MVP 6/12 Pak Dimmer USERS MANUAL Revision 3, January 2004 ©2004 Electronics Diversified, Inc. 070-0829-03 Introduction Description This Manual is supplied with your MVP Dimmer System. Copies of this manual may be obtained through EDI’s website for no charge. If a hard copy is needed, it can be obtained from the factory for a nominal charge. No part of this Manual may be reproduced by any means, graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems, without the express written permission of Electronics Diversified, Inc., except in connection with installation, repair and maintenance of installed MVP Dimmer Systems. The MVP is a simple compact dimming system. The MVP is available in eight different standard configurations depending on power load per dimmer and number of dimmers. Options such as fluorescent dimming modules and various dimming loads on dimmers may be featured on custom units. Typically, The MVP unit will have either six or twelve dimmers, denoted as MVP 6 or MVP 12. Dimmer modules may be 600W, 1.2kW, 1.8kW, and 2.4kW. The MVP comes standard with a digital card accepting DMX-512 protocol. In addition, the MVP has assignable worklights and panic functions that can be remotely activated over 1000 feet of cable. Table of Contents The optional analog card accepts analog 0 –10 V signals along with expansion cards. Two expansion slots allow the user to add DMX-512, Worklight card, Set and Forget, and other optional controller cards. The user can also add secondary analog for a backup source if necessary in a HTP scenario. Introduction……………………………………………………. 1 Description…………………………………………………….. 1 Features……………………………………………………….. 2 Setup: Precautions………………................................... Power Up………………………………………….. Control Sources…………………………………... DMX………………………………………………... Analog……………………………………………... Panic……………………………………………….. Worklight…………………………………………... 3 3 3 4 5 5 5 Troubleshooting………………………………………………. 6 Service ………………………………………………………… 7 Registration……………………………………………………. 8 1 Features Circuit Breakers For Circuit Breakers turn to page 3 Heat Vents For Precautions, turn to page 3 Heat Sinks For Precautions, turn to page 3 For Panic Functions turn to page 5 Panic On Power Indicator Indicator Over Temperature Indicator DMX In Indicator Worklight On Indicator For DMX turn to page 4 For Worklight Functions turn to page 5 Phase Indicator Lights For Phase Indicators, turn to page 3 2 Setup Precautions Make sure to read the manual thoroughly before using the MVP Dimmer. WARNING: Make sure area is cleared around the MVP. No flammable objects should be placed near the heat sinks. No object should be near or covering any of the heat vents. Sporadic operation or possible fire may occur. (A) MVP breakers (may vary in numbers and style ) 600W versions Power Up 1.2kW and 2.4kW versions 1. 2. (B) Power indicator Turn on main power to the MVP Dimmer Pack. Turn on breakers on the MVP (Figure A). Make sure all control sources are at their lowest level or off. NOTE: 600 W MVP come with breakers in their on position. When the Main Feed is energized, The Power indicator (Figure B) at the bottom of the box lights, displaying that the control section of the rack and dimmers are powered. Depending on the configuration, all three of the Phase indicators (Figure C) are brightly lit. This represents normal operation. If one or more are dimly lit, refer to the Trouble Shooting section (page 6). The Rack is now powered up. (C) Phase indicators Control Sources The MVP is designed to handle a multitude of sources. Depending on the unit designed, it may accept a DMX, analog 0 to 10V, contact closures, or available controller interface cards. The following sections explain how to set up MVPs that accept analog and DMX sources. For more information about other sources, please contact the factory. 3 Setup (E) DMX Indicator (D) DMX Card DMX If your MVP is being controlled by a USITT DMX-512 source, read the following instructions on how to address the dimmer: 1. 2. 3. S2 S1 Dimmer Addressing Switches (HEX) 4. 5. Unscrew the access panel at the bottom of the unit. Locate the two DMX hex address switches (S1 and S2) (Figure D). Select a proper starting address for the dimmer using the guide below (Figure F) and assign the dimmer using the two address switches (S1 and S2). If DMX is being accepted by the dimmer, the “DMX IN” light (Figure E) should be lit. Test lights at the DMX controller (SMART, TSC, etc.) for proper function. Replace access panel on dimmer. (F) DMX address guide S1 S2 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A addr. off 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 S1 S2 addr. S1 S2 addr. S1 S2 addr. S1 S2 addr. S1 S2 addr. 