F Sockets

advertisement
F
Din Rail Snap/Surface-Mount
Sockets
• SU Series . . . . . . . . . . . . . . . . . . . ..F-6
New • SJ Series . . . . . . . . . . . . . . . . . . . . ..F-9
New • SQ Series . . . . . . . . . . . . . . . . . . . F-10
• SR Series . . . . . . . . . . . . . . . . . . . F-11
• SH Series . . . . . . . . . . . . . . . . . . . F-14
• SY Series . . . . . . . . . . . . . . . . . . . F-18
• SM Series . . . . . . . . . . . . . . . . . . . F-20
Sockets
Section
Selection Guide.................................. F-2
Through Panel Mount Sockets
• SR Series . . . . . . . . . . . . . . . . . . . F-21
• SH Series . . . . . . . . . . . . . . . . . . . F-22
• SY Series . . . . . . . . . . . . . . . . . . . F-24
PCB Mount Sockets
• SH Series . . . . . . . . . . . . . . . . . . . F-25
• SY Series . . . . . . . . . . . . . . . . . . . F-26
Panel Mounted Sockets for Timers
• SR Series . . . . . . . . . . . . . . . . . . . F-28
Accessories ....................................... F-29
Dimensions....................................... F-31
for more information on this product family visit
Additional Web Resources
• New and updated product information
• Downloadable software demos & upgrades
• Part configuration tool & cross reference
• Online stock check & ordering
• IDEC field sales & distributor search
• Online literature request
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
www.idec.com/socket
www.idec.com/socket
Sockets
Selection Guide
Relay and Timer Socket Selection Guide
Relay and Timer Socket
Mounting
Series Page
DIN Rail Snap/Surface-Mount
SU
SR
SH
F
Sockets
SY
F-11
F-14
F-18
F-20
SJ
F-9
SH
SY
F-21
F-22
F-24
PCB Mount
SH
SY
F3-25
F3-26
Compatible
IDEC Relay and Timer
Terminal
SU2S-11L
2
8-Blade
SU4S-11L
4
14-Blade
2
8-Pin
3
11-Pin
SR3B-05
3
11-Blade
SH1B-05
SH1B-05C
SH2B-05
SH2B-05C
SH3B-05
SH3B-05C
SH4B-05
SH4B-05C
SY2S-05
SY2S-05C
SY4S-05
SY4S-05C
SM2S-05
SM2S-05C
SJ1S-05B
SJ1S-07L
SJ2S-05B
SJ2S-07L
1
5-Blade
2
8-Blade
3
11-Blade
4
14-Blade
2
8-Blade
SQ1V-07B
1
5-Blade
RQ1V-CM
SQ2V-07B
2
8-Blade
RQ2V-CN
RQ1V-CH
SR2P-51
2
8-Pin
RR2P, GT5P, RTE-P1, GT3 (8-pin)
SR3P-51
3
11-Pin
RR3PA, RR2KP, RTE-P2, GT3 (11-pin)
SR3B-51
3
11-Blade
RR1BA, RR2BA, RR3B
SH1B-51
1
5-Blade
RH1B
SH2B-51
2
8-Blade
SH3B-51
3
11-Blade
RH3B, RH2LB
SR2P-05
SR2P-05C
SR2P-06
SR3P-05
SR3P-05C
SR3P-06
Spring Clamp
Terminals
M3.5 Screw
14-Blade
2
8-Blade
1
5-Blade
2
8-Blade
RU4, RU42, RY4, RY42
RR3PA, RR2KP, RTE-P2
GT3 (11-pin)
RR1BA, RR2BA, RR3B, RTE-B
M3.5 Screw
Coil Terminal: M3
RH1B
RH2B
M3.5 Screw
RH3B, RH2LB
RH4B
RY2S, RY22S
M3 Screw
4
RU2, RM2
RR2P, GT5P,
RTE-P1, GT3 (8-pin)
M3 Screw
RU4S, RU42S, RY4S, RY42S, RY2KS, RM2S,
GT5Y
RU2S, RM2S
RJ1S
RJ2S
M3 Screw
F-10
Through Panel Mount
SR
No. of
Receptacle
Poles
F-6
SM
SQ
Part No.
Solder
RH2B
SH4B-51
4
14-Blade
RH4B
SY2S-51
2
8-Blade
RY2S, RY22S
SY4S-51
4
14-Blade
SH1B-62
SH2B-62
SH3B-62
SH4B-62
SY2S-61
1
2
3
4
2
5-Blade
8-Blade
11-Blade
14-Blade
8-Blade
SY4S-61
4
14-Blade
SY4S-62
4
14-Blade
RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
GT5Y
RH1B
RH2B
RH3B, RH2LB
RH4B
RY2S, RY22S
RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
GT5Y
RY4S, RY42S, RU4S, RU42S, RY2KS, RM2S,
GT5Y
PC Board
For Panel Mounted Timers
SR6P-M08G
SR
F-28
8-pin
2
SR6P-M11G
GE1A; RTE-P1; GT3 (8-pin);
M3.5 Screw
11-pin
RTE-P2; GT3 (11-pin)
For relay mounting accessories, see page F-29.
F-2
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
Selection Guide
Specifications
Specifications
SU, SR, SH, SM, SY
Rated Insulation Voltage
300V; except SH1B, SU and SY4S-62: 250V
Rated Current
SU2/SR/SH/SM: 10A, SY: 7A, SU4: 6A with RU4,
SU4: 10A with RU2 (SH1B: 7A)
Insulation Resistance
100MΩ minimum
Dielectric Strength
2,000V AC, 1 minute
Material Grade
UL94V-0
Terminal Torque
3.5mm Screws, 9-11.5 in•lbs
3mm screws, 5.5-9 in•lbs
1. * Applicable to DIN rail sockets only.
UL Recognized
File No. E62437
CSA Certified
File No.LR35144
F
Sockets
File No. BL950813332307
SJ, SQ
SJ Series
Specifications
Rated Current
SJ1S: 12A Max; SJ2S: 8A Max
SQ Series
SQ1V: 12A Max; SQ2V: 10A Max
Rated Voltage
250V
300V
Applicable Wire
2x #14 (2.5mm2)
2x #14 (2.5mm2)
Applicable Crimping Terminal
2mm2 x 2
1.5mm2 x 2
Terminal Torque
0.6 to 1.0Nm
1.0Nm Max
Screw Size
M3 Slotted Phillip Captive Screw
M3 Slotted Phillip Captive Screw
Dielectric Strength (Coil/Contact)
4,000VAC
3,000VAC
Insulation Resistance
≥100 MΩ Minimum
≥100 MΩ Minimum
Operating Temperature
-40 to 70°C (no freezing)
-25 to +85°C
Operating Humidity
5~85% RH (no condensation)
45~85% RH
CSA Certified
File No.LR84913
UL Recognized
File No. E62437
UL Recognized
File No. E141060
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-3
Sockets
Selection Guide
Hold-Down Springs and Clips Selection Guide
DIN Rail Snap/Surface-Mount Sockets
Socket Part No.
