F Din Rail Snap/Surface-Mount Sockets • SU Series . . . . . . . . . . . . . . . . . . . ..F-6 New • SJ Series . . . . . . . . . . . . . . . . . . . . ..F-9 New • SQ Series . . . . . . . . . . . . . . . . . . . F-10 • SR Series . . . . . . . . . . . . . . . . . . . F-11 • SH Series . . . . . . . . . . . . . . . . . . . F-14 • SY Series . . . . . . . . . . . . . . . . . . . F-18 • SM Series . . . . . . . . . . . . . . . . . . . F-20 Sockets Section Selection Guide.................................. F-2 Through Panel Mount Sockets • SR Series . . . . . . . . . . . . . . . . . . . F-21 • SH Series . . . . . . . . . . . . . . . . . . . F-22 • SY Series . . . . . . . . . . . . . . . . . . . F-24 PCB Mount Sockets • SH Series . . . . . . . . . . . . . . . . . . . F-25 • SY Series . . . . . . . . . . . . . . . . . . . F-26 Panel Mounted Sockets for Timers • SR Series . . . . . . . . . . . . . . . . . . . F-28 Accessories ....................................... F-29 Dimensions....................................... F-31 for more information on this product family visit Additional Web Resources • New and updated product information • Downloadable software demos & upgrades • Part configuration tool & cross reference • Online stock check & ordering • IDEC field sales & distributor search • Online literature request • Downloadable manuals & CAD drawings • Manufacturer’s suggested retail price list • Product training schedule & locations • Advertising & trade show schedules • Press releases & FAQs www.idec.com/socket www.idec.com/socket Sockets Selection Guide Relay and Timer Socket Selection Guide Relay and Timer Socket Mounting Series Page DIN Rail Snap/Surface-Mount SU SR SH F Sockets SY F-11 F-14 F-18 F-20 SJ F-9 SH SY F-21 F-22 F-24 PCB Mount SH SY F3-25 F3-26 Compatible IDEC Relay and Timer Terminal SU2S-11L 2 8-Blade SU4S-11L 4 14-Blade 2 8-Pin 3 11-Pin SR3B-05 3 11-Blade SH1B-05 SH1B-05C SH2B-05 SH2B-05C SH3B-05 SH3B-05C SH4B-05 SH4B-05C SY2S-05 SY2S-05C SY4S-05 SY4S-05C SM2S-05 SM2S-05C SJ1S-05B SJ1S-07L SJ2S-05B SJ2S-07L 1 5-Blade 2 8-Blade 3 11-Blade 4 14-Blade 2 8-Blade SQ1V-07B 1 5-Blade RQ1V-CM SQ2V-07B 2 8-Blade RQ2V-CN RQ1V-CH SR2P-51 2 8-Pin RR2P, GT5P, RTE-P1, GT3 (8-pin) SR3P-51 3 11-Pin RR3PA, RR2KP, RTE-P2, GT3 (11-pin) SR3B-51 3 11-Blade RR1BA, RR2BA, RR3B SH1B-51 1 5-Blade RH1B SH2B-51 2 8-Blade SH3B-51 3 11-Blade RH3B, RH2LB SR2P-05 SR2P-05C SR2P-06 SR3P-05 SR3P-05C SR3P-06 Spring Clamp Terminals M3.5 Screw 14-Blade 2 8-Blade 1 5-Blade 2 8-Blade RU4, RU42, RY4, RY42 RR3PA, RR2KP, RTE-P2 GT3 (11-pin) RR1BA, RR2BA, RR3B, RTE-B M3.5 Screw Coil Terminal: M3 RH1B RH2B M3.5 Screw RH3B, RH2LB RH4B RY2S, RY22S M3 Screw 4 RU2, RM2 RR2P, GT5P, RTE-P1, GT3 (8-pin) M3 Screw RU4S, RU42S, RY4S, RY42S, RY2KS, RM2S, GT5Y RU2S, RM2S RJ1S RJ2S M3 Screw F-10 Through Panel Mount SR No. of Receptacle Poles F-6 SM SQ Part No. Solder RH2B SH4B-51 4 14-Blade RH4B SY2S-51 2 8-Blade RY2S, RY22S SY4S-51 4 14-Blade SH1B-62 SH2B-62 SH3B-62 SH4B-62 SY2S-61 1 2 3 4 2 5-Blade 8-Blade 11-Blade 14-Blade 8-Blade SY4S-61 4 14-Blade SY4S-62 4 14-Blade RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S, GT5Y RH1B RH2B RH3B, RH2LB RH4B RY2S, RY22S RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S, GT5Y RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S, GT5Y PC Board For Panel Mounted Timers SR6P-M08G SR F-28 8-pin 2 SR6P-M11G GE1A; RTE-P1; GT3 (8-pin); M3.5 Screw 11-pin RTE-P2; GT3 (11-pin) For relay mounting accessories, see page F-29. F-2 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets Selection Guide Specifications Specifications SU, SR, SH, SM, SY Rated Insulation Voltage 300V; except SH1B, SU and SY4S-62: 250V Rated Current SU2/SR/SH/SM: 10A, SY: 7A, SU4: 6A with RU4, SU4: 10A with RU2 (SH1B: 7A) Insulation Resistance 100MΩ minimum Dielectric Strength 2,000V AC, 1 minute Material Grade UL94V-0 Terminal Torque 3.5mm Screws, 9-11.5 in•lbs 3mm screws, 5.5-9 in•lbs 1. * Applicable to DIN rail sockets only. UL Recognized File No. E62437 CSA Certified File No.LR35144 F Sockets File No. BL950813332307 SJ, SQ SJ Series Specifications Rated Current SJ1S: 12A Max; SJ2S: 8A Max SQ Series SQ1V: 12A Max; SQ2V: 10A Max Rated Voltage 250V 300V Applicable Wire 2x #14 (2.5mm2) 2x #14 (2.5mm2) Applicable Crimping Terminal 2mm2 x 2 1.5mm2 x 2 Terminal Torque 0.6 to 1.0Nm 1.0Nm Max Screw Size M3 Slotted Phillip Captive Screw M3 Slotted Phillip Captive Screw Dielectric Strength (Coil/Contact) 4,000VAC 3,000VAC Insulation Resistance ≥100 MΩ Minimum ≥100 MΩ Minimum Operating Temperature -40 to 70°C (no freezing) -25 to +85°C Operating Humidity 5~85% RH (no condensation) 45~85% RH CSA Certified File No.LR84913 UL Recognized File No. E62437 UL Recognized File No. E141060 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-3 Sockets Selection Guide Hold-Down Springs and Clips Selection Guide DIN Rail Snap/Surface-Mount Sockets Socket Part No. SU2S-11L SU4S-11L SR2P-05 SR2P-05C SR2P-06 SR3P-05 SR3P-05C Sockets F Applicable Relays, Timer Hold-Down Pullover Spring Hold-Down Clip (side latch) Hold-Down Clip (top latch) RM2S, RU2, GT5Y-2 SY4S-51F1 SFA-202 SFA-101 RY4S, RY42S, RU4, RU42, GT5Y, RY2KS, RM2S SY4S-51F1 SFA-202 SFA-101 RR2P SR2B-02F1 SFA-203 — RTE-P1, GT3, GT5P — SFA-203 — RR2P SR2B-02F1 SFA-202 — GT3 (8-pin), RTE-P1, GT5P — SFA-202 — RR3PA SR3B-02F1 SFA-203 — RR2KP SR3P-06F3 SFA-203 — RTE-P2, GT3 (11-pin) — SFA-203 — RR3PA SR3B-02F1 SFA-202 — SR3P-06 RR2KP SR3P-06F3 SFA-202 — RTE-P2, GT3 (11-pin) — SFA-202 — SR3B-05 RR1BA, RR2BA, RR3B, RTE-B SR3B-02F1 SFA-202 — SH1B-05 SH1B-05C RH1B SY2S-02F1 SFA-202 SFA-101 SH2B-05 SH2B-05C RH2B SY4S-02F1 SFA-202 SFA-101 SH3B-05 SH3B-05C RH3B, RH2LB SH3B-05F1 SFA-202 SFA-101 SH4B-05 SH4B-05C RH4B SH4B-02F1 SFA-202 SFA-101 SY2S-05 SY2S-05C RY2S, RY22S SY2S-02F1 SFA-202 SFA-101 RY4S, RY42S, RU4, RU42, RM2S SY4S-51F1 SFA-202 SFA-101 SY4S-05 SY4S-05C RY2KS, GT5Y (SY4S-51F3) SFA-202 SM2S RM2S, RU2 SY4S-51F1 SFA-202 SJ1S SJ2S RQ1S RJ2S SJ9Z-C SQ1S SQ2S RQ1V RQ2V SQ9Z-C SFA-101 1. Hold-down springs work in conjunction with hold-down spring anchors included with DIN rail sockets. 