NM Consumer Units for use in Domestic Household Premises Amendment No. 3 BS 7671 CONSUMER UNITS FOR USE IN DO REGULATION 421.1.201 17th Edition Wiring Regulations Incor From January 2015 Amendment No. 3 to BS 7671 IET Wiring Regulations prescribe that within domestic (household) premises, consumer units and similar switchgear assemblies shall have their enclosures manufactured from non combustible material, or be enclosed in a cabinet or enclosure constructed of non combustible material and comply with product standard BS EN 61439-3. What are Domestic Household Premises ? Typical Domestic household premises would include single and multiple occupancy homes such as Houses, Bungalows, High Rise & Low Rise Flats, Apartments, Student lets, Sheltered Accommodation, Farmhouses, Houseboats, Static Homes, Home Office, attached Garages, Workshops and Detached Summerhouses etc. What is Non Combustible Material ? There are many types of non combustible material however, amendment 3 of the 17th Edition regulations provides an acceptable example as ferrous metal i.e. Steel Consumer Units. What is an Enclosure ? The consumer unit enclosure must be manufactured from a non combustible material so as to limit the spread of fire. An enclosure means the box, cover, door, hinges, handle and any components required to maintain the integrity of the unit. What is Similar Switchgear ? Similar switchgear is switchgear that is used for the same fundamental application ie. a circuit protection assembly with two pole isolator and one or more circuit protection devices, e.g. MCB distribution board, fuse switch, garage unit or PV switchgear etc. What are Cabinets ? Typical cabinets are meter cabinets that are normally built into the fabric of the building and that may or may not include consumer units within. If the cabinet is of an all metal construction (noncombustible), then a standard skeleton consumer unit (FAL) can be installed within. If the cabinet is of a combustible material, a metal consumer unit is required. What about Cable Entry ? As usual good workmanship and proper materials should be applied to all installation work, consumer units must be installed to achieve IP4X on the top elevation (regulation 416.2.2) and IP2XC on all other elevations. This can be achieved by use of cable entry accessories such as consumer unit pattrass or other means such as glanding. This guide to Wylex consumer units is not a suitable substitute for the standards and regulations that should always be used for all types of electrical installation design & installation work. OMESTIC HOUSEHOLD PREMISES rporating Amendment No. 3 : 2015 l All metal enclosure, no external plastic parts l Low Smoke & Fume paint l Non combustible cover blanks l Compact enclosure l Available in ‘no miss terminal’ fixed busbar versions and flexible versions l Raised & removable DIN rail / busbar assembly l Cable entry knockouts on 5 sides, top, bottom, left, right and rear l Mains tails cable entry grommet / gland for supplementary insulation similar to Class II level of protection to mains tails l Time delay RCD available for TT systems l Up to 38 way units, all designs Main Switch, High Integrity, Split Load, Dual RCD l RoHS compliant in excess of UK standards l UKAS certified to BS EN 61439-3 What about Cable Entry ? The IET on site guide also recommends that where metal consumer units are installed into TT systems the mains tails