EB 45 Ah European Batteries EB 45 Ah | Type: High Energy | Cell Model: 001 | Version: 1.3 ELECTRICAL CHARACTERISTICS AT 25 O C Nominal Capacity @ C/5 (Ah) 45 Average Operating Voltage @ C/5 (V) 3.2 Internal Impedance AC 1000 Hz (mΩ) <2.0 Energy Density (Wh/kg) 146 System Lithium-Iron-Phosphate LiFePO4 cathode Graphite anode RECOMMENDED OPERATING CONDITIONS Continuous Discharge (A) Pulse Discharge (A), 30 s, Voltage>2,5 V Pulse Discharge (A), 10 s, Voltage>2,5 V Charge Current (A) Maximum Charge Voltage (V) Discharge Voltage Cutoff (V) Storage Temperature (°C) Charge Temperature (°C) Discharge Temperature (°C) Min – 30 0 – 20 45 135 160 22.5 3.65 2.5 Max 45 45 45 Min – 40 – 10 – 25 135 160 210 45 135 3.65 2.5 Max 60 60 60 MAXIMUM OPERATING CONDITIONS Continuous Discharge (A) Pulse Discharge (A), 30 s, Voltage>2,5 V Pulse Discharge (A), 10 s, Voltage>2,5 V Charge Current (A) Pulse Charge (below 80% SOC, A) Maximum Charge Voltage (V) Discharge Voltage Cutoff (V) Storage Temperature (°C) Charge Temperature (°C) Discharge Temperature (°C) MECHANICAL CHARACTERISTICS Width (mm) Height (without terminal, mm) Thickness (mm) Weight (g) 165 ± 1 275 ± 1 13 ± 0.5 990 ± 10 CELL PERFORMANCE Voltage Curves at Different Discharge Rates at 23 ˚C Temperature characteristics at 0.2 C discharge. Life cycle performance at 23˚C and at 60˚C Voltage, V 3,5 Voltage, V 3,5 Capacity, % 3,3 0.2 C 0.5 C 1.0 C 2.0 C 3.0 C 3,1 2,9 2,7 60 ˚C 50 ˚C 40 ˚C 30 ˚C 20 ˚C 10 ˚C 0 ˚C -10 ˚C -20 ˚C -30 ˚C 3,3 3,1 2,9 2,7 2,5 0 % 20 % 40 % 60 % 80 % 100 % 120 % 2,5 0 % 20 % 40 % 60 % 80 % 100 % 120 % Discharge Capacity, % 105% 100% 95% 90% 85% 80% 75% 70% 65% 60% 1C/0.5C at 25°C 0.5C/0.5C at 60°C 0 500 1000 1500 2000 2500 3000 3500 4000 Discharge Capacity, % Cycle, # The information contained in this datasheet pertains specifically to the average battery cell characteristics at the time of publication. This information cannot be guarantee or warranty claims and can be derived on the product properties of cells. The actual characteristics and the lifetime of the cells are mainly influenced by the temperature, storage conditions, unloading and loading conditions of the application. It is the responsibility of the user that the application complies with all relevant operating and safety instructions to the cells in accordance with existing standards and regulations. Specifications are subject to change without notice. European Batteries Oy EB DOCUMENT ID: RD 1200063 Karapellontie 11 FI–02610 ESPOO, Finland info@europeanbatteries.com www.europeanbatteries.com