Test Report issued under the responsibility of:
TEST REPORT
IEC 60065
Audio, video and similar electronic apparatus - Safety requirements
Report Number. ..............................: 17706513 001
Date of issue ...................................: See cover page
Total number of pages ...................: See cover page
Applicant’s name ............................: Hisense Electric Co., Ltd.
Address ...........................................: No. 218, Qianwangang Road, Qingdao Economic & Technology
Development Zone, Shandong 266555, P.R. China
Test specification:
Standard ..........................................: EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 +A12:2011
Test procedure................................: COC-LVD
Non-standard test method .............: N/A
Test Report Form No. .....................: IEC60065K
Test Report Form(s) Originator.....: Intertek Semko AB
Master TRF ......................................: Dated 2010-10
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
Test item description .....................: LCD TV
Trade Mark ......................................: Hisense
Manufacturer ...................................: Same as applicant
Model/Type reference ....................: LTDN40K321UWTSEU, UB40EC591UWTSEU
Ratings ............................................: AC 220-240V, 50Hz, 90W, Class II
Page 3 of 21
Report No.: 17706513 001
Testing procedure and testing location:
Testing Laboratory:
Testing location/ address ........................ :
TÜV Rheinland / CCIC (Qingdao) Co., Ltd.
6F, No.2 Bldg., No.175 Zhuzhou Road, Qingdao 266101,
P.R. China
Associated Laboratory:
Testing location/ address ........................ :
Tested by (name + signature) ....... :
See cover page
Approved by (name + signature) .. :
See cover page
Testing procedure: TMP
Testing location/ address ........................ :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Testing procedure: WMT
Testing location/ address ........................ :
Tested by (name + signature) ....... :
Witnessed by (name + signature) . :
Approved by (name + signature) .. :
Testing procedure: SMT
Testing location/ address ........................ :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Supervised by (name + signature) :
Testing procedure: RMT
Testing location/ address ........................ :
Tested by (name + signature) ....... :
Approved by (name + signature) .. :
Supervised by (name + signature) :
Page 4 of 21
Report No.: 17706513 001
List of Attachments (including a total number of pages in each attachment):
- ATTACHMENT 1 - National Differences (16 pages)
- ATTACHMENT 2 – Photo documentation (6 pages)
- ATTACHMENT 3 - Test report No. 17706468 001, 52 pages with attachments of National Differences, 17
pages and Photo Documentation, 10 pages, issued on 2015-05-29 by TÜV Rheinland / CCIC (Qingdao)
Co., Ltd.
Note: Total number of pages in each attachment is indicated in individual attachment.
Summary of testing: 1) According to the “General product information”, relevant tests were tested on
LTDN40K321UWTSEU. The appliance complied with the requirements after the evaluation.
2) EMF was evaluated in test report No. 17706517 001.
Tests performed (name of test and test clause):
Testing location:
Marking and instructions– Clause 5
Heating under normal operation conditions – Clause 7.1
Terminals – Clause 9.1.4
Resistance to external forces – Clause 9.1.7
Insulation resistance & Dielectric strength – Clause 10.3
Fault conditions – Clause 11.2
Bump Test – Clause 12.1.1
Impact Test – Clause 12.1.3
Stress Relief Test – Clause 12.1.5
Fixing of actuating elements – Clause 12.2
Remark: Relevant tests were tested on the sample
registered No. A000196174-001. The sample is an
engineering sample without serial number.
Unless otherwise indicated, all tests were
performed at the location stated in “Testing
procedure and testing location”.
Table 14 completely listed for reference.
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions.
Refer to the ATTACHMENT 1 of this test report for details.
Copy of marking plate
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
<LTDN40K321UWTSEU>
Page 5 of 21
<UB40EC591UWTSEU>
Report No.: 17706513 001
Page 6 of 21
Report No.: 17706513 001
Test item particulars .................................................. :
Classification of installation and use ...................... : Class II
Supply Connection .................................................... : Detachable supply cord
Possible test case verdicts:
- test case does not apply to the test object .......... : N/A (Not Applicable)
- test object does meet the requirement ................. : P (Pass)
- test object does not meet the requirement .......... : F (Fail)
Testing:
Date of receipt of test item ........................................ : 05 May, 2015
Date (s) of performance of tests .............................. : 08 May, 2015 to 29 May, 2015
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................ :
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .............................. : Hisense Electric Co., Ltd.
No. 218, Qianwangang Road, Qingdao Economic &
Technology, Development Zone, Shandong
266555, P.R. China
General product information:
The EUTs are ordinary LCD TVs with LED backlight, which are normally for home use within the scope of
IEC/EN 60065.
As declared by client, LTDN40K321UWTSEU and UB40EC591UWTSEU are identical with the the
approved type LTDN40K321UWAU in original CB test report No. 17706468 001 issued by TÜV Rheinland
/ CCIC (Qingdao) Co., Ltd. except that
- Mainboard changed (Main IC not changed)
- Rated input changed into 220-240V 50Hz 90W from 100-240V 50/60Hz 95W
- Addpower switch and primary wire
- One AC connetor added on power supply board to connect power switch
- Material for enclosure changed
- Alternative AC inlet sources added, which has the same rating and specification with the original one.
According to above changes, the consturction was checked and relevant tests listed in page 4 were
performed.
Page 7 of 21
Report No.: 17706513 001
IEC 60065
Clause
Requirement + Test
5
Marking and instructions
5.1
5.2
Result - Remark
Verdict
P
Comprehensible and easily discernible
Markings are permanent,
comprehensible and easily
discernible on the apparatus.
Permanent durability against water and petroleum
spirit
The same material and printing
means for the marking label.
No additional test is necessary.
P
N/A
a) Identification, maker .............................................: See marking label
P
b) Model number or type reference ..........................: See marking label
P
c) Class II symbol if applicable ................................: Used according to IEC 604175172.
P
d) Nature of supply ....................................................: Used according to IEC 604175032.
P
e) Rated supply voltage ...........................................: See marking labels
P
f) Mains frequency if safety dependant ...................: See marking labels
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ............................................................................:
N/A
Measured current or power consumption ................:
N/A
Deviation % (max 10%) ...........................................:
N/A
h) Rated current or power consumption for apparat- For use with single phase
us intended for connection to an a.c. mains supply .: mains supply.
P
Measured current or power consumption ................: See below
P
See appended table.
Measured current or power consumption for
Television set ............................................................:
P
Deviation % (max 10%) ...........................................: Not more than 10%
P
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
No such terminals
N/A
c) Markings on supply output terminals
No such terminals
N/A
a) Use of triangle with exclamation mark
The symbol was marked on
circuit diagram for safety
related components.
b) marking on loudspeaker grille, IEC 60417-5036
No such construction.
5.4
Instructions for use
Instruction manual for safety
was available and English
version was checked.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Provided in user manual.
P
b) Hazardous live terminals, instructions for wiring
No such terminals.
