Test Report issued under the responsibility of: TEST REPORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Number. ..............................: 17706513 001 Date of issue ...................................: See cover page Total number of pages ...................: See cover page Applicant’s name ............................: Hisense Electric Co., Ltd. Address ...........................................: No. 218, Qianwangang Road, Qingdao Economic & Technology Development Zone, Shandong 266555, P.R. China Test specification: Standard ..........................................: EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 +A12:2011 Test procedure................................: COC-LVD Non-standard test method .............: N/A Test Report Form No. .....................: IEC60065K Test Report Form(s) Originator.....: Intertek Semko AB Master TRF ......................................: Dated 2010-10 Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .....................: LCD TV Trade Mark ......................................: Hisense Manufacturer ...................................: Same as applicant Model/Type reference ....................: LTDN40K321UWTSEU, UB40EC591UWTSEU Ratings ............................................: AC 220-240V, 50Hz, 90W, Class II Page 3 of 21 Report No.: 17706513 001 Testing procedure and testing location: Testing Laboratory: Testing location/ address ........................ : TÜV Rheinland / CCIC (Qingdao) Co., Ltd. 6F, No.2 Bldg., No.175 Zhuzhou Road, Qingdao 266101, P.R. China Associated Laboratory: Testing location/ address ........................ : Tested by (name + signature) ....... : See cover page Approved by (name + signature) .. : See cover page Testing procedure: TMP Testing location/ address ........................ : Tested by (name + signature) ....... : Approved by (name + signature) .. : Testing procedure: WMT Testing location/ address ........................ : Tested by (name + signature) ....... : Witnessed by (name + signature) . : Approved by (name + signature) .. : Testing procedure: SMT Testing location/ address ........................ : Tested by (name + signature) ....... : Approved by (name + signature) .. : Supervised by (name + signature) : Testing procedure: RMT Testing location/ address ........................ : Tested by (name + signature) ....... : Approved by (name + signature) .. : Supervised by (name + signature) : Page 4 of 21 Report No.: 17706513 001 List of Attachments (including a total number of pages in each attachment): - ATTACHMENT 1 - National Differences (16 pages) - ATTACHMENT 2 – Photo documentation (6 pages) - ATTACHMENT 3 - Test report No. 17706468 001, 52 pages with attachments of National Differences, 17 pages and Photo Documentation, 10 pages, issued on 2015-05-29 by TÜV Rheinland / CCIC (Qingdao) Co., Ltd. Note: Total number of pages in each attachment is indicated in individual attachment. Summary of testing: 1) According to the “General product information”, relevant tests were tested on LTDN40K321UWTSEU. The appliance complied with the requirements after the evaluation. 2) EMF was evaluated in test report No. 17706517 001. Tests performed (name of test and test clause): Testing location: Marking and instructions– Clause 5 Heating under normal operation conditions – Clause 7.1 Terminals – Clause 9.1.4 Resistance to external forces – Clause 9.1.7 Insulation resistance & Dielectric strength – Clause 10.3 Fault conditions – Clause 11.2 Bump Test – Clause 12.1.1 Impact Test – Clause 12.1.3 Stress Relief Test – Clause 12.1.5 Fixing of actuating elements – Clause 12.2 Remark: Relevant tests were tested on the sample registered No. A000196174-001. The sample is an engineering sample without serial number. Unless otherwise indicated, all tests were performed at the location stated in “Testing procedure and testing location”. Table 14 completely listed for reference. Summary of compliance with National Differences List of countries addressed: EU Group Differences, EU Special National Conditions. Refer to the ATTACHMENT 1 of this test report for details. Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. <LTDN40K321UWTSEU> Page 5 of 21 <UB40EC591UWTSEU> Report No.: 17706513 001 Page 6 of 21 Report No.: 17706513 001 Test item particulars .................................................. : Classification of installation and use ...................... : Class II Supply Connection .................................................... : Detachable supply cord Possible test case verdicts: - test case does not apply to the test object .......... : N/A (Not Applicable) - test object does meet the requirement ................. : P (Pass) - test object does not meet the requirement .......... : F (Fail) Testing: Date of receipt of test item ........................................ : 05 May, 2015 Date (s) of performance of tests .............................. : 08 May, 2015 to 29 May, 2015 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided ................................................................ : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies) .............................. : Hisense Electric Co., Ltd. No. 218, Qianwangang Road, Qingdao Economic & Technology, Development Zone, Shandong 266555, P.R. China General product information: The EUTs are ordinary LCD TVs with LED backlight, which are normally for home use within the scope of IEC/EN 60065. As declared by client, LTDN40K321UWTSEU and UB40EC591UWTSEU are identical with the the approved type LTDN40K321UWAU in original CB test report No. 17706468 001 issued by TÜV Rheinland / CCIC (Qingdao) Co., Ltd. except that - Mainboard changed (Main IC not changed) - Rated input changed into 220-240V 50Hz 90W from 100-240V 50/60Hz 95W - Addpower switch and primary wire - One AC connetor added on power supply board to connect power switch - Material for enclosure changed - Alternative AC inlet sources added, which has the same rating and specification with the original one. According to above changes, the consturction was checked and relevant tests listed in page 4 were performed. Page 7 of 21 Report No.: 17706513 001 IEC 60065 Clause Requirement + Test 5 Marking and instructions 5.1 5.2 Result - Remark Verdict P Comprehensible and easily discernible Markings are permanent, comprehensible and easily discernible on the apparatus. Permanent durability against water and petroleum spirit The same material and printing means for the marking label. No additional test is necessary. P N/A a) Identification, maker .............................................: See marking label P b) Model number or type reference ..........................: See marking label P c) Class II symbol if applicable ................................: Used according to IEC 604175172. P d) Nature of supply ....................................................: Used according to IEC 604175032. P e) Rated supply voltage ...........................................: See marking labels P f) Mains frequency if safety dependant ...................: See marking labels P g) Rated current or power consumption for apparatus supplied by supply apparatus for general use ............................................................................: N/A Measured current or power consumption ................: N/A Deviation % (max 10%) ...........................................: N/A h) Rated current or power consumption for apparat- For use with single phase us intended for connection to an a.c. mains supply .: mains supply. P Measured current or power consumption ................: See below P See appended table. Measured current or power consumption for Television set ............................................................: P Deviation % (max 10%) ...........................................: Not more than 10% P a) Earth terminal Class II apparatus N/A b) Hazardous live terminals No such terminals N/A c) Markings on supply output terminals No such terminals N/A a) Use of triangle with exclamation mark The symbol was marked on circuit diagram for safety related components. b) marking on loudspeaker grille, IEC 60417-5036 No such construction. 