Single Circuit Horizontal and Vertical Water Source Heat Pumps Product Catalog Sizes: 009 to 062 – Horizontal Sizes: 012 to 062 – Vertical Model: U Vintage Catalog MAMM-WHSP-PC-1UE (January 2013) Contents Single Circuit Horizontal and Vertical...................................................................................................1 Nomenclature.......................................................................................................................................3 General Description – Single Circuit Horizontal...................................................................................4 General Description – Single Circuit Vertical.......................................................................................5 Benefits – Single Circuit Horizontal and Vertical..................................................................................6 Unit Construction and Components.....................................................................................................7 Controls................................................................................................................................................8 Options ..............................................................................................................................................13 Factory Mounted Options...................................................................................................................14 Field Mounted Options.......................................................................................................................16 Engineering Specification...................................................................................................................17 Applications and Design Considerations ..........................................................................................19 Nominal Capacity – Horizontal*.........................................................................................................23 Nominal Capacity – Vertical*..............................................................................................................24 Application Limits...............................................................................................................................25 Submittal Data – Horizontal Sizes 009 to 062, Right Hand...............................................................26 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect..................31 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil...........37 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect.......................................................................................................................42 Submittal Data – Horizontal Sizes 009 to 062, Left Hand.................................................................48 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect....................53 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil.............59 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and NonFused Disconnect...............................................................................................................................64 Submittal Data – Vertical Sizes 012 to 072, Right Hand...................................................................69 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect......................73 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil...............79 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil and NonFused Disconnect...............................................................................................................................83 Submittal Data – Vertical Sizes 012 to 072, Left Hand......................................................................88 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect........................92 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil..................97 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil and NonFused Disconnect.............................................................................................................................101 Catalog MAMM-WHSP-PC-1UE (January 2013) 2 Nomenclature F Voltage 036 Size (BTUH Cooling) H H Unit Type Temperature Range D = 208-230/1/60 009 = 9,000 H = Horizontal H = Standard Range E = 265/1/60 012 = 12,000 V = Vertical L = Low Temperature F = 208-230/3/60 013 = 13,000 G = 460/3/60 016 = 16,000 J = 380/3/50 019 = 19,000 K = 575/3/60 024 = 24,000 L = 220-240/1/50 030 = 30,000 S = 380/3/60 036 = 36,000 U Design Vintage 043 = 43,000 052 = 52,000 062 = 62,000 “Mammoth” is a registered trademark of Mammoth, Inc. ©Mammoth, Inc. 2012. All rights reserved throughout the world. Illustrations cover the general appearance of Mammoth products at the time of publication and Mammoth, Inc. reserves the right to make changes in design and construction at anytime without notice. The following are trademarks or registered trademarks of their respective companies: LonTalk from Echelon Corporation, BACnet from ASHRAE Catalog MAMM-WHSP-PC-1UE (January 2013) 3 General Description – Single Circuit Horizontal U-vintage, ceiling-hung water source heat pumps are typically installed in hallways and other corridors, away from the occupied space for reduced sound and to allow easier service access. Each single circuit unit provides heating and cooling to a specific space within the building. Mammoth offers some of the most compact horizontal water source heat pump units in the industry with critical components located to provide easy maintenance and service access in a horizontal application. Basic Features: • • • • • • • • Ten units from ¾ to 5 tons Standard or geothermal operation R-410A refrigerant EER up to 16.8 and COP rating to 4.8 Fully run-tested with water in both the heating and cooling mode Compact size Available with left or right hand water connections to match application requirements ETL listed and AHRI/ISO 13256-1 certified for capacity and efficiency Catalog MAMM-WHSP-PC-1UE (January 2013) • • • • • ASHRAE 90.1 compliant Rotary and scroll compressors Insulated cabinet with removable access panels for easy service HP-5 microprocessor-based control system including condensate overflow protection Optional EPiC™ DDC controls provide for optimum performance using the control scheme or building management system and protocol of your choice 4 General Description – Single Circuit Vertical U-vintage, floor-mounted water source heat pumps are typically installed in closets or small mechanical rooms near the occupied space. Offering an industry-leading EER and COP, each single circuit unit provides cooling and heating for a specific zone within the building. Mammoth offers some of the quietest water source heat pump units in the industry, allowing units to be located near the occupied space with minimal acoustic impact. Basic Features: • Seven units from 1 to 5 tons • Standard or geothermal operation • R-410A refrigerant • EER up to 15.8 and COP rating to 4.8 • Fully run-tested with water in both the heating and cooling modes • Special construction for extremely quiet operation • Available with left or right hand water connections to match application requirements • ETL listed and AHRI/ISO 13256-1 certified for capacity and efficiency Catalog MAMM-WHSP-PC-1UE (January 2013) • • • • • ASHRAE 90.1 compliant Rotary and scroll compressors Insulated cabinet with removable access panels for easy service HP-5 microprocessor-based control system including condensate overflow protection Optional EPiC™ DDC controls provide for optimum performance using the control scheme or building management system and protocol of your choice 5 Benefits – Single Circuit Horizontal and Vertical High Efficiency Components are selected for high efficiency to conserve energy and reduce operating costs. Horizontal units can have an EER up to 16.8 with a COP rating to 4.8. Vertical units can have an EER up to 15.8 and COP rating to 4.8. Units can help a project obtain LEED® certification. Application Flexibility Boiler/tower or geothermal selections provide design flexibility to meet project performance criteria and budget requirements. Multiple discharge arrangements and a wide variety of factoryinstalled options allow units to be configured to meet design and project requirements. Coolingonly units expand the range of possible applications. R-410A Refrigerant Mammoth units incorporate R-410A refrigerant that has no ozone depletion potential or phase-out date. This minimizes the impact on our environment and protects against refrigerant availability over the life of the units. Easy Maintenance Each side of the vertical unit has removable access panels to the compressor, fan and control box. The back of the unit has access panels to the compressor and fan. The front of the unit, under the coil, has removable panels for additional access. Each refrigerant circuit has high and low side access valves for easy servicing. Factory-installed filter racks that accommodate return air ducts provide easy access for routine filter replacement. Controls Flexibility Units come standard with an HP-5 controller to provide independent, standalone control of all unit functions. An optional factory-installed EPiC™ DDC system provides for communication with common building automation system protocols such as BACnet®, LonTalk® and Modbus®. Durable and Reliable Operation Mammoth units are engineered and components are selected for long-life and reliable operation. Optional cupro-nickel inner tubes of the heat exchanger provide additional protection in applications using well water and city water. Ease of service encourages routine maintenance for peak operation. Horizontal units have multiple removable access panels to allow easy access to the compressor, fan and control box. Catalog MAMM-WHSP-PC-1UE (January 2013) 6 Unit Construction and Components Cabinet Refrigeration System The cabinet is constructed of G-60 galvanized steel. Internal metal parts are also fabricated from galvanized steel. Cabinet insulation is ¾ inch, 1 ½ pound density, skin-coated fiberglass. The entire bottom panel is insulated with the same material to prevent condensation and reduce noise transmission. The refrigeration system consists of a hermetic compressor, coaxial water to refrigerant heat exchanger, airside coil, thermal expansion valve metering device, high and low side access valves, reversing valve and safety controls. Compressors are mounted on neoprene isolators and heavy gauge mounting rails for minimum noise transmission and quiet operation. Horizontal units have one air coil in the front of the unit. The compressor section is separated from the fan section by an insulated divider panel. There are three access panels for the control box, fan and compressor sections to allow service of all major components without removing the unit from the ceiling. The control box has its own entrance panel to limit exposure to other sections not requiring service. All major electrical components, including transformer, relays, contactor(s) and circuit board, are located inside the control box making it convenient to electrically service the unit. The corner post adjacent to the control box accepts a line voltage conduit connection. The low-voltage thermostat connections are conveniently made terminal strips. The hanging rail runs along the bottom of the unit. Vertical units are arranged with the vertical air coil in the front of the unit and the compressor section below. Each side of the unit has multiple access panels to the control box, fan, and compressor. The back of the unit has access panels to the fan and compressor sections. The front of the unit under the coil has removable panels for additional access Each unit includes 1 inch throwaway filters in a factory-mounted filter bracket designed to accommodate a return air duct connection. The standard brackets can accommodate either 1-in or optional 2-inch filters. Filters are removed horizontally. All units incorporate ½ to 1-inch female NPT copper water connection fittings outside the cabinet for connection to flexible hose or rigid piping. Condensate lines are internally trapped on vertical units. A 7/8” O.D. copper condensate connection outside the cabinet, adjacent to the water connections, is provided on each unit. Catalog MAMM-WHSP-PC-1UE (January 2013) The water to refrigerant coaxial coil consists of a copper inner tube and a steel outer tube. It is rated for 620 psig on the refrigerant side and 400 psig on the water side. Large tube diameters prevent clogging. The air coil is a copper tube, aluminum finned type selected for high efficiency. The reversing valve is energized in the cooling mode and is fail-safe to the heating mode. Safety controls include high and low refrigerant pressure switches (loss of charge protection). A lockout relay built into the standard microprocessor board prevents the compressor from operating if any safety switch trips. Fan Section The fan section includes the fan wheel/housing, motor, discharge outlet and drain pan that is located under the air coil. Components are separated from the compressor section to limit noise transmission. The forward curve centrifugal fan wheel is balanced for minimum vibration. The drain pan is insulated from the unit casing to prevent sweating. The fan motor is a 5 1/2 -inch diameter, six-pole, multi-speed, PSC-type with internal overload protection. With a maximum speed of 1200 rpm, the fan is quieter than smaller diameter, 4-pole motors used in similar products. The fan motor incorporates integral flex mounts to minimize vibration transmission. Horizontal units are configured for straight-through discharge as standard with an optional side discharge. Vertical units are configured for top discharge as standard. Each configuration can be factory-provided or converted from one to the other in the field. 7 Controls HP-5 Controller The standard HP-5 microprocessor board provides complete control of the unit compressors, reversing valves, fan, safety features and troubleshooting fault indicators. • Random start delays the startup of the unit 5 to 35 second after coming off from an unoccupied or shutdown cycle to prevent all the units from starting at the same time. • Condensate overflow protection stops compressor operation if the drain pan sensor detects moisture at the top of the pan to prevent overflow due to clogged or slow draining condensate piping • Compressor anti-short cycle protection prevents the compressor from being energized for 5 minutes after shutoff to limit compressor cycling and to extend compressor life. • Shutdown allows the units to be shutoff with no compressor or fan operation in the event of an emergency. Shutdown is activated from a two-wire signal. Catalog MAMM-WHSP-PC-1UE (January 2013) • • • • • • LED diagnostic display communicates the status of the unit to indicate: normal operating mode, low voltage condition, High voltage condition, shutdown mode, high pressure/ low pressure switch fault, and condensate sensor. High and low voltage protection shuts off the unit in the event the unit voltage is too high or too low to protect the internal components from damage. Safety lockout prevents compressor operation if any of the safety switches trip: high pressure/ low pressure switch, condensate overflow protection or optional freezestat. The unit can be reset from the wall thermostat or the main unit disconnect. Auto reset allows the unit to automatically reset itself three times within a 100 minute period; two-minute startup delay at initial startup; and at loss of power. Fan interlock makes sure the fan is on when the compressor is on. Lockout alarm sends a signal to the thermostat to illuminate an LED if so equipped. 