GAS-FIRED RADIANT HEATER ® PRICE SHEET FOR MODEL VP CONTRACT PLAN PRODUCT Remove and Destroy Price Sheet $-VP FORM $-VP (Version A) EFFECTIVE JUNE 2, 2013 SHIPMENT, TITLE, AND RISK OF LOSS All prices quoted are FOB shipping point. Prices applicable to continental U.S.A. and Canada (payable in U.S. funds). All prices subject to change without notice. Terms of Sales for all Purchase Orders are outlined in the Distributor contracts for these products. If you would like a copy, call (800) 695-1901. NOTE: Manufacturer reserves the right to add components (at net prices) when necessary to obtain the operation desired by the customer. KEY: Base price includes all items listed as standard (STD); - indicates no change in price; ■ indicates not available. VP SER SERIES - POSITIVE PRESSURE, C Factory Installed Options Options listed in Reverse Type 60 AA1 - Size FUEL TYPE Natural gas Propane (See Opt DL2 for field conversion) SUPPLY VOLTAGE 115/1/60 208/1/60 (Option AK2) 230/1/60 (Option AK3) 220/240/1/50 (Option AK11) 80 80 $866 29 $971 34 100 100 $866 29 $971 34 125 125 $866 29 $971 34 150 150 $866 29 $971 34 Must be selected 80 100 125 - 150 - Size 170 200 170 200 $866 $1,068 29 29 $1,173 $1,173 34 34 170 - 200 - - - Call for Quote SPEC AK1 SPEC SPEC SPEC M NT Y UA E RO LITY SYST A DU CT WARR P Model VPT 60 60 Positive Pressure, Single-Stage Heating $866 Ship Weight (lbs.) 29 Positive Pressure, 2-Stage Heating $971 Ship Weight (lbs.) 34 T CQS Q CUS MER TO Size MBH Input Model VPS RADIANT HEATERS - Model VP P C Y ROC EN E R G ES V EN ON START-UP G S A GAS-FIRED, TUBULAR, INFRARED HEATER - - - - - Call for Quote 60 80 100 125 150 170 200 60 80 100 125 150 170 200 DL2 $29 $29 $29 $29 $29 $29 $29 DE1 $79 $79 $79 $79 $79 $79 $79 DJ20 $21 $21 $21 $21 $21 $21 $21 60 80 100 125 150 170 200 Field Installed Options Size PROPANE CONVERSION KIT A B COMBUSTION AIR INLET ADAPTER ELEVATION ADAPTER KIT B Size A For field conversion of natural gas units to propane Combustion air inlet adapter for VPS only (STD on VPT) For installation over 2,000 ft above sea level - U.S Only When field converting size 170 (170 MBH) from natural gas to propane, the heater is reduced to 150 MBH. When field converting size 200 (200 MBH) from natural gas to propane, the heater is reduced to 170 MBH - does NOT apply to units installed at high altitude. B For higher elevation installation in Canada, please refer to the installation manual. Propane conversion kit includes high elevation adapter kit. Separate high elevation adapter kit is NOT required for units to be converted for use with propane. GAS FIRED RADIANT HEATER PRICE SHEET FORM NUMBER: $-VP Page 1 Section 42.1 Field Installed Options 20 ft system (1 Calcoat, 1 rolled steel tube) VP TUBE PACKAGES 30 ft system (1 Calcoat, 2 rolled steel tube) Calcoat and Rolled 30 ft system (2 Calcoat, 1 rolled steel Steel tube) Additional 20 ft sections (rolled steel) Tube Packages may alternately be ordered Additional 30 ft sections (rolled steel) as Model VP or VC 5 ft tube (rolled steel) “U” shaped tube (rolled steel) “L” shaped tube (rolled steel) 20 ft system (stainless steel) 30 ft system (stainless steel) VC TUBE PACKAGES 5 ft tube (stainless steel) Stainless Steel “U” shaped tube (stainless steel) “L” shaped tube (stainless steel) VPA $544 VPB $738 VPC $758 VPD VPE VPH VPU VPL $408 $612 $141 $153 $104 VCAS VCBS VCHS VCUS VCLS $591 $887 $167 $402 $224 Burner insert installs in first tube next to HDT5 $60 burner box - 5 ft (1,524mm) Turbulator strip installs at end of tube HDT6 $35 system - 4 ft, 3 in (1,277mm) Turbulator strip installs at end of tube HDT7 $23 system - 8 ft, 6 in (2,600mm) Standard vent cap CC1 $71 VENT CAP Stainless steel vent cap CC21 $131 Two reflector end caps CD27 $26 REFLECTOR END CAP C Two stainless steel reflector end caps CD37 $78 Manual shutoff valve and union - 3/4” CE2 $62 MANUAL VALVES Stainless steel flexible gas connector CE4 $137 (U.S. only), 36” - 3/4” ID D 24-volt single-stage, 50°-90°F CL1 $79 Two-stage thermostat