LEVITON UPB™ WALL SWITCH AND AUXILIARY SWITCH Cat.No.35A00-1 Installation Instructions and User’s Guide PK-93406-10-00-5AAR2243 (35I00-1) INSTALLATION AND OPERATING INSTRUCTIONS WARNINGS AND CAUTIONS • • • • WARNINGS AND CAUTIONS TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWERatcircuitbreakerorfuseandtestthatpowerisoffbeforewiring! Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations. Ifyouareunsureaboutanypartoftheseinstructions,consultanelectrician. SAVETHESEINSTRUCTIONS. For the following Models: 35A00-1Leviton600WDimmerSwitch,35A00-1CFL600WCFL/LEDDimmer,35A00-3Leviton600WNon-Dimming Switch(collectivelyreferredtoasLevitonUPB™WallSwitch,inthisdocument),and37A00-1LevitonAuxiliarySwitch NOTE:AllLevitonUPB™WallSwitchesrequireaneutral(white)connectionwire. ENGLISH • Toreducetheriskofoverheatingandpossibledamagetootherequipment,whenconfiguredasdimming-capable,DONOT installtocontrolareceptacle,amotor-operatedappliance,oratransformer-suppliedappliance. • Usethisdevicewithcopper or copper-clad wire only. • Forindooruseonly. Changing Switch Color Installation Procedure ThecoloroftheLevitonUPB™WallSwitchandAuxiliarySwitchmaybechangedtocomplementtheinteriordécor.The LevitonUPB™WallSwitchandAuxiliarySwitchissuppliedwithawhiteswitchplate.Additionalcolorsareavailable; contactyourLevitondistributorformoreinformation.Whenchangingtheswitchplate,makesurethattheswitchis disconnectedfromallpower,andproceedasfollows: 1. Besurethatallpowertotheloadhasbeendisconnectedbyturningoffthecircuitbreaker. Figure 3 – Changing Switch Color Leviton UPB™ Wall Switch Overview TheLevitonUPB™WallSwitch(Figure 1)allowsforlocalcontroloflightingbyusingtherockerswitch.Italso incorporatestheUPB™two-waypowerlinecommunicationtechnologythatgivesittheabilitytoberemotelycontrolledby UPB™compatiblecontrollers.TheLevitonUPB™WallSwitchisalsocapableoftransmittingUPB™messages(including currentlightlevel)whentherockerswitchisturnedon,turnedoff,brightened,ordimmed. 2. Ifapplicable,removethefaceplatefromtheexistingwallswitch,removetheexistingwallswitchfromthewallbox,and disconnectthewiresfromtheexistingwallswitch.Identifythe"Line","Neutral","Load"and"Traveler"(ifapplicable)wires. 3. Besurethattheair-gapswitchleverontheLevitonUPB™WallSwitchisfullyopen. 4. Remove3/4"ofinsulationfromeachofthewiresontheLevitonUPB™WallSwitch.InstalltheLevitonUPB™Wall SwitchbyconnectingwiresperwiringconfigurationshowninFigure 5. 5. InstallanyoptionalLevitonAuxiliarySwitchperwiringconfigurationshowninFigure 5. 6. Afterallconnectionshavebeenmade,becertainthatallwireconnectorsarefirmlyattachedandthereisnoexposed copper. Eachswitchcanbeconfiguredtocustomfitanindividual’slifestyleanddesires.TheLevitonDimmerSwitchiscapableof storingupto16presetlightlevelsandfaderatestocreatepowerfullightingscenes.TheLevitonNon-DimmingSwitchis usedtocontrolsuchloadsasfluorescentlightsandceilingfans. 7. GentlyplacethewiresandLevitonUPB™WallSwitchintothewallboxwiththeLEDatthetopofdevice.Usingthe suppliedscrews,attachtheLevitonUPB™WallSwitchtothewallbox. 8. Beforeinstallingthefaceplate,restorepowertothecircuit,andthenfullyclosetheair-gapswitchlever. 