8 The control also closes a set of dry contacts if any of the safety switches trip for remote monitoring. A set of dry contacts (set of normally open and closed) are activated when the compressor is on to operate a motorized valve. If the system is equipped with the proper thermostat the following features are also available: • Night setback allows heating operation at a lower set point to maintain a minimum space temperature, which is activated by a two-wire signal. The fan will cycle with the compressor. • Night setup allows cooling operation at a higher set point to maintain a maximum space temperature which is activated by a two-wire signal. The fan will cycle with the compressor. • Override allows night setback or setup modes to be de-activated for 2 hours while the unit resumes operation at its daytime set points. Override operation is activated by a push button on the wall thermostat. EPiC™ DDC Controller The optional factory-integrated EPiC DDC controller provides control flexibility that can be easily customized to meet any sequence of operation. It is fully capable of operating in a 100% stand-alone mode or can connect to a Building Automation System (BAS) using any of today’s four leading protocols: BACnet, Modbus, N2, and LonTalk. The base controller provides ample input/output capacity, plus support for an expander board if additional I/O capacity is required. I/O 560 controller key features: • I/O point count: 5 digital outputs (relayed), 6 universal inputs • Built-in protocol support: BACnet (ARC156 and MS/TP), Modbus RTU, and N2. Protocols and baud rates are DIP switch selectable. • LonWorks optional plug-in communications boards • On-board battery-backed real-time clock enables full stand-alone scheduling capabilities, as well as historical trend data storage, and alarm event time-stamping. • Powerful, high-speed 16-bit processor with 1MB Flash memory and 512 KB of batterybacked RAM. Catalog MAMM-WHSP-PC-1UE (January 2013) • Local laptop computer access ports enable full diagnostic and configuration capabilities. I/O 583 controller key features: • I/O point count: 5 digital outputs (relayed), 8 inputs (6 universal and 2 for optional adjustment POTS), and 3 analog outputs. • Built-in protocol support: BACnet (ARCNET and MS/TP), Modbus RTU, and N2. Protocols and baud rates are DIP switch selectable. • Optional plug-in communications boards: LonWorks and Ethernet (for BACnet-over-IP support and HTTP for serving up a web page). • On-board battery-backed real-time enables full stand-alone scheduling capabilities, as well as historical trend data storage, and alarm event time-stamping. • Powerful, high-speed 16-bit processor with 1MB Flash memory and 512KB of batterybacked RAM. • Local laptop computer access ports enable full diagnostic and configuration capabilities. I/O 6126 controller key features: • Used with applications having options requiring a greater number of outputs and inputs. • I/O point count: 6 digital outputs, 12 universal inputs, and 6 analog outputs. I/O points can be increased by use of an optional I/O Flex Expander. • Optional built-in protocol support: BACnet (ARCNET, MS/TP, and PTP modes), Modbus (RTU and ASCII modes supported), N2, or LonTalk. • Powerful, high-speed 16-bit microprocessor with 1 MB Flash memory and 1 MB of batterybacked RAM • Built-in support through a Rnet port for control’s custom configurable keypad/display unit, BACview6 (4-line by 40 character per line display); for intelligent sensors. • As additional options are added an I/O 8160 expander will be needed 9 I/O 560 – Example of I/O’s Universal Input Description Jumper Setting 1 Supply Air Temperature (Monitor Only) Thermistor/Dry Contact 2 Condenser Leaving Water Temperature Thermistor/Dry Contact 3 Condenser Entering Water Temperature Thermistor/Dry Contact 4 Compr Lckt/Overflow Compr.#1 HP-5 Alarm Compr. #2 Alarm Thermistor/Dry Contact 5 Load Shed* Compr#1Q HP-5 Alarm* Compr#2Q HP4 Alarm Thermistor/Dry Contact 6 Emergency Shut Down External Clock (Start) Dirty Filter (Switch Opt) Thermistor/Dry Contact Rnet 1 Digital Output 1 Description Room/Return Air Temperature (RS Std) or Room Air Temperature/Set-Point/Override (RS-Pro, Optional) Description Supply Fan Start Jumper Setting n/a Jumper Setting Dry Contact for 24 VAC 2 Compressor Call #1 Dry Contact for 24 VAC 3 Compressor Call #2 or on/off Waterside Economize or on/off Aux. Heat Dry Contact for 24 VAC 4 Reversing Valve or on/off Waterside Economizer or on/off Aux. Heat Dry Contact for 24 VAC 5 Common Alarm Dry Contact for 24 VAC Options are in italics. Common options are bolded * Cost add option must be ordered to get multiplexing board ** A minimum of one keypad display must be ordered per project to set required set-points *** A protocol will be a cost add option Catalog MAMM-WHSP-PC-1UE (January 2013) 10 I/O 583 – Example of I/O’s Universal Input Description Jumper Setting 1 Supply Air Temperature (Monitor Only) Thermistor/ Dry Contact 2 Condenser Leaving Water Temperature Thermistor/ Dry Contact 3 Condenser Entering Water Temperature Thermistor/ Dry Contact 4 Cooling Coil Leaving Air Temperature Sensor Thermistor/ Dry Contact 5 Space or Return Humidity Thermistor/ Dry Contact 6 Load Shead* Compr #1Q HP-5 Alarm* 7 Compr Lckt/ Overflow Compr #1 HP-5 Alarm 8 Emergency Shut External Dirty Filter Dirty Filter Down Clock (Start) (Switch Opt) (Switch Opt) Rnet 1 Analog Output Compr #2 Alarm Compr #2Q HP-5 Alarm Thermistor/ Dry Contact Compr #2Q HP-5 Alarm Compr #2 Alarm Thermistor/ Dry Contact Description Thermistor/ Dry Contact Jumper Setting Room/Return Air Temperature (RS Std) or Room Air Temperature/Set-Point/Override (RS-Pro, Optional) Description n/a Jumper Setting 1 Reheat** 0-10VDC 2 Water Side Economizer** 0-10VDC 3 Auxiliary Heat** 0-10VDC Analog Output Description Jumper Setting 1 Supply Fan Start Dry Contact for 24 VAC 2 Compressor Call #1 Dry Contact for 24 VAC 3 Compressor Call #2 Dry Contact for 24 VAC 4 Reversing Valve Dry Contact for 24 VAC 5 Common Alarm Dry Contact for 24 VAC Options are in italics. Common options are bolded. * Cost add option must be ordered to get multiplexing board ** Requires DC relay for single stage, UCS for multi-stage, or actuator for modulating control *** A minimum of one keypad display must be ordered per project to set required set-points **** A protocol will be a cost add option Catalog MAMM-WHSP-PC-1UE (January 2013) 11 I/O 6126 – Example of I/O’s INPUTS Point UD #1 Description +Pulse BMS Supply Air, Duct Static Reset or Room Air Temperature Setpoint RTD/Therm/Dry System Switch UD #2 UD #3 Room Air Temperature UD #4 Contact, 0-10VDC, High Static UD #5 0-20MA Economizer Lockout Emergency Shut Down Remote Start Low Static VFD in Bypass Cooling Lockout Heating Lockout Compressor Fault Condensate Overflow UD #6 Supply Fan Status UD #7 Duct Static Pressure or Airflow Switch UD #8 Filter Static Pressure or Dirty Filter Switch #1 UD #9 Outside Air Temperature (AiSE Only) UD #10 Condenser Water Temperature UD #11 Entering Air Temperature or Return Air Temperature (AiSE) UD #12 Supply Air Temperature OUTPUTS Point Description UO #1 4-20mA, 0-10Vdc Spare 0-10 Vdc Economizer Valve (WiSE)/Damper Control Signal (AiSE) UO #2 UO #3 Heating Source Control Signal UO #4 WiSE Bypass Valve Signal UO #5 Spare UO#6 Supply Fan VFD Control Signal DO #1 120 VAC Start Supply Fan DO #2 FORM C Start Condenser Pump or Switch Reversing Valve DO #3 Field-Lin (MWU or Open Min OA) DO #4 Common Alarm DO #5 Compressor Call #2 DO #6 Compressor Call #1 Catalog MAMM-WHSP-PC-1UE (January 2013) 12 Options Code Description Base Options Sound Packages A1 QB sound package A2 SB/compressor sound blanket A3 QB/ sound package; SB/ compressor sound blanket; FI/ foil backed insulation (1/2”) Extra Controls or Electrical Options B1 No extra electrical options B2 TR/ 75VA transformer B3 Aux contacts/ close with compressor B4 Aux contacts/close with fan B5 Aux contacts/close with compressor; TF & SB/ two speed fan selection/toggle switch; TR /75VA transformer B6 B7 B8 B9 B10 Aux contacts/close with fan; TF & SB/ two speed fan selection/toggle switch; TR /75VA transformer Aux contacts/close with compressor; TF & SB/ Two speed fan selection/remote signal (24VAC) input; TR/ 75VA transformer Aux contacts/close with fan; TF & SB/ Two speed fan selection/remote signal (24VAC) input; TR/ 75VA transformer Aux contacts/close with compressor; TF & SB/ Two speed fan selection/remote signal (24VAC) input; TR/ 75VA transformer; PP/Phase protectionfan selection/remote signal (24VAC) input; TR/ 75VA transformer; PP/Phase protection Aux contacts/close with fan; TF & SB/ Two speed fan selection/remote signal (24VAC) input; TR/ 75VA transformer; PP/Phase protection B11 Aux contacts/close with compressor; CT/Switching on fan operation; TR/75VA transformer; PP/Phase protection B12 Aux contacts/close with fan; CT/Switching on fan operation; TR/75VA transformer; PP/Phase protection Refrigeration Sub Packages C1 Standard/No refrigeration option C2 HGBP/ Hot gas by pass C3 HGBP/Hot gas by pass; LF/Air coil freeze protection C4 HGRH/Hot gas re-heat/on-off control; HGBP/Hot gas by pass; LF/ Air coil freeze protection Special Packages D1 SP/Stainless steel drain pan Dirty Filter Switch Option E1 Dirty Filter Switch Leaving Water Temperature Switch F3 WT/leaving water temp. switch Catalog MAMM-WHSP-PC-1UE (January 2013) 13 Factory Mounted Options Mammoth Water-Source Heat Pumps offer numerous factory-installed options that can help minimize field labor and enhance system performance Cooling-only units are available for those applications requiring no heating from the unit. An extended-range or low temperature option is available on all heat pump units to allow heating operation down to 25°F and cooling operation down to 40°F entering fluid temperature. The package includes a freezestat water switch, an insulated coaxial heat exchanger and insulated refrigerant piping. Cupro-nickel tubes on the inner tube of the heat exchanger provide additional corrosion protection in applications using well or city water. A sound package includes ¾” thick, 1½ lb. density fiberglass insulation on the entire unit, as well as the addition of a heavy dampening material, over the entire bottom panel for reduced radiated sound levels A field-supplied DDC controller can be factory mounted and wired by Mammoth. This allows the engineer to specify a specific control manufacturer and achieve simple interface of the network system The waterside economizer kit allows pre-cooling of the entering air to take advantage of cool loop water and to reduce compressor operation during cool weather. The kit includes a two-row water coil, 3-way diverting valve and an entering water thermostat to divert the water through the coil if the temperature is below set point. Catalog MAMM-WHSP-PC-1UE (January 2013) A freezestat is available to sense the leaving water temperature. If the leaving water falls below 32°F, the freezestat will open the safety lockout circuit and shut down the compressor. This option is beneficial on well water and city water applications where water temperatures can drop during the heating season. Hot gas bypass control is available to artificially load the evaporator during cooling to maintain refrigerant suction temperature during low load conditions. This option includes a hot gas bypass valve. Hot gas reheat is available to reheat saturated air coming off the cooling coil without using an external heat source. A motorized valve is available to shut off the water flow through the unit when the compressor is off. The valve is a normally open-power close type and will open in the event of power loss. A dirty filter switch informs the maintenance personnel to change filters. The switch senses the pressure drop across the filter. A 75 VA transformer replaces the 50VA transformer for additional power to operate a choice of low voltage controls, accessories or relays, especially in the case of field-supplied control systems, which require additional power. The 75 VA transformer has a built-in circuit breaker. 14 Field Mounted Options Thermostats 7 day programmable, 2 stage heat/cool with (P/N 71116207) 5 day programmable, 1 stage heat/cool (P/N 71116205) • • • • 5/1/1 day or 24-hour programmable models 4 time and 4 temperature settings per program (heat & cool) Easy-to-read LCD Choice of battery-powered or hardwired 7 day programmable, 2 stage heat/cool (P/N 71116206) • • • • 7, 5/1/1, 5/2 day or 24-hour programmable models 4 time and 4 temperature settings per program (heat & cool) Easy-to-read LCD Choice of battery-powered or hardwired • • • • Dual-powered: battery-powered or hardwired with battery back-up 7 day programmable, 2 stage heat/cool with humidity control (P/N 71116208) • • • • • Catalog MAMM-WHSP-PC-1UE (January 2013) 7 day, 5/1/1 day programmable or non-programmable (installer selectable) 4 time and 4 temperature settings per program: 2 setbacks (heat and cool) or selectable 2 time and 2 temperature settings with 1 setback Easy-to-read 12-in2 touchscreen display 7 day, 5/1/1 day programmable or non-programmable (installer selectable) 4 time and 4 temperature settings per program: 2 setbacks (heat and cool) or selectable 2 time and 2 temperature settings with 1 setback Humidification and dehumidification control (dehumidification Rh range 40-90% and humidification Rh range 5-50%) Easy-to-read 12-in2 touchscreen display Dual-powered: battery-powered or hardwired with battery back-up 15 Field Mounted Options Flexible hose kits Deluxe Hose Kits Flexible hose kits are available in 1/2 inch, 3/4 inch and 1-inch diameters and 24 or 36 inches long. Each hose is constructed of braided stainless steel and has NPT steel fittings with a swivel at one end. Hoses are rated at a minimum 225 psi. Fire rated hose. Fiber reinforced EPDM stainless steel braid hoses with swivel connections. Maximum working pressure 400 PSI for ½” – 1”, and 300 PSI for 1 ¼” – 2”. Condensate Hose A clear vinyl condensate hose includes clamps for connection to the condensate drain tube Catalog MAMM-WHSP-PC-1UE (January 2013) Ball valves, UltraMatic and UltraY Y-strainer with drain valve and pressure temperature test port. Maximum working pressures (600 PSI/ 325°F) 600W.O.G, body material: Forged brass ASTM B283 ½” – 1½”L and Cast Brass ASTM B283 1½”S and 2”, 20 mesh 304 stainless steel strainer, chrome plated brass ball. Automatic flow control “UltraMatic” – accessible cartridge, Viton O-ring with two pressure temperature test plugs. Some assembly required. 