Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features apc.com apc.com 2 A versatile UPS developed for unstable power conditions worldwide Smart-UPS On-Line provides high-density, double-conversion, online power protection for servers, voice/data networks, medical labs, and light industrial applications. The Smart-UPS On-Line is capable of supporting loads from 2.2 kVA – 10 kVA in a rack/tower convertible chassis. The 6 kVA, 8 kVA, and 10 kVA models feature unity output power factor enabling them to support power-hungry blade servers or heavily loaded equipment racks. When businesscritical systems require runtime in hours, not minutes, Smart-UPS On-Line can be configured with multiple battery packs to meet aggressive runtime demands. TM The included PowerChute Network Shutdown management software provides unattended graceful shutdown of network operating systems. Models 5 kVA to 10 kVA include an integrated network management card for remote management. The entire Smart-UPS On-Line family provides value to customers with demanding power conditions, including a very wide input voltage window, extremely tight output voltage regulation, frequency regulation, internal bypass, and input power factor correction. TM apc.com 3 Smart-UPS On-Line Industry-leading power factor maximizing UPS density Rackmount and Tower SRT 2.2 kVA – 10 kVA Standard Features Best-in-class power density More real power in watts, 0.9 pf on 2.2 kVA – 5 kVA, Unity on 6 kVA – 10 kVA units. High-efficiency “green mode” Achieves 98 percent efficiency, which saves utility and cooling costs without compromising performance or reliability. Graphical LCD display with multicolor backlight Intuitive interface provides detailed and accurate information with ability to configure locally. Intelligent battery management Temperature-compensated charging extends life and advanced algorithms recommend replacement date. The UPS can inform user which batteries need to be replaced and auto detect when additional battery packs are added. Built-in energy meter Measures energy use and displays UPS efficiency in various modes of operation for easy energy tracking. SRT6KXLI shown Operate without battery Ability to immediately protect equipment when power returns after a complete discharge of the battery. Three-year warranty on electronics Additional year of warranty protection for electronics provides peace of mind. apc.com 4 apc.com 5 apc.com 6 Smart-UPS On-Line Proven performance with the world’s largest installed base of single-phase, double-conversion products Rackmount and Tower SRT 2.2 kVA – 10 kVA Additional Features Embedded network management card with environmental monitoring (5 kVA – 10 kVA models) Remote monitoring and control of the UPS and the environment via Ethernet connection while freeing up the SmartSlot so customers can add accessories for additional communication options. TM Switched outlet group(s) Ability to control a group of output load receptacles independent from the main UPS. Enables: • Rebooting hung device without cycling the entire UPS. • Sequenced turn ON/OFF. • Shedding of noncritical loads based on a variety of parameters (battery time, runtime remaining, and overload). • Scheduled time OFF to conserve energy. Emergency power off (EPO) Remote UPS shutoff in the event of a fire or other emergency. The UPS can accept normally open (NO) or normally closed (NC) contacts. Communication ports Serial, USB, Ethernet, and SmartSlot for network accessory cards. SRT10KXLT shown Communication protocols Modbus serial, USB PowerSummary, HTTP, SNMP, and Telnet. 