AC EDGE Specifications Model AC120V60DF 6/6 P/N 1101-1188 ©2016 Transtector. All rights reserved. 1 Table of Contents Introduction ................................................................................................................................................... 3 Features and Benefits ................................................................................................................................... 3 Grounding...................................................................................................................................................... 3 Specifications ................................................................................................................................................ 4 Dimensions ................................................................................................................................................... 5 Kit Contents ................................................................................................................................................... 6 Electrical Features ........................................................................................................................................ 6 Mechanical Features ..................................................................................................................................... 7 ©2016 Transtector. All rights reserved. 2 Introduction The AC Edge 120 is a 2RU rack mount AC distribution solution to overcome discrete electrical conduit and panel challenges. Designed for mission critical electronic storage and backup systems, the AC power distribution panel is scalable for up to twelve dedicated circuits (1 A to 15 A) using 120 Vac per phase (60 A maximum) distribution. Features and Benefits Designed for demanding usage, the AC Edge offers best in class current handling and surge performance in a 2RU rack mount environment. High power, 60 A per phase panel supports demanding loads. Independent Neutral connections allow for a truly redundant power distribution unit. Robust metal chassis with passive venting keeps temperature rise to a minimum . Replaceable silicon avalanche suppression diode (SASD) surge protection modules on each phase keep loads protected from damaging transient over-voltage conditions. Wide spacing between outlet connections (L2 only) accommodates oversized pluggable transformers. IEC 320-C14 test terminals allow for a quick, low-power connection to reduce overall system test setup time. Grounding Unit shall be properly grounded per the installation instructions. Failure to do so will result in voided warranty and possible equipment damage. ©2016 Transtector. All rights reserved. 3 Specifications AC EDGE 120 Part Number 1101-1188 Electrical Feeds Maximum Continuous Operating Voltage Input Rating Output Positions Maximum Output Protection Device Maximum Neutral Current Rating Surge Protection Voltage Protection Level (500A/6kV) Duty Cycle Test Operating Voltage Input Terminals Output Terminals Test Terminals Status Indication LEDs (each line) Remote Status Indication Alarm Terminals 2, 120 Vac (Independent Neutrals) 138 Vac (per phase) 60 A Max per phase (14.4 kVA total) 6 per phase (12 total, A+B) Removable 1 A to 15 A, UL489 Listed Circuit Breakers 60 A per phase 3kA/6kV 8/20 µs per phase <450 V IEEE C62.41, 6kV/200A, 100 kHz ringwave 110-130 Vac 50/60 Hz Cage-clamp connection, supports #20 to #2 AWG feeds 12X NEMA 5-15R Outlets 2X IEC 320-C14 Inlets PWR (GRN = power on), FA (RED = tripped breaker), SURGE (GRN = normal, RED = replace) Power, Fuse, and Surge Alarm for each line, Dry Form C Contact (1 A, 138 Vac/Vdc max rated) Single 15-socket, high density, D-type connector Mechanical Mounting Material Finish Weight Dimensions (HxWxD) 19” or 23” rack in 2RU with adjustable ears Cold-rolled steel – 18 gauge Black powder coated front panel and zinc plated chassis 17lbs (approx.) 3.47” x 19.00” x 13.48” (88mm x 483mm x 342mm) Environmental Operating Temperature Flammability 14ºF to 131ºF (-10ºC to +55ºC) UL94 V-0 Installation Mounting Installation Hardware Grounding 19” or 23” rack in 2RU with adjustable ears Provided 2X, 1/4-20 studs on 5/8” centers Regulatory Compliance UL Certification UL/cUL Listed, E211453 Warranty Warranty 1 year ©2016 Transtector. All rights reserved. 4 Dimensions ©2016 Transtector. All rights reserved. 5 Kit Contents Part Number Rack Mount Hardware Designation Card Quick Installation Guide Installation Manual AC EDGE 120 1101-1188 Yes (19” brackets) Yes Yes PDF download only (visit www.transtector.com) Electrical Features AC Edge features independent neutrals for each phase allowing for fully redundant system integration. At the power source(s), install one, single pole, high inrush circuit breakers per phase (75 A max each, derated 80%), or a 2-pole breaker with identified handle tie following proper wire sizing and conduit guidelines (per NFPA 70 2011 Article 220, Chapter 9 and local/national codes). Refer to installation manual found on www.transtector.com for more detailed information. ©2016 Transtector. All rights reserved. 6 Mechanical Features Widely spaced outlets yield ample room for oversized power transformers (“wall-warts”) to be placed side by side. ©2016 Transtector. All rights reserved. 7 Transtector Systems, Inc. 10701 Airport Drive, Hayden ID 83835 (TF) 800.882.9110 | (FX) 208.762.6034 DRAWN DATE TREVOR TOLLEFSOL 01/29/2015 CHECKED DATE DPM 1/28/2016 ENGRG APPD DATE MPD 2/2/2016 PROJ APPD DATE DWR 2/2/2016 APPROVED DATE DLR 2/2/2016 Notice: The information and design in this document is the property of Transtector Systems. All rights reserved. 1101-1188-C REV C ©2016 Transtector. All rights reserved. 8