16 Engineering Specification General: Furnish and install water-source heat pumps as indicated on the plans as listed in the unit schedule. All units must be factory run-tested in both the heating and cooling modes with full water flow. All equipment must be certified for capacity and efficiency by AHRI and be safety agency listed with ETL. Unit Construction: The outer casing and internal support parts shall be fabricated from G-60 galvanized steel. All interior metal parts exposed to moisture and cold temperatures shall be insulated with acoustic-type, 3⁄4-inch, 1.5-pound, skin-coated fiberglass. The fan section shall be separated from the compressor compartment. A galvanized steel drain pan shall extend the full length of the air coil and include a 7⁄8-inch copper drain tube extending outside the unit casing. A minimum of three removable panels shall provide access to the compressor, control box and fan sections. Unit shall have a 1-inch thick throwaway filter located in a filter rack capable of accepting a return air duct connection. Supply and return water connections shall have female NPT copper fittings located outside the cabinet for connection to flexible hoses. Horizontal units shall have factory-mounted, heavy steel hanger brackets secured to the top of the unit complete with rubber compression isolators to suspend the unit from the ceiling. Refrigeration System: Each unit shall have a sealed refrigerant circuit including a hermetic compressor, reversing valve, thermal expansion valve, airside coil, coaxial water-to-refrigerant coil, high side and low side access ports and safety controls. The hermetic compressor shall have thermal overload protection and shall be mounted on neoprene isolators as recommended by the compressor manufacturer. The airside coil shall be of copper tube, aluminum-finned construction and rated for 620 psig. The water-to-refrigerant coil shall be coaxial design with copper inner tube and steel outer tube and rated at 620 psig on the refrigerant side and 400 psig on the water side. Safety controls include a high refrigerant pressure switch and a low refrigerant pressure switch for protection against loss of charge and extreme low temperature operation. Each unit shall be capable of starting with 50°F entering air temperature and 50°F entering water temperature in the heating mode with ARI water and airflow rates. The reversing valve shall be Catalog MAMM-WHSP-PC-1UE (January 2013) energized in the cooling mode for “fail-safe” to the heating mode. Fan Section: Units up to 5 tons shall have a directdrive fan assembly with a multispeed, 5 1/2 -inch diameter, six-pole, PSC motor with internal overload protection and a maximum rotational speed of 1,200 rpm. The motor shall be isolated from the fan housing with integral flex mounts. Horizontal units shall be capable of end or straight air discharge arrangement and be capable of being reversed in the field. Electrical: All electrical components shall be housed in a separate enclosure with its own access door. Controls shall include fan relay, compressor contactor, 24-volt transformer, microprocessor board, and capacitor(s). Each compressor circuit shall have a lockout circuit to disable compressor operation in the event of a trip of any of the safety switches and to send a signal to an LED on the wall thermostat. The lockout circuit shall be capable of being reset from the wall thermostat or from the main disconnect switch. Additional electrical components shall include a reversing valve. Geothermal Units: Geothermal units shall be applied to ground coupled applications. The units shall be AHRI/ISO 13256-1 certified for operation at 26°F to 110°F entering brine temperature. The unit shall have insulated refrigerant and water piping, insulated coaxial coil, and a low leaving water temperature (freezestat) safety switch. HP5 Control System: Mammoth offers a microprocessor-based unit controller and includes features such as: • Random start delays the startup of the unit 5 to 35 seconds after coming off from an unoccupied or shutdown cycle to prevent all the units from starting at the same time. • Condensate overflow protection stops compressor operation if the drain pan sensor detects moisture at the top of the pan to prevent overflow due to clogged or slow-draining condensate piping. • Compressor anti-short cycle protection prevents the compressor from being energized for 5 minutes after shutoff to limit compressor cycling and to extend compressor life. 17 • • • • • • • Shutdown allows the units to be shutoff with no compressor or fan operation in the event of an emergency. Shutdown is activated from a two-wire signal. LED diagnostic display communicates the status of the unit to indicate: normal operating mode, low voltage condition, high voltage condition, shutdown mode, high pressure/low pressure switch fault, freezestat fault, and condensate sensor. High and low voltage protection shuts off the unit in the event the unit voltage is too high or too low in order to protect the internal components from damage. Safety lockout prevents compressor operation if any of the safety switches trip: high pressure/ low pressure switch, condensate overflow protection or optional freezestat. The unit can be reset from the wall thermostat or from the main unit disconnect switch. Auto reset allows the unit to automatically reset itself three times within a 100 minute period Two-minute startup delay at initial startup and at loss of power Fan interlock makes sure the fan in on when the compressor is on Catalog MAMM-WHSP-PC-1UE (January 2013) • • Lockout alarm sends a signal to the thermostat to illuminate an LED and closes a set of dry contacts if any of the safety switches trip or if the unit is in shutdown mode due to a remote signal or to high/low voltage, auxiliary dry contacts (set of normally-open and normallyclosed) are activated when the compressor is on to operate a motorized valve. When coupled with the proper thermostat the HP-5 board is also compatible with the following features: o Night setback allows heating operation at a lower set point to maintain a minimum space temperature, which is activated by a two-wire signal. The fan will cycle with the compressor. o Night setup allows cooling operation at a higher set point to maintain a maximum space temperature, which is activated by a two-wire signal. The fan will cycle with the compressor. o Override allows night setback or setup modes to be de-activated for 2 hours while the unit resumes operation at its daytime set points. Override operation is activated by a push button on the wall thermostat. 18 Applications and Design Considerations Boiler/Tower Vertical Closed Loop Also called a standard, conventional or water loop system, a boiler/tower system uses a two pipe water circulating system to add, remove, or transfer rejected heat to other units throughout the building. The system is not geothermal – typically using a natural gas or electric boiler located in a mechanical equipment room to provide heat. A cooling tower is used to dissipate waste heat. This system is typically the lowest cost of the loop options. (AHRI 320 / ISO 13256-1) Vertical loop geothermal systems are ideal for projects with minimum available space. Vertical bore holes are drilled150 to 400 feet deep depending on building design considerations. A plastic polyethylene supply/return pipe is inserted into the holes and wells are connected in a parallel reverse return arrangement to allow water to circulate evenly throughout the bore field. Loop temperatures range from 37°F to 95°F. (AHRI 330 / ISO 13256-1) Horizontal Closed Loop Surface Water Closed Loop Horizontal loop geothermal systems use a series of parallel loops are installed in trenches approximately 5 feet below the ground. The piping may be installed using a “four-pipe” or “six-pipe” design. This system is well suited for applications where physical space is available – between 1,500 and 2,000 square feet/ton of cooling is required – or where bore drilling is prohibitive. (AHRI 330 / ISO 13256-1) Catalog MAMM-WHSP-PC-1UE (January 2013) Surface water closed loop geothermal systems use a loop that is directly installed in a lake or pond near the building, making it an extremely efficient and cost effective. Bundled polyethylene coils are used in a reverse return design. Care must be taken to ensure the body of water will meet building loads. Debris problems from flooding or the need for public access may limit the use of this application. (AHRI 330 / ISO 13256-1) 19 Open Loop Well Water Open loop systems use ground water to remove or add heat to the water loop and are typically used in regions where ground water is plentiful. Water is typically extracted and discharged back to the aquifer. The major benefit is the constant well water temperature, approximately 50°F, which provides very efficient operation at a relatively low installed cost. An intermediate heat exchanger is added in many cases to isolate the loop serving the units from the well water to reduce maintenance costs. This system usually has supply wells and return wells. Some states have requirements on the depths of return wells that must be approved by the U.S. Environmental Protection Agency. Water should be tested and strainers are typically required as poor water quality can increase heat exchanger scaling and suspended solids can lead to heat exchanger erosion. (AHRI 325 / ISO 13256-1) Do not locate units above noise-sensitive areas such as offices, meeting rooms, classrooms and other spaces. If possible, avoid locations above areas where there is considerable traffic as service time may be limited during occupied hours. Placing units above hallways is a typical location in schools to avoid potential noise problems with supply and return air ducted to adjacent classrooms. Such locations may limit service time during school hours. Clearance Requirements: The diagram below shows minimum suggested clearances. Any additional clearances would be beneficial, but not always necessary. Units have three access panels; one panel for the blower, one for the electrical panel and one for the compressor compartment. The requirements on any specific unit may increase or be reduced depending on several factors such as maintenance requirements and mechanical or electrical installation codes. Horizontal unit filters are removed from the right or left side with an option for bottom removal. If return air is not ducted, enough clearance will be required to provide for adequate airflow. Horizontal unit clearances Horizontal Unit Design Considerations Unit Location and Installation: Units should be positioned to provide enough clearance to perform routine maintenance or service. Units should be located for ease of filter and access panel removal. Allow the minimum clearances on each side of the unit for routine maintenance and service. Leave sufficient space on one side of the filter rack to allow filter removal. Each horizontal unit is suspended from the ceiling by four threaded rods (provided by others) fastened to the unit by a factory provided mounting bracket and rubber isolator. The unit should be located below building structural members to assure it is securely mounted in a level position. Catalog MAMM-WHSP-PC-1UE (January 2013) Piping: The unit is usually attached to the supply/ return piping using a “reverse return” arrangement. This includes a flow control device to assure proper water flow for each zone. A flexible high-pressure hose should be used to connect the system piping to the unit to simplify installation and provide sound attenuation. One end of the hose has a swivel fitting for removal of the unit for servicing. The system piping design should include supply and return shutoff valves to facilitate the removal of one unit for servicing or replacement while the system continues to operate. The return valve may be used for water flow balancing. It will 20 typically have a memory to allow it to adjust to the proper position for the required flow upon reopening. Fixed flow valves can be used to replace the memory-type valve. Providing pressure and temperature ports allows measurement of these values during operation. Condensate Drain Piping: Condensate piping can be PVC, steel or copper. PVC typically eliminates the need to insulate the pipe to prevent sweating. An O.D. factory supplied copper condensate connection (5/8” for horizontal units and ¾” for vertical units) is located outside the cabinet, allowing connection of the condensate hose. The condensate piping must be trapped (field provided). Piping must be pitched ¼ inch per foot away from the unit. Provide a vent after the trap to allow condensate to drain away from the unit. The vent also provides a clean out should the trap become obstructed. Refer to local codes for the correct condensate piping to drains. Ductwork and Sound Attenuation: Ceiling mounted heat pumps virtually always have discharge ductwork attached to the unit. A collar is provided on the discharge to facilitate attachment of the ductwork. Good design practice requires a flexible connector between the collar and transition to the main duct system. This connector attenuates sound from the unit; especially fan sound levels, and simplifies unit removal. The filter section is supplied with a bracket to accommodate return ductwork. A flexible connector should also be used to connect the unit to the return ducting to attenuate unit sound levels and allow ease of unit removal. Ducted returns are typically used on acoustically sensitive applications. Return ducting should be located at least 12 inches away from the coil to assure even distribution of return air across the coil. For applications that are especially acoustically sensitive, consider an acoustic kit that includes additional unit lining and dampening material beneath the entire unit. Ductwork should be lined with an acoustic/ thermal insulation a minimum of ½ inch. For sensitive installations, use 1-inch insulation a minimum of five to 10 feet prior to each diffuser. Changes in duct direction such as tees, elbows, and internal devices such as dampers that create airflow turbulence can increase acoustic problems. Minimize these items where possible. Placing a straight run of duct about the width between fittings will decrease turbulence and associated noise. Diffusers located in the bottom of a trunk duct pose Catalog MAMM-WHSP-PC-1UE (January 2013) acoustical problems. Volume control dampers should be placed well upstream of any air outlets. Applications that have a single duct discharge, such as hotels, should limit the velocity to a maximum of 600 fpm. These applications have a short run of discharge duct that must be fully lined with an elbow without turning vanes. Return air grilles should be located low on the sidewall and route up to the ceiling plenum. An attenuator placed at the return opening will provide added acoustical protection. ASHRAE and SMACNA Suggested Supply Air Ducting ASHRAE and SMACNA Suggested Return Air Ducting Vertical Unit Design Considerations Unit Location and Installation: Units are intended for installation in a small mechanical room or closet. The unit design minimizes sound levels to allow installation adjacent to occupied spaces. The unit is typically placed in a corner of the mechanical room or closet. The return is non-ducted and located ninety degrees to the closet door with access panels facing the door as shown in the drawings below. For application flexibility, Mammoth provides arrangements with the electrical panel, low and control voltage connections located on either side of the when facing the return air connection. Locate units for ease of filter and access panel removal. The closet door should extend past the end of the unit to allow for easy filter removal. A 21 field supplied line voltage disconnect is required for branch circuit protection. Clearance Requirements: The diagram below shows minimum suggested clearances. Any additional clearances would be beneficial, but not always necessary. Units need to be accessed on three sides; two panels for the compressor and blower, one for the electrical panel and compressor compartment. The requirements on any specific unit may increase or be reduced depending on several factors such as maintenance requirements and mechanical or electrical installation codes. Vertical unit filters are removed from the right or left side. If return air is not ducted, enough clearance will be required to provide for adequate airflow. Vertical Unit Clearances Piping: The supply and return water connections are located just above the filter to minimize the required size of the space required for units. A high pressure, flexible hose is available to connect the unit to the system hard piping to dampen the unit operating sound level. One end of the hose has a swivel fitting to allow easy removal of the unit. A deluxe hose kit is available to eliminate the need for final water balance. Provide supply and return shutoff valves to allow removal of a single unit without the need to shut down the entire system. Pressure/temperature ports should be provided to allow service personnel to monitor water flow and unit operating pressures. Ductwork and Sound Attenuation: Ductwork should conform to industry standards as listed in the ASHRAE Systems Guide. Discharge ductwork should include a non-insulated transition from the unit connection to a flexible connector at the full duct size, a short run of duct and an elbow internally lined with insulation but without turning vanes. The main duct tees into branch circuits with discharge diffusers. Return air is typically brought in through a grille in the closet door. The door should be located ninety degrees from the unit return to eliminate any “line of sight”. Return air can be brought in through the grille and ducted to the unit with internally lined acoustic insulation to a flexible connector at the unit. Sound attenuation is particularly critical at the unit return. Return ducting is facilitated through use of a filter rack that is designed to accept return air ducting. Return ducting will likely increase the required width of the closet. Catalog MAMM-WHSP-PC-1UE (January 2013) 22 Nominal Capacity – Horizontal* Cooling only and ISO 13256-1 Water Loop (Boiler/Tower Systems)1 Unit Size CFM GPM 009HHU 410 013HHU 016HHU Cooling Heating Qt Qs kW EER Qt kW COP 2.4 9,100 7,300 0.7 12.2 11,100 0.7 4.5 440 3.3 11,000 8,300 0.9 12.2 14,100 1.0 4.3 550 3.8 14,200 11,400 1.1 12.6 16,900 1.1 4.5 019HHU 700 4.5 17,400 13,100 1.3 13.0 21,500 1.4 4.6 024HHU 900 6.0 25,000 19,800 1.7 14.5 28,400 1.7 4.8 030HHU 1100 8.0 30,000 24,200 2.1 14.0 33,000 2.0 4.8 036HHU 1500 9.0 37,700 30,500 2.8 13.5 38,200 2.4 4.6 043HHU 1550 12.0 43,500 32,400 3.1 14.0 47,800 2.9 4.8 052HHU 1700 14.0 48,000 36,000 3.3 14.5 47,900 3.1 4.5 062HHU 1850 16.0 59,400 41,100 4.2 14.0 65,800 4.5 4.3 ¹ ARI/ISO 13256-1 certified capacity and efficiency - Water Loop. Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 86°F (30°C) entering water temperature. Heating capacity is based on 68°F (20°C) entering air temperature and 68°F(20°C) entering water temperature. For exact dimensional data, contact you local representative for a selection. ISO 13256-1 Ground Loop (Geothermal)2 Unit Size CFM GPM 009HLU 410 013HLU 016HLU Cooling Heating Qt Qs kW EER Qt kW COP 2.4 9,400 7,900 0.72 13.0 6,300 0.64 2.9 440 3.3 11,400 8,900 0.91 12.5 8,000 0.87 2.7 550 3.8 14,700 12,300 0.99 14.9 9,600 0.97 2.9 019HLU 700 4.5 18,000 14,100 1.27 14.2 12,300 1.16 3.1 024HLU 900 6.0 26,800 20,900 1.60 16.8 16,600 1.68 2.9 030HLU 1100 8.0 31,300 25,500 1.89 16.6 18,900 1.85 3.0 036HLU 1500 9.0 38,800 32,900 2.49 15.6 21,900 2.21 2.9 043HLU 1550 12.0 45,800 35,900 2.92 15.7 27,400 2.68 3.0 052HLU 1700 14.0 50,200 39,700 3.10 16.2 28,500 2.88 2.9 062HLU 1850 16.0 61,200 44,500 3.97 15.4 37,700 4.09 2.7 ARI/ISO 13256-1 certified capacity and efficiency - Ground Loop. Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 77°F (25°C) entering water temperature. Heating capacity is based on 68°F (20°C) entering air temperature and 32°F(0°C) entering water temperature. For exact dimensional data, contact you local representative for a selection. 2 * Please refer to Mammoth’s WSHP selection software for accurate performance at the precise entering conditions of your project. The capacity data above is provided using minimum and maximum entering water temperatures as an example only. Catalog MAMM-WHSP-PC-1UE (January 2013) 23 Nominal Capacity – Vertical* Cooling only and ISO 13256-1 Water Loop (Boiler/Tower Systems)1 Unit Size CFM GPM 012VHU 440 3.3 Cooling Heating Qt Qs kW EER Qt kW COP 11,600 8,200 0.9 12.4 12,000 0.8 4.5 024VHU 900 6.0 23,400 17,200 1.8 13.0 30,000 1.8 4.8 030VHU 1,100 8.0 27,600 20,200 2.1 13.0 35,300 2.2 4.8 036VHU 1,500 9.0 35,400 27,300 2.7 13.0 37,000 2.5 4.3 043VHU 1,550 12.0 40,200 31,100 3.1 13.0 47,000 3.2 4.3 052VHU 1,700 14.0 49,000 36,000 3.4 14.5 51,000 3.3 4.5 062VHU 1,850 16.0 59,500 42,500 4.4 13.5 66,000 4.5 4.3 ¹ ARI/ISO 13256-1 certified capacity and efficiency - Water Loop. Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 86°F (30°C) entering water temperature. Heating capacity is based on 68°F (20°C) entering air temperature and 68°F(20°C) entering water temperature. For exact dimensional data, contact you local representative for a selection. ISO 13256-1 Ground Loop (Geothermal)2 Unit Size CFM GPM 012VLU 440 024VLU 030VLU 036VLU 043VLU Cooling Heating Qt Qs kW EER Qt kW COP 3.3 11,900 8,800 0.81 14.7 7,300 0.74 2.9 900 6.0 24,100 18,100 1.64 14.7 17,200 1.80 2.8 1,100 8.0 28,400 21,200 2.00 14.2 20,200 1.97 3.0 1,500 9.0 36,400 29,800 2.56 14.2 21,900 2.21 2.9 1,550 12.0 41,400 33,600 3.16 13.1 26,900 2.92 2.7 052VLU 1,700 14.0 50,500 39,800 3.20 15.8 29,200 2.95 2.9 062VLU 1,850 16.0 63,300 46,700 4.01 15.8 38,400 4.17 2.7 ARI/ISO 13256-1 certified capacity and efficiency - Ground Loop. Cooling capacity is based on 80.6°F db, 66.2°F wb (27/19°C) entering air temperature and 77°F (25°C) entering water temperature. Heating capacity is based on 68°F (20°C) entering air temperature and 32°F(0°C) entering water temperature. For exact dimensional data, contact you local representative for a selection. 2 * Please refer to Mammoth’s WSHP selection software for accurate performance at the precise entering conditions of your project. The capacity data above is provided using minimum and maximum entering water temperatures as an example only. Catalog MAMM-WHSP-PC-1UE (January 2013) 24 Application Limits Water Temperature (°F) Standard Range Minimum Water Temperature Maximum Water Temperature Low Temperature Geothermal COOLING HEATING COOLING HEATING 500F 500F 400F 250F 0 0 110 F 0 90 F 900F 110 F Air Temperature (°F) Standard Range Minimum Ambient Air Temperature Low Temperature Geothermal COOLING HEATING COOLING HEATING 500F 500F 500F 500F Maximum Ambient Air Temperature 110 F 110 F 110 F 1100F Minimum Entering Air Temperature 650F 500F 650F 600F Maximum Entering Air Temperature 1000F 800F 1000F 900F 0 Catalog MAMM-WHSP-PC-1UE (January 2013) 0 0 25 Submittal Data – Horizontal Sizes 009 to 062, Right Hand HORIZONTAL U VINTAGE SINGLE CIRCUIT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 009H THRU 062H_U_RH RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Right hand water connections and electrical box location viewed looking into the return air duct connection. 009H THRU 062H_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV E 10/1/2012 26 1.0 [2.5cm] (X2) Submittal Data – Horizontal Sizes 009 to 062, Right Hand A (X2) 1 1/4 [3.2cm] (X2) 1.0 [2.5cm] H (X2) 3 1/4 [83.5 mm] 7/8 [22.2 mm] FOR 1/2" NOM. C ONDUIT Ø7/16 [1.1cm] (X4) G (X2) (DUCT OPENING) 2 7/8 [71.8 mm] 4 7/8 [122.6 mm] C D E (X2) F B I (X2) DETAIL A TOP VIEW J BLOWER AC CESS PANEL K M (X2) ELECT RICAL ACCESS 5/8 [1.6cm] FRONT VIEW X WAT ER OUT 1 1/2 [3.8cm] N P Q L (DUCT OPEN ING) A WAT ER IN R WAT ER CONNECT IONS (X2) DRAIN CONNECT ION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL W (DUCT OPENING) RIGHT SIDE VIEW S (DUC T OPENING) T Y U Z (D UCT OPENING) LEFT SIDE VIEW WITH END DISCHARGE V (DUCT OPENING) BACK VIE W WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H THRU 062H_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV E 10/1/2012 27 Submittal Data – Horizontal Sizes 009 to 062, Right Hand DIMENSION REFERENCE UNIT SIZE 009 013 016 in 33.4 33.4 37.3 A cm 84.8 84.8 94.7 in 30.9 30.9 35 B cm 78.5 78.5 88.9 in 19.0 19.0 20.0 C cm 48.3 48.3 50.8 in 14.6 14.6 14.9 D cm 37.1 37.1 37.9 in 17.0 17.0 17.9 E cm 43.2 43.2 45.5 in 22.1 22.1 22.8 F cm 56.1 56.1 57.9 in 16.8 16.8 21.4 G cm 42.7 42.7 54.4 in 1.5 1.5 2.3 H cm 3.8 3.8 5.8 in 3.1 3.1 2.8 I cm 7.9 7.9 7.1 in 2.9 2.9 3.0 J cm 7.4 7.4 7.6 in 1.9 1.9 1.9 K cm 4.8 4.8 4.8 in 13.4 13.4 14.1 L cm 34.1 34.1 35.8 in 0.8 0.8 0.8 M cm 2.1 2.1 2.1 in 9.8 9.8 12.0 N cm 24.9 24.9 30.5 in 1.4 1.4 1.8 P cm 3.6 3.6 4.6 in 15.0 15.0 17.4 Q cm 38.1 38.1 44.2 in 1/2 NPTF 1/2 NPTF 1/2 NPTF R cm in 6.8 6.8 8.4 S cm 17.3 17.3 21.3 in 3.4 3.4 4.4 T cm 8.6 8.6 11.2 in 3.1 3.1 5.4 U cm 7.9 7.9 13.7 in 10.3 10.3 10.4 V cm 26.2 26.2 26.4 in 6.8 6.8 8.4 W cm 17.3 17.3 21.3 in 3.4 3.4 4.4 X cm 8.6 8.6 11.2 in 1.6 1.6 1.6 Y cm 4.1 4.1 4.1 in 10.3 10.3 10.4 Z cm 26.2 26.2 26.4 AIR FI LTE R H x W (in) lb UN I T W EIG HT kg REFRIG ERAN T CH ARGE (oz ) 019 024 030 036 043 052 062 37.3 44.4 44.4 44.4 44.4 54.5 54.5 94.7 112.8 112.8 112.8 112.8 138.4 138.4 35 41.9 41.9 42.0 42.0 52.0 52.0 88.9 106.4 106.4 106.68 106.68 132.1 132.1 20.0 22.0 22.0 22.0 22.0 27.0 27.0 50.8 55.9 55.9 55.9 55.9 68.6 68.6 14.9 16.6 16.6 16.5 16.5 22.0 22.0 37.9 42.2 42.2 41.9 41.9 55.9 55.9 17.9 20.0 20.0 20.0 20.0 24.8 24.8 45.5 50.8 50.8 50.8 50.8 63.0 63.0 22.8 24.6 24.6 24.6 24.6 30.0 30.0 57.9 62.5 62.5 62.5 62.5 76.2 76.2 21.4 29.3 29.3 29.5 29.5 38.1 38.1 54.4 74.4 74.4 74.9 74.9 96.8 96.8 2.3 1.6 1.6 2.0 2.0 2.0 2.0 5.8 4.1 4.1 5.1 5.1 5.1 5.1 2.8 2.6 2.6 2.6 2.6 3.0 3.0 7.1 6.6 6.6 6.6 6.6 7.6 7.6 3.0 3.3 3.6 3.6 3.6 4.4 4.4 7.6 8.4 9.1 9.1 9.1 11.2 11.2 1.9 2.1 2.1 2.3 2.3 2.6 2.6 4.8 5.3 5.3 5.8 5.8 6.6 6.6 14.1 16.3 16.3 18.5 18.5 18.4 17.9 35.8 41.4 41.4 47.0 47.0 46.7 45.5 0.8 0.8 0.8 1.0 1.0 1.0 1.0 2.1 2.1 2.1 2.5 2.5 2.5 2.5 12.0 11.9 13.6 13.6 15.5 16.6 18.0 30.5 30.2 34.5 34.5 39.4 42.2 45.7 1.8 1.5 1.6 1.6 1.6 1.4 1.4 4.6 3.8 4.1 4.1 4.1 3.6 3.6 17.4 19.0 19.0 21.0 21.0 21.0 21.0 44.2 48.3 48.3 53.3 53.3 53.3 53.3 1/2 NPTF 1/2NPTF 3/4 NPTF 3/4 NPTF 3/4 N PTF 3/4 N PTF 1.0 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 15 x20 15x20 16x2 4 16 x24 18x30 18x3 0 20 x30 2 0x30 1 50 68 160 73 205 93 2 05 93 235 107 270 122 3 00 1 36 340 154 415 188 43 0 19 5 26 .1 27.0 30. 0 29 .9 57.0 53. 0 50 .0 6 1.4 71. 8 72. 0 009H THRU 062H_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 20x 20(2) 20 x20(2) REV E 10/1/2012 28 Submittal Data – Horizontal Sizes 009 to 062, Right Hand Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H THRU 062H_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV E 10/1/2012 29 Submittal Data – Horizontal Sizes 009 to 062, Right Hand Electrical Data - cont. Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) Unit Size Voltage 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 45 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 50 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 009 THRU 062H_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 REV E 10/1/2012 30 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with NonFused Disconnect HORIZONTAL U VINTAGE SINGLE CIRCUIT WITH NON-FUSED DISCONNECT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 009H_062H_U_RH_NFD RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Right hand water connections and electrical box location viewed looking into the return air duct connection. 009H_ 062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 6 REV B 10/23/2012 31 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect 25A Size Dim A Dim B 63A Dim C 009-013 5-5/8[143] 18-3/4[476] 14[356] Dim D Dim E Size Dim A Dim B Dim C Dim D Dim E 4-7/8[121] 11-1/8[286] 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 016-019 5-5/8[143] 19-1/2[495] 14-3/4[375] 4-1/2[175] 13-3/8[340] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] 024-030 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 036-043 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 052-062 5-1/8[130] 26-1/4[667] 21-1/2[546] 3-7/8[98] 10-1/4[260] 45A Size Dim A Dim B Dim C Dim D Dim E 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] A Dimensions are inches [millimeters] B E D C Right hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 009H_062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 6 REV B 10/23/2012 32 1.0 [2.5cm] (X2) Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect A (X2) C D E (X2) F 2 7/8 [71.8 mm] 1 1/4 [3.2cm] (X2) B 1.0 [2.5cm] 7/8 [22.2 mm] FOR 1/2" NOM. CONDUIT Ø7/16 [1.1cm] (X4) G (X2) (DUCT OPENING) H (X2) 3 1/8 [79.6 mm] I (X2) DETAIL A TOP VIEW J BLOWER ACCESS PANEL K M (X2) ELECT RICAL ACCESS 5/8 [1.6cm] FRONT VIEW X WAT ER OUT 1 1/2 [3.8cm] N P Q L (DUCT OPEN ING) A WAT ER IN R WAT ER CONNECT IONS (X2) DRAIN CONNECT ION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL W (DUCT OPENING) RIGHT SIDE VIEW S (D UCT OPENING) T Y U Z (D UCT OPENING) LEFT SIDE VIEW WITH END DISCHARGE V (DUCT OPENIN G) BACK VIE W WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H THRU 062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 6 REV B 10/23/2012 33 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect DIMENSION REFERENCE UNIT SIZE 009 013 016 in 33.4 33.4 37.3 A cm 84.8 84.8 94.7 in 30.9 30.9 35 B cm 78.5 78.5 88.9 in 19.0 19.0 20.0 C cm 48.3 48.3 50.8 in 14.6 14.6 14.9 D cm 37.1 37.1 37.9 in 17.0 17.0 17.9 E cm 43.2 43.2 45.5 in 22.1 22.1 22.8 F cm 56.1 56.1 57.9 in 16.8 16.8 21.4 G cm 42.7 42.7 54.4 in 1.5 1.5 2.3 H cm 3.8 3.8 5.8 in 3.1 3.1 2.8 I cm 7.9 7.9 7.1 in 2.9 2.9 3.0 J cm 7.4 7.4 7.6 in 1.9 1.9 1.9 K cm 4.8 4.8 4.8 in 13.4 13.4 14.1 L cm 34.1 34.1 35.8 in 0.8 0.8 0.8 M cm 2.1 2.1 2.1 in 9.8 9.8 12.0 N cm 24.9 24.9 30.5 in 1.4 1.4 1.8 P cm 3.6 3.6 4.6 in 15.0 15.0 17.4 Q cm 38.1 38.1 44.2 in 1/2 NPTF 1/2 NPTF 1/2 NPTF R cm in 6.8 6.8 8.4 S cm 17.3 17.3 21.3 in 3.4 3.4 4.4 T cm 8.6 8.6 11.2 in 3.1 3.1 5.4 U cm 7.9 7.9 13.7 in 10.3 10.3 10.4 V cm 26.2 26.2 26.4 in 6.8 6.8 8.4 W cm 17.3 17.3 21.3 in 3.4 3.4 4.4 X cm 8.6 8.6 11.2 in 1.6 1.6 1.6 Y cm 4.1 4.1 4.1 in 10.3 10.3 10.4 Z cm 26.2 26.2 26.4 AIR FI LTE R H x W (in) lb UNI T W EIG HT kg REFRIG ERANT CH ARGE (oz ) 019 024 030 036 043 052 062 37.3 44.4 44.4 44.4 44.4 54.5 54.5 94.7 112.8 112.8 112.8 112.8 138.4 138.4 35 41.9 41.9 42.0 42.0 52.0 52.0 88.9 106.4 106.4 106.68 106.68 132.1 132.1 20.0 22.0 22.0 22.0 22.0 27.0 27.0 50.8 55.9 55.9 55.9 55.9 68.6 68.6 14.9 16.6 16.6 16.5 16.5 22.0 22.0 37.9 42.2 42.2 41.9 41.9 55.9 55.9 17.9 20.0 20.0 20.0 20.0 24.8 24.8 45.5 50.8 50.8 50.8 50.8 63.0 63.0 22.8 24.6 24.6 24.6 24.6 30.0 30.0 57.9 62.5 62.5 62.5 62.5 76.2 76.2 21.4 29.3 29.3 29.5 29.5 38.1 38.1 54.4 74.4 74.4 74.9 74.9 96.8 96.8 2.3 1.6 1.6 2.0 2.0 2.0 2.0 5.8 4.1 4.1 5.1 5.1 5.1 5.1 2.8 2.6 2.6 2.6 2.6 3.0 3.0 7.1 6.6 6.6 6.6 6.6 7.6 7.6 3.0 3.3 3.6 3.6 3.6 4.4 4.4 7.6 8.4 9.1 9.1 9.1 11.2 11.2 1.9 2.1 2.1 2.3 2.3 2.6 2.6 4.8 5.3 5.3 5.8 5.8 6.6 6.6 14.1 16.3 16.3 18.5 18.5 18.4 17.9 35.8 41.4 41.4 47.0 47.0 46.7 45.5 0.8 0.8 0.8 1.0 1.0 1.0 1.0 2.1 2.1 2.1 2.5 2.5 2.5 2.5 12.0 11.9 13.6 13.6 15.5 16.6 18.0 30.5 30.2 34.5 34.5 39.4 42.2 45.7 1.8 1.5 1.6 1.6 1.6 1.4 1.4 4.6 3.8 4.1 4.1 4.1 3.6 3.6 17.4 19.0 19.0 21.0 21.0 21.0 21.0 44.2 48.3 48.3 53.3 53.3 53.3 53.3 1/2 NPTF 1/2NPTF 3/4 NPTF 3/4 NPTF 3/4 N PTF 3/4 N PTF 1.0 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 15 x20 15x20 16x2 4 16 x24 18x30 18x3 0 20 x30 2 0x30 1 50 68 160 73 205 93 2 05 93 235 107 270 122 3 00 1 36 340 154 415 188 43 0 19 5 26 .1 27.0 30. 0 29 .9 57.0 53. 0 50 .0 6 1.4 71. 8 72. 0 009H THRU 062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 6 20x 20(2) 20 x20(2) REV B 10/23/2012 34 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H THRU 062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 6 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV B 10/23/2012 35 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Non-Fused Disconnect Electrical Data - cont. Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 101.3 5.6 23.73 187/253 28.3 30 45 12.42 76.5 5.6 18.02 187/253 21.1 25 30 5.50 44.0 3.5 9.00 414/506 10.4 15 20 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 50 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 Compressor RLA LRA Unit Size Voltage 043 208-230/60/1 18.13 043 208-230/60/3 043 460/60/3 043 043 009 THRU 062H_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 6 OF 6 REV B 10/23/2012 36 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil HORIZONTAL U VINTAGE SINGLE CIRCUIT W/ WATER SIDE ECONOMIZER W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 009H THRU 062H_U_RH_WSE RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Water out to bldg. Condenser in Water out to condenser in Water in from bldg. Cross over piping Right hand water connections and electrical box location viewed looking into the return air duct connection. 