Schedule for the work

advertisement
Schedule for the work: Interlocking of level crossing gate no.12 in Pune-Daund section of Pune Division.
PART- I (Supply portion)
Sr. DESCRIPTION
No.
Indoor Work
Relay Rack Equipments
1
Supply of Relay Rack Assembly complete with
scaffolding, fixtures and accessories including MS
Bars for fixing of relay, plug board, string rods, fuse
strips with bracket, 11 Way Bus Bars with cover
and mounting brackets, runway for cable/wires,
frame, base assembly etc. Siemens type & as per
extant practice on C. Rly. Typical part list as per
Annexure-I and Rack arrangement as per Sketch
no SK-727 and Rack plan as per MTJ/S&T/C/143
enclosed.
2
Supply of Tag Blocks 200 way with cover as per
IRS S 77-91.
3
Supply of Main Cable Termination rack complete
with scaffolding, fixtures & accessories including
square bars for mounting 8-way terminal blocks,
ladder, string rods, frame, base assembly,
imulators, J bolt, nut/bolts & fasteners (backelite
strips) etc. Siemens type & as per extant practice
on C. Rly. Typical part list as per Annexure-II and
rack arrangement shall be as per sketch SK 727
enclosed.
4
Supply of 8-Way Terminal strips, made of PBT,
isolating barrier type as per RDSO SPN No IRS-S75/91 & Drg No 24811 alt 1 with latest amendment
or of latest RDSO Specification.
Indoor Cables & Jumper Wires
Indoor cable, jumper wire conforming to specn No
IRS: S- 76/89 (Amendment 2 or latest) colour code
as per requirement.
5
Supply of Indoor Jumper Wire of various colour as
per Railways standard practice of type ATC 1 x
0.6 mm dia.
6
Supply of Indoor Jumper Wire ATC 1 x 1 mm dia.
7
Supply of Flexible Cable, Single core, multi strand
10 sq mm as per specn IRS 76/89 with latest
amendment (size 104/.35)(for sizes/parameters not
covered by IRS 76/89 relevant clauses of IS 694/
77with latest amendments will be applicable).
8
Supply of Flexible Cable, Single core, multi strand 6
sq mm .with Grey colour as per specn IRS 76/89
with latest amendment (size 85/.3) (for sizes/
parameters not covered by IRS 76/89 relevant
clauses of IS 694/77with latest amendments will be
applicable).
Power Equipments
9
Supply of primary cell SITEL or similar as per IRS:
S95/96.
10 Supply of ELD for measuring non earthed single
phase or three phase AC networks to monitor four
different AC supplies at one time, Reliance
Electrical make or similar. Manufacturer's test and
guarantee certificate to be submitted by the
contractor.
UNIT
QTY
RATE
AMOUNT
Rupees
Rupees
INSP.
AGENCY
Set
1
16578
16578
Consignee
No
6
699
4194
RDSO
Set
1
14582
14582
Consignee
No
20
188
3760
RDSO
Km
3
1282
3846
RDSO
Km
Km
2
0.1
3510
37200
7020
3720
RDSO
RDSO
Km
0.1
27900
2790
RDSO
No
0
158
0
RDSO
Set
1
5500
5500
Consignee
11
12
13
14
15
16
17
18
19
20
21
(a)
(b)
(c)
(d)
22
23
24
25
26
(a)
(b)
27
Supply of ELD suitable to measuring insulation
resistance for circuit working on 12V DC, 24V DC
and 60V DC at one time, Reliance Electrical make
or similar. Manufacturer's test and guarantee
certificate to be submitted by the contractor.
Supply of 12V/70W Solar panel (14 nos. of solar
photovoltaic cell).
Supply of 2V 200AH Low maintenance lead acid cell
as per IRS Specn. S-88/93.
Supply of battery charger self regulating floor
mounting type with 230V AC single phase input and
output 24V DC 30A as per IRS S-86/92.