1:1, 3:1 input hard-wire options Product can be wired for 3-PH or 1-PH input (230 V, 8 kVA, and 10 kVA models only). Dual input Enables second input source to be connected to UPS bypass (230 V, 8 kVA, and 10 kVA models only). apc.com 7 Smart-UPS On-Line display Intuitive, easy-to-use LCD provides clear and accurate information in multiple languages Standard Features LCD display screen Accurately provides real-time status updates in your choice of basic or advanced menus. UPS status (scrolling) • Output voltage • Input voltage • Output frequency • Runtime • Load • Battery health Control • UPS and outlet group settings • Bypass control Configuration • Output voltage, frequency • Language, brightness, contrast Backlight screens: Amber: Indication of condition that requires attention • Alarm volume Red: Indication of UPS alarm that requires immediate attention • IP address Test and diagnostics • Initiate battery and runtime calibration tests About • UPS serial number, battery part number • Battery install and suggested replacement dates apc.com 8 Product Accessories SRT009: APC Smart-UPS SRT 5 M extension cable for 72 VDC external battery pack 2.2 kVA UPS Management cards AP9630: UPS network management card with PowerChute network shutdown SRT010: APC Smart-UPS SRT 5 M extension cable for 96 VDC external battery pack 3 kVA UPS AP9631: UPS network management card with PowerChute network shutdown and environmental monitoring Rail kits SRTRK2: APC Smart-UPS SRT 19 inch rail kit for Smart-UPS SRT 5/6/8/10 kVA UPS AP9335TH: APC by Schneider Electric temperature and humidity sensor TM TM Management card SRTRK3: APC 2-post mounting rail kit for Smart-UPS SRT 2.2/3/5/6/8/10 kVA UPS AP9810: APC dry contact I/O accessory SRTRK4: APC Smart-UPS SRT 19 in. rail kit for Smart-UPS SRT 2.2/3 kVA UPS AP9624: UPS interface expander AP9613: Dry contact I/O SmartSlot card Backplate kit SRT001: APC Smart-UPS SRT 5 kVA output HW kit Battery packs SRT192BP: APC Smart-UPS SRT 192 V 5 kVA and 6 kVA battery pack SRT192RMBP: APC Smart-UPS SRT 192 V 5 kVA and 6 kVA RM battery pack SRT192BP2: APC Smart-UPS SRT 192 V 8 kVA and 10 kVA battery pack SRT192RMBP2: APC Smart-UPS SRT 192 V 8 kVA and 10 kVA RM battery pack SRT72BP: APC Smart-UPS SRT 72 V 2.2 kVA battery pack SRT72RMBP: APC Smart-UPS SRT 72 V 2.2 kVA RM battery pack SRT96BP: APC Smart-UPS SRT 96 V 3 kVA battery pack SRT96RMBP: APC Smart-UPS SRT 96 V 3 kVA RM battery pack SRT002: APC Smart-UPS SRT 5 M Extension Cable for 192 VDC External Battery Packs 5/6 kVA UPS SRT003: APC Smart-UPS SRT 5 M Extension Cable for 192 VDC External Battery Packs 8/10 kVA UPS SRT012: APC Smart-UPS SRT 2.2/3 kVA input/output HW kit Battery pack Transformers SURT002: APC Smart-UPS RT 5,000 VA 230 V isolation transformer APTF10K W01: APC W W 10 kVA isolation transformer Service bypass panels SBP6KRMI2U: APC service bypass panel 230 V; 50 A; MBB; hardwire input; (4) IEC-320 C19 Output SBP10KRMI4U: APC service bypass panel 230 V; 100 A; MBB; hardwire input; IEC-320 output (8) C13 (2) C19 Rail kits Other SURT013: SURT Equipment Cart Replacement Battery Cartridge APCRBC140: RBC for SRT 5 kVA - 10 kVA UPS APCRBC141: RBC for SRT 2.2 kVA UPS APCRBC152: RBC for SRT 3 kVA UPS Runtime estimates at half and full load (minutes) SRT2200XLI (RM) (990 W/1,980 W) SRT3000XLI (RM) SRT3000XLW-IEC (RM) (1,350 W/2,700 