MCV2500 SERIES 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT SPECIFICATION SHEET FEATURES 2-way or 3-way body Control by a low or line voltage SPST or SPDT controller 100~130 VAC or 200~240VAC actuators available 1000mm lead wires Minimal actuator power consumption Pressure differential up to 3.0bar 1~90 °C fluid temperature 0~65 °C ambient temperature APPLICATION The MCV2500 series hydronic valves are designed for residential heating and cooling applications. The MCV2500 series 2-position hydronic valves are used in residential and small commercial applications to control the flow of hot and/or cold water. They consist of actuator and valve. 2-way valves are designed for ON-OFF "zone" control of domestic systems. 3-way valves can be piped for mixing valve applications to control individual fan coil, baseboard radiator in domestic central heating and/or cooling systems. 2-way valves are suitable from A to B, and 3-way valves are for mixing water from A or B to AB. Depending on the model selected they can be controlled by a low or line voltage SPST or SPDT controller, such as a room thermostat, aquastat or flow switch. ENS5002R0 KO06 2005 Contents Application ………………………………………………… 1 Features …………………………………………………… 1 Specification ………………………………………………… 2~3 Dimensions ………………………………………………… 3 Installation …………………………………………………. 4 Wiring Diagram ……………………………………………… 4 1 MCV2500 SERIES HYDRONIC VALVE SPECIFICATION Voltage : AC110/220V±10%, 50/60Hz Pipe connection : PT Colour-coded label : Green, Black, White Maximum pressure : 16bar max. Control Performance : SPST/SPDT control Electrical termination : with integral 1000mm lead-wire cable Power consumption Operational life Timing Ambient Temperature : 0 ~ 65 °C : 6W at nominal voltages (during valve position change only) : Greater than 60,000 cycles (all loads) for motor and valve contacts at 110/220 V Ambient Humidity : 10 ~ 95%RH (no condensing) Storage temperature : -25 ~ 65 °C Storage Humidity : 10 ~ 95%RH (no condensing) : 20sec Table 1. Kv & Differential Pressure Valve Size Port Kv Max. operating differential pressure 2-way valve 3/4" A to B 3.0 3.0 bar 3-way valve 3/4" A to AB 3.0 3.0 bar B to AB 3.0 1.0 bar Table 2. Model selection guide (1) MCV2510AJ MC25 10 HE + MV2000 A J * MC25 : Actuator family identifier * J : 3/4”, Both internal thread * xx00 : AC220V, SPST * xx01 : AC220V, SPDT * xx10 : AC110V, SPST * xx11 : AC110V, SPDT * A : 2-way valve * M : 3-way valve * HE : 1.5Nm motor * MV2000 : valve family identifier * MCV2510AJ = MC2510HE + MV2000AJ : AC110V, SPST, 1.5Nm, 3/4”, 2-way valve (with both internal thread & PT fitting) ENS5002R0 KO06 2005 2 MCV2500 SERIES HYDRONIC VALVE Table 3. Model selection guide (2) Assembled Actuator Valve Model OS# OS# OS# MCV2500AJ MC2500HE MV2000AJ AC220V, SPST, 1.5Nm, 3/4" 2-way valve, Both internal thread, PT fitting MCV2501AJ MC2501HE MV2000AJ AC220V, SPDT, 1.5Nm, 3/4" 2-way valve, Both internal thread, PT fitting MCV2510AJ MC2510HE MV2000AJ AC110V, SPST, 1.5Nm, 3/4" 2-way valve, Both internal thread, PT fitting MCV2511AJ MC2511HE MV2000AJ AC110V, SPDT, 1.5Nm, 3/4" 2-way valve, Both internal thread, PT fitting MCV2500MJ MC2500HE MV2000MJ AC220V, SPST, 1.5Nm, 3/4" 3-way valve, Both internal thread, PT fitting MCV2501MJ MC2501HE MV2000MJ AC220V, SPDT, 1.5Nm, 3/4" 3-way valve, Both internal thread, PT fitting MCV2510MJ MC2510HE MV2000MJ AC110V, SPST, 1.5Nm, 3/4" 3-way valve, Both internal thread, PT fitting MCV2511MJ MC2511HE MV2000MJ AC110V, SPDT, 1.5Nm, 3/4" 3-way valve, Both internal thread, PT fitting Specification * Product Examples - MCV25xxAJ/MJ : Assembled model, Egg crate with 10 actuators and 10 valves - MC25xxHE : Actuator only, Egg crate with 15 actuators - MV2000AJ/MJ : Valves only, Egg crate with 30 pieces of 2-way/3-way valves DIMENSIONS Fig. 1 2-way MCV Dimensions (in mm) ENS5002R0 KO06 2005 Fig. 2 3-way MCV Dimensions (in mm) 3 MCV2500 SERIES HYDRONIC VALVE WARNING CAUTION Take care that installer is a trained experienced service person. Disconnect Power Supply before making electrical connections to prevent electrical shock and equipment damage. When installing this product: Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure it is suitable for your application. Always conduct a through checkout after installation. INSTALLATION WIRING DIAGRAM 1. The valve may be plumbed in any angle but preferably not with the actuator head below the horizontal level of the valve body. Make sure there is enough room around the actuator head for servicing or replacement. 2. The valve body can be mounted directly onto the inlet pipe. Mount the metal flange inserted in socket to outlet pipe. And then tighten the socket enough to make a seal. See Figure 1~2 for the detail dimension. 3. Mount the valve directly in the tube or pipe. Do not grip actuator head while making and tightening plumbing connections. Either hold valve body in your hand or attach adjustable spanner across the hexagonal or flat faces on the valve body. MCV2500 Series WHITE (OPEN) SPST Controller BLACK (CLOSE) L NO N NC RLY GREEN Fig. 3 Diagram with 3-wire Actuator for SPST Controller SPDT Controller WHITE MCV2500 Series (OPEN) NC NO BLACK L (CLOSE) N GREEN Fig. 4 Diagram with 3-wire Actuator for SPDT Controller Honeywell Co., Ltd. Environmental Controls 18F, Kukje Center Building 191, Hangangro-2ga, Yongsan-gu, Seoul, 140-702, Korea Tel. 82-2-799-6170/6194 Fax. 82-2-799-6188 ENS5002R0 KO06 2005 4