Inverter Ferro resonant type 24V DC input/ 110V
AC output 500VA as per IRS S-82/92.
Relays, Base plates & Fixtures
Supply of QNA1, 8F-8B, 24VDC along with plug
board, retaining clip and connectors conforming to
BRS: 931A, IRS: S60, IRS: S34 & IRS: S23.
Supply of QNA1, 12F-4B, 24VDC along with plug
board, retaining clip and connectors conforming to
BRS: 931A, IRS: S60, IRS: S34 & IRS: S23.
Supply of Time Element Relay (Clock work type) AG
timer Siemens Make (No RSSK 30/0052) or
equivalent.
Supply of Off aspect ECR for Main Signal Siemens
(No. RSSK 30/0014) or similar (Ref. IRS:S46) with
base plate and other accessories.
Supply of ON aspect ECR for Main Signal Siemens
(No. RSSK 30/0013) or similar (Ref. IRS:S46)
contact configuration or equivalent with base plate
and other accessories.
Accessories
Supply of INDICATIVE TYPE OF FUSE INSERTS.
With holder 1.6 A (System, Rapid or Malnad or
RBCO make or similar).
With holder 0.6 A (System, Rapid or Malnad or
RBCO make or similar)
Without holder 1.6 A (System, Rapid or Malnad or
RBCO make or similar)
Without holder 0.6 A (System, Rapid or Malnad or
RBCO make or similar)
Supply of Solder wire resin core 60/40, 18/20 SWG
of IS 1921/95 (Philco make).
Supply of Lacing thread rolls, black, wax coated
(100 mtrs each) thin & thick in the ratio of 3:4.
Supply of Adhesive tape rolls, PVC (19mmx 10mtrs
steel grip BHOR make or similar).
Supply of Tool kit as per Annexure-III.
Supply of round head type non detoriating type low
voltage cartridge fuse as per Specn No IRS/S/78/92
with latest amendments.
2A Capacity
10A Capacity
Outdoor Work
Signals - Units, Structures & Fixtures
Supply of Main Signal Post 140mm outer dia 4.5
Mtr Length as per Spec No. IRS S 6/81 with latest
amendments.
Set
1
3200
3200
Consignee
No
14
15400
215600
RDSO
No
12
1296
15552
RDSO
No
2
32533
65066
RDSO
No
2
15560
31120
RDSO
No
10
1838
18380
RDSO
No
10
1838
18380
RDSO
No
2
2291
4582
RDSO
No
10
2343
23430
RDSO
No
0
2343
0
RDSO
No
20
39
780
Consignee
No
20
37
740
Consignee
No
20
11
220
Consignee
No
20
11
220
Consignee
Kg
0.75
600
450
Consignee
Roll
5
50
250
Consignee
Roll
8
20
160
Consignee
Set
1
10000
10000
Consignee
No
No
20
20
25
25
500
500
Consignee
Consignee
No
2
3300
6600
RITES
28
29
30
31
32
33
34
35
36
37
38
(a)
(b)
(c)
39
40
41
(i)
(ii)
42
43
Supply of Main Signal Post 140mm outer dia 5.5
Mtr Length as per Spec No. IRS S 6/81 with latest
amendments.
Supply of Cast Iron Main signal surface base
140mm as per Spec No. IRS S 10 and Drg. No.
2011/M with latest amendments, with CLS Ladder
assembly complete for CLS signal 5.5 mtrs long as
per RDSO Drg. No. SA-23156 & signal front staging
complete assembly for CLS unit as per Drg. No.
RST/11413 & signal back staging as per extent C.
Rly. practice.
Supply of Signal No. plates as per Drg. No. RST11393.
Supply of G Board as per RDSO Drg. No. SA 2345556 RST-11445 & SA 23476-77 as applicable.
Supply of Goods warning Board as per RDSO Drg.
No. SA 2380 (Adv). Paint and retro reflective
arrangement as per Drg. No. BPL/S&T/M/47.