are protected against the possibility of becoming loose and making contact with the metal enclosure by incorporating into the installation 100mA time delayed (S type) RCCB protection. Furthermore in all cases (including TT) the mains tails should be protected at the point of entry into the metal enclosure e.g. by use of a mains tails gland to protect against the possibility of mechanical damage and or disturbance that could lead to tails becoming loose and making contact with the metal enclosure. CONSUMER UNITS FOR USE IN DOMESTIC HOUSEHOLD PREMISES 17th Edition Wiring Regulations Including Amendment No. 3 17th Edition Wiring Regulations Including Amendment No. 3 Amendment No3 has brought about the requirement for ‘all metal’ non combustible enclosures for consumer units and similar switchgear. This is in addition to the requirements for Additional Protection (30mA RCD) as summarised below. Within domestic household premises. l Installations should be divided up into circuits so as to take account l All socket outlets should be protected by 30mA RCD of danger and inconvenience caused by a single fault - e.g. such as a l All circuits serving or passing through a room with a fixed bath or lighting circuit*** shower should be protected by one or more 30mA RCDs** l All cables buried beneath the plaster surface of the wall or partition l Installations should be designed and arranged so as to prevent unwanted tripping of RCDs*** (at less than 50mm) should be protected by 30mA RCDs*** l Safety services such as smoke alarms should be on independent l All cables concealed in metal stud partitions (common in new circuits**** builds) should be protected by 30mA RCDs*** l Installed units must be to IP4X on top elevation & IP2XC elsewhere REGULATIONS 411.3.3 * 701.411.3.3 ** 522.6.200 series and 560.7.1***** RELATING TO : Sockets up to 20A rating All Circuits serving or passing through a room with a fixed bath or shower All circuits buried in a wall or partition at less than 50mm and without mechanical protection ADDITIONAL PROTECTION EXAMPLES Upstairs Sockets 30mA RCD Downstairs Sockets Kitchen Sockets Taking into account Cooker outlet with integral 13A socket 3.14.1 **** Garage Sockets 3.14.2 **** Plus any other sockets up to 20A rated Shower circuit Lighting circuit Heating circuit Ventilation circuit Shaver Socket Plus Other circuits Downstairs Lighting Upstairs Lighting Immersion heater Smoke Alarms Burglar Alarm (Safety service) Plus any other circuits 30mA RCDs Taking into account 3.14.1 **** 3.14.2 **** 30mA RCD Taking into account 3.14.1 **** 3.14.2 **** A The IET on site guide also recommends that where metal consumer units are installed into TT systems the mains tails are protected against the possibility of becoming loose and making contact with the metal enclosure by incorporating into the installation a 100mA time delayed (S type) RCCB protection. B Furthermore in all cases the mains tails should be protected at the point of entry into the metal enclosure by use of a mains tails gland to protect against the possibility of mechanical damage and or disturbance that could lead to tails becoming loose and making contact with the metal enclosure. * ** *** Regulation 411.3.3 socket outlets with a rated current not exceeding 20A. Regulation 701.411.3.3 Additional protection shall be provided for all circuits of the location by use of one or more 30mA RCD. Regulations in the 