FEATURES
•• 40ºC/104ºF maximum operating ambient
•• Certified for use in hazardous locations:
••
••
••
••
• Class I, Div. 2
• Class II, Div. 2
• Class III
100,000-hour lamp life significantly reduces
maintenance where re-lamping is inconvenient
or expensive.
Induction lamps provide excellent lumen
maintenance–70% at 60,000 hours.
80 color rendering index (CRI).
All-aluminum components dissipate heat for
cooler operation.
EXAMPLE
Q LHZ2
-
165
-
40K
••
••
••
••
••
-
temperature. -25ºC/-13ºF minimum operating
ambient temperature.
All parts painted after fabrication to inhibit
corrosion.
Dark-Sky Friendly.
Covered by U.S. Patent No. 6,565,238.
Low EMI–complies with FCC non-consumer
limits.
This fixture is proudly made in the USA.
FLD/CG1
-
OP TIONS
t
t
t
t
t
SERIES
LAMP
COLOR
TEMPERATURE
DISTRIBUTION/
LENS
OPTIONS/
ACCESSORIES
ORDERING INFORMATION
-
G R AY
-
120
t
t
FINISH
OPTIONS
VOLTAGE
ACCESSORIES
QLHZ2
Hazardous Location Induction
LAMP
N
U
ED
SERIES
09
/0
1/
15
PHILIPS QL
WG
Wireguard
FINISH OPTIONS (Must specify)
SYSTEM WATTAGELUMENS
165
165-watt
12000
LAMP COLOR TEMPERATURE (Must specify)
27K
30K
40K
2 700K
3 000K
4 000K
DISTRIBUTION (Must specify with Lens)
F lood 6 x 6
VOLTAGE (Must specify)
120
277
LENS (Must specify with Distribution)
CG1
B lack (RAL #9004)
Dark bronze (Protech #PC21462)
S tandard gray (Protech #PC18367)
Green (RAL #6005)
S atin aluminum (RAL #9006)
W hite (RAL #9003)
Specify custom color
100-120V
200-277V
N
TI
FLD/
BLK
DBR
GRAY
GRN
SLV
WHT
RAL#____
Clear tempered glass, 3/16” thick
O
19-3/16”
C
SPECIFICATIONS
D
IS
•• Housing – Fully-enclosed, .125” die-cast
aluminum with premium silicone gasketing.
•• Reflector – 95% reflective highly specular
aluminum reflector.
•• Shielding – Clear tempered glass lens (CG1).
•• Finish – Super durable polyester powder coat
meets and exceeds AAMA 2604 specifications for
outdoor durability.
•• Electrical – Three-piece QL system. Prewired at
factory for easy field installation.
•• Mounting – Surface mount via heavy-gauge
stainless steel mounting plate, support brackets,
and hardware.
•• Labels & Certifications – UL/CUL listed
as hazardous locations: Class I, Div. 2;
Class II, Div. 2; Class III. UL/CUL listed as
suitable for wet locations. NEMA 4X. IP66
certified. Meets the American National
Standard for Roadway Lighting Equipment–
Luminaire Vibration (ANSI C136.31-2001).
Bottom View
11-11/16”
24-9/16”
Weight: 46 Lbs.
QUANTITY ESTIMATOR
Item #: QLHZ2-165-40K-FLD/CG1
Room Size
± 50 fc.
30’ x 30’ (900 sq. ft.)
5
40’ x 40’ (1,600 sq. ft.)
9
50’ x 50’ (2,500 sq. ft.)
13
± 75 fc.
8
13
19
± 100 fc.
11
17
25
Calculations based on standard reflectance of 80/50/20 and a light