Schedule for the work: Interlocking of level crossing gate no.12 in Pune-Daund section of Pune Division. PART- I (Supply portion) Sr. DESCRIPTION No. Indoor Work Relay Rack Equipments 1 Supply of Relay Rack Assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay, plug board, string rods, fuse strips with bracket, 11 Way Bus Bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-I and Rack arrangement as per Sketch no SK-727 and Rack plan as per MTJ/S&T/C/143 enclosed. 2 Supply of Tag Blocks 200 way with cover as per IRS S 77-91. 3 Supply of Main Cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, imulators, J bolt, nut/bolts & fasteners (backelite strips) etc. Siemens type & as per extant practice on C. Rly. Typical part list as per Annexure-II and rack arrangement shall be as per sketch SK 727 enclosed. 4 Supply of 8-Way Terminal strips, made of PBT, isolating barrier type as per RDSO SPN No IRS-S75/91 & Drg No 24811 alt 1 with latest amendment or of latest RDSO Specification. Indoor Cables & Jumper Wires Indoor cable, jumper wire conforming to specn No IRS: S- 76/89 (Amendment 2 or latest) colour code as per requirement. 5 Supply of Indoor Jumper Wire of various colour as per Railways standard practice of type ATC 1 x 0.6 mm dia. 6 Supply of Indoor Jumper Wire ATC 1 x 1 mm dia. 7 Supply of Flexible Cable, Single core, multi strand 10 sq mm as per specn IRS 76/89 with latest amendment (size 104/.35)(for sizes/parameters not covered by IRS 76/89 relevant clauses of IS 694/ 77with latest amendments will be applicable). 8 Supply of Flexible Cable, Single core, multi strand 6 sq mm .with Grey colour as per specn IRS 76/89 with latest amendment (size 85/.3) (for sizes/ parameters not covered by IRS 76/89 relevant clauses of IS 694/77with latest amendments will be applicable). Power Equipments 9 Supply of primary cell SITEL or similar as per IRS: S95/96. 10 Supply of ELD for measuring non earthed single phase or three phase AC networks to monitor four different AC supplies at one time, Reliance Electrical make or similar. Manufacturer's test and guarantee certificate to be submitted by the contractor. UNIT QTY RATE AMOUNT Rupees Rupees INSP. AGENCY Set 1 16578 16578 Consignee No 6 699 4194 RDSO Set 1 14582 14582 Consignee No 20 188 3760 RDSO Km 3 1282 3846 RDSO Km Km 2 0.1 3510 37200 7020 3720 RDSO RDSO Km 0.1 27900 2790 RDSO No 0 158 0 RDSO Set 1 5500 5500 Consignee 11 12 13 14 15 16 17 18 19 20 21 (a) (b) (c) (d) 22 23 24 25 26 (a) (b) 27 Supply of ELD suitable to measuring insulation resistance for circuit working on 12V DC, 24V DC and 60V DC at one time, Reliance Electrical make or similar. Manufacturer's test and guarantee certificate to be submitted by the contractor. Supply of 12V/70W Solar panel (14 nos. of solar photovoltaic cell). Supply of 2V 200AH Low maintenance lead acid cell as per IRS Specn. S-88/93. Supply of battery charger self regulating floor mounting type with 230V AC single phase input and output 24V DC 30A as per IRS S-86/92. Inverter Ferro resonant type 24V DC input/ 110V AC output 500VA as per IRS S-82/92. Relays, Base plates & Fixtures Supply of QNA1, 8F-8B, 24VDC along with plug board, retaining clip and connectors conforming to BRS: 931A, IRS: S60, IRS: S34 & IRS: S23. Supply of QNA1, 12F-4B, 24VDC along with plug board, retaining clip and connectors conforming to BRS: 931A, IRS: S60, IRS: S34 & IRS: S23. Supply of Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052) or equivalent. Supply of Off aspect ECR for Main Signal Siemens (No. RSSK 30/0014) or similar (Ref. IRS:S46) with base plate and other accessories. Supply of ON aspect ECR for Main Signal Siemens (No. RSSK 30/0013) or similar (Ref. IRS:S46) contact configuration or equivalent with base plate and other accessories. Accessories Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad or RBCO make or similar). With holder 0.6 A (System, Rapid or Malnad or RBCO make or similar) Without holder 1.6 A (System, Rapid or Malnad or RBCO make or similar) Without holder 0.6 A (System, Rapid or Malnad or RBCO make or similar) Supply of Solder wire resin core 60/40, 18/20 SWG of IS 1921/95 (Philco make). Supply of Lacing thread rolls, black, wax coated (100 mtrs each) thin & thick in the ratio of 3:4. Supply of Adhesive tape rolls, PVC (19mmx 10mtrs steel grip BHOR make or similar). Supply of Tool kit as per Annexure-III. Supply of round head type non detoriating type low voltage cartridge fuse as per Specn No IRS/S/78/92 with latest amendments. 