522.6.200 series cables concealed in a wall or partition at less than 50mm depth and without earthed mechanical protection e.g. conduit. **** Regulation 314.1 Every installation shall be divided into circuits as necessary to avoid danger and inconvenience in the event of a fault, take account of danger that may arise from the failure of a single circuit such as a lighting circuit, reduce the possibility of unwanted tripping of RCDs etc. **** Regulation 314.2 Separate circuits to be provided for parts of the installation that need to be separately controlled in such a way that those circuits are not affected by the failure of other circuits. ***** Regulation 560.7.1 Chapter 56 circuits for safety services shall be independent of other circuits. In addition Chapter 51 requires designers/installers to take account of all relevant British Standards and manufacturers instructions. For example BS5839 Part 6 is the British Standard for fire detection and alarm systems in dwellings. It states that power supplies to Grade D smoke alarms should be an independent circuit at the consumer unit, or a separately electrically protected local lighting circuit. ****** Regulation 416.2.2 requires that the installed consumer unit achieves IP4X (1mm probe) on the top elevation. All other elevations should be to IP2XC (2.5mm probe). A typical domestic household application with meter cabinets B NM All Metal Consumer Units 4 NM All Metal Duplex Consumer Units 6 FAL Skeleton Units 6 PV All Metal Micro Generation Units 7 MCBs and RCBOs 8 Accessories 9 Custom Built 10 Dimensions 11 ALL INDEPENDENT CIRCUITS Full metal Main Switch unit with RCBOs B SOME INDEPENDENT CIRCUITS Full metal High Integrity unit with RCBOs and MCBs B HALF INDEPENDENT CIRCUITS Full metal Split Load unit with RCBOs and MCBs B NO INDEPENDENT CIRCUITS Full metal Dual RCD unit with MCBs Other Amendment 3 Product Publications Switch Fuse Units for use in Domestic Household Premises (and other buildings) B Domestic Switch Fuse A TT SYSTEM All independant circuits & 100mA Time Delay RCD 30mA Earth leakage protection I S 0 Amendment 3 Meter Cabinet Metal Cased Consumer Units fo r u s e i n D o m e s t i c H o u s e h o l d P re m i s e s Meter Cabinet Metal Consumer Units NMFS Intumescents & Accessories for use in Consumer Units for Domestic Household Premises Amendment No. 3 BS 7671 NMFS Intumescents NM all metal consumer units available from January 2015 MAIN SWITCH CAT REF NM206/40 NM206/63 NM506 NM806 NM1106 NM1406 NM1906 4 MS RATING *WAYS 40A 63A 100A 100A 100A 100A 100A 2 2 5 8 11 14 19 NM All Metal Consumer Units FLEXIBLE MAIN SWITCH CAT REF NM1406 NM506FLEX NM806FLEX NM1106FLEX NM1406FLEX NM1906FLEX MS RATING *WAYS 100A 100A 100A 100A 100A 5 8 11 14 19 HIGH INTEGRITY CAT REF NMRS23206 NMRS44206 NMRS43306 NMRS33406 NMRS76206 NMRS66306 NMRS46506 NMRS55506 NMRS45606 30mA 30mA RCD WAYS RCD WAYS MCB MCB 2 4 4 3 7 6 4 5 4 MS RATING MS WAYS * TOTAL 3 4 3 3 6 6 6 5 5 100A 100A 100A 100A 100A 100A 100A 100A 100A 2 2 3 4 2 3 5 5 6 7 10 10 10 15 15 15 15 15 1 to 4 2 to 5 2 to 9 100A 100A 100A 1 to 4 2 to 5 2 to 9 7 10 15 FLEXIBLE HIGH INTEGRITY NMRS10SSLMHI NMRS7SSLMHI 1 to 4 NMRS10SSLMHI 2 to 5 NMRS15SSLMHI 2 to 9 SPLIT LOAD CAT REF NMRS12SLM NMRS2406 NMRS3306 NMRS4206 NMRS5406 NMRS4506 NMRS3606 NMRS6306 NMRS3906 NMRS4806 NMRS6606 NMRS5706 NMRS7506 NMRS8406 NMRS9306 NMRS12506 NMRS11606 NMRS10706 NMRS61106 NMRS71006 NMRS9806 NMRS8906 