N/A
c) Instructions for replacing lithium battery
No such battery used.
N/A
5.3
P
N/A
Page 8 of 21
Report No.: 17706513 001
IEC 60065
Clause
Requirement + Test
Result - Remark
d) Class I earth connection warning
Class II apparatus.
e) Instructions for multimedia system connection
Provided in user manual.
Provided in user manual.
h) Warning: protective film on CRT face
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
N/A
P
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
g) Warning: battery exposure to heat
Verdict
P
N/A
MAINS plug on supply cord
used as disconnect device.
P
c) Instructions for permanently connected
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
7.1.1
Temperature rise of accessible parts
N/A
7.1.2
Temperature rise of parts providing electrical
insulation
N/A
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
N/A
7.1.4
Temperature rise of windings
N/A
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
N/A
9
Electric shock hazard under normal operating conditions
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin Applied to antenna and all
(10 N); test probe D of IEC 61032
input/output signal connectors.
P
9.1.7
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
See above
P
Resistance to external forces
See below
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Compliance is checked by
inspection.
P
b) Test hook of fig. 4 for 10 s (20 N)
Compliance is checked by
inspection.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
10
Lower input power
consumption than previously
approved type. No additional
test is necessary. (see
appended table)
Insulation requirements
N/A
P
Page 9 of 21
Report No.: 17706513 001
IEC 60065
Clause
Requirement + Test
Result - Remark
10.3
Insulation resistance and dielectric strength between (see appended table)
mains terminals
11
Fault conditions
11.2
Heating under fault condition
P
N/A
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
Verdict
(see appended table)
P
P
Lower input power
consumption than previously
approved type. No additional
test is necessary.
P
Flames extinguish within 10 seconds
N/A
No hazard from softening solder
N/A
P
Soldered terminations not used as protective
mechanism
11.2.1
Measurement of temperature rises
See above
P
11.2.2
Temperature rise of accessible parts
See above
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
See above
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
See above
P
11.2.5
Temperature rise of windings
See above
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
P
12
Mechanical strength
P
Page 10 of 21
Report No.: 17706513 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
12.1.1
Bump test where mass >7 kg
The mass of the EUT is more
than 7.0kg.
P
12.1.3
Impact hammer test
No hazards.
P
Steel ball test
2J is carried to other enclosure
parts. No hazardous live parts
become accessible.
P
12.1.5
Thermoplastic enclosures stress relief test
A sample consisting of the
complete apparatus is
subjected in a circulating air
oven to a temperature 70°C,
after the test, no hazardous
live parts can be accessible.
P
12.2
Fixing of knobs, push buttons, keys and levers
P
14
Components
P
14.6
Switches
(see appended table)
P
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
An approved switch used and
comply the relative standard
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 610581 subclause 13.1 and has making/breaking action
independent of speed of actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 610581 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 61058-1
N/A
Socket outlet current marking correct
N/A
Page 11 of 21
7.1
Report No.: 17706513 001
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ......................................... :
Cond.
Un (V)
Hz
In (A)
0W/ 0.46W max
Pn (W) Uout (V) Pout (W) Operating Condition / Status
Max. normal load with 1/8 non-clipped max. audio output power
1.
240
50
0.42
86.6
--
--
ATV mode
2.
240
50
0.42
86.5
--
--
AV mode
3.
240
50
0.42
86.6
--
--
Component mode
4.
240
50
0.42
86.5
--
--
HDMI mode
5.
198
50
0.47
86.2
--
--
ATV mode
6.
220
50
0.44
86.0
--
--
ATV mode
7.
240
50
0.42
86.6
--
--
ATV mode
8.
264
50
0.43
86.1
--
--
ATV mode
Notes: The input power was lower than test results for approved type (88.9W at 100V input and 88.7W at
240V input) in original test report 17706468 001. No additional tests necessary
10.3
TABLE: insulation resistance measurements
P
R (MΩ)
Required R (MΩ)
Unit: Primary circuits (L/N) to back cover and power switch
(RI)
>100
4
Unit: Primary circuits (L/N) to signal connectors (RI)
>100
4
Primary wire (RI)
>100
4
Insulation resistance R between:
Notes: -10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Unit: Primary circuits (L/N) to back cover and power switch
(RI)
4240 (peak)
No
Unit: Primary circuits (L/N) to signal connectors (RI)
4240 (peak)
No
Primary wire (RI)
4240 (peak)
No
Notes: -11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
See below
—
Frequency (Hz) ........................................................ :
60
—
o
Ambient temperature ( C) ....................................... :
No.
1.
Component
One speaker
Fault
s-c
o
22.0 C
—
dT (K) / Component Other results
(include description and test duration)
--
Input voltage: 264V
Input: 81.8W;
Both speakers did not work. The other parts
worked as normal. No hazards.
Duration: 10 minutes
Page 12 of 21
No.
Component
Fault
2.
USB output
(mainboard)
s-c
3.
USB output
(mainboard)
o-l
Report No.: 17706513 001
dT (K) / Component Other results
(include description and test duration)
--
Input voltage: 264V
Input: 84.4W
The EUT worked as normal except for the
USB port.
Duration: 10 minutes
Input: 198V
Duration: 120 minutes
Input: 108.0W
Normal operation until overload to 4.0A. No
breakdown, no hazards.
—
Winding temperature rise measurements
o
Ambient temperature t1 ( C) .................................. :
—
o
—
Ambient temperature t2 ( C) .................................. :
Supplementary information:
1) In fault column, where s-c=short circuit, o-l=overload;
2) The input power of USB overload is lower than the test results in previous test report 17706468 001. No
additional heating test was necessary on new model with the same construction.
14
TABLE: list of critical components and materials
P
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Mark(s) of
1)
conformity
Power supply
board
Hisense Electric
Co., Ltd.
HLL-4855WP
Input: AC 100240V, 50/60Hz,
3A Max;
output: DC12V,
3A; DC16V,
1.5A; DC200V
400mA.
IEC/EN 60065
Tested with
equipment
-PCB
Changzhou
Aohong
Electronics Co.,
Ltd
AOH-2
V-0, 1.5mm Min. UL 94
UL 796
Thick, 130C.
-(Alternative)
Interchangeable
Interchangeable V-0, 1.5mm Min. UL 94
UL 796
Thick, 120C
min.
-AC inlet
(XP802)
Zhang Jiagang
SA-2S
Huajie Electronic
Co., Ltd
250V AC, 2.5A
70C
IEC/EN 60320-1 TUV
R 50018670
-(Alternative)
Zhang Jiagang
SA-2S C, SA-2S 250V AC, 2.5A
Huajie Electronic D, SA-2S D1,
70C
Co., Ltd
SA-2S E, SA-2S
C-2
IEC/EN 60320-1 TUV
R 50187984
-(Alternative)
Zhang Jiagang
SA-2S H, SA-2S 250V AC, 2.5A
Huajie Electronic L, SA-2S J, SA- 70C
Co., Ltd
2S K, SA-2S M,
SA-2S N
IEC/EN 60320-1 TUV
R 50256890
UL E303981
UL
Page 13 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
-(Alternative)
Zhang Jiagang
Huajie
Electronic Co.,
Ltd
SA-2S-127
SA-2S-129
SA-2S-165
250V AC, 2.5A
70C
IEC/EN 60320-1 TUV R
50304415
-(Alternative)
Zhe Jiang Bei Er ST-A03 series
Jia Electronic
Co., Ltd.