2A Capacity 10A Capacity Outdoor Work Signals - Units, Structures & Fixtures Supply of Main Signal Post 140mm outer dia 4.5 Mtr Length as per Spec No. IRS S 6/81 with latest amendments. Set 1 3200 3200 Consignee No 14 15400 215600 RDSO No 12 1296 15552 RDSO No 2 32533 65066 RDSO No 2 15560 31120 RDSO No 10 1838 18380 RDSO No 10 1838 18380 RDSO No 2 2291 4582 RDSO No 10 2343 23430 RDSO No 0 2343 0 RDSO No 20 39 780 Consignee No 20 37 740 Consignee No 20 11 220 Consignee No 20 11 220 Consignee Kg 0.75 600 450 Consignee Roll 5 50 250 Consignee Roll 8 20 160 Consignee Set 1 10000 10000 Consignee No No 20 20 25 25 500 500 Consignee Consignee No 2 3300 6600 RITES 28 29 30 31 32 33 34 35 36 37 38 (a) (b) (c) 39 40 41 (i) (ii) 42 43 Supply of Main Signal Post 140mm outer dia 5.5 Mtr Length as per Spec No. IRS S 6/81 with latest amendments. Supply of Cast Iron Main signal surface base 140mm as per Spec No. IRS S 10 and Drg. No. 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5 mtrs long as per RDSO Drg. No. SA-23156 & signal front staging complete assembly for CLS unit as per Drg. No. RST/11413 & signal back staging as per extent C. Rly. practice. Supply of Signal No. plates as per Drg. No. RST11393. Supply of G Board as per RDSO Drg. No. SA 2345556 RST-11445 & SA 23476-77 as applicable. Supply of Goods warning Board as per RDSO Drg. No. SA 2380 (Adv). Paint and retro reflective arrangement as per Drg. No. BPL/S&T/M/47. Supply of Hand Cuff Locks. Supply of CLS Unit 2 Aspect as per RDSO No. SA25003/A/M with Holder of PBT for SL 35 Lamps as per RDSO Drg. No. SA-24831. Supply of CLS Unit 3 Aspect as per RDSO No. SA25002/A/M with Holder of PBT for SL 35 Lamps as per RDSO Drg. No. SA-24831. Supply of miniature circuit brakers 6A/230V as per IS 8828/1978. Supply of miniature circuit brakers 16A/230V Indo Asian or Indo Kupp make. Supply of Universal 110V AC/DC LED based Main Signal as per RDSO Specification: RDSO/SPN/153/2002 (or latest Drg.) for CLS signal, with current regulator and health monitoring alarm, of Colour: RED YELLOW GREEN Apparatus case Supply of Hylam sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22X1.22 Mtr as per Spec. No. IS 2036 of 1974. Supply of ARA Terminal Block as per Drg. No. SA23741 alt 3 & Spec. No. IRS S 75/91 with latest amendments. Supply of cartridge fuse block made of PBT as per RDSO Drg. No. SA-23748 Alt 4 & Spec. No. IRS S 75/91 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. 2 Amps 10 Amps Supply of Keys for miniature E Type lock keys of approved wards as per RDSO Drg. No. SA-3376 with latest amendment. Supply of Three pin switch & socket 5A ( Anchor make ). No 2 3520 7040 RITES No 4 5946 23784 RITES No 4 251 1004 Consignee No 2 275 550 Consignee No 2 1621 3242 Consignee No No 4 0 138 10106 552 0 Consignee No 0 13946 0 No 2 165 330 Consignee No 15 93 1395 Consignee No No No 4 6 4 6600 6600 8100 26400 39600 32400 RDSO RDSO RDSO No 6 2555 15330 Consignee No 150 43 6450 RDSO No No No 15 15 2 75 80 110 1125 1200 220 RDSO RDSO RITES No 8 110 880 Consignee 44 (a) (b) 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Supply of Apparatus cases with miniature E Type Locks without keys as per Spec. No. IRS S 30/64 & RDSO Drg. No. SA-3376 with latest amendments. Single case as per Drg. No. WS-8842/A with latest alteration. The sheet used should be of 10SWG. Quarter Case as per Drg. No. S&T/C/SK/154. The sheet used should be of 10SWG. Supply of Universal lock Navtal 65mm brass with 3 keys each. Supply of Lamp Holders, two pin, Bakelite type for location boxes. Supply of Electric signalling lamps 110V/40Watts for location lighting. Supply of earth electrode assemble as per Drg. No. NGP/S&T/C/308. Cable Laying Signalling cable as per IRS : S-63/89 (amendment 5 of 5/2002 or latest). Supply of armoured unscreened PVC insulated signalling cable 12X1.5 sqmm (Ref. IRS:S63/89 amendment 5 of 5/2002 or latest). Supply of armoured unscreened PVC insulated signalling cable 6X1.5 sqmm (Ref. IRS:S63/89 amendment 5 of 5/2002 or latest). Supply of Flexible wire single core multistrand 16/0.2mm as per Specn. No. IS 694 of 1977 with latest amendments (size 85/0.3). Supply of Fire Retardant Double Walled Corrugated pipe made up of Polyethylene of Size 103.5 mm inner dia and 120mm outer dia in 6M straight length as per British standard No. BSEN 50086-1 and BSEN 50086-2-4 and BIS draft Spec. Doc. No. ETD 14 (5071) and ETD 14 (5072) along with one coupler per every 6 meters. Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Consignee inspection under manufacturer certificate. Supply of G.I bend for cable entry in J.B. Supply of Gate Phone with Power supply unit. Supply of Desk type Electronic Magneto Telephone as per RDSO Spec.No.RDSO/SPN/TL/28/99 or latest. Work related with mechanical lifting barrier Supply of 2 nos of mechanically operated lifting barrier consisting of 2 pedestal pinion shafts boom, stay wire, round stop board with reflector, boom stock stand, boom block set with crank and counter weight, bell with fringes complete along with accessories as per Drg. no. SA-7982/M & SA7990/M and boom locking device assembly complete for mechanically operated lifting barrier. Supply of 4 Lever GF complete with tappets and locking tray as per RDSO Drg. no. SA935/M. Supply of Point rodding solid 32mm dia. 5500mm (18'-00) length as per RDSO Drg. No. S-3635 Alt-1, SA-3548. Supply of CI foundation A type as per IRS S3529/M. No 4 5769 23076 Consignee No 4 3100 12400 Consignee No 2 120 240 Consignee No 8 15 120 Consignee No 10 20 200 Consignee No 10 596 5960 Consignee Km 0 82415 0 RDSO Km 0 57410 0 RDSO Mtr 750 3 2250 RDSO Mtr 0 154 0 Consignee No 1 137 137 Consignee No No No 0 2 2 45 2000 1607 0 4000 3214 Consignee Consignee Consignee Set 1 115500 115500 RITES No 1 19000 19000 RITES No 4 875 3500 RITES No 4 1050 4200 RITES 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 Supply of double wire rope wheel 1 pair 225mm dia with guides to Drg. No. SA-6101/M,-01A/M. Supply of Wire Rope GI 7X7-22 SWG. Supply of Solder grade B. Supply of Adjustable screw coupling 18" long. Supply of Adjustable screw coupling 12" long. Supply of Lug joint 1 1/4" Supply of Anchor bolts with nuts 12"x 3/4" Supply of Anchor bolts with nuts 3"x 1" Supply of Nut & Bolt 1/2" x 2 1/2" Supply of Nut & Bolt 1/2" x 1 1/2" Supply of Nut & Bolt 3/4" x 3 1/2" Supply and fixing of channel plates of size 100x50x1cm duly fitted with angle iron of size 40X40X5 cms for covering channel pits. Supply of E type lock for GF as per RDSO Drg. No. SA/3376 of approved wards with keys. Supply of Circuit controller Lever type 4 way to Drg. SA-20266. Supply of Offset solid joint 32mm with coupling end to Drg. No. SA-6138/M. Supply of Crank Horizontal 300X300mm to Drg. No. SA-3414/M. Supply of Lug Eye 32mm to Drg. SA-3631/M. Supply of Electronic Solid state flasher Unit for Road traffic signal 24V DC. Supply of Dual Tone Warning Bell with 20W horn and 15W Amplifier Muconny make with operating voltage 110V AC. Supply of Road signal made of FRP RST 11540. Miscellaneous Items Supply of Cable jointing heat shrinkable type kit from RDSO approved source RAYCHEM /REPL make: 12CX1.5. Supply of cable route marker of FRP material along with FRP angle. (FRP angle should be extruded by pultrusion process & not hand moulded) as per RDSO Spec. No. RDSO/SPN/151/1997 as per sketch. Design and Supply of Level crossing Gate cum indication panel with LED bulb, of 16SWG powder coated MS sheet of size 39cm X 24cm X 10cm approx. Consisting of different colour LEDs with holder to work on 24V DC. Description on the front panel to be given by Railway engineer. Supply of 4 X 25 sq. mm Aluminium power cable. TOTAL AMOUNT (IN RS.) OF PART-I No 5 600 3000 RITES Mtr Kg No No No No No Kg Kg Kg Job 500 10 8 8 4 20 20 10 10 10 1 14 500 300 250 325 55 125 100 100 100 4000 7000 5000 2400 2000 1300 1100 2500 1000 1000 1000 4000 RITES Consignee RITES RITES RITES Consignee Consignee Consignee Consignee Consignee Consignee No 1 443 443 RITES No 5 812 4060 RITES No 2 182 364 RITES No 2 630 1260 RITES No No 2 2 175 1200 350 2400 RITES Consignee No 2 5000 10000 Consignee No 2 5000 10000 Consignee No 0 937 0 RDSO No 60 150 9000 RDSO No 1 5935 5935 RDSO Km 0 83700 0 908131.00 PART-II (Execution) Sr. DESCRIPTION No. INDOOR Relay Room Equipments 1 Installation of Relay Rack Assembly including IDF pillars complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C. Railways & the instructions of Rly engineer at site. 2 Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminal, 96 way tag block & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C. Railways & the instruction of Rly engineer at site. 3 Termination of cable cores on ARA terminal/or on 8 way terminals in the cable termination rack. This includes all associated works of pulling out the cable from under ground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site. Power Equipments 4 Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice on C. Rly. & the instruction of site engineer. The sulphuric acid & distilled water to be used for charging shall conform to specification IS 266-1961 & IS 1070-1960 respectively. (each cell 200AH) 5 Construction of Brick platform for placement of batteries in power equipment room. 6 Installation, Wiring and testing of solar panel, charging of lead acid cells, battery chargers and inverters. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on hylam sheet with connections suitable for 32A. All connectors as per site requirement to be arranged by contractor and arrangement of fixing of solar panel with contractors own material as per instructions of Railway engineer at site. 7 Wiring of Relays, Power supply equipments, ELD, Auto change over panel, warning bell etc. as per approved circuits including alteration in the existing location boxes and installation of program switches. This also includes fuse wiring, fuse blown off indication, function wiring. Any material like solder resin core, lacing threads, adhesive tapes, resistances, condensers. Accessories 8 Lettering & Numbering of Junction boxes, Apparatus cases, etc.(each function item to be taken as one unit) with Contractors on supply of paint. UNIT QTY RATE AMOUNT Rupees Rupees No 1 710 710 No 1 608 608 Per Rack 1 500 500 Per 100 AH 77 200 15400 No 1 2200 2200 Lot 1 2000 2000 Job 1 3000 3000 No 8 400 3200 9 Design and supply of Detailed Signaling Circuits including location diagram, Fuse & Negative Tag. Analysis, Contact analysis, Relay Rack Arrangement and wire count sheets etc. in A3 size. Completion circuit shall be plotted in AutoCAD. The contractor shall initially supply 2 sets of circuits duly signed by the circuit designer having substantial experience on design side for making such circuits, complete for approval of Railways. Railways will return one set of circuit to the contractor duly approved with alterations /corrections, if any. The contractor shall incorporate Railway's alterations/ corrections in the original tracings & CD without any deviation and submit two copies of the modified circuits. Original tracings so modified & final CD complete in all respects along with 4 sets of final approved circuits (out of which one set shall be supplied in transparent polythene bags. Only two sheets of circuits shall be placed in one polythene bag each) shall be submitted to the Railways in case there are no further alteration suggested by Railways. This also includes preparation & submission of cable route plan. Job per Gate 1 12000 12000 Signals - Units, Structures & Fixtures 10 Excavation and casting of main signal foundation as per Drg. No. RST 11173 (SK 752) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for casting of foundation will have to be brought by the contractor at his own cost. No 4 4002 16008 11 Erection of CLS Post with Surface base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. No 4 1525 6100 12 Fixing of warning board with contractors own material. The work shall be done as per instruction of Rly engineer at site. No 2 253 506 13 Termination of tail cable on Main signal units and wiring with contractor own material, fixing of lenses etc. The No 4 479 1916 No No No 4 4 250 985 600 7 3940 2400 1750 Per conductor 240 5 1200 work shall be done as per instruction of Rly engineer at site. 14 (a) (b) 15 16 (a) Apparatus cases Fabrication and fixing of Hylam board in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg. and arrangement similar to RST/C/11175/A, 11176/A & 007/I&II as per instructions of Rly engineer at site. Single Case Quarter case Fixing of ARA Terminals and fuse blocks with provision of holes on hylam sheets and fixing by galvanized nuts & bolts. This includes