VO-LED Job Name SERIES Catalog Number Type Notes L E D V O Y A G E R Units with emergency battery are U.L. listed as emergency lighting and power equipment (U.L.-924) when equipped with specific optional battery back-up and meet requirements of the life safety code/NFPA101, NEC/OSHA and most state and local codes. Occu-smart bi-level LED lighting complies with ashrae 90.1-2010 and meets the requirements of NYC Local law 47 *Units must be correctly adjusted to provide required minimum light levels (5000K LED units will charge most photoluminescent tape products) f e a t u r e s ■ ■ ■ ■ A unique bi-level LED luminaire controlled by an integral ultra-sonic motion sensor, designed to provide safe, dependable illumination while conserving energy. Suitable for ceiling or wall mounting Bi-level fixtures operate at a low standby light level, offering safety and security with full light output instantly upon occupancy with areas fully lit only as needed Ideal for stairwells, restrooms, laundry rooms and other areas where maximum light levels are not required on a constant basis For safety and compliance purposes in areas designated as emergency egress, we recommend choosing a standby light level that will provide minimum code compliant light levels while in the standby mode. In most municipalities, this is 1 FC average See back for options finish ■ Painted with a lighting grade baked white enamel, having a reflectance factor exceeding 87% for premium quality and durability RRU-2 emergency shunt relay (see options on back) construction ■ ■ ■ ■ ■ Housings are die-formed of code gauge steel Quality construction throughout for long-term dependable service Ends are die formed for a clean, smooth look Ample knockouts are provided for convenient mounting with recessed or surface power feeds Meets ADA requirements for wall mounting diffuser ■ ■ One-piece extruded frosted linear ribbed acrylic is standard - see back for options ■ ■ ■ ■ ■ ■ Grooved formation on the edges allow for a tight, no light leak attachment to the body ■ High quality LED light engines from leading manufacturers are used in all LaMar LED fixtures - see chart on back for energy and lumen chart ■ LED ■ electrical R Due to the rapid advancements in LED technology, please consult our website for the most current technical data. All fixtures are U.L. listed and IBEW union made Universal voltage 120-277V sensor Emergency backup units available with UL 924 listing (emergency lighting and power equipment) and require specific LED components see ordering code High frequency, extremely sensitive ultra-sonic, internally mounted LED status indicator light Fail-safe feature switches light level to high (100%) if sensor is physically damaged 5 minute walk-test feature, easy-set time and sensitivity controls, compact design Time delay adjustable to 5, 10, 15 or 30 minutes warranty ■ 5 years - part replacement only (Please see our Terms & Conditions page at www.lamarlighting.com for details) Revised 7/16 Occu-smart is a registered trademark of LaMar Lighting Co., Inc. LaMar Lighting assumes no responsibility for misapplication of fixtures ■ All electrical components are U.L. listed or recognized DE IN THE MA USA V OS E- RL ED IES ordering g u i d e LED VOYAGER VOL SERIES SIZE VOL 24 - 2’ 48 - 4’ 72 - 6’ 96 - 8’ POWER L - Low M - Medium H - High LENS OPTIONS STANDBY OPTIONS FA - Frosted acrylic (std) PF - Perforated metal - white COLOR TEMP FO - Full on/off operation AS - User selectable standby options 5, 10 & 30% nominal light output GENERAL OPTIONS 30 - 3000K 35 - 3500K 40 - 4000K 50 - 5000K EM - Emergency pack, >90 min., >500 lumens EM9 - Emergency pack, UL 924 approved >90 min., >1000 lumens RRU21 - 120V emergency shunt relay (must specify) RRU27 - 277V emergency shunt relay (must specify) Consult factory for additional options not shown or listed AS - Adjustable standby models are DesignLights Consortium® qualified dimensional data NOTE: SPECIFICATIONS AND DIMENSIONAL DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE BEFORE INSTALLATION, PLEASE CONSULT YOUR LOCAL ORDINANCES AND BUILDING CODES FOR COMPLIANCE cross sections Fixtures with high frequency or ultra-sonic sensors should be rigedly mounted in wind prone areas 3.99 2” 2” 0.25” 4 MODEL 48” Note for glow in the dark exit signs, tapes and other similar products: many phosphorescent materials may not properly charge under LED light. It is the responsibility of the end user to determine suitability of the product for their specific application 1.125” 24” .875 KO 3.5” .960 K.O. MOUSE HOLE TYP 7.8” 4X 0.25” 36” 6” LED Wattage Chart (5000K) 2’ (1 Board) AS 4’ (2 Boards) AS 8" 6” Calculated TM-21 0.25” Low (L) Medium (M) - Std High (H) 15W - 1627 lu . 23W - 2552 lu 28.5W - 2871 lu 3W/4W/5W 4W/5W/8W 5W/6W/9W 24.5W - 3138 lu 43W - 5018 lu 55W - 5978 lu 6W/8W/10W 8W/10W/16W 10W/12W/18W ** AS versions shown as 5%, 10% and 40% dim 2’ 4’ Projected Reported Projected Reported Low Output 168,000 Hrs > 60,000 Hrs 168,000 Hrs > 60,000 Hrs Med Output 168,000 Hrs > 60,000 Hrs 168,000 Hrs > 60,000 Hrs High Output 134,000 Hrs > 60,000 Hrs 146,000 Hrs > 60,000 Hrs The UL924 listed RRU-2 emergency shunt relay allows emergency luminaires controlled by a 0-10V driver or ballast to be automatically illuminated to full brightness during a utility power failure or room power interruption. This requires the luminaire to be connected to a generator or invertor protected circuit and the control module to be connected to a standard ‘always on’ circuit. LaMar Lighting assumes no responsibility for misapplication of fixtures Due to the rapid advancements in LED technology, please consult our website for the most current technical data. LAMAR LIGHTING 485 Smith Street, Farmingdale, NY 11735 L70C 25 C Ambient Revised 7/16 • Tel (631) 777-7700 Fax (631) 777-7705 • Outside NY (800) 724-7743 • www.lamarlighting.com R Scan QR code to be directed to our home page! Protected by one or more US Patents Nos. 7,271,543 & 7,081,715