Motors | Automation | Energy | Transmission & Distribution | Coatings Automation MDW Miniature Circuit Breakers DWP Residential Molded Case Circuit Breakers RDW Residual Current Circuit Breakers SPW Surge Suppressors www.weg.net Contents MDW Miniature Circuit Breakers.............................................................................................. 3 DWP Molded Case Circuit Breakers........................................................................................ 3 RDW Residual Current Circuit Breakers................................................................................... 4 SIW Switch-disconnectors....................................................................................................... 5 SPW Surge Suppressors......................................................................................................... 5 Dimensions............................................................................................................................. 11 2 MDW / DWP / RDW / SPW www.weg.net MDW Miniature Circuit Breakers seconds B Curve The main characteristic of the B curve is the instantaneous trigger for currents between 3 to 5 times the rated current. Therefore, they are mainly applied for the protection of circuits with resistive characteristics or involving significant cable distances. For example: Incandescent lamps, showers, electric heaters and so forth. Trigger Time Trigger curves The MDW miniature circuit breakers meet the B and C trigger curve characteristics in accordance with the IEC 60898 Standard, enabling their use in the most varied applications. Minutes The MDW thermomagnetic circuit breaker was developed for the protection of electrical installation against overload and short circuit. With currents that vary from 2 to 100 A, the MDW is avaliable with 1, 2, 3 or 4 poles. Thermal and magnetic triggers for protection against overload and short circuit act quiclky in detecting and extinguishing the failure. It is equipped with a “trip free” mechanism guaranteeing miniature circuit breaker performance even with the activation lever locked in the “on” position. Special contacts ensure safety against welding in case of short circuit as well as the arc extinction chamber, which absorbs the electric arc energy, extinguishing it when a short circuit occurs. The MDW miniature circuit breakers also have auxiliary contact blocks (1 NOC), supplied as accessories. C Curve The main characteristic of the C curve is the instantaneous trigger for currents between 5 to 10 times the rated current. Thus, they are mainly applied for the protection of circuits with inductive load installation. For example: Fluorescent lamps, refrigerators, washing machines and so forth. DWP Residential Molded Case Circuit Breakers Available in 175, 200 and 225 A, 3 pole version only, the DWP series circuit breakers have been developed for the protection of electrical installations against overload and short circuit. These protections are ensured by its thermal and magnetic triggers. Terminal boxes can be supplied as accessories for the DWP225 model, enabling direct cable connection up to 120 mm2. g MDW / DWP / RDW / SPW 3 www.weg.net RDW Residual Current Circuit Breakers Residential current circuit breakers are devices used for the protection of people and installations as to direct or indirect contacts. They protect against the effects of ground leakage, by detecting these leakages that can occur in electrical installation and opening the circuit. Regardless of the ground scheme, the use of these devices with sensitivity equal to or less than 30 mA is recommended in circuits: a) situated in locations containing bath or shower. b) current sockets located in areas outside the building. c) current sockets that could have to supply outside equipment. d) kitchens, dining areas, laundries, service