Supply of Hand Cuff Locks.
Supply of CLS Unit 2 Aspect as per RDSO No.
SA25003/A/M with Holder of PBT for SL 35 Lamps
as per RDSO Drg. No. SA-24831.
Supply of CLS Unit 3 Aspect as per RDSO No.
SA25002/A/M with Holder of PBT for SL 35 Lamps
as per RDSO Drg. No. SA-24831.
Supply of miniature circuit brakers 6A/230V as per
IS 8828/1978.
Supply of miniature circuit brakers 16A/230V Indo
Asian or Indo Kupp make.
Supply of Universal 110V AC/DC LED based Main
Signal
as
per
RDSO
Specification:
RDSO/SPN/153/2002 (or latest Drg.) for CLS signal,
with current regulator and health monitoring alarm,
of Colour:
RED
YELLOW
GREEN
Apparatus case
Supply of Hylam sheet, resin bonded 10mm thick,
grade P3 in standard size of 1.22X1.22 Mtr as per
Spec. No. IS 2036 of 1974.
Supply of ARA Terminal Block as per Drg. No. SA23741 alt 3 & Spec. No. IRS S 75/91 with latest
amendments.
Supply of cartridge fuse block made of PBT as per
RDSO Drg. No. SA-23748 Alt 4 & Spec. No. IRS S
75/91 with latest amendment. Fuse block shall be
suitable for round head type voltage fuses.
2 Amps
10 Amps
Supply of Keys for miniature E Type lock keys of
approved wards as per RDSO Drg. No. SA-3376
with latest amendment.
Supply of Three pin switch & socket 5A ( Anchor
make ).
No
2
3520
7040
RITES
No
4
5946
23784
RITES
No
4
251
1004
Consignee
No
2
275
550
Consignee
No
2
1621
3242
Consignee
No
No
4
0
138
10106
552
0
Consignee
No
0
13946
0
No
2
165
330
Consignee
No
15
93
1395
Consignee
No
No
No
4
6
4
6600
6600
8100
26400
39600
32400
RDSO
RDSO
RDSO
No
6
2555
15330
Consignee
No
150
43
6450
RDSO
No
No
No
15
15
2
75
80
110
1125
1200
220
RDSO
RDSO
RITES
No
8
110
880
Consignee
44
(a)
(b)
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
Supply of Apparatus cases with miniature E Type
Locks without keys as per Spec. No. IRS S 30/64 &
RDSO Drg. No. SA-3376 with latest amendments.
Single case as per Drg. No. WS-8842/A with latest
alteration. The sheet used should be of 10SWG.
Quarter Case as per Drg. No. S&T/C/SK/154. The
sheet used should be of 10SWG.
Supply of Universal lock Navtal 65mm brass with 3
keys each.
Supply of Lamp Holders, two pin, Bakelite type for
location boxes.
Supply of Electric signalling lamps 110V/40Watts
for location lighting.
Supply of earth electrode assemble as per Drg. No.
NGP/S&T/C/308.
Cable Laying
Signalling cable as per IRS : S-63/89 (amendment
5 of 5/2002 or latest).
Supply of armoured unscreened PVC insulated
signalling cable 12X1.5 sqmm (Ref. IRS:S63/89
amendment 5 of 5/2002 or latest).
Supply of armoured unscreened PVC insulated
signalling cable 6X1.5 sqmm (Ref. IRS:S63/89
amendment 5 of 5/2002 or latest).
Supply of Flexible wire single core multistrand
16/0.2mm as per Specn. No. IS 694 of 1977 with
latest amendments (size 85/0.3).
Supply of Fire Retardant Double Walled Corrugated
pipe made up of Polyethylene of Size 103.5 mm
inner dia and 120mm outer dia in 6M straight
length as per British standard No. BSEN 50086-1
and BSEN 50086-2-4 and BIS draft Spec. Doc. No.
