E E-mail: info@sabcable.com Tray Cables Web site: www.sabcable.com E Chapter Item Description Page TR 600 black Type TC, MTW and WTTC UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 7 TR 600 blue Type TC, MTW and WTTC UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 8 TR 600 red Type TC, MTW and WTTC UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 9 TR 600 yellow Type TC, MTW and WTTC UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 10 TR 600 CY black Type TC, MTW and WTTC Shielded UV and oil resistant 90°C flexible tray cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 11 TR 600 CY blue Type TC, MTW and WTTC Shielded UV and oil resistant 90°C flexible tray cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 12 TR 600 CY Lean Type TC, MTW and WTTC Shielded UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 13 TR 600 Auto black Type TC, MTW and WTTC UV and oil resistant 90°c flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 14 TR 600 Auto blue Type TC, MTW and WTTC UV and oil resistant 90°c flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 15 TR 600 Auto red Type TC, MTW and WTTC UV and oil resistant 90°c flexible tray cable and machine-tool cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . E 16 TR 600 Auto CY black Type TC, MTW and WTTC Shielded UV and oil resistant 90°C flexible tray cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 17 Fordve d TR 600 HD Type WTTC Heavy Duty tray cable, UL, (UL), c(UL)us, CE . . . . . . . . . . . . . . . . . . E 18 Fordve d TR 600 C HD Type WTTC Shielded Heavy Duty tray cable, UL, (UL), c(UL)us, CE . . . . . . . . . . E 19 TR 600 T black Type TC, MTW, WTTC and Submersible Pump Cable UV and oil resistant 90°C flexible tray cable and machine-tool cable, UL, (UL), c(UL)us,CE . . . . . . . . . . . . . . . . . . . . . E 20 E 2 a p p ro a p p ro E-mail: info@sabcable.com Web site: www.sabcable.com N EW E Chapter Item Servo VFD Type MTW and WTTC Servo VFD Combo DS Type MTW and WTTC VFD Lean TR Type MTW and WTTC Description Page Variable Frequency Drive - tray cable and machine-tool cable, UL, CSA, (UL), c(UL)us,CE . . . . . . . . . . . . . E 21 Variable Frequency Drive - tray cable with overall copper screen, UL, CSA, (UL), c(UL)us, CE . . . . . . . . . . E 22 Variable Frequency Drive - shielded tray cable and machine-tool cable, UL, CSA, (UL), c(UL)us, CE . . . . . . . . . . . . E 23 VFD symmetrical Lean TR Type MTW and WTTC Variable frequency drive shielded tray cable and machine-tool cable with three tinned ground wires, UL, CSA, (UL), c(UL)us, CE . . . . . . . E 24 N EW VFD symmetrical XL Type WTTC Variable frequency drive shielded tray cable, with three insulated ground wires, (UL), c(UL)us . . . . . . . . . . . . . . . . E 25 N EW VFD Dual TR Type MTW and WTTC Variable Frequency Drive - double insulated shielded tray cable, and machine-tool cable, UL, CSA, (UL), c(UL)us, CE . . . . . . . . . . . . E 26 TR 249 Type TC and STOOW UV and oil resistant 90°C flexible tray cable and flexible Cord, UL,(UL), c(UL)us, CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 27 D 331 PLTC Type PLTC UV resistant 90°C Power Limited Circuit Cable, (UL), CE . . . . . . . . . E 28 S D 331 PLTC Type PLTC UV resistant 75°C halogen-free Power Limited Circuit Cable, (UL), CE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E 29 E-mail: info@sabcable.com Web site: www.sabcable.com E 3 TRAY CABLES Applications n Application of flexible Power and Control Tray Cable, Type TC, MTW and WTTC E 4 This special multi-conductor cable shall be permitted for use in power, lighting, control and signal circuits in accordance to the National Electrical Code (NEC), NFPA 70 Article 336. In cable trays, in raceways and in outdoor locations supported by a messenger wire in accordance to Underwriters Laboratories Inc. (UL) Standard of Safety UL 1277. For class I division 2 circuits as permitted in NEC article 501.10 (B) and for class II division 2 circuits as permitted in NEC article 502.10 (B). In industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons service the installation, and where the cable is continuously supported and protected against physical damage using mechanical protection, such as struts, angles or channels. This Tray Cable complies with the crush and impact requirements of Type TC and is identified for such use with the ER marking on the jacket. The cable is for use as exposed runs between a cable tray and the utilization device where the cable is continuously supported and protected against physical damage and is secured at intervals not exceeding 1.8 m (6 feet). Grounding for the utilization equipment shall be provided by an equipment grounding conductor within the cable. This Tray Cable shall also be permitted for use in wet locations and is resistant to moisture and corrosive agents. Cables that are surface marked ”oil resistant I” have a jacket that is for exposure to mineral oil at temperature not in excess of 60°C (140°F). Marked with ”oil resistant II” they have a jacket that is for exposure to mineral oil at temperatures not in excess of 75°C (167°C). The Type TC is flame retardant and self-extinguishing. Also sunlight resistant depending on the jacket color. MTW listed cables can be used in NFPA 79 Machine areas. MTW listed cable is for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. Exemplary applications: TR 600 Type TC, MTW and WTTC TR 600 Auto Type TC, MTW and WTTC TR 600 CY Type TC, MTW and WTTC TR 600 CY Lean Type TC, MTW and WTTC TR 600 Auto CY Type TC, MTW and WTTC TR 249 Type TC and STOOW D 331 PLTC Type PLTC S D 331 PLTC Type PLTC Recommended applications are machine tools, control systems assembly lines, CNC machining, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines Exemplary applications: TR 600 HD Type WTTC TR 600 C HD Type WTTC In hazardous (classified) areas class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in accordance with UL standard 1277 and NEC Article 336 Exemplary applications: Servo VFD Type MTW and WTTC Can be used to connect alternating current variable frequency drives Servo VFD Combo DS Type MTW and WTTC to alternating current variable frequency motors VFD Lean TR Type MTW and WTTC VFD Dual TR Type MTW and WTTC TR 600 T black, VFD symmetrical Lean TR and VFD symmetrical XL Which exemplary applications have these cables? E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES Temperature range static* Application TR 600 blue TR 600 red TR 600 yellow TR 600 CY black TR 600 CY blue TR 600 CY Lean TR 600 Auto black TR 600 Auto blue TR 600 Auto red TR 600 Auto CY TR 600 HD TR 600 C HD TR 600 T black Numbered conductors TR 600 black Cable type Selection index x x x x x x x x x x x x x x Color code acc. to US 2 Copper screen x x x Inner sheath x x x x x x UL-AWM: up to +105°C (UL) / c(UL): up to +90°C (UL) / c(UL) / CSA-AWM: up to +90°C E 5 (UL): up to +90°C (UL): up to +75°C - 25°C - 40°C Voltage 300 V Voltage (UL) / c(UL) 600 V Voltage UL-AWM / (UL) / c(UL) 600 V x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Voltage Voltage (UL) / c(UL) 600 V UL-AWM/CSA-AWM 1000 V Voltage (UL) WTTC 1000 V Testing voltage 1500 V Testing voltage 3000 V Testing voltage 4000 V Testing voltage 7500 V Standards and approvals Testing voltage cond./cond. 7500 V conductor/screen 3000 V Zero halogen acc. to DIN VDE and IEC Burning characteristics: (UL) FT4 und c(UL) FT1, FT2, FT4 Burning characteristics: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 Burning characteristics: (UL) FT4 Characteristics Oil resistance I Oil resistance I + II x Sunlight resistance x x x x x x x x x x x Exposed Runs x x x x x x x x x x x Direct Burial x x x x x x x x x x x x Machinery Area x x x x x x x x x x x x Temperature range: from x x *The temperature range for flexing is mentioned on the particular catalog page to E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES VFD symmetrical XL VFD Dual TR x x x Temperature range static* x x x x x x x Copper screen x x x x Inner sheath x UL-AWM: up to +105°C (UL) / c(UL): up to +90°C (UL) / c(UL) / CSA-AWM: up to +90°C (UL): up to +90°C (UL): up to +75°C - 25°C - 40°C Voltage 300 V Voltage (UL) / c(UL) 600 V x x Voltage Voltage UL-AWM / (UL) / c(UL) 600 V Voltage (UL) / c(UL) 600 V UL-AWM/CSA-AWM 1000 V x x x x x Voltage (UL) WTTC 1000 V x x x x x Testing voltage 1500 V Testing voltage 3000 V x Testing voltage 4000 V Testing voltage 7500 V x Standards and approvals Testing voltage cond./cond. 7500 V conductor/screen 3000 V x x x x x Zero halogen acc. to DIN VDE and IEC x Burning characteristics: (UL) FT4 und c(UL) FT1, FT2, FT4 Burning characteristics: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 x x x x x x x x x x x x Sunlight resistance x x x x x x x Exposed Runs x x x x x x x x Burning characteristics: (UL) FT4 Oil resistance I Characteristics E 6 S D 331 PLTC VFD symmetrical Lean TR x TR 249 VFD Lean TR x Color code acc. to US 2 D 331 PLTC Application x Servo VFD Combo DS Numbered conductors Servo VFD Cable type Selection index x x x x x x Oil resistance I + II Direct Burial x x x x Machinery Area x x x x Temperature range: from x x x x *The temperature