9. AftertestingtheLevitonUPB™WallSwitchandAuxiliarySwitchforproperlocaloperation(see Table 2 and Table 3), installaDecora®faceplateovereachswitch. Figure 1 - Leviton UPB™ Wall Switch Leviton UPB™ Wall Switch De-Rating Intwo-ganginstallations,thereisnoneedtode-ratethe35A00-1,35A00-1CFL,or35A00-3.Inthree-ganginstallations, eachswitchmustbede-ratedfrom600Wto500W. LED INDICATOR Table 1 – Leviton Wall Switch De-Rating BLACK TOP (ON/BRIGHT) LINE WHITE NEUTRAL RED LOAD YELLOW BOTTOM (OFF/DIM) CONTROL TheswitchplateattachestotheLevitonUPB™WallSwitchandAuxiliarySwitchwithtwolatchesontherightandtwoon theleft.Usingasmall-bladedscrewdriver,gentlydepresstheupperandlowerlatchononesidewhileliftinguponthe plate.Oncethelatchesarereleasedononeside,removetheswitchplatefromtheotherside. Model Device Maximum Load Next to One Dimmer Next to Two Dimmers 35A00-1 600W 600W 500W 35A00-1CFL 600W 600W 500W 35A00-3 600W 600W 500W 1. Alignthelatchesofthenewswitchplatetotheopeningsonthemountingplateandgentlysnapintoplace. GREEN GROUND INSTALLATION INSTRUCTIONS Leviton DIMMER SWITCH OPERATION TheLevitonUPB™WallSwitchiswireddirectlytothelightingcircuitandcanbecontrolledbyaddingoneormoreoptional LevitonAuxiliarySwitchesproducingmulti-waycircuits.Multi-waycircuitsmakeitpossibleforagroupofswitchesto controlthesamelightorsetoflights.Thissectionwillillustratehowtomaketheconnections. TheLevitonDimmerSwitchhasmanyconfigurableitemsthatcanbesetusingtheUPB™UPStartconfigurationsoftware. ThefollowingdescribestheoperationoftheLevitonDimmerSwitchinitsfactorydefaultconfiguration. NOTES: TheLevitonDimmerSwitchhasarockerswitchthatcanbeusedtocontrolthelightingloadasfollows. Local Rocker Switch Operation 1. RefertoFigures 1 and 2todeterminethewirecolorsforeachconnection. Table 2 - Leviton UPB™ Dimmer Switch Local Operation 2. AllLevitonUPB™WallSwitchesrequireaneutral(white)connection. Leviton Auxiliary Switch Overview The37A00-1LevitonAuxiliarySwitch(Figure2)isanoptionalcompaniondeviceusedwiththeLevitonUPB™Wall Switchformulti-waycircuits.TheLevitonAuxiliarySwitchhasarockerswitchthatcontrolsthelightingloadintheexact samemannerastherockerswitchontheLevitonUPB™WallSwitch. Figure 2 – Leviton Auxiliary Switch LED INDICATOR TOP (ON/BRIGHT) Air-Gap Switch Lever TheLevitonUPB™WallSwitchhasanair-gapswitchleverthatwillremoveallpowerfromtheloadforsafeswitch installationandlightbulbreplacement.Toactivatetheair-gapswitch,usingyourfingernail,pryopentheleveratthe groove (Figure 1).Swingtheleverfullyopensothatitisperpendiculartothebottomrim(Figure 4).Afterservicing,pushthe leverfullyclosedsothatitisparalleltothebottomrim.Thelevermustbepushedfullyclosedfornormaloperation. Figure 4 – Air-Gap Switch Lever BLACK GRAY BLUE BOTTOM (OFF/DIM) 3. TheLine(black)wiremustbeaccessiblefortheinstallationofallLevitonAuxiliarySwitches.Thiswiremaybe connectedtoeitherphaseofthe120/240Vsupply.Theblueand/orgraywireontheLevitonAuxiliarySwitchcanbe connectedtoeitherearthgroundorneutral.Theblueand/orgraywireisonlyusedtolighttheLEDontheswitch.This LEDonlyindicatesthatpowerisappliedandservesasanight-light.ConnectthebluewireonlytolighttheLEDblue. ConnectthegraywireonlytolighttheLEDred.ConnectboththebluewireandthegraywiretolighttheLEDmagenta. YELLOW