ETD 14 (5071) and ETD 14 (5072) along with one
coupler per every 6 meters.
Supply of Hydrometer, Exide make or similar for
measuring specific gravity of Battery Graded acid
with mounting stand in location Boxes. Consignee
inspection under manufacturer certificate.
Supply of G.I bend for cable entry in J.B.
Supply of Gate Phone with Power supply unit.
Supply of Desk type Electronic Magneto Telephone
as per RDSO Spec.No.RDSO/SPN/TL/28/99 or
latest.
Work related with mechanical lifting barrier
Supply of 2 nos of mechanically operated lifting
barrier consisting of 2 pedestal pinion shafts boom,
stay wire, round stop board with reflector, boom
stock stand, boom block set with crank and counter
weight, bell with fringes complete along with
accessories as per Drg. no. SA-7982/M & SA7990/M and boom locking device assembly
complete for mechanically operated lifting barrier.
Supply of 4 Lever GF complete with tappets and
locking tray as per RDSO Drg. no. SA935/M.
Supply of Point rodding solid 32mm dia. 5500mm
(18'-00) length as per RDSO Drg. No. S-3635 Alt-1,
SA-3548.
Supply of CI foundation A type as per IRS S3529/M.
No
4
5769
23076
Consignee
No
4
3100
12400
Consignee
No
2
120
240
Consignee
No
8
15
120
Consignee
No
10
20
200
Consignee
No
10
596
5960
Consignee
Km
0
82415
0
RDSO
Km
0
57410
0
RDSO
Mtr
750
3
2250
RDSO
Mtr
0
154
0
Consignee
No
1
137
137
Consignee
No
No
No
0
2
2
45
2000
1607
0
4000
3214
Consignee
Consignee
Consignee
Set
1
115500
115500
RITES
No
1
19000
19000
RITES
No
4
875
3500
RITES
No
4
1050
4200
RITES
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
Supply of double wire rope wheel 1 pair 225mm dia
with guides to Drg. No. SA-6101/M,-01A/M.
Supply of Wire Rope GI 7X7-22 SWG.
Supply of Solder grade B.
Supply of Adjustable screw coupling 18" long.
Supply of Adjustable screw coupling 12" long.
Supply of Lug joint 1 1/4"
Supply of Anchor bolts with nuts 12"x 3/4"
Supply of Anchor bolts with nuts 3"x 1"
Supply of Nut & Bolt 1/2" x 2 1/2"
Supply of Nut & Bolt 1/2" x 1 1/2"
Supply of Nut & Bolt 3/4" x 3 1/2"
Supply and fixing of channel plates of size
100x50x1cm duly fitted with angle iron of size
40X40X5 cms for covering channel pits.
Supply of E type lock for GF as per RDSO Drg. No.
SA/3376 of approved wards with keys.
Supply of Circuit controller Lever type 4 way to
Drg. SA-20266.
Supply of Offset solid joint 32mm with coupling end
to Drg. No. SA-6138/M.
Supply of Crank Horizontal 300X300mm to Drg. No.
SA-3414/M.
Supply of Lug Eye 32mm to Drg. SA-3631/M.
Supply of Electronic Solid state flasher Unit for
Road traffic signal 24V DC.
Supply of Dual Tone Warning Bell with 20W horn
and 15W Amplifier Muconny make with operating
voltage 110V AC.
Supply of Road signal made of FRP RST 11540.
Miscellaneous Items
Supply of Cable jointing heat shrinkable type kit
from RDSO approved source RAYCHEM /REPL
make: 12CX1.5.
Supply of cable route marker of FRP material along
with FRP angle. (FRP angle should be extruded by
pultrusion process & not hand moulded) as per
RDSO Spec. No. RDSO/SPN/151/1997 as per
sketch.