range for flexing is mentioned on the particular catalog page to E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES A 79 l NFPdustria n ry for Iachine M TC, MTW TR 600 black Type and WTTC WTTC approval UV and oil resistant 90°C flexible tray cable and machine-tool cable C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 black 02841637: A BRÖCKSKES · D-VIERSEN · TR 600 black 16 AWG/37c 02841637 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/37c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 black is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 black tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 black is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: Stranding: in layers Jacket material: special sunlight and oil resistant PVC Jacket color: ä ä ä ä ä item no. Testing voltage: no. of conductors incl. ground E 7 < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. free movement: Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Outstanding features: Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 black ä UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V nominal outer-ø mm inch cable weight ≈ lbs/mft ® 18 AWG 02841803 02841804 02841805 02841807 02841809 02841812 02841816 02841818 02841819 02841825 02841827 02841837 02841850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.303 0.327 0.354 0.386 0.469 0.492 0.575 0.602 0.602 0.713 0.713 0.791 0.969 7.7 8.3 9.0 9.8 11.9 12.5 14.6 15.3 15.3 18.1 18.1 20.1 24.6 56 67 79 98 130 153 208 224 237 302 314 417 583 ® 16 AWG 02841603 02841604 02841605 02841607 02841608 02841609 3 4 5 7 8 9 0.327 0.354 0.386 0.421 0.484 0.516 8.3 9.0 9.8 10.7 12.3 13.1 69 83 99 125 149 167 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 16 AWG 02841612 02841616 02841618 02841619 02841625 02841627 02841637 02841641 02841650 02841661 12 16 18 19 25 27 37 41 50 61 0.571 0.630 0.661 0.661 0.783 0.783 0.917 0.984 1.067 1.134 14.5 16.0 16.8 16.8 19.9 19.9 23.3 25.0 27.1 28.8 210 267 295 304 390 414 579 643 757 898 ® 14 AWG 02841403 02841404 02841405 02841407 02841409 02841412 02841418 02841425 3 4 5 7 9 12 18 25 0.362 0.394 0.429 0.469 0.606 0.634 0.740 0.925 9.2 10.0 10.9 11.9 15.4 16.1 18.8 23.5 93 113 136 173 243 292 412 590 item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 12 AWG 02841203 02841204 02841205 02841207 3 4 5 7 0.413 0.449 0.492 0.567 10.5 11.4 12.5 14.4 130 160 194 265 ® 10 AWG 02841003 02841004 02841005 02841007 3 4 5 7 0.488 0.559 0.614 0.669 12.4 14.2 15.6 17.0 188 246 298 385 ® 8 AWG 02840804 02840805 4 5 0.713 0.783 18.1 19.9 401 481 ® 6 AWG 02840604 02840605 4 5 0.898 0.988 22.8 25.1 610 739 ® 4 AWG 02840404 02840405 4 5 1.079 1.193 27.4 30.3 915 1113 ® 2 AWG 02840204 02840205 4 5 1.240 1.374 31.5 34.9 1296 1575 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES approval TR 600 blue Type TC, MTW and WTTC A 79 l NFPdustria n ry for Iachine M UV and oil resistant 90°C flexible tray cable and machine-tool cable C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 blue 02861637: A BRÖCKSKES · D-VIERSEN · TR 600 blue 16 AWG/37c 02861637 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/37c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 blue is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 blue tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 blue is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 8 Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Insulation: special formulated PVC/Nylon Color code: blue conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: Stranding: in layers Jacket material: special sunlight and oil resistant PVC Jacket color: ä ä ä ä ä item no. Testing voltage: no. of conductors incl. ground < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. free movement: Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Outstanding features: Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 black ä UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V nominal outer-ø mm inch cable weight ≈ lbs/mft ® 18 AWG 02861803 02861804 02861805 02861807 02861809 02861812 02861816 02861818 02861819 02861825 02861827 02861837 02861850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.303 0.327 0.354 0.386 0.469 0.492 0.575 0.602 0.602 0.713 0.713 0.791 0.969 7.7 8.3 9.0 9.8 11.9 12.5 14.6 15.3 15.3 18.1 18.1 20.1 24.6 56 67 79 98 130 153 208 224 237 302 314 417 583 ® 16 AWG 02861603 02861604 02861605 02861607 02861608 02861609 3 4 5 7 8 9 0.327 0.354 0.386 0.421 0.484 0.516 8.3 9.0 9.8 10.7 12.3 13.1 69 83 99 125 149 167 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 16 AWG 02861612 02861616 02861618 02861619 02861625 02861627 02861637 02861641 02861650 02861661 12 16 18 19 25 27 37 41 50 61 0.571 0.630 0.661 0.661 0.783 0.783 0.917 0.984 1.067 1.134 14.5 16.0 16.8 16.8 19.9 19.9 23.3 25.0 27.1 28.8 210 267 295 304 390 414 579 643 757 898 ® 14 AWG 02861403 02861404 02861405 02861407 02861409 02861412 02861418 02861425 3 4 5 7 9 12 18 25 0.362 0.394 0.429 0.469 0.606 0.634 0.740 0.925 9.2 10.0 10.9 11.9 15.4 16.1 18.8 23.5 93 113 136 173 243 292 412 590 item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 12 AWG 02861203 02861204 02861205 02861207 3 4 5 7 0.413 0.449 0.492 0.567 10.5 11.4 12.5 14.4 130 160 194 265 ® 10 AWG 02861003 02861004 02861005 02861007 3 4 5 7 0.488 0.559 0.614 0.669 12.4 14.2 15.6 17.0 188 246 298 385 ® 8 AWG 02860804 02860805 4 5 0.713 0.783 18.1 19.9 401 481 ® 6 AWG 02860604 02860605 4 5 0.898 0.988 22.8 25.1 610 739 ® 4 AWG 02860404 02860405 4 5 1.079 1.193 27.4 30.3 915 1113 ® 2 AWG 02860204 02860205 4 5 1.240 1.374 31.5 34.9 1296 1575 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES A 79 l NFPdustria n ry for Iachine M TR 600 red Type TC, MTW and WTTC WTTC approval UV and oil resistant 90°C flexible tray cable and machine-tool cable C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 red 02981637: A BRÖCKSKES · D-VIERSEN · TR 600 red 16 AWG/37c 02981637 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/37c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 red is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 red tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 red is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Insulation: special formulated PVC/Nylon Color code: red conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: Stranding: in layers Jacket material: special sunlight and oil resistant PVC Jacket color: ä ä ä ä ä item no. Testing voltage: no. of conductors incl. ground E 9 < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. free movement: Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Outstanding features: Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 black ä UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V nominal outer-ø mm inch cable weight ≈ lbs/mft ® 18 AWG 02981803 02981804 02981805 02981807 02981809 02981812 02981816 02981818 02981819 02981825 02981827 02981837 02981850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.303 0.327 0.354 0.386 0.469 0.492 0.575 0.602 0.602 0.713 0.713 0.791 0.969 7.7 8.3 9.0 9.8 11.9 12.5 14.6 15.3 15.3 18.1 18.1 20.1 24.6 56 67 79 98 130 153 208 224 237 302 314 417 583 ® 16 AWG 02981603 02981604 02981605 02981607 02981608 02981609 3 4 5 7 8 9 0.327 0.354 0.386 0.421 0.484 0.516 8.3 9.0 9.8 10.7 12.3 13.1 69 83 99 125 149 167 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 16 AWG 02981612 02981616 02981618 02981619 02981625 02981627 02981637 02981641 02981650 02981661 12 16 18 19 25 27 37 41 50 61 0.571 0.630 0.661 0.661 0.783 0.783 0.917 0.984 1.067 1.134 14.5 16.0 16.8 16.8 19.9 19.9 23.3 25.0 27.1 28.8 210 267 295 304 390 414 579 643 757 898 ® 14 AWG 02981403 02981404 02981405 02981407 02981409 02981412 02981418 02981425 3 4 5 7 9 12 18 25 0.362 0.394 0.429 0.469 0.606 0.634 0.740 0.925 9.2 10.0 10.9 11.9 15.4 16.1 18.8 23.5 93 113 136 173 243 292 412 590 item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 12 AWG 02981203 02981204 02981205 02981207 3 4 5 7 0.413 0.449 0.492 0.567 10.5 11.4 12.5 14.4 130 160 194 265 ® 10 AWG 02981003 02981004 02981005 02981007 3 4 5 7 0.488 0.559 0.614 0.669 12.4 14.2 15.6 17.0 188 246 298 385 ® 8 AWG 02980804 02980805 4 5 0.713 0.783 18.1 19.9 401 481 ® 6 AWG 02980604 02980605 4 5 0.898 0.988 22.8 25.1 610 739 ® 4 AWG 02980404 02980405 4 5 1.079 1.193 27.4 30.3 915 1113 ® 2 AWG 02980204 02980205 4 5 1.240 1.374 31.5 34.9 1296 1575 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES approval TR 600 yellow Type TC, MTW and WTTC A 79 l NFPdustria n ry for Iachine M UV and oil resistant 90°C flexible tray cable and machine-tool cable C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 yellow 02901637: A BRÖCKSKES · D-VIERSEN · TR 600 yellow 16 AWG/37c 02901637 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/37c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 yellow is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 yellow tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 yellow is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 10 Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Insulation: special formulated PVC/Nylon Color