5.4 Instructions for use Instruction manual for safety was available and English version was checked. P 5.4.1 a) Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc. Provided in user manual. P b) Hazardous live terminals, instructions for wiring No such terminals. N/A c) Instructions for replacing lithium battery No such battery used. N/A 5.3 P N/A Page 8 of 21 Report No.: 17706513 001 IEC 60065 Clause Requirement + Test Result - Remark d) Class I earth connection warning Class II apparatus. e) Instructions for multimedia system connection Provided in user manual. Provided in user manual. h) Warning: protective film on CRT face 5.4.2 a-b) Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings N/A P N/A f) Special stability warning for attachment of the apparatus to the floor/wall g) Warning: battery exposure to heat Verdict P N/A MAINS plug on supply cord used as disconnect device. P c) Instructions for permanently connected equipment N/A Marking, signal lamps or similar for completely disconnection from the mains N/A 7 Heating under normal operating conditions P 7.1 Temperature rises not exceeding specified values; fuse links and other protective devices defeated 7.1.1 Temperature rise of accessible parts N/A 7.1.2 Temperature rise of parts providing electrical insulation N/A 7.1.3 Temperature rise of parts acting as a support or as a mechanical barrier N/A 7.1.4 Temperature rise of windings N/A 7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 N/A 9 Electric shock hazard under normal operating conditions P 9.1.4 Terminal devices tested with 1 mm x 20 mm test pin Applied to antenna and all (10 N); test probe D of IEC 61032 input/output signal connectors. P 9.1.7 P Terminal devices tested with 1 mm x 100 mm straight wire (1 N); test probe D of IEC 61032 See above P Resistance to external forces See below P a) Test probe 11 of IEC 61032 for 10 s (50 N) Compliance is checked by inspection. P b) Test hook of fig. 4 for 10 s (20 N) Compliance is checked by inspection. P c) 30 mm diameter test tool for 5 s (100 or 250 N) 10 Lower input power consumption than previously approved type. No additional test is necessary. (see appended table) Insulation requirements N/A P Page 9 of 21 Report No.: 17706513 001 IEC 60065 Clause Requirement + Test Result - Remark 10.3 Insulation resistance and dielectric strength between (see appended table) mains terminals 11 Fault conditions 11.2 Heating under fault condition P N/A Insulation Resistance and dielectric strength across BASIC or SUPPLEMENTARY insulation (Class I) Insulation resistance and dielectric strength across REINFORCED insulation (Class II) Verdict (see appended table) P P Lower input power consumption than previously approved type. No additional test is necessary. P Flames extinguish within 10 seconds N/A No hazard from softening solder N/A P Soldered terminations not used as protective mechanism 11.2.1 Measurement of temperature rises See above P 11.2.2 Temperature rise of accessible parts See above P 11.2.3 Temperature rise of parts, other than windings and printed boards, providing electrical insulation See above P 11.2.4 Temperature rise of parts acting as a support or mechanical barrier See above P 11.2.5 Temperature rise of windings See above P 11.2.6 Temperature rise of printed boards shall not exceed the limits of table 3 by max. 100 K for max. 5 min N/A Printed circuit boards (PCB) classified as V-0 according to 60695-11-10 or Clause G.1 may exceed the limit in table 3 in case a) and b): N/A a) Temperature rise of printed circuit boards exceeding the limits of table 3 by not more than 100 K for an area not greater than 2 cm² ............... : N/A b) Temperature rise of printed circuit boards exceeding the limits of table 3 up to 300 K for an area not greater than 2 cm² for a maximum of 5 min N/A Meets all the special conditions if conductors on printed circuit boards are interrupted N/A Class I protective earthing maintained N/A 11.2.7 Temperature rise of parts not subject to the limits of 11.2.1 to 11.2.6 shall not exceed the limits in table 3, item e), "Fault conditions". P 12 Mechanical strength P Page 10 of 21 Report No.: 17706513 001 IEC 60065 Clause Requirement + Test Result - Remark Verdict 12.1.1 Bump test where mass >7 kg The mass of the EUT is more than 7.0kg. P 12.1.3 Impact hammer test No hazards. P Steel ball test 2J is carried to other enclosure parts. No hazardous live parts become accessible. P 12.1.5 Thermoplastic enclosures stress relief test A sample consisting of the complete apparatus is subjected in a circulating air oven to a temperature 70°C, after the test, no hazardous live parts can be accessible. P 12.2 Fixing of knobs, push buttons, keys and levers P 14 Components P 14.6 Switches (see appended table) P 14.6.1 a) Separate testing to IEC 61058-1 including: - 10 000 operations - Normal pollution suitability - Make and break speed independent of speed of actuation V-0 compliance with annex G, G.1.1 An approved switch used and comply the relative standard P 14.6.1 b) Tested in the apparatus: N/A Switch controlling > 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and V-0 in annex G, G.1.1 N/A Switch controlling > 0.2A with open contact voltage < 35 V (peak)/24 V dc complying with 14.6.3 and V0 in annex G, G.1.1 N/A Switch controlling < 0.2A with open contact voltage > 35 V (peak)/24 V dc complying with 14.6.4 and V-0 in annex G, G.1.1 N/A 14.6.2 Switch tested to 14.6.1 b) constructed to IEC 610581 subclause 13.1 and has making/breaking action independent of speed of actuation N/A 14.6.3 Switch tested to 14.6.1 b) compliant with IEC 610581 subclause 16.2.2 d) and m) not attaining excessive temperatures in use N/A 14.6.4 Switch tested to 14.6.1 b) has adequate dielectric strength N/A 14.6.5 Mains switch controlling mains socket outlets additional tests to IEC 61058-1 N/A Socket outlet current marking correct N/A Page 11 of 21 7.1 Report No.: 17706513 001 TABLE: temperature rise measurements: P Power consumption in the OFF/Stand-by mode of the functional switch (W) ......................................... : Cond. Un (V) Hz In (A) 0W/ 0.46W max Pn (W) Uout (V) Pout (W) Operating Condition / Status Max. normal load with 1/8 non-clipped max. audio output power 1. 240 50 0.42 86.6 -- -- ATV mode 2. 240 50 0.42 86.5 -- -- AV mode 3. 240 50 0.42 86.6 -- -- Component mode 4. 240 50 0.42 86.5 -- -- HDMI mode 5. 198 50 0.47 86.2 -- -- ATV mode 6. 220 50 0.44 86.0 -- -- ATV mode 7. 240 50 0.42 86.6 -- -- ATV mode 8. 