EDI MVP 6/12 Dimmer Panel User Manual Click here

advertisement
MVP 6/12 Pak Dimmer
USERS MANUAL
Revision 3, January 2004
©2004 Electronics Diversified, Inc.
070-0829-03
Introduction
Description
This Manual is supplied with your MVP Dimmer System.
Copies of this manual may be obtained through EDI’s website for no charge. If a hard copy is needed, it can be obtained from the factory for a nominal charge.
No part of this Manual may be reproduced by any means,
graphic, electronic, or mechanical, including photocopying,
recording, taping, or information storage and retrieval systems, without the express written permission of Electronics
Diversified, Inc., except in connection with installation, repair
and maintenance of installed MVP Dimmer Systems.
The MVP is a simple compact dimming system. The MVP
is available in eight different standard configurations depending on power load per dimmer and number of dimmers. Options such as fluorescent dimming modules and
various dimming loads on dimmers may be featured on
custom units. Typically, The MVP unit will have either six
or twelve dimmers, denoted as MVP 6 or MVP 12. Dimmer modules may be 600W, 1.2kW, 1.8kW, and 2.4kW.
The MVP comes standard with a digital card accepting
DMX-512 protocol. In addition, the MVP has assignable
worklights and panic functions that can be remotely activated over 1000 feet of cable.
Table of Contents
The optional analog card accepts analog 0 –10 V signals
along with expansion cards. Two expansion slots allow
the user to add DMX-512, Worklight card, Set and Forget,
and other optional controller cards. The user can also add
secondary analog for a backup source if necessary in a
HTP scenario.
Introduction……………………………………………………. 1
Description…………………………………………………….. 1
Features……………………………………………………….. 2
Setup:
Precautions………………...................................
Power Up…………………………………………..
Control Sources…………………………………...
DMX………………………………………………...
Analog……………………………………………...
Panic………………………………………………..
Worklight…………………………………………...
3
3
3
4
5
5
5
Troubleshooting………………………………………………. 6
Service ………………………………………………………… 7
Registration……………………………………………………. 8
1
Features
Circuit Breakers
For Circuit Breakers
turn to page 3
Heat Vents
For Precautions,
turn to page 3
Heat Sinks
For Precautions,
turn to page 3
For Panic
Functions
turn to
page 5
Panic On
Power
Indicator Indicator
Over Temperature
Indicator
DMX In
Indicator
Worklight
On Indicator
For DMX
turn to
page 4
For Worklight
Functions turn
to page 5
Phase Indicator
Lights
For Phase
Indicators,
turn to
page 3
2
Setup
Precautions
Make sure to read the manual thoroughly before using the
MVP Dimmer.
WARNING: Make sure area is cleared
around the MVP. No flammable objects
should be placed near the heat sinks. No
object should be near or covering any of
the heat vents. Sporadic operation or possible fire may occur.
(A) MVP breakers (may vary in numbers and style )
600W versions
Power Up
1.2kW and 2.4kW versions
1.
2.
(B) Power indicator
Turn on main power to the MVP Dimmer Pack.
Turn on breakers on the MVP (Figure A). Make sure
all control sources are at their lowest level or off.
NOTE: 600 W MVP come with breakers in their on
position.
When the Main Feed is energized, The Power indicator
(Figure B) at the bottom of the box lights, displaying that
the control section of the rack and dimmers are powered.
Depending on the configuration, all three of the Phase
indicators (Figure C) are brightly lit. This represents normal operation. If one or more are dimly lit, refer to the
Trouble Shooting section (page 6). The Rack is now powered up.
(C) Phase indicators
Control Sources
The MVP is designed to handle a multitude of sources.
Depending on the unit designed, it may accept a DMX,
analog 0 to 10V, contact closures, or available controller
interface cards. The following sections explain how to set
up MVPs that accept analog and DMX sources. For more
information about other sources, please contact the factory.
3
Setup
(E) DMX Indicator
(D) DMX Card
DMX
If your MVP is being controlled by a USITT DMX-512
source, read the following instructions on how to
address the dimmer:
1.
2.
3.
S2
S1
Dimmer Addressing
Switches (HEX)
4.
5.
Unscrew the access panel at the bottom of the unit.
Locate the two DMX hex address switches (S1 and
S2) (Figure D).
Select a proper starting address for the dimmer using the guide below (Figure F) and assign the dimmer using the two address switches (S1 and S2). If
DMX is being accepted by the dimmer, the “DMX IN”
light (Figure E) should be lit.
Test lights at the DMX controller (SMART, TSC, etc.)
for proper function.
Replace access panel on dimmer.
(F) DMX address guide
S1 S2
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
addr.
off
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
S1 S2
addr.
S1 S2
addr.
S1 S2
addr.
S1 S2
addr.
S1 S2
addr.