SU2S-11L
SU4S-11L
SR2P-05
SR2P-05C
SR2P-06
SR3P-05
SR3P-05C
Sockets
F
Applicable Relays, Timer
Hold-Down Pullover Spring
Hold-Down Clip
(side latch)
Hold-Down Clip
(top latch)
RM2S, RU2, GT5Y-2
SY4S-51F1
SFA-202
SFA-101
RY4S, RY42S, RU4, RU42,
GT5Y, RY2KS, RM2S
SY4S-51F1
SFA-202
SFA-101
RR2P
SR2B-02F1
SFA-203
—
RTE-P1, GT3, GT5P
—
SFA-203
—
RR2P
SR2B-02F1
SFA-202
—
GT3 (8-pin), RTE-P1, GT5P
—
SFA-202
—
RR3PA
SR3B-02F1
SFA-203
—
RR2KP
SR3P-06F3
SFA-203
—
RTE-P2, GT3 (11-pin)
—
SFA-203
—
RR3PA
SR3B-02F1
SFA-202
—
SR3P-06
RR2KP
SR3P-06F3
SFA-202
—
RTE-P2, GT3 (11-pin)
—
SFA-202
—
SR3B-05
RR1BA, RR2BA, RR3B, RTE-B
SR3B-02F1
SFA-202
—
SH1B-05
SH1B-05C
RH1B
SY2S-02F1
SFA-202
SFA-101
SH2B-05
SH2B-05C
RH2B
SY4S-02F1
SFA-202
SFA-101
SH3B-05
SH3B-05C
RH3B, RH2LB
SH3B-05F1
SFA-202
SFA-101
SH4B-05
SH4B-05C
RH4B
SH4B-02F1
SFA-202
SFA-101
SY2S-05
SY2S-05C
RY2S, RY22S
SY2S-02F1
SFA-202
SFA-101
RY4S, RY42S, RU4, RU42,
RM2S
SY4S-51F1
SFA-202
SFA-101
SY4S-05
SY4S-05C
RY2KS, GT5Y
(SY4S-51F3)
SFA-202
SM2S
RM2S, RU2
SY4S-51F1
SFA-202
SJ1S
SJ2S
RQ1S
RJ2S
SJ9Z-C
SQ1S
SQ2S
RQ1V
RQ2V
SQ9Z-C
SFA-101
1. Hold-down springs work in conjunction with hold-down spring anchors included with DIN rail sockets.
2. When mounting relays with a check button onto panel mount or PC board mount sockets, use the hold-down spring shown in parenthesis. Hold-down
springs for relays with check buttons are not available for SR2P-51.
3. For close mounting of panel mount or PC mount sockets, use hold-down clips rather than hold-down springs.
4. SFA-101, SFA-202 and SFA-302 come in pairs.
SR2B-02F1
SY4S-51F1
F-4
SR3B-02F1
SY4S-51F3
www.idec.com
SH3B-05F1
SY4S-02F1
SR3P-01F1
SR3P-06F3
SH4B-02F1
SY2S-02F1
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
Selection Guide
Panel and PC Board Mount Sockets
Socket Part No.
SR2P-51
SR3P-51
Applicable Relays, Timer
Hold-Down Pullover Spring
Hold-Down Clip
(side latch)
Hold-Down Clip
(top latch)
RR2P
SR3P-01F1
—
—
GT3 (8-pin), RTE-P1
—
SFA-402
—
RR3PA
SR3P-01F1
—
—
SR3P-51F3
GT3 (11-pin), RTE-P2
—
SFA-402
—
SR3B-51
RR1BA, RR2BA,
RR3B, RTE-B
SR3B-02F1
—
—
SH1B-51
SH1B-62
RH1B
SY4S-51F1
—
SFA-301
SFA-302
SH2B-51
RH2B
SY4S-51F1
(SY4S-02F1)
—
SFA-301
SFA-302
SH2B-62
RH2B
SY4S-51F1
(SY4S-02F1)
—
—
SH3B-51
SH3B-62
RH3B, RH2LB
SY4S-51F1
(SY4S-02F1)
—
SFA-301
SFA-302
SH4B-51
SH4B-62
RH4B
SY4S-51F1
(SH4B-02F1)
—
SFA-301
SFA-302
SY2S-51
SY2S-61
RY2S, RY22S
SY4S-51F1
—
SFA-301
SFA-302
RY4S, RY42S
SY4S-51F1
(SY4S-02F1)
—
SFA-301
SFA-302
RY2KS
SY4S-51F1
(SY4S-02F3)
SFA-302
—
GT5Y
—
SFA-302
—
RY4S, RY42S, RM2S
SY4S-51F1
(SY4S-02F1)
—
—
RY2KS
SY4S-51F1
(SY4S-02F3)
—
—
SY4S-51
SY4S-61
SY4S-62 *
—
F
Sockets
RR2KP
* Does not accept hold down clips
SFA-202
SFA-302
SFA-101
SFA-402
SFA-301
www.idec.com
SFA-203
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-5
Sockets
SU Series: DIN Rail Snap-Mount
SU Series: DIN Rail Snap-Mount Sockets
SU2S-11L
Style
SU4S-11L
Style
14-blade DIN-mount/surface mount
Terminal
Spring clamp terminals
Terminal
Spring clamp terminals
Wire Size
24-16 AWG
Wire Size
24-16 AWG
Electrical Rating
10A
Electrical Rating
6A (using RU4), 10A (using RU2)
Compatible Relay
RU2, RM2
Compatible Relay
RY4S, RY42S, RU4, RU42S, RY2KS, RM2S
Compatible Timer
GT5Y-2
Compatible Timer
GT5Y
Hold-Down Clip
SFA-101 (top latch), SFA-202 (side latch)
Hold-Down Clip
SFA-101 (top latch), SFA-202 (side latch)
Inside the Cable Ports
1. On the SU2S, wires or ferrules cannot be connected to terminals 2, 3,
6, 7, 10 or 11 because neither springs nor conductive brackets are
installed in these terminals.
2. For socket mounting accessories, see page F-29.
Sockets
Inside the Cable Ports
Terminal Arrangement (top view)
SU2S-11L
Dimensions
SU4S-11L
Center of Relay-mounting area
11
10
9
12
11 10
9
8
7
6
5
8
7
6
5
4
3
2
1
4
3
2
1
13
14
80
12
31
13
37.5
14
28.8
Parts
Screwdriver Ports
Wire
Ports
Wire
Ports
Wire
Ports
➃
Wire
Ports
➄ ➅
32
35.3
Marking Plate
Spring slots for SFA-101:
➀➁➄➅
4.4
F
8-blade DIN-mount/surface mount
Spring slots for SFA-202:
➁➂➃➄
C
NO
NC
Terminal Terminal Terminal
F-6
➀ ➁
➂
Coil
Terminal
Clamp
www.idec.com
Panel Cutout for Surface Mounting
24
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SU Series: DIN Rail Snap-Mount
SU Series: General Instructions
Wiring Instructions
Applicable Wires
Wire
Size
Stranded wire
0.2 to 1.25 mm2 or AWG24 to 16
Solid wire
0.2 to 1.5 mm2 or AWG24 to 16
Wire insulation diameter
ø3.15mm maximum
1. Strip the wire insulation 9 to 10mm from the end.
2. In applications using ferrules for stranded wires, choose
the ferrule listed in table below. Make sure that an insulation sheath is applied when using the ferrules. When using
stranded wires without ferrules, make sure that the core
wires have not been loosened.
3. Two cable ports are provided for each terminal.
9 to 10mm
A - B sec
Screwdriver Ports
Incorrect
Correct
Incorrect
Incorrect
Direction of Screwdriver Tip
Note: Two cable ports are provided for each terminal.
B
1. Insert the optional screwdriver
(BC1S-SDO) or an applicable
screwdriver into the squareshaped port as shown on the right,
until the screwdriver tip touches
the bottom of the spring.
Manufacturer
24
A10.25-12BU
Phoenix Contact
_
22
A10.34-8TQ
Phoenix Contact
A10.5-8WH
20
A10.5-10WH
TE0.5
Phoenix Contact
Nichifu Co. Ltd
For wiring, use the optional screwdriver (BC1S-SDO) or the
following applicable screwdriver.
