Ausschreibungstexte der UNIGLAS

advertisement
UNIGLAS Tender Specifications
Special contractual conditions:
 Insulating glass elements
The insulating glass elements used and integrated must be CE-certified, and insulating glass units in
Germany must be Ü-certified in accordance with Bauregelliste A, Part 1, Annex 11.10.
 Glass
Clear, transparent base glass with maximum colour neutrality must be used.
 Tests
Only insulating glass produced by manufacturers that undergo a voluntary third-party inspection performed
by a test institute recognised by the GMI, KOMO or a corresponding Austrian body may be used. Evidence
of the last two test reports must be submitted upon request.
 Glass dimensions and applicable standards
EN 1991
For construction projects in Germany, the necessary glass thickness must comply with technical regulations
for the use of glazing with linear supports (TRLV) and the relevant applicable technical regulations of the
German Institute for Building Technology (DIBt) and/or comply with DIN 18008 and any relevant building
standards. The established building regulations and standards in each respective federal state shall take
precedence.
In Austria, dimensioning shall observe ÖNORM B 3716 in conjunction with the relevant applicable national
standards and legal provisions.
For construction projects in other countries, the local established building regulations and standards shall
apply.
Within the jurisdiction of European standards, the actions in accordance with the corresponding national
editions of EN 1991 must be applied. If the EN 1991 standards have not yet been implemented by building
authorities, the corresponding national standards must be observed.
The building height is _____ m above sea level, in wind zone ______, inland, postcode/zip – region:
________
Dimensions of the building b x l x h in m __________________ Exterior walls are not permeable.
DIN 1961
The general contractual terms and conditions for the execution of construction works (VOB/B) and the
general technical contractual terms and conditions (VOB/C) shall apply in their latest versions.
ÖNORM A 2060 and ÖNORM B 2110
The general provisions of a contract for services and construction
ÖNORM B 2227
Glass works - work contract
DIN 4108
The thermal transfer coefficient for glazing (nominal value Ug -value in accordance with EN 673) is specified
in the performance description. For exchanging glazing panels, the dimensioning – U-value UBW in
accordance with DIN 4108 must be considered, taking into account any necessary allowances ΔU g.
DIN EN 20140
The test value of the evaluated sound insulation value Rw,P for insulating glass is requested in the
performance description.
DIN 18361
For roof glazing, laminated safety glass must be integrated by derogation from VOB/C DIN 18361.
 Regulations
Technical regulations must be observed for the glazing design. The most important regulations are listed
below and are valid in the corresponding current versions.
-
UNIGLAS glazing guidelines, latest version
Guidelines of the Institute of Window Technology, Rosenheim
Guidelines of the Institut des Glaserhandwerks für Verglasungstechnik und Fensterbau, Hadamar
Passive house suitable components of the Dr. W. Feist Passive House Institute, Darmstadt
Standards and technical regulations introduced by building authorities
Guidelines for assessing the visual quality of glass for the building industry, issued by the Technical
Advisory Board of the Institut des Glaserhandwerks für Verglasungstechnik und Fensterbau,
Hadamar and by the Technical Committee of the Bundesverband Flachglas e. V., Troisdorf *)
- Pamphlet 006 of the Bundesverband Flachglas e. V. "Visual guidelines for systems in gaps between
panes" issued by the Technical Committee of the Bundesverband Flachglas e. V., Troisdorf
- Pamphlet 006 of the Bundesverband Flachglas e. V. "Guidelines for assessing the visual quality for
systems in insulating glass units" issued by the Technical Committee of the Bundesverband Flachglas
e. V., Troisdorf
*) in Austria shall apply contrary to the "Guidelines for assessing the visual quality of glass for the building
industry" ÖNORM B 3738 Plate glass in the building industry - Insulating glass - Requirements in
visual quality
 Technical data
-
The technical data and functional values indicated are based on information from base glass
manufacturers and were determined on the basis of each applicable product standard.
The functional values determined by test certificate refer to test pieces in the standard dimensions
intended for the test.
Corresponding deviations from the declared values occur due to the reliable tolerances of incoming
products.
Lighting and radiometric parameters must be determined in accordance with EN 410.
The thermal transfer coefficient Ug–value must be calculated with a validated programme in accordance
with EN 673. The validation must come from a notified body approved by the DIBt and/or one listed in the
NANDO list. Test certificates in accordance with EN 674 or 675 shall only be approved in justified,
exceptional cases due to the insufficient comparability of values in accordance with EN 1279-5.
Page 2 of 10
Version: Sept. 2013
The following positions shall be put out to tender with optional range of thermally improved edge bond systems:
Thermally improved spacer UNIGLAS® | TS
Thermoplastic spacer UNIGLAS® | STARTPS
Flexible spacer UNIGLAS® | STARFLS
System tendered: ……………………….. (for completion by tenderer)
Deviating designs and combinations result in modification of the stated values

UNIGLAS | SUN 62/29
Ug = 1.0 W/m2K
Light transmission
DIN EN 410
Total energy transmittance
DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6: – 16 – 4 mm float glass
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
v = 62 %
g = 29 %
v = 10 %
RW (C, Ctr): 36 (-2, -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Neutral 60/32
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
60 %
g-value:
32 %
RLa:
15 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Brilliant Blue 30/19
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
30 %
g-value:
19 %
RLa:
25 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)
Page 3 of 10
Version: Sept. 2013