2. When mounting relays with a check button onto panel mount or PC board mount sockets, use the hold-down spring shown in parenthesis. Hold-down springs for relays with check buttons are not available for SR2P-51. 3. For close mounting of panel mount or PC mount sockets, use hold-down clips rather than hold-down springs. 4. SFA-101, SFA-202 and SFA-302 come in pairs. SR2B-02F1 SY4S-51F1 F-4 SR3B-02F1 SY4S-51F3 www.idec.com SH3B-05F1 SY4S-02F1 SR3P-01F1 SR3P-06F3 SH4B-02F1 SY2S-02F1 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets Selection Guide Panel and PC Board Mount Sockets Socket Part No. SR2P-51 SR3P-51 Applicable Relays, Timer Hold-Down Pullover Spring Hold-Down Clip (side latch) Hold-Down Clip (top latch) RR2P SR3P-01F1 — — GT3 (8-pin), RTE-P1 — SFA-402 — RR3PA SR3P-01F1 — — SR3P-51F3 GT3 (11-pin), RTE-P2 — SFA-402 — SR3B-51 RR1BA, RR2BA, RR3B, RTE-B SR3B-02F1 — — SH1B-51 SH1B-62 RH1B SY4S-51F1 — SFA-301 SFA-302 SH2B-51 RH2B SY4S-51F1 (SY4S-02F1) — SFA-301 SFA-302 SH2B-62 RH2B SY4S-51F1 (SY4S-02F1) — — SH3B-51 SH3B-62 RH3B, RH2LB SY4S-51F1 (SY4S-02F1) — SFA-301 SFA-302 SH4B-51 SH4B-62 RH4B SY4S-51F1 (SH4B-02F1) — SFA-301 SFA-302 SY2S-51 SY2S-61 RY2S, RY22S SY4S-51F1 — SFA-301 SFA-302 RY4S, RY42S SY4S-51F1 (SY4S-02F1) — SFA-301 SFA-302 RY2KS SY4S-51F1 (SY4S-02F3) SFA-302 — GT5Y — SFA-302 — RY4S, RY42S, RM2S SY4S-51F1 (SY4S-02F1) — — RY2KS SY4S-51F1 (SY4S-02F3) — — SY4S-51 SY4S-61 SY4S-62 * — F Sockets RR2KP * Does not accept hold down clips SFA-202 SFA-302 SFA-101 SFA-402 SFA-301 www.idec.com SFA-203 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-5 Sockets SU Series: DIN Rail Snap-Mount SU Series: DIN Rail Snap-Mount Sockets SU2S-11L Style SU4S-11L Style 14-blade DIN-mount/surface mount Terminal Spring clamp terminals Terminal Spring clamp terminals Wire Size 24-16 AWG Wire Size 24-16 AWG Electrical Rating 10A Electrical Rating 6A (using RU4), 10A (using RU2) Compatible Relay RU2, RM2 Compatible Relay RY4S, RY42S, RU4, RU42S, RY2KS, RM2S Compatible Timer GT5Y-2 Compatible Timer GT5Y Hold-Down Clip SFA-101 (top latch), SFA-202 (side latch) Hold-Down Clip SFA-101 (top latch), SFA-202 (side latch) Inside the Cable Ports 1. On the SU2S, wires or ferrules cannot be connected to terminals 2, 3, 6, 7, 10 or 11 because neither springs nor conductive brackets are installed in these terminals. 2. For socket mounting accessories, see page F-29. Sockets Inside the Cable Ports Terminal Arrangement (top view) SU2S-11L Dimensions SU4S-11L Center of Relay-mounting area 11 10 9 12 11 10 9 8 7 6 5 8 7 6 5 4 3 2 1 4 3 2 1 13 14 80 12 31 13 37.5 14 28.8 Parts Screwdriver Ports Wire Ports Wire Ports Wire Ports ➃ Wire Ports ➄ ➅ 32 35.3 Marking Plate Spring slots for SFA-101: ➀➁➄➅ 4.4 F 8-blade DIN-mount/surface mount Spring slots for SFA-202: ➁➂➃➄ C NO NC Terminal Terminal Terminal F-6 ➀ ➁ ➂ Coil Terminal Clamp www.idec.com Panel Cutout for Surface Mounting 24 All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SU Series: DIN Rail Snap-Mount SU Series: General Instructions Wiring Instructions Applicable Wires Wire Size Stranded wire 0.2 to 1.25 mm2 or AWG24 to 16 Solid wire 0.2 to 1.5 mm2 or AWG24 to 16 Wire insulation diameter ø3.15mm maximum 1. Strip the wire insulation 9 to 10mm from the end. 2. In applications using ferrules for stranded wires, choose the ferrule listed in table below. Make sure that an insulation sheath is applied when using the ferrules. When using stranded wires without ferrules, make sure that the core wires have not been loosened. 3. Two cable ports are provided for each terminal. 9 to 10mm A - B sec Screwdriver Ports Incorrect Correct Incorrect Incorrect Direction of Screwdriver Tip Note: Two cable ports are provided for each terminal. B 1. Insert the optional screwdriver (BC1S-SDO) or an applicable screwdriver into the squareshaped port as shown on the right, until the screwdriver tip touches the bottom of the spring. Manufacturer 24 A10.25-12BU Phoenix Contact _ 22 A10.34-8TQ Phoenix Contact A10.5-8WH 20 A10.5-10WH TE0.5 Phoenix Contact Nichifu Co. Ltd For wiring, use the optional screwdriver (BC1S-SDO) or the following applicable screwdriver. F Sockets Type AWG 0.2 0.5 Stopper A Wire Ports for Terminal 9 Wire Ports for Terminal 10 2. Push in the screwdriver until it touches the bottom of the port. The wire port is now open, and the screwdriver is held in place. The screwdriver will not come off even if you release your hand. Applicable Ferrules Applicable Wire (stranded) mm2 Wire Port 3. While the screwdriver is retained in the port, insert the wire or ferrule into the round-shaped wire port. Each wire port can accommodate one wire or ferrule. When connecting two wires to one terminal, use the adjoining port of the same terminal. 