MARSA Surge Protector catalogue product catalo gue SAFEGUARD YOUR ELECTRONICS FROM TRANSIENT SURGE POWER SURGE PROTECTOR [ PSP1 20415 , PSP1 40415 , PSP1 80415 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION These products are located in category B and C power surge protector. Protection designed for three phase electrical supply system. Applied parallel to incoming feeder for power supply distribution board. These devices are ready to divert lightning surge current generated in electrical power line safely to earth. Protection at this location is effective in suppressing the much frequent lightning generated surge internal generated and over-charging transient conditions. SCHEMATIC DIAGRAM FEATURES AND BENEFITS Full mode protection. All mode protection covers all Line-Neutral (L-N), Line-Earth (L-E), and Neutral-Earth (N-E) Each mode is protected by the single MOV with the same current rating. Ensure reliability of surge protectors to the facilities and equipments. Maximum surge current greatly in excess of the 20kA for PSP1 20415, 40 kA for PSP1 40415 and 80kA for PSP1 80415. Double protection unit suitable to Malaysia extreme lightning strength and frequency. Designed for three phase power line suitable for bungalows, shops, offices and small factories CONNECTION ELECTRICAL SPECIFICATIONS SPECIFICATION Description/type Current surge rating per phase Total current protection rating Nominal voltage (RMS) Working voltage (RMS) Frequency range Current rating (supply) PSP1-40415 PSP1-80415 Parallel Surge Diverter 20 kA 40kA 80kA 140kA 280kA 560kA 415V 373V-457V 40Hz – 60Hz Direct connection to power source up to 60A. Connection via series MCCB or switch fuse to supplies greater than 60A MOV leakage current Indicator circuit current Volt free contact Temperature range Connection type PSP1-20415 <300µA <500µA <5mA Screw Terminal -40 to +85°C Screw Terminal <600µA LET TROUGH VOLTAGE SPECIFICATION Compliance standard 20kV 1.2/50µs open circuit voltage 10kA 8/20µs short circuit current 10kV 1.2/50µs open circuit voltage 5kA 8/20µs short circuit current 6kV 1.2/50µs open circuit voltage 3kA 8/20µs short circuit current PSP1-20415 <1.7kV PSP1-40415 MS IEC 61643-1:2004 IEEE C62.41-1991 BS 6651-1999 PSP1-80415 <1.7kV <1.8kV <1.2kV <750V <750V <950V PSP1-20415 PSP1-80415 1.1kg PSP1-40415 6mm² 16mm² Screw Terminal 1.2kg 157mm (L) x 159mm (W) x 74mm (H) 157mm (L) x 159mm (W) x 74mm (H) 192mm (L) x 169mm (W) x 97mm (H) MECHANICAL SPECIFICATIONS SPECIFICATION Min. Conductor Size Max. Conductor Size Earth Connection Weight per unit Dimensions PSP1 20415 PSP1 40415 1.3kg PSP1 80415 POWER SURGE PROTECTOR [ PSP1 20240 , PSP1 40240 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION These products are located in category B and C power surge protector. Protection designed for single phase electrical supply system. Applied parallel to incoming feeder for power supply distribution board. These devices are ready to divert lightning surge current generated in electrical power line safely to earth. Protection at this location is effective in suppressing the much frequent lightning generated surge internal generated and over-charging transient conditions. SCHEMATIC DIAGRAM FEATURES AND BENEFITS Full mode protection. All mode protection covers all Line-Neutral (L-N), Line-Earth (L-E), and Neutral-Earth (N-E) Each mode is protected by the single MOV with the same current rating. Ensure reliability of surge protectors to the facilities and equipments. Maximum surge current greatly in excess of the 20kA for PSP1 20240 AND 40 kA for PSP1 40240. Double protection unit suitable to Malaysian extreme lightning strength and frequency. Designed for single phase power line suitable for bungalows, shops, offices and small factories CONNECTION ELECTRICAL SPECIFICATIONS SPECIFICATION Description/type Current surge rating per phase Total current protection rating Nominal voltage (RMS) Working voltage (RMS) Frequency range Current rating (supply) PSP1-20240 PSP1-40240 Parallel Surge Diverter 20 kA 40kA 60kA 120kA 240V 215V-275V 