schedule of rate - Latest Documents

advertisement
“Indoor and Outdoor signalling works consisting of trenching, cable laying, termination of cables, casting of foundation, erection of signals,
apparatus cases, junction boxes, relay and power supply, wiring of relays in huts/ location boxes, testing and commissioning of track circuits,
point machines, signals, continuous track circuiting, circuit alteration in relay rooms to commission automatic block working between Juhi
and Panki on north and south lines and suitable alteration in Kanpur cabins area”.
S.No. Description of Items
1
1.1
2
2.1
2.2
Unit
Qty.
Rates
Job
2
61215.0
Total
Inspection by
Designing & Drawing
Preparation of cable route plan, Cable core chart, Power supply arrangement, Cable termination
chart in relay room and location boxes, Location wiring plan, Cable insulation chart and register,
Battery history card, Lamp register, Fuse analysis, Equipment disposition plan, Track circuit
plan, Terminal and Contact analysis chart for relay huts, location boxes, Signal locations,
locations of fixing of location boxes Outdoor circuits and other outdoor diagram and obtaining
approval of the engineer as per following: (i) Supply of 6 copies of completion set of superior quality paper, laminated, properly bound in
steel clip jaw with cushioned cover.
(ii) Software back up of complete set in the form of CDs.
(iii) One complete set of tracing.
(iv) Design through CAD.
(v) Drawing in size A-3 and plan in bigger size.
122430.0
Consignee
Trenching, Cable Laying, Cable Termination, Earthnig, Location Boxes Items
11000
30.0
330000.0
80
68.0
5440.0
P. Mtr.
600
2508.0
1504800.0
Supply of Double Walled Corrugated Pipes (Elect.REX/Tele.REX or similar) for under ground
P. Mtr.
communication/ signal cable protection 120 mm Outer Dia., 103.5 mm Inner Dia. in 6 Meters
straight length as per British Std. No. BSEN 50086-1& BSEN 50086-2,4 & BIS draft Spec. DOC
HQ LTD 14 (5071)& ETD (5072) to Spec. IS 14930 part II. NOTE:- One coupler for joining
shall be supplied with each 6 mtrs. length. INSPECTION BY RITES OR Authorised
representative of Railways.
Supply and fixing of G.I. pipe 100 mm dia, 3mm thick B Class (as per sp.No IS 1239PT.1/1990 ) P. Mtr.
perforated at a distance of 20 cm or less of required length at culverts/bridges, suitably concreted
at both ends as per drg. No. (NR/S&T/CON/1. 4/97) to be filled with chattered compound. G.I.
clamps of M.S. flats, bolts and nut to be supplied by the contractor.
800
182.0
145600.0
150
605.0
90750.0
75
200
15000.0
53000
2.5
132500.0
88000
2.0
176000.0
141.5
21225.0
904.2
9042.0
Excavating and refilling of trench after laying the cables to the level of ground with rammed
P. Mtr.
earth as per Drg.. No. (NR/S&T/CON/1. 1/97) so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr.
Deep on both side of the station alongside the track. It shall conform to the safe distance as per
signalling and cable plan in all type of soil. It also includes clearance of routes of trees & bushes.
Lesser depth due to site condition shall be paid proportionately (Cables will be supplied by
Railways)
Excavation and refilling of trench .3 mtr wide and 1.0 mtr deep from bottom of rail sleepers
P/Mtr
across the track. Track fittings including ballast etc to be restored to original after finishing the
work Earth should be well rammed so as not to form a drain. Prices to be quoted for 1 mtr deep
trench. Payment will be made in proportion to trench depth. During laying and trenching all
precautions will be taken by contractor for safety of trains.This include laying of DWC pipe also.
Consignee
Consignee
2.3
Horizontal boring under railway track/ road for laying 125 mm dia.,laying of DWC (Double
Walled Corrugated) pipes at the depth of 1.4 meter to 2.1 meter from formation level (Level of
earth below ballast) as per drawing and directed by engineer-in-charge by trenchless technology
excluding the cost of DWC pipes. Size of the bore at any location for laying DWC pipes will be
decided by Engineer in charge.
(a) The cost shall include horizontal boring through any intermediate obstruction, either natural
or man made or any bouldry strata.
(b) The rate is inclusive of all the materials, equipments and labour required for doing trenchless
horizontal boring under the railway track, Nothing extra shall be admissible on any account then
the rates quoted above.
(c) The pipes are to be laid under railway track/ road. All necessary arrangements are to be
provided and all precautions are to be taken, so that bore coming out at other end is not deviated
from the horizontal level line by more than 250 mm in horizontal or vertical direction.
(d) The rates shall be inclusive of detection and protection of underground utilities encountered
during boring.
(e) The payment for boring shall be made only when DWC pipes provided in item No. 2.4 are
laid in the bore.
