REVISIONS JUN 25 2004 6.312 [ 160.32 ] 3.911 [ 99.34 ] 1 8-5-2008 A.0.46 AMPS WAS .29 B.REVISED NOTE 5 ECO#70000002205A LRB CZL HOLES TAPPED FOR #10-32 UNC-2A X 1/4" SCREWS (2 PLACES) SEE NOTE 4 AUG 05 2008 POWER SUPPLY SPECIFICATIONS 5.696 [ 144.68 ] GENERAL PURPOSE 2.88 [ 73.2 ] 1A EXPLOSION PROOF AC INPUT: INPUT FREQUENCY: DC OUTPUT: MAX CURRENT OUTPUT: 100-240 VAC 50-60 Hz 24 VDC 0.46 AMPS 100-240 VAC 50-60 Hz 24 VDC 0.46 AMPS OPERATING TEMPERATURE: HAZARDOUS AREA RATING: WEIGHT: MATERIAL: 0-50 C NONE 10.4 LBS (4.72 KG) 316 STAINLESS STEEL 0-50 C CLASS I, GROUPS A,B,C 10.4 LBS (4.72 KG) 316 STAINLESS STEEL ORDER NO. 10054810 10053967 & D, DIV.1 3/4-14 NPT (4 PLACES) 5.100 [ 129.54 ] CLEARANCE HOLES FOR 1/4-20 SCREWS (4 PLACES) 4.100 [ 104.14 ] THIS STANDOFF MUST BE METAL. THIS STANDOFF CONNECTS HOUSING GROUND TO CIRCUIT GROUND. 7.474 [ 189.84 ] 6.724 [ 170.79 ] 2.880 [ 73.15 ] L NOTES: 1. DIMENSIONS SHOWN IN INCHES (MILLIMETERS). 2. - - - - INDICATES FIELD CONNECTIONS BY OTHERS. 3. P/N 10047561 IS OPTIONAL MOUNTING STRAP. 4. CHECK THIS TAG FOR HAZARDOUS RATING. 1B 5. INSTALL IN ACCORDANCE WITH THE ELECTRICAL CODE OF THE COUNTRY IN USE. 6. OPERATIONAL REQUIREMENTS: A. RECOMMENDED WIRE GAUGE TYPICALLY 16 GAUGE DEPENDING ON CURRENT REQUIRED AND DISTANCE FROM POWER SUPPLY. B. MAXIMUM NUMBER OF DEVICES PER POWER SUPPLY DEPENDS ON DISTANCE AND DEVICE POWER REQUIREMENTS. SEE SPECIFIC PRODUCT INSTALLATION DRAWINGS FOR INDIVIDUAL CURRENT REQUIREMENTS. C. TO GROUND ENCLOSURE, CONNECT GROUND TO GROUND SCREW WITHIN ENCLOSURE. N SEE NOTE 3 + - + - + HOLES FOR #10-32 UNC-2A SCREWS - OPTIONAL MOUNTING BRACKET METHOD K W G THIS DRAWING IS THE PROPERTY OF MSA AND IS MADE AVAILABLE TO YOU IN SEE NOTE 6C -DC +DC -DC QTY. ORDER NO.: GP 10054810 XP 10053967 MINE SAFETY APPLIANCES CO.CONFIDENCE AND SUBJECT TO THE FOLLOWING: NO PERMISSION IS GRANTED AUTHORIZED COUNTRY +DC -DC +DC (24 VDC NOMINAL) COLOR CODE CUSTOMER___________________________ P.O. # ___________________________ LOCATION___________________________ TAG # ___________________________ BLACK BROWN RED ORANGE YELLOW PINK = = = = = = K N R O Y P GREEN BLUE VIOLET GRAY WHITE TAN = = = = = = G B V A W T . . . . . . . . . . . . . . . PITTSBURGH, PA 15230, USA MSA STANDARD SHOP PRACTICES APPLY CODE SYMBOLS CRITICAL + MAJOR A A MAJOR B 30005163 PH0730 DRAWN BY MINOR (NO MARK) B 100 % INSPECTION JOB NO. WJE TOLERANCES UNLESS OTHERWISE SPECIFIED . 6-1-2004 CHECKED BY PROJ. ENGR. S.TURNER 6-23-04 QUALITY ASSURANCE FRACTIONAL 1/64 J.DANNHARDT 6-23-04 2 PL DEC. 0.01 MANUFACTURING 3 PL DEC. 0.005 D.ALWARD 6-23-04 ANGULAR 1 deg. SEE MSA STANDARD SHOP PRACTICES FOR DRILLED HOLE TOLERANCES APPROVAL AGENCY CODE: YES NIOSH ATTR. DOC.: DATE D.BRUCE 6-24-04 C DO NOT TO PUBLISH, USE, REPRODUCE, TRANSMIT OR DISCLOSE THIS DRAWING, OR ANY INFORMATION CONTAINED THEREIN TO OTHERS WITHOUT THE PRIOR SCALE WRITTEN CONSENT OF MSA EXCEPT FOR THE MANUFACTURE OF ARTICLES FOR MSA. DWG. SCHUTZVERMERK NACH DIN 34 BEACHTEN. MSA AUER GmbH. INSTALLATION OUTLINE, 24 VDC POWER SUPPLY MODULES, ULTIMA XE CADD REF: 10000020128 DOCUMENT NO. D SK 10000020128 SCALE: 1.000 SHEET 1 OF 1