areas, garages and inside areas subjected to water or washing through normal use. 30 mA or 300 mA sensitivity The sensitivity or rated residual operating current (ID n) is the first factor to dictate if this product can be applied for protection against indirect contacts and for complementary protection against direct contacts, or if it can only be appplied against indirect contacts. The version with 30 mA sensitivity is considered to be of high sensitivity and can be used both for protection against indirect contacts as well as for complementary protection against direct contacts, guaranteeing full user/person protection. The version with 300 mA sensitivity is considered to be of low sensitivity and can be used only for the protection of installations against indirect contacts or against fire risk (according to installation standards), limiting the fault/ground leakage currents to locations that process or store inflammable materials, such as paper, straw, wood fragments, plastics, and so forth. Operating Curve Operating Principle The residual current circuit breaker continuously measures the vectorial sum of the currents that go through circuit conductors. If the electrical circuit is running smoothly, the vetorial sum of the currents in its conductors is practically null. Should an insulation failure occur in a piece of equipment supplied by this circuit, a ground fault current will appear. When this occurs, the vectorial sum of the currents in the conductors monitored is no longer null and the device detects this current difference, opening the circuit. In the same way, if somebody touches a live part of the protected circuit, the current will circulate through the person’s body, equally causing an unbalance in the vectorial sum of the currents. This unbalance will also be detected as if it was a ground fault current. Connection diagrams 4 MDW / DWP / RDW / SPW t (ms) 10000 5000 2000 1000 500 2 1 3 4 200 100 I∆n = 30 mA 50 20 10 0.1 0,2 0,5 1 2 5 10 20 50 100 200 500 1000 2000 5000 I (mA) Zone 1 No perceivable effect. g Zone 2 Physicological effects generally not damaging. g Zone 3 Notable physicological effects (cardiac arrest, respiratory arrest, muscular contractions, generally reversable). g Zone 4 Higher probability of serious physicological effects and irreversible cardiac arrest and respiratory arrest. Residual current breaker with 30 mA sensitivity operating range. g Notes: (1) The 2 pole version are normally used in phase/neutral or phase/phase systems. (2) The 4 pole version can be used in any type of network. (3) All phase conductors, including neutral, can be connected to RDW, however, the ground conductor must not be connected. The neutral conductor in the RDW outlet must remain insulated throughout the installation and must not be connected to the ground. (4) If a 4 pole RDW is used as a 2 pole, the phase must pass through terminals 5-6 and the neutral through 7-8. www.weg.net SIW Switch-disconnectors The SIW switch-disconnectors have the same housing as the miniature circuit breakers for the 2, 3 and 4 pole versions. However, they are not provided with thermal and magnetic triggers, i.e. they do not have trigger curves. Its function is only to disconnect electrical circuits with currents of up to 100 A in accordance with IEC 60947-3 standard. SPW Surge Suppressors The surge suppressors (SPD) from the SPW series were developed to protect equipment and installations against surges and over voltages coming from direct or indirect discharges in the electrical supply, more commonly caused by lightning and/or operations in the electrical system. Regardless of the type or origin, the discharges generate a sudden increase in supply voltage – momentaneous surges and over voltages – which damage electro-electronic equipment and the installation itself. Protection Class The Class I SPD are indicated for locations