250V AC, 2.5A
70C
IEC/EN 60320-1 ENEC ENEC00636
VDE 40014833
-(Alternative)
TECX-UNIONS
ELECTRONIC
CO., LTD
SO-222
250V AC, 2.5A
70°C
IEC/EN 60320-1 VDE 40020337
-Fuse (F801)
Littelfuse Inc.
382
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40018250
IEC/EN 60127-3
-(Alternative)
XC Electronics
(Shenzhen)
Corp. Ltd.
5TR
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40036800
IEC/EN 60127-3
-(Alternative)
Conquer
Electronics Co.,
Ltd.
MET
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40017155
IEC/EN 60127-3
-(Alternative)
Dongguan
Walter Electric
Co., Ltd
2000
T6.3AL,
AC 250V
IEC/EN 60127-1 VDE 40018787
IEC/EN 60127-3
-VDR (RV801)
Thinking
Electronic
lndustrial Co.,
Ltd.
TVR10621-V
620V, fulfil IEC
60950-1 Annex
Q
IEC 61051-1
IEC 61051-2
VDE 005944
-(Alternative)
Thinking
Electronic
lndustrial Co.,
Ltd.
TVR10621-D
620V, fulfil IEC
60950-1 Annex
Q
IEC 61051-1
IEC 61051-2
VDE 40021243
-(Alternative)
EPCOS OHG
S10KV621E2K1 620V, fulfil IEC
60950-1 Annex
Q
IEC 61051-1
IEC 61051-2
VDE 40027582
-Filter (L801,
L802)
Jiangsu Lettall
Electronics Co.,
Ltd.
LCL-3505-HP
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Haining Lianfeng LCL-020-P
Dongjin
Electronic Co.,
Ltd.
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Qingdao Jingshi
Electronic
CO.,LTD
LCL-H1806
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Dezhou Sanhe
Electric Co., Ltd.
LCL-35-012
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Weihai Dongxing LCH-20016-01
Electronics Co.,
Ltd.
130C
IEC/EN 60065
Tested with
equipment
-(Alternative)
Linyi Zhongrui
Electronics Co.,
Ltd.
130C
IEC/EN 60065
Tested with
equipment
ZRI-15015-03
Mark(s) of
1)
conformity
Page 14 of 21
Standard
Mark(s) of
1)
conformity
Jiangsu Huaxing LCL-1806D-153 130C
Electric Co., Ltd
IEC/EN 60065
Tested with
equipment
-- bobbin
Changchun
T375J
Plastics Co., Ltd.
Phenolic,
150C, V-0
UL 94
UL E59481
-- (Alternative)
Interchangeable
Interchangeable Phenolic,
150C; V-0
UL 94
UL
-NTC (RT801)
Interchangeable
Interchangeable 5Ω at 25C
UL 1434
UL
-Bleeder
Interchangeable
resistor (R802,
R804, R809,
R970, R971,
R972)
Interchangeable 1MΩ, 1/4W
IEC/EN 60065
Tested with
equipment
-X2 Capacitor
( C813, C846)
Xiamen
Faratronic Co.,
Ltd.
MKP62
0.47μFmax.,
IEC/EN 60384AC 275V,110C 14
VDE 40000358
-(Alternative)
Xiamen
Faratronic Co.,
Ltd.
MKP61
0.47μF max.,
IEC/EN 60384AC 275V,100C 14
VDE 40007424
-(Alternative)
Nanjing Tengen MKP
Rongguangda
Electronics
(Group) Co., Ltd.
0.47μF max.,
IEC/EN 60384AC 275V, 100C 14
VDE 40028680
-Electrolytic
capacitor
(C860)
Interchangeable
Interchangeable 82μF, 450V
min., 105C
IEC/EN 60065
Tested with
equipment
-Y1 Capacitor
(C803, C804,
C809)
Anshan
Electronic
Ceramic Co.,
Ltd.
CT7
C803=C804=
470pF max,
C809= 1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 40011817
-(Alternative)
TDK Xiamen
Co., Ltd.
CD
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 85C
IEC/EN 6038414
VDE 124321
-(Alternative)
Yinan Don’s
Electronic
Component Co.,
Ltd.
CT81
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 135256
-(Alternative)
Guangdong
F
South Hongming
Electronic
Science and
Technology Co.,
Ltd.
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 40036393
-(Alternative)
Murata
Manufacturing
Co., Ltd.
C803=C804=
470pF max,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE 40002831
Object / part
No.
Manufacturer/
trademark
-(Alternative)
Type / model
KX
Technical data
Report No.: 17706513 001
Page 15 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Mark(s) of
1)
conformity
-(Alternative)
Kunshan
Wansheng
Electronics Co.,
Ltd.
CT7
C803=C804=
470pF max.,
C809=1000pF
max., AC250V
min., 125C
IEC/EN 6038414
VDE
40012143
-Transformer
(T831)
Jiangsu Lettall
Electronic Co.,
Ltd.
BK-10-05HM
Class B, refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
-(Alternative)
Haining Lianfeng BCK-70-05HM
Dongjin
Electronic Co.,
Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Yueqing Jingmi
Electron
Electronic Co.,
Ltd.
XW40EFD2B21H015
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Dezhou Sanhe
Electric Co., Ltd.
SANHE-35-249
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Weihai Dongxing BCK-EFD-3335
Electronics Co.,
Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-- Windings
Interchangeable
UL 1446
UL
-- Bobbin
Sumitomo
PM-9820
Bakelite Co., Ltd.
Phenolic,
150C; V-0
UL 94
UL E41429
(Alternative)
Chang Chun
T375J
Plastics Co., Ltd.
Phenolic,
150C; V-0
UL 94
UL E59481
(Alternative)
Interchangeable
Interchangeable Phenolic,
150C; V-0
UL 94
UL
--Insulation
tape
Yahua Pressure
Sensitive Glue
Co., Ltd.
CT
130C, flame
retardant
UL 510
UL E165111
--Margin tape
Yahua Pressure
Sensitive Glue
Co., Ltd.
WF
130C, flame
retardant
UL 510
UL E165111
-Transformer
(T901)
Haining Lianfeng BCK-70-39FB
Dongjin
Electronic Co.,
Ltd.
-(Alternative)
Jiangsu Lettall
Electronics Co.,
Ltd.