NMRS51206 RCD RATING MCB WAYS MS RATING *WAYS 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 2 3 4 5 4 3 6 3 4 6 5 7 8 9 12 11 10 6 7 9 8 5 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 4 3 2 4 5 6 3 9 8 6 7 5 4 3 5 6 7 11 10 8 9 12 FLEXIBLE SPLIT LOAD NMRS4506 CAT REF RCD RATING NMRS6SLM NMRS9SLM NMRS12SLM NMRS17SLM 80A 30mA 80A 30mA 80A 30mA 80A 30mA MCB WAYS MIN MAX 2 3 3 5 4 6 9 12 MS RATING 100A 100A 100A 100A * WAYS MIN MAX 2 3 3 5 4 6 9 12 * WAYS TOTAL 6 9 12 17 * RCBOs or MCBs may be fitted to non RCD protected ways depending upon the installation requirements, see page 8. Complete flush mounting consumer units available to order. DIN rail modular devices suitable for flexible consumer units only. DUAL RCD 2 x 80A 30mA RCD CAT REF NMISS3406 NMISS4606 NMISS5506 NMISS8706 MS WAYS RCD 1 MCB WAYS RCD 2 MCB WAYS TOTAL No of MCB WAYS - 3 4 5 7 4 6 5 8 7 10 10 15 5 FLEXIBLE DUAL RCD 2 x 80A 30mA RCD CAT REF RCD 1 MCB WAYS RCD 2 MCB WAYS TOTAL No of MCB WAYS - 6 Max 9 Max 6 Max 9 Max 10 15 RCD INCOMER CAT REF NMISS5506 NMRS206/40 NMRS206/63 NMRS506 NMRS806 NMRS1106 NMRM206/40 NMRM206/63 NMRM506 NMRM806 NMRM1106 NMTM506 NMTM806 NMTM1106 NMTM1406 MNTM1906 RCD RATING MCB WAYS 40A 30mA 63A 30mA 100A 30mA 100A 30mA 100A 30mA 40A 100mA 63A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA time delay 100A 100mA time delay 100A 100mA time delay 100A 100mA time delay 100A 100mA time delay 2 2 5 8 11 2 2 5 8 11 5 8 11 14 19 SPLIT LOAD WITH TIME DELAY RCD INCOMER CAT REF NMRS1106 RCD RATING NMSTM2406 NMSTM3306 NMSTM3606 NMSTM4206 NMSTM4506 NMSTM5406 NMSTM6306 NMSTM3906 NMSTM4806 NMSTM6606 NMSTM7506 NMSTM9306 NMSTM8906 NMSTM9806 NMSTM71006 NMSTM61106 NMSTM51206 MCB WAYS TD RCD RATING 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 80A 30mA 4 3 3 2 4 5 6 3 4 6 7 9 8 9 7 6 5 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA 100A 100mA *WAYS 2 3 6 4 5 4 3 9 8 6 5 3 9 8 10 11 12 FLEXIBLE SPLIT LOAD ( TIME DELAY ) CAT REF RCD RATING NMSTM9SLM NMSTM12SLM NMSTM17SLM NMSTM9SLM MCB WAYS MIN MAX 80A 30mA 80A 30mA 80A 30mA 3 3 5 6 9 12 * WAYS MIN MAX TD RCD 100A 100mA 100A 100mA 100A 100mA 3 3 5 6 9 12 * WAYS TOTAL 9 12 17 DUAL TARIFF 100A MAIN SWITCH & 100A MAIN SWITCH CAT REF NMIIX2406 NMIIX3306 NMIIX5406 NMIIX4506 NHIIX3906 NHIIX4806 NMIIX7506 NMIIX6606 NMIIX5706 NMIIX9806 NMIIX8906 NMIIX51206 NMIIX11606 MS RATING *WAYS MS RATING * WAYS 63A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 2 3 5 4 3 4 7 6 5 9 8 5 11 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 100A 4 3 4 5 9 8 5 6 7 8 9 12 6 DUAL TARIFF 100A MAIN SWITCH & 100A 30mA RCD SWITCH CAT REF NMIIX4506 NMRSX5706 NMRSX6606 NMRSX7506 NMRSX8906 NMRSX9806 RCD RATING MCB WAYS MS RATING *WAYS 100A 30mA 100A 30mA 100A 30mA 100A 30mA 100A 30mA 5 5 7 8 9 100A 100A 100A 100A 100A 7 6 5 9 8 SPLIT LOAD DUAL TARIFF 100A MAIN SWITCH & 100A 30mA RCD SWITCH CAT REF NMRS10SLMDT NMRS15SLMDT RCD RATING MCB WAYS MS RATING *WAYS 100A 30mA 100A 30mA 2-5 2-5 100A 100A 2-5 2-5 NM All Metal Consumer Units NMISS10SLM NMISS15SLM MS WAYS SPLIT LOAD DUPLEX TOP BANK MS RATING *WAYS CAT REF NMDIS88 NMDIS1111 NMDIS1414 NMDIS1919 6 100A 100A 100A 100A 80A 30mA 80A 30mA 80A 30mA 80A 30mA 8 11 14 19 HIGH INTEGRITY DUPLEX 2 xRCDS, 1x 100A MAIN SWITCH CAT REF Duplex All Metal Consumer Units & FAL Skeleton Units 8 11 14 19 BOTTOM BANK RCD RATING MCB WAYS 80A 30mA RCD WAYS BOTTOM BANK NMDRS14SSLHI NMDRS20SSLHI NMDRS26SSLHI