009H THRU 062H_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV E 10/2/2012 37 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil A (X2) D E (X2) CC F C 1.0 [2.5 cm] (X2) 2 7/8 [71.8 mm] 1 1/8 [2.9cm] (X2) B 4 7/8 [122.6 mm] 1.0 [2.5cm] (X2) 3 1/4 [83.5 mm] Ø7/16 [1.1cm] (X4) 7/8 FOR 1/2" 3 1/4 [8.3cm] (X2) LINE VOLTAGE CONDUI T CONNECTI ON G (X2) (DUCT OPENING) H (X2) BB (X2) DETAIL A AA TOP VIEW HH WATER CONNECTIONS L (X2) (DUCT OPENING) J M (X2) FF CONDUIT (X2) K DD N EE A Ø5/8 [1.6cm] (X2) DRAIN CONNECTION Ø5/8 [1.6cm] NOMINAL FRONT VIEW R WATER CONNECTIONS (X2) DRAIN CONNECTION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL P GG RIGHT SIDE VIEW X W (DUCT OPENING) S T (DUCT OPENING) Y U Z (DUCT OPENING) V (DUCT OPENING) LEFT SIDE VIEW WITH END DISCHARGE REAR VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H THRU 062H_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV E 10/2/2012 38 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil DIMENS ION REFERENCE UN IT SIZE A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in A IR F I LTE R H x W ( in ) U N IT lb W EI G HT kg RE F RI G ERA N T C HA R G E ( o z) 009 33.4 84.8 30.9 78.5 19.0 48.3 14.6 37.1 17.0 43.2 26.1 66.3 17.4 44.2 0.0 0.0 2.9 7.4 1.9 4.8 13.3 33.8 0.8 2.1 9.8 24.9 1.4 3.6 15.0 38.1 1/2 NPTF 6.8 17.3 3.4 8.6 3.1 7.9 10.3 26.2 6.8 17.3 3.4 8.6 1.6 4.1 10.3 26.2 9.7 24.6 19.4 49.3 11.9 30.2 7.8 19.8 12.5 31.8 0.9 2.3 20.2 51.3 1/2 NPTF 013 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 0 16 37.3 94.7 35 88.9 20.0 50.8 14.9 37.9 17.9 45.5 26.8 68 21 53.3 0.4 1 3.0 7.6 1.9 4.8 14.2 36.1 0.8 2.1 12.0 30.5 1.8 4.6 17.4 44.2 1/2 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.8 24.9 23.3 59.2 12.7 32.3 9 22.9 15.1 38.4 1.7 4.3 23.8 60.5 1/2 NPTF 019 3 7.3 9 4.7 35 8 8.9 2 0.0 5 0.8 1 4.9 3 7.9 1 7.9 4 5.5 2 6.8 68 21 5 3.3 0.4 1 3.0 7.6 1.9 4.8 1 4.2 3 6.1 0.8 2.1 1 2.0 3 0.5 1.8 4.6 1 7.4 4 4.2 1/2 NPTF 8.4 2 1.3 4.4 1 1.2 5.4 1 3.7 1 0.4 2 6.4 8.4 2 1.3 4.4 1 1.2 1.6 4.1 1 0.4 2 6.4 9.8 2 4.9 2 3.3 5 9.2 1 2.7 3 2.3 9 2 2.9 1 5.1 3 8.4 1.7 4.3 2 3.8 6 0.5 1/2 NPTF 02 4 44.4 11 2.8 41.9 10 6.4 22.0 55.9 16.6 42.2 20.0 50.8 28.8 73.2 28.5 72.4 0 .4 1 3 .3 8 .4 2 .1 5 .3 16.2 41.2 0 .8 2 .1 11.9 30.2 1 .5 3 .8 19.0 48.3 1 /2 NP TF 9 .1 23.1 4 .4 11.2 6 .0 15.2 10.1 25.7 9 .1 23.1 4 .4 11.2 2 .9 7 .4 10.1 25.7 9 .8 24.9 30.9 78.5 13.1 33.3 10.5 26.7 17.5 44.5 1 .4 3 .6 31.3 79.5 3 /4 NP TF 0 30 44.4 1 12.8 41.9 1 06.4 22.0 55.9 16.6 42.2 20.0 50.8 28.8 73.2 28.5 72.4 0.4 1 3.6 9.1 2.1 5.3 16.2 41.2 0.8 2.1 13.6 34.5 1.6 4.1 19.0 48.3 3/4 NPTF 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.8 24.9 30.9 78.5 13.1 33.3 10.5 26.7 17.5 44.5 1.4 3.6 31.3 79.5 3/4 NPTF 036 44.4 112.8 42.0 106.68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 13.6 34.5 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 043 44.4 112.8 42.0 106 .68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 15.5 39.4 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 15 x 17 15x 17 1 6x 21 16x 2 1 18x 28 18 x 28 20x 27. 5 20x 27.5 1 74 79 184 83 255 116 255 116 285 129 3 20 1 45 390 177 390 177 26. 1 27.0 3 0.0 29. 9 57.0 53. 0 50.0 6 1.4 009H THRU 062H_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 052 54 .5 138.4 52 .0 132.1 27 .0 68 .6 22 .0 55 .9 24 .8 63 .0 34 .4 87 .4 37 .5 95 .2 1.1 2.8 4.4 11 .2 2.6 6.6 18 .3 46 .5 1.0 2.5 16 .6 42 .2 1.4 3.6 21 .0 53 .3 3 /4 NP TF 12 .6 32 .1 4.5 11 .4 8.1 20 .6 11 .4 28 .9 12 .6 32 .0 4.5 11 .4 1.5 3.8 11 .4 28 .9 9.7 24 .6 37 .5 95 .2 13 .3 33 .8 10 .8 27 .4 19 .4 49 .3 1.4 3.6 41 104.1 3 /4 NP TF 0 62 54.5 1 38.4 52.0 1 32.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1.1 2.8 4.4 11.2 2.6 6.6 18.3 46.5 1.0 2.5 18.0 45.7 1.4 3.6 21.0 53.3 1.0 NP TF 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 9.7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1.4 3.6 41 1 04.1 1.0 NP TF 18x 20( 1) , 18x 20( 1) , 20x 20( 1) 20 x 20( 1) 515 530 234 240 71. 8 REV E 72.0 10/2/2012 39 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H THRU 062H_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV E 10/2/2012 40 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 45 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 50 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 Compressor 009 THRU 062H_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 REV E 10/2/2012 41 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect W A TE R S O UR C E H E A T P U M P HORIZONTAL U VINTAGE W/ WATER SIDE ECONOMIZER AND NON-FUSED DISCONNECT SUBMITTAL PACKAGE 009H_062H_U_RH_WSE_NFD RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Water out to bldg. Condenser in Water out to condenser in Water in from bldg. Cross over piping Right hand water connections and electrical box location viewed looking into the return air duct connection. 009H_ 062H_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 6 REV A 10/23/2012 42 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect 25A Size Dim A Dim B 63A Dim C 009-013 5-5/8[143] 18-3/4[476] 14[356] Dim D Dim E Size Dim A Dim B Dim C Dim D Dim E 4-7/8[121] 11-1/8[286] 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 016-019 5-5/8[143] 19-1/2[495] 14-3/4[375] 4-1/2[175] 13-3/8[340] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] 024-030 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 036-043 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 052-062 5-1/8[130] 26-1/4[667] 21-1/2[546] 3-7/8[98] 10-1/4[260] 45A Size Dim A Dim B Dim C Dim D Dim E 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] A Dimensions are inches [millimeters] D E B C Right hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 009H_062H_U_RH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 6 REV B 10/23/2012 43 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect A (X2) 1 1/8 [2.9cm] (X2) D E (X2) B 2 7/8 [71.8 mm] 1.0 [2.5cm] (X2) F C 1.0 [2.5 cm] (X2) CC Ø7/16 [1.1cm] (X4) 3 1/4 [8.3cm] (X2) 3 1/8 [79.6 mm] 7/8 [22.2 mm] FOR 1/2" NOM. CONDUIT G (X2) (DUCT OPENING) H (X2) BB (X2) DETAIL A AA TOP VIEW HH WATER CONNECTIONS L (X2) (DUCT OPENING) J M (X2) FF K DD N EE A Ø5/8 [1.6cm] (X2) DRAIN CONNECTION Ø5/8 [1.6cm] NOMINAL FRONT VIEW R WATER CONNECTIONS (X2) DRAIN CONNECTION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL P GG RIGHT SIDE VIEW X W (DUCT OPENING) S T (DUCT OPENING) Y U Z (DUCT OPENING) V (DUCT OPENING) LEFT SIDE VIEW WITH END DISCHARGE REAR VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H_062H_U_RH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 6 REV A 10/23/2012 44 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect DIMENS ION REFERENCE UN IT SIZE A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in A IR F I LTE R H x W ( in ) U N IT lb W EI G HT kg RE F RI G ERA N T C HA R G E ( o z) 009 33.4 84.8 30.9 78.5 19.0 48.3 14.6 37.1 17.0 43.2 26.1 66.3 17.4 44.2 0.0 0.0 2.9 7.4 1.9 4.8 13.3 33.8 0.8 2.1 9.8 24.9 1.4 3.6 15.0 38.1 1/2 NPTF 6.8 17.3 3.4 8.6 3.1 7.9 10.3 26.2 6.8 17.3 3.4 8.6 1.6 4.1 10.3 26.2 9.7 24.6 19.4 49.3 11.9 30.2 7.8 19.8 12.5 31.8 0.9 2.3 20.2 51.3 1/2 NPTF 013 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 0 16 37.3 94.7 35 88.9 20.0 50.8 14.9 37.9 17.9 45.5 26.8 68 21 53.3 0.4 1 3.0 7.6 1.9 4.8 14.2 36.1 0.8 2.1 12.0 30.5 1.8 4.6 17.4 44.2 1/2 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.8 24.9 23.3 59.2 12.7 32.3 9 22.9 15.1 38.4 1.7 4.3 23.8 60.5 1/2 NPTF 019 3 7.3 9 4.7 35 8 8.9 2 0.0 5 0.8 1 4.9 3 7.9 1 7.9 4 5.5 2 6.8 68 21 5 3.3 0.4 1 3.0 7.6 1.9 4.8 1 4.2 3 6.1 0.8 2.1 1 2.0 3 0.5 1.8 4.6 1 7.4 4 4.2 1/2 NPTF 8.4 2 1.3 4.4 1 1.2 5.4 1 3.7 1 0.4 2 6.4 8.4 2 1.3 4.4 1 1.2 1.6 4.1 1 0.4 2 6.4 9.8 2 4.9 2 3.3 5 9.2 1 2.7 3 2.3 9 2 2.9 1 5.1 3 8.4 1.7 4.3 2 3.8 6 0.5 1/2 NPTF 02 4 44.4 11 2.8 41.9 10 6.4 22.0 55.9 16.6 42.2 20.0 50.8 28.8 73.2 28.5 72.4 0 .4 1 3 .3 8 .4 2 .1 5 .3 16.2 41.2 0 .8 2 .1 11.9 30.2 1 .5 3 .8 19.0 48.3 1 /2 NP TF 9 .1 23.1 4 .4 11.2 6 .0 15.2 10.1 25.7 9 .1 23.1 4 .4 11.2 2 .9 7 .4 10.1 25.7 9 .8 24.9 30.9 78.5 13.1 33.3 10.5 26.7 17.5 44.5 1 .4 3 .6 31.3 79.5 3 /4 NP TF 0 30 44.4 1 12.8 41.9 1 06.4 22.0 55.9 16.6 42.2 20.0 50.8 28.8 73.2 28.5 72.4 0.4 1 3.6 9.1 2.1 5.3 16.2 41.2 0.8 2.1 13.6 34.5 1.6 4.1 19.0 48.3 3/4 NPTF 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.8 24.9 30.9 78.5 13.1 33.3 10.5 26.7 17.5 44.5 1.4 3.6 31.3 79.5 3/4 NPTF 036 44.4 112.8 42.0 106.68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 13.6 34.5 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 043 44.4 112.8 42.0 106 .68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 15.5 39.4 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 15 x 17 15x 17 1 6x 21 16x 2 1 18x 28 18 x 28 20x 27. 5 20x 27.5 1 74 79 184 83 255 116 255 116 285 129 3 20 1 45 390 177 390 177 26. 1 27.0 3 0.0 29. 9 57.0 53. 0 50.0 6 1.4 009H_ 062H_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 6 052 54 .5 138.4 52 .0 132.1 27 .0 68 .6 22 .0 55 .9 24 .8 63 .0 34 .4 87 .4 37 .5 95 .2 1.1 2.8 4.4 11 .2 2.6 6.6 18 .3 46 .5 1.0 2.5 16 .6 42 .2 1.4 3.6 21 .0 53 .3 3 /4 NP TF 12 .6 32 .1 4.5 11 .4 8.1 20 .6 11 .4 28 .9 12 .6 32 .0 4.5 11 .4 1.5 3.8 11 .4 28 .9 9.7 24 .6 37 .5 95 .2 13 .3 33 .8 10 .8 27 .4 19 .4 49 .3 1.4 3.6 41 104.1 3 /4 NP TF 0 62 54.5 1 38.4 52.0 1 32.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1.1 2.8 4.4 11.2 2.6 6.6 18.3 46.5 1.0 2.5 18.0 45.7 1.4 3.6 21.0 53.3 1.0 NP TF 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 9.7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1.4 3.6 41 1 04.1 1.0 NP TF 18x 20( 1) , 18x 20( 1) , 20x 20( 1) 20 x 20( 1) 515 530 234 240 71. 8 REV A 72.0 10/23/2012 45 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H_ 062H_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 6 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV A 10/23/2012 46 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 45 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 50 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 60 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 009_062H_U_RH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 6 OF 6 REV A 10/23/2012 47 Submittal Data – Horizontal Sizes 009 to 062, Left Hand HORIZONTAL U VINTAGE SINGLE CIRCUIT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 009H THRU 062H_U_LH LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 009H THRU 062H_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV E 10/1/2012 48 1 1/4 [3.2cm] (X2) B E (X2) C 1.0 [2.5cm] F 1.0 [2.5cm] (X2) A (X2) D 3 1/4 [83.5 mm] 4 7/8 [122.3 mm] 2 7/8 [71.5 mm] Submittal Data – Horizontal Sizes 009 to 062, Left Hand 7/8 FOR 1/2" NOM. CONDUIT (X2) LINE VOLTAGE CONDUIT CONNEC TION Ø7/16 [1.1cm] (X4) DETAIL A I (X2) G (X2) (D UCT OPENING) H (X2) TOP VIEW J K BLOWER ACC ESS PANEL WAT ER IN R WATER CONNECTIONS (X2) COMPRESSOR ACCESS PANEL Q N 1 1/2 [3.8cm] A P WATER OUT L (DUCT OPENING) M (X2) FRONT VIEW LEFT SIDE VIEW T ELECTRICAL ACCESS S (DUCT OPEN ING) W (D UCT OPENING) X U Y Z (DUCT OPENING) V (D UCT OPENING) RIGHT SIDE VIEW WITH END DISCHARGE BACK VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H THRU 062H_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV E 10/1/2012 49 Submittal Data – Horizontal Sizes 009 to 062, Left Hand DIMENSION REFERENCE UNIT SIZE 009 013 016 in 33.4 33.4 37.3 A cm 84.8 84.8 94.7 in 30.9 30.9 35 B cm 78.5 78.5 88.9 in 19.0 19.0 20.0 C cm 48.3 48.3 50.8 in 14.6 14.6 14.9 D cm 37.1 37.1 37.9 in 17.0 17.0 17.9 E cm 43.2 43.2 45.5 in 22.1 22.1 22.8 F cm 56.1 56.1 57.9 in 16.8 16.8 21.4 G cm 42.7 42.7 54.4 in 1.5 1.5 2.3 H cm 3.8 3.8 5.8 in 3.1 3.1 2.8 I cm 7.9 7.9 7.1 in 2.9 2.9 3.0 J cm 7.4 7.4 7.6 in 1.9 1.9 1.9 K cm 4.8 4.8 4.8 in 13.4 13.4 14.1 L cm 34.1 34.1 35.8 in 0.8 0.8 0.8 M cm 2.1 2.1 2.1 in 9.8 9.8 12.0 N cm 24.9 24.9 30.5 in 1.4 1.4 1.8 P cm 3.6 3.6 4.6 in 15.0 15.0 17.4 Q cm 38.1 38.1 44.2 in 1/2 NPTF 1/2 NPTF 1/2 NPTF R cm in 6.8 6.8 8.4 S cm 17.3 17.3 21.3 in 3.4 3.4 4.4 T cm 8.6 8.6 11.2 in 3.1 3.1 5.4 U cm 7.9 7.9 13.7 in 10.3 10.3 10.4 V cm 26.2 26.2 26.4 in 6.8 6.8 8.4 W cm 17.3 17.3 21.3 in 3.4 3.4 4.4 X cm 8.6 8.6 11.2 in 1.6 1.6 1.6 Y cm 4.1 4.1 4.1 in 10.3 10.3 10.4 Z cm 26.2 26.2 26.4 AI R FI LT ER H x W (in ) UNIT lb W E IG HT k g REFRI GE RAN T CH ARG E (o z ) 019 024 030 036 043 052 062 37.3 44.4 44.4 44.4 44.4 54.5 54.5 94.7 112.8 112.8 112.8 112.8 138.4 138.4 35 41.9 41.9 42.0 42.0 52.0 52.0 88.9 106.4 106.4 106.68 106.68 132.1 132.1 20.0 22.0 22.0 22.0 22.0 27.0 27.0 50.8 55.9 55.9 55.9 55.9 68.6 68.6 14.9 16.6 16.6 16.5 16.5 22.0 22.0 37.9 42.2 42.2 41.9 41.9 55.9 55.9 17.9 20.0 20.0 20.0 20.0 24.8 24.8 45.5 50.8 50.8 50.8 50.8 63.0 63.0 22.8 24.6 24.6 24.6 24.6 30.0 30.0 57.9 62.5 62.5 62.5 62.5 76.2 76.2 21.4 29.3 29.3 29.5 29.5 38.1 38.1 54.4 74.4 74.4 74.9 74.9 96.8 96.8 2.3 1.6 1.6 2.0 2.0 2.0 2.0 5.8 4.1 4.1 5.1 5.1 5.1 5.1 2.8 2.6 2.6 2.6 2.6 3.0 3.0 7.1 6.6 6.6 6.6 6.6 7.6 7.6 3.0 3.3 3.6 3.6 3.6 4.4 4.4 7.6 8.4 9.1 9.1 9.1 11.2 11.2 1.9 2.1 2.1 2.3 2.3 2.6 2.6 4.8 5.3 5.3 5.8 5.8 6.6 6.6 14.1 16.3 16.3 18.5 18.5 18.4 17.9 35.8 41.4 41.4 47.0 47.0 46.7 45.5 0.8 0.8 0.8 1.0 1.0 1.0 1.0 2.1 2.1 2.1 2.5 2.5 2.5 2.5 12.0 11.9 13.6 13.6 15.5 16.6 18.0 30.5 30.2 34.5 34.5 39.4 42.2 45.7 1.8 1.5 1.6 1.6 1.6 1.4 1.4 4.6 3.8 4.1 4.1 4.1 3.6 3.6 17.4 19.0 19.0 21.0 21.0 21.0 21.0 44.2 48.3 48.3 53.3 53.3 53.3 53.3 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NP TF 3/4 NPTF 1.0 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 15 x2 0 15 x20 16 x24 16 x24 18x 30 18x 30 2 0x3 0 2 0x3 0 1 50 68 1 60 73 2 05 93 20 5 93 23 5 10 7 27 0 12 2 30 0 13 6 340 154 415 188 4 30 1 95 2 6.1 27 .0 30 .0 29 .9 57 .0 53. 0 50. 0 6 1. 4 7 1. 8 7 2.0 009H THRU 062H_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 2 0x2 0(2 ) 20 x2 0(2) REV E 10/1/2012 50 Submittal Data – Horizontal Sizes 009 to 062, Left Hand Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H THRU 062H_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV E 10/1/2012 51 Submittal Data – Horizontal Sizes 009 to 062, Left Hand Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 45 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 50 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage 062 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 009 THRU 062H_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 REV E 10/1/2012 52 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with NonFused Disconnect HORIZONTAL U VINTAGE SINGLE CIRCUIT WITH NON-FUSED DISCONNECT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 009H_062H_U_LH_NFD LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 009H_ 062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 6 REV B 10/22/2012 53 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect 25A Size Dim A Dim B 63A Dim C 009-013 5-5/8[143] 18-3/4[476] 14[356] Dim D Dim E Size Dim A Dim B Dim C Dim D Dim E 4-7/8[121] 11-1/8[286] 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 016-019 5-5/8[143] 19-1/2[495] 14-3/4[375] 4-1/2[175] 13-3/8[340] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] 024-030 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 036-043 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 052-062 5-1/8[130] 26-1/4[667] 21-1/2[546] 3-7/8[98] 10-1/4[260] 45A Size Dim A Dim B Dim C Dim D Dim E 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] A Dimensions are inches [millimet ers] B E D C Left hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 009H_062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 6 REV B 10/22/2012 54 A (X2) 2 7/8 [71.6 mm] B E (X2) C 1.0 [2.5cm] F 1 1/4 [3.2cm] (X2) D 3 1/8 [79.6 mm] 1.0 [2.5cm] (X2) Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect 7/8 [22.2 mm] FOR 1/2" NOM. CONDUIT Ø7/16 [1.1cm] (X4) DETAIL A I (X2) G (X2) (D UCT OPENING) H (X2) TOP VIEW J K BLOWER ACCESS PANEL WAT ER IN R WATER CONNECTIONS (X2) Q N 1 1/2 [3.8cm] A P WATER OUT L (DUCT OPENING) M (X2) COMPRESSOR ACCESS PANEL ELECTRICAL ACCESS FRONT VIEW LEFT SIDE VIEW T S (DUCT OPEN ING) W (D UCT OPENING) X U Y Z (DUCT OPENING) V (D UCT OPENING) RIGHT SIDE VIEW WITH END DISCHARGE BACK VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H_062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 6 REV B 10/22/2012 55 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect DIMENSION REFERENCE UNIT SIZE 009 013 016 in 33.4 33.4 37.3 A cm 84.8 84.8 94.7 in 30.9 30.9 35 B cm 78.5 78.5 88.9 in 19.0 19.0 20.0 C cm 48.3 48.3 50.8 in 14.6 14.6 14.9 D cm 37.1 37.1 37.9 in 17.0 17.0 17.9 E cm 43.2 43.2 45.5 in 22.1 22.1 22.8 F cm 56.1 56.1 57.9 in 16.8 16.8 21.4 G cm 42.7 42.7 54.4 in 1.5 1.5 2.3 H cm 3.8 3.8 5.8 in 3.1 3.1 2.8 I cm 7.9 7.9 7.1 in 2.9 2.9 3.0 J cm 7.4 7.4 7.6 in 1.9 1.9 1.9 K cm 4.8 4.8 4.8 in 13.4 13.4 14.1 L cm 34.1 34.1 35.8 in 0.8 0.8 0.8 M cm 2.1 2.1 2.1 in 9.8 9.8 12.0 N cm 24.9 24.9 30.5 in 1.4 1.4 1.8 P cm 3.6 3.6 4.6 in 15.0 15.0 17.4 Q cm 38.1 38.1 44.2 in 1/2 NPTF 1/2 NPTF 1/2 NPTF R cm in 6.8 6.8 8.4 S cm 17.3 17.3 21.3 in 3.4 3.4 4.4 T cm 8.6 8.6 11.2 in 3.1 3.1 5.4 U cm 7.9 7.9 13.7 in 10.3 10.3 10.4 V cm 26.2 26.2 26.4 in 6.8 6.8 8.4 W cm 17.3 17.3 21.3 in 3.4 3.4 4.4 X cm 8.6 8.6 11.2 in 1.6 1.6 1.6 Y cm 4.1 4.1 4.1 in 10.3 10.3 10.4 Z cm 26.2 26.2 26.4 AI R FI LT ER H x W (in ) UNIT lb W E IG HT k g REFRI GE RAN T CH ARG E (o z ) 019 024 030 036 043 052 062 37.3 44.4 44.4 44.4 44.4 54.5 54.5 94.7 112.8 112.8 112.8 112.8 138.4 138.4 35 41.9 41.9 42.0 42.0 52.0 52.0 88.9 106.4 106.4 106.68 106.68 132.1 132.1 20.0 22.0 22.0 22.0 22.0 27.0 27.0 50.8 55.9 55.9 55.9 55.9 68.6 68.6 14.9 16.6 16.6 16.5 16.5 22.0 22.0 37.9 42.2 42.2 41.9 41.9 55.9 55.9 17.9 20.0 20.0 20.0 20.0 24.8 24.8 45.5 50.8 50.8 50.8 50.8 63.0 63.0 22.8 24.6 24.6 24.6 24.6 30.0 30.0 57.9 62.5 62.5 62.5 62.5 76.2 76.2 21.4 29.3 29.3 29.5 29.5 38.1 38.1 54.4 74.4 74.4 74.9 74.9 96.8 96.8 2.3 1.6 1.6 2.0 2.0 2.0 2.0 5.8 4.1 4.1 5.1 5.1 5.1 5.1 2.8 2.6 2.6 2.6 2.6 3.0 3.0 7.1 6.6 6.6 6.6 6.6 7.6 7.6 3.0 3.3 3.6 3.6 3.6 4.4 4.4 7.6 8.4 9.1 9.1 9.1 11.2 11.2 1.9 2.1 2.1 2.3 2.3 2.6 2.6 4.8 5.3 5.3 5.8 5.8 6.6 6.6 14.1 16.3 16.3 18.5 18.5 18.4 17.9 35.8 41.4 41.4 47.0 47.0 46.7 45.5 0.8 0.8 0.8 1.0 1.0 1.0 1.0 2.1 2.1 2.1 2.5 2.5 2.5 2.5 12.0 11.9 13.6 13.6 15.5 16.6 18.0 30.5 30.2 34.5 34.5 39.4 42.2 45.7 1.8 1.5 1.6 1.6 1.6 1.4 1.4 4.6 3.8 4.1 4.1 4.1 3.6 3.6 17.4 19.0 19.0 21.0 21.0 21.0 21.0 44.2 48.3 48.3 53.3 53.3 53.3 53.3 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NP TF 3/4 NPTF 1.0 NPTF 8.4 21.3 4.4 11.2 5.4 13.7 10.4 26.4 8.4 21.3 4.4 11.2 1.6 4.1 10.4 26.4 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 9.1 23.1 4.4 11.2 6.0 15.2 10.1 25.7 9.1 23.1 4.4 11.2 2.9 7.4 10.1 25.7 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 15 x2 0 15 x20 16 x24 16 x24 18x 30 18x 30 2 0x3 0 2 0x3 0 1 50 68 1 60 73 2 05 93 20 5 93 23 5 10 7 27 0 12 2 30 0 13 6 340 154 415 188 4 30 1 95 2 6.1 27 .0 30 .0 29 .9 57 .0 53. 