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 85 87 89 91 93 95 97 99 101 103 105 107 109 111 113 115 117 119 121 123 125 127 129 131 133 135 137 139 141 143 145 147 149 151 153 155 157 159 161 163 165 167 169 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F 80 171 173 175 177 179 181 183 185 187 189 191 193 195 197 199 201 203 205 207 209 211 213 215 217 219 221 223 225 227 229 231 233 235 237 239 241 243 245 247 249 251 253 255 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB 257 259 261 263 265 267 269 271 273 275 277 279 281 283 285 287 289 291 293 295 297 299 301 303 305 307 309 311 313 315 317 319 321 323 325 327 329 331 333 335 337 339 341 AC AD AE AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5 D6 343 345 347 349 351 353 355 357 359 361 363 365 367 369 371 373 375 377 379 381 383 385 387 389 391 393 395 397 399 401 403 405 407 409 411 413 415 417 419 421 423 425 427 D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF 429 431 433 435 437 439 441 443 445 447 449 451 453 455 457 459 461 463 465 467 469 471 473 475 477 479 481 483 485 487 489 491 493 495 497 499 501 503 505 507 509 4 Setup Analog If your MVP is being controlled by an analog source, the contractor has wired specific outputs to a specific control unit. Please contact your factory representative for more details concerning the readdressing of the dimmer to a different source input. Panic (G) One screw front panel The MVP dimmer is equipped with a Panic function. When activated, all dimmers go to full load. This feature is useful in troubleshooting and bringing all lights on. To turn on: (H) Panic and Worklight 1. 2. 3. Unscrew the front panel (Figure G). Locate the Panic switch (Figure H). Toggle Panic switch to the “On” position (Figure I). When activated, the Panic light will turn on. Depending on the installation, The MVP may be equipped with a remote Panic switch. Consult your representative for more details. Panic and Worklight switches Worklights (I) Worklight Assignment TEMINATION RESISTOR SWITCH UNUSED WORKLIGHT ASSIGN 0N FOR WORKLIGHT DIMMERS 1-6 SWITCH PANIC SWITCH The MVP is also equipped with a Worklight function. This function allows the user to easily bring on a specific set of lights manually from the dimmer to full. WORKLIGHT ASSIGN 0N FOR DIMMERS 7-12 (12 Pak Only) 1 2 3 4 5 To set and turn on the Worklights: 1. Unscrew the front panel (Figure G). 2. Locate and select the correct Worklight assigned dimmer switches using the diagram (Figure I). 3. Push the Worklight assigned dimmer switch to the “On” position. 4. Push the Worklight Switch and the light for the dimmer(s) should light up. Troubleshooting Symptom Indicators Causes Remedy System dead, no lights come on, regardless of controller settings. No indicators are lit. Unit is not powered. Find main circuit breakers to MVP DMX indicator is not lit. Control source is not talking to the dimmers. Check to see if control source is on or improperly working. All correct lights are lit Dimmer Breakers are off. Turn on circuit breakers Analog source is not talking to the dimmer. Check to see if control source is on or improperly working. Control board malfunctioning Call service technician A phase is out. Check main circuit breakers to MVP. Wiring is not connected securely or is improperly wired. Call service technician. Analog source is not properly connected to the dimmer. Check to see if control source is on or improperly working. Control board malfunctioning or blown SCR Call service technician Some lights come on, but one or more will not. One or more phase lights are dimly lit. All correct lights are lit Lights are on but cannot be controlled by the source Panic indicator is lit Panic is on and overriding the control source. Turn off Panic. Some lights are on but cannot be dimmed. Worklight indicator is lit. Worklight is on Turn off Worklight. Lights will go out and come back on after some time Overtemp indicator lights as the unit shuts The unit is overheating. Shut down and remove any obstructions from off. the front of the unit. If the problem persists contact the factory. 6 Service EDI offers a 24 hour Service/Support Network. For technical questions about this product or operational assistance, ask for Customer Service at: Telephone:………………………………………………………………….1-800-547-2690 FAX:………………………………………………………………………...1-503-629-9877 Internet…………………………………………………………………..www.edionline.com Internet E-Mail:…………………………………………………….service@edionline.com If your MVP needs repair, call: 1-503-645-5533 for a Return Materials Authorization number. A shipping address will be furnished. This dimmer is a product of: 1675 N.W. Cornelius Pass Road, Hillsboro, Oregon 97214 USA 7 MVP Attention MVP Owners! Please return this registration card immediately. Your prompt attention to this matter will ensure your receiving updated technical information for this product as it becomes available. Please complete all information. Look for acknowledgement of your registration within 6-8 weeks. Name: _________________________________________________ Title: ___________________________________________________ Activation Date: __________________________________________ Facility and/or Company: ___________________________________ _______________________________________________________ Street Address: __________________________________________ _______________________________________________________ City: _________________ State: ________ Zip: _____________ CUT ALONG DOTTED LINE Phone: _________________________________________________ Fax: ___________________________________________________ E-mail: _________________________________________________ Web site: _______________________________________________ Mail To: EDI User Manual Registration 1675 NW Cornelius Pass Road Hillsboro, Oregon 97214 or FAX to: (503) 629-9877 8