NMDRS36SSLHI 80A 30mA RCD WAYS BOTTOM BANK - 8 11 14 19 80A 30mA RCD WAYS TOP BANK * WAYS MS Flexi Flexi Flexi Flexi Flexi Flexi Flexi Flexi TOTAL 14 20 26 36 HIGH INTEGRITY DUPLEX 3xRCDS, 1x 100A MAIN SWITCH CAT REF 80A 30mA RCD WAYS BOTTOM BANK NMDRS12HI NMDRS18HI NMDRS24HI NMDRS34HI 80A 30mA RCD WAYS BOTTOM BANK Flexi Flexi Flexi Flexi Flexi Flexi Flexi Flexi 80A 30mA RCD WAYS TOP BANK * WAYS MS Flexi Flexi Flexi Flexi Flexi Flexi Flexi Flexi TOTAL 12 18 24 34 DUAL RCD DUPLEX 2 x RCDS, 100A MAIN SWITCH CAT REF BOTTOM BANK 80A 30mA 80A 30mA RCD WAYS RCD WAYS NMDISS119 NMDISS1214 NMDIS1111 - 11 14 TOP BANK 80A 30mA MS RCD WAYS WAYS 9 12 - TOTAL 20 26 DUAL TARIFF DUPLEX CAT REF TOP BANK MS RATING *WAYS NMDIIX88 NMDIIX1111 NMDIIX1414 NMDIIX1919 CAT REF BOTTOM BANK MS RATING * WAYS 100A 100A 100A 100A 8 11 14 19 100A 100A 100A 100A 8 11 14 19 MS RATING *WAYS RCD RATING MCB WAYS 100A 100A 100A 100A 8 11 14 19 80A 30mA 80A 30mA 80A 30mA 80A 30mA 8 11 14 19 NMDISX88 NMDISX1111 NMDISX1414 NMDISX1919 MAIN SWITCH CAT REF 80A 30mA RCD WAYS 80A 30mA RCD WAYS MS RATING * WAYS TOTAL - - 100A 100A 100A 8 12 17 8 12 17 - Flexi Flexi 100A 100A Flexi Flexi 10 15 Flexi Flexi 7 Flexi Flexi 6 100A 100A 100A Flexi Flexi 2 10 13 15 Flexi Flexi 6 5 7 100A 100A 100A 100A 100A - 10 15 10 10 15 FALNH806 FALNH1206 FALNH1706 SPLIT LOAD FALNHRS10SL FALNHRS15SL HIGH INTEGRITY FALNHRS10SSL FALNHRS13SSL FALNHRS76206 DUAL SPLIT LOAD RCD FALNHISS10SL FALNHISS15SL FALNHISS4606 FALNHISS5506 FALNHISS8706 FALNHR10SL Flexi Flexi 4 5 8 RCD INCOMER CAT REF FALNHRS706 FALNHRS1106 100A 30mA RCD WAYS TOTAL 7 11 7 11 * RCBOs or MCBs may be fitted depending upon the installation requirements. For use in full metal meter cabinets (non combustible). MAIN SWITCH DUAL SUPPLY PV CONSUMER UNIT WITH MID CERTIFIED GENERATION METER CAT REF. DESCRIPTION NM15DSMPVF NM10DSMPVF NM14DSRCBMPVF NM9DSRCBMPVF 15 Way unit with dual supply isolators & 16A SP MCB 10 Way unit with dual supply isolators & 16A SP MCB 14 Way unit with dual supply isolators & 16A DP RCBO 9 Way unit with dual supply isolators & 16A DP RCBO 7 HIGH INTEGRITY DUAL SUPPLY PV CONSUMER UNIT WITH MID CERTIFIED GENERATION METER CAT REF. DESCRIPTION NM11DSMPVHI NM10DSRCBMPVHI 11 Way unit with dual supply isolators & 16A SP MCB 10 Way unit with dual supply isolators & 16A DP RCBO HIGH INTEGRITY DUAL SUPPLY P V CONSUMER UNIT NM12DSPVHI NM11DSRCBPVHI 12 Way unit with dual supply isolators & 16A SP MCB 11 Way unit with dual supply isolators & 16A DP RCBO Double Pole MCB options available on request NM11DSMPVHI SPLIT LOAD DUAL SUPPLY PV CONSUMER UNIT WITH MID CERTIFIED GENERATION METER CAT REF. DESCRIPTION NM13DSMPVSL NM8DSMPVSL NM12DSRCBMPVSL NM7DSRCBMPVSL 13 Way unit with dual supply isolators & 16A SP MCB 8 Way unit with dual supply isolators & 16A SP MCB 12 Way unit with dual supply isolators & 16A DP RCBO 7 Way unit with dual supply isolators & 16A DP RCBO DUAL RCD DUAL SUPPLY PV CONSUMER UNIT WITH MID CERTIFIED GENERATION METER NM13DSMPVSL CAT REF. DESCRIPTION NM11DSMPVDR NM6DSMPVDR NM10DSRCBMPVDR NM5DSRCBMPVDR 11 Way unit with dual supply isolators & 16A SP MCB 6 Way unit with dual supply isolators & 16A SP MCB 10 Way unit with dual supply isolators & 16A DP RCBO 5 Way unit with dual supply isolators & 16A DP RCBO Double Pole MCB options available on request P V CONSUMER UNIT Insulated metered consumer unit supplied with either Main Switch and 16A SP MCB or 16A RCBO