0 50. 0 6 1. 4 7 1. 8 7 2.0 009H_ 062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 6 2 0x2 0(2 ) 20 x2 0(2) REV B 10/22/2012 56 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H_ 062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 6 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV B 10/22/2012 57 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Non-Fused Disconnect Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 45 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 50 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 009_062H_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 6 OF 6 REV B 10/22/2012 58 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil HORIZONTAL U VINTAGE SINGLE CIRCUIT W/ WATER SIDE ECONOMIZER W A TE R S O U RC E H E A T P U M P SUBMITTAL PACKAGE 009H THRU 062H_U_LH_WSE LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Water out to bldg. Water out to Condenser in Condenser in Cross over piping Water in from bldg. Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 009H THRU 062H_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV E 10/2/2012 59 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil 1.0 [2.5cm] (X2) A (X2) E (X2) CC Ø7/16 [1.1cm] (X4) 7/8 OR 1/2" LINE VOLTAGE CONDUIT CONNECTION CONDU IT (X2) WAT ER SIDE ECONOMIZER G (DU CT OPENING) DETAIL A F 1.0 [2.5cm] (X2) C 2 7/8 [74.24 mm] B D 2 7/8 [71.85 mm] 4 7/8 [122.65 mm] 1 1/8 [2.9cm] (X2) 3 1/4 [8.3 cm](x2) H (X2) AA BB (X2) TOP VIEW J HH WATER CONNECTION S (X2) K FF L (DUCT OPENIN G) DD N EE Q M (X2) A P 5/8 [1.6cm] (X2) R WATER C ONNECTIONS (X2) DRAIN CONN ECT ION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL D RAIN CONNECTION Ø5/8 [1.6cm] NOMINAL FRONT VIEW LEFT SIDE VIEW W (DUCT OPENING) S (DUCT OPENING) T BLOWER ACCESS PANEL GG X U Y Z (DUCT OPENING) V (DUCT OPENING) RIGHT SIDE VIEW WITH END DISCHARGE REAR VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H THRU 062H_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV E 10/2/2012 60 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil DIMENSION REFERENCE UNIT SIZE A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in A IR F IL TER H x W ( i n) UNIT lb W EIG H T k g R EF R IG ER A N T C HA R G E (o z ) 009 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 013 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 016 37 .3 94 .7 35 88 .9 20 .0 50 .8 14 .9 37 .9 17 .9 45 .5 26 .8 68 21 53 .3 0.4 1 3.0 7.6 1.9 4.8 14 .2 36 .1 0.8 2.1 12 .0 30 .5 1.8 4.6 17 .4 44 .2 1 /2 NPTF 8.4 21 .3 4.4 11 .2 5.4 13 .7 10 .4 26 .4 8.4 21 .3 4.4 11 .2 1.6 4.1 10 .4 26 .4 9.8 24 .9 23 .3 59 .2 12 .7 32 .3 9 22 .9 15 .1 38 .4 1.7 4.3 23 .8 60 .5 1 /2 NPTF 01 9 3 7.3 9 4.7 35 8 8.9 2 0.0 5 0.8 1 4.9 3 7.9 1 7.9 4 5.5 2 6.8 68 21 5 3.3 0 .4 1 3 .0 7 .6 1 .9 4 .8 1 4.2 3 6.1 0 .8 2 .1 1 2.0 3 0.5 1 .8 4 .6 1 7.4 4 4.2 1/2 NP TF 8 .4 2 1.3 4 .4 1 1.2 5 .4 1 3.7 1 0.4 2 6.4 8 .4 2 1.3 4 .4 1 1.2 1 .6 4 .1 1 0.4 2 6.4 9 .8 2 4.9 2 3.3 5 9.2 1 2.7 3 2.3 9 2 2.9 1 5.1 3 8.4 1 .7 4 .3 2 3.8 6 0.5 1/2 NP TF 024 4 4.4 112 .8 4 1.9 106 .4 2 2.0 5 5.9 1 6.6 4 2.2 2 0.0 5 0.8 2 8.8 7 3.2 2 8.5 7 2.4 0.4 1 3.3 8.4 2.1 5.3 1 6.2 4 1.2 0.8 2.1 1 1.9 3 0.2 1.5 3.8 1 9.0 4 8.3 1/2 NPTF 9.1 2 3.1 4.4 1 1.2 6.0 1 5.2 1 0.1 2 5.7 9.1 2 3.1 4.4 1 1.2 2.9 7.4 1 0.1 2 5.7 9.8 2 4.9 3 0.9 7 8.5 1 3.1 3 3.3 1 0.5 2 6.7 1 7.5 4 4.5 1.4 3.6 3 1.3 7 9.5 3/4 NPTF 030 44 .4 112 .8 41 .9 106 .4 22 .0 55 .9 16 .6 42 .2 20 .0 50 .8 28 .8 73 .2 28 .5 72 .4 0.4 1 3.6 9.1 2.1 5.3 16 .2 41 .2 0.8 2.1 13 .6 34 .5 1.6 4.1 19 .0 48 .3 3/4 NPTF 9.1 23 .1 4.4 11 .2 6.0 15 .2 10 .1 25 .7 9.1 23 .1 4.4 11 .2 2.9 7.4 10 .1 25 .7 9.8 24 .9 30 .9 78 .5 13 .1 33 .3 10 .5 26 .7 17 .5 44 .5 1.4 3.6 31 .3 79 .5 3/4 NPTF 036 44 .4 112.8 42 .0 106.6 8 22 .0 55 .9 16 .5 41 .9 20 .0 50 .8 29 .4 74 .7 28 .5 72 .4 .4 1 3.6 9.1 2.3 5.8 18 .2 46 .2 1.0 2.5 13 .6 34 .5 1.6 4.1 21 .0 53 .3 3/4 NPTF 10 .0 25 .4 3.6 9.1 7.9 20 .1 11 .4 28 .9 10 .0 25 .4 3.5 8.9 1.8 4.6 11 .4 28 .9 9.3 23 .6 30 .9 78 .5 13 .3 33 .8 10 .6 26 .9 19 .4 49 .3 1.5 3.8 31 .3 79 .5 3/4 NPTF 0 43 44.4 1 12.8 42.0 106.68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 15.5 39.4 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 15x 1 7 15x 17 1 6x 21 16x 21 18x 2 8 18x 28 2 0x 27. 5 20x 27 .5 174 79 18 4 83 255 116 255 116 285 129 32 0 14 5 390 177 390 177 26. 1 27. 0 30 .0 29.9 57. 0 53. 0 5 0.0 61.4 009H THRU 062H_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 05 2 54.5 13 8.4 52.0 13 2.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1 .1 2 .8 4 .4 11.2 2 .6 6 .6 18.3 46.5 1 .0 2 .5 16.6 42.2 1 .4 3 .6 21.0 53.3 3/4 NPTF 12.6 32.1 4 .5 11.4 8 .1 20.6 11.4 28.9 12.6 32.0 4 .5 11.4 1 .5 3 .8 11.4 28.9 9 .7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1 .4 3 .6 41 10 4.1 3/4 NPTF 0 62 54.5 1 38.4 52.0 1 32.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1.1 2.8 4.4 11.2 2.6 6.6 18.3 46.5 1.0 2.5 18.0 45.7 1.4 3.6 21.0 53.3 1 .0 NPTF 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 9.7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1.4 3.6 41 1 04.1 1 .0 NPTF 18 x 20( 1) , 18x 20 ( 1) , 20x 20( 1 ) 20x 2 0( 1) 515 5 30 234 2 40 71. 8 REV E 72 .0 10/2/2012 61 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H THRU 062H_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV E 10/2/2012 62 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 45 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 052 208-230/60/1 20.29 9.2 29.49 187/253 34.6 35 50 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 105.8 Compressor 009 THRU 062H_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 REV E 10/2/2012 63 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect HORIZONTAL U VINTAGE W/ WATER SIDE ECONOMIZER AND NON-FUSED DISCONNECT W A TE R S O U RC E H E A T P U M P SUBMITTAL PACKAGE 009H_062H_U_LH_WSE_NFD LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Water out to bldg. Water out to Condenser in Condenser in Cross over piping Water in from bldg. Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 009H_ 062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 6 REV A 10/23/2012 64 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect 25A Size Dim A Dim B 63A Dim C 009-013 5-5/8[143] 18-3/4[476] 14[356] Dim D Dim E Size Dim A Dim B Dim C Dim D Dim E 4-7/8[121] 11-1/8[286] 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 016-019 5-5/8[143] 19-1/2[495] 14-3/4[375] 4-1/2[175] 13-3/8[340] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] 024-030 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 036-043 5-1/8[130] 21-1/4[540] 16-1/2[368] 3-7/8[98] 10-1/4[260] 052-062 5-1/8[130] 26-1/4[667] 21-1/2[546] 3-7/8[98] 10-1/4[260] 45A Size Dim A Dim B Dim C Dim D Dim E 036-043 5-5/8[143] 21-7/8[556] 15-1/2[394] 5-1/2[140] 13-1/8[333] 052-062 5-5/8[143] 26-7/8[683] 20-1/2[521] 5-1/2[140] 13-1/8[333] A Dimensions are inches [millimet ers] E C D B Left hand non-fused disc onnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 009H_062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 6 REV A 10/23/2012 65 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect 1.0 [2.5cm] (X2) C Ø7/16 [1.1cm] (X4) CC 7/8 [22.23 mm] FOR 1/2" NOM. CONDUIT E (X2) D 2 7/8 [71.85 mm] 2 7/8 [74.23 mm] B WATER SIDE ECON OMIZER F 1.0 [2.5cm] (X2) A (X2) 1 1/8 [2.9cm] (X2) 3 1/4 [8.3 cm](x2) G (DUCT OPENING) DETAIL A H (X2) AA BB (X2) TOP VIEW J HH WAT ER C ONNECTIONS (X2) K FF L (DUC T OPENING) DD N EE Q M (X2) A P 5/8 [1.6cm] (X2) R WATER C ONNECTIONS (X2) DRAIN CONN ECT ION Ø5/8 [1.6cm] NOMINAL COMPRESSOR ACCESS PANEL DRAIN CONNECTION Ø5/8 [1.6cm] NOMINAL FRONT VIEW LEFT SIDE VIEW T BLOWER ACCESS PANEL GG W (DUCT OPENING) S (DU CT OPENING) X U Y Z (DUCT OPENING) V (DUC T OPENING) RIGHT SIDE VIEW WITH END DISCHARGE REAR VIEW WITH STANDARD DISCHARGE Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 009H_062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 6 REV A 10/23/2012 66 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect DIMENSION REFERENCE UNIT SIZE A B C D E F G H J K L M N P Q R S T U V W X Y Z AA BB CC DD EE FF GG HH in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in cm in A IR F IL TER H x W ( i n) UNIT lb W EIG H T k g R EF R IG ER A N T C HA R G E (o z ) 009 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 013 33 .4 84 .8 30 .9 78 .5 19 .0 48 .3 14 .6 37 .1 17 .0 43 .2 26 .1 66 .3 17 .4 44 .2 0.0 0.0 2.9 7.4 1.9 4.8 13 .3 33 .8 0.8 2.1 9.8 24 .9 1.4 3.6 15 .0 38 .1 1/2 NPTF 6.8 17 .3 3.4 8.6 3.1 7.9 10 .3 26 .2 6.8 17 .3 3.4 8.6 1.6 4.1 10 .3 26 .2 9.7 24 .6 19 .4 49 .3 11 .9 30 .2 7.8 19 .8 12 .5 31 .8 0.9 2.3 20 .2 51 .3 1/2 NPTF 016 37 .3 94 .7 35 88 .9 20 .0 50 .8 14 .9 37 .9 17 .9 45 .5 26 .8 68 21 53 .3 0.4 1 3.0 7.6 1.9 4.8 14 .2 36 .1 0.8 2.1 12 .0 30 .5 1.8 4.6 17 .4 44 .2 1 /2 NPTF 8.4 21 .3 4.4 11 .2 5.4 13 .7 10 .4 26 .4 8.4 21 .3 4.4 11 .2 1.6 4.1 10 .4 26 .4 9.8 24 .9 23 .3 59 .2 12 .7 32 .3 9 22 .9 15 .1 38 .4 1.7 4.3 23 .8 60 .5 1 /2 NPTF 01 9 3 7.3 9 4.7 35 8 8.9 2 0.0 5 0.8 1 4.9 3 7.9 1 7.9 4 5.5 2 6.8 68 21 5 3.3 0 .4 1 3 .0 7 .6 1 .9 4 .8 1 4.2 3 6.1 0 .8 2 .1 1 2.0 3 0.5 1 .8 4 .6 1 7.4 4 4.2 1/2 NP TF 8 .4 2 1.3 4 .4 1 1.2 5 .4 1 3.7 1 0.4 2 6.4 8 .4 2 1.3 4 .4 1 1.2 1 .6 4 .1 1 0.4 2 6.4 9 .8 2 4.9 2 3.3 5 9.2 1 2.7 3 2.3 9 2 2.9 1 5.1 3 8.4 1 .7 4 .3 2 3.8 6 0.5 1/2 NP TF 024 4 4.4 112 .8 4 1.9 106 .4 2 2.0 5 5.9 1 6.6 4 2.2 2 0.0 5 0.8 2 8.8 7 3.2 2 8.5 7 2.4 0.4 1 3.3 8.4 2.1 5.3 1 6.2 4 1.2 0.8 2.1 1 1.9 3 0.2 1.5 3.8 1 9.0 4 8.3 1/2 NPTF 9.1 2 3.1 4.4 1 1.2 6.0 1 5.2 1 0.1 2 5.7 9.1 2 3.1 4.4 1 1.2 2.9 7.4 1 0.1 2 5.7 9.8 2 4.9 3 0.9 7 8.5 1 3.1 3 3.3 1 0.5 2 6.7 1 7.5 4 4.5 1.4 3.6 3 1.3 7 9.5 3/4 NPTF 030 44 .4 112 .8 41 .9 106 .4 22 .0 55 .9 16 .6 42 .2 20 .0 50 .8 28 .8 73 .2 28 .5 72 .4 0.4 1 3.6 9.1 2.1 5.3 16 .2 41 .2 0.8 2.1 13 .6 34 .5 1.6 4.1 19 .0 48 .3 3/4 NPTF 9.1 23 .1 4.4 11 .2 6.0 15 .2 10 .1 25 .7 9.1 23 .1 4.4 11 .2 2.9 7.4 10 .1 25 .7 9.8 24 .9 30 .9 78 .5 13 .1 33 .3 10 .5 26 .7 17 .5 44 .5 1.4 3.6 31 .3 79 .5 3/4 NPTF 036 44 .4 112.8 42 .0 106.6 8 22 .0 55 .9 16 .5 41 .9 20 .0 50 .8 29 .4 74 .7 28 .5 72 .4 .4 1 3.6 9.1 2.3 5.8 18 .2 46 .2 1.0 2.5 13 .6 34 .5 1.6 4.1 21 .0 53 .3 3/4 NPTF 10 .0 25 .4 3.6 9.1 7.9 20 .1 11 .4 28 .9 10 .0 25 .4 3.5 8.9 1.8 4.6 11 .4 28 .9 9.3 23 .6 30 .9 78 .5 13 .3 33 .8 10 .6 26 .9 19 .4 49 .3 1.5 3.8 31 .3 79 .5 3/4 NPTF 0 43 44.4 1 12.8 42.0 106.68 22.0 55.9 16.5 41.9 20.0 50.8 29.4 74.7 28.5 72.4 .4 1 3.6 9.1 2.3 5.8 18.2 46.2 1.0 2.5 15.5 39.4 1.6 4.1 21.0 53.3 3/4 NPTF 10.0 25.4 3.6 9.1 7.9 20.1 11.4 28.9 10.0 25.4 3.5 8.9 1.8 4.6 11.4 28.9 9.3 23.6 30.9 78.5 13.3 33.8 10.6 26.9 19.4 49.3 1.5 3.8 31.3 79.5 3/4 NPTF 15x 1 7 15x 17 1 6x 21 16x 21 18x 2 8 18x 28 2 0x 27. 5 20x 27 .5 174 79 18 4 83 255 116 255 116 285 129 32 0 14 5 390 177 390 177 26. 1 27. 0 30 .0 29.9 57. 0 53. 0 5 0.0 61.4 009H_ 062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 6 05 2 54.5 13 8.4 52.0 13 2.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1 .1 2 .8 4 .4 11.2 2 .6 6 .6 18.3 46.5 1 .0 2 .5 16.6 42.2 1 .4 3 .6 21.0 53.3 3/4 NPTF 12.6 32.1 4 .5 11.4 8 .1 20.6 11.4 28.9 12.6 32.0 4 .5 11.4 1 .5 3 .8 11.4 28.9 9 .7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1 .4 3 .6 41 10 4.1 3/4 NPTF 0 62 54.5 1 38.4 52.0 1 32.1 27.0 68.6 22.0 55.9 24.8 63.0 34.4 87.4 37.5 95.2 1.1 2.8 4.4 11.2 2.6 6.6 18.3 46.5 1.0 2.5 18.0 45.7 1.4 3.6 21.0 53.3 1 .0 NPTF 12.6 32.1 4.5 11.4 8.1 20.6 11.4 28.9 12.6 32.0 4.5 11.4 1.5 3.8 11.4 28.9 9.7 24.6 37.5 95.2 13.3 33.8 10.8 27.4 19.4 49.3 1.4 3.6 41 1 04.1 1 .0 NPTF 18 x 20( 1) , 18x 20 ( 1) , 20x 20( 1 ) 20x 2 0( 1) 515 5 30 234 2 40 71. 8 REV A 72 .0 10/23/2012 67 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H_ 062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 6 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV A 10/23/2012 68 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect Electrical Data Compressor Total Amps Min/Max Voltages MCA Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) 208-230/60/1 3.60 22.0 1.3 4.9 187/253 5.8 15 20 265/60/1 3.50 22.0 1.0 4.5 239/291 5.4 15 20 Unit Size Voltage 009 009 Unit Size Voltage 013 208-230/60/1 Unit Size Voltage 016 016 Unit Size Voltage 019 019 RLA Compressor LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 5.20 29.0 1.3 6.5 187/253 7.8 Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) 15 20 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 5.40 29.0 1.6 7.00 187/253 8.4 15 20 265/60/1 5.00 28.0 1.2 6.20 239/291 7.5 15 20 Compressor Maximum Overcurrent Minimum Protection (MOPD) Circuit Breaker RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 8.07 43.4 1.6 9.67 187/253 11.7 15 20 265/60/1 6.40 43.0 1.2 7.60 239/291 9.2 15 20 019 220/50/1 7.15 40.3 1.5 8.65 197/253 10.4 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 024 208-230/60/1 10.50 52.7 4.1 14.60 187/253 17.2 20 25 024 208-230/60/3 8.40 50.4 4.1 12.50 187/253 14.6 15 20 024 265/60/1 8.20 54.0 3.1 11.30 239/291 13.4 15 20 024 460/60/3 3.70 28.0 1.3 5.00 414/506 5.9 15 20 024 220/50/1 9.27 47.7 3.8 13.07 197/253 15.4 20 25 Unit Size Voltage 030 030 Compressor RLA LRA Compressor Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA 208-230/60/1 12.27 66.0 4.1 16.37 187/253 19.4 20 30 208-230/60/3 8.51 50.4 4.1 12.61 187/253 14.7 15 20 030 265/60/1 9.50 60.0 3.1 12.60 239/291 15.0 15 20 030 460/60/3 3.75 28.0 1.3 5.05 414/506 6.0 15 20 030 380/50/3 4.14 25.3 1.4 5.54 342/420 6.6 15 20 030 220/50/1 10.58 55.9 3.8 14.38 197/253 17.0 20 25 030 575/60/3 3.00 24.0 0.9 3.90 515/632 4.7 15 20 Unit Size Voltage Blower Motor (A) Total Amps Min/Max Voltages MCA 036 208-230/60/1 14.92 71.4 5.6 20.52 187/253 24.3 25 35 036 208-230/60/3 10.47 63.5 5.6 16.07 187/253 18.7 20 25 036 265/60/1 11.40 72.0 4.3 15.70 239/291 18.6 20 25 036 460/60/3 4.60 38.0 3.5 8.10 414/506 9.3 15 20 036 380/50/3 5.08 34.4 3.5 8.58 342/420 9.9 15 20 036 220/50/1 12.98 61.4 5.6 18.58 197/253 21.8 25 30 036 575/60/3 3.70 36.5 0.9 4.60 515/632 5.5 15 20 Compressor RLA LRA 009H_ 062H_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 6 Minimum Maximum Overcurrent Circuit Breaker Protection (MOPD) REV A 10/23/2012 69 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect Electrical Data - cont. Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 043 208-230/60/1 18.13 101.3 5.6 23.73 187/253 28.3 30 45 043 208-230/60/3 12.42 76.5 5.6 18.02 187/253 21.1 25 30 043 460/60/3 5.50 44.0 3.5 9.00 414/506 10.4 15 20 043 380/50/3 6.08 41.6 3.5 9.58 342/420 11.1 15 20 043 220/50/1 16.04 79.8 5.6 21.64 197/253 25.7 30 40 043 575/60/3 4.40 34.0 0.9 5.30 515/632 6.4 15 20 Unit Size Voltage Compressor RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 50 052 208-230/60/1 20.29 105.8 9.2 29.49 187/253 34.6 35 052 208-230/60/3 13.00 72.3 9.2 22.20 187/253 25.4 30 35 052 460/60/3 5.50 41.0 3.3 8.80 414/506 10.2 15 20 052 380/50/3 6.20 38.9 2.5 8.70 342/420 10.3 15 20 052 220/50/1 17.13 89.8 9.2 26.33 197/253 30.6 35 45 052 575/60/3 4.90 33.0 1.7 6.60 515/632 7.8 15 20 Unit Size Voltage RLA LRA Blower Motor (A) Total Amps Min/Max Voltages MCA Minimum Circuit Breaker Maximum Overcurrent Protection (MOPD) 062 208-230/60/1 24.88 121.2 9.2 34.08 187/253 40.3 45 60 062 208-230/60/3 16.56 95.7 9.2 25.76 187/253 29.9 30 45 062 460/60/3 7.15 52.0 3.3 10.45 414/506 12.2 15 20 062 380/50/3 7.74 46.6 2.5 10.24 342/420 12.2 15 20 062 220/50/1 22.58 117.3 9.2 31.78 197/253 37.4 40 60 062 575/60/3 5.70 38.9 1.7 7.40 515/632 8.8 15 20 Compressor 009_062H_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 6 REV A 10/23/2012 70 Submittal Data – Vertical Sizes 012 to 072, Right Hand VERTICAL U VINTAGE SINGLE CIRCUIT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V THRU 062V_U_RH RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Right hand water connections and electrical box location viewed looking into the return air duct connection. 012V THRU 062V_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 4 REV E 10/2/2012 71 Submittal Data – Vertical Sizes 012 to 072, Right Hand A E (DUCT OPENING) F LINE VOLTAGE CONDUIT CONNECTION G B D ELECTRICAL ACCESS PANEL H (DUCT OPEN ING) 1.4 [3.6cm] ACCESS PANEL C (DUCT OPENING) J (X2) Q (X2) CONTROL VOLT AGE ELECTRICAL BOX (N/A FOR 052, 062) WATER OUT WATER IN ACCESS PANEL P (DUCT OPENING) 1.0 [2.5cm] M WAT ER CONNECT IONS (X2) K 3.6 [9.1cm] (X2) S T R 7.9 [20.1cm] 9.0 [22.9cm] U 16.6 [42.2cm] DRAIN C ONNECTION 3/4 [1.9cm] NOMINAL N L (X2) 3.9 [9.9cm] Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V THRU 062V_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 4 REV E 10/2/2012 72 Submittal Data – Vertical Sizes 012 to 072, Right Hand DIMENSION REFERENCE UNIT SIZE 012 024 030 036 043 052 062 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 B cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 19.4 22.1 22.1 22.1 22.1 25.0 25.0 D cm 49.3 56.1 56.1 56.1 56.1 63.5 63.5 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.0 1.0 J cm 3.6 3.8 3.8 3.8 3.8 2.5 2.5 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 1.0 NPTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.4 22.4 26.3 26.3 34.4 34.4 P cm 45.7 56.9 56.9 66.8 66.8 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N/A N/A U cm 5.1 8.4 8.4 8.4 8.4 N/A N/A A IR F IL TER H x W ( in ) U N IT lb W EIG HT k g RE F RIG ER A N T CH A R G E ( oz ) 1 8 X 20 17 5 79 20 X 25 235 107 20 X 25 250 113 14 X 20 ( 2) 250 113 14 X 20 ( 2) 300 136 1 8 X 25 ( 2) 3 40 1 54 18 X 25 ( 2) 360 163 29.0 54.0 54.0 46.0 56.0 79.0 87 .0 012V THRU 062V_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 4 REV E 10/2/2012 73 Submittal Data – Vertical Sizes 012 to 072, Right Hand E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Unit Size V olt age Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 043 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA 012V THRU 062V_U_RH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 4 20 REV E 10/2/2012 74 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect VERTICAL U VINTAGE SINGLE CIRCUIT WITH NON-FUSED DISCONNECT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V_062V_U_RH_NFD RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Right hand water connections and electrical box location viewed looking into the return air duct connection. 012V_062V_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV C 10/23/2012 75 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect 25A Dim B Dim C 63A Size Dim A Dim D Dim E Size Dim A Dim B 012 2.52 [64] 5.75 [146] 22.55 [573] 28.92 [735] 33.55 [852] 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] Dim C Dim D Dim E 024-030 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 036-043 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 2.52 [64] 5.75 [146] 34.92 [887] 41.30 [1049] 46.68 [1186] 45A Size Dim A 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] Dim B Dim C Dim D Dim E 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] Dimensions are inches [millimeters] A C D E B Right hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 012V_062V_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV C 10/23/2012 76 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect A E (DU CT OPENING) F G B D ELECTRICAL ACCESS PANEL H (DUCT OPENING) ACCESS PANEL C (DU CT OPENING) J (X2) CONTROL VOLTAGE ELECTRICAL BOX (N /A FOR 052, 062) WATER OUT WATER IN Q (X2) 7.9 [20.1cm] T S R 9.0 [22.9cm] ACCESS PANEL P (DUC T OPENING) 1.0 [2.5cm] M WAT ER CONNECTIONS (X2) K 3.6 [9.1cm] (X2) U 16.6 [42.2cm] CONDENSATE DRAIN CONNECTION Ø3/4 [1.9cm] NOM. N L (X2) 3.9 [9.9cm] Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V_062V_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 REV C 10/23/2012 77 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect DIMENSION REFERENCE UNIT SIZE 012 024 030 036 043 052 062 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 B cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 19.4 22.1 22.1 22.1 22.1 25.0 25.0 D cm 49.3 56.1 56.1 56.1 56.1 63.5 63.5 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.0 1.0 J cm 3.6 3.8 3.8 3.8 3.8 2.5 2.5 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 1.0 NPTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.4 22.4 26.3 26.3 34.4 34.4 P cm 45.7 56.9 56.9 66.8 66.8 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N/A N/A U cm 5.1 8.4 8.4 8.4 8.4 N/A N/A A IR F IL TER H x W ( in ) U N IT lb W EIG HT k g RE F RIG ER A N T CH A R G E ( oz ) 1 8 X 20 17 5 79 20 X 25 235 107 20 X 25 250 113 14 X 20 ( 2) 250 113 14 X 20 ( 2) 300 136 1 8 X 25 ( 2) 3 40 1 54 18 X 25 ( 2) 360 163 29.0 54.0 54.0 46.0 56.0 79.0 87 .0 012V_062V_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 REV C 10/23/2012 78 Submittal Data – Vertical Sizes 012 to 072, Right Hand with Non-Fused Disconnect E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Siz e V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Siz e V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Unit Siz e V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Unit Siz e V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Unit Siz e V olt age Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 043 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Siz e V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Siz e V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA 012V_062V_U_RH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 20 REV C 10/23/2012 79 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil VERTICAL U VINTAGE SINGLE CIRCUIT W/ WATER SIDE ECONOMIZER W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V THRU 062V_U_RH_WSE RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. CR OSS-OVER PIPING WAT ER OUT T O CONDENSER WATER OUT TO BUILDING CONDENSER IN WATER IN FR OM BUILDING Right hand water connections and electrical box location viewed looking into the return air duct connection. 012V THRU 062V_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 4 REV E 10/2/2012 80 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil A E (DU CT OPEN IN G) LINE VOLTAGE CONDUIT CONNECTION ELEC TRICAL ACCESS PANEL D G (DUCT OPENING) H F B ACCESS PANEL 3.6 [91.2 mm] (X2) 1.4 [3.6cm] J (X2) AA (X2) P (DUCT OPENING) Q (X2) CONTR OL VOLTAGE ELECTRICAL BOX (N/A FOR 052, 062) Y R X V DRAIN CONNECT ION Ø5/8 (1.6cm) NOMINAL (X2) DRAIN C ONNECTION Ø3/4 [1.9cm] NOMINAL (X2) 16.6 [42.2cm] ACCESS PANEL M WATER CONNECTION S (X2) 1.0 [2.5cm] T 7.9 [20.1cm] 9.0 [22.9cm] K Z WATER CONNECTION S (X2) U W (X2) 1.0 [25.4 mm] N S C (DUC T OPENING) L (X2) 3.9 [9.9cm] Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V THRU 062V_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 4 REV E 10/2/2012 81 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil DIMENSION REFERENCE 012 024 030 036 043 052 062 UNIT SIZE in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 31.5 31.5 31.5 31.5 34.5 34.5 B cm 46.0 80.0 80.0 80.0 80.0 87.6 87.6 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 22.6 26.4 26.4 26.4 26.4 28.1 28.1 D cm 57.4 67.1 67.1 67.1 67.1 71.4 71.4 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.1 1.1 J cm 3.6 3.8 3.8 3.8 3.8 2.8 2.8 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 N PTF 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.8 22.8 26.4 26.4 34.4 34.4 P cm 45.7 57.9 57.9 67.1 67.1 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N /A N/A U cm 5.1 8.4 8.4 8.4 8.4 N /A N/A in 12.8 12.6 12.6 10.1 10.1 8.4 8.4 V cm 32.5 32.0 32.0 25.7 25.7 21.3 21.3 in 22.6 25.5 25.5 25.3 25.3 28.1 28.1 W cm 57.4 64.8 64.8 64.3 64.3 71.4 71.4 in 22.9 26.6 26.6 25.5 25.5 30.0 30.0 X cm 58.2 67.6 67.6 64.8 64.8 76.2 76.2 in 18.6 21.6 21.6 20.5 20.5 22.0 22.0 Y cm 47.2 54.9 54.9 52.1 52.1 55.9 55.9 in 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF Z cm in 1.8 2.0 2.0 0.9 0.8 0.9 1.0 AA cm 4.6 5.1 5.1 2.3 2.0 2.3 2.5 A IR FI LT ER H x W (in) lb UNIT WEI GHT kg REF RIGERA NT CHA RGE ( oz) 320 145 14 X 20 ( 2) 370 168 14 X 20 (2) 370 168 18 X 25 (2) 450 204 18 X 25 (2) 450 204 54.0 46.0 56. 0 79. 0 87.0 18 X 20 20 X 25 20 X 25 225 102 320 145 29. 0 54. 0 012V THRU 062V_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 4 REV E 10/2/2012 82 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 Unit Size V olt age Com pre ssor RLA L RA 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 043 Unit Size 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA 012V THRU 062V_U_RH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 4 20 REV E 10/2/2012 83 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect W A TE R S O UR C E H E A T P U M P VERTICAL U VINTAGE W/ WATER SIDE ECONOMIZER AND NON-FUSED DISCONNECT SUBMITTAL PACKAGE 012V_062V_U_RH_WSE_NFD RIGHT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. CROSS-OVER PIPIN G WAT ER OUT T O CONDENSER WATER OUT TO BUILDING CONDENSER IN WATER IN FR OM BUILDING Right hand water connections and electrical box location viewed looking into the return air duct connection. 012V_062V_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV A 10/23/2012 84 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect 25A Dim B Dim C 63A Size Dim A Dim D Dim E Size Dim A Dim B 012 2.52 [64] 5.75 [146] 22.55 [573] 28.92 [735] 33.55 [852] 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] Dim C Dim D Dim E 024-030 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 036-043 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 2.52 [64] 5.75 [146] 34.92 [887] 41.30 [1049] 46.68 [1186] Size Dim A 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 45A Dim B Dim C Dim D Dim E Dimensions are inches [millimeters] A C D E B Right hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 012V_062V_U_RH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV A 10/23/2012 85 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect A E ( DUCT OPENING) ELECTRICAL ACCESS PANEL D G (DUC T OPENING) H F B ACCESS PANEL 3.6 [91.2 mm] (X2) 1.4 [3.6cm] C ( DUCT OPENING) J (X2) AA (X2) Q (X2) M WATER C ONNECTIONS (X2) P (DUCT OPENING) 7.9 [20.1cm] 1.0 [2.5cm] V T U 16.6 [42.2cm] D RAIN CONNECTION Ø5/8 (1.6cm) N OMINAL ( X2) DRAIN CONNECT ION Ø3/4 [1.9cm] NOMINAL CONT ROL (X2) VOLTAGE 3.9 [9.9cm] ELECT RICAL BOX (N/A FOR 052, 062) N S Y R X 9.0 [22.9cm] K Z WAT ER CONN ECT IONS ( X2) ACCESS PANEL W ( X2) 1.0 [25.4 mm] L (X2) Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V_062V_U_RH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 REV A 10/23/2012 86 Submittal Data – Vertical Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect DIMENSION REFERENCE 012 024 030 036 043 052 062 UNIT SIZE in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 31.5 31.5 31.5 31.5 34.5 34.5 B cm 46.0 80.0 80.0 80.0 80.0 87.6 87.6 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 22.6 26.4 26.4 26.4 26.4 28.1 28.1 D cm 57.4 67.1 67.1 67.1 67.1 71.4 71.4 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.1 1.1 J cm 3.6 3.8 3.8 3.8 3.8 2.8 2.8 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 N PTF 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.8 22.8 26.4 26.4 34.4 34.4 P cm 45.7 57.9 57.9 67.1 67.1 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N /A N/A U cm 5.1 8.4 8.4 8.4 8.4 N /A N/A in 12.8 12.6 12.6 10.1 10.1 8.4 8.4 V cm 32.5 32.0 32.0 25.7 25.7 21.3 21.3 in 22.6 25.5 25.5 25.3 25.3 28.1 28.1 W cm 57.4 64.8 64.8 64.3 64.3 71.4 71.4 in 22.9 26.6 26.6 25.5 25.5 30.0 30.0 X cm 58.2 67.6 67.6 64.8 64.8 76.2 76.2 in 18.6 21.6 21.6 20.5 20.5 22.0 22.0 Y cm 47.2 54.9 54.9 52.1 52.1 55.9 55.9 in 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF Z cm in 1.8 2.0 2.0 0.9 0.8 0.9 1.0 AA cm 4.6 5.1 5.1 2.3 2.0 2.3 2.5 A IR FILTER H x W (in) lb UNIT WEIGHT kg REF RIGERA NT CHA RGE ( oz) 320 145 14 X 20 ( 2) 370 168 14 X 20 (2) 370 168 18 X 25 (2) 450 204 18 X 25 (2) 450 204 54.0 46.0 56.0 79.0 87.0 18 X 20 20 X 25 20 X 25 225 102 320 145 29.0 54.0 012V_062V_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 REV A 10/23/2012 87 Submittal Data – Horizontal Sizes 009 to 062, Right Hand with Waterside Economizer Coil and Non-Fused Disconnect E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 Unit Size V olt age Com pre ssor RLA L RA 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 043 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA Com pre ssor RLA L RA 012V_062V_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 20 REV A 10/23/2012 88 Submittal Data – Vertical Sizes 012 to 072, Left Hand VERTICAL U VINTAGE SINGLE CIRCUIT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V THRU 062V_U_LH LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Left hand water connections and electrical box location viewed looking in to the return air duct connection. 012V THRU 062V_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 4 REV E 10/2/2012 89 Submittal Data – Vertical Sizes 012 to 072, Left Hand A E (DUCT OPENING) LIN E VOLT AGE CONDUIT CONNECTION F G B D ELECTRICAL ACCESS PANEL H (DUCT OPENING) 1.4 [3.6cm] J (X2) ACCESS PANEL M WATER CON NECT IONS (X2) 1.0 [2.5cm] ACCESS PAN EL 3.6 [9.1cm] (X2) C (DUCT OPENING) WAT ER OUT C ONTR OL VOLTAGE ELECTRICAL BOX (N/A FOR 052,062) WATER IN K P (DUCT OPEN ING) Q (X2) 7.9 [20.1cm] T S R 9.0 [22.9cm] L (X2) 16.6 [42.2cm] N 3.9 [9.9cm] U DRAIN CONNECT ION Ø3/4 [1.9 cm] NOMIN AL Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V THRU 062V_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 4 REV E 10/2/2012 90 Submittal Data – Vertical Sizes 012 to 072, Left Hand DIMENSION REFERENCE UNIT SIZE 012 024 030 036 043 052 062 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 B cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 19.4 22.1 22.1 22.1 22.1 25.0 25.0 D cm 49.3 56.1 56.1 56.1 56.1 63.5 63.5 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.0 1.0 J cm 3.6 3.8 3.8 3.8 3.8 2.5 2.5 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 1.0 NPTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.4 22.4 26.3 26.3 34.4 34.4 P cm 45.7 56.9 56.9 66.8 66.8 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N/A N/A U cm 5.1 8.4 8.4 8.4 8.4 N/A N/A A I R F I LT E R H x W (i n ) U N IT lb W EIG HT k g R EF R IGE R A N T C H A R GE ( o z) 250 113 14 X 20 ( 2) 250 113 14 X 20 ( 2) 3 00 1 36 18 X 25 ( 2) 340 154 18 X 25 ( 2) 360 163 54 .0 4 6.0 56.0 79.0 8 7.0 18 X 2 0 20 X 25 2 0 X 25 175 79 235 107 29.0 54 .0 012V THRU 062V_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 4 REV E 10/2/2012 91 Submittal Data – Vertical Sizes 012 to 072, Left Hand E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Unit Size V olt age Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 043 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA 012V THRU 062V_U_LH Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 4 20 REV E 10/2/2012 92 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect VERTICAL U VINTAGE SINGLE CIRCUIT WITH NON-FUSED DISCONNECT W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V_062V_U_LH_NFD LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. Left hand water connections and electrical box location viewed looking in to the return air duct connection. 