MARSA Surge Protector Surge Protector Surge Protector

advertisement
MARSA Surge Protector
catalogue
product catalo
gue
SAFEGUARD YOUR ELECTRONICS
FROM TRANSIENT SURGE
POWER SURGE PROTECTOR
[ PSP1 20415 , PSP1 40415 , PSP1 80415 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
These products are located in category B
and C power surge protector. Protection
designed for three phase electrical supply
system. Applied parallel to incoming
feeder for power supply distribution
board.
These devices are ready to divert
lightning surge current generated in
electrical power line safely to earth.
Protection at this location is effective in
suppressing the much frequent lightning
generated surge internal generated and
over-charging transient conditions.
SCHEMATIC DIAGRAM
FEATURES AND BENEFITS
Full mode protection. All mode protection
covers all Line-Neutral (L-N), Line-Earth
(L-E), and Neutral-Earth (N-E)
Each mode is protected by the single MOV
with the same current rating.
Ensure reliability of surge protectors to
the facilities and equipments.
Maximum surge current greatly in excess
of the 20kA for PSP1 20415, 40 kA for PSP1
40415 and 80kA for PSP1 80415.
Double protection unit suitable to
Malaysia extreme lightning strength and
frequency.
Designed for three phase power line
suitable for bungalows, shops, offices and
small factories
CONNECTION
ELECTRICAL SPECIFICATIONS
SPECIFICATION
Description/type
Current surge rating per phase
Total current protection rating
Nominal voltage (RMS)
Working voltage (RMS)
Frequency range
Current rating (supply)
PSP1-40415
PSP1-80415
Parallel Surge Diverter
20 kA
40kA
80kA
140kA
280kA
560kA
415V
373V-457V
40Hz – 60Hz
Direct connection to power source up to 60A.
Connection via series MCCB or switch fuse to supplies greater than 60A
MOV leakage current
Indicator circuit current
Volt free contact
Temperature range
Connection type
PSP1-20415
<300µA
<500µA
<5mA
Screw Terminal
-40 to +85°C
Screw Terminal
<600µA
LET TROUGH VOLTAGE
SPECIFICATION
Compliance standard
20kV 1.2/50µs open circuit voltage
10kA 8/20µs short circuit current
10kV 1.2/50µs open circuit voltage
5kA 8/20µs short circuit current
6kV 1.2/50µs open circuit voltage
3kA 8/20µs short circuit current
PSP1-20415
<1.7kV
PSP1-40415
MS IEC 61643-1:2004
IEEE C62.41-1991
BS 6651-1999
PSP1-80415
<1.7kV
<1.8kV
<1.2kV
<750V
<750V
<950V
PSP1-20415
PSP1-80415
1.1kg
PSP1-40415
6mm²
16mm²
Screw Terminal
1.2kg
157mm (L) x 159mm (W)
x 74mm (H)
157mm (L) x 159mm (W)
x 74mm (H)
192mm (L) x 169mm (W)
x 97mm (H)
MECHANICAL SPECIFICATIONS
SPECIFICATION
Min. Conductor Size
Max. Conductor Size
Earth Connection
Weight per unit
Dimensions
PSP1 20415
PSP1 40415
1.3kg
PSP1 80415
POWER SURGE PROTECTOR
[ PSP1 20240 , PSP1 40240 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
These products are located in category B
and C power surge protector. Protection
designed for single phase electrical supply
system. Applied parallel to incoming
feeder for power supply distribution
board.
These devices are ready to divert
lightning surge current generated in
electrical power line safely to earth.
Protection at this location is effective in
suppressing the much frequent lightning
generated surge internal generated and
over-charging transient conditions.
SCHEMATIC DIAGRAM
FEATURES AND BENEFITS
Full mode protection. All mode protection
covers all Line-Neutral (L-N), Line-Earth
(L-E), and Neutral-Earth (N-E)
Each mode is protected by the single MOV
with the same current rating.
Ensure reliability of surge protectors to
the facilities and equipments.
Maximum surge current greatly in excess
of the 20kA for PSP1 20240 AND 40 kA for
PSP1 40240.
Double protection unit suitable to
Malaysian extreme lightning strength and
frequency.
Designed for single phase power line
suitable for bungalows, shops, offices and
small factories
CONNECTION
ELECTRICAL SPECIFICATIONS
SPECIFICATION
Description/type
Current surge rating per phase
Total current protection rating
Nominal voltage (RMS)
Working voltage (RMS)
Frequency range
Current rating (supply)
PSP1-20240
PSP1-40240
Parallel Surge Diverter
20 kA
40kA
60kA
120kA
240V
215V-275V
40Hz-60Hz
Direct connection to power source up to 60A.