CL22 $151 THERMOSTAT Single-stage line voltage thermostat CL5C $53 Thermostat guard with locking cover CM1 $67 Chain (50 ft) and 11 “S” Hooks CK11 $130 HANGER KIT Chain (50 ft) and 11 “S” Hooks - stainless CK31 $502 steel System Configuration Tube Length Straight “U” or “L” 20 ft CK12 $99 CK13 $111 30 ft CK13 $111 CK14 $122 Steel 40 ft CK14 $122 CK15 $134 TURNBUCKLE KITS 50 ft CK15 $134 CK16 $138 60 ft CK16 $138 CK17 $149 To facilitate leveling 70 ft CK17 $149 CK18 $160 80 ft CK28 $160 CK29 $170 One Turnbuckle per Suspension Point. System Configuration Tube Length Turnbuckle kits do not Straight “U” or “L” include chain or “S” 20 ft CK32 $243 CK33 $290 hooks (Option CK11 or 30 ft CK33 $290 CK34 $336 CK31) Stainless Steel 40 ft CK34 $336 CK35 $378 50 ft CK35 $378 CK36 $420 60 ft CK36 $420 CK37 $459 $497 70 ft CK37 $459 CK38 80 ft CK39 $497 CK40 $535 BURNER INSERT AND TURBULATORS (Required on some sizes, see chart below) F BURNER INSERT / TURBULATOR SELECTION GUIDE Fuel Size Length Layout HDT5 HDT6 20 Straight 80 30 Straight 40 Straight Natural Gas 30 Straight 100 40 Straight SingleStage 50 Straight - VPS 60 20 Straight Propane 80 20 Straight 20 U Bend 80 Natural 40 U Bend Gas 100 40 U Bend 20 Straight 60 30 Straight 40 Straight 30 Straight 80 Natural 40 Straight Gas 30 Straight 100 40 Straight 125 30 Straight TwoStage 150 40 Straight - VPT 60 20 Straight 100 30 Straight Propane 125 30 Straight 150 40 Straight 20 U Bend 60 40 U Bend Natural Gas 80 40 U Bend 100 40 U Bend Model C D F Size 60 80 100 125 150 170 200 Page 2 Pressure Drop (inches w.c.) 0.05 0.05 0.10 0.15 0.20 0.40 0.50 Gas Pressure Required at the Gas Valve Natural Gas Propane Gas Maximum Minimum Maximum Minimum G 5 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 5 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 5 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 5 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 5 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 7 in. w.c. 14 in. w.c. 11 in. w. c. 14 in. w.c. 7 in. w.c. 14 in. w.c. G HDT7 Optional end caps can be attached to reflectors at beginning and end of system length. Two end caps can also be attached instead of corner reflector(s) for End Cap “L” or “U” tubes. See image below. Refer to installation manual for attaching end caps to reflectors. The table (bottom) shows gas pressure drop through the flexible connector. Supply line pressure minus the pressure drop equals actual pressure at the gas valve. Minimum required pressure must be maintained at the gas valve. Burner insert or turbulator strips are REQUIRED on specific heating size/length combinations. Using burner insert or turbulator strip will increase efficiency of heater. Failure to use these where listed will void warranty. See Selection Guide to the right. Minimum natural gas pressure shown for Model VPS. Model VPT (two-stage heater) requires 7 in. w.c. minimum gas pressure for all sizes when used with natural gas. GAS FIRED RADIANT HEATER PRICE SHEET FORM NUMBER: $-VP TUBE PACKAGE ASSEMBLY CONTENTS When ordering a tube package for Model VPS or VPT, specify complete model: i.e. VP-A for a 20 foot long section of tubes (one Calcoat and one rolled steel). For stainless steel tube assemblies, specify Model VC-_. See selection matrix on next page. Ship Weight (lbs.) 10 foot Calcoat™ combustion chamber 10 foot rolled steel heat exchanger(s) 5 foot rolled steel heat exchanger Rolled steel “U” tube Rolled steel “L” tube 10 foot reflectors 5 foot reflector Corner reflector(s) Tube coupler(s) Suspension bracket(s) Reflector support bracket assembly(ies) Model VCTube Packages Ship Weight (lbs.) 10 foot stainless steel tube(s) 5 foot stainless steel heat exchanger Stainless steel “U” tube Stainless steel “L” tube 10 foot stainless steel reflectors 5 stainless steel foot reflector Stainless steel corner reflector(s) Stainless steel tube coupler(s) Stainless steel suspension bracket(s) Stainless steel reflector support bracket assembly(ies) A $544 26 1 1 2 1 2 2 B $738 39 1 2 3 2 3 3 C $758 39 2 1 3 2 3 3 D $408 26 2 2 2 2 2 E $612 39 3 3 3 3 3 AS $591 29 2 2 2 2 2 BS $887 44 3 3 3 3 3 HS $167 10 1 1 1 1 1 US $402 17 1 2 1 1 1 LS $224 10 1 1 1 1 - H $141 7 1 1 1 1 1 U $153 13 1 2 1 1 1 L $104 10 1 1 1 1 - RADIANT HEATERS - Model VP Model VPTube Packages HEATER CONFIGURATIONS The following sketches represent various ways Reznor tubular, radiant heaters may be configured. It is important to follow the limitations listed in the note section below. For more configuration help, contact your Reznor Agent. 