Product Catalog NEK 606/BFOU/RFOU/BU/RU Marine, oil, gas and offshore cables Offshore Cables Basic Program IEC / NEK TS 606 Index NEK 606 Cable types ........................................................................................................................ 3 Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S5 ........................ 4 Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S6 ....................... 8 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 150/250(300)V, S3/S7 ... 12 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 150/250(300)V, S4/S8 .. 17 Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V, S11 ............ 21 Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V, S12 ........... 24 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i) 150/250(300)V, S13 ........................................................................................................................... 27 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c) 150/250(300)V, S14 ........................................................................................................................... 30 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8 .............................................. 33 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables ....... 40 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided ..................... 42 Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P9 ....................................... 44 Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P10 ....................................... 47 Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P11 ................................. 50 Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P21 ................................... 53 Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P22 ................................... 56 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 ...................... 58 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided ............................................................................................................................................... 66 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, large single core cables .............................................................................................................................. 69 Halogen-free, mud resistant insulated conductor UX 1000V, P15 .................................................... 71 Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV, P17 ........... 74 Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P18 ................................ 79 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with flexible conductors class 5 and separate earth cores .................................................................................... 85 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with stranded conductors class 2 and tinned copper wire braid as earth ................................................................. 88 Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F1 ................................................................... 91 Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5) ............................. 93 Flame retardant optical fibre cable, AICI-I/O/RM-W, F6 .................................................................... 95 Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED ..................................... 97 Optical fibre data sheet ...................................................................................................................... 99 ICS IE ToughCat 5e S/FTP Installation cable for tougher environments ........................................... 100 ICS IE ToughCat 7 S/FTP Installation cable for tougher environments ............................................. 102 ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments ......................................... 104 ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments ................. 106 ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments ................... 108 ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments ............... 110 ARCTIC GRADE instrumentation cable RFOU(i) 150/250(300)V, S1/S5 ........................................ 112 ARCTIC GRADE instrumentation cable RFOU(c) 150/250(300)V, S2/S6 ....................................... 116 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(i) 150/250(300)V, S3/S7 .................. 119 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(c) 150/250(300)V, S4/S8 ................. 123 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8 ................................................................ 127 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables ........................ 133 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided ...................................... 135 Subject to change without prior notice Page 1 of 212 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 ...................................... 137 ARCTIC double braided ............ 143 ARCTIC GRADE GRADE Fire Fire resistant resistant power power cable, cable, BFOU BFOU 0,6/1(1,2)kV, 0,6/1(1,2)kV, P5/P12, P5/P12 ...................................... 137 eXtended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V ................................. 145 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided ............ 143 eXtended Fire Resistant, instrumentation cable BFOU-XFR(c) 150/250(300)V ................................ 150 eXtended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V ................................. 145 eXtended steel wire braided ... 150 155 eXtended Fire Fire Resistant, Resistant, instrumentation instrumentation cable cable BFCU-XFR(i) BFOU-XFR(c)150/250(300)V, 150/250(300)V ................................ eXtended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire braided .. eXtended Fire Resistant, instrumentation cable BFCU-XFR(i) 150/250(300)V, steel wire braided ... 160 155 Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V ........................ 165 eXtended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire braided .. 160 Hydraulic and Turbine oils resistant, instrumentation cable BFOV(c) 150/250(300)V ....................... 167 Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V ........................ 165 Hydraulic cable BFOV 0,6/1(1,2)kV .............................................. Hydraulic and and Turbine Turbine oils oils resistant, resistant, power instrumentation cable BFOV(c) 150/250(300)V ....................... 170 167 Hydro Carbon Fire Resistant Cables ................................................................................................. 173 Hydraulic and Turbine oils resistant, power cable BFOV 0,6/1(1,2)kV .............................................. 170 Hydro Fire Resistant resistant instrument cable BFOU-HCF(i) 150/250(300)V, S15 ........................... 176 Hydro Carbon Carbon Fire Cables ................................................................................................. 173 Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S16 .......................... 179 Hydro Carbon Fire resistant instrument cable BFOU-HCF(i) 150/250(300)V, S15 ........................... 176 Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P34 .......................................... 181 Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S16 .......................... 179 Hydro Carbon Fire resistant MV power cable RFOU-HCF 6/10(12)kV, P30 ..................................... 186 Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P34 .......................................... 181 Hydro ............................... 189 Hydro Carbon Carbon Fire Fire resistant resistant MV MV power power cable cable RFOU-HCF RFOU-HCF 8,7/15(17,5)kV, 6/10(12)kV, P30P31 ..................................... 186 Approvals ........................................................................................................................................... 191 Hydro Carbon Fire resistant MV power cable RFOU-HCF 8,7/15(17,5)kV, P31 ............................... 189 Standards and tests ........................................................................................................................... Approvals ........................................................................................................................................... 192 191 Definition of terms .............................................................................................................................. Standards and tests ........................................................................................................................... 194 192 Fire, flame, smoke and corrosion test methods ................................................................................. 195 Definition of terms .............................................................................................................................. 194 Installation recommendations ............................................................................................................ 197 Fire, flame, smoke and corrosion test methods ................................................................................. 195 Electrical .................................................................................................................................... Installationdata recommendations ............................................................................................................ 198 197 Material properties ............................................................................................................................. 207 Electrical data .................................................................................................................................... 198 SHF1 versus SHF2 ............................................................................................................................ 209 Material properties ............................................................................................................................. 207 Core colours for cables according to NEK TS 606 ............................................................................ 210 SHF1 versus SHF2 ............................................................................................................................ 209 Drum capacityforincables metersaccording .................................................................................................................... 211 Core colours to NEK TS 606 ............................................................................ 210 Code for cables .............................................................................................................. 212 Drum designation capacity in meters .................................................................................................................... 211 Code designation for cables .............................................................................................................. 212 Subject to change without prior notice Page 2 of 212 Subject to change without prior notice Page 2 of 212 NEK 606 Cable types List of all the cable types listed in NEK 606 : NEK 2004 Third Edition NEK TS 606 Code NEK TS 606 Description Draka Norsk Kabel’s cable type Power cables LV and MV P1 P1 / P8 P2 P2 / P9 P3 P3/P10 P4 P4/P11 P5 P5/P12 P6 P6/P13 P7 P7/P14 P15 P16 P17 P18 P19 P19/P21 P20 P20/P22 P30 P31 P32 P33 P34 RFOU / TFOU 0,6/1 kV RFOU / TFOU 3,6/6(7,2) kV RFOU / TFOU 6/10(12) kV RFOU / TFOU 8,7/15(17,5) kV BFOU 0,6/1 kV BFOU 3,6/6(7,2) kV BFOU 6/10(12) kV UX 0,6/1 kV IFLI 250V BU 0,6/1 kV RU 0,6/1 kV RFOU / TFOU 12/20(24) kV RFOU / TFOU 18/30(36) kV RFOU-HCF / TFOU-HCF 6/10(12) kV RFOU-HCF / TFOU-HCF 8,7/15(17,5) kV RFOU-HCF / TFOU-HCF 12/20(24) kV RFOU-HCF / TFOU-HCF 18/30(36) kV BFOU-HCF 0,6/1 kV RFOU 0,6/1 kV RFOU 3,676(7,2) kV RFOU 6/10(12) kV RFOU 8,7/15(17,5) kV BFOU 0,6/1 kV UX 0,6/1 kV IFLI 250V BU 0,6/1 kV RU 0,6/1 kV RFOU 12/20(24) kV RFOU 18/30(36) kV RFOU-HCF 6/10(12) kV RFOU-HCF 8,7/15(17,5) kV RFOU-HCF 12/20(24) kV RFOU-HCF 18/30(36) kV BFOU-HCF 0,6/1 kV Instrumentation and telecommunication cables S1 S1/S5 S2 S2/S6 S3 S3/S7 S4 S4/S8 S9 S10 S11 S12 S13 S14 S15 S16 RFOU(i) 250V RFOU(c) 250V BFOU(i) 250V BFOU(c) 250V IYXI(c) 60V IYOI(c) 60V RU(i) 250V RU(c) 250V BU(i) 250V BU(c) 250V BFOU-HCF(i) 250V BFOU-HCF(c) 250V RFOU(i) 250V RFOU(c) 250V BFOU(i) 250V BFOU(c) 250V RU(i) 250V RU(c) 250V BU(i) 250V BU(c) 250V BFOU-HCF(i) 250V BFOU-HCF(c) 250V QFCI QFCI-HCF QFCB AICI QFCI QFCI-HCF QFCI- MUD AICI Optical Fibre Cable F1 F4 F5 F6 Cable types P8 – P14, P21 – P22, S5 – S8 and F5 are to be mud resistant as per NEK TS 606 Subject to change without prior notice Page 3 of 212 Halogen-free, mud resistant instrumentation cable RFOU(i) 150/250(300)V, S1/S5 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, Control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas. Meets the mud resistant requirements in NEK TS 606:2009. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 mm2 IEC 60092376 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 4 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Diameter inner covering, mm 1 1 2 2 2 2 2 2 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 4 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 12 2 0.75 1.1 0.6 1.4 12 2 0.75 1.1 0.6 1.4 16 16 19 19 2 2 2 2 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 1.9 1.9 1.9 1.9 7 ± 0.5 7 ± 0.5 10 ± 0.8 10 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 21.5 ± 1 21.5 ± 1 22.5 ± 1 22.5 ± 1 24 2 0.75 1.1 0.6 2.1 24 2 0.75 1.1 0.6 1 3 0.75 1.1 1 3 0.75 2 3 2 Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 0.2 0.2 0.2 0.2 3.8 3.8 5.3 5.3 1.1 1.1 1.2 1.2 10 ± 0.8 10 ± 0.8 13 ± 0.8 13 ± 0.8 185 185 275 275 54 54 85 85 0.3 10.2 1.3 15 ± 0.8 430 166 0.3 10.2 1.3 15 ± 0.8 430 166 690 265 690 265 19.5 ± 0.8 19.5 ± 0.8 0.3 13.6 1.5 0.3 13.6 1.5 0.3 15.3 1.6 23 ± 1 940 348 0.3 15.3 1.6 23 ± 1 940 348 0.3 0.3 0.3 0.3 17.8 17.8 17.8 17.8 1.7 1.7 1.7 1.7 1240 1240 1360 1360 439 439 489 489 26.5 ± 1 0.3 20.4 1.9 1720 596 2.1 26.5 ± 1 0.3 20.4 1.9 26 ± 1 26 ± 1 27 ± 1 27 ± 1 31.5 ± 1.5 31.5 ± 1.5 1720 596 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 200 60 1.1 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 200 60 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 8.5 1.3 360 130 3 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 8.5 1.3 360 130 4 3 0.75 1.1 0.6 1.1 0.3 10.2 1.4 510 192 4 3 0.75 1.1 0.6 1.1 8 8 12 12 16 16 19 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.4 1.4 2.1 2.1 2.1 24 3 0.75 1.1 0.6 2.5 24 3 0.75 1.1 0.6 2.5 1 1 2 2 1.5 1.5 1.6 1.6 0.7 0.7 2 2 1.5 1.6 2 2 1.5 4 4 8 8 12 12 2 2 2 2 2 2 16 2 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 21 ± 1 21 ± 1 24.5 ± 1 24.5 ± 1 25.5 ± 1 30.5 ± 1.5 30.5 ± 1.5 0.3 10.2 1.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 13.6 13.6 17.8 17.8 17.8 17.8 20.4 1.5 1.5 1.7 1.7 1.8 1.8 1.8 10.5 ± 0.8 10.5 ± 0.8 14.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 21.5 ± 1 21.5 ± 1 25.5 ± 1 25.5 ± 1 29.5 ± 1 29.5 ± 1 30 ± 1.5 0.3 22.9 2 36 ± 1.5 2240 776 0.3 22.9 2 36 ± 1.5 2240 776 1.1 1.1 8 ± 0.5 8 ± 0.5 0.2 0.2 3.8 3.8 1.1 1.1 230 230 71 71 0.7 1.1 12 ± 0.8 0.3 10.2 1.3 420 168 1.6 0.7 1.1 12 ± 0.8 0.3 10.2 1.3 420 168 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.4 1.4 14 ± 0.8 14 ± 0.8 19 ± 0.8 19 ± 0.8 23 ± 1 23 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 11.9 11.9 15.3 15.3 17.8 17.8 1.4 1.4 1.6 1.6 1.8 1.8 600 600 980 980 1380 1380 252 252 420 420 580 580 1.5 1.6 0.7 1.9 26.5 ± 1 0.3 20.4 1.9 11 ± 0.8 11 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 18 ± 0.8 18 ± 0.8 23.5 ± 1 23.5 ± 1 28 ± 1 28 ± 1 31.5 ± 1.5 1830 740 Subject to change without prior notice 510 192 800 800 1160 1160 1540 1540 1720 317 317 450 450 542 542 636 Page 5 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm 16 2 1.5 1.6 0.7 1.9 26.5 ± 1 0.3 20.4 1.9 19 2 1.5 1.6 0.7 1.9 27.5 ± 1 0.3 22.9 1.9 19 2 1.5 1.6 0.7 1.9 27.5 ± 1 0.3 22.9 1.9 24 24 32 2 2 2 1.5 1.5 1.5 1.6 1.6 1.6 0.7 0.7 0.7 2.3 2.3 2.4 33 ± 1.5 33 ± 1.5 37 ± 1.5 0.4 0.4 0.4 36.2 36.2 40.7 2.2 2.2 2.3 1 3 1.5 1.6 0.7 1.1 8.5 ± 0.5 0.2 4.5 1.1 1 3 1.5 1.6 0.7 1.1 8.5 ± 0.5 0.2 4.5 1.1 2 3 1.5 1.6 0.7 1.1 0.3 11.9 1.4 4 3 1.5 1.6 0.7 1.1 0.3 13.6 1.5 4 3 1.5 1.6 0.7 1.1 8 8 12 12 16 16 24 24 3 3 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.4 1.4 2.3 2.3 2.5 2.5 1 2 2.5 2 0.7 1.1 2 2 2.5 2 0.7 1.1 2 2 2.5 2 0.7 1.1 4 2 2.5 2 0.7 1.1 13.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 21.5 ± 1 21.5 ± 1 26 ± 1 26 ± 1 31 ± 1.5 31 ± 1.5 38 ± 1.5 38 ± 1.5 9 ± 0.5 13.5 ± 0.8 13.5 ± 0.8 16 ± 0.8 Diameter outer sheath, mm 31.5 ± 1.5 32.5 ± 1.5 32.5 ± 1.5 39 ± 1.5 39 ± 1.5 43 ± 2 11.5 ± 0.8 11.5 ± 0.8 17.5 ± 0.8 20 ± 1 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1830 740 2040 866 2040 866 2790 2790 3440 1165 1165 1480 260 93 260 93 510 212 740 325 0.3 13.6 1.5 20 ± 1 740 325 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 17.8 17.8 20.4 20.4 22.9 22.9 40.7 40.7 1.7 1.7 1.9 1.9 2 2 2.3 2.3 26 ± 1 26 ± 1 31 ± 1.5 31 ± 1.5 36 ± 1.5 36 ± 1.5 44 ± 2 44 ± 2 1230 1230 1740 1740 2420 2420 3570 3570 557 557 774 774 990 990 1547 1547 0.2 4.5 1.1 280 99 0.3 11.9 1.4 530 225 0.3 11.9 1.4 530 225 0.3 13.6 1.5 12 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 20 ± 1 770 350 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² 110 110 0,67 0,67 26,3 26,3 12,7 12,7 Shielded pair 1,5 mm² Shielded triple 1,5 mm² 125 125 0,63 0,63 12,9 12,9 24,4 24,4 Shielded pair 2,5 mm² Shielded triple 2,5 mm² 145 145 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 20110590 20105042 20110591 20110592 20110593 20110849 20110594 20104951 20110850 20131006 892042 892043 892045 892046 20110595 892049 Description RFOU(I) 1PAIR 0.75mm² S1/S5 RFOU(I) 1PAIR 0.75mm² S1/S5 RFOU(I) 2PAIR 0.75mm² S1/S5 RFOU(I) 2PAIR 0.75mm² S1/S5 RFOU(I) 4PAIR 0.75mm² S1/S5 RFOU(I) 4PAIR 0.75mm² S1/S5 RFOU(I) 8PAIR 0.75mm² S1/S5 RFOU(I) 8PAIR 0.75mm² S1/S5 RFOU(I) 12PAIR 0.75mm² S1/S5 RFOU(I) 12PAIR 0.75mm² S1/S5 RFOU(I) 16PAIR 0.75mm² S1/S5 RFOU(I) 16PAIR 0.75mm² S1/S5 RFOU(I) 19PAIR 0.75mm² S1/S5 RFOU(I) 19PAIR 0.75mm² S1/S5 RFOU(I) 24PAIR 0.75mm² S1/S5 RFOU(I) 24PAIR 0.75mm² S1/S5 Subject to change without prior notice Sheath Colour GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Stock item Yes Yes Yes Yes Yes - EAN No. DNK 7021528920000 7021528920017 7021528920062 7021528920079 7021528920185 7021528920192 7021528920307 7021528920314 7021528920369 7021528920376 7021528920420 7021528920437 7021528920451 7021528920468 7021528920482 7021528920499 EL No. 1044620 1044619 1044621 1044622 1044623 1044624 1044628 1044629 1044630 1044631 1044633 1044632 1044634 1044635 1044636 1044637 Page 6 of 212 New Part number Old Part number 20104949 20110596 20110851 892067 20110852 892079 892090 892091 892096 892097 892102 892103 892106 892108 892109 20110597 20110598 20110599 20111211 20110600 20110601 20110602 20110603 20110604 20110605 20110606 20110607 892245 892246 892248 20110853 892254 20110608 20110609 892266 892278 892279 20110610 892291 892296 892297 892302 892303 892308 892309 20110854 20110855 892407 20110856 Description Sheath Colour Stock item EAN No. DNK EL No. RFOU(I) 1TRIP 0.75mm² S1/S5 RFOU(I) 1TRIP 0.75mm² S1/S5 RFOU(I) 2TRIP 0.75mm² S1/S5 RFOU(I) 2TRIP 0.75mm² S1/S5 RFOU(I) 4TRIP 0.75mm² S1/S5 RFOU(I) 4TRIP 0.75mm² S1/S5 RFOU(I) 8TRIP 0.75mm² S1/S5 RFOU(I) 8TRIP 0.75mm² S1/S5 RFOU(I) 12TRIP 0.75mm² S1/S5 RFOU(I) 12TRIP 0.75mm² S1/S5 RFOU(I) 16TRIP 0.75mm² S1/S5 RFOU(I) 16TRIP 0.75mm² S1/S5 RFOU(I) 19TRIP 0.75mm² S1/S5 RFOU(I) 24TRIP 0.75mm² S1/S5 RFOU(I) 24TRIP 0.75mm² S1/S5 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE Yes - 7021528920604 7021528920611 7021528920666 7021528920673 7021528920789 7021528920796 7021528920901 7021528920918 7021528920963 7021528920970 7021528921021 7021528921038 7021528921069 7021528921083 7021528921090 1044690 1044689 1044691 1044692 1044693 1044694 1044697 1044698 1044699 1044700 1044701 1044702 1044707 1044708 RFOU(I) 1PAIR 1.5mm² S1/S5 RFOU(I) 1PAIR 1.5mm² S1/S5 RFOU(I) 2PAIR 1.5mm² S1/S5 RFOU(I) 2PAIR 1.5mm² S1/S5 RFOU(I) 4PAIR 1.5mm² S1/S5 RFOU(I) 4PAIR 1.5mm² S1/S5 RFOU(I) 8PAIR 1.5mm² S1/S5 RFOU(I) 8PAIR 1.5mm² S1/S5 RFOU(I) 12PAIR 1.5mm² S1/S5 RFOU(I) 12PAIR 1.5mm² S1/S5 RFOU(I) 16PAIR 1.5mm² S1/S5 RFOU(I) 16PAIR 1.5mm² S1/S5 RFOU(I) 19PAIR 1.5mm² S1/S5 RFOU(I) 19PAIR 1.5mm² S1/S5 RFOU(I) 24PAIR 1.5mm² S1/S5 RFOU(I) 24PAIR 1.5mm² S1/S5 RFOU(I) 32PAIR 1.5mm² S1/S5 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY Yes Yes Yes Yes Yes Yes Yes Yes - 7021528922004 7021528922011 7021528922066 7021528922073 7021528922189 7021528922196 7021528922301 7021528922318 7021528922363 7021528922370 7021528922424 7021528922431 7021528922455 7021528922462 7021528922486 7021528922493 7021528922547 1044460 1044459 1044661 1044662 1044663 1044664 1044668 1044669 1044670 1044671 1044673 1044672 1044674 1044675 1044678 1044679 - RFOU(I) 1TRIP 1.5mm² S1/S5 RFOU(I) 1TRIP 1.5mm² S1/S5 RFOU(I) 2TRIP 1.5mm² S1/S5 RFOU(I) 4TRIP 1.5mm² S1/S5 RFOU(I) 4TRIP 1.5mm² S1/S5 RFOU(I) 8TRIP 1.5mm² S1/S5 RFOU(I) 8TRIP 1.5mm² S1/S5 RFOU(I) 12TRIP 1.5mm² S1/S5 RFOU(I) 12TRIP 1.5mm² S1/S5 RFOU(I) 16TRIP 1.5mm² S1/S5 RFOU(I) 16TRIP 1.5mm² S1/S5 RFOU(I) 24TRIP 1.5mm² S1/S5 RFOU(I) 24TRIP 1.5mm² S1/S5 GREY BLUE GREY GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528922608 7021528922615 7021528922660 7021528922783 7021528922790 7021528922905 7021528922912 7021528922967 7021528922974 7021528923025 7021528923032 7021528923087 7021528923094 1044560 1044559 1044762 1044764 1044765 1044768 1044769 1044770 1044771 1044773 1044772 1044779 1044780 RFOU(I) 1PAIR 2.5mm² S1/S5 RFOU(I) 2PAIR 2.5mm² S1/S5 RFOU(I) 2PAIR 2.5mm² S1/S5 RFOU(I) 4PAIR 2.5mm² S1/S5 GREY GREY BLUE GREY - 7021528924008 7021528924060 7021528924077 7021528924183 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 7 of 212 Halogen-free, mud resistant instrumentation cable RFOU(c) 150/250(300)V, S2/S6 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(c) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS2/S6 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, IEC 60092-360 communication, Control and alarm systems in both IEC 60092-360 EX (Zone 0, 1 & 2)- and safe areas. Meets the mud IEC 60332-1-2 resistant requirements in NEK TS 606:2009. IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 mm2 IEC 60092376 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 8 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 2 2 2 0.75 0.75 1.1 1.1 0.6 0.6 1.1 1.1 4 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 8 8 12 12 16 16 19 24 24 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.4 1.4 1.9 1.9 1.9 2.1 2.1 2 2 3 3 0.75 0.75 1.1 1.1 0.6 0.6 1.1 1.1 4 3 0.75 1.1 0.6 1.1 4 3 0.75 1.1 0.6 1.1 8 8 12 12 16 24 24 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 2 2 1.5 1.6 2 2 1.5 4 4 2 2 8 2 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 10 ± 0.8 10 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 15 ± 0.8 15 ± 0.8 18 ± 0.8 18 ± 0.8 20.5 ± 1 20.5 ± 1 21.5 ± 1 25 ± 1 25 ± 1 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 0.2 0.2 5.3 5.3 1.2 1.2 13 ± 0.8 13 ± 0.8 270 270 81 81 0.3 8.5 1.3 15 ± 0.8 390 138 0.3 8.5 1.3 15 ± 0.8 390 139 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 11.9 11.9 15.3 15.3 15.3 15.3 17.8 20.4 20.4 1.4 1.4 1.5 1.5 1.6 1.6 1.6 1.8 1.8 19 ± 0.8 19 ± 0.8 22 ± 1 22 ± 1 24.5 ± 1 24.5 ± 1 25.5 ± 1 29.5 ± 1 29.5 ± 1 600 600 820 820 1040 1040 1160 1450 1450 223 223 307 307 358 358 422 510 510 0.2 0.2 5.3 5.3 1.2 1.2 310 310 94 94 0.3 10.2 1.3 14 ± 0.8 14 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 21 ± 1 21 ± 1 24.5 ± 1 24.5 ± 1 27.5 ± 1 33 ± 1.5 33 ± 1.5 470 181 0.3 10.2 1.3 1.1 1.1 1.4 1.4 2.1 2.3 2.3 11 ± 0.8 11 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 20 ± 1 20 ± 1 23 ± 1 28 ± 1 28 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 13.6 13.6 15.3 15.3 17.8 20.4 20.4 1.5 1.5 1.6 1.6 1.7 1.9 1.9 0.7 1.1 12 ± 0.8 0.3 10.2 1.3 1.6 0.7 1.1 12 ± 0.8 0.3 10.2 1.3 1.5 1.5 1.6 1.6 0.7 0.7 1.1 1.1 0.3 0.3 11.9 11.9 1.5 1.6 0.7 1.1 0.3 15.3 0.3 15.3 1.6 23 ± 1 890 379 0.3 0.3 0.3 0.3 0.3 0.3 0.3 17.8 17.8 17.8 17.8 20.4 20.4 20.4 1.7 1.7 1.7 1.7 1.8 1.8 1.9 25.5 ± 1 25.5 ± 1 26.5 ± 1 26.5 ± 1 29.5 ± 1 29.5 ± 1 31 ± 1.5 36.5 ± 1.5 40 ± 2 40 ± 2 1070 1070 1210 1210 1580 1580 1750 459 459 515 515 651 651 735 2270 924 2890 2890 1252 1252 17 ± 0.8 17 ± 0.8 19.5 ± 0.8 25.5 ± 1 29.5 ± 1 29.5 ± 1 33 ± 1.5 33 ± 1.5 41 ± 2 480 480 190 190 670 290 1130 1560 1560 2080 2080 3110 516 708 708 900 900 1365 181 291 291 384 384 486 664 664 410 162 410 162 1.4 1.4 15.5 ± 0.8 15.5 ± 0.8 18 ± 0.8 18 ± 0.8 560 560 234 234 1.6 23 ± 1 890 379 8 2 1.5 1.6 0.7 1.1 10 10 12 12 16 16 19 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.2 1.2 1.4 1.4 1.9 1.9 1.9 14 ± 0.8 14 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 21 ± 1 21 ± 1 22 ± 1 22 ± 1 25 ± 1 25 ± 1 26.5 ± 1 24 2 1.5 1.6 0.7 2.3 31 ± 1.5 0.3 25.4 2.1 32 32 2 2 1.5 1.5 1.6 1.6 0.7 0.7 2.4 2.4 34 ± 1.5 34 ± 1.5 0.4 0.4 36.2 36.2 2.2 2.2 2 2 3 3 1.5 1.5 1.6 1.6 0.7 0.7 1.1 1.1 0.3 0.3 10.2 10.2 1.4 1.4 4 3 1.5 1.6 0.7 1.1 0.3 11.9 1.4 8 12 12 16 16 24 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.4 1.4 2.1 2.1 2.5 13 ± 0.8 13 ± 0.8 15.5 ± 0.8 21 ± 1 24.5 ± 1 24.5 ± 1 28 ± 1 28 ± 1 35 ± 1.5 0.3 0.3 0.3 0.3 0.3 0.4 17.8 20.4 20.4 22.9 22.9 36.2 1.7 1.8 1.8 1.9 1.9 2.2 Subject to change without prior notice 470 740 740 1010 1010 1350 1860 1860 Page 9 of 212 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 35 ± 1.5 0.4 36.2 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 24 3 1.5 1.6 0.7 2.5 2.2 41 ± 2 3110 1365 2 2 2.5 2 0.7 1.1 13.5 ± 0.8 0.3 10.2 1.4 490 200 4 2 2.5 2 0.7 1.1 16 ± 0.8 0.3 11.9 1.4 680 309 4 2 2.5 2 0.7 1.1 16 ± 0.8 0.3 11.9 1.4 680 309 12 2 2.5 2 0.7 2.1 27 ± 1 0.3 20.4 1.8 1740 759 17.5 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 31.5 ± 1.5 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 20110611 20110857 20110612 20110613 20110614 20110772 20110615 892637 20109493 892643 892645 20109494 892649 20110858 20110616 20110859 892679 20120514 892691 892696 892697 892702 892708 892709 20110617 20110618 20110619 20110620 20110621 892831 892834 892835 20110622 892837 20109495 892843 892845 20110860 892854 Description Sheath Colour Stock item EAN No. DNK EL No. RFOU(C) 2PAIR 0.75mm² S2/S6 RFOU(C) 2PAIR 0.75mm² S2/S6 RFOU(C) 4PAIR 0.75mm² S2/S6 RFOU(C) 4PAIR 0.75mm² S2/S6 RFOU(C) 8PAIR 0.75mm² S2/S6 RFOU(C) 8PAIR 0.75mm² S2/S6 RFOU(C) 12PAIR 0.75mm² S2/S6 RFOU(C) 12PAIR 0.75mm² S2/S6 RFOU(C) 16PAIR 0.75mm² S2/S6 RFOU(C) 16PAIR 0.75mm² S2/S6 RFOU(C) 19PAIR 0.75mm² S2/S6 RFOU(C) 24PAIR 0.75mm² S2/S6 RFOU(C) 24PAIR 0.75mm² S2/S6 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE Yes Yes - 7021528926064 7021528926071 7021528926187 7021528926194 7021528926309 7021528926316 7021528926361 7021528926378 7021528926422 7021528926439 7021528926453 7021528926484 7021528926491 1044421 1044422 1044423 1044424 1044428 1044429 1044430 1044431 1044433 1044432 1044434 1044438 1044437 RFOU(C) 2TRIP 0.75mm² S2/S6 RFOU(C) 2TRIP 0.75mm² S2/S6 RFOU(C) 4TRIP 0.75mm² S2/S6 RFOU(C) 4TRIP 0.75mm² S2/S6 RFOU(C) 8TRIP 0.75mm² S2/S6 RFOU(C) 8TRIP 0.75mm² S2/S6 RFOU(C) 12TRIP 0.75mm² S2/S6 RFOU(C) 12TRIP 0.75mm² S2/S6 RFOU(C) 16TRIP 0.75mm² S2/S6 RFOU(C) 24TRIP 0.75mm² S2/S6 RFOU(C) 24TRIP 0.75mm² S2/S6 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE - 7021528926668 7021528926675 7021528926781 7021528926798 7021528926903 7021528926910 7021528926965 7021528926972 7021528927023 7021528927085 7021528927092 1044490 1044491 1044492 1044493 1044496 1044497 1044499 1044500 1044501 1044507 1044508 RFOU(C) 2PAIR 1.5mm² S2/S6 RFOU(C) 2PAIR 1.5mm² S2/S6 RFOU(C) 4PAIR 1.5mm² S2/S6 RFOU(C) 4PAIR 1.5mm² S2/S6 RFOU(C) 8PAIR 1.5mm² S2/S6 RFOU(C) 8PAIR 1.5mm² S2/S6 RFOU(C) 10PAIR 1.5mm² S2/S6 RFOU(C) 10PAIR 1.5mm² S2/S6 RFOU(C) 12PAIR 1.5mm² S2/S6 RFOU(C) 12PAIR 1.5mm² S2/S6 RFOU(C) 16PAIR 1.5mm² S2/S6 RFOU(C) 16PAIR 1.5mm² S2/S6 RFOU(C) 19PAIR 1.5mm² S2/S6 RFOU(C) 24PAIR 1.5mm² S2/S6 RFOU(C) 32PAIR 1.5mm² S2/S6 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY GREY Yes Yes Yes Yes - 7021528928068 7021528928075 7021528928181 7021528928198 7021528928303 7021528928310 7021528928341 7021528928358 7021528928365 7021528928372 7021528928426 7021528928433 7021528928457 7021528928488 7021528928549 1044461 1044462 1044463 1044464 1044468 1044469 1044470 1044472 1044473 1044474 1044478 - Subject to change without prior notice Page 10 of 212 New Part number Old Part Description number 892855 RFOU(C) 32PAIR 1.5mm² S2/S6 BLUE - 7021528928556 - RFOU(C) 2TRIP 1.5mm² S2/S6 RFOU(C) 2TRIP 1.5mm² S2/S6 RFOU(C) 4TRIP 1.5mm² S2/S6 RFOU(C) 8TRIP 1.5mm² S2/S6 RFOU(C) 12TRIP 1.5mm² S2/S6 RFOU(C) 12TRIP 1.5mm² S2/S6 RFOU(C) 16TRIP 1.5mm² S2/S6 RFOU(C) 16TRIP 1.5mm² S2/S6 RFOU(C) 24TRIP 1.5mm² S2/S6 RFOU(C) 24TRIP 1.5mm² S2/S6 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528928662 7021528928679 7021528928785 7021528928914 7021528928969 7021528928976 7021528929027 7021528929034 7021528929089 7021528929096 1044561 1044563 1044568 1044569 1044570 1044571 1044572 1044577 1044578 RFOU(C) 2PAIR 2.5mm² S2/S6 RFOU(C) 4PAIR 2.5mm² S2/S6 RFOU(C) 4PAIR 2.5mm² S2/S6 RFOU(C) 12PAIR 2.5mm² S2/S6 GREY GREY BLUE GREY - 7021528930061 7021528930184 7021528930191 7021528930368 - 20110861 892867 892878 892891 892896 892897 892902 892903 892908 892909 893006 20120742 20110862 20110863 Sheath Colour Stock item EAN No. DNK EL No. Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 11 of 212 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(i) 150/250(300)V, S3/S7 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 12 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 1 4 0.75 1.1 0.6 1.1 8.5 ± 0.5 0.2 4.5 1.2 2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 10.2 1.3 2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 10.2 1.3 4 2 0.75 1.1 0.6 1.1 0.3 11.9 1.4 4 2 0.75 1.1 0.6 1.1 8 8 12 12 16 16 19 19 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 24 2 0.75 1.1 24 2 0.75 1 1 3 3 2 0.3 11.9 1.4 1.1 1.1 1.4 1.4 1.9 1.9 1.9 1.9 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 20.5 ± 1 20.5 ± 1 24 ± 1 24 ± 1 25 ± 1 25 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 15.3 15.3 17.8 17.8 20.4 20.4 20.4 20.4 1.6 1.6 1.7 1.7 1.8 1.8 1.9 1.9 0.6 2.3 30 ± 1.5 0.4 31.7 2.1 1.1 0.6 2.3 30 ± 1.5 0.4 31.7 2.1 0.75 0.75 1.1 1.1 0.6 0.6 1.1 1.1 8 ± 0.5 8 ± 0.5 0.2 0.2 4.5 4.5 1.1 1.1 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 10.2 1.4 2 3 0.75 1.1 0.6 1.1 12 ± 0.8 0.3 10.2 1.4 4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 11.9 1.4 4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 11.9 1.4 8 3 0.75 1.1 0.6 1.1 0.3 17.8 1.7 8 3 0.75 1.1 0.6 1.1 12 12 3 3 0.75 0.75 1.1 1.1 0.6 0.6 16 3 0.75 1.1 16 3 0.75 19 24 24 3 3 3 1 1 2 2 Diameter outer sheath, mm 10.5 ± 0.8 10.5 ± 0.8 12 ± 0.8 14.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 21.5 ± 1 21.5 ± 1 25 ± 1 25 ± 1 28.5 ± 1 28.5 ± 1 29.5 ± 1 29.5 ± 1 35.5 ± 1.5 35.5 ± 1.5 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 200 54 200 54 250 74 360 133 360 133 490 183 490 183 780 780 1060 1060 1400 1400 1550 1550 283 283 373 373 465 465 514 514 2100 708 2100 708 11 ± 0.8 11 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 220 220 68 68 410 146 410 146 570 209 570 209 23 ± 1 960 359 0.3 17.8 1.7 23 ± 1 960 359 1.4 1.4 18.5 ± 0.8 18.5 ± 0.8 22.5 ± 1 22.5 ± 1 0.3 0.3 20.4 20.4 1.8 1.8 1310 1310 477 477 0.6 2.1 26.5 ± 1 0.3 22.9 1.9 1770 594 1.1 0.6 2.1 26.5 ± 1 0.3 22.9 1.9 1770 594 0.75 0.75 0.75 1.1 1.1 1.1 0.6 0.6 0.6 2.3 2.5 2.5 28 ± 1 33 ± 1.5 33 ± 1.5 0.3 0.4 0.4 22.9 36.2 36.2 2 2.2 2.2 27.5 ± 1 27.5 ± 1 31.5 ± 1.5 31.5 ± 1.5 33 ± 1.5 39 ± 1.5 39 ± 1.5 2000 2630 2630 663 909 909 2 2 2 2 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 0.2 0.2 0.3 0.3 4.5 4.5 11.9 11.9 1.2 1.2 1.4 1.4 79 79 184 184 2 1.5 1.6 0.7 1.1 0.3 13.6 1.5 670 269 4 2 1.5 1.6 0.7 1.1 0.3 13.6 1.5 670 269 8 8 12 2 2 2 1.5 1.5 1.5 1.6 1.6 1.6 0.7 0.7 0.7 1.1 1.1 1.4 0.3 0.3 0.3 17.8 17.8 20.4 1.7 1.7 1.9 12 ± 0.8 12 ± 0.8 17 ± 0.8 17 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 25.5 ± 1 25.5 ± 1 30.5 ± 260 260 470 470 4 9 ± 0.5 9 ± 0.5 13 ± 0.8 13 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 21 ± 1 21 ± 1 25.5 ± 1 1090 1090 1530 446 446 606 Subject to change without prior notice Page 13 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm 1.5 30.5 ± 1.5 35 ± 1.5 35 ± 1.5 36.5 ± 1.5 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1530 606 2060 2060 766 766 2440 998 12 2 1.5 1.6 0.7 1.4 25.5 ± 1 0.3 20.4 1.9 16 16 2 2 1.5 1.5 1.6 1.6 0.7 0.7 2.1 2.1 30 ± 1.5 30 ± 1.5 0.3 0.3 22.9 22.9 2 2 19 2 1.5 1.6 0.7 2.1 31 ± 1.5 0.4 36.2 2.1 24 2 1.5 1.6 0.7 2.3 0.4 40.7 2.3 43 ± 2 3080 1211 24 2 1.5 1.6 0.7 2.3 0.4 40.7 2.3 43 ± 2 3080 1211 1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 0.2 4.5 1.2 290 93 1 3 1.5 1.6 0.7 1.1 9.5 ± 0.5 0.2 4.5 1.2 290 93 2 3 1.5 1.6 0.7 1.1 11.9 1.5 550 213 2 3 1.5 1.6 0.7 1.1 4 4 8 8 3 3 3 3 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 12 3 1.5 1.6 12 3 1.5 1.6 36.5 ± 1.5 36.5 ± 1.5 0.3 11.9 1.5 1.1 1.1 1.1 1.1 14.5 ± 0.8 14.5 ± 0.8 17 ± 0.8 17 ± 0.8 22.5 ± 1 22.5 ± 1 0.3 0.3 0.3 0.3 15.3 15.3 20.4 20.4 1.6 1.6 1.8 1.8 0.7 1.6 28.5 ± 1 0.3 22.9 2 0.7 1.6 28.5 ± 1 0.3 22.9 2 0.4 36.2 2.2 0.4 36.2 0.4 0.4 16 3 1.5 1.6 0.9 2.3 16 3 1.5 1.6 0.9 2.3 24 24 3 3 1.5 1.5 1.6 1.6 0.9 0.9 2.7 2.7 1 1 2 2 2.5 2.5 2 2 0.7 0.7 1.1 1.1 2 2 2.5 2 0.7 1.1 4 8 2 2 2.5 2.5 2 2 0.7 0.7 12 2 2.5 2 16 2 2.5 1 3 8 12 36.5 ± 1.5 36.5 ± 1.5 45.5 ± 2 45.5 ± 2 0.3 12.5 ± 0.8 12.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 21 ± 1 21 ± 1 27 ± 1 27 ± 1 33.5 ± 1.5 33.5 ± 1.5 550 213 820 820 1370 1370 342 342 584 584 1970 802 1970 802 42.5 ± 2 3060 1125 2.2 42.5 ± 2 3060 1125 45.2 45.2 2.5 2.5 52 ± 2.5 52 ± 2.5 4400 4400 1598 1598 0.2 0.2 4.5 4.5 1.2 1.2 13 ± 0.8 13 ± 0.8 18.5 ± 0.8 21.5 ± 1 28 ± 1 35.5 ± 1.5 300 300 99 99 560 225 830 1390 367 633 2170 874 3040 1222 350 129 1820 844 2940 1284 0.3 11.9 1.5 1.1 1.1 9.5 ± 0.5 9.5 ± 0.5 14.5 ± 0.8 17 ± 0.8 23.5 ± 1 0.3 0.3 15.3 20.4 1.6 1.8 0.7 2.3 30 ± 1.5 0.3 22.9 2 2 0.9 2.3 36.5 ± 1.5 0.4 36.2 2.2 2.5 2 0.7 1.1 10.5 ± 0.8 0.2 5.3 1.2 3 2.5 2 0.7 1.3 25.5 ± 1 0.3 22.9 2 3 2.5 2 0.7 2.6 33.5 ± 1.5 0.4 36.2 2.2 42.5 ± 2 13.5 ± 0.8 30.5 ± 1.5 39.5 ± 1.5 Electrical values instrumentation cables Type Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded pair 2,5 mm² Shielded triple 2,5 mm² Shielded 16 and 24 triple 1,5 mm² Shielded 16 pair 2,5 mm² Subject to change without prior notice Capacitance, approx. (nF/km) 110 110 125 125 145 145 105 110 Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 0,71 0,66 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 12,9 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 24,4 41,1 Page 14 of 212 Ordering information New Part number Old Part number 20110623 20110624 20110625 20110626 20104969 20110627 20110628 20109496 20110773 20110629 20110630 20110631 20110632 893245 893246 20110633 893249 20110634 20110635 20110636 20110864 20111212 20110865 20110637 20112240 20110878 893297 20110774 893303 893305 20131938 893309 20110638 20110639 20110640 20111213 20110641 20110642 20110643 20110644 20110645 20110646 20109497 20109498 893445 20109499 20109500 20110647 20110648 20110866 893467 20109501 20117428 20110649 20117424 20109502 893497 20109503 893503 893508 893509 20110650 20110867 893606 20110868 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU(I) 1PAIR 0.75mm² S3/S7 BFOU(I) 1PAIR 0.75mm² S3/S7 BFOU(I) 1QUAD 0.75mm² S3/S7 BFOU(I) 2PAIR 0.75mm² S3/S7 BFOU(I) 2PAIR 0.75mm² S3/S7 BFOU(I) 4PAIR 0.75mm² S3/S7 BFOU(I) 4PAIR 0.75mm² S3/S7 BFOU(I) 8PAIR 0.75mm² S3/S7 BFOU(I) 8PAIR 0.75mm² S3/S7 BFOU(I) 12PAIR 0.75mm² S3/S7 BFOU(I) 12PAIR 0.75mm² S3/S7 BFOU(I) 16PAIR 0.75mm² S3/S7 BFOU(I) 16PAIR 0.75mm² S3/S7 BFOU(I) 19PAIR 0.75mm² S3/S7 BFOU(I) 19PAIR 0.75mm² S3/S7 BFOU(I) 24PAIR 0.75mm² S3/S7 BFOU(I) 24PAIR 0.75mm² S3/S7 GREY BLUE GREY GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Yes Yes Yes Yes Yes Yes Yes - 7021528932003 7021528932010 7021528932034 7021528932065 7021528932072 7021528932188 7021528932195 7021528932300 7021528932317 7021528932362 7021528932379 7021528932423 7021528932430 7021528932454 7021528932461 7021528932485 7021528932492 1043820 1043819 1044020 1044019 1044021 1044022 1044028 1044029 1044030 1044031 1044033 1044034 1044036 1044037 BFOU(I) 1TRIP 0.75mm² S3/S7 BFOU(I) 1TRIP 0.75mm² S3/S7 BFOU(I) 2TRIP 0.75mm² S3/S7 BFOU(I) 2TRIP 0.75mm² S3/S7 BFOU(I) 4TRIP 0.75mm² S3/S7 BFOU(I) 4TRIP 0.75mm² S3/S7 BFOU(I) 8TRIP 0.75mm² S3/S7 BFOU(I) 8TRIP 0.75mm² S3/S7 BFOU(I) 12TRIP 0.75mm² S3/S7 BFOU(I) 12TRIP 0.75mm² S3/S7 BFOU(I) 16TRIP 0.75mm² S3/S7 BFOU(I) 16TRIP 0.75mm² S3/S7 BFOU(I) 19TRIP 0.75mm² S3/S7 BFOU(I) 24TRIP 0.75mm² S3/S7 BFOU(I) 24TRIP 0.75mm² S3/S7 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE Yes - 7021528932607 7021528932614 7021528932669 7021528932676 7021528932782 7021528932799 7021528932904 7021528932911 7021528932966 7021528932973 7021528933024 7021528933031 7021528933055 7021528933086 7021528933093 1043920 1043919 1044121 1044122 1044123 1044124 1044128 1044129 1044130 1044131 1044132 1044138 1044139 BFOU(I) 1PAIR 1.5mm² S3/S7 BFOU(I) 1PAIR 1.5mm² S3/S7 BFOU(I) 2PAIR 1.5mm² S3/S7 BFOU(I) 2PAIR 1.5mm² S3/S7 BFOU(I) 4PAIR 1.5mm² S3/S7 BFOU(I) 4PAIR 1.5mm² S3/S7 BFOU(I) 8PAIR 1.5mm² S3/S7 BFOU(I) 8PAIR 1.5mm² S3/S7 BFOU(I) 12PAIR 1.5mm² S3/S7 BFOU(I) 12PAIR 1.5mm² S3/S7 BFOU(I) 16PAIR 1.5mm² S3/S7 BFOU(I) 16PAIR 1.5mm² S3/S7 BFOU(I) 19PAIR 1.5mm² S3/S7 BFOU(I) 24PAIR 1.5mm² S3/S7 BFOU(I) 24PAIR 1.5mm² S3/S7 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE Yes Yes Yes Yes Yes Yes Yes Yes - 7021528934007 7021528934014 7021528934069 7021528934076 7021528934182 7021528934199 7021528934304 7021528934311 7021528934366 7021528934373 7021528934427 7021528934434 7021528934458 7021528934489 7021528934496 1043860 1043859 1044060 1044061 1044063 1044064 1044068 1044069 1044070 1044071 1044073 1044074 1044076 - BFOU(I) 1TRIP 1.5mm² S3/S7 BFOU(I) 1TRIP 1.5mm² S3/S7 BFOU(I) 2TRIP 1.5mm² S3/S7 BFOU(I) 2TRIP 1.5mm² S3/S7 BFOU(I) 4TRIP 1.5mm² S3/S7 BFOU(I) 4TRIP 1.5mm² S3/S7 BFOU(I) 8TRIP 1.5mm² S3/S7 BFOU(I) 8TRIP 1.5mm² S3/S7 BFOU(I) 12TRIP 1.5mm² S3/S7 BFOU(I) 12TRIP 1.5mm² S3/S7 BFOU(I) 16TRIP 1.5mm² S3/S7 BFOU(I) 16TRIP 1.5mm² S3/S7 BFOU(I) 24TRIP 1.5mm² S3/S7 BFOU(I) 24TRIP 1.5mm² S3/S7 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Yes - 7021528934601 7021528934618 7021528934663 7021528934670 7021528934786 7021528934793 7021528934908 7021528934915 7021528934960 7021528934977 7021528935028 7021528935035 7021528935080 7021528935097 1044170 1044169 1044171 1044173 1044174 1044177 1044178 1044179 1044180 1044181 1044182 1044193 1044194 BFOU(I) 1PAIR 2.5mm² S3/S7 BFOU(I) 1PAIR 2.5mm² S3/S7 BFOU(I) 2PAIR 2.5mm² S3/S7 BFOU(I) 4PAIR 2.5mm² S3/S7 GREY BLUE GREY GREY Yes - 7021528936001 7021528936018 7021528936063 7021528936186 1044140 - Subject to change without prior notice Page 15 of 212 New Part number 20109504 Old Part Description number 893630 BFOU(I) 8PAIR 2.5mm² S3/S7 893636 BFOU(I) 12PAIR 2.5mm² S3/S7 BFOU(I) 16PAIR 2.5mm² S3/S7 GREY GREY GREY - 7021528936308 7021528936360 7021528936421 - BFOU(I) 1TRIP 2.5mm² S3/S7 BFOU(I) 8TRIP 2.5mm² S3/S7 BFOU(I) 12TRIP 2.5mm² S3/S7 GREY GREY GREY - 7021528936605 7021528936902 7021528936964 - 20110869 893690 893696 Sheath Colour Stock item EAN No. DNK EL No. Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 16 of 212 Halogen-free, mud resistant, fire resistant instrumentation cable BFOU(c) 150/250(300)V, S4/S8 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(c) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS4/S8 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, communication, control and alarm systems in both IEC 60092-360 IEC 60092-360 EX (Zone 0, 1 & 2)- and safe areas, emergency IEC 60332-1-2 and critical systems where requirement for fire IEC 60332-3-22 resistance exists. Meets the mud resistant IEC 60331-1, -2, -21 requirements in NEK TS 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 17 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 2 0.75 1.1 0.6 1.1 2 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 12 2 0.75 1.1 0.6 1.4 12 2 0.75 1.1 0.6 1.4 16 16 19 2 2 2 0.75 0.75 0.75 1.1 1.1 1.1 0.6 0.6 0.6 24 2 0.75 1.1 24 2 0.75 2 3 2 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 1.9 1.9 1.9 10.5 ± 0.8 10.5 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 22 ± 1 22 ± 1 23 ± 1 0.6 2.3 1.1 0.6 0.75 1.1 3 0.75 4 4 3 3 8 Thickness Outer Sheath, mm Diameter outer sheath, mm 14.5 ± 0.8 14.5 ± 0.8 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 340 113 340 113 0.3 8.5 1.3 0.3 8.5 1.3 0.3 10.2 1.4 16 ± 0.8 440 155 0.3 10.2 1.4 16 ± 0.8 440 155 0.3 13.6 1.5 20.5 ± 1 680 240 0.3 13.6 1.5 20.5 ± 1 680 240 0.3 15.3 1.6 24 ± 1 910 307 0.3 15.3 1.6 24 ± 1 910 307 0.3 0.3 0.3 17.8 17.8 20.4 1.7 1.7 1.8 1180 1180 1330 383 383 447 27.5 ± 1 0.3 22.9 2 1700 536 2.3 27.5 ± 1 0.3 22.9 2 26.5 ± 1 26.5 ± 1 28 ± 1 32.5 ± 1.5 32.5 ± 1.5 1700 536 0.6 1.1 12 ± 0.8 0.3 10.2 1.3 400 142 1.1 0.6 1.1 12 ± 0.8 0.3 10.2 1.3 0.75 0.75 1.1 1.1 0.6 0.6 1.1 1.1 0.3 0.3 11.9 11.9 3 0.75 1.1 0.6 1.1 0.3 8 3 0.75 1.1 0.6 1.1 12 12 3 3 0.75 0.75 1.1 1.1 0.6 0.6 1.4 1.4 14 ± 0.8 14 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 22 ± 1 22 ± 1 16 3 0.75 1.1 0.6 2.1 16 3 0.75 1.1 0.6 400 142 1.4 1.4 15.5 ± 0.8 15.5 ± 0.8 18 ± 0.8 18 ± 0.8 540 540 197 197 15.3 1.6 23 ± 1 870 308 0.3 15.3 1.6 23 ± 1 870 308 0.3 0.3 17.8 17.8 1.8 1.8 1180 1180 410 410 25.5 ± 1 0.3 20.4 1.9 1580 513 2.1 25.5 ± 1 0.3 20.4 1.9 27 ± 1 27 ± 1 30.5 ± 1.5 30.5 ± 1.5 1580 513 0.4 36.2 2.1 37 ± 1.5 2350 820 440 162 24 3 0.75 1.1 0.6 2.5 31.5 ± 1.5 2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 10.2 1.4 2 2 1.5 1.6 0.7 1.1 13 ± 0.8 0.3 10.2 1.4 4 4 8 8 12 12 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.4 1.4 15 ± 0.8 15 ± 0.8 20 ± 1 20 ± 1 24 ± 1 24 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 11.9 11.9 17.8 17.8 20.4 20.4 1.4 1.4 1.7 1.7 1.8 1.8 16 2 1.5 1.6 0.7 1.9 27 ± 1 0.3 22.9 1.9 16 2 1.5 1.6 0.7 1.9 27 ± 1 0.3 22.9 1.9 0.4 36.2 2.2 0.4 36.2 2.2 0.3 11.9 1.4 24 2 1.5 1.6 0.7 2.3 24 2 1.5 1.6 0.7 2.3 2 3 1.5 1.6 0.7 1.1 Subject to change without prior notice 33.5 ± 1.5 33.5 ± 1.5 14.5 ± 16.5 ± 0.8 16.5 ± 0.8 19 ± 0.8 19 ± 0.8 24.5 ± 1 24.5 ± 1 28.5 ± 1 28.5 ± 1 31.5 ± 1.5 31.5 ± 1.5 39.5 ± 1.5 39.5 ± 1.5 18.5 ± 440 162 600 600 990 990 1350 1350 234 234 404 404 540 540 1750 677 1750 677 2620 1030 2620 1030 540 207 Page 18 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 3 1.5 1.6 0.7 1.1 4 4 8 8 12 12 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.4 1.4 16 3 1.5 1.6 0.7 2.3 16 3 1.5 1.6 0.7 2.3 24 3 1.5 1.6 0.7 2.7 2 2 2.5 2 0.7 1.1 4 2 2.5 2 0.7 1.1 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 0.8 14.5 ± 0.3 11.9 0.8 17 ± 0.8 0.3 13.6 17 ± 0.8 0.3 13.6 22.5 ± 1 0.3 17.8 22.5 ± 1 0.3 17.8 27 ± 1 0.3 22.9 27 ± 1 0.3 22.9 31.5 ± 0.4 36.2 1.5 31.5 ± 0.4 36.2 1.5 38.5 ± 0.4 40.7 1.5 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 540 207 1.5 1.5 1.8 1.8 1.9 1.9 0.8 18.5 ± 0.8 21 ± 1 21 ± 1 27 ± 1 27 ± 1 32 ± 1.5 32 ± 1.5 760 760 1270 1270 1750 1750 307 307 516 516 734 734 2.1 37 ± 1.5 2540 1032 2.1 37 ± 1.5 2540 1032 2.4 45 ± 2 3580 1417 1.4 8 2 2.5 2 0.7 1.1 14 ± 0.8 16.5 ± 0.8 22 ± 1 0.3 17.8 1.8 12 2 2.5 2 0.7 2.1 28 ± 1 0.3 22.9 1.9 16 24 2 2 2.5 2.5 2 2 0.9 0.9 2.3 2.7 33 ± 1.5 41 ± 2 0.4 0.4 31.7 40.7 2.1 2.4 27 ± 1 32.5 ± 1.5 39 ± 1.5 47.5 ± 2 4 3 2.5 2 0.7 1.1 0.3 15.3 1.6 23 ± 1 950 435 0.3 20.4 1.9 30 ± 1.5 1620 761 0.4 36.2 2.3 44.5 ± 2 3570 1473 8 3 2.5 2 0.7 1.1 16 3 2.5 2 0.9 2.6 18.5 ± 0.8 25 ± 1 38.5 ± 1.5 0.3 11.9 1.4 18 ± 0.8 530 217 0.3 13.6 1.5 20.5 ± 1 740 325 1230 551 1860 784 2600 3780 1054 1511 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Unshielded 16 and 24 pair 2,5 mm² Unshielded 16 triple 2,5 mm² 95 95 0,66 0,66 8,02 8,02 41,1 41,1 Ordering information New Part number Old Part number 20110651 20110652 20110653 20110654 20110655 20110656 20110657 20110658 20110659 20110660 893845 20109505 20118235 20110661 893867 20110662 20118161 20110663 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU(C) 2PAIR 0.75mm² S4/S8 BFOU(C) 2PAIR 0.75mm² S4/S8 BFOU(C) 4PAIR 0.75mm² S4/S8 BFOU(C) 4PAIR 0.75mm² S4/S8 BFOU(C) 8PAIR 0.75mm² S4/S8 BFOU(C) 8PAIR 0.75mm² S4/S8 BFOU(C) 12PAIR 0.75mm² S4/S8 BFOU(C) 12PAIR 0.75mm² S4/S8 BFOU(C) 16PAIR 0.75mm² S4/S8 BFOU(C) 16PAIR 0.75mm² S4/S8 BFOU(C) 19PAIR 0.75mm² S4/S8 BFOU(C) 24PAIR 0.75mm² S4/S8 BFOU(C) 24PAIR 0.75mm² S4/S8 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE Yes Yes Yes Yes Yes Yes Yes Yes Yes - 7021528938067 7021528938074 7021528938180 7021528938197 7021528938302 7021528938319 7021528938364 7021528938371 7021528938425 7021528938432 7021528938456 7021528938487 7021528938494 1043821 1043822 1043823 1043824 1043828 1043829 1043830 1043831 1043833 1043834 1043836 1043837 BFOU(C) 2TRIP 0.75mm² S4/S8 BFOU(C) 2TRIP 0.75mm² S4/S8 BFOU(C) 4TRIP 0.75mm² S4/S8 BFOU(C) 4TRIP 0.75mm² S4/S8 BFOU(C) 8TRIP 0.75mm² S4/S8 GREY BLUE GREY BLUE GREY - 7021528938661 7021528938678 7021528938784 7021528938791 7021528938906 1043921 1043922 1043924 1043925 1043928 Subject to change without prior notice Page 19 of 212 New Part Old Part number number 20113359 20110664 893897 20110665 893903 893908 EAN No. DNK EL No. BFOU(C) 8TRIP 0.75mm² S4/S8 BFOU(C) 12TRIP 0.75mm² S4/S8 BFOU(C) 12TRIP 0.75mm² S4/S8 BFOU(C) 16TRIP 0.75mm² S4/S8 BFOU(C) 16TRIP 0.75mm² S4/S8 BFOU(C) 24TRIP 0.75mm² S4/S8 BLUE GREY BLUE GREY BLUE GREY Yes - 7021528938913 7021528938968 7021528938975 7021528939026 7021528939033 7021528939088 1043929 1043930 1043931 1043933 1043934 1043936 20110666 20110667 20110668 20110669 20110670 20110671 20110672 20110673 20109506 20109507 20109508 20109509 BFOU(C) 2PAIR 1.5mm² S4/S8 BFOU(C) 2PAIR 1.5mm² S4/S8 BFOU(C) 4PAIR 1.5mm² S4/S8 BFOU(C) 4PAIR 1.5mm² S4/S8 BFOU(C) 8PAIR 1.5mm² S4/S8 BFOU(C) 8PAIR 1.5mm² S4/S8 BFOU(C) 12PAIR 1.5mm² S4/S8 BFOU(C) 12PAIR 1.5mm² S4/S8 BFOU(C) 16PAIR 1.5mm² S4/S8 BFOU(C) 16PAIR 1.5mm² S4/S8 BFOU(C) 24PAIR 1.5mm² S4/S8 BFOU(C) 24PAIR 1.5mm² S4/S8 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Yes Yes Yes Yes Yes Yes - 7021528940060 7021528940077 7021528940183 7021528940190 7021528940305 7021528940312 7021528940367 7021528940374 7021528940428 7021528940435 7021528940480 7021528940497 1043862 1043861 1043863 1043864 1043868 1043869 1043870 1043871 1043873 1043874 1043876 1043877 BFOU(C) 2TRIP 1.5mm² S4/S8 BFOU(C) 2TRIP 1.5mm² S4/S8 BFOU(C) 4TRIP 1.5mm² S4/S8 BFOU(C) 4TRIP 1.5mm² S4/S8 BFOU(C) 8TRIP 1.5mm² S4/S8 BFOU(C) 8TRIP 1.5mm² S4/S8 BFOU(C) 12TRIP 1.5mm² S4/S8 BFOU(C) 12TRIP 1.5mm² S4/S8 BFOU(C) 16TRIP 1.5mm² S4/S8 BFOU(C) 16TRIP 1.5mm² S4/S8 BFOU(C) 24TRIP 1.5mm² S4/S8 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY Yes Yes - 7021528940664 7021528940671 7021528940787 7021528940794 7021528940909 7021528940916 7021528940961 7021528940978 7021528941029 7021528941036 7021528941081 1043971 1043972 1043973 1043974 1043977 1043978 1043979 1043981 1043982 1043987 894248 BFOU(C) 2PAIR 2.5mm² S4/S8 BFOU(C) 4PAIR 2.5mm² S4/S8 BFOU(C) 8PAIR 2.5mm² S4/S8 BFOU(C) 8PAIR 2.5mm² S4/S8 BFOU(C) 12PAIR 2.5mm² S4/S8 BFOU(C) 16PAIR 2.5mm² S4/S8 BFOU(C) 24PAIR 2.5mm² S4/S8 GREY GREY GREY BLUE GREY GREY GREY - 7021528942064 7021528942187 7021528942309 7021528942316 7021528942361 7021528942422 7021528942484 - 894278 894290 894302 BFOU(C) 4TRIP 2.5mm² S4/S8 BFOU(C) 8TRIP 2.5mm² S4/S8 BFOU(C) 16TRIP 2.5mm² S4/S8 GREY GREY GREY - 7021528942781 7021528942903 7021528943023 - 20110775 894067 20110674 894079 20110675 894091 20109510 894097 20109511 894103 20110776 20110676 20110677 20110678 894231 20122326 20110777 Description Sheath Colour Stock item Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 20 of 212 Halogen-free, unarmoured mud resistant instrumentation cable RU(i) 150/250(300)V, S11 Flame retardant halogen-free instrumentation cable. Mud resistant RU(i) 150/250(300)V EPR/EVA NEK TS 606 CodeS11 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, IEC 60092-360 communication, Control and alarm systems in both IEC 60092-360 EX- (Zone 2) and safe areas. Meets the mud IEC 60332-1-2 resistant requirements in NEK TS 606:2009. IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Lay up / Shielding Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RU(i) 250V S11 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 21 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements Cross Copper content No of cores Conductor Insulation Thickness Outer Diameter outer Weight of Cable section core, Approx. in element Diameter, mm Thickness, mm Sheath, mm sheath, mm Approx. (Kg/Km) mm² (kg/km) 1 1 2 2 4 8 12 16 24 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1 1 1.1 1.1 1.2 1.3 1.4 1.5 1.7 6.5 ± 0.5 6.5 ± 0.5 10 ± 0.8 10 ± 0.8 11.5 ± 0.8 15.5 ± 0.8 18.5 ± 0.8 21 ± 1 25.5 ± 1 85 85 140 140 235 420 590 760 1120 17 17 34 34 67 133 199 265 397 1 2 4 8 12 16 24 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1 1.1 1.2 1.4 1.5 1.6 1.8 7 ± 0.5 11 ± 0.8 13 ± 0.8 18 ± 0.8 21 ± 1 23.5 ± 1 29 ± 1 95 175 290 540 770 990 1460 23 46 92 184 276 368 551 1 1 2 2 4 8 12 16 24 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1 1 1.2 1.2 1.3 1.5 1.6 1.7 2 8 ± 0.5 8 ± 0.5 12 ± 0.8 12 ± 0.8 14.5 ± 0.8 20 ± 1 23.5 ± 1 26.5 ± 1 32.5 ± 1.5 120 120 215 215 370 690 970 1260 1880 34 34 68 68 136 271 406 541 811 1 2 4 8 16 24 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1 1.3 1.3 1.6 1.9 2.2 8.5 ± 0.5 14 ± 0.8 16 ± 0.8 22.5 ± 1 30 ± 1.5 37 ± 1.5 140 285 470 900 1700 2520 48 96 192 383 765 1148 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² 110 110 0,67 0,67 26,3 26,3 12,7 12,7 Shielded pair 1,5 mm² Shielded triple 1,5 mm² 125 125 0,63 0,63 12,9 12,9 24,4 24,4 Shielded pair 2,5 mm² Shielded triple 2,5 mm² 145 145 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 20111817 20109512 895006 20112238 895018 895030 895036 895042 895048 Description RU(I) 250V 1PAIR 0.75mm² S11 RU(I) 250V 1PAIR 0.75mm² S11 RU(I) 250V 2PAIR 0.75mm² S11 RU(I) 250V 2PAIR 0.75mm² S11 RU(I) 250V 4PAIR 0.75mm² S11 RU(I) 250V 8PAIR 0.75mm² S11 RU(I) 250V 12PAIR 0.75mm² S11 RU(I) 250V 16PAIR 0.75mm² S11 RU(I) 250V 24PAIR 0.75mm² S11 Subject to change without prior notice Sheath Colour GREY BLUE GREY BLUE GREY GREY GREY GREY GREY Stock item - EAN No. DNK 7021528950007 7021528950014 7021528950069 7021528950076 7021528950182 7021528950304 7021528950366 7021528950427 7021528950489 Page 22 of 212 EL No. 1062100 1062101 1062106 1062107 1062118 1062130 1062136 1062142 1062148 New Part number Old Part number 20112177 Description Sheath Colour Stock item EAN No. DNK EL No. RU(I) 250V 1TRIP 0.75mm² S11 RU(I) 250V 2TRIP 0.75mm² S11 RU(I) 250V 4TRIP 0.75mm² S11 RU(I) 250V 8TRIP 0.75mm² S11 RU(I) 250V 12TRIP 0.75mm² S11 RU(I) 250V 16TRIP 0.75mm² S11 RU(I) 250V 24TRIP 0.75mm² S11 GREY GREY GREY GREY GREY GREY GREY - 7021528950601 7021528950663 7021528950786 7021528950908 7021528950960 7021528951028 7021528951080 1062160 1062166 1062178 1062190 1062194 1062196 1062198 895230 895236 895242 895248 RU(I) 250V 1PAIR 1.5mm² S11 RU(I) 250V 1PAIR 1.5mm² S11 RU(I) 250V 2PAIR 1.5mm² S11 RU(I) 250V 2PAIR 1.5mm² S11 RU(I) 250V 4PAIR 1.5mm² S11 RU(I) 250V 8PAIR 1.5mm² S11 RU(I) 250V 12PAIR 1.5mm² S11 RU(I) 250V 16PAIR 1.5mm² S11 RU(I) 250V 24PAIR 1.5mm² S11 GREY BLUE GREY BLUE GREY GREY GREY GREY GREY - 7021528952001 7021528952018 7021528952063 7021528952070 7021528952186 7021528952308 7021528952360 7021528952421 7021528952483 1062200 1062201 1062206 1062207 1062218 1062230 1062236 1062242 1062248 895260 895266 895278 895290 895302 895308 RU(I) 250V 1TRIP 1.5mm² S11 RU(I) 250V 2TRIP 1.5mm² S11 RU(I) 250V 4TRIP 1.5mm² S11 RU(I) 250V 8TRIP 1.5mm² S11 RU(I) 250V 16TRIP 1.5mm² S11 RU(I) 250V 24TRIP 1.5mm² S11 GREY GREY GREY GREY GREY GREY - 7021528952605 7021528952667 7021528952780 7021528952902 7021528953022 7021528953084 1062260 1062266 1062278 1062290 1062296 1062298 895066 895078 895090 895096 895102 895108 895200 895201 20110870 20110871 20110782 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 23 of 212 Halogen-free, unarmoured mud resistant instrumentation cable RU(c) 150/250(300)V, S12 Flame retardant halogen-free instrumentation cable. Mud resistant RU(c) 150/250(300)V EPR/EVA NEK TS 606 CodeS12 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, IEC 60092-360 communication, Control and alarm systems in both IEC 60092-360 EX- (Zone 2) and safe areas. Meets the mud IEC 60332-1-2 resistant requirements in NEK TS 606:2009. IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RU(c) 250V S12 2 pair 0,75 mm2 IEC 60092-376 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 24 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements Cross Copper content No of cores Conductor Insulation Thickness Outer Diameter outer Weight of Cable section core, Approx. in element Diameter, mm Thickness, mm Sheath, mm sheath, mm Approx. (Kg/Km) mm² (kg/km) 2 4 4 8 12 16 19 24 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.3 1.4 1.5 1.5 1.6 10 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 15.5 ± 0.8 18 ± 0.8 19.5 ± 0.8 20.5 ± 1 24 ± 1 135 195 195 380 510 640 730 910 30 55 55 106 158 209 247 311 2 4 4 8 16 24 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.2 1.2 1.4 1.6 1.8 11 ± 0.8 13 ± 0.8 13 ± 0.8 17.5 ± 0.8 22 ± 1 27 ± 1 170 265 265 490 870 1260 43 81 81 158 311 465 2 4 8 12 12 16 24 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.2 1.2 1.4 1.6 1.6 1.7 1.9 12 ± 0.8 14 ± 0.8 19.5 ± 0.8 22.5 ± 1 22.5 ± 1 24.5 ± 1 30 ± 1.5 210 320 610 850 850 1080 1550 62 118 229 340 340 452 674 2 4 8 12 16 24 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.2 1.3 1.5 1.7 1.8 2.1 13.5 ± 0.8 16 ± 0.8 21.5 ± 1 25.5 ± 1 27.5 ± 1 34 ± 1.5 265 430 820 1170 1500 2210 90 174 341 508 676 1011 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 895606 895618 895619 895630 895636 20132983 895645 20132984 895666 20110873 895679 895690 895702 Description Sheath Colour Stock item EAN No. DNK EL No. RU(C) 250V 2PAIR 0.75mm² S12 RU(C) 250V 4PAIR 0.75mm² S12 RU(C) 250V 4PAIR 0.75mm² S12 RU(C) 250V 8PAIR 0.75mm² S12 RU(C) 250V 12PAIR 0.75mm² S12 RU(C) 250V 16PAIR 0.75mm² S12 RU(C) 250V 19PAIR 0.75mm² S12 RU(C) 250V 24PAIR 0.75mm² S12 GREY GREY BLUE GREY GREY GREY GREY GREY - 7021528956061 7021528956184 7021528956191 7021528956306 7021528956368 7021528956429 7021528956450 7021528956481 1062506 1062518 1062530 1062536 1062542 1062545 1062548 RU(C) 250V 2TRIP 0.75mm² S12 RU(C) 250V 4TRIP 0.75mm² S12 RU(C) 250V 4TRIP 0.75mm² S12 RU(C) 250V 8TRIP 0.75mm² S12 RU(C) 250V 16TRIP 0.75mm² S12 GREY GREY BLUE GREY GREY - 7021528956665 7021528956788 7021528956795 7021528956900 7021528957020 1062566 1062578 1062590 1062603 Subject to change without prior notice Page 25 of 212 New Part number Old Part Description number 895708 RU(C) 250V 24TRIP 0.75mm² S12 20109513 Sheath Colour Stock item EAN No. DNK EL No. GREY - 7021528957082 1062608 895818 895830 895836 895837 895842 895848 RU(C) 250V 2PAIR 1.5mm² S12 RU(C) 250V 4PAIR 1.5mm² S12 RU(C) 250V 8PAIR 1.5mm² S12 RU(C) 250V 12PAIR 1.5mm² S12 RU(C) 250V 12PAIR 1.5mm² S12 RU(C) 250V 16PAIR 1.5mm² S12 RU(C) 250V 24PAIR 1.5mm² S12 GREY GREY GREY GREY BLUE GREY GREY - 7021528958065 7021528958188 7021528958300 7021528958362 7021528958379 7021528958423 7021528958485 1062706 1062718 1062730 1062736 1062737 1062742 1062748 895866 895878 895890 895896 895902 895908 RU(C) 250V 2TRIP 1.5mm² S12 RU(C) 250V 4TRIP 1.5mm² S12 RU(C) 250V 8TRIP 1.5mm² S12 RU(C) 250V 12TRIP 1.5mm² S12 RU(C) 250V 16TRIP 1.5mm² S12 RU(C) 250V 24TRIP 1.5mm² S12 GREY GREY GREY GREY GREY GREY - 7021528958669 7021528958782 7021528958904 7021528958966 7021528959024 7021528959086 1062766 1062778 1062790 1062794 1062796 1062798 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 26 of 212 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(i) 150/250(300)V, S13 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(i) 150/250(300)V MGT/EPR/EVA NEK TS 606 CodeS13 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, communication, control and alarm systems in both IEC 60092-360 IEC 60092-360 EX-(Zone 2) and safe areas, emergency and IEC 60332-1-2 critical systems where requirement for fire IEC 60332-3-22 resistance exists. Meets the mud resistant IEC 60331-1, -2, -21 requirements in NEK TS 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) "meter" "year" DRAKA 01 BU(i) 250V S13 8 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 27 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements Cross Copper content No of cores Conductor Insulation Thickness Outer Diameter outer Weight of Cable section core, Approx. in element Diameter, mm Thickness, mm Sheath, mm sheath, mm Approx. (Kg/Km) mm² (kg/km) 1 1 2 2 4 8 12 12 16 24 2 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1 1 1.2 1.2 1.2 1.4 1.6 1.6 1.7 1.9 7.5 ± 0.5 7.5 ± 0.5 11 ± 0.8 11 ± 0.8 13 ± 0.8 17.5 ± 0.8 21 ± 1 21 ± 1 23.5 ± 1 29 ± 1 95 95 165 165 260 490 700 700 900 1300 17 17 34 34 67 133 199 199 265 397 1 2 4 8 12 16 24 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1 1.2 1.3 1.5 1.7 1.8 2 7.5 ± 0.5 12 ± 0.8 14 ± 0.8 19.5 ± 0.8 23.5 ± 1 26 ± 1 32 ± 1.5 105 200 340 640 900 1170 1690 23 46 92 184 276 368 552 1 1 2 2 4 4 8 8 12 12 16 24 24 2 2 2 2 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1 1 1.3 1.3 1.4 1.4 1.6 1.6 1.7 1.7 1.9 2.2 2.2 8.5 ± 0.5 8.5 ± 0.5 13.5 ± 0.8 13.5 ± 0.8 16 ± 0.8 16 ± 0.8 22 ± 1 22 ± 1 26 ± 1 26 ± 1 29.5 ± 1 36.5 ± 1.5 36.5 ± 1.5 130 130 250 250 420 420 770 770 1100 1100 1440 2120 2120 34 34 68 68 136 136 271 271 406 406 541 812 812 1 1 2 4 8 12 16 24 3 3 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.3 1.4 1.7 1.9 2 2.4 9.5 ± 0.5 9.5 ± 0.5 14.5 ± 0.8 17.5 ± 0.8 23.5 ± 1 29 ± 1 32.5 ± 1.5 40.5 ± 2 165 165 310 530 1020 1470 1910 2860 48 48 96 192 384 575 767 1150 1 2 2.5 2 0.7 1.1 9.5 ± 0.5 170 55 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² 110 110 0,67 0,67 26,3 26,3 12,7 12,7 Shielded pair 1,5 mm² Shielded triple 1,5 mm² 125 125 0,63 0,63 12,9 12,9 24,4 24,4 Shielded pair 2,5 mm² Shielded triple 2,5 mm² 145 145 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 20109514 896201 Description BU(I) 250V 1PAIR 0.75mm² S13 BU(I) 250V 1PAIR 0.75mm² S13 Subject to change without prior notice Sheath Colour GREY BLUE Stock item - EAN No. DNK 7021528962000 7021528962017 EL No. 1063500 1063501 Page 28 of 212 896206 896207 896218 896230 896236 896237 896242 896248 BU(I) 250V 2PAIR 0.75mm² S13 BU(I) 250V 2PAIR 0.75mm² S13 BU(I) 250V 4PAIR 0.75mm² S13 BU(I) 250V 8PAIR 0.75mm² S13 BU(I) 250V 12PAIR 0.75mm² S13 BU(I) 250V 12PAIR 0.75mm² S13 BU(I) 250V 16PAIR 0.75mm² S13 BU(I) 250V 24PAIR 0.75mm² S13 GREY BLUE GREY GREY GREY BLUE GREY GREY - 7021528962062 7021528962079 7021528962185 7021528962307 7021528962369 7021528962376 7021528962420 7021528962482 1063506 1063507 1063518 1063530 1063536 1063542 1063548 896266 896278 896290 896296 896302 896308 BU(I) 250V 1TRIP 0.75mm² S13 BU(I) 250V 2TRIP 0.75mm² S13 BU(I) 250V 4TRIP 0.75mm² S13 BU(I) 250V 8TRIP 0.75mm² S13 BU(I) 250V 12TRIP 0.75mm² S13 BU(I) 250V 16TRIP 0.75mm² S13 BU(I) 250V 24TRIP 0.75mm² S13 GREY GREY GREY GREY GREY GREY GREY - 7021528962604 7021528962666 7021528962789 7021528962901 7021528962963 7021528963021 7021528963083 1063560 1063566 1063578 1063590 1063596 1063602 1063608 896419 896430 896431 896436 896437 896442 896448 896449 BU(I) 250V 1PAIR 1.5mm² S13 BU(I) 250V 1PAIR 1.5mm² S13 BU(I) 250V 2PAIR 1.5mm² S13 BU(I) 250V 2PAIR 1.5mm² S13 BU(I) 250V 4PAIR 1.5mm² S13 BU(I) 250V 4PAIR 1.5mm² S13 BU(I) 250V 8PAIR 1.5mm² S13 BU(I) 250V 8PAIR 1.5mm² S13 BU(I) 250V 12PAIR 1.5mm² S13 BU(I) 250V 12PAIR 1.5mm² S13 BU(I) 250V 16PAIR 1.5mm² S13 BU(I) 250V 24PAIR 1.5mm² S13 BU(I) 250V 24PAIR 1.5mm² S13 GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE - 7021528964004 7021528964011 7021528964066 7021528964073 7021528964189 7021528964196 7021528964301 7021528964318 7021528964363 7021528964370 7021528964424 7021528964486 7021528964493 1063700 1063701 1063706 1063707 1063718 1063730 1063736 1063737 1063742 1063748 - 896460 896461 896466 896478 896490 896496 896502 896508 BU(I) 250V 1TRIP 1.5mm² S13 BU(I) 250V 1TRIP 1.5mm² S13 BU(I) 250V 2TRIP 1.5mm² S13 BU(I) 250V 4TRIP 1.5mm² S13 BU(I) 250V 8TRIP 1.5mm² S13 BU(I) 250V 12TRIP 1.5mm² S13 BU(I) 250V 16TRIP 1.5mm² S13 BU(I) 250V 24TRIP 1.5mm² S13 GREY BLUE GREY GREY GREY GREY GREY GREY - 7021528964608 7021528964615 7021528964660 7021528964783 7021528964905 7021528964967 7021528965025 7021528965087 1063760 1063761 1063766 1063778 1063790 1063796 1063802 1063808 896600 BU(I) 250V 1PAIR 2.5mm² S13 GREY - 7021528966008 1063900 20119107 20109515 20109516 20109517 896407 20109518 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 29 of 212 Halogen-free, fire resistant, unarmoured, mud resistant instrumentation cable BU(c) 150/250(300)V, S14 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BU(c) 150/250(300)V MGT/EPR/EVA NEK TS 606 CodeS14 Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) IEC 60228 class 2 Fixed installation for instrumentation, communication, control and alarm systems in both IEC 60092-360 IEC 60092-360 EX-(Zone 2) and safe areas, emergency and IEC 60332-1-2 critical systems where requirement for fire IEC 60332-3-22 resistance exists. Meets the mud resistant IEC 60331-1, -2, 21 requirements in NEK TS 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour U Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) "meter" "year" DRAKA 01 BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 30 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number of elements Cross Copper content No of cores Conductor Insulation Thickness Outer Diameter outer Weight of Cable section core, Approx. in element Diameter, mm Thickness, mm Sheath, mm sheath, mm Approx. (Kg/Km) mm² (kg/km) 2 4 8 12 12 16 19 24 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.2 1.4 1.5 1.5 1.6 1.6 1.8 10.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 21.5 ± 1 22.5 ± 1 26.5 ± 1 150 230 420 570 570 720 820 1040 30 55 107 158 158 209 247 311 2 4 8 12 16 24 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 1.2 1.3 1.5 1.6 1.7 1.9 12 ± 0.8 14.5 ± 0.8 19.5 ± 0.8 22.5 ± 1 24.5 ± 1 30 ± 1.5 200 310 590 780 1000 1430 43 81 158 235 312 466 2 4 8 12 16 24 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.2 1.3 1.5 1.7 1.8 2.1 13 ± 0.8 15.5 ± 0.8 21 ± 1 24.5 ± 1 26.5 ± 1 33 ± 1.5 225 360 660 940 1200 1770 62 118 229 341 452 675 2 4 8 12 16 24 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 1.3 1.4 1.6 1.8 1.9 2.2 15 ± 0.8 17.5 ± 0.8 23.5 ± 1 28 ± 1 30.5 ± 1.5 37.5 ± 1.5 310 500 930 1300 1670 2470 90 174 342 509 677 1012 2 2 2.5 2.0 0.7 1.3 14.5 ± 0.8 295 96 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Ordering information New Part number Old Part number 20110778 20115554 20109519 20119162 896837 20119164 896845 20115190 20109520 20109521 20109522 896896 Description Sheath Colour Stock item EAN No. DNK EL No. BU(C) 250V 2PAIR 0.75mm² S14 BU(C) 250V 4PAIR 0.75mm² S14 BU(C) 250V 8PAIR 0.75mm² S14 BU(C) 250V 12PAIR 0.75mm² S14 BU(C) 250V 12PAIR 0.75mm² S14 BU(C) 250V 16PAIR 0.75mm² S14 BU(C) 250V 19PAIR 0.75mm² S14 BU(C) 250V 24PAIR 0.75mm² S14 GREY GREY GREY GREY BLUE GREY GREY GREY - 7021528968064 7021528968187 7021528968309 7021528968361 7021528968378 7021528968422 7021528968453 7021528968484 1064106 1064118 1064130 1064136 1064142 1064145 1064148 BU(C) 250V 2TRIP 0.75mm² S14 BU(C) 250V 4TRIP 0.75mm² S14 BU(C) 250V 8TRIP 0.75mm² S14 BU(C) 250V 12TRIP 0.75mm² S14 GREY GREY GREY GREY - 7021528968668 7021528968781 7021528968903 7021528968965 1064166 1064178 1064190 1064196 Subject to change without prior notice Page 31 of 212 New Part number 20119166 20109523 Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 896908 BU(C) 250V 16TRIP 0.75mm² S14 BU(C) 250V 24TRIP 0.75mm² S14 GREY GREY - 7021528969023 7021528969085 1064203 1064208 897006 897018 897030 897036 897042 897048 BU(C) 250V 2PAIR 1.5mm² S14 BU(C) 250V 4PAIR 1.5mm² S14 BU(C) 250V 8PAIR 1.5mm² S14 BU(C) 250V 12PAIR 1.5mm² S14 BU(C) 250V 16PAIR 1.5mm² S14 BU(C) 250V 24PAIR 1.5mm² S14 GREY GREY GREY GREY GREY GREY - 7021528970067 7021528970180 7021528970302 7021528970364 7021528970425 7021528970487 1064306 1064318 1064330 1064336 1064342 1064348 897066 897078 897090 897096 897102 897108 BU(C) 250V 2TRIP 1.5mm² S14 BU(C) 250V 4TRIP 1.5mm² S14 BU(C) 250V 8TRIP 1.5mm² S14 BU(C) 250V 12TRIP 1.5mm² S14 BU(C) 250V 16TRIP 1.5mm² S14 BU(C) 250V 24TRIP 1.5mm² S14 GREY GREY GREY GREY GREY GREY - 7021528970661 7021528970784 7021528970906 7021528970968 7021528971026 7021528971088 1064366 1064378 1064390 1064396 1064402 1064408 BU(C) 250V 2PAIR 2.5mm² S14 GREY - 7021528972061 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 32 of 212 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8 Flame retardant halogen-free power cable. Mud resistant RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Black Page 33 of 212 Core identification power cables Single core – Black Two cores - Blue – Brown Three cores - Brown - Black – Grey Four cores - Blue - Brown - Black – Grey Five cores - Blue - Brown - Black - Grey – Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue – Brown Three cores + earth (4G) - Yellow/green - Brown - Black – Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black – Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Diameter, mm Insulation Thickness, mm Thickness Inner covering, mm Diameter inner covering, mm Diameter Braid Wire, mm Mechanical cross-section of the braid, mm² Weight of Thickness Diameter Cable Outer outer Approx. Sheath, mm sheath, mm (Kg/Km) Copper content Approx. (kg/km) 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 2.5 4 6 6 10 10 10 10 10 16 16 5.15 6.45 7.65 9.0 10.85 12.60 14.20 15.90 17.70 20.15 22.60 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.2 9.5 ± 0.5 11.5 ± 0.8 12.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 20.5 ± 1 22.5 ± 1 24.5 ± 1 27.5 ± 1 30.5 ± 1.5 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 4.5 5.3 10.2 10.2 12.7 12.7 15.3 15.3 17.8 20.4 20.4 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 13 ± 0.8 14.5 ± 0.8 16 ± 0.8 18.5 ± 0.8 20.5 ± 1 23 ± 1 25 ± 1 27 ± 1 29.5 ± 1 32.5 ± 1.5 35.5 ± 1.5 360 490 650 840 1110 1400 1720 2060 2480 3130 3840 190 283 413 534 757 973 1231 1507 1838 2365 2959 2 3 4 5 7 12 19 27 37 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 4 4 6 6 6 10 10 10 16 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 9.5 ± 0.5 10 ± 0.8 11 ± 0.8 12 ± 0.8 12 ± 0.8 16 ± 0.8 19 ± 0.8 22.5 ± 1 25 ± 1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 5.3 5.3 8.5 10.2 10.2 13.6 15.3 17.8 20.4 1.2 1.2 1.3 1.3 1.3 1.5 1.6 1.8 1.9 12.5 ± 0.8 13.5 ± 0.8 14.5 ± 0.8 15.5 ± 0.8 16 ± 0.8 20 ± 1 23 ± 1 27 ± 1 30 ± 1.5 270 295 380 440 480 720 990 1310 1670 80 94 139 170 198 301 415 550 716 3G 4G 5G 7G 1.5 1.5 1.5 1.5 - 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 10 ± 0.8 11 ± 0.8 12 ± 0.8 12 ± 0.8 0.2 0.3 0.3 0.3 5.3 8.5 10.2 10.2 1.2 1.3 1.3 1.3 13.5 ± 0.8 14.5 ± 0.8 15.5 ± 0.8 16 ± 0.8 295 380 440 480 94 139 170 197 2 2.5 4 2.0 1.0 1.1 10.5 ± 0.8 0.2 5.3 1.2 13.5 ± 0.8 320 98 3 4 5 7 12 19 27 37 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 6 6 6 6 10 10 16 16 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.4 11 ± 0.8 12 ± 0.8 13 ± 0.8 13.5 ± 0.8 18 ± 0.8 21 ± 1 25 ± 1 28.5 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 8.5 10.2 10.2 11.9 15.3 17.8 20.4 22.9 1.3 1.3 1.4 1.4 1.6 1.7 1.9 2 14.5 ± 0.8 16 ± 0.8 17 ± 0.8 17.5 ± 0.8 22 ± 1 25.5 ± 1 30 ± 1.5 34 ± 1.5 390 460 530 610 930 1280 1720 2240 152 192 215 278 425 611 819 1074 3G 4G 5G 7G 2.5 2.5 2.5 2.5 - 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 11 ± 0.8 12 ± 0.8 13 ± 0.8 13.5 ± 0.8 0.3 0.3 0.3 0.3 8.5 10.2 10.2 11.9 1.3 1.3 1.4 1.4 14.5 ± 0.8 16 ± 0.8 17 ± 0.8 17.5 ± 0.8 390 460 530 610 152 192 215 277 2 3 4 5 4 4 4 4 6 6 6 6 2.55 2.55 2.55 2.55 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 11.5 ± 0.8 12 ± 0.8 13.5 ± 0.8 14.5 ± 0.8 0.3 0.3 0.3 0.3 8.5 10.2 10.2 11.9 1.3 1.3 1.4 1.4 15 ± 0.8 16 ± 0.8 17 ± 0.8 18.5 ± 0.8 410 480 560 660 157 210 247 300 3G 4G 5G 4 4 4 - 2.55 2.55 2.55 1.0 1.0 1.0 1.1 1.1 1.1 12 ± 0.8 13.5 ± 0.8 14.5 ± 0.8 0.3 0.3 0.3 10.2 10.2 11.9 1.3 1.4 1.4 16 ± 0.8 17 ± 0.8 18.5 ± 0.8 480 560 660 210 247 300 2 3 4 6 6 6 6 6 6 3.15 3.15 3.15 1.0 1.0 1.0 1.1 1.1 1.1 12.5 ± 0.8 13.5 ± 0.8 15 ± 0.8 0.3 0.3 0.3 10.2 10.2 11.9 1.3 1.4 1.4 16.5 ± 0.8 17.5 ± 0.8 18.5 ± 0.8 500 590 700 209 264 335 3G 4G 5G 6 6 6 - 3.15 3.15 3.15 1.0 1.0 1.0 1.1 1.1 1.1 13.5 ± 0.8 15 ± 0.8 16.5 ± 0.8 0.3 0.3 0.3 10.2 11.9 11.9 1.4 1.4 1.5 17.5 ± 0.8 18.5 ± 0.8 20.5 ± 1 590 700 820 264 335 390 Subject to change without prior notice Page 34 of 212 Electrical Cross section braid, mm² 10 10 10 Conductor Diameter, mm Insulation Thickness, mm 2 3 4 Cross section core, mm² 10 10 10 1.0 1.0 1.0 Thickness Inner covering, mm 1.1 1.1 1.1 Diameter inner covering, mm 14.5 ± 0.8 15.5 ± 0.8 17 ± 0.8 Diameter Braid Wire, mm 0.3 0.3 0.3 Mechanical cross-section of the braid, mm² 11.9 11.9 13.6 Weight of Thickness Diameter Cable Outer outer Approx. Sheath, mm sheath, mm (Kg/Km) 1.4 18.5 ± 0.8 670 1.4 19.5 ± 0.8 780 1.5 21 ± 1 950 Copper content Approx. (kg/km) 300 391 496 4.05 4.05 4.05 3G 4G 5G 10 10 10 - 4.05 4.05 4.05 1.0 1.0 1.0 1.1 1.1 1.2 15.5 ± 0.8 17 ± 0.8 19 ± 0.8 0.3 0.3 0.3 11.9 13.6 15.3 1.4 1.5 1.5 19.5 ± 0.8 21 ± 1 23 ± 1 780 950 1140 388 496 603 2 3 4 5 16 16 16 16 16 16 16 16 5.15 5.15 5.15 5.15 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 16.5 ± 0.8 17.5 ± 0.8 20 ± 1 22 ± 1 0.4 0.4 0.4 0.3 18.1 18.1 22.6 20.4 1.5 1.5 1.6 1.6 21 ± 1 22.5 ± 1 24.5 ± 1 26 ± 1 950 1120 1400 1590 481 626 806 930 3G 4G 5G 16 16 16 - 5.15 5.15 5.15 1.0 1.0 1.0 1.1 1.2 1.2 17.5 ± 0.8 20 ± 1 22 ± 1 0.3 0.3 0.3 13.6 15.3 15.3 1.5 1.6 1.6 22 ± 1 24 ± 1 26 ± 1 1060 1310 1540 571 734 881 2 3 4 25 25 25 16 16 16 6.45 6.45 6.45 1.2 1.2 1.2 1.2 1.2 1.2 20.5 ± 1 22 ± 1 24 ± 1 0.4 0.3 0.3 22.6 20.4 20.4 1.6 1.6 1.7 25.5 ± 1 26 ± 1 28.5 ± 1 1340 1560 1910 685 894 1125 3G 4G 5G 25 25 25 - 6.45 6.45 6.45 1.2 1.2 1.2 1.2 1.2 1.2 22 ± 1 24 ± 1 26.5 ± 1 0.3 0.3 0.3 15.3 17.8 20.4 1.6 1.7 1.8 26 ± 1 28.5 ± 1 31.5 ± 1.5 1510 1890 2260 844 1100 1356 2 3 4 35 35 35 16 16 16 7.65 7.65 7.65 1.2 1.2 1.2 1.2 1.2 1.2 23 ± 1 24.5 ± 1 27 ± 1 0.3 0.3 0.3 20.4 20.4 20.4 1.7 1.7 1.8 27.5 ± 1 29 ± 1 31.5 ± 1.5 1600 1930 2380 828 1142 1456 4G 5G 35 35 - 7.65 7.65 1.2 1.2 1.2 1.2 27 ± 1 30 ± 1.5 0.3 0.3 20.4 22.9 1.8 1.9 31.5 ± 1.5 35 ± 1.5 2380 2870 1456 1795 2 3 4 50 50 50 25 25 25 9.0 9.0 9.0 1.4 1.4 1.4 1.2 1.2 1.4 26.5 ± 1 28.5 ± 1 32 ± 1.5 0.4 0.4 0.4 31.7 31.7 31.7 1.8 1.9 2 31.5 ± 1.5 34 ± 1.5 37.5 ± 1.5 2190 2680 3320 1181 1617 2052 4G 5G 50 50 - 9.0 9.0 1.4 1.4 1.4 1.4 32 ± 1.5 35 ± 1.5 0.3 0.4 22.9 36.2 2 2.1 37 ± 1.5 41 ± 2 3230 4030 1966 2531 2 3 4 5 70 70 70 70 35 35 35 35 10.85 10.85 10.85 10.85 1.4 1.4 1.4 1.4 1.2 1.4 1.4 1.4 30.5 ± 1.5 33 ± 1.5 36.5 ± 1.5 40.5 ± 2 0.6 0.5 0.5 0.4 50.9 49.5 49.5 45.2 1.9 2 2.2 2.3 36.5 ± 1.5 39 ± 1.5 43 ± 2 46.5 ± 2 3040 3730 4600 5440 1782 2385 3018 3610 4G 5G 70 70 - 10.85 10.85 1.4 1.4 1.4 1.4 36.5 ± 1.5 40.5 ± 2 0.4 0.4 36.2 36.2 2.2 2.3 42.5 ± 2 46.5 ± 2 4470 5360 2888 3528 2 3 4 95 95 95 50 50 50 12.60 12.60 12.60 1.6 1.6 1.6 1.4 1.4 1.4 35 ± 1.5 37.5 ± 1.5 41.5 ± 2 0.6 0.5 0.5 61.1 56.5 63.6 2.1 2.2 2.4 41.5 ± 2 43.5 ± 2 48.5 ± 2 3960 4830 6020 2317 3126 4020 4G 95 - 12.60 1.6 1.4 41.5 ± 2 0.4 40.7 2.4 48 ± 2 5790 3796 2 3 4 120 120 120 60 60 60 14.20 14.20 14.20 1.6 1.6 1.6 1.4 1.4 1.6 38 ± 1.5 41 ± 2 46 ± 2 0.6 0.6 0.6 71.3 71.3 71.3 2.2 2.3 2.5 45 ± 2 48 ± 2 53.5 ± 2.5 4810 5950 7440 2891 3975 5100 4G 5G 120 120 - 14.20 14.20 1.6 1.6 1.6 1.6 46 ± 2 51 ± 2.5 0.4 0.5 45.2 49.5 2.5 2.7 52.5 ± 2.5 58.5 ± 2.5 7120 8610 4781 5909 4G 150 - 15.90 1.8 1.6 51 ± 2.5 0.5 49.5 2.7 58.5 ± 2.5 8790 5931 5G 150 - 15.90 1.8 1.8 57 ± 2.5 0.5 63.6 2.9 64.5 ± 3 10725 7445 4G 185 - 17.70 2.0 1.8 56.5 ± 2.5 0.5 56.5 2.9 64.5 ± 3 10700 7241 Number of elements Ordering information New Part number Old Part number 800000 800001 800002 800003 800004 800005 Description RFOU 0.6/1kV 1X 16/2.5 P1/P8 RFOU 0.6/1kV 1X 25/4mm² P1/P8 RFOU 0.6/1kV 1X 35/6mm² P1/P8 RFOU 0.6/1kV 1X 50/6mm² P1/P8 RFOU 0.6/1kV 1X 70/10mm² P1/P8 RFOU 0.6/1kV 1X 95/10mm² P1/P8 Subject to change without prior notice Sheath Colour BLACK BLACK BLACK BLACK BLACK BLACK Stock item - EAN No. DNK EL No. 7021528000009 7021528000016 7021528000023 7021528000030 7021528000047 7021528000054 1044206 1044207 1044208 1044210 Page 35 of 212 New Part number 20132989 20133004 Old Part number RFOU 0.6/1kV 1X 120/10 P1/P8 RFOU 0.6/1kV 1X 150/10 P1/P8 RFOU 0.6/1kV 1X 185/10 P1/P8 RFOU 0.6/1kV 1X 240/16 P1/P8 RFOU 0.6/1kV 1X 300/16 P1/P8 Sheath Colour BLACK BLACK BLACK BLACK BLACK EAN No. DNK EL No. Yes 7021528000061 7021528000078 7021528000085 7021528000092 7021528000108 1044211 1044213 1044214 1044215 800024 800025 RFOU 0.6/1kV 2X 1.5/4mm² P1/P8 RFOU 0.6/1kV 3X 1.5/4mm² P1/P8 RFOU 0.6/1kV 4X 1.5/6mm² P1/P8 RFOU 0.6/1kV 5X 1.5/6mm² P1/P8 RFOU 0.6/1kV 7X 1.5/6mm² P1/P8 RFOU 0.6/1kV 12X 1.5/10 P1/P8 RFOU 0.6/1kV 19X 1.5/10 P1/P8 RFOU 0.6/1kV 27X 1.5/10 P1/P8 RFOU 0.6/1kV 37X 1.5/16 P1/P8 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes Yes Yes Yes Yes - 7021528000153 7021528000184 7021528000191 7021528000207 7021528000214 7021528000221 7021528000238 7021528000245 7021528000252 1044220 1044240 1044260 1044305 1044307 1044312 1044319 1044327 1044337 800017 800026 800028 RFOU 0.6/1kV 3G 1.5mm² P1/P8 RFOU 0.6/1kV 4G 1.5mm² P1/P8 RFOU 0.6/1kV 5G 1.5mm² P1/P8 RFOU 0.6/1kV 7G 1.5mm² P1/P8 BLACK BLACK BLACK BLACK - 7021528000160 7021528000177 7021528000269 7021528000283 - RFOU 0.6/1kV 2X 2.5/4mm² P1/P8 RFOU 0.6/1kV 3X 2.5/6mm² P1/P8 RFOU 0.6/1kV 4X 2.5/6mm² P1/P8 RFOU 0.6/1kV 5X 2.5/6mm² P1/P8 RFOU 0.6/1kV 7X 2.5/6mm² P1/P8 RFOU 0.6/1kV 12X 2.5/10 P1/P8 RFOU 0.6/1kV 19X 2.5/10 P1/P8 RFOU 0.6/1kV 27X 2.5/16 P1/P8 RFOU 0.6/1kV 37X 2.5/16 P1/P8 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes Yes Yes - 7021528000290 7021528000320 7021528000351 7021528000368 7021528000375 7021528000382 7021528000399 7021528000405 7021528000412 1044221 1044241 1044261 1044355 1044357 1044362 1044369 1044377 1044387 800044 RFOU 0.6/1kV 3G 2.5mm² P1/P8 RFOU 0.6/1kV 4G 2.5mm² P1/P8 RFOU 0.6/1kV 5G 2.5mm² P1/P8 RFOU 0.6/1kV 7G 2.5mm² P1/P8 BLACK BLACK BLACK BLACK Yes - 7021528000306 7021528000337 7021528000344 7021528000443 - 800048 RFOU 0.6/1kV 2X 4/6mm² P1/P8 RFOU 0.6/1kV 3X 4/6mm² P1/P8 RFOU 0.6/1kV 4X 4/6mm² P1/P8 RFOU 0.6/1kV 5X 4/6mm² P1/P8 BLACK BLACK BLACK BLACK Yes Yes - 7021528000450 7021528000467 7021528000474 7021528000481 1044222 1044242 1044262 - 800043 800050 RFOU 0.6/1kV 3G 4mm² P1/P8 RFOU 0.6/1kV 4G 4mm² P1/P8 RFOU 0.6/1kV 5G 4mm² P1/P8 BLACK BLACK BLACK Yes - 7021528000498 7021528000436 7021528000504 - RFOU 0.6/1kV 2X 6/6mm² P1/P8 RFOU 0.6/1kV 3X 6/6mm² P1/P8 RFOU 0.6/1kV 4X 6/6mm² P1/P8 BLACK BLACK BLACK Yes Yes - 7021528000511 1044223 7021528000528 1044243 7021528000535 1044263 RFOU 0.6/1kV 3G 6mm² P1/P8 RFOU 0.6/1kV 4G 6mm² P1/P8 RFOU 0.6/1kV 5G 6mm² P1/P8 BLACK BLACK BLACK - 7021528000559 7021528000542 7021528000566 - RFOU 0.6/1kV 2X 10/10mm² P1/P8 RFOU 0.6/1kV 3X 10/10mm² P1/P8 RFOU 0.6/1kV 4X 10/10mm² P1/P8 BLACK BLACK BLACK Yes - 7021528000573 1044224 7021528000580 1044244 7021528000597 1044264 800060 800062 800061 RFOU 0.6/1kV 3G 10mm² P1/P8 RFOU 0.6/1kV 4G 10mm² P1/P8 RFOU 0.6/1kV 5G 10mm² P1/P8 BLACK BLACK BLACK - 7021528000603 7021528000627 7021528000610 - 800116 RFOU 0.6/1kV 2X 16/16mm² P1/P8 RFOU 0.6/1kV 3X 16/16mm² P1/P8 RFOU 0.6/1kV 4X 16/16mm² P1/P8 RFOU 0.6/1kV 5X 16/16mm² P1/P8 BLACK BLACK BLACK BLACK Yes Yes - 7021528000634 7021528000641 7021528000658 7021528001167 800068 800066 800067 RFOU 0.6/1kV 3G 16mm² P1/P8 RFOU 0.6/1kV 4G 16mm² P1/P8 RFOU 0.6/1kV 5G 16mm² P1/P8 BLACK BLACK BLACK - 7021528000689 7021528000665 7021528000672 - 800069 RFOU 0.6/1kV 2X 25/16mm² P1/P8 RFOU 0.6/1kV 3X 25/16mm² P1/P8 BLACK BLACK Yes 7021528000696 1044226 7021528000702 1044246 800008 20110465 20110466 20110467 20110469 20110470 20111209 20110471 20104950 20110472 20110468 20110473 20110475 20110476 800036 800037 20109423 20120716 800040 20114663 20110474 800033 20114348 20110477 20110478 20110479 20110480 20110481 20110482 20110483 800055 20117131 800056 20110484 20110485 20110486 20110487 20110488 20110489 20110490 Description Subject to change without prior notice Stock item 1044225 1044245 1044265 - Page 36 of 212 New Part number 20110491 Old Part number RFOU 0.6/1kV 4X 25/16mm² P1/P8 Sheath Colour BLACK Stock item Yes 7021528000719 1044266 800073 800072 800074 RFOU 0.6/1kV 3G 25mm² P1/P8 RFOU 0.6/1kV 4G 25mm² P1/P8 RFOU 0.6/1kV 5G 25mm² P1/P8 BLACK BLACK BLACK - 7021528000733 7021528000726 7021528000740 - 800075 RFOU 0.6/1kV 2X 35/16mm² P1/P8 RFOU 0.6/1kV 3X 35/16mm² P1/P8 RFOU 0.6/1kV 4X 35/16mm² P1/P8 BLACK BLACK BLACK Yes - 7021528000757 7021528000764 1044247 7021528000771 1044267 800078 800079 RFOU 0.6/1kV 4G 35mm² P1/P8 RFOU 0.6/1kV 5G 35mm² P1/P8 BLACK BLACK - 7021528000788 7021528000795 - 800081 RFOU 0.6/1kV 2X 50/25mm² P1/P8 RFOU 0.6/1kV 3X 50/25mm² P1/P8 RFOU 0.6/1kV 4X 50/25mm² P1/P8 BLACK BLACK BLACK Yes - 7021528000818 7021528000825 1044248 7021528000832 1044268 800084 800085 RFOU 0.6/1kV 4G 50mm² P1/P8 RFOU 0.6/1kV 5G 50mm² P1/P8 BLACK BLACK - 7021528000849 7021528000856 - 800087 800089 800092 RFOU 0.6/1kV 2X 70/35mm² P1/P8 RFOU 0.6/1kV 3X 70/35mm² P1/P8 RFOU 0.6/1kV 4X 70/35mm² P1/P8 RFOU 0.6/1kV 5X 70/35mm² P1/P8 BLACK BLACK BLACK BLACK Yes - 7021528000870 7021528000887 7021528000894 7021528000924 800090 800091 RFOU 0.6/1kV 4G 70mm² P1/P8 RFOU 0.6/1kV 5G 70mm² P1/P8 BLACK BLACK - 7021528000900 7021528000917 - 800094 RFOU 0.6/1kV 2X 95/50mm² P1/P8 RFOU 0.6/1kV 3X 95/50mm² P1/P8 RFOU 0.6/1kV 4X 95/50mm² P1/P8 BLACK BLACK BLACK Yes Yes 7021528000948 7021528000955 1044250 7021528000962 1044270 800097 RFOU 0.6/1kV 4G 95mm² P1/P8 BLACK - 7021528000979 - 800105 RFOU 0.6/1kV 2X 120/60 P1/P8 RFOU 0.6/1kV 3X 120/60 P1/P8 RFOU 0.6/1kV 4X 120/60 P1/P8 BLACK BLACK BLACK Yes - 7021528001006 7021528001013 1044251 7021528001051 - 800106 800099 RFOU 0.6/1kV 4G 120mm² P1/P8 RFOU 0.6/1kV 5G 120mm² P1/P8 BLACK BLACK - 7021528001068 7021528000993 - RFOU 0.6/1kV 4G 150mm² P1/P8 RFOU 0.6/1kV 5G 150mm² P1/P8 BLACK BLACK - 7021528001082 7021528001150 - RFOU 0.6/1kV 4G 185mm² P1/P8 BLACK - 7021528001105 - 20110492 20110493 20110494 20110495 20109424 20109426 20109427 20109428 20109429 20114321 20132887 800110 Description EAN No. DNK EL No. 1044249 1044269 - Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 2.5 4 6 6 10 10 10 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.116 0.110 0.106 0.104 0.099 0.097 0.094 0.092 0.091 0.089 0.087 0.140 0.132 0.128 0.125 0.119 0.116 0.113 0.111 0.109 0.107 0.105 96 127 157 196 242 293 339 389 444 522 601 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 2 3 4 5 1.5 1.5 1.5 1.5 4 4 6 6 STCC STCC STCC STCC 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 0.110 0.110 0.110 0.110 0.132 0.132 0.132 0.132 20 16 16 13.5 210 210 210 210 Subject to change without prior notice Page 37 of 212 Number of elements 7 12 19 27 37 Cross section core, mm² 1.5 1.5 1.5 1.5 1.5 3G 4G 5G 7G Electrical Cross section braid, mm² 6 10 10 10 16 Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating type 2 resistance at resistance at 50Hz, 60Hz, IEC 6009220°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, Ampere STCC 12.2 15.6 0.110 0.132 12 STCC 12.2 15.6 0.110 0.132 10 STCC 12.2 15.6 0.110 0.132 8.5 STCC 12.2 15.6 0.110 0.132 7.5 STCC 12.2 15.6 0.110 0.132 7 Short circuit rating 1 second, Ampere 210 210 210 210 210 1.5 1.5 1.5 1.5 - STCC STCC STCC STCC 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 0.110 0.110 0.110 0.110 0.132 0.132 0.132 0.132 20 16 16 12.5 210 210 210 210 2 3 4 5 7 12 19 27 37 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 6 6 6 6 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.123 26 21 21 17.5 15.5 13 11 10 9 350 350 350 350 350 350 350 350 350 3G 4G 5G 7G 2.5 2.5 2.5 2.5 - STCC STCC STCC STCC 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 0.103 0.103 0.103 0.103 0.123 0.123 0.123 0.123 26 21 21 16.5 350 350 350 350 2 3 4 5 4 4 4 4 6 6 6 6 STCC STCC STCC STCC 4.7 4.7 4.7 4.7 5.99 5.99 5.99 5.99 0.096 0.096 0.096 0.096 0.115 0.115 0.115 0.115 34 28 28 23.5 560 560 560 560 3G 4G 5G 4 4 4 - STCC STCC STCC 4.7 4.7 4.7 5.99 5.99 5.99 0.096 0.096 0.096 0.115 0.115 0.115 34 28 28 560 560 560 2 3 4 6 6 6 6 6 6 STCC STCC STCC 3.11 3.11 3.11 3.97 3.97 3.97 0.090 0.090 0.090 0.108 0.108 0.108 44 36 36 840 840 840 3G 4G 5G 6 6 6 - STCC STCC STCC 3.11 3.11 3.11 3.97 3.97 3.97 0.090 0.090 0.090 0.108 0.108 0.108 44 36 36 840 840 840 2 3 4 10 10 10 10 10 10 STCC STCC STCC 1.84 1.84 1.84 2.35 2.35 2.35 0.084 0.084 0.084 0.101 0.101 0.101 61 50 50 1400 1400 1400 3G 4G 5G 10 10 10 - STCC STCC STCC 1.84 1.84 1.84 2.35 2.35 2.35 0.084 0.084 0.084 0.101 0.101 0.101 61 50 50 1400 1400 1400 2 3 4 5 16 16 16 16 16 16 16 16 STCC STCC STCC STCC 1.16 1.16 1.16 1.16 1.48 1.48 1.48 1.48 0.080 0.080 0.080 0.080 0.096 0.096 0.096 0.096 80 67 67 56 2240 2240 2240 2240 3G 4G 5G 16 16 16 - STCC STCC STCC 1.16 1.16 1.16 1.48 1.48 1.48 0.080 0.080 0.080 0.096 0.096 0.096 80 67 67 2240 2240 2240 2 3 4 25 25 25 16 16 16 STCC STCC STCC 0.734 0.734 0.734 0.936 0.936 0.936 0.079 0.079 0.079 0.095 0.095 0.095 108 89 89 3500 3500 3500 3G 4G 5G 25 25 25 - STCC STCC STCC 0.734 0.734 0.734 0.936 0.936 0.936 0.079 0.079 0.079 0.095 0.095 0.095 108 89 89 3500 3500 3500 2 35 16 STCC 0.529 0.675 0.076 0.092 133 4900 Subject to change without prior notice Page 38 of 212 Number of elements 3 4 Cross section core, mm² 35 35 Electrical Conductor Cross type 2 section braid, mm² 16 STCC 16 STCC Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 0.529 0.675 0.076 0.092 110 4900 0.529 0.675 0.076 0.092 110 4900 4G 5G 35 35 - STCC STCC 0.529 0.529 0.675 0.675 0.076 0.076 0.092 0.092 110 110 4900 4900 2 3 4 50 50 50 25 25 25 STCC STCC STCC 0.391 0.391 0.391 0.499 0.499 0.499 0.076 0.076 0.076 0.092 0.092 0.092 167 137 137 7000 7000 7000 4G 5G 50 50 - STCC STCC 0.391 0.391 0.499 0.499 0.076 0.076 0.092 0.092 137 137 7000 7000 2 3 4 5 70 70 70 70 35 35 35 35 STCC STCC STCC STCC 0.27 0.27 0.27 0.27 0.344 0.344 0.344 0.344 0.074 0.074 0.074 0.074 0.088 0.088 0.088 0.088 206 169 169 141.5 9800 9800 9800 9800 4G 5G 70 70 - STCC STCC 0.27 0.27 0.344 0.344 0.074 0.074 0.088 0.088 169 169 9800 9800 2 3 4 95 95 95 50 50 50 STCC STCC STCC 0.195 0.195 0.195 0.249 0.249 0.249 0.073 0.073 0.073 0.088 0.088 0.088 249 205 205 13300 13300 13300 4G 95 - STCC 0.195 0.249 0.073 0.088 205 13300 2 3 4 120 120 120 60 60 60 STCC STCC STCC 0.154 0.154 0.154 0.196 0.196 0.196 0.072 0.072 0.072 0.086 0.086 0.086 288 237 237 16800 16800 16800 4G 5G 120 120 - STCC STCC 0.154 0.154 0.196 0.196 0.072 0.072 0.086 0.086 237 237 16800 16800 4G 5G 150 150 - STCC STCC 0.126 0.126 0.161 0.161 0.072 0.072 0.087 0.087 272 272 21000 21000 4G 185 - STCC 0.1 0.128 0.072 0.086 311 25900 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 39 of 212 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables Flame retardant halogen-free power cable. Mud resistant. Single core cable. RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 mm2 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Black Page 40 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 ED 5.0 2010-08 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² 1 400 25 26.00 2.6 1.4 1 1 500 630 25 25 29.0 32.80 2.8 2.8 1.4 1.4 Diameter inner covering, mm 34.5 ± 1.5 38 ± 1.5 41.5 ± 2 Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 0.4 31.7 2.1 40.5 ± 2 5070 3970 0.4 0.4 36.2 40.7 2.2 2.3 44 ± 2 48 ± 2 6220 7650 4923 6195 Ordering information New Part number Old Part number 20110761 800012 800013 Description Sheath Colour Stock item RFOU 0.6/1kV 1X 400/25 P1/P8 RFOU 0.6/1kV 1X 500/25 P1/P8 RFOU 0.6/1kV 1X 630/25 P1/P8 BLACK BLACK BLACK - EAN No. DNK EL No. 7021528000115 7021528000122 7021528000139 - Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 1 400 25 STCC 0.0475 0.0606 0.087 0.104 1 500 25 STCC 0.0369 0.0471 0.085 0.103 1 630 25 STCC 0.0286 0.0365 0.083 0.100 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac 56000 70000 88200 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 41 of 212 Halogen-free, mud resistant power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided Flame retardant halogen-free power cable. Mud resistant. Double braided. RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application IEC 60092-353 Fixed installation for power,control and lighting in both EX IEC 60228 class 2 IEC 60092-360 (Zone 0, 1 & 2)- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning IEC 60092-360 fluids. Meets the MUD resistance requirement in NEK TS IEC 60332-1-2 IEC 60332-3-22 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape + rubberized Polyamide tape O Two layers of tinned copper wire braid (double braid) PET tape + rubberized Polyamide tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Black Page 42 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 ED 5.0 2010-08 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 3 4 150 150 75 75 15.9 15.9 1.8 1.8 1.6 2 46 ± 2 0.4 51.5 ± 2.5 0.5 90.5 99 2.6 2.8 54 ± 2.5 61 ± 3 7470 9480 4981 6444 3 4 185 185 95 95 17.70 17.7 2.0 2.0 1.6 2 50.5 ± 2.5 0.5 57 ± 2.5 0.5 127.2 113.1 2.7 3 59.5 ± 2.5 9230 67 ± 3 11430 6283 7837 3 240 120 20.15 2.2 1.8 57.5 ± 2.5 0.6 142.5 3 68 ± 3 8046 EAN No. DNK EL No. 11800 Ordering information New Part number Old Part number Description 20109430 Sheath Colour Stock item 800109 RFOU 0.6/1kV 3X 150/75 P1/P8 RFOU 0.6/1kV 4X 150/75 P1/P8 BLACK BLACK - 7021528001020 1044252 7021528001099 - 800111 RFOU 0.6/1kV 3X 185/95 P1/P8 RFOU 0.6/1kV 4X 185/95 P1/P8 BLACK BLACK - 7021528000931 7021528001112 - RFOU 0.6/1kV 3X 240/120 P1/P8 BLACK - 7021528001129 - 20109425 20109431 Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 3 4 150 150 75 75 STCC STCC 0.126 0.126 0.161 0.161 0.072 0.072 0.087 0.087 272 272 21000 21000 3 4 185 185 95 95 STCC STCC 0.1 0.1 0.128 0.128 0.072 0.072 0.086 0.086 311 311 25900 25900 3 240 120 STCC 0.0762 0.0972 0.072 0.086 365 33600 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 43 of 212 Halogen-free, mud resistant MV power cable, RFOU 3,6/6(7,2)kV, P2/P9 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 3,6/6(7,2) kV EPR/EPR/TCWB/EVA NEK 606 CodeP2/P9 Operating temperature Operating Voltage : 90°C : 3,6/6(7,2) kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC 60092-354 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 04 RFOU 3,6/6(7,2)KV P2/P9 3 x 120/60 mm2 IEC 60332-3-22 DRAKA 04 = Draka Industrial Cable, Germany Red Page 44 of 212 Range and dimensions Cross Number section of core, elements mm² 1 16 1 25 1 35 1 50 1 70 1 95 1 120 1 150 1 185 1 240 1 300 Cross section screen, mm² 11 11 13 13 16 16 20 22 25 25 30 Conductor Diameter, mm Insulation Thickness, mm 5,2 6,5 7,4 8,8 10,3 12,1 13,6 15,1 16,8 19,1 21,5 3 3 3 3 3 3 3 3 3 3 3 35 35 35 35 45 50 60 75 95 95 95 5,2 6,5 7,4 8,8 10,3 12,1 13,6 15,1 16,8 19,1 21,5 16 25 35 50 70 95 120 150 185 240 300 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,6 2,8 Thickness Inner covering, mm 1,0 1,0 1,0 1,0 1,0 1,0 1,0 1,2 1,2 1,2 1,2 Diameter inner covering, mm 16,5±1,0 18,0±1,0 19,0±1,0 20,5±1,0 22,0±1,0 24,0±1,5 25,0±1,5 27,0±1,5 28,5±1,5 31,5±1,5 34,0±1,5 Thickness Diameter Outer Braid Sheath, Wire, mm mm 0,3 1,6 0,3 1,6 0,3 1,6 0,3 1,7 0,3 1,8 0,3 1,9 0,4 1,9 0,4 2,0 0,4 2,0 0,4 2,1 0,4 2,2 Diameter outer sheath, mm 22,0±1,5 23,0±1,5 24,0±1,5 25,5±1,5 27,5±1,5 29,5±1,5 31,5±2,0 33,5±2,0 35,0±2,0 37,5±2,0 41,0±2,5 Weight of Cable Approx. (Kg/Km) 850 970 1150 1300 1600 2000 2300 2710 3230 3930 4700 Copper content Approx. (kg/km) 452 554 675 830 1060 1323 1677 2041 2433 2993 3626 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,5 2,6 2,8 1,2 1,2 1,2 1,4 1,4 1,4 1,6 1,6 1,6 1,8 1,8 34,5±1,5 37,5±1,5 39,5±1,5 43,0±2,0 46,0±2,0 50,0±2,0 53.5±2.0 56,5±2,0 60,5±2,5 66,5±2,5 70,0±3,0 0,4 0,4 0,4 0,4 0,5 0,5 0.5 0,5 0,6 0,6 0,6 42,0±2,5 45,0±2,5 47,0±2,5 50,5±3,0 54,5±3,0 58,5±3,0 62.5±3.5 66,5±3,5 70,0±3,5 77,0±4,0 80,5±4,5 3100 3570 4020 4700 5900 7200 8200 9600 11250 14000 16500 1419 1706 1972 2462 3047 4108 4988 6173 7364 9033 10794 2,3 2,4 2,5 2,6 2,7 2,8 3,0 3,1 3,2 3,5 3,6 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 804200 804201 804202 804203 804204 804205 804206 804207 804208 804209 804210 RFOU 3.6/6KV 1X 16/11mm² P2/P9 RFOU 3.6/6KV 1X 25/11mm² P2/P9 RFOU 3.6/6KV 1X 35/13mm² P2/P9 RFOU 3.6/6KV 1X 50/13mm² P2/P9 RFOU 3.6/6KV 1X 70/16mm² P2/P9 RFOU 3.6/6KV 1X 95/16mm² P2/P9 RFOU 3.6/6KV 1X 120/20mm² P2/P9 RFOU 3.6/6KV 1X 150/22mm² P2/P9 RFOU 3.6/6KV 1X 185/25mm² P2/P9 RFOU 3.6/6KV 1X 240/25mm² P2/P9 RFOU 3.6/6KV 1X 300/30mm² P2/P9 RED RED RED RED RED RED RED RED RED RED RED - 7021528042009 7021528042016 7021528042023 7021528042030 7021528042047 7021528042054 7021528042061 7021528042078 7021528042085 7021528042092 7021528042108 - 804220 804221 804222 804223 804224 804225 804226 804227 804228 804229 804230 RFOU 3.6/6KV 3X 16/35mm² P2/P9 RFOU 3.6/6KV 3X 25/35mm² P2/P9 RFOU 3.6/6KV 3X 35/35mm² P2/P9 RFOU 3.6/6KV 3X 50/35mm² P2/P9 RFOU 3.6/6KV 3X 70/45mm² P2/P9 RFOU 3.6/6KV 3X 95/50mm² P2/P9 RFOU 3.6/6KV 3X 120/60mm² P2/P9 RFOU 3.6/6KV 3X 150/75mm² P2/P9 RFOU 3.6/6KV 3X 185/95mm² P2/P9 RFOU 3.6/6KV 3X 240/95mm² P2/P9 RFOU 3.6/6KV 3X 300/95mm² P2/P9 RED RED RED RED RED RED RED RED RED RED RED - 7021528042207 7021528042214 7021528042221 7021528042238 7021528042245 7021528042252 7021528042269 7021528042276 7021528042283 7021528042290 7021528042306 - Subject to change without prior notice Page 45 of 212 Electrical values power cables Number of elements Cross section core, mm² Cross section screen, mm² Conductor type 2 Max. Max. conductor conductor resistance at resistance at 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nF/km Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 11 11 13 13 16 16 20 22 25 25 30 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1,16 0,734 0,529 0,391 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 0,149 0,139 0,133 0,126 0,121 0,115 0,119 0,109 0,105 0,102 0,099 0,179 0,167 0,160 0,152 0,145 0,138 0,143 0,131 0,127 0,122 0,119 310 360 390 440 490 560 610 660 730 780 810 96 127 157 196 242 293 339 389 444 522 601 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 3 3 3 3 3 3 3 3 3 3 3 16 25 35 50 70 95 120 150 185 240 300 35 35 35 35 45 50 60 75 95 95 95 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1,16 0,734 0,529 0,391 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 0,121 0,112 0,108 0,102 0,097 0,093 0.090 0,088 0,085 0,083 0,082 