Rocker Event Top Rocker Bottom Rocker Single-Tap Brightensthelightto100%(on)at defaultfaderateandrestartsauto shut-offtimer(ifapplicable). Fadethelightto0%(off)atdefault faderate. Double-Tap Snapsthelightto100%(on)and overridesautoshut-off. Snapsthelightto0%(off). Hold Startsfading(brightening)thelight towards100%atdefaultfaderate andrestartsautoshut-offtimer(if applicable). Startsfading(dimming)thelight towards0%atdefaultfaderate. Release Stopsbrighteningthelightand restartsautoshut-offtimer(if applicable). Stopsdimmingthelight. LINE *NEUTRAL (FOR RED INDICATOR) *NEUTRAL (FOR BLUE INDICATOR) CONTROL Leviton NON-DIMMING SWITCH OPERATION WEB VERSION AIR-GAP SWITCH LEVER GROOVE TheLevitonNon-DimmingSwitchhasmanyconfigurableitemsthatcanbesetusingtheUPB™UPStartconfiguration software.ThefollowingdescribestheoperationoftheLevitonNon-DimmingSwitchinitsfactorydefaultconfiguration. Local Rocker Switch Operation TheLevitonNon-DimmingSwitchhasarockerswitchthatcanbeusedtocontroltheloadasfollows. Table 3 – Leviton Non-Dimming Switch Local Operation RockerEvent TopRocker BottomRocker Single-Tap Turnstheloadonandstartsauto shut-offtimer(ifapplicable). Turnstheloadoff. SPECIFICATIONS TheLevitonUPB™WallSwitchcomesequippedwithamulti-colorLEDindicatorthatisnormallylittobluewhentheload isoff.TheLEDwillturnoffwhentheloadisturnedonorsettoanylevelabove0%.TheLEDwillflashmagentawhilethe autoshut-offtimerisrunning(iftheconfiguredLEDoptionisalwaysoff,theLEDwillremainoffduringthetimeoutperiod). RefertothefollowingTableforspecificmanufacturesandmodelnumbersofdimmableCFLandLEDbulbsapprovedfor usewiththesedimmers: 35A00-1 35A00-1CFL 35A00-3 Ifused,theLEDintheLevitonAuxiliarySwitchisalwayslit. IncandescentLoads Dimming Yes Yes Yes(configurable) Leviton AUXILIARY SWITCH OPERATION InductiveLoadsDimming Yes Yes Yes(configurable) Yes(configurable) Yes(configurable) Yes TheLevitonUPB™WallSwitchcanbeconnectedtooneormoreLevitonAuxiliarySwitchesproducingmulti-waylighting circuits.EachLevitonAuxiliarySwitchhasarockerswitchthatcontrolsthelightingloadintheexactsamemannerasthe rockerswitchontheconnectedLevitonUPB™WallSwitch,aspreviouslydescribed.Whenconnected,theLEDremains continuallyonatalltimeswhilepowerisapplied. Setup Mode ToconfiguretheLevitonUPB™WallSwitchusinganLevitoncontrolleroraPCrunningtheUPB™UPStartconfiguration software,itmustbeputintoSetupModeasfollows: Table 4 – Leviton Wall Switch Setup Model Number FlorescentLoadsNonDimming PowerMaximumDimming Operation 1 Taptherockerswitchquickly5times TheLevitonUPB™WallSwitchwillflashthelightingloadonetimeandblinkitsLEDbluetoindicatethatitis inSetupMode.Note:theswitchwillautomaticallyexitSetupmodeafter5minutes. 1 OntheLevitonUPB™WallSwitchthatyouwanttoresettofactorydefault,taptherockerswitchquickly5 times. 2 TheLevitonUPB™WallSwitchwillflashthelightingloadonetimeandblinkitsLEDbluetoindicatethatitis readytobereset. 3 Taptherockerswitchquickly10timestoresettofactorydefaultsetting. 4 TheLevitonUPB™WallSwitchwillflashthelightingloadonetimeandblinkitsLEDredtoindicatethatithas beenreset. 