F
Sockets
Type
AWG
0.2
0.5
Stopper
A
Wire Ports for Terminal 9
Wire Ports for Terminal 10
2. Push in the screwdriver until it
touches the bottom of the port.
The wire port is now open, and the
screwdriver is held in place. The
screwdriver will not come off even
if you release your hand.
Applicable Ferrules
Applicable Wire (stranded)
mm2
Wire Port
3. While the screwdriver is
retained in the port, insert the wire
or ferrule into the round-shaped
wire port. Each wire port can
accommodate one wire or ferrule.
When connecting two wires to one
terminal, use the adjoining port of
the same terminal.
4. Pull out the screwdriver. The
connection is now complete.
Safety Precautions
Installing the Marking Plate
(Dimensions in mm)
7to
ø 2.5
13
º
0.4
2.5
Because of its removable structure, the marking plate may have fallen from
the socket or become loose in delivery. Make sure that the marking plate is
securely installed before starting operation. The marking plate protects the
conductive portion of the socket, located under the marking plate, by preventing metal fragments or pieces of wire from dropping inside. Should any such
fragments enter the socket, they may cause fire hazard, damage, or malfunction.
Jumper Ports
Marking Plate
Marking Instructions
Write markings on the SU sockets using an oil-based marker, or glue printed
mylar on the marking surface. The size of the printed mylar can be 8 x 9mm
maximum.
Marking Surface
8.0
9.0
8.0
Marking Plate
www.idec.com
No marking plate
Loose fitting
plate ribs
(on both sides)
Installed securely
Note: For installation of optional
p
jumper,
j p
see the instruction sheet provided
with the jumper.
r Jumper
Inserting Screwdriver into the Wire Ports
Maximum size of
printed mylar
Position of printed
mylar on the marking
surface
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-7
Sockets
SU Series: DIN Rail Snap-Mount
SU Series: SU9Z-J5 Jumper Installation Instructions
SU9Z-J5 Jumper for SU2S-11L and SU4S-11L
The SU9Z-J5 is used to install five sockets. When installing less than five
sockets cut the jumper according to the instructions listed to the right.
The SU9Z-J5 jumper is for coil terminals only.
SU9Z-95 Jumper
Rated Current
Material
Installing Two, Three or Four SU Sockets on the SU9Z-J5
Jumper
As shown below, slide the jumper in the sheath so that the jumper aligns with
the center of the sheath.
Jumper off center
Jumper on center
3A
Conductor
Nickel-plated brass
Sheath
ABS resin
With the sheath properly installed on the jumper, cut the sheath and
jumper at the points shown below, using cutting pliers. Referring to the
drawing on the right, make sure that the sheath and jumper are cut
within the cutting area. Dispose of unused portions according to local
waste disposal requirements.
Installation
Z
Y
Loosen the marking plate on the socket.
Shea
X
Jump
Shea
Cutting Area C
A
A: Loose fitting
B
Cutting Area D
Cutting Area in Detail
CD
B: Installed securely
Qty
F
2 Sockets
Sockets
2 Sockets
3 Sockets
4 Sockets
Ribs
Cutting Area
Discard
2
A, C
Y
1
A, B
X
1
D
Z
After cutting the jumper and sheath, slide the jumper as shown below, so that
the ends of the jumper ar e not exposed.
Grooves for marking plate ribs
(on both sides)
Alignment
Jumper Wiring to Six or More SU Sockets
Making sure that the SU9Z-J5 jumper is correctly aligned, insert the blades
into the ports in the groove of the SU sockets.
To jumper wire six or more SU sockets, connect five sockets using whole
jumpers and the remaining sockets using a cut jumper. Then connect the two
terminals on adjoining sockets using an applicable wire (see table below).
Incorrect
Correct
Proper wire
Insertion Direction
Jumper port
for terminal 13
Jumper port
for terminal 14
Wire
Blade
Jumper Groove
Size
Stranded wire
0.2 to 1.25 mm2
Solid wire
0.2 to 1.5 mm2
AWG
24 to 16
1. Use a wire with cable insulation diameter of ø3.15mm
maximum.
2. Strip the cable insulation 9 to 10mm from the end.
Jumper
Install Jumper Securely
Press down the marking plate to secure the jumper. The jumper installation is
now complete.
Safety Precautions
Turn off the power to the SU9Z-J5 jumper before starting installation,
removal, wiring, maintenance, or inspection of the jumper. Failure to turn
power off may cause an electrical shock or fire hazard.
To avoid a short circuit due to incorrect wiring, confirm which terminals are
connected to the jumper before beginning wiring.
F-8
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SJ Series: DIN Rail Snap-Mount
SJ Series: General Information
SJ1S-05B
Style
5 -blade snap mount/surface mount
Terminal/Torque
0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
250V, 12A
Compatible Relay
RJ1S
Compatible Timer
N/A
Hold-Down Spring
N/A
Replacement Locking Lever
SJ9Z-C
F
5-blade, snap mount/surface mount
Terminal/Torque
0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
250V, 12A
Compatible Relay
RJ1S
Compatible Timer
N/A
Hold-Down Spring
N/A
Replacement Locking Lever
SJ9Z-C
SJ2S-05B
Style
Sockets
SJ1S-07L Fingersafe
Style
8-blade, snap mount/surface mount
Terminal/Torque
0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
250V, 8A
Compatible Relay
RJ2S
Compatible Timer
N/A
Hold-Down Spring
N/A
Replacement Locking Lever
SJ9Z-C
All dimensions are in mm.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-9
Sockets
SJ/SQ Series: DIN Rail Snap-Mount
SJ2S-07L Fingersafe
Style
8-blade snap mount/surface mount
Terminal/Torque
0.6 - 1.0N•m (Maximum 1.2N•m)
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
250V, 8A
Compatible Relay
RJ2S
Compatible Timer
N/A
Hold-Down Spring
N/A
Replacement Locking Lever
SJ9Z-C
All dimensions are in mm.
SQ Series: General Information
Sockets
F
SQ1V-07B Fingersafe
Style
5-pin, snap mount/surface mount
Terminal/Torque
1.0N•m Maximum
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
300V, 12A
Compatible Relay
RQ1V-CM
Replacement Locking Lever
SQ9Z-C
Replacement Marking Plate
SQ9Z-P
Plug-in LED/Diode (6-24VDC)
SQ9Z-LD
Plug-in LED/RC (120/240VAC)
SQ9Z-LR
SQ2V-07B Fingersafe
Style
8-pin, snap mount/surface mount
Terminal/Torque
1.0N•m Maximum
Wire Size
Maximum up to 2 - #14 AWG
Electrical Rating
300V, 8A
Compatible Relay
RQ2V, RQ1V-CH
Replacement Locking Lever
SQ9Z-C
Replacement Marking Plate
SQ9Z-P
Plug-in LED/Diode (6-24VDC)
SQ9Z-LD
Plug-in LED/RC (120/240VAC)
SQ9Z-LR
All dimensions are in mm.
F-10
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SR Series: DIN Rail Snap-Mount
SR Series: DIN Rail Snap-Mount Sockets
SR2P Sockets
32 when
using BAA
36
8
300V, 10A
3
RR2P
Compatible Timer
RTE-P1, GT3 (8-pin), GT5P, GE1A
Hold-Down Spring
SR2B-02F1 (for RR2P)
Hold-Down Clip
SFA-203 (for timers only, except GE1A)
300V, 10A
Compatible Timer
RTE-P1, GT3 (8-pin), GT5P, GE1A
Hold-Down Spring
SR2B-02F1 (for RR2P)
Hold-Down Clip
SFA-203 (for timers only, except GE1A)
7
7.9max.
ø3.6min.