2.4
2.5
2.6
2.7
2.8
Consignee
RITES or Authorised Representative of Railways will carry out the inspection. No payment to be
made for only supply. All payments to be made after laying and to the extent of pipe used in
laying
Supply and laying of RCC Pipe including split Pipe where required 150 mm dia,2 meters Long Per Mtr
with collar(to specification No-IS-460/1974) in the trench across the track/ road and level xing
gates etc as per Drg. No NR/S&T/CON/1.3.97
RITES or Authorised Representative of Railways will carry out the inspection. No payment to be
made for only supply. All payments to be made after laying and to the extent of pipe used in
laying
Laying of Signalling / Telecom / Power cables of different sizes as per drg. No.(NR/S&T/CON/1. P. Mtr.
1/97) and as per cable route plan approved by Railways and meggering of cable before and after
its laying of all type of outdoor cables. (Bunch of the cable in the trench to be secured by a u
clamp made by released rod from the cable drum at a distance as per instruction of engg at site)
Supply and laying of second class bricks in the trench as per Drg No. (NR/S&T//Con//1.1/97)
and instruction of Engr.at site.
Per
Brick
Rites
Consignee
Consignee
Fabrication, supply and fixing of cable marker of 1: 3: 6 concrete as per Drg. No. NR / S&T /
Per
150
CON /1.5.97. The marker shall be fixed at various places of cable route as per instructions of
Marker
Engr. at site.
Nos.
2.10 Supply and provision of straight through M-seal joint kit for 30 Core x 1.5 Sq. mm signalling
10
cables.
P. Core 16000
2.11 Termination of all the cores of all types of outdoor cables after its laying on both ends under
supervision of Railway representative. This also includes preparation of test report for core to
core and core to earth on prescribed Performa for each core of the cable separately. This also
includes dressing and lacing of cable on both ends. Performa for testing and material for lacing to
be supplied by the contractor.
2.9
Consignee
Consignee
Consignee
7.0
112000.0
2.12 Supply of terminal block M-6 (ARA terminal as per IRS spec. No. IRS-S-75/91 (latest) and IRS
Drg. No. SA-23741/A. Alt.4.
Nos.
16000
46.0
736000.0
2.13 Casting, concreting and curing of foundation and erection of App. Cases (Single) as per drg. No.
NR / S&T / CON / 2.7. 97. All materials such as cement, sand, aggregate and anchor bolts shall
be supplied by the contractor. Contractor is required to execute all type of repair works of
foundations if required while inserting the cable for termination.
2.14 Casting, concreting and curing of foundation and erection of half app. cases as per
Drg.No.NR/S&T/CON/2. 8/97. All material such as cement, sand, aggregate and anchor bolt
shall be supplied by contractor. Contractor is required to execute all type of repair works of
foundations if required while inserting the cable for termination.
Nos.
60
3351.0
201060.0
Nos.
20
2792.0
55840.0
2.15 Supply of apparatus case steel single with ‘E’ type lock and Key ward No. 42, as per sketch No.
RE / S & T / ALD / SK / 219 / 82 with Alt ‘A’ & 221 / 82 with Alt. ‘B’. The key and handle
should be at the rate of one each per 4 Nos. apparatus case.
2.16 Supply of apparatus case half steel RE Type fitted with ‘E’ type lock and key ward No. 42 and
handle single as per Drg. No. Sketch No. RE / S & T / AID / SK / 220 / 82 with Alt ‘B’ & 221 /
82 with Alt. ‘B’.
2.17 Provision, preparation & fixing of bakelite Hylum sheet 910x600x6 mm and teak wooden shelf
900x450x25mm duly fixed by angle iron piece of different size inside the Apparatus Case. Hylum
board shall be fixed on an angle iron frame of 25mm x 25mm x 3mm. Angle iron frame will be
fixed in location boxes secured by nuts and bolts. This includes wiring, fixing, of fuses, ARA
terminals, shelf type / Q series relays and other type of relays on square bars and jamming of
cables with 2 inch thick Sal wood plank provided at the bottom. This will include opening,
twisting and jamming armour of each cable in the hole drilled separately for each cable through
the sal wood plank and all cable entry points on location boxes, location huts, Junction Boxes,
relay room / battery room to be closed with suitable masonary works covered with sand and
plastering with cement from top. This includes provision of lugs, eye joints, eyelets for
termination of power cable.( size of hylum sheet to be adjusted in battery box if required)
Nos.
60
9330.0
559800.0
Nos.
20
7096.0
141920.0
RDSO
Consignee
Consignee
Rites
Rites
Writing description for terminals, drawing of circuits, inside Apparatus Case. Painting from out
side as well inside with red oxide and aluminium paint is covered separately. Size of lettering
will be 10mm or as per instructions of Engineer at site.
All materials including teak wood shelf, hylum board, sal wood plank, angle iron square bar,
flexible 16/0.20 or 3/. 029 wire and wiring like thimble, material for termination of power cables
etc. as per the IRS spec, non-deteriorating type HRC fuses and bases, nuts and bolts and other
items shall be supplied by the contractor.
(a) Apparatus Case single with hylum only not involving wiring of relays.(shelf may be replaced
by hylum sheet)
Nos.
30
3075.4
92262.0
(b) Apparatus case single involving wiring of relays
(c) Apparatus Case single used as Battery box.