with optional MID meter. l 63A 320V AC DP Isolator l 16A B Curve SP MCB l 40A direct read MID Meter. l Ready assembled consumer unit complete with MID Certified meter l Combined unit simplifies and speeds up installation l Complete with Isolator & MCB l Easy read permanently displayed kWh reading l Option available with RCBO or MCB NMB16MPV CAT REF. DESCRIPTION NMRCBO16BMPV NMB16MPV NMRCBO16BPV NMB16PV With DP 16A RCBO (with meter) With SP 16A MCB (with meter) With DP 16A RCBO (no meter) With SP 16A MCB (no meter) P V supplies should be connected to a dedicated circuit at the consumer unit (not share a final sub circuit) P V supplies should be connected to the supply side of the MCB at the consumer unit (not reverse fed) P V Meters must comply with MID2004/22/EC B&D or B&F Note : Surge Protection devices and Type B RCDs are available on request Photo Voltaic All Metal Consumer Units NM15DSMPVF MINIATURE CIRCUIT BREAKERS (6KA) Consumer Unit Outgoing Devices & Control Modules 8 NHXB06 NHXB16 NHXB32 NHXB50 NHXB10 NHXB20 NHXB40 B CURVE C CURVE RATING POLES MODULES NHXB06 NHXB10 NHXB16 NHXB20 NHXB25 NHXB32 NHXB40 NHXB50 NHXC03 NHXC06 NHXC10 NHXC16 NHXC20 NHXC32 NHXC40 NHXC50 3A 6A 10A 16A 20A 25A 32A 40A 50A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ACCESSORIES MCBLDX WPL MCB Locking device Padlock for MCBLDX NSBS RCBO ( combined MCB / RCD device ) NHXSBS1B06 NHXSBS1B16 NHXSBS1B32 NHXSBS1B50 NHXSBS1B10 NHXSBS1B20 NHXSBS1B40 B CURVE C CURVE RCD RATING POLES MODULES NHXSBS1B06 NHXSBS1B10 NHXSBS1B16 NHXSBS1B20 NHXSBS1B32 NHXSBS1B40 NHXSBS1B50 NHXSBS1C06 NHXSBS1C10 NHXSBS1C16 NHXSBS1C20 NHXSBS1C32 NHXSBS1C40 NHXSBS1C50 6A 10A 16A 20A 32A 40A 50A 30mA 30mA 30mA 30mA 30mA 30mA 30mA 1 1 1 1 1 1 1 1 1 1 1 1 1 1 WRCBL6C2+ WRCBL10C2+ WRCBL16C2+ WRCBL20C2+ WRCBL32C2+ 6A 10A 16A 20A 32A 30mA 30mA 30mA 30mA 30mA 2 2 2 2 2 2 2 2 2 2 WRCBL40C2+ 40A 30mA 2 2 - CURRENT RATING + Suitable for flexible comb busbar consumer units only DIN RAIL MODULAR DEVICES FOR USE IN + UNITS & FLEXIBLE UNITS MESB-40NO CAT REF PRODUCT ME242/230 SMSCD11 TMSCD21 TMTCD22 MESB-20NO MESB-24NO MESB-40NO MESB-63NO MTS8 TRMSCT31 TRMSCT11 SMSCT11 Staircase timer Digital time clock 1 channel 1xNO/NC contact 16A Digital time clock 1 channel 1xNO contact 16A Digital time clock 2 channel 24 hour 7Day prog 20A 2 pole contactor 24A 4 pole contactor 40A 4 pole contactor 63A 4 pole contactor Bell transformer 12V 8VA Disc type time clock 1 channel 1xNC contact 16A Disc type time clock 1 channel 1xNC contact 16A Disc type time clock 1 channel 1xNO contact 16A MODULE 1 1 2 2 1 2 3 3 2 3 3 1 When fitting in NH Consumer Units contact Wylex technical services department NH ACCESSORIES NMMB NHB1PP CAT REF PRODUCT NMMB NHB1PP NHET25 WPL NH13CBKIT Metal blanking plate - Twist fit 1 Blanking plate - Busbar & cover (insulated 960ºC) 1 25mm Earth Terminal Padlock for NHLDK & MCBLDX 13 pin comb busbar c/w labels and 5 protection covers MODULE FLUSH MOUNTING KITS FOR NM CAT REF PRODUCT NM07FLA NM10FLA NM13FLA NM16FLA NM21FLA 7 module flush kit assembly 10 module flush kit assembly 13 module flush kit assembly 16 module flush kit assembly 21 module flush kit assembly 9 For use on upgrading NM metal units only Accessories NM CONSUMER UNIT PATTRESSES CAT REF TOP/BOTTOM LEFT/RIGHT CABLE ENTRY ENCLOSURE WIDTH DEPTH MNSPE-6462/BNR MNSPE-6462/CNR MNSPE-6462/DNR MNSPE-6462/ENR MNSPE-6462/FNR MNSPE6668/7NR MNSPE6668/10NR MNSPE6668/13NR