4. Pull out the screwdriver. The connection is now complete. Safety Precautions Installing the Marking Plate (Dimensions in mm) 7to ø 2.5 13 º 0.4 2.5 Because of its removable structure, the marking plate may have fallen from the socket or become loose in delivery. Make sure that the marking plate is securely installed before starting operation. The marking plate protects the conductive portion of the socket, located under the marking plate, by preventing metal fragments or pieces of wire from dropping inside. Should any such fragments enter the socket, they may cause fire hazard, damage, or malfunction. Jumper Ports Marking Plate Marking Instructions Write markings on the SU sockets using an oil-based marker, or glue printed mylar on the marking surface. The size of the printed mylar can be 8 x 9mm maximum. Marking Surface 8.0 9.0 8.0 Marking Plate www.idec.com No marking plate Loose fitting plate ribs (on both sides) Installed securely Note: For installation of optional p jumper, j p see the instruction sheet provided with the jumper. r Jumper Inserting Screwdriver into the Wire Ports Maximum size of printed mylar Position of printed mylar on the marking surface USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-7 Sockets SU Series: DIN Rail Snap-Mount SU Series: SU9Z-J5 Jumper Installation Instructions SU9Z-J5 Jumper for SU2S-11L and SU4S-11L The SU9Z-J5 is used to install five sockets. When installing less than five sockets cut the jumper according to the instructions listed to the right. The SU9Z-J5 jumper is for coil terminals only. SU9Z-95 Jumper Rated Current Material Installing Two, Three or Four SU Sockets on the SU9Z-J5 Jumper As shown below, slide the jumper in the sheath so that the jumper aligns with the center of the sheath. Jumper off center Jumper on center 3A Conductor Nickel-plated brass Sheath ABS resin With the sheath properly installed on the jumper, cut the sheath and jumper at the points shown below, using cutting pliers. Referring to the drawing on the right, make sure that the sheath and jumper are cut within the cutting area. Dispose of unused portions according to local waste disposal requirements. Installation Z Y Loosen the marking plate on the socket. Shea X Jump Shea Cutting Area C A A: Loose fitting B Cutting Area D Cutting Area in Detail CD B: Installed securely Qty F 2 Sockets Sockets 2 Sockets 3 Sockets 4 Sockets Ribs Cutting Area Discard 2 A, C Y 1 A, B X 1 D Z After cutting the jumper and sheath, slide the jumper as shown below, so that the ends of the jumper ar e not exposed. Grooves for marking plate ribs (on both sides) Alignment Jumper Wiring to Six or More SU Sockets Making sure that the SU9Z-J5 jumper is correctly aligned, insert the blades into the ports in the groove of the SU sockets. To jumper wire six or more SU sockets, connect five sockets using whole jumpers and the remaining sockets using a cut jumper. Then connect the two terminals on adjoining sockets using an applicable wire (see table below). Incorrect Correct Proper wire Insertion Direction Jumper port for terminal 13 Jumper port for terminal 14 Wire Blade Jumper Groove Size Stranded wire 0.2 to 1.25 mm2 Solid wire 0.2 to 1.5 mm2 AWG 24 to 16 1. Use a wire with cable insulation diameter of ø3.15mm maximum. 2. Strip the cable insulation 9 to 10mm from the end. Jumper Install Jumper Securely Press down the marking plate to secure the jumper. The jumper installation is now complete. Safety Precautions Turn off the power to the SU9Z-J5 jumper before starting installation, removal, wiring, maintenance, or inspection of the jumper. Failure to turn power off may cause an electrical shock or fire hazard. To avoid a short circuit due to incorrect wiring, confirm which terminals are connected to the jumper before beginning wiring. F-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SJ Series: DIN Rail Snap-Mount SJ Series: General Information SJ1S-05B Style 5 -blade snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum up to 2 - #14 AWG Electrical Rating 250V, 12A Compatible Relay RJ1S Compatible Timer N/A Hold-Down Spring N/A Replacement Locking Lever SJ9Z-C F 5-blade, snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum up to 2 - #14 AWG Electrical Rating 250V, 12A Compatible Relay RJ1S Compatible Timer N/A Hold-Down Spring N/A Replacement Locking Lever SJ9Z-C SJ2S-05B Style Sockets SJ1S-07L Fingersafe Style 8-blade, snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum up to 2 - #14 AWG Electrical Rating 250V, 8A Compatible Relay RJ2S Compatible Timer N/A Hold-Down Spring N/A Replacement Locking Lever SJ9Z-C All dimensions are in mm. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-9 Sockets SJ/SQ Series: DIN Rail Snap-Mount SJ2S-07L Fingersafe Style 8-blade snap mount/surface mount Terminal/Torque 0.6 - 1.0N•m (Maximum 1.2N•m) Wire Size Maximum up to 2 - #14 AWG Electrical Rating 250V, 8A Compatible Relay RJ2S Compatible Timer N/A Hold-Down Spring N/A Replacement Locking Lever SJ9Z-C All dimensions are in mm. SQ Series: General Information Sockets F SQ1V-07B Fingersafe Style 5-pin, snap mount/surface mount Terminal/Torque 1.0N•m Maximum Wire Size Maximum up to 2 - #14 AWG Electrical Rating 300V, 12A Compatible Relay RQ1V-CM Replacement Locking Lever SQ9Z-C Replacement Marking Plate SQ9Z-P Plug-in LED/Diode (6-24VDC) SQ9Z-LD Plug-in LED/RC (120/240VAC) SQ9Z-LR SQ2V-07B Fingersafe Style 8-pin, snap mount/surface mount Terminal/Torque 1.0N•m Maximum Wire Size Maximum up to 2 - #14 AWG Electrical Rating 300V, 8A Compatible Relay RQ2V, RQ1V-CH Replacement Locking Lever SQ9Z-C Replacement Marking Plate SQ9Z-P Plug-in LED/Diode (6-24VDC) SQ9Z-LD Plug-in LED/RC (120/240VAC) SQ9Z-LR All dimensions are in mm. F-10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SR Series: DIN Rail Snap-Mount SR Series: DIN Rail Snap-Mount Sockets SR2P Sockets 32 when using BAA 36 8 300V, 10A 3 RR2P Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A Hold-Down Spring SR2B-02F1 (for RR2P) Hold-Down Clip SFA-203 (for timers only, except GE1A) 300V, 10A Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A Hold-Down Spring SR2B-02F1 (for RR2P) Hold-Down Clip SFA-203 (for timers only, except GE1A) 7 7.9max. ø3.6min. Terminal Arrangement DIN Rail (BAA) 5 4 6 3 7 2 8 1 2-ø4.2 Mounting Hole (M4 screw hole) 5 21.5 29 25.5 when using BAA Electrical Rating 300V, 10A Compatible Relay RR2P Compatible Timer RTE-P1, GT3 (8-pin), GT5P, GE1A Hold-Down Spring SR2B-02F1 (for RR2P) Hold-Down Clip SFA-202 (for timers only, except GE1A) 1 ø4.2 33 Mounting Hole 6 5 4 3 7 8 1 2 33 4.9max. 22 5min. ø3.6min. (TOP VIEW) 18 7.9max. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com 2 8 Terminal Arrangement DIN Rail (BAA) ø25 Maximum up to 2–#12AWG 7 (cannot use ring terminal) 2-ø4.2 Mounting Hole (M4 screw hole) M3.5 Screw 60 Wire Size 3 30 8-pin octal, snap-mount/surface mount M3.5 screws with captive wire clamp (9 - 11.5 in•lbs) 4 (TOP VIEW) 40 8 Terminal/Torque 5 6 29 4. 1 SR2P-06 Style 20 33.5 when using BAA 36 2.2 RR2P 1 (TOP VIEW) 2 Compatible Relay 2 8 F 58 Electrical Rating 7 Sockets Maximum up to 2–#12AWG 3 5min. 28.5 M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) Wire Size 16.5 Mounting Hole 29 SR2P-05C Fingersafe 8-pin octal, snap-mount/surface mount Style Terminal/Torque 4.4max. ø4.2 Compatible Relay 4 52 Electrical Rating 5 6 29 3 Maximum up to 2–#12AWG 33 Wire Size 2-ø4.2 Mounting Hole (M4 screw hole) ø25 Terminal/Torque M3.5 screws with captive wire clamp (9 - 11.5 in•lbs) Terminal Arrangement DIN Rail (BAA) M3.5 Screw 8-pin octal, snap-mount/surface mount 52 SR2P-05 Style USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC All dimensions are in mm. F-11 Sockets SR Series: DIN Rail Snap-Mount SR3P Sockets 32 when using BAA 42 8 11-pin octal, snap-mount/surface mount Terminal/Torque M3.5 screws with captive wire clamp Wire Size Maximum up to 2–#12AWG Electrical Rating 300V, 10A Compatible Relay RR3PA, RR2KP DIN Rail (BAA) M3.5 Screw 2-ø4.2 Mounting Hole (M4 screw hole) (9 - 11.5 in•lbs) Compatible Timer GT3 (11-pin), RTE-P2 Hold-Down Spring SR3B-02F1 for RR3P; SR3P-06F3 for RR2KP Hold-Down Clip SFA-203 (Timers) Terminal Arrangement 6 7 5 4 52 33 ø27 8 34 9 4.4max. ø4.2 34 5min. 16.5 Mounting Hole 3 SR3P-05 Style 20 3 10 11 2 1 (TOP VIEW) ø3.6min. 7.9max. 28.5 SR3P-05C Fingersafe Style 11-pin octal, snap-mount/surface mount 300V, 10A Compatible Relay RR3PA, *RR2KP (*latching relay) Compatible Timer GT3 (11-pin), RTE-P2 Hold-Down Spring SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP Hold-Down Clip SFA-203 (Timers) 6 5 8 4 9 3 ø 5 7 58 Maximum up to 2–#12AWG Electrical Rating 2-ø4.2 Mounting Hole (M4 screw hole) 1 0 1 1 1 Terminal/Torque 9 2 1 (TOP VIEW) 2 21.5 59 M3.5 screws with captive wire clamp 25.5 when using BAA 8 (9 - 11.5 in•lbs) (cannot use ring terminal) Terminal Arrangement DIN Rail (BAA) M3.5 Screw 2-ø4.2 Mounting Hole (M4 screw hole) Electrical Rating 300V, 10A Compatible Relay RR3PA, *RR2KP (*latching relay) ø4.2 Compatible Timer GT3 (11-pin), RTE-P2 Mounting Hole Hold-Down Spring SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP Hold-Down Clip SFA-202 (Timers) 60 ø27 Maximum up to 2–#12AWG www.idec.com 3 10 11 Wire Size F-12 5 4 8 30 11-pin octal, snap-mount/surface mount 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. 6 7 34 ø4 .2 34 SR3P-06 Style Terminal Arrangement DIN Rail (BAA) M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) Wire Size 33.5 when using BAA 7 2.2 Terminal/Torque 42 33 1 Sockets F 8 7 6 5 4 2 3 33 4.9max. 18 22 5min. ø3.6min. 9 10 11 1 (TOP VIEW) 7.9max. All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SR Series: DIN Rail Snap-Mount SR3B Sockets When using BAA/BAP: 28.5 36 8 M3.5 Terminal Screw 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 4.2 6 5 4 3 2 1 37 56 11-blade, snap-mount/surface mount 76 SR3B-05 Style Terminal Arrangement DIN Rail (BAA/BAP) A B Terminal/Torque M3.5 screws with captive wire clamp Wire Size Maximum up to 2–#12AWG 4.4 max. 5.5 min. (9 - 11.5 in•lbs) 9 8 7 2 (Top View) Electrical Rating 300V, 15A (10A)* (*denotes CSA rating) Compatible Relay RR1BA, RR2BA, RR3B Compatible Timer RTE-B Hold-Down Spring SR3B-02F1 (relays) Hold-Down Clip SFA-202 (relays and timers) 37 43 14.5 7.9 max. ø3.6 min. 25 All dimensions are in mm. F Sockets 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-13 Sockets SH Series: DIN Rail Snap-Mount SH Series: DIN Rail Snap-Mount Sockets SH1B Sockets When using BAA/BAP: 28.5 17 8 Terminal/Torque Wire Size Maximum up to 2–#12AWG Electrical Rating 250V, 10A Compatible Relay RH1B Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) Maximum up to 2–#12AWG Electrical Rating 250V, 10A Compatible Relay RH1B Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-14 www.idec.com 1 13 9 47 (Top View) 14.5 20 14 4 max. 4.4 max. 16 ø3.2 min. ø3.6 min. 25 7.9 max. 5.9 max. (For terminals 1, 5, and 9) SH1B-05C Fingersafe Style 5-blade, snap-mount/surface mount Wire Size 5 4.8 min. 5.5 min. M3 Terminal Screw 7 (For terminals 13 and 14) When using BAA/BAP: 33 M3.5 Terminal Screw 25 DIN Rail (BAA/BAP) Terminal Arrangement 5 ø5 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 1 48 4.2 69 Terminal/Torque Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 16 17 (Coil) M3 screws/(5.5 - 9 in•lbs) (contact) M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) DIN Rail (BAA/BAP) 18 4.2 67 (Coil) M3 screws/(5.5 - 9 in•lbs) (contact) M3.5 screws (9 - 11.5 in•lbs) with captive wire clamp 16 M3 Terminal Screw 14 13 9 16 1.7 Sockets F 5-blade, snap-mount/surface mount 2.5 SH1B-05 Style M3.5 Terminal Screw 20 18.7 Ring type crimping terminals cannot be used. (Top View) 29.5 All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SH Series: DIN Rail Snap-Mount SH2B Sockets When using BAA/BAP: 28.5 22 8 Wire Size Maximum up to 2–#12AWG Electrical Rating 300V, 10A Compatible Relay RH2B Hold-Down Spring SY4S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) DIN Rail (BAA/BAP) Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 47 M3.5 screws with captive wire clamp (9 - 11.5 in•lbs) 8 5 4 1 14 13 12 9 26 4.4 max. 2.5 Terminal/Torque 18 4.2 8-blade, snap-mount/surface mount 67 SH2B-05 Style M3.5 Terminal Screw 26 14.5 30 25 5.5 min. (Top View) 7.9 max. ø3.6 min. F SH2B-05C Fingersafe Style 8-blade, snap-mount/surface mount Maximum up to 2–#12AWG Electrical Rating 300V, 10A RH2B Hold-Down Spring SY4S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com ø5 DIN Rail (BAA/BAP) Terminal Arrangement 2-ø4.2 Mounting Holes (or M4 Tapped Holes) 8 5 4 1 14 13 12 9 26 1.7 Compatible Relay 25 49 Wire Size M3.5 Terminal Screw 4.2 M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) 69 Terminal/Torque 7 26 30 18.7 29.5 Ring type crimping terminals cannot be used. (Top View) All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-15 Sockets When using BAA/BAP: 33 22 Sockets SH Series: DIN Rail Snap-Mount SH3B Sockets 18 Maximum up to 2–#12AWG Electrical Rating 300V, 10A M3.5 Screw Terminal Arrangement DIN Rail (BAA) 2-ø4.2 Mounting Hole (M4 screw hole) 8 6 5 4 2 1 47 Wire Size Compatible Relay 8 M3.5 screws with captive wire clamp (9 - 11.5 in•lbs) 4.2 Terminal/Torque 28.5 when using BAA 32 11-blade, snap-mount/surface mount 67 SH3B-05 Style 36 4.4max. RH3B, RH2LB 5.5min. 14 12 SH3B-05F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 36 2.5 Hold-Down Spring 14.5 25 40 13 10 9 (TOP VIEW) 7.9max. ø3.6min. SH3B-05C Fingersafe Style 11-blade, snap-mount/surface mount Terminal/Torque 7 M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) 8 44 Wire Size Maximum up to 2–#12AWG 24 14 4 2 RH3B, RH2LB 1 22 A2 Hold-Down Clip SH3B-05F1 SFA-101 (top notch), SFA-202 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-16 www.idec.com 2-ø4.2 Mounting Hole (M4 screw hole) 10 36 40 8 6 5 4 2 1 36 14 13 21 41 12 Terminal Arrangement A1 14 1.7 Hold-Down Spring ø5 12 49 Compatible Relay 25 5 4.2 300V, 10A M3.5 Screw 6 42 Electrical Rating 33 when using BAA 32 DIN Rail (BAA) Sockets F 12 13 10 9 11 (cannot use ring terminal) 9 (TOP VIEW) 18.7 29.5 All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SH Series: DIN Rail Snap-Mount SH4B Sockets 28.5 when using BAA 42 8 14-blade, snap-mount/surface mount Wire Size Maximum up to 2–#12AWG Electrical Rating 300V, 10A Compatible Relay RH4B Hold-Down Spring SH4B-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 2-ø4.2 Mounting Hole (M4 screw hole) 8 4 7 3 6 5 2 1 11 10 47 M3.5 screws with captive wire clamp (9 - 11.5 in•lbs) Terminal Arrangement DIN Rail (BAA) 4.2 Terminal/Torque 18 M3.5 Screw 67 SH4B-05 Style 46 4.4max. 5.5min. 14 13 12 ø3.6min. 2.5 46 14.5 25 50 9 (TOP VIEW) 7.9max. F Sockets SH4B-05C Fingersafe Style 14-blade, snap-mount/surface mount Terminal/Torque 44 8 7 6 34 24 14 3 2 1 32 22 12 4 RH4B Hold-Down Spring SH4B-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) ø5 2-ø4.2 Mounting Hole (M4 screw hole) 8 4 7 3 6 5 2 1 11 10 49 300V, 10A Compatible Relay 69 Electrical Rating Terminal Arrangement DIN Rail (BAA) 5 4.2 42 Maximum up to 2–#12AWG 25 7 M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs) Wire Size 33 when using BAA 42 A2 13 41 31 11 21 10 1.7 12 46 A1 14 46 14 11 9 12 18.7 29.5 (cannot use ring terminal) 13 9 (TOP VIEW) 50 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-17 Sockets SY Series: DIN Rail Snap-Mount SY Series: DIN Rail Snap-Mount Sockets SY2S Sockets 6 8-blade, snap-mount/surface mount Maximum up to 2–#14AWG Electrical Rating 300V, 7A Compatible Relay RY2S, RY22S Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 8 5 4 1 14 13 12 9 45 Wire Size 2-ø4.2 Mounting Hole (M4 screw hole) 16 4.2 M3 screws with captive wire clamp (5.5 - 9 in•lbs) Terminal Arrangement DIN Rail (BAA) M3 Screw 62 Terminal/Torque 18 4max. 16 4.8min. ø3.2min. 14.5 5.9max. 25 20 (TOP VIEW) Sockets F 28.5 when using BAA 17 2 SY2S-05 Style 32.5 when using BAA Terminal/Torque 17.2 6 M3 screws with captive wire clamp, fingersafe (5.5 - 9 in•lbs) 8 5 44 14 1 4 300V, 7A Compatible Relay RY2S, RY22S Hold-Down Spring SY2S-02F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) 12 4.2 Electrical Rating 42 46 Maximum up to 2–#14AWG A2 F-18 www.idec.com 13 11 12 1.6 8 5 4 1 14 13 12 9 16 2 41 2-ø4.2 Mounting Hole (M4 screw hole) A1 14 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. ø5 64 Wire Size Terminal Arrangement 25 M3 Screw DIN Rail (BAA) SY2S-05C Fingersafe Style 8-blade, snap-mount/surface mount 16 20 (TOP VIEW) 9 18.2 29 (cannot use ring terminal) All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SY Series: DIN Rail Snap-Mount SY4S Sockets using BAA 6 18 M3 screw with captive wire clamp (5.5 - 9 in•lbs) 300V, 7A Compatible Relay RY4S, RY42S, RU4S, RU42S, RM2S, *RY2KS, (*latching relay) 2-ø4.2 Mounting Hole (M4 screw hole) 8 7 6 5 4 3 2 1 45 Maximum up to 2–#14AWG Electrical Rating Terminal Arrangement DIN Rail (BAA) M3 Screw 62 Wire Size Compatible Timer 0.7 14-blade, snap-mount/surface mount 26 4.2 Terminal/Torque 28.5 when 30 4max. GT5Y 18.5 Hold-Down Spring