Terminal
Arrangement
DIN Rail (BAA)
5
4
6
3
7
2
8
1
2-ø4.2 Mounting Hole
(M4 screw hole)
5
21.5
29
25.5 when
using BAA
Electrical Rating
300V, 10A
Compatible Relay
RR2P
Compatible Timer
RTE-P1, GT3 (8-pin), GT5P, GE1A
Hold-Down Spring
SR2B-02F1 (for RR2P)
Hold-Down Clip
SFA-202 (for timers only, except GE1A)
1
ø4.2
33
Mounting
Hole
6
5
4
3
7
8
1
2
33
4.9max.
22
5min.
ø3.6min. (TOP VIEW)
18
7.9max.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
2
8
Terminal
Arrangement
DIN Rail (BAA)
ø25
Maximum up to 2–#12AWG
7
(cannot use ring terminal)
2-ø4.2 Mounting Hole
(M4 screw hole)
M3.5 Screw
60
Wire Size
3
30
8-pin octal, snap-mount/surface mount
M3.5 screws with captive wire clamp
(9 - 11.5 in•lbs)
4
(TOP VIEW)
40
8
Terminal/Torque
5
6
29
4.
1
SR2P-06
Style
20
33.5 when
using BAA
36
2.2
RR2P
1
(TOP VIEW)
2
Compatible Relay
2
8
F
58
Electrical Rating
7
Sockets
Maximum up to 2–#12AWG
3
5min.
28.5
M3.5 screws with captive wire clamp,
fingersafe (9 - 11.5 in•lbs)
Wire Size
16.5
Mounting
Hole
29
SR2P-05C Fingersafe
8-pin octal, snap-mount/surface mount
Style
Terminal/Torque
4.4max.
ø4.2
Compatible Relay
4
52
Electrical Rating
5
6
29
3
Maximum up to 2–#12AWG
33
Wire Size
2-ø4.2 Mounting Hole
(M4 screw hole)
ø25
Terminal/Torque
M3.5 screws with captive wire clamp
(9 - 11.5 in•lbs)
Terminal
Arrangement
DIN Rail (BAA)
M3.5 Screw
8-pin octal, snap-mount/surface mount
52
SR2P-05
Style
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
All dimensions are in mm.
F-11
Sockets
SR Series: DIN Rail Snap-Mount
SR3P Sockets
32 when
using BAA
42
8
11-pin octal, snap-mount/surface mount
Terminal/Torque
M3.5 screws with captive wire clamp
Wire Size
Maximum up to 2–#12AWG
Electrical Rating
300V, 10A
Compatible Relay
RR3PA, RR2KP
DIN Rail (BAA)
M3.5 Screw
2-ø4.2 Mounting Hole
(M4 screw hole)
(9 - 11.5 in•lbs)
Compatible Timer
GT3 (11-pin), RTE-P2
Hold-Down Spring
SR3B-02F1 for RR3P; SR3P-06F3 for RR2KP
Hold-Down Clip
SFA-203 (Timers)
Terminal
Arrangement
6
7
5
4
52
33
ø27
8
34
9
4.4max.
ø4.2
34
5min.
16.5
Mounting
Hole
3
SR3P-05
Style
20
3
10 11
2
1
(TOP VIEW)
ø3.6min.
7.9max.
28.5
SR3P-05C Fingersafe
Style
11-pin octal, snap-mount/surface mount
300V, 10A
Compatible Relay
RR3PA, *RR2KP (*latching relay)
Compatible Timer
GT3 (11-pin), RTE-P2
Hold-Down Spring
SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP
Hold-Down Clip
SFA-203 (Timers)
6
5
8
4
9
3
ø
5
7
58
Maximum up to 2–#12AWG
Electrical Rating
2-ø4.2 Mounting Hole
(M4 screw hole)
1
0
1
1
1
Terminal/Torque
9
2
1
(TOP VIEW)
2
21.5
59
M3.5 screws with captive wire clamp
25.5 when
using BAA
8
(9 - 11.5 in•lbs)
(cannot use ring terminal)
Terminal
Arrangement
DIN Rail (BAA)
M3.5 Screw
2-ø4.2 Mounting Hole
(M4 screw hole)
Electrical Rating
300V, 10A
Compatible Relay
RR3PA, *RR2KP (*latching relay)
ø4.2
Compatible Timer
GT3 (11-pin), RTE-P2
Mounting
Hole
Hold-Down Spring
SR3B-02F1 for RR3PA; SR3P-06F3 for RR2KP
Hold-Down Clip
SFA-202 (Timers)
60
ø27
Maximum up to 2–#12AWG
www.idec.com
3
10 11
Wire Size
F-12
5
4
8
30
11-pin octal, snap-mount/surface mount
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
6
7
34
ø4
.2
34
SR3P-06
Style
Terminal
Arrangement
DIN Rail (BAA)
M3.5 screws with captive wire clamp,
fingersafe (9 - 11.5 in•lbs)
Wire Size
33.5 when
using BAA
7
2.2
Terminal/Torque
42
33
1
Sockets
F
8
7
6
5
4
2
3
33
4.9max.
18
22
5min.
ø3.6min.
9
10 11
1
(TOP VIEW)
7.9max.
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SR Series: DIN Rail Snap-Mount
SR3B Sockets
When using
BAA/BAP: 28.5
36
8
M3.5 Terminal
Screw
2-ø4.2 Mounting Holes
(or M4 Tapped Holes)
4.2
6
5
4
3
2
1
37
56
11-blade, snap-mount/surface mount
76
SR3B-05
Style
Terminal Arrangement
DIN Rail
(BAA/BAP)
A
B
Terminal/Torque
M3.5 screws with captive wire clamp
Wire Size
Maximum up to 2–#12AWG
4.4 max.
5.5 min.
(9 - 11.5 in•lbs)
9
8
7
2
(Top View)
Electrical Rating
300V, 15A (10A)* (*denotes CSA rating)
Compatible Relay
RR1BA, RR2BA, RR3B
Compatible Timer
RTE-B
Hold-Down Spring
SR3B-02F1 (relays)
Hold-Down Clip
SFA-202 (relays and timers)
37
43
14.5
7.9 max.
ø3.6 min.
25
All dimensions are in mm.
F
Sockets
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-13
Sockets
SH Series: DIN Rail Snap-Mount
SH Series: DIN Rail Snap-Mount Sockets
SH1B Sockets
When using
BAA/BAP: 28.5
17
8
Terminal/Torque
Wire Size
Maximum up to 2–#12AWG
Electrical Rating
250V, 10A
Compatible Relay
RH1B
Hold-Down Spring
SY2S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
Maximum up to 2–#12AWG
Electrical Rating
250V, 10A
Compatible Relay
RH1B
Hold-Down Spring
SY2S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-14
www.idec.com
1
13
9
47
(Top View)
14.5
20
14
4 max.
4.4 max.
16
ø3.2 min.
ø3.6 min.
25
7.9 max.
5.9 max.
(For terminals 1, 5, and 9)
SH1B-05C Fingersafe
Style
5-blade, snap-mount/surface mount
Wire Size
5
4.8 min.
5.5 min.
M3 Terminal
Screw
7
(For terminals 13 and 14)
When using
BAA/BAP: 33
M3.5 Terminal
Screw
25
DIN Rail
(BAA/BAP)
Terminal Arrangement
5
ø5
2-ø4.2 Mounting Holes
(or M4 Tapped Holes)
1
48
4.2
69
Terminal/Torque
Terminal Arrangement
2-ø4.2 Mounting Holes
(or M4 Tapped Holes)
16
17
(Coil) M3 screws/(5.5 - 9 in•lbs) (contact)
M3.5 screws with captive wire clamp,
fingersafe (9 - 11.5 in•lbs)
DIN Rail
(BAA/BAP)
18
4.2
67
(Coil) M3 screws/(5.5 - 9 in•lbs) (contact)
M3.5 screws (9 - 11.5 in•lbs)
with captive wire clamp
16
M3 Terminal
Screw
14
13
9
16
1.7
Sockets
F
5-blade, snap-mount/surface mount
2.5
SH1B-05
Style
M3.5 Terminal
Screw
20
18.7
Ring type crimping
terminals cannot be used.