code: yellow conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: Stranding: in layers Jacket material: special sunlight and oil resistant PVC Jacket color: ä ä ä ä ä item no. Testing voltage: no. of conductors incl. ground < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. free movement: Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Outstanding features: Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 black ä UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V nominal outer-ø mm inch cable weight ≈ lbs/mft ® 18 AWG 02901803 02901804 02901805 02901807 02901809 02901812 02901816 02901818 02901819 02901825 02901827 02901837 02901850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.303 0.327 0.354 0.386 0.469 0.492 0.575 0.602 0.602 0.713 0.713 0.791 0.969 7.7 8.3 9.0 9.8 11.9 12.5 14.6 15.3 15.3 18.1 18.1 20.1 24.6 56 67 79 98 130 153 208 224 237 302 314 417 583 ® 16 AWG 02901603 02901604 02901605 02901607 02901608 02901609 3 4 5 7 8 9 0.327 0.354 0.386 0.421 0.484 0.516 8.3 9.0 9.8 10.7 12.3 13.1 69 83 99 125 149 167 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 16 AWG 02901612 02901616 02901618 02901619 02901625 02901627 02901637 02901641 02901650 02901661 12 16 18 19 25 27 37 41 50 61 0.571 0.630 0.661 0.661 0.783 0.783 0.917 0.984 1.067 1.134 14.5 16.0 16.8 16.8 19.9 19.9 23.3 25.0 27.1 28.8 210 267 295 304 390 414 579 643 757 898 ® 14 AWG 02901403 02901404 02901405 02901407 02901409 02901412 02901418 02901425 3 4 5 7 9 12 18 25 0.362 0.394 0.429 0.469 0.606 0.634 0.740 0.925 9.2 10.0 10.9 11.9 15.4 16.1 18.8 23.5 93 113 136 173 243 292 412 590 item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 12 AWG 02901203 02901204 02901205 02901207 3 4 5 7 0.413 0.449 0.492 0.567 10.5 11.4 12.5 14.4 130 160 194 265 ® 10 AWG 02901003 02901004 02901005 02901007 3 4 5 7 0.488 0.559 0.614 0.669 12.4 14.2 15.6 17.0 188 246 298 385 ® 8 AWG 02900804 02900805 4 5 0.713 0.783 18.1 19.9 401 481 ® 6 AWG 02900604 02900605 4 5 0.898 0.988 22.8 25.1 610 739 ® 4 AWG 02900404 02900405 4 5 1.079 1.193 27.4 30.3 915 1113 ® 2 AWG 02900204 02900205 4 5 1.240 1.374 31.5 34.9 1296 1575 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES A 79 l NFPdustria n ry for Iachine M TC, MTW TR 600 CY black Type and WTTC C approval Shielded UV and oil resistant 90°C flexible tray cable and machine-tool cable Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 CY black 32231612: A BRÖCKSKES · D-VIERSEN · TR 600 CY black 16 AWG/12c 32231612 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/12c 600V flexing AWM Style 21179 600V c(UL) Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C TR 600 CY black is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. An overall tinned copper braid is recommended whenever electrical interference distorts signal transmission, or when EMI emissions need to be suppressed. TR 600 CY black tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 CY black is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Conductor: Insulation: Color code: Stranding: Inner jacket: Screen: Jacket material: Jacket color: ä ä ä ä ä ä item no. Technical data: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 special formulated PVC/Nylon black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors in layers special formulated PVC, color black tinned copper braiding special sunlight and oil resistant PVC black Voltage: Testing voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Min. bending radius fixed installation: free movement: 5 x O.D. 10 x O.D. E 11 Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Outstanding features: Sunlight resistance: yes Exposed Runs: yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 18 AWG 32231803 32231804 32231805 32231807 32231809 32231812 32231816 32231818 32231819 32231825 32231827 32231837 32231850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.358 0.382 0.409 0.449 0.559 0.591 0.677 0.705 0.705 0.815 0.815 0.937 1.098 9.1 9.7 10.4 11.4 14.2 15.0 17.2 17.9 17.9 20.7 20.7 23.8 27.9 79 92 107 136 188 226 298 325 331 411 425 573 758 ® 16 AWG 32231603 32231604 32231605 32231607 32231608 32231609 32231612 32231616 3 4 5 7 8 9 12 16 0.382 0.409 0.449 0.484 0.583 0.614 0.673 0.732 9.7 10.4 11.4 12.3 14.8 15.6 17.1 18.6 95 111 138 167 222 247 302 364 item no. no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 16 AWG 32231618 32231619 32231625 32231627 32231637 32231641 32231650 32231661 18 19 25 27 37 41 50 61 0.764 0.764 0.929 0.929 1.047 1.114 1.197 1.264 19.4 19.4 23.6 23.6 26.6 28.3 30.4 32.1 400 409 546 570 748 816 946 1100 ® 14 AWG 32231403 32231404 32231405 32231407 32231409 32231412 32231418 32231425 3 4 5 7 9 12 18 25 0.417 0.457 0.492 0.559 0.709 0.736 0.886 1.055 10.6 11.6 12.5 14.2 18.0 18.7 22.5 26.8 121 154 179 234 339 389 566 760 ® 12 AWG 32231203 32231204 3 4 0.476 0.512 12.1 13.0 172 206 E-mail: info@sabcable.com item no. (UL) / c(UL): up to +90°C no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 12 AWG 32231205 32231207 5 7 0.591 0.669 15.0 17.0 269 352 ® 10 AWG 32231003 32231004 32231005 32231007 3 4 5 7 0.587 0.661 0.717 0.772 14.9 16.8 18.2 19.6 262 333 393 491 ® 8 AWG 32230804 32230805 4 5 0.815 0.929 20.7 23.6 498 627 ® 6 AWG 32230604 32230605 4 5 1.028 1.118 26.1 28.4 777 917 ® 4 AWG 32230404 32230405 4 5 1.209 1.323 30.7 33.6 1111 1327 ® 2 AWG 32230204 32230205 4 5 1.370 1.504 34.8 38.2 1519 1823 Other dimensions and colors are possible on request. Web site: www.sabcable.com WTTC TRAY CABLES approval TR 600 CY blue Type TC, MTW and WTTC Shielded UV and oil resistant 90°C flexible tray cable and machine-tool cable A 79 l NFPdustria n ry for Iachine M C ype CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 CY blue 32211612: A BRÖCKSKES · D-VIERSEN · TR 600 CY blue 16 AWG/12c 32211612 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/12c 600V flexing AWM Style 21179 600V c(UL) Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C TR 600 CY blue is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. An overall tinned copper braid is recommended whenever electrical interference distorts signal transmission, or when EMI emissions need to be suppressed. TR 600 CY blue tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 CY blue is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Conductor: E 12 Insulation: Color code: Stranding: Inner jacket: Screen: Jacket material: Jacket color: ä ä ä ä ä ä item no. Technical data: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 special formulated PVC/Nylon blue conductors with consecutive white numbers; green-yellow earth wire from 3 conductors in layers special formulated PVC, color black tinned copper braiding special sunlight and oil resistant PVC black Voltage: Testing voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Min. bending radius fixed installation: free movement: 5 x O.D. 10 x O.D. Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Outstanding features: Sunlight resistance: yes Exposed Runs: yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 18 AWG 32211803 32211804 32211805 32211807 32211809 32211812 32211816 32211818 32211819 32211825 32211827 32211837 32211850 3 4 5 7 9 12 16 18 19 25 27 37 50 0.358 0.382 0.409 0.449 0.559 0.591 0.677 0.705 0.705 0.815 0.815 0.937 1.098 9.1 9.7 10.4 11.4 14.2 15.0 17.2 17.9 17.9 20.7 20.7 23.8 27.9 79 92 107 136 188 226 298 325 331 411 425 573 758 ® 16 AWG 32211603 32211604 32211605 32211607 32211608 32211609 32211612 32211616 3 4 5 7 8 9 12 16 0.382 0.409 0.449 0.484 0.583 0.614 0.673 0.732 9.7 10.4 11.4 12.3 14.8 15.6 17.1 18.6 95 111 138 167 222 247 302 364 item no. no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 16 AWG 32211618 32211619 32211625 32211627 32211637 32211641 32211650 32211661 18 19 25 27 37 41 50 61 0.764 0.764 0.929 0.929 1.047 1.114 1.197 1.264 19.4 19.4 23.6 23.6 26.6 28.3 30.4 32.1 400 409 546 570 748 816 946 1100 ® 14 AWG 32211403 32211404 32211405 32211407 32211409 32211412 32211418 32211425 3 4 5 7 9 12 18 25 0.417 0.457 0.492 0.559 0.709 0.736 0.886 1.055 10.6 11.6 12.5 14.2 18.0 18.7 22.5 26.8 121 154 179 234 339 389 566 760 ® 12 AWG 32211203 32211204 3 4 0.476 0.512 12.1 13.0 172 206 E-mail: info@sabcable.com item no. (UL) / c(UL): up to +90°C no. of nominal outer-ø conductors inch mm incl. ground cable weight ≈ lbs/mft ® 12 AWG 32211205 32211207 5 7 0.591 0.669 15.0 17.0 269 352 ® 10 AWG 32211003 32211004 32211005 32211007 3 4 5 7 0.587 0.661 0.717 0.772 14.9 16.8 18.2 19.6 262 333 393 491 ® 8 AWG 32210804 32210805 4 5 0.815 0.929 20.7 23.6 498 627 ® 6 AWG 32210604 32210605 4 5 1.028 1.118 26.1 28.4 777 917 ® 4 AWG 32210404 32210405 4 5 1.209 1.323 30.7 33.6 1111 1327 ® 2 AWG 32210204 32210205 4 5 1.370 1.504 34.8 38.2 1519 1823 Other dimensions and colors are possible on request. Web site: www.sabcable.com WTTC TRAY CABLES A 79 l NFPdustria n ry for Iachine M TR 600 CY Lean Type TC, MTW and WTTC C approval Shielded UV and oil resistant 90°C flexible tray cable and machine-tool cable CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 CY Lean 32241625: A BRÖCKSKES · D-VIERSEN · TR 600 CY Lean 16 AWG/25c 32241625 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/25c 