264 50 0.43 86.1 -- -- ATV mode Notes: The input power was lower than test results for approved type (88.9W at 100V input and 88.7W at 240V input) in original test report 17706468 001. No additional tests necessary 10.3 TABLE: insulation resistance measurements P R (MΩ) Required R (MΩ) Unit: Primary circuits (L/N) to back cover and power switch (RI) >100 4 Unit: Primary circuits (L/N) to signal connectors (RI) >100 4 Primary wire (RI) >100 4 Insulation resistance R between: Notes: -10.3 TABLE: electric strength measurements P Test voltage applied between: Test voltage (V) Breakdown Unit: Primary circuits (L/N) to back cover and power switch (RI) 4240 (peak) No Unit: Primary circuits (L/N) to signal connectors (RI) 4240 (peak) No Primary wire (RI) 4240 (peak) No Notes: -11.2 TABLE: summary of fault condition tests P Voltage (V) 0,9 or 1,1 times rated voltage ............. : See below — Frequency (Hz) ........................................................ : 60 — o Ambient temperature ( C) ....................................... : No. 1. Component One speaker Fault s-c o 22.0 C — dT (K) / Component Other results (include description and test duration) -- Input voltage: 264V Input: 81.8W; Both speakers did not work. The other parts worked as normal. No hazards. Duration: 10 minutes Page 12 of 21 No. Component Fault 2. USB output (mainboard) s-c 3. USB output (mainboard) o-l Report No.: 17706513 001 dT (K) / Component Other results (include description and test duration) -- Input voltage: 264V Input: 84.4W The EUT worked as normal except for the USB port. Duration: 10 minutes Input: 198V Duration: 120 minutes Input: 108.0W Normal operation until overload to 4.0A. No breakdown, no hazards. — Winding temperature rise measurements o Ambient temperature t1 ( C) .................................. : — o — Ambient temperature t2 ( C) .................................. : Supplementary information: 1) In fault column, where s-c=short circuit, o-l=overload; 2) The input power of USB overload is lower than the test results in previous test report 17706468 001. No additional heating test was necessary on new model with the same construction. 14 TABLE: list of critical components and materials P Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of 1) conformity Power supply board Hisense Electric Co., Ltd. HLL-4855WP Input: AC 100240V, 50/60Hz, 3A Max; output: DC12V, 3A; DC16V, 1.5A; DC200V 400mA. IEC/EN 60065 Tested with equipment -PCB Changzhou Aohong Electronics Co., Ltd AOH-2 V-0, 1.5mm Min. UL 94 UL 796 Thick, 130C. -(Alternative) Interchangeable Interchangeable V-0, 1.5mm Min. UL 94 UL 796 Thick, 120C min. -AC inlet (XP802) Zhang Jiagang SA-2S Huajie Electronic Co., Ltd 250V AC, 2.5A 70C IEC/EN 60320-1 TUV R 50018670 -(Alternative) Zhang Jiagang SA-2S C, SA-2S 250V AC, 2.5A Huajie Electronic D, SA-2S D1, 70C Co., Ltd SA-2S E, SA-2S C-2 IEC/EN 60320-1 TUV R 50187984 -(Alternative) Zhang Jiagang SA-2S H, SA-2S 250V AC, 2.5A Huajie Electronic L, SA-2S J, SA- 70C Co., Ltd 2S K, SA-2S M, SA-2S N IEC/EN 60320-1 TUV R 50256890 UL E303981 UL Page 13 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard -(Alternative) Zhang Jiagang Huajie Electronic Co., Ltd SA-2S-127 SA-2S-129 SA-2S-165 250V AC, 2.5A 70C IEC/EN 60320-1 TUV R 50304415 -(Alternative) Zhe Jiang Bei Er ST-A03 series Jia Electronic Co., Ltd. 250V AC, 2.5A 70C IEC/EN 60320-1 ENEC ENEC00636 VDE 40014833 -(Alternative) TECX-UNIONS ELECTRONIC CO., LTD SO-222 250V AC, 2.5A 70°C IEC/EN 60320-1 VDE 40020337 -Fuse (F801) Littelfuse Inc. 382 T6.3AL, AC 250V IEC/EN 60127-1 VDE 40018250 IEC/EN 60127-3 -(Alternative) XC Electronics (Shenzhen) Corp. Ltd. 5TR T6.3AL, AC 250V IEC/EN 60127-1 VDE 40036800 IEC/EN 60127-3 -(Alternative) Conquer Electronics Co., Ltd. MET T6.3AL, AC 250V IEC/EN 60127-1 VDE 40017155 IEC/EN 60127-3 -(Alternative) Dongguan Walter Electric Co., Ltd 2000 T6.3AL, AC 250V IEC/EN 60127-1 VDE 40018787 IEC/EN 60127-3 -VDR (RV801) Thinking Electronic lndustrial Co., Ltd. TVR10621-V 620V, fulfil IEC 60950-1 Annex Q IEC 61051-1 IEC 61051-2 VDE 005944 -(Alternative) Thinking Electronic lndustrial Co., Ltd. TVR10621-D 620V, fulfil IEC 60950-1 Annex Q IEC 61051-1 IEC 61051-2 VDE 40021243 -(Alternative) EPCOS OHG S10KV621E2K1 620V, fulfil IEC 60950-1 Annex Q IEC 61051-1 IEC 61051-2 VDE 40027582 -Filter (L801, L802) Jiangsu Lettall Electronics Co., Ltd. LCL-3505-HP 130C IEC/EN 60065 Tested with equipment -(Alternative) Haining Lianfeng LCL-020-P Dongjin Electronic Co., Ltd. 130C IEC/EN 60065 Tested with equipment -(Alternative) Qingdao Jingshi Electronic CO.,LTD LCL-H1806 130C IEC/EN 60065 Tested with equipment -(Alternative) Dezhou Sanhe Electric Co., Ltd. LCL-35-012 130C IEC/EN 60065 Tested with equipment -(Alternative) Weihai Dongxing LCH-20016-01 Electronics Co., Ltd. 130C IEC/EN 60065 Tested with equipment -(Alternative) Linyi Zhongrui Electronics Co., Ltd. 130C IEC/EN 60065 Tested with equipment ZRI-15015-03 Mark(s) of 1) conformity Page 14 of 21 Standard Mark(s) of 1) conformity Jiangsu Huaxing LCL-1806D-153 130C Electric Co., Ltd IEC/EN 60065 Tested with equipment -- bobbin Changchun T375J Plastics Co., Ltd. Phenolic, 150C, V-0 UL 94 UL E59481 -- (Alternative) Interchangeable Interchangeable Phenolic, 150C; V-0 UL 94 UL -NTC (RT801) Interchangeable Interchangeable 5Ω at 25C UL 1434 UL -Bleeder Interchangeable resistor (R802, R804, R809, R970, R971, R972) Interchangeable 1MΩ, 1/4W IEC/EN 60065 Tested with equipment -X2 Capacitor ( C813, C846) Xiamen Faratronic Co., Ltd. MKP62 0.47μFmax., IEC/EN 60384AC 275V,110C 14 VDE 40000358 -(Alternative) Xiamen Faratronic Co., Ltd. MKP61 0.47μF max., IEC/EN 60384AC 275V,100C 14 VDE 40007424 -(Alternative) Nanjing Tengen MKP Rongguangda Electronics (Group) Co., Ltd. 0.47μF max., IEC/EN 60384AC 275V, 100C 14 VDE 40028680 -Electrolytic capacitor (C860) Interchangeable Interchangeable 82μF, 450V min., 105C IEC/EN 60065 Tested with equipment -Y1 Capacitor (C803, C804, C809) Anshan Electronic Ceramic Co., Ltd. CT7 C803=C804= 470pF max, C809= 1000pF max., AC250V min., 125C IEC/EN 6038414 VDE 40011817 -(Alternative) TDK Xiamen Co., Ltd. CD C803=C804= 470pF max, C809=1000pF max., AC250V min., 85C IEC/EN 6038414 VDE 124321 -(Alternative) Yinan Don’s Electronic Component Co., Ltd. CT81 C803=C804= 470pF max, C809=1000pF max., AC250V min., 125C IEC/EN 6038414 VDE 135256 -(Alternative) Guangdong F South Hongming Electronic Science and Technology Co., Ltd. C803=C804= 470pF max, C809=1000pF max., AC250V min., 125C IEC/EN 6038414 VDE 40036393 -(Alternative) Murata Manufacturing Co., Ltd. C803=C804= 470pF max, C809=1000pF max., AC250V min., 125C IEC/EN 6038414 VDE 40002831 Object / part No. Manufacturer/ trademark -(Alternative) Type / model KX Technical data Report No.: 17706513 001 Page 15 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of 1) conformity -(Alternative) Kunshan Wansheng Electronics Co., Ltd. CT7 C803=C804= 470pF max., C809=1000pF max., AC250V min., 125C IEC/EN 6038414 VDE 40012143 -Transformer (T831) Jiangsu Lettall Electronic Co., Ltd. BK-10-05HM Class B, refer to IEC/EN 60065 table 14.3.3& IEC 60085 14.3.4 for details Tested with equipment -(Alternative) Haining Lianfeng BCK-70-05HM Dongjin Electronic Co., Ltd. Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Yueqing Jingmi Electron Electronic Co., Ltd. XW40EFD2B21H015 Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Dezhou Sanhe Electric Co., Ltd. SANHE-35-249 Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Weihai Dongxing BCK-EFD-3335 Electronics Co., Ltd. Same as above IEC/EN 60065 IEC 60085 Tested with equipment -- Windings Interchangeable UL 1446 UL -- Bobbin Sumitomo PM-9820 Bakelite Co., Ltd. Phenolic, 150C; V-0 UL 94 UL E41429 (Alternative) Chang Chun T375J Plastics Co., Ltd. Phenolic, 150C; V-0 UL 94 UL E59481 (Alternative) Interchangeable Interchangeable Phenolic, 150C; V-0 UL 94 UL --Insulation tape Yahua Pressure Sensitive Glue Co., Ltd. CT 130C, flame retardant UL 510 UL E165111 --Margin tape Yahua Pressure Sensitive Glue Co., Ltd. WF 130C, flame retardant UL 510 UL E165111 -Transformer (T901) Haining Lianfeng BCK-70-39FB Dongjin Electronic Co., Ltd. -(Alternative) Jiangsu Lettall Electronics Co., Ltd. -(Alternative) Interchangeable 130C Class B, refer to IEC/EN 60065 table 14.3.3& IEC 60085 14.3.4 for details Tested with equipment BK-20-12FB Same as above IEC/EN 60065 IEC 60085 Tested with equipment Yueqing Jingmi Electron Electronic Co., Ltd. XW40EFD2A38H012 Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Dezhou Sanhe Electric Co., Ltd. SANHE-35-273 Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Weihai Dongxing BCK-EFD-3542 Electronics Co., Ltd Same as above IEC/EN 60065 IEC 60085 Tested with equipment Page 16 of 21 Object / part No. Manufacturer/ trademark Type / model -- Windings Interchangeable -- Cover E I Dupont De Nemours & Co Inc. -- Bobbin Standard Mark(s) of 1) conformity Interchangeable 130C UL 1446 UL FR50(+)(f1) V-0, PA66, 0.5 mm thick min. UL 94 UL E41938 PM9820 Sumitomo Bakelite Co., Ltd. Phenolic, 150C; 0.8 mm thick min. V-0 UL 94 UL E41429 (Alternative) T375J Chang Chun Plastics Co., Ltd. Phenolic, 150C; 0.8 mm thick min. V-0 UL 94 UL E59481 (Alternative) Interchangeable Interchangeable Phenolic, 150C; 0.8 mm thick min. V-0 UL 94 UL --Margin tape Yahua Pressure Sensitive Glue Co., Ltd. WF 130C, flame retardant UL 510 UL E165111 --(Alternative) Interchangeable Interchangeable 130C, flame retardant UL 510 UL --Insulation tape Yahua Pressure Sensitive Glue Co., Ltd. CT 130C, flame retardant, UL 510 UL E165111 --(Alternative) Suzhou Mailaduona Electric Material Co., Ltd JY312 130C, flame retardant, UL 510 UL E188295 --(Alternative) Interchangeable Interchangeable 130C, flame retardant, UL 510 UL -Transformer (T902) Weihai Dongxing BCK-25-1605 Electronics Co., Ltd. Class B, refer to IEC/EN 60065 table 14.3.3& IEC 60085 14.3.4 for details Tested with equipment -(Alternative) Yueqing Jingmi Electron Electronic Co., Ltd. XW2025EPCB05H003 Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Jiangsu Lettall Electronics Co., Ltd. BK-10-05YG Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Haining Lianfeng BCK-20-1605 Dongjin Electronic Co., Ltd. Same as above IEC/EN 60065 IEC 60085 Tested with equipment -(Alternative) Dezhou Sanhe Electric Co. Ltd. SANHE-19-065 Same as above IEC/EN 60065 IEC 60085 Tested with equipment --Pri. Windings Interchangeable Interchangeable 130C UL 1446 UL TEX-E UL 2353 UL E206440 IEC/EN 60950-1 VDE 006735 IEC/EN 60065 --Sec. windings FURUKAWA ELECTRIC CO LTD Technical data Report No.: 17706513 001 130C, triple insulation wire Page 17 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard -(Alternative) Shanghai Lucy Trade Co., Ltd. TIW-B 130C, triple insulation wire UL 2353 UL E305883 IEC/EN 60950-1 VDE 40023686 IEC/EN 60065 --Bobbin Interchangeable Interchangeable Phenolic, 150C; V-0 UL 94 UL --Insulating tape Interchangeable Interchangeable 130C, flame retardant UL 510 UL --Tubing Interchangeable Interchangeable 200C, 600V, VW-1 UL 224 UL -Photocoupler (N881, N891) Everlight Electronics Co., Ltd. EL817 Int.=6.0mm min., Ext.=7.7mm min., dti. =0.5mm min., 110C IEC/EN 60065 DEMKO DIEC/EN 60950-1 00764-A1 -(Alternative) VISHAY Semiconductour GmBH VO617A Int.=5.2mm min., Ext.=7.8mm min., dti. =0.6mm min., 100C IEC/EN 60065 FIMKO NCS/FI IEC/EN 60950-1 26764 A1 -(Alternative) Lite-On Technology Corporation LTV-817 Int.=5.2mm min., Ext.=7.7mm min., dti.=0.6mm min., 110C IEC/EN 60065 Intertek IEC/EN 60950-1 1312430 -(Alternative) AUK Corp. PC-17K1 Int.=8.0mm, Ext.=8.0mm, dti. ≥0.4mm, 100C IEC/EN 60065 VDE 40010361 IEC/EN 60950-1 Semko 1118939 Main IC Media Tek Inc. MT5657 -- -- PCB Interchangeable Interchangeable V-0, 1.6mm min. UL 94 UL 796 thick, 120C min. Hisense Electric Co., Ltd. HD396DU-B01 Mark(s) of 1) conformity Mainboard -- UL Others LCD Panel IEC/EN 60065 39.6 inch TFT LCD with LED backlight. Total power consumption for LED Backlight is 46.2W Tested with equipment Page 18 of 21 Type / model Technical data Report No.: 17706513 001 Standard Object / part No. Manufacturer/ trademark Main switch Zhangjiagang HF-606(TV)-P Huafeng HF-606(TV)-S Electronic Connector & Component Co., Ltd. Rocker switch, IEC/EN 61058-1 VDE 40008136 TV-5, 8A/128A TUV AC 250V, R50120515 T85/55, 10E3, Level 3 (Alternative) Alps Electric Co., Ltd SDDJE Rocker switch, IEC/EN61058-1 10(6)A, AC 250V, 1E4, T55, Level 3 VDE 40026948 (Alternative) Zhangjiagang Huajie Electronic Co., Ltd. PS8 Rocker switch, IEC/EN61058-1 6(4)A, AC 250V, 5E4, T85/55, Level 3 VDE 40027662 TUV R50191561 (Alternative) Zhejiang LECI RS601D Electronics Co., Ltd. 6(4)A, AC 250V, IEC/EN 61058-1 VDE 40017430 1E4, T55, Level TUV 3; 8A/128A, AC R50210040 250V, 1E4, T55. (Alternative) Zhejiang KCD1-104-2 Zhongxun Electronics Co., Ltd 10(6)A or 6/12A IEC/EN 61058-1 TUV AC 250V, 1E4, R50264134 T55 (Alternative) ZheJiang Beierjia Rocker switch, IEC/EN61058-1 12(4)A, AC 250V, 10E3, T55 PS8A-11 Electronics Co., Ltd Mark(s) of 1) conformity VDE 40024550 Primary wire Interchangeable AWM1672 VW-1, 105C, 300V, 20AWG, reinforced insulation UL 758 UL Insulating sheet SE42B Suzhou Omay Optical Materials Co., Ltd. PC, 0.5mm thick, V-0, 80C UL 94 UL E249605 (Alternative) Chengdu KLX FRPCKanglongxin 870B Plastics Co., Ltd. PC, 0.5mm thick, V-0, 80C UL 94 UL E315185 AC connector I-Sheng Electric Wire & Cable Co., Ltd. IS-037 AC 250V, 2.5A IEC/EN 60320-1 VDE 40026164 (Alternative) I-Sheng Electric Wire & Cable Co., Ltd. IS-033 AC 250V, 2.5A IEC/EN 60320-1 VDE 40026860 (Alternative) Taiwan Linetek Electronic Co., Ltd. LS-7H AC 250V, 2.5A IEC/EN 60320-1 VDE 40028570 (Alternative) Shanghai Yusheng Enterprise Development Co., Ltd YS-65 AC 250V, 2.5A IEC/EN 60320-1 VDE 40020913 Page 19 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard (Alternative) Weihai Honglin Electronic Co., Ltd HL-028 2.5A, AC 250V IEC/EN 60320-1 VDE 40039499 (Alternative) Weihai Honglin Electronic Co., Ltd HL-028S 2.5A, AC 250V IEC/EN 60320-1 VDE 40029835 Main Plug Shanghai Yusheng Enterprise Development Co., Ltd. YS-2 250VAC,16A VDE 0620-1 VDE 123226 (Alternative) I-Sheng Electric Wire & Cable Co., Ltd. SP-026A 250VAC,16A VDE0620-1 VDE 40016019 (Alternative) Shenzhen Xiekang Electric Co., Ltd. XK-36 250VAC, 16A VDE 0620-1 VDE 40026243 (Alternative) Interchangeable Interchangeable 250VAC, 16A VDE 0620-1 VDE (Alternative) Shenzhen Xiekang Electric Co., Ltd. XK-01 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 40009009 (Alternative) I-Sheng Electric Wire & Cable Co., Ltd. SP-021A 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 40013649 (Alternative) Shanghai Yusheng Enterprise Development Co., Ltd. YS-3 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 112875 (Alternative) Longkou Jin Sheng Electronics Products Co., Ltd. LFD-215 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 40027592 (Alternative) Zhejiang Yuehua YP205 Telecommunicati on Co., Ltd. 