UNIGLAS | SUN Platinum 25/15
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
25 %
g-value:
15 %
RLa:
28 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Nordic 70/37
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
70 %
g-value:
37 %
RLa:
14 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Neutral S 70/41
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
70 %
g-value:
41 %
RLa:
10 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Neutral 68/41
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
68 %
g-value:
41 %
RLa:
10 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)
Page 4 of 10
Version: Sept. 2013

UNIGLAS | SUN Neutral 68/37
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
68 %
g-value:
37 %
RLa:
10 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Neutral 59/47
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
59 %
Total energy transmittance DIN EN 410
g-value:
47 %
Outward light reflection
DIN EN 410
RLa:
19 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Scandic 53/27
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements

T L:
53 %
g-value:
27 %
RLa:
17 %
RW (C, Ctr): 36 (-2; -5) dB
UNIGLAS | SUN Neutral 50/27
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
50 %
g-value:
27 %
RLa:
18 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)
Page 5 of 10
Version: Sept. 2013

UNIGLAS | SUN Neutral S 40/24
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
40 %
g-value:
24 %
RLa:
16 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Office 40/22
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
40 %
g-value:
22 %
RLa:
16 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN HC Silver 56/45
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
56 %
Total energy transmittance DIN EN 410
g-value:
45 %
Outward light reflection
DIN EN 410
RLa:
37 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Silver 50/31
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
50 %
g-value:
31 %
RLa:
39 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)
Page 6 of 10
Version: Sept. 2013

UNIGLAS | SUN Silver 43/31
Ug = 1.2 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
43 %
g-value:
31 %
RLa:
31 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Silver 40/21
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
40 %
g-value:
21 %
RLa:
33 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Brillant Blue 50/28
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
Total energy transmittance DIN EN 410
Outward light reflection
DIN EN 410
Sound insulation value
DIN EN 20140
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
T L:
50 %
g-value:
28 %
RLa:
19 %
RW (C, Ctr): 36 (-2; -5) dB
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Blue 45/36
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
45 %
Total energy transmittance DIN EN 410
g-value:
36 %
Outward light reflection
DIN EN 410
RLa:
14 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)
Page 7 of 10
Version: Sept. 2013

UNIGLAS | SUN HC Blue 36/26
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
36 %
Total energy transmittance DIN EN 410
g-value:
26 %
Outward light reflection
DIN EN 410
RLa:
18 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Blue 19/18
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
19 %
Total energy transmittance DIN EN 410
g-value:
18 %
Outward light reflection
DIN EN 410
RLa:
18 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Green 64/38
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
64 %
Total energy transmittance DIN EN 410
g-value:
38 %
Outward light reflection
DIN EN 410
RLa:
9%
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Green 47/29
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
47 %
Total energy transmittance DIN EN 410
g-value:
29 %
Outward light reflection
DIN EN 410
RLa:
17 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)
Page 8 of 10
Version: Sept. 2013

UNIGLAS | SUN HC Green 46/29
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
46 %
Total energy transmittance DIN EN 410
g-value:
29 %
Outward light reflection
DIN EN 410
RLa:
26 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements

UNIGLAS | SUN Grey 38/35
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
38 %
Total energy transmittance DIN EN 410
g-value:
35 %
Outward light reflection
DIN EN 410
RLa:
6%
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Silver Grey 28/24
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
28 %
Total energy transmittance DIN EN 410
g-value:
24 %
Outward light reflection
DIN EN 410
RLa:
22 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN HC Grey 26/26
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
26 %
Total energy transmittance DIN EN 410
g-value:
26 %
Outward light reflection
DIN EN 410
RLa:
12 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)
Page 9 of 10
Version: Sept. 2013

UNIGLAS | SUN Bronze 43/37
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
43 %
Total energy transmittance DIN EN 410
g-value:
37 %
Outward light reflection
DIN EN 410
RLa:
6%
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN HC Bronze 19/22
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
19 %
Total energy transmittance DIN EN 410
g-value:
22 %
Outward light reflection
DIN EN 410
RLa:
12 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN HC Sahara 33/31
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
33 %
Total energy transmittance DIN EN 410
g-value:
31 %
Outward light reflection
DIN EN 410
RLa:
35 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)

UNIGLAS | SUN Gold 29/28
Ug = 1.1 W/m2K
Light transmission
DIN EN 410
T L:
29 %
Total energy transmittance DIN EN 410
g-value:
28 %
Outward light reflection
DIN EN 410
RLa:
36 %
Sound insulation value
DIN EN 20140
RW (C, Ctr): 36 (-2; -5) dB
Glass structure:
external - SDR - internal
6 mm solar-control glass – 16 SDR – 4 mm float Low-E coated
Glass thicknesses according to static requirements
Thermally improved spacer UNIGLAS® | …..
System tendered: ……………………….. (for completion by tenderer)
Page 10 of 10
Version: Sept. 2013
Download