next neXt close control air conditioners / heat pumps new cooling capacity compressors refrigerant fan type scroll R410A plug-fan / centrifugal microprocessorMP.COM RCGROUP SpA free-cooling yes C_GNR_0510 6,6 ÷ 104,0 kW 10 neXt close control air conditioners / heat pumps VERSIONS: new DX (R410A) - Plug Fan Cooling capacity 6,4 ÷ 97,6 kW Direct expansion air conditioner in Under and Over versions, for remote air cooled condenser matching. new DX.P (R410A) - Plug Fan Heat pump air conditioner in Over versions, for remote air cooled condenser matching. next UNDER new DW (R410A) - Plug Fan GENERAL FEATURES Direct expansion air conditioner in Under and Over versions, with built-in water cooled The NEXT series air conditioners are the best answer to condenser. the need of a precise control of the thermo-hygrometric and air purity conditions in the modern and sophisticated Hi-Tech installations and in the high quality “comfort” applications, granting the optimal environment for electronic equipment to work in and operators wealth. new DW.P (R410A) - Plug Fan Heat pump air conditioner in Over versions, with built-in water cooled condenser. Computer rooms, telephone exchanges, internet hotels, museums, shopping centres are just some of the typical applications of NEXT units, whose efficiency, silentness and versatility features are appreciated by the most qualified users worldwide. CW - Plug Fan HIGH DENSITY Cooling capacity 10,3 ÷ 104,4 kW Thanks to the layout optimization of components and Chilled water feeding air conditioner in Under accessories, the NEXT air conditioners can grant a high and Over versions. cooling density for those situations where the space organization becomes a key-factor same as the capacity. CW.K - Plug Fan Cooling capacity 13,1 ÷ 161,0 kW High density chilled water feeding air conditioner in Under and Over versions. CW.KC - Centrifugal fan Cooling capacity 13,1 ÷ 161,0 kW High density chilled water feeding air conditioner in Under and Over versions, with centrifugal C_GNR_0510 fans. RCGROUP SpA neXt 11 close control air conditioners / heat pumps NEXT air conditioners are available in Over and Under version. MAIN COMPONENTS Up-flow air delivery (Over) •Base and housing in epoxy painted aluminium The air distribution is from the top of the unit directly in to the room. The air flow in each area is predetermined during the profile frame and panels in galvanized steel sheet externally coated with PVC film. design stage and it is not dependent on the actual state •Plug fans of the load to be dissipated. The system is normally • Centrifugal fans (CW KC) applied in Comfort plants and in those plants having a defined low/medium room thermal loads density. • Scroll compressor (DX – DW) • Refrigerant circuit: single or double DC (DX-DW) Down-flow air delivery (Under) The air distribution is from the bottom by means of the plenum between the building floor and the raised floor. This solution is usually applied in Hi-Tech room air conditioning and it is most favourable when load is uniformly distributed in all areas of the room. • Cycle reversing valve (DX.P – DW.P) •3-way proportional cooling valve with emergency manual control (CW – CW.K) •Electrical box in separate compartment •Main switch with door lock safety •MP.COM microprocessor control MAIN OPTIONAL ACCESSORIES • Serial port • Remote air cooled condenser (DX - DX.P) •EC fans (electronically commutated) •Electric or hot water heating system •Humidification and dehumidification system • Compressor capacity control (DX – DW) •Free-cooling system (DW) •Plenum on air suction for direct free-cooling system •Extra-circuit system (DX – DW – CW) •Hot gas re-heating system (DX-DW) •Plenum on air delivery •High efficiency filters F5/F6/F7/F9 • Compressor cap for noise reduction next RCGROUP SpA C_GNR_0510 nexT OVER 12 neXt close control air conditioners / heat pumps TECHNICAL DATA AND NOMINAL PERFORMANCES new NEXT DX under/over - Plug fans MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (2) Over Under MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (2) Over Under MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (2) Over Under kW m3/h n. kg kg dB(A) dB(A) 006 008 010 007 009 011 013 014 015 017 019 021 023 025 029 033 P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S P1 S H0H0H0H1H1H1H1H2H2H2H3H3H3H4H4H4 6,4 7,58,9 7,18,2 9,5 10,8 11,8 14,1 16,4 17,1 19,2 21,2 24,5 27,332,3 1580 1800 2000 2273 2653 2653 2653395539553955 5460 5460 5460 7160 7440 7440 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 160 160 160 186 189 190 191 244 246 247303306307 421 421 422 160 160 160 192 196 197 198 254 256 258314317318 441 441 442 50,4 52,2 54,3 49,8 50,7 52,1 52,1 55,5 55,5 56,7 56,2 58,7 56,8 58,1 60,7 60,7 57,7 60,3 62,4 57,1 60,1 60,1 60,1 67,3 67,3 67,3 66,4 66,4 66,4 69,2 72,2 72,2 038 040 045 049 026 026 028 028 032 032 036 036 042 042 048 P1 S P1 S P1 S P1 S P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S H5H5H5H5H5H5H5H5H5H5H5H5H6H6H6 kW 34,137,8 40,8 47,9 23,3 23,5 29,8 29,732,432,438,238,2 40,3 40,3 45,8 m3/h 10440 10440 10440 10440 7110 7110 10440 10440 10440 10440 10440 10440 11310 11310 11310 1 1 1 2 2 2 2 2 2 2 2 2 2 2 n. 1 kg 476 476 476 484 455 455 457 457 457 457 kg 492 492 492 500 471 471 473 473 473 473 dB(A) 62,6 62,9 63,2 63,5 57,7 57,7 62,1 62,6 62,6 62,6 dB(A) 74,9 74,9 74,9 74,9 69,1 69,1 74,9 74,9 74,9 74,9 460 476 460 476 563 589 563 589 565 591 64,0 74,9 64,0 74,9 61,3 67,3 61,3 67,3 59,0 67,3 048 052 052 060 060 064 064 072 072 082 082 092 092 100 100 P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC P2 S P2 DC H6H6H6H6H6H6H6H7H7H7H7H7H7H7H7 kW 45,9 49,6 49,7 57,8 57,4 60,1 59,7 69,6 69,0 78,1 78,887,285,6 96,6 97,6 m3/h 11310 13480 13480 14500 14500 16000 16000 17610 17610 20870 20870 22040 22040 22040 22040 2 2 2 2 2 2 2 2 2 2 2 2 2 2 n. 2 kg 565 668 668 668 668 683 683 770 770 776 776 783 783812812 kg 591 694 694 694 694 709 70980380381080816816845845 dB(A) 59,0 60,3 60,3 62,2 62,2 63,8 63,8 62,5 62,5 65,9 65,9 67,5 67,5 67,7 67,7 dB(A) 67,3 70,8 70,8 72,5 72,5 75,4 75,4 73,1 73,1 77,9 77,9 79,7 79,7 79,7 79,7 S = Unit with single refrigerant circuit / DC = Unit with double refrigerant circuit (1) Referred to entering air at 24°C with 50%RH and air to the condenser at 35°C (2) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: 400.3.50+N OTHER VERSIONS AVAILABLE: DX O P : air cooled OVER units in Heat Pump version. DW: water cooled OVER and UNDER units. DW O P: water cooled OVER units in Heat Pump version. C_GNR_0510 air cooled condenser The DX and DX P series are planned for the matching to the TEAM MATE MR condenser series. RCGROUP SpA neXt 13 close control air conditioners / heat pumps TECHNICAL DATA AND NOMINAL PERFORMANCES NEXT CW under/over - Plug fans MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under kW m3/h 012 015 018 022 031 044 050 066 078 094 114 H1H2H2H3H4H5H5H6H6H7H8 10,3 14,5 17,2 22,0 29,639,9 47,1 59,5 74,689,4 104,0 265339553955 5460 7440 10440 10440 15060 14850 22040 29050 166 212 212 271337389389 kg 166 204 204 257326365365 kg 47,2 53,8 53,8 52,9 58,7 61,4 61,4 dB(A) 42,0 49,2 49,2 48,3 54,1 56,8 56,8 dB(A) 495 466 510 481 596 557 734 683 61,9 57,3 61,7 57,1 66,2 61,6 64,2 59,6 174 174 NEXT CW K under/over - Plug fans MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under 013 020 029 046 068 104 104 120 142 142 H1H2H3H4H5H6H6LH6H7H7LH8H8L 13,1 19,1 27,7 41,8 62,4 94,8 115,0 112,0 135,0 167,0 161,0 199,0 kW 26533870 54608460 12390 18600 23000 19040 25340310003010037500 m3/h 155 200 258330 430 550 -- 570 680 -- 780 -kg 172 211 268313 410 518 550 538 665 700 780800 kg 47,2 53,4 52,9 56,7 53,6 61,8 -- 63,1 61,4 -- 65,6 -dB(A) 42,6 49,2 49,4 52,1 49,0 57,2 57,4 58,5 56,8 55,9 61,0 58,8 dB(A) NEXT CW KC under/over - centrifugal fans MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under 006 013 020 029 046 068 104 120 142 174 H0H1H2H3H4H5H6H6H7H8 5,6 13,1 19,1 27,7 41,8 63,6 94,8 112,0 135,0 161,0 kW 1538 26533870 54608460 12390 18600 19040 2534030100 m3/h 120 160 210 270340 445 656 590 700800 kg 120 155 200 258330 430 550 570 680 780 kg 47,0 47,2 53,8 54,0 60,5 60,7 64,9 65,8 65,3 67,8 dB(A) 42,5 42,5 48,8 49,4 55,6 55,8 60,0 61,0 60,4 62,9 dB(A) RCGROUP SpA C_GNR_0510 (1) Referred to entering air at 24°C with 50%RH and chilled water temperature 7/12,5°C (2) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: size H0 230/1/50 POWER SUPPLY: 400.3.50+N 14 neXt close control air conditioners / heat pumps DIMENSIONS (mm) C_GNR_0510 Size a b c H0 655 420 1.680 H1 650 650 1.925 H2 785 650 1.925 H3 1.085 750 1.925 H4 1.320 860 1.980 H5 1.620 860 1.980 H6 2.155 860 1.980 H6L 2.155 930 1.980 H7 2.690 860 1.980 H7L 2.690 930 1.980 H8 3.225 860 1.980 H8L 3.225 930 1.980 c a b RCGROUP SpA 15 next M neXt MTR close control air conditioners FOR METROLOGY LAB new cooling capacity compressors refrigerant fan type 6,6 ÷ 15,3 kW scroll R407C plug-fan microprocessorMP.COM RCGROUP SpA C_GNR_0510 16 neXt mtr close control air conditioners for metrology lab VERSIONS: new DX (R407C) - Plug Fan Cooling capacity 6,6 ÷ 14,4 kW Direct expansion air conditioner in Over versions, for remote air cooled condenser matching. new DW (R407C) - Plug Fan Cooling capacity 7,0 ÷ 15,3 kW Direct expansion air conditioner in Over versions, with built-in water cooled condenser. next mtr GENERAL FEATURES NEXT MTR air conditioners are available in Over version. The NEXT MTR air conditioners form a range of machines Up-flow air delivery (Over) featuring advanced Hi-Tech characteristics, designed for The air distribution is from the top of the unit directly in to a variety of applications, subject to strict requirements the room. in terms of control of internal environmental conditions, The air flow in each area is predetermined during the continuous operation, reliability and energy saving. design stage and it is not dependent on the actual state of the load to be dissipated. The extreme precision of the MP.COM control system allows maintaining temperature and humidity conditions with a tolerance of ± 0.3°C and ± 3%rH. NEXT MTR is particularly suitable for installation in metrology labs, conservation labs and still in all those applications that require continuous and precise control of C_GNR_0510 temperature and humidity. NEXT MTR is equipped with Plug-fan next RCGROUP SpA neXt mtr 17 close control air conditioners for metrology lab MAIN COMPONENTS •Base and housing in epoxy painted aluminium profile frame and panels in galvanized steel sheet externally coated with PVC film. •Plug fan with EC motor • Scroll compressor •Electric heating system •Humidification and dehumidification system • Compressor capacity control •Hot gas re-heating system •Electrical box in separate compartment •Main switch with door lock safety •MP.COM microprocessor control MAIN OPTIONAL ACCESSORIES • Serial port • Remote air cooled condenser (DX) •Plenum on air delivery •High efficiency filters F5/F6/F7/F9 mtr RCGROUP SpA C_GNR_0510 • Compressor cap for noise reduction 18 neXt mtr close control air conditioners for metrology lab TECHNICAL DATA AND NOMINAL PERFORMANCES new NEXT MTR DX over - Plug fan MODEL Size Cooling capacity (1) Air flow Compressors Weight Sound pressure (3) new kW m3/h n. kg dB(A) 007 009 011 013 015 Z1 S Z1 S Z1 S Z1 S Z1 S H2H2H2H3H3 6,68,6 9,8 11,3 14,4 230030003300 4000 5500 1 1 1 1 1 54,4 54,8 55,1 55,9 57,1 NEXT MTR DW over - Plug fan MODEL Size Cooling capacity (2) Air flow Compressors Weight Sound pressure (3) kW m3/h n. kg dB(A) 007 009 011 013 015 Z1 S Z1 S Z1 S Z1 S Z1 S H2H2H2H3H3 7,08,9 10,3 12,3 15,3 230030003300 4000 5500 1 1 1 1 1 54,4 54,8 55,1 55,9 57,1 (1) Referred to entering air at 24°C with 50% RH and outdoor air temperature at 35°C. (2) Referred to entering air at 24°C with 50% RH and water inlet to the condenser 30/36°C. (4) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: 400.3.50+N air cooled condenser The DX series is planned for the matching to the TEAM MATE MR condenser series. DIMENSIONS (mm) Size a b c H2 785 650 1.925 H3 1.085 750 1.925 c C_GNR_0510 a b RCGROUP SpA