Design and Supply of Level crossing Gate cum
indication panel with LED bulb, of 16SWG powder
coated MS sheet of size 39cm X 24cm X 10cm
approx. Consisting of different colour LEDs with
holder to work on 24V DC. Description on the front
panel to be given by Railway engineer.
Supply of 4 X 25 sq. mm Aluminium power cable.
TOTAL AMOUNT (IN RS.) OF PART-I
No
5
600
3000
RITES
Mtr
Kg
No
No
No
No
No
Kg
Kg
Kg
Job
500
10
8
8
4
20
20
10
10
10
1
14
500
300
250
325
55
125
100
100
100
4000
7000
5000
2400
2000
1300
1100
2500
1000
1000
1000
4000
RITES
Consignee
RITES
RITES
RITES
Consignee
Consignee
Consignee
Consignee
Consignee
Consignee
No
1
443
443
RITES
No
5
812
4060
RITES
No
2
182
364
RITES
No
2
630
1260
RITES
No
No
2
2
175
1200
350
2400
RITES
Consignee
No
2
5000
10000
Consignee
No
2
5000
10000
Consignee
No
0
937
0
RDSO
No
60
150
9000
RDSO
No
1
5935
5935
RDSO
Km
0
83700
0
908131.00
PART-II (Execution)
Sr.
DESCRIPTION
No.
INDOOR
Relay Room Equipments
1
Installation of Relay Rack Assembly including IDF pillars
complete
with wall supports, scaffolding, ladders,
runway for cables, Relay/Relay group base plates, fixing
of Tag blocks etc. The work shall be done as per
approved plan, extant practice on C. Railways & the
instructions of Rly engineer at site.
2
Installation of Cable Termination Racks Assembly
complete including wall supports, scaffolding, 8 way/ARA
terminal, 96 way tag block & other necessary accessories
etc. The work shall be done as per approved plan, extant
practice on C. Railways & the instruction of Rly engineer
at site.
3
Termination of cable cores on ARA terminal/or on 8 way
terminals in the cable termination rack. This includes all
associated works of pulling out the cable from under
ground, peeling off insulation, dressing of cable core
supported on sting rod with contractor's own material.
The work shall be done as per instructions of Rly
engineer at site.
Power Equipments
4
Charging of Lead Acid Batteries with contractors own
battery grade sulphuric acid and distilled water with
minimum two charge - discharge cycles, installation of
charged batteries in groups & their connection & wiring.
The work shall be done as per extant practice on C. Rly.
& the instruction of site engineer. The sulphuric acid &
distilled water to be used for charging shall conform to
specification IS 266-1961 & IS 1070-1960 respectively.
(each cell 200AH)
5
Construction of Brick platform for placement of batteries
in power equipment room.
6
Installation, Wiring and testing of solar panel, charging of
lead acid cells, battery chargers and inverters. This
includes power distribution connection to bus bars and
relay racks in the room with contractor's own wiring
materials and fabrication and fixing of AC/DC power
distribution board made on hylam sheet with connections
suitable for 32A. All connectors as per site requirement to
be arranged by contractor and arrangement of fixing of
solar panel with contractors own material as per
instructions of Railway engineer at site.
7
Wiring of Relays, Power supply equipments, ELD, Auto
change over panel, warning bell etc. as per approved
circuits including alteration in the existing location boxes
and installation of program switches. This also includes
fuse wiring, fuse blown off indication, function wiring.
Any material like solder resin core, lacing threads,
adhesive tapes, resistances, condensers.
Accessories
8
Lettering & Numbering of Junction boxes, Apparatus
cases, etc.(each function item to be taken as one unit)
with Contractors on supply of paint.