0,145 0,135 0,129 0,123 0,117 0,112 0,108 0,105 0,102 0,100 0,098 310 360 390 440 490 560 610 660 730 780 810 67 89 110 137 169 205 237 272 311 365 421 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 Installation recommendations Minimum Bending Radius during Installation 15 x D Minimum Bending Radius Fixed Installed 9xD Subject to change without prior notice Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 46 of 212 80 0.47 Halogen-free, mud resistant MV power cable, RFOU 6/10(12)kV, P3/P10 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 6/10(12) kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP3/P10 Operating temperature Operating Voltage : 90°C : 6/10(12) kV Standards applied Application IEC 60092-354 IEC 60228 class 2 Fixed installation for medium voltage (MV) power in both EX- IEC 60092-360 and safe areas, general purposes. For installation in areas IEC 60092-360 exposed to MUD and drilling/cleaning fluids. Meets the MUD IEC 60332-1-2 resistance requirement in NEK TS 606:2009 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 04 RFOU 6/10(12)KV P3/P10 3 x 95/50 mm2 IEC 60332-3-22 DRAKA 04 = Draka Industrial Cable, Germany Red Page 47 of 212 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm 1 16 11 5.2 3.4 1.0 18.5 ±1.0 0.3 12.7 1.6 1 25 11 6.5 3.4 1.0 20,0 ±1.0 0.3 12.7 1.7 1 35 11 7.4 3.4 1.0 0.3 12.7 1.7 1 50 11 8.8 3.4 1.0 0.3 12.7 1.9 1 70 16 10.3 3.4 1.0 23.5 ±1.5 0.3 17.8 1.9 1 95 16 12.1 3.4 1.2 25.5 ±1.5 0.3 20.4 2.0 1 120 20 13.6 3.4 1.2 27.5 ± 1.5 0.3 22.9 2.0 1 150 19 15.1 3.4 1.2 28.5 ±1.5 0.3 20.4 2.0 1 185 18 16.8 3.4 1.2 30.5 ±1.5 0.3 20.4 2.1 1 240 21 19.1 3.4 1.2 33.0 ± 1.5 0.3 22.9 2.1 1 300 29 21.5 3.4 1.2 35 ±1.5 0.3 30.5 2.2 1 400 35 24.5 3.4 1.2 36 ±1.5 0.4 40.7 2.3 1 500 40 27.5 3.4 1.4 0.4 49.8 2.5 1 630 40 32.3 3.4 1.4 0.4 49.8 2.7 3 16 32 5.2 3.4 1.4 0.4 36.2 2.4 3 25 31 6.5 3.4 1.4 0.4 31 2.4 3 35 35 7.4 3.4 1.4 0.4 35 3 50 31 8.8 3.4 1.6 0.4 3 70 35 10.3 3.4 1.6 3 95 50 12.1 3.4 1.6 3 120 60 13.6 3.4 1.6 3 150 75 15.1 3.4 1.6 3 185 45 16.8 3.4 1.6 3 240 53 19.1 3.4 1.6 3 300 55 21.5 3.4 1.6 21.0 ± 1.5 22.0 ± 1.0 41.5 ± 2.0 46.5 ± 2.0 39.0 ± 1.5 42.0 ± 1.5 43.5 ± 2.0 47.0 ± 2.0 50.0 ± 2.0 54.0 ± 2.0 57.5 ± 2.0 60 ± 2 64.5 ± 2.5 69.5 ± 2.5 74.5 ± 3.0 Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 900 420 1100 516 26.0± 1.5 1200 611 24.0 ± 1,5 25.0 ± 1,5 28.0 ± 1.5 30.0 ± 2.0 32.0 ± 2.0 34.0 ± 2.0 35.0 ± 2.0 36.5 ± 2.0 1450 780 1700 971 2100 1251 2350 1506 2600 1793 3100 2138 39.0± 2.0 3800 2702 41.5 ± 2.5 45.5 ± 2.5 49.5 ± 2.5 54.5 ± 3.0 4600 3395 5900 4536 7350 5782 8750 7016 3300 1145 3800 1465 2.5 51.5± 3.0 4300 1573 31 2.8 55 ± 3 5000 2124 0.4 40.7 2.8 58.5 ± 3 6000 2880 0.4 54.3 2.8 62.5± 3.0 7500 3975 0.5 70.7 3 0.6 86.5 3.2 0.5 56.5 3.3 0.5 63.6 0.5 70.7 46.0 ± 2.5 49.5 ± 2.5 66.5 ± 3.0 70.5 ± 3 74.0 ± 3.5 8350 4650 9800 5634 11300 6511 3.5 79.5± 3.5 13300 8609 3.7 85.0± 4.0 16300 10725 Ordering information New Part number Old Part number 804000 804001 804002 20080191 20113313 804005 20076157 804007 20098204 20077819 20076156 804011 804012 Description RFOU 6/10KV 1X 16/11mm² P3/P10 RFOU 6/10KV 1X 25/11mm² P3/P10 RFOU 6/10KV 1X 35/11mm² P3/P10 RFOU 6/10KV 1X 50/11mm² P3/P10 RFOU 6/10KV 1X 70/16mm² P3/P10 RFOU 6/10KV 1X 95/16mm² P3/P10 RFOU 6/10KV 1X 120/20mm² P3/P10 RFOU 6/10KV 1X 150/19mm² P3/P10 RFOU 6/10KV 1X185/18mm² P3/P10 RFOU 6/10KV 1X 240/21mm² P3/P10 RFOU 6/10KV 1X 300/29mm² P3/P10 RFOU 6/10KV 1X 400/35mm² P3/P10 RFOU 6/10KV 1X 500/40mm² P3/P10 Subject to change without prior notice Sheath Colour RED RED RED RED RED RED RED RED RED RED RED RED RED Stock item Yes Yes Yes - EAN No. DNK 7021528040005 7021528040012 7021528040029 7021528040036 7021528040043 7021528040050 7021528040067 7021528040074 7021528040081 7021528040098 7021528040104 7021528040111 7021528040128 Page 48 of 212 EL No. 1061020 1061021 1061000 1061001 1061002 1061003 1061004 1061005 1061006 1061007 1061008 1061022 1061023 New Part number Old Part Description number 804013 RFOU 6/10KV 1X 630/40mm² P3/P10 804020 804021 804022 804023 20076430 20076152 20086406 20076162 20077823 804029 804030 RFOU 6/10KV 3X 16/32mm² P3/P10 RFOU 6/10KV 3X 25/31mm² P3/P10 RFOU 6/10KV 3X 35/35mm² P3/P10 RFOU 6/10KV 3X 50/31mm² P3/P10 RFOU 6/10KV 3X 70/35mm² P3/P10 RFOU 6/10KV 3X 95/50mm² P3/P10 RFOU 6/10KV 3X 120/60mm² P3/P10 RFOU 6/10KV 3X 150/75mm² P3/P10 RFOU 6/10KV 3X 185/45mm² P3/P10 RFOU 6/10KV 3X 240/53mm² P3/P10 RFOU 6/10KV 3X 300/55mm² P3/P10 Sheath Colour Stock item EAN No. DNK EL No. RED - 7021528040135 1061024 RED RED RED RED RED RED RED RED RED RED RED - 7021528040203 7021528040210 7021528040227 7021528040234 7021528040241 7021528040258 7021528040265 7021528040272 7021528040289 7021528040296 7021528040302 1061009 1061010 1061011 1061012 1061013 1061014 1061015 1061016 1061017 1061018 1061019 Electrical values power cables Number of elements Cross section core, mm² Electrical Conductor Max. Max. Cross type 2 conductor conductor section resistance at resistance at braid, mm² 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nF/km 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 11 11 11 11 16 16 20 19 18 21 29 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.154 0.144 0.138 0.132 0.125 0.119 0.116 0.111 0.108 0.104 0.104 0.185 0.173 0.166 0.158 0.150 0.142 0.139 0.133 0.130 0.125 0.124 220 250 270 300 340 380 410 450 480 540 590 1 400 35 STCC 0.0475 0.0606 0.090 0.118 660 1 500 40 STCC 0.0369 0.0471 0.097 0.117 720 1 630 40 STCC 0.0286 0.0365 0.092 0.110 840 3 3 3 3 3 3 3 3 3 3 3 16 25 35 50 70 95 120 150 185 240 300 32 31 35 31 35 50 60 75 45 53 55 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.119 0.119 0.114 0.108 0.103 0.098 0.095 0.092 0.092 0.087 0.084 0.143 0.143 0.137 0.130 0.124 0.118 0.114 0.111 0.111 0.104 0.101 220 250 270 300 340 380 410 450 480 540 590 Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 96 127 157 196 242 293 339 389 444 522 601 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 67 89 110 137 169 205 237 272 311 365 421 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 56000 70000 88200 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 15 x D Subject to change without prior notice Minimum Bending Radius Fixed Installed 9xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 49 of 212 Halogen-free, mud resistant MV power cable, RFOU 8,7/15(17,5)kV, P4/P11 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 8,7/15(17,5) kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP4/P11 Operating temperature Operating Voltage : 90°C : 8,7/15(17,5) kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009 IEC 60092-354 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 04 RFOU 8,7/15(17,5)KV P4/P11 1 x 300/29 mm2 IEC 60332-3-22 DRAKA 04 = Draka Industrial Cable, Germany Red Page 50 of 212 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm 1 22 ± 1.0 0.4 35 1.8 0.4 27.1 1.8 0.4 27.1 1.9 0.4 27.1 1.9 0.4 31.7 2.0 0.4 31.7 2.0 31.0 ±1.5 0.4 31.7 2.1 0.4 31.7 2.2 0.4 36.2 2.3 25 20 6.5 4.5 1.0 1 35 20 7.4 4.5 1.0 1 50 20 8.8 4.5 1.0 1 70 20 10.3 4.5 1.0 1 95 20 12.1 4.5 1.2 1 120 20 13.6 4.5 1.2 1 150 20 15.1 4.5 1.2 23.0 ± 1.5 24.0 ± 1.5 26.0 ± 1.5 28.0 ± 1.5 29.5 ± 1.5 33.0 ± 1.5 35.0 ± 1.5 1 185 20 16.8 4.5 1.2 1 240 25 19.1 4.5 1.2 1 300 29 21.5 4.5 1.2 37.5 ±1.5 0.4 40.7 2.4 1 400 30 25.6 4.5 1.5 42 ± 2.0 0.4 49.8 2.6 3 25 35 6.5 4.5 1.4 0.5 35 2.7 3 35 35 7.4 4.5 1.6 3 50 40 8.8 4.5 1.6 3 70 40 10.3 4.5 1.6 3 95 55 12.1 4.5 1.6 3 120 60 13.6 4.5 1.6 3 150 80 15.1 4.5 1.8 3 185 95 16.8 4.5 1.8 3 240 95 19.1 4.5 1.8 3 300 95 21.5 4.5 1.8 46.5 ± 2.0 49.0 ± 2.0 52.0 ± 2.0 55.5 ± 2.5 59 ± 2.5 62.5 ± 2.5 66.0 ± 2.5 69.5 ± 2.5 74.5 ± 3.0 80.0 ± 3.0 0.5 49.5 2.8 0.5 56.5 2.9 0.5 56.5 3.1 0.5 70.7 3.2 0.5 84.8 3.4 0.6 112 3.5 0.6 122.1 3.7 0.6 122.1 3.9 0.6 122.1 4.0 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1370 733 1500 824 1700 978 2000 1204 2450 1500 2700 1766 3000 1793 3500 2424 42.0 ±2.5 4300 2996 28.0 ± 1.5 29.0 ± 1.5 30.5 ± 1.5 32.0 ± 1.5 34.5 ± 2.0 36.0 ± 2.0 38.0 ± 2.0 39.5 ± 2.5 44.5 ± 2.5 49.5 ± 2.5 55 ± 3.0 57.5 ± 3.0 61.0 ± 3.0 64.5 ± 3.0 68.5 ± 3.0 72 ± 3.5 76.0 ± 3.5 80.0 ± 4.0 85.5 ± 4.0 91.0 ± 4.0 5000 3612 6250 4772 4800 1864 5400 2152 6100 2667 7250 3344 8500 3998 9750 5166 11150 6321 13200 7606 15650 9114 17800 10420 Ordering information New Part number Old Part number 804501 804502 804503 804504 804505 804506 804507 804508 804509 Description Sheath Colour Stock item EAN No. DNK EL No. 804511 RFOU 8.7/15KV 1X 25/20mm² P4/P11 RFOU 8.7/15KV 1X 35/20mm² P4/P11 RFOU 8.7/15KV 1X 50/20mm² P4/P11 RFOU 8.7/15KV 1X 70/20mm² P4/P11 RFOU 8.7/15KV 1X 95/20mm² P4/P11 RFOU 8.7/15KV 1X 120/20mm² P4/P11 RFOU 8.7/15KV 1X150/20 P4/P11 RFOU 8.7/15KV 1X 185/20mm² P4/P11 RFOU 8.7/15KV 1X 240/25mm² P4/P11 RFOU 8.7/15KV 1X 300/29mm² P4/P11 RFOU 8.7/15KV 1X 400/30mm² P4/P11 RED RED RED RED RED RED RED RED RED RED RED - 7021528045017 7021528045024 7021528045031 7021528045048 7021528045055 7021528045062 7021528045079 7021528045086 7021528045093 7021528045109 7021528045116 - 804521 804522 804523 804524 804525 804526 804527 RFOU 8.7/15KV 3X 25/35mm² P4/P11 RFOU 8.7/15KV 3X 35/35mm² P4/P11 RFOU 8.7/15KV 3X 50/40mm² P4/P11 RFOU 8.7/15KV 3X 70/40mm² P4/P11 RFOU 8.7/15KV 3X 95/55mm² P4/P11 RFOU 8.7/15KV 3X 120/60mm² P4/P11 RFOU 8.7/15KV 3X 150/80mm² P4/P11 RED RED RED RED RED RED RED - 7021528045215 7021528045222 7021528045239 7021528045246 7021528045253 7021528045260 7021528045277 - 20076154 Subject to change without prior notice Page 51 of 212 New Part number Old Part Description number 804528 RFOU 8.7/15KV 3X 185/95mm² P4/P11 804529 RFOU 8.7/15KV 3X 240/95mm² P4/P11 804530 RFOU 8.7/15KV 3X 300/95mm² P4/P11 Sheath Colour Stock item RED RED RED - EAN No. DNK 7021528045284 7021528045291 7021528045307 EL No. - Electrical values power cables Number of elements Cross section core, mm² Electrical Conductor Max. Max. Cross type 2 conductor conductor section resistance at resistance at braid, mm² 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nF/km 1 1 1 1 1 1 1 1 1 1 25 35 50 70 95 120 150 185 240 300 20 20 20 20 20 20 20 20 25 29 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.151 0.145 0.137 0.130 0.125 0.120 0.116 0.113 0.109 0.105 0.181 0.174 0.165 0.156 0.150 0.144 0.140 0.135 0.130 0.126 210 230 250 280 310 340 370 400 440 480 1 400 30 STCC 0.047 0.059 0.101 0.121 550 3 3 3 3 3 3 3 3 3 3 25 35 50 70 95 120 150 185 240 300 35 35 40 40 55 60 80 95 95 95 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.127 0.122 0.115 0.109 0.104 0.100 0.097 0.097 0.091 0.088 0.152 0.146 0.138 0.131 0.125 0.121 0.117 0.117 0.109 0.106 210 230 250 280 310 340 370 400 440 480 Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 127 157 196 242 293 339 389 444 522 601 690 dc / 670 ac 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 89 110 137 169 205 237 272 311 365 421 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 56000 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 15 x D Subject to change without prior notice Minimum Bending Radius Fixed Installed 9xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 52 of 212 Halogen-free, mud resistant MV power cable, RFOU 12/20(24)kV, P19/P21 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 12/20(24) kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP19/P21 Operating temperature Operating Voltage : 90°C : 12/20(24) kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009 IEC 60092-354 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 04 RFOU 12/20(24)KV P19/P21 3 x 95/50 mm2 IEC 60332-3-22 DRAKA 04 = Draka Industrial Cable, Germany Red Page 53 of 212 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² 1 16 13 5.2 5.5 1.0 22.5 ±1.0 0.3 1 25 13 6.5 5.5 1.0 24 ±1.0 1 1 1 1 1 1 35 50 70 95 120 150 13 15 13 17 15 15 7.4 8.8 10.3 12.1 13.6 15.1 5.5 5.5 5.5 5.5 5.5 5.5 1.2 1.2 1.2 1.2 1.3 1.3 1 185 18 16.8 5.5 1 240 23 19.1 1 300 28 1 400 3 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 15.3 1.6 1200 495 0.3 15.3 1.7 1300 561 25 ±1.5 26.5 ±1.5 28 ± 1.5 30 ±1.5 31.5 ±1.5 33 ±1.5 0.3 0.3 0.3 0.3 0.3 0.3 15.3 17.8 15.3 20.4 17.8 17.8 1.8 2.0 2.1 2.1 2.1 2.2 1450 1700 2000 2400 2650 3000 671 811 1001 1210 1491 1835 1.4 35 ±1.5 0.3 20.4 2.2 3500 2201 5.5 1.4 37.5 ±1.5 0.3 25.4 2.4 4350 2915 21.5 5.5 1.4 41.0 ±2.0 0.3 30.5 2.6 5200 3640 35 35.0 5.5 1.5 44.8 ±2.0 0.3 40.0 2.6 28 ± 1.5 29.5 ± 1.5 31 ± 2 32.5 ± 2 34 ± 2.0 36 ± 2 38 ± 2 40 ± 2.5 41.5 ± 2.5 45.0 ± 2.5 47.0 ± 3.0 51.5 ± 3.0 6500 4400 16 31 5.2 5.5 1.4 48 ± 2.0 0.4 36.2 2.6 9300 4112 3 25 35 6.5 5.5 1.4 51 ± 2.0 0.4 40.7 2.7 4950 1558 3 35 35 7.4 5.5 1.4 0.4 40.7 2.8 5500 1885 3 50 35 8.8 5.5 1.8 53 ± 2.0 57.0 ± 2.0 0.4 40.7 3.0 6500 2276 3 70 35 10.3 5.5 1.8 60 ± 2.5 0.4 40.7 3.1 7500 2979 3 95 50 12.1 5.5 2.0 0.5 56.5 3.3 9300 4112 3 120 60 13.6 5.5 2.0 0.5 70.7 3.4 10250 4761 3 150 75 15.1 5.5 2.0 0.5 91.9 3.5 11700 5822 3 185 45 16.8 5.5 2.0 0.5 56.5 3.7 12950 6615 3 240 55 19.1 5.5 2.2 0.5 70.7 3.9 15900 8797 64.5 ± 3.0 67.5 ± 3.0 71.0 ± 3.0 75.0 ± 3.5 79.5 ± 3.5 55.5 ± 3.0 58.5 ± 3.0 61 ± 3.0 65.5 ± 3.5 68.5 ± 3.5 73.5 ± 4.0 77 ± 4.0 80.0 ± 4.5 85.0 ± 4.5 90.0 ± 4.5 Ordering information New Part number Old Part number 804100 804101 804102 804103 20076155 20076158 804106 20099891 20092205 20077821 20076160 804111 804120 804121 804122 804123 804124 804125 804126 804127 20077822 804129 Description Sheath Colour Stock item EAN No. DNK EL No. RFOU 12/20KV 1X 16/13mm² P19/P21 RFOU 12/20KV 1X 25/13mm² P19/P21 RFOU 12/20KV 1X 35/13mm² P19/P21 RFOU 12/20KV 1X 50/15mm² P19/P21 RFOU 12/20KV 1X 70/13mm² P19/P21 RFOU 12/20KV 1X 95/17mm² P19/P21 RFOU 12/20KV 1X120/15mm² P19/P21 RFOU 12/20KV 1X150/15mm² P19/P21 RFOU 12/20KV 1X185/18mm² P19/P21 RFOU 12/20KV 1X240/23mm² P19/P21 RFOU 12/20KV 1X300/28mm² P19/P21 RFOU 12/20KV 1X400/35mm² P19/P21 RED RED RED RED RED RED RED RED RED RED RED RED Yes Yes - 7021528041002 7021528041019 7021528041026 7021528041033 7021528041040 7021528041057 7021528041064 7021528041071 7021528041088 7021528041095 7021528041101 7021528041118 1061035 1061038 - RFOU 12/20KV 3X 16/31mm² P19/P21 RFOU 12/20KV 3X 25/35mm² P19/P21 RFOU 12/20KV 3X 35/35mm² P19/P21 RFOU 12/20KV 3X 50/35mm² P19/P21 RFOU 12/20KV 3X 70/35mm² P19/P21 RFOU 12/20KV 3X 95/50mm² P19/P21 RFOU 12/20KV 3X120/60mm² P19/P21 RFOU 12/20KV 3X150/75mm² P19/P21 RFOU 12/20kV 3X 185/45mm² P19/P21 RFOU 12/20KV 3X240/55mm² P19/P21 RED RED RED RED RED RED RED RED RED RED - 7021528041200 7021528041217 7021528041224 7021528041231 7021528041248 7021528041255 7021528041262 7021528041279 7021528041286 7021528041293 - Subject to change without prior notice Page 54 of 212 Electrical values power cables Number of elements Cross section core, mm² Electrical Conductor Max. Max. Cross type 2 conductor conductor section resistance at resistance at braid, mm² 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nF/km 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 13 13 13 15 13 17 15 15 18 23 28 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 0.0607 1.479 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.164 0.154 0.149 0.140 0.133 0.127 0.124 0.119 0.116 0.112 0.108 0.197 0.185 0.178 0.169 0.160 0.152 0.149 0.142 0.139 0.134 0.130 170 190 200 220 250 270 300 320 340 380 410 1 400 35 STCC 0,0475 0,0606 0.105 0.126 490 3 3 3 3 3 3 3 3 3 3 16 25 35 50 70 95 120 150 185 240 31 35 35 35 35 50 60 75 45 55 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 0.0762 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.143 0.133 0.128 0.121 0.115 0.109 0.105 0.102 0.099 0.095 0.172 0.160 0.153 0.145 0.135 0.131 0.126 0.122 0.118 0.114 170 190 200 220 250 270 300 320 340 380 Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 96 127 157 196 242 293 339 389 444 522 601 690 dc / 670 ac 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 67 89 110 137 169 205 237 272 311 365 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 56000 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 15 x D Subject to change without prior notice Minimum Bending Radius Fixed Installed 9xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 55 of 212 Halogen-free, mud resistant MV power cable, RFOU 18/30(36)kV, P20/P22 Flame retardant halogen-free medium voltage (MV) cable. Mud resistant RFOU 18/30(36) kV EPR/EPR/TCWB/EVA NEK 606 CodeP20/P22 Operating temperature Operating Voltage : 90°C : 18/30(36) kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. IEC 60092-354 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Conductor screen semiconductive Insulation Insulation screen semicoductive Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 04 RFOU 18/30(36)KV P20/P22 3x 120/60 mm2 IEC 60332-3-22 DRAKA 04 = Draka Industrial Cable, Germany Red Page 56 of 212 Range and dimensions Cross Cross Number Conductor Insulation section section of Diameter, Thickness, core, screen, elements mm mm mm² mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 1 1 1 1 1 1 50 70 95 120 150 185 240 300 25 30 30 20 30 30 40 35 8.8 10.3 12,1 13,6 15.1 16.8 19.1 21,5 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8,0 1,5 1,5 1,5 1.5 1,5 1.5 1,5 1,5 32.0±1.5 33,5±2,0 35,0±2.0 37.0±2.5 39,0±2.5 40.0±2.5 42.0±2.5 45,0±2,5 0.4 0,4 0,4 0.4 0,4 0.4 0.4 0,4 36.2 36.2 40.7 40.7 45.2 49.8 49.8 54.3 2.0 2,2 2,2 2.4 2,3 2.5 2.4 2,6 38.5±2.0 40,0±3.0 42,0±3.0 44.0±3.0 45,5±3.0 47.5±3.0 50.0±3.0 53,0+-3,5 2500 3000 3400 3500 3900 4600 5400 6200 1119 1463 1698 1939 2280 2675 3250 3867 3 3 3 3 35 70 95 120 45 85 90 95 7.4 10.3 12.1 13.6 8.0 8.0 8.0 8.0 1,8 1,8 1.8 2,0 65.0±2.5 70.0±2.5 74.0±2.5 78.0±2.5 0,6 0,6 0.6 0,6 112 122 122 122 3.5 3,7 3.6 3.8 74.5±3.5 80.5±3.5 85.0±3.5 88,0±4,0 7750 10500 11850 13000 2879 4244 5088 5403 Ordering information New Part number Old Part number 804303 804304 804305 20099892 804307 804308 804309 20077940 804322 804324 804325 804326 Description Sheath Colour Stock item EAN No. DNK EL No. RFOU 18/30KV 1x 50/25mm² P20/P22 RFOU 18/30KV 1x 70/30mm² P20/P22 RFOU 18/30KV 1x 95/30mm² P20/P22 RFOU 18/30KV 1x 120/20mm² P20/P22 RFOU 18/30KV 1x 150/ 30mm² P20/P22 RFOU 18/30KV 1x 185/ 30mm² P20/P22 RFOU 18/30KV 1x 240/40mm² P20/P22 RFOU 18/30KV 1x 300/35mm² P20/P22 RED RED RED RED RED RED RED RED - 7021528043037 7021528043044 7021528043051 7021528043068 7021528043075 7021528043082 7021528043099 7021528043105 - RFOU 18/30KV 3x 35/45mm² P20/P22 RFOU 18/30KV 3x 70/85mm² P20/P22 RFOU 18/30KV 3x 95/90mm² P20/P22 RFOU 18/30KV 3x 120/95mm² P20/P22 RED RED RED RED - 7021528043228 7021528043242 7021528043259 7021528043266 - Electrical values power cables Number of Cross elements section core, mm² Cross section screen, mm² Conductor type 2 Max. Max. conductor conductor resistance at resistance at 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Capacitans per phase, nF/km Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 1 1 1 1 1 1 1 1 50 70 95 120 150 185 240 300 25 30 30 20 30 30 40 35 STCC STCC STCC STCC STCC STCC STCC STCC 0.391 0.270 0.195 0.154 0.126 0.097 0,0762 0.0607 0.499 0.344 0.249 0.193 0.161 0.122 0,0972 0.0774 0.152 0.145 0.138 0.133 0,129 0.125 0.120 0.115 0.182 0.174 0.165 0.160 0,154 0.149 0.143 0.135 180 190 210 190 250 265 290 270 196 242 293 339 389 444 522 601 7000 9800 13300 16800 21000 25900 33600 42000 3 3 3 3 35 70 95 120 45 85 90 95 STCC STCC STCC STCC 0.529 0.270 0.195 0.154 0.675 0.344 0.249 0.196 0.141 0,126 0.117 0.115 0.170 0,151 0.141 0.135 160 190 180 230 110 169 205 237 4900 9800 13300 16800 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 15 x D Subject to change without prior notice Minimum Bending Radius Fixed Installed 9xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 57 of 212 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 Fire resistant, flame retardant halogen-free power cable. Mud resistant BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application IEC 60092-353 Fixed installation for power, control and lighting in both IEC 60228 class 2 IEC 60092-360 EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance IEC 60092-360 IEC 60332-1-2 exists. For installation in areas exposed to MUD and IEC 60332-3-22 drilling/cleaning fluids. Meets the MUD resistance IEC 60331-1, -2, -21 requirement in NEK TS 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Black Marking text Manufacturing unit Outer sheath colour *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 58 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 1 16 4 5.15 1.0 1.1 0.2 1 25 6 6.45 1.2 1.1 10 ± 0.8 11.5 ± 0.8 1 35 6 7.65 1.2 1.1 1 50 10 9.0 1.4 1.1 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 5.3 1.2 370 198 0.3 8.5 1.3 530 314 13 ± 0.8 0.3 10.2 1.3 660 413 15 ± 0.8 0.3 12.7 1.4 13 ± 0.8 15.5 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 870 559 0.3 12.7 1.4 20.5 ± 1 1120 756 0.3 15.3 1.5 23 ± 1 1430 996 0.3 0.3 0.3 0.3 15.3 17.8 17.8 20.4 1.6 1.7 1.7 1.8 25 ± 1 27.5 ± 1 29.5 ± 1 33 ± 1.5 1730 2120 2500 3150 1231 1535 1839 2365 0.3 22.9 1.9 36 ± 1.5 3890 2984 10 ± 0.8 10.5 ± 0.8 11.5 ± 0.8 0.2 5.3 1.2 80 8.5 1.3 360 125 0.3 10.2 1.3 13 ± 0.8 14.5 ± 0.8 15.5 ± 0.8 16.5 ± 0.8 17 ± 0.8 21.5 ± 1 25 ± 1 29 ± 1 31.5 ± 1.5 32.5 ± 1.5 285 0.3 410 156 480 170 540 800 1090 1440 215 318 440 577 1740 671 1860 741 360 125 410 156 480 170 16.5 ± 0.8 18.5 ± 0.8 20.5 ± 1 23 ± 1 25 ± 1 28 ± 1 30.5 ± 1.5 1 70 10 10.85 1.4 1.1 1 95 10 12.60 1.6 1.1 1 1 1 1 120 150 185 240 10 10 10 16 14.20 15.90 17.70 20.15 1.6 1.8 2.0 2.2 1.2 1.2 1.2 1.2 1 300 16 22.60 2.4 1.2 2 1.5 4 1.6 1.0 1.1 3 1.5 6 1.6 1.0 1.1 4 1.5 6 1.6 1.0 1.1 5 1.5 6 1.6 1.0 1.1 13 ± 0.8 0.3 10.2 1.4 7 12 19 27 1.5 1.5 1.5 1.5 6 10 10 16 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.1 1.2 1.2 1.2 13 ± 0.8 17 ± 0.8 20.5 ± 1 24 ± 1 0.3 0.3 0.3 0.3 11.9 15.3 17.8 20.4 1.4 1.6 1.7 1.9 32 1.5 16 1.6 1.0 1.4 26.5 ± 1 0.3 22.9 2 37 1.5 16 1.6 1.0 1.4 27.5 ± 1 0.3 22.9 2 3G 1.5 - 1.6 1.0 1.1 0.3 8.5 1.3 4G 1.5 - 1.6 1.0 1.1 0.3 10.2 1.3 5G 1.5 - 1.6 1.0 1.1 13 ± 0.8 0.3 10.2 1.4 2 2.5 6 2.0 1.0 1.1 11 ± 0.8 0.3 8.5 1.3 14.5 ± 0.8 370 129 0.3 10.2 1.3 15 ± 0.8 420 169 0.3 10.2 1.3 480 192 0.3 0.3 0.3 0.3 0.3 11.9 11.9 17.8 20.4 22.9 1.4 1.4 1.6 1.8 2 570 630 990 1370 1860 231 277 450 636 844 0.4 36.2 2.2 2510 1204 3 2.5 6 2.0 1.0 1.1 4 2.5 6 2.0 1.0 1.1 5 7 12 19 27 2.5 2.5 2.5 2.5 2.5 6 6 10 16 16 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.4 37 2.5 25 2.0 1.0 1.4 Subject to change without prior notice 10.5 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 12.5 ± 0.8 14 ± 0.8 14 ± 0.8 19 ± 0.8 22.5 ± 1 27 ± 1 30.5 ± 1.5 14.5 ± 0.8 15.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 18 ± 0.8 18 ± 0.8 23 ± 1 27 ± 1 32 ± 1.5 36.5 ± 1.5 Page 59 of 212 Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² 3G 2.5 - 2.0 1.0 1.1 4G 2.5 - 2.0 1.0 1.1 5G 7G 2.5 2.5 - 2.0 2.0 1.0 1.0 1.1 1.1 8G 2.5 - 2.0 1.0 1.1 2 4 6 2.55 1.0 1.1 3 4 6 2.55 1.0 4 4 6 2.55 5 4 6 3G 4 4G 5G Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 11.5 ± 0.8 12.5 ± 0.8 14 ± 0.8 14 ± 0.8 19.5 ± 0.8 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 15 ± 0.8 420 169 0.3 10.2 1.3 0.3 10.2 1.3 0.3 0.3 11.9 11.9 0.3 12 ± 0.8 1.1 1.0 1.1 2.55 1.0 1.1 - 2.55 1.0 4 - 2.55 4 - 2.55 2 3 6 6 6 6 4 6 3G 480 192 1.4 1.4 16.5 ± 0.8 18 ± 0.8 18 ± 0.8 570 630 231 277 15.3 1.5 23.5 ± 1 790 333 0.3 10.2 1.3 450 173 13 ± 0.8 0.3 10.2 1.3 510 210 14 ± 0.8 15.5 ± 0.8 0.3 11.9 1.4 610 263 0.3 11.9 1.4 690 300 1.1 13 ± 0.8 0.3 10.2 1.3 510 210 1.0 1.1 11.9 1.4 610 263 1.1 14 ± 0.8 15.5 ± 0.8 0.3 1.0 0.3 11.9 1.4 690 300 3.15 3.15 1.0 1.0 1.1 1.1 0.3 0.3 10.2 11.9 1.4 1.4 209 281 3.15 1.0 1.1 0.3 11.9 1.4 17 ± 0.8 18 ± 0.8 19.5 ± 0.8 530 630 6 13 ± 0.8 14 ± 0.8 15.5 ± 0.8 720 335 6 - 3.15 1.0 1.1 0.3 11.9 1.4 281 6 - 3.15 1.0 1.1 0.3 11.9 1.4 720 335 5G 6 - 3.15 1.0 1.1 0.3 13.6 1.5 18 ± 0.8 19.5 ± 0.8 21.5 ± 1 630 4G 14 ± 0.8 15.5 ± 0.8 17 ± 0.8 880 406 2 3 4 10 10 10 10 10 10 4.05 4.05 4.05 1.0 1.0 1.0 1.1 1.1 1.1 15 ± 0.8 16 ± 0.8 18 ± 0.8 0.3 0.3 0.3 11.9 11.9 13.6 1.4 1.5 1.5 19 ± 0.8 20 ± 1 22 ± 1 690 810 970 299 390 496 3G 4G 5G 10 10 10 - 4.05 4.05 4.05 1.0 1.0 1.0 1.1 1.1 1.2 16 ± 0.8 18 ± 0.8 20 ± 1 0.3 0.3 0.3 11.9 13.6 15.3 1.5 1.5 1.6 20 ± 1 22 ± 1 24 ± 1 810 970 1180 388 496 603 2 16 16 5.15 1.0 1.1 0.5 21.2 1.5 22 ± 1 990 501 3 16 16 5.15 1.0 1.1 4 5 16 16 16 16 5.15 5.15 1.0 1.0 1.2 1.2 3G 16 - 5.15 1.0 1.1 4G 5G 16 16 - 5.15 5.15 1.0 1.0 2 3 4 25 25 25 16 16 16 6.45 6.45 6.45 3G 4G 5G 25 25 25 - 2 3 4 35 35 35 3G 4G 5G 15.5 ± 0.8 16.5 ± 0.8 18 ± 0.8 19.5 ± 0.8 16.5 ± 0.8 18 ± 0.8 19.5 ± 0.8 17.5 ± 0.8 18.5 ± 0.8 20.5 ± 1 23 ± 1 0.4 22.6 1.5 23 ± 1 1170 660 0.4 0.3 22.6 20.4 1.6 1.7 25.5 ± 1 27.5 ± 1 1410 1640 806 930 0.3 15.3 1.5 22.5 ± 1 1090 588 1.2 1.2 18.5 ± 0.8 20.5 ± 1 23 ± 1 0.3 0.3 15.3 17.8 1.6 1.7 25 ± 1 27.5 ± 1 1330 1610 734 905 1.2 1.2 1.2 1.2 1.2 1.2 21 ± 1 22.5 ± 1 25 ± 1 0.4 0.3 0.3 22.6 20.4 20.4 1.6 1.7 1.8 26 ± 1 27 ± 1 29.5 ± 1 1370 1600 1960 685 894 1125 6.45 6.45 6.45 1.2 1.2 1.2 1.2 1.2 1.2 22.5 ± 1 25 ± 1 27.5 ± 1 0.3 0.3 0.3 17.8 17.8 20.4 1.7 1.8 1.8 27 ± 1 29.5 ± 1 32 ± 1.5 1580 1930 2290 869 1100 1356 16 16 16 7.65 7.65 7.65 1.2 1.2 1.2 1.2 1.2 1.2 23.5 ± 1 25 ± 1 28 ± 1 0.3 0.3 0.3 20.4 20.4 20.4 1.7 1.8 1.9 28 ± 1 30 ± 1.5 33 ± 1.5 1640 2000 2460 828 1142 1456 35 35 - 7.65 7.65 1.2 1.2 1.2 1.2 25 ± 1 28 ± 1 0.3 0.3 17.8 20.4 1.8 1.9 1980 2460 1117 1456 35 - 7.65 1.2 1.4 31 ± 1.5 0.3 22.9 2 30 ± 1.5 33 ± 1.5 36.5 ± 1.5 3000 1795 Subject to change without prior notice Page 60 of 212 Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm 2 50 25 9.0 1.4 1.4 27.5 ± 1 0.4 31.7 1.8 3 50 25 9.0 1.4 1.2 29 ± 1 0.4 31.7 1.9 4 50 25 9.0 1.4 1.4 32.5 ± 1.5 0.4 31.7 2 3G 50 - 9.0 1.4 1.2 0.3 22.9 4G 50 - 9.0 1.4 1.4 0.3 5G 50 - 9.0 1.4 1.4 2 70 35 10.85 1.4 1.6 3 70 35 10.85 1.4 1.4 4 70 35 10.85 1.4 1.4 3G 70 - 10.85 1.4 1.4 4G 5G 70 70 - 10.85 10.85 1.4 1.4 3 4 95 95 50 50 12.60 12.60 3G 4G 5G 95 95 95 - 3 120 4 120 4G 29 ± 1 32.5 ± 1.5 36 ± 1.5 31.5 ± 1.5 33.5 ± 1.5 37 ± 1.5 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 2270 1181 2730 1617 38 ± 1.5 3370 2052 1.9 34 ± 1.5 2640 1531 22.9 2 38 ± 1.5 3280 1968 0.4 36.2 2.2 42 ± 2 4110 2531 0.6 50.9 2 38 ± 1.5 3190 1783 32.5 ± 1.5 34.5 ± 1.5 0.5 49.5 2 39 ± 1.5 3760 2386 0.4 45.2 2.2 43 ± 2 4600 2977 3520 2150 4510 5440 2888 3566 0.3 25.4 2 1.4 1.4 33.5 ± 1.5 37 ± 1.5 41 ± 2 0.4 0.4 36.2 40.7 2.2 2.3 38.5 ± 1.5 43 ± 2 47 ± 2 1.6 1.6 1.4 1.6 38 ± 1.5 42.5 ± 2 0.6 0.5 61.1 63.6 2.2 2.4 44.5 ± 2 49.5 ± 2 4930 6130 3169 4022 12.60 12.60 12.60 1.6 1.6 1.6 1.4 1.6 1.6 38 ± 1.5 42.5 ± 2 47 ± 2 0.4 0.4 0.4 36.2 40.7 45.2 2.2 2.4 2.6 44 ± 2 49 ± 2 54 ± 2.5 4640 5890 7130 2901 3794 4688 60 14.20 1.6 1.4 41.5 ± 2 0.6 71.3 2.4 3976 14.20 1.6 1.6 46.5 ± 2 0.6 71.3 2.5 48.5 ± 2 53.5 ± 2.5 6020 60 7460 5060 120 - 14.20 1.6 1.6 46.5 ± 2 0.4 45.2 2.5 53 ± 2.5 7170 4781 4G 150 - 15.90 1.8 1.6 52 ± 2.5 0.5 49.5 2.7 5G 150 - 15.90 1.8 1.8 58 ± 2.5 0.5 63.6 4G 185 - 17.70 2.0 1.8 57.5 ± 2.5 0.5 56.5 8900 5943 2.9 59.5 ± 2.5 66 ± 3 10900 7450 2.9 65.5 ± 3 10830 7251 Ordering information New Part number Old Part number 20120052 20110496 800202 20110497 20110498 20110499 20110500 20110501 20110502 20110503 20109432 20110504 20110507 20110508 20110509 20110510 20109433 20110511 20110512 800227 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU 0.6/1kV 1X 16/4mm² P5/P12 BFOU 0.6/1kV 1X 25/6mm² P5/P12 BFOU 0.6/1kV 1X 35/6mm² P5/P12 BFOU 0.6/1kV 1X 50/10 P5/P12 BFOU 0.6/1kV 1X 70/10 P5/P12 BFOU 0.6/1kV 1X 95/10 P5/P12 BFOU 0.6/1kV 1X 120/10 P5/P12 BFOU 0.6/1kV 1X 150/10 P5/P12 BFOU 0.6/1kV 1X 185/10 P5/P12 BFOU 0.6/1kV 1X 240/16 P5/P12 BFOU 0.6/1kV 1X 300/16 P5/P12 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes Yes Yes Yes Yes 7021528002003 7021528002010 7021528002027 7021528002034 7021528002041 7021528002058 7021528002065 7021528002072 7021528002089 7021528002096 7021528002102 1043605 1043608 1043609 1043610 1043611 1043612 1043613 1043615 BFOU 0.6/1kV 2X 1.5/4 P5/P12 BFOU 0.6/1kV 3X 1.5/6 P5/P12 BFOU 0.6/1kV 4X 1.5/6 P5/P12 BFOU 0.6/1kV 5X 1.5/6 P5/P12 BFOU 0.6/1kV 7X 1.5/6 P5/P12 BFOU 0.6/1kV 12X 1.5/10 P5/P12 BFOU 0.6/1kV 19X 1.5/10 P5/P12 BFOU 0.6/1kV 27X 1.5/16 P5/P12 BFOU 0.6/1kV 32X 1.5/16 P5/P12 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes Yes Yes Yes Yes Yes - 7021528002157 7021528002188 7021528002195 7021528002201 7021528002218 7021528002225 7021528002232 7021528002249 7021528002270 1043620 1043640 1043660 1043705 1043707 1043712 1043719 1043727 - Subject to change without prior notice Page 61 of 212 New Part number 20109434 Old Part number BFOU 0.6/1kV 37X 1.5/16 P5/P12 Sheath Colour BLACK - 7021528002256 1043737 20110505 20110506 20110513 BFOU 0.6/1kV 3G 1.5mm² P5/P12 BFOU 0.6/1kV 4G 1.5mm² P5/P12 BFOU 0.6/1kV 5G 1.5mm² P5/P12 BLACK BLACK BLACK - 7021528002164 1043619 7021528002171 7021528002263 - 20110515 20110517 20110519 20121182 20110520 20110521 20110522 20112294 20109435 BFOU 0.6/1kV 2X 2.5/6 P5/P12 BFOU 0.6/1kV 3X 2.5/6 P5/P12 BFOU 0.6/1kV 4X 2.5/6 P5/P12 BFOU 0.6/1kV 5X 2.5/6 P5/P12 BFOU 0.6/1kV 7X 2.5/6 P5/P12 BFOU 0.6/1kV 12X 2.5/10 P5/P12 BFOU 0.6/1kV 19X 2.5/16 P5/P12 BFOU 0.6/1kV 27X 2.5/16 P5/P12 BFOU 0.6/1kV 37X 2.5/25 P5/P12 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes Yes Yes Yes - 7021528002294 7021528002324 7021528002355 7021528002348 7021528002379 7021528002386 7021528002393 7021528002409 7021528002416 1043621 1043641 1043661 1043757 1043762 1043769 1043777 1043787 20110516 20110518 20110523 20110514 BFOU 0.6/1kV 3G 2.5mm² P5/P12 BFOU 0.6/1kV 4G 2.5mm² P5/P12 BFOU 0.6/1kV 5G 2.5mm² P5/P12 BFOU 0.6/1kV 7G 2.5mm² P5/P12 BFOU 0.6/1kV 8G 2.5mm² P5/P12 BLACK BLACK BLACK BLACK BLACK Yes Yes - 7021528002300 7021528002331 7021528002423 7021528002287 7021528002362 1043639 1043659 1043755 - 20110526 20110527 20110528 20110529 BFOU 0.6/1kV 2X 4/6mm² P5/P12 BFOU 0.6/1kV 3X 4/6mm² P5/P12 BFOU 0.6/1kV 4X 4/6mm² P5/P12 BFOU 0.6/1kV 5X 4/6mm² P5/P12 BLACK BLACK BLACK BLACK Yes Yes Yes - 7021528002454 7021528002461 7021528002478 7021528002485 1043622 1043642 1043662 - 20110529 20110524 20110525 BFOU 0.6/1kV 3G 4mm² P5/P12 BFOU 0.6/1kV 4G 4mm² P5/P12 BFOU 0.6/1kV 5G 4mm² P5/P12 BLACK BLACK BLACK Yes - 7021528002508 7021528002430 7021528002447 - 20110530 20110531 20110532 BFOU 0.6/1kV 2X 6/6mm² P5/P12 BFOU 0.6/1kV 3X 6/6mm² P5/P12 BFOU 0.6/1kV 4X 6/6mm² P5/P12 BLACK BLACK BLACK Yes Yes Yes 7021528002515 1043623 7021528002522 1043643 7021528002539 1043663 20110533 20110534 20110535 BFOU 0.6/1kV 3G 6mm² P5/P12 BFOU 0.6/1kV 4G 6mm² P5/P12 BFOU 0.6/1kV 5G 6mm² P5/P12 BLACK BLACK BLACK Yes - 7021528002546 7021528002553 7021528002560 - 20110536 20110537 20110538 BFOU 0.6/1kV 2X 10/10 P5/P12 BFOU 0.6/1kV 3X 10/10 P5/P12 BFOU 0.6/1kV 4X 10/10 P5/P12 BLACK BLACK BLACK Yes Yes Yes 7021528002577 1043624 7021528002584 1043644 7021528002591 1043664 20110539 20110540 20110541 BFOU 0.6/1kV 3G 10mm² P5/P12 BFOU 0.6/1kV 4G 10mm² P5/P12 BFOU 0.6/1kV 5G 10mm² P5/P12 BLACK BLACK BLACK - 7021528002607 7021528002614 7021528002621 - 20109436 20110542 20110543 BFOU 0.6/1kV 2X 16/16 P5/P12 BFOU 0.6/1kV 3X 16/16 P5/P12 BFOU 0.6/1kV 4X 16/16 P5/P12 BFOU 0.6/1kV 5X 16/16 P5/P12 BLACK BLACK BLACK BLACK Yes Yes Yes - 7021528002638 7021528002645 7021528002652 7021528003161 20110544 20110546 20110545 BFOU 0.6/1kV 3G 16mm² P5/P12 BFOU 0.6/1kV 4G 16mm² P5/P12 BFOU 0.6/1kV 5G 16mm² P5/P12 BLACK BLACK BLACK - 7021528002669 7021528002683 7021528002676 - 20110547 20110548 20110549 BFOU 0.6/1kV 2X 25/16 P5/P12 BFOU 0.6/1kV 3X 25/16 P5/P12 BFOU 0.6/1kV 4X 25/16 P5/P12 BLACK BLACK BLACK Yes Yes 7021528002690 1043626 7021528002706 1043646 7021528002713 1043666 BFOU 0.6/1kV 3G 25mm² P5/P12 BFOU 0.6/1kV 4G 25mm² P5/P12 BFOU 0.6/1kV 5G 25mm² P5/P12 BLACK BLACK BLACK - 7021528002744 7021528002720 7021528002737 - BFOU 0.6/1kV 2X 35/16 P5/P12 BFOU 0.6/1kV 3X 35/16 P5/P12 BFOU 0.6/1kV 4X 35/16 P5/P12 BLACK BLACK BLACK Yes Yes 7021528002751 1043627 7021528002768 1043647 7021528002775 1043667 BFOU 0.6/1kV 3G 35mm² P5/P12 BFOU 0.6/1kV 4G 35mm² P5/P12 BFOU 0.6/1kV 5G 35mm² P5/P12 BLACK BLACK BLACK - 7021528002782 7021528002799 7021528002805 - 800236 800316 800274 800272 800273 20110762 20110550 20110551 800278 800279 20110763 Description Subject to change without prior notice Stock item EAN No. DNK EL No. 1043625 1043645 1043665 - Page 62 of 212 New Part number 20121221 20110552 20110553 Old Part number BFOU 0.6/1kV 2X 50/25 P5/P12 BFOU 0.6/1kV 3X 50/25 P5/P12 BFOU 0.6/1kV 4X 50/25 P5/P12 Sheath Colour BLACK BLACK BLACK Yes - 7021528002812 7021528002829 1043648 7021528002836 1043668 BFOU 0.6/1kV 3G 50mm² P5/P12 BFOU 0.6/1kV 4G 50mm² P5/P12 BFOU 0.6/1kV 5G 50mm² P5/P12 BLACK BLACK BLACK - 7021528002867 7021528002850 7021528002843 - BFOU 0.6/1kV 2X 70/35 P5/P12 BFOU 0.6/1kV 3X 70/35 P5/P12 BFOU 0.6/1kV 4X 70/35 P5/P12 BFOU 0.6/1kV 5X 70/35 P5/P12 BLACK BLACK BLACK BLACK Yes - 7021528002874 7021528002881 7021528002898 7021528002935 BFOU 0.6/1kV 3G 70mm² P5/P12 BFOU 0.6/1kV 4G 70mm² P5/P12 BFOU 0.6/1kV 5G 70mm² P5/P12 BLACK BLACK BLACK - 7021528002928 7021528002904 7021528002911 - BFOU 0.6/1kV 2X 95/50 P5/P12 BFOU 0.6/1kV 3X 95/50 P5/P12 BFOU 0.6/1kV 4X 95/50 P5/P12 BLACK BLACK BLACK Yes Yes 7021528002942 7021528002959 1043650 7021528002966 1043670 20110764 20109442 BFOU 0.6/1kV 3G 95mm² P5/P12 BFOU 0.6/1kV 4G 95mm² P5/P12 BFOU 0.6/1kV 5G 95mm² P5/P12 BLACK BLACK BLACK - 7021528002997 7021528002973 7021528002980 - 20109443 20120715 BFOU 0.6/1kV 3X 120/60 P5/P12 BFOU 0.6/1kV 4X 120/60 P5/P12 BLACK BLACK Yes - 7021528003017 1043651 7021528003048 - 800306 BFOU 0.6/1kV 4G 120mm² P5/P12 BLACK - 7021528003062 - 800307 20132888 BFOU 0.6/1kV 4G 150mm² P5/P12 BFOU 0.6/1kV 5G 150mm² P5/P12 BLACK BLACK - 7021528003079 7021528003185 - 20121096 BFOU 0.6/1kV 4G 185mm² P5/P12 BLACK - 7021528003109 - 800286 800285 800284 20110554 20109437 20109438 20109439 800292 800290 800291 20115558 20109440 20109441 800299 Description Stock item EAN No. DNK EL No. 1043629 1043649 1043669 - Electrical values power cables Number of elements Cross Electrical Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit section Cross type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 core, section braid, 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, second, mm² mm² Ampere Ampere 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 4 6 6 10 10 10 10 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.118 0.114 0.108 0.105 0.1 0.097 0.095 0.094 0.092 0.09 0.088 0.142 0.136 0.129 0.126 0.12 0.116 0.114 0.112 0.11 0.108 0.106 96 127 157 196 242 293 339 389 444 522 601 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 2 3 4 5 7 12 19 27 32 37 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 4 6 6 6 6 10 10 16 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.138 20 16 16 13.5 12 10 8.5 7.5 7 7 210 210 210 210 210 210 210 210 210 210 3G 4G 5G 1.5 1.5 1.5 - STCC STCC STCC 12.2 12.2 12.2 15.6 15.6 15.6 0.115 0.115 0.115 0.138 0.138 0.138 20 16 16 210 210 210 2 3 2.5 2.5 6 6 STCC STCC 7.56 7.56 9.64 9.64 0.107 0.107 0.129 0.129 26 21 350 350 Subject to change without prior notice Page 63 of 212 Number of elements 5 4 7 12 19 27 37 Cross section core, mm² 2.5 2.5 2.5 2.5 2.5 2.5 2.5 Electrical Conductor Cross type 2 section braid, mm² 6 STCC 6 STCC 6 STCC 10 STCC 16 STCC 16 STCC 25 STCC Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, second, Ampere Ampere 7.56 9.64 0.107 0.129 17.5 350 7.56 9.64 0.107 0.129 21 350 7.56 9.64 0.107 0.129 15.5 350 7.56 9.64 0.107 0.129 13 350 7.56 9.64 0.107 0.129 11 350 7.56 9.64 0.107 0.129 10 350 7.56 9.64 0.107 0.129 9 350 3G 4G 5G 7G 8G 2.5 2.5 2.5 2.5 2.5 - STCC STCC STCC STCC STCC 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 9.64 0.107 0.107 0.107 0.107 0.107 0.129 0.129 0.129 0.129 0.129 26 21 21 16.5 15.5 350 350 350 350 350 2 3 4 5 4 4 4 4 6 6 6 6 STCC STCC STCC STCC 4.7 4.7 4.7 4.7 5.99 5.99 5.99 5.99 0.100 0.100 0.1 0.1 0.120 0.120 0.120 0.120 34 28 28 23.5 560 560 560 560 3G 4G 5G 4 4 4 - STCC STCC STCC 4.7 4.7 4.7 5.99 5.99 5.99 0.1 0.1 0.1 0.120 0.120 0.120 34 28 28 560 560 560 2 3 4 6 6 6 6 6 6 STCC STCC STCC 3.11 3.11 3.11 3.97 3.97 3.97 0.094 0.094 0.094 0.112 0.112 0.112 44 36 36 840 840 840 3G 4G 5G 6 6 6 - STCC STCC STCC 3.11 3.11 3.11 3.97 3.97 3.97 0.094 0.094 0.094 0.112 0.112 0.112 44 36 36 840 840 840 2 3 4 10 10 10 10 10 10 STCC STCC STCC 1.84 1.84 1.84 2.35 2.35 2.35 0.088 0.088 0.088 0.105 0.105 0.105 61 50 50 1400 1400 1400 3G 4G 5G 10 10 10 - STCC STCC STCC 1.84 1.84 1.84 2.35 2.35 2.35 0.088 0.088 0.088 0.105 0.105 0.105 61 50 50 1400 1400 1400 2 3 4 5 16 16 16 16 16 16 16 16 STCC STCC STCC STCC 1.16 1.16 1.16 1.16 1.48 1.48 1.48 1.48 0.082 0.082 0.082 0.082 0.099 0.099 0.099 0.099 80 67 67 56 2240 2240 2240 2240 3G 4G 5G 16 16 16 - STCC STCC STCC 1.16 1.16 1.16 1.48 1.48 1.48 0.082 0.082 0.082 0.099 0.099 0.099 80 67 67 2240 2240 2240 2 3 4 25 25 25 16 16 16 STCC STCC STCC 0.734 0.734 0.734 0.936 0.936 0.936 0.081 0.081 0.081 0.098 0.098 0.098 108 89 89 3500 3500 3500 3G 4G 5G 25 25 25 - STCC STCC STCC 0.734 0.734 0.734 0.936 0.936 0.936 0.081 0.081 0.081 0.098 0.098 0.098 108 89 89 3500 3500 3500 2 3 4 35 35 35 16 16 16 STCC STCC STCC 0.529 0.529 0.529 0.675 0.675 0.675 0.078 0.078 0.078 0.094 0.094 0.094 133 110 110 4900 4900 4900 3G 4G 5G 35 35 35 - STCC STCC STCC 0.529 0.529 0.529 0.675 0.675 0.675 0.078 0.078 0.078 0.094 0.094 0.094 133 110 110 4900 4900 4900 2 3 4 50 50 50 25 25 25 STCC STCC STCC 0.391 0.391 0.391 0.499 0.499 0.499 0.078 0.078 0.078 0.094 0.093 0.093 167 137 137 7000 7000 7000 3G 4G 50 50 - STCC STCC 0.391 0.391 0.499 0.499 0.078 0.078 0.093 0.093 167 137 7000 7000 Subject to change without prior notice Page 64 of 212 Number of elements 5G Cross Electrical Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit section Cross type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 core, section braid, 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, second, mm² mm² Ampere Ampere 50 STCC 0.391 0.499 0.078 0.093 137 7000 2 3 4 70 70 70 35 35 35 STCC STCC STCC 0.27 0.27 0.27 0.344 0.344 0.344 0.075 0.077 0.077 0.092 0.092 0.092 206 169 169 9800 9800 9800 3G 4G 5G 70 70 70 - STCC STCC STCC 0.27 0.27 0.27 0.344 0.344 0.344 0.075 0.075 0.075 0.092 0.092 0.092 206 169 169 9800 9800 9800 3 4 95 95 50 50 STCC STCC 0.195 0.195 0.249 0.249 0.075 0.075 0.090 0.090 205 205 13300 13300 3G 4G 5G 95 95 95 - STCC STCC STCC 0.195 0.195 0.195 0.249 0.249 0.249 0.075 0.075 0.075 0.090 0.090 0.090 249 205 205 13300 13300 13300 3 4 120 120 60 60 STCC STCC 0.154 0.154 0.196 0.196 0.073 0.073 0.088 0.088 237 237 16800 16800 4G 120 - STCC 0.154 0.196 0.073 0.088 237 16800 4G 150 - STCC 0.126 0.161 0.073 0.088 272 21000 4G 185 - STCC 0.1 0.128 0.073 0.088 311 25900 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 65 of 212 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided Fire resistant, flame retardant halogen-free power cable. Mud resistant. Double braided. BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application IEC 60092-353 Fixed installation for power, control and lighting in both IEC 60228 class 2 IEC 60092-360 EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance IEC 60092-360 IEC 60332-1-2 exists. For installation in areas exposed to MUD and IEC 60332-3-22 drilling/cleaning fluids. Meets the MUD resistance IEC 60331-1, -2, -21 requirement in NEK TS 606:2009. IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape + rubberized Polyamide tape O Two layers of tinned copper wire braid (double braid) PET tape + rubberized Polyamide tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Black Marking text Manufacturing unit Outer sheath colour *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 66 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 2 150 75 18.1 1.8 1.8 44 ± 2 0.4 90.5 2.5 5390 3622 3 150 75 15.90 1.8 1.4 46.5 ± 2 0.4 86 2.6 7510 4992 4 150 75 15.90 1.8 1.6 52 ± 2.5 0.5 99 2.8 52 ± 2.5 54.5 ± 2.5 61 ± 3 9470 6451 3 185 95 17.70 2.0 1.6 0.5 127.2 2.8 60.5 ± 3 9350 6295 4 185 95 17.7 2.0 1.8 51 ± 2.5 57.5 ± 2.5 0.6 122.1 2.9 68±3 11620 7750 2 3 240 240 120 120 20.2 20.2 2.2 2.2 1.8 1.8 54 ± 2.5 58 ± 2.5 0.6 0.6 142.5 142.5 2.9 3 64 ± 3 68.5 ± 3 9110 11870 5845 8042 Ordering information New Part number Old Part number 800317 Description Sheath Colour Stock item EAN No. DNK EL No. 20109444 20117948 BFOU 0.6/1kV 2X 150/75 P5/P12 BFOU 0.6/1kV 3X 150/75 P5/P12 BFOU 0.6/1kV 4X 150/75 P5/P12 BLACK BLACK BLACK Yes - 7021528003178 7021528003024 7021528003093 1043652 - 20110765 20118466 BFOU 0.6/1kV 3X 185/95 P5/P12 BFOU 0.6/1kV 4X 185/95 P5/P12 BLACK BLACK - 7021528003925 7021528003918 - BFOU 0.6/1kV 2X 240/120 P5/P12 BFOU 0.6/1kV 3X 240/120 P5/P12 BLACK BLACK - 7021528003154 7021528003147 - 800315 800314 Electrical values power cables Number of elements Cross Electrical Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit section Cross type resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 core, section braid, 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, second, mm² mm² Ampere Ampere 2 3 4 150 150 150 75 75 75 KGTFR KGTFR KGTFR 0.126 0.126 0.126 0.161 0.161 0.161 0.072 0.073 0.073 0.088 0.088 0.088 331 272 272 21000 21000 21000 3 4 185 185 95 95 KGTFR KGTFR 0.1 0.1 0.128 0.128 0.073 0.073 0.088 0.088 311 311 25900 25900 2 3 240 240 120 120 KGTFR KGTFR 0.0762 0.0762 0.0972 0.0972 0.074 0.074 0.089 0.089 444 365 33600 33600 Subject to change without prior notice Page 67 of 212 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 68 of 212 Halogen-free, mud resistant, fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, large single core cables Fire resistant, flame retardant halogen-free power cable. Mud resistant. Single core cable. BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Black Marking text Manufacturing unit Outer sheath colour *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 69 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 1 35 ± 1.5 38 ± 1.5 42 ± 2 2.1 2.2 2.3 41 ± 2 44.5 ± 2 48.5 ± 2 5130 6240 7690 3974 4923 6205 400 500 630 25 25 25 26.00 29.0 32.80 2.6 2.8 2.8 1.4 1.4 1.4 0.4 0.4 0.4 31.7 36.2 40.7 Ordering information New Part number Old Part number 20132148 800212 800213 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK BFOU 0.6/1kV 1X 500/25 P5/P12 BLACK BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK - 7021528002119 7021528002126 7021528002133 - Electrical values power cables Number of elements Cross Electrical Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit section Cross type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 core, section braid, 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table B.4, second, mm² mm² Ampere Ampere 1 400 25 STCC 0.0475 0.0606 0.088 0.105 1 500 25 STCC 0.0369 0.0471 0.086 0.103 1 630 25 STCC 0.0286 0.0365 0.084 0.100 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac 56000 70000 88200 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 70 of 212 Halogen-free, mud resistant insulated conductor UX 1000V, P15 Flame retardant conductors UX 1000V Halogen-free, NEK TS 606 Type: P15 Maximum operating Conductor temperature Operating voltage Application Standards applied Insulated conductor for earthing and bonding services. Mud resistant in accordance with NEK TS 606:2009. IEC:60092-353 & NEK TS 606:2009 IEC:60228 class 2 IEC:60332-1 IEC:60332-3-22 IEC:60754-1,2 IEC:61034-1,2 : 90°C : 1000V - Design guidelines - Conductor - Flame retardance - Flame retardance - Halogen-free properties - Smoke density CONSTRUCTION CODE LETTER Conductor Insulation U Unsheathed X Tinned, stranded copper, IEC 60228 class 2 PETP-tape. Flame retardant halogen-free thermoset compound, HF90 (IEC 60092-360). Marking E.g; ”meter” ”year” DRAKA NORSK KABEL UX 1000V P15 1x 95 mm² IEC 332-3-22 Colour Yellow/green Subject to change without prior notice Page 71 of 212 RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15 Conductor area (mm²) Conductor diameter approx. (mm) Insulation thickness (mm) Diameter over insulation (mm) Weight of conductor approx. (kg/km) Copper content approx. (kg/km) 6 3,15 1,0 5,5±0,8 80 54 10 4,05 1,0 6,5±0,8 120 87 16 5,15 1,0 7,5±0,8 180 143 25 6,4 1,2 9,5±0,8 280 224 35 7,65 1,2 10,5±1,0 370 310 50 9,00 1,4 12,5±1,0 520 430 70 10,85 1,4 14,5±1,0 730 620 95 12,60 1,6 16,5±1,0 970 840 120 14,20 1,6 18,0±1,0 1220 1080 150 15,90 1,8 20,0±1,5 1520 1342 185 17,70 2,0 22,0±1,5 1890 1670 240 20,15 2,2 25,0±1,5 2450 2183 300 22,60 2,4 28,0±1,5 3090 2762 630 32,80 2,8 38,5±2,0 6350 5800 Electrical characteristics: Conductor area (mm²) Max. conductor Max. conductor Current rating resistance at resistance at IEC 60092-352 20°C, 90°C, Table B.4, Ohm/km Ohm/km Ampere Short circuit rating at 1 second, Ampere 6 3.11 3.97 52 840 10 1.84 2.35 72 1400 16 1.16 1.48 96 2240 25 0.734 0.936 127 3500 35 0.529 0.675 157 4900 50 0.391 0.499 196 7000 70 0.27 0.344 242 9800 95 0.195 0.249 293 13300 120 0.154 0.196 339 16800 150 0.126 0.161 389 21000 185 0.100 0.128 444 25900 240 0.0762 0.0972 522 33600 300 0.0607 0.0774 601 42000 630 0.0286 0.0359 890 dc / 780 ac 88200 Installation recommendations: In accordance with IEC 60092-352 Minimum bending radius During installation Maximum pulling tension Fixed installed 25N x total cross section of conductors 8 x cable diameter Minium installation temperature - 20 °C 6 x cable diameter Subject to change without prior notice Page 72 of 212 Ordering information: New Part number Old Part number Conductor area (mm²) Stock item El-number (Norway only) 800810 800811 800812 800815 6 10 16 25 35 50 70 95 120 150 185 240 300 630 Yes Yes Yes Yes Yes Yes Yes Yes - 1045541 1045542 1045543 1045553 1045563 1045573 1045583 1045593 1045603 1045604 - 20109530 20109531 20109532 20109533 20109534 20109535 20109536 20109537 20121097 20109538 Subject to change without prior notice Page 73 of 212 Halogen-free, fire resistant, unarmoured, mud resistant power cable, BU 0,6/1(1,2)kV, P17 Fire resistant, flame retardant halogen-free power cable. Mud resistant BU 0,6/1(1,2)kV MGT/EPR/EVA NEK TS 606 CodeP17 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as battery cables. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Armour/screen Outer sheath B U Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BU 0,6/1kV P17 1 x 70 mm2 IEC 60331-21 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Black Page 74 of 212 Core identification power cables Single core – Black Two cores - Blue – Brown Three cores - Brown - Black – Grey Four cores - Blue - Brown - Black – Grey Five cores - Blue - Brown - Black - Grey – Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue – Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Number of elements Cross section Conductor core, mm² Diameter, mm Insulation Thickness, mm Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 1 1 1 1 1 1 1 1 1 10 16 25 35 50 70 95 120 150 185 240 4.05 5.15 6.45 7.65 9.0 10.85 12.60 14.20 15.90 17.70 20.15 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 1 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.7 8.5 ± 0.5 10 ± 0.8 11.5 ± 0.8 13 ± 0.8 15 ± 0.8 17 ± 0.8 19.5 ± 0.8 21 ± 1 23.5 ± 1 25.5 ± 1 29 ± 1 165 235 350 460 620 850 1120 1380 1730 2100 2700 91 146 231 314 434 632 847 1082 1360 1664 2165 2 3 7 19 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.5 10 ± 0.8 10.5 ± 0.8 13 ± 0.8 21 ± 1 150 175 310 740 28 42 98 266 3G 7G 1.5 1.5 1.6 1.6 1.0 1.0 1.1 1.2 10.5 ± 0.8 13 ± 0.8 175 310 42 98 2 3 7 12 19 2.5 2.5 2.5 2.5 2.5 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.0 1.1 1.2 1.3 1.4 1.6 11 ± 0.8 11.5 ± 0.8 14.5 ± 0.8 19.5 ± 0.8 23 ± 1 185 220 400 640 970 46 69 161 276 436 3G 4G 5G 2.5 2.5 2.5 2.0 2.0 2.0 1.0 1.0 1.0 1.2 1.2 1.3 11.5 ± 0.8 13 ± 0.8 14.5 ± 0.8 220 265 340 69 92 115 3 4 2.55 1.0 1.2 13 ± 0.8 295 110 3G 4G 4 4 2.55 2.55 1.0 1.0 1.2 1.3 13 ± 0.8 14.5 ± 0.8 295 370 110 147 2 3 6 6 3.15 3.15 1.0 1.0 1.2 1.2 13.5 ± 0.8 14.5 ± 0.8 310 380 110 164 4G 5G 6 6 3.15 3.15 1.0 1.0 1.3 1.4 16 ± 0.8 18 ± 0.8 480 600 219 273 2 3 10 10 4.05 4.05 1.0 1.0 1.3 1.3 15.5 ± 0.8 16.5 ± 0.8 440 550 182 272 4G 10 4.05 1.0 1.4 18.5 ± 0.8 690 363 3 16 5.15 1.0 1.4 19 ± 0.8 790 438 4G 16 5.15 1.0 1.5 21.5 ± 1 1000 584 3 25 6.45 1.2 1.5 23 ± 1 1190 694 3G 25 6.45 1.2 1.5 23 ± 1 1190 694 Subject to change without prior notice Page 75 of 212 Number of elements 3 Cross section Conductor core, mm² Diameter, mm 35 7.65 Insulation Thickness, mm 1.2 Thickness Outer Sheath, mm 1.7 Diameter outer sheath, mm 26 ± 1 Weight of Cable Approx. (Kg/Km) 1550 Copper content Approx. (kg/km) 942 4G 35 7.65 1.2 1.7 29 ± 1 2000 1256 3 50 9.0 1.4 1.9 30 ± 1.5 2120 1306 3 150 15.9 1.8 2.3 48 ± 2 5910 4091 4G 150 15.9 1.8 2.5 53.5 ± 2.5 7750 5455 Ordering information New Part number Old Part number 20130809 Description Sheath Colour Stock item EAN No. DNK EL No. 801209 BU 0.6/1kV 1X 10mm² P17 BU 0.6/1kV 1X 16mm² P17 BU 0.6/1kV 1X 25mm² P17 BU 0.6/1kV 1X 35mm² P17 BU 0.6/1kV 1X 50mm² P17 BU 0.6/1kV 1X 70mm² P17 BU 0.6/1kV 1X 95mm² P17 BU 0.6/1kV 1X 120mm² P17 BU 0.6/1kV 1X 150mm² P17 BU 0.6/1kV 1X 185mm² P17 BU 0.6/1kV 1X 240mm² P17 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528012149 7021528012002 7021528012019 7021528012026 7021528012033 7021528012040 7021528012057 7021528012064 7021528012071 7021528012088 7021528012095 1061201 1061203 1061205 1061207 - 801218 801225 801228 BU 0.6/1kV 2X 1.5mm² P17 BU 0.6/1kV 3X 1.5mm² P17 BU 0.6/1kV 7X 1.5mm² P17 BU 0.6/1kV 19X 1.5mm² P17 BLACK BLACK BLACK BLACK - 7021528012156 7021528012187 7021528012255 7021528012286 - 801224 BU 0.6/1kV 3G 1.5mm² P17 BU 0.6/1kV 7G 1.5mm² P17 BLACK BLACK - 7021528012163 7021528012248 - 801233 BU 0.6/1kV 2X 2.5mm² P17 BLACK - 7021528012330 - 801236 801244 801245 801246 BU 0.6/1kV 3X 2.5mm² P17 BU 0.6/1kV 7X 2.5mm² P17 BU 0.6/1kV 12X 2.5mm² P17 BU 0.6/1kV 19X 2.5mm² P17 BLACK BLACK BLACK BLACK - 7021528012361 7021528012446 7021528012453 7021528012460 - 20096771 20117121 20131218 BU 0.6/1kV 3G 2.5mm² P17 BU 0.6/1kV 4G 2.5mm² P17 BU 0.6/1kV 5G 2.5mm² P17 BLACK BLACK BLACK Yes - 7021528012347 7021528012378 7021528012408 - 20109456 BU 0,6/1KV 3X 4 MM2 P17 BLACK - 7021528012538 - BU 0.6/1kV 3G 4mm² P17 BU 0.6/1kV 4G 4mm² P17 BLACK BLACK - 7021528012545 7021528012569 - 801261 BU 0,6/1KV 2X 6 MM2 P17 BU 0.6/1kV 3X 6mm² P17 BLACK BLACK - 7021528012590 7021528012613 - 801263 BU 0.6/1kV 4G 6mm² P17 BU 0.6/1kV 5G 6mm² P17 BLACK BLACK - 7021528012620 7021528012637 - 801266 801267 BU 0.6/1kV 2X 10mm² P17 BU 0.6/1kV 3X 10mm² P17 BLACK BLACK - 7021528012668 7021528012675 - BU 0.6/1kV 4G 10mm² P17 BLACK - 7021528012699 - 20121091 BU 0.6/1kV 3X 16mm² P17 BLACK - 7021528012736 - 20113144 BU 0.6/1kV 4G 16mm² P17 BLACK - 7021528012750 - 801279 BU 0.6/1kV 3X 25mm² P17 BLACK - 7021528012798 - 801280 BU 0.6/1kV 3G 25mm² P17 BLACK - 7021528012804 - 801286 BU 0,6/1KV 3X 35 mm² P17 BLACK - 7021528012866 - 801200 801201 20110766 20121092 20110767 801205 20121093 20109454 20132893 20109455 20112689 801254 2019457 20109458 20109459 20109460 Subject to change without prior notice Page 76 of 212 New Part number Old Part number 20109461 Description Sheath Colour Stock item EAN No. DNK EL No. BU 0.6/1kV 4G 35mm² P17 BLACK - 7021528012897 - 801292 BU 0,6/1KV 3X 50 mm² P17 BLACK - 7021528012927 - 801298 BU 0,6/1KV 3X 150 mm² P17 BLACK - 702152801298 - BU 0.6/1kV 4G 150mm² P17 BLACK - 7021528013078 - 20109462 Electrical values power cables Number of elements Cross section core, mm² Max. conductor Max. conductor Reactance at Reactance at resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km Ohm/km Ohm/km Current rating IEC Short circuit 60092-352 Table rating 1 second, B.4, Ampere Ampere 1 1 1 1 1 1 1 1 1 1 1 10 16 25 35 50 70 95 120 150 185 240 1.84 1.16 0.734 0.529 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.128 0.107 0.1 0.096 0.093 0.091 0.087 0.086 0.084 0.084 0.083 0.082 0.128 0.12 0.115 0.111 0.11 0.105 0.103 0.1 0.1 0.099 0.098 72 96 127 157 196 242 293 339 389 444 522 1400 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 2 3 7 19 1.5 1.5 1.5 1.5 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 0.11 0.11 0.11 0.11 0.138 0.138 0.138 0.138 20 16 12 8.5 210 210 210 210 3G 7G 1.5 1.5 12.2 12.2 15.6 15.6 0.11 0.11 0.138 0.138 20 12.5 210 210 2 3 7 12 19 2.5 2.5 2.5 2.5 2.5 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 15.6 15.6 0.103 0.103 0.103 0.103 0.103 0.129 0.129 0.129 0.129 0.129 26 21 15.5 13 11 350 350 350 350 350 3G 4G 5G 2.5 2.5 2.5 7.56 7.56 7.56 9.64 9.64 9.64 0.103 0.103 0.103 0.129 0.129 0.129 26 21 21 350 350 350 3 4 4.7 5.99 0.096 0.120 28 560 3G 4G 4 4 4.7 4.7 9.64 9.64 0.096 0.096 0.120 0.120 34 28 560 560 2 3 6 6 3.11 3.11 3.97 3.97 0.09 0.09 0.112 0.112 44 36 840 840 4G 5G 6 6 3.11 3.11 3.97 3.97 0.09 0.09 0.112 0.112 36 36 840 840 2 3 10 10 1.84 1.84 3.97 2.35 0.084 0.084 0.105 0.105 61 50 1400 1400 4G 10 1.84 2.35 0.084 0.105 50 1400 3 16 1.16 1.48 0.08 0.099 67 2240 4G 16 1.16 1.48 0.08 0.099 67 2240 3 25 0.734 0.936 0.079 0.098 89 3500 3G 25 0.734 0.936 0.079 0.098 108 3500 3 35 0.529 0.675 0.076 0.094 110 4900 Subject to change without prior notice Page 77 of 212 Number of elements 4G Cross Max. conductor Max. conductor Reactance at Reactance at Current rating IEC Short circuit section resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km 60092-352 Table rating 1 second, core, mm² Ohm/km Ohm/km B.4, Ampere Ampere 35 0.529 0.675 0.076 0.094 110 4900 3 50 0.391 0.499 0.076 0.093 137 7000 3 150 0.126 0.161 0.072 0.088 272 21000 4G 150 0.126 0.161 0.072 0.088 272 21000 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 78 of 212 Halogen-free, unarmoured, mud resistant power cable, RU 0,6/1(1,2)kV, P18 Flame retardant halogen-free power cable. Mud resistant RU 0,6/1(1,2)kV EPR/EVA NEK TS 606 CodeP18 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. These cables are double-insulated and Single core cables are used as battery cables. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Armour/screen Outer sheath R U Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers No inner covering. (Additional tapes may be applied) No armour. Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RU 0,6/1KV P18 3 x 2,5 mm2 IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel, Black Page 79 of 212 Core identification power cables Single core – Black Two cores - Blue – Brown Three cores - Brown - Black – Grey Four cores - Blue - Brown - Black – Grey Five cores - Blue - Brown - Black - Grey – Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue – Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445 Ed 5.0 2010-08 Range and dimensions Number of elements Cross section Conductor core, mm² Diameter, mm Insulation Thickness, mm Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 1 1 1 1 1 1 1 25 50 70 95 120 150 185 240 300 6.45 9.0 10.9 12.60 14.20 15.90 17.70 20.15 22.60 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.1 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.8 11.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 19 ± 0.8 20.5 ± 1 23 ± 1 25.5 ± 1 28.5 ± 1 31.5 ± 1.5 340 610 820 1110 1370 1710 2090 2680 3370 231 434 632 847 1082 1357 1664 2165 2757 2 3 4 5 7 12 19 24 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.2 1.2 1.4 1.5 1.6 9.5 ± 0.5 10 ± 0.8 11 ± 0.8 12 ± 0.8 12.5 ± 0.8 16.5 ± 0.8 19.5 ± 0.8 25 ± 1 135 160 190 240 280 460 680 890 28 42 56 70 98 168 266 335 3G 4G 5G 7G 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 10 ± 0.8 11 ± 0.8 12 ± 0.8 12.5 ± 0.8 160 190 240 280 42 56 70 98 2 3 4 5 7 2.5 2.5 2.5 2.5 2.5 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.3 10.5 ± 0.8 11 ± 0.8 12 ± 0.8 13.5 ± 0.8 14 ± 0.8 170 205 250 320 390 46 69 92 115 161 3G 4G 5G 2.5 2.5 2.5 2.0 2.0 2.0 1.0 1.0 1.0 1.1 1.2 1.2 11 ± 0.8 12 ± 0.8 13.5 ± 0.8 205 255 320 69 92 115 2 3 4 4 4 4 2.55 2.55 2.55 1.0 1.0 1.0 1.1 1.2 1.2 11.5 ± 0.8 12 ± 0.8 13.5 ± 0.8 220 275 340 74 110 147 3G 4G 5G 4 4 4 2.55 2.55 2.55 1.0 1.0 1.0 1.2 1.2 1.3 12 ± 0.8 13.5 ± 0.8 15 ± 0.8 275 340 410 110 147 184 2 6 3.15 1.0 1.2 12.5 ± 0.8 290 110 3 4 6 6 3.15 3.15 1.0 1.0 1.2 1.3 13.5 ± 0.8 15 ± 0.8 360 450 164 219 3G 4G 5G 6 6 6 3.15 3.15 3.15 1.0 1.0 1.0 1.2 1.3 1.3 13.5 ± 0.8 15 ± 0.8 16.5 ± 0.8 360 450 550 164 219 273 2 3 10 10 4.05 4.05 1.0 1.0 1.2 1.3 14.5 ± 0.8 15.5 ± 0.8 410 530 182 272 Subject to change without prior notice Page 80 of 212 Number of elements 4G 5G Cross section core, mm² 10 10 Conductor Diameter, mm 4.05 4.05 Insulation Thickness, mm 1.0 1.0 Thickness Outer Sheath, mm 1.3 1.4 Diameter outer sheath, mm 17.5 ± 0.8 19 ± 0.8 Weight of Cable Approx. (Kg/Km) 660 820 Copper content Approx. (kg/km) 363 453 2 3 4 16 16 16 5.15 5.15 5.15 1.0 1.0 1.0 1.3 1.4 1.4 17 ± 0.8 18.5 ± 0.8 20 ± 1 600 780 950 292 438 585 3G 4G 5G 16 16 16 5.15 5.15 5.15 1.0 1.0 1.0 1.4 1.4 1.5 18.5 ± 0.8 20 ± 1 22.5 ± 1 780 980 1200 438 584 730 2 3 4 25 25 25 6.45 6.45 6.45 1.2 1.2 1.2 1.4 1.5 1.6 20.5 ± 1 22.5 ± 1 24.5 ± 1 900 1170 1420 463 694 924 4G 25 6.45 1.2 1.6 25 ± 1 1500 925 2 3 35 35 7.65 7.65 1.2 1.2 1.5 1.6 23 ± 1 25 ± 1 1150 1520 629 943 4G 5G 35 35 7.65 7.65 1.2 1.2 1.7 1.8 28 ± 1 31 ± 1.5 1950 2370 1257 1571 3 50 9.0 1.4 1.7 29.5 ± 1 2090 1306 5G 50 9.0 1.4 2 36.5 ± 1.5 3310 2177 3 70 10.85 1.4 1.9 34 ± 1.5 2900 1900 5G 70 10.85 1.4 2.1 42 ± 2 4550 3167 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 831701 831703 831704 831705 831706 831707 831708 831709 831710 RU 0.6/1kV 1X 25mm² P18 RU 0.6/1kV 1X 50mm² P18 RU 0,6/1KV 1X 70 MM2 P18 RU 0.6/1kV 1X 95mm² P18 RU 0.6/1kV 1X 120mm² P18 RU 0.6/1kV 1X 150mm² P18 RU 0.6/1kV 1X 185mm² P18 RU 0.6/1kV 1X 240mm² P18 RU 0.6/1kV 1X 300mm² P18 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528317015 7021528317039 7021528317046 7021528317053 7021528317060 7021528317077 7021528317084 7021528317091 7021528317107 1061403 1061407 - 831715 831724 831725 831726 831728 831729 RU 0.6/1kV 2X 1.5mm² P18 RU 0.6/1kV 3X 1.5mm² P18 RU 0.6/1kV 4X 1.5mm² P18 RU 0.6/1kV 5X 1.5mm² P18 RU 0.6/1kV 7X 1.5mm² P18 RU 0.6/1kV 12X 1.5mm² P18 RU 0.6/1kV 19X 1.5mm² P18 RU 0,6/1KV 24X 1,5 MM2 P18 BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528317152 7021528317183 7021528317213 7021528317244 7021528317251 7021528317268 7021528317282 7021528317299 - 831719 831720 831723 RU 0.6/1kV 3G 1.5mm² P18 RU 0.6/1kV 4G 1.5mm² P18 RU 0.6/1kV 5G 1.5mm² P18 RU 0.6/1kV 7G 1.5mm² P18 BLACK BLACK BLACK BLACK - 7021528317169 7021528317190 7021528317206 7021528317237 - 831739 RU 0.6/1kV 2X 2.5mm² P18 RU 0.6/1kV 3X 2.5mm² P18 RU 0,6/1KV 4X 2,5 MM2 P18 BLACK BLACK BLACK - 7021528317336 7021528317367 7021528317398 - 831741 831743 RU 0.6/1kV 5X 2.5mm² P18 RU 0.6/1kV 7X 2.5mm² P18 BLACK BLACK - 7021528317411 7021528317435 - 831740 RU 0.6/1kV 3G 2.5mm² P18 RU 0.6/1kV 4G 2.5mm² P18 RU 0.6/1kV 5G 2.5mm² P18 BLACK BLACK BLACK - 7021528317343 7021528317374 7021528317404 1061434 1061437 - 20115552 20130984 20109463 831733 20115556 20109464 20128690 Subject to change without prior notice Page 81 of 212 New Part number Old Part number 831751 831753 831755 RU 0.6/1kV 2X 4mm² P18 RU 0.6/1kV 3X 4mm² P18 RU 0,6/1KV 4X 4 MM2 P18 BLACK BLACK BLACK - 7021528317510 7021528317534 7021528317558 - 831754 831756 RU 0.6/1kV 3G 4mm² P18 RU 0.6/1kV 4G 4mm² P18 RU 0,6/1KV 5G 4mm² P18 BLACK BLACK BLACK - 7021528317527 7021528317541 7021528317565 - 831759 831761 831762 RU 0,6/1KV 2X 6 MM2 P18 RU 0.6/1kV 3X 6mm² P18 RU 0.6/1kV 4X 6mm² P18 BLACK BLACK BLACK - 7021528317596 7021528317619 7021528317626 - 831764 831763 RU 0.6/1kV 3G 6mm² P18 RU 0.6/1kV 4G 6mm² P18 RU 0.6/1kV 5G 6mm² P18 BLACK BLACK BLACK - 7021528317602 7021528317640 7021528317633 1061461 - 831766 831767 RU 0,6/1KV 2X 10 MM2 P18 RU 0.6/1kV 3X 10mm² P18 BLACK BLACK - 7021528317664 7021528317671 - 831769 831770 RU 0.6/1kV 4G 10mm² P18 RU 0.6/1kV 5G 10mm² P18 BLACK BLACK - 7021528317695 7021528317701 - 831772 831773 831774 RU 0.6/1kV 2X 16mm² P18 RU 0.6/1kV 3X 16mm² P18 RU 0,6/1KV 4X 16 MM2 P18 BLACK BLACK BLACK - 7021528317725 7021528317732 7021528317749 - 831775 831777 RU 0.6/1kV 3G 16mm² P18 RU 0.6/1kV 4G 16mm² P18 RU 0.6/1kV 5G 16mm² P18 BLACK BLACK BLACK - 7021528317756 7021528317763 7021528317770 - 831779 831780 831781 RU 0.6/1kV 2X 25mm² P18 RU 0.6/1kV 3X 25mm² P18 RU 0,6/1KV 4X 25 MM2 P18 BLACK BLACK BLACK - 7021528317794 7021528317800 7021528317817 - 831782 RU 0.6/1kV 4G 25mm² P18 BLACK - 7021528317824 - 831785 831786 RU 0,6/1KV 2X 35 MM2 P18 RU 0.6/1kV 3X 35mm² P18 BLACK BLACK - 7021528317855 7021528317862 - 831788 831789 RU 0.6/1kV 4G 35mm² P18 RU 0.6/1kV 5G 35mm² P18 BLACK BLACK - 7021528317886 7021528317893 - 831792 RU 0.6/1kV 3X 50mm² P18 BLACK - 7021528317923 - 831796 RU 0.6/1kV 5G 50mm² P18 BLACK - 7021528317961 - 831798 RU 0.6/1kV 3X 70mm² P18 BLACK - 7021528317985 - 831799 RU 0.6/1kV 5G 70mm² P18 BLACK - 7021528317992 - 20109465 20109466 20109467 Description Sheath Colour Stock item EAN No. DNK EL No. Electrical values power cables Number of elements Cross section core, mm² Max. conductor Max. conductor Reactance at Reactance at resistance at 20°C, resistance at 90°C, 50Hz, Ohm/km 60Hz, Ohm/km Ohm/km Ohm/km Current rating IEC Short circuit 60092-352 Table rating 1 second, B.4, Ampere Ampere 1 1 1 1 1 1 1 1 1 25 50 70 95 120 150 185 240 300 0.734 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 0.499 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.094 0.09 0.085 0.085 0.083 0.082 0.082 0.081 0.08 0.113 0.108 0.102 0.102 0.1 0.099 0.098 0.098 0.096 127 196 242 293 339 389 444 522 601 3500 7000 9800 13300 16800 21000 25900 33600 42000 2 3 4 5 7 1.5 1.5 1.5 1.5 1.5 12.2 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 15.6 0.11 0.11 0.11 0.11 0.11 0.132 0.132 0.132 0.132 0.132 20 16 16 13.5 12 210 210 210 210 210 Subject to change without prior notice Page 82 of 212 Number of elements 12 19 24 Cross Max. conductor section resistance at 20°C, core, mm² Ohm/km 1.5 12.2 1.5 12.2 1.5 12.2 Max. conductor resistance at 90°C, Ohm/km 15.6 15.6 15.6 0.132 0.132 0.132 Current rating IEC 60092-352 Table B.4, Ampere 10 8.5 8 Short circuit rating 1 second, Ampere 210 210 210 0.11 0.11 0.11 3G 4G 5G 7G 1.5 1.5 1.5 1.5 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 0.11 0.11 0.11 0.11 0.132 0.132 0.132 0.132 20 16 16 12.5 210 210 210 210 2 3 4 5 7 2.5 2.5 2.5 2.5 2.5 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 9.64 0.103 0.103 0.103 0.103 0.103 0.123 0.123 0.123 0.123 0.123 26 21 21 17.5 15.5 350 350 350 350 350 3G 4G 5G 2.5 2.5 2.5 7.56 7.56 7.56 9.64 9.64 9.64 0.103 0.103 0.103 0.123 0.123 0.123 26 21 21 350 350 350 2 3 4 4 4 4 4.7 4.7 4.7 5.99 5.99 5.99 0.096 0.096 0.096 0.115 0.115 0.115 34 28 28 560 560 560 3G 4G 5G 4 4 4 4.7 4.7 4.7 5.99 5.99 5.99 0.096 0.096 0.096 0.115 0.115 0.115 34 28 28 560 560 560 2 3 4 6 6 6 3.11 3.11 3.11 3.97 3.97 3.97 0.09 0.09 0.09 0.108 0.108 0.108 44 36 36 840 840 840 3G 4G 5G 6 6 6 3.11 3.11 3.11 3.97 3.97 3.97 0.09 0.09 0.09 0.108 0.108 0.108 44 36 36 840 840 840 2 3 10 10 1.84 1.84 2.35 2.35 0.084 0.084 0.101 0.101 61 50 1400 1400 4G 5G 10 10 1.84 1.84 2.35 2.35 0.084 0.084 0.101 0.101 50 50 1400 1400 2 3 4 16 16 16 1.16 1.16 1.16 1.48 1.48 1.48 0.08 0.08 0.08 0.096 0.096 0.096 80 67 67 2240 2240 2240 3G 4G 5G 16 16 16 1.16 1.16 1.16 1.48 1.48 1.48 0.08 0.08 0.08 0.096 0.096 0.096 80 67 67 2240 2240 2240 2 3 4 25 25 25 0.734 0.734 0.734 0.936 0.936 0.936 0.079 0.079 0.079 0.095 0.095 0.095 108 89 89 3500 3500 3500 4G 25 0.734 0.936 0.079 0.095 89 3500 2 3 35 35 0.529 0.529 0.675 0.675 0.076 0.076 0.092 0.092 133 110 4900 4900 4G 5G 35 35 0.529 0.529 0.675 0.675 0.076 0.076 0.092 0.092 110 110 4900 4900 3 50 0.391 0.499 0.076 0.092 137 7000 5G 50 0.391 0.499 0.076 0.092 137 7000 3 70 0.27 0.344 0.074 0.088 169 9800 5G 70 0.27 0.344 0.074 0.088 169 9800 Subject to change without prior notice Reactance at Reactance at 50Hz, Ohm/km 60Hz, Ohm/km Page 83 of 212 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 84 of 212 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with flexible conductors class 5 and separate earth cores Flame retardant cables RFOU-VFD 0,6/1 (1,8/3)kV Power cable for variable frequency drives Class 5 conductors Halogen free and Mud resistant Maximum operating conductor temperature : 90°C Operating voltage : 0,6/1(1,2)kV Application Standards applied Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606. IEC 60092-353 IEC 60228 class 5 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke CONSTRUCTION CODE LETTER Conductor Insulation Tinned, annealed, flexible copper, IEC 60228 class 5. R EP-rubber, IEC 60092-360 (EPR) Bedding F 3 insulated phase-conductors are laid up with 3 insulated earth conductors. Flame retardant halogen-free thermoset compound Armour O Lay up Outer sheath U Cu/PETP-tape Tinned copper wire braid. PETP-tape Shield coverage is 100% Flame retardant halogen-free thermoset compound, SHF2 (IEC 60092-360). Marking E.g; ”meter” ”DRAKA 01 RFOU – VFD 0,6/1(1,8/3)kV 3 95 + 3 x 16 mm² IEC 60332-3-22 Colour Black or Yellow Subject to change without prior notice Page 85 of 212 Core identification: The three main power cores: All three Earth cores: Brown – Black – Grey Yellow/green RANGE AND DIMENSIONS RFOU-VFD 0,6/1(1,8/3) kV No. of cores and cond. area mm² Thickness of bedding approx. mm Cond. diam. appr. Insulation thickness mmØ mm Diameter over bedding mmØ Armour/ screen wire diameter mmØ Thickness of outer sheath, nominal mm Diameter overall Weight of cable mmØ kg/km Copper content Approx. (kg/km) 3x 10 + 3x 4 4.3 2.7 2.8 1.0 1.5 24.5 ± 1,0 0.30 1.6 29,0 ± 1,0 1470 525 3x 25 + 3x 6 7,2 3,3 2,2 1.0 1,6 28,5±1,0 0,30 1,8 33,5±1,5 2180 1045 3x 35 + 3x 6 8,45 3,3 2,2 1,0 1.6 31.5 ± 1.5 0.30 1.9 36.5 ± 1.5 2540 1320 3x 50 + 3x 10 10,65 4,3 2,4 1,0 1,6 36,0±1,5 0,30 2,0 41,5±2,0 3500 1860 3x 95 + 3x 16 14,3 5.9 2,4 1,0 1,6 45,0±2,0 0,40 2,3 51,0±2,5 5690 3400 3x 95 + 3x 25 14,3 7,2 2,4 1,2 1,6 45.5±2,0 0,4 2,3 52±2,0 6000 3650 3x 120 + 3x 25 16,6 7,2 2,4 1,2 1,8 50,0±2,5 0,40 2,5 57,0±2,5 7130 4380 3x 150 + 3x 16 18,1 5,9 2,4 1,0 1,8 53,5±2,5 0,40 2,6 60,5±3,0 8200 5105 3x 150 + 3x 25 18,1 2,4 1,0 1,8 53,5 ± 2,5 0,40 2,6 60,5 ± 3,0 8390 5345 3x 150 + 3x 35 18,1 2,4 1,2 1,8 53,5 ± 2,5 0,40 2,6 60,5 ± 3,0 8560 5590 3x 185 + 3x 16 19,9 5,9 2,4 1,0 1,8 57,5±2,5 0,40 2,7 65,0±3,0 9550 6060 Tba = to be agreed in case of an order Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. RFOU-VFD 1kV(3kV) 3x 10 mm² + 3x 4 mm² 886833 RFOU-VFD 1kV(3kV) 3x 10 mm² + 3x 4 mm² YELLOW BLACK - -7021528868333 - 886829 RFOU-VFD 1kV(3kV) 3x 25 mm² + 3x 6 mm² RFOU-VFD 1kV(3kV) 3x 25 mm² + 3x 6 mm² YELLOW BLACK - 7021528868296 - - RFOU-VFD 1kV(3kV) 3x 35 mm² + 3x 6 mm² RFOU-VFD 1kV(3kV) 3x 35 mm² + 3x 6 mm² BLACK YELLOW - - - 20109486 886828 RFOU-VFD 1kV(3kV) 3x 50 mm² + 3x 10 mm² RFOU-VFD 1kV(3kV) 3x 50 mm² + 3x 10 mm² YELLOW BLACK - 7021528868589 7021528868319 - 20109487 886360 RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 16 mm² RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 16 mm² YELLOW BLACK - 7021528863604 7021528868326 - RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 25 mm² RFOU-VFD 1kV(3kV) 3x 95 mm² + 3x 25 mm² YELLOW BLACK - - - 886756 RFOU-VFD 1kV(3kV) 3x 120 mm² + 3x 25 mm² 887077 RFOU-VFD 1kV(3kV) 3x 120 mm² + 3x 25 mm² YELLOW BLACK - 7021528867565 7021528870770 - 886421 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 16 mm² RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 16 mm² YELLOW BLACK - 7021528864212 - - Subject to change without prior notice Page 86 of 212 New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 25 mm² 887078 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 25 mm² YELLOW BLACK - 7021528870787 - 886793 RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 35 mm² RFOU-VFD 1kV(3kV) 3x 150 mm² + 3x 35 mm² YELLOW BLACK - 7021528867930 - - 887207 RFOU-VFD 1kV(3kV) 3x 185 mm² + 3x 16 mm² RFOU-VFD 1kV(3kV) 3x 185 mm² + 3x 16 mm² YELLOW BLACK - 7021528872071 - - Electrical values power cables No. of cores and cond. area mm² Resistance at 20°C Resistance at 90°C Reactance at 50Hz Current rating at 45°C ohm/km ohm/km Ohm/km Ampere Short curcuit rating 1 sec. Ampere 3x 10 + 3x 4 1,95 5,09 2,49 6,49 0,083 50 1400 3x 25 + 3x 6 0,795 3,39 1,014 4,323 0,089 89 3500 3x 35 + 3x 6 0,565 3,39 0,668 4,323 0,086 110 4900 3x 50 + 3x 10 0,393 1,95 0,501 2,486 0,081 137 7000 3x 95 + 3x 16 0,210 1,24 0,268 1,58 0,077 205 13300 3x 95 + 3x 25 0,210 0,795 0,268 1,014 0,077 205 13300 3x 120 + 3x 25 0,164 0,795 0,209 1,014 0,075 237 16800 3x 150 + 3x 16 0,132 1,24 0,1683 1,58 0,074 272 21000 3x 150 + 3x 25 0,132 0,795 0,1683 1,013 0,074 272 21000 3x 150 + 3x 35 0,132 0,565 0,1683 0,7204 0,074 272 21000 3x 185 + 3x 16 0,108 1,24 0,1683 1,58 0,073 311 25900 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 87 of 212 Cable for Variable Frequency Drives (VFD’s), RFOU-VFD 0,6/1(1,8/3)kV with stranded conductors class 2 and tinned copper wire braid as earth Flame retardant cables RFOU-VFD 0,6/1kV(1,8/3kV) EPR/EPR/TCWB/EVA Halogen-free, Mud resistant Maximum operating Conductor temperature Operating voltage Application Standards applied Special cable for Variable Frequency Drives / Azimuth motors up to 1kV. Suitable for voltage peaks up to 3600V. Armoured cable for fixed installations in ships and offshore units. Can be installed and operated both indoors and outdoors. Oil and MUD resistant to NEK606. IEC 60092-353 IEC 60228 class 2 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 : 90OC : 0,6/1kV (3 kV) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke CONSTRUCTION CODE LETTER Conductor Circular, tinned, stranded copper. IEC 60228 Class 2 (1) Insulation R EP-rubber (2) Bedding F Flame retardant and halogen-free thermoset compound. (3) Armour O Outer sheath U Marking Colour Cu/PETP-tape. (4) Tinned copper wire braid. (5) Shield coverage is 100% PETP-tape. (6) Flame retardant, halogen-free and mud resistant thermoset compound, SHF2.(7) E.g; “meter” “year” DRAKA 01 RFOU-VFD 0,6/1kV (1,8/3) kV 3x 95/50 mm² IEC 60332-3-22 Yellow or Black Core identification: Three cores: Brown – Black - Grey Subject to change without prior notice Page 88 of 212 RANGE AND DIMENSIONS: RFOU-VFD 0,6/1kV (1,8/3)kV No. of cores and cond. area (mm²) Cond. diam. appr. (mmØ) Insulation thickness Diameter bedding (mm) Thickness of inner covering, mm (mmØ) 3x 2.5/10 3x 4/10 3x 6/10 3x 10/10 3x 16/16 3x 25/16 3x 50/25 3x 70/35 3x 95/50 3x 120/60 3x 150/70 2.0 2.55 3,15 4,05 5,15 6,75 9,10 10.85 12,60 14.20 15.90 2.2 2.2 2.2 2.2 2,2 2.2 2.2 2.2 2,4 2.4 2.4 1.1 1.1 1.2 1.2 1.6 1.6 1.7 1.6 2,0 2.0 1.4 16.5 ± 0.8 17.5 ± 0.8 19 ± 0.8 21 ± 1 24 ± 1 28 ± 1 33 ± 1.5 36.5 ± 1.5 42 ± 2,0 45.5 ± 2 48 ± 2,0 3x 185/95 17.7 2.4 2.0 53 ± 2.5 3x 240/120 20.15 2.4 1.8 58.5 ± 2.5 Diameter of armour /shield wire (mmØ) Thickness outer sheath, mm Diameter outer sheath (mmØ) Weight of cable approx (kg/km) Copper content Approx. (kg/km) 0.30 0.30 0.30 0.30 0.30 0.30 0.40 0.50 0.60 0.60 2 layer 0.40 2 layer 0.50 2 layer 0.60 1.5 1.5 1.6 1.6 1.7 1.8 2 2.2 2,3 2.5 2,7 20.5 ± 1 21.5 ± 1 23.5 ± 1 25 ± 1 29 ± 1 33 ± 1.5 38.5 ± 1.5 43 ± 2 49 ± 2 53 ± 2.5 56.5 ± 2,5 690 780 940 1130 1560 2090 3110 4160 5420 6590 7800 202 243 314 422 638 935 1617 2385 3166 3975 5015 2.8 63 ± 3 9660 6288 3 68.5 ± 3 11970 8050 Ordering information New Part number Old Part number 886852 886854 886972 886973 20114764 886971 886970 20109484 Description Sheath Colour RFOU-VFD 1kV(3kV) 3x 2.5/10 mm² RFOU-VFD 1kV(3kV) 3x 4/10 mm² RFOU-VFD 1kV(3kV) 3x 6/10 mm² RFOU-VFD 1kV(3kV) 3x 10/10 mm² RFOU-VFD 1kV(3kV) 3x 16/16 mm² RFOU-VFD 1kV(3kV) 3x 16/16 mm² RFOU-VFD 1kV(3kV) 3x 25/16 mm² RFOU-VFD 1kV(3kV) 3x 50/25 mm² RFOU-VFD 1kV(3kV) 3x 70/35 mm² RFOU-VFD 1kV(3kV) 3x 95/50 mm² RFOU-VFD 1kV(3kV) 3x 120/60 mm² RFOU-VFD 1kV(3kV) 3x 150/70 mm² RFOU-VFD 1kV(3kV) 3x 185/95 mm² RFOU-VFD 1kV(3kV) 3x 240/120 mm² BLACK BLACK BLACK BLACK YELLOW BLACK YELLOW YELLOW BLACK BLACK YELLOW BLACK YELLOW BLACK Stock item - EAN No. DNK 7021528868524 7021528868548 7021528869729 7021528869736 7021528868890 7021528869712 7021528869705 - Electrical characteristics No. of cores and cond. area (mm²) Resistance at 20°C 3x 2.5/10 3x 4/10 3x 6/10 3x 10/10 3x 16/16 3x 25/16 3x 50/25 3x 70/35 3x 95/50 3x 120/60 3x 150/70 3x 185/95 3x 240/120 7.56 4.7 3.11 1.84 1,16 0.734 0.391 0.270 0,195 0.154 0.126 0.100 0.0762 (ohm/km) Resistance at 90°C Reactance at 50Hz (ohm/km) 9.64 5.99 3.97 2.35 1.48 0.936 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 Subject to change without prior notice (ohm/km) Current rating at 45°C (ampere) Short curcuit rating, 1 sec (ampere) 0.131 0.122 0.114 0.105 0.098 0.091 0.084 0.081 0.080 0.078 0.076 0.074 0.073 21 28 36 50 67 89 137 169 205 237 273 311 366 350 560 840 1400 2240 3500 7000 9800 13300 16800 21000 25900 33600 Page 89 of 212 EL No. - Correction factors for different ambient temperatures: Ambient temp. °C Rating factors 25 30 35 40 45 50 55 60 65 70 75 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 0,61 0,5 Installation recommendations: In accordance with IEC 60092-352 Minimum bending radius During installation 8 x cable diameter Maximum pulling tension Minium installation temperature Fixed installed 6 x cable diameter Subject to change without prior notice 50N x total Cross section of conductors - 20 °C Page 90 of 212 Fire resistant optical fibre cable, QFCI-I/O/RM-JM/-, F1 QFCI-I/O/RM-JM/Indoor and outdoor. Fire resistant Flame retardant halogen-free Loose tube NEK 606 Code F1 Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type. The sheath colour is BLACK. Fibres in mica wrapped loose tube Steel strength element Wrapping Inner sheath Filler Steel wire braiding Outer sheath Weight and dimensions Number of fibres 4 8 12 24 48 Number of fibres in each tube 2 4 4 4 8 Number of tubes + fillers 2+4 2+4 3+3 6+0 6+0 Loose tube diameter (mm) 2.2 2.2 2.2 2.2 2.2 Outer diameter (mm) 13.5 13.5 13.5 13.5 13.5 Weight Heat release (kg/km) 260 260 260 260 260 (MJ/km) 1390 1381 1324 1138 1138 Other fibre counts are available on request. Cable properties Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation Crush (IEC 60794-1-2E3) Impact (IEC 60794-1-2E4) Torsion (IEC 60794-1-2E7) Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11) Temperature window Operation Installation Storage Subject to change without prior notice Chemical reistance 1500 N Mineral oils IRM 902 (IEC60811-2-1) 500 N Diesel - IRM 903 (IEC60811-2-1) 3000 N/10cm Fire and smoke classifications 30J IEC 60331-25 (750C, 90 minutes) 1 turn/1m Upgraded IEC 60331-25 (1000C, 3 hours) BP GS 112-2 Clause7.1 250 mm IEC 61034 <0.1dB/ 5 turn IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C) IEC 60754-1 -40C to +70C IEC 60754-2 -10C to +70C -40C to +70C - 7 days/23°C - 4 hours/70°C - 7 days/23°C - 4 hours/70°C <1.0 dB excess loss <1.5 dB excess loss Page 91 of 212 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet 20110842 8 G8-9/125 QFCI-I/O/RM-JM/- OS2 Single mode - C03e 20109401 12 G12-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e 20109404 24 G24-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e 20109399 48 G48-9/125 QFCI-I/O/RM-JM/- OS2 Single mode Yes C03e 20109398 4 G4-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C23 20109402 12 G12-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C23 C23 20110759 24 G24-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - 694169 48 G48-50/125 QFCI-I/O/RM-JM/- OM2 50/125 multi mode - C23 20109417 4 G4-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C31 C31 699875 12 G12-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - 699872 24 G24-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C31 20110843 48 G48-50/125OM3 QFCI-I/O/RM-JM/- OM3 MaxCap-OM3 - C31 20110462 4 G4-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C02 C02 20110463 8 G8-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes 20109403 12 G12-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes C02 C02 C02 20109405 24 G24-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode Yes 20109406 48 G48-62.5/125 QFCI-I/O/RM-JM/- OM1 62.5/125 multi mode - Colour codes Fibre Colour number 1 White 2 Red 3 Yellow 4 Green 5 Blue 6 Grey 7 Brown 8 Black Tube number 1 2 3 4 5 6 Colour Red Green White White White White We reserve the right to alter this specification without notice. Other fibre types and qualities are available on request. Subject to change without prior notice Page 92 of 212 Fire resistant optical fibre cable, QFCI-I/O/RM/C-JM/-, MUD PROTECTED (F5) QFCI-I/O/RM/C-JM/Indoor and outdoor. Fire resistant Flame retardant halogen-free Loose tube NEK 606 Code (F5) Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath(1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type. An additional outer sheath is added for improved oil- and MUD protection. The sheath colour is GREY. Fibres in mica wrapped loose tube Steel strength element Wrapping Inner sheath Filler Steel wire braiding Outer sheath (1) Outer sheath (MUD) Weight and dimensions Number of fibres 8 12 24 48 Number of fibres in each tube 4 4 4 8 Number of tubes + fillers 2+4 3+3 6+0 6+0 Loose tube diameter (mm) 2.2 2.2 2.2 2.2 Outer diameter (mm) 15.5 15.5 15.5 15.5 Weight (kg/km) 325 325 325 325 Heat release (Estimated) (MJ/km) 2000 2000 2000 2000 Other fibre counts are available on request. Cable properties Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation Crush (IEC 60794-1-2E3) Impact (IEC 60794-1-2E4) Torsion (IEC 60794-1-2E7) Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11) Temperature window Operation Installation Storage Subject to change without prior notice Chemical resistance 1500 N Mineral oils IRM 902 (IEC60811-2-1) 500 N Diesel - IRM 903 (IEC60811-2-1) 3000 N/10cm Fire and smoke classifications 30J IEC 60331-25 (750C, 90 minutes) 1 turn/1m Upgraded IEC 60331-25 (1000C, 3 hours) BP GS 112-2 Clause7.1 250 mm IEC 61034 <0.1dB/ 5 turn IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C) IEC 60754-1 -40C to +70C -10C to +70C -40C to +70C - 7 days/100°C - 7 days/100°C <1.0 dB excess loss <1.5 dB excess loss Page 93 of 212 Ordering information Part no 20109485 Number Cabe Type of fibres 8 G8-9/125 QFCI-I/O/RM/C-JM/- Fiber type Stock Item Fiber data sheet OS2 Single mode C03e 20109488 12 G12-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e 20109483 24 G24-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e 20116217 48 G48-9/125 QFCI-I/O/RM/C-JM/- OS2 Single mode C03e 20109490 8 G8-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 20112243 12 G12-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 20118902 24 G24-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 48 G48-50/125 QFCI-I/O/RM/C-JM/- OM2 50/125 multi mode C23 12 G12-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C31 24 G24-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C31 48 G48-50/125OM3 QFCI-I/O/RM/C-JM/- OM3 MaxCap-OM3 C31 4 G4-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 20110579 8 G8-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 20109481 12 G12-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 20109482 24 G24-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 20116216 48 G48-62.5/125 QFCI-I/O/RM/C-JM/- OM1 62.5/125 multi mode C02 20110577 Colour codes Fibre Colour number 1 White 2 Red 3 Yellow 4 Green 5 Blue 6 Grey 7 Brown 8 Black Tube number 1 2 3 4 5 6 Colour Red Green White White White White Standard colur on outer sheet is Grey We reserve the right to alter this specification without notice. Other fibre types and qualities are available on request. Subject to change without prior notice Page 94 of 212 Flame retardant optical fibre cable, AICI-I/O/RM-W, F6 AICI-I/O/RM-W Indoor and outdoor Flame retardant and halogen free Steel wire braiding Tight buffer NEK 606 Code F6 Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. The outer sheath is made from black UV-stabilized and weather resistant material which is SHF1 classified, and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 mm tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. The outer sheath is BLACK. Secondary coated fibre Water swellable material Glass yarn Inner sheath Steel wire braiding Outer sheath Weight and dimensions Number of fibres Secondary coating Outer diameter Weight [mm] 0.9 0.9 0.9 0.9 [mm] [kg/km] 4 8 12 24 8.2 9.4 10.3 12.0 90 125 145 185 Tensile strength* [Inst./oper.] [N] 700/250 800/350 1200/500 1700/750 Cable properties *Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation Crush (IEC 60794-1-2E3) Impact (IEC 60794-1-2E4) Torsion (IEC 60794-1-2E7) Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11) Flexibility (IEC 60794-1-2E8) Temperature window See above See above Operation Installation Storage -40C to +70C -10C to +70C -40C to +70C 2000 N/10cm Water tightness* (IEC 60794-1-2F5B) 1 impacts, 25J Fire and smoke classifications 1 turn/1m IEC 60332-1 IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C) 15x outer diameter IEC 61034 <0.5 dB/ 5 turn IEC 60754-1 1000 cycles IEC 60754-2 Chemical reistance Mineral oils IRM 902 (IEC60811-2-1) < 3 m/24 hours - 7 days/23°C - 4 hours/70°C Diesel - IRM 903 (IEC60811-2-1) - 7 days/23°C - 4 hours/70°C *) – Steel wire braiding is not watertight. Subject to change without prior notice Page 95 of 212 Ordering information Part no 20109407 20109409 Number of fibres 4 8 Cabe Type G4-9/125 AICI-I/O RM-W G8-9/125 AICI-I/O RM-W Fiber type Stock Item Fiber data sheet OS2 Single mode - C03e OS2 Single mode - C03e C03e 20109412 12 G12-9/125 AICI-I/O RM-W OS2 Single mode - 20117329 24 G24-9/125 AICI-I/O RM-W OS2 Single mode - C03e 20122674 4 G4-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C34 695442 8 G8-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C34 695452 12 G12-50/125 AICI-I/O RM-W OM2 50/125 multi mode - C34 C34 20110876 24 G24-50/125 AICI-I/O RM-W OM2 50/125 multi mode - 1019310 4 G4-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C31 C31 20109410 8 G8-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - 695453 12 G12-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C31 20117332 24 G24-50/125OM3BB AICI-I/O RM-W OM3 MaxCap-BB-OM3 - C31 20109408 4 G4-62.5/125 AICI-I/O RM-W OM1 62.5/125 multi mode Yes C02 20109411 8 G8-62.5/125 AICI-I/O RM-W OM1 62.5/125 multi mode Yes C02 OM1 62.5/125 multi mode - C02 OM1 62.5/125 multi mode - C02 20109413 20109414 12 24 G12-62.5/125 AICI-I/O RM-W G24-62.5/125 AICI-I/O RM-W OM4 and other fibre types on request. Colour code Fibre Colour no. 1 White 2 Red 3 Yellow 4 Green 5 Blue 6 Grey 7 Brown 8 Black Fibre no. 9 10 11 12 13 14 15 16 Colour Violet Turquise Orange Pink White + marker Red + marker Yellow + marker Green + marker Fibre no. 17 18 19 20 21 22 23 24 Colour Blue + marker Grey + marker Brown + marker Light Blue + marker Violet + marker Turquise + marker Orange + marker Pink + marker Standard colour of outer sheath is black. We reserve the right to alter this specification without notice. Subject to change without prior notice Page 96 of 212 Flame retardant optical fibre cable, AICI-I/O/RM/C-W, MUD PROTECTED Armoured industrial cable AICI-I/O/RM/C-W Indoor and outdoor Flame retardant and halogen free Steel wire braiding Tight buffer MUD PROTECTED Optical cable for industrial environments. The cable is suitable for both indoor and outdoor installation. Continiuous submergence in water is not recommended. Outer sheath (1) is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel and mineral oils. The resistance to these fluids is according to IEC60811-2-1. The cable is reinforced with a steel wire braiding between the two sheaths. Strength elements of glass yarn around the cable core allow easy installation of long lengths. The 0.9 mm tight buffer is easy to strip allowing fast and reliable splicing and connector mounting. Each fibre is colour coded for easy identification. The outer sheath is marked to show fibre type and cable type. Secondary coated fibre Water swellable material Glass yarn Inner sheath Steel wire braiding Outer sheath (1) Outer sheath (MUD) An additional outer sheath is added for improved oil- and MUD protection. The outer sheath is DARK GREY. Weight and dimensions Number of fibres Secondary coating Outer diameter Weight 4 8 12 24 [mm] 0.9 0.9 0.9 0.9 [mm] 10.2 11.4 12.4 14.0 [kg/km] 140 165 195 240 Tensile strength* [Inst./oper.] [N] 700/250 800/350 1200/500 1700/750 Cable properties *Tensile strength (IEC 60794-1-2E1) Max tensile load during installation Max tensile load during operation Crush (IEC 60794-1-2E3) Impact (IEC 60794-1-2E4) Torsion (IEC 60794-1-2E7) Cable bending Minimum bending diameter Cable bend (IEC 60794-1-2E11) Flexibility (IEC 60794-1-2E8) Temperature window See above See above Operation Installation Storage -40C to +70C -10C to +70C -40C to +70C 2000 N/10cm Water tightness* (IEC 60794-1-2F5B) 1 impacts, 25J Fire and smoke classifications 1 turn/1m IEC 60332-1 IEC 60332-3-22 (Cat. A) IEC 60332-3-24 (Cat. C) 15x outer diameter IEC 61034 <0.5 dB/ 5 turn IEC 60754-1 1000 cycles Chemical reistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) < 3 m/24 hours - 7 days /100°C - 7 days/100°C *) – Steel wire braiding is not watertight. Subject to change without prior notice Page 97 of 212 Ordering information Part no Number of fibres Cabe Type Fiber type Stock Item Fiber data sheet 20116218 * 4 G4-9/125 AICI-I/O/RM/C-W OS2 Single mode(G652D) - C03e 8 G8-9/125 AICI-I/O/RM/C-W OS2 Single mode(G652D) - C03e * 12 G12-9/125 AICI-I/O/RM/C-W OS2 Single mode(G652D) - C03e * 24 G24-9/125 AICI-I/O/RM/C-W OS2 Single mode(G652D) - C03e * 4 G4-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 * 8 G8-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 C23 886926 12 G12-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - * 24 G24-50/125 AICI-I/O/RM/C-W OM2 50/125 multi mode - C23 * 4 G4-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 C31 * 8 G8-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - * 12 G12-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 * 24 G24-50/125OM3 AICI-I/O/RM/C-W OM3 MaxCap-OM3 - C31 886701 4 G4-62.5/125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C02 C02 886774 8 G8-62.5/125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - * 12 G12-62.5/125 AICI-I/O/RM/C-W OM1 62.5/125 multi mode - C02 OM1 62.5/125 multi mode - C02 * 24 G24-62.5/125 AICI-I/O/RM/C-W Other fibre types/qualities on request(for example OM4) *) Part numbers will be given on request. On inquiries or orders, please refer to datasheet number D92aici-mud_e22.doc Colour code Fibre Colour no. 1 White 2 Red 3 Yellow 4 Green 5 Blue 6 Grey 7 Brown 8 Black Fibre no. 9 10 11 12 13 14 15 16 Colour Violet Turquise Orange Pink White + marker Red + marker Yellow + marker Green + marker Fibre no. 17 18 19 20 21 22 23 24 Colour Blue + marker Grey + marker Brown + marker Light Blue + marker Violet + marker Turquise + marker Orange + marker Pink + marker The outer sheath is as standard dark grey. Subject to change without prior notice Page 98 of 212 Optical fibre data sheet Fibre type 9/125 Fiber data sheet IEC60793-2-10, 20, 50 cat. IEC11801 classification ANSI/TIA/EIA classification ITU-T type Core diameter Mode field diameter Cladding diameter Primary coating diameter (nominal) Attenuation (Maximum values) 850 nm 1300 nm 1310 nm 1550 nm Bandwidth(OFL) 850 nm 1300 nm Chromatic Dispersion 1285-1330 nm 1550 nm 1625 nm Polarization Mode Disp. Max. Individual Fibre PMDQ Link Design Value Group index of refraction 850 nm 1300/1310 nm(MMF/SMF) 1550 nm 1625 nm 50/125-OM2 50/125-OM3 62.5/125-OM1 C03 B.1.3 OS2 CAAB G652.D C34 A1a.1 OM2 AAAB G651.1 C31 A1a.2 OM3 AAAC G651.1 C02 A1b OM1 AAAA - See mode field diameter 1310 nm 9.0 0.4 m 1550 nm 10.1 0.5 m 125 0.7 m 242 7 m 50 2.5 m 50 2.5 m 62.5 2.5 m 125 1.0 m 242 5 m 125 1.0 m 242 5 m 125 1.0 m 242 7 m 2.7 dB/km 0.8 dB/km 2.5 dB/km 0.8 dB/km 3.2 dB/km 1.0 dB/km >500 MHzkm >500 MHzkm >1500 MHzkm >500 MHzkm >200 MHzkm >600 MHzkm 1.482 1.477 1.496 1.491 0.39 dB/km 0.25 dB/km 3 ps/nmkm 18 ps/nmkm 22 ps/nmkm 0.5 ps/√km 0.2 ps/√km 1.467 1.468 1.468 1.482 1.477 Other fibrequalities/types and qualities are available on request, e.g. OM4 fibre. Subject to change without prior notice Page 99 of 212 ICS IE ToughCat 5e S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cabel is a Cat5e S/FTP cable meant for use as installation(horizontal) cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-2-1 ISO/IEC 11801; IEC 61156-5 Det Norske Veritas (DNV) spesification No. 6-827.50-2 and Lloyd Register approval system, 2002 Fire rating LSHF-FR(SHF1) : IEC 60754-2; IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) 4 hours/70°C Diesel - IRM 903 (IEC60811-2-1) 4 hours/70°C : 7 days/23°C : 7 days/23°C Certification This cable is certified by: Det Norske Veritas (DNV) and Lloyd Register. Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Sheath Stranded copper wire Ø 0.22 mm2 PE, Ø 1.4 mm 2 cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,2 mm Oil resistant, Fire retardant and halogen free LSHF-FR(SHF1). Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load Subject to change without prior notice Without load With load During operation During installation 4 pair During operation During installation 8xD 4xD -40°C to + 85°C -15°C to + 50°C 515 MJ/km No load 100 N Page 100 of 212 Electrical Properties at 20°C DC loop resistance Resistance unbalance Insulation resistance Capacitance Capacitance unbalance Mean Characteristic impedance Nominal velocity of propagation Propagation delay Delay skew Transfer impedance 158 Ω/km 2% 5000 MΩxkm Nom. 43 nF/km 1500 pF/km 100 ± 5 Ω 0,75c 450 ns/100 m 15 ns/100 m 10 mΩ /m 8 mΩ /m 10 mΩ /m 85 dB (500 V) at 800 Hz (pair to ground) @ 100 MHz) at 1 MHz at 10 MHz at 30 MHz Coupling attenuation Nominal Transmission characteristics at 20°C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) 1 (dB/100m) 2,1 (dB) 90 (dB/100m) 88 (dB) (dB) 87 (dB/100m) 85 (dB/100m) 85 (dB/100m) 82 4 4,0 90 86 27 87 83 85 82 10 6,3 90 84 30 87 81 79 76 16 8,0 90 82 30 87 79 75 72 20 9,0 90 81 30 87 78 73 70 31.25 11,4 90 79 30 87 76 69 66 62.50 16,5 86 70 30 83 67 63 60 100 21,3 83 62 30 80 59 59 56 155.00 24,2 81 57 26 78 54 57 54 200.00 31,5 78 47 25 75 44 53 50 250.00 35,8 77 41 25 74 38 51 48 300.00 47,1 73 26 23 70 23 47 44 600.00 60,1 71 11 20 68 8 44 41 Technical data Part no. 1000745 Description ToughCat5 S/FTP 4x2/0,22mm² Colour Grey RAL7035 Outer diameter mm 7,6 Fire load MJ/km 515 Weight kWh/m 0,143 kg/km 65 Product Code Table Product Description ToughCat C5e LSHF-FR 4x2/0.22mm2 ToughCat C5e LSHF-FR 4x2/0.22mm2 500DP ToughCat C5e LSHF-FR 4x2/0.22mm2 1000DP Subject to change without prior notice Product Code 1000745 1000745-00500DP 1000745-01000DP PG Reference Code 60011599 60011599 60011599 PG Part Number 60011599 60015830 60015833 Page 101 of 212 ICS IE ToughCat 7 S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-4-1 ISO/IEC 11801; IEC 61156-5 Det Norske Veritas (DNV) spesification No. 6-827.50-2 Fire rating LSHF-FR(SHF1) : IEC 60754-2; IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) : 7 days/23°C, 4 hours/70°C : 7 days/23°C, 4 hours/70°C Certification This cable is certified by: Det Norske Veritas (DNV) and American Bureau of Shipping (ABS) Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Sheath Stranded copper wire Ø 0.27 mm2 PE, Ø 1.6 mm 2 cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,6 mm Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load Subject to change without prior notice Without load With load During operation During installation 4 pair During operation During installation 8xD 4xD -40°C to + 85°C -15°C to + 50°C 670 MJ/km No load 100 N Page 102 of 212 Electrical Properties at 20°C DC loop resistance Resistance unbalance Insulation resistance Capacitance Capacitance unbalance Mean Characteristic impedance Nominal velocity of propagation Propagation delay Delay skew Transfer impedance 138 Ω/km 2% 5000 MΩxkm Nom. 43 nF/km 1500 pF/km 100 ± 5 Ω 0,76c 450 ns/100 m 15 ns/100 m 10 mΩ /m 8 mΩ /m 10 mΩ /m 85 dB (500 V) at 800 Hz (pair to ground) @ 100 MHz) at 1 MHz at 10 MHz at 30 MHz Coupling attenuation Nominal Transmission characteristics at 20°C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) 1 (dB/100m) 2,0 (dB) 90 (dB/100m) 88 (dB) (dB) 87 (dB/100m) 85 (dB/100m) 85 (dB/100m) 82 4 3,6 90 86 27 87 83 85 82 10 5,5 90 84 30 87 81 79 76 16 7,5 90 82 30 87 79 75 72 20 7,7 90 82 30 87 79 73 70 31.25 9,8 90 80 30 87 77 69 66 62.50 14,0 86 72 30 83 69 63 60 100 17,9 83 65 30 80 62 59 56 155.00 22,4 81 59 26 78 55 57 54 200.00 25,6 78 52 25 75 49 53 50 250.00 28,8 77 48 25 74 45 51 48 300.00 31,6 73 41 23 70 38 47 44 600.00 45,7 71 25 20 68 22 44 41 Technical data Part no. 1016274 Description ToughCat C7 LSHF-FR 4x2/0.27mm2 Colour Outer diamete r Grey RAL7035 mm 8,1 Fire load MJ/km 670 Weight kWh/m 0,186 kg/km 75 Product Code Table Product Description ToughCat C7 LSHF-FR 4x2/0.27mm2 ToughCat C7 LSHF-FR 4x2/0.27mm2 500DP ToughCat C7 LSHF-FR 4x2/0.27mm2 1000DP Subject to change without prior notice Product Code 1016274 1016274-00500DP PG Reference Code 60011617 60011617 60011617 PG Part Number 60011617 60015820 60030363 Page 103 of 212 ICS IE ToughCat 7S* S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments * Version with Solid conductors Application Generic Data transmission. This cable is a Cat7 S/FTP cable meant for use as installation/horizontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-4-1 ISO/IEC 11801; IEC 61156-5 Det Norske Veritas (DNV) specification No. 6-827.50-2 Fire rating LSHF-FR(SHF1) : IEC 60754-2; IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) : 7 days/23°C, 4 hours/70°C : 7 days/23°C, 4 hours/70°C Certification This cable is certified by: Det Norske Veritas (DNV) Construction Conductor Insulation Twisting Pair screen Cable lay up Screen Sheath Solid copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Al-laminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). Mechanical properties Bending radius Temperature range Fire load Maximum tensile load Subject to change without prior notice Without load With load During operation During installation 4 pair During operation During installation 8xD 4xD -40°C to + 85°C -15°C to + 50°C 670 MJ/km No load 200 N Page 104 of 212 Electrical properties at 20°C± 5°C Loop resistance Resistance unbalance Insulation resistance Mutual capacitance Capacitance unbalance Characteristic impedance 150 Ω/km 2% 5000 MΩ*km Nom. 43 nF/km 1500 pF/km 100 ± 5 Ω 100 ± 10 Ω 100 ± 15 Ω ca. 79 % 570 ns/100m 9 ns/100m 1000 V 10 mΩ/m 10 mΩ/m 10 mΩ/m 20 mΩ/m 85 dB (500 V) at 800 Hz (pair/ground) (1-100 MHz) (100 - 250) MHz (250 - 600) MHz Nominal velocity of propagation Propagation delay Delay skew Test voltage Transfer impedance(Grade 1) (DC, 1 min) core/core and core/screen at 1 MHz at 10 MHz at 30 MHz at 100MHz Coupling attenuation Electrical data (nominal) F (MHZ) 1,0 4,0 10,0 16,0 20,0 31,2 62,5 100,0 125,0 155,5 175,0 200,0 250,0 300,0 450,0 600,0 Attenuation (dB/100m) 1,8 3,4 5,4 6,8 7,7 9,6 13,7 17,4 19,5 21,9 23,3 25,0 28,1 30,9 38,3 44,8 acc. to Cat.7 (at 20°C) NEXT (dB) 100 100 100 100 100 100 100 100 95 94 93 92 90 89 87 85 PS-NEXT (dB) 97 97 97 97 97 97 97 97 92 91 90 89 87 86 84 82 ACR (dB/100m) 98 97 95 93 92 90 86 83 75 72 70 67 62 58 48 40 PS-ACR (dB/100m) 95 94 92 90 89 87 83 80 72 69 67 64 59 55 45 37 ELFEXT (dB/100m) 105 105 97 93 91 87 81 77 75 73 72 71 69 67 64 61 PS-ELFEXT (dB/100m) 105 102 94 90 88 84 78 74 72 70 69 68 66 64 61 58 Return loss (dB) 27 30 30 30 30 30 30 26 26 25 25 24 24 23 22 Technical data Part no. 1022322 Description ToughCat7S S/FTP 4x2/0.56 Colour Grey RAL7035 Outer diameter mm 7,6 Fire load MJ/km 670 Weight kWh/m 0,186 kg/km 64 Product Code Table Product Description ToughCat C7S LSHF-FR 4x2/0.56 ToughCat C7S LSHF-FR 4x2/0.56 500DP Subject to change without prior notice Product Code 1022322-00500DP PG Reference Code 60015280 60015280 PG Part Number 60015280 60015282 Page 105 of 212 ICS IE ToughCat 5e MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This Cat.5e S/FTP cable is based on our DNV and Lloyd Register certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-2-1 ISO/IEC 11801; IEC 61156-5 Fire rating MUD protecting outer sheath Inner sheath LSHF-FR(SHF1) : IEC 60754-2, IEC 61034, IEC 60332-3-24 : IEC 60754-2, IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) : 7 days/100°C : 7 days/100°C Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Inner sheath Outer sheath Stranded copper wire Ø 0.22 mm2 PE, Ø 1.4 mm 2 cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,2 mm Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1) Ø 7,7 mm MUD protecting Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load, installation Subject to change without prior notice Installation Installed During operation During installation 4 pair During installation Installed 8xD 4xD -40°C to + 85°C -15°C to + 50°C (On request) MJ/km 100 N No load Page 106 of 212 Electrical Properties at 20°C DC loop resistance Resistance unbalance Insulation resistance Capacitance Capacitance unbalance Mean Characteristic impedance Nominal velocity of propagation Propagation delay Delay skew Transfer impedance 158 Ω/km 2% 5000 MΩxkm Nom. 43 nF/km 300 pF/km 100 ± 5 Ω 0,75c 450 ns/100 m 15 ns/100 m 10 mΩ /m 8 mΩ /m 10 mΩ /m 85 dB (500 V) at 800 Hz (pair to ground) @ 100 MHz) at 1 MHz at 10 MHz at 30 MHz Coupling attenuation Nominal Transmission characteristics at 20°C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) 1 (dB/100m) 2,1 (dB) 90 (dB/100m) 88 (dB) (dB) 87 (dB/100m) 85 (dB/100m) 85 (dB/100m) 82 4 4,0 90 86 27 87 83 85 82 10 6,3 90 84 30 87 81 79 76 16 8,0 90 82 30 87 79 75 72 20 9,0 90 81 30 87 78 73 70 31.25 11,4 90 79 30 87 76 69 66 62.50 16,5 86 70 30 83 67 63 60 100 21,3 83 62 30 80 59 59 56 155.00 24,2 81 57 26 78 54 57 54 200.00 31,5 78 47 25 75 44 53 50 250.00 35,8 77 41 25 74 38 51 48 300.00 47,1 73 26 23 70 23 47 44 600.00 60,1 71 11 20 68 8 44 41 Technical data Part no. 1000846 Description ToughCat MUD C5e S/FTP P 4Px0.22mm2 Colour Dark Grey RAL7024 Outer diameter mm 9,6 Fire load MJ/km *) Weight kWh/m *) kg/km 100 *)-On request Product Code Table Product Description ToughCat MUD C5e S/FTP P 4Px0.22mm2 ToughCat MUD C5e S/FTP 4Px0.22mm2 500DP Subject to change without prior notice Product Code 100846 1000846-00500DP PG Reference Code 60015701 60015701 PG Part Number 60015701 60015703 Page 107 of 212 ICS IE ToughCat 7 MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments Application Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-4-1 ISO/IEC 11801; IEC 61156-5 Fire rating Inner sheath: LSHF-FR (SHF1) MUD protecting outer sheath : IEC 60754-2; IEC 61034, IEC 60332-3-24 : IEC 60754-2; IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) : - 7 days/100°C : - 7 days/100°C Certification Pending. Construction Conductor Insulation Twisting Cable lay up Pair screen Overall screen Inner sheath Outer sheath Stranded copper wire Ø 0.27 mm2 PE, Ø 1.6 mm 2 cores to the pair 4 pairs Al-laminated plastic foil around each pair Copper braid, tinned Ø 6,6 mm Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). MUD protecting Mechanical Properties Bending radius Temperature range Fire load Maximum tensile load Subject to change without prior notice Without load With load During operation During installation 4 pair During operation During installation 8xD 4xD -40°C to + 85°C -15°C to + 50°C (on request) MJ/km No load 100 N Page 108 of 212 Electrical Properties at 20°C DC loop resistance Resistance unbalance Insulation resistance Capacitance Capacitance unbalance Mean Characteristic impedance Nominal velocity of propagation Propagation delay Delay skew Transfer impedance 138 Ω/km 2% 5000 MΩxkm Nom. 43 nF/km 1500 pF/km 100 ± 5 Ω 0,76c 450 ns/100 m 15 ns/100 m 10 mΩ /m 8 mΩ /m 10 mΩ /m 85 dB (500 V) at 800 Hz (pair to ground) @ 100 MHz) at 1 MHz at 10 MHz at 30 MHz Coupling attenuation Nominal Transmission characteristics at 20°C F Attenuation NEXT ACR Return loss PS-NEXT PS-ACR ELFEXT PS-ELFEXT (MHz) 1 (dB/100m) 2,0 (dB) 90 (dB/100m) 88 (dB) (dB) 87 (dB/100m) 85 (dB/100m) 85 (dB/100m) 82 4 3,6 90 86 27 87 83 85 82 10 5,5 90 84 30 87 81 79 76 16 7,5 90 82 30 87 79 75 72 20 7,7 90 82 30 87 79 73 70 31.25 9,8 90 80 30 87 77 69 66 62.50 14,0 86 72 30 83 69 63 60 100 17,9 83 65 30 80 62 59 56 155.00 22,4 81 59 26 78 55 57 54 200.00 25,6 78 52 25 75 49 53 50 250.00 28,8 77 48 25 74 45 51 48 300.00 31,6 73 41 23 70 38 47 44 600.00 45,7 71 25 20 68 22 44 41 Technical data Part no. 1019269 Description ToughCat MUD C7 S/FTP 4Px0.27mm2 Colour Grey RAL7024 Outer diameter mm 10,1 Fire load MJ/km *) Weight kWh/m *) kg/km 112 *) on request Product Code Table Product Description ToughCat MUD C7 S/FTP 4Px0.27mm2 ToughCat MUD C7 S/FTP 4Px0.27mm2 500DP Subject to change without prior notice Product Code 1019269-00500DP PG Reference Code 60015692 60015692 PG Part Number 60015692 60015695 Page 109 of 212 ICS IE ToughCat 7S* MUD Protected S/FTP Installation cable for tougher environments S/FTP Installation Cable for tougher environments * Version with Solid conductors Application Generic Data transmission. This cable is a Cat7 S/FTP cable is based on our DNV certified ToughCat, but with an additional fire retardant, halogen-free, low smoke MUD protecting outer jacket. This cabel is meant for use as installation/horisontal cable in tougher electrical and mechanical environment, including ships and offshore units. Standards EN 50173-1; EN 50288-4-1 ISO/IEC 11801; IEC 61156-5 Fire rating Inner sheath: LSHF-FR (SHF1) MUD protecting outer sheath : IEC 60754-2; IEC 61034, IEC 60332-3-24 : IEC 60754-2; IEC 61034, IEC 60332-3-24 Chemical resistance Mineral oils IRM 902 (IEC60811-2-1) Diesel - IRM 903 (IEC60811-2-1) : - 7 days/100°C : - 7 days/100°C Certification The base construction(exclusive the extra MUD sheath) is certified by DnV. Construction Conductor Insulation Twisting Pair screen Cable lay up Screen Inner sheath Outer sheath Solid copper wire, Ø 0.56 mm (AWG 23) foamskin PE, Ø 1.4 mm 2 cores to the pair Al-laminated plastic foil 4 pairs (PiMF) to the core copper braid, tinned Oil resistant, Fire retardant and halogen free LSHF-FR (SHF1). MUD protecting Mechanical properties Bending radius Temperature range Fire load Maximum tensile load Subject to change without prior notice Without load With load During operation During installation 4 pair During operation During installation 8xD 4xD -40°C to + 85°C -15°C to + 50°C 670 MJ/km No load 200 N Page 110 of 212 Electrical properties at 20°C± 5°C Loop resistance Resistance unbalance Insulation resistance Mutual capacitance Capacitance unbalance Characteristic impedance 155 Ω/km 2% 5000 MΩ*km Nom. 43 nF/km 1500 pF/km 100 ± 5 Ω 100 ± 10 Ω 100 ± 15 Ω ca. 79 % 570 ns/100m 9 ns/100m 1000 V 10 mΩ/m 10 mΩ/m 10 mΩ/m 20 mΩ/m 85 dB (500 V) at 800 Hz (pair/ground) (1-100 MHz) (100 - 250) MHz (250 - 600) MHz Nominal velocity of propagation Propagation delay Delay skew Test voltage Transfer impedance(Grade 1) (DC, 1 min) core/core and core/screen at 1 MHz at 10 MHz at 30 MHz at 100MHz Coupling attenuation Electrical data (nominal) F (MHZ) 1,0 4,0 10,0 16,0 20,0 31,2 62,5 100,0 125,0 155,5 175,0 200,0 250,0 300,0 450,0 600,0 Attenuation (dB/100m) 1,8 3,4 5,4 6,8 7,7 9,6 13,7 17,4 19,5 21,9 23,3 25,0 28,1 30,9 38,3 44,8 acc. to Cat.7 (at 20°C) NEXT (dB) 100 100 100 100 100 100 100 100 95 94 93 92 90 89 87 85 PS-NEXT (dB) 97 97 97 97 97 97 97 97 92 91 90 89 87 86 84 82 ACR (dB/100m) 98 97 95 93 92 90 86 83 75 72 70 67 62 58 48 40 PS-ACR (dB/100m) 95 94 92 90 89 87 83 80 72 69 67 64 59 55 45 37 ELFEXT (dB/100m) 105 105 97 93 91 87 81 77 75 73 72 71 69 67 64 61 PS-ELFEXT (dB/100m) 105 102 94 90 88 84 78 74 72 70 69 68 66 64 61 58 Return loss (dB) 27 30 30 30 30 30 30 26 26 25 25 24 24 23 22 Technical data Part no. 1026769 *)-On request Description ToughCat MUD C7S 4x2/0.56 Colour Dark Grey RAL7024 Outer diameter mm 9,6 Fire load MJ/km *) Weight kWh/m *) kg/km 100 Product Code Table Product Description ToughCat MUD C7S 4x2/0.56 500DP ToughCat MUD C7S 4x2/0.56 Subject to change without prior notice Product Code 1026769-00500DP 1026769 PG Reference Code 60022014 60022014 PG Part Number 60015706 60022014 Page 111 of 212 ARCTIC GRADE instrumentation cable RFOU(i) 150/250(300)V, S1/S5 Flame retardant halogen-free instrumentation cable. Oil & Mud resistant. Cold bend / Cold impact resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Arctic Grade Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor Fixed installation for instrumentation, communication, IEC 60092-360 - Insulation Control and alarm systems in both EX- and safe areas. IEC 60092-360 - Sheath For installation in areas exposed to MUD and IEC 60332-1-2 - Flame Retardant drilling/cleaning fluids. Meets the OIL & MUD IEC 60332-3-22 - Flame Retardant resistance requirement in NEK TS 606:2009. Meets the IEC 60754-1,2 - Halogen Free cold bend / cold impact requirement in CSA 22.2 0.3IEC 61034-1,2 - Low Smoke 01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C CSA 22.2 0.3-01 (-40°C/-35°C) / -35°C. - Cold Bend / / IEC 60092-352 Annex E Cold Impact (-40°C/-35°C) Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU(I) 250V S1/S5 4PAIR 0.75mm2 IEC 60092376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel, Grey or Blue Subject to change without prior notice Page 112 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element Cross section core, mm² Conductor Diameter, mm Insulation Thickness, mm Thickness Inner covering, mm Diameter inner covering, mm Thickness Diameter Outer Braid Sheath, Wire, mm mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 2 2 4 4 8 8 16 16 24 24 2 2 2 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.9 1.9 2.1 2.1 7 ± 0.5 7 ± 0.5 10 ± 0.8 10 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 21.5 ± 1 21.5 ± 1 26.5 ± 1 26.5 ± 1 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.1 1.1 1.2 1.2 1.3 1.3 1.5 1.5 1.7 1.7 1.9 1.9 10 ± 0.8 10 ± 0.8 13 ± 0.8 13 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 26.5 ± 1 26.5 ± 1 31.5 ± 1.5 31.5 ± 1.5 185 185 280 280 430 430 690 690 1240 1240 1720 1720 54 54 85 85 166 166 265 265 439 439 596 596 1 1 2 2 4 4 8 8 16 16 24 24 3 3 3 3 3 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 2.1 2.1 2.5 2.5 7.5 ± 0.5 7.5 ± 0.5 11 ± 0.8 11 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 24.5 ± 1 24.5 ± 1 30.5 ± 1.5 30.5 ± 1.5 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.1 1.1 1.3 1.3 1.4 1.4 1.5 1.5 1.8 1.8 2 2 10.5 ± 0.8 10.5 ± 0.8 15 ± 0.8 15 ± 0.8 17 ± 0.8 17 ± 0.8 21.5 ± 1 21.5 ± 1 29.5 ± 1 29.5 ± 1 36 ± 1.5 36 ± 1.5 200 200 360 360 510 510 810 810 1540 1540 2240 2240 60 60 130 130 192 192 318 318 544 544 778 778 1 1 2 2 4 4 8 8 12 16 16 24 24 2 2 2 2 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.4 1.9 1.9 2.3 2.3 8 ± 0.5 8 ± 0.5 12 ± 0.8 12 ± 0.8 14 ± 0.8 14 ± 0.8 19 ± 0.8 19 ± 0.8 23 ± 1 26.5 ± 1 26.5 ± 1 33 ± 1.5 33 ± 1.5 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 1.1 1.1 1.3 1.3 1.4 1.4 1.6 1.6 1.8 1.9 1.9 2.2 2.2 11.5 ± 0.8 11.5 ± 0.8 16 ± 0.8 16 ± 0.8 18 ± 0.8 18 ± 0.8 23.5 ± 1 23.5 ± 1 28 ± 1 32 ± 1.5 32 ± 1.5 39 ± 1.5 39 ± 1.5 230 230 420 420 600 600 980 980 1380 1820 1820 2770 2770 71 71 168 168 252 252 420 420 580 740 740 1165 1165 1 1 2 4 4 8 8 16 16 24 24 3 3 3 3 3 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.1 1.1 1.1 2.3 2.3 2.5 2.5 8.5 ± 0.5 8.5 ± 0.5 13.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 21.5 ± 1 21.5 ± 1 31 ± 1.5 31 ± 1.5 38 ± 1.5 38 ± 1.5 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 1.1 1.1 1.4 1.5 1.5 1.7 1.7 2 2 2.3 2.3 12 ± 0.8 12 ± 0.8 17.5 ± 0.8 20 ± 1 20 ± 1 26 ± 1 26 ± 1 36.5 ± 1.5 36.5 ± 1.5 44 ± 2 44 ± 2 265 265 510 740 740 1230 1230 2410 2410 3550 3550 93 93 213 325 325 558 558 992 992 1551 1551 1 2 4 2 2 2 2.5 2.5 2.5 2 2 2 0.7 0.7 0.7 1.1 1.1 1.1 9 ± 0.5 0.2 13.5 ± 0.8 0.3 16 ± 0.8 0.3 1.1 1.4 1.5 12.5 ± 0.8 280 17.5 ± 0.8 530 20.5 ± 1 770 Subject to change without prior notice Page 113 of 212 99 225 350 Electrical values instrumentation cables Type Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded pair 2,5 mm² Shielded triple 2,5 mm² Shielded 16 and 24 triple 1,5 mm² Capacitance, approx. (nF/km) 110 110 125 125 145 145 105 Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 0,71 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 12,9 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 24,4 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 812000 812001 812006 812007 812018 812019 812030 812031 812042 812043 812048 812049 RFOU(I) 1PAIR 0.75mm² S1/S5 Cold RFOU(I) 1PAIR 0.75mm² S1/S5 Cold RFOU(I) 2PAIR 0.75mm² S1/S5 Cold RFOU(I) 2PAIR 0.75mm² S1/S5 Cold RFOU(I) 4PAIR 0.75mm² S1/S5 Cold RFOU(I) 4PAIR 0.75mm² S1/S5 Cold RFOU(I) 8PAIR 0.75mm² S1/S5 Cold RFOU(I) 8PAIR 0.75mm² S1/S5 Cold RFOU(I) 16PAIR 0.75mm² S1/S5 Cold RFOU(I) 16PAIR 0.75mm² S1/S5 Cold RFOU(I) 24PAIR 0.75mm² S1/S5 Cold RFOU(I) 24PAIR 0.75mm² S1/S5 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528120004 7021528120011 7021528120066 7021528120073 7021528120189 7021528120196 7021528120301 7021528120318 7021528120424 7021528120431 7021528120486 7021528120493 - 812060 812061 812066 812067 812078 812079 812090 812091 812102 812103 812108 812109 RFOU(I) 1TRIP 0.75mm² S1/S5 Cold RFOU(I) 1TRIP 0.75mm² S1/S5 Cold RFOU(I) 2TRIP 0.75mm² S1/S5 Cold RFOU(I) 2TRIP 0.75mm² S1/S5 Cold RFOU(I) 4TRIP 0.75mm² S1/S5 Cold RFOU(I) 4TRIP 0.75mm² S1/S5 Cold RFOU(I) 8TRIP 0.75mm² S1/S5 Cold RFOU(I) 8TRIP 0.75mm² S1/S5 Cold RFOU(I) 16TRIP 0.75mm² S1/S5 Cold RFOU(I) 16TRIP 0.75mm² S1/S5 Cold RFOU(I) 24TRIP 0.75mm² S1/S5 Cold RFOU(I) 24TRIP 0.75mm² S1/S5 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528120608 7021528120615 7021528120660 7021528120677 7021528120783 7021528120790 7021528120905 7021528120912 7021528121025 7021528121032 7021528121087 7021528121094 - 812200 812201 812206 812207 812218 812219 812230 812231 812236 812242 812243 812248 812249 RFOU(I) 1PAIR 1.5mm² S1/S5 Cold RFOU(I) 1PAIR 1.5mm² S1/S5 Cold RFOU(I) 2PAIR 1.5mm² S1/S5 Cold RFOU(I) 2PAIR 1.5mm² S1/S5 Cold RFOU(I) 4PAIR 1.5mm² S1/S5 Cold RFOU(I) 4PAIR 1.5mm² S1/S5 Cold RFOU(I) 8PAIR 1.5mm² S1/S5 Cold RFOU(I) 8PAIR 1.5mm² S1/S5 Cold RFOU(I) 12PAIR 1.5mm² S1/S5 Cold RFOU(I) 16PAIR 1.5mm² S1/S5 Cold RFOU(I) 16PAIR 1.5mm² S1/S5 Cold RFOU(I) 24PAIR 1.5mm² S1/S5 Cold RFOU(I) 24PAIR 1.5mm² S1/S5 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE - 7021528122008 7021528122015 7021528122060 7021528122077 7021528122183 7021528122190 7021528122305 7021528122312 7021528122367 7021528122428 7021528122435 7021528122480 7021528122497 - 812260 812261 812266 812278 812279 812290 812291 812302 812303 812308 812309 RFOU(I) 1TRIP 1.5mm² S1/S5 Cold RFOU(I) 1TRIP 1.5mm² S1/S5 Cold RFOU(I) 2TRIP 1.5mm² S1/S5 Cold RFOU(I) 4TRIP 1.5mm² S1/S5 Cold RFOU(I) 4TRIP 1.5mm² S1/S5 Cold RFOU(I) 8TRIP 1.5mm² S1/S5 Cold RFOU(I) 8TRIP 1.5mm² S1/S5 Cold RFOU(I) 16TRIP 1.5mm² S1/S5 Cold RFOU(I) 16TRIP 1.5mm² S1/S5 Cold RFOU(I) 24TRIP 1.5mm² S1/S5 Cold RFOU(I) 24TRIP 1.5mm² S1/S5 Cold GREY BLUE GREY GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528122602 7021528122619 7021528122664 7021528122787 7021528122794 7021528122909 7021528122916 7021528123029 7021528123036 7021528123081 7021528123098 - 812400 812406 812418 RFOU(I) 1PAIR 2.5mm² S1/S5 Cold RFOU(I) 2PAIR 2.5mm² S1/S5 Cold RFOU(I) 4PAIR 2.5mm² S1/S5 Cold GREY GREY GREY - 7021528124002 7021528124064 7021528124187 - Subject to change without prior notice Page 114 of 212 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 115 of 212 ARCTIC GRADE instrumentation cable RFOU(c) 150/250(300)V, S2/S6 Flame retardant halogen-free instrumentation cable. Oil & Mud resistant. Cold bend / Cold impact resistant RFOU(c) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS2/S6 Arctic Grade Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, Control and alarm systems in both EX- and safe areas. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092350 Clause 8.9 & Annex E at -40°C / -35°C. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/-35°C) / IEC 60092-352 Annex E (-40°C/35°C) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke - Cold Bend / Cold Impact Construction Code Letter Conductor Insulation R Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU(C) 250V S2/S6 4PAIR 0.75mm2 IEC 60092376 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel, Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Grey or Blue Page 116 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Number No of of cores in elements element Cross section core, mm² Conductor Diameter, mm Insulation Thickness, mm Thickness Inner covering, mm Diameter inner covering, mm Thickness Diameter Outer Braid Sheath, Wire, mm mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 2 2 4 4 8 8 16 16 24 24 2 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.1 1.1 1.9 1.9 2.1 2.1 10 ± 0.8 10 ± 0.8 11.5 ± 0.8 11.5 ± 0.8 15 ± 0.8 15 ± 0.8 20.5 ± 1 20.5 ± 1 25 ± 1 25 ± 1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 1.3 1.3 1.4 1.4 1.6 1.6 1.8 1.8 13.5 ± 0.8 13.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 25 ± 1 25 ± 1 29.5 ± 1 29.5 ± 1 275 275 390 390 600 600 1040 1040 1450 1450 81 81 138 138 223 223 358 358 510 510 2 2 4 4 8 8 16 24 24 3 3 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.1 1.1 2.1 2.3 2.3 11 ± 0.8 11 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 23 ± 1 28 ± 1 28 ± 1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 1.3 1.3 1.5 1.5 1.7 1.9 1.9 14.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 21 ± 1 21 ± 1 27.5 ± 1 33 ± 1.5 33 ± 1.5 320 320 470 470 740 740 1350 1860 1860 95 95 181 181 291 291 488 667 667 2 2 4 4 8 8 16 16 24 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.1 1.1 1.9 1.9 2.3 12 ± 0.8 12 ± 0.8 14 ± 0.8 14 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 31 ± 1.5 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.3 1.3 1.4 1.4 1.6 1.6 1.8 1.8 2.1 16 ± 0.8 16 ± 0.8 18 ± 0.8 18 ± 0.8 23 ± 1 23 ± 1 30 ± 1.5 30 ± 1.5 36.5 ± 1.5 410 410 560 560 890 890 1580 1580 2270 162 162 234 234 379 379 651 651 924 2 4 8 16 16 24 24 3 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 2.1 2.1 2.5 2.5 13 ± 0.8 15.5 ± 0.8 21 ± 1 28 ± 1 28 ± 1 35 ± 1.5 35 ± 1.5 0.3 0.3 0.3 0.3 0.3 0.4 0.4 1.4 1.4 1.7 1.9 1.9 2.2 2.2 17.5 ± 0.8 19.5 ± 0.8 25.5 ± 1 33 ± 1.5 33 ± 1.5 41 ± 2 41 ± 2 490 670 1140 2090 2090 3100 3100 190 291 517 903 903 1369 1369 2 4 4 12 2 2 2 2 2.5 2.5 2.5 2.5 2 2 2 2 0.7 0.7 0.7 0.7 1.1 1.1 1.1 2.1 13.5 ± 0.8 16 ± 0.8 16 ± 0.8 27 ± 1 0.3 0.3 0.3 0.3 1.4 1.4 1.4 1.8 17.5 ± 0.8 20 ± 1 20 ± 1 31.5 ± 1.5 490 680 680 1730 200 309 309 759 Subject to change without prior notice Page 117 of 212 Electrical values instrumentation cables Type Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² Unshielded 24 pair 2,5 mm² Unshielded 16 triple 2,5 mm² Capacitance, approx. (nF/km) 100 100 110 110 125 125 95 95 Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 0,66 0,66 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 8,02 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 36,8 36,8 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 812606 812607 812618 812619 812630 812631 812642 812643 812648 812649 RFOU(C) 2PAIR 0.75mm² S2/S6 Cold RFOU(C) 2PAIR 0.75mm² S2/S6 Cold RFOU(C) 4PAIR 0.75mm² S2/S6 Cold RFOU(C) 4PAIR 0.75mm² S2/S6 Cold RFOU(C) 8PAIR 0.75mm² S2/S6 Cold RFOU(C) 8PAIR 0.75mm² S2/S6 Cold RFOU(C) 16PAIR 0.75mm² S2/S6 Cold RFOU(C) 16PAIR 0.75mm² S2/S6 Cold RFOU(C) 24PAIR 0.75mm² S2/S6 Cold RFOU(C) 24PAIR 0.75mm² S2/S6 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528126068 7021528126075 7021528126181 7021528126198 7021528126303 7021528126310 7021528126426 7021528126433 7021528126488 7021528126495 - 812666 812667 812678 812679 812690 812691 812702 812708 812709 RFOU(C) 2TRIP 0.75mm² S2/S6 Cold RFOU(C) 2TRIP 0.75mm² S2/S6 Cold RFOU(C) 4TRIP 0.75mm² S2/S6 Cold RFOU(C) 4TRIP 0.75mm² S2/S6 Cold RFOU(C) 8TRIP 0.75mm² S2/S6 Cold RFOU(C) 8TRIP 0.75mm² S2/S6 Cold RFOU(C) 16TRIP 0.75mm² S2/S6 Cold RFOU(C) 24TRIP 0.75mm² S2/S6 Cold RFOU(C) 24TRIP 0.75mm² S2/S6 Cold GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE - 7021528126662 7021528126679 7021528126785 7021528126792 7021528126907 7021528126914 7021528127027 7021528127089 7021528127096 - 812806 812807 812818 812819 812830 812831 812842 812843 812848 RFOU(C) 2PAIR 1.5mm² S2/S6 Cold RFOU(C) 2PAIR 1.5mm² S2/S6 Cold RFOU(C) 4PAIR 1.5mm² S2/S6 Cold RFOU(C) 4PAIR 1.5mm² S2/S6 Cold RFOU(C) 8PAIR 1.5mm² S2/S6 Cold RFOU(C) 8PAIR 1.5mm² S2/S6 Cold RFOU(C) 16PAIR 1.5mm² S2/S6 Cold RFOU(C) 16PAIR 1.5mm² S2/S6 Cold RFOU(C) 24PAIR 1.5mm² S2/S6 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY - 7021528128062 7021528128079 7021528128185 7021528128192 7021528128307 7021528128314 7021528128420 7021528128437 7021528128482 - 812866 812878 812891 812902 812903 812908 812909 RFOU(C) 2TRIP 1.5mm² S2/S6 Cold RFOU(C) 4TRIP 1.5mm² S2/S6 Cold RFOU(C) 8TRIP 1.5mm² S2/S6 Cold RFOU(C) 16TRIP 1.5mm² S2/S6 Cold RFOU(C) 16TRIP 1.5mm² S2/S6 Cold RFOU(C) 24TRIP 1.5mm² S2/S6 Cold RFOU(C) 24TRIP 1.5mm² S2/S6 Cold GREY GREY BLUE GREY BLUE GREY BLUE - 7021528128666 7021528128789 7021528128918 7021528129021 7021528129038 7021528129083 7021528129090 - 813006 813018 813019 813036 RFOU(C) 2PAIR 2.5mm² S2/S6 Cold RFOU(C) 4PAIR 2.5mm² S2/S6 Cold RFOU(C) 4PAIR 2.5mm² S2/S6 Cold RFOU(C) 12PAIR 2.5mm² S2/S6 Cold GREY GREY BLUE GREY - 7021528130065 7021528130188 7021528130195 7021528130362 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 118 of 212 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(i) 150/250(300)V, S3/S7 Fire resistant, flame retardant halogen-free instrumentation cable. Oil & Mud resistant. Cold bend / Cold impact resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Arctic Grade Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at 40°C/-35°C. IEC 60092-376 (2003-05) - Design IEC 60228 class 2 - Conductor IEC 60092-360 - Insulation IEC 60092-360 - Sheath IEC 60332-1-2 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60331-1, -2, -21 - Fire Resistant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke CSA 22.2 0.3-01 (-40°C/-35°C) / - Cold Bend / IEC 60092-350 Annex E (Cold Impact 40°C/-35°C) Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU(I) 250V S3/S7 4PAIR 0.75mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 119 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 3.8 1.1 2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 10.2 1.3 2 2 0.75 1.1 0.6 1.1 11 ± 0.8 0.3 10.2 1.3 4 2 0.75 1.1 0.6 1.1 0.3 11.9 1.4 4 2 0.75 1.1 0.6 1.1 8 8 16 16 2 2 2 2 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 24 2 0.75 1.1 24 2 0.75 1 1 2 2 4 4 3 3 3 3 3 3 8 0.3 11.9 1.4 1.1 1.1 1.9 1.9 12.5 ± 0.8 12.5 ± 0.8 17 ± 0.8 17 ± 0.8 24 ± 1 24 ± 1 0.3 0.3 0.3 0.3 15.3 15.3 20.4 20.4 1.6 1.6 1.8 1.8 0.6 2.3 30 ± 1.5 0.3 25.4 2 1.1 0.6 2.3 30 ± 1.5 0.3 25.4 2 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 1.1 1.1 0.2 0.2 0.3 0.3 0.3 0.3 4.5 4.5 10.2 10.2 11.9 11.9 1.1 1.1 1.4 1.4 1.4 1.4 3 0.75 1.1 0.6 1.1 0.3 17.8 8 3 0.75 1.1 0.6 1.1 0.3 16 24 24 3 3 3 0.75 0.75 0.75 1.1 1.1 1.1 0.6 0.6 0.6 2.1 2.5 2.5 8 ± 0.5 8 ± 0.5 12 ± 0.8 12 ± 0.8 14 ± 0.8 14 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 26.5 ± 1 33 ± 1.5 33 ± 1.5 1 1 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 4 2 1.5 1.6 0.7 1.1 4 2 1.5 1.6 0.7 1.1 8 8 2 2 1.5 1.5 1.6 1.6 0.7 0.7 12 2 1.5 1.6 16 2 1.5 16 2 24 Diameter outer sheath, mm 10.5 ± 0.8 10.5 ± 0.8 14.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 21.5 ± 1 21.5 ± 1 29 ± 1 29 ± 1 35.5 ± 1.5 35.5 ± 1.5 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 200 54 200 54 360 133 360 133 490 183 490 183 780 780 1400 1400 283 283 465 465 2020 647 2020 647 11 ± 0.8 11 ± 0.8 16 ± 0.8 16 ± 0.8 18 ± 0.8 18 ± 0.8 225 225 410 410 570 570 68 68 146 146 209 209 1.7 23 ± 1 960 359 17.8 1.7 23 ± 1 960 359 0.3 0.4 0.4 22.9 36.2 36.2 1.9 2.2 2.2 32 ± 1.5 39 ± 1.5 39 ± 1.5 1770 2620 2620 594 909 909 0.2 0.2 0.3 0.3 4.5 4.5 11.9 11.9 1.1 1.1 1.4 1.4 79 79 184 184 0.3 13.6 1.5 670 269 0.3 13.6 1.5 670 269 0.3 0.3 17.8 17.8 1.7 1.7 1090 1090 446 446 0.7 1.4 25.5 ± 1 0.3 20.4 1.9 1560 606 1.6 0.7 2.1 30 ± 1.5 0.3 22.9 2 2080 766 1.5 1.6 0.7 2.1 30 ± 1.5 0.3 22.9 2 12 ± 0.8 12 ± 0.8 17 ± 0.8 17 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 25.5 ± 1 25.5 ± 1 30.5 ± 1.5 35.5 ± 1.5 35.5 ± 1.5 255 255 480 480 1.1 1.1 9 ± 0.5 9 ± 0.5 13 ± 0.8 13 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 21 ± 1 21 ± 1 2080 766 2 1.5 1.6 0.7 2.3 0.4 40.7 2.3 43 ± 2 3060 1211 24 2 1.5 1.6 0.7 2.3 0.4 40.7 2.3 43 ± 2 3060 1211 1 1 3 3 1.5 1.5 1.6 1.6 0.7 0.7 1.1 1.1 0.2 0.2 4.5 4.5 1.2 1.2 290 290 93 93 2 3 1.5 1.6 0.7 1.1 0.3 11.9 1.5 560 213 2 3 1.5 1.6 0.7 1.1 0.3 11.9 1.5 560 213 4 3 1.5 1.6 0.7 1.1 0.3 15.3 1.6 13 ± 0.8 13 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 21.5 ± 1 820 342 Subject to change without prior notice 36.5 ± 1.5 36.5 ± 1.5 9.5 ± 0.5 9.5 ± 0.5 14.5 ± 0.8 14.5 ± 0.8 17 ± 0.8 Page 120 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 4 8 8 3 3 3 1.5 1.5 1.5 1.6 1.6 1.6 0.7 0.7 0.7 1.1 1.1 1.1 16 3 1.5 1.6 0.9 2.3 16 3 1.5 1.6 0.9 2.3 24 24 3 3 1.5 1.5 1.6 1.6 0.9 0.9 2.7 2.7 1 1 2 2 2.5 2.5 2 2 0.7 0.7 1.1 1.1 2 2 2.5 2 0.7 1.1 4 8 2 2 2.5 2.5 2 2 0.7 0.7 1.1 1.1 16 2 2.5 2 0.9 2.3 1 3 2.5 2 0.7 1.1 8 3 2.5 2 0.7 12 3 2.5 2 0.7 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 17 ± 0.8 0.3 15.3 22.5 ± 1 0.3 20.4 22.5 ± 1 0.3 20.4 36.5 ± 0.4 36.2 1.5 36.5 ± 0.4 36.2 1.5 45.5 ± 2 0.4 45.2 45.5 ± 2 0.4 45.2 9.5 ± 0.5 9.5 ± 0.5 14.5 ± 0.8 17 ± 0.8 23.5 ± 1 36.5 ± 1.5 0.2 0.2 4.5 4.5 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1.6 1.8 1.8 21.5 ± 1 27.5 ± 1 27.5 ± 1 820 1380 1380 342 584 584 2.2 42.5 ± 2 3040 1125 2.2 42.5 ± 2 3040 1125 2.5 2.5 52 ± 2.5 52 ± 2.5 4370 4370 1598 1598 1.2 1.2 300 300 99 99 560 225 830 1390 367 633 3020 1222 350 129 1820 844 2930 1284 0.3 11.9 1.5 0.3 0.3 15.3 20.4 1.6 1.8 13 ± 0.8 13 ± 0.8 18.5 ± 0.8 21.5 ± 1 28 ± 1 0.4 36.2 2.2 42.5 ± 2 10.5 ± 0.8 0.2 5.3 1.2 1.3 25.5 ± 1 0.3 22.9 2 2.6 33.5 ± 1.5 0.4 36.2 2.2 13.5 ± 0.8 30.5 ± 1.5 39.5 ± 1.5 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded pair 2,5 mm² Shielded triple 2,5 mm² Shielded 16 and 24 triple 1,5 mm² Shielded 16 pair 2,5 mm² 110 110 125 125 145 145 105 110 0,67 0,67 0,63 0,63 0,59 0,59 0,71 0,66 26,3 26,3 12,9 12,9 8,02 8,02 12,9 8,02 12,7 12,7 24,4 24,4 36,8 36,8 24,4 41,1 Ordering information New Part number Old Part number 20110770 Description Sheath Colour Stock item EAN No. DNK EL No. 813201 813206 813207 813218 813219 813230 813231 813242 813243 813248 813249 BFOU(I) 1PAIR 0.75mm² S3/S7 Cold BFOU(I) 1PAIR 0.75mm² S3/S7 Cold BFOU(I) 2PAIR 0.75mm² S3/S7 Cold BFOU(I) 2PAIR 0.75mm² S3/S7 Cold BFOU(I) 4PAIR 0.75mm² S3/S7 Cold BFOU(I) 4PAIR 0.75mm² S3/S7 Cold BFOU(I) 8PAIR 0.75mm² S3/S7 Cold BFOU(I) 8PAIR 0.75mm² S3/S7 Cold BFOU(I) 16PAIR 0.75mm² S3/S7 Cold BFOU(I) 16PAIR 0.75mm² S3/S7 Cold BFOU(I) 24PAIR 0.75mm² S3/S7 Cold BFOU(I) 24PAIR 0.75mm² S3/S7 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528132007 7021528132014 7021528132069 7021528132076 7021528132182 7021528132199 7021528132304 7021528132311 7021528132427 7021528132434 7021528132489 7021528132496 - 813260 813261 813266 813267 813278 813279 813290 813291 813302 813308 813309 BFOU(I) 1TRIP 0.75mm² S3/S7 Cold BFOU(I) 1TRIP 0.75mm² S3/S7 Cold BFOU(I) 2TRIP 0.75mm² S3/S7 Cold BFOU(I) 2TRIP 0.75mm² S3/S7 Cold BFOU(I) 4TRIP 0.75mm² S3/S7 Cold BFOU(I) 4TRIP 0.75mm² S3/S7 Cold BFOU(I) 8TRIP 0.75mm² S3/S7 Cold BFOU(I) 8TRIP 0.75mm² S3/S7 Cold BFOU(I) 16TRIP 0.75mm² S3/S7 Cold BFOU(I) 24TRIP 0.75mm² S3/S7 Cold BFOU(I) 24TRIP 0.75mm² S3/S7 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE - 7021528132601 7021528132618 7021528132663 7021528132670 7021528132786 7021528132793 7021528132908 7021528132915 7021528133028 7021528133080 7021528133097 - Subject to change without prior notice Page 121 of 212 New Part number 20113810 20126333 20110771 Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 813407 813418 813419 813430 813431 813436 813442 813443 813448 813449 BFOU(I) 1PAIR 1.5mm² S3/S7 Cold BFOU(I) 1PAIR 1.5mm² S3/S7 Cold BFOU(I) 2PAIR 1.5mm² S3/S7 Cold BFOU(I) 2PAIR 1.5mm² S3/S7 Cold BFOU(I) 4PAIR 1.5mm² S3/S7 Cold BFOU(I) 4PAIR 1.5mm² S3/S7 Cold BFOU(I) 8PAIR 1.5mm² S3/S7 Cold BFOU(I) 8PAIR 1.5mm² S3/S7 Cold BFOU(I) 12PAIR 1.5mm² S3/S7 Cold BFOU(I) 16PAIR 1.5mm² S3/S7 Cold BFOU(I) 16PAIR 1.5mm² S3/S7 Cold BFOU(I) 24PAIR 1.5mm² S3/S7 Cold BFOU(I) 24PAIR 1.5mm² S3/S7 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE Yes - 7021528134001 7021528134018 7021528134063 7021528134070 7021528134186 7021528134193 7021528134308 7021528134315 7021528134360 7021528134421 7021528134438 7021528134483 7021528134490 - 813461 813466 813467 813478 813479 813490 813491 813502 813503 813508 813509 BFOU(I) 1TRIP 1.5mm² S3/S7 Cold BFOU(I) 1TRIP 1.5mm² S3/S7 Cold BFOU(I) 2TRIP 1.5mm² S3/S7 Cold BFOU(I) 2TRIP 1.5mm² S3/S7 Cold BFOU(I) 4TRIP 1.5mm² S3/S7 Cold BFOU(I) 4TRIP 1.5mm² S3/S7 Cold BFOU(I) 8TRIP 1.5mm² S3/S7 Cold BFOU(I) 8TRIP 1.5mm² S3/S7 Cold BFOU(I) 16TRIP 1.5mm² S3/S7 Cold BFOU(I) 16TRIP 1.5mm² S3/S7 Cold BFOU(I) 24TRIP 1.5mm² S3/S7 Cold BFOU(I) 24TRIP 1.5mm² S3/S7 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528134605 7021528134612 7021528134667 7021528134674 7021528134780 7021528134797 7021528134902 7021528134919 7021528135022 7021528135039 7021528135084 7021528135091 - 813600 813601 813606 813618 813630 813642 BFOU(I) 1PAIR 2.5mm² S3/S7 Cold BFOU(I) 1PAIR 2.5mm² S3/S7 Cold BFOU(I) 2PAIR 2.5mm² S3/S7 Cold BFOU(I) 4PAIR 2.5mm² S3/S7 Cold BFOU(I) 8PAIR 2.5mm² S3/S7 Cold BFOU(I) 16PAIR 2.5mm² S3/S7 Cold GREY BLUE GREY GREY GREY GREY - 7021528136005 7021528136012 7021528136067 7021528136180 7021528136302 7021528136425 - 813660 813690 813696 BFOU(I) 1TRIP 2.5mm² S3/S7 Cold BFOU(I) 8TRIP 2.5mm² S3/S7 Cold BFOU(I) 12TRIP 2.5mm² S3/S7 Cold GREY GREY GREY - 7021528136609 7021528136906 7021528136968 - 20126334 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 122 of 212 ARCTIC GRADE Fire resistant, instrumentation cable BFOU(c) 150/250(300)V, S4/S8 Fire resistant, flame retardant halogen-free instrumentation cable. Oil & Mud resistant. Cold bend / Cold impact resistant BFOU(c) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS4/S8 Arctic Grade Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the OIL & MUD resistance requirement in NEK TS 606:2009. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at 40°C/-35°C. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/-35°C) / IEC 60092-350 Annex E (-40°C/35°C) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke - Cold Bend / Cold Impact Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU(C) 250V S4/S8 4PAIR 0.75mm2 FLEX FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel Marking text Manufacturing unit Outer sheath colour Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 123 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 2 0.75 1.1 0.6 1.1 2 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 16 16 2 2 0.75 0.75 1.1 1.1 0.6 0.6 24 2 0.75 1.1 24 2 0.75 2 2 4 4 3 3 3 3 8 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 340 113 340 113 0.3 13.6 1.5 20.5 ± 1 680 240 1.9 1.9 10.5 ± 0.8 10.5 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 22 ± 1 22 ± 1 0.3 0.3 17.8 17.8 1.7 1.7 1180 1180 383 383 0.6 2.3 27.5 ± 1 0.3 22.9 2 1700 536 1.1 0.6 2.3 27.5 ± 1 0.3 22.9 2 27 ± 1 27 ± 1 32.5 ± 1.5 32.5 ± 1.5 1700 536 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.6 1.1 1.1 1.1 1.1 0.3 0.3 0.3 0.3 10.2 10.2 11.9 11.9 1.3 1.3 1.4 1.4 16 ± 0.8 16 ± 0.8 18 ± 0.8 18 ± 0.8 400 400 550 550 143 143 198 198 3 0.75 1.1 0.6 1.1 0.3 15.3 1.6 23 ± 1 870 308 8 3 0.75 1.1 0.6 1.1 12 ± 0.8 12 ± 0.8 14 ± 0.8 14 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 0.3 15.3 1.6 23 ± 1 870 308 16 3 0.75 1.1 0.6 2.1 25.5 ± 1 0.3 20.4 1.8 1560 513 16 3 0.75 1.1 0.6 2.1 25.5 ± 1 0.3 20.4 1.8 1560 513 31.5 ± 1.5 0.4 36.2 2.1 2350 822 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 10.2 10.2 11.9 11.9 17.8 17.8 20.4 22.9 22.9 1.4 1.4 1.4 1.4 1.7 1.7 1.8 1.9 1.9 450 450 600 600 990 990 1350 1740 1740 162 162 234 234 404 404 540 677 677 0.4 36.2 2.2 2610 1030 0.4 36.2 2.2 2610 1030 0.3 11.9 1.4 540 207 540 207 760 760 1270 1270 307 307 517 517 1760 736 2540 1034 24 3 0.75 1.1 0.6 2.5 2 2 4 4 8 8 12 16 16 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 1.1 1.1 1.1 1.1 1.1 1.1 1.4 1.9 1.9 24 2 1.5 1.6 0.7 2.3 24 2 1.5 1.6 0.7 2.3 2 3 1.5 1.6 0.7 1.1 2 3 1.5 1.6 0.7 1.1 4 4 8 8 3 3 3 3 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 0.7 0.7 0.7 0.7 12 3 1.5 1.6 16 3 1.5 16 3 24 3 13 ± 0.8 13 ± 0.8 15 ± 0.8 15 ± 0.8 20 ± 1 20 ± 1 24 ± 1 27 ± 1 27 ± 1 33.5 ± 1.5 33.5 ± 1.5 8.5 1.3 0.3 8.5 1.3 0.3 10.2 1.3 16 ± 0.8 440 155 0.3 10.2 1.3 16 ± 0.8 440 155 0.3 13.6 1.5 20.5 ± 1 680 240 0.3 11.9 1.4 1.1 1.1 1.1 1.1 14.5 ± 0.8 14.5 ± 0.8 17 ± 0.8 17 ± 0.8 22.5 ± 1 22.5 ± 1 0.3 0.3 0.3 0.3 13.6 13.6 17.8 17.8 1.5 1.5 1.8 1.8 0.7 1.4 27 ± 1 0.3 22.9 1.9 1.6 0.7 2.3 0.4 36.2 2.1 1.5 1.6 0.7 2.3 1.5 1.6 0.7 2.7 Subject to change without prior notice 31.5 ± 1.5 31.5 ± 1.5 38.5 ± 14.5 ± 0.8 14.5 ± 0.8 0.3 0.4 36.2 2.1 0.4 40.7 2.4 30.5 ± 1.5 30.5 ± 1.5 37.5 ± 1.5 17 ± 0.8 17 ± 0.8 19 ± 0.8 19 ± 0.8 25 ± 1 25 ± 1 29 ± 1 32 ± 1.5 32 ± 1.5 39.5 ± 1.5 39.5 ± 1.5 18.5 ± 0.8 18.5 ± 0.8 21 ± 1 21 ± 1 27.5 ± 1 27.5 ± 1 32.5 ± 1.5 37.5 ± 1.5 37.5 ± 1.5 45 ± 2 2540 1034 3560 1421 Page 124 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 2 2.5 2 0.7 1.1 4 2 2.5 2 0.7 1.1 8 16 24 2 2 2 2.5 2.5 2.5 2 2 2 0.7 0.9 0.9 1.1 2.3 2.7 8 3 2.5 2 0.7 1.1 16 3 2.5 2 0.9 2.6 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 1.5 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 14 ± 0.8 16.5 ± 0.8 22 ± 1 33 ± 1.5 41 ± 2 0.3 11.9 1.4 18 ± 0.8 530 217 0.3 13.6 1.5 20.5 ± 1 740 325 0.3 0.4 0.4 17.8 31.7 40.7 1.8 2.1 2.4 27 ± 1 39 ± 1.5 47.5 ± 2 1230 2590 3760 551 1054 1511 25 ± 1 38.5 ± 1.5 0.3 20.4 1.9 30 ± 1.5 1620 762 0.4 36.2 2.3 44.5 ± 2 3550 1473 Electrical values instrumentation cables Type Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² Unshielded 16 and 24 pair 2,5 mm² Unshielded 12, 16 and 24 triple 2,5 mm² Capacitance, approx. Inductance, approx, (nF/km) (mH/km) 100 0,67 100 0,67 110 0,63 110 0,63 125 0,59 125 0,59 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 95 0,66 8,02 36,8 95 0,66 8,02 36,8 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 813806 813807 813818 813819 813830 813831 813842 813843 813848 813849 BFOU(C) 2PAIR 0.75mm² S4/S8 Cold BFOU(C) 2PAIR 0.75mm² S4/S8 Cold BFOU(C) 4PAIR 0.75mm² S4/S8 Cold BFOU(C) 4PAIR 0.75mm² S4/S8 Cold BFOU(C) 8PAIR 0.75mm² S4/S8 Cold BFOU(C) 8PAIR 0.75mm² S4/S8 Cold BFOU(C) 16PAIR 0.75mm² S4/S8 Cold BFOU(C) 16PAIR 0.75mm² S4/S8 Cold BFOU(C) 24PAIR 0.75mm² S4/S8 Cold BFOU(C) 24PAIR 0.75mm² S4/S8 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528138061 7021528138078 7021528138184 7021528138191 7021528138306 7021528138313 7021528138429 7021528138436 7021528138481 7021528138498 - 813866 813867 813878 813879 813890 813891 813902 813903 813908 BFOU(C) 2TRIP 0.75mm² S4/S8 Cold BFOU(C) 2TRIP 0.75mm² S4/S8 Cold BFOU(C) 4TRIP 0.75mm² S4/S8 Cold BFOU(C) 4TRIP 0.75mm² S4/S8 Cold BFOU(C) 8TRIP 0.75mm² S4/S8 Cold BFOU(C) 8TRIP 0.75mm² S4/S8 Cold BFOU(C) 16TRIP 0.75mm² S4/S8 Cold BFOU(C) 16TRIP 0.75mm² S4/S8 Cold BFOU(C) 24TRIP 0.75mm² S4/S8 Cold GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY - 7021528138665 7021528138672 7021528138788 7021528138795 7021528138900 7021528138917 7021528139020 7021528139037 7021528139082 - 814006 814007 814018 814019 814031 814036 814042 814043 814048 814049 BFOU(C) 2PAIR 1.5mm² S4/S8 Cold BFOU(C) 2PAIR 1.5mm² S4/S8 Cold BFOU(C) 4PAIR 1.5mm² S4/S8 Cold BFOU(C) 4PAIR 1.5mm² S4/S8 Cold BFOU(C) 8PAIR 1.5mm² S4/S8 Cold BFOU(C) 8PAIR 1.5mm² S4/S8 Cold BFOU(C) 12PAIR 1.5mm² S4/S8 Cold BFOU(C) 16PAIR 1.5mm² S4/S8 Cold BFOU(C) 16PAIR 1.5mm² S4/S8 Cold BFOU(C) 24PAIR 1.5mm² S4/S8 Cold BFOU(C) 24PAIR 1.5mm² S4/S8 Cold GREY BLUE GREY BLUE GREY BLUE GREY GREY BLUE GREY BLUE Yes - 7021528140064 7021528140071 7021528140187 7021528140194 7021528140309 7021528140316 7021528140361 7021528140422 7021528140439 7021528140484 7021528140491 - 814066 814067 814078 BFOU(C) 2TRIP 1.5mm² S4/S8 Cold BFOU(C) 2TRIP 1.5mm² S4/S8 Cold BFOU(C) 4TRIP 1.5mm² S4/S8 Cold GREY BLUE GREY - 7021528140668 7021528140675 7021528140781 - 20116213 Subject to change without prior notice Page 125 of 212 New Part number Old Part number 814079 814090 814091 814096 814102 814103 814108 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU(C) 4TRIP 1.5mm² S4/S8 Cold BFOU(C) 8TRIP 1.5mm² S4/S8 Cold BFOU(C) 8TRIP 1.5mm² S4/S8 Cold BFOU(C) 12TRIP 1.5mm² S4/S8 Cold BFOU(C) 16TRIP 1.5mm² S4/S8 Cold BFOU(C) 16TRIP 1.5mm² S4/S8 Cold BFOU(C) 24TRIP 1.5mm² S4/S8 Cold BLUE GREY BLUE GREY GREY BLUE GREY - 7021528140798 7021528140903 7021528140910 7021528140965 7021528141023 7021528141030 7021528141085 - 814206 814218 814230 814242 814248 BFOU(C) 2PAIR 2.5mm² S4/S8 Cold BFOU(C) 4PAIR 2.5mm² S4/S8 Cold BFOU(C) 8PAIR 2.5mm² S4/S8 Cold BFOU(C) 16PAIR 2.5mm² S4/S8 Cold BFOU(C) 24PAIR 2.5mm² S4/S8 Cold GREY GREY GREY GREY GREY - 7021528142068 7021528142181 7021528142303 7021528142426 7021528142488 - 814290 814302 BFOU(C) 8TRIP 2.5mm² S4/S8 Cold BFOU(C) 16TRIP 2.5mm² S4/S8 Cold GREY GREY - 7021528142907 7021528143027 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 126 of 212 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8 Flame retardant halogen-free power cable. Oil & Mud resistant. Cold bend / Cold impact resistant RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Arctic Grade Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 Application - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas IEC 60332-1-2 exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold IEC 60332-3-22 bend / cold impact requirement in CSA 22.2 0.3-01 and IEC IEC 60754-1,2 60092-350 clause 8.9 & Annex E at -40°C / -35°C. IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/-35°C) - Cold Bend / / IEC 60092-352 Annex E Cold Impact (-40°C/-35°C) Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-359) E.g. "meter" "year" DRAKA 01 RFOU 0.6/1kV P1/P8 3 x 95/50mm2 IEC 603323-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel, Black Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Page 127 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 - Range and dimensions Cross Number section of core, elements mm² Electrical Thickness Conductor Insulation Cross Inner Diameter, Thickness, section covering, mm mm braid, mm² mm Diameter inner covering, mm Thickness Diameter Outer Braid Sheath, Wire, mm mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 2.5 4 6 6 10 10 10 10 10 16 16 5.15 6.45 7.65 9.0 10.85 12.60 14.20 15.90 17.70 20.15 22.60 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.2 9.5 ± 0.5 11.5 ± 0.8 12.5 ± 0.8 14.5 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 20.5 ± 1 22.5 ± 1 24.5 ± 1 27.5 ± 1 30.5 ± 1.5 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 13 ± 0.8 15 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 21 ± 1 23 ± 1 25 ± 1 27 ± 1 29.5 ± 1 33 ± 1.5 35.5 ± 1.5 370 490 660 840 1120 1400 1730 2070 2490 3140 3830 190 283 413 534 757 973 1231 1507 1838 2365 2959 2 3 4 5 7 12 19 27 37 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 4 4 6 6 6 10 10 10 16 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 9.5 ± 0.5 10 ± 0.8 11 ± 0.8 12 ± 0.8 12 ± 0.8 16 ± 0.8 19 ± 0.8 22.5 ± 1 25 ± 1 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.2 1.3 1.3 1.3 1.5 1.6 1.8 1.9 13 ± 0.8 13.5 ± 0.8 15 ± 0.8 16 ± 0.8 16 ± 0.8 20 ± 1 23.5 ± 1 27.5 ± 1 30.5 ± 1.5 275 300 380 450 490 720 1000 1320 1680 80 94 139 170 198 301 415 550 716 2 3 4 5 7 12 19 27 37 3G 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 6 6 6 6 10 10 16 16 - 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.4 1.1 10.5 ± 0.8 11 ± 0.8 12 ± 0.8 13.5 ± 0.8 13.5 ± 0.8 18 ± 0.8 21 ± 1 25 ± 1 29 ± 1 11 ± 0.8 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.3 1.3 1.4 1.4 1.6 1.7 1.9 2 1.3 14 ± 0.8 15 ± 0.8 16 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 22.5 ± 1 26 ± 1 30.5 ± 1.5 34 ± 1.5 15 ± 0.8 320 400 470 540 620 930 1290 1720 2240 400 98 152 192 214 277 426 611 819 1074 152 2 3 4 5 3G 4G 12 20 4 4 4 4 4 4 4 4 6 6 6 6 10 16 2.55 2.55 2.55 2.55 2.55 2.55 2.55 2.55 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 11.5 ± 0.8 12 ± 0.8 13.5 ± 0.8 14.5 ± 0.8 12 ± 0.8 13.5 ± 0.8 20 ± 1 25 ± 1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.3 1.3 1.4 1.4 1.3 1.4 1.7 1.9 15.5 ± 0.8 16 ± 0.8 17.5 ± 0.8 19 ± 0.8 16 ± 0.8 17.5 ± 0.8 24.5 ± 1 30.5 ± 1.5 420 490 570 670 490 570 1200 1830 157 210 247 300 210 247 616 935 2 3 4 3G 4G 5G 6 6 6 6 6 6 6 6 6 - 3.15 3.15 3.15 3.15 3.15 3.15 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.1 12.5 ± 0.8 13.5 ± 0.8 15 ± 0.8 13.5 ± 0.8 15 ± 0.8 16.5 ± 0.8 0.3 0.3 0.3 0.3 0.3 0.3 1.3 1.4 1.4 1.4 1.4 1.5 16.5 ± 0.8 17.5 ± 0.8 19 ± 0.8 17.5 ± 0.8 19 ± 0.8 20.5 ± 1 510 590 700 590 700 820 209 264 335 264 335 390 2 3 10 10 10 10 4.05 4.05 1.0 1.0 1.1 1.1 14.5 ± 0.8 