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
85
87
89
91
93
95
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
129
131
133
135
137
139
141
143
145
147
149
151
153
155
157
159
161
163
165
167
169
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
171
173
175
177
179
181
183
185
187
189
191
193
195
197
199
201
203
205
207
209
211
213
215
217
219
221
223
225
227
229
231
233
235
237
239
241
243
245
247
249
251
253
255
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
257
259
261
263
265
267
269
271
273
275
277
279
281
283
285
287
289
291
293
295
297
299
301
303
305
307
309
311
313
315
317
319
321
323
325
327
329
331
333
335
337
339
341
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
343
345
347
349
351
353
355
357
359
361
363
365
367
369
371
373
375
377
379
381
383
385
387
389
391
393
395
397
399
401
403
405
407
409
411
413
415
417
419
421
423
425
427
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
429
431
433
435
437
439
441
443
445
447
449
451
453
455
457
459
461
463
465
467
469
471
473
475
477
479
481
483
485
487
489
491
493
495
497
499
501
503
505
507
509
4
Setup
Analog
If your MVP is being controlled by an analog source, the
contractor has wired specific outputs to a specific control
unit. Please contact your factory representative for more
details concerning the readdressing of the dimmer to a
different source input.
Panic
(G) One screw front panel
The MVP dimmer is equipped with a Panic function.
When activated, all dimmers go to full load. This feature is
useful in troubleshooting and bringing all lights on. To turn
on:
(H) Panic and Worklight
1.
2.
3.
Unscrew the front panel (Figure G).
Locate the Panic switch (Figure H).
Toggle Panic switch to the “On” position (Figure I).
When activated, the Panic light will turn on.
Depending on the installation, The MVP may be equipped
with a remote Panic switch. Consult your representative
for more details.
Panic and Worklight switches
Worklights
(I) Worklight Assignment
TEMINATION
RESISTOR
SWITCH
UNUSED
WORKLIGHT
ASSIGN 0N FOR
WORKLIGHT DIMMERS 1-6
SWITCH
PANIC
SWITCH
The MVP is also equipped with a Worklight function. This
function allows the user to easily bring on a specific set of
lights manually from the dimmer to full.
WORKLIGHT
ASSIGN 0N FOR
DIMMERS 7-12
(12 Pak Only)
1 2 3 4
5
To set and turn on the Worklights:
1. Unscrew the front panel (Figure G).
2. Locate and select the correct Worklight assigned
dimmer switches using the diagram (Figure I).
3. Push the Worklight assigned dimmer switch to the
“On” position.
4. Push the Worklight Switch and the light for the dimmer(s) should light up.
Troubleshooting
Symptom
Indicators
Causes
Remedy
System dead, no
lights come on,
regardless of
controller
settings.
No indicators are lit.
Unit is not powered.
Find main circuit breakers to
MVP
DMX indicator is not lit.
Control source is not
talking to the dimmers.
Check to see if control
source is on or
improperly working.
All correct lights are lit
Dimmer Breakers are
off.
Turn on circuit breakers
Analog source is not
talking to the dimmer.
Check to see if control
source is on or
improperly working.
Control board
malfunctioning
Call service technician
A phase is out.
Check main circuit
breakers to MVP.
Wiring is not
connected securely or
is improperly wired.
Call service technician.
Analog source is not
properly connected to the
dimmer.
Check to see if control
source is on or
improperly working.
Control board
malfunctioning or
blown SCR
Call service technician
Some lights come
on, but one or
more will not.
One or more phase
lights are dimly lit.
All correct lights are lit
Lights are on but
cannot be controlled by the
source
Panic indicator is lit
Panic is on and
overriding the control
source.
Turn off Panic.
Some lights are
on but cannot be
dimmed.
Worklight indicator
is lit.
Worklight is on
Turn off Worklight.
Lights will go out
and come back on
after some time
Overtemp indicator
lights as the unit shuts
The unit is
overheating.
Shut down and remove
any obstructions from off.
the front of the unit. If the
problem persists contact
the factory.
6
Service
EDI offers a 24 hour Service/Support Network.
For technical questions about this product or operational assistance, ask for Customer
Service at:
Telephone:………………………………………………………………….1-800-547-2690
FAX:………………………………………………………………………...1-503-629-9877
Internet…………………………………………………………………..www.edionline.com
Internet E-Mail:…………………………………………………….service@edionline.com
If your MVP needs repair, call: 1-503-645-5533 for a Return Materials Authorization number. A shipping address will be furnished.
This dimmer is a product of:
1675 N.W. Cornelius Pass Road, Hillsboro, Oregon 97214 USA
7
MVP
Attention MVP Owners!
Please return this registration card immediately.
Your prompt attention to this matter will ensure your receiving updated technical information for this product as it becomes available.
Please complete all information. Look for acknowledgement of your
registration within 6-8 weeks.
Name: _________________________________________________
Title: ___________________________________________________
Activation Date: __________________________________________
Facility and/or Company: ___________________________________
_______________________________________________________
Street Address: __________________________________________
_______________________________________________________
City: _________________
State: ________ Zip: _____________
CUT ALONG DOTTED LINE
Phone: _________________________________________________
Fax: ___________________________________________________
E-mail: _________________________________________________
Web site: _______________________________________________
Mail To:
EDI User Manual Registration
1675 NW Cornelius Pass Road
Hillsboro, Oregon 97214
or FAX to: (503) 629-9877
8
Download