SY4S-51F1 for all relays; SY4S-51F3 for RY2KS only Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) for all relays and timers 26 14 4.8min. ø3.2min. 3 SY4S-05 Style 13 12 11 10 9 (TOP VIEW) 5.9max. 25 F Sockets Terminal/Torque M3 screw with captive wire clamp, fingersafe (5.5 - 9 in•lbs) Wire Size Maximum up to 2–#14AWG 30 M3 Screw 7 8 34 44 4 Electrical Rating 300V, 7A Compatible Relay RY4S, RY42S, RM2S, RU4S, RU42S, *RY2KS, (*latching relay) Compatible Timer GT5Y Hold-Down Spring SY4S-51F1 for all relays; SY4S-51F3 for RY2KS only Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) for GT5Y timer and relays 25 6 32 5 14 2 22 1 ø5.5 18 Terminal Arrangement 2-ø4.2 Mounting Hole (M4 screw hole) 8 7 6 5 4 3 2 1 12 64 46 4.2 42 6 24 3 DIN Rail (BAA) 32.5 when using BAA SY4S-05C Fingersafe Style 14-blade, snap-mount/surface mount 26 14 A2 1.6 12 12 11 10 9 13 31 11 21 10 11 9 2.0 41 13 A1 14 (TOP VIEW) (cannot use ring terminal) 26 18.2 29 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-19 Sockets SM Series: DIN Rail Snap-Mount SM2S Sockets Maximum up to 2–#14AWG Electrical Rating 300V, 10A Compatible Relay RU2S, RM2S Compatible Timer — Hold-Down Spring SY4S-51F1 Hold-Down Clip SFA-101 (top notch), SFA-202 (side notch) Terminal Arrangement DIN Rail (BAA) M3 Screw 2-ø4.2 Mounting Hole (M4 screw hole) 8 5 4 1 14 13 12 9 26 4max. 4.8min. ø3.2min. 18.5 5.9max. 25 26 (TOP VIEW) Sockets F 18 45 Wire Size 6 4.2 M3 screw with captive wire clamp (5.5 - 9 in•lbs) 3 Terminal/Torque 28.5 when using BAA 30 0.7 8-blade, snap-mount/surface mount 62 SM2S-05 Style Wire Size Maximum up to 2–#14AWG Electrical Rating 300V, 10A Compatible Relay RU2S, RM2S M3 Screw 8 44 Compatible Timer SFA-101 (top notch), SFA-202 (side notch) 22 1 18 ø5.5 12 2-ø4.2 Mounting Hole (M4 screw hole) 8 5 4 1 14 13 12 46 64 12 9 26 A1 14 1.6 Hold-Down Clip 32 5 14 2 A2 41 SY4S-51F1 24 3 Terminal Arrangement 4.2 42 6 7 34 4 — Hold-Down Spring 25 6 13 31 11 26 21 10 2 Terminal/Torque M3 screw with captive wire clamp, fingersafe (5.5 - 9 in•lbs) 30 DIN Rail (BAA) 32.5 when using BAA SM2S-05C Fingersafe Style 8-blade, snap-mount/surface mount 11 (TOP VIEW) 9 18.2 29 (cannot use ring terminal) All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-20 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SR Series: Panel Mount SR Series: Panel Mount Sockets 1 4 2 5 3 6 7 8 9 A 6.5 3 22 Solder Electrical Rating 300V, 10A Compatible Relay RR1BA, RR2BA, RR3B Compatible Timer RTE-B Hold-Down Spring SR3B-02F1 (for relays only) (Bottom View) (Tolerance ±0.3) ∗ When two or more sockets are mounted side by side: L = 38 (N – 1) + 35.5 N: No. of sockets mounted 3.5 35 2-ø3.5 Mounting Holes (or M3 Tapped Holes) 5 1 8 0 4 3 6 2 ø3 38 ø29 Terminal Arrangement 7 8-pin octal, panel mount Terminal Solder Electrical Rating 300V, 10A Compatible Relay RR2P Compatible Timer RTE-P1, GT3 (8-pin), GT5P Hold-Down Spring SR3P-01F1 (for relay only) Hold-Down Clip SFA-402 (for GT3 8-pin) SFA-302 (for GT5P) 34 2.5 10 11 (Bottom View) Panel Surface 2.5 6 4.2 2-ø3.5 Mounting Holes (or M3 Tapped Holes) Terminal Arrangement 11-pin octal, panel mount Terminal Solder Electrical Rating 300V, 10A Compatible Relay RR3PA, *RR2KP (*latching relay) Compatible Timer GT3 (11-pin), RTE-P2 Hold-Down Spring SR3P-01F1 for RR3PA SR3P-51F3 for RR2KP Hold-Down Clip SFA-402 (for GT3 11-pin, RTE-P2) 2 34 2.5 10 11 (Bottom View) 2.5 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com 38 9 10 0 8 1 11 ø3 ø29 38 50 5 6 7 4 3 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F Sockets 50 6 4.2 SR3P-51 Style B 2-ø4.2 Mounting Holes (M4 Tapped Holes) 38 Terminal SR2P-51 Style 35.5∗ 22 11-blade, panel mount Panel Surface SR3B-51 Style 6.75 32.5 43 0.3 35 43 51.5 Terminal Arrangement 11.5 min. 11 max. 7.5 32 38 All dimensions are in mm. F-21 Sockets SH Series: Panel Mount SH Series: Panel Mount Sockets 1 5 9 25.4 31 [18 (N–1) + 12.4] +0.5 0 Terminal Arrangement 25.6 +0.2 0 Panel Thickness: 1 to 2 3 (Bottom View) 11 5-blade, panel mount Terminal Solder Electrical Rating 300V, 10A Compatible Relay RH1B Hold-Down Spring SY4S-51F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 18.7 3.5 N: No. of sockets mounted 5.4 min.∗ SH1B-51 Style 0.3 13 14 18 ∗ 10.4 min. when using hold-down springs 2.4 12.2 31 [27 (N–1) + 21.4] +0.5 0 Terminal Arrangement 1 4 5 8 9 12 +0.2 0 25.4 Panel Thickness: 1 to 2 25.6 Sockets F 11 8-blade, panel mount Terminal Solder Electrical Rating 300V, 10A Compatible Relay RH2B Hold-Down Spring SY4S-51F1 SY4S-02F1 for RH2B-4C Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 18.7 (Bottom View) 5.4 min.∗ 3 27 0.3 13 14 SH2B-51 Style N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 21.2 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SH Series: Panel Mount SH Series: Panel Mount Sockets, continued [36 (N–1) + 30.4] +0.5 0 0.3 11 11-blade, panel mount 18.7 Terminal Solder Electrical Rating 300V, 10A Compatible Relay RH3B, *RH2LB (*latching relay) Hold-Down Spring SY4S-51F1 SY4S-02F1 for RH3B-4C Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 30.2 F Terminal Arrangement 1 2 3 4 5 6 7 8 9 10 11 12 Solder Electrical Rating 300V, 10A Compatible Relay RH4B Hold-Down Spring SY4S-51F1, SY4S-02F1 Hold-Down Clip SFA-301, SFA-302 11 18.7 0.3 3 14 (Bottom View) 5.4 min.∗ Terminal 45 +0.2 25.6 0 25.4 31 [45 (N–1) + 39.4] +0.5 0 13 14-blade, panel mount Sockets Panel Thickness: 1 to 2 SH4B-51 Style 14 (Bottom View) 5.4 min.