(Top View)
29.5
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SH Series: DIN Rail Snap-Mount
SH2B Sockets
When using
BAA/BAP: 28.5
22
8
Wire Size
Maximum up to 2–#12AWG
Electrical Rating
300V, 10A
Compatible Relay
RH2B
Hold-Down Spring
SY4S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
DIN Rail
(BAA/BAP)
Terminal Arrangement
2-ø4.2 Mounting Holes
(or M4 Tapped Holes)
47
M3.5 screws with captive wire clamp
(9 - 11.5 in•lbs)
8
5
4
1
14
13
12
9
26
4.4 max.
2.5
Terminal/Torque
18
4.2
8-blade, snap-mount/surface mount
67
SH2B-05
Style
M3.5 Terminal
Screw
26
14.5
30
25
5.5 min.
(Top View)
7.9 max.
ø3.6 min.
F
SH2B-05C Fingersafe
Style
8-blade, snap-mount/surface mount
Maximum up to 2–#12AWG
Electrical Rating
300V, 10A
RH2B
Hold-Down Spring
SY4S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
ø5
DIN Rail
(BAA/BAP)
Terminal Arrangement
2-ø4.2 Mounting Holes
(or M4 Tapped Holes)
8
5
4
1
14
13
12
9
26
1.7
Compatible Relay
25
49
Wire Size
M3.5 Terminal
Screw
4.2
M3.5 screws with captive wire clamp, fingersafe (9 - 11.5 in•lbs)
69
Terminal/Torque
7
26
30
18.7
29.5
Ring type crimping
terminals cannot be used.
(Top View)
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-15
Sockets
When using
BAA/BAP: 33
22
Sockets
SH Series: DIN Rail Snap-Mount
SH3B Sockets
18
Maximum up to 2–#12AWG
Electrical Rating
300V, 10A
M3.5 Screw
Terminal
Arrangement
DIN Rail (BAA)
2-ø4.2 Mounting Hole
(M4 screw hole)
8
6
5
4
2
1
47
Wire Size
Compatible Relay
8
M3.5 screws with captive wire clamp
(9 - 11.5 in•lbs)
4.2
Terminal/Torque
28.5 when
using BAA
32
11-blade, snap-mount/surface mount
67
SH3B-05
Style
36
4.4max.
RH3B, RH2LB
5.5min.
14
12
SH3B-05F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
36
2.5
Hold-Down Spring
14.5
25
40
13
10
9
(TOP VIEW)
7.9max.
ø3.6min.
SH3B-05C Fingersafe
Style
11-blade, snap-mount/surface mount
Terminal/Torque
7
M3.5 screws with captive wire clamp,
fingersafe (9 - 11.5 in•lbs)
8
44
Wire Size
Maximum up to 2–#12AWG
24
14
4
2
RH3B, RH2LB
1
22
A2
Hold-Down Clip
SH3B-05F1
SFA-101 (top notch), SFA-202 (side notch)
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-16
www.idec.com
2-ø4.2 Mounting Hole
(M4 screw hole)
10
36
40
8
6
5
4
2
1
36
14
13
21
41
12
Terminal
Arrangement
A1
14
1.7
Hold-Down Spring
ø5
12
49
Compatible Relay
25
5
4.2
300V, 10A
M3.5 Screw
6
42
Electrical Rating
33 when
using BAA
32
DIN Rail (BAA)
Sockets
F
12
13
10
9
11
(cannot use ring terminal)
9
(TOP VIEW)
18.7
29.5
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SH Series: DIN Rail Snap-Mount
SH4B Sockets
28.5 when
using BAA
42
8
14-blade, snap-mount/surface mount
Wire Size
Maximum up to 2–#12AWG
Electrical Rating
300V, 10A
Compatible Relay
RH4B
Hold-Down Spring
SH4B-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
2-ø4.2 Mounting Hole
(M4 screw hole)
8
4
7
3
6
5
2
1
11
10
47
M3.5 screws with captive wire clamp
(9 - 11.5 in•lbs)
Terminal
Arrangement
DIN Rail (BAA)
4.2
Terminal/Torque
18
M3.5 Screw
67
SH4B-05
Style
46
4.4max.
5.5min.
14
13
12
ø3.6min.
2.5
46
14.5
25
50
9
(TOP VIEW)
7.9max.
F
Sockets
SH4B-05C Fingersafe
Style
14-blade, snap-mount/surface mount
Terminal/Torque
44
8
7
6
34
24
14
3
2
1
32
22
12
4
RH4B
Hold-Down Spring
SH4B-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
ø5
2-ø4.2 Mounting Hole
(M4 screw hole)
8
4
7
3
6
5
2
1
11
10
49
300V, 10A
Compatible Relay
69
Electrical Rating
Terminal
Arrangement
DIN Rail (BAA)
5
4.2
42
Maximum up to 2–#12AWG
25
7
M3.5 screws with captive wire clamp,
fingersafe (9 - 11.5 in•lbs)
Wire Size
33 when
using BAA
42
A2
13
41
31
11
21
10
1.7
12
46
A1
14
46
14
11
9
12
18.7
29.5
(cannot use ring terminal)
13
9
(TOP VIEW)
50
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-17
Sockets
SY Series: DIN Rail Snap-Mount
SY Series: DIN Rail Snap-Mount Sockets
SY2S Sockets
6
8-blade, snap-mount/surface mount
Maximum up to 2–#14AWG
Electrical Rating
300V, 7A
Compatible Relay
RY2S, RY22S
Hold-Down Spring
SY2S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
8
5
4
1
14
13
12
9
45
Wire Size
2-ø4.2 Mounting Hole
(M4 screw hole)
16
4.2
M3 screws with captive wire clamp
(5.5 - 9 in•lbs)
Terminal
Arrangement
DIN Rail (BAA)
M3 Screw
62
Terminal/Torque
18
4max.
16
4.8min.
ø3.2min.
14.5
5.9max.
25
20
(TOP VIEW)
Sockets
F
28.5 when
using BAA
17
2
SY2S-05
Style
32.5 when
using BAA
Terminal/Torque
17.2
6
M3 screws with captive wire clamp,
fingersafe (5.5 - 9 in•lbs)
8
5
44
14
1
4
300V, 7A
Compatible Relay
RY2S, RY22S
Hold-Down Spring
SY2S-02F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side notch)
12
4.2
Electrical Rating
42
46
Maximum up to 2–#14AWG
A2
F-18
www.idec.com
13
11
12
1.6
8
5
4
1
14
13
12
9
16
2
41
2-ø4.2 Mounting Hole
(M4 screw hole)
A1
14
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
ø5
64
Wire Size
Terminal
Arrangement
25
M3 Screw
DIN Rail (BAA)
SY2S-05C Fingersafe
Style
8-blade, snap-mount/surface mount
16
20
(TOP VIEW)
9
18.2
29
(cannot use ring terminal)
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SY Series: DIN Rail Snap-Mount
SY4S Sockets
using BAA
6
18
M3 screw with captive wire clamp
(5.5 - 9 in•lbs)
300V, 7A
Compatible Relay
RY4S, RY42S, RU4S, RU42S, RM2S,
*RY2KS, (*latching relay)
2-ø4.2 Mounting Hole
(M4 screw hole)
8
7 6
5
4
3 2
1
45
Maximum up to 2–#14AWG
Electrical Rating
Terminal
Arrangement
DIN Rail (BAA)
M3 Screw
62
Wire Size
Compatible Timer
0.7
14-blade, snap-mount/surface mount
26
4.2
Terminal/Torque
28.5 when
30
4max.