0.3 15.5 ± 0.8 0.3 1.4 1.4 18.5 ± 0.8 670 19.5 ± 0.8 790 300 391 Subject to change without prior notice Page 128 of 212 Cross Number section of core, elements mm² 4 10 4G 10 5G 10 Electrical Cross section braid, mm² 10 - Thickness Conductor Insulation Inner Diameter, Thickness, covering, mm mm mm 4.05 1.0 1.1 4.05 1.0 1.1 4.05 1.0 1.2 Diameter inner covering, mm 17 ± 0.8 17 ± 0.8 19 ± 0.8 Thickness Diameter Outer Braid Sheath, Wire, mm mm 0.3 1.5 0.3 1.5 0.3 1.5 Diameter outer sheath, mm 21.5 ± 1 21.5 ± 1 23 ± 1 Weight of Cable Approx. (Kg/Km) 950 950 1140 Copper content Approx. (kg/km) 496 496 603 2 3 4 3G 4G 5G 16 16 16 16 16 16 16 16 16 - 5.15 5.15 5.15 5.15 5.15 5.15 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.1 1.2 1.2 16.5 ± 0.8 18 ± 0.8 20 ± 1 18 ± 0.8 20 ± 1 22 ± 1 0.4 0.4 0.4 0.3 0.3 0.3 1.5 1.5 1.6 1.5 1.6 1.6 21.5 ± 1 22.5 ± 1 24.5 ± 1 22 ± 1 24.5 ± 1 26.5 ± 1 950 1120 1400 1060 1320 1570 481 626 806 571 734 905 2 3 4 4G 5G 25 25 25 25 25 16 16 16 - 6.45 6.45 6.45 6.45 6.45 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 20.5 ± 1 22 ± 1 24.5 ± 1 24.5 ± 1 27 ± 1 0.4 0.3 0.3 0.3 0.3 1.6 1.6 1.7 1.7 1.8 25.5 ± 1 26.5 ± 1 29 ± 1 29 ± 1 31.5 ± 1.5 1340 1570 1920 1890 2270 685 893 1125 1100 1356 2 3 4 4G 5G 35 35 35 35 35 16 16 16 - 7.65 7.65 7.65 7.65 7.65 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 23 ± 1 24.5 ± 1 27 ± 1 27 ± 1 30 ± 1.5 0.3 0.3 0.3 0.3 0.3 1.7 1.7 1.8 1.8 1.9 27.5 ± 1 29 ± 1 32 ± 1.5 32 ± 1.5 35 ± 1.5 1600 1940 2390 2390 2860 828 1142 1456 1456 1795 3 4 4G 5G 50 50 50 50 25 25 - 9.0 9.0 9.0 9.0 1.4 1.4 1.4 1.4 1.2 1.4 1.4 1.4 28.5 ± 1 32 ± 1.5 32 ± 1.5 35 ± 1.5 0.4 0.4 0.3 0.4 1.9 2 2 2.1 34 ± 1.5 37.5 ± 1.5 37.5 ± 1.5 41 ± 2 2690 3310 3230 4010 1617 2052 1970 2531 2 3 4 4G 70 70 70 70 35 35 35 - 10.85 10.85 10.85 10.85 1.4 1.4 1.4 1.4 1.2 1.4 1.4 1.4 30.5 ± 1.5 33 ± 1.5 36.5 ± 1.5 36.5 ± 1.5 0.6 0.5 0.5 0.4 1.9 2 2.2 2.2 36.5 ± 1.5 39 ± 1.5 43 ± 2 42.5 ± 2 3040 3720 4580 4450 1782 2385 3018 2888 2 3 4 4G 95 95 95 95 50 50 50 - 12.60 12.60 12.60 12.60 1.6 1.6 1.6 1.6 1.4 1.4 1.4 1.4 35 ± 1.5 37.5 ± 1.5 41.5 ± 2 41.5 ± 2 0.6 0.5 0.5 0.4 2.1 2.2 2.4 2.4 41.5 ± 2 43.5 ± 2 48.5 ± 2 48 ± 2 3940 4810 6000 5770 2317 3126 4020 3796 2 3 4 120 120 120 60 60 60 14.20 14.20 14.20 1.6 1.6 1.6 1.4 1.4 1.6 38 ± 1.5 41 ± 2 46 ± 2 0.6 0.6 0.6 2.2 2.3 2.5 45 ± 2 4790 48 ± 2 5930 53.5 ± 2.5 7420 2891 3975 5100 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 810000 810001 810002 810003 810004 810005 810006 810007 810008 810009 810010 RFOU 0.6/1kV 1X16/2.5 P1/P8 Cold RFOU 0.6/1kV 1X25/4 P1/P8 Cold RFOU 0.6/1kV 1X35/6 P1/P8 Cold RFOU 0.6/1kV 1X50/6 P1/P8 Cold RFOU 0.6/1kV 1X70/10 P1/P8 Cold RFOU 0.6/1kV 1X95/10 P1/P8 Cold RFOU 0.6/1kV 1X120/10 P1/P8 Cold RFOU 0.6/1kV 1X150/10 P1/P8 Cold RFOU 0.6/1kV 1X185/10 P1/P8 Cold RFOU 0.6/1kV 1X240/16 P1/P8 Cold RFOU 0.6/1kV 1X300/16 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100006 7021528100013 7021528100020 7021528100037 7021528100044 7021528100051 7021528100068 7021528100075 7021528100082 7021528100099 7021528100105 - 810015 810018 810019 810020 810021 810022 810023 810024 810025 RFOU 0.6/1kV 2X1.5/4 P1/P8 Cold RFOU 0.6/1kV 3X1.5/4 P1/P8 Cold RFOU 0.6/1kV 4X1.5/6 P1/P8 Cold RFOU 0.6/1kV 5X1.5/6 P1/P8 Cold RFOU 0.6/1kV 7X1.5/6 P1/P8 Cold RFOU 0.6/1kV 12X1.5/10 P1/P8 Cold RFOU 0.6/1kV 19X1.5/10 P1/P8 Cold RFOU 0.6/1kV 27X1.5/10 P1/P8 Cold RFOU 0.6/1kV 37X1.5/16 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100150 7021528100181 7021528100198 7021528100204 7021528100211 7021528100228 7021528100235 7021528100242 7021528100259 - Subject to change without prior notice Page 129 of 212 New Part number Old Part number 810029 810032 810035 810036 810037 810038 810039 810040 810041 Tba Description RFOU 0.6/1kV 2X2.5/4 P1/P8 Cold RFOU 0.6/1kV 3X2.5/6 P1/P8 Cold RFOU 0.6/1kV 4X2.5/6 P1/P8 Cold RFOU 0.6/1kV 5X2.5/6 P1/P8 Cold RFOU 0.6/1kV 7X2.5/6 P1/P8 Cold RFOU 0.6/1kV 12X2.5/10 P1/P8 Cold RFOU 0.6/1kV 19X2.5/10 P1/P8 Cold RFOU 0.6/1kV 27X2.5/16 P1/P8 Cold RFOU 0.6/1kV 37X2.5/16 P1/P8 Cold RFOU 0.6/1kV 3G 2.5 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100297 7021528100327 7021528100358 7021528100365 7021528100372 7021528100389 7021528100396 7021528100402 7021528100419 - - 810045 810046 810047 810048 Tba Tba 810150 810151 RFOU 0.6/1kV 2X 4/6 P1/P8 Cold RFOU 0.6/1kV 3X 4/6 P1/P8 Cold RFOU 0.6/1kV 4X 4/6 P1/P8 Cold RFOU 0.6/1kV 5X 4/6 P1/P8 Cold RFOU 0.6/1kV 3G 4 P1/P8 Cold RFOU 0.6/1kV 4G 4 P1/P8 Cold RFOU 0.6/1kV 12X4/10 P1/P8 Cold RFOU 0.6/1kV 20X4/16 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100457 7021528100464 7021528100471 7021528100488 7021528101508 7021528101515 - 810051 810052 810053 Tba Tba 810056 RFOU 0.6/1kV 2X 6/6 P1/P8 Cold RFOU 0.6/1kV 3X 6/6 P1/P8 Cold RFOU 0.6/1kV 4X 6/6 P1/P8 Cold RFOU 0.6/1kV 3G 6 P1/P8 Cold RFOU 0.6/1kV 4G 6 P1/P8 Cold RFOU 0.6/1kV 5G 6 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100518 7021528100525 7021528100532 7021528100563 - 810057 810058 810059 Tba Tba RFOU 0.6/1kV 2X10/10 P1/P8 Cold RFOU 0.6/1kV 3X10/10 P1/P8 Cold RFOU 0.6/1kV 4X10/10 P1/P8 Cold RFOU 0.6/1kV 4G 10 P1/P8 Cold RFOU 0.6/1kV 5G 10 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK - 7021528100570 7021528100587 7021528100594 - - 810063 810064 810065 Tba Tba 810067 RFOU 0.6/1kV 2X16/16 P1/P8 Cold RFOU 0.6/1kV 3X16/16 P1/P8 Cold RFOU 0.6/1kV 4X16/16 P1/P8 Cold RFOU 0.6/1kV 3G 16 P1/P8 Cold RFOU 0.6/1kV 4G 16 P1/P8 Cold RFOU 0.6/1kV 5G 16 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK BLACK - 7021528100631 7021528100648 7021528100655 7021528100679 - 810069 810070 810071 Tba 810074 RFOU 0.6/1kV 2X25/16 P1/P8 Cold RFOU 0.6/1kV 3X25/16 P1/P8 Cold RFOU 0.6/1kV 4X25/16 P1/P8 Cold RFOU 0.6/1kV 4G 25 P1/P8 Cold RFOU 0.6/1kV 5G 25 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK - 7021528100693 7021528100709 7021528100716 7021528100747 - 810075 810076 810077 Tba 810079 RFOU 0.6/1kV 2X35/16 P1/P8 Cold RFOU 0.6/1kV 3X35/16 P1/P8 Cold RFOU 0.6/1kV 4X35/16 P1/P8 Cold RFOU 0.6/1kV 4G 35 P1/P8 Cold RFOU 0.6/1kV 5G 35 P1/P8 Cold BLACK BLACK BLACK BLACK BLACK - 7021528100754 7021528100761 7021528100778 7021528100792 - 810082 810083 Tba Tba RFOU 0.6/1kV 3X50/25 P1/P8 Cold RFOU 0.6/1kV 4X50/25 P1/P8 Cold RFOU 0.6/1kV 4G 50 P1/P8 Cold RFOU 0.6/1kV 5G 50 P1/P8 Cold BLACK BLACK BLACK BLACK - 7021528100822 7021528100839 - - 810087 810088 810089 RFOU 0.6/1kV 2X70/35 P1/P8 Cold RFOU 0.6/1kV 3X70/35 P1/P8 Cold RFOU 0.6/1kV 4X70/35 P1/P8 Cold RFOU 0.6/1kV 4G 70 P1/P8 Cold BLACK BLACK BLACK BLACK - 7021528100877 7021528100884 7021528100891 - - 810094 810095 810096 RFOU 0.6/1kV 2X95/50 P1/P8 Cold RFOU 0.6/1kV 3X95/50 P1/P8 Cold RFOU 0.6/1kV 4X95/50 P1/P8 Cold RFOU 0.6/1kV 4G 95 P1/P8 Cold BLACK BLACK BLACK BLACK - 7021528100945 7021528100952 7021528100969 - - 810100 810101 810105 RFOU 0.6/1kV 2X120/60 P1/P8 Cold RFOU 0.6/1kV 3X120/60 P1/P8 Cold RFOU 0.6/1kV 4X120/60 P1/P8 Cold BLACK BLACK BLACK - 7021528101003 7021528101010 7021528101058 - Subject to change without prior notice Sheath Colour Stock item EAN No. DNK Page 130 of 212 EL No. Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 1 1 1 1 1 1 1 1 1 1 1 16 25 35 50 70 95 120 150 185 240 300 2.5 4 6 6 10 10 10 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.529 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.118 0.111 0.108 0.105 0.100 0.097 0.095 0.093 0.092 0.090 0.088 0.142 0.134 0.129 0.126 0.120 0.117 0.114 0.112 0.110 0.108 0.105 96 127 157 196 242 293 339 389 444 522 601 2240 3500 4900 7000 9800 13300 16800 21000 25900 33600 42000 2 3 4 5 7 12 19 27 37 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 4 4 6 6 6 10 10 10 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0.132 0.132 0.132 0.132 0.132 0.132 0.132 0.132 0.132 20 16 16 13.5 12 10 8.5 7.5 7 210 210 210 210 210 210 210 210 210 2 3 4 5 7 12 19 27 37 3G 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 4 6 6 6 6 10 10 16 16 - STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.103 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.123 0.123 26 21 21 17.5 15.5 13 11 10 9 26 350 350 350 350 350 350 350 350 350 350 2 3 4 5 3G 4G 12 20 4 4 4 4 4 4 4 4 6 6 6 6 10 16 STCC STCC STCC STCC STCC STCC STCC STCC 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 5.99 5.99 5.99 5.99 5.99 5.99 5.99 5.99 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.096 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 34 28 28 23.5 34 28 17.5 14.5 560 560 560 560 560 560 560 560 2 3 4 3G 4G 5G 6 6 6 6 6 6 6 6 6 - STCC STCC STCC STCC STCC STCC 3.11 3.11 3.11 3.11 3.11 3.11 3.97 3.97 3.97 3.97 3.97 3.97 0.090 0.090 0.090 0.090 0.090 0.090 0.108 0.108 0.108 0.108 0.108 0.108 44 36 36 44 36 36 840 840 840 840 840 840 2 3 4 4G 5G 10 10 10 10 10 10 10 10 - STCC STCC STCC STCC STCC 1.84 1.84 1.84 1.84 1.84 2.35 2.35 2.35 2.35 2.35 0.084 0.084 0.084 0.084 0.084 0.101 0.101 0.101 0.101 0.101 61 50 50 50 50 1400 1400 1400 1400 1400 2 3 4 3G 4G 5G 16 16 16 16 16 16 16 16 16 - STCC STCC STCC STCC STCC STCC 1.16 1.16 1.16 1.16 1.16 1.16 1.48 1.48 1.48 1.48 1.48 1.48 0.080 0.080 0.080 0.080 0.080 0.080 0.096 0.096 0.096 0.096 0.096 0.096 80 67 67 80 67 67 2240 2240 2240 2240 2240 2240 2 3 4 4G 25 25 25 25 16 16 16 - STCC STCC STCC STCC 0.734 0.734 0.734 0.734 0.936 0.936 0.936 0.936 0.079 0.079 0.079 0.079 0.095 0.095 0.095 0.095 108 89 89 89 3500 3500 3500 3500 Subject to change without prior notice Page 131 of 212 Number of elements 5G Cross section core, mm² 25 Electrical Cross section braid, mm² - Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere STCC 0.734 0.936 0.079 0.095 89 3500 2 3 4 4G 5G 35 35 35 35 35 16 16 16 - STCC STCC STCC STCC STCC 0.529 0.529 0.529 0.529 0.529 0.675 0.675 0.675 0.675 0.675 0.076 0.076 0.076 0.076 0.076 0.092 0.092 0.092 0.092 0.092 133 110 110 110 110 4900 4900 4900 4900 4900 3 4 4G 5G 50 50 50 50 25 25 - STCC STCC STCC STCC 0.391 0.391 0.391 0.391 0.499 0.499 0.499 0.499 0.076 0.076 0.076 0.076 0.092 0.092 0.092 0.092 137 137 137 137 7000 7000 7000 7000 2 3 4 4G 70 70 70 70 35 35 35 - STCC STCC STCC STCC 0.27 0.27 0.27 0.27 0.344 0.344 0.344 0.344 0.074 0.074 0.074 0.074 0.088 0.088 0.088 0.088 206 169 169 169 9800 9800 9800 9800 2 3 4 4G 95 95 95 95 50 50 50 - STCC STCC STCC STCC 0.195 0.195 0.195 0.195 0.249 0.249 0.249 0.249 0.073 0.073 0.073 0.073 0.088 0.088 0.088 0.088 249 205 205 205 13300 13300 13300 13300 2 3 4 120 120 120 60 60 60 STCC STCC STCC 0.154 0.154 0.154 0.196 0.196 0.196 0.072 0.072 0.072 0.086 0.086 0.086 288 237 237 16800 16800 16800 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 132 of 212 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, large single core cables Flame retardant halogen-free power cable. Oil & Mud resistant. Cold bend / Cold impact resistant. Single core cable RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Arctic Grade Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EX- and safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 clause 8.9 & Annex E at -40°C / -35°C. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-352 Annex E (-40°C/-35°C) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Halogen Free - Low Smoke - Cold Bend / Cold Impact Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU 0.6/1kV P1/P8 1 x 400/25mm2 IEC 60092-353 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C DRAKA 01 = Draka Norsk Kabel, Black Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Page 133 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 - Range and dimensions Cross Number section of core, elements mm² Electrical Thickness Conductor Insulation Cross Inner Diameter, Thickness, section covering, mm mm braid, mm² mm Diameter inner covering, mm 1 25 34.5 ± 1.5 0.4 400 26.00 2.4 1.4 Thickness Diameter Outer Braid Sheath, Wire, mm mm 2.1 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 40.5 ± 2 5050 3970 Ordering information New Part number Old Part number 810011 Description Sheath Colour RFOU 0.6/1kV 1X400/25 P1/P8 Cold BLACK Stock item - EAN No. DNK EL No. 7021528100112 - Electrical values power cables Number of elements 1 Cross section core, mm² 400 Electrical Cross section braid, mm² 25 Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere STCC 0.0475 0.0606 0.087 0.104 690 dc / 670 ac 56000 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 134 of 212 ARCTIC GRADE power cable RFOU 0,6/1(1,2)kV, P1/P8, double braided Flame retardant halogen-free power cable. Oil & Mud resistant. Cold bend / Cold impact resistant. Double braided. RFOU 0,6/1(1,2)kV EPR/EPR/TCWB/EVA NEK TS 606 CodeP1/P8 Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power,control and lighting in both EXand safe areas, general purposes. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 clause 8.9 & Annex E at -40°C / -35°C. IEC 60092-353 - Design IEC 60228 class 2 - Conductor IEC 60092-360 - Insulation IEC 60092-360 - Sheath IEC 60332-1-2 - Flame Retardant IEC 60332-3-22 - Flame Retardant IEC 60754-1,2 - Halogen Free IEC 61034-1,2 - Low Smoke CSA 22.2 0.3-01 (-40°C/-35°C) - Cold Bend / / IEC 60092-352 Annex E (Cold Impact 40°C/-35°C) Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath R F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape + rubberized Polyamide tape O Two layers of tinned copper wire braid (double braid) PET tape + rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x150/70 mm2 IEC 60092-353 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel, Black Marking text Manufacturing unit Outer sheath colour Subject to change without prior notice Page 135 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 - Range and dimensions Cross Number section of core, elements mm² Electrical Thickness Conductor Insulation Cross Inner Diameter, Thickness, section covering, mm mm braid, mm² mm Diameter inner covering, mm Thickness Diameter Outer Braid Sheath, Wire, mm mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 3 4 150 150 75 75 15.9 15.9 1.8 1.8 1.6 2 46 ± 2 0.4 51.5 ± 2.5 0.5 2.6 2.8 54 ± 2.5 61 ± 3 7440 9450 4981 6444 3 4 185 185 95 95 17.70 17.7 2.0 2.0 1.6 2 50.5 ± 2.5 0.5 57 ± 2.5 0.5 2.7 3 59.5 ± 2.5 9200 67 ± 3 11390 6283 7837 3 240 120 20.15 2.2 1.8 57.5 ± 2.5 0.6 3 68 ± 3 8046 11760 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 810102 810103 RFOU 0.6/1kV 3X150/75 P1/P8 Cold RFOU 0.6/1kV 4X150/75 P1/P8 Cold BLACK BLACK - 7021528101027 7021528101034 - 810106 810107 RFOU 0.6/1kV 3X185/95 P1/P8 Cold RFOU 0.6/1kV 4X185/95 P1/P8 Cold BLACK BLACK - 7021528101065 7021528101072 - 810112 RFOU 0.6/1kV 3X240/120 P1/P8 Cold BLACK - 7021528101126 - Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 3 4 150 150 75 75 STCC STCC 0.126 0.126 0.161 0.161 0.072 0.072 0.087 0.087 272 272 21000 21000 3 4 185 185 95 95 STCC STCC 0.1 0.1 0.128 0.161 0.072 0.072 0.086 0.086 311 311 25900 25900 3 240 120 STCC 0.0762 0.0972 0.072 0.086 365 33600 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 136 of 212 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12 Fire resistant, flame retardant halogenfree power cable. Oil & Mud resistant. Cold bend / Cold impact resistant BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Arctic Grade Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C/-35°C. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-350 Annex E (-40°C/-35°C) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke - Cold Bend / Cold Impact Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BFOU 0.6/1kV P5/P12 3 x 50/25mm2 FLEX FLAME IEC 60092-353 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel Marking text Manufacturing unit Outer sheath colour Black *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 137 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 - Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm 1 16 4 5.15 1.0 1.1 10 ± 0.8 0.2 5.3 1.2 1 25 6 6.45 1.2 1.1 0.3 8.5 1.3 1 50 10 9.0 1.4 1.1 0.3 12.7 1.4 1 70 10 10.85 1.4 1.1 1 1 1 1 1 1 95 120 150 185 240 300 10 10 10 10 16 16 12.60 14.20 15.90 17.70 20.15 22.60 1.6 1.6 1.8 2.0 2.2 2.4 2 1.5 4 1.6 3 1.5 6 4 1.5 5 7 Diameter outer sheath, mm 13.5 ± 0.8 15.5 ± 0.8 19 ± 0.8 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 380 198 540 314 880 559 0.3 12.7 1.4 21 ± 1 1130 757 1.1 1.2 1.2 1.2 1.2 1.2 11.5 ± 0.8 15 ± 0.8 16.5 ± 0.8 19 ± 0.8 20.5 ± 1 23 ± 1 25 ± 1 28 ± 1 31 ± 1.5 0.3 0.3 0.3 0.3 0.3 0.3 15.3 15.3 17.8 17.8 20.4 22.9 1.5 1.6 1.7 1.7 1.8 1.9 23.5 ± 1 25.5 ± 1 28 ± 1 30 ± 1.5 33 ± 1.5 36 ± 1.5 1440 1740 2130 2510 3160 3880 996 1231 1535 1838 2365 2984 1.0 1.1 10 ± 0.8 0.2 5.3 1.2 290 80 1.6 1.0 1.1 0.3 8.5 1.3 360 125 6 1.6 1.0 1.1 0.3 10.2 1.3 1.5 1.5 6 6 1.6 1.6 1.0 1.0 1.1 1.1 0.3 0.3 10.2 11.9 12 1.5 10 1.6 1.0 1.2 0.3 19 27 37 1.5 1.5 1.5 10 16 16 1.6 1.6 1.6 1.0 1.0 1.0 1.2 1.2 1.4 2 2.5 6 2.0 1.0 1.1 3 2.5 6 2.0 1.0 1.1 4 2.5 6 2.0 1.0 1.1 7 2.5 6 2.0 1.0 1.1 12 19 2.5 2.5 10 16 2.0 2.0 1.0 1.0 27 2.5 16 2.0 37 2.5 25 3G 2.5 2 3 10.5 ± 0.8 11.5 ± 0.8 13 ± 0.8 13 ± 0.8 17.5 ± 0.8 20.5 ± 1 24.5 ± 1 27.5 ± 1 420 156 1.4 1.4 13.5 ± 0.8 14.5 ± 0.8 15.5 ± 0.8 17 ± 0.8 17 ± 0.8 490 540 170 214 15.3 1.6 22 ± 1 810 318 0.3 0.3 0.3 17.8 20.4 22.9 1.7 1.9 2 25 ± 1 29.5 ± 1 33 ± 1.5 1100 1450 1870 440 577 741 0.3 8.5 1.3 370 129 0.3 10.2 1.3 430 169 0.3 10.2 1.3 15 ± 0.8 15.5 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 23.5 ± 1 27.5 ± 1 32.5 ± 1.5 36.5 ± 1.5 15.5 ± 0.8 480 192 640 277 990 1380 450 636 1870 844 2500 1204 430 169 460 510 173 210 610 263 510 210 540 209 0.3 11.9 1.4 1.2 1.2 11 ± 0.8 11.5 ± 0.8 12.5 ± 0.8 14.5 ± 0.8 19 ± 0.8 22.5 ± 1 0.3 0.3 17.8 20.4 1.6 1.8 1.0 1.4 27 ± 1 0.3 22.9 2 2.0 1.0 1.4 0.4 36.2 2.2 - 2.0 1.0 1.1 0.3 10.2 1.3 4 4 6 6 2.55 2.55 1.0 1.0 1.1 1.1 12 ± 0.8 13 ± 0.8 0.3 0.3 10.2 10.2 1.3 1.3 4 4 6 2.55 1.0 1.1 14 ± 0.8 0.3 11.9 1.4 3G 4 - 2.55 1.0 1.1 13 ± 0.8 0.3 10.2 1.3 2 6 6 3.15 1.0 1.1 13.5 ± 0.8 0.3 10.2 1.4 Subject to change without prior notice 30.5 ± 1.5 11.5 ± 0.8 16 ± 0.8 17 ± 0.8 18.5 ± 0.8 16.5 ± 0.8 17.5 ± 0.8 Page 138 of 212 Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm 3 14 ± 0.8 0.3 11.9 1.4 0.3 11.9 1.4 0.3 13.6 1.5 0.3 0.3 0.3 0.3 11.9 11.9 13.6 15.3 0.5 6 6 3.15 1.0 1.1 4 6 6 3.15 1.0 1.1 5G 6 - 3.15 1.0 1.1 2 3 4 5G 10 10 10 10 10 10 10 - 4.05 4.05 4.05 4.05 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.2 2 16 16 5.15 1.0 1.1 3 16 16 5.15 1.0 1.1 4 16 16 5.15 1.0 2 3 4 25 25 25 16 16 16 6.45 6.45 6.45 2 3 4 35 35 35 16 16 16 5G 35 3 50 15.5 ± 0.8 17.5 ± 0.8 15 ± 0.8 16 ± 0.8 18 ± 0.8 20 ± 1 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 630 281 730 335 21.5 ± 1 890 406 1.4 1.5 1.5 1.6 19 ± 0.8 20.5 ± 1 22 ± 1 24.5 ± 1 690 810 980 1190 299 390 496 603 21.2 1.5 22.5 ± 1 990 500 18.5 ± 0.8 19.5 ± 0.8 0.4 22.6 1.5 23 ± 1 1170 660 1.2 17.5 ± 0.8 18.5 ± 0.8 21 ± 1 0.4 22.6 1.6 25.5 ± 1 1410 806 1.2 1.2 1.2 1.2 1.2 1.2 21 ± 1 22.5 ± 1 25 ± 1 0.4 0.3 0.3 22.6 20.4 20.4 1.6 1.7 1.8 26 ± 1 27.5 ± 1 30 ± 1.5 1370 1610 1960 685 894 1125 7.65 7.65 7.65 1.2 1.2 1.2 1.2 1.2 1.2 0.3 0.3 0.3 20.4 20.4 20.4 1.7 1.8 1.9 828 1142 1456 7.65 1.2 1.4 0.3 22.9 2 28.5 ± 1 30 ± 1.5 33 ± 1.5 36.5 ± 1.5 1650 2010 2470 - 23.5 ± 1 25.5 ± 1 28 ± 1 31.5 ± 1.5 2990 1795 25 9.0 1.4 1.2 29 ± 1 0.4 31.7 1.9 2720 1617 0.4 31.7 2 3360 2052 0.3 25.4 2 38 ± 1.5 3300 1991 0.4 36.2 2.2 42 ± 2 4090 2531 0.6 50.9 2 38 ± 1.5 3160 1783 4 50 25 9.0 1.4 1.4 4G 50 - 9.0 1.4 1.4 5G 50 - 9.0 1.4 1.4 2 70 35 10.85 1.4 1.6 3 70 35 10.85 1.4 1.4 4 5G 70 70 35 - 10.85 10.85 1.4 1.4 3 4 95 95 50 50 12.60 12.60 3 120 60 4 120 60 32.5 ± 1.5 32.5 ± 1.5 36 ± 1.5 34.5 ± 1.5 38.5 ± 1.5 0.5 49.5 2 39 ± 1.5 3750 2386 1.4 1.4 31.5 ± 1.5 33.5 ± 1.5 37 ± 1.5 41 ± 2 0.4 0.4 45.2 40.7 2.2 2.3 43 ± 2 47 ± 2 4580 5420 2977 3566 1.6 1.6 1.4 1.6 38 ± 1.5 42.5 ± 2 0.6 0.5 61.1 63.6 2.2 2.4 44.5 ± 2 49.5 ± 2 4900 6100 3168 4022 14.20 1.6 1.4 41.5 ± 2 0.6 71.3 2.4 6000 3976 14.20 1.6 1.6 46.5 ± 2 0.6 71.3 2.5 48.5 ± 2 53.5 ± 2.5 7430 5060 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 810200 810201 810203 810204 810205 810206 810207 810208 810209 810210 BFOU 0.6/1kV 1X16/4 P5/P12 Cold BFOU 0.6/1kV 1X25/6 P5/P12 Cold BFOU 0.6/1kV 1X50/10 P5/P12 Cold BFOU 0.6/1kV 1X70/10 P5/P12 Cold BFOU 0.6/1kV 1X95/10 P5/P12 Cold BFOU 0.6/1kV 1X120/10 P5/P12 Cold BFOU 0.6/1kV 1X150/10 P5/P12 Cold BFOU 0.6/1kV 1X185/10 P5/P12 Cold BFOU 0.6/1kV 1X240/16 P5/P12 Cold BFOU 0.6/1kV 1X300/16 P5/P12 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK - 7021528102000 7021528102017 7021528102031 7021528102048 7021528102055 7021528102062 7021528102079 7021528102086 7021528102093 7021528102109 - 810215 810218 810219 810220 BFOU 0.6/1kV 2X1.5/4 P5/P12 Cold BFOU 0.6/1kV 3X1.5/6 P5/P12 Cold BFOU 0.6/1kV 4X1.5/6 P5/P12 Cold BFOU 0.6/1kV 5X1.5/6 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102154 7021528102185 7021528102192 7021528102208 - Subject to change without prior notice Page 139 of 212 New Part number Old Part number 810221 810222 810223 810224 810225 Description Sheath Colour Stock item EAN No. DNK EL No. BFOU 0.6/1kV 7X1.5/6 P5/P12 Cold BFOU 0.6/1kV 12X1.5/10 P5/P12 Cold BFOU 0.6/1kV 19X1.5/10 P5/P12 Cold BFOU 0.6/1kV 27X1.5/16 P5/P12 Cold BFOU 0.6/1kV 37X1.5/16 P5/P12 Cold BLACK BLACK BLACK BLACK BLACK - 7021528102215 7021528102222 7021528102239 7021528102246 7021528102253 - BFOU 0.6/1kV 2X2.5/6 P5/P12 Cold BFOU 0.6/1kV 3X2.5/6 P5/P12 Cold BFOU 0.6/1kV 4X2.5/6 P5/P12 Cold BFOU 0.6/1kV 7X2.5/6 P5/P12 Cold BFOU 0.6/1kV 12X2.5/10 P5/P12 Cold BFOU 0.6/1kV 19X2.5/16 P5/P12 Cold BFOU 0.6/1kV 27X2.5/16 P5/P12 Cold BFOU 0.6/1kV 37X2.5/25 P5/P12 Cold BFOU 0.6/1kV 3G2.5 P5/P12 Cold BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Yes - 7021528102291 7021528102321 7021528102352 7021528102376 7021528102383 7021528102390 7021528102406 7021528102413 - - 810245 810246 810247 BFOU 0.6/1kV 2X4/6 P5/P12 Cold BFOU 0.6/1kV 3X4/6 P5/P12 Cold BFOU 0.6/1kV 4X4/6 P5/P12 Cold BFOU 0.6/1kV 3G 4 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102451 7021528102468 7021528102475 7021528102505 - 810251 810252 810253 Tba BFOU 0.6/1kV 2X6/6 P5/P12 Cold BFOU 0.6/1kV 3X6/6 P5/P12 Cold BFOU 0.6/1kV 4X6/6 P5/P12 Cold BFOU 0.6/1kV 5G 6 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102512 7021528102529 7021528102536 - - 810257 810258 810259 Tba BFOU 0.6/1kV 2X10/10 P5/P12 Cold BFOU 0.6/1kV 3X10/10 P5/P12 Cold BFOU 0.6/1kV 4X10/10 P5/P12 Cold BFOU 0.6/1kV 5G 10 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102574 7021528102581 7021528102598 - - 810263 810264 810265 BFOU 0.6/1kV 2X16/16 P5/P12 Cold BFOU 0.6/1kV 3X16/16 P5/P12 Cold BFOU 0.6/1kV 4X16/16 P5/P12 Cold BLACK BLACK BLACK - 7021528102635 7021528102642 7021528102659 - 810269 810270 810271 BFOU 0.6/1kV 2X25/16 P5/P12 Cold BFOU 0.6/1kV 3X25/16 P5/P12 Cold BFOU 0.6/1kV 4X25/16 P5/P12 Cold BLACK BLACK BLACK - 7021528102697 7021528102703 7021528102710 - 810275 810276 810277 Tba BFOU 0.6/1kV 2X35/16 P5/P12 Cold BFOU 0.6/1kV 3X35/16 P5/P12 Cold BFOU 0.6/1kV 4X35/16 P5/P12 Cold BFOU 0.6/1kV 5G 35 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102758 7021528102765 7021528102772 - - 810282 810283 Tba Tba BFOU 0.6/1kV 3X50/25 P5/P12 Cold BFOU 0.6/1kV 4X50/25 P5/P12 Cold BFOU 0.6/1kV 4G 50 P5/P12 Cold BFOU 0.6/1kV 5G 50 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102826 7021528102833 - - 810287 810288 810289 Tba BFOU 0.6/1kV 2X70/35 P5/P12 Cold BFOU 0.6/1kV 3X70/35 P5/P12 Cold BFOU 0.6/1kV 4X70/35 P5/P12 Cold BFOU 0.6/1kV 5G 70 P5/P12 Cold BLACK BLACK BLACK BLACK - 7021528102871 7021528102888 7021528102895 - - 810295 810296 BFOU 0.6/1kV 3X95/50 P5/P12 Cold BFOU 0.6/1kV 4X95/50 P5/P12 Cold BLACK BLACK - 7021528102956 7021528102963 - 810301 810304 BFOU 0.6/1kV 3X120/60 P5/P12 Cold BFOU 0.6/1kV 4X120/60 P5/P12 Cold BLACK BLACK - 7021528103014 7021528103045 - 810229 810232 810235 20115940 810238 810239 810240 810241 Tba 20110769 Subject to change without prior notice Page 140 of 212 Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 1 1 1 1 1 1 1 1 1 1 16 25 50 70 95 120 150 185 240 300 4 6 10 10 10 10 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC STCC 1.16 0.734 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 1.48 0.936 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.119 0.115 0.106 0.101 0.098 0.096 0.094 0.092 0.09 0.088 0.143 0.138 0.127 0.121 0.117 0.115 0.113 0.111 0.109 0.106 96 127 196 242 293 339 389 444 522 601 2240 3500 7000 9800 13300 16800 21000 25900 33600 42000 2 3 4 5 7 12 19 27 37 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 4 6 6 6 6 10 10 16 16 STCC STCC STCC STCC STCC STCC STCC STCC STCC 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 12.2 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.115 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.138 0.138 20 16 16 13.5 12 10 8.5 7.5 7 210 210 210 210 210 210 210 210 210 2 3 4 7 12 19 27 37 3G 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 6 6 6 6 10 16 16 25 - STCC STCC STCC STCC STCC STCC STCC STCC STCC 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 7.56 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 9.64 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.107 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 26 21 21 15.5 13 11 10 9 26 350 350 350 350 350 350 350 350 350 2 3 4 3G 4 4 4 4 6 6 6 - STCC STCC STCC STCC 4.7 4.7 4.7 4.7 5.99 5.99 5.99 5.99 0.100 0.100 0.1 0.100 0.120 0.120 0.120 0.120 34 28 28 34 560 560 560 560 2 3 4 5G 6 6 6 6 6 6 6 - STCC STCC STCC STCC 3.11 3.11 3.11 3.11 3.97 3.97 3.97 3.97 0.094 0.094 0.094 0.094 0.112 0.112 0.112 0.112 44 36 36 36 840 840 840 840 2 3 4 5G 10 10 10 10 10 10 10 - STCC STCC STCC STCC 1.84 1.84 1.84 1.84 2.35 2.35 2.35 2.35 0.088 0.088 0.088 0.088 0.105 0.105 0.105 0.105 61 50 50 50 1400 1400 1400 1400 2 3 4 16 16 16 16 16 16 STCC STCC STCC 1.16 1.16 1.16 1.48 1.48 1.48 0.082 0.082 0.082 0.099 0.099 0.099 80 67 67 2240 2240 2240 2 3 4 25 25 25 16 16 16 STCC STCC STCC 0.734 0.734 0.734 0.936 0.936 0.936 0.081 0.081 0.081 0.098 0.098 0.098 108 89 89 3500 3500 3500 2 3 4 5G 35 35 35 35 16 16 16 - STCC STCC STCC STCC 0.529 0.529 0.529 0.529 0.675 0.675 0.675 0.675 0.078 0.078 0.078 0.078 0.094 0.094 0.094 0.094 133 110 110 110 4900 4900 4900 4900 3 4 4G 5G 50 50 50 50 25 25 - STCC STCC STCC STCC 0.391 0.391 0.391 0.391 0.499 0.499 0.499 0.499 0.078 0.078 0.078 0.078 0.093 0.093 0.093 0.093 137 137 137 137 7000 7000 7000 7000 2 3 4 5G 70 70 70 70 35 35 35 - STCC STCC STCC STCC 0.27 0.27 0.27 0.27 0.344 0.344 0.344 0.344 0.075 0.077 0.077 0.077 0.092 0.092 0.092 0.092 206 169 169 169 9800 9800 9800 9800 Subject to change without prior notice Page 141 of 212 Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 3 4 95 95 50 50 STCC STCC 0.195 0.195 0.249 0.249 0.075 0.075 0.090 0.090 205 205 13300 13300 3 4 120 120 60 60 STCC STCC 0.154 0.154 0.196 0.196 0.073 0.073 0.088 0.088 237 237 16800 16800 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 142 of 212 ARCTIC GRADE Fire resistant power cable, BFOU 0,6/1(1,2)kV, P5/P12, double braided Fire resistant, flame retardant halogenfree power cable. Oil & Mud resistant. Cold bend / Cold impact resistant. Double braided. BFOU 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeP5/P12 Arctic Grade Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX (Zone 0, 1 & 2)- and safe areas, emergency and critical systems where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the OIL & MUD resistance requirement in NEK 606. Meets the cold bend / cold impact requirement in CSA 22.2 0.3-01 and IEC 60092-350 Clause 8.9 & Annex E at -40°C/-35°C. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 CSA 22.2 0.3-01 (-40°C/35°C) / IEC 60092-350 Annex E (-40°C/-35°C) - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke - Cold Bend / Cold Impact Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape O Two layers of tinned copper wire braid (double braid) Rubberized Polyamide tape U Flame retardant, halogen-free, mud and cold bend / cold impact resistant thermoset compound, SHF2 (IEC 60092-360) E.g. "meter" "year" DRAKA 01 BFOU 0.6/1kV P5/P12 3 x 50/25mm2 FLEX FLAME IEC 60092-353 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21 IEC 60332-3-22 ARCTIC GRADE Cold bend (-40 deg. C) / Cold impact (-35 deg. C) DRAKA 01 = Draka Norsk Kabel Marking text Manufacturing unit Outer sheath colour Black *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 143 of 212 Core identification power cables Single core - Black Two cores - Blue - Brown Three cores - Brown - Black - Grey Four cores - Blue - Brown - Black - Grey Five cores - Blue - Brown - Black - Grey - Black Seven cores and above - White with black numbers Two cores + earth (3G) - Yellow/green - Blue - Brown Three cores + earth (4G) - Yellow/green - Brown - Black - Grey Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core Core identification - to HD308S2 - and IEC 60445: Edition 5.0 2010-08 - Range and dimensions Electrical Cross Thickness Number Cross Conductor Insulation section Inner of section Diameter, Thickness, core, covering, elements braid, mm mm mm² mm mm² Diameter inner covering, mm Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm 3 150 75 15.90 1.8 1.4 46.5 ± 2 0.4 86 2.6 4 150 75 15.90 1.8 1.6 52 ± 2.5 0.5 99 3 185 95 17.70 2.0 1.6 185 95 17.7 2.0 1.8 51 ± 2.5 57.5 ± 2.5 0.5 4 0.4 3 240 120 19.1 2.2 2.0 56.0 ±2.0 0.7 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 7480 4992 2.8 54.5 ± 2.5 61 ± 3 9440 6451 127.2 2.8 60.5 ± 3 9310 6295 54.3 2.9 68±3 11590 7750 138.5 3.0 65.0 ± 3.0 11830 8042 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 810302 810309 BFOU 0.6/1kV 3X150/75 P5/P12 Cold BFOU 0.6/1kV 4X150/75 P5/P12 Cold BLACK BLACK - 7021528103021 7021528103090 - 810392 810391 BFOU 0.6/1kV 3X185/95 P5/P12 Cold BFOU 0.6/1kV 4X185/95 P5/P12 Cold BLACK BLACK - 7021528103922 7021528103915 - 810314 BFOU 0.6/1kV 3X240/120 P5/P12Cold BLACK - 7021528103144 - Electrical values power cables Number of elements Cross section core, mm² Electrical Cross section braid, mm² Conductor Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit type 2 resistance at resistance at 50Hz, 60Hz, IEC 60092rating 1 20°C, Ohm/km 90°C, Ohm/km Ohm/km Ohm/km 352 Table second, B.4, Ampere Ampere 3 4 150 150 75 75 STCC STCC 0.126 0.126 0.161 0.161 0.073 0.073 0.088 0.088 272 272 21000 21000 3 4 185 185 95 95 STCC STCC 0.1 0.1 0.128 0.128 0.073 0.073 0.088 0.088 311 311 25900 25900 3 240 120 STCC 0.0762 0.0972 0.074 0.089 365 33600 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -40°C Page 144 of 212 eXtended Fire Resistant, instrumentation cable BFOU-XFR(i) 150/250(300)V eXtended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes). IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1,-2 EN 50200:2006 Annex E IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU-XFR(I) 250V 4PAIR 1.5mm2 FLEX - FLAME IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 145 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm 1 2 0.75 1.1 1 1.1 9.5 ± 0.5 0.2 5.3 1.1 1 2 0.75 1.1 1 1.1 9.5 ± 0.5 0.2 5.3 1.1 2 2 0.75 1.1 1 1.1 0.3 11.9 1.3 2 2 0.75 1.1 1 1.1 4 4 8 8 2 2 2 2 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1 1 1 1 12 2 0.75 1.1 12 2 0.75 16 2 16 24 24 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 265 69 265 69 18 ± 0.8 470 150 12.5 ± 0.8 12.5 ± 0.8 0.3 11.9 1.3 18 ± 0.8 470 150 1.1 1.1 1.1 1.1 14.5 ± 0.8 14.5 ± 0.8 17 ± 0.8 17 ± 0.8 23.5 ± 1 23.5 ± 1 0.3 0.3 0.3 0.3 13.6 13.6 17.8 17.8 1.4 1.4 1.6 1.6 650 650 1060 1060 200 200 308 308 1 1.4 28 ± 1 0.3 20.4 1.7 1450 400 1.1 1 1.4 28 ± 1 0.3 20.4 1.7 1450 400 0.75 1.1 1 1.9 0.3 22.9 1.8 1940 491 2 0.75 1.1 1 1.9 2 2 0.75 0.75 1.1 1.1 1 1 2.3 2.3 1 3 0.75 1.1 1 1.1 1 3 0.75 1.1 1 1.1 2 3 0.75 1.1 1 2 3 0.75 1.1 21 ± 1 21 ± 1 27.5 ± 1 27.5 ± 1 32.5 ± 1.5 32.5 ± 1.5 37.5 ± 1.5 37.5 ± 1.5 46.5 ± 2 46.5 ± 2 13.5 ± 0.8 13.5 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 4 3 0.75 4 3 8 8 12 12 16 16 24 24 32.5 ± 1.5 32.5 ± 1.5 40.5 ± 2 40.5 ± 2 10.5 ± 0.8 10.5 ± 0.8 0.3 22.9 1.8 0.4 0.4 40.7 40.7 2.1 2.1 0.2 5.3 1.1 0.2 5.3 1.1 1.1 16 ± 0.8 0.3 11.9 1.4 1 1.1 16 ± 0.8 0.3 11.9 1.4 1.1 1 1.1 0.3 15.3 1.4 0.75 1.1 1 1.1 0.3 15.3 3 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1 1 1 1 1 1 1 1 1.1 1.1 1.4 1.4 2.1 2.1 2.5 2.5 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 1 2 1.5 1.6 1 1.1 1 2 1.5 1.6 1 1.1 2 2 4 4 2 2 2 2 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 1.1 1.1 1.1 1.1 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 31 ± 1.5 31 ± 1.5 36 ± 1.5 36 ± 1.5 45 ± 2 45 ± 2 10.5 ± 0.8 10.5 ± 0.8 16 ± 0.8 16 ± 0.8 19 ± 0.8 19 ± 0.8 8 2 1.5 1.6 1 1.1 8 2 1.5 1.6 1 1.1 12 2 1.5 1.6 1 1.4 12 2 1.5 1.6 1 1.4 16 16 2 2 1.5 1.5 1.6 1.6 1 1 24 2 1.5 1.6 24 2 1.5 1.6 Subject to change without prior notice 1940 491 2950 2950 799 799 290 75 290 75 540 163 540 163 22.5 ± 1 780 243 1.4 22.5 ± 1 780 243 20.4 20.4 22.9 22.9 25.4 25.4 45.2 45.2 1.7 1.7 1.8 1.8 1.9 1.9 2.2 2.2 1320 1320 1830 1830 2480 2480 3730 3730 386 386 503 503 621 621 1000 1000 0.2 5.3 1.1 310 86 0.2 5.3 1.1 310 86 0.3 0.3 0.3 0.3 13.6 13.6 15.3 15.3 1.4 1.4 1.5 1.5 580 580 820 820 201 201 286 286 26 ± 1 0.3 20.4 1.7 1360 472 26 ± 1 0.3 20.4 1.7 1360 472 0.3 22.9 1.9 29.5 ± 1 29.5 ± 1 36 ± 1.5 36 ± 1.5 41.5 ± 2 41.5 ± 2 51 ± 2.5 51 ± 2.5 13.5 ± 0.8 13.5 ± 0.8 20 ± 1 20 ± 1 23 ± 1 23 ± 1 30.5 ± 1.5 30.5 ± 1.5 36.5 ± 1.5 36.5 ± 1.5 42.5 ± 2 42.5 ± 2 51.5 ± 2.5 51.5 ± 1910 633 0.3 22.9 1.9 2.1 2.1 31.5 ± 1.5 31.5 ± 1.5 37 ± 1.5 37 ± 1.5 0.4 0.4 36.2 36.2 2 2 1 2.3 45.5 ± 2 0.4 45.2 2.3 1 2.3 45.5 ± 2 0.4 45.2 2.3 1910 633 2700 2700 899 899 3810 1259 3810 1259 Page 146 of 212 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm Diameter outer sheath, mm 2.5 14.5 ± 0.8 14.5 ± 0.8 Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 360 108 360 108 680 230 1 3 1.5 1.6 1 1.1 1 3 1.5 1.6 1 1.1 2 3 1.5 1.6 1 1.1 2 3 1.5 1.6 1 1.1 4 4 3 3 1.5 1.5 1.6 1.6 1 1 1.1 1.1 11.5 ± 0.8 11.5 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 21 ± 1 21 ± 1 8 3 1.5 1.6 1 1.1 28 ± 1 0.3 20.4 1.8 8 3 1.5 1.6 1 1.1 28 ± 1 0.3 20.4 1.8 0.3 25.4 2 40.5 ± 2 2470 828 0.3 25.4 2 40.5 ± 2 2470 828 0.4 0.4 0.5 0.5 40.7 40.7 63.6 63.6 2.2 2.2 2.6 2.6 3480 3480 5170 5170 1171 1171 1781 1781 0.2 6 1.2 360 114 0.2 6 1.2 47 ± 2 47 ± 2 58 ± 2.5 58 ± 2.5 14.5 ± 0.8 14.5 ± 0.8 360 114 0.3 13.6 1.5 21.5 ± 1 660 242 0.3 13.6 1.5 21.5 ± 1 660 242 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 15.3 15.3 20.4 20.4 25.4 25.4 40.7 40.7 1.6 1.6 1.8 1.8 2 2 2.2 2.2 25 ± 1 25 ± 1 33 ± 1.5 33 ± 1.5 41.5 ± 2 41.5 ± 2 46.5 ± 2 46.5 ± 2 15.5 ± 0.8 15.5 ± 0.8 23 ± 1 23 ± 1 27 ± 1 27 ± 1 35.5 ± 1.5 35.5 ± 1.5 46.5 ± 2 46.5 ± 2 970 970 1620 1620 2570 2570 3330 3330 367 367 634 634 901 901 1268 1268 410 137 410 137 790 790 1200 1200 305 305 484 484 2120 844 2120 844 3490 3490 1328 1328 0.2 6 1.2 0.2 6 1.2 0.3 13.6 1.5 22 ± 1 0.3 13.6 1.5 22 ± 1 680 230 0.3 0.3 17.8 17.8 1.6 1.6 25 ± 1 25 ± 1 32.5 ± 1.5 32.5 ± 1.5 1030 1030 368 368 1680 586 1680 586 12 3 1.5 1.6 1 1.6 12 3 1.5 1.6 1 1.6 16 16 24 24 3 3 3 3 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 2.3 2.3 2.7 2.7 1 2 2.5 2 1 1.1 1 2 2.5 2 1 1.1 2 2 2.5 2 1 1.1 2 2 2.5 2 1 1.1 4 4 8 8 12 12 16 16 2 2 2 2 2 2 2 2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1.1 1.1 1.1 1.1 2.3 2.3 2.3 2.3 35.5 ± 1.5 35.5 ± 1.5 41 ± 2 41 ± 2 51 ± 2.5 51 ± 2.5 11.5 ± 0.8 11.5 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 20.5 ± 1 20.5 ± 1 28.5 ± 1 28.5 ± 1 36 ± 1.5 36 ± 1.5 40.5 ± 2 40.5 ± 2 1 3 2.5 2 1 1.1 12 ± 0.8 0.2 6 1.2 1 3 2.5 2 1 1.1 12 ± 0.8 0.2 6 1.2 2 2 4 4 3 3 3 3 2.5 2.5 2.5 2.5 2 2 2 2 1 1 1 1 1.1 1.1 1.1 1.1 0.3 0.3 0.3 0.3 15.3 15.3 17.8 17.8 1.5 1.5 1.6 1.6 8 3 2.5 2 1 1.3 0.3 22.9 2 8 3 2.5 2 1 1.3 0.3 22.9 2 12 12 3 3 2.5 2.5 2 2 1 1 2.6 2.6 19 ± 0.8 19 ± 0.8 22.5 ± 1 22.5 ± 1 30.5 ± 1.5 30.5 ± 1.5 40.5 ± 2 40.5 ± 2 0.4 0.4 40.7 40.7 2.2 2.2 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² 65 65 0,94 0,94 26,3 26,3 17,9 17,9 Shielded pair 1,5 mm² Shielded triple 1,5 mm² 80 80 0,84 0,84 12,9 12,9 32,6 32,6 Shielded pair 2,5 mm² Shielded triple 2,5 mm² 100 100 0,77 0,77 8,02 8,02 48 48 Subject to change without prior notice Page 147 of 212 Ordering information New Part number Old Part number 822300 822301 822306 822307 822318 822319 822330 822331 822336 822337 822342 822343 822348 822349 822360 822361 822366 822367 822378 822379 822390 822391 822396 822397 822402 822403 822408 822409 822700 822701 822706 822707 822718 822719 822730 822731 822736 822737 822742 822743 822748 822749 822760 822761 822766 822767 822778 822779 822790 822791 822796 822797 822802 822803 822808 822809 828900 828901 828906 828907 828918 Description BFOU-XFR(I) 1PAIR 0.75mm² BFOU-XFR(I) 1PAIR 0.75mm² BFOU-XFR(I) 2PAIR 0.75mm² BFOU-XFR(I) 2PAIR 0.75mm² BFOU-XFR(I) 4PAIR 0.75mm² BFOU-XFR(I) 4PAIR 0.75mm² BFOU-XFR(I) 8PAIR 0.75mm² BFOU-XFR(I) 8PAIR 0.75mm² BFOU-XFR(I) 12PAIR 0.75mm² BFOU-XFR(I) 12PAIR 0.75mm² BFOU-XFR(I) 16PAIR 0.75mm² BFOU-XFR(I) 16PAIR 0.75mm² BFOU-XFR(I) 24PAIR 0.75mm² BFOU-XFR(I) 24PAIR 0.75mm² BFOU-XFR(I) 1TRIP 0.75mm² BFOU-XFR(I) 1TRIP 0.75mm² BFOU-XFR(I) 2TRIP 0.75mm² BFOU-XFR(I) 2TRIP 0.75mm² BFOU-XFR(I) 4TRIP 0.75mm² BFOU-XFR(I) 4TRIP 0.75mm² BFOU-XFR(I) 8TRIP 0.75mm² BFOU-XFR(I) 8TRIP 0.75mm² BFOU-XFR(I) 12TRIP 0.75mm² BFOU-XFR(I) 12TRIP 0.75mm² BFOU-XFR(I) 16TRIP 0.75mm² BFOU-XFR(I) 16TRIP 0.75mm² BFOU-XFR(I) 24TRIP 0.75mm² BFOU-XFR(I) 24TRIP 0.75mm² BFOU-XFR(I) 1PAIR 1.5mm² BFOU-XFR(I) 1PAIR 1.5mm² BFOU-XFR(I) 2PAIR 1.5mm² BFOU-XFR(I) 2PAIR 1.5mm² BFOU-XFR(I) 4PAIR 1.5mm² BFOU-XFR(I) 4PAIR 1.5mm² BFOU-XFR(I) 8PAIR 1.5mm² BFOU-XFR(I) 8PAIR 1.5mm² BFOU-XFR(I) 12PAIR 1.5mm² BFOU-XFR(I) 12PAIR 1.5mm² BFOU-XFR(I) 16PAIR 1.5mm² BFOU-XFR(I) 16PAIR 1.5mm² BFOU-XFR(I) 24PAIR 1.5mm² BFOU-XFR(I) 24PAIR 1.5mm² BFOU-XFR(I) 1TRIP 1.5mm² BFOU-XFR(I) 1TRIP 1.5mm² BFOU-XFR(I) 2TRIP 1.5mm² BFOU-XFR(I) 2TRIP 1.5mm² BFOU-XFR(I) 4TRIP 1.5mm² BFOU-XFR(I) 4TRIP 1.5mm² BFOU-XFR(I) 8TRIP 1.5mm² BFOU-XFR(I) 8TRIP 1.5mm² BFOU-XFR(I) 12TRIP 1.5mm² BFOU-XFR(I) 12TRIP 1.5mm² BFOU-XFR(I) 16TRIP 1.5mm² BFOU-XFR(I) 16TRIP 1.5mm² BFOU-XFR(I) 24TRIP 1.5mm² BFOU-XFR(I) 24TRIP 1.5mm² BFOU-XFR(I) 1PAIR 2.5mm² BFOU-XFR(I) 1PAIR 2.5mm² BFOU-XFR(I) 2PAIR 2.5mm² BFOU-XFR(I) 2PAIR 2.5mm² BFOU-XFR(I) 4PAIR 2.5mm² Subject to change without prior notice Sheath Colour GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY Stock item - EAN No. DNK 7021528223002 7021528223019 7021528223064 7021528223071 7021528223187 7021528223194 7021528223309 7021528223316 7021528223361 7021528223378 7021528223422 7021528223439 7021528223484 7021528223491 7021528223606 7021528223613 7021528223668 7021528223675 7021528223781 7021528223798 7021528223903 7021528223910 7021528223965 7021528223972 7021528224023 7021528224030 7021528224085 7021528224092 7021528227000 7021528227017 7021528227062 7021528227079 7021528227185 7021528227192 7021528227307 7021528227314 7021528227369 7021528227376 7021528227420 7021528227437 7021528227482 7021528227499 7021528227604 7021528227611 7021528227666 7021528227673 7021528227789 7021528227796 7021528227901 7021528227918 7021528227963 7021528227970 7021528228021 7021528228038 7021528228083 7021528228090 7021528289008 7021528289015 7021528289060 7021528289077 7021528289183 Page 148 of 212 EL No. - New Part number Old Part number 828919 828930 828931 828936 828937 828942 828943 828960 828961 828966 828967 828978 828979 828990 828991 828996 828997 Description BFOU-XFR(I) 4PAIR 2.5mm² BFOU-XFR(I) 8PAIR 2.5mm² BFOU-XFR(I) 8PAIR 2.5mm² BFOU-XFR(I) 12PAIR 2.5mm² BFOU-XFR(I) 12PAIR 2.5mm² BFOU-XFR(I) 16PAIR 2.5mm² BFOU-XFR(I) 16PAIR 2.5mm² BFOU-XFR(I) 1TRIP 2.5mm² BFOU-XFR(I) 1TRIP 2.5mm² BFOU-XFR(I) 2TRIP 2.5mm² BFOU-XFR(I) 2TRIP 2.5mm² BFOU-XFR(I) 4TRIP 2.5mm² BFOU-XFR(I) 4TRIP 2.5mm² BFOU-XFR(I) 8TRIP 2.5mm² BFOU-XFR(I) 8TRIP 2.5mm² BFOU-XFR(I) 12TRIP 2.5mm² BFOU-XFR(I) 12TRIP 2.5mm² Sheath Colour BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Stock item - EAN No. DNK 7021528289190 7021528289305 7021528289312 7021528289367 7021528289374 7021528289428 7021528289435 7021528289602 7021528289619 7021528289664 7021528289671 7021528289787 7021528289794 7021528289909 7021528289916 7021528289961 7021528289978 EL No. - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 149 of 212 eXtended Fire Resistant, instrumentation cable BFOU-XFR(c) 150/250(300)V eXtended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(c) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes). IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2 EN 50200:2006 Annex E IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFOU-XFR(C) 250V 4PAIR 1.5mm2 FLEX - FLAME IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 150 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² Thickness Outer Sheath, mm 2 2 0.75 1.1 1 1.1 14 ± 0.8 0.3 10.2 1.3 2 2 0.75 1.1 1 1.1 14 ± 0.8 0.3 10.2 1.3 4 2 0.75 1.1 1 1.1 0.3 11.9 1.3 4 2 0.75 1.1 1 1.1 8 8 2 2 0.75 0.75 1.1 1.1 1 1 12 2 0.75 1.1 12 2 0.75 16 2 16 2 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 440 130 440 130 20 ± 1 580 172 17.5 ± 0.8 17.5 ± 0.8 0.3 11.9 1.3 20 ± 1 580 172 1.1 1.1 16.5 ± 0.8 16.5 ± 0.8 22 ± 1 22 ± 1 0.3 0.3 17.8 17.8 1.5 1.5 960 960 282 282 1 1.4 26.5 ± 1 0.3 20.4 1.6 1290 358 1.1 1 1.4 26.5 ± 1 0.3 20.4 1.6 1290 358 0.75 1.1 1 1.9 29.5 ± 1 0.3 22.9 1.7 1690 435 0.75 1.1 1 1.9 29.5 ± 1 0.3 22.9 1.7 26.5 ± 1 26.5 ± 1 30.5 ± 1.5 30.5 ± 1.5 34.5 ± 1.5 34.5 ± 1.5 1690 435 0.4 36.2 2 42.5 ± 2 2530 668 0.4 36.2 2 42.5 ± 2 2530 668 530 159 530 159 750 231 36.5 ± 1.5 36.5 ± 1.5 24 2 0.75 1.1 1 2.3 24 2 0.75 1.1 1 2.3 2 3 0.75 1.1 1 1.1 16 ± 0.8 0.3 11.9 1.3 2 3 0.75 1.1 1 1.1 16 ± 0.8 0.3 11.9 1.3 4 3 0.75 1.1 1 1.1 0.3 15.3 1.4 4 3 0.75 1.1 1 1.1 8 8 3 3 0.75 0.75 1.1 1.1 1 1 12 3 0.75 1.1 12 3 0.75 16 16 24 24 3 3 3 3 2 19.5 ± 0.8 19.5 ± 0.8 0.3 15.3 1.4 22.5 ± 1 750 231 1.1 1.1 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 0.3 0.3 17.8 17.8 1.6 1.6 1210 1210 334 334 1 1.4 30 ± 1.5 0.3 22.9 1.7 1670 461 1.1 1 1.4 30 ± 1.5 0.3 22.9 1.7 1670 461 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1 1 1 1 2.1 2.1 2.5 2.5 0.3 0.3 0.4 0.4 25.4 25.4 40.7 40.7 1.8 1.8 2.1 2.1 2240 2240 3340 3340 564 564 868 868 2 1.5 1.6 1 1.1 0.3 11.9 1.4 540 179 2 2 1.5 1.6 1 1.1 0.3 11.9 1.4 540 179 4 2 1.5 1.6 1 1.1 0.3 15.3 1.4 22 ± 1 750 268 4 2 1.5 1.6 1 1.1 0.3 15.3 1.4 22 ± 1 750 268 8 8 2 2 1.5 1.5 1.6 1.6 1 1 1.1 1.1 34 ± 1.5 34 ± 1.5 42.5 ± 2 42.5 ± 2 15.5 ± 0.8 15.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 29 ± 1 29 ± 1 34.5 ± 1.5 34.5 ± 1.5 39 ± 1.5 39 ± 1.5 48 ± 2 48 ± 2 19.5 ± 0.8 19.5 ± 0.8 0.3 0.3 17.8 17.8 1.7 1.7 1210 1210 405 405 12 2 1.5 1.6 1 1.4 29.5 ± 1 0.3 22.9 1.8 1680 567 12 2 1.5 1.6 1 1.4 29.5 ± 1 0.3 22.9 1.8 1680 567 16 16 24 24 2 2 2 2 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 1.9 1.9 2.3 2.3 0.3 0.3 0.4 0.4 25.4 25.4 40.7 40.7 1.9 1.9 2.2 2.2 2180 2180 3260 3260 704 704 1077 1077 2 3 1.5 1.6 1 1.1 0.3 13.6 1.4 21.5 ± 1 660 224 2 3 1.5 1.6 1 1.1 4 3 1.5 1.6 1 1.1 33 ± 1.5 33 ± 1.5 41 ± 2 41 ± 2 17.5 ± 0.8 17.5 ± 0.8 21 ± 1 29.5 ± 1 29.5 ± 1 34.5 ± 1.5 34.5 ± 1.5 38 ± 1.5 38 ± 1.5 47 ± 2 47 ± 2 Subject to change without prior notice 22.5 ± 1 0.3 13.6 1.4 21.5 ± 1 660 224 0.3 17.8 1.5 25 ± 1 960 350 Page 151 of 212 Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 1.1 Mechanical Diameter Diameter crossinner Braid section of covering, Wire, mm the braid, mm mm² 21 ± 1 0.3 17.8 1.5 960 350 1 1.1 28 ± 1 0.3 20.4 1.8 1580 543 1.6 1 1.1 28 ± 1 0.3 20.4 1.8 1580 543 1.5 1.6 1 1.4 34 ± 1.5 0.3 25.4 1.9 2190 762 1.5 1.6 1 1.4 34 ± 1.5 0.3 25.4 1.9 25 ± 1 32.5 ± 1.5 32.5 ± 1.5 38.5 ± 1.5 38.5 ± 1.5 2190 762 0.4 40.7 2.1 44.5 ± 2 3150 1080 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 4 3 1.5 1.6 1 8 3 1.5 1.6 8 3 1.5 12 3 12 3 38.5 ± 1.5 38.5 ± 1.5 47.5 ± 2 47.5 ± 2 17 ± 0.8 17 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 0.4 40.7 2.1 44.5 ± 2 3150 1080 0.4 0.4 0.3 0.3 45.2 45.2 13.6 13.6 2.4 2.4 1.4 1.4 54 ± 2.5 54 ± 2.5 20.5 ± 1 20.5 ± 1 4450 4450 620 620 1462 1462 234 234 0.3 15.3 1.5 24 ± 1 880 343 0.3 15.3 1.5 24 ± 1 880 343 1480 577 1480 577 2240 811 2240 811 16 3 1.5 1.6 1 2.3 16 3 1.5 1.6 1 2.3 24 24 2 2 3 3 2 2 1.5 1.5 2.5 2.5 1.6 1.6 2 2 1 1 1 1 2.7 2.7 1.1 1.1 4 2 2.5 2 1 1.1 4 2 2.5 2 1 1.1 8 2 2.5 2 1 1.1 27 ± 1 0.3 20.4 1.8 8 2 2.5 2 1 1.1 27 ± 1 0.3 20.4 1.8 12 2 2.5 2 1 2.1 0.3 25.4 1.9 12 2 2.5 2 1 2.1 0.3 25.4 1.9 16 2 2.5 2 1 2.3 0.4 36.2 2.1 42.5 ± 2 2900 1101 16 2 2.5 2 1 2.3 0.4 36.2 2.1 42.5 ± 2 2900 1101 24 2 2.5 2 1 2.7 45 ± 2 0.4 45.2 2.4 4150 1558 24 2 2.5 2 1 2.7 45 ± 2 0.4 45.2 2.4 4150 1558 2 2 4 4 8 8 12 12 16 16 3 3 3 3 3 3 3 3 3 3 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.1 1.1 2.6 2.6 2.6 2.6 19 ± 0.8 19 ± 0.8 22.5 ± 1 22.5 ± 1 30 ± 1.5 30 ± 1.5 39 ± 1.5 39 ± 1.5 42.5 ± 2 42.5 ± 2 0.3 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.4 15.3 15.3 17.8 17.8 22.9 22.9 40.7 40.7 40.7 40.7 1.5 1.5 1.6 1.6 1.9 1.9 2.1 2.1 2.3 2.3 780 780 1160 1160 1950 1950 3230 3230 3950 3950 297 297 461 461 788 788 1241 1241 1518 1518 33.5 ± 1.5 33.5 ± 1.5 36.5 ± 1.5 36.5 ± 1.5 31.5 ± 1.5 31.5 ± 1.5 38.5 ± 1.5 38.5 ± 1.5 51.5 ± 2.5 51.5 ± 2.5 23 ± 1 23 ± 1 27 ± 1 27 ± 1 35 ± 1.5 35 ± 1.5 44.5 ± 2 44.5 ± 2 48.5 ± 2 48.5 ± 2 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² 55 0,94 26,3 17,9 Unshielded triple 0,75 mm² 55 0,94 26,3 17,9 Unshielded pair 1,5 mm² 65 0,89 12,9 32,6 Unshielded triple 1,5 mm² 65 0,89 12,9 32,6 Unshielded pair 2,5 mm² 75 0,77 8,02 48 Unshielded triple 2,5 mm² 75 0,77 8,02 48 Subject to change without prior notice Page 152 of 212 Ordering information New Part number Old Part number 822906 822907 822918 822919 822930 822931 822936 822937 822942 822943 822948 822949 822966 822967 822978 822979 822990 822991 822996 822997 823002 823003 823008 823009 823306 823307 823318 823319 823330 823331 823336 823337 823342 823343 823348 823349 823366 823367 823378 823379 823390 823391 823396 823397 823402 823403 823408 823409 828506 828507 828518 828519 828530 828531 828536 828537 828542 828543 828548 828549 828566 828567 Description BFOU-XFR(C) 2PAIR 0.75mm² BFOU-XFR(C) 2PAIR 0.75mm² BFOU-XFR(C) 4PAIR 0.75mm² BFOU-XFR(C) 4PAIR 0.75mm² BFOU-XFR(C) 8PAIR 0.75mm² BFOU-XFR(C) 8PAIR 0.75mm² BFOU-XFR(C) 12PAIR 0.75mm² BFOU-XFR(C) 12PAIR 0.75mm² BFOU-XFR(C) 16PAIR 0.75mm² BFOU-XFR(C) 16PAIR 0.75mm² BFOU-XFR(C) 24PAIR 0.75mm² BFOU-XFR(C) 24PAIR 0.75mm² BFOU-XFR(C) 2TRIP 0.75mm² BFOU-XFR(C) 2TRIP 0.75mm² BFOU-XFR(C) 4TRIP 0.75mm² BFOU-XFR(C) 4TRIP 0.75mm² BFOU-XFR(C) 8TRIP 0.75mm² BFOU-XFR(C) 8TRIP 0.75mm² BFOU-XFR(C) 12TRIP 0.75mm² BFOU-XFR(C) 12TRIP 0.75mm² BFOU-XFR(C) 16TRIP 0.75mm² BFOU-XFR(C) 16TRIP 0.75mm² BFOU-XFR(C) 24TRIP 0.75mm² BFOU-XFR(C) 24TRIP 0.75mm² BFOU-XFR(C) 2PAIR 1.5mm² BFOU-XFR(C) 2PAIR 1.5mm² BFOU-XFR(C) 4PAIR 1.5mm² BFOU-XFR(C) 4PAIR 1.5mm² BFOU-XFR(C) 8PAIR 1.5mm² BFOU-XFR(C) 8PAIR 1.5mm² BFOU-XFR(C) 12PAIR 1.5mm² BFOU-XFR(C) 12PAIR 1.5mm² BFOU-XFR(C) 16PAIR 1.5mm² BFOU-XFR(C) 16PAIR 1.5mm² BFOU-XFR(C) 24PAIR 1.5mm² BFOU-XFR(C) 24PAIR 1.5mm² BFOU-XFR(C) 2TRIP 1.5mm² BFOU-XFR(C) 2TRIP 1.5mm² BFOU-XFR(C) 4TRIP 1.5mm² BFOU-XFR(C) 4TRIP 1.5mm² BFOU-XFR(C) 8TRIP 1.5mm² BFOU-XFR(C) 8TRIP 1.5mm² BFOU-XFR(C) 12TRIP 1.5mm² BFOU-XFR(C) 12TRIP 1.5mm² BFOU-XFR(C) 16TRIP 1.5mm² BFOU-XFR(C) 16TRIP 1.5mm² BFOU-XFR(C) 24TRIP 1.5mm² BFOU-XFR(C) 24TRIP 1.5mm² BFOU-XFR(C) 2PAIR 2.5mm² BFOU-XFR(C) 2PAIR 2.5mm² BFOU-XFR(C) 4PAIR 2.5mm² BFOU-XFR(C) 4PAIR 2.5mm² BFOU-XFR(C) 8PAIR 2.5mm² BFOU-XFR(C) 8PAIR 2.5mm² BFOU-XFR(C) 12PAIR 2.5mm² BFOU-XFR(C) 12PAIR 2.5mm² BFOU-XFR(C) 16PAIR 2.5mm² BFOU-XFR(C) 16PAIR 2.5mm² BFOU-XFR(C) 24PAIR 2.5mm² BFOU-XFR(C) 24PAIR 2.5mm² BFOU-XFR(C) 2TRIP 2.5mm² BFOU-XFR(C) 2TRIP 2.5mm² Subject to change without prior notice Sheath Colour GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE Stock item - EAN No. DNK 7021528229066 7021528229073 7021528229189 7021528229196 7021528229301 7021528229318 7021528229363 7021528229370 7021528229424 7021528229431 7021528229486 7021528229493 7021528229660 7021528229677 7021528229783 7021528229790 7021528229905 7021528229912 7021528229967 7021528229974 7021528230024 7021528230031 7021528230086 7021528230093 7021528233063 7021528233070 7021528233186 7021528233193 7021528233308 7021528233315 7021528233360 7021528233377 7021528233421 7021528233438 7021528233483 7021528233490 7021528233667 7021528233674 7021528233780 7021528233797 7021528233902 7021528233919 7021528233964 7021528233971 7021528234022 7021528234039 7021528234084 7021528234091 7021528285062 7021528285079 7021528285185 7021528285192 7021528285307 7021528285314 7021528285369 7021528285376 7021528285420 7021528285437 7021528285482 7021528285499 7021528285666 7021528285673 Page 153 of 212 EL No. - New Part number Old Part number 828578 828579 828590 828591 828596 828597 828602 828603 Description BFOU-XFR(C) 4TRIP 2.5mm² BFOU-XFR(C) 4TRIP 2.5mm² BFOU-XFR(C) 8TRIP 2.5mm² BFOU-XFR(C) 8TRIP 2.5mm² BFOU-XFR(C) 12TRIP 2.5mm² BFOU-XFR(C) 12TRIP 2.5mm² BFOU-XFR(C) 16TRIP 2.5mm² BFOU-XFR(C) 16TRIP 2.5mm² Sheath Colour GREY BLUE GREY BLUE GREY BLUE GREY BLUE Stock item - EAN No. DNK 7021528285789 7021528285796 7021528285901 7021528285918 7021528285963 7021528285970 7021528286021 7021528286038 EL No. - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 154 of 212 eXtended Fire Resistant, instrumentation cable BFCU-XFR(i) 150/250(300)V, steel wire braided eXtended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFCU-XFR(i) 150/250(300)V MGT/EPR/EPR/GSWB/EVA Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes). IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2 EN 50200:2006 Annex E IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoplastic compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberized Polyamide tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFCU-XFR(I) 250V 4PAIR 1.5mm2 FLEX - FLAME IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) IEC 60331-2*) IEC 603323-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 155 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Inner covering, mm Diameter inner covering, mm 1 2 0.75 1.1 1 1.1 9.5 ± 0.5 0.3 8.5 1.1 1 2 0.75 1.1 1 1.1 9.5 ± 0.5 0.3 8.5 1.1 2 2 0.75 1.1 1 1.1 0.3 11.9 1.3 2 2 0.75 1.1 1 1.1 0.3 11.9 1.3 4 4 8 8 12 12 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.4 1.4 0.3 0.3 0.3 0.3 0.3 0.3 13.6 13.6 17.8 17.8 20.4 20.4 1.4 1.4 1.6 1.6 1.7 1.7 16 2 0.75 1.1 1 1.9 0.3 22.9 1.8 16 2 0.75 1.1 1 1.9 0.3 22.9 1.8 24 24 2 2 0.75 0.75 1.1 1.1 1 1 2.3 2.3 0.46 0.46 47.9 47.9 2.1 2.1 13.5 ± 0.8 13.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 21.5 ± 1 21.5 ± 1 28 ± 1 28 ± 1 33 ± 1.5 33 ± 1.5 37.5 ± 1.5 37.5 ± 1.5 46.5 ± 2 46.5 ± 2 1 3 0.75 1.1 1 1.1 0.3 8.5 1.1 14 ± 0.8 330 24 1 3 0.75 1.1 1 1.1 0.3 8.5 1.1 14 ± 0.8 330 24 2 2 3 3 0.75 0.75 1.1 1.1 1 1 1.1 1.1 0.3 0.3 11.9 11.9 1.4 1.4 20 ± 1 20 ± 1 550 550 47 47 4 3 0.75 1.1 1 1.1 0.3 15.3 1.4 23 ± 1 780 93 4 3 0.75 1.1 1 1.1 0.3 15.3 1.4 23 ± 1 780 93 8 8 12 12 16 16 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1 1 1 1 1 1 1.1 1.1 1.4 1.4 2.1 2.1 10.5 ± 0.8 10.5 ± 0.8 16 ± 0.8 16 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 31 ± 1.5 31 ± 1.5 36 ± 1.5 36 ± 1.5 0.3 0.3 0.3 0.3 0.3 0.3 20.4 20.4 22.9 22.9 25.4 25.4 1.7 1.7 1.8 1.8 1.9 1.9 1310 1310 1810 1810 2470 2470 186 186 279 279 371 371 24 3 0.75 1.1 1 2.5 45 ± 2 0.46 53.8 2.2 3770 557 24 3 0.75 1.1 1 2.5 45 ± 2 0.46 53.8 2.2 30 ± 1.5 30 ± 1.5 36 ± 1.5 36 ± 1.5 41.5 ± 2 41.5 ± 2 51.5 ± 2.5 51.5 ± 2.5 3770 557 1 2 1.5 1.6 1 1.1 0.3 8.5 1.2 350 34 1 2 1.5 1.6 1 1.1 0.3 8.5 1.2 350 34 2 2 4 4 8 8 2 2 2 2 2 2 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.1 1.1 0.3 0.3 0.3 0.3 0.3 0.3 11.9 11.9 15.3 15.3 20.4 20.4 1.4 1.4 1.5 1.5 1.7 1.7 14.5 ± 0.8 14.5 ± 0.8 20.5 ± 1 20.5 ± 1 23.5 ± 1 23.5 ± 1 31 ± 1.5 31 ± 1.5 560 560 820 820 1360 1360 68 68 136 136 272 272 12 2 1.5 1.6 1 1.4 0.3 22.9 1.9 37 ± 1.5 1900 408 12 2 1.5 1.6 1 1.4 0.3 22.9 1.9 37 ± 1.5 1900 408 Subject to change without prior notice 14.5 ± 0.8 14.5 ± 0.8 17 ± 0.8 17 ± 0.8 23.5 ± 1 23.5 ± 1 28 ± 1 28 ± 1 32.5 ± 1.5 32.5 ± 1.5 40.5 ± 2 40.5 ± 2 10.5 ± 0.8 10.5 ± 0.8 16 ± 0.8 16 ± 0.8 19 ± 0.8 19 ± 0.8 26 ± 1 26 ± 1 31.5 ± 1.5 31.5 ± Thickness Outer Sheath, mm Weight Diameter of outer Cable sheath, Approx. mm (Kg/Km) Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Copper content Approx. (kg/km) 300 17 300 17 470 34 470 34 650 650 1060 1060 1450 1450 67 67 134 134 200 200 1920 267 1920 267 2980 2980 400 400 Page 156 of 212 Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Weight Diameter of outer Cable sheath, Approx. mm (Kg/Km) Copper content Approx. (kg/km) 0.46 0.46 0.46 0.46 41.9 41.9 53.8 53.8 2.1 2.1 2.4 2.4 43 ± 2 43 ± 2 52 ± 2.5 52 ± 2.5 2750 2750 3880 3880 544 544 816 816 0.3 8.5 1.2 390 49 0.3 8.5 1.2 390 49 0.3 13.6 1.5 22 ± 1 680 97 0.3 13.6 1.5 22 ± 1 680 97 0.3 0.3 0.3 0.3 15.3 15.3 20.4 20.4 1.6 1.6 1.8 1.8 25.5 ± 1 25.5 ± 1 33 ± 1.5 33 ± 1.5 1000 1000 1680 1680 193 193 386 386 0.3 25.4 2 41 ± 2 2460 579 0.3 25.4 2 41 ± 2 2460 579 0.46 0.46 0.46 0.46 47.9 47.9 59.8 59.8 2.2 2.2 2.6 2.6 47.5 ± 2 47.5 ± 2 58 ± 2.5 58 ± 2.5 3510 3510 5080 5080 772 772 1157 1157 0.3 8.5 1.2 390 55 0.3 8.5 1.2 390 55 0.3 13.6 1.5 22 ± 1 660 109 0.3 13.6 1.5 22 ± 1 660 109 0.3 0.3 15.3 15.3 1.6 1.6 970 970 218 218 1.1 28.5 ± 1 0.3 20.4 1.8 1620 435 1 1.1 28.5 ± 1 0.3 20.4 1.8 1620 435 2 2 2 2 1 1 1 1 2.3 2.3 2.3 2.3 36 ± 1.5 36 ± 1.5 40.5 ± 2 40.5 ± 2 0.3 0.3 0.46 0.46 25.4 25.4 47.9 47.9 2 2 2.2 2.2 25.5 ± 1 25.5 ± 1 33.5 ± 1.5 33.5 ± 1.5 41.5 ± 2 41.5 ± 2 46.5 ± 2 46.5 ± 2 2550 2550 3370 3370 652 652 869 869 2.5 2.5 2.5 2.5 2.5 2.5 2 2 2 2 2 2 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.1 1.1 0.3 0.3 0.3 0.3 0.3 0.3 10.2 10.2 15.3 15.3 17.8 17.8 1.2 1.2 1.5 1.5 1.6 1.6 16 ± 0.8 16 ± 0.8 23.5 ± 1 23.5 ± 1 27.5 ± 1 27.5 ± 1 450 450 790 790 1200 1200 78 78 155 155 310 310 3 2.5 2 1 1.3 0.3 22.9 2 36 ± 1.5 2120 619 8 3 2.5 2 1 1.3 0.3 22.9 2 36 ± 1.5 2120 619 12 12 3 3 2.5 2.5 2 2 1 1 2.6 2.6 12 ± 0.8 12 ± 0.8 19 ± 0.8 19 ± 0.8 22.5 ± 1 22.5 ± 1 30.5 ± 1.5 30.5 ± 1.5 40.5 ± 2 40.5 ± 2 0.46 0.46 47.9 47.9 2.2 2.2 47 ± 2 47 ± 2 929 929 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Diameter inner covering, mm 16 16 24 24 2 2 2 2 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 2.1 2.1 2.3 2.3 1.5 37 ± 1.5 37 ± 1.5 45.5 ± 2 45.5 ± 2 1 3 1.5 1.6 1 1.1 1 3 1.5 1.6 1 1.1 2 3 1.5 1.6 1 1.1 2 3 1.5 1.6 1 1.1 4 4 8 8 3 3 3 3 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 1.1 1.1 1.1 1.1 12 3 1.5 1.6 1 1.6 12 3 1.5 1.6 1 1.6 16 16 24 24 3 3 3 3 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1 1 1 1 2.3 2.3 2.7 2.7 1 2 2.5 2 1 1.1 1 2 2.5 2 1 1.1 2 2 2.5 2 1 1.1 2 2 2.5 2 1 1.1 4 4 2 2 2.5 2.5 2 2 1 1 1.1 1.1 11.5 ± 0.8 11.5 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 20.5 ± 1 20.5 ± 1 8 2 2.5 2 1 8 2 2.5 2 12 12 16 16 2 2 2 2 2.5 2.5 2.5 2.5 1 1 2 2 4 4 3 3 3 3 3 3 8 Subject to change without prior notice 11.5 ± 0.8 11.5 ± 0.8 17.5 ± 0.8 17.5 ± 0.8 21 ± 1 21 ± 1 28 ± 1 28 ± 1 35.5 ± 1.5 35.5 ± 1.5 41 ± 2 41 ± 2 51 ± 2.5 51 ± 2.5 15.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 3520 3520 Page 157 of 212 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Shielded pair 0,75 mm² Shielded triple 0,75 mm² 65 65 0,94 0,94 26,3 26,3 17,9 17,9 Shielded pair 1,5 mm² Shielded triple 1,5 mm² 80 80 0,84 0,84 12,9 12,9 32,6 32,6 Shielded pair 2,5 mm² Shielded triple 2,5 mm² 100 100 0,77 0,77 8,02 8,02 48 48 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 821000 821001 821006 821007 821018 821019 821030 821031 821036 821037 821042 821043 821048 821049 BFCU-XFR(I) 1PAIR 0.75mm² BFCU-XFR(I) 1PAIR 0.75mm² BFCU-XFR(I) 2PAIR 0.75mm² BFCU-XFR(I) 2PAIR 0.75mm² BFCU-XFR(I) 4PAIR 0.75mm² BFCU-XFR(I) 4PAIR 0.75mm² BFCU-XFR(I) 8PAIR 0.75mm² BFCU-XFR(I) 8PAIR 0.75mm² BFCU-XFR(I) 12PAIR 0.75mm² BFCU-XFR(I) 12PAIR 0.75mm² BFCU-XFR(I) 16PAIR 0.75mm² BFCU-XFR(I) 16PAIR 0.75mm² BFCU-XFR(I) 24PAIR 0.75mm² BFCU-XFR(I) 24PAIR 0.75mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528210002 7021528210019 7021528210064 7021528210071 7021528210187 7021528210194 7021528210309 7021528210316 7021528210361 7021528210378 7021528210422 7021528210439 7021528210484 7021528210491 - 821060 821061 821066 821067 821078 821079 821090 821091 821096 821097 821102 821103 821108 821109 BFCU-XFR(I) 1TRIP 0.75mm² BFCU-XFR(I) 1TRIP 0.75mm² BFCU-XFR(I) 2TRIP 0.75mm² BFCU-XFR(I) 2TRIP 0.75mm² BFCU-XFR(I) 4TRIP 0.75mm² BFCU-XFR(I) 4TRIP 0.75mm² BFCU-XFR(I) 8TRIP 0.75mm² BFCU-XFR(I) 8TRIP 0.75mm² BFCU-XFR(I) 12TRIP 0.75mm² BFCU-XFR(I) 12TRIP 0.75mm² BFCU-XFR(I) 16TRIP 0.75mm² BFCU-XFR(I) 16TRIP 0.75mm² BFCU-XFR(I) 24TRIP 0.75mm² BFCU-XFR(I) 24TRIP 0.75mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528210606 7021528210613 7021528210668 7021528210675 7021528210781 7021528210798 7021528210903 7021528210910 7021528210965 7021528210972 7021528211023 7021528211030 7021528211085 7021528211092 - 821400 821401 821406 821407 821418 821419 821430 821431 821436 821437 821442 821443 821448 821449 BFCU-XFR(I) 1PAIR 1.5mm² BFCU-XFR(I) 1PAIR 1.5mm² BFCU-XFR(I) 2PAIR 1.5mm² BFCU-XFR(I) 2PAIR 1.5mm² BFCU-XFR(I) 4PAIR 1.5mm² BFCU-XFR(I) 4PAIR 1.5mm² BFCU-XFR(I) 8PAIR 1.5mm² BFCU-XFR(I) 8PAIR 1.5mm² BFCU-XFR(I) 12PAIR 1.5mm² BFCU-XFR(I) 12PAIR 1.5mm² BFCU-XFR(I) 16PAIR 1.5mm² BFCU-XFR(I) 16PAIR 1.5mm² BFCU-XFR(I) 24PAIR 1.5mm² BFCU-XFR(I) 24PAIR 1.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528214000 7021528214017 7021528214062 7021528214079 7021528214185 7021528214192 7021528214307 7021528214314 7021528214369 7021528214376 7021528214420 7021528214437 7021528214482 7021528214499 - GREY BLUE GREY - 7021528214604 7021528214611 7021528214666 - 821460 BFCU-XFR(I) 1TRIP 1.5mm² 821461 BFCU-XFR(I) 1TRIP 1.5mm² 821466 BFCU-XFR(I) 2TRIP 1.5mm² Subject to change without prior notice Page 158 of 212 New Part number Old Part number 821467 821478 821479 821490 821491 821496 821497 821502 821503 821508 821509 Description Sheath Colour Stock item EAN No. DNK EL No. BFCU-XFR(I) 2TRIP 1.5mm² BFCU-XFR(I) 4TRIP 1.5mm² BFCU-XFR(I) 4TRIP 1.5mm² BFCU-XFR(I) 8TRIP 1.5mm² BFCU-XFR(I) 8TRIP 1.5mm² BFCU-XFR(I) 12TRIP 1.5mm² BFCU-XFR(I) 12TRIP 1.5mm² BFCU-XFR(I) 16TRIP 1.5mm² BFCU-XFR(I) 16TRIP 1.5mm² BFCU-XFR(I) 24TRIP 1.5mm² BFCU-XFR(I) 24TRIP 1.5mm² BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528214673 7021528214789 7021528214796 7021528214901 7021528214918 7021528214963 7021528214970 7021528215021 7021528215038 7021528215083 7021528215090 - 828700 828701 828706 828707 828718 828719 828730 828731 828736 828737 828742 828743 BFCU-XFR(I) 1PAIR 2.5mm² BFCU-XFR(I) 1PAIR 2.5mm² BFCU-XFR(I) 2PAIR 2.5mm² BFCU-XFR(I) 2PAIR 2.5mm² BFCU-XFR(I) 4PAIR 2.5mm² BFCU-XFR(I) 4PAIR 2.5mm² BFCU-XFR(I) 8PAIR 2.5mm² BFCU-XFR(I) 8PAIR 2.5mm² BFCU-XFR(I) 12PAIR 2.5mm² BFCU-XFR(I) 12PAIR 2.5mm² BFCU-XFR(I) 16PAIR 2.5mm² BFCU-XFR(I) 16PAIR 2.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528287004 7021528287011 7021528287066 7021528287073 7021528287189 7021528287196 7021528287301 7021528287318 7021528287363 7021528287370 7021528287424 7021528287431 - 828760 828761 828766 828767 828778 828779 828790 828791 828796 828797 BFCU-XFR(I) 1TRIP 2.5mm² BFCU-XFR(I) 1TRIP 2.5mm² BFCU-XFR(I) 2TRIP 2.5mm² BFCU-XFR(I) 2TRIP 2.5mm² BFCU-XFR(I) 4TRIP 2.5mm² BFCU-XFR(I) 4TRIP 2.5mm² BFCU-XFR(I) 8TRIP 2.5mm² BFCU-XFR(I) 8TRIP 2.5mm² BFCU-XFR(I) 12TRIP 2.5mm² BFCU-XFR(I) 12TRIP 2.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528287608 7021528287615 7021528287660 7021528287677 7021528287783 7021528287790 7021528287905 7021528287912 7021528287967 7021528287974 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 159 of 212 eXtended Fire Resistant, instrumentation cable BFCU-XFR(c) 150/250(300)V, steel wire braided eXtended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFCU-XFR(c) 150/250(300)V MGT/EPR/EPR/GSWB/EVA Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Meets the mud resistant requirements in NEK TS 606:2009. Cables have extended fire resistant (XFR) properties to IEC 60331-1&2 including water spray according to EN 50200 Annex E (90 minutes). IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2 EN 50200:2006 Annex E IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Manufacturing unit Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberized Polyamide tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA 01 BFCU-XFR(C) 250V 4PAIR 1.5mm2 FLEX - FLAME IEC 60092-376 EN 50200:2006 Annex E IEC 60331-1*) or IEC 60331-2*) IEC 60332-3-22 DRAKA 01 = Draka Norsk Kabel Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm Subject to change without prior notice Page 160 of 212 Core identification instrumentation cables Pair - Black - Light Blue Triple - Black - Light Blue - Brown Quad - Black - Light Blue - Brown - Grey Range and dimensions Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Weight Diameter of outer Cable sheath, Approx. mm (Kg/Km) Copper content Approx. (kg/km) 0.3 0.3 10.2 10.2 1.3 1.3 18 ± 0.8 440 18 ± 0.8 440 30 30 0.3 11.9 1.3 20.5 ± 1 580 56 0.3 11.9 1.3 20.5 ± 1 580 56 0.3 0.3 0.3 0.3 17.8 17.8 20.4 20.4 1.5 1.5 1.6 1.6 960 960 1290 1290 107 107 159 159 1.9 29.5 ± 1 0.3 22.9 1.7 1680 210 1 1.9 29.5 ± 1 0.3 22.9 1.7 26.5 ± 1 26.5 ± 1 31 ± 1.5 31 ± 1.5 34.5 ± 1.5 34.5 ± 1.5 1680 210 1.1 1 2.3 0.46 41.9 2 42.5 ± 2 2550 313 0.75 1.1 1 2.3 0.46 41.9 2 42.5 ± 2 2550 313 3 3 0.75 0.75 1.1 1.1 1 1 1.1 1.1 0.3 0.3 11.9 11.9 1.3 1.3 20 ± 1 20 ± 1 530 530 43 43 4 3 0.75 1.1 1 1.1 0.3 15.3 1.4 23 ± 1 750 82 4 3 0.75 1.1 1 1.1 0.3 15.3 1.4 23 ± 1 750 82 8 8 12 12 16 16 24 24 3 3 3 3 3 3 3 3 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1 1 1 1 1 1 1 1 1.1 1.1 1.4 1.4 2.1 2.1 2.5 2.5 0.3 0.3 0.3 0.3 0.3 0.3 0.46 0.46 17.8 17.8 22.9 22.9 25.4 25.4 47.9 47.9 1.6 1.6 1.7 1.7 1.8 1.8 2.1 2.1 29.5 ± 1 29.5 ± 1 35 ± 1.5 35 ± 1.5 39 ± 1.5 39 ± 1.5 48.5 ± 2 48.5 ± 2 1210 1210 1670 1670 2220 2220 3370 3370 159 159 237 237 314 314 469 469 2 2 1.5 1.6 1 1.1 0.3 11.9 1.4 20 ± 1 540 62 2 2 1.5 1.6 1 1.1 0.3 11.9 1.4 20 ± 1 540 62 4 2 1.5 1.6 1 1.1 0.3 15.3 1.4 22.5 ± 1 750 118 4 2 1.5 1.6 1 1.1 0.3 15.3 1.4 22.5 ± 1 750 118 8 8 2 2 1.5 1.5 1.6 1.6 1 1 1.1 1.1 15.5 ± 0.8 15.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 0.3 0.3 17.8 17.8 1.7 1.7 1220 1220 230 230 12 2 1.5 1.6 1 1.4 29.5 ± 1 0.3 22.9 1.8 1670 342 12 2 1.5 1.6 1 1.4 29.5 ± 1 0.3 22.9 1.8 1670 342 16 2 1.5 1.6 1 1.9 33 ± 1.5 0.3 25.4 1.9 2160 454 16 2 1.5 1.6 1 1.9 33 ± 1.5 0.3 25.4 1.9 2160 454 24 24 2 2 1.5 1.5 1.6 1.6 1 1 2.3 2.3 41 ± 2 41 ± 2 47.9 47.9 2.2 2.2 30 ± 1.5 30 ± 1.5 34.5 ± 1.5 34.5 ± 1.5 38.5 ± 1.5 38.5 ± 1.5 47.5 ± 2 47.5 ± 2 3290 3290 678 678 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Diameter inner covering, mm 2 2 2 2 0.75 0.75 1.1 1.1 1 1 1.1 1.1 4 2 0.75 1.1 1 1.1 4 2 0.75 1.1 1 1.1 8 8 12 12 2 2 2 2 0.75 0.75 0.75 0.75 1.1 1.1 1.1 1.1 1 1 1 1 1.1 1.1 1.4 1.4 14 ± 0.8 14 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 22 ± 1 22 ± 1 26.5 ± 1 26.5 ± 1 16 2 0.75 1.1 1 16 2 0.75 1.1 24 2 0.75 24 2 2 2 Subject to change without prior notice 36.5 ± 1.5 36.5 ± 1.5 16 ± 0.8 16 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 25 ± 1 25 ± 1 30 ± 1.5 30 ± 1.5 34 ± 1.5 34 ± 1.5 42.5 ± 2 42.5 ± 2 0.46 0.46 Page 161 of 212 Mechanical Diameter crossBraid section of Wire, the braid, mm mm² Thickness Outer Sheath, mm Weight Diameter of outer Cable sheath, Approx. mm (Kg/Km) Copper content Approx. (kg/km) 0.3 13.6 1.4 22 ± 1 660 91 0.3 13.6 1.4 22 ± 1 660 91 0.3 0.3 0.3 0.3 0.3 0.3 15.3 15.3 20.4 20.4 25.4 25.4 1.5 1.5 1.8 1.8 1.9 1.9 25.5 ± 1 25.5 ± 1 33 ± 1.5 33 ± 1.5 39 ± 1.5 39 ± 1.5 930 930 1580 1580 2190 2190 175 175 344 344 512 512 0.46 41.9 2.1 44.5 ± 2 3130 681 0.46 41.9 2.1 44.5 ± 2 3130 681 2.7 47.5 ± 2 0.46 53.8 2.4 1 2.7 47.5 ± 2 0.46 53.8 2.4 2 2 1 1 1.1 1.1 0.3 0.3 13.6 13.6 1.4 1.4 2.5 2 1 1.1 0.3 15.3 2 2.5 2 1 1.1 0.3 8 8 2 2 2.5 2.5 2 2 1 1 1.1 1.1 12 2 2.5 2 1 2.1 12 2 2.5 2 1 2.1 16 2 2.5 2 1 2.3 16 2 2.5 2 1 2.3 24 24 2 2 2.5 2.5 2 2 1 1 2.7 2.7 17 ± 0.8 17 ± 0.8 19.5 ± 0.8 19.5 ± 0.8 27 ± 1 27 ± 1 33.5 ± 1.5 33.5 ± 1.5 36.5 ± 1.5 36.5 ± 1.5 45 ± 2 45 ± 2 2 2 4 4 3 3 3 3 2.5 2.5 2.5 2.5 2 2 2 2 1 1 1 1 1.1 1.1 1.1 1.1 19 ± 0.8 19 ± 0.8 22.5 ± 1 22.5 ± 1 8 3 2.5 2 1 8 3 2.5 2 12 12 16 16 3 3 3 3 2.5 2.5 2.5 2.5 2 2 2 2 Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 3 1.5 1.6 1 1.1 2 3 1.5 1.6 1 1.1 4 4 8 8 12 12 3 3 3 3 3 3 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1 1 1 1 1 1 1.1 1.1 1.1 1.1 1.4 1.4 16 3 1.5 1.6 1 2.3 16 3 1.5 1.6 1 2.3 24 3 1.5 1.6 1 24 3 1.5 1.6 2 2 2 2 2.5 2.5 4 2 4 Subject to change without prior notice Diameter inner covering, mm 17.5 ± 0.8 17.5 ± 0.8 21 ± 1 21 ± 1 28 ± 1 28 ± 1 34 ± 1.5 34 ± 1.5 38.5 ± 1.5 38.5 ± 1.5 54.5 ± 2.5 54.5 ± 2.5 4500 1018 4500 1018 21 ± 1 21 ± 1 620 620 101 101 1.5 24 ± 1 880 193 15.3 1.5 24 ± 1 880 193 0.3 0.3 20.4 20.4 1.8 1.8 1480 1480 378 378 0.3 25.4 1.9 2220 562 0.3 25.4 1.9 32 ± 1.5 32 ± 1.5 38.5 ± 1.5 38.5 ± 1.5 2220 562 0.46 41.9 2.1 42.5 ± 2 2920 746 0.46 41.9 2.1 42.5 ± 2 2920 746 0.46 0.46 53.8 53.8 2.4 2.4 52 ± 2.5 4190 52 ± 2.5 4190 1114 1114 0.3 0.3 0.3 0.3 15.3 15.3 17.8 17.8 1.5 1.5 1.6 1.6 780 780 1160 1160 148 148 286 286 1.1 30 ± 1.5 0.3 22.9 1.9 1940 564 1 1.1 30 ± 1.5 0.3 22.9 1.9 1940 564 1 1 1 1 2.6 2.6 2.6 2.6 39 ± 1.5 39 ± 1.5 42.5 ± 2 42.5 ± 2 47.9 47.9 47.9 47.9 2.1 2.1 2.3 2.3 23.5 ± 1 23.5 ± 1 27 ± 1 27 ± 1 35.5 ± 1.5 35.5 ± 1.5 45.5 ± 2 45.5 ± 2 49 ± 2 49 ± 2 3280 3280 3980 3980 842 842 1119 1119 0.46 0.46 0.46 0.46 Page 162 of 212 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² 55 0,94 26,3 17,9 Unshielded triple 0,75 mm² 55 0,94 26,3 17,9 Unshielded pair 1,5 mm² 65 0,89 12,9 32,6 Unshielded triple 1,5 mm² 65 0,89 12,9 32,6 Unshielded pair 2,5 mm² 75 0,77 8,02 48 Unshielded triple 2,5 mm² 75 0,77 8,02 48 Ordering information New Part number Old Part number Description Sheath Colour Stock item EAN No. DNK EL No. 821606 821607 821618 821619 821630 821631 821636 821637 821642 821643 821648 821649 BFCU-XFR(C) 2PAIR 0.75mm² BFCU-XFR(C) 2PAIR 0.75mm² BFCU-XFR(C) 4PAIR 0.75mm² BFCU-XFR(C) 4PAIR 0.75mm² BFCU-XFR(C) 8PAIR 0.75mm² BFCU-XFR(C) 8PAIR 0.75mm² BFCU-XFR(C) 12PAIR 0.75mm² BFCU-XFR(C) 12PAIR 0.75mm² BFCU-XFR(C) 16PAIR 0.75mm² BFCU-XFR(C) 16PAIR 0.75mm² BFCU-XFR(C) 24PAIR 0.75mm² BFCU-XFR(C) 24PAIR 0.75mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528216066 7021528216073 7021528216189 7021528216196 7021528216301 7021528216318 7021528216363 7021528216370 7021528216424 7021528216431 7021528216486 7021528216493 - 821666 821667 821678 821679 821690 821691 821696 821697 821702 821703 821708 821709 BFCU-XFR(C) 2TRIP 0.75mm² BFCU-XFR(C) 2TRIP 0.75mm² BFCU-XFR(C) 4TRIP 0.75mm² BFCU-XFR(C) 4TRIP 0.75mm² BFCU-XFR(C) 8TRIP 0.75mm² BFCU-XFR(C) 8TRIP 0.75mm² BFCU-XFR(C) 12TRIP 0.75mm² BFCU-XFR(C) 12TRIP 0.75mm² BFCU-XFR(C) 16TRIP 0.75mm² BFCU-XFR(C) 16TRIP 0.75mm² BFCU-XFR(C) 24TRIP 0.75mm² BFCU-XFR(C) 24TRIP 0.75mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528216660 7021528216677 7021528216783 7021528216790 7021528216905 7021528216912 7021528216967 7021528216974 7021528217025 7021528217032 7021528217087 7021528217094 - 822006 822007 822018 822019 822030 822031 822036 822037 822042 822043 822048 822049 BFCU-XFR(C) 2PAIR 1.5mm² BFCU-XFR(C) 2PAIR 1.5mm² BFCU-XFR(C) 4PAIR 1.5mm² BFCU-XFR(C) 4PAIR 1.5mm² BFCU-XFR(C) 8PAIR 1.5mm² BFCU-XFR(C) 8PAIR 1.5mm² BFCU-XFR(C) 12PAIR 1.5mm² BFCU-XFR(C) 12PAIR 1.5mm² BFCU-XFR(C) 16PAIR 1.5mm² BFCU-XFR(C) 16PAIR 1.5mm² BFCU-XFR(C) 24PAIR 1.5mm² BFCU-XFR(C) 24PAIR 1.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528220063 7021528220070 7021528220186 7021528220193 7021528220308 7021528220315 7021528220360 7021528220377 7021528220421 7021528220438 7021528220483 7021528220490 - 822066 822067 822078 822079 822090 822091 822096 822097 BFCU-XFR(C) 2TRIP 1.5mm² BFCU-XFR(C) 2TRIP 1.5mm² BFCU-XFR(C) 4TRIP 1.5mm² BFCU-XFR(C) 4TRIP 1.5mm² BFCU-XFR(C) 8TRIP 1.5mm² BFCU-XFR(C) 8TRIP 1.5mm² BFCU-XFR(C) 12TRIP 1.5mm² BFCU-XFR(C) 12TRIP 1.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528220667 7021528220674 7021528220780 7021528220797 7021528220902 7021528220919 7021528220964 7021528220971 - Subject to change without prior notice Page 163 of 212 New Part number Old Part number 822102 822103 822108 822109 Description Sheath Colour Stock item EAN No. DNK EL No. BFCU-XFR(C) 16TRIP 1.5mm² BFCU-XFR(C) 16TRIP 1.5mm² BFCU-XFR(C) 24TRIP 1.5mm² BFCU-XFR(C) 24TRIP 1.5mm² GREY BLUE GREY BLUE - 7021528221022 7021528221039 7021528221084 7021528221091 - 829106 829107 829118 829119 829130 829131 829136 829137 829142 829143 829148 829149 BFCU-XFR(C) 2PAIR 2.5mm² BFCU-XFR(C) 2PAIR 2.5mm² BFCU-XFR(C) 4PAIR 2.5mm² BFCU-XFR(C) 4PAIR 2.5mm² BFCU-XFR(C) 8PAIR 2.5mm² BFCU-XFR(C) 8PAIR 2.5mm² BFCU-XFR(C) 12PAIR 2.5mm² BFCU-XFR(C) 12PAIR 2.5mm² BFCU-XFR(C) 16PAIR 2.5mm² BFCU-XFR(C) 16PAIR 2.5mm² BFCU-XFR(C) 24PAIR 2.5mm² BFCU-XFR(C) 24PAIR 2.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528291063 7021528291070 7021528291186 7021528291193 7021528291308 7021528291315 7021528291360 7021528291377 7021528291421 7021528291438 7021528291483 7021528291490 - 829166 829167 829178 829179 829190 829191 829196 829197 829202 829203 BFCU-XFR(C) 2TRIP 2.5mm² BFCU-XFR(C) 2TRIP 2.5mm² BFCU-XFR(C) 4TRIP 2.5mm² BFCU-XFR(C) 4TRIP 2.5mm² BFCU-XFR(C) 8TRIP 2.5mm² BFCU-XFR(C) 8TRIP 2.5mm² BFCU-XFR(C) 12TRIP 2.5mm² BFCU-XFR(C) 12TRIP 2.5mm² BFCU-XFR(C) 16TRIP 2.5mm² BFCU-XFR(C) 16TRIP 2.5mm² GREY BLUE GREY BLUE GREY BLUE GREY BLUE GREY BLUE - 7021528291667 7021528291674 7021528291780 7021528291797 7021528291902 7021528291919 7021528291964 7021528291971 7021528292022 7021528292039 - Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 164 of 212 Hydraulic and Turbine oils resistant, instrumentation cable BFOV(i) 150/250(300)V Fire resistant, flame retardant halogen-free instrumentation cable. Resistant to turbine and hydraulic oils. BFOV(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 600754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath Marking text Outer sheath colour F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with a PETP tape. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape V Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA NORSK KABEL BFOV(i) 250V 16 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 Grey or Blue *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 165 of 212 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm Diameter inner covering, mm Diameter Braid Wire, mm Thickness Outer Sheath, mm 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 1.1 1 2 0.75 1.1 0.6 1.1 7.5 ± 0.5 0.2 1.1 4 2 0.75 1.1 0.6 1.1 12.5 ± 0.8 0.3 1.4 1 3 0.75 1.1 0.6 1.1 8 ± 0.5 0.2 1.1 4 3 0.75 1.1 0.6 1.1 14 ± 0.8 0.3 1.4 8 3 0.75 1.1 0.6 1.1 0.3 1.7 12 3 0.75 1.1 0.6 1.4 18.5 ± 0.8 22.5 ± 1 0.3 1 2 1.5 1.6 0.7 1.1 9 ± 0.5 1 3 1.5 1.6 0.7 1.1 Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 200 54 200 54 490 183 220 70 570 209 23 ± 1 960 359 1.8 27.5 ± 1 1290 475 0.2 1.1 12 ± 0.8 250 79 9.5 ± 0.5 0.2 1.2 12.5 ± 0.8 285 93 10.5 ± 0.8 10.5 ± 0.8 16.5 ± 0.8 11 ± 0.8 17.5 ± 0.8 Electrical values instrumentation cables Capacitance, approx. (nF/km) Shielded pair 0,75 mm² 110 Shielded triple 0,75 mm² 110 Shielded pair 1,5 mm² 125 Shielded triple 1,5 mm² 125 Shielded pair 2,5 mm² 145 Shielded triple 2,5 mm² 145 Shielded 16 and 24 triple 1,5 mm² 105 Shielded 16 pair 2,5 mm² 110 Type Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 0,71 0,66 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 12,9 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 24,4 41,1 Ordering information New Part number Old Part number 20114120 20114414 Description Sheath Colour Stock item EAN No. DNK EL No. BFOV(I) 1PAIR 0.75mm² BFOV(I) 1PAIR 0.75mm² BFOV(I) 4PAIR 0.75mm² GREY BLUE GREY Yes Yes - 7021528866643 7021528872507 7021528867060 - 886665 BFOV(I) 1TRIP 0.75mm² BFOV(I) 4TRIP 0.75mm² BFOV(I) 8TRIP 0.75mm² BFOV(I) 12TRIP 0.75mm² GREY GREY GREY BLUE - 7021528866650 7021528872521 7021528872538 7021528873054 - 886663 BFOV(I) 1PAIR 1.5mm² GREY - 7021528866636 - 886447 BFOV(I) 1TRIP 1.5mm² GREY - 7021528864472 - 886706 20110587 20114116 20115141 Other no. of pairs/triples and cross sectional area are available on request Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 166 of 212 Hydraulic and Turbine oils resistant, instrumentation cable BFOV(c) 150/250(300)V Fire resistant, flame retardant halogen-free instrumentation cable. Resistant to turbine and hydraulic oils. BFOV(c) 150/250(300)V MGT/EPR/EPR/TCWB/HNBR Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32. IEC 60092-376 (2003-05) IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 600754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape U Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360) Eg. "meter" "year" DRAKA NORSK KABEL BFOV(c) 250V 4 PAIR 0,75 mm2 FLEX - FLAME IEC 60092-376 IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 Grey or Blue Marking text Outer sheath colour *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 167 of 212 Core identification instrumentation cables Pair Black - Light Blue Triple Black - Light Blue - Brown Quad Black - Light Blue - Brown - Grey Range and dimensions Cross Number No of Conductor Insulation section of cores in Diameter, Thickness, core, elements element mm mm mm² Thickness Inner covering, mm 2 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 4 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 8 2 0.75 1.1 0.6 1.1 12 2 0.75 1.1 0.6 8 3 0.75 1.1 0.6 1.1 8 3 0.75 1.1 0.6 1.1 2 2 1.5 1.6 0.7 1.1 4 4 8 2 2 2 1.5 1.5 1.5 1.6 1.6 1.6 0.7 0.7 0.7 8 3 1.5 1.6 0.7 1.1 Diameter inner covering, mm Diameter Braid Wire, mm Thickness Outer Sheath, mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 0.3 1.3 14.5 ± 0.8 340 113 0.3 1.3 16 ± 0.8 440 155 0.3 1.3 16 ± 0.8 440 155 0.3 1.5 20.5 ± 1 680 240 0.3 1.5 20.5 ± 1 680 240 0.3 1.6 23 ± 1 870 308 0.3 1.6 23 ± 1 870 308 13 ± 0.8 0.3 1.4 16.5 ± 0.8 440 162 22.5 ± 1 0.3 1.8 27 ± 1 1270 517 10.5 ± 0.8 12.5 ± 0.8 12.5 ± 0.8 16.5 ± 0.8 16.5 ± 0.8 18.5 ± 0.8 18.5 ± 0.8 Electrical values instrumentation cables Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Unshielded 16 and 24 pair 2,5 mm² Unshielded 16 triple 2,5 mm² 95 95 0,66 0,66 8,02 8,02 41,1 41,1 Ordering information New Part number Old Part number 887204 Description Sheath Colour Stock item EAN No. DNK EL No. 20114046 20115142 20115143 BFOV(C) 2PAIR 0.75mm² BFOV(C) 4PAIR 0.75mm² BFOV(C) 4PAIR 0.75mm² BFOV(C) 8PAIR 0.75mm² BFOV(C) 8PAIR 0.75mm² BFOV(C) 12PAIR 0.75mm² GREY GREY BLUE GREY BLUE BLUE Yes - 7021528872040 7021528872514 7021528867695 7021528872545 7021528873023 7021528873030 - 20113991 20115144 BFOV(C) 8TRIP 0.75mm² BFOV(C) 8TRIP 0.75mm² GREY BLUE - 7021528872552 7021528873047 - BFOV(C) 2PAIR 1.5mm² GREY - 7021528864496 - 20114112 886769 886449 Subject to change without prior notice Page 168 of 212 New Part number 20115151 20115152 20115155 Old Part number 886451 Description Sheath Colour Stock item EAN No. DNK EL No. BFOV(C) 4PAIR 1.5mm² BFOV(C) 4PAIR 1.5mm² BFOV(C) 8PAIR 1.5mm² GREY BLUE GREY - 7021528873061 7021528873078 7021528873085 - BFOV(C) 8TRIP 1.5mm² GREY - 7021528864519 - Other no. of pairs/triples and cross sectional area are available on request. Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 169 of 212 Hydraulic and Turbine oils resistant, power cable BFOV 0,6/1(1,2)kV Fire resistant, flame retardant halogen-free power cable. Resistant to turbine and hydraulic oils. BFOV 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/HNBR Operating temperature Operating Voltage : 90°C : 0,6/1(1,2)kV Standards applied Application Fixed installation for power, control and lighting in both EX- and safe areas, emergency and critical systems where requirement for fire resistance exists. Especially resistant to the following hydraulic oils: HydraWay HVXA 46, Nyco Turbonycoil 600, Nyco Turbonycoil 610, Mobil Glygoyle 11 and Turbway 32. IEC 60092-353 IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-1, -2, -21 IEC 60754-1,2 IEC 61034-1,2 - Design - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/screen Outer sheath B F Tinned annealed stranded circular copper (STCC), IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape O Tinned annealed copper wire braid PET tape V Flame retardant, halogen-free and oil resistant thermoset compound (Therban), SHF2 (IEC 60092-360) E.g. meter" "year" DRAKA NORSK KABEL BFOV 0.6/1kV 3 x 4/6mm² FLEX FLAME IEC 60331-1*) or IEC 60331-2*) IEC 60331-21**) IEC 60332-3-22 Black Marking text Outer sheath colour *) IEC 60331-1 for cables with an overall diameter exceeding 20 mm and IEC 60331-2 for cables with an overall diameter not exceeding 20 mm **) IEC 60331-21 also at enhanced temperature 1000°C for 180 minutes Subject to change without prior notice Page 170 of 212 Core identification power cables Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black Seven cores and above White with black numbers Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey G / X in cable description G = One of the cores are yellow/green - X = no yellow/green core Range and dimensions Cross Cross Number Conductor Insulation section section of Diameter, Thickness, core, screen, elements mm mm mm² mm² Thickness Inner covering, mm Diameter Thickness Diameter inner Outer Braid covering, Sheath, Wire, mm mm mm Diameter outer sheath, mm Weight of Cable Approx. (Kg/Km) Copper content Approx. (kg/km) 2 1.5 4 1.6 1.0 1.1 10 ± 0.8 0.3 1.2 285 79 2 2.5 6 2.0 1.0 1.1 11 ± 0.8 0.3 1.3 360 129 2 6 6 3.15 1.0 1.1 13 ± 0.8 0.3 1.4 13 ± 0.8 14.5 ± 0.8 17 ± 0.8 540 209 3 1.5 6 1.6 1.0 1.1 0.3 1.3 14.5 ± 0.8 350 125 3 2.5 6 2.0 1.0 1.1 0.3 1.3 15 ± 0.8 420 165 3 4 6 2.55 1.0 1.1 13 ± 0.8 0.3 1.3 500 209 3 6 6 3.15 1.0 1.1 0.3 1.4 620 280 3 16 16 5.15 1.0 1.1 14 ± 0.8 18.5 ± 0.8 16.5 ± 0.8 18 ± 0.8 0.4 1.5 23 ± 1 1170 660 10.5 ± 0.8 11.5 ± 0.8 Ordering information New Part number Old Part number 20117367 Description Sheath Colour Stock item EAN No. DNK EL No. 886453 886705 BFOV 0.6/1kV 2X 1.5/4mm² BFOV 0.6/1kV 2X 2.5/6mm² BFOV 0.6/1kV 2X 6/6mm² BLACK BLACK BLACK - 7021528873122 7021528864533 7021528867053 - 886666 886668 886744 BFOV 0.6/1kV 3X 1.5/6mm² BFOV 0.6/1kV 3X 2.5/6mm² BFOV 0.6/1kV 3X 4/6mm² BFOV 0.6/1kV 3X 6/6mm² BFOV 0.6/1kV 3X 16/16mm² BLACK BLACK BLACK BLACK BLACK - 7021528866674 7021528873115 7021528866667 7021528866681 7021528867442 - 20117363 20117365 Other no. of cores and cross sectional area are available on request. Electrical values power cables Number of elements Cross section core, mm² Cross section screen, mm² Conductor type 2 Max. Max. conductor conductor resistance at resistance at 20°C, 90°C, Ohm/km Ohm/km Reactance at 50Hz, Ohm/km Reactance at 60Hz, Ohm/km Current rating IEC 60092-352 Table B.4, Ampere Short circuit rating 1 second, Ampere 2 2 2 1.6 2.5 6 4 6 6 STCC STCC STCC 12.2 7.56 3.11 15.6 9.64 3.97 0.115 0.107 0.094 0.138 0.129 0.112 16 26 44 210 350 840 3 3 3 1.5 2.5 4 6 6 6 STCC STCC STCC 12.2 7.56 4.7 15.6 9.64 5.99 0.115 0.107 0.100 0.138 0.129 0.120 16 21 28 210 350 560 Subject to change without prior notice Page 171 of 212 Number of elements 3 3 Cross section core, mm² 6 16 Cross Conductor Max. Max. Reactance Reactance Current Short section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1 mm² 20°C, 90°C, Table B.4, second, Ohm/km Ohm/km Ampere Ampere 6 STCC 3.11 3.97 0.094 0.112 36 840 16 STCC 1.16 1.48 0.107 0.129 67 2240 Ambient temperature correction factors Ambient Temp °C Rating factor 35 1.10 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.74 70 0.67 75 0.58 80 0.47 Installation recommendations Minimum Bending Radius during Installation 8xD Subject to change without prior notice Minimum Bending Radius Fixed Installed 6xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C Page 172 of 212 Hydro Carbon Fire Resistant Cables Draka Norsk Kabel, part of the Prysmian Group, is a global solution supplier in cables, combining innovation with technological leadership. Draka Norsk Kabel has developed a unique product range for use in critical areas. - a complete range of Hydro Carbon Fire (HCF) resistant cables The design is based on a fire proof elastomeric cable covered with our unique protective composite. Due to its cooling and thermal properties this construction is capable of withstanding hydro carbon fires at 1100°C (2000°F). Excellence centre Research and development is a continuous process at Prysmian Group and Draka Norsk Kabel, the excellence centre in the overall group of specially designed products for Offshore applications, such as the “Hydro Carbon Fire (HCF) resistant cables”. Draka Norsk Kabel has developed considerable expertise in the area of fire resistant cables. Introduced in 1975, the first elastomeric cables were marketed under the name BFOH. In the early eighties, they were replaced by the halogen-free BFOU, part of the Flex-Flame range. Flexible and cost saving installation The “FLEX-FLAME HCF” cable is flexible, easy to install and terminate whereas; similar products, e.g. cables protected with extra thermal insulation, have the disadvantage of a higher derating factor as well as higher installation costs. Mineral insulated cables have the disadvantage of alloy conductors, requiring larger conductor cross-sectional areas, complex, time consuming installation and a limited range. Subject to change without prior notice Page 173 of 212 Properties of the design The unique design of the cable gives good heat transmission during normal operating temperature, thus reducing the requirement for derating. If the cable is exposed to a hydrocarbon fire, rapid changes in the material state will give a cooling effect, which is maintained during the critical period. When this process is completed, the layer will turn into a firm, ceramic substance which provides heat insulation. Consequently, this is why the conductor temperature can be kept at a low level (approx. 500°C/900°F) even if the temperature should exceed 1100°C (2000°F). For Instrument and Communications applications, the values of Capacitance, Inductance, Resistance and Attenuation are not unduly affected. Certifications and approvals According to most current requirements, the cables shall pass the IEC 60331 part 21 gas flame test at 750°C (1350°F) for minimum 90 minutes without short circuit. This test temperature however, is more typical to cellulose fires, not to hydrocarbon fires, the latter being more common in Refineries, Petrochemical Industry and Production/Drilling Rigs. The HCF cables will function in hydrocarbon fires exceeding 1100°C / 2000°F for a period of 30-60 minutes, in accordance with EN 1363-2 / ISO 834. See fig. below. Considering this important fact may be more crucial than enduring 90 minutes at lower temperatures (750 – 1000°C / 1350 – 1850°F). The outstanding performance of the HCF cable from Draka Norsk Kabel satisfies both requirements. Subject to change without prior notice Page 174 of 212 The product portfolio range The “FLEX-FLAME HCF” 1100°C (2000°F) cables cover the entire range from Instrument and Telecommunications cables to Medium Voltage and High Voltage Power cables as described below. Application: Cable type/voltage: Fire class: Instrument and Telecommunication Control Power L.V. Power M.V. BFOU HCF 250 V BFOU HCF 0,6/1 kV BFOU HCF 0,6/1 kV RFOU HCF 6/10 (12) kV RFOU HCF 8,7/15 (17.5) kV RFOU HCF 12/20 (24) kV RFOU HCF 18/30 (36) kV RFOU HCF 26/45 (52) kV QFCI HCF H-30 H-30 H-30 – H-60 H-60 H-60 H-60 H-60 H-60 H-30 Power H.V. Optical fibre cable Our state-of-the-art cable systems support many major customers in the oil, gas and petrochemical industry. Now years of research and development within Draka Norsk Kabel has resulted in a range of cables, specially designed for the Hydrocarbon Processing Industry’s most critical systems: Fire and Gas Detection, Emergency Shutdown, Communications Systems etc. Subject to change without prior notice Page 175 of 212 Hydro Carbon Fire resistant instrument cable BFOU-HCF(i) 150/250(300)V, S15 HydroCarbon Fire resistant, flame retardant halogen-free instrumentation cable. BFOU-HCF(i) 150/250(300)V 1 5 4 2 3 MGT/EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code S15 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital. IEC 60092-376 (2003-05) Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1 IEC 60332-3-22 IEC 60331-21 EN 1363-2 / ISO 834 IEC 600754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape Overall sheath Marking text Outer sheath colour F Tinned stranded circular copper, IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360) Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 Grey, Blue or Black -HCF Subject to change without prior notice Page 176 of 212 Core identification instrumentation cables Black - Light Blue Pair Black - Light Blue - Brown Triple Range and dimensions New Part Old Part number number Type [mm2] 20118210 886723 Grey 1 pair 0,75 887086 Blue 1 pair 0,75 886722 Blue Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) 7.5 ± 0.5 0.2 7.5 ± 0.5 0.2 1 triple 0,75 8,0 ± 0,5 0,2 886563 Grey 886714 Blue 886751 Black Grey 886802 Grey Grey 886803 Grey 886804 Grey 886805 Grey 1 pair 1,5 1 pair 1,5 1 pair 1,5 2 pair 1,5 4 pair 1,5 5 pair 1,5 8 pair 1,5 10 pair 1,5 12 pair 1,5 9,0±0,5 9,0±0,5 9,0±0,5 13,0±0,8 15,5±0,8 17.0±0,8 21.0±1,0 24,0±1.0 25,0±1,0 886710 Grey Grey 1 triple 1,5 12 triple 1.5 Grey 1 pair 2.5 10.5 ± 0.8 10.5 ± 0.8 Weight of cable approx. [kg/km] 37.0 ± 1,5 1500 37.0 ± 1,5 1500 11,0 ± 0,8 37,5 ± 1,5 1640 0,2 0,2 0,2 0,3 0,3 0,3 0,3 0,3 0,3 12,0±0,8 12,0±0,8 12,0±0,8 17,0±0,8 19,5±0,8 21,0±1,0 25,5±1,0 29,0±1,0 30.0±1,5 38,5±1,5 38,5±1,5 38,5±1,5 44,0±2,0 47,0±2,0 48,5±2,0 53.0±2,5 57,0±2,5 63,0±3.0 1880 1880 1880 2360 2730 2950 3570 9,5 ± 0,5 28.5 ± 1 0,2 0.3 12,5±0.8 33.5 ± 1.5 39,5±1,5 66.5 ± 3.0 1870 5770 9.5 ± 0.5 0.2 13.0 ± 0.8 39.5 ± 1.5 1900 5060 Other no. of cores and cross sectional area are available on request. Electrical values instrumentation cables Capacitance, approx. Type (nF/km) Shielded pair 0,75 mm² 110 Shielded triple 0,75 mm² 110 Shielded pair 1,5 mm² 125 Shielded triple 1,5 mm² 125 Shielded pair 2,5 mm² 145 Shielded triple 2,5 mm² 145 Subject to change without prior notice Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 Page 177 of 212 Installation recommendations TYPE Overall Diameter [mmØ] [mm2] Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D Maximum pulling tension [N] 1 pair 0,75 1 triple 0,75 37.0 ± 1,5 37,5 ± 1,5 740 750 444 450 75 112,5 1 pair 1,5 2 pair 1,5 4 pair 1,5 5 pair 1,5 8 pair 1,5 10 pair 1,5 12 pair 1,5 38,5±1,5 44.0±2,0 47,0±2,0 48,5±2,0 53.0±2,5 57,0±2,5 63,0±3.0 770 880 940 970 1060 1140 1260 462 528 564 582 636 684 756 150 300 600 750 1200 1500 1800 1 triple 1,5 12 triple 1.5 39.5 ± 1.5 66.5 ± 3.0 790 1330 474 798 225 2700 1 pair 2.5 39.5 ± 1.5 790 474 250 Minimum installation temperature: - 10 °C Subject to change without prior notice Page 178 of 212 Hydro Carbon Fire resistant instrument cable BFOU-HCF(c) 150/250(300)V, S16 HydroCarbon Fire resistant, flame retardant halogen-free instrumentation cable. BFOU-HCF(c) 150/250(300)V 1 5 4 2 3 MGT/EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code S16 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 150/250(300)V Standards applied Application Fixed installation for instrumentation, communication, control and alarm systems in both EX- and safe areas, emergency and critical systems where requirement for hydrocarbon fire resistance is vital. IEC 60092-376 (2003-05) Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 EN 1363-2 / ISO 834 IEC 60754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation B Pair / Triple / Quad twisting Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape Overall sheath F Tinned stranded circular copper, IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire.Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic compound PET tape O Tinned copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-360) Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF(c) 250V S16 4 PAIR 1,5 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 Grey, Blue or Black -HCF Marking text Outer sheath colour Subject to change without prior notice Page 179 of 212 Core identification instrumentation cables Black - Light Blue Pair Black - Light Blue - Brown Triple Range and dimensions New Part Old Part number number Type [mm2] Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) Weight of cable approx. [kg/km] 886681 Black 8 pair 0,75 16.5±0.8 0.3 20.5± 1 40.5 ± 3 2790 886761 Blue 886562 Grey 886752 Black 886709 Grey 886762 Black 2 pair 1,5 4 pair 1,5 8 pair 1,5 12 pair 1,5 24 pair 1,5 13,0±0,8 15,0±0,8 20,0±1,0 24,0±1,0 33,5±1,5 0,3 0,3 0,3 0,3 0,4 16,5±0,8 19,0±0,8 24,5±1,0 28,5±1,0 39,5±1,5 44,0±2,0 46,0±2,0 52,5±2,5 56,5±2,5 72,5±3,5 2310 2600 3410 4030 6930 Other no. of cores and cross sectional area are available on request. Electrical values instrumentation cables TYPE Capacitance Inductance approx. approx. [mm2] [nF/km] [mH/km] Unshielded pair 0.75mm² Unshielded pair 1,5 Installation recommendations TYPE Overall Diameter [mmØ] [mm2] 100 110 Resist. 