2.18 Provision, preparation & fixing of bakelite Hylum sheet 4500x300x6 mm and teak wooden shelf
450x300x25mm duly fixed by angle iron piece of different size inside the Apparatus Case. Hylum
board shall be fixed on an angle iron frame of 25mm x 25mm x 3mm. Angle iron frame will be
fixed in location boxes secured by nuts and bolts. This includes wiring, fixing, of fuses, ARA
terminals, shelf type / Q series relays and other type of relays on square bars and jamming of
cables with 2 inch thick Sal wood plank provided at the bottom. This will include opening,
twisting and jamming armour of each cable in the hole drilled separately for each cable through
the sal wood plank and all cable entry points on location boxes, location huts, Junction Boxes,
relay room / battery room to be closed with suitable masonary works covered with sand and
plastering with cement from top. This includes provision of lugs, eye joints, eyelets for
termination of power cable.( size of hylum sheet to be adjusted in battery box if required)
Nos.
Nos.
20
10
3048.5
2636.1
60970.0
26361.0
(a) Apparatus Case half with hylum only not involving wiring of relays.(shelf may be replaced
by hylum sheet)
Nos.
3
1575.0
4725.0
(b) Apparatus case half involving wiring of relays
(c) Apparatus Case half used as Battery box.
Nos.
Nos.
3
14
2000.0
1365.0
6000.0
19110.0
Nos.
40
1779.0
71160.0
Nos.
Nos.
40
40
2382.0
869.0
95280.0
34760.0
Consignee
Consignee
Consignee
Writing description for terminals, drawing of circuits, inside Apparatus Case. Painting from out
side as well inside with red oxide and aluminium paint is covered separately. Size of lettering
will be 10mm or as per instructions of Engineer at site.
All materials including teak wood shelf, hylum board, sal wood plank, angle iron square bar,
flexible 16/0.20 or 3/. 029 wire and wiring like thimble, material for termination of power cables
etc. as per the IRS spec, non-deteriorating type HRC fuses and bases, nuts and bolts and other
items shall be supplied by the contractor.
3
3.1
3.2
3.3
Track Circuits
Supply of Track Feed Battery Charger 110 - 70 V / 2 - 4 - 6 Volt DC. As per RDSO Spec No. S89/93
Supply of Choke 'B' Type to suit Spec. No. - IRS - S - 65 / 83 with latest amendments
Supply of Track feed variable resistance (with pheonolic based) 30 Ohms to suit RDSO Drg. no.
SA 20166 / M (Adv) Alt -1.
Consignee
RDSO
RDSO
RDSO
3.4
Supply of QTA2 ,9 ohms 2F.1B along with plug board, retaining clip and connectors to
BRS:939A, BRS:966, IRS: S34 & IRS:S23
Nos.
40
4618.7
184746.0
3.5
Relay AC immune, plug in type, style* 'QSPA1', DC Neutral Line, slow to pick up 24V 8F.4B
contacts, front and back contacts metal to carbon, complete with plug board, retaining clip &
connectors conforming to BRS:933A,IRS S:60, IRS S:34 & IRS S:23 as applicable.
Charging of secondary cells 2V 80 AH as per charging procedure prescribed by the manufacturer
and approved by the Railway. Two number of charged / discharged cycles should take place as
per standard practice. All material battery, grade distilled water will be supplied by contractor.
Nos.
40
3812.0
152480.0
Nos.
155
136.0
21080.0
3.7
Supply of Low maintenance Lead Acid Secondary Cells 2V 80 AH as per Spec. RDSO IRS: S88/93 with latest amendments.
Nos.
155
1347.0
208785.0
3.8
Installation of DC track circuits in RE area as per Standard Practice. This will include following:
-(a) Jumpering from rail to rail or to track lead junction box including polarity jumpers/cables in
case of point track circuit as per drg. No. – NR / S&T / CON / 3.1.97 and as per insulation
diagram. This includes terminating the jumpers in the TL JB and fixing the jumper on the
sleeper as per instructions of Engr. at site. Fitting of GI pipe and laying of jumper cables through
the pipe. One TL JBs to be provided extra for each polarity jumper/cable. All materials including
G.I. pipe, Channel pins, Bond wires are to be supplied by the contractor.
(b) Fixing of insulated block joints complete with provision of skimmed fishplate. Unskimmed
fishplates shall be supplied by the Railways but skimming to be done by contractor.
Nos.
40
6853.8
274152.0
3.6
Consignee
Consignee
RDSO
RDSO
RDSO
(c) Fixing of TL JBs as per drg. No. – NR / S&T / CON / 3.2.97 along with concrete foundation
and plastering on both ends i.e. T.F. and TR end. All material for fixing including angle iron
shall be supplied by the contractor. This also includes supply and fixing of fibre glassTL JBs as
per Drg No. TS 8467 along with provision of M-6 terminals as per Drg No. 23745 Alt. 4 TL JB
to be written with track circuit number.