012V_062V_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV C 10/23/2012 93 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect 25A Dim B Dim C 63A Size Dim A Dim D Dim E Size Dim A Dim B 012 2.52 [64] 5.75 [146] 22.55 [573] 28.92 [735] 33.55 [852] 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] Dim C Dim D Dim E 024-030 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 036-043 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 2.52 [64] 5.75 [146] 34.92 [887] 41.30 [1049] 46.68 [1186] Size Dim A 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 45A Dim B Dim C Dim D Dim E Dimensions are inches [millimeters] A C D E B Left hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 012V_062V_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV C 10/23/2012 94 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect A E (DUCT OPENING) F G H (DUC T OPENING) D B ELEC TRICAL ACC ESS PANEL 1.4 [3.6cm] J (X2) ACCESS PANEL M WATER CONNECTIONS (X2) ACCESS PANEL 3.6 [9.1cm] (X2) C (DUCT OPENING) WATER OUT WAT ER IN K P (DUCT OPENING) 1.0 [2.5cm] CONT ROL VOLTAGE ELECTRIC AL BOX (N/A FOR 052,062) Q (X2) 7.9 [20.1cm] T R S 9.0 [22.9cm] L (X2) 16.6 [42.2cm] N 3.9 [9.9cm] U DR AIN CONNECTION Ø3/4 [1.9 cm] N OMINAL Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V_062V_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 REV C 10/23/2012 95 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect DIMENSION REFERENCE UNIT SIZE 012 024 030 036 043 052 062 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 B cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 19.4 22.1 22.1 22.1 22.1 25.0 25.0 D cm 49.3 56.1 56.1 56.1 56.1 63.5 63.5 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.0 1.0 J cm 3.6 3.8 3.8 3.8 3.8 2.5 2.5 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 NPTF 1/2 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 3/4 NPTF 1.0 NPTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.4 22.4 26.3 26.3 34.4 34.4 P cm 45.7 56.9 56.9 66.8 66.8 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N/A N/A U cm 5.1 8.4 8.4 8.4 8.4 N/A N/A A I R F I LT E R H x W (i n ) U N IT lb W EIG HT k g R EF R IGE R A N T C H A R GE ( o z) 250 113 14 X 20 ( 2) 250 113 14 X 20 ( 2) 3 00 1 36 18 X 25 ( 2) 340 154 18 X 25 ( 2) 360 163 54 .0 4 6.0 56.0 79.0 8 7.0 18 X 2 0 20 X 25 2 0 X 25 175 79 235 107 29.0 54 .0 012V_062V_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 REV C 10/23/2012 96 Submittal Data – Vertical Sizes 012 to 072, Left Hand with Non-Fused Disconnect E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Siz e V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Siz e V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Unit Siz e V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Unit Siz e V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Unit Siz e V olt age Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 043 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Siz e V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Siz e V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA Com pre ssor RLA L RA 012V_062V_U_LH_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 20 REV C 10/23/2012 97 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil VERTICAL U VINTAGE SINGLE CIRCUIT W/ WATER SIDE ECONOMIZER W A TE R S O UR C E H E A T P U M P SUBMITTAL PACKAGE 012V THRU 062V_U_LH_WSE LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. CROSS-OVER PI PING WATER OUT TO CONDENSER IN WATER OUT TO BUILDING CONDENSER IN WATER IN FROM BUILDI NG Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 012V THRU 062V_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 4 REV E 10/2/2012 98 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil A F D G ELECTRICAL ACC ESS PANEL E (D UCT OPENING) H (DUCT OPENING) LINE VOLTAGE CONDUIT CONNECTION B ACCESS PANEL 3.6 [9.1cm] (X2) 1.4 [3.6cm] J (X2) C (DUCT OPEN IN G) W (X2) AA (X2) 1.0 [2.5cm] Q (X2) DRAIN CONNECT ION Ø5/8 [1.6cm] NOMINAL (X2) V Y S R X 1.0 [2.5cm] K Z WAT ER CONNECTIONS (X2) 9.0 [22.9cm] P (DUCT OPENING) M WATER CONNECTION S (X2) 7.9 [20.1cm] ACCESS PANEL DRAIN CONNECTION Ø3/4 [1.9cm] NOMINAL (X2) L (X2) N T 3.9 [9.9cm] CONTROL VOLTAGE ELECTRICAL BOX (N/A F OR 052, 062) 16.6 [42.2cm] U Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V THRU 062V_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 4 REV E 10/2/2012 99 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil DIMENSION REFERENCE 012 024 030 036 043 052 062 UNIT SIZE in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 31.5 31.5 31.5 31.5 34.5 34.5 B cm 46.0 80.0 80.0 80.0 80.0 87.6 87.6 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 22.6 26.4 26.4 26.4 26.4 28.1 28.1 D cm 57.4 67.1 67.1 67.1 67.1 71.4 71.4 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.1 1.1 J cm 3.6 3.8 3.8 3.8 3.8 2.8 2.8 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 N PTF 1/2 NPTF 3/4 N PTF 3/4 NPTF 3/4 NP TF 3/4 N PTF 1.0 N PTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.8 22.8 26.4 26.4 34.4 34.4 P cm 45.7 57.9 57.9 67.1 67.1 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N /A N/A U cm 5.1 8.4 8.4 8.4 8.4 N /A N/A in 12.8 12.6 12.6 10.1 10.1 8.4 8.4 V cm 32.5 32.0 32.0 25.7 25.7 21.3 21.3 in 22.6 25.5 25.5 25.3 25.3 28.1 28.1 W cm 57.4 64.8 64.8 64.3 64.3 71.4 71.4 in 22.9 26.6 26.6 25.5 25.5 30.0 30.0 X cm 58.2 67.6 67.6 64.8 64.8 76.2 76.2 in 18.6 21.6 21.6 20.5 20.5 22.0 22.0 Y cm 47.2 54.9 54.9 52.1 52.1 55.9 55.9 in 1/2 N PTF 3/4 NPTF 3/4 N PTF 3/4 NPTF 3/4 NP TF 3/4 N PTF 1.0 N PTF Z cm in 1.8 2.0 2.0 0.9 0.8 0.9 1.0 AA cm 4.6 5.1 5.1 2.3 2.0 2.3 2.5 AIR FILTER H x W (in ) lb UNIT WEIGHT kg REFRIGERA NT CHA RGE (oz) 320 145 14 X 20 (2) 370 168 14 X 20 (2) 370 168 18 X 25 (2) 450 204 18 X 25 (2) 450 204 54.0 46.0 56.0 79.0 87.0 18 X 20 20 X 25 20 X 25 225 102 320 145 29.0 54.0 012V THRU 062V_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 4 REV E 10/2/2012 100 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 Unit Size V olt age Com pre ssor RLA L RA 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 043 Unit Size 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA 012V THRU 062V_U_LH_WSE Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 4 20 REV E 10/2/2012 101 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect W A TE R S O UR C E H E A T P U M P VERTICAL U VINTAGE W/ WATER SIDE ECONOMIZER AND NON-FUSED DISCONNECT SUBMITTAL PACKAGE 012V_062V_U_LH_WSE_NFD LEFT HAND Mammoth In c. certifi es tha t it w ill furnish eq uip me nt in acco rd ance wi th this drawi ng and spe ci fi cati ons, a nd subje ct to i ts publ ished wa rranty. Purchase r's ap proval of thi s d ra win g si gnifies that the eq uipme nt is acce pta ble un der the p ro vision s of th e j ob specifica tio ns. Any chang e ma de hereo n b y a ny p erson whome ve r i s subj ect to acceptance by Mammoth Inc. 1 3200 Pi oneer Trail, Ste 150 , Eden Prai rie, MN 553 47. General Specifications CABINET - Outer casing of G-60 galvanize d steel. FAN - Centrifugal type with forward curved wheel. REFRIGERANT CIRCUIT - Hermetically sea led 410A circuitry FAN MOTOR - Multiple speed PSC type with sleeve bearing, with reversing valve (HP only), TX metering device, in tegral rubber mounts and inherent overload protection. an d high/low side access valve. E LECTRICAL - 24-volt microprocessor control system with COMPRESSOR - Her metic type with PSC or three phase fan relay, compressor contactor, reversing valve coil (HP only) . motor, overload protectio n and mounted on neoprene isolators. CONTROL - Standard CAV operation by field mounted, AIR COIL - Seamless copper tubes and aluminum fins. wall type thermostat. HEAT EXCHANGER - Coaxial water to refrig erant with steel ou ter tube and convolu ted copper inner tube. FILTER - 1-inch thick disposable INSULATION - Thermally and acoustically optimized 3/4 inch thick, 1 1/2 lb. density faced. CROSS-OVER PIPING WATER OUT TO CONDENSER IN W ATER OUT TO BUILDING CONDENSER IN W ATER IN FROM BUILDING Left hand water connections a nd electrical box locatio n viewed looking into the return air duct connection. 012V_062V_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 1 OF 5 REV A 10/23/2012 102 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect 25A Dim B Dim C 63A Size Dim A Dim D Dim E Size Dim A Dim B 012 2.52 [64] 5.75 [146] 22.55 [573] 28.92 [735] 33.55 [852] 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] Dim C Dim D Dim E 024-030 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 036-043 2.52 [64] 5.75 [146] 28.05 [712] 34.42 [874] 39.05 [992] 052-062 2.52 [64] 5.75 [146] 34.92 [887] 41.30 [1049] 46.68 [1186] Size Dim A 036-043 3.84 [98] 5.75 [146] 26.69 [678] 34.29 [871] 39.05 [992] 052-062 3.84 [98] 5.75 [146] 34.31 [871] 41.91 [1065] 46.68 [1186] 45A Dim B Dim C Dim D Dim E Dimensions are inches [millimeters] A C D E B Left hand non-fused disconnect and electrical box when viewed looking into the return air duct connection. Spe cifica ti ons sub ject to c han ge wi th out no tic e. 012V_062V_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 2 OF 5 REV A 10/23/2012 103 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect A F D G ELECT RICAL ACCESS PANEL H (DUCT OPENING) E (DUCT OPENING) B ACCESS PANEL 3.6 [9.1cm] (X2) 1.4 [3.6cm] J (X2) C (D UCT OPENING) W (X2) ACCESS PANEL AA (X2) 1.0 [2.5cm] DRAIN CONNECTION Ø5/8 [1.6cm] NOMIN AL (X2) V Y S R X 1.0 [2.5cm] K Q (X2) 9.0 [22.9cm] P (DU CT OPENING) M WATER CONNECT IONS (X2) 7.9 [20.1cm] Z WAT ER CONNECTIONS (X2) DR AIN CONNECTION Ø3/4 [1.9cm] NOMINAL (X2) L (X2) N T 3.9 [9.9cm] CONTROL VOLTAGE ELECTRICAL BOX (N /A FOR 052, 062) 16.6 [42.2cm] U Sp eci fi cation s su bje ct to cha nge w ithou t no tice. 012V_062V_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 3 OF 5 REV A 10/23/2012 104 Submittal Data – Vertical Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect DIMENSION REFERENCE 012 024 030 036 043 052 062 UNIT SIZE in 20.7 23.5 23.5 23.5 23.5 26.5 26.5 A cm 52.6 59.7 59.7 59.7 59.7 67.3 67.3 in 18.1 31.5 31.5 31.5 31.5 34.5 34.5 B cm 46.0 80.0 80.0 80.0 80.0 87.6 87.6 in 18.1 20.5 20.5 20.5 20.5 24.5 24.5 C cm 46.0 52.1 52.1 52.1 52.1 62.2 62.2 in 22.6 26.4 26.4 26.4 26.4 28.1 28.1 D cm 57.4 67.1 67.1 67.1 67.1 71.4 71.4 in 10.3 9.1 10.1 10.1 10.1 13.8 12.8 E cm 26.2 23.1 25.7 25.7 25.7 35.1 32.5 in 5.0 4.6 3.9 3.9 3.9 4.5 4.5 F cm 12.7 11.7 9.9 9.9 9.9 11.4 11.4 in 4.0 0.8 0.6 0.6 0.6 0.8 0.8 G cm 10.2 2.0 1.5 1.5 1.5 2.0 2.0 in 8.4 9.4 11.5 11.5 11.5 11.5 11.5 H cm 21.3 23.9 29.2 29.2 29.2 29.2 29.2 in 1.4 1.5 1.5 1.5 1.5 1.1 1.1 J cm 3.6 3.8 3.8 3.8 3.8 2.8 2.8 in 31.0 36.5 36.5 36.5 36.5 44.1 44.1 K cm 78.7 92.7 92.7 92.7 92.7 112.0 112.0 in 1.1 1.4 1.4 1.4 1.4 1.5 1.5 L cm 2.8 3.6 3.6 3.6 3.6 3.8 3.8 in 1/2 N PTF 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF M cm in 1.4 1.4 1.4 1.4 1.4 1.5 1.5 N cm 3.6 3.6 3.6 3.6 3.6 3.8 3.8 in 18.0 22.8 22.8 26.4 26.4 34.4 34.4 P cm 45.7 57.9 57.9 67.1 67.1 87.4 87.4 in 0.9 0.8 0.8 0.8 0.8 0.6 0.9 Q cm 2.3 2.0 2.0 2.0 2.0 1.5 2.3 in 17.3 21.8 21.8 21.8 21.8 27.3 27.3 R cm 43.9 55.4 55.4 55.4 55.4 69.3 69.3 in 15.0 19.5 19.5 19.5 19.5 24.9 24.9 S cm 38.1 49.5 49.5 49.5 49.5 63.2 63.2 in 3.6 4.4 4.4 5.1 5.1 5.0 5.0 T cm 9.1 11.2 11.2 13.0 13.0 12.7 12.7 in 2.0 3.3 3.3 3.3 3.3 N /A N/A U cm 5.1 8.4 8.4 8.4 8.4 N /A N/A in 12.8 12.6 12.6 10.1 10.1 8.4 8.4 V cm 32.5 32.0 32.0 25.7 25.7 21.3 21.3 in 22.6 25.5 25.5 25.3 25.3 28.1 28.1 W cm 57.4 64.8 64.8 64.3 64.3 71.4 71.4 in 22.9 26.6 26.6 25.5 25.5 30.0 30.0 X cm 58.2 67.6 67.6 64.8 64.8 76.2 76.2 in 18.6 21.6 21.6 20.5 20.5 22.0 22.0 Y cm 47.2 54.9 54.9 52.1 52.1 55.9 55.9 in 1/2 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 3/4 N PTF 1.0 N PTF Z cm in 1.8 2.0 2.0 0.9 0.8 0.9 1.0 AA cm 4.6 5.1 5.1 2.3 2.0 2.3 2.5 A IR FILTER H x W (in) lb UNIT WEIGHT kg REF RIGERA NT CHA RGE ( oz) 320 145 14 X 20 ( 2) 370 168 14 X 20 (2) 370 168 18 X 25 (2) 450 204 18 X 25 (2) 450 204 54.0 46.0 56.0 79.0 87.0 18 X 20 20 X 25 20 X 25 225 102 320 145 29.0 54.0 012V_062V_U_RH_WSE_ NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 4 OF 5 REV A 10/23/2012 105 Submittal Data – Horizontal Sizes 009 to 062, Left Hand with Waterside Economizer Coil and Non-Fused Disconnect E lect rical Da ta Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 2 9 .0 Bl ow e r M otor (A) 1 .6 6 .8 187/253 8 .1 15 20 Com pre ssor RLA L RA Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 5 2 .7 5 0 .4 4 .1 4 .1 1 4 .6 0 1 2 .5 0 187/253 187/253 17.2 14.6 20 15 25 20 5 4 .0 2 8 .0 4 7 .7 3 .1 1 .3 3 .8 1 1 .3 0 5 .0 0 1 3 .0 7 239/291 414/506 197/253 13.4 5 .9 15.4 15 15 20 20 20 25 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 6 6 .0 5 0 .4 Bl ow e r M otor (A) 4 .1 4 .1 1 6 .3 7 1 2 .6 1 187/253 187/253 19.4 14.7 20 15 30 20 9 .5 0 3 .7 5 6 0 .0 2 8 .0 3 .1 1 .3 1 2 .6 0 5 .0 5 239/291 414/506 15.0 6 .0 15 15 20 20 4 .1 4 1 0 .5 8 3 .0 0 2 5 .3 5 5 .9 2 4 .0 1 .4 3 .8 0 .9 5 .5 4 1 4 .3 8 3 .9 0 342/420 197/253 515/632 6 .6 17.0 4 .7 15 20 15 20 25 20 Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 7 1 .4 6 3 .5 Bl ow e r M otor (A) 5 .6 5 .6 2 0 .5 2 1 6 .0 7 187/253 187/253 24.3 18.7 25 20 35 25 1 1 .4 0 4 .6 0 7 2 .0 3 8 .0 4 .3 3 .5 1 5 .7 0 8 .1 0 239/291 414/506 18.6 9 .3 20 15 25 20 5 .0 8 1 2 .9 8 3 .7 0 3 4 .4 6 1 .4 3 6 .5 3 .5 5 .6 0 .9 8 .5 8 1 8 .5 8 4 .6 0 342/420 197/253 515/632 9 .9 21.8 5 .5 15 25 15 20 30 20 Bl ow e r M otor (A) Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 1 0 1 .3 7 6 .5 5 .6 5 .6 2 3 .7 3 1 8 .0 2 187/253 187/253 28.3 21.1 30 25 45 30 5 .5 0 6 .0 8 1 6 .0 4 4 4 .0 4 1 .6 7 9 .8 3 .5 3 .5 5 .6 9 .0 0 9 .5 8 2 1 .6 4 414/506 342/420 197/253 10.4 11.1 25.7 15 15 30 20 20 40 5 7 5 /6 0 / 3 4 .4 0 3 4 .0 0 .9 5 .3 0 515/632 6 .4 15 20 Unit Size V olt age Com pre ssor RLA L RA Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 052 2 0 8 -2 3 0 / 6 0 /1 2 0 .2 9 1 0 5 .8 Bl ow e r M otor (A) 9 .2 2 9 .4 9 187/253 34.6 35 50 052 052 2 0 8 -2 3 0 / 6 0 /3 4 6 0 /6 0 / 3 1 3 .0 0 5 .5 0 7 2 .3 4 1 .0 9 .2 3 .3 2 2 .2 0 8 .8 0 187/253 414/506 25.4 10.2 30 15 35 20 052 052 052 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 6 .2 0 1 7 .1 3 4 .9 0 3 8 .9 8 9 .8 3 3 .0 2 .5 9 .2 1 .7 8 .7 0 2 6 .3 3 6 .6 0 342/420 197/253 515/632 10.3 30.6 7 .8 15 35 15 20 45 20 Unit Size V olt age Tot al Am ps M in/M ax V olt age s M CA M inim um Cir cuit Br e ake r M axim um Ov e rcurr e nt Prot e ct ion (M OPD ) 062 062 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 2 4 .8 8 1 6 .5 6 1 2 1 .2 9 5 .7 Bl ow e r M otor (A) 9 .2 9 .2 3 4 .0 8 2 5 .7 6 187/253 187/253 40.3 29.9 45 30 60 45 062 062 062 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 7 .1 5 7 .7 4 2 2 .5 8 5 2 .0 4 6 .6 1 1 7 .3 3 .3 2 .5 9 .2 1 0 .4 5 1 0 .2 4 3 1 .7 8 414/506 342/420 197/253 12.2 12.2 37.4 15 15 40 20 20 60 062 5 7 5 /6 0 / 3 5 .7 0 3 8 .9 1 .7 7 .4 0 515/632 8 .8 15 Com pre ssor RLA L RA Unit Size V olt age 012 2 0 8 -2 3 0 / 6 0 /1 Unit Size V olt age 024 024 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 0 .5 0 8 .4 0 024 024 024 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 2 2 0 /5 0 / 1 8 .2 0 3 .7 0 9 .2 7 Unit Size V olt age Com pre ssor RLA L RA 030 030 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 2 .2 7 8 .5 1 030 030 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 030 030 030 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 036 036 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 4 .9 2 1 0 .4 7 036 036 2 6 5 /6 0 / 1 4 6 0 /6 0 / 3 036 036 036 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 5 7 5 /6 0 / 3 Unit Size V olt age 043 043 2 0 8 -2 3 0 / 6 0 /1 2 0 8 -2 3 0 / 6 0 /3 1 8 .1 3 1 2 .4 2 043 043 043 4 6 0 /6 0 / 3 3 8 0 /5 0 / 3 2 2 0 /5 0 / 1 043 5 .2 0 Com pre ssor RLA L RA Com pre ssor RLA L RA Com pre ssor RLA L RA 012V_062V_U_LH_WSE_NFD Catalog MAMM-WHSP-PC-1UE (January 2013) SHEET 5 OF 5 20 REV A 10/23/2012 106 Catalog MAMM-WHSP-PC-1UE (January 2013) 107 info@mammoth-inc.com www.mammoth-inc.com Mammoth, Inc. has a policy of continuous improvement and reserves the right to change design and specifications without notice. © 2013 Mammoth, Inc. MAMM-WHSP-PC-1UE January 2013