UNIT
QTY
RATE
AMOUNT
Rupees
Rupees
No
1
710
710
No
1
608
608
Per Rack
1
500
500
Per 100
AH
77
200
15400
No
1
2200
2200
Lot
1
2000
2000
Job
1
3000
3000
No
8
400
3200
9
Design and supply of Detailed Signaling Circuits including
location diagram, Fuse & Negative Tag. Analysis, Contact
analysis, Relay Rack Arrangement and wire count sheets etc. in
A3 size. Completion circuit shall be plotted in AutoCAD. The
contractor shall initially supply 2 sets of circuits duly signed by
the circuit designer having substantial experience on design
side for making such circuits, complete for approval of
Railways. Railways will return one set of circuit to the
contractor duly approved with alterations /corrections, if any.
The contractor shall incorporate Railway's alterations/
corrections in the original tracings & CD without any deviation
and submit two copies of the modified circuits. Original tracings
so modified & final CD complete in all respects along with 4
sets of final approved circuits (out of which one set shall be
supplied in transparent polythene bags. Only two sheets of
circuits shall be placed in one polythene bag each) shall be
submitted to the Railways in case there are no further
alteration suggested by Railways. This also includes preparation
& submission of cable route plan.
Job per
Gate
1
12000
12000
Signals - Units, Structures & Fixtures
10
Excavation and casting of main signal foundation as per Drg.
No. RST 11173 (SK 752) with contractor's own materials
including cement and anchor bolts of standard size. The
required scaffolding Ferma etc for casting of foundation will
have to be brought by the contractor at his own cost.
No
4
4002
16008
11
Erection of CLS Post with Surface base and signal unit on
top or on OFF set Bracket, fixing of front and back
staging, ladder and guards, signal name plates/boards if
any with contractors own brackets and fixing materials.
This also includes erection of auxiliary signals like calling
on, shunt signal if any. The work shall be done as per
instructions of Rly engineer at site.
No
4
1525
6100
12
Fixing of warning board with contractors own material. The
work shall be done as per instruction of Rly engineer at site.
No
2
253
506
13
Termination of tail cable on Main signal units and wiring
with contractor own material, fixing of lenses etc. The
No
4
479
1916
No
No
No
4
4
250
985
600
7
3940
2400
1750
Per
conductor
240
5
1200
work shall be done as per instruction of Rly engineer at site.
14
(a)
(b)
15
16
(a)
Apparatus cases
Fabrication and fixing of Hylam board in location box by
providing all fixtures as per Railway Drawing including
fixing of PVC coated string rods at the back side for cable
support with contractor's own materials. The work shall
be done as per Drg. and arrangement similar to
RST/C/11175/A, 11176/A & 007/I&II as per instructions
of Rly engineer at site.
Single Case
Quarter case
Fixing of ARA Terminals and fuse blocks with provision of
holes on hylam sheets and fixing by galvanized nuts &
bolts. This includes provision of two additional holes on
the hylam board on either side for cable conductor entry.
The work shall be done as per the instructions of Rly
engineer at site.
Termination of cable cores on ARA terminal/fuse blocks,
8 way terminals block in the apparatus cases/ cable
termination rack. This includes all associated works of
pulling out the cable from underground. The work shall
be done as per location plans and instructions of Rly
engineer at site.
Single case
17
(a)
18
Termination of cable cores on ARA terminal/fuse blocks,
8 way terminals block in the apparatus cases/ cable
termination rack. This includes all associated works of
pulling out the cable from underground. The work shall
be done as per location plans and instructions of Rly
engineer at site.
Quarter case
Excavation, casting and Erection of Apparatus case
foundation with contractors own MS frame, cement,
bricks and other materials. This includes filling of location
foundations with river bed sand and plastering on top of
the sand.
Job
4
350
1400
(a)
Single case as per Drg. No. S&T/CONST/JHS/T/112-A(SK-748)
No
4
3606
14424
(b)
19
Quarter case
Lettering/Numbering termination particulars, equipment
names etc. legibly and neatly in apparatus case/cable
room with contractor's own supply of paint.