40Hz-60Hz Direct connection to power source up to 60A. Connection via series MCCB or switch fuse to supplies greater than 60A MOV leakage current Indicator circuit current Volt free contact Temperature range Connection type <300µA <500µA <5mA Screw Terminal -40 to +85°C Screw Terminal LET TROUGH VOLTAGE SPECIFICATION Compliance standard 20kV 1.2/50µs open circuit voltage 10kA 8/20µs short circuit current 10kV 1.2/50µs open circuit voltage 5kA 8/20µs short circuit current 6kV 1.2/50µs open circuit voltage 3kA 8/20µs short circuit current PSP1-20240 PSP1-40240 MS IEC 61643-1:2004 IEEE C62.41-1991 BS 6651-1999 <2kV <1.2kV <650V <750V PSP1-20240 PSP1-40240 MECHANICAL SPECIFICATIONS SPECIFICATION Min. Conductor Size Max. Conductor Size Earth Connection Weight per unit Dimensions PSP1-20240 6mm² 16mm² Screw Terminal 0.7kg 0.8kg 57mm (L) x 148mm (W) x 70mm (H) PSP1-40240 PLUG IN CAT A PROTECTOR [ PISP1-01 , PISP1-03 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION MARSA plug in housed in safe, designed for all as the last equipment. In overvoltage, it explode. cat A surge protector are all metal enclosure. It is plug in equipment acting barrier for electronic the event of prolonged will not catch fire or FEATURES AND BENEFITS All mode protection Ensure maximum level of protection achieved at all time. Designed for installation in any wiring system worldwide. PISP1-01 DIMENSION PISP1-03 ELECTRICAL SPECIFICATIONS SPECIFICATION PISP1-01 PISP1-03 Description/type Plug Switch Protection mode Full Mode (L-N, L-E, N-E) Connection Type Series Protection Stage MOV, LC Filters Nominal voltage ( RMS ) 220 / 230 / 240V AC RMS Working voltage (RMS) 200V - 280V AC RMS Max. Load Current 10A – 15A Max. Load Drop < 2.2V at full load Working Frequency 40Hz – 60Hz Temperature range -40 to +85°C Working Humidity 0 – 90% Peak surge handling per mode (8/20µs) 30kA Let Through Voltage <300V Response Time Standard compliance <4ns IEEE C62.41-1991 Cat A, B, C; BS 66511999 Cat A, B, C; IEC 61000-4-5; IEC 61643-1-2; UL 1449 Second Edition <250µA Earth Leakage Weight per unit Dimensions 1.1kg 140mm (L) x 82mm (W) x 34.5mm (H) 1.6kg 294mm (L) x 82mm (W) x 34.5mm (H) POWER SERIES PROTECTOR [ PLP1-240 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION Efficient solution for in-line protection from transient surge. It works by limiting the impulse voltage from several thousand volts to its clamping voltage . APPLICATION Suitable for installation for low current operated equipment up to 5A. Design to suit the needs for direct installation from power supply such as CCTV, fire alarm panel and telemetry system. FEATURES AND BENEFITS Provides a range of transient and operating performance characteristic to protect AC power line connected directly to equipment. Appropriate as the transient protection for SCADA and telemetry system, interfacing system as well as alarm monitoring system. Easy installation with DIN rail foot to be incorporated to the system. Light indicator provided to indicate functionality of protection. DIMENSION ELECTRICAL SPECIFICATIONS SPECIFICATION PLP1-240 Description/type Low Current Surge Protector Protection mode Full Mode (L-N,L-E,N-E) Connection Type Series Protection Stage All MOV Nominal voltage ( RMS ) 220 / 230 / 240V AC RMS Working voltage ( RMS ) 200V - 280V AC RMS Max. Load Current Max. Load Drop 1A – 5A < 0.2V at full load Temperature range -40 to +85°C Working Humidity 0 – 90% Working Frequency 40Hz – 60Hz Peak surge handling per mode (8/20µs) 15kA Let Through Voltage <500V Standard compliance IEEE C62.41-1991 Cat A, B, C; BS 66511999 Cat A, B, C; IEC 61000-4-5; IEC 61643-1-2; UL 1449 Second Edition Response Time <2ns Weight 450g Earth Leakage <25µA VIDEO LINE PROTECTOR [ CXP1-103 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION This coaxial cable surge protector (CXP103) works in frequency range up to 100MHz at 3dB. It works by limiting the impulse voltage from several thousand volts to its clamping voltage of about 300V. APPLICATION DIMENSION Used to protect CATV consumer’s