(d) Provision and wiring in the Apparatus Cases of T.F. battery charger, TF resistance 30 Ohm,
track relays & batteries as per the standard practice using NDT fuses and terminals. This include
all wiring materials, fuses, suitable antilittering arrangement for relays etc will be supplied by
contractor.
(e) Commissioning of track circuits as per provisions of Para of IRS spec. S -36/81. This includes
adjustment of track feed resistance, testing with train shunt resistance. This also includes
preparation of track history cards. Track history card should be supplied by the contractor.
(i) Berthing track circuits
4
Signals
Nos.
19
6581.0
125039.0
Nos.
19
4
2004.0
38076.0
Nos.
1318.0
5272.0
Supply of U lock with Key on CLS signal unit/ Shunt signal unit.
Nos.
50
113.0
5650.0
Installation, erection and wiring of A marker Signal on the same post below main signal on
offset bracket which also includes fixing of lenses / stencil, lamps and hoods, wiring and
focussing of the Signal Offset brackets. “U” bolt for offset bracket and wire and wiring material
will be supplied by contractor.
Supply of Colour Light Signal Base 140mm dia. base, Signal Pole 4.6/5.2 M long and ladder 4.5
mtr/5.1 mtr, working platform and CLS 2/3/4 aspects unit complete with fittings (with off set if
required) longer hood, ploycarbonate lenses clear Red Green and its fitting, locking with U –
lock etc. as per Spec. No. S-23/88, S-7/92, S-26/64,S-75/91,S-57/2005 with latest amendments
or as applicable.
Nos.
10
554.6
5546.0
Nos.
7
25833.6
180835.2
Nos.
14
24578.3
344096.2
Nos.
12
1236.4
14836.8
Nos.
28
400.0
11200.0
4.10 Supply and fixing of Enamel board of size 900x600x1.6 for automatic start ,end and absolute
block start etc. All material required such as MS angle, nut bolt etc will be supplied by contractor
Nos
10
1750.0
17500.0
4.11 Supply of position light shunt signal unit(with off set) as per RDSO No SA23840
4.12 Supply of 1 way junction type route indicator as per RDSO No. SA23401 and IRS-S-66/84
Nos.
Nos.
2
1
2392.0
11960.0
4784.0
11960.0
4.1
Casting, concreting and curing of foundation for main signal as per Dr. no. NR/S&T/CON/2.
1/97 all material such as anchor bolts, cement, sand aggregate to be supplied by contractor.
4.2
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on
the top or on an off set bracket and fitting ladder and guard to the post at the top. Concreting
ladder base and embedded into the ground with supporting bracket in the middle, blanking of the
ladder for a distance of 1 feet between the height 6’ 9” and 7’ 9” from the rail level by MS angle
and MS sheet 1.6mm thick wherever required. This includes provision of wooden (Sal) cross arm
1 mtr. x 1 mtr. for CLS unit prior to the commissioning or fixing of LED unit & hoods on CLS
unit, wiring the CLS unit & fixing the signal. Elevation & distance of foundation from track
shall be in accordance with Schedule of Dimension for Indian Railways published by Govt. of
India and approved drawings.
All items for the above works except items mentioned in Annexure B2 shall be supplied by the
contractor including but not limited to the following items.
(a) “U” bolt for offset brackets.
(b) Wooden cross arm 1 mtr. x 1 mtr.
(c) MS angle and MS sheet for blanking of ladder.
(d) Wire mesh guard, lock for unit if required, nuts and bolts etc. for the following:
(i) 3/4-aspect colour light signal.
4.3
Supply & fixing of protective screen on signals with or without route indicators by expanded
metal (size 20mm x 60 mm, strand 3.25mm wide and 1.6 mm thick) and earthing the screen of
signal with MS flat 2" x 1/4" using G.I Nut bolts & washer as per RE standard. All materials
required for this work to be supplied by contractor.
(i) 3/4 Aspect Signals
4.4
4.5
4.6
Consignee
4 aspect as per drg no. 23003 a/m
4.7
4.8
4.9
5
Supply of Colour Light Signal Base 140mm dia. base, Signal Pole 3.6 M long and ladder 3.5 mtr,
working platform and CLS 2/3/4 aspects unit complete with fittings (with off set if required)
longer hood, locking with U – lock etc. as per Spec. No. S-23/88, S-7/92, S-26/64,S-75/91,S57/2005 with latest amendments or as applicable.
© 4 Aspect as per drg no. 23003 a/m
Supply of A marker Signal Colour Light type with white lense, lamp holder and lock Drg. No. S2748 / M. Spec. No. IRS – S. 23 / 88.
Supply and fixing of Enamel P / G / C/A/Sig No. plate marker with complete fitting as per Drg.
No. NR / S&T dt. 06.02.97. All material required for the job such as MS angle, nuts and bolts,
paint and painting material will be supplied by the contractor.
Consignee
Rites
Rites
Rites
Consignee
Consignee
Consignee
Consignee
Power Supply Arrangement
5.1
Supply of Low maintenance Lead Acid Secondary Cells 2V, 120 AH as per Spec. RDSO IRS: S88/93 with latest amendments.
