SRCOOL33K Self-Contained, Row-Based Air

advertisement
NEW PRODUCT ANNOUNCEMENT
Simplifies Installation and
Saves Energy to Reduce Costs
SRCOOL33K Self-Contained,
Row-Based Air Conditioning Unit
Highly Efficient Data Center Cooling
Ideal for high-density data center equipment, SRCOOL33K provides up to
33,000 BTU (9.7 kW) of close-coupled cooling in a 42U rack form factor.
Simplifies Installation
• Self-contained unit with built-in condenser and convenient L6-30P plug
can be fully installed by IT staff
• Does not require a costly startup service, electrician or HVAC contractor
• Does not require plumbing, piping, special ductwork or extra components
• Built-in evaporator eliminates condensation through the exhaust air stream—
no floor drain or water collection tank required
Saves Energy
• Variable-speed, DC-inverter-driven compressor and microprocessorcontrolled electronic expansion valve (EEV) allow precise cooling
adjustments—no more wasteful, noisy cycling between off and full blast
• Dynamically scales cooling output to the ideal level for the application
• Soft-start feature prevents inrush current spikes from wasting energy and
introducing disruptive line noise, voltage fluctuations and circuit overloads
• Reduces power consumption and operating costs up to 33%
• Close-coupled airflow path improves hot-aisle/cold-aisle efficiency by
supplying cold air high in the cold aisle
Additional Benefits
• Innovative design offers outstanding price/performance ratio
• Convenient LCD control panel, Modbus interface, dry contact interface and
optional network card provide local and remote monitoring and control
of temperature, fan speed, alarms and logging via front-panel buttons,
Modbus protocol, SNMP, Web, SSH or telnet
• Eco-friendly R410A refrigerant meets environmental standards worldwide
Model: SRCOOL33K
→∞
20
A Better Way to Cool
More Effective
More Efficient
Tripp Lite SRCOOL33K
SRCOOL33K
Hot
Aisle
Soft-start feature prevents inrush current spikes from wasting energy
and introducing line noise, voltage fluctuations and overloads
Competitor
Cold
Aisle
Hot
Aisle
Cold
Aisle
Full
SRCOOL33K dynamically scales cooling output
to the ideal level for the application
0
TEMPERATURE
TEMPERATURE
Current Draw
After reaching the temperature set
point, SRCOOL33K throttles back
and operates in a highly efficient
temperature maintenance mode
→∞
20
Time (minutes)
Legacy On/Off Cycle (Competitor)
Inrush spikes are >50A
Side View
Compressor
is on full blast
(100%)
Full
Side View
SRCOOL33K removes hot air from the hot aisle and supplies cold air high in the cold aisle,
allowing cold air to sink and distribute across equipment intakes. This optimized, closecoupled airflow path promotes temperature uniformity from top to bottom. The competitor
Current Draw
Massive inrush
current wastes
energy and
introduces
disruptive line
noise, voltage
fluctuations
and potential
overloads
supplies cold air low in the cold aisle, causing undesirable heat concentration and increased
intake air temperatures above the rack midpoint.
Less Noisy
Compressor
is off
SRCOOL33K
Competitor
100
0
→∞
20
Time (minutes)
Acoustic Noise (dBA)
SRCOOL33K’s variable-speed, DC-inverter-driven compressor and microprocessor-controlled
electronic expansion valve (EEV) allow precise cooling adjustments, providing more efficient
operation than the competitor’s legacy “on/off” cycle. SRCOOL33K’s soft-start feature also
prevents line noise, voltage disruptions and potential circuit overloads introduced by the
competitor’s massive inrush spikes, which occur repeatedly with each “on” cycle.
78
65
57
60
40
20
More Convenient
Full
82
80
You can monitor and control temperature,
0
humidity, fan speed, logging and alarms
locally and remotely through the easy-to-use
1 ft
Distance
5 ft
LCD control panel, Modbus interface, dry
SRCOOL33K’s precise, efficient cooling technology allows it to operate at lower acoustic
contact interface or optional network card
noise levels than the competitor. (Note: Acoustic noise was measured with systems at full
(SNMP, Web, SSH, telnet).
“on” level.)
Specifications
Model
0
SRCOOL33K
AC Input
200-240 V,
50/60 Hz
AC Input
Connection
Cooling
Capacity
L6-30P (10 ft. 20 33,000 BTU/hr
cord) or Hardwire
(9.7 kW)
Inrush
Current
Refrigerant
Charge
Nominal
Airflow
Rack
Height
Dimensions
Weight
5 A
→∞
8.4 lb
(R410A)
1,200 CFM
42U
78.5 x 23.63 x 43 in.
700 lb
Regulatory
Compliance
UL 484 (ETL),
FCC A, RoHS
Warranty
1 Year
Model
SNMPWEBCARD
Description
Adds Ethernet network interface for remote monitoring and control via SNMP, Web, SSH or telnet. Replaces pre-installed Modbus interface.
ENVIROSENSE
WEXT3-SRCOOL33K
Environmental sensor connects to SNMPWEBCARD for additional remote temperature/humidity monitoring. Also monitors and controls devices that support
dry contact communications. Can monitor up to 3 additional sensors.
3-year extended warranty for SRCOOL33K. (Adds 2 additional years to standard 1-year warranty.)
WEXT4-SRCOOL33K
4-year extended warranty for SRCOOL33K. (Adds 3 additional years to standard 1-year warranty.)
WEXT5-SRCOOL33K
5-year extended warranty for SRCOOL33K. (Adds 4 additional years to standard 1-year warranty.)
Learn more at www.tripplite.com/cooling
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
1111 W. 35th Street, Chicago, IL 60609 • 773.869.1234 • www.tripplite.com
201206087 95-3347