600V flexing AWM Style 21179 600V c(UL) Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C TR 600 CY Lean is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. An overall tinned copper braid is recommended whenever electrical interference distorts signal transmission, or when EMI emissions need to be suppressed. TR 600 CY Lean tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 CY Lean is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Testing voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Insulation: special formulated PVC/Nylon Color code: black conductors with numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: free movement: 5 x O.D. 10 x O.D. Stranding: in layers Radiation resistance: 8 x 107 cJ/kg Wrapping: PETP foil Temperature: Screen: tinned copper braiding static: UL-AWM: up to +105°C -25°C Sheath material: special sunlight and oil resistant PVC Sheath color: black (RAL 9005) Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: ä ä ä ä ä ä ä ä item no. ® 16 AWG 32241603 32241604 32241605 32241607 32241612 32241618 32241625 Flexible cable for cable tray use Oil resistance Sunlight resistance NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed no. of nominal outer-ø conductors inch mm incl. ground 3 4 5 7 12 18 25 0.346 0.374 0.406 0.449 0.606 0.697 0.819 8.8 9.5 10.3 11.4 15.4 17.7 20.8 cable weight ≈ lbs/mft 73 89 106 140 248 337 439 item no. ® 14 AWG 32241403 32241404 32241405 32241407 32241412 32241418 32241425 ® 12 AWG 32241204 32241205 32241207 no. of nominal outer-ø conductors inch mm incl. ground 3 4 5 7 12 18 25 4 5 7 0.382 0.413 0.457 0.496 0.669 0.776 0.961 0.476 0.520 0.602 9.7 10.5 11.6 12.6 17.0 19.7 24.4 12.1 13.2 15.3 cable weight ≈ lbs/mft 95 118 152 190 327 460 655 172 209 292 item no. E 13 (UL) / c(UL): up to +90°C no. of conductors incl. ground inch nominal outer-ø mm cable weight ≈ lbs/mft ® 10 AWG 32241004 32241005 32241007 4 5 7 0.594 0.650 0.705 15.1 16.5 17.9 272 329 415 ® 8 AWG 32240804 4 0.748 19.0 416 ® 6 AWG 32240604 4 0.933 23.7 626 ® 4 AWG 32240404 4 1.114 28.3 913 ® 2 AWG 32240204 4 1.276 32.4 1260 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES approval TR 600 Auto black Type TC, MTW and WTTC -flex High 9 for ry A7 ine NFP l Mach tria dus UV and oil resistant 90°C flexible tray cable and machine-tool cable which could be used in cable track In C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 Auto black 32121625: A BRÖCKSKES · D-VIERSEN · TR 600 Auto black 16 AWG/25c 32121625 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/25c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 black is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 black tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 black is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 14 Technical data: Conductor: bare copper strands acc. to IEC 60228 class 6 Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Insulation: special formulated PVC/Nylon Testing voltage: Color code: black conductors with numbers; white-blue ground wire and green-yellow earth wire from 3 conductors Min. bending radius fixed installation: < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. > 0 mm = 12 x O.D. free movement: Stranding: in layers Jacket material: special sunlight and oil resistant PVC continuous flexing: Jacket color: black Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: ä ä ä ä ä ä item no. Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed no. of conductors incl. ground inch nominal outer-ø mm ® 18 AWG 32121803 32121804 32121805 32121807 32121809 32121812 32121816 32121818 32121819 32121825 3 4 5 7 9 12 16 18 19 25 0.303 0.327 0.354 0.413 0.469 0.492 0.575 0.602 0.630 0.713 7.7 8.3 9.0 10.5 11.9 12.5 14.6 15.3 16.0 18.1 56 67 84 111 141 156 212 235 253 309 ® 16 AWG 32121603 32121604 32121605 32121607 32121608 32121609 32121612 32121616 32121618 32121619 32121625 3 4 5 7 8 9 12 16 18 19 25 0.327 0.354 0.386 0.453 0.484 0.516 0.571 0.630 0.661 0.693 0.783 8.3 9.0 9.8 11.5 12.3 13.1 14.5 16.0 16.8 17.6 19.9 71 87 101 142 163 181 218 276 304 329 406 cable weight ≈ lbs/mft item no. no. of conductors incl. ground inch ® 14 AWG 32121403 32121404 32121405 32121407 32121409 32121412 32121418 32121425 3 4 5 7 9 12 18 25 0.390 0.421 0.461 0.571 0.650 0.685 0.799 0.996 9.9 10.7 11.7 14.5 16.5 17.4 20.3 25.3 103 124 155 224 290 322 464 649 ® 12 AWG 32121203 32121204 32121205 32121207 3 4 5 7 0.425 0.465 0.539 0.630 10.8 11.8 13.7 16.0 140 173 220 288 E-mail: info@sabcable.com nominal outer-ø mm cable weight ≈ lbs/mft item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 10 AWG 32121003 32121004 32121005 32121007 3 4 5 7 0.524 0.571 0.626 0.736 13.3 14.5 15.9 18.7 199 246 302 392 ® 8 AWG 32120804 32120805 4 5 0.736 0.811 18.7 20.6 429 530 ® 6 AWG 32120604 32120605 4 5 0.898 0.988 22.8 25.1 616 737 ® 4 AWG 32120404 32120405 4 5 1.098 1.217 27.9 30.9 972 1116 ® 2 AWG 32120204 32120205 4 5 1.268 1.406 32.2 35.7 1308 1592 Other dimensions and colors are possible on request. Web site: www.sabcable.com TRAY CABLES -flex High 9 for ry A7 ine NFP l Mach tria dus TR 600 Auto blue In Type TC, MTW and WTTC WTTC approval UV and oil resistant 90°C flexible tray cable and machine-tool cable which could be used in cable track C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 Auto blue 32101625: A BRÖCKSKES · D-VIERSEN · TR 600 Auto blue 16 AWG/25c 32101625 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/25c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 blue is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 blue tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 blue is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Technical data: Conductor: bare copper strands acc. to IEC 60228 class 6 Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Insulation: special formulated PVC/Nylon Testing voltage: Color code: blue conductors with numbers; white-blue ground wire and green-yellow earth wire from 3 conductors Min. bending radius fixed installation: E 15 < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. > 0 mm = 12 x O.D. free movement: Stranding: in layers Jacket material: special sunlight and oil resistant PVC continuous flexing: Jacket color: black Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: ä ä ä ä ä ä item no. Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed no. of conductors incl. ground inch nominal outer-ø mm ® 18 AWG 32101803 32101804 32101805 32101807 32101809 32101812 32101816 32101818 32101819 32101825 3 4 5 7 9 12 16 18 19 25 0.303 0.327 0.354 0.413 0.469 0.492 0.575 0.602 0.630 0.713 7.7 8.3 9.0 10.5 11.9 12.5 14.6 15.3 16.0 18.1 56 67 84 111 141 156 212 235 253 309 ® 16 AWG 32101603 32101604 32101605 32101607 32101608 32101609 32101612 32101616 32101618 32101619 32101625 3 4 5 7 8 9 12 16 18 19 25 0.327 0.354 0.386 0.453 0.484 0.516 0.571 0.630 0.661 0.693 0.783 8.3 9.0 9.8 11.5 12.3 13.1 14.5 16.0 16.8 17.6 19.9 71 87 101 142 163 181 218 276 304 329 406 cable weight ≈ lbs/mft item no. no. of conductors incl. ground inch ® 14 AWG 32101403 32101404 32101405 32101407 32101409 32101412 32101418 32101425 3 4 5 7 9 12 18 25 0.390 0.421 0.461 0.571 0.650 0.685 0.799 0.996 9.9 10.7 11.7 14.5 16.5 17.4 20.3 25.3 103 124 155 224 290 322 464 649 ® 12 AWG 32101203 32101204 32101205 32101207 3 4 5 7 0.425 0.465 0.539 0.630 10.8 11.8 13.7 16.0 140 173 220 288 E-mail: info@sabcable.com nominal outer-ø mm cable weight ≈ lbs/mft item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 10 AWG 32101003 32101004 32101005 32101007 3 4 5 7 0.524 0.571 0.626 0.736 13.3 14.5 15.9 18.7 199 246 302 392 ® 8 AWG 32100804 32100805 4 5 0.736 0.811 18.7 20.6 429 530 ® 6 AWG 32100604 32100605 4 5 0.898 0.988 22.8 25.1 616 737 ® 4 AWG 32100404 32100405 4 5 1.098 1.217 27.9 30.9 972 1116 ® 2 AWG 32100204 32100205 4 5 1.268 1.406 32.2 35.7 1308 1592 Other dimensions and colors are possible on request. Web site: www.sabcable.com WTTC TRAY CABLES approval TR 600 Auto red Type TC, MTW and WTTC -flex High 9 for ry A7 ine NFP l Mach tria dus UV and oil resistant 90°C flexible tray cable and machine-tool cable which could be used in cable track In C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 Auto red 32111625: A BRÖCKSKES · D-VIERSEN · TR 600 Auto red 16 AWG/25c 32111625 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/25c 600V flexing AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 red is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 red tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 red is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 16 Technical data: Conductor: bare copper strands acc. to IEC 60228 class 6 Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Insulation: special formulated PVC/Nylon Testing voltage: Color code: red conductors with numbers; white-blue ground wire and green-yellow earth wire from 3 conductors Min. bending radius fixed installation: < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. > 0 mm = 12 x O.D. free movement: Stranding: in layers Jacket material: special sunlight and oil resistant PVC continuous flexing: Jacket color: black Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: ä ä ä ä ä ä item no. Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed no. of conductors incl. ground inch nominal outer-ø mm ® 18 AWG 32111803 32111804 32111805 32111807 32111809 32111812 32111816 32111818 32111819 32111825 3 4 5 7 9 12 16 18 19 25 0.303 0.327 0.354 0.413 0.469 0.492 0.575 0.602 0.630 0.713 7.7 8.3 9.0 10.5 11.9 12.5 14.6 15.3 16.0 18.1 56 67 84 111 141 156 212 235 253 309 ® 16 AWG 32111603 32111604 32111605 32111607 32111608 32111609 32111612 32111616 32111618 32111619 32111625 3 4 5 7 8 9 12 16 18 19 25 0.327 0.354 0.386 0.453 0.484 0.516 0.571 0.630 0.661 0.693 0.783 8.3 9.0 9.8 11.5 12.3 13.1 14.5 16.0 16.8 17.6 19.9 71 87 101 142 163 181 218 276 304 329 406 cable weight ≈ lbs/mft item no. no. of conductors incl. ground inch ® 14 AWG 32111403 32111404 32111405 32111407 32111409 32111412 32111418 32111425 3 4 5 7 9 12 18 25 0.390 0.421 0.461 0.571 0.650 0.685 0.799 0.996 9.9 10.7 11.7 14.5 16.5 17.4 20.3 25.3 103 124 155 224 290 322 464 649 ® 12 AWG 32111203 32111204 32111205 32111207 3 4 5 7 0.425 0.465 0.539 0.630 10.8 11.8 13.7 16.0 140 173 220 288 E-mail: info@sabcable.com nominal outer-ø mm cable weight ≈ lbs/mft item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 10 AWG 32111003 32111004 32111005 32111007 3 4 5 7 0.524 0.571 0.626 0.736 13.3 14.5 15.9 18.7 199 246 302 392 ® 8 AWG 32110804 32110805 4 5 0.736 0.811 18.7 20.6 429 530 ® 6 AWG 32110604 32110605 4 5 0.898 0.988 22.8 25.1 616 737 ® 4 AWG 32110404 32110405 4 5 1.098 1.217 27.9 30.9 972 1116 ® 2 AWG 32110204 32110205 4 5 1.268 1.406 32.2 35.7 1308 1592 Other dimensions and colors are possible on request. Web site: www.sabcable.com WTTC TRAY CABLES -flex High 9 for ry A7 ine NFP l Mach tria dus In TC, TR 600 Auto Type MTW and CY black WTTC approval Shielded UV and oil resistant 90°C flexible tray cable and machine-tool cable which could be used in cable track C Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 Auto CY black 32261612: A BRÖCKSKES · D-VIERSEN · TR 600 Auto CY black 16 AWG/12c 32261612 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 16 AWG/12c 600V flexing AWM Style 21179 600V c(UL) Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C TR 600 Auto CY is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. An overall tinned copper braid is recommended whenever electrical interference distorts signal transmission, or when EMI emissions need to be suppressed. TR 600 Auto CY tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 Auto CY is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Conductor: Insulation: Color code: Stranding: Wrapping: Inner jacket: Screen: Jacket material: Jacket color: ä ä ä ä ä ä item no. Technical data: bare copper strands acc. to IEC 60228 class 6 special formulated PVC/Nylon black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors. Also available with blue, red or other color conductors in layers non-woven tape special formulated PVC, color black tinned copper braiding special sunlight and oil resistant PVC black Voltage: Testing voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V Min. bending radius fixed installation: free movement: continuous flexing: 5 x O.D. 10 x O.D. 12 x O.D. E 17 Radiation resistance: 8 x 107 cJ/kg Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Outstanding features: Exposed Runs: yes Direct Burial: yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required NFPA 79 for Industrial Machinery New improved with WTTC WTTC: UL Subject 2277 TC: UL Standard 1277 (UL)/(cUL) listed Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 no. of conductors incl. ground inch nominal outer-ø mm ® 18 AWG 32261803 32261804 32261805 32261807 32261809 32261812 32261816 32261818 32261819 32261825 3 4 5 7 9 12 16 18 19 25 0.323 0.386 0.413 0.480 0.563 0.594 0.681 0.709 0.736 0.819 8.2 9.8 10.5 12.2 14.3 15.1 17.3 18.0 18.7 20.8 78 91 107 151 199 227 303 331 346 414 ® 16 AWG 32261603 32261604 32261605 32261607 32261608 32261609 32261612 32261616 3 4 5 7 8 9 12 16 0.386 0.413 0.453 0.547 0.587 0.618 0.677 0.736 9.8 10.5 11.5 13.9 14.9 15.7 17.2 18.7 93 110 136 198 233 241 306 368 cable weight ≈ lbs/mft item no. no. of conductors incl. ground inch ® 16 AWG 32261618 32261619 32261625 18 19 25 0.768 0.799 0.933 19.5 20.2 23.7 405 432 557 ® 14 AWG 32261403 32261404 32261405 32261407 32261409 32261412 32261418 32261425 3 4 5 7 9 12 18 25 0.441 0.476 0.520 0.665 0.740 0.776 0.929 1.106 11.2 12.1 13.2 16.9 18.8 19.7 23.6 28.1 ® 12 AWG 32261203 32261204 32261205 32261207 3 4 5 7 0.492 0.531 0.614 0.736 12.5 13.5 15.6 18.7 E-mail: info@sabcable.com nominal outer-ø mm cable weight ≈ lbs/mft item no. (UL) / c(UL): up to +90°C no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 10 AWG 32261003 32261004 32261005 32261007 3 4 5 7 0.587 0.677 0.732 0.894 14.9 17.2 18.6 22.7 260 329 391 536 132 159 192 301 346 416 609 808 ® 8 AWG 32260804 32260805 4 5 0.886 0.961 22.5 24.4 581 702 ® 6 AWG 32260604 32260605 4 5 1.031 1.122 26.2 28.5 784 918 ® 4 AWG 32260404 32260405 4 5 1.232 1.350 31.3 34.3 1125 1333 182 216 286 384 ® 2 AWG 32260204 32260205 4 5 1.402 1.539 35.6 39.1 1538 1831 Other dimensions and colors are possible on request. Web site: www.sabcable.com WTTC orrodve d F pp TRAY CABLES approval a TR 600 HD Type WTTC Heavy Duty tray cable in process C CSA Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 HD 32301604: A BRÖCKSKES · D-VIERSEN · TR 600 HD TFFN (UL) Type TC-ER 90°C 600V, Oil I/II -40°C FT4 (UL) WTTC 90°C 1000V AWM Style 21237 105°C 600V c(UL) CSA Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 600 HD is a severe duty motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 HD is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. Construction: Conductor: E 18 tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 4000 V Min. bending radius: 7.5 x O.D. Temperature: UL-AWM: up to +105°C (UL) / c(UL): -40/+90°C Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers and green-yellow earth wire Burning characteristics: Oil resistance I & II: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Stranding: in layers Exposed Runs: yes Jacket material: TPE 356 Jacket color: orange Outstanding features: item no. ä Heavy Duty Tray Cable and Control and Instrumentation Cable ä UL-AWM recognition for 105 °C ä Extreme oil resistant ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed AWG nominal outer-ø mm inch ® 32301804 ® 32301604 ® 32301404 ® 32301204 ® 32301004 ® 32300804 ® 32300604 ® 32300404 ® 32300204 18/4c 16/4c 14/4c 12/4c 10/4c 8/4c 6/4c 4/4c 2/4c 0.331 0.358 0.394 0.402 0.563 0.724 0.902 1.079 1.248 8.4 9.1 10.0 11.2 14.3 18.4 22.9 27.4 31.7 cable weight ≈ lbs/mft 64 80 109 144 229 353 454 810 1160 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com orrodve d F pp WTTC TRAY CABLES approval a TR 600 C HD Type WTTC Shielded Heavy Duty tray cable in process C CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C Marking for TR 600 C HD 32401604: A BRÖCKSKES · D-VIERSEN · TR 600 C HD TFFN (UL) Type TC-ER 90°C 600V, Oil I/II -40°C FT4 (UL) WTTC 90°C 1000V AWM Style 21237 105°C 600V c(UL) CSA Type CIC SHIELDED 90°C dry 600V FT1 FT2 FT4 C TR 600 C HD is a shielded severe duty motor supply cable for use in applications that require tray cable ratings, flexibility, chemical resistance and extreme oil resistance. This cable can be used without conduit (exposed runs). TR 600 C HD is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336. Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. Construction: Conductor: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers and green-yellow earth wire Stranding: in layers Inner jacket: PVC, color black Screen: tinned copper braiding Jacket material: TPE 356 Jacket color: orange Technical data: Voltage: UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V Testing voltage: 4000 V Min. bending radius fixed installation: free movement: 5 x O.D. 10 x O.D. Temperature: UL-AWM: up to +105°C (UL) / c(UL): -40/+90°C Burning characteristics: Oil resistance I & II: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Exposed Runs: yes Outstanding features: item no. ä Heavy Duty Tray Cable and Control and Instrumentation Cable ä UL-AWM recognition for 105 °C ä Extreme oil resistant ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed AWG nominal outer-ø mm inch ® 32401804 ® 32401604 ® 32401404 ® 32401204 ® 32401004 ® 32400804 ® 32400604 ® 32400404 ® 32400204 18/4c 16/4c 14/4c 12/4c 10/4c 8/4c 6/4c 4/4c 2/4c 0.386 0.413 0.457 0.504 0.665 0.870 1.031 1.209 1.378 9.8 10.5 11.6 12.8 16.9 22.1 26.2 30.7 35.0 cable weight ≈ lbs/mft 88 107 149 189 310 497 710 1005 1382 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com E 19 WTTC TRAY CABLES approval TR 600 T black Type TC, MTW, WTTC and Submersible Pump Cable UV and oil resistant 90°C flexible tray cable and machine-tool cable A 79 l NFPdustria n ry for Iachine M C (UL) CIC FT4 Outdoor AWM II A/B 90C 600V ROHS C Marking for TR 600 T black 92221850: A · TR 600 T black 92221850 E135319 (UL) Type TC-ER 50C 18 AWG PVC/Nylon 75C Wet or 90C Dry Sun Res Oli Res I + II Dir Bur 600V or MTW Flexing or DP-1 or WTTC 1000V Class I Div II 90C Dry -40C or Submersible Pump Cable or c(UL) CIC FT4 Outdoor AWM II A/B 90C 600V ROHS C TR 600 T black is a multi-conductor, 600 V, 90°C, UL approved, UV and oil resistant flexible tray cable. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). The reduced outer diameter permits easy handling and installation in confined areas. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 600 T black tray cable is designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 600 T black is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 20 Technical data: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Voltage: Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers; green-yellow earth wire from 3 conductors Min. bending radius fixed installation: Stranding: in layers Jacket material: special oil & tear resistant pressure extruded copolymer Jacket color: black Testing voltage: < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. free movement: Temperature: Outstanding features: static: UL-AWM: up to +105°C -40°C (UL) / c(UL): up to +90°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Flexible cable for cable tray use even where sunlight resistance and open wiring is required Exposed Runs: yes Direct Burial: yes ä NFPA 79 for Industrial Machinery Machinery Area: yes ä New improved with WTTC ä WTTC: UL Subject 2277 Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 ä TC: UL Standard 1277 ä Submersible pump rated ä item no. UL-AWM / (UL) / c(UL): 600 V (UL) WTTC: 1000 V 4000 V no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 18 AWG 92221803 92221804 92221805 92221807 92221809 92221812 92221818 92221825 92221850 3 4 5 7 9 12 18 25 50 0.284 0.306 0.318 0.355 0.393 0.438 0.545 0.619 0.861 7.2 7.8 8.1 9.0 10.0 11.1 13.8 15.7 21.9 47 57 66 85 104 131 201 264 515 ® 16 AWG 92221603 92221604 92221605 92221607 92221608 92221609 3 4 5 7 8 9 0.306 0.330 0.344 0.385 0.418 0.428 7.8 8.4 8.7 9.8 10.6 10.9 60 74 86 113 127 139 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 16 AWG 92221612 92221616 92221618 92221625 92221641 92221650 12 16 18 25 41 50 0.508 0.567 0.594 0.676 0.869 0.942 12.9 14.4 15.1 16.9 22.1 23.9 193 246 272 360 594 707 ® 14 AWG 92221403 92221404 92221405 92221407 92221409 92221412 92221418 92221425 3 4 5 7 9 12 18 25 0.341 0.369 0.385 0.433 0.483 0.572 0.672 0.808 8.6 9.4 9.8 11.0 12.3 14.5 17.1 20.5 82 102 128 159 199 274 389 555 item no. no. of conductors incl. ground nominal outer-ø mm inch cable weight ≈ lbs/mft ® 12 AWG 92221204 92221205 92221207 4 5 7 0.429 0.450 0.508 10.9 11.4 12.9 143 170 228 ® 10 AWG 92221004 92221005 92221007 4 5 7 0.480 0.502 0.630 12.2 12.8 16.0 205 236 353 ® 8 AWG 92220804 92220805 4 5 0.704 0.739 17.9 18.8 355 426 ® 6 AWG 92220603 92220604 92220605 3 4 5 0.742 0.812 0.855 18.9 20.6 21.7 389 498 602 ® 4 AWG 92220403 92220404 3 4 0.933 1.022 23.7 25.9 616 788 ® 2 AWG 92220203 92220204 3 4 1.082 1.189 27.5 30.2 881 1137 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES A 79 l NFPdustria n ry for Iachine M MTW Servo VFD Type and WTTC WTTC approval Variable frequency drive tray cable and machine-tool cable C FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Marking for Servo VFD 08520404: A BRÖCKSKES · D-VIERSEN · Servo VFD 4 AWG/4c 08520404 THHN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 4 AWG/4c 600V AWM Style 21179 1000V c(UL) Type CIC 4 AWG/4c 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Servo VFD is a flexible motor supply cable designed for automated servo systems. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the VFD rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL AWM recognized and CSA approved for 1000 Volt. The VFD is double insulated and contains an outer PVC jacket. The VFD can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations an is UV resistant. The Servo VFD can be used in indoor or outdoor applications and is rated for direct burial. Servo VFD is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Conductor: Technical data: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Voltage: (UL) / c(UL): 600 V UL-AWM/CSA-AWM: 1000 V (UL) WTTC: 1000 V Testing voltage U: 7500 V Min. bending radius: 12 x O.D. Insulation: special formulated PVC/Nylon Temperature: Color code: black conductors with consecutive white numbers and green-yellow earth wire static: UL-AWM: up to +105°C -25°C Stranding: in layers Jacket material: special sunlight and oil resistant PVC Burning characteristics: Oil resistant: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 yes Jacket color: black Sunlight resistance: yes Exposed Runs: yes Outstanding features: Direct Burial: yes Machinery Area: yes ä Interconnection of variable frequency drive control device to variable frequency motors Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 ä NFPA 79 for Industrial Machinery ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed item no. AWG nominal outer-ø mm inch ® 08521804 ® 08521604 ® 08521404 ® 08521204 ® 08521004 ® 08520804 ® 08520604 ® 08520404 ® 08520204 18/4c 16/4c 14/4c 12/4c 10/4c 8/4c 6/4c 4/4c 2/4c 0.331 0.358 0.394 0.441 0.543 0.724 0.902 1.079 1.252 8.4 9.1 10.0 11.2 13.8 18.4 22.9 27.4 31.8 (UL) / c(UL) / CSA-AWM: up to +90°C cable weight ≈ lbs/mft 67 83 113 147 223 360 558 825 1177 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com E 21 WTTC TRAY CABLES approval Servo VFD Combo DS Type MTW and WTTC A 79 l NFPdustria n ry for Iachine M Variable frequency drive tray cable and machine-tool cable with overall copper screen C 4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Marking for Servo VFD Combo DS 08530444: A BRÖCKSKES · D-VIERSEN · Servo VFD Combo DS 4 AWG/4c + 16 AWG/2pr 08530444 THHN + TFFN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 600V flexing AWM Style 21179 1000V c(UL) Type CIC SHIELDED 4 AWG/4c + 16 AWG/2pr 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Servo VFD Combo DS is a flexible shielded motor supply cable designed for automated servo systems. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the Servo VFD Combo DS rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL AWM recognized and CSA approved for 1000 Volt. The Servo VFD Combo DS has an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. The Servo VFD Combo DS can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations and is UV resistant. The Servo VFD Combo DS can be used in indoor or outdoor applications and is rated for direct burial. The combination of the braid and foil shield makes the VFD DS 100% shielded from excessive interference. Servo VFD Combo DS is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: E 22 Conductor: Technical data: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers and a green-yellow earth wire Stranding: signal conductors in pairs Screen: pairwise with alu foil, tinned copper drain wire AWG 26 and braided with tinned copper wires Voltage: (UL) / c(UL): 600 V UL-AWM/CSA-AWM: 1000 V (UL) WTTC: 1000 V Testing voltage U: conductor/conductor 7500 V conductor/screen 3000 V Min. bending radius: 12 x O.D. Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistant: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 yes Sunlight resistance: yes yes (UL) / c(UL) / CSA-AWM: up to +90°C Wrapping: pairwise with PETP foil Exposed Runs: Stranding: screened signal pair(s) and power conductors in layers Direct Burial: yes Machinery Area: yes Wrapping: non-woven tape Screen : double shield, alu foil and tinned copper braiding Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Jacket material: special sunlight and oil resistant PVC Jacket color: black item no. dimensions Outstanding features: nominal outer-ø mm inch ® 08531614 ® 08531604 ® 08531464 ® 08531414 ® 08531404 ® 08531264 ® 08531214 ® 08531204 ® 08531064 ® 08531004 ® 08530864 ® 08530804 ® 08530644 ® 08530604 ® 08530444 ® 08530404 16 AWG/4c + 18 AWG/1pr 16 AWG/4c + 14 AWG/1pr 14 AWG/4c + 18 AWG/2pr 14 AWG/4c + 18 AWG/1pr 14 AWG/4c + 14 AWG/1pr 12 AWG/4c + 18 AWG/2pr 12 AWG/4c + 18 AWG/1pr 12 AWG/4c + 14 AWG/1pr 10 AWG/4c + 18 AWG/2pr 10 AWG/4c + 14 AWG/1pr 8 AWG/4c + 18 AWG/2pr 8 AWG/4c + 14 AWG/1pr 6 AWG/4c + 16 AWG/2pr 6 AWG/4c + 14 AWG/1pr 4 AWG/4c + 16 AWG/2pr 4 AWG/4c + 14 AWG/1pr 0.469 0.516 0.693 0.504 0.555 0.724 0.563 0.610 0.756 0.689 0.937 0.878 1.043 1.024 1.217 1.157 11.9 13.1 17.6 12.8 14.1 18.4 14.3 15.5 19.2 17.5 23.8 22.3 26.5 26.0 30.9 29.4 cable weight ≈ lbs/mft 140 174 262 170 207 300 224 269 371 344 541 520 733 705 1015 982 ä Interconnection of variable frequency drive control device to variable frequency motors ä NFPA 79 for Industrial Machinery ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES A 79 l NFPdustria n ry for Iachine M VFD Lean TR Type MTW and WTTC approval Variable frequency drive - shielded tray cable and machine-tool cable C FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Marking for VFD Lean TR 08610404: A BRÖCKSKES · D-VIERSEN · VFD Lean TR 4 AWG/4c 08610404 THHN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 4 AWG/4c 600V AWM Style 21179 1000V c(UL) Type CIC SHIELDED 4 AWG/4c 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C VFD Lean TR is a flexible shielded motor supply cable designed for automated servo systems. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the VFD Lean TR rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL AWM recognized and CSA approved for 1000 Volt. The VFD Lean TR has an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. The VFD Lean TR can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations and is UV resistant. The VFD Lean TR can be used in indoor or outdoor applications and is rated for direct burial. The combination of the braid and foil shield makes the VFD Lean TR 100% shielded from excessive interference. VFD Lean TR is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Construction: Conductor: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Testing voltage U: conductor/conductor 7500 V conductor/screen 3000 V 12 x O.D. static: UL-AWM: up to +105°C -25°C non-woven tape Burning characteristics: Oil resistant: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 yes double shield, alu foil and tinned copper braiding Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Color code: black conductors with consecutive white numbers and green-yellow earth wire Stranding: in layers Wrapping: Screen: Jacket material: special sunlight and oil resistant PVC Jacket color: black Outstanding features: ä Interconnection of variable frequency drive control device to variable frequency motors ä NFPA 79 for Industrial Machinery ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed AWG nominal outer-ø mm inch 18/4c 16/4c 14/4c 12/4c 10/4c 8/4c 6/4c 4/4c 2/4c (UL) / c(UL): 600 V UL-AWM/CSA-AWM: 1000 V (UL) WTTC: 1000 V Temperature: special formulated PVC/Nylon ® 08611804 ® 08611604 ® 08611404 ® 08611204 ® 08611004 ® 08610804 ® 08610604 ® 08610404 ® 08610204 Voltage: Min. bending radius: Insulation: item no. Technical data: 0.354 0.382 0.417 0.472 0.602 0.764 0.941 1.118 1.287 9.0 9.7 10.6 12.0 15.3 19.4 23.9 28.4 32.7 (UL) / c(UL) / CSA-AWM: up to +90°C cable weight ≈ lbs/mft 75 91 120 177 278 430 633 916 1283 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com E 23 WTTC TRAY CABLES approval VFD symmetrical Type MTW and Lean TR WTTC A 79 l NFPdustria n ry for Iachine M Variable frequency drive shielded tray cable and machine-tool cable with three tinned ground wires C T2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Marking for VFD symmetrical Lean TR 08641403: A BRÖCKSKES · D-VIERSEN · VFD symmetrical Lean TR 14 AWG/3c 08641403 THHN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 14 AWG/3c 600V flexing AWM Style 21179 1000V c(UL) Type CIC SHIELDED 14 AWG/3c 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C VFD symmetrical Lean TR is a flexible shielded motor supply cable designed for automated servo systems. The VFD symmetrical Lean TR contains a symmetrical arraignment of three phase leads and three tinned copper (PE) earth wires. The symmetrical placement of three phase leads and three earth wires insures proper earthing paths and minimizes the risk of motor failure from common-mode current. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the VFD symmetrical Lean TR rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL and CSA AWM approved for 1000 Volt. The VFD symmetrical Lean TR has an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. The VFD symmetrical Lean TR can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations and is UV resistant. The VFD symmetrical Lean TR can be used in indoor or outdoor applications and is rated for direct burial. The combination of the braid and foil shield makes the VFD symmetrical Lean TR 100% shielded from excessive interference. VFD symmetrical Lean TR is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. E 24 Construction: Conductor: Technical data: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 Insulation: special formulated PVC/Nylon Color code: black conductors with consecutive white numbers Stranding: in layers with three tinned ground wires in the fillers Screen: double shield, alu foil and tinned copper braiding Jacket material: special sunlight and oil resistant PVC black Jacket color: Outstanding features: item no. ® 08641603 ® 08641403 ® 08641203 ® 08641003 ® 08640803 ® 08640603 ® 08640403 ® 08640203 ® 08640103 ä Interconnection of variable frequency drive control device to variable frequency motors ä NFPA 79 for Industrial Machinery ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä Three tinned ground wires for optimal performance AWG 16/3c 14/3c 12/3c 10/3c 8/3c 6/3c 4/3c 2/3c 1/3c ground wire n x AWG 3x 3x 3x 3x 3x 3x 3x 3x 3x 20 18 16 16 14 12 12 6 6 nominal outer-ø mm inch 0.350 0.390 0.445 0.567 0.701 0.866 1.024 1.185 1.350 Voltage: (UL) / c(UL): 600 V UL-AWM/CSA-AWM: 1000 V (UL) WTTC: 1000 V Testing voltage U: conductor/conductor 7500 V conductor/screen 3000 V Min. bending radius: 12 x O.D. Temperature: static: UL-AWM: up to +105°C -25°C Burning characteristics: Oil resistant: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 yes Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 (UL) / c(UL) / CSA-AWM: up to +90°C cable weight ≈ lbs/mft 8.9 9.9 11.3 14.4 17.8 22.0 26.0 30.1 34.3 87 118 169 260 385 801 1292 1292 1761 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com WTTC TRAY CABLES VFD symmetrical XL Type WTTC approval Variable frequency drive shielded tray cable with three insulated ground wires SHIELDED 14 AWG/3c 90°C dry 600V FT1, FT2, Marking for VFD symmetrical XL: A BRÖCKSKES · D-VIERSEN · VFD symmetrical XL 8 AWG/3c THHN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V c(UL) Type CIC SHIELDED 8 AWG/3c 90°C dry 600V FT1, FT2, FT4 VFD symmetrical XL is a flexible shielded motor supply cable designed for automated servo systems. The VFD symmetrical XL contains a symmetrical arraignment of three phase leads and three tinned copper (PE) earth wires. The symmetrical placement of three phase leads and three earth wires insures proper earthing paths and minimizes the risk of motor failure from common-mode current. This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the VFD symmetrical XL rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL approved for 1000 Volt. The VFD symmetrical XL has an outer jacket and both a foil outer jacket and aluminum foil shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. The VFD symmetrical XL can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations and is UV resistant. The VFD symmetrical XL can be used in indoor or outdoor applications and is rated for direct burial. The aluminum foil shield makes the VFD symmetrical XL 100% shielded from excessive interference. VFD symmetrical XL is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. Construction: Conductor: annealed copper strands acc. to ASTM B-3 or ASTM B-33 and B-172 or B-174. Also available with bare or tinned copper strands Insulation: special formulated PVC/Nylon Color code: black conductors with three green-yellow earth wires Stranding: in layers Screen: aluminum/polyester shield with a tinned copper drain wire Jacket material: Jacket color: Technical data: Voltage: c(UL)us: 600 V Testing voltage U: conductor/conductor 7500 V conductor/screen 3000 V Temperature: static: c(UL)us: up to +90°C -25°C Burning characteristics: Oil resistant: c(UL)us Type CIC FT4 yes Sunlight resistance: yes Exposed Runs: yes special sunlight and oil resistant PVC with a high strength ripcord under the jacket Direct Burial: yes Drain Wire: yes black Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: item no. ® 08650803 ® 08650603 ® 08650403 ® 08650203 ® 08650103 ® 08651003 ® 08652003 ® 08653003 ® 08654003 ® 08652503 ® 08653103 ® 08653503 ® 08654103 ä Interconnection of variable frequency drive control device to variable frequency motors ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä three green-yellow earth wires and a tinned copper drain wire for optimal performance AWG MCM 8 6 4 2 1 1/0 2/0 3/0 4/0 250 300 350 400 / / / / / / / / / / / / / 3c 3c 3c 3c 3c 3c 3c 3c 3c 3c 3c 3c 3c earth wire n x AWG 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 3x 14 12 12 10 8 8 8 6 6 6 4 4 4 nominal outer-ø mm inch 0.700 0.785 0.975 1.105 1.235 1.315 1.420 1.530 1.760 1.915 2.010 2.130 1.195 17.8 19.9 24.8 28.1 31.4 33.4 26.1 28.9 44.7 48.6 51.1 54.1 30.4 Min. bending cable radius weight ≈ lbs/mft inch 4.2 4.7 5.9 6.6 7.4 7.9 8.5 9.2 10.6 11.5 12.1 12.8 7.2 401 554 809 1147 1471 1719 2032 2521 3139 3596 4296 4873 5347 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com E 25 WTTC TRAY CABLES approval VFD Dual TR Type MTW and WTTC A 79 l NFPdustria n ry for Iachine M Variable frequency drive double insulated tray cable and machine-tool cable C FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C Marking for VFD Dual TR 08620404: A BRÖCKSKES · D-VIERSEN · VFD Dual TR 4 AWG/4c 08620404 THHN (UL) Type TC-ER 90°C 600V, Oil I, Sunlight Resistant, Direct Burial, FT4 (UL) WTTC 90°C 1000V (UL) MTW 4 AWG/4c 600V AWM Style 21179 1000V c(UL) Type CIC SHIELDED 4 AWG/4c 90°C dry 600V FT1, FT2, FT4 CSA AWM I/II A/B 90°C 1000V FT1 FT2 C VFD Dual TR is a flexible shielded motor supply cable designed for automated