20°C L/R ratio, (microH/Ohm) [Max.ohm/km] 0.67 0,63 26.3 12,9 Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D 12.7 24,4 Maximum pulling tension [N] 8 pair 0.75 40.5±2.0 810 486 600 2 pair 1,5 4 pair 1,5 8 pair 1,5 12 pair 1,5 24 pair 1,5 44,5±2,0 46,0±2,0 52,5±2,5 56,0±2,5 72,5±3,5 890 920 1050 1120 1450 534 552 630 672 870 300 600 1200 1800 3600 Minimum installation temperature: - 10°C Subject to change without prior notice Page 180 of 212 Hydro Carbon Fire resistant power cable BFOU-HCF 0,6/1(1,2)kV, P34 HydroCarbon Fire resistant, flame retardant halogen-free power cable. BFOU-HCF 0,6/1(1,2)kV MGT/EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code P34 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 0,6/1kV Standards applied Application Fixed installation for power, control and lightning in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital. IEC 60092-353 Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 EN 1363-2 / ISO 834 IEC 600754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape B F O U -HCF Overall sheath Marking text Outer sheath colour Subject to change without prior notice Tinned stranded circular copper, IEC 60228 class 2 Mica-tape + EP-rubber, IEC 60092-360 (EPR) Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic compound PET tape Tinned copper wire braid PET tape Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360) Eg. "meter" "år" DRAKA NORSK KABEL BFOU-HCF 0,6/1kV P34 12 x 2,5/10 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22 Black Page 181 of 212 Core identification power cables Single core Black Blue – Brown Two cores Blue - Brown - Yellow/green Two cores + earth Brown - Black – Grey Three cores Brown - Black - Grey - Yellow/green Three cores + earth Blue - Brown - Black – Grey Four cores Blue - Brown - Black - Grey - Yellow/green Four cores + earth Blue - Brown - Black - Grey - Black Five cores Above five cores Black numbers on white base Range and dimensions New Part Old Part number number Type [mm2] 886549 886375 886700 886338 885499 885882 885138 Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) 1x 50/6 1x 70/6 1x 95/10 1x 120/10 1x 150/10 1x 185/10 1x 240/16 1x 300/16 15,0±0,8 16,5±0,8 18,5±0,8 20,5±1,0 23,0±1,0 25,0±1,0 28,0±1,0 30,5±1,5 0,20 0,30 0,30 0,30 0,30 0,30 0,30 0,30 18,5±0,8 20,5±1,0 23,0±1,0 25,0±1,0 27,0±1,0 29,5±1,0 32,5±1,5 35,5±1,5 45,5±2,5 47,5±2,5 50,5±3,0 52,5±3,0 54,5±3,0 57,5±3,0 66,0±3,5 68,0±3,5 2900 3300 3800 4260 4750 5380 7050 8000 2x 1,5/4 2x 2,5/6 10,0±0,8 11,0±0,8 0,20 0,30 13,0±0,8 14,5±0,8 40,5±2,5 42,0±2,5 1890 2080 3x 1,5/4 3x 2,5/6 3x 4/6 3x 6/6 3x 16/16 3x 35/16 3x 70/35 3x 120/60 3x 150/70 10,5±0,8 11,5±0,8 13,0±0,8 14,0±0,8 18,5±0,8 25,0±1,0 33,0±1,5 41,0±2,0 46,0±2,0 0,20 0,30 0,30 0,30 0,40 0,30 0,50 0,60 0,40 * 14,0±0,8 15,0±0,8 16,5±0,8 18,0±0,8 23,0±1,0 29,5±1,0 39,0±1,5 48,0±2,0 54,5±2,5 42.0±2,5 42,5±2,5 43,0±2,5 45,0±2,5 50,0±3,0 57,5±3,0 72,0±4,0 81,5±4,5 88,5±4,5 2140 2200 2400 2600 3500 4840 8150 11300 13300 14.0 ± 0.8 0.30 18.0 ± 0.8 19.5 ± 0.8 22.0 ± 1.0 25.0 ± 1.0 45.5 ± 2.5 2580 47.5 ± 2.5 2870 50.0 ± 3.0 3180 53,5±3,0 3750 16.5 ± 0.8 18.0 ± 0.8 19.5 ± 0.8 22.0 ± 1.0 44,0±2,5 2300 45,5 ± 2,5 2650 47,5±2,5 2870 50.0 ± 3.0 3180 886799 3x 4 + E 886174 3x 6 + E 15.5 ± 0.8 0.30 886680 3x 10 + E 18.0 ± 0.8 0.30 886175 3x 16 + E 20.5 ± 1.0 0.30 886547 4x 2,5/6 12.5 ± 0.8 0.30 14.0 ± 0.8 0.30 15.5 ± 0.8 0.30 18.0 ± 0.8 0.30 4x 4/6 886607 4x 6/6 4x 10/10 Subject to change without prior notice Weight of cable approx. [kg/km] Page 182 of 212 New Part number Old Part number Type [mm2] Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) 25.5 ± 53,0 ± 3,0 20.5 ± 1.0 0.40 1.0 25.0 ± 1.0 0.30 29.5 ± 58.5 ± 3.0 1.0 Weight of cable approx. [kg/km] 886546 4x 16/16 3830 886644 4x 25/16 886676 4x 10 + E 20.0 ± 1.0 0.3 24.0 ± 1.0 52.5 ± 3.0 3540 886608 885139 7x 1,5/6 12x 1,5/10 14,0±0,8 18,5±0,8 0,30 0,30 17,5±0,8 22,5±1,0 44,5±2,5 50,0±3,0 2550 3140 885124 886036 7x 2,5/6 12x 2,5/10 15,0±0,8 20,5±1,0 0,30 0,30 19,0±0,8 24,5±1,0 46,0±2,5 52,0±3,0 2760 3500 886548 886645 27x 1,5/16 37x 1,5/16 26.5±1.0 30.0 ±1.5 0.30 0.30 31.0±1.5 35.5 ± 1.5 64,5±3,5 69.0 ± 3.5 5070 5920 4730 * This cable has a double braid (two layers of wires) Other no. of cores and cross sectional area are available on request. ELECTRICAL DATA No. of cores Conductor resistance x cross DC section [/km] at 20 °C at 90 °C Reactance [/km] at 50 / 60 Hz Impedance [/km] at 90 °C At 50 / 60 Hz Continous current rating at 45 °C Short circuit [Ampere] 1 sec 0,3 sec 1 X 50/6 1 X 70/6 1 X 95/10 1 X 120/10 1 X 150/10 1 X 185/10 1 X 240/16 1 X 300/16 0,391 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607 0,4986 0,344 0,2486 0,1964 0,161 0,128 0,0972 0,0774 0,161/0,193 0,152/0,182 0,146/0,176 0,141/0,170 0,137/0,164 0,133/0,160 0,133/0,159 0,128/0,154 0,524/0,535 0,376/0,390 0,289/0,305 0,242/0,260 0,211/0,223 0,185/0,205 0,165/0,187 0,150/0,173 196 242 293 339 389 444 522 601 7000 9800 13300 16800 21000 25900 3360 42000 12780 17892 24282 30672 38340 47286 61344 76681 2x 1,5/4 2x 2,5/6 12,2 7,56 15,56 9,64 0,115/0,138 0,107/0,129 15,556/15,567 9,640/9,641 20 26 210 350 383 639 3x 1,5/4 3x 2,5/6 3x 4/6 3x 6/6 3x 16/16 3x 35/16 3x 70/35 3x 120/60 3x 150/70 12,2 7,56 4,70 3,11 1,16 0,529 0,270 0,154 0,126 15,56 9,64 5,99 3,97 1,46 0,675 0,344 0,196 0,161 0,115/0,138 0,107/0,129 0,100/0,120 0,094/0,112 0082/0,099 0,078/0,094 0,077/0,092 0,073/0,088 0,073/0,088 15,556/15,567 9,640/9,641 5,993/5,994 3,967/3,9672 1,481/1,482 0,679/0,681 0,352/0,356 0,209/0,215 0,177/0,183 16 21 28 36 67 110 169 237 272 210 350 560 840 2240 4900 9800 16800 21000 383 639 1022 1534 4089 8946 17892 30672 38340 3x 4 + E 3x 6 + E 3x 10 + E 3x 16 + E 4,70 3,11 1.84 1,16 5,99 3,97 2.35 1,46 0,100/0,120 0,094/0,112 0.088/0.105 0082/0,099 5,993/5,994 3,967/3,9672 2.351/2.352 1,481/1,482 28 36 50 67 560 840 1400 2240 1022 1534 2556 4089 Subject to change without prior notice Page 183 of 212 No. of cores x cross section Conductor resistance DC [/km] at 20 °C at 90 °C Reactance [/km] at 50 / 60 Hz Impedance [/km] at 90 °C At 50 / 60 Hz Continous current rating at 45 °C Short circuit [Ampere] 1 sec 0,3 sec 4x 2,5/6 4x 4/6 4x 6/6 4x 10/10 4x 16/16 4x 25/16 7,56 4,70 3,11 1.84 1,16 0.734 9,64 5,99 3,97 2.35 1,46 0.936 0,107/0,129 0.100/0.120 0,094/0,112 0.088/0.105 0082/0,099 0.081/ 9,640/9,641 5,991/5,9912 3,967/3,9672 2.351/2.352 1,481/1,482 0.098 21 28 36 50 67 89 350 560 840 1400 2240 3500 639 1022 1534 2556 4089 6390 4x 10 + E 1.84 2.35 0.088/0.105 2.351/2.352 50 1400 2556 7x 1,5/6 12x 1,5/10 12,2 12,2 15,56 15,56 0,115/0,138 0,115/0,138 15,556/15,567 15,556/15,567 12 10 210 210 383 383 7x 2,5/6 12x 2,5/10 7,56 7,56 9,64 9,64 0,107/0,129 0,107/0,129 9,640/9,641 9,640/9,641 15,5 13 350 350 639 639 27x 1,5/16 37x 1,5/16 12,2 12,2 15,56 15,56 0,115/0,138 0,115/0,138 15,556/15,567 15,556/15,567 7,5 7 210 210 383 383 INSTALLATION DATA TYPE Overall Diameter [mmØ] [mm2] Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D Maximum pulling tension [N] 1x 50/6 1x 70/6 1x 95/10 1x 120/10 1x 150/10 1x 185/10 1x 240/16 1x 300/16 45,5±2,5 47,5±2,5 50,5±3,0 52,5±3,0 54,5±3,0 57,5±3,0 66,0±3,5 68,0±3,5 910 950 1010 1050 1090 1150 1320 1360 546 570 606 630 654 690 792 816 2500 3500 4750 6000 7500 9250 12000 15000 2x 1,5/4 2x 2,5/6 40,5±2,5 42,0±2,5 810 840 486 504 150 250 3x 1,5/4 3x 2,5/6 3x 4/6 3x 6/6 3x 16/16 3x 35/16 3x 70/35 3x 120/60 3x 150/70 42,0±2,5 42,5±2,5 43,0±2,5 45,0±2,5 50,0±3,0 57,5±3,0 72,0±4,0 81,5±4,5 88,5±4,5 840 850 860 900 1000 1150 1440 1630 1770 504 510 516 540 600 690 864 978 1062 225 375 600 900 2400 5250 10500 18000 20000 3x 4 + E 3x 6 + E 3x 10 + E 3x 16 + E 45.5 ± 2.5 47.5 ± 2.5 50.0 ± 3.0 53,5±3,0 910 950 1000 1070 546 570 600 642 800 1200 2000 3200 Subject to change without prior notice Page 184 of 212 TYPE [mm2] Overall Diameter [mmØ] Minimum bending radius During Fixed Installation Installed [mm] 880 528 910 546 950 570 1000 600 1060 636 1170 702 Maximum pulling tension [N] 4x 2,5/6 4x 4/6 4x 6/6 4x 10/10 4x 16/16 4x 25/16 44,0±2,5 45,5 ± 2,5 47,5±2,5 50.0 ± 3.0 53,0 ± 3,0 58.5 ± 3.0 4x 10 + E 52.5 ± 3.0 1050 630 2500 7x 1,5/6 12 x 1,5/10 44,5±2,5 50,0±3,0 890 1000 536 600 525 900 7x 2,5/6 12x 2,5/10 46,0±2,5 52,0±3,0 920 1040 552 624 875 1500 27x 1,5/16 37x 1.5/16 64,5±3,5 69.0 ± 3.5 1290 1380 774 828 2025 2775 500 800 1200 2000 3200 5000 Minimum installation temperature: - 10 °C Subject to change without prior notice Page 185 of 212 Hydro Carbon Fire resistant MV power cable RFOU-HCF 6/10(12)kV, P30 HydroCarbon Fire resistant, flame retardant halogen-free medium voltage power cable. RFOU-HCF 6/10(12)kV EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code P30 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 6/10(12)kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital. IEC 60092-354 Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 and -31 EN 1363-2 / ISO 834 IEC 600754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360) Eg. "meter" "year" DRAKA NORSK KABEL RFOU-HCF 6/10(12)kV P30 1x 70/16 mm2 HCF 1100/60 FLEX - FLAME Red -HCF Overall sheath Marking text Outer sheath colour Subject to change without prior notice Page 186 of 212 Range and dimensions New Part Old Part number number Type Diameter Thickness of Diameter Diameter over bedding armour sheath overall HCF[mm] wires protection [mmØ] [mm] (mm) [mm2] 886498 886795 887247 887182 Weight of cable approx. [kg/km] 1x 70/16 1x 95/16 1x 120/20 1x 150/19 1x 185/18 1x 240/21 1x 300/29 23,5±1,5 25,5±1,5 27,5±1,5 28,5±1,5 30,5±1,5 33,0±1,5 35,0±1,5 0,3 0,3 0,3 0,3 0,3 0,3 0,3 30,0±2,0 32,0±2,0 34,0±2,0 35,0±2,0 36,5±2,0 39,0±2,0 41,5±2,5 62,0±3,0 64,5±3,0 66,5±3,0 67,5±3,0 69,0±3,0 72,0±3,5 74,5±3,5 5220 5900 6340 6670 7320 8250 9280 3x 50/31 47,0±2,0 0,4 55,0±3,0 89,0±4,5 10970 Other no. of cores and cross sectional area are available on request. Type Diameter of copper conductor approx. mmØ Insulation thickness, nominal mm Semiconducting layer thickness approx. mm Diameter over insulated, screened conductor, approx. mm 1x 70/16 1x 95/16 1x 120/20 1x 150/19 1x 185/18 1x 240/21 1x 300/29 10,3 12,1 13,6 15,1 16,8 19,1 21.5 3,4 3,4 3,4 3,4 3,4 3,4 3,4 0,8 0,8 0,8 0,8 0,8 0,8 0,8 21,5 23,0 24,5 26,0 28,0 30,0 32,5 3x 50/31 8,8 3,4 0,8 20,0 (mm²) ELECTRICAL DATA No. of cores Conductor resistance x cross DC section [/km] [mm2] at 20 °C at 90 °C Reactance [/km] at 50 Hz Impedance [/km] at 90 °C at 50 Hz Continous current rating at 45 °C Short circuit (conductor) [Ampere] 1 sec 0,3 sec 1x 70/16 1x 95/16 1x 120/20 1x 150/19 1x 185/18 1x 240/21 1x 300/29 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 0,172 0,164 0,159 0,153 0,148 0,143 0,137 0,385 0,298 0,253 0,222 0,195 0,173 0,158 242 293 339 389 444 522 601 9800 13300 16800 21000 25900 33600 42000 17892 24282 30672 38340 47286 61344 76681 3x 50/31 0,391 0,499 0,108 0,261 137 7000 12780 Subject to change without prior notice Page 187 of 212 INSTALLATION DATA TYPE Overall Diameter [mmØ] [mm2] Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D Maximum pulling tension [N] 1 x70/16 1x 95/16 1x 120/20 1x 150/19 1x 185/18 1x 240/21 1x 300/29 62,0±3,0 64,5±3,0 66,5±3,0 67,5±3,0 69,0±3,0 72,0±3,5 74,5±3,5 1240 1290 1330 1350 1380 1440 1490 744 774 798 810 828 864 894 3500 4750 6000 7500 9250 12000 15000 3x 50/31 89,0±4,5 1780 1068 7500 Minimum installation temperature: - 10 °C The RFOU-HCF MV cables are available on request in all voltage levels from 3,6/6(7,2)kV up to and including 26/45(52)kV. Please be aware that we have a limitation on the cable diameter which allows us to manufacture mainly single core cables on these voltage levels. Subject to change without prior notice Page 188 of 212 Hydro Carbon Fire resistant MV power cable RFOU-HCF 8,7/15(17,5)kV, P31 HydroCarbon Fire resistant, flame retardant halogen-free medium voltage power cable. RFOU-HCF 8,7/15(17,5)kV EPR/EPR/TCWB/EVA/HCF/SHF1 NEK 606 Code P31 1100°C / 2000°F / 200 kW/m² Operating temperature Operating Voltage : 90°C : 8,7/15(17,5)kV Standards applied Application Fixed installation for medium voltage (MV) power in both EX- and safe areas, emergency and critical systems where requirement for fire resistance is vital. IEC 60092-354 Draka Norsk Kabel IEC 60228 class 2 IEC 60092-360 IEC 60092-360 IEC 60332-1-2 IEC 60332-3-22 IEC 60331-21 EN 1363-2 / ISO 834 IEC 600754-1,2 IEC 61034-1,2 - Design - HCF protection - Conductor - Insulation - Sheath - Flame Retardant - Flame Retardant - Fire Resistant - HC Fire resistance - Halogen Free - Low Smoke Construction Code Letter Conductor Conductor screen semiconductive Insulation Insulation screen semicoductive Tinned stranded and compressed copper (STCC), IEC 60228 class 2 Semiconductive layer (EP-rubber) R Lay up / Shielding Inner covering Tape over bedding Armour/screen Tape over armour/screen Outer sheath HCF protection Tape F EP-rubber, IEC 60092-360 (EPR) Semiconductive layer (EP-rubber) Cores are laid up together. Cores are identified by Brown, Black or Grey threads under and over the metallic screen on each conductor. Flame retardant and halogen-free thermoset compound PET tape O Tinned copper wire braid PET tape U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC 60092-360) Extruded heatblock compound Lapped glassfibre tape Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092360) Eg. "meter" "year" DRAKA NORSK KABEL RFOU-HCF 8,7/15(17,5)kV P31 3x 35/35 mm2 HCF 1100/60 FLEX - FLAME Red -HCF Overall sheath Marking text Outer sheath colour Subject to change without prior notice Page 189 of 212 Range and dimensions New Part Old Part number number Type Diameter over bedding [mm] [mm2] Thickness of armour wires [mmØ] Diameter sheath Diameter overall HCFprotection [mm] Weight of cable approx. [kg/km] (mm) Type 1x 70/20 1x 120/20 26.0 ± 1.5 29.5 ± 1.5 0.4 0.4 32.0 ± 1.5 36.0 ± 2.0 64.5 ± 3.0 69.0 ± 3.0 5750 6850 3x 35/35 49,0 ± 2,0 0,5 57,5 ± 3,0 92,0 ± 4,5 11600 Diameter of copper conductor approx. mmØ Insulation thickness, nominal mm Semiconducting layer thickness approx. mm Diameter over insulated, screened conductor, approx. mm 1x 70/20 1x 120/20 10.3 13.6 4.5 4.5 0.8 0.8 21.8 26.0 3x 35/35 7.4 4.5 0.8 19.6 (mm²) ELECTRICAL DATA No. of Conductor resistance cores x DC cross [/km] section [mm2] at 20 °C at 90 °C Reactance [/km] Impedance [/km] at 90 °C Continous current rating Short circuit (conductor) [Ampere] at 50 Hz at 50 Hz at 45 °C 1 sec 0,3 sec 1x 70/20 1x 120/20 0.270 0.154 0.339 0.193 0.130 0.120 0.156 0.144 225 320 9800 16800 17892 30672 3x 35/35 0.529 0.675 0.122 0.685 100 4900 8946 INSTALLATION DATA TYPE Overall Diameter [mmØ] [mm2] Minimum bending radius During Fixed Installation Installed [mm] 20 x D 12 x D Maximum pulling tension [N] 1x 70/20 1x 120/20 64.5 ± 3.0 69.0 ± 3.0 1290 1380 774 828 3500 6000 3x 35/35 92,0±4,5 1840 1104 5250 Minimum installation temperature: - 10°C The RFOU-HCF MV cables are available on request in all voltage levels from 3,6/6(7,2)kV up to and including 26/45(52)kV. Please be aware that we have a limitation on the cable diameter which allows us to manufacture mainly single core cables on these voltage levels. Subject to change without prior notice Page 190 of 212 Approvals Our cables carry these major approvals: RFOU (c) 250V RFOU (i) 250V RFOU (c) 250V Arctic Grade RFOU (i) 250V Arctic Grade RU (c) 250V RU (i) 250V RFOU 0,6/1 kV RFOU 0,6/1 kV Arctic Grade RFOU 3,6/6(7,2)kV RFOU 6/10(12) kV RFOU 8,7/15(17,5) kV RFOU 12/20(24) kV RU 0,6/1 kV UX 1000V BFOU (c) 250V BFOU (i) 250V BFOU (c) 250V Arctic Grade BFOU (i) 250V Arctic Grade BFOU-XFR (c) 250V BFOU-XFR (i) 250V BFCU-XFR (c) 250V BFCU-XFR (i) 250V BU (c) 250V BU (i) 250V BFOU 0,6/1 kV BFOU 0,6/1 kV Arctic Grade BU 0,6/1kV BFCU (c) 250V BFCU (i) 250V BFCU 0,6/1kV RFCU (c) 250V RFCU (i) 250V RFCU 0,6/1kV QFCI AICI ToughCat 5e S/FTP ToughCat 7 S/FTP ToughCat 7S S/FTP DET NORSKE VERITAS AMERICAN BUREAU OF SHIPPING LLOYDS REGISTER OF SHIPPING BUREAU VERITAS RUSSIAN MARITIME REGISTER OF SHIPPING All cables are designed in accordance with IEC 60092-350, IEC 60092-353, IEC 60092-354 and IEC 60092-376 except those marked with *) . They are designed in accordance with BS 6883 Subject to change without prior notice Page 191 of 212 Standards and tests Standards Designation Title IEC 60092-350 Electrical installations in ships Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications IEC 60092-352 Electrical installations in ships Part 352: Choice and installation of electrical cables IEC 60092-353 Electrical installations in ships – Part 353: Single and multicore non-radial field power cables with extruded solid insulation for rated voltage 1 kV and 3 kV. IEC 60092-354 Electrical installations in ships – Part 354: Single -and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2kV) up to 30 kV (Um = 36 kV) IEC 60092-360 Electrical installations in ships – Part 359: Insulating and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunication cables IEC 60092-376 Electrical installations in ships – Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) IEC 60228 Conductors of insulated cables. IEC 60331-1 Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm IEC 60331-2 Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm IEC 60331-3 Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure IEC 60331-11 Test for electric cables under fire conditions – Circuit integrity – Part 11 Apparatus – Fire alone at a flame temperature of at least 750°C IEC 60331-21 Test for electric cables under fire conditions – Circuit integrity – Part 21 Procedures and requirements – Cables of rated voltage up to and including 0,6/1kV IEC 60331-25 Test for electric cables under fire conditions – Circuit integrity – Part 25 Procedures and requirements – Optical fibre cables IEC 60332-1-1 Test on electric and optical fibre cables under fire conditions. Part 1-1 Test for vertical flame propagation for a single insulated wire or cable - Apparatus IEC 60332-1-2 Test on electric and optical fibre cables under fire conditions. Part 1-2 Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame IEC 60332-1-3 Test on electric and optical fibre cables under fire conditions. Part 1-3 Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles IEC 60332-2-1 Test on electric and optical fibre cables under fire conditions. Part 2-1 Test for vertical flame propagation for a single small insulated wire or cable - Apparatus IEC 60332-2-2 Test on electric and optical fibre cables under fire conditions. Part 2-2 Test for vertical flame propagation for a single small insulated wire or cable – Procedure Subject to change without prior notice Page 192 of 212 Standards Designation Title for diffusion flame IEC 60332-3-10 Tests on electric and optical fibre cables under fire conditions. Part 3-10: test for vertical flame spread of vertically-mounted bunched wires or cables – Apparatus IEC 60332-3-21 Tests on electric cables under fire conditions. Part 3-21 Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A F/R IEC 60332-3-22 Tests on electric and optical fibre cables under fire conditions. Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category A IEC 60332-3-23 Tests on electric and optical fibre cables under fire conditions. Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category B IEC 60332-3-24 Tests on electric and optical fibre cables under fire conditions. Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category C IEC 60332-3-25 Tests on electric and optical fibre cables under fire conditions. Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables – Category D IEC 60445 Basic and safety principles for man-machine interface, marking and identification – Identification of equipment terminals, conductor terminations and conductors Test on gases evolved during combustion of electrical cables. Part 1: Determination of the amount of halogen acid gas. IEC 60754-1 IEC 60754-2 Test on gases evolved during combustion of electrical cables. Part 2: Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity. IEC 60811-100 Electric and optical fibre cables – Test methods for non-metallic materials – Part 100: General IEC 61034-1 Measurement of smoke density of cables burning under defined conditions. Part 1: Test apparatus. IEC 61034-2 Measurement of smoke density of cables burning under defined conditions. Part 2: Test procedure and requirements. IEC 61892-4 Mobile and fixed offshore units Electrical installations – Part 4: Cables Subject to change without prior notice Page 193 of 212 Definition of terms Flame retardance The cables shall withstand the test specified in IEC 60332-3-22/-23/-24. Single, earth and bonding wires shall withstand the test specified in IEC 60332-1-2. Fire resistance Fire resistant cables shall be tested in accordance with IEC 60331-1, 60331-2, 60331-21 and IEC 60331-25 (optical fibre cables). Content of halogen To demonstrate that the cables are halogen-free they shall be tested to IEC 60754-1; - maximum content of halogen = 5 mg/g. Alternatively the cables shall be tested to IEC 60754-2; - pH value should not be less than 4,3 - The conductivity value should not exceed 10 µS/mm. Smoke Emission During a cable fire the smoke emission is recommended to have a minimum value of 60% when tested in accordance with IEC 61034-2 Oil resistance For cables with thermoplastic sheath material there are no requirements for oil resistance properties. All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be demonstrated by a test according to IEC 60092-360 SHF-2 with the cable immersed in IRM oil no. 902 at 100°C for 24 hours. Mud resistance In accordance with NEK TS 606 the mud resistant cables shall have a sheath that complies with the requirements in IEC 60092-360 for SHF2 and the below specified. Mud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD unless otherwise specified. The MUD resistance test requirements for sheathing compounds are as follows: Test fluid Temperature Duration Tensile strength variation Elongation at break variation Volume swell variation Weight increase variation Mineral oil type IRM 903 100°C 7d 30% 30% 30% 30% Calcium Bromide Brine (Waterbased) 70°C 56 d 25% 25% 20% 15% EDC-95-11 (Oil based) 70°C 56 d 25% 25% 20% 15% Subject to change without prior notice Page 194 of 212 Fire, flame, smoke and corrosion test methods Cables' integrity during a fire Fire resistance During a fire it is vital that emergency circuits should continue to function. This could be communication circuits, emergency lights, alarms and fire pumps, etc. On oil rigs and platforms and other confined areas this could be a matter of life and death. Cables that will function in a fire ensuring circuit integrity BFOU / BFCU / BU cables These cable types have Mica tape applied around the conductors which are then insulated with heat-resistant EPDM and have and outer sheathing of a halogen-free thermoset material. BFOU cables have metal braid armour between the insulation and outer sheathing. Test method IEC 60331 -21 and -25, 750°C fire for 90 minutes. As an option we offer cables to 1000°C for 3 hours with an upgraded IEC 60331-21 and -25 test. IEC 60331-1 or 60331-2 fire test at 830°C for 90 minutes with hammer shock Our range of BFOU-XFR with eXtended Fire Resistant properties can also withstand the IEC 60331-1 or 60331-2 fire test at 830°C for 90 minutes with hammer shock (every 5 minutes) followed by 90 minutes fire with waterspray in accordance with EN 50200 ANNEX E + hammershock every 5 minutes Flame propagation Flame retardant cables must be self-extinguishing when the source of flames dies out. Flame retardant cables with built-in self-extinguishing properties These cables have sheathing and bedding with hydrated flame retardants that provide resistance to ignition and flame spread. Test methods IEC 60332 – 1 IEC 60332 – 3 – 22/23/24 (category A, B and C, respectively) IEC 60332 - 3 (Category) Amount of combustible material in litres per metre of cable ladder Burning time Minutes - 22 (Cat. A) - 23 (Cat. B) - 24 (Cat. C) 7 3,5 1,5 40 40 20 Subject to change without prior notice Page 195 of 212 Smoke risk to personnel Smoke evolution is of major significance in situations where escape routes are limited in the event of fire. Cables having exceptionally low smoke emission All offshore topside cables and fire resistant cables listed in this catalogue, have sheathing and insulation based on halogen-free materials. To minimize the risk of smoke and toxic gases, each component from conductor tapes to outer sheath has been taken into consideration. Test method 3 m Cube Test for the measurement of smoke density. IEC 61034 - 2 Damage to expensive equipment Corrosion Halogen-free cables will not cause corrosion to metals. When halogen - containing cables burn, the gases generated in combustion of the sheathing and insulation may cause corrosion. The secondary effects after a fire are often many times larger than the damages caused by the fire itself. Test method IEC 60754 - 1 IEC 60754 - 2 Subject to change without prior notice Page 196 of 212 Installation recommendations The following installation recommendations are in accordance with IEC regulations and practice. Different regulations may apply in other countries. Minimum cable bending radius. Cables for rated voltages up to 0,6/1 kV, in accordance with IEC 60092-352. Outer diameter of cable D < 25mm D > 25mm Minimum bending radius when fixed installed Unbraided cables Braided cables 4D 6D Minimum bending radius during installation 6D 6D 8D 8D Medium voltage cables up to and including 12/20(24) kV: Minimum bending radius during installation: Minimum bending radius when fixed installed: 15D 9D Installation temperature. Minimum recommended installation temperature for cables of rated voltage up to 30 kV, such as: RFOU – BFOU – RU – BU -20°C RFOU – BFOU Arctic Grade -40°C Pulling tension. The cable pulling tension during installation can be estimated by means of the following formula: p= 50 N total cross section of conductors in the armoured cable 25 N total cross section of conductors in the unarmoured cable or p= Additional tension will be supplied from the braid and the insulation and sheathing compound. Subject to change without prior notice Page 197 of 212 Electrical data Conductor Resistance Resistance formula: L R=p A R = resistance in ohm per phase Ohm mm2 p = specific resistance m A = conductor area mm², L = conductor length, m Resistance as a function of temperature: R = R0 (1 + (t-20 C)) R = Resistance at t=20C, t = conductor temperature °C, = 0,00393 for copper Conductor resistance tinned annealed copper 250V. In accordance with IEC 60092-376. Nominal No. of wires conductor and diameter area of wires Approx. diam. mm² mm mmØ 0,5 0,75 1 1,5 2,5 7x 0,30 7x 0,36 7x 0,43 7x 0,525 7x 0,67 0,9 1,1 1,3 1,6 2,0 Max. resistance pr km 20°C ohm 41,6 26,3 19,3 12,9 8,02 90°C ohm 53,0 33,5 24,6 16,4 10,2 Conductor resistance tinned annealed copper 0,6/1kV, 1,8/3(3,6)kV. In accordance with IEC 60228, class 2. Tinned stranded annealed copper conductors for single core and multicore cables 0,6/1kV and 1,8/3kV Nominal conductor area No. of wires and diameter of wires Approx. diam. mm² mm mmØ 1 1,5 2,5 4 6 10 16 25 35 50 70 95 7x 0,43 7x 0,525 7x 0,67 7x 0,85 7x 1,05 7x 1,35 7x 1,71 7 x 2,15 19x 1,53 19x 1,80 19x 2,17 37x 1,80 1,3 1,6 2,0 2,55 3,15 4,05 5,15 6,45 7,65 9,1 10,85 12,6 Subject to change without prior notice Max. resistance pr km 20°C ohm 18,2 12,2 7,56 4,70 3,11 1,84 1,16 0,734 0,529 0,391 0,270 0,195 90°C ohm 23,2 15,6 9,64 5,99 3,97 2,35 1,48 0,936 0,675 0,499 0,344 0,249 Page 198 of 212 Nominal conductor area No. of wires and diameter of wires Approx. diam. mm² 120 150 185 240 300 400 500 630 mm 37x 2,03 37x 2,27 37x 2,52 61x 2,24 61x 2,52 91x 2,36 91x 2,64 127x 2,52 mmØ 14,2 15,9 17,7 20,15 22,6 26,0 29,0 32,8 Max. resistance pr km 20°C ohm 0,154 0,126 0,100 0,0762 0,0607 0,0475 0,0369 0,0286 90°C ohm 0,196 0,161 0,128 0,0972 0,0774 0,0606 0,0463 0,0359 Conductor resistance, tinned annealed copper conductor 3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV, 12/20(24)kV and 18/30(36)kV. In accordance with IEC 60228, class 2. Compressed tinned stranded annealed copper conductors for single core and multicore cables 3,6/6kV, 6/10kV, 8,7/15kV, 12/20(24)kV and 18/30(36)kV. Nominal conductor area No. of wires and diameter of wires *) Approx. diam. mm² mm mmØ 16 25 35 50 70 95 120 150 185 240 300 7x 1,71 7 x 2,14 19x 1,53 19x 1,80 19x 2,17 37x 1,80 37x 2,03 37x 2,27 37x 2,52 61x 2,24 61x 2,52 5,2 6,5 7,4 8,8 10,3 12,1 13,6 15,1 16,8 19,1 21,5 Max. resistance pr km 20°C ohm 1,16 0,734 0,529 0,391 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607 90°C ohm 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 *) Diameter of wires before compressing Subject to change without prior notice Page 199 of 212 Wire gauge conversion table US Standard cross-section to square millimetres U.S. Standard Equivalent cross-section mm² Nearest available cross-section mm² 20 AWG 18 16 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 250 MCM 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1250 1500 1750 2000 0.519 0.823 1.31 2.08 3.31 5.26 8.37 13.30 21.15 33.62 42.41 53.49 67.23 85.01 107.2 126.7 152.0 177.3 202.7 228.0 253.4 278.7 304.0 329.4 354.7 380.0 405.4 430.7 456.0 481.4 506.7 633.4 760.0 886.7 1013.4 0.5 – 0.75 1.0 1.5 2.5 4 6 10 16 25 35 50 50 - 70 70 95 120 120 - 150 150 185 185 185-240 240 240 – 300 300 300 300 – 400 400 400 400 400 400 400 – 630 630 800 800 – 1000 1000 Subject to change without prior notice Page 200 of 212 Current ratings for 250V and 0,6/1kV cables in fixed installations. Current carrying capacities in continuous service at maximum rated temperature of 90°C. In accordance with IEC 60092-352 (2005) Annex B, Table B.4. Ambient temperature 45°C Conductor area mm² 1-core Amp 2-core Amp 3-4 core Amp 1 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 18 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac 15 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511 587 dc / 570 ac 663 dc / 612 ac 757 dc / 663 ac 13 16 21 28 36 50 67 89 110 137 169 205 237 273 311 365 421 483 dc / 469 ac 546 dc / 504 ac 623 dc / 546 dc For cables with more than 4 cores, the current ratings are given by the following formula: I1 I= 3 N I1 = current rating for single core N = number of cores No. of cores 1,5 mm² Amp 2,5 mm² Amp 5 7 12 19 24 37 13 12 10 9 8 7 18 16 13 11 10 9 Subject to change without prior notice Page 201 of 212 Current rating for 1,8/3(3,6)kV, 3,6/6(7,2)kV, 6/10(12)kV, 8,7/15(17,5)kV, 12/20(24)kV and 18/30(36)kV cables in fixed installations. Current carrying capacities in continuous service at maximum rated temperature of 90°C. In accordance with IEC 60092-352 (2005) Annex B, Table B.4. Conductor area mm² 1-core Amp 2-core Amp 3-4 core Amp 16 25 35 50 70 95 120 150 185 240 300 400 500 630 96 127 157 196 242 293 339 389 444 522 601 690 dc / 670 ac 780 dc / 720 ac 890 dc / 780 ac 82 108 133 167 206 249 288 331 377 444 511 - 67 89 110 137 169 205 237 273 311 365 421 - The tabled current ratings must be adjusted for ambient air temperatures other than 45°C. Appropriate rating factors are: Ambient air temp. °C Rating factors 35 40 45 50 55 60 65 70 75 80 1,10 1,05 1,00 0,94 0,88 0,82 0,74 0,67 0,58 0,47 Subject to change without prior notice Page 202 of 212 Short circuit ratings The following short circuit currents are for cables normally operating at a maximum conductor temperature of 90°C. The theoretical temperature that arises in the conductor during a short circuit, which is used as a basis of the calculation, is 250°C. EPR and XLPE insulation are capable of withstanding short term temperatures up to 250°C.The short circuit currents for copper conductors given in the table are values for one second, for other durations the current may be calculated from the following formula: I It = t It = short ciricut current for t sec. (Amp), l = short circuit current for one sec. (Amp), t = short circuit duration (sec.) The duration of the short circuit based on these assumptions should be between 0,2 sec. and 5 sec. Conductor area mm² Current 1 second amperes Conductor area mm² Current 1 second amperes 1,0 1,5 2,5 4 6 10 16 25 35 50 140 210 350 560 840 1400 2240 3500 4900 7000 70 95 120 150 185 240 300 400 500 630 9800 13300 16800 21000 25900 33600 42000 56000 70000 88200 Reactance The reactance of a cable operating in an AC system depends on many factors, including, in particular, the axial spacing between conductors and the proximity and magnetic properties of adjacent steelwork. The former is known for multicore cable, but may vary for single core cables depending upon the spacing between them and their disposition when installed. Reactance of cables in certain disposition when installed. Reactance of cables in certain dispositions remote from steelwork are calculable and are shown. The tabulated values are for cables with circular conductors. The value for a sector-shaped conductor should be taken as 90% of the calculated value. Induction for 2-, 3- and 4- conductor cables is given by the formula: 2a -6 L = 0,2 * ( In ( ) + 0,25 ) * 10 d L = Induction in H/m and phase, a = Axial space between conductors in mm. d = conductor diameter in mm. Reactance for 2-, 3- and 4-conductor cables is given by the formula: X=2**f*L*I X = Reactance in ohm pr. Phase, f = frequency in Hz, L = Induction in H/m and phase I = Conductor length in meter. Reactance Values for Cables Power and control cables. RFOU 0,6/1 kV Subject to change without prior notice Page 203 of 212 Crosssection 2-, 3- and 4 cores ohm/km mm² 60 Hz 50 Hz 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0,132 0,123 0,115 0,108 0,101 0,096 0,095 0,092 0,092 0,088 0,088 0,086 0,087 0,086 0,086 0,086 0,110 0,103 0,096 0,090 0,084 0,080 0,079 0,076 0,076 0,074 0,073 0,072 0,072 0,072 0,072 0,071 1- core* ohm/km 60 Hz 0,140 0,132 0,128 0,125 0,119 0,116 0,113 0,111 0,109 0,107 0,105 50 Hz 0,116 0,110 0,106 0,104 0,099 0,097 0,094 0,092 0,091 0,089 0,087 *) Reactance for 1-conductor cables given at Three- foil formation Power and control cables, BFOU 0,6/1 kV. Cross- section 2-, 3- and 4 core ohm/km mm² 60 Hz 50 Hz 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0,138 0,129 0,120 0,112 0,105 0,099 0,098 0,094 0,093 0,090 0,090 0,088 0,088 0,088 0,087 0,086 0,115 0,107 0,100 0,094 0,088 0,082 0,081 0,078 0,078 0,075 0,075 0,073 0,073 0,073 0,072 0,072 1- core* ohm/km 60 Hz 0,142 0,136 0,129 0,126 0,120 0,116 0,114 0,112 0,110 0,108 0,106 50 Hz 0,118 0,114 0,108 0,105 0,100 0,097 0,095 0,094 0,092 0,090 0,088 *) Reactance for 1-conductor cables given at Three- foil formation Subject to change without prior notice Page 204 of 212 Medium Voltage Power cables. RFOU 6/10 kV Cross3 core 1- core* section ohm/km ohm/km mm² 50 Hz 60 Hz 50 Hz 60 Hz 16 25 35 50 70 95 120 150 185 240 300 400 500 630 0.119 0.119 0.114 0.108 0.103 0.098 0.095 0.092 0.092 0.087 0.084 - 0.154 0.144 0.138 0.132 0.125 0.119 0.116 0.111 0.108 0.104 0.104 0.090 0.097 0.092 0.143 0.143 0.137 0.130 0.124 0.118 0.114 0.111 0.111 0.104 0.101 - 0.185 0.173 0.166 0.158 0.150 0.142 0.139 0.133 0.130 0.125 0.124 0.118 0.117 0.110 *) Reactance for 1-conductor cables given at Three- foil formation Medium Voltage Power cables. RFOU 12/20(24)kV. Cross3 core 1-core* section ohm/km ohm/km mm² 50 Hz 60 Hz 50 Hz 60 Hz 35 50 70 95 120 150 185 240 300 0.128 0.121 0.115 0.109 0.105 0.102 0.099 0.095 - 0.149 0.140 0.133 0.127 0.124 0.119 0.116 0.112 0.108 0.153 0.145 0.135 0.131 0.126 0.122 0.118 0.114 - 0.178 0.169 0.160 0.152 0.149 0.142 0.139 0.134 0.130 *) Reactance for 1-conductor cables given at Three- foil formation Impedance Induction for 2-, 3- and 4- conductor cables is given by the formula: Z= (R +X ) 2 2 Z = Impedansce in ohm pr. phase, R = Resistance at operating temprature in ohm pr. phase. X = Reactance in ohm pr. phase. Subject to change without prior notice Page 205 of 212 Electrical characteristics for instrumentation and telecommunication cables such as 250 V cables: RFOU and BFOU according to IEC 60092-376 Cables with collective screen Type Capacitance, approx. (nF/km) Inductance, approx, (mH/km) Resistance at 20°C, max. (Ohm/km) L/R ratio, (microH/Ohm) Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² 100 100 0,67 0,67 26,3 26,3 12,7 12,7 Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² 110 110 0,63 0,63 12,9 12,9 24,4 24,4 Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² 125 125 0,59 0,59 8,02 8,02 36,8 36,8 Unshielded 16 and 24 pair 2,5 mm² Unshielded 16 triple 2,5 mm² 95 95 0,66 0,66 8,02 8,02 41,1 41,1 Cables with individually screened pair/triples Type Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded pair 2,5 mm² Shielded triple 2,5 mm² Shielded 16 and 24 triple 1,5 mm² Shielded 16 pair 2,5 mm² Subject to change without prior notice Capacitance, approx. (nF/km) 110 110 125 125 145 145 105 110 Inductance, approx, (mH/km) 0,67 0,67 0,63 0,63 0,59 0,59 0,71 0,66 Resistance at 20°C, max. (Ohm/km) 26,3 26,3 12,9 12,9 8,02 8,02 12,9 8,02 L/R ratio, (microH/Ohm) 12,7 12,7 24,4 24,4 36,8 36,8 24,4 41,1 Page 206 of 212 Material properties Polymeric materials used in cables for ships and offshore topside installations For more than 30 years Draka Norsk Kabel has been facing the same challenge : The increasing severe performance criteria demands from our ship and offshore customers. Elastomers are the major part of our cable construction. The insulation, bedding and sheathing have been developed through intensive research and development to meet the offshore and ship industry's specific and stringent requirements. This information is not intended to give you details of the elastomers in use. For correct selection and application of materials our technical representatives will be pleased to provide you with more complete information. EP - rubber (EPDM) EPDM is a hydrocarbon rubber that combines electrical performance suitable for fire resistant offshore cables with mechanical toughness and resistance to ozone, UV light and heat. Its wet electrical properties are unique. Applications : Wire insulation Bedding compounds Flame retardant halogen-free termoset compound (EVA) EVA, ethylene vinyl acetate, is a multi-functional elastomer, which resists the combined deteriorating influences of heat, oil and weather. (In accordance with IEC 60092-360, type SHF2). For offshore applications, EVA can be compounded to produce high quality cable sheathing with low smoke and flame propagation, and with no emission of halogenous acids. Applications : Cable sheathing on offshore oil platforms, ships, hotels and in rooms with expensive equipment, which must not be subjected to corrosion damage. Low smoke , Flame retardant , Halogen-free and Thermoplastic compounds , HFFR. When PVC is not acceptable due to the problems chlorine (halogen) containing materials present in the event of a fire HFFR must be used. (In accordance with IEC 60092-360, type SHF1). Our HFFR materials will not propagate a fire along a cable run, drip or give off black smoke. No acid gases will be released during a fire that can corrode and damage expensive equipment. Applications: Cable sheathing for Rooms with IT equipment High - rise buildings (hotels) Hospitals Telephone exchanges Subway systems, airports and many others. Subject to change without prior notice Page 207 of 212 XLPE – Crosslinked Polyethylene Polyethylene is the most used plastic material. By introducing chemical bonding between the chains in PE we get XLPE, a thermoset type of PE. In cable insulation it is used for the excellent insulation properties , very good mechanical strength , low density and good thermal stability. Applications : Wire insulations Physical and chemical properties of Draka's sheathing compounds for use in offshore topside and shipboard cables Enhanced oil resistant EVA (SHF2) 3-4 NITRILE/ PVC PVC HFFR Arctic Grade Hydraulic Oil Resistant 4 4 (SHF1) 2-3 (SHF2) 3-4 (SHF2) 4 Weathering (O2 -O3 ) 5 4 5 4-3 5 4-5 Heat resistance 4 3 2-3 4 4 4 Low temperature 3 3 2 3 5 3-4 3-4 4 2 0 3-4 3-4 3-4* 4 1 0 3-4* 3-4* Hydraulic oils Sea-water 1 3 1-2 4 1 4 0 3 2 3 5 3-4 Fire resistant 4 3 4 4 4 4 Oxygen Index 4 3 4 4 4 4 Smoke generation 5 2 1 5 4-5 4-5 No CI CI No No No Mechanical properties Hydrocarbons general Hydrocarbons high aromatic (MUD) Halogens 5 - Excellent, 4 - Very good, 3 - Good, 2 - Medium, 1 - Poor, 0 - Not recommended * Drilling MUD is not one chemical, but a mix of different chemicals and each producer have their own composition. The sheathing material could be resistant to the aromatics in the MUD, but be affected by other chemicals like corrosion inhibitors. Each MUD must therefore be tested for compatibility with the cable sheathing. The test method for this MUD test is described in NEK TS 606: 2009 Fourth edition. Subject to change without prior notice Page 208 of 212 SHF1 versus SHF2 The table below addresses only some main characteristics differences. For complete information see IEC 60092-360 Type of material SHF1 Halogen-free Thermoplastic SHF2 Halogen-free Elastomeric or thermosetting material Some main characteristics Mechanical characteristics after immersion in hot oil (IEC 60811-404) No requirements 100 °C for 24 hours: ±40% maximum variation in tensile strength: ±40% maximum variation in elongation at break Hot set test (IEC 60811-507) No requirements 200 °C, 15 min time under load with 20 (N/mm²) mechanical stress: 175% Maximum elongation under load 25% Maximum permanent elongation after cooling Pressure test at high temperature IEC 60811-508) 80 °C, 4-6 h under load depending on cable diameter: 50% Maximum permissible deformation No requirements Heat shock test (IEC 60811-509) 150 °C) 1h duration: No requirements Ozone resistance test IEC 60811-403 (Alternative test method B may be used) Subject to change without prior notice No requirements 25 ± 2°C for 24 h: 275±25) -4 x 10 ozone concentration (in volume) Page 209 of 212 Core colours for cables according to NEK TS 606 Please look at the actual page for each cable type. Instrumentation and communications cable for fixed installation (conductor size from 0,75 mm² and above) such as RFOU, BFOU, RU and BU 250V. Pair: Black -- Light blue Triple: Black -- Light blue - Brown Pairs and triples are identified by numbered tape with printed black numbers. Power and control cables for fixed installation, such as RFOU, BFOU, RU and BU 0,6/1kV One core: Two cores: Two cores + earth Three cores: Three cores + earth Four cores: Four cores + earth Five cores Above 5-cores : Black Blue – Brown Blue – Brown – Yellow/green Brown - Black – Grey Brown - Black – Grey – Yellow/green Blue - Brown - Black– Grey Blue - Brown - Black– Grey – Yellow/green Blue - Brown - Black– Grey - Black Black numbers on white base. Colours are in accordance with IEC 60445 and Cenelec HD 308S2 Medium Voltage cables for fixed installation, RFOU 1-core : Off-white insulation + black semi-conductive layer. 3-cores : Off-white insulation + black semi-conductive layer identified by Brown - Black - Grey threads under and over the metallic screen on each individual core. Separate earth conductor (if any): Yellow/green Subject to change without prior notice Page 210 of 212 Drum capacity in meters Free space mm. Drum No: 30 30 30 30 30 30 30 40 50 60 60 60 60 70 70 80 90 100 Free space mm R5 R6 R6T R8 R9 R10 R10A R11 R12 R14 R14A R16 R16A R18 R20 R22 R24 R26 Drum No: Overall cable diam.mm Overall cable diam.mm 10 360 720 850 1470 12 250 500 565 1020 1440 14 185 370 425 770 1105 1520 16 280 10 12 550 825 1160 18 450 620 920 20 375 14 1335 570 16 1010 1510 18 510 745 460 850 1100 1565 1065 22 420 615 380 700 885 1925 880 1645 20 24 340 515 320 580 830 1075 740 1380 870 26 440 270 470 685 905 630 1175 740 1485 28 380 235 440 555 745 540 985 635 1255 30 330 22 24 26 1685 28 205 345 525 705 470 930 555 1045 1375 32 180 330 410 560 415 755 490 980 1300 1565 30 32 34 160 395 545 370 735 430 825 1105 1350 34 36 140 370 420 330 580 385 765 1035 1265 38 130 285 405 295 560 345 630 860 1070 1570 40 115 36 38 390 265 445 310 605 830 1035 1355 2060 40 42 300 240 430 285 485 640 820 1255 1870 42 44 285 220 410 260 460 620 790 1065 1700 44 46 200 390 235 440 595 760 1025 1560 46 48 185 315 215 445 595 635 895 1430 48 50 170 300 200 340 460 605 855 1320 50 52 160 285 185 320 440 580 820 1220 52 54 145 285 170 320 420 550 665 1130 54 56 135 160 300 420 445 670 1050 56 58 125 150 300 420 425 635 980 58 60 120 140 215 400 425 640 915 60 62 130 215 310 400 500 860 62 64 120 290 405 500 805 64 66 115 290 380 475 755 66 68 110 275 295 475 715 68 70 100 275 275 445 675 70 72 255 275 360 635 72 74 260 275 360 600 74 76 255 335 570 76 78 255 335 540 78 Subject to change without prior notice Page 211 of 212 Code designation for cables A cable code of 2 - 4 letters is used to descriebe the construction. Additional abbrevation for instrumentation cables: Collective screen = (c) Individual pair or triple screen = (i) The interpretation ( per letter) can be read from the table below: 1st. letter: Insulation 2nd. letter Bedding / inner sheath 3rd. letter Armouring / screen 4th. letter Outer sheath A Fibre, tight cladded A Aluminium (optional with corrosion protection) A Strength member yarn A Yarn + bitumen B Fire resistant tape + insulation (Halogen-free) B Corrogated aluminium (o.w.c.p.) B Steel tapes, 2 off B Hydrocarbon resistant sehath C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene CPE C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene CPE C Galvanized steel wire braid C Polychloroprene (Neoprene) PCP, or chlorinated polyethylene CPE D Impregnated paper Drip free D Aluminium + Plastics D Oil filled cable reinforcement (Longitudinal / Transverse) D E Polyethylene - PE Polypropylene - PP E Polyethylene - PE Polypropylene - PP E Oil filled cable reinforcement (Transverse only) E Polyethylene - PE Polypropylene - PP F PE or PP + filling compound F Bedding or taping (Halogen-free) F Flat steel wire armour F Semi-conducting PE G Polyamid - PA G G PE + PA H Chlorosulphonated polyethylene - CSP H Chlorosulphonated polyethylene - CSP H Steel tape + steel wires H Chlorosulphonated polyethylene - CSP I Thermoplastic compound (Halogen-free) I Thermoplastic compound (Halogen-free) I Steel tapes, 4 off I Thermoplastic compound (Halogen-free) K Paper K Lead K Steel wire, plastics or rubber coated K Lead L Air + plastics (Coaxial cable) L Aluminium laminate + plastics sheath L Aluminium (laminated to outer jacket) L M Expanded PE or PP + filling compound M Polyester M N Impregnated paper N Polyurethane N O Impregnated paper, oilfilled cable O Lead + Plastics P Polyvinylchloride - PVC P Polyvinylchloride - PVC Q Fibre in loose tube Q R Ethylenepropylene rubber EPR R S Silicone rubber T G M Polyester Steel (laminated to outer jacket) N Polyurethane O Copper wire braid (Tinned or bare) O P Phosphorbronze wire braid P Q Steel wires + counter steel tape (optional) Q Ethylenepropylene rubber EPR R Steel wires (round) + filling compound R Ethylenepropylene rubber - EPR S Bedding or taping + concentric conductor S Concentric conductor (Screen) S Silicone rubber Cross-linked polyethylene XLPE T PE + aluminium wire + steel tape T T Cross-linked polyethylene XLPE U Halogen-free thermoset compound EMA or EVA U Halogen-free thermoset compound EMA or EVA U U Halogen-free thermoset compound EMA or EVA V Fibre, slotted core V Aluminium screen V Double wire armour (two layers) V Other halogen-free thermoset materials W Other materials W Other materials W Catenary wire W Other materials X No insulation X No bedding or equivalent X No armour X No sheath Y Screen Y Y Z Flour plastics Z Z Y Z Flour plastics PTFE / FEP Subject to change without prior notice Polyvinylchloride - PVC Flour plastics Page 212 of 212 Draka Norsk Kabel AS VISITING ADDRESS Kjerraten 16 3013 DRAMMEN NORWAY Tel: Fax: +47 32 24 90 00 +47 32 24 91 45 www.prysmiangroup.no POSTAL ADDRESS Postboks 369 Bragernes 3001 DRAMMEN NORWAY