Connection via series MCCB or switch fuse to supplies greater than 60A
MOV leakage current
Indicator circuit current
Volt free contact
Temperature range
Connection type
<300µA
<500µA
<5mA
Screw Terminal
-40 to +85°C
Screw Terminal
LET TROUGH VOLTAGE
SPECIFICATION
Compliance standard
20kV 1.2/50µs open circuit voltage
10kA 8/20µs short circuit current
10kV 1.2/50µs open circuit voltage
5kA 8/20µs short circuit current
6kV 1.2/50µs open circuit voltage
3kA 8/20µs short circuit current
PSP1-20240
PSP1-40240
MS IEC 61643-1:2004
IEEE C62.41-1991
BS 6651-1999
<2kV
<1.2kV
<650V
<750V
PSP1-20240
PSP1-40240
MECHANICAL SPECIFICATIONS
SPECIFICATION
Min. Conductor Size
Max. Conductor Size
Earth Connection
Weight per unit
Dimensions
PSP1-20240
6mm²
16mm²
Screw Terminal
0.7kg
0.8kg
57mm (L) x 148mm (W) x 70mm (H)
PSP1-40240
PLUG IN CAT A PROTECTOR
[ PISP1-01 , PISP1-03 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
MARSA plug in
housed in safe,
designed for all
as the last
equipment. In
overvoltage, it
explode.
cat A surge protector are
all metal enclosure. It is
plug in equipment acting
barrier for electronic
the event of prolonged
will not catch fire or
FEATURES AND BENEFITS
All mode protection
Ensure maximum level of protection
achieved at all time.
Designed for installation in any wiring
system worldwide.
PISP1-01
DIMENSION
PISP1-03
ELECTRICAL SPECIFICATIONS
SPECIFICATION
PISP1-01
PISP1-03
Description/type
Plug Switch
Protection mode
Full Mode (L-N, L-E, N-E)
Connection Type
Series
Protection Stage
MOV, LC Filters
Nominal voltage ( RMS )
220 / 230 / 240V AC RMS
Working voltage (RMS)
200V - 280V AC RMS
Max. Load Current
10A – 15A
Max. Load Drop
< 2.2V at full load
Working Frequency
40Hz – 60Hz
Temperature range
-40 to +85°C
Working Humidity
0 – 90%
Peak surge handling per mode (8/20µs)
30kA
Let Through Voltage
<300V
Response Time
Standard compliance
<4ns
IEEE C62.41-1991 Cat A, B, C; BS 66511999 Cat A, B, C; IEC 61000-4-5; IEC
61643-1-2; UL 1449 Second Edition
<250µA
Earth Leakage
Weight per unit
Dimensions
1.1kg
140mm (L) x 82mm (W)
x 34.5mm (H)
1.6kg
294mm (L) x 82mm (W)
x 34.5mm (H)
POWER SERIES PROTECTOR
[ PLP1-240 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
Efficient solution for in-line protection
from transient surge. It works by limiting
the impulse voltage from several thousand
volts to its clamping voltage .
APPLICATION
Suitable for installation for low current
operated equipment up to 5A. Design to suit
the needs for direct installation from power
supply such as CCTV, fire alarm panel and
telemetry system.
FEATURES AND BENEFITS
Provides a range of transient and operating
performance characteristic to protect AC
power line connected directly to
equipment.
Appropriate as the transient protection for
SCADA and telemetry system, interfacing
system as well as alarm monitoring system.
Easy installation with DIN rail foot to be
incorporated to the system.
Light indicator provided to indicate
functionality of protection.
DIMENSION
ELECTRICAL SPECIFICATIONS
SPECIFICATION
PLP1-240
Description/type
Low Current Surge Protector
Protection mode
Full Mode (L-N,L-E,N-E)
Connection Type
Series
Protection Stage
All MOV
Nominal voltage ( RMS )
220 / 230 / 240V AC RMS
Working voltage ( RMS )
200V - 280V AC RMS
Max. Load Current
Max. Load Drop
1A – 5A
< 0.2V at full load
Temperature range
-40 to +85°C
Working Humidity
0 – 90%
Working Frequency
40Hz – 60Hz
Peak surge handling per mode
(8/20µs)
15kA
Let Through Voltage
<500V
Standard compliance
IEEE C62.41-1991 Cat A, B, C; BS 66511999 Cat A, B, C; IEC 61000-4-5; IEC
61643-1-2; UL 1449 Second Edition
Response Time
<2ns
Weight
450g
Earth Leakage
<25µA
VIDEO LINE PROTECTOR
[ CXP1-103 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
This coaxial cable surge protector
(CXP103) works in frequency range up to
100MHz at 3dB. It works by limiting the
impulse voltage from several thousand
volts to its clamping voltage of about
300V.
APPLICATION
DIMENSION
Used to protect CATV consumer’s
installation.
Suitable for use on frequency range up to
100MHz at 3dB
FEATURES AND BENEFITS
Simple plug-in installation.
High impulse rating.
Robust design.
Wide operating frequency range up to
100MHz at 3dB.
