QLHZ2 Hazardous Location Induction Philips QL Induction FEATURES •• 40ºC/104ºF maximum operating ambient •• Certified for use in hazardous locations: •• •• •• •• • Class I, Div. 2 • Class II, Div. 2 • Class III 100,000-hour lamp life significantly reduces maintenance where re-lamping is inconvenient or expensive. Induction lamps provide excellent lumen maintenance–70% at 60,000 hours. 80 color rendering index (CRI). All-aluminum components dissipate heat for cooler operation. EXAMPLE Q LHZ2 - 165 - 40K •• •• •• •• •• - temperature. -25ºC/-13ºF minimum operating ambient temperature. All parts painted after fabrication to inhibit corrosion. Dark-Sky Friendly. Covered by U.S. Patent No. 6,565,238. Low EMI–complies with FCC non-consumer limits. This fixture is proudly made in the USA. FLD/CG1 - OP TIONS t t t t t SERIES LAMP COLOR TEMPERATURE DISTRIBUTION/ LENS OPTIONS/ ACCESSORIES ORDERING INFORMATION - G R AY - 120 t t FINISH OPTIONS VOLTAGE ACCESSORIES QLHZ2 Hazardous Location Induction LAMP N U ED SERIES 09 /0 1/ 15 PHILIPS QL WG Wireguard FINISH OPTIONS (Must specify) SYSTEM WATTAGELUMENS 165 165-watt 12000 LAMP COLOR TEMPERATURE (Must specify) 27K 30K 40K 2 700K 3 000K 4 000K DISTRIBUTION (Must specify with Lens) F lood 6 x 6 VOLTAGE (Must specify) 120 277 LENS (Must specify with Distribution) CG1 B lack (RAL #9004) Dark bronze (Protech #PC21462) S tandard gray (Protech #PC18367) Green (RAL #6005) S atin aluminum (RAL #9006) W hite (RAL #9003) Specify custom color 100-120V 200-277V N TI FLD/ BLK DBR GRAY GRN SLV WHT RAL#____ Clear tempered glass, 3/16” thick O 19-3/16” C SPECIFICATIONS D IS •• Housing – Fully-enclosed, .125” die-cast aluminum with premium silicone gasketing. •• Reflector – 95% reflective highly specular aluminum reflector. •• Shielding – Clear tempered glass lens (CG1). •• Finish – Super durable polyester powder coat meets and exceeds AAMA 2604 specifications for outdoor durability. •• Electrical – Three-piece QL system. Prewired at factory for easy field installation. •• Mounting – Surface mount via heavy-gauge stainless steel mounting plate, support brackets, and hardware. •• Labels & Certifications – UL/CUL listed as hazardous locations: Class I, Div. 2; Class II, Div. 2; Class III. UL/CUL listed as suitable for wet locations. NEMA 4X. IP66 certified. Meets the American National Standard for Roadway Lighting Equipment– Luminaire Vibration (ANSI C136.31-2001). Bottom View 11-11/16” 24-9/16” Weight: 46 Lbs. QUANTITY ESTIMATOR Item #: QLHZ2-165-40K-FLD/CG1 Room Size ± 50 fc. 30’ x 30’ (900 sq. ft.) 5 40’ x 40’ (1,600 sq. ft.) 9 50’ x 50’ (2,500 sq. ft.) 13 ± 75 fc. 8 13 19 ± 100 fc. 11 17 25 Calculations based on standard reflectance of 80/50/20 and a light loss factor of 1.0 with a 15’-0” ceiling height. www.hewilliams.com Information contained herein is subject to change without notice. LGV31327.010911RJ Hazardous Location | 561