-(Alternative)
Interchangeable 130C
Class B, refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
BK-20-12FB
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
Yueqing Jingmi
Electron
Electronic Co.,
Ltd.
XW40EFD2A38H012
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Dezhou Sanhe
Electric Co., Ltd.
SANHE-35-273
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Weihai Dongxing BCK-EFD-3542
Electronics Co.,
Ltd
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
Page 16 of 21
Object / part
No.
Manufacturer/
trademark
Type / model
-- Windings
Interchangeable
-- Cover
E I Dupont De
Nemours & Co
Inc.
-- Bobbin
Standard
Mark(s) of
1)
conformity
Interchangeable 130C
UL 1446
UL
FR50(+)(f1)
V-0, PA66, 0.5
mm thick min.
UL 94
UL E41938
PM9820
Sumitomo
Bakelite Co., Ltd.
Phenolic,
150C; 0.8 mm
thick min. V-0
UL 94
UL E41429
(Alternative)
T375J
Chang Chun
Plastics Co., Ltd.
Phenolic,
150C; 0.8 mm
thick min. V-0
UL 94
UL E59481
(Alternative)
Interchangeable
Interchangeable Phenolic,
150C; 0.8 mm
thick min. V-0
UL 94
UL
--Margin tape
Yahua Pressure
Sensitive Glue
Co., Ltd.
WF
130C, flame
retardant
UL 510
UL E165111
--(Alternative)
Interchangeable
Interchangeable 130C, flame
retardant
UL 510
UL
--Insulation
tape
Yahua Pressure
Sensitive Glue
Co., Ltd.
CT
130C, flame
retardant,
UL 510
UL E165111
--(Alternative)
Suzhou
Mailaduona
Electric Material
Co., Ltd
JY312
130C, flame
retardant,
UL 510
UL E188295
--(Alternative)
Interchangeable
Interchangeable 130C, flame
retardant,
UL 510
UL
-Transformer
(T902)
Weihai Dongxing BCK-25-1605
Electronics Co.,
Ltd.
Class B, refer to IEC/EN 60065
table 14.3.3&
IEC 60085
14.3.4 for details
Tested with
equipment
-(Alternative)
Yueqing Jingmi
Electron
Electronic Co.,
Ltd.
XW2025EPCB05H003
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Jiangsu Lettall
Electronics Co.,
Ltd.
BK-10-05YG
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Haining Lianfeng BCK-20-1605
Dongjin
Electronic Co.,
Ltd.
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
-(Alternative)
Dezhou Sanhe
Electric Co. Ltd.
SANHE-19-065
Same as above
IEC/EN 60065
IEC 60085
Tested with
equipment
--Pri. Windings
Interchangeable
Interchangeable 130C
UL 1446
UL
TEX-E
UL 2353
UL E206440
IEC/EN 60950-1 VDE 006735
IEC/EN 60065
--Sec. windings FURUKAWA
ELECTRIC CO
LTD
Technical data
Report No.: 17706513 001
130C, triple
insulation wire
Page 17 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
-(Alternative)
Shanghai Lucy
Trade Co., Ltd.
TIW-B
130C, triple
insulation wire
UL 2353
UL E305883
IEC/EN 60950-1 VDE 40023686
IEC/EN 60065
--Bobbin
Interchangeable
Interchangeable Phenolic,
150C; V-0
UL 94
UL
--Insulating
tape
Interchangeable
Interchangeable 130C, flame
retardant
UL 510
UL
--Tubing
Interchangeable
Interchangeable 200C, 600V,
VW-1
UL 224
UL
-Photocoupler
(N881, N891)
Everlight
Electronics Co.,
Ltd.
EL817
Int.=6.0mm
min.,
Ext.=7.7mm
min.,
dti. =0.5mm
min., 110C
IEC/EN 60065
DEMKO DIEC/EN 60950-1 00764-A1
-(Alternative)
VISHAY
Semiconductour
GmBH
VO617A
Int.=5.2mm
min.,
Ext.=7.8mm
min.,
dti. =0.6mm
min., 100C
IEC/EN 60065
FIMKO NCS/FI
IEC/EN 60950-1 26764 A1
-(Alternative)
Lite-On
Technology
Corporation
LTV-817
Int.=5.2mm
min.,
Ext.=7.7mm
min.,
dti.=0.6mm
min., 110C
IEC/EN 60065
Intertek
IEC/EN 60950-1 1312430
-(Alternative)
AUK Corp.
PC-17K1
Int.=8.0mm,
Ext.=8.0mm,
dti. ≥0.4mm,
100C
IEC/EN 60065
VDE 40010361
IEC/EN 60950-1 Semko 1118939
Main IC
Media Tek Inc.
MT5657
--
--
PCB
Interchangeable
Interchangeable V-0, 1.6mm min. UL 94
UL 796
thick, 120C
min.
Hisense Electric
Co., Ltd.
HD396DU-B01
Mark(s) of
1)
conformity
Mainboard
--
UL
Others
LCD Panel
IEC/EN 60065
39.6 inch TFT
LCD with LED
backlight.
Total power
consumption for
LED Backlight is
46.2W
Tested with
equipment
Page 18 of 21
Type / model
Technical data
Report No.: 17706513 001
Standard
Object / part
No.
Manufacturer/
trademark
Main switch
Zhangjiagang
HF-606(TV)-P
Huafeng
HF-606(TV)-S
Electronic
Connector &
Component Co.,
Ltd.
Rocker switch, IEC/EN 61058-1 VDE 40008136
TV-5, 8A/128A
TUV
AC 250V,
R50120515
T85/55, 10E3,
Level 3
(Alternative)
Alps Electric
Co., Ltd
SDDJE
Rocker switch, IEC/EN61058-1
10(6)A, AC
250V, 1E4, T55,
Level 3
VDE 40026948
(Alternative)
Zhangjiagang
Huajie
Electronic Co.,
Ltd.
PS8
Rocker switch, IEC/EN61058-1
6(4)A, AC 250V,
5E4, T85/55,
Level 3
VDE 40027662
TUV
R50191561
(Alternative)
Zhejiang LECI
RS601D
Electronics Co.,
Ltd.
6(4)A, AC 250V, IEC/EN 61058-1 VDE 40017430
1E4, T55, Level
TUV
3; 8A/128A, AC
R50210040
250V, 1E4, T55.
(Alternative)
Zhejiang
KCD1-104-2
Zhongxun
Electronics Co.,
Ltd
10(6)A or 6/12A IEC/EN 61058-1 TUV
AC 250V, 1E4,
R50264134
T55
(Alternative)
ZheJiang
Beierjia
Rocker switch, IEC/EN61058-1
12(4)A, AC
250V, 10E3,
T55
PS8A-11
Electronics Co.,
Ltd
Mark(s) of
1)
conformity
VDE 40024550
Primary wire
Interchangeable AWM1672
VW-1, 105C,
300V, 20AWG,
reinforced
insulation
UL 758
UL
Insulating
sheet
SE42B
Suzhou Omay
Optical Materials
Co., Ltd.