∗ 3 36 25.6 31 1 2 4 5 6 8 9 10 12 13 SH3B-51 Style +0.2 0 Terminal Arrangement 25.4 Panel Thickness: 1 to 2 N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 3.5 39.2 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-23 Sockets SY Series: Panel Mount SY Series: Panel Mount Sockets Panel Thickness: 1 to 2 [18(N–1)+12.4] +0.5 0 Solder Electrical Rating 300V, 7A Compatible Relay RY2S, RY22S Hold-Down Spring SY4S-51F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 3 0 25.6 13 14 (Bottom View) 5.4 min.∗ 8-blade, panel mount Terminal 1 4 5 8 9 12 25.4 18 0.3 31 SY2S-51 Style +0.2 Terminal Arrangement 11 18.7 N: No. of sockets mounted ∗ 10.4 min. when husing hold-down springs 2.4 12.2 Terminal Solder Electrical Rating 300V, 7A Compatible Relay RY4S, RY42S, RM2S, RY2KS, RU4S, RU2S, RU42S Compatible Timer GT5Y Hold-Down Spring SY4S-51F1 for all relays except; SY4S-02F3 for RY2KS relay Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) [27 (N–1) + 21.4] + 0.5 0 13 3 27 11 18.7 2.4 14 (Bottom View) 0 25.6 1 2 3 4 5 6 7 8 9 10 11 12 +0.2 Terminal Arrangement 5.4 min.∗ 14-blade, panel mount 0.3 SY4S-51 Style 25.4 Panel Thickness: 1 to 2 31 Sockets F N: No. of sockets mounted ∗ 10.4 min. when using hold-down springs 21.2 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-24 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SH Series: PCB Mount SH Series: PC Board Mount Sockets 15 Terminal Solder/PCB mount Electrical Rating 250V, 10A Compatible Relay RH1B 5.95 11.85 0.3 (Bottom View) 11 5-blade 4.4 31 min.∗ SH1B-62 Style 3 18 min. 4.7 6.95 31 25.4 1 5 9 13 14 18 6.8 3-ø2.4 holes Terminal Arrangement 2 1.5 2-ø2 holes (Tolerance ±0.1) ∗ 36 min. when using hold-down springs 12.2 Hold-Down Spring SY4S-51F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) F Terminal Solder/PCB mount Electrical Rating 300V, 10A Compatible Relay RH2B Hold-Down Spring SY4S-51F1, SY4S-02F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 5.65 10 (Bottom View) 11 15 2 6.6 3 21.2 15.5 14 29 min.∗ 12.5 8-blade 0.3 13 4.7 25.4 29 SH2B-62 Style 21.5 min. 2.85 1 4 5 8 9 12 8-ø2.4 holes (Tolerance ±0.1) ∗ 34 min. when using hold-down springs 36 min. 15 Terminal Solder/PCB mount Electrical Rating 300V, 10A Compatible Relay RH3B, *RH2LB 2 30.2 6.6 11 11-blade 10 10 14 (Bottom View) 31 min.∗ SH3B-62 Style 0.3 13 3 21.3 7.35 4.7 1 2 4 5 6 8 9 10 12 12.5 6.65 31 25.4 Terminal Arrangement 36 Sockets Terminal Arrangement 11-ø2.4 holes (Tolerance ±0.1) ∗ 36 min. when using hold-down springs (*latching relay) Hold-Down Spring SY4S-51F1, SY4S-02F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com All dimensions are in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-25 Sockets SH/SY Series: PCB Mount Terminal Arrangement 6.85 1 2 3 4 5 6 7 8 9 10 11 12 4.7 6.65 11 Terminal Solder/ PCB mount Electrical Rating 300V, 10A Compatible Relay RH4B Hold-Down Springs SY4S-51F1, SH4B-02F1 Hold-Down Clip SFA-301 (top notch), SFA-302 (side notch) 2 6.6 15 14-blade 10 10 10 14 (Bottom View) 31 min.∗ SH4B-62 Style 0.3 13 3 45 45 min. 31.3 12.5 31 25.4 SH Series: PC Board Mount Sockets, continued 14-ø2.4 holes ∗ 36 min. when using hold-down springs 39.2 (Tolerance ±0.1) Sockets F Solder/PCB mount Electrical Rating 300V, 7A Compatible Relay RY2S, RY22S Hold-Down Spring SY4S-51F1 3 18 11 15 1.5 0.3 13 14 8-blade Terminal Hold-Down Clip (Bottom View) ∗ 19.2 min. when using hold-down springs 4.4 13.6 min. 9 16.8 1 4 5 8 9 12 14.2 min.∗ 31 SY2S-61 Style 25.4 Terminal Arrangement 4.1 10.4 SY Series: PC Board Mount Sockets 8-ø2 holes (Tolerance ±0.1) 12.2 SFA-301 (top notch), SFA-302 (side notch) All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-26 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets SY Series: PCB Mount SY Series: PC Mount Sockets, continued 13.2 13.8 min. 3 300V, 7A Compatible Relay RY4S, RY42S, RM2S, *RY2KS, RU4S, RU42S, RU2S (*latching relay) 9 16.8 (Bottom View) 11 Electrical Rating Compatible Timer 27 Solder/PCB mount 1 2 3 4 5 6 7 8 9 10 1112 13 14 4.4 14.2 min.∗ 14-blade 0.3 15 15-ø2 holes 1.4 Terminal 31 SY4S-61 Style 25.4 Terminal Arrangement 4.1 10.4 8.8 (Tolerance ±0.1) ∗ 19.2 min. when using hold-down springs 1.5 21.2 GT5Y Hold-Down Spring SY4S-51F1, SY4S-02F1 Hold-Down Clip SFA-301 (top notch; except GT5Y and RY2KS) SFA-302 (side notch for all) F Sockets 13.2 8.2 min.∗∗ 8.8 4.1 4.4 Solder/PCB mount Electrical Rating 250V, 7A Compatible Relay RY4S, RY42S, RU4S, RU42S, *RY2KS (*latching relay) Compatible Timer GT5Y Hold-Down Spring SY4S-51F1, SY4S-51F3, SY4S-51F4, *SY4S-02F1, *SY4S-02F3 (*when mounting a relay with check button) 21.2 (Bottom View) 3 11 15 1.5 9 15-ø2 holes 12.2 min.∗ Terminal 1.4 14-blade 1 2 3 4 5 6 7 8 9 10 1112 13 14 16.8 10.4 29 SY4S-62 Style 0.3 Terminal Arrangement (Tolerance ±0.1) ∗ 17.2 min. when using a hold-down spring. ∗∗ 13.2 min. when using a hold-down spring for the relay with check button. All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-27 Sockets Other Sockets SR Series: Socket for Panel Mounted Timers 8-M3.5 0.8~5mm 44.6 3.5max. 4 M3.5 screws with captive wire clamp Electrical Rating 300V, 10A Wire Size Maximum up to 2-#12AWG Compatible Timer GT3 (8-pin), RTE-P1, GE1A Hold-Down Spring SY4S-02F1 1 8 7 7 8-pin Terminal 5.6min. ø3.6min. 6 6.9max. 2 SR6P-M08G Style 5 30.4 44.6 3 9.8x3 80.5 F 11-M3.5 45 3.5max. 2 1 11 3 8 7 6 45 6.9max. 4 SR6P-M11G Style 11-pin Terminal M3.5 screws with captive wire clamp Electrical Rating 300V, 10A Wire Size Maximum up to 2-#12AWG Compatible Timer GT3 (11-pin), RTE-P2 Hold-Down Spring ------ 30.5 92 5.8min. ø3.6min. 5 34 Sockets 16.7 9 10 7 8.5x4 All dimensions are in mm. 1. For socket mounting accessories, see page F-29. 