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 40013170 (Alternative) Taiwan Line Tek Electronic Co., Ltd. LP-21 250VAC, 2.5A VDE 0620-101 EN 50075 VDE 40009324 (Alternative) Interchangeable Interchangeable 250VAC, 2.5A VDE 0620-101 EN 50075 VDE or TUV (Alternative) Shenzhen Xiekang Electric Co., Ltd. XK-28 250VAC, 5A BS 1363-1 Intertek ASTA 972 (Alternative) Shanghai Yusheng Enterprise Development Co., Ltd. YS-55 250VAC, 5A BS 1363-1 BSI KM68299 Mark(s) of 1) conformity Page 20 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of 1) conformity (Alternative) Taiwan Line Tek Electronic Co., Ltd. LP-61L 250VAC, 5A BS 1363-1 BSI KM55112 (Alternative) Zhejiang Yuehua YP317 Telecommunicati on Co., Ltd. 250VAC, 5A BS 1363-1 BSI KM512007 (Alternative) Interchangeable Interchangeable 250VAC, 5A BS 1363-1 BSI, Intertek or TUV Power Cord Zhejiang Yuehua H03VVH2-F Telecommunicati H05VVH2-F on Co., Ltd. 2x0.75mm 2 IEC 60227 VDE 0281-5 AS/NZS 60227 VDE 112929 SAA Q06048 (Alternative) Long Kou Jin H03VVH2-F Sheng Electronic Products Co., Ltd. 2x0.75mm 2 IEC 60227 VDE 0281-5 VDE 126716 (Alternative) I-Sheng Electric Wire & Cable Co., Ltd. 2x0.75mm² VDE 0281-5 IEC 60227 VDE 40006070 (Alternative) Mainland Electric H03VVH2-F Wire & Cable Co., Ltd. 2x0.75mm 2 IEC 60227 VDE 0281-5 VDE 40010355 (Alternative) Shenzhen Xiekang Electric Co., Ltd. H03VVH2-F 2x0.75mm 2 IEC 60227 VDE 0281-5 VDE 40029225 (Alternative) Interchangeable H03VVH2-F H05VVH2-F 2x0.75mm 2 IEC 60227 or VDE 0281-5 VDE or equivalent Front Enclosure Cheil Industries Inc Chemicals Div Huizhou Wote Advanced Materials Co Ltd Asia Int’L Enterprise (Hongkong) Co., Ltd Orinko (Hefei) Advanced Plastic Co., Ltd LG Chem(Tianjin) Engineering Plastics Co Ltd Teijin Chemicals Ltd LS-1159(R) V-1, Min. 1.6mm thick. UL 94 UL E115797 2000 V-0, Min. 1.6mm thick. UL 94 UL E310240 A2200FR(#) V-0, Min. 1.6mm thick. UL 94 UL E252275 PC/ABS-551X V-0, Min. 1.6mm thick. UL 94 UL E328304 LUPOY GN5(j)1F(#) V-0, Min. 1.6mm thick. UL 94 UL E302314 RN-7715(#) V-0, Min. 1.6mm thick. UL 94 UL E98529 V-0, Min. 1.8mm thick. UL 94 UL E330547 (Alternative) (Alternative) (Alternative) (Alternative) (Alternative) H03VVH2-F Rear Enclosure Qingdao Guoen PS3001ZScience & 600A(b) Technology Co., Ltd. Page 21 of 21 Report No.: 17706513 001 Object / part No. Manufacturer/ trademark Type / model Technical data Standard Mark(s) of 1) conformity (Alternative) Huizhou Wote Advanced Materials Co., Ltd. 51(x)FR V-0, Min. 1.8mm thick. UL 94 UL E310240 (Alternative) Orinko (Hefei) Advanced Plastic Co Ltd HIPS-2230 V-0, Min. 1.8mm thickness. UL 94 UL E328304 Plastic for stand Asia Int'l Enterprise (Hong Kong) Ltd 60G6F V-0, Min. 2.0mm thick. UL 94 UL E252275 Notes: 1) Provided evidence ensures the agreed level of compliance. 2) Parts in bold are different from the list in original CB test report. The End of this test Report ATTACHMENT 1 Page 1 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60065 EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Audio, video and similar electronic apparatus – Safety requirements Differences according to ............... : EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011 Attachment Form No. ..................... : EU_GD_IEC60065K_II Attachment Originator ................... : Intertek Semko AB Master Attachment ......................... : Date (2011-08) Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN)) Clause Requirement + Test Contents Add the following annexes: Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications (See the CB Bulletin) Annex ZB (nominative) Special national conditions Annex ZC (informative) A-deviations Definition 2.2.Z1 (A11:2008) Add after the definition 2.2.12 the following new definition: PORTABLE SOUND SYSTEM small battery powered audio equipment: whose prime purpose is to listen to recorded or broadcasted sound; and that uses headphones or earphones that can be worn in or on or around the ears; and Result - Remark Verdict P N/A that allows the user to walk around NOTE Examples are mini-disc or CD players, MP3 audio players or similar equipment. 2.2 (A12:2011) In EN 60065:2002/A11:2008 Delete the definition 2.2.Z1 P ATTACHMENT 1 Page 2 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict 3.1 Add the following indent at the end of the list - Exposure to excessive sound pressures from headphones or earphones NOTE A new method of measurement is described in EN 50332-1, Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 1: General method for ”one package equipment”, and in EN 50332-2, Sound system equipment: Headphones and earphones associated with portable audio equipment – Maximum sound pressure level measurement methodology and limit considerations – Part 2: Guidelines to associate sets with headphones coming from different manufacturers. N/A 3.1 (A12:2011) In EN 60065:2002 Delete the addition of indent regarding sound pressure excessive N/A 3.Z1 (A2:2010) After 3.2 add a new clause 3.Z1: To protect against excessive current, shortcircuits and earth faults in MAINS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 11 shall be included as parts of the equipment; b) for components in series or parallel with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for equipment supplied via an industrial mains plug or for PERMANENTLY CONNECTED APPARATUS, to rely on dedicated over current and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for not via an industrial mains plug or for PERMANENTLY CONNECTED APPARATUS the building installation shall be regarded P 4.1.1 Replace the text of the note by: NOTE For ROUTINE TEST reference is made to EN 50514. N/A ATTACHMENT 1 Page 3 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test 5.4.1 za) (A11:2008) Modify indent za) as follows: za) For a PORTABLE SOUND SYSTEM, a warning that excessive sound pressure from earphones and headphones can cause hearing loss. N/A 5.4.1 (A12:2011) In EN 60065:2002/A1:2006 and EN 60065;2002/A11:2008 Delete the modification in indent za) Add the following clause and annex to the excisting standard and amendments N/A Zx Protection against excessive sound pressure from personal music players N/A Zx.1 General N/A This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players. A personal music player is a portable is designed to allow the user to listen to recorded or broadcast sound or video; and primarily uses headphones or earphones that can be worn in or on or around the ears; and allows the user to walk around while in use. NOTE 1 Examples are hand-held or body-worn portable CD players, MP3 audio players, mobile phones with MP3 type features, PDA’s or similar equipment. A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause. The requirements in this sub-clause are valid for music or video mode only. The requirements do not apply: while the personal music player is connected to an external amplifier; or while the headphones or earphones are not used. NOTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player. The requirements do not apply to: hearing aid equipment and professional equipment; NOTE 3 Professional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment. Result - Remark Verdict ATTACHMENT 1 Page 4 