5 kVA Highly Reliable Online UPS Input / Output AC [Single-phase 2-wire] V Output capacity 5 200, 208, 220, 230, 240 A11J kVA (kW) (9.0) Battery backup time Load power factor = 0.8 Only 5 kVA type (A11J502A002TU) is UL certified and CE marking. 5 Network Support ネットワーク対応 19インチラック 対応 常時インバータ 給電 19-inch Rack Mountable ネットワーク対応 19インチラック 対応 常時インバータ 給電 Mounting examples Vertical mounting or 19-inch rack mounting. Optional rack support rails are available. The orientation of the front LCD display panel is changeable. 10 (4.5) 10 kVA min. 3U size (130 mm) Battery selection options * 15 25 35 45 min. min. min. min. 30 60 180 min. min. min. * There are some restrictions on the combination with the installation method and output capacity. 1 High Reliability The compact 3U size of the 5 kVA UPS unit allows to mount it in an EIA 19-inch rack. 2 High Power Factor Periodically performs battery self-tests, ensuring it maintains 0.9 load power factor enables the unit to supply power to high the ability to operate in outages. power factor devices such as servers. Battery tests do not cause momentary power outages. * You can select the frequency of the battery test. Start operation test Normal operation Periodic check Check battery power supply Output capacity of 5 kVA 10 kVA 4.5 kW Max. 9.0 kW Max. 3 Wide Input Voltage Range When the load factor is less than 70%, it can operate with -40% to +15% of the nominal. Return to normal operation It reduces the use of batteries. Results in longer battery life and high reliability. 4 Easy Maintenance Maintenance can be easily performed by replacing the battery or inverter from the front. Battery can be replaced even during operation. External View 5 kVA front 10 kVA back InverterON / STAND BY Switch Input LED Optional Card Interface Unit-to-Unit Interface Backup LED PC Interface Warning LED Input LED INPUT UIF A1 UIF A2 UIF A1 UIF A2 UIF B1 UIF B2 UIF B1 UIF B2 PC I/F CARD I/F OUTPUT ALARM LCD Contact Signal Interface Output LED Alarm LED MAIN MCCB Menu Operation Switch Output LED SIGNAL I/F REMOTE/EPO OPTION CARD External Control Terminal Main MCCB InverterON / STAND BY Switch EXT. BATTERY MAINTENANCE MCCB EXT. BATTERY MAINTENANCE MCCB You can change the orientation of the front LCD display panel. Cooling Fan ON ON OFF OUTPUT B MCCB OUTPUT C,D MCCB OFF OUTPUT A MCCB 5 kVA back Contact Signal Interface Cooling Fan Optional Card Interface OUTPUT C L OUTPUT D External Control Terminal INPUT N OUTPUT A E INPUT INPUT OUTPUT OUTPUT U OUTPUT NEMA L6-20R V OUTPUT B Optional Slot I/O Terminal Block Unit-to-Unit Interface PC Interface I/O Terminal Block NEMA L6-30R Network Options Item Model Remarks LAN interface card PRLANIF003-US This interface card allows UPS units to directly connect to LAN. It monitors and reports on power supply status, takes quick action in case of a power failure and other malfunction, and informs the system administrator via E-mail on any power problems. Support for SSH (Secure SHell). Provides continuous monitoring and reporting of power conditions. Power problems can also be reported to the system manager via e-mail. PRLANIF005-US (Environmental monitoring function) This model includes the functions of the PRLANIF003 and adds the capability to monitor UPS ambient temperature and humidity utilizing temperature and humidity sensors. Temperature sensor : PRLANSN001, Humidity sensor : PRLANSN002 (sold separately) PMS40J00E (Windows version without cable) PMS41J00E (Multi-OS version * without cable) This software automatically shuts down the system and stops the UPS when a failure occurs in the commercial power supply. Smooth power management is still ensured even when the UPS is connected to many computers. See our web site for the most recent list of supported operating systems. SANUPS SOFTWARE * For Windows, Unix and Linux. Optional Battery Composition ■ Battery Box Output capacity 5 kVA Output capacity 10 kVA UPS Unit P/N: A11J502A002TU Model No. UL / CE UPS Unit P/N:A11J103A002TE 15 min. 25 min. 35 min. 45 min. 15 min. 25 min. BCA11J005A00UA 1unit ― 1unit ― ― ― 35 min. ― BCA11J005A00UB ― 1unit 1unit 2 unit ― ― ― 2 unit BCA11J005A00AE ― ― ― ― ― ― 2 unit BCA11J005A00BE ― ― ― ― ― 1 unit ― ― BCA11J005A00CE ― ― ― ― ― ― ― 2 unit Capacity of battery (Ah・cell) 960 