servo systems. Also machine-tool cable for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). This cable can be used without conduit (exposed runs). Its unique flame retardant jacket makes the VFD Dual TR rated for 600V suitable for tray cable application and also as Control and Instrumentation Cable, UL AWM recognized and CSA approved for 1000 Volt. The VFD Dual TR is double insulated, has an inner PVC jacket as well as an outer PVC jacket and both a foil and a braid shield which helps with problems related to voltage spikes, harmonics, and power distortions frequently associated with variable frequency drives. The VFD Dual TR can be used to connect alternating current variable frequency drives to alternating current variable frequency motors and is approved for up to 50’ of open wiring to make installations less cumbersome. This motor supply cable is also suitable for installation in wet or dry locations and is UV resistant. The VFD Dual TR can be used in indoor or outdoor applications and is rated for direct burial. The combination of the braid and foil shield makes the VFD Dual TR 100% shielded from excessive interference. VFD Dual TR is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). Wind turbine power and control cable is intended to be installed in cable trays or raceways within a wind turbine generator. MTW listed cables can be used in NFPA 79 Machine areas. Technical data: Construction: E 26 Conductor: tinned copper strands acc. to DIN VDE 0295 class 5 + IEC 60228 class 5 + HD 383 class 5 from 18 AWG - 14 AWG, from 10 AWG - 2 AWG class k in acc. to ASTM B 172 conductor/conductor 7500 V conductor/screen 3000 V 12 x O.D. static: UL-AWM: up to +105°C -25°C special formulated PVC, color black Burning characteristics: Oil resistant: (UL) / c(UL) FT4, c(UL) / CSA-AWM FT1, FT2 yes double shield, alu foil and tinned copper braiding Sunlight resistance: yes Exposed Runs: yes Direct Burial: yes Machinery Area: yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Color code: black conductors with consecutive white numbers and green-yellow earth wire Stranding: in layers Inner jacket: Screen : Jacket material: special sunlight and oil resistant PVC Jacket color: black Outstanding features: ä Interconnection of variable frequency drive control device to variable frequency motors ä NFPA 79 for Industrial Machinery ä New improved with WTTC ä WTTC: UL Subject 2277 ä TC: UL Standard 1277 ä (UL)/(cUL) listed AWG nominal outer-ø mm inch 18/4c 16/4c 14/4c 12/4c 10/4c 8/4c 6/4c 4/4c 2/4c Testing voltage U: Temperature: special formulated PVC/Nylon ® 08621804 ® 08621604 ® 08621404 ® 08621204 ® 08621004 ® 08620804 ® 08620604 ® 08620404 ® 08620204 (UL) / c(UL): 600 V UL-AWM/CSA-AWM: 1000 V (UL) WTTC: 1000 V Min. bending radius: Insulation: item no. Voltage: 0.390 0.417 0.461 0.508 0.677 0.874 1.035 1.213 1.382 9.9 10.6 11.7 12.9 17.2 22.2 26.3 30.8 35.1 (UL) / c(UL) / CSA-AWM: up to +90°C cable weight ≈ lbs/mft 95 114 155 196 330 519 731 1027 1408 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES A 79 l NFPdustria n ry for Iachine M TR 249 Type TC and STOOW UV and oil resistant 90°C flexible tray cable - flexible Cord C 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C Marking for TR 249 08491637: A BRÖCKSKES · D-VIERSEN · TR 249 16 AWG/37c 08491637 TFFN (UL) Type TC-ER 90°C 600V, Oil Resistant I, Sunlight Resistant, Direct Burial, FT4 (UL) STOOW 90°C 600V Oil Resistant I AWM Style 21179 600V c(UL) Type CIC 90°C dry 600V FT1 FT2 FT4 C TR 249 is a multi-conductor, 600 V, 90°C, UL recognized, UV and oil resistant flexible tray cable. Also flexible cord for use as specified in the National Electrical Code (NFPA 70) and in the National Fire Protection Association Electrical Standard for Industrial Machinery (NFPA 79). Flexible cords shall be used for connection of portable lamps, portable and mobile signs or appliances, wiring of cranes and hoists. Our specially designed PVC jacket passes the stringent requirements of the VDE test 0281 part 1 and HD 21.1 oil test providing the best oil resistance available for a PVC jacket. TR 249 tray cables are designed for use in all electrical equipment in dry, damp and wet conditions. Recommended applications are machine tools, control systems, assembly lines, CNC machining centers, grinding machines, bottling equipment, data processing equipment and connections between control panels and machines. TR 249 is permitted to be used in hazardous (classified) locations class I, Division 2 per NEC Article 501.4 (B), UL Type TC is in acc. to UL standard 1277 and NEC Article 336 (392, 501). The STOOW listed cable could be used in NFPA 79 Machinery Area. Construction: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Insulation: special formulated PVC Color code: acc. to color code US 2 see page N/23 Stranding: in layers Jacket material: special sunlight and oil resisistant PVC Jacket color: black Voltage: Testing voltage: (UL) / c(UL): 600 V 3000 V Min. bending radius fixed installation: free movement: < 12 mm = 3 x O.D. > 12 mm = 4 x O.D. < 12 mm = 5 x O.D. > 12 mm = 6 x O.D. Radiation resistance: 8 x 107 cJ/kg Temperature: UL-AWM: up to +105°C Burning characteristics: Oil resistance I: (UL) FT4 and c(UL) FT1, FT2, FT4 yes Sunlight resistance: yes Flexible cable for cable tray use even where sunlight resistance is required Exposed Runs: yes Direct Burial: yes Machinery Area: yes ä NFPA 79 for Industrial Machinery ä (UL)/(cUL) listed Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: ä item no. Technical data: no. of conductors incl. ground nominal outer-ø mm inch (UL) / c(UL): up to +90°C cable weight ≈ lbs/mft ® 18 AWG 08491806 08491807 08491808 6 7 8 0.512 0.512 0.575 13.0 13.0 14.6 155 175 202 ® 16 AWG 08491603 3 0.394 10.0 97 ® 12 AWG 08491203 08491204 3 4 0.622 0.670 15.8 17.0 228 272 E-mail: info@sabcable.com Web site: www.sabcable.com E 27 TRAY CABLES D 331 PLTC Type PLTC UV resistant 90°C Power Limited Circuit Cable C 331 PLTC 12 AWG/24c (UL) Type PLTC 90°C 300V C Marking for D 331 PLTC 33311224: A BRÖCKSKES · D-VIERSEN · D 331 PLTC 12 AWG/24c (UL) Type PLTC 90°C 300V C D 331 PLTC is a lead-free low voltage control and signal cable for industrial applications. This UL listed unshielded, multiconductor cable can be used in measuring and process control equipment. D 331 PLTC is also permitted to be used in hazardous (classified) locations class I, Division 2 per NEC article 501 (B). Construction: E 28 Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Insulation: special formulated PVC Color code: one white conductor with number 1; black conductors with consecutive white numbers Stranding: in layers Jacket material: special sunlight resistant PVC Jacket color: black Technical data: Voltage: Testing voltage: 300 V 1500 V Min. bending radius fixed installation: free movement: 7,5 x O.D. 7,5 x O.D. Temperature (UL): up to +90°C Burning characteristics: Sunlight resistance: (UL) FT4 yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: item no. ä Flexible cable for cable tray use even where sunlight resistance is required ä (UL) listed no. of conductors incl. ground ® 20 AWG 33312002 33312003 33312004 33312005 33312006 33312012 33312018 2 3 4 5 6 12 18 nominal outer-ø mm inch 0.205 0.213 0.228 0.248 0.268 0.346 0.425 5.2 5.4 5.8 6.3 6.8 8.8 10.8 cable weight ≈ lbs/mft 24 30 36 41 50 80 120 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com TRAY CABLES s D 331 PLTC Type PLTC C UV resistant 75°C halogen-free Power Limited Circuit Cable D 331 PLTC 12 AWG/24c (UL) Type PLTC 75°C 300V Marking for S D 331 PLTC 83311224: A BRÖCKSKES · D-VIERSEN · T D 331 PLTC 12 AWG/24c (UL) Type PLTC 75°C 300V C S D 331 PLTC is a halogen-free, lead-free low voltage control and signal cable for industrial applications. This UL listed unshielded, multiconductor cable can be used in measuring and process control equipment. S D 331 PLTC is also permitted to be used in hazardous (classified) locations class I, Division 2 per NEC article 501 (B). Construction: Conductor: bare copper strands acc. to IEC 60228 class 5 and UL standard 758 table 5.1 + UL 1581 table 20.1 Insulation: s 231 Color code: one white conductor with number 1; black conductors with consecutive white numbers Stranding: in layers Jacket material: s 235 Jacket color: black Technical data: Voltage: Testing voltage: 300 V 1500 V Min. bending radius fixed installation: free movement: 7,5 x O.D. 7,5 x O.D. Temperature (UL): up to +75°C Zero halogen: acc. to DIN VDE 0472 part 815 and IEC 60754-1 Burning characteristics: Sunlight resistance: (UL) FT4 yes Absence of harmful substances: acc. to RoHS directive of the European Union see page N/25 Outstanding features: item no. ä Flexible cable for cable tray use even where sunlight resistance is required ä (UL) listed no. of conductors incl. ground ® 20 AWG 83312002 83312003 83312004 83312005 83312006 83312012 83312018 2 3 4 5 6 12 18 nominal outer-ø mm inch 0.205 0.213 0.228 0.248 0.268 0.346 0.425 5.2 5.4 5.8 6.3 6.8 8.8 10.8 cable weight ≈ lbs/mft 29 34 40 47 54 91 136 Other dimensions and colors are possible on request. E-mail: info@sabcable.com Web site: www.sabcable.com E 29