provision of two additional holes on the hylam board on either side for cable conductor entry. The work shall be done as per the instructions of Rly engineer at site. Termination of cable cores on ARA terminal/fuse blocks, 8 way terminals block in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site. Single case 17 (a) 18 Termination of cable cores on ARA terminal/fuse blocks, 8 way terminals block in the apparatus cases/ cable termination rack. This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site. Quarter case Excavation, casting and Erection of Apparatus case foundation with contractors own MS frame, cement, bricks and other materials. This includes filling of location foundations with river bed sand and plastering on top of the sand. Job 4 350 1400 (a) Single case as per Drg. No. S&T/CONST/JHS/T/112-A(SK-748) No 4 3606 14424 (b) 19 Quarter case Lettering/Numbering termination particulars, equipment names etc. legibly and neatly in apparatus case/cable room with contractor's own supply of paint. Single case Quarter case Cable Laying Excavation of cable trench as per cable route plan, 1 mt. deep and 300mm wide along side the track in all types of soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, bushes etc. The work shall be done as per extant practice on C. Rly & instruction of Rly engineer at site. In case depth of trench not achievable due to site conditions proportionate payment will be made. Excavation of cable trench as per cable route plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, bushes etc. The work shall be done as per extant practice on C. Rly & instruction of Rly engineer at site. In case depth of trench not achievable due to site conditions proportionate payment will be made. Cutting of all types of Roads preparatory to trenching and refilling to restore them to original condition. The work shall be done as per extant practice on C.Rly & instruction of Rly engineer at site. Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC pipes. The work shall be done as per extant practice on C. Rly & instruction of Rly engineer at site. Excavation of pit for earthing & soil treatment with salt & charcoal. Fixing the earth electrodes & connecting the apparatus cases and signal post through 8 SWG GI wire and suitable supports on MS flats of size 5mmx40mm to the earth electrodes. Laying of signaling/Power/Telecom cable of various cores/sizes in trenches. No 4 2900 11600 No No 4 4 150 100 600 400 Mtr 3000 23 69000 Mtr 50 33 1650 Mtr 30 86 2580 Mtr 30 52 1560 No 10 800 8000 Km 6.70 3500 23450 (a) (b) 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Supply & placing of second class bricks of standard size 225mm x 100mm x 75mm (Approx) across the trench over the bed of loose soil on already laid cables. Proportionate payment on the basis of volume of bricks can be paid in case the size of the brick. Work related with mechanical lifting barrier Erection of lifting barriers assembly right hand/left hand boom complete on the pedestal along with boom locking. This include excavation & casting of predestal foundation for left hand / right boom of lifting barriers with contractors own materials including cement & Anchor Bolts as per standard practice on C.Rly. & the instruction of site engineer. Erection of operating winch & fixing of E type locks as per requirements. Installation of wire diversion wheels, pulley stakes and pullies of gate operating wire transmission, provision of necessary wire rope joints at winches diversion wheel and boom operating drums etc. the work includes provision of complete transmission joi Making of RCC channel for passage to rod run & wire run with contractor's own material including cement. As per instruction of the site Engineer and as per standard practice of Central Railway. Laying of rodding run from the accommodating cranks of cabin ahead of lead out from GF to the last operated function i.e. point, gate, lock bar etc. This work includes installation of trestle in the ground at 6' intervals and ramming of earth around it, ins Excavation and casting of concrete foundation for 2/4 GF confirming to C.Rly Drg. No. S&T/C/JHS/T.133 & the instruction of site engineer. Installation of 1/2/4-Lever Ground frame including assembly & fixing of locking tray & plungers, fixing