1440 1920 2400 1290 2880 3840 ■ Battery Cabinet [Not UL-certified and CE-marking] Model No. Output capacity 5 kVA Output capacity 10 kVA UPS Unit P/N: A11J502A002TU UPS Unit P/N:A11J103A002TE 30 min. 60 min. 180 min. 30 min. 60 min. BCA11J028A00X1E 1 unit ― ― ― ― ― BCA11J028A00X2E ― ― ― 1 unit ― ― BCA11J044A00X1E ― 1 unit ― ― ― ― BCA11J044A00X2E ― ― ― ― 1 unit ― ― ― 1 unit ― ― 2 unit 2688 4224 8448 5376 8448 16896 BCA11J044A00P2E Capacity of battery (Ah・cell) 180 min. Specifications Model No. Rated output capacity (Apparent power/Active power) System A11J502A002TU A11J103A002TE N unit setting 5 kVA / 4.5 kW 10 kVA / 9 kW N+1 unit setting Power supply system — True online power supply synchronized with commercial power source 5 kVA / 4.5 kW Cooling system Forced air cooling Inverter system High-frequency PWM IEC Standard (UPS classification) AC Number of phase input Rated voltage VFI-SS-111 Single-phase 2 wires 200 V, 208 V, 220 V, 230 V, 240 V (User settable. Factory setting: 200 V) -40% to +15% 50Hz / 60Hz (Selectable Auto-detect or Constant frequency*2 Factory setting: Auto-detect) Acceptable voltage range *1 Rated frequency Max. capacity N unit setting N+1 unit setting AC output 5.5 kVA — Power factor 0.95 min (At rated input voltage and input voltage distorsion rate under 1%) Number of phase Single-phase 2 wires Rated voltage (same as input) Voltage accuracy 200 V, 208 V, 220 V, 230 V, 240 V (Factory setting: 200 V) Within ± 2% of rated voltage Rated frequency (same as input) Frequency range *2 On normal operation 50Hz / 60Hz Rated frequency Within ± 1, 3, 5% (Factory setting: 3%) On battery operation Voltage waveform Within 3% / 8% (Linear load / Rectifier load at rated output) Transient voltage variation Rapid load factor change Within ± 5% (0 ⇔ 100% rapid change) Power outage / recovery Rapid input voltage change Within ± 5% Within ± 5% (± 10% rapid change) N unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) N+1 unit 0.9 lag (acceptable range 0.7 (lag) to 1.0) Inverter N unit N+1 unit N unit 110% and over (Automatic swith to bypass *4) — 110% (1 min) / 118% (inst.) 220% and over (Automatic swith to bypass *4) 110% (1 min) / 118% (inst.) Bypass N+1 unit N unit — 200% (30 s) / 800% (2 cycles) 220% (1 min) / 236% (inst.) 200% (30 s) / 800% (2 cycles) N+1 unit — Small-sized sealed lead-acid battery 16 unit (12 V / 1 unit) 400% (30 s) / 160% (2 cycles) Type Composition Rated capacity Battery runtime 5 Ah / unit 5 min (Ambient Temp. of 25゜ C, Load power factor 0.8 , Default) Overcurrent protection Overload capacity Battery*3 Within ± 0.5% Sine wave Distortion factor of voltage Load power factor 11 kVA 6.2 kVA 110% and over (Automatic swith to bypass *4) 32 unit (12 V / 1 unit) Input leak current Acoustic noise (At 1m from the front of unit) 4 mA max. 45 dB max. 8 mA max. 50 dB max. Nominal heat dissipation (at rated output after full recharged) Environment Operating temperature Relative humidity Input Connector I/O Connector / Wiring Wire, etc. *5 Input wire 339 W 0゜ C to 40゜ C 20% to 90% (Non-condensing) Field wireless terminal / block: Applicable wire 20 to 4 AWG 8 mm2 (8 AWG) 730 W M6 22 mm2 Output Connector Output wire Field wireless terminal / block: Applicable wire 20 to 4 AWG 8 mm2 (8 AWG) M6 / NEMA L6-30R ×2 / NEMA L6-20R ×2 22 mm2 Grounding wire Input breaker capacity 5.5 mm2 (10 AWG) 35 A (UL489 certified unit) UL1778-4th/C22.2 No.107.3-05-2nd, CE: IEC62040-1:2008 14 mm2 80 A min. — EN62040-2 C3 : 2006, EN55022:2006 Class-A, FCC Part15 Sub partB Class-A EN62040-2:2006, EN55024:1998/A1:2001/A2:2003 — Safety standard Emission standard Immunity — The output supplied from the inverter startup (Inverter start-up type) *1 AC input voltage range changes by load factor. Load factor 70% or less: -40% to +15% / Load factor more than 70%: -20% to +15% Note that when recovering from power outages at a load factor of 70% or less, the abnormal voltage detection value (-40%) will be -20%. *2 At auto-detect frequency setting, synchronized frequency range is selectable as ± 1%, ± 3% or ± 5% (factory setting: ± 3%). Acceptable frequency range is ±8% at this setting. At constant frequency setting, output frequency is fixed to 50Hz or 60Hz without regard to input frequency. Acceptable range is from 40Hz to 120Hz at this setting. Note that when recovering from outside the acceptable range, acceptable frequency range will be±8% in either setting. The inverter will not run if input frequency is not within the set value (±1%, ±3%, ±5%) of the synchronized frequency range. *3 Battery runtime can be extended through the addition of optional battery boxes. Contact us for details. *4 A conditions to switch to bypass synchronously are as follows. Frequency auto-detect setting is selected.