi module + Breaker N°1 integrated • 9MPSBR485: RS232-485 module (max 4 x MPS connected) (no breakers) • 9MPSBI485: RS232-485 module+ Breaker N°1 integrated Breaker option • 9MPSBRK01: Automatic cannula breaker module for main bag (N°1) • 9MPSBRK02: Automatic cannula breaker module for additive solution bag. Semi external device mounted on the additive solution scale • 9MPSBRK03: Automatic double cannula breaker module for red cell bag and red cell mixer. External device mounted beside the MPS Accessories and Options: Communication accessories (DMS+) • RS485 connection included with each MPS 9MPS070: RS485 cable 9MPS311: Network adapter (for each Computer) • for WiFi connection 9MPSWIFI: WiFi module (for each MPS) 9MPSWIFIAP: WiFi Access Point (for computer) • for ethernet connection (LAN) 9MPSLAN: Ethernet module (for each MPS) 9MPSLANCAB: Network ethernet cable (one for each MPS +one for the ethernet switch) 9MPSHUBPC: Ethernet switch (one per PC) each Accessories • 9MPS050: • 9MPS040: Additional Additional external balance sealing handle • 9MPS10012: Filter holder (small) •9 MPS10011: Filter holder (LCR5) •9 MPS095: Splash Guard Barcode reader The MACOPRESS Smart is CE certified, Class I MDD, 93/42/EEC. In compliance with : SAFETY: IEC/EN 60601-1, 3rd Ed. IEC/EN 61010-1, 2nd Ed. UL 61010-1 2nd Ed. CAN/CSA C22.2 No. 61010-1 +GI1 2nd Ed. IEC/EN 62304 1st Ed. EMC: IEC/EN 60601-1-2, 3rd Ed. IEC/EN 61326, 1st Ed. Please refer to the instructions for use MACO PHARMA Rue Lorthiois F-59420 Mouvaux (France) www.macopharma.com Distributed by: • RFID Reader: 9MPS080: CCD Combo Reader for barcode and reader/writer RFID 9MPS080L: Laser Combo Reader for barcode and reader/writer RFID XM4AA02D-May 2013 • Maco Scan QS i: 9MSC10014596. 9MSC1001462 (with support). 9MSC10014493 (Macoscan mobile+base)