GT5Y
18.5
Hold-Down Spring
SY4S-51F1 for all relays; SY4S-51F3 for
RY2KS only
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side
notch) for all relays and timers
26
14
4.8min.
ø3.2min.
3
SY4S-05
Style
13
12 11 10 9
(TOP VIEW)
5.9max.
25
F
Sockets
Terminal/Torque
M3 screw with captive wire clamp,
fingersafe (5.5 - 9 in•lbs)
Wire Size
Maximum up to 2–#14AWG
30
M3 Screw
7
8
34
44
4
Electrical Rating
300V, 7A
Compatible Relay
RY4S, RY42S, RM2S, RU4S, RU42S,
*RY2KS, (*latching relay)
Compatible Timer
GT5Y
Hold-Down Spring
SY4S-51F1 for all relays; SY4S-51F3 for
RY2KS only
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side
notch) for GT5Y timer and relays
25
6
32
5
14
2
22
1
ø5.5
18
Terminal
Arrangement
2-ø4.2 Mounting Hole
(M4 screw hole)
8
7 6
5
4
3 2
1
12
64
46
4.2
42
6
24
3
DIN Rail (BAA)
32.5 when
using BAA
SY4S-05C Fingersafe
Style
14-blade, snap-mount/surface mount
26
14
A2
1.6
12
12 11 10 9
13
31
11
21
10
11
9
2.0
41
13
A1
14
(TOP VIEW)
(cannot use ring terminal)
26
18.2
29
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-19
Sockets
SM Series: DIN Rail Snap-Mount
SM2S Sockets
Maximum up to 2–#14AWG
Electrical Rating
300V, 10A
Compatible Relay
RU2S, RM2S
Compatible Timer
—
Hold-Down Spring
SY4S-51F1
Hold-Down Clip
SFA-101 (top notch), SFA-202 (side
notch)
Terminal
Arrangement
DIN Rail (BAA)
M3 Screw
2-ø4.2 Mounting Hole
(M4 screw hole)
8
5
4
1
14
13
12
9
26
4max.
4.8min.
ø3.2min.
18.5
5.9max.
25
26
(TOP VIEW)
Sockets
F
18
45
Wire Size
6
4.2
M3 screw with captive wire clamp
(5.5 - 9 in•lbs)
3
Terminal/Torque
28.5 when
using BAA
30
0.7
8-blade, snap-mount/surface mount
62
SM2S-05
Style
Wire Size
Maximum up to 2–#14AWG
Electrical Rating
300V, 10A
Compatible Relay
RU2S, RM2S
M3 Screw
8
44
Compatible Timer
SFA-101 (top notch), SFA-202 (side
notch)
22
1
18
ø5.5
12
2-ø4.2 Mounting Hole
(M4 screw hole)
8
5
4
1
14
13
12
46
64
12
9
26
A1
14
1.6
Hold-Down Clip
32
5
14
2
A2
41
SY4S-51F1
24
3
Terminal
Arrangement
4.2
42
6
7
34
4
—
Hold-Down Spring
25
6
13
31
11
26
21
10
2
Terminal/Torque
M3 screw with captive wire clamp,
fingersafe (5.5 - 9 in•lbs)
30
DIN Rail (BAA)
32.5 when
using BAA
SM2S-05C Fingersafe
Style
8-blade, snap-mount/surface mount
11
(TOP VIEW)
9
18.2
29
(cannot use ring terminal)
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-20
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SR Series: Panel Mount
SR Series: Panel Mount Sockets
1
4
2
5
3
6
7
8
9
A
6.5
3
22
Solder
Electrical Rating
300V, 10A
Compatible Relay
RR1BA, RR2BA, RR3B
Compatible Timer
RTE-B
Hold-Down Spring
SR3B-02F1 (for relays only)
(Bottom View)
(Tolerance ±0.3)
∗ When two or more sockets are
mounted side by side:
L = 38 (N – 1) + 35.5
N: No. of sockets mounted
3.5
35
2-ø3.5 Mounting Holes
(or M3 Tapped Holes)
5
1
8
0
4
3
6
2
ø3
38
ø29
Terminal Arrangement
7
8-pin octal, panel mount
Terminal
Solder
Electrical Rating
300V, 10A
Compatible Relay
RR2P
Compatible Timer
RTE-P1, GT3 (8-pin), GT5P
Hold-Down Spring
SR3P-01F1 (for relay only)
Hold-Down Clip
SFA-402 (for GT3 8-pin)
SFA-302 (for GT5P)
34
2.5
10 11
(Bottom View)
Panel
Surface
2.5
6
4.2
2-ø3.5 Mounting Holes
(or M3 Tapped Holes)
Terminal Arrangement
11-pin octal, panel mount
Terminal
Solder
Electrical Rating
300V, 10A
Compatible Relay
RR3PA, *RR2KP
(*latching relay)
Compatible Timer
GT3 (11-pin), RTE-P2
Hold-Down Spring
SR3P-01F1 for RR3PA
SR3P-51F3 for RR2KP
Hold-Down Clip
SFA-402 (for GT3 11-pin,
RTE-P2)
2
34
2.5
10 11
(Bottom View)
2.5
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
38
9
10
0
8
1 11
ø3
ø29
38
50
5 6 7
4
3
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F
Sockets
50
6
4.2
SR3P-51
Style
B
2-ø4.2 Mounting Holes
(M4 Tapped Holes)
38
Terminal
SR2P-51
Style
35.5∗
22
11-blade, panel mount
Panel
Surface
SR3B-51
Style
6.75
32.5
43
0.3
35
43
51.5
Terminal Arrangement
11.5 min.
11 max.
7.5
32
38
All dimensions are in mm.