subject to high intensity discharges, a typical characteristic of installations and buildings directly supplied by overhead wires exposed to atmospheric discharges. Installation of a Class I SPD is recommended at the inlet point of a building’s electrical supply. At locations where the electrical supply is not exposed to direct atmospheric discharges, typical of internal residential and/or building installations supplied by a built-in electrical supply, Class II SPD are indicated. Its installation is recommended in the distribution board. Features The SPW series are equipped with a status signaler, located on the front of the device. Although the SPDs operate many times, replacement of the module is only necessary when the signaler is red. The SPW series are Plug-in type. This concept enables the user to replace the protection module without having to disconnect the cables, as the base remains installed. MDW / DWP / RDW / SPW 5 www.weg.net Selection guide / Technical Data MDW Miniature Circuit Breakers Rated current In (A) References 1 Pole 2 Pole Curve B Curve C Curve B 3 Pole Curve C 4 Pole Curve B Curve C 2 MDW-C2 MDW-C2-2 MDW-C2-3 4 MDW-C4 MDW-C4-2 MDW-C4-3 Curve C 6 MDW-B6 MDW-C6 MDW-B6-2 MDW-C6-2 MDW-B6-3 MDW-C6-3 MDW-C6-4 10 MDW-B10 MDW-C10 MDW-B10-2 MDW-C10-2 MDW-B10-3 MDW-C10-3 MDW-C10-4 16 MDW-B16 MDW-C16 MDW-B16-2 MDW-C16-2 MDW-B16-3 MDW-C16-3 MDW-C16-4 20 MDW-B20 MDW-C20 MDW-B20-2 MDW-C20-2 MDW-B20-3 MDW-C20-3 MDW-C20-4 MDW-C25-4 25 MDW-B25 MDW-C25 MDW-B25-2 MDW-C25-2 MDW-B25-3 MDW-C25-3 32 MDW-B32 MDW-C32 MDW-B32-2 MDW-C32-2 MDW-B32-3 MDW-C32-3 MDW-C32-4 40 MDW-B40 MDW-C40 MDW-B40-2 MDW-C40-2 MDW-B40-3 MDW-C40-3 MDW-C40-4 50 MDW-B50 MDW-C50 MDW-B50-2 MDW-C50-2 MDW-B50-3 MDW-C50-3 MDW-C50-4 63 MDW-B63 MDW-C63 MDW-B63-2 MDW-C63-2 MDW-B63-3 MDW-C63-3 MDW-C63-4 70 MDW-B70 MDW-C70 MDW-B70-2 MDW-C70-2 MDW-B70-3 MDW-C70-3 MDW-C70-4 80 MDW-B80 MDW-C80 MDW-B80-2 MDW-C80-2 MDW-B80-3 MDW-C80-3 MDW-C80-4 100 MDW-B100 MDW-C100 MDW-B100-2 MDW-C100-2 MDW-B100-3 MDW-C100-3 MDW-C100-4 Technical Data Standards IEC 60898, IEC 60947-2 Rated operating voltage Ue 400 Vac Rated insulation voltage Ui 660 Vac Frequency 50 / 60 Hz Rated currents In 2 to 100A Short circuit breaking capacity - Ics / Icn NM 60898 3 kA (6 to 100A); 1.5 kA (2A. 4A) IEC 60947-2 5 kA (6 to 100A); 1.5 kA (2A, 4A) B (3 to 5 times In) Trigger curves C (5 to 10 times In) Number of poles 1, 2, 3 and 4P Ambient temperature -5 to 40 ºC Electrical life 6000 operations Mechanical life 20000 operations Degree of protection IP 20 Connection capacity MDW (2 to 63A) 1 to 25 mm² MDW (80A, 100A) 10 to 35 mm² Mounting position Without restriction Assembly DIN rail 35 mm Weight (kg) 1 pole 0.105 (2 to 63A); 0.155 (70 to 100A) 2 pole 0.210 (2 to 63A); 0.315 (70 to 100A) 3 pole 0.315 (2 to 63A); 0.475 (70 to 100A) 4 pole 0.420 (2 to 63A); 0.630 (70 to 100A) Accessories Type Contact configuration Auxiliary contact block 1 REV Application References MDW (2 to 63A) MDW-BC1 MDW (70 to 100A) MDW-BC2 Technical Data - Auxiliary contact block Contact switching capacity Weight (kg) 6 AC-14 6A (230Vac), 3A (400Vac) DC-12 2A (60Vdc), 1A (125Vdc) DC-13 6A (24Vdc), 2A (48Vdc) 0,04 MDW / DWP / RDW / SPW www.weg.net Selection Guide / Technical Data DWP Residential Molded Case Circuit Breakers Rated Current In (A) 175 200 225 Triggers Reference Fixed thermal and magnetic DWP225-200-3 DWP225-175-3 DWP225-225-3 Technical data Standard IEC 60947-2 Rated operating voltage Ue 690 Vac Insulation rated voltage Ui 800 Vac Impulse voltage Uimp 8 kV Frequency 50 / 60 Hz Rated ultimate short-curcuit breaking capacity - Icu 220/240V 22 kA 380/415V 12 kA 440V 6 kA 500V 5 kA 690V 3 kA Rated service short-curcuit breaking capacity - Ics 100% Icu Magnetic trigger 10x In Use category A Ambient temperature -5 to 40 ºC DWP225 2.09 Tripping Time (s) Weight (kg) x In MDW / DWP / RDW / SPW 7 www.weg.net