Single case
Quarter case
Cable Laying
Excavation of cable trench as per cable route plan, 1 mt.
deep and 300mm wide along side the track in all types of
soil, conforming to distances as per cable route plan and
refilling after cable laying. This work includes covering of
cable laid in trenches by loose soil for a layer of 50 mm
thickness approximately before covering by shahabad
stone/bricks, clearing of route, bushes etc. The work
shall be done as per extant practice on C. Rly &
instruction of Rly engineer at site. In case depth of
trench not achievable due to site conditions
proportionate payment will be made.
Excavation of cable trench as per cable route plan,1 mt.
deep and 300mm wide along side the track in hard soil,
conforming to distances as per cable route plan and
refilling after cable laying. This work includes covering of
cable laid in trenches by loose soil for a layer of 50 mm
thickness approximately before covering by shahabad
stone/bricks, clearing of route, bushes etc. The work
shall be done as per extant practice on C. Rly &
instruction of Rly engineer at site. In case depth of
trench not achievable due to site conditions
proportionate payment will be made.
Cutting of all types of Roads preparatory to trenching
and refilling to restore them to original condition. The
work shall be done as per extant practice on C.Rly &
instruction of Rly engineer at site.
Excavation of cable trench 1m deep and 300mm wide
across the track, for track crossing and refilling after
laying of DWC pipes. The work shall be done as per
extant practice on C. Rly & instruction of Rly engineer at
site.
Excavation of pit for earthing & soil treatment with salt &
charcoal. Fixing the earth electrodes & connecting the
apparatus cases and signal post through 8 SWG GI wire
and suitable supports on MS flats of size 5mmx40mm to
the earth electrodes.
Laying of signaling/Power/Telecom cable of various
cores/sizes in trenches.
No
4
2900
11600
No
No
4
4
150
100
600
400
Mtr
3000
23
69000
Mtr
50
33
1650
Mtr
30
86
2580
Mtr
30
52
1560
No
10
800
8000
Km
6.70
3500
23450
(a)
(b)
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Supply & placing of second class bricks of standard size
225mm x 100mm x 75mm (Approx) across the trench
over the bed of loose soil on already laid cables.
Proportionate payment on the basis of volume of bricks
can be paid in case the size of the brick.
Work related with mechanical lifting barrier
Erection of lifting barriers assembly right hand/left hand
boom complete on the pedestal along with boom locking.
This include excavation & casting of predestal foundation
for left hand / right boom of lifting barriers with
contractors own materials including cement & Anchor
Bolts as per standard practice on C.Rly. & the instruction
of site engineer.
Erection of operating winch & fixing of E type locks as
per requirements.
Installation of wire diversion wheels, pulley stakes and
pullies of gate operating wire transmission, provision of
necessary wire rope joints at winches diversion wheel
and boom operating drums etc. the work includes
provision of complete transmission joi
Making of RCC channel for passage to rod run & wire run
with contractor's own material including cement. As per
instruction of the site Engineer and as per standard
practice of Central Railway.
Laying of rodding run from the accommodating cranks of
cabin ahead of lead out from GF to the last operated
function i.e. point, gate, lock bar etc. This work includes
installation of trestle in the ground at 6' intervals and
ramming of earth around it, ins
Excavation and casting of concrete foundation for 2/4 GF
confirming to C.Rly Drg. No. S&T/C/JHS/T.133 & the
instruction of site engineer.
Installation of 1/2/4-Lever Ground frame including
assembly & fixing of locking tray & plungers, fixing of E
type lock in the control lever with locking arrangement
for locking of frame, interlocking as per locking table &
all related work, conforming to C
Excavation and casting foundation for winch and gate
wire diversion wheels with contractors own materials
including cement & anchor bolts as per Drg. No.
DRM/S&T/JHS/195.
Erection of operating winch & fixing of E type key lock on
winch as per requirement and as per practice and
instruction of site engineer.