F-21
Sockets
SH Series: Panel Mount
SH Series: Panel Mount Sockets
1
5
9
25.4
31
[18 (N–1) + 12.4] +0.5
0
Terminal Arrangement
25.6 +0.2
0
Panel Thickness:
1 to 2
3
(Bottom View)
11
5-blade, panel mount
Terminal
Solder
Electrical Rating
300V, 10A
Compatible Relay
RH1B
Hold-Down Spring
SY4S-51F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
18.7
3.5
N: No. of sockets mounted
5.4 min.∗
SH1B-51
Style
0.3
13 14
18
∗ 10.4 min. when using hold-down springs
2.4
12.2
31
[27 (N–1) + 21.4]
+0.5
0
Terminal Arrangement
1 4
5 8
9 12
+0.2
0
25.4
Panel Thickness:
1 to 2
25.6
Sockets
F
11
8-blade, panel mount
Terminal
Solder
Electrical Rating
300V, 10A
Compatible Relay
RH2B
Hold-Down Spring
SY4S-51F1
SY4S-02F1 for RH2B-4C
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
18.7
(Bottom View)
5.4 min.∗
3
27
0.3
13 14
SH2B-51
Style
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
3.5
21.2
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-22
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SH Series: Panel Mount
SH Series: Panel Mount Sockets, continued
[36 (N–1) + 30.4] +0.5
0
0.3
11
11-blade, panel mount
18.7
Terminal
Solder
Electrical Rating
300V, 10A
Compatible Relay
RH3B, *RH2LB
(*latching relay)
Hold-Down Spring
SY4S-51F1
SY4S-02F1 for RH3B-4C
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
3.5
30.2
F
Terminal Arrangement
1 2 3 4
5 6 7 8
9 10 11 12
Solder
Electrical Rating
300V, 10A
Compatible Relay
RH4B
Hold-Down Spring
SY4S-51F1, SY4S-02F1
Hold-Down Clip
SFA-301, SFA-302
11
18.7
0.3
3
14
(Bottom View)
5.4 min.∗
Terminal
45
+0.2
25.6 0
25.4
31
[45 (N–1) + 39.4] +0.5
0
13
14-blade, panel mount
Sockets
Panel Thickness:
1 to 2
SH4B-51
Style
14
(Bottom View)
5.4 min.∗
3
36
25.6
31
1 2 4
5 6 8
9 10 12
13
SH3B-51
Style
+0.2
0
Terminal Arrangement
25.4
Panel Thickness:
1 to 2
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
3.5
39.2
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-23
Sockets
SY Series: Panel Mount
SY Series: Panel Mount Sockets
Panel Thickness:
1 to 2
[18(N–1)+12.4] +0.5
0
Solder
Electrical Rating
300V, 7A
Compatible Relay
RY2S, RY22S
Hold-Down Spring
SY4S-51F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
3
0
25.6
13 14
(Bottom View)
5.4 min.∗
8-blade, panel mount
Terminal
1 4
5 8
9 12
25.4
18
0.3
31
SY2S-51
Style
+0.2
Terminal Arrangement
11
18.7
N: No. of sockets mounted
∗ 10.4 min. when husing hold-down springs
2.4
12.2
Terminal
Solder
Electrical Rating
300V, 7A
Compatible Relay
RY4S, RY42S, RM2S,
RY2KS, RU4S, RU2S,
RU42S
Compatible Timer
GT5Y
Hold-Down Spring
SY4S-51F1 for all
relays except;
SY4S-02F3 for RY2KS
relay
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
[27 (N–1) + 21.4] + 0.5
0
13
3
27
11
18.7
2.4
14
(Bottom View)
0
25.6
1 2 3 4
5 6 7 8
9 10 11 12
+0.2
Terminal Arrangement
5.4 min.∗
14-blade, panel mount
0.3
SY4S-51
Style
25.4
Panel Thickness:
1 to 2
31
Sockets
F
N: No. of sockets mounted
∗ 10.4 min. when using hold-down springs
21.2
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-24
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SH Series: PCB Mount
SH Series: PC Board Mount Sockets
15
Terminal
Solder/PCB mount
Electrical Rating
250V, 10A
Compatible Relay
RH1B
5.95
11.85
0.3
(Bottom View)
11
5-blade
4.4
31 min.∗
SH1B-62
Style
3
18 min.
4.7
6.95
31
25.4
1
5
9
13 14
18
6.8
3-ø2.4 holes
Terminal Arrangement
2
1.5
2-ø2 holes
(Tolerance ±0.1)
∗ 36 min. when using
hold-down springs
12.2
Hold-Down Spring SY4S-51F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
F
Terminal
Solder/PCB mount
Electrical Rating
300V, 10A
Compatible Relay
RH2B
Hold-Down Spring
SY4S-51F1, SY4S-02F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
5.65
10
(Bottom View)
11
15
2
6.6
3
21.2
15.5
14
29 min.∗ 12.5
8-blade
0.3
13
4.7
25.4
29
SH2B-62
Style
21.5 min.
2.85
1 4
5 8
9 12
8-ø2.4 holes
(Tolerance ±0.1)
∗ 34 min. when using
hold-down springs
36 min.
15
Terminal
Solder/PCB mount
Electrical Rating
300V, 10A
Compatible Relay
RH3B, *RH2LB
2
30.2
6.6
11
11-blade
10 10
14
(Bottom View)
31 min.∗
SH3B-62
Style
0.3
13
3
21.3
7.35
4.7
1 2 4
5 6 8
9 10 12
12.5
6.65
31
25.4
Terminal Arrangement
36
Sockets
Terminal Arrangement
11-ø2.4 holes
(Tolerance ±0.1)
∗ 36 min. when using
hold-down springs
(*latching relay)
Hold-Down Spring SY4S-51F1, SY4S-02F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
All dimensions are in mm.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-25
Sockets
SH/SY Series: PCB Mount
Terminal Arrangement
6.85
1 2 3 4
5 6 7 8
9 10 11 12
4.7
6.65
11
Terminal
Solder/ PCB mount
Electrical Rating
300V, 10A
Compatible Relay
RH4B
Hold-Down
Springs
SY4S-51F1, SH4B-02F1
Hold-Down Clip
SFA-301 (top notch),
SFA-302 (side notch)
2
6.6
15
14-blade
10 10 10
14
(Bottom View)
31 min.∗
SH4B-62
Style
0.3
13
3
45
45 min.
31.3
12.5
31
25.4
SH Series: PC Board Mount Sockets, continued
14-ø2.4 holes
∗ 36 min. when using
hold-down springs
39.2
(Tolerance ±0.1)
Sockets
F
Solder/PCB mount
Electrical Rating
300V, 7A
Compatible Relay
RY2S, RY22S
Hold-Down Spring SY4S-51F1
3
18
11
15
1.5
0.3
13 14
8-blade
Terminal
Hold-Down Clip
(Bottom View)
∗ 19.2 min. when using
hold-down springs
4.4
13.6 min.
9
16.8
1 4
5 8
9 12
14.2 min.∗
31
SY2S-61
Style
25.4
Terminal Arrangement
4.1
10.4
SY Series: PC Board Mount Sockets
8-ø2 holes
(Tolerance ±0.1)
12.2
SFA-301 (top notch),
SFA-302 (side notch)
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-26
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
SY Series: PCB Mount
SY Series: PC Mount Sockets, continued
13.2
13.8 min.
3
300V, 7A
Compatible Relay
RY4S, RY42S, RM2S,
*RY2KS, RU4S, RU42S, RU2S
(*latching relay)
9
16.8
(Bottom View)
11
Electrical Rating
Compatible Timer
27
Solder/PCB mount
1 2 3 4
5 6 7 8
9 10 1112
13
14
4.4
14.2 min.∗
14-blade
0.3
15
15-ø2 holes
1.4
Terminal
31
SY4S-61
Style
25.4
Terminal Arrangement
4.1
10.4
8.8
(Tolerance ±0.1)
∗ 19.2 min. when using
hold-down springs
1.5
21.2
GT5Y
Hold-Down Spring SY4S-51F1, SY4S-02F1
Hold-Down Clip
SFA-301 (top notch; except
GT5Y and RY2KS)
SFA-302 (side notch for all)
F
Sockets
13.2
8.2 min.∗∗
8.8
4.1
4.4
Solder/PCB mount
Electrical Rating
250V, 7A
Compatible Relay
RY4S, RY42S, RU4S,
RU42S, *RY2KS
(*latching relay)
Compatible Timer
GT5Y
Hold-Down Spring
SY4S-51F1, SY4S-51F3,
SY4S-51F4, *SY4S-02F1,
*SY4S-02F3
(*when mounting a relay
with check button)
21.2
(Bottom View)
3
11
15
1.5
9
15-ø2 holes
12.2 min.∗
Terminal
1.4
14-blade
1 2 3 4
5 6 7 8
9 10 1112
13
14
16.8
10.4
29
SY4S-62
Style
0.3
Terminal Arrangement
(Tolerance ±0.1)
∗ 17.2 min. when using a hold-down spring.
∗∗ 13.2 min. when using a hold-down spring for
the relay with check button.
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-27
Sockets
Other Sockets
SR Series: Socket for Panel Mounted Timers
8-M3.5
0.8~5mm
44.6
3.5max.