installation. Suitable for use on frequency range up to 100MHz at 3dB FEATURES AND BENEFITS Simple plug-in installation. High impulse rating. Robust design. Wide operating frequency range up to 100MHz at 3dB. Adjustable coaxial cable connectors are available upon request. Low let trough voltage up to 300V with 4kV, 100/700us, 35Ohm. Test pulse as ITU-T K17 & K20, (4kV, 10/700us, 25Ohm). ELECTRICAL SPECIFICATIONS SPECIFICATION CXP1-103 Description/type LAN, Coaxial Video Cable Protection mode Common Mode Connection Type Series Protection Stage Multistage Max Working voltage (RMS) 12V Temperature range -40 to +85°C Working Humidity 0 – 90% Peak surge handling per mode (8/20µs) 10kA Let Through Voltage 17V Standard compliance ITUT ( CCIT ) IX K17, K20, K21, K44, BS6651 Cat AB, AS1768-2003, Cat A,B,C IEC61643-21, IEC Telecommunication Insertion Loss (for coaxial and CCTV) Cable Impedance (for coaxial and CCTV) < 1dB at 20MHz Suitable for 50Ω and 75Ω system In Line Resistance 1Ω per line Working frequency 10MHz 3dB Weight Dimensions 100g 24.8mm (L) x 39.2mm (W) x 26.8mm(H) KRONE PROTECTOR [ DKP1-1, DKP1-10 ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION Subscriber distribution frame is the main source of entrance into telecommunication remote access network cabinet. This is the place where the primary surge protection devices is installed to protect the subscriber line interface circuit (SLIC) APPLICATION High density MDF protection for KRONE system. Include PSTN, RS232, UTE and E1/T1. FEATURES AND BENEFITS Surge rating of 20kA. Multistage protection. Easy installation. Maintenance free. Protection for single pair circuits. Unique line side PCB tracks fuse indicates line failure. ACA approved and ABS flame retardant enclosure. DIMENSION ELECTRICAL SPECIFICATIONS SPECIFICATION DKP-01 DKP-10 Description/type Multistage Surge Protector (KRONE) Protection mode Common Mode Connection Type Series Max Working voltage (RMS) L-L L-N N-E 200V 200V 200V Working frequency 40Hz – 60Hz Temperature range -40°C to +85°C Working Humidity 0 – 90% Peak surge handling per mode (8/20µs) 10kA Let Through Voltage <140V Standard compliance ITUT ( CCIT ) IX K17, K20, K21, K44, BS6651 Cat AB, AS1768-2003, Cat A,B,C IEC61643-21, IEC Telecommunication In Line Resistance Weight 8Ω per line 6g 160g (set with magazine) SIGNAL & DATA LINE PROTECTOR [ DLP1-12, DLP1-24, DLP1-30, DLP1-PSTN ] “PROTECTS YOUR HOME, BUSINESS AND INDUSTRIAL FROM LIGHTNING SURGE” DESCRIPTION It works by limiting the impulse voltage from several thousand volts to its clamping voltage of several dozens of volts depending on device rating. APPLICATION Suitable for all signal lines with operating current up to 350mA. FEATURES AND BENEFITS Provides a range of transient and operating performance characteristic to protect telecommunication terminal and interface equipment from transient on the telecommunication lines. Appropriate as the transient protection for SCADA and telemetry system, interfacing system as well as alarm monitoring system. Provides efficient surge clamping voltage with minimal attenuation at the high bit currently in use. DIMENSION ELECTRICAL SPECIFICATIONS SPECIFICATION DLP1-12 DLP1-24 DLP1-30 Description/type Multistage Data Line Protector Protection mode Common / Differential Connection Type Series Protection Stage Multistage Protection Working Voltage Normal Maximum 12V 14V 24V 26V 30V 35V Temperature range -40 to +85°C Working Humidity 0 – 90% Working Frequency 20MHz/HF Peak surge handling per mode (8/20µs) Standard compliance 10kA 42V 45V 76V ITUT ( CCIT ) IX K17, K20, K21, K44, BS6651 Cat A-B, AS1768-2003, Cat A,B,C IEC61643-21, IEC Telecommunication In Line Resistance 10Ω Weight 250g Conductor Size Dimension PSTN PSTN 350mA Maximum working current Let Through Voltage DLP1-PSTN 2.5mm² 110mm (L) x 19.6mm (W) x 29.4mm (H) 125V SOLE DISTRIBUTOR VLP ENGINNERING SDN BHD 25-1-1 Jln Medan Putra 3 (3/62D) Bandar Menjalara, Kepong 52200 Kuala Lumpur, Malaysia. Tel : +603-62763264 Fax: +603-62774697 E-mail : VLPEngineering@yahoo.com AUTHORIZED AGENT