Selection guide / Technical Data RDW Residual Current Circuit Breakers Residual Rated Current (mA) 30 300 References Rated Current In (A) 2 Pole 4 Pole 25 RDW30-25-2 RDW30-25-4 40 RDW30-40-2 RDW30-40-4 63 RDW30-63-2 RDW30-63-4 80 RDW30-80-2 RDW30-80-4 100 RDW30-100-2 RDW30-100-4 25 RDW300-25-2 RDW300-25-4 40 RDW300-40-2 RDW300-40-4 63 RDW300-63-2 RDW300-63-4 80 RDW300-80-2 RDW300-80-4 100 RDW300-100-2 RDW300-100-4 Technical Data Standard IEC 61008 Rated operating voltage Ue 2 pole 230 Vac 4 pole 230/400 Vac Rated insulation voltage Ui 500 Vac Frequency 50 / 60 Hz Residual rated currents IΔn 30 or 300 mA Rated currents In 25 to 100A Number of poles 2 and 4P Type AC Resistance to short circuit 6 kA Ambient temperature -25 to 40 ºC Electrical life 6000 operations Mechanical life 10000 operations Degree of protection IP 20 Connection capacity 1 to 35 mm² Mounting position Without restriction Assembly DIN rail 35 mm Weight (kg) 8 MDW / DWP / RDW / SPW 2 pole 0.255 4 pole 0.455 www.weg.net Selection Guide / Technical Data SIW Switch-disconnectors References Rated Current In (A) 2 Pole 3 Pole 4 Pole 40 SIW-40-2 SIW-40-3 SIW-40-4 63 SIW-63-2 SIW-63-3 SIW-63-4 80 SIW-80-2 SIW-80-3 SIW-80-4 100 SIW-100-2 SIW-100-3 SIW-100-4 Technical data Standard IEC 60947-3 Rated operating voltage Ue 400 Vac Rated insulation voltage Ui 660 Vac Frenquency 50 / 60 Hz Rated currents In 40 to 100A Number of poles 2, 3 and 4P Ambient temperature -5 to 40 ºC Electrical life 6000 operations Mechanical life 20000 operations Degree of protection IP 20 Connection capacity SIW (40 to 63A) 1 to 25 mm² SIW (80A, 100A) 10 to 35 mm² Mounting position Without restriction Assembly DIN rail 35 mm Weight (kg) 2 pole 0.165 (40 to 63A); 0.285 (80A, 100A) 3 pole 0.248 (40 to 63A); 0.428 (80A, 100A) 4 pole 0.330 (40 to 63A); 0.570 (80A, 100A) Accessories Type Contact configuration Application References Auxiliary contact block 1 REV SIW (40A, 63A) MDW - BC1 SIW (80A, 100A) MDW - BC2 Technical Data - Auxiliary contact block Contact switching capacity Weight (Kg) AC-14 6A/230Vac - 3A/400Vac DC-12 2A/60Vdc - 1A/125Vdc DC-13 6A/24Vdc - 2A/48Vdc 0.04 MDW / DWP / RDW / SPW 9 www.weg.net Selection Guide / Technical Data SPW Surge Suppressors (SPD) Protection Class Discharge Max. Current, 8/20µs wave Imáx (kA) Discharge Rated Current, 8/20µs wave In (kA) Impulse Max. Current Iimp (kA) II 12 5 - SPW275-12 II 20 10 - SPW275-20 II 45 20 - SPW275-45 II / I 60 30 12.5 SPW275-60/12.5 Technical Data Standard IEC 61643 Continuous operating maximum voltage Uc 275 Vca Level of protection Up SPW275-12 1.0 kV SPW275-20 1.2 kV SPW275-45 1.5 kV SPW275-60/12,5 1.5 kV Frequency 50 / 60 Hz Discharge maximum voltage Imáx According to table above Discharge rated voltage In According to table above Impulse maximum current Iimp According to table above Protection class According to table above Number of poles 1 Ambient temperature -5 to 40 ºC Degree of protection IP 20 Connection capacity 1 to 25 mm² Mounting position Without restriction Assembly DIN rail 35 mm Weight (kg) SPW275-12 0.105 SPW275-20 0.11 SPW275-45 0.115 SPW275-60/12.5 0.12 Accessories Type Protection Module Application References SPW 275-12 SPW - M275-12 SPW 275-20 SPW - M275-20 SPW 275-45 SPW - M275-45 SPW 275-60/12.5 SPW - M275-60/12.5 SPW Connection Scheme 10 References MDW / DWP / RDW / SPW www.weg.net Dimensions (mm) MDW (2A...63A) SIW (40A, 63A) Series 17,7 53,1 35,4 70,8 MDW (70A...100A) Series MDW-BC/BC2 RDW (2P, 4P) Series SPW Series DWP (175A...225A) Series MDW-BC Connection Scheme 11 12 14 MDW / DWP / RDW / SPW 11 ВЕКТОР ТЕХНОЛОГИЙ / VECTOR OF TECHNOLOGIES ул. Шафарнянская д. 18 этаж.3 этаж п.18, 220125/ Shafarnianskaya St 18, floor 3, 220125 г. Минск, Республика Беларусь/ Minsk, Republic of Belarus Тел/факс: +375-17-265-60-16/ Fax: +37517-265-60-16 Тел: +375-17-265-60-15/ Tel: +375-17-265-60-15 Website: www.vec-tech.by