PC, 0.5mm
thick, V-0, 80C
UL 94
UL E249605
(Alternative)
Chengdu
KLX FRPCKanglongxin
870B
Plastics Co., Ltd.
PC, 0.5mm
thick, V-0, 80C
UL 94
UL E315185
AC connector
I-Sheng Electric
Wire & Cable
Co., Ltd.
IS-037
AC 250V, 2.5A
IEC/EN 60320-1 VDE 40026164
(Alternative)
I-Sheng Electric
Wire & Cable
Co., Ltd.
IS-033
AC 250V, 2.5A
IEC/EN 60320-1 VDE 40026860
(Alternative)
Taiwan Linetek
Electronic Co.,
Ltd.
LS-7H
AC 250V, 2.5A
IEC/EN 60320-1 VDE 40028570
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd
YS-65
AC 250V, 2.5A
IEC/EN 60320-1 VDE 40020913
Page 19 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
(Alternative)
Weihai Honglin
Electronic Co.,
Ltd
HL-028
2.5A, AC 250V
IEC/EN 60320-1 VDE 40039499
(Alternative)
Weihai Honglin
Electronic Co.,
Ltd
HL-028S
2.5A, AC 250V
IEC/EN 60320-1 VDE 40029835
Main Plug
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
YS-2
250VAC,16A
VDE 0620-1
VDE 123226
(Alternative)
I-Sheng Electric
Wire & Cable
Co., Ltd.
SP-026A
250VAC,16A
VDE0620-1
VDE 40016019
(Alternative)
Shenzhen
Xiekang Electric
Co., Ltd.
XK-36
250VAC, 16A
VDE 0620-1
VDE 40026243
(Alternative)
Interchangeable
Interchangeable 250VAC, 16A
VDE 0620-1
VDE
(Alternative)
Shenzhen
Xiekang Electric
Co., Ltd.
XK-01
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 40009009
(Alternative)
I-Sheng Electric
Wire & Cable
Co., Ltd.
SP-021A
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 40013649
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
YS-3
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 112875
(Alternative)
Longkou Jin
Sheng
Electronics
Products Co.,
Ltd.
LFD-215
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 40027592
(Alternative)
Zhejiang Yuehua YP205
Telecommunicati
on Co., Ltd.
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 40013170
(Alternative)
Taiwan Line Tek
Electronic Co.,
Ltd.
LP-21
250VAC, 2.5A
VDE 0620-101
EN 50075
VDE 40009324
(Alternative)
Interchangeable
Interchangeable 250VAC, 2.5A
VDE 0620-101
EN 50075
VDE or TUV
(Alternative)
Shenzhen
Xiekang Electric
Co., Ltd.
XK-28
250VAC, 5A
BS 1363-1
Intertek
ASTA 972
(Alternative)
Shanghai
Yusheng
Enterprise
Development
Co., Ltd.
YS-55
250VAC, 5A
BS 1363-1
BSI KM68299
Mark(s) of
1)
conformity
Page 20 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Mark(s) of
1)
conformity
(Alternative)
Taiwan Line Tek
Electronic Co.,
Ltd.
LP-61L
250VAC, 5A
BS 1363-1
BSI KM55112
(Alternative)
Zhejiang Yuehua YP317
Telecommunicati
on Co., Ltd.
250VAC, 5A
BS 1363-1
BSI KM512007
(Alternative)
Interchangeable
Interchangeable 250VAC, 5A
BS 1363-1
BSI, Intertek or
TUV
Power Cord
Zhejiang Yuehua H03VVH2-F
Telecommunicati H05VVH2-F
on Co., Ltd.
2x0.75mm
2
IEC 60227
VDE 0281-5
AS/NZS 60227
VDE 112929
SAA Q06048
(Alternative)
Long Kou Jin
H03VVH2-F
Sheng Electronic
Products Co.,
Ltd.
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 126716
(Alternative)
I-Sheng Electric
Wire & Cable
Co., Ltd.
2x0.75mm²
VDE 0281-5
IEC 60227
VDE 40006070
(Alternative)
Mainland Electric H03VVH2-F
Wire & Cable
Co., Ltd.
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 40010355
(Alternative)
Shenzhen
Xiekang Electric
Co., Ltd.
H03VVH2-F
2x0.75mm
2
IEC 60227
VDE 0281-5
VDE 40029225
(Alternative)
Interchangeable
H03VVH2-F
H05VVH2-F
2x0.75mm
2
IEC 60227 or
VDE 0281-5
VDE or
equivalent
Front
Enclosure
Cheil Industries
Inc Chemicals
Div
Huizhou Wote
Advanced
Materials Co
Ltd
Asia Int’L
Enterprise
(Hongkong)
Co., Ltd
Orinko (Hefei)
Advanced
Plastic Co., Ltd
LG
Chem(Tianjin)
Engineering
Plastics Co Ltd
Teijin
Chemicals Ltd
LS-1159(R)
V-1, Min.
1.6mm thick.
UL 94
UL E115797
2000
V-0, Min.
1.6mm thick.
UL 94
UL E310240
A2200FR(#)
V-0, Min.
1.6mm thick.
UL 94
UL E252275
PC/ABS-551X
V-0, Min.
1.6mm thick.
UL 94
UL E328304
LUPOY GN5(j)1F(#)
V-0, Min.
1.6mm thick.
UL 94
UL E302314
RN-7715(#)
V-0, Min.
1.6mm thick.
UL 94
UL E98529
V-0, Min.
1.8mm thick.
UL 94
UL E330547
(Alternative)
(Alternative)
(Alternative)
(Alternative)
(Alternative)
H03VVH2-F
Rear Enclosure Qingdao Guoen PS3001ZScience &
600A(b)
Technology
Co., Ltd.
Page 21 of 21
Report No.: 17706513 001
Object / part
No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Mark(s) of
1)
conformity
(Alternative)
Huizhou Wote
Advanced
Materials Co.,
Ltd.
51(x)FR
V-0, Min.
1.8mm thick.
UL 94
UL E310240
(Alternative)
Orinko (Hefei)
Advanced
Plastic Co Ltd
HIPS-2230
V-0, Min.
1.8mm
thickness.
UL 94
UL E328304
Plastic for
stand
Asia Int'l
Enterprise
(Hong Kong)
Ltd
60G6F
V-0, Min.
2.0mm thick.
UL 94
UL E252275
Notes:
1) Provided evidence ensures the agreed level of compliance.
2) Parts in bold are different from the list in original CB test report.
The End of this test Report
ATTACHMENT 1
Page 1 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to ............... :
EN 60065:2002 + A1:2006 + A11:2008 + A2:2010 + A12:2011
Attachment Form No. ..................... :
EU_GD_IEC60065K_II
Attachment Originator ................... :
Intertek Semko AB
Master Attachment ......................... :
Date (2011-08)
Copyright © 2010 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
IEC 60065, GROUP DIFFERENCES (CENELEC common modifications (EN))
Clause
Requirement + Test
Contents
Add the following annexes:
Annex ZA (normative) Other international publications quoted in this standard
with the references of the relevant European publications (See the CB Bulletin)
Annex ZB (nominative) Special national conditions
Annex ZC (informative) A-deviations
Definition
2.2.Z1
(A11:2008)
Add after the definition 2.2.12 the following new
definition:
PORTABLE SOUND SYSTEM
small battery powered audio equipment:

whose prime purpose is to listen to recorded
or broadcasted sound; and

that uses headphones or earphones that can
be worn in or on or around the ears; and
Result - Remark
Verdict
P
N/A
 that allows the user to walk around
NOTE Examples are mini-disc or CD players,
MP3 audio players or similar equipment.
2.2
(A12:2011)
In EN 60065:2002/A11:2008
Delete the definition 2.2.Z1
P
ATTACHMENT 1
Page 2 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
3.1
Add the following indent at the end of the list
- Exposure to excessive sound pressures
from headphones or earphones
NOTE A new method of measurement is
described in EN 50332-1, Sound system
equipment: Headphones and earphones
associated with portable audio equipment
– Maximum sound pressure level measurement
methodology and limit considerations – Part 1:
General method for ”one package equipment”,
and in EN 50332-2, Sound system equipment:
Headphones and earphones associated with
portable audio equipment – Maximum sound
pressure level measurement methodology and
limit considerations – Part 2: Guidelines to
associate sets with headphones coming from
different manufacturers.
N/A
3.1
(A12:2011)
In EN 60065:2002
Delete the addition of indent regarding sound
pressure excessive
N/A
3.Z1
(A2:2010)
After 3.2 add a new clause 3.Z1:
To protect against excessive current, shortcircuits and earth faults in MAINS, protective
devices shall be included either as integral parts
of the equipment or as parts of the building
installation, subject to the following, a), b) and c):
a) except as detailed in b) and c), protective
devices necessary to comply with the
requirements of 11 shall be included as parts of
the equipment;
b) for components in series or parallel with the
mains input to the equipment such as the supply
cord, appliance coupler, r.f.i. filter and switch,
short-circuit and earth fault protection may be
provided by protective devices in the building
installation;
c) it is permitted for equipment supplied via an
industrial mains plug or for PERMANENTLY
CONNECTED APPARATUS, to rely on dedicated
over current and short-circuit protection in the
building installation, provided that the means of
protection, e.g. fuses or circuit breakers, is fully
specified in the installation instructions.
If reliance is placed on protection in the building
installation, the installation instructions shall so
state, except that for not via an industrial mains
plug or for PERMANENTLY CONNECTED
APPARATUS the building installation shall be
regarded
P
4.1.1
Replace the text of the note by: NOTE For
ROUTINE TEST reference is made to EN 50514.
N/A
ATTACHMENT 1
Page 3 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
5.4.1
za)
(A11:2008)
Modify indent za) as follows:
za) For a PORTABLE SOUND SYSTEM, a
warning that excessive sound pressure from
earphones and headphones can cause hearing
loss.
N/A
5.4.1
(A12:2011)
In EN 60065:2002/A1:2006 and EN
60065;2002/A11:2008
Delete the modification in indent za)
Add the following clause and annex to the
excisting standard and amendments
N/A
Zx Protection against excessive sound pressure from personal
music players
N/A
Zx.1 General
N/A
This sub-clause specifies requirements for
protection against excessive sound pressure from
personal music players that are closely coupled
to the ear. It also specifies requirements for
earphones and headphones intended for use with
personal music players.
A personal music player is a portable
is designed to allow the user to listen to
recorded or broadcast sound or video; and
primarily uses headphones or earphones that
can be worn in or on or around the ears; and
allows the user to walk around while in use.
NOTE 1 Examples are hand-held or body-worn portable CD
players, MP3 audio players, mobile phones with MP3 type
features, PDA’s or similar equipment.
A personal music player and earphones or
headphones intended to be used with personal
music players shall comply with the requirements
of this sub-clause.
The requirements in this sub-clause are valid for
music or video mode only.
The requirements do not apply:
while the personal music player is connected to
an external amplifier; or
while the headphones or earphones are not
used.
NOTE 2 An external amplifier is an amplifier which is not part
of the personal music player or the listening device, but which
is intended to play the music as a standalone music player.
The requirements do not apply to:
hearing aid equipment and professional
equipment;
NOTE 3 Professional equipment is equipment sold through
special sales channels. All products sold through normal
electronics stores are considered not to be professional
equipment.
Result - Remark
Verdict
ATTACHMENT 1
Page 4 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
analogue personal music players (personal
music players without any kind of digital
processing of the sound signal) that are brought
to the market before the end of 2015.
NOTE 4 This exemption has been allowed because this
technology is falling out of use and it is expected that within a
few years it will no longer exist. This exemption will not be
extended to other technologies.
For equipment which is clearly designed or
intended for use by young children, the limits of
EN 71-1 apply.
Cont.
Zx.2 Equipment requirements
No safety provision is required for equipment that
complies with the following:
equipment provided as a package (personal
music player with its listening device), where
the acoustic output LAeq,T is ≤ 85 dBA measured
while playing the fixed “programme simulation
noise” as described in EN 50332-1; and
a personal music player provided with an
analogue electrical output socket for a listening
device, where the electrical output is ≤ 27 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
as described in EN 50332-1.
NOTE 1 Wherever the term acoustic output is used in this
clause, the 30 s A-weighted equivalent sound pressure level
LAeq,T is meant. See also Zx.5 and Annex Zx.
All other equipment shall:
a) protect the user from unintentional acoustic
outputs exceeding those mentioned above; and
b) have a standard acoustic output level not
exceeding those mentioned above, and
automatically return to an output level not
exceeding those mentioned above when the
power is switched off; and
c) provide a means to actively inform the user of
the increased sound pressure when the
equipment is operated with an acoustic output
exceeding those mentioned above. Any means
used shall be acknowledged by the user before
activating a mode of operation which allows for an
acoustic output exceeding those mentioned
above. The acknowledgement does not need to
be repeated more than once every 20 h of
cumulative listening time; and
NOTE 2 Examples of means include visual or audible signals.
Action from the user is always required.
NOTE 3 The 20 h listening time is the accumulative listening
time, independent how often and how long the personal music
player has been switched off.
d) have a warning as specified in Zx.3; and
e) not exceed the following:
N/A
ATTACHMENT 1
Page 5 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Cont.
1) equipment provided as a package (player
with Its listening device), the acoustic output shall
be ≤ 100 dBA measured while playing the fixed
“programme simulation noise” described in EN
50332-1; and
2) a personal music player provided with an
analogue electrical output socket for a listening
device, the electrical output shall be ≤ 150 mV
measured as described in EN 50332-2, while
playing the fixed “programme simulation noise”
described in EN 50332-1.
For music where the average sound pressure
(long term LAeq,T) measured over the duration of
the song is lower than the average produced by
the programme simulation noise, the warning
does not need to be given as long as the average
sound pressure of the song is below the basic
limit of 85 dBA. In this case T becomes the
duration of the song.
Result - Remark
Verdict
N/A
NOTE 4 Classical music typically has an average sound
pressure (long term LAeq,T) which is much lower than the
average programme simulation noise. Therefore, if the player
is capable to analyse the song and compare it with the
programme simulation noise, the warning does not need to be
given as long as the average sound pressure of the song is
below the basic limit of 85 dBA.
For example, if the player is set with the programme
simulation noise to 85 dBA, but the average music level of the
song is only 65 dBA, there is no need to give a warning or ask
an acknowledgement as long as the average sound level of
the song is not above the basic limit of 85 dBA.
Zx.3 Warning
The warning shall be placed on the equipment, or
on the packaging, or in the instruction manual
and shall consist of the following:
the symbol of Figure 1 with a minimum height
of 5 mm; and
the following wording, or similar:
“To prevent possible hearing damage, do not
listen at high volume levels for long periods.”
Figure 1 – Warning label (IEC 60417-6044)
Alternatively, the entire warning may be given
through the equipment display during use, when
the user is asked to acknowledge activation of the
higher level.
N/A
ATTACHMENT 1
Page 6 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Cont.
Zx.4 Requirements for listening devices (headphones and earphones)
N/A
Zx.4.1 Wired listening devices with analogue
input
N/A
With 94 dBA sound pressure output LAeq,T, the
input voltage of the fixed “programme simulation
noise” described in EN 50332-2 shall be ≥ 75 mV.
This requirement is applicable in any mode where
the headphones can operate (active or passive),
including any available setting (for example builtin volume level control).
NOTE The values of 94 dBA – 75 mV correspond with 85dBA
– 27 mV and 100 dBA – 150 mV.
Zx.4.2 Wired listening devices with digital
input
N/A
With any playing device playing the fixed
“programme simulation noise” described in EN
50332-1 (and respecting the digital interface
standards, where a digital interface standard
exists that specifies the equivalent acoustic level),
the acoustic output LAeq,T of the listening device
shall be ≤ 100 dBA.
This requirement is applicable in any mode where
the headphones can operate, including any
available setting (for example built-in volume level
control, additional sound feature like equalization,
etc.).
NOTE An example of a wired listening device with digital input
is a USB headphone.
Zx.4.3 Wireless listening devices
In wireless mode:
N/A
with any playing and transmitting device playing
the fixed programme simulation noise described
in EN 50332-1; and
respecting the wireless transmission standards,
where an air interface standard exists that
specifies the equivalent acoustic level; and
with volume and sound settings in the listening
device (for example built-in volume level control,
additional sound feature like equalization, etc.)
set to the combination of positions that maximize
the measured acoustic output for the abovementioned programme simulation noise, the
acoustic output LAeq,T of the listening device shall
be ≤ 100 dBA.
NOTE An example of a wireless listening device is a
Bluetooth headphone.
Zx.5 Measurement methods
Measurements shall be made in accordance with
EN 50332-1 or EN 50332-2 as applicable.
Unless stated otherwise, the time interval T shall
be 30 s.
N/A
ATTACHMENT 1
Page 7 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
NOTE Test method for wireless equipment provided without
listening device should be defined.
6.1
(A11:2008)
Replace the entire subclause in EN 60065:2002
and EN 60065:2002/A1:2006 by:
Ionizing radiation
N/A
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under
fault conditions.
Compliance is checked by measurement under
the following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND,
by any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE 1 Soldered joints and paint lockings are
examples of adequate locking.
The dose-rate is determined by means of a
radiation monitor with an effective area of 10 cm²,
at any point 10 cm from the outer surface of the
apparatus.
Moreover, the measurement shall be made under
fault conditions causing an increase of the highvoltage, provided an intelligible picture is
maintained for 1 h, at the end of which the
measurement is made.
The dose-rate shall not exceed 1μSv/h (0,1
mR/h) taking account of the background level.
NOTE 2 These values appear in Directive
96/29/Euratom of 13th May 1996.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70 % of the
usable screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least
1,5 MHz in the centre, with a similar vertical
degradation;
- not more than one flashover per 5 min.
Z1
(A11:2008)
Add the following new clause after Clause 20:
Z1 Resistance to candle flame ignition
A television set shall be so designed that the
likelihood of ignition and the spread of fire caused
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is
Plastic materials of enclosure
were class V-1 min.
P
ATTACHMENT 1
Page 8 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
not regarded to be a television set if it is declared
not to be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed
because this technology is falling out of use and it
is expected that within a few years it will no
longer exist. This exemption will not be extended
to other technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil
the V-1 requirement when applying CLC/TS
62441.
Compliance is checked according to CLC/TS
62441.
NOTE 4 The term vertical, as used in the first
dash of clause 5.2 of CLC/TS 62441, does not
mean a perfectly vertical position. It should be
interpreted as any surface that can be touched by
the flame of a candle of 150 mm height and
20mm diameter while the candle is still touching
the supporting surface. A typical candle used in
the home is assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which
time that standard will become applicable, subject
to a vote by National Committees at the time.
General
13.3.1
14
15.1.1
15.2
16.1
16.2
20
Annex B
Annex G
Annex J.2
Annex N
to
Delete note 4.
Delete note 4 and note 5.
Delete notes 1 and 2.
Delete note 2.
Delete note 1.
Delete the note.
Delete note 2.
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Delete the note.
Delete the notes of Table J.1.
Add after the introduction: For ROUTINE TEST reference is made
EN 50333. (Replaced by EN 50514)
P
General
(A2:2010)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
Note
5.4.1
Note
20
Note
For special national conditions, see Annex ZB.
P
Bibliography
Additional EN standards.
P
ATTACHMENT 1
Page 9 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
ZA
Requirement + Test
Result - Remark
Normative references to international publications
with their corresponding European publications
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Verdict
P
P
N/A
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socket-outlets
Justification: Heavy Current Regulations, Section
107.
3.Z1
(A2:2010)
Denmark
Add to the end of the subclause
P
Due to many existing installations where the
socket-outlets can be protected with fuses with
higher rating than the rating of the socket-outlets
the protection for pluggable equipment type A
shall be an integral part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
5.3
(A2:2010)
Finland, Norway and Sweden
5.4
(A11:2008)
Finland, Norway and Sweden
To the end of 5.4 the following is added:
To the end of the subclause the following is
added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a marking
stating that the apparatus must be connected to
an earthed MAINS socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
No surge suppressor
connected to accessible parts.
N/A
See above.