Testing & commissioning of signals including fixing of
MECR brackets bulb holders etc. inside signal
units/Location boxes with proper sizes of stainless steel
nut bolts with washers as per instruction of site-in-charge
of railway. Wiring of signal transformers, MECRs, bulb
holders, brackets & terminating flexible PVC cable of
48/0.2 fitted with suitable Dowell's make copper lug of
appropriate size as per circuit diagram of triple pole
lamp. (MECRs, bulb holders, brackets, bulbs, PVC flexible
cable to be supplied by the Railways. Stainless steel nut
bolts with washers, screws, lacing thread, Dowell's make
copper lug and all other accessories to complete this item
will be supplied by contractor.)
No
21100
1
21100
Set
1
1500
1500
Each
1
600
600
Job
1
1000
1000
R/Mtr
5
700
3500
Mtr
20
68
1360
No
1
3234.73
3234.73
No
1
2876.50
2876.50
Lot
1
1488.15
1488.15
No
0
777.70
0
No
4
300
1200
37
(a)
(b)
(c )
(d)
(e)
(f)
(g)
38
39
40
41
42
Painting /Lettering
Painting two coats of enamel paint over one coat of Red
Oxide primer on the following items after scrapping and
cleaning of the surface wherever necessary. Primer and
Paints both Asian paints make are to be supplied by
Contractor. The work shall be done as per instructions of
Rly Engineer at site and extant practice on C. Rly on
location boxes inside and outside surface.
Single case (Post box type)
Quarter case
Ground frame assembly complete
Rodding run
Cranks and compensators
Lifting barrier Gate assembly complete
Main signal post with complete fittings
Installation of warning device (hooter) arrangement as
per instructions of site-in-charge.
Miscellaneous
Placing and securing of cable route markers in trenches
at the specified interval and at diversions, joints etc
along the cable route. The work shall be done as per
extant practice on C. Rly. & the instruction of Rly
engineer at site.
Jointing & soldering of Signaling/power cable using
jointing kit as per instruction of site in-charge. This
includes digging and taking out underground cable coil
buried near location, cleaning, peeling of insulation &
refilling after jointing.
Supply of prefabricated signaling equipment housing
having outer dimensions of 6000X3000X3080 mm made
of 80 mm thick polyurethane foam sandwich panels for
equipment/relay room complete with doors, elestomeric
waterproofing, ventilators, exhaust fans, sun/rain guard,
PVC flooring tube lights, fans, etc. as per specifications
mentioned in Annexure-A along with drawings given in
the Annexure. Manufacturer's test and guarantee
certificate to be submitted by the contractor. This also
includes excavation of trenches for foundation as per
specifications mentioned in Annexure-A & drawings A, B,
C, and erection and fixing of pre-fabricated building with
all accessories supplied in item above on the foundation
erected with latest amendment. (Inspection by
consignee).
Erection of road signal.
TOTAL AMOUNT (IN RS.) OF PART-II
TOTAL AMOUNT (IN RS.) OF PART-I
TOTAL AMOUNT (IN RS.) OF PART-I + PART-II
No
No
No
R/Mtr
No
Set
No
Job
4
4
1
6
3
1
4
1
230
100
323.95
10.84
66.90
200
200
500
920
400
323.95
65.04
200.70
200
800
500
No
60
20
1200
No
6
600
3600
No
1
270500
270500
No
2
1200
2400
527071.07
908131.00
1435202.07
QUOTING OF RATES
Tenderer should not quote for individual items. Cost shall include all the Taxes,
other incidental chares etc.
Tenderer should quote “%” (percentage) above or below or at par, on the
Railway's total tender cost for schedule.
Write percentage both in figures and in words.
Tenderer should sign the following certificate.
“I/WE offer and agree to execute the above work at ……………………… % (in figures)
i.e. ……………………………………………………………………………………… percent (in words)
……………………………………… (write above or at par or below) the total combined
tender cost of schedule – Rs. 14,35,202.07/-(Rupees Fourteen Lakhs Thirty Five
Thousand Two Hundred Two & Seven Paisa only)
TENDERER
Download