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of 2015. NOTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. For equipment which is clearly designed or intended for use by young children, the limits of EN 71-1 apply. Cont. Zx.2 Equipment requirements No safety provision is required for equipment that complies with the following: equipment provided as a package (personal music player with its listening device), where the acoustic output LAeq,T is ≤ 85 dBA measured while playing the fixed “programme simulation noise” as described in EN 50332-1; and a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is ≤ 27 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” as described in EN 50332-1. NOTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level LAeq,T is meant. See also Zx.5 and Annex Zx. All other equipment shall: a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and b) have a standard acoustic output level not exceeding those mentioned above, and automatically return to an output level not exceeding those mentioned above when the power is switched off; and c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and NOTE 2 Examples of means include visual or audible signals. Action from the user is always required. NOTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off. d) have a warning as specified in Zx.3; and e) not exceed the following: N/A ATTACHMENT 1 Page 5 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Cont. 1) equipment provided as a package (player with Its listening device), the acoustic output shall be ≤ 100 dBA measured while playing the fixed “programme simulation noise” described in EN 50332-1; and 2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be ≤ 150 mV measured as described in EN 50332-2, while playing the fixed “programme simulation noise” described in EN 50332-1. For music where the average sound pressure (long term LAeq,T) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. In this case T becomes the duration of the song. Result - Remark Verdict N/A NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dBA. For example, if the player is set with the programme simulation noise to 85 dBA, but the average music level of the song is only 65 dBA, there is no need to give a warning or ask an acknowledgement as long as the average sound level of the song is not above the basic limit of 85 dBA. Zx.3 Warning The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following: the symbol of Figure 1 with a minimum height of 5 mm; and the following wording, or similar: “To prevent possible hearing damage, do not listen at high volume levels for long periods.” Figure 1 – Warning label (IEC 60417-6044) Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level. N/A ATTACHMENT 1 Page 6 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict Cont. Zx.4 Requirements for listening devices (headphones and earphones) N/A Zx.4.1 Wired listening devices with analogue input N/A With 94 dBA sound pressure output LAeq,T, the input voltage of the fixed “programme simulation noise” described in EN 50332-2 shall be ≥ 75 mV. This requirement is applicable in any mode where the headphones can operate (active or passive), including any available setting (for example builtin volume level control). NOTE The values of 94 dBA – 75 mV correspond with 85dBA – 27 mV and 100 dBA – 150 mV. Zx.4.2 Wired listening devices with digital input N/A With any playing device playing the fixed “programme simulation noise” described in EN 50332-1 (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.). NOTE An example of a wired listening device with digital input is a USB headphone. Zx.4.3 Wireless listening devices In wireless mode: N/A with any playing and transmitting device playing the fixed programme simulation noise described in EN 50332-1; and respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the abovementioned programme simulation noise, the acoustic output LAeq,T of the listening device shall be ≤ 100 dBA. NOTE An example of a wireless listening device is a Bluetooth headphone. Zx.5 Measurement methods Measurements shall be made in accordance with EN 50332-1 or EN 50332-2 as applicable. Unless stated otherwise, the time interval T shall be 30 s. N/A ATTACHMENT 1 Page 7 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict NOTE Test method for wireless equipment provided without listening device should be defined. 6.1 (A11:2008) Replace the entire subclause in EN 60065:2002 and EN 60065:2002/A1:2006 by: Ionizing radiation N/A Apparatus including a potential source of ionizing radiation shall be so constructed that personal protection against ionizing radiation is provided under normal operating conditions and under fault conditions. Compliance is checked by measurement under the following conditions: In addition to the normal operating conditions, all controls adjustable from the outside BY HAND, by any object such as a tool or a coin, and those internal adjustments or pre-sets which are not locked in a reliable manner, are adjusted so as to give maximum radiation whilst maintaining an intelligible picture for 1 h, at the end of which the measurement is made. NOTE 1 Soldered joints and paint lockings are examples of adequate locking. The dose-rate is determined by means of a radiation monitor with an effective area of 10 cm², at any point 10 cm from the outer surface of the apparatus. Moreover, the measurement shall be made under fault conditions causing an increase of the highvoltage, provided an intelligible picture is maintained for 1 h, at the end of which the measurement is made. The dose-rate shall not exceed 1μSv/h (0,1 mR/h) taking account of the background level. NOTE 2 These values appear in Directive 96/29/Euratom of 13th May 1996. A picture is considered to be intelligible if the following conditions are met: - a scanning amplitude of at least 70 % of the usable screen width; - a minimum luminance of 50 cd/m² with locked blank raster provided by a test generator; - a horizontal resolution corresponding to at least 1,5 MHz in the centre, with a similar vertical degradation; - not more than one flashover per 5 min. Z1 (A11:2008) Add the following new clause after Clause 20: Z1 Resistance to candle flame ignition A television set shall be so designed that the likelihood of ignition and the spread of fire caused by a candle flame is reduced. NOTE 1 An apparatus with a viewing screen is Plastic materials of enclosure were class V-1 min. P ATTACHMENT 1 Page 8 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict not regarded to be a television set if it is declared not to be so by the manufacturer. This requirement does not apply to the display screen of rear projection TV’s. NOTE 2 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. NOTE 3 The frame around the screen is not exempted from the requirements. Wood and WOOD-BASED MATERIAL with a thickness of at least 6 mm is considered to fulfil the V-1 requirement when applying CLC/TS 62441. Compliance is checked according to CLC/TS 62441. NOTE 4 The term vertical, as used in the first dash of clause 5.2 of CLC/TS 62441, does not mean a perfectly vertical position. It should be interpreted as any surface that can be touched by the flame of a candle of 150 mm height and 20mm diameter while the candle is still touching the supporting surface. A typical candle used in