N/A
ATTACHMENT 1
Page 10 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
5.4.1
(A11:2008)
Norway and Sweden
To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the
building and there is normally no equipotential
bonding system within the building. Therefore the
protective earthing of the building installation
need to be isolated from the screen of a cable
distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
The relevant information shall
be provided when the
apparatus was sold in these
countries.
N/A
ATTACHMENT 1
Page 11 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
13.3.1
NO: To the second paragraph the following is
The input voltage range of this
added:
apparatus covered 230V.
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
15.1.1
(A11:2008)
Denmark
No socket outlet on the
equipment. No plug according
The text of the Danish SNC in EN 60065:2002
to Heavy Current Regulation,
has been modified as follows:
section 107-2-D1.
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socketoutlets with earth contact or which are intended to
be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 1072-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet
DKA 1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or
DKA 1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
P
N/A
ATTACHMENT 1
Page 12 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
be in compliance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DK
1-3a, DK 1-5a or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
15.1.1
No such plug provided.
IE: Apparatus which is fitted with a flexible cable
or cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13
A Plugs and Conversion Adapters for Domestic
Use Regulations:1997.
N/A
Justification: SI 525: 1997
15.1.1
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply with the
enclosed Standard Sheet I.
No mains socket-outlets used.
N/A
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA
1929/FEL 1998).
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a
mains socket conforming to BS 1363 by means of
that flexible cable or cord and plug shall be fitted
with a ”standard plug” in accordance with
Statutory Instrument 1768: 1994: The Plugs and
Sockets etc. (Safety) Regulations 1994, unless
P
ATTACHMENT 1
Page 13 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
exempted by those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification: SI 1768: 1994
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
P
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
N/A
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
The relevant information shall
be provided when the
apparatus was sold in this
country.
N/A
IT:User instructions in Italian language including a
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
DE: The following requirement applies:
No such devices.
For the operation of any cathode ray tube
intended for the display of visual images
operating at an acceleration voltage exceeding 40
kV, authorization is required, or application of
type approval (Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
N/A
ATTACHMENT 1
Page 14 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
DANISH NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according to ................ :
National standard DS/EN 60065/A2: 2010
Attachment Form No. ..................... :
DK_ND_IEC60065K
Attachment Originator ................... :
UL International Demko A/S
Master Attachment ......................... :
2011-03
Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
General
National Differences
P
The clause in this Attachment Form is an additional Danish difference which was
introduced by EN 60065/A2: 2010.
P
Please note that this Attachment Form does not cover the Common European
Modifications (Group Differences) introduced by EN 60065/A2: 2010 why
compliance with those modifications have to be documented elsewhere.
3.Z1
Special national conditions (if any)
N/A
Denmark
N/A
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with
fuses with higher rating than the rating of the
socket-outlets the protection for
pluggable equipment type A shall be an integral
part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse
ATTACHMENT 1
Page 15 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ATTACHMENT TO TEST REPORT IEC 60065
SWEDEN NATIONAL DIFFERENCES
Audio, video and similar electronic apparatus – Safety requirements
Differences according .................... : SS-EN 60065, 3rd EDITION
Attachment Form No. ..................... :
Attachment Form Originator ......... :
TUV Rheinland Taiwan
Master Attachment Form ............... :
IECEE CB Bulletin on 2011-04-19
Clause
Requirement + Test
Result - Remark
Annex B
Replace NOTE 1 by
Apparatus not for connecting
with TELECOMMUNICATION
NETWORKS.
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Add the following:
All subclauses given below are subclauses of IEC
62151:2000 (ref. Corrigendum 1 and 2 to IEC
62151).
Subclause 4.1.1 (Corrigendum 2):
Add after the first paragraph:
NOTE - In Sweden, CLASS I equipment which is
intended for connection to the building installation
via a non-industrial plug or a non-industrial
appliance coupler, or both and in addition is
intended for connection to other equipment or a
network shall, if safety relies on connection to
protective earth or if surge suppressors are
connected between the network terminals and
ACCESSIBLE parts, have a marking stating that
the equipment must be connected to an earthed
mains socket -outlet.
The marking text shall be as follows:
"Apparaten skall anslutas till jordat uttag”
Subclause 5.3.1 (Corrigendum 1):
Add after the first test specifications paragraph:
NOTE 1 In Finland, Norway and Sweden, there
are additional requirements for the insulation.
Renumber the existing note as note 2.
For additional requirements for the insulation in
Sweden in the NOTE 1 the following text is added
between the first and second paragraph (this text
is identical to the text in EN 60950-1:2001):
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation
Verdict
N/A
ATTACHMENT 1
Page 16 of 16
Report No.: 17706513 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
of at least 0,4 mm, which shall pass the electric
strength test below.
If this insulation forms part of a semiconductor
component (e.g. an optocoupler), there is no
distance through insulation requirement for the
insulation consisting of an insulating compound
completely filling the casing, so that
CLEARANCES and CREEPAGE DISTANCES do
not exist, if the component passes the electric
strength test in the accordance with the
compliance clause below and in addition:
- passes the test and inspection criteria of 13.6
with an electric strength test of 10.3 using the test
voltage of 1,5 kV multiplied by 1,6, and
- is subject to routine testing for electric strength
during manufacturing, using a test voltage of 1,5
kV (for performance of the test see N.2.1).
It is permitted to bridge this insulation with a
capacitor complying with IEC 60384-14:1993,
subclass Y2.
A capacitor classified Y3 according to IEC 6038414:1993, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by
IEC 60384-14, which in addition to the Y3 testing,
is tested with an Impulse test of 2.5kV defined in
IEC 62151, subclause 6.2.1;
- the additional testing shall be performed on all
the test specimens as described in IEC 6038414;
- the Impulse test of 2.5kV is to be performed
before the Endurance Test in IEC 60384-14 in
the sequence of tests as described in IEC 6038414.
Subclause 5.3.2 (Corrigendum 1):
Add after the fourth dash:
NOTE - In Sweden, exclusions are applicable for
equipment which is intended for connection to the
building installation wiring using screw terminals
or other reliable means, and for equipment which
is intended for connection to the building
installation wiring via an industrial plug and
socket -outlet or an appliance coupler, or both,
complying with IEC 60309 or with a comparable
national standard
Result - Remark
Verdict
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic001 Front appearance
Pic002 Back appearance
Rev. 1
Page 1 of 6
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic003 Back appearance without stand
Pic004 Inside view without back cover
Rev. 1
Page 2 of 6
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic005 Power switch
Pic006 Marking for signal connectors
Rev. 1
Page 3 of 6
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic007 Marking for signal connectors
Pic008 Power supply board
Rev. 1
Page 4 of 6
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic009 Power supply board
Pic010 Mainboard
Rev. 1
Page 5 of 6
ATTACHMENT 2
Photo Documentation
Report No.:
17706513 001
Type Designation:
LTDN40K321UWTSEU, UB40EC591UWTSEU
Pic011 Mainboard
Rev. 1
Page 6 of 6