5 TaptherockerswitchoncemoretostoptheLEDfromblinking. YELLOW Line 120VAC, 60Hz *BLUE AND/OR GRAY CFL EcoSmart ES5R315DIM35K 15 CFL EcoSmart ES5R315DIM50K 15 CFL Feit BPESL15T/DM 15 23 5A CFL GE/EnergySmart FLE15/2/DV/R30 15 CFL GE/EnergySmart FLE15HT3/2/DV/SW 15 CFL GE/EnergySmart FLE26/2/DV/R40 26 CFL GE/EnergySmart FLE26HT3/2/DV 26 18GA LEDIndicator Yes Yes Yes CFL Litetronics 16AE5L092725 27 4.1x1.75x1.45 4.1x1.75x1.45 4.1x1.75x1.45 CFL Litetronics 18185K085141 5 CFL Litetronics 18185K088141 8 CFL Litetronics 18505A10111 11 15 InputPower 0.25lb. 0.25lb. 0.25lb. StandardJBox StandardJBox StandardJBox CFL Litetronics 18BR5E09152 120±12VAC 120±12VAC 120±12VAC CFL Litetronics/EarthMate E05129LW 5 60±3Hz 60±3Hz 60±3Hz CFL Litetronics/EarthMate E2752AJLW 27 CFL Neptun 61920-ADIM 20 -40°Fto104°F -40°Fto104°F -40°Fto104°F CFL Neptun/EarthTronics CF24SW1BDIM 24 CFL Phillips EL/APAR38 20 CFL Phillips EL/AR30DIM 16 CFL Phillips EL/AR40DIM 20 CFL Sylvania CF5EL/A15/827/DIM/BL 5 CFL Sylvania CF5EL/B10/827/C/ADP/DIM/BL 5 CFL Sylvania CF14EL/R20/DIM 14 CFL Sylvania CF14EL/TWIST/DIM 14 CFL Sylvania CF19EL/BR40/DIM 19 CFL Sylvania CF24EL/TWIST/827/DIM/RP 24 CFL TCP 2R2014DIM 14 CFL TCP 40123 23 CFL TCP 4R3016TD 16 CFL TCP CCA05 5 CFL ULA SDR23W2P-R30DIM 23 LED CooperLighting-HALO ML706830 14 LED Cree CR6-0210E 12 LED Cree CR6-0323E 12 LED EcoSmart ECO-GU24-575L-YOW 12 LED EcoSmart G2510003-005 8 LED EcoSmart R2010010-013 8 LED LemnisLighting Pharox300 6 LED Phillips 12E26A60 12.5 LED Phillips 3E12B11-E 3 LED Phillips 6E26R20 6 LED Phillips 7E26PAR20-E 7 LED Phillips 8E26A60 8 LED Sylvania LED8PAR20/DIM/827/FL36 8 LED Sylvania LED8PAR20/DIM/827/NFL25 8 LED Sylvania LED8PAR20/DIM/830/NFL25/HVP 8 LED Sylvania LED10PAR30/DIM/SG830/WSP15 10 LED Sylvania LED11PAR30/DIM/SG/830/SP10 11 LED TCP LDA153WH30K LED Toshiba 218-50053 LED Utilitech 0171150 2 LED Utilitech 0338802 7.5 LED Utilitech 0352280 3.5 NOTE:Itisnormalforthisswitchtomakeaslightbuzzingsoundduringoperation.Itisalsonormalfortheswitchandwall platetofeelwarmtothetouch. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15of theFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidential installation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedin accordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguarantee thatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrect theinterferencebyoneormoreofthefollowingmeasures: • Reorientorrelocatethereceivingantenna. • Increasetheseparationbetweentheequipmentandreceiver. • Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected. • Consultthedealeroranexperiencedradio/TVtechnicianforhelp. YELLOW WHITE *BLUE AND/OR GRAY 23 5A BLACK YELLOW ES5M10123 5A 35A00 HAI Wall Switch BLACK EcoSmart 18GA 37A00 (OPTIONAL) AUXILIARY SWITCH BLACK 5 CFL 15 BPESL23T/DIM LINE 37A00 (OPTIONAL) AUXILIARY SWITCH ES5CCDF052 Feit FCC Compliance Operation EcoSmart CFL ToresettheLevitonUPB™WallSwitchtofactorydefaultsettings: Step CFL 18GA OperatingTemperature Reset to Factory Default Settings LampWattage(W) 600W/600VA InputFrequency Setupmodeandblinkmodetakeprecedenceoverautoshut-off.Iftheautoshut-offtimerisrunning,andtheneithersetup modeorblinkmodeoccurs,theautoshut-offtimerwillberesetanddisableduntilsetuporblinkmodeexpire. 