Adjustable coaxial cable connectors are
available upon request.
Low let trough voltage up to 300V with
4kV, 100/700us, 35Ohm.
Test pulse as ITU-T K17 & K20, (4kV,
10/700us, 25Ohm).
ELECTRICAL SPECIFICATIONS
SPECIFICATION
CXP1-103
Description/type
LAN, Coaxial Video Cable
Protection mode
Common Mode
Connection Type
Series
Protection Stage
Multistage
Max Working voltage (RMS)
12V
Temperature range
-40 to +85°C
Working Humidity
0 – 90%
Peak surge handling per mode (8/20µs)
10kA
Let Through Voltage
17V
Standard compliance
ITUT ( CCIT ) IX K17, K20, K21, K44, BS6651 Cat AB, AS1768-2003, Cat A,B,C IEC61643-21,
IEC Telecommunication
Insertion Loss (for coaxial and CCTV)
Cable Impedance (for coaxial and CCTV)
< 1dB at 20MHz
Suitable for 50Ω and 75Ω system
In Line Resistance
1Ω per line
Working frequency
10MHz 3dB
Weight
Dimensions
100g
24.8mm (L) x 39.2mm (W) x 26.8mm(H)
KRONE PROTECTOR
[ DKP1-1, DKP1-10 ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
Subscriber distribution frame is the main
source of entrance into telecommunication
remote access network cabinet. This is the
place where the primary surge protection
devices is installed to protect the
subscriber line interface circuit (SLIC)
APPLICATION
High density MDF protection for KRONE
system.
Include PSTN, RS232, UTE and E1/T1.
FEATURES AND BENEFITS
Surge rating of 20kA.
Multistage protection.
Easy installation.
Maintenance free.
Protection for single pair circuits.
Unique line side PCB tracks fuse indicates
line failure.
ACA approved and ABS flame retardant
enclosure.
DIMENSION
ELECTRICAL SPECIFICATIONS
SPECIFICATION
DKP-01
DKP-10
Description/type
Multistage Surge Protector (KRONE)
Protection mode
Common Mode
Connection Type
Series
Max Working voltage (RMS)
L-L
L-N
N-E
200V
200V
200V
Working frequency
40Hz – 60Hz
Temperature range
-40°C to +85°C
Working Humidity
0 – 90%
Peak surge handling per mode (8/20µs)
10kA
Let Through Voltage
<140V
Standard compliance
ITUT ( CCIT ) IX K17, K20, K21, K44, BS6651 Cat AB, AS1768-2003, Cat A,B,C IEC61643-21,
IEC Telecommunication
In Line Resistance
Weight
8Ω per line
6g
160g (set with magazine)
SIGNAL & DATA LINE PROTECTOR
[ DLP1-12, DLP1-24, DLP1-30, DLP1-PSTN ]
“PROTECTS YOUR HOME,
BUSINESS AND INDUSTRIAL
FROM LIGHTNING SURGE”
DESCRIPTION
It works by limiting the impulse voltage
from several thousand volts to its clamping
voltage of several dozens of volts depending
on device rating.
APPLICATION
Suitable for all signal lines with operating
current up to 350mA.
FEATURES AND BENEFITS
Provides a range of transient and operating
performance characteristic to protect
telecommunication terminal and interface
equipment from transient on the
telecommunication lines.
Appropriate as the transient protection for
SCADA and telemetry system, interfacing
system as well as alarm monitoring system.
Provides efficient surge clamping voltage
with minimal attenuation at the high bit
currently in use.
DIMENSION
ELECTRICAL SPECIFICATIONS
SPECIFICATION
DLP1-12
DLP1-24
DLP1-30
Description/type
Multistage Data Line Protector
Protection mode
Common / Differential
Connection Type
Series
Protection Stage
Multistage Protection
Working Voltage
Normal
Maximum
12V
14V
24V
26V
30V
35V
Temperature range
-40 to +85°C
Working Humidity
0 – 90%
Working Frequency
20MHz/HF
Peak surge handling per mode
(8/20µs)
Standard compliance
10kA
42V
45V
76V
ITUT ( CCIT ) IX K17, K20, K21, K44,
BS6651 Cat A-B, AS1768-2003,
Cat A,B,C IEC61643-21,
IEC Telecommunication
In Line Resistance
10Ω
Weight
250g
Conductor Size
Dimension
PSTN
PSTN
350mA
Maximum working current
Let Through Voltage
DLP1-PSTN
2.5mm²
110mm (L) x 19.6mm (W) x 29.4mm (H)
125V
SOLE DISTRIBUTOR
VLP ENGINNERING SDN BHD
25-1-1 Jln Medan Putra 3 (3/62D)
Bandar Menjalara, Kepong
52200 Kuala Lumpur, Malaysia.
Tel : +603-62763264 Fax: +603-62774697
E-mail : VLPEngineering@yahoo.com
AUTHORIZED AGENT
Download