4
M3.5 screws with captive wire clamp
Electrical Rating
300V, 10A
Wire Size
Maximum up to 2-#12AWG
Compatible Timer
GT3 (8-pin), RTE-P1, GE1A
Hold-Down Spring
SY4S-02F1
1
8
7
7
8-pin
Terminal
5.6min.
ø3.6min.
6
6.9max.
2
SR6P-M08G
Style
5
30.4
44.6
3
9.8x3
80.5
F
11-M3.5
45
3.5max.
2
1
11
3
8
7
6
45
6.9max.
4
SR6P-M11G
Style
11-pin
Terminal
M3.5 screws with captive wire clamp
Electrical Rating
300V, 10A
Wire Size
Maximum up to 2-#12AWG
Compatible Timer
GT3 (11-pin), RTE-P2
Hold-Down Spring
------
30.5
92
5.8min.
ø3.6min.
5
34
Sockets
16.7
9 10
7
8.5x4
All dimensions are in mm.
1. For socket mounting accessories, see page F-29.
2. For hold-down clip/spring selections, see page F-4.
F-28
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
Accessories
Accessories
SA-203
18mm
5mm
Description
SA-204
SA-203
M4 screw
washer
hold-down
spring
Appearance
Use with
Part No.
Remarks
Aluminum
DIN Rail
(1 meter length)
All DIN rail sockets
BNDN1000
IDEC offers a low-profile DIN rail
(BNDN1000). The BNDN1000 is
designed to accommodate snapmount sockets. Made of durable
extruded aluminum, the BNDN-1000
measures 0.413 in height and 1.37
(35mm) in width (DIN standard).
Standard length is 39" (1,000mm).
DIN Rail
End Stop
DIN rail
BNL5
9.1 mm wide.
Surface Mount
End Connector
SY2S, SY4S, SR3B, SH1B,
SH2B, SH3B, SH4B
SA-203
For use on ends of socket groupings
when surface mounting.
SA-204
For use between adjoining sockets
when surface mounting.
Surface Mount
Connector
SY2S, SY4S, SR3B, SH1B,
SH2B, SH3B, SH4B
SA-405
For use between adjoining sockets
when surface mounting.
DIN Rail Spacer
All DIN rail sockets
SA-406
SY4S-51, SH2B-51
SA-402
11.42" length with 10 holes.
SY4S-51, SH2B-51
SA-403
23.33" length with 21 holes.
RH2B, RM2S, RY4S, RY42S,
RU4S, RU42S
RH-01
RY2S, RH1B
RH-03
Replacement HoldDown Spring Anchor
Horseshoe clip for all
DIN rail sockets except
SR*P-05(C)
Y778-011
For use with hold-down springs
(bale wire types).
or DIN rail mount sockets.
2 pieces included with each socket.
Hold-Down Spring for
SR*P-05(C)
Chair clip for SR*P-05(C)
Y703-102
For SR2P-05, SR2P-05C,
SR3P-05, SR3P-05C
F
Relay Holders
www.idec.com
For diagram, see next page.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-29
Sockets
Steel Mounting Plates
(for panel mount sockets)
Sockets
Instructions
Instructions
Mounting Snap-Mount Sockets
Snap-mount sockets are designed to mount on the BNDN-1000
Mount
mounting rail. The built-in mounting clip eliminates mounting hardware and reduces mounting time by 80%.
To mount see Figure 1. Place the end of the socket (end opposite of
mounting clip against the outer edge of the rail). Press the socket
down firmly until the clip snaps onto the mounting rail. To remove
see Figure 2. Pull out the mounting clip with a screwdriver, and lift
the socket.
Figure 1
Remove
For spacing between adjoining sockets, use the SA-406 DIN rail
spacer. Spacers are 0.195" wide. Spacing can be adjusted according to the number of spacers added. Spacers snap on and off easily
like snap-mount sockets.
Hold-Down Spring
To prevent side-to-side movement, use a BNL-5 end clip at each
end of every socket row.
Figure 2
Mounting Relay Holders
Sockets
F
RH-01 or -03
Mount directly onto panel boards in two alternate
positions: A and B (see Figure 1).
Figure 1
To mount the relay into the holder, hook the bottom
edge of the relay case (coil terminal side) onto the
relay holder (see Figure 2).
Push down until the relay snaps into place.
Figure 2
Mounting Hold-Down Springs
Take the two anchor clips (horseshoe / U-shaped
piece) that come with the socket and insert into
the slits on both sides of the socket. Make sure the
raised notches on the anchor clip face into the
socket.
Plug relay into socket
Insert the open ends of the hold-down spring into
either the first or second hole of the anchor clip.
The relay-spring combination will determine which
hole should be used.
Slide spring over relay.
F-30
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Sockets
Dimensions
Dimensions
Surface Mount Sockets (SH2B-02)
IDEC surface mount sockets (SH2B-02) are also designed to mount
individually or collectively on a flat surface without the use of a DIN
rail. Use the mounting screw between adjoining sockets and at the
outer ends of the row of sockets.
Dimension Table
Socket Part No.
Dimension A
SH2B-02
1.14"
A
A
A
1. Drawing is not to scale.
F
Snap-Mount Sockets
Sockets
Snap-mount sockets are designed to mount individually or collectively
without using a rail. Use a SA-405 connector or SA-204 connector
between adjoining sockets (see Figures 1 and 2). Use the SA-203 end
connector at the outer ends of each socket row when using the
SA-204 connector (see Figure 2).
Dimension Table
Socket Part No.
Dim. B
Dim. C
Dim. D
SY2S-05, SY2S-05C
0.669"
0.826"
0.866"
SY4S-05, SY4S-05C
1.024"
1.181"
1.220"
SR3B-05
1.496"
1.693"
1.732"
SH1B-05, SH1B-05C
0.630"
0.787"
0.827"
SH2B-05, SH2B-05C
1.024"
1.181"
1.220"
SH3B-05, SH3B-05C
1.417"
1.575"
1.614"
SH4B-05, SH4B-05C
1.811"
1.969"
2.008"
Using an SA-406 Connector
B
C
C
C
C
Using SA-203 or SA-204 Connectors
D
D
0.165" Hole
or M4 Tapped
D
2. Drawings are not to scale.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
F-31
Sockets
Dimensions
Dimensions, continued
Collective Panel Mounting
SH and SY series panel mount sockets are designed to mount collectively in panel cut-outs. Insert socket with mounting springs facing the
top and bottom edge of the panel cut-out. Push the socket until the
mounting spring clips onto the panel. (See Figure 1.)
SY4S-51
Dimension Table
Part No.
Width
Figure 1
RH2B
RY2KS
RH1B
RM2S
Relay
SY4S-51
1.063"
RY4S, RY42, RY2KS, RM2S
SH4B-51
1.772"
RH4B
SH3B-51
1.418"
RH3B, RH2LB
SH2B-51
1.063"
RH2B
SH1B-51
0.709"
RH1B
SY2S-51
0.709"
RY2S, RY22S
How to Calculate Cutout Length (L)
Cutout L = A (Total Overall Width of Each Socket) – 0.221" (+ 0", – 0.020")
F
Sockets
Example:
A = Total Overall Width of Each Socket
Cutout L = A – 0.221" (+ 0", – 0.020")
SY2S-51
SY4S-51
SY4S-51
SY4S-51
SY2S-51
SY4S-51
SH1B-51
SH1B-51
SH2B-51
L = [0.709" + 1.063" + 1.063" + 0.709" + 1.063" + 0.709" + 1.063" + 1.063"] – 0.221" = 7.93"
L = 7.93" (+ 0", – 0.020")
Mounting Plate
F-32
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Related documents
Download