MNSPE6668/16NR MNSPE6668/21NR 7 Module 10 Module 13 Module 16 Module 21 Module 16mm 16mm 16mm 16mm 16mm For use with NM consumer units. Allows surface cable entry through rear knockouts and automatically maintains enclosure IP rating to comply with BS7671 and BSEN61439-3 • Cable entry slot may be positioned top or bottom, or left/right ACCESSORIES CAT REF PRODUCT EIU Moulded cable gland kit for metal consumer unit to provide additional support and supplementary insulation similar to Class II construction for the incoming cables. Suitable for 16mm2 or 25mm2 cable 32mm knockout NH UPGRADE / REPLACEMENT COVER CAT REF PRODUCT NH7/MCLA255G NH10/MCLA255G NH13/MCLA255G NH16/MCLA255G NH21/MCLA255G 7 module cover assembly 10 module cover assembly 13 module cover assembly 16 module cover assembly 21 module cover assembly For use on upgrading existing NH metal units only (replacing cover, plastic visor and hinges). Colour Grey RAL 7035 RCCB CAT REF PRODUCT P.O.A 100A 100mA time delay RCCB Products made to order. Contact Wylex technical Also see data on page 3, items A & B CUSTOM BUILT To meet the ever changing requirements and designs of the modern electrical installation, Wylex offers a service to the electrical installer for all the catalogued NM range of products - Consumer Units, and Distribution Boards to be modified and assembled to their own particular specification and meeting specific customer needs. The levels of adaptation may vary from the basic pre-population and assembly of outgoing protective devices MCBs, RCBOs into the units with personalised labelling, to the complete customisation and wiring of additional accessory devices within a unit:for example meters, energy monitors, control switching equipment:- contactors, relays and timers, and over voltage surge protection devices plus almost any other DIN rail mounted piece of electrical accessory equipment that is available. This Custom Built service can save time on site, reduce labour costs, and help achieve early completion & ultimately save money for the installer of these units. Custom built metal consumer unit with circuit protection and control devices fitted METAL CONSUMER UNITS D DIMENSIONS 185(H) 130(W) 104(D) 4 MODULE 121 98 261 200 255 NM206/40 NM206/63 NMRS206/40 NMRS206/63 11 DIMENSIONS D=188mm(7.4"), E=138mm(4.2") 7 MODULE NMRS506 NMRM506 DIMENSIONS D=241mm(9.5"), E=160mm(6.3") 10 MODULE NMRM806 NM10ED6 NMRS2406 NMRS3306 E NMRS4206 NMRS6SLM NM806 NMRS806 NMSTM2406 NMSTM3306 NMTM806 DIMENSIONS D=292mm(11.5"), E=210mm(8.3") 13 MODULE NMRM1106 NMSTM3606 NM1106 NMRS4506 NMSTM5406 NM806+3 NMRSS5406 NMRS9SLM NMIIX2406 NMRS806+3 NMRS1106 NMRS806+3 NMRS5406 NM13ED6 NMSTM4506 NMRS6306 NMTM1106 NMIIX3306 NMRS23206 NMRS7SSLMHI DIMENSIONS D=343mm(13.5"), E=260.4mm(10.2") 16 MODULE NM1406 NMRS1106+3 NMRS4806 NMRS1406 NMRM1106+3 NMRS6606 NM16ED6 NMRM1406 NM806+6 NMRS3906 NMSTM7506 NMRM806+6 NMTM1406 NMRS12SLM NM1106+3 NMSTM8406 NMISS5506 NMISS10SLM NMRS44206 NMRS43306 NMRS33406 NMRS10SSLMHI DIMENSIONS D=438mm(17.2"), E=356mm(10.1") 21 MODULE NM1906 NMRS61106 NMRS9806 NMRS17SLM NMSTM9806 NM21ED6 NMSTM8906 TOP/BOTTOM CABLE ENTRY PATTRESS NMRS1906 NMRS8906 NMSTM71006 NMSTM9806 NMRS5606+6 NMTM1906 NMIIX51206 NMIIX11606 MNSPE6463/BNR MNSPE6463/CNR MNSPE6463/DNR MNSPE6463/ENR MNSPE6463/FNR 7 Module 10 Module 13 Module 16 Module 21 Module 255 D NMISS8706 NMISS15SLM NMRS76206 NMRS66306 NMRS46506 NMRS55506 NMRS45606 NMRS15SSLMHI