the home is assumed to be 20 mm diameter. NOTE 5 It is expected that CLC/TS 62441 will in the future be replaced by a standard, at which time that standard will become applicable, subject to a vote by National Committees at the time. General 13.3.1 14 15.1.1 15.2 16.1 16.2 20 Annex B Annex G Annex J.2 Annex N to Delete note 4. Delete note 4 and note 5. Delete notes 1 and 2. Delete note 2. Delete note 1. Delete the note. Delete note 2. Replace note 1 by: In the CENELEC countries listed in IEC 62151, special national conditions apply. Delete the note. Delete the notes of Table J.1. Add after the introduction: For ROUTINE TEST reference is made EN 50333. (Replaced by EN 50514) P General (A2:2010) In IEC 60065:2001/A2 Delete all the “country” notes according to the following list: 5.3 Note 5.4.1 Note 20 Note For special national conditions, see Annex ZB. P Bibliography Additional EN standards. P ATTACHMENT 1 Page 9 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause ZA Requirement + Test Result - Remark Normative references to international publications with their corresponding European publications ZB ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) 2.6.1 DK: The following is added: Verdict P P N/A Certain types of CLASS I apparatus, see 15.1.1, may be provided with a plug not establishing earthing continuity when inserted in Danish socket-outlets Justification: Heavy Current Regulations, Section 107. 3.Z1 (A2:2010) Denmark Add to the end of the subclause P Due to many existing installations where the socket-outlets can be protected with fuses with higher rating than the rating of the socket-outlets the protection for pluggable equipment type A shall be an integral part of the equipment. Justification: In Denmark an existing 13 A socket outlet can be protected by a 20 A fuse. 5.3 (A2:2010) Finland, Norway and Sweden 5.4 (A11:2008) Finland, Norway and Sweden To the end of 5.4 the following is added: To the end of the subclause the following is added: CLASS I apparatus which is intended for connection to the building installation wiring via a plug or an appliance coupler, or both and in addition is intended for connection to other apparatus or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network TERMINALS and ACCESSIBLE parts, have a marking stating that the apparatus must be connected to an earthed MAINS socket-outlet. The marking text in the applicable countries shall be as follows: In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In Norway: “Apparatet må tilkoples jordet stikkontakt” In Sweden: “Apparaten skall anslutas till jordat uttag” CLASS I apparatus which is intended for connection to the building installation wiring via a plug or an appliance coupler, or both and in addition is intended for connection to other No surge suppressor connected to accessible parts. N/A See above. N/A ATTACHMENT 1 Page 10 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict apparatus or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network TERMINALS and ACCESSIBLE parts, have a marking stating that the apparatus must be connected to an MAINS socket-outlet with protective earth. The marking text in the applicable countries shall be as follows: In Finland: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan” In Norway: “Apparatet må tilkoples jordet stikkontakt” In Sweden: "Apparaten skall anslutas till jordat uttag" 5.4.1 (A11:2008) Norway and Sweden To the end of 5.4.1 (after the compliance statement) the following is added: The screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building. Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system. It is however accepted to provide the insulation external to the equipment by an adapter or an interconnection cable with galvanic isolator, which may be provided by e.g. a retailer. The user manual shall then have the following or similar information in Norwegian and Swedish language respectively, depending on in what country the equipment is intended to be used in: “Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing – and to a cable distribution system using coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range (galvanic isolator, see EN 60728-11)” NOTE In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min. Translation to Norwegian (the Swedish text will also be accepted in Norway): “Utstyr som er koplet til beskyttelsesjord via The relevant information shall be provided when the apparatus was sold in these countries. N/A ATTACHMENT 1 Page 11 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator mellom utstyret og kabel-TV nettet.” Translation to Swedish: ”Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall medföra risk för brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.” 13.3.1 NO: To the second paragraph the following is The input voltage range of this added: apparatus covered 230V. In Norway, due to the IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230 V in case of a single earth fault. Justification: Based on a use in Norway of an IT power distribution system where the neutral is not provided. 15.1.1 (A11:2008) Denmark No socket outlet on the equipment. No plug according The text of the Danish SNC in EN 60065:2002 to Heavy Current Regulation, has been modified as follows: section 107-2-D1. To the first paragraph the following is added: In Denmark, supply cords of single-phase appliances having a rated current not exceeding 13 A shall be provided with a plug according to the Heavy Current Regulations Section 107-2-D1. Appliances of CLASS I provided with socketoutlets with earth contact or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with the Heavy Current Regulations, Section 1072-D1 standard sheet DK 2-1a. To the second paragraph the following is added: Socket outlets intended for providing power to CLASS II apparatus with a rated current of 2,5 A shall be in accordance with the Heavy Current Regulation, Section 107-2-D1 standard sheet DKA 1-4a. Other current ratings socket outlets shall be in compliance with the Heavy Current Regulation, Section 107-2-D1 standard sheet DKA 1-3a or DKA 1-3b. To the third paragraph the following is added: Mains socket-outlets with earthing contact shall P N/A ATTACHMENT 1 Page 12 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict be in compliance with the Heavy Current Regulation, Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a or DK 1-7a. Justification: Heavy Current Regulations, Section 107-2-D1 15.1.1 No such plug provided. IE: Apparatus which is fitted with a flexible cable or cord shall be provided with a 13 A plug in accordance with Statutory Instrument 525:97, “13 A Plugs and Conversion Adapters for Domestic Use Regulations:1997. N/A Justification: SI 525: 1997 15.1.1 NO: Mains socket-outlets mounted on CLASS II apparatus shall comply with the specifications given in CEE Publ. 7 as far as a applicable, with the following amendments: § 8 Dimensions a 2.5 A 250 V two-pole socket-outlets for electronic apparatus shall comply with the enclosed Standard Sheet I. No mains socket-outlets used. N/A § 24 Mechanical strength A 2,5 A 250 V socket-outlets for CLASS II electronic apparatus are tested as specified in 12.1.3 of EN 60065. Also the protecting rim shall be tested Justification: Act of 24 May 1929 relating to supervision of electrical installation (TEA 1929/FEL 1998). 