Nos
39
1177.0
45903.0
5.2
Charging of secondary cells of 120 AH as per charging procedure prescribed by the manufacturer
and approved by the Railway. Two number of charged / discharged cycles should take place as
per standard practice. All material battery, grade distilled water will be supplied by contractor.
Sets
39
203.9
7952.1
5.3
Charging of 200 AH secondary batteries (with contractor own charging equipment) as per
Per Cell
standard procedure .All the charging materials i.e. sulphuric acid confirming to latest
specification will be supplied the contractor. This also includes installation of secondary
batteries, their interconnections and writing work as per direction of Engineer’s representative at
site.
26
339.8
8834.8
5.4
Supply of low maintenance cells of 2 volt 200 AH as per IRS Sepc 88/93
Nos.
26
2685.3
69817.8
5.5
Supply of transformer 230 volt AC/110 v AC 1.0 KVA as per IRS S-72/88
Nos.
9
8625.0
77625.0
5.6
Supply of Transformer 110/230V AC 2KVA following IRS S-72/87
Nos
3
16100.0
48300.0
5.7
Supply of Transformer 110/230V AC 1KVA following IRS S-72/88
Nos.
3
8625.0
25875.0
5.8
Supply of ferro resonant 1KVA stabilizer as per IRS Sec No.74/89 with latest amendments
Nos.
3
20000.0
60000.0
RDSO
RDSO
RDSO
RDSO
RDSO
RDSO
5.9
Fabrication, supply and fixing of battery shelves. Shelves are required to be fabricated with MS angle of
size 50 x 50 x 6 mm in tier like steps and Sal wood battens of size 75x50 mm. Three battens at spacing of
25 mm each shall be used in each shelf and shall be supported by angle irons at a distance of 1 Meter or
less and on both the ends. The angle iron shall be grouted vertically in the floor 250 mm and horizontally
150 mm inside the wall. Angles and planks are required to be painted with anti corrosive paints. (All
materials to be supplied by the contractor) .Size of Shelve may vary from Relay hut to Relay hut and same
be decided by engineer's representative.
Per Meter
of Shelf
25
1076.0
26900.0
5.10
Installation of battery charger, transformer on sapwood rack 1& 1/2 thick of sufficient width and length to
accommodate battery charger etc. and fixed on angle irons (40 x 40 x6) mm grouted horizontal, 150 mm
inside the wall and 250 mm vertically in the floor at distance on 01 Meter or less and connecting the same
to input supply through 32A indicator switch. The lead shall be properly clipped. Indication switch required
for the provision of racks to be supplied by the contractor.
Per
Charger /
Transfor
mer/stabil
izer/invert
er etc.
27
1853.0
50031.0
5.11
Supply of battery chargers
a)220/24V DC /20A as per IRS No.S-86/92 with latest amend
Nos
7
28970.0
202790.0
2
28970.0
57940.0
280
188.3
52724.0
Consignee
6
6.1
b)110/24V DC/20A as per IRS No.S-86/92 with latest amend
Nos
Relays,Relay Wiring etc
Complete wiring of Tag blocks, ECR’s, UECR's, GKT Relays and other equipment including dressing ,
Per relay/
bunching and threading of signalling equipments e.g. Relays, ECR's, point contractor unit, transformers and Equipmen
fuse etc. in the relay hut/ relay room including wiring from batteries installed in the battery room. Nails,
t
clips, screws, ribets, MS angles/ flats required to be fabricated ladders, dressing thread to be supplied by
the contractor. All wiring materials including wires will be supplied by the contractor. NOTE:
Equipments will includes battery chargers, transformers, fuses, relays and contractor unit etc.
6.2
Supply of cartridge fuse block made of PBT as RDSO Drg No. SA 3748 Alt 4 and Spec. No. IRS: S-78/92
with latest amendment. Fuse Block should be suitable for round head type voltage fuses.
Nos.
250
104.0
26000.0
6.3
Supply of Non Deteriorating type low voltage cartridge fuse rated current 2 Amp. /4 amp./10 Amp round
head type as per Spec. No. IRS/S/78/92.
Nos.
250
47.0
11750.0
6.4
Supply of Relay DC Miniature, Plug-in type, Neutral Line, Tractive Armature 24VDC 8F-8B contracts,
front and back contact metal to carbon complete with plug board, retaining clips & connectors, BRS 930A,
IRS S-34, IRS-S-23 (As applicable) type QN1.
Nos.
100
2422.7
242270.0
6.5
Supply of Relay AC Immunised, DC Miniature, Plug-in type, neutral line, tractive armature 24V DC,
12F/4B contracts front and back contact metal to carbon complete with plug board retaining clips and
connectors BRS 930A, IRS-S-34, IRS-S-23 (As applicable) type QNA1.
Nos.