2. For hold-down clip/spring selections, see page F-4. F-28 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets Accessories Accessories SA-203 18mm 5mm Description SA-204 SA-203 M4 screw washer hold-down spring Appearance Use with Part No. Remarks Aluminum DIN Rail (1 meter length) All DIN rail sockets BNDN1000 IDEC offers a low-profile DIN rail (BNDN1000). The BNDN1000 is designed to accommodate snapmount sockets. Made of durable extruded aluminum, the BNDN-1000 measures 0.413 in height and 1.37 (35mm) in width (DIN standard). Standard length is 39" (1,000mm). DIN Rail End Stop DIN rail BNL5 9.1 mm wide. Surface Mount End Connector SY2S, SY4S, SR3B, SH1B, SH2B, SH3B, SH4B SA-203 For use on ends of socket groupings when surface mounting. SA-204 For use between adjoining sockets when surface mounting. Surface Mount Connector SY2S, SY4S, SR3B, SH1B, SH2B, SH3B, SH4B SA-405 For use between adjoining sockets when surface mounting. DIN Rail Spacer All DIN rail sockets SA-406 SY4S-51, SH2B-51 SA-402 11.42" length with 10 holes. SY4S-51, SH2B-51 SA-403 23.33" length with 21 holes. RH2B, RM2S, RY4S, RY42S, RU4S, RU42S RH-01 RY2S, RH1B RH-03 Replacement HoldDown Spring Anchor Horseshoe clip for all DIN rail sockets except SR*P-05(C) Y778-011 For use with hold-down springs (bale wire types). or DIN rail mount sockets. 2 pieces included with each socket. Hold-Down Spring for SR*P-05(C) Chair clip for SR*P-05(C) Y703-102 For SR2P-05, SR2P-05C, SR3P-05, SR3P-05C F Relay Holders www.idec.com For diagram, see next page. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-29 Sockets Steel Mounting Plates (for panel mount sockets) Sockets Instructions Instructions Mounting Snap-Mount Sockets Snap-mount sockets are designed to mount on the BNDN-1000 Mount mounting rail. The built-in mounting clip eliminates mounting hardware and reduces mounting time by 80%. To mount see Figure 1. Place the end of the socket (end opposite of mounting clip against the outer edge of the rail). Press the socket down firmly until the clip snaps onto the mounting rail. To remove see Figure 2. Pull out the mounting clip with a screwdriver, and lift the socket. Figure 1 Remove For spacing between adjoining sockets, use the SA-406 DIN rail spacer. Spacers are 0.195" wide. Spacing can be adjusted according to the number of spacers added. Spacers snap on and off easily like snap-mount sockets. Hold-Down Spring To prevent side-to-side movement, use a BNL-5 end clip at each end of every socket row. Figure 2 Mounting Relay Holders Sockets F RH-01 or -03 Mount directly onto panel boards in two alternate positions: A and B (see Figure 1). Figure 1 To mount the relay into the holder, hook the bottom edge of the relay case (coil terminal side) onto the relay holder (see Figure 2). Push down until the relay snaps into place. Figure 2 Mounting Hold-Down Springs Take the two anchor clips (horseshoe / U-shaped piece) that come with the socket and insert into the slits on both sides of the socket. Make sure the raised notches on the anchor clip face into the socket. Plug relay into socket Insert the open ends of the hold-down spring into either the first or second hole of the anchor clip. The relay-spring combination will determine which hole should be used. Slide spring over relay. F-30 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Sockets Dimensions Dimensions Surface Mount Sockets (SH2B-02) IDEC surface mount sockets (SH2B-02) are also designed to mount individually or collectively on a flat surface without the use of a DIN rail. Use the mounting screw between adjoining sockets and at the outer ends of the row of sockets. Dimension Table Socket Part No. Dimension A SH2B-02 1.14" A A A 1. Drawing is not to scale. F Snap-Mount Sockets Sockets Snap-mount sockets are designed to mount individually or collectively without using a rail. Use a SA-405 connector or SA-204 connector between adjoining sockets (see Figures 1 and 2). Use the SA-203 end connector at the outer ends of each socket row when using the SA-204 connector (see Figure 2). Dimension Table Socket Part No. Dim. B Dim. C Dim. D SY2S-05, SY2S-05C 0.669" 0.826" 0.866" SY4S-05, SY4S-05C 1.024" 1.181" 1.220" SR3B-05 1.496" 1.693" 1.732" SH1B-05, SH1B-05C 0.630" 0.787" 0.827" SH2B-05, SH2B-05C 1.024" 1.181" 1.220" SH3B-05, SH3B-05C 1.417" 1.575" 1.614" SH4B-05, SH4B-05C 1.811" 1.969" 2.008" Using an SA-406 Connector B C C C C Using SA-203 or SA-204 Connectors D D 0.165" Hole or M4 Tapped D 2. Drawings are not to scale. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC F-31 Sockets Dimensions Dimensions, continued Collective Panel Mounting SH and SY series panel mount sockets are designed to mount collectively in panel cut-outs. Insert socket with mounting springs facing the top and bottom edge of the panel cut-out. Push the socket until the mounting spring clips onto the panel. (See Figure 1.) SY4S-51 Dimension Table Part No. Width Figure 1 RH2B RY2KS RH1B RM2S Relay SY4S-51 1.063" RY4S, RY42, RY2KS, RM2S SH4B-51 1.772" RH4B SH3B-51 1.418" RH3B, RH2LB SH2B-51 1.063" RH2B SH1B-51 0.709" RH1B SY2S-51 0.709" RY2S, RY22S How to Calculate Cutout Length (L) Cutout L = A (Total Overall Width of Each Socket) – 0.221" (+ 0", – 0.020") F Sockets Example: A = Total Overall Width of Each Socket Cutout L = A – 0.221" (+ 0", – 0.020") SY2S-51 SY4S-51 SY4S-51 SY4S-51 SY2S-51 SY4S-51 SH1B-51 SH1B-51 SH2B-51 L = [0.709" + 1.063" + 1.063" + 0.709" + 1.063" + 0.709" + 1.063" + 1.063"] – 0.221" = 7.93" L = 7.93" (+ 0", – 0.020") Mounting Plate F-32 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC