Series MA PTL PTLCC Power Transfer Load Center Featuring an Upgradeable Transfer Switch (Manual to Automatic) The Series MA Power Transfer Load Center (PTLC), manufactured for Intersect by ASCO® Power Technologies, is a family of integrated load centers that provides the flexibility to easily upgrade the manual transfer switch to an automatic transfer switch as site demands evolve. Series MA panels safeguard critical loads from transients and load transfer spikes using Strikesorb® surge suppression. Independent test data confirms that 40 mm Strikesorb suppression modules can withstand 100 kA (8 x 20 µs) strikes with 0% change in clamping voltage. These high-performance modules outperform traditional protection, providing multi-strike resistance with a 20+ year service life. Featuring an ASCO manual transfer switch, Series MA PTLCs can be retrofitted with an automatic transfer switch as needs change. It’s as simple as ordering the upgrade package. ASCO-certified technicians perform the changeout in the field, reinstating the one year manufacturer’s warranty on the panel and the ATS. UL Listings remain intact. Series MA panels support a variety of single- and threephase service voltages and can be housed in NEMA 1 or NEMA 3R enclosures. MA1240061U The integrated Square D load center provides 42 circuit breaker positions, giving you the flexibility to distribute power to a variety of site equipment. For more information about the Series MA panels, or other PTLC models, e-mail Intersect today at solutions@intersectinc.us. Intersect, Inc. ™ Mailine power protection Product Configuration MA1220061U MA1222561U MA1230061U MA1240061U 240/120; 1Ø; 200 amp; 22K AIC 240/120; 1Ø; 225 amp; 22K AIC 240/120; 1Ø; 300 amp; 22K AIC 240/120; 1Ø; 400 amp; 22K AIC MA3320061U MA3322561U MA3330061U MA3340061U 208/120; 3Ø; 200 amp; 22K AIC 208/120; 3Ø; 225 amp; 22K AIC 208/120; 3Ø; 300 amp; 22K AIC 208/120; 3Ø; 400 amp; 22K AIC MAUpgrade Upgrades MTS to ATS; includes 3 hours of travel, labor and materials; 1-year extended panel warranty Suppression Technology Tec hnolo echnolo hnologg y type Strikesorb™ 40 mm, 120 V modules (one per phase, L-N) UL cer tif ica tion tifica ication UL 1449 2nd Edition - Feb. 2007 Nominal operating voltage 120 V Suppressed voltage rating (SVR) UL 1449, Feb 2007 tested <500 V Maximum continuous operating voltage (MCOV) 150 V Let through voltage 1600 General Data Manual Transfer Switch Enclosure dimensions (H x W x D) 200 and 225 amp panels NEMA 1 – 66 x 22 x 6 inches NEMA 3R – 84 x 29 x 12 inches All other MA Series panels NEMA 1 – 78 x 31 x 7.25 inches NEMA 3R – 85.25 x 31 x 13 inches Enclosure type NEMA 1 NEMA 3R (optional) Weight NEMA 1 – 215 lbs (approx.) NEMA 3R – 355 lbs (approx.) Sing le-phase ser vice vvolta olta Single-phase oltagg e options 200, 225, 300, or 400 amp 240/120 VAC T hr ee-phase ser vice vvolta olta hree-phase oltagg e options 200, 225, 300, or 400 amp 208/120 VAC UL cer tif ica tion tifica ication UL 67 Listed Panel Type ASCO Non-Automatic Series 300L Tr ansf er de vice ansfer device • Solenoid mechanism operation with external handle per UL 1008 • True double throw operation ce cir cuit br eak er s Sour Source circuit break eaker • Normal & Emergency • 200A, 225 A, 300 A, and 400 A available • 60 Hz W ithstand cur r ent rraa ting (W CR) (UL 1008) (WCR) 22,000 amps ica tion & Standar UL cer tif tifica ication Standardd compliances • UL 1008 Listed • NFPA 110 • NEC Articles 700, 701, and 702 • CUL • NEMA ICS 10-1993 Load Center Load center type Square D type NQOD Circuit breaker positions 42 circuits Circuit breaker type Square D bolt-on or plug-in branch devices UL cer tif ica tion tifica ication UL 67 Listed 1400 Automatic Transfer Switch Type (after upgrade) ASCO – Series 300L Tr ansf er de vice ansfer device • Single solenoid operation • Microprocessor controls • True double throw operation A v aila ailabb le inter interrr upt cur currr ent (AIC) 22,000 UL cer tif ica tion & other saf ety compliances tifica ication safety • UL 1008 (ASCO Series 300, UL File E51276) • NFPA 110 • NEC Articles 700, 701, and 702 • CSA 1200 residual voltage (V) Series Number 1000 800 600 400 200 0 0 10 20 30 40 50 60 80 90 100 A v aila ailabb le inter interrr upt cur currr ent (AIC) UL Recognized for direct installation behind any breaker in any circuit with an AIC rating of 85 kA rms without use of additional fusing. UL Recognized for direct installation in any circuit having an available fault current up to 200,000 A rms, when protected by a 4000 A Class L fuse. R emote alar ming Form “C” relay Multiple surge resilience 2000 hits at 10 kA (8/20 µs) (Represents the ability to withstand multiple strikes with less than a 5% change in characteristics.) Long dur or mance duraa tion sur surgg e perf perfor 250 hits at 500 A, 2 msec square waveform (IEEE C62.11) Intersect, Inc. ™ All specifications subject to change without notice. ASCO® is a registered trademark of ASCO Power Technologies. Strikesorb is a registered trademark of Raycap Corporation. © Intersect, Inc. 2003-2006. Rev 111906. 70 surge current (kA) P.O. Box 753 – Liberty Lake WA 99019 – USA Phone: 509.926.6163 – Fax: 509.921.5981 www.intersectinc.us