140
2485.4
347956.0
6.6
Fabrication, supply & fixing of cable termination board (as per Drg. No. NR / S&T / CON / 4. 1/97.) made Per MDF
of angle iron size 45mm X 30mm X 5mm along with outer frame made of angle iron size 65mm X 65mm X
7mm duly fitted with ARA terminals, fuses, fuse holders on 6mm bakelite hylum sheet. Cost of fixing of tag
blocks, fuse with fuse holders and termination of cable is covered under separate item. Supply and fixing of
hard wood of size 70cm X 25cm X 4cm in the back for jamming of cables Scaffoldings / cable carriers to be
fabricated and supplied made of angle iron size 35mm X 35mm X 5mm and flat 25mm X 25mm as per
instructions of Engineer at site.
The space between two flats will be 25cm or less as per site requirement. All materials for provision of
scaffoldings / cable carriers to be supplied by the contractor. All the fixing materials like bolts, nuts,
washers, insulators, shoes, angle irons, concrete, ARA terminals 25mm centre / Terminal strips etc. will
also be supplied by the contractor. This includes cleaning, priming, painting and writing by ISI mark paints.
7
12603.0
88221.0
RDSO
RDSO
RDSO
RDSO
RDSO
RDSO
Consignee
7
Circuits
67260.0
470820.0
Design and supply of detailed signalling circuits including panel diagram(RRI Juhi or
set
7
SSI,Electromechanical cabins, relay huts etc), route section plan, selection table,fuse and negative tag.
Analysis, contact analysis, relay rack arrangement and wire count sheet etc in A3 size. Completion circuit
shall be plotted in auto CAD.The contractor shall initially supplt two sets of ciruits duly signed by ckt
designer having substantial experience on design side for making such circuits,complete for approval of
railways. Railways will return one set of circuit to the contractor duly approved with alteration /corrections
if any. the contractor shall incorporate railways alteration/ correction in the original tracings and CDs
without ant deviation and submit two copeis of the modified ckt. original tracings so modified and final CD
complete in all respects along with four sets of final approved ckt(out of which one set shall be supplied in
transparent polythene bags. Only two sheets of circuits shall be palced in one polythene bag each with all
the document in thick plastic folder) shall be submitted to railways in case there are no further alteration suggested by railways. Note: the contractor shall arrange for designing of RSP, Panel diagram, selection table
Consignee
8
8.1
Alteration work
Fabrication and provision of domino type indication cum operating panel of exchangeable unit and cover
plate with tag blocks /terminals. Wire, angle iron etc depicting the yard layout/ with signals, point,track
circuit, operating/emergency push button counters, Sm's key housed in a steel metal cabinet as per
instructions of engineer at site and as per approved panel diagram supplied by railways.This also includes
supply and fixinf acrylic sheet on panel. the panel shall be minimum of 40x30 exchangable units of
dominos of size54mmx35mm normal or as required at site ). LEDs with proper protection to be provided as
per direction of engg, panel shall be supplied with complete soldering. Size of panel should be such so as to
accomodaye one additional line on either side.In case , domino size is smaller the no of exchanagable units
shall increase accordingly so that overall size /area of the panel remain same.This include 20% extra
indication panel bulb/LED, 5% push buttons subject to min of 2 button of each colour to be supplied by
contractor
JUHI RRI/SSI and Q series PI( Limited to alterations in installed panel only)
8.2
Testing and commissioning of PI/RRI/Cabin installation with MACLS system as a whole shall be
carried out by the engineer incharge of the work with the help of representative of the
contractors.All artisan staff and labours required for testing and commisioning shall be provided
by contractor.Testing equipment shall be as multimeter, simulation panel for track circuit,
signal,point,slot etc shall be provided by the contractor at his own cost.Testing shall be carried
out to ensure compliance of SEM, G&SR,block working manual and adherence to spec of tender.
8.3
Nos
2
14125.0
28250.0
a)RRI/SSI
Nos
1
55787.3
55787.3
b)Electromechanical and mechanical installation like Panki and other concerned cabins/Relay
hut
Nos
6
6494.8
38968.8
Days
20
8000.0
160000.0
Nos
5
647.5
3237.5
Supervision of wiring alteration by expert in RRI or SSI.The supervision shall be arranged by
engaging OEM. Supervision shall be provided from the day work in RRI/SSI relay room is
started.
8.4 Supply, preparation, fixing and wiring and soldering of tag blocks on cable termination
rack/relay rack/block rack/HB rack as per drawing no NR/S&T/con/4.2/97. All fixing material
like flats, bolts ,nuts ,washers etc will be supplied by the contractor.
(i) 200 way tag block(
for new tag blocks only)
9
Telecom works
20
3377.7
67554.0
Supply and installation of RTSF-3 as per RDSO modifiaction for emergency
Nos
/derivation/termination joint with VF Tx on 6 Quad cable
Nos
9.3 Supply of VF Transformer 1120:470
Nos
9.4 Supply of EMC socket box
Nos
9.5 Fabrication and fixing of EC socket assembly complete and fabricated assembly
Nos
9.6 Supply of paint and painting of EMC socket
LS
9.7 Painting of telephone mark with arrow
10 Miscellaneous Items
Nos.