MNSPE6668/7NR MNSPE6668/10NR MNSPE6668/13NR MNSPE6668/16NR MNSPE6668/21NR CABLE ENTRY PATTRESS CONSUMER UNIT TOP/BOTTOM ENCLOSURE SIZE (D) CABLE ENTRY LEFT/RIGHT CABLE ENTRY 7 Module 10 Module 13 Module 16 Module 21 Module MNSPE6668/7NR MNSPE6668/10NR MNSPE6668/13NR MNSPE6668/16NR MNSPE6668/21NR 16 LEFT/RIGHT CABLE ENTRY PATTRESS 255 D 16 188mm 241mm 282mm 343mm 438mm MNSPE6463/BNR MNSPE6463/CNR MNSPE6463/DNR MNSPE6463/ENR MNSPE6463/FNR Dimensions NM506 NMTM506 NM7ED6 DUPLEX METAL F 127 94 DIMENSIONS F=241mm(9.5"), G=160mm(6.3") 10 MODULE NMDIS88 NMDIIX88 NMDISX88 500 302 Dimensions 12 NMDRS12HI NMDRS14SSLHI DIMENSIONS F=292mm(11.5"), G=210mm(8.3") 13 MODULE NMDIS1111 NMDIIX1111 NMDISX1111 NMDRS18HI NMDRS20SSLHI NMDISS119 DIMENSIONS F=343mm(13.5"), G=260mm(10.2") 16 MODULE NMDIS1414 NMDIIX1414 NMDISX1414 NMDRS24HI NMDRS26SSLHI NMDISS1214 G DIMENSIONS F=430mm(17.2"), G=235mm(10.1") 21 MODULE NMDIS1919 NMDIIX1919 NMDISX1919 NMDRS34HI NMDRS36SSLHI SKELETON A DIMENSIONS A=333mm(13.2"), B=165mm(6.5"), C=90mm(3.5”) D=230mm(9”) FALNHRS8SSL FALNHISS4606 FALNHRS10SL D FALNHISS5506 FALNHISS10SL FALNH806 B DIMENSIONS A=444mm(17.5"), B=165mm(6.5"), C=90mm(3.5”) D=230mm(9”) C FALNHRS13SSL FALNHISS15SL FALNHRS55506 FALNHRS76206 FALNH1706 FALNHISS8706 FALNHRS46506 FALNHRS66306 FALNHRS15SL FALN1206 13 Acknowledged as the market leader in the UK domestic circuit protection market Wylex offers designers & specifiers a wide range of quality products that caters for a vast array of applications including domestic (household) premises. Wylex factories operate a series of internationally recognized standards including ISO9001 for quality, OHSAS 18001 for Health & Safety and ISO14001 for Environmental Management. UK locations are home to the product management, engineering, design, quality & logistics teams. In the UK Wylex has its UKAS accredited Laboratory that carries out R&D and compliance testing on all Wylex products, these highly accredited facilities ensure that safety, quality & reliability remain consistent with UK & EU legislation regulations & Siemens internal standards, policies and practices. Wylex products are all designed manufactured and tested in accordance with the recognised BS, EN & ICC product standards, and backed by standard & extended guarantees. Wylex also operates to recognised standards for product safety & sustainability, Wylex products are RoHS and REACH compliant often in excess of the UK market standards Recycled materials are used in product packaging, and declared into a recycling scheme locally to control environmental impacts and assure that the maximum level of recycling of materials and use of recycled materials is achieved. As a Siemens company Wylex also operates a zero harm scheme within all of its manufacturing logistics & sales facilities, and is proud to have achieved a 5 star Health & Safety rating. ELECTRIUM SALES LIMITED A SIEMENS COMPANY Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Cannock WS11 0XE. eMail: info@electrium.co.uk Web: www.electrium.co.uk UK SALES Telephone: 01543 455020 Facsimile: 01543 455021 eMail: wylex.sales@electrium.co.uk TECHNICAL Telephone: 01543 438320 Facsimile: 01543 438321 eMail: wylex.technical@electrium.co.uk EXPORT SALES Telephone: +44 1543 455049 Facsimile: +44 1543 455048 eMail: export@electrium.co.uk Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Wylex. Publication No. WY2202b 11/15 Printed in England.