・Input frequency is in the synchronized range and input voltage is in the rated voltage range. *5 Transfer signal: (1) Contact signal: DSUB15 (female) fixing screw M3 (2) PC interface: DSUB9 (male) fixing screw #4-40UNC Remote control: Spring clamp terminal block Applicable wires: 26 AWG to 20 AWG ■ UL-certified and CE-marking Line up UL / CE 5 kVA : A11J502A002TU ― 10 kVA : A11J103A002TE only 5kVA type Battery Box ― Battery Cabinet Installation of battery box and cabinet must be done by UL-certified stuff when it is treated as an UL-certified and CE-marking product. 130 480 115 443 435 700 435 I 190 Dimensions : mm Mass 61 kg Horizontal / Rack mounting Vertical 130 I Vertical 90 262 700 90 443 435 435 190 322 262 130 480 115 115 443 435 700 435 700 700 I II I Horizontal / Rack mounting 480 Mass 61 kg Mass 124 kg (Without a battery pack 54 kg) Paint color: Black (Munsell N1.5) Horizontal / Rack mounting Vertical 700 90 Option Dimensions : mm 700 90 I II I 262 443 435 ■ Battery Box [Only 5 kVA type is UL certified and CE marking] 435 Dimensions : mm 480 Width Mass Depth*1 Height 435 700+80 130pack 54 49 Mass 124435 kg (Without a battery kg)kg BCA11J005A00UA, BCA11J005A00AE BCA11J005A00UB, BCA11J005A00BE, Black130 (Munsell 84 N1.5) 435Paint color: 700+80 kg BCA11J005A00CE 700 130 262 322 Model No. *1: Battery Box + cable cover ■ Battery Cabinet [Not UL-certified and CE-marking] Depth*1 Height BCA11J028A00X1E 1 440 700+12 544 215 kg BCA11J028A00X2E 2 440 700+12 988 415 kg BCA11J044A00X1E 3 440 870+12 544 320 kg BCA11J044A00X2E, BCA11J044A00P2E 4 440 870+12 988 620 kg Fig.1 Fig.2 440 440 700 700 440 *1: Battery Cabinet + cable cover Fig.2 440 700 Fig.3 Used for mounting the UPS onto a 19 inch rack. 544 988 133 700 48 440 544 440 Model No.: RM027 Fig.4 440 870 870 988 Fig.1 ■ Rack Support Rail 654 to 798 Rack mounting dimension A set of left and right rails. The figure shows the left rail. Eco Products Sanyo Denki’s ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste. The product units and packaging materials are designed for reduced environmental impact. We have established our own assessment criteria on the environmental impacts applicable to all processes, ranging from design to manufacture. Those products that satisfy the criteria are accredited as ECO PRODUCTS. Notes when investigating use of this product in your applications Before starting installation, assembling and use, read the “Operation Manual” carefully and use the product correctly in your applications. For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. Never modify this product or give additional processing to this product. (a) Medical equipment and other equipment that are related directly to human life. (b) Train or elevator that can give injury to human body. (c) Socially and publicly important computer systems. (d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions. Fig.3 544 Width 988 Mass Fig. 544 Dimensions : mm (inch) Model No. For the installation andmaintenance work, please consult with our company or with specialized company. This product may be regulated under export and trade control regulations of each country. During export of each product, compliance to the export regulations of each country is highly recommended. Our company shall not be responsible for damages (including but not limited to equipment downtime, power sales revenue, business interruptions, increased power purchases) resulting from use or non-use of this product and services. ※For any inquiry or consultation, please contact our sales representative. 3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020 http://www.sanyodenki.com The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. Specifications are subject to change without notice. CATALOG No.P1012B002 ‘15.5