10.1 Fabrication of Aluminium Channel (1" x 1") Chamfered Sun-mica Sheet of Teak Wood Frame
and size 4' x 2' x 1" and Supply thereof for painted cabin yard diagram / SM's station layout with
stands and fixing the same on the wall / table. The yard diagram/block section shall be painted as
per SWR diagram and each track circuit portion should be provided with two holes of 10mm dia
to hold the LED assembly including of all supply.
P/Cum
10.2 Earth work for excavation and refilling around location boxes and signals etc. where necessary,
including 50 Mtr. Lead and 1.5 lift. The lead is to be measured from centre of gravity of location
to the centre of filling and lift from main ground level. The earthwork should be well rammed
including breaking of clods, levelling and dressing etc. as per instructions of Engineer at site.
20
3249.7
64994.0
40
40
40
40
1
512.0
382.2
949.3
294.8
1600.0
20479.2
15287.6
37971.6
11792.8
1600.0
3
2981.3
8943.9
15
62.8
942.0
P/Cum
10.3 Concreting unscheduled items in concrete of 1: 3: 6 ratio in cement, coarse, sand and aggregate
25mm at different places in the yard and plastering top in fine plaster of 1: 4 cement to sand
ratio. It includes the excavation of earth also as required at site and as per instruction of Site Incharge. The volume in cubic metres shall include the volume occupied by any CI foundation,
Trestle, MS angle or flat or GI pipe required to be embedded in the casting. Cement, coarse sand
and aggregate 25 mm are to be supplied by the contractor.
Nos.
10.4 Supply and fitting of ‘E’ type lock with accessories in relay room / battery room / location boxes.
All material required for the job such as ‘E’ type lock, MS angle nut and bolts etc. will be
supplied by the contractor as per RDSO Drg. No. SA-3376, 3377 & IRS-S-30/64.
Job
10.5 Filling of cable pits inside the apparatus cases, location boxes and in relay room etc. with sand
and plastering with cement and sand ratio of 1:4. All materials to be supplied by contractor.
Nos.
10.6 Supply & installation of earth electrode as per Standard Practice. The item includes digging of
pit in earth, 3 meters and fixing earth electrodes pipes. Casting of cement concrete enclosures as
per Drg. No. (NR/S&T/CON. /6.3 /97.) the soil treatment shall be done as per Standard Practice.
The item includes provision of MS flat of size 35x6mm2 , wires and soldering of lead wires. The
other end of MS flat to be connected by bolt/ soldering to the block Instrument, cable sheath of
power equipment, Apparatus Case, relays racks,signals other equipments as per the instruction of
Engr.at site and as mentioned in IRSEM. Complete material such as earth electrode as per
Drg.No. (NR/ S&T / CON. /6.4/97) cement wiring material soldering material to be supplied by
contractor.
10.7 Supply and installation of Portable Pre-fabricated, Pre- wired structure of 2 rooms each having an Nos
inner dimension of 3 x 3 x 3 mtr. made of Polyurethane foam sandwich panels.
15
3061.8
45926.4
5
539.8
2699.0
2
340.7
681.4
100
1544.0
154400.0
1
498000.0
498000.0
9.1
Supply and installation of thermoshrink jointing kit for 4/6 Quad cable for derivation joint
Nos.
Consignee
9.2
Consignee
Consignee
Consignee
10.8 Installation and complete wiring of indication operating panel. This includes complete supply
and provision of indoor cable and wires of 1x1mm,1x0.6,3/0.737mm,16/0.20mm flexible
40x0.6mm,40x1mm,60x0.6mm,60x1mm dia cu conductor as confirming to latest IRS
secification, IRSEM provision and instructions of engg at site .this includes provision of panel
tag blocks,wiring from panel tag blocks to relay racks,CT rack in the relay room including
provision of terminal in the panel and termination in the panel. fused bulbs/LEDs shall be
replace during testing period 10% of the bulbs /buttons, LEDs of each colour shall be given as
spare after commisioning. Installation will also include minute civil works.Cable from panel to
relay rack will be taken in GI pipe under ground for which masonary work if required will be
done by contractor. Note: wherever panel/indication room and relay room are at a distance and
outdoor underground signalling cable is to be laid outdoor sig cable will be supplied by railways
and the work of trenching and laying etc shall be covered separately under the item of cable
trenching and laying etc
10.9 Supply of electrically operated Lifting barrier assembly each consisting of 2 nos of electrcally
operated lifiting barriers, 2 Pedastal, 8 band circuit controller with limit switch, hand crank, 2
electric motor 110 V AC 0.5 HP without centrifugal switch, 2 aluminium boom in 4 sections of 8
feet long each ,with 2 stop board , boomlight boxes , CI counter weight and 2 no of boom support
for resting boom and boom locking assmbly along with contractor units , gate controlpanel,
indication panel on sheet meta; fabricated box with switches and buttons to operate the gate as
per IRS S41/70 except (a) motro current is max. 5 Amps. for 0.5 HP motor and motor confirms
to IS-996 (b) Elmex terminal to be used instead of M-5 terminals (C) Circuit controller should
have CAM operated Siemens limit switches instead of wiping type contrats ,Crank handle
arrangment will be as per Railways requirment. The movement of the boom over 85 degree to be
restricted mechanically
10.10 Installation, testing and commissioning of electrically operated lifting barrier complete with
casting of cement concrete foundation for pedestal and boom rest post.This icludes cabling and
power supply connection wiring with outdoor works etc.