W) Internal 11.6/3.9 11.8/4.0 11.8/4 8.7/2.5 14.5/5.2 11.5/3.8 (1) Battery pack 45.7/20.2 46.4/20.5 46.2/20.5 36/15.5 34.5/14.7 28/11.6 (2) Battery packs 82.1/37.6 83.3/38.1 83/38 65.2/29.4 55.43/24.63 45.3/19.8 (3) Battery packs 119.9/55.6 121.6/56.3 121/56.4 95.5/43.8 77/34.84 63.1/28.2 (4) Battery packs 158.6/74.1 160.9/75.1 160.4/75.1 126.6/58.6 99.1/45.33 81.3/36.8 UPS half/full loads apc.com SRT5KXLI (RM) SRT5KRMXLW-HW (2,250 W/4,500 W) SRT6KXLI (RM) (3,000 W/6,000 W) SRT8KXLI (RM) (4,000 W/8,000 W) SRT10KXLI(RM) (5,000 W/10,000 W) 9 Smart-UPS On-Line SRT 2200 VA and SRT 3000 VA Technical specifications Product feature SRT2200XLI SRT2200RMXLI SRT3000XLI SRT3000RMXLI SRT3000XLW-IEC SRT3000RMXLW-IEC Output Power rating Nominal output voltage Output frequency 2200 VA/1980 W 3000 VA/2700 W 50/60 Hz ± 3 Hz (auto sense) 50/60 Hz ± 0.1 Hz (user selectable) Topology Double-conversion online Online efficiency at full load (typical) Green mode efficiency at full load (typical) 230 V (208 V, 220 V, 240 V user selectable) 230 V (220 V, 240 V user selectable) 92% 96% 97% Output connections (switched groups) (8) IEC 320 C13 (2) IEC 320 C19 (4) IEC320 C13 (2) IEC320 C19 230 V 230 V (208 V, 220 V, 240 V user selectable) Input Nominal input voltage Input voltage range full load (half load) 160 – 275 V (100 – 275 V) Input frequency 40 – 70 Hz auto-selecting Input connection IEC-60320 C20, Schuko CEE 7/EU1-16P, British BS1363A Batteries and runtime Battery type Maintenance-free sealed lead-acid battery with suspended electrolyte, leak proof Typical backup time at ½ load (min) 11.6 min 11.8 min Typical backup time at full load (min) 3.9 min 4.0 min APCRBC141 (1) APCRBC152 (1) SRT72BP/SRT72RMBP SRT96BP/SRT96RMBP Replacement battery (quantity) External battery pack (tower/rack mount) Communication and management Interface ports Serial (RJ45), USB (Type A) and SmartSlot Control panel High resolution graphical LCD display Emergency power off (EPO) Yes (NO/NC connections) Physical Rack height 85 mm, 2U Maximum width (RM) 432 mm 432 mm Maximum depth (RM) 585 mm 636 mm 25 Kg 31 kg CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2 CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2, UL-1778, FCC Part 15 Class A, CSA Net weight Conformance Regulatory Warranty apc.com Three years electronics/two years battery 10 Smart-UPS On-Line SRT 5 kVA – 10 kVA Product feature SRT5KXLI SRT5KRMXLI SRT5KRMXLW-HW SRT6KXLI SRT6KRMXLI SRT8KXLI SRT8KRMXLI SRT10KXLI SRT10KRMXLI Output Power rating Nominal output voltage Output frequency 5,000 VA/4,500 W 6,000 VA/6,000 W 230 V (220 V, 240 V, 208 V user selectable) 10,000 VA/10,000 W 230 V (220 V, 240 V user selectable) 50/60 Hz ± 3 Hz (auto sense) 50/60 Hz ± 0.1 Hz (user selectable) Double-conversion online Topology Online efficiency at full load (typical) Green mode efficiency at full load (typical) Output connections 8,000 VA/8,000 W 94% 98% Hardwire three-wire (1 PH + N + G) or (2 PH + G) (6) IEC 320 C13 (4) IEC 320 C19 (6) IEC320 C13, (4) IEC320 C19, hardwire three-wire (1 PH + N + G) Input Nominal input voltage 208 V, 220 V, 230 V, 240 V Input voltage range full load (half load) 220 V, 230 V, 240 V 160 – 275 V (100 – 275 V) Input frequency Input connection 220 V/380 V, 230 V/400 V, 240 V/ 415 V 160/277 – 275/476 V (100/173-275/476 V) 40 – 70 Hz auto-selecting Hardwire three-wire (1 Ph+N+G) or (2 PH + G) Hardwire three-wire (1 Ph+N+G) Hardwire three-wire (1 Ph+N+G), Hardwire five-wire (3 Ph+N+G) Batteries and runtime Battery type Maintenance-free sealed lead-acid battery with suspended electrolyte, leak proof Typical backup time at 1/2 load (min.) Typical backup time at full load (min.) Replacement battery (quantity) External battery pack (tower/rack mount) 11.8 min. 8.7 min. 14.5 min. 11.5 min. 4 min. 2.5 min. 5.2 min. 3.8 min. APCRBC140 (1) APCRBC140 (2) SRT192BP/SRT192RMBP SRT192BP2/SRT192RMBP2 Communication and management Interface ports Embedded network management with environmental monitoring which includes an RJ-45 with status LEDs (10/100 Base-T), Control panel High-resloultion graphical LCD display Emergency power off (EPO) Yes (normally open, NO/ normally closed, NC connections) Physical 3U 4U 6U 6U Maximum height (RM) 130 mm 174 mm 263 mm 263 mm Maximum width (RM) 432 mm 432 mm 432 mm 432 mm Maximum depth (RM) 719 mm 719 mm 715 mm 715 mm Net weight 54.5 kg 60 kg 112 kg 112 kg Rack height Conformance Regulatory Warranty apc.com UL-1778, FCC Part 15 Class A, CSA, CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2 CE, VDE, RCM, and EAC, IEC/EN 62040-1, IEC/EN 62040-2 Three years for electronics/two years for battery 11 You are here: Home > Products > Uninterruptible Power Supply (UPS) > Smart­UPS On­Line APC Smart­UPS SRT 3000VA RM 230V Part Number: SRT3000RMXLI Technical Specifications Product Overview Documentation Software & Firmware Options Output Output Power Capacity 2700 Watts / 3000 VA Max Configurable Power 2700 Watts / 3000 VA Nominal Output Voltage 230V Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage Output Voltage Distortion Less than 2% Output Frequency (sync to mains) 50/60Hz +/­ 3 Hz Other Output Voltages 220, 240 Crest Factor 3 : 1 Topology Double Conversion Online Waveform Type Sine wave Output Connections (8) IEC 320 C13 (2) IEC 320 C19 (2) IEC Jumpers Bypass Internal Bypass (Automatic and Manual) Input Nominal Input Voltage 230V Input Frequency 40 ­ 70 Hz (auto sensing) Input Connections British BS1363A IEC­320 C20 Schuko CEE 7/EU1­16P Cord Length 2.44 meters Input voltage range for main operations 160 ­ 275V Input voltage adjustable range for 100 ­ 275 (half load)V mains operation Other Input Voltages 220, 240 Batteries & Runtime Battery Type Maintenance­free sealed Lead­Acid battery with suspended electrolyte : leakproof Included Battery Modules 1 Typical recharge time 3 hour(s) RBC Quantity 1 Nominal Battery Voltage 96V Extended Run Options APC Smart­UPS SRT 3000VA RM 230V Runtime Graph Curve Part Number(s) A SRT3000RMXLI B SRT3000RMXLI + (1)SRT96RMBP C SRT3000RMXLI + (2)SRT96RMBP D SRT3000RMXLI + (3)SRT96RMBP E SRT3000RMXLI + (4)SRT96RMBP Hover over the line on the graph above to view the runtime at any desired load Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph View Runtime Chart Energy Use/Efficiency Load Efficiency 25% 89.9% 50% 92.8% 75% 93.4% 100% 93.5% Hover over the line on the graph above to view the efficiency at any desired load Curve fit of data measured in accordance with the ENERGY STAR Program Requirements Product Specification for Uninterruptible Power Supplies (UPSs) ­ Eligibility Criteria Version 1.0. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph Communications & Management Interface Port(s) RJ­45 Serial, SmartSlot, USB Available SmartSlot™ Interface Quantity 1 Control panel Multi­function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 340 Joules Filtering ­­ Physical Maximum Height 85.00 mm Maximum Width 432.00 mm Maximum Depth 635.00 mm Rack Height 2U Net Weight 31.30 KG Shipping Weight 39.92 KG Shipping Height 246.00 mm Shipping Width 599.00 mm Shipping Depth 871.00 mm Color Black Units per Pallet 6.00 Environmental Operating Environment 0 ­ 40 °C Operating Relative Humidity 0 ­ 95% no% Operating Elevation 0­3000 meters Storage Temperature ­15 ­ 45 °C Storage Relative Humidity 0 ­ 95% no% Storage Elevation 0­15000 meters Audible noise at 1 meter from surface of unit 55.00 dBA Online Thermal Dissipation 703.00 BTU/hr Protection Class IP 20 Conformance Approvals CE, CE Mark, EAC, EN/IEC 62040­1, EN/IEC 62040­2, ENERGY STAR (EU), RCM, VDE Standard warranty 3 years repair or replace (excluding battery) and 2 years for battery Sustainable Offer Status RoHS Compliant REACH REACH: Contains No SVHCs Battery Directive Compliant Battery Notes Contains Lithium Coin Cell **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS. You are here: Home > Products > Uninterruptible Power Supply (UPS) > Smart­UPS On­Line APC Smart­UPS SRT 3000VA 230V Part Number: SRT3000XLI Technical Specifications Product Overview Documentation Software & Firmware Options Output Output Power Capacity 2700 Watts / 3000 VA Max Configurable Power 2700 Watts / 3000 VA Nominal Output Voltage 230V Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage Output Voltage Distortion Less than 2% Output Frequency (sync to mains) 50/60Hz +/­ 3 Hz Other Output Voltages 220, 240 Crest Factor 3 : 1 Topology Double Conversion Online Waveform Type Sine wave Output Connections (8) IEC 320 C13 (2) IEC 320 C19 (2) IEC Jumpers Bypass Internal Bypass (Automatic and Manual) Input Nominal Input Voltage 230V Input Frequency 40 ­ 70 Hz (auto sensing) Input Connections British BS1363A IEC­320 C20 Schuko CEE 7/EU1­16P Cord Length 2.44 meters Input voltage range for main operations 160 ­ 275V Input voltage adjustable range for 100 ­ 275 (half load)V mains operation Other Input Voltages 220, 240 Batteries & Runtime Battery Type Maintenance­free sealed Lead­Acid battery with suspended electrolyte : leakproof Typical recharge time 3 hour(s) RBC Quantity 1 Extended Run Options APC Smart­UPS SRT 3000VA 230V Runtime Graph Curve Part Number(s) A SRT3000XLI B SRT3000XLI + (1)SRT96BP C SRT3000XLI + (2)SRT96BP D SRT3000XLI + (3)SRT96BP E SRT3000XLI + (4)SRT96BP Hover over the line on the graph above to view the runtime at any desired load Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph View Runtime Chart Energy Use/Efficiency Load Efficiency 25% 89.9% 50% 92.8% 75% 93.4% 100% 93.5% Hover over the line on the graph above to view the efficiency at any desired load Curve fit of data measured in accordance with the ENERGY STAR Program Requirements Product Specification for Uninterruptible Power Supplies (UPSs) ­ Eligibility Criteria Version 1.0. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph Communications & Management Interface Port(s) RJ­45 Serial, Smart­Slot, USB Available SmartSlot™ Interface Quantity 1 Control panel Multi­function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 340 Joules Filtering ­­ Physical Maximum Height 432.00 mm Maximum Width 85.00 mm Maximum Depth 635.00 mm Net Weight 31.30 KG Shipping Weight 36.74 KG Shipping Height 246.00 mm Shipping Width 599.00 mm Shipping Depth 871.00 mm Color Black Units per Pallet 6.00 Environmental Operating Environment 0 ­ 40 °C Operating Relative Humidity 0 ­ 95% no% Operating Elevation 0­3000 meters Storage Temperature ­15 ­