TECHNICAL SPECIFICATIONS CTX 98OO DSi ™ Benefits: • TSA-certified • Meets ECAC Performance Standard 3 for EDS • Multiplexed • BHS integrated • Dynamic Screening, changing detection modes via BHS • Continuous one-meter wide conveyor belt and tunnel • Single X-ray-generator, dual-energy design provides 2D and 3D organic/inorganic material discrimination General 1 (includes scanner, input, and output modules) Image Display and Management 1 (continuation) Overall Dimensions (w x h x l) 94.5 in. × 85.5 in. × 189.0 in. (2400 mm × 2177 mm × 4803 mm) User Interface3 Tunnel Structure Rectangular (max. width at conveyor edge) Tunnel Opening (max. height at max. width) Tunnel Opening (max. height at conveyor ctr.) Tunnel Opening (max. width at max. height) 40.2 in. (1020 mm) 16.5 in. (425 mm) 24.0 in. (620 mm) 30.5 in. (785 mm) DVD-R/CD-RW Drive Network Ready Input Power 230/110 VAC: 50/60 Hz; 10/20 Amps Environment 1 (operating) System temperature and humidity operating specifications: Conveyor Height from Floor 35.0 in. (889 mm) Weight (uncrated) 14,800 lbs. (6713 kg) Weight (crated) 17,200 lbs. (7802 kg) Input Power Service (scanner) 48 hours Color Printer 380V 50Hz, 400V 50Hz or 480V 60Hz, 40 Amp, 3-phase ∆ + PE Input Power Service (FSE workstation) Maximum Power Rating 24 kVA Voltage/Frequency Tolerance ±10%/±1% Supplied Power Cable 16 ft. (5 m), flexible cord with plug Max. Heat Dissipation 13 kW Warranty 1 year = 380 VAC Service Relative Humidity (%RH) Tunnel Opening Image Soft keys, mouse, keyboard and key-switch Storage4 100 -5 0 Temperature (˚C) 5 10 15 20 25 30 35 40 45 80 60 40 20 20 40 Image Display and Management 1 Workstation Monitors (2) 17.0 in. (432 mm) Image Presentation 3D Volumetric Rendering CT Monitor Resolution 648 x 648 pixels = 480 VAC Service Optimal Temperature 60 80 100 Temperature (˚F) 5 to 38°C (40 to 100°F) 120 TECHNICAL SPECIFICATIONS CTX 98OO DSi > Dimensional Drawings (dimensions in inches [millimeters]). 2400 mm (94.5 in.) 4803 mm (189.0 in.) 1735 mm (68.3 in.) 1379 mm (54.2 in.) 2177 mm (85.5 in.) 620 mm (24.0 in.) 889 mm (35.0 in.) 1020 mm (40.0 in.) 1369 mm (53.8 in.) Environment 1,2 (storage) > Safety Shipping Crates Not waterproof • Emergency stops Storage Dry/weather-proof location Temperature –7 to 49°C (19 to 120°F) • Radiation Safety conforms to US code of Federal Regulations Title 21, Section 1020.40 Relative Humidity 10 to 95% noncondensing • X-ray shielded cabinet with safety interlocks Luggage 5 (max. cross-sectional dimensions) > Optional Features At Maximum Width (w x h x l) Long Bag 39.3 in. x 16.7 in. x 98.45 in. (1000 mm x 425 mm x 2500 mm) • CTX™ PLC At Maximum Height (w x h x l) 30.0 in. x 23.6 in. x 98.4 in. (760 mm x 600 mm x 2500 mm) Maximum Weight 110.0 lbs. (50 kg) • Operator workstation • Multiplexing capability • Image archiving Baggage Handling System Interface • Extended hours support Communication Interface ControlNew, ProfibusDP • External UPS Discrete Signals Belt sync. and sensors Emergency Stop 24VDC Bag Tracking Two IDs; Unique ID (IATA) and BHS tracking number Bag Status (decision) Upon request by unique ID Machine Status On, Off, Fault...with Fault Codes Meets TSA CBIS Interface Requirements Morpho Detection Tel: +1 510 739 2400 Fax: + 510 739 6400 www.morphodetection.com Headquarters: 7151 Gateway Boulevard, Newark, CA 94560 USA 1 Some items are optional; Morpho representatives can provide more detailed information 2 Temperatures are dry bulb; humidity is noncondensing 3 Morpho representatives can provide more detailed information regarding operator user interface functions 4 Optional Morpho storage product 5 Values are nominal and dependent on BHS conveyor width ©2010-2015 Morpho Detection, LLC. All rights reserved. CTX and CTX 9800 DSi are trademarks of Morpho Detection, LLC. Technical specifications subject to change without notice and should not be used as a site design document. EXRVh10/15 GBEN15 TS 07/15 4567 mm (180.2 in.)