of E type lock in the control lever with locking arrangement for locking of frame, interlocking as per locking table & all related work, conforming to C Excavation and casting foundation for winch and gate wire diversion wheels with contractors own materials including cement & anchor bolts as per Drg. No. DRM/S&T/JHS/195. Erection of operating winch & fixing of E type key lock on winch as per requirement and as per practice and instruction of site engineer. Testing & commissioning of signals including fixing of MECR brackets bulb holders etc. inside signal units/Location boxes with proper sizes of stainless steel nut bolts with washers as per instruction of site-in-charge of railway. Wiring of signal transformers, MECRs, bulb holders, brackets & terminating flexible PVC cable of 48/0.2 fitted with suitable Dowell's make copper lug of appropriate size as per circuit diagram of triple pole lamp. (MECRs, bulb holders, brackets, bulbs, PVC flexible cable to be supplied by the Railways. Stainless steel nut bolts with washers, screws, lacing thread, Dowell's make copper lug and all other accessories to complete this item will be supplied by contractor.) No 21100 1 21100 Set 1 1500 1500 Each 1 600 600 Job 1 1000 1000 R/Mtr 5 700 3500 Mtr 20 68 1360 No 1 3234.73 3234.73 No 1 2876.50 2876.50 Lot 1 1488.15 1488.15 No 0 777.70 0 No 4 300 1200 37 (a) (b) (c ) (d) (e) (f) (g) 38 39 40 41 42 Painting /Lettering Painting two coats of enamel paint over one coat of Red Oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer and Paints both Asian paints make are to be supplied by Contractor. The work shall be done as per instructions of Rly Engineer at site and extant practice on C. Rly on location boxes inside and outside surface. Single case (Post box type) Quarter case Ground frame assembly complete Rodding run Cranks and compensators Lifting barrier Gate assembly complete Main signal post with complete fittings Installation of warning device (hooter) arrangement as per instructions of site-in-charge. Miscellaneous Placing and securing of cable route markers in trenches at the specified interval and at diversions, joints etc along the cable route. The work shall be done as per extant practice on C. Rly. & the instruction of Rly engineer at site. Jointing & soldering of Signaling/power cable using jointing kit as per instruction of site in-charge. This includes digging and taking out underground cable coil buried near location, cleaning, peeling of insulation & refilling after jointing. Supply of prefabricated signaling equipment housing having outer dimensions of 6000X3000X3080 mm made of 80 mm thick polyurethane foam sandwich panels for equipment/relay room complete with doors, elestomeric waterproofing, ventilators, exhaust fans, sun/rain guard, PVC flooring tube lights, fans, etc. as per specifications mentioned in Annexure-A along with drawings given in the Annexure. Manufacturer's test and guarantee certificate to be submitted by the contractor. This also includes excavation of trenches for foundation as per specifications mentioned in Annexure-A & drawings A, B, C, and erection and fixing of pre-fabricated building with all accessories supplied in item above on the foundation erected with latest amendment. (Inspection by consignee). Erection of road signal. TOTAL AMOUNT (IN RS.) OF PART-II TOTAL AMOUNT (IN RS.) OF PART-I TOTAL AMOUNT (IN RS.) OF PART-I + PART-II No No No R/Mtr No Set No Job 4 4 1 6 3 1 4 1 230 100 323.95 10.84 66.90 200 200 500 920 400 323.95 65.04 200.70 200 800 500 No 60 20 1200 No 6 600 3600 No 1 270500 270500 No 2 1200 2400 527071.07 908131.00 1435202.07 QUOTING OF RATES Tenderer should not quote for individual items. Cost shall include all the Taxes, other incidental chares etc. Tenderer should quote “%” (percentage) above or below or at par, on the Railway's total tender cost for schedule. Write percentage both in figures and in words. Tenderer should sign the following certificate. “I/WE offer and agree to execute the above work at ……………………… % (in figures) i.e. ……………………………………………………………………………………… percent (in words) ……………………………………… (write above or at par or below) the total combined tender cost of schedule – Rs. 14,35,202.07/-(Rupees Fourteen Lakhs Thirty Five Thousand Two Hundred Two & Seven Paisa only) TENDERER