15.1.1 UK: Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug shall be fitted with a ”standard plug” in accordance with Statutory Instrument 1768: 1994: The Plugs and Sockets etc. (Safety) Regulations 1994, unless P ATTACHMENT 1 Page 13 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict exempted by those Regulations. NOTE ”Standard plug” is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. Justification: SI 1768: 1994 J.2 NO: After Table J.1 the following is added: In Norway, due to the IT power distribution system used, the a.c. MAINS supply voltage is considered to be equal to the line-to-line voltage, and will remain 230 V in case of a single earth fault. Justification: Based on a use in Norway of an IT power distribution system where the neutral is not provided. P ZC ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) N/A 5.1 IT: Additional markings on the outside of the TV receiver in Italian language The relevant information shall be provided when the apparatus was sold in this country. N/A IT:User instructions in Italian language including a conformity declaration N/A IT: Certification number on the back cover N/A 6.1 DE: The following requirement applies: No such devices. For the operation of any cathode ray tube intended for the display of visual images operating at an acceleration voltage exceeding 40 kV, authorization is required, or application of type approval (Bauartzulassung) and marking. Justification: German ministerial decree against ionizing radiation (Röntgenverordnung), in force since 2002-07-01, implementing the European Directive 96/29/EURATOM. NOTE Contact address: Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Tel.: Int+49-531-592-6320, Internet: http://www.ptb.de N/A 14 SE: Switches containing mercury such as thermostats, relays and level controllers are not allowed. Justification: Ordinance (1990:944) on Prohibition in Connection with handling. Importation and exportation of Chemical Products (Certain Cases) N/A ATTACHMENT 1 Page 14 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60065 DANISH NATIONAL DIFFERENCES Audio, video and similar electronic apparatus – Safety requirements Differences according to ................ : National standard DS/EN 60065/A2: 2010 Attachment Form No. ..................... : DK_ND_IEC60065K Attachment Originator ................... : UL International Demko A/S Master Attachment ......................... : 2011-03 Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. General National Differences P The clause in this Attachment Form is an additional Danish difference which was introduced by EN 60065/A2: 2010. P Please note that this Attachment Form does not cover the Common European Modifications (Group Differences) introduced by EN 60065/A2: 2010 why compliance with those modifications have to be documented elsewhere. 3.Z1 Special national conditions (if any) N/A Denmark N/A Add to the end of the subclause Due to many existing installations where the socket-outlets can be protected with fuses with higher rating than the rating of the socket-outlets the protection for pluggable equipment type A shall be an integral part of the equipment. Justification: In Denmark an existing 13 A socket outlet can be protected by a 20 A fuse ATTACHMENT 1 Page 15 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC 60065 SWEDEN NATIONAL DIFFERENCES Audio, video and similar electronic apparatus – Safety requirements Differences according .................... : SS-EN 60065, 3rd EDITION Attachment Form No. ..................... : Attachment Form Originator ......... : TUV Rheinland Taiwan Master Attachment Form ............... : IECEE CB Bulletin on 2011-04-19 Clause Requirement + Test Result - Remark Annex B Replace NOTE 1 by Apparatus not for connecting with TELECOMMUNICATION NETWORKS. In the CENELEC countries listed in IEC 62151, special national conditions apply. Add the following: All subclauses given below are subclauses of IEC 62151:2000 (ref. Corrigendum 1 and 2 to IEC 62151). Subclause 4.1.1 (Corrigendum 2): Add after the first paragraph: NOTE - In Sweden, CLASS I equipment which is intended for connection to the building installation via a non-industrial plug or a non-industrial appliance coupler, or both and in addition is intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and ACCESSIBLE parts, have a marking stating that the equipment must be connected to an earthed mains socket -outlet. The marking text shall be as follows: "Apparaten skall anslutas till jordat uttag” Subclause 5.3.1 (Corrigendum 1): Add after the first test specifications paragraph: NOTE 1 In Finland, Norway and Sweden, there are additional requirements for the insulation. Renumber the existing note as note 2. For additional requirements for the insulation in Sweden in the NOTE 1 the following text is added between the first and second paragraph (this text is identical to the text in EN 60950-1:2001): If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation Verdict N/A ATTACHMENT 1 Page 16 of 16 Report No.: 17706513 001 IEC 60065 ATTACHMENT Clause Requirement + Test of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in the accordance with the compliance clause below and in addition: - passes the test and inspection criteria of 13.6 with an electric strength test of 10.3 using the test voltage of 1,5 kV multiplied by 1,6, and - is subject to routine testing for electric strength during manufacturing, using a test voltage of 1,5 kV (for performance of the test see N.2.1). It is permitted to bridge this insulation with a capacitor complying with IEC 60384-14:1993, subclass Y2. A capacitor classified Y3 according to IEC 6038414:1993, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by IEC 60384-14, which in addition to the Y3 testing, is tested with an Impulse test of 2.5kV defined in IEC 62151, subclause 6.2.1; - the additional testing shall be performed on all the test specimens as described in IEC 6038414; - the Impulse test of 2.5kV is to be performed before the Endurance Test in IEC 60384-14 in the sequence of tests as described in IEC 6038414. Subclause 5.3.2 (Corrigendum 1): Add after the fourth dash: NOTE - In Sweden, exclusions are applicable for equipment which is intended for connection to the building installation wiring using screw terminals or other reliable means, and for equipment which is intended for connection to the building installation wiring via an industrial plug and socket -outlet or an appliance coupler, or both, complying with IEC 60309 or with a comparable national standard Result - Remark Verdict ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic001 Front appearance Pic002 Back appearance Rev. 1 Page 1 of 6 ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic003 Back appearance without stand Pic004 Inside view without back cover Rev. 1 Page 2 of 6 ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic005 Power switch Pic006 Marking for signal connectors Rev. 1 Page 3 of 6 ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic007 Marking for signal connectors Pic008 Power supply board Rev. 1 Page 4 of 6 ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic009 Power supply board Pic010 Mainboard Rev. 1 Page 5 of 6 ATTACHMENT 2 Photo Documentation Report No.: 17706513 001 Type Designation: LTDN40K321UWTSEU, UB40EC591UWTSEU Pic011 Mainboard Rev. 1 Page 6 of 6