Nos
5
2669.0
13345.0
Nos
1
203942.0
203942.0
Set
1.00
22777.0
22777.0
10.11 Supply of LC gate monitor with multiline point to point telephone communication
equipment(one set consist of two communication equipment)
10.12 Leading, Loading and unloading of signalling material from any station to GMC/JHS etc. All
expenses to be borne by Contractor
Set
1.00
35000.0
35000.0
4.7
705000.0
11 T&P
11.1 Supply of auto range Digital Insulation Tester (Meggar) with Ni Cd rechargeable cell as per
Spec. As below voltage 500 volt DC, Insulation range 200/2000 Mega Ohms auto range,
resolution 0.1 Mega ohms accuracy +/- 1%, make Electron Devices Model No. DIT / 500.
Consignee
Consignee
Consignee
Consignee
Consignee
Consignee
RDSO
Consignee
Per
150000
Tonne
Km
Nos.
1
6590.2
6590.2
Consignee
11.2 Supply of portable digital multimeter Philips make model PM-2518 or of Motwani or of similar
Standard make having similar specification as per Engr. instructions.
11.3 Supply of Clip on meter to read AC and DC voltage and current of standard make
Nos.
1
8159.3
8159.3
Nos
8
6500.0
52000.0
11.4 Supply of Annunciator multi way telephone exchange 10 line to RDSO Drg. No. TCA - 3352
(Adv.)
11.5 Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery graded
acid with mounting stand in location boxes.Consignee inspection under manufacturers certificate.
Set
1
4473.4
4473.4
Nos
10
185.7
1857.0
11.6 Supply of Revolving Executive Chair Model DC-9.
Nos.
1
1377.2
1377.2
11.7 Supply of Metal chair with Armrest for Office purpose non-revolving Non-tilting type.
Nos.
6
559.5
3357.0
11.8 Supply of Steel Shelving cabinet adjustable type with locker / Drawer type.
Nos
2
8009.9
16019.8
11.9 Supply of resistors,condensers,diodes,LEDs and Lugs along with bracket and mounting
arrangement as per annex
12 Supply of data logger
12.1 (i) Supply installation testing and commissioning of data logger on CPU along with power supply
unit for 512 input digital and 32 analog input cards as per RDSO spec no.I RDSO/SPN/90/98
and IRS S99/2001 or latest from RDSO approved firm.with suitable CMU rack
LOT
1
25675.0
25675.0
Nos
3
285000.0
855000.0
12.2 (ii)Supply installation,testing and commissioning of Multi port Front End Processor as per
RDSO Spec IRS:S-99/2006
12.3 (iii)Supply ,installation,testing and comissioning of Central Monitoring Unit or Failure analysis
system as per RDSO spec No RDSO/SPN/90/98 and IRS-s-099/2001 or latest with suitable CMU
rack
12.4 (iv)Software to run complete system so as to generate fault/ diagnostic report as per spec
Nos
1
121000.0
121000.0
Nos
1
102200.0
102200.0
Nos
1
25000.0
25000.0
12.5 (v) Dual leased line modem for interlinking of data logger
Nos
6
21000.0
126000.0
12.6 (vi) supply installation, testing and commissioning of failure analysis system as per spec
Nos
1
130000.0
130000.0
12.7 (vii) supply of laptop based work station data input configuration, simulation function testing,
diagnostic and trouble shooting
13 Dismantling
Nos
1
108468.5
108468.5
Consignee
Consignee
Consignee
Consignee
Consignee
Consignee
Consignee
Consignee
RDSO
RDSO
RDSO
Consignee
Consignee
Consignee
Consignee
13.1 Dismantling and releasing of signals, signal posts (Electrical as well as Mechanical complete),
which includes the dismantling of signal fittings. Wheels of sorts, pulleys, pulley stacks, GI pipes
wire run, from cabin to signal posts etc. and staking in the store of SSE/IRPMU/Juhi.
P/Sig.
6
677.8
4066.8
13.2 Dismantling and releasing of Location boxes/Apparatus cases, which include releasing of
terminal and terminal board, relays, batteries, battery charger and other connected fitting.
P/Job
20
326.4
6528.0
13.3 Dismantling and releasing of S&T gears in battery room / relay room. This includes all
equipments and relays, relay racks, termination boards, batteries, battery chargers and angle iron
etc and stacking in the store of SSE/IRPMU/Juhi.
P/Job
1
3978.3
3978.3
13.4 Dismantling and releasing of lifting barrier gate and its complete fittings including carting,
stacking inside the store of SSE/Signal, IRPMU/Juhi.
P/job
1
1441.0
1441.0
GRAND TOTAL
Note:-Tenderer to quote percentage above(+) or below(-) over tender total cost =
12098554
Download