2R3015DIM Connections Mounting NOTE: LampModel EcoSmart 600W/600VA Weight 2 LampManufacturer CFL 600W/600VA CurrentMaximumNonDimming Dimensions Step CFL/LED RED 3 7.8 CFL = CompactFluorescentLamp LED = SelfBallasted,Light-EmittingDiode GREEN NEUTRAL FOR CANADA ONLY WEB VERSION LED Indicator Forwarrantyinformationand/orproductreturns,residentsofCanadashouldcontactLevitoninwritingatLeviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, PointeClaire (Quebec), Canada H9R 1E9orbytelephoneat1 800 405-5320. *CONNECTING THE BLUE AND/OR GRAY WIRE TO NEUTRAL SETS THE COLOR OF THE LED INDICATOR. CONNECT BLUE FOR BLUE INDICATOR, GRAY FOR RED INDICATOR, OR BOTH FOR MAGENTA INDICATOR. BLUE AND/OR GRAY WIRE MAY BE CONNECTED TO NEUTRAL OR EARTH GROUND. NEUTRAL IS RECOMMENDED. Usehereinofthirdpartytrademarks,servicemarks,tradenames,brandnamesand/orproductnamesarefor informationalpurposesonly,are/maybethetrademarksoftheirrespectiveowners;suchuseisnotmeanttoimply affiliation,sponsorship,orendorsement. LEVITON LIMITED WARRANTY Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that products manufactured by Leviton under the Leviton brand name (“Product”) will be free from defects in material and workmanship for the time periods indicated below, whichever is shorter: • OmniPro II and Lumina Pro: three (3) years from installation or 42 months from manufacture date. • OmniLT, Omni IIe, and Lumina: two (2) years from installation or 30 months from manufacture date. • Thermostats, Accessories: two (2) years from installation or 30 months from manufacture date. • Batteries: Rechargeable batteries in products are warranted for ninety (90) days from date of purchase. Note: Primary (non-rechargeable) batteries shipped in products are not warranted. Products with Windows® Operating Systems:Duringthewarrantyperiod,Levitonwillrestorecorruptedoperatingsystemstofactorydefaultatnocharge,providedthattheproducthasbeenusedasoriginallyintended.Installationofnon-Levitonsoftwareormodificationoftheoperatingsystemvoidsthiswarranty.Leviton’sobligationunderthisLimitedWarrantyislimitedtotherepairorreplacement,atLeviton’soption,ofProductthatfailsduetodefectinmaterial orworkmanship.LevitonreservestherighttoreplaceproductunderthisLimitedWarrantywithneworremanufacturedproduct.Leviton will not be responsible for labor costs of removal or reinstallation of Product.TherepairedorreplacedproductisthenwarrantedunderthetermsofthisLimitedWarrantyfortheremainderoftheLimitedWarrantytimeperiodorninety(90)days,whicheverislonger.ThisLimitedWarrantydoesnotcoverPC-basedsoftware products.Leviton is not responsible for conditions or applications beyond Leviton’s control.Leviton is not responsible for issues related to improper installation,including failure to follow written Installation and operation instructions,normal wear and tear,catastrophe,fault or negligence of the user or other problems external to the Product.Toviewcompletewarrantyandinstructionsforreturningproduct,pleasevisitusatwww.leviton.com. © 2013 Leviton Mfg. Co., Inc. For Technical Assistance Call: 800-824-3005 - www.leviton.com PK-93406-10-00-5AAR2243 (35I00-1)