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 60 ft. 70 ft. 80 ft. NOTE: ● The minimum length allowed is 20 ft. The maximum length allowed is 80 ft. A five foot tube section (package -H or -HS) can be added for lengths between 25 and 75 ft. Total tube system lengths of 15 ft and 85 ft. are NOT allowed. ● “U” and “L” tubes must be installed AT or AFTER the halfway length of the tube system. For example: on a 60 ft. system, the “U” or “L” tube must be installed at least 30 ft. from the burner box. ● Limited number of bends » Maximum two “L” tubes may be used in a single system » Maximum one “U” tube may be used in a single system » Maximum one “U” tube AND one “L” tube may be used ONLY if the “L” tube is the last section in the system GAS FIRED RADIANT HEATER PRICE SHEET FORM NUMBER: $-VP Page 3 Section 42.3 TUBE PACKAGE SELECTION MATRIX To order modular components for easy stocking or replacement of lost/damaged components select burner boxes and tube packages individually. Tube packages can be ordered by model numbers or part numbers. The table below shows which tube packages should be ordered for various system lengths. Please contact your Reznor Representative for assistance. Note: Sizes 170 & 200 units require two Calcoat™ tubes. Single-Stage 20 30 60 VP-A VP-B VP-A and VP-D 80 VP-A VP-B VP-A and VP-D 50 60 70 80 60 VP-B VP-A and VP-D 80 VP-B VP-A and VP-D 100 VP-B VP-A and VP-D 50 125 VP-B VP-A and VP-D VP-A and VP-E 60 150 VP-A and VP-D VP-A and VP-E VP-B and VP-E 70 60 VC-AS VC-BS (2) VC-AS 80 VC-AS VC-BS (2) VC-AS 50 60 100 VC-BS (2) VC-AS VC-AS and VC-BS 125 (2) VC-AS VC-AS and VC-BS (2) VC-BS 70 150 (2) VC-AS VC-AS and VC-BS (2) VC-BS (2) VC-AS and VC-BS 80 60 VC-BS (2) VC-AS 80 VC-BS (2) VC-AS 100 VC-BS (2) VC-AS 50 60 125 VC-BS (2) VC-AS VC-AS and VC-BS 150 (2) VC-AS VC-AS and VC-BS (2) VC-BS 70 System Length (ft) 40 System Length (ft) 2-Stage 30 40 System Length (ft) (Stainless Steel) Single-Stage 20 30 40 System Length (ft) (Stainless Steel) 2-Stage 30 40 100 VP-B VP-A and VP-D VP-A and VP-E 125 VP-A and VP-D VP-A and VP-E VP-B and VP-E 150 VP-A and VP-D VP-A and VP-E VP-B and VP-E VP-B and (2) VP-D 170 200 U VP-U VP-U L VP-L VP-L VP-U VP-L VP-C and VP-D VP-C and VP-E VP-C and (2) VP-D VP-C, VP-D and VP-E VP-C and VP-D VP-C and VP-E VP-C and (2) VP-D VP-C, VP-D and VP-E VP-U VP-L VP-U VP-L VP-U VP-L VP-U VP-L 170 200 U VP-U L VP-L VP-U VP-L VP-C and VP-D VP-C and VP-E VP-C and (2) VP-D VP-C and VP-D VP-C and VP-E VP-C and (2) VP-D VP-U VP-L VP-U VP-L VP-U VP-L 170 VC-AS and VC-BS (2) VC-BS (2) VC-AS and VC-BS VC-AS and (2) VC-BS 200 VC-AS and VC-BS (2) VC-BS (2) VC-AS and VC-BS VC-AS and (2) VC-BS U-S VC-US VC-US VC-US L-S VC-LS VC-LS VC-LS VC-US VC-LS VC-US VC-LS VC-US VC-LS VC-US VC-LS 170 VC-AS and VC-BS (2) VC-BS (2) VC-AS and VC-BS 200 VC-AS and VC-BS (2) VC-BS (2) VC-AS and VC-BS U-S VC-US VC-US L-S VC-LS VC-LS VC-US VC-LS VC-US VC-LS VC-US VC-LS NOTE: The minimum and maximum length are shown for each burner box. A five ft. tube section (package -H or -HS) can be added for system lengths between the minimum and maximum length. Example: Model VPS-100 can be used with 35 or 45 ft. tube system lengths. It can NOT be used for 25 or 55 ft. lengths. www.RezSpec.com Reznor and Calcoat are registered in at least The United States. © 2013 Thomas & Betts Corporation. All rights Reserved. Printed in U.S.A. 0813 OG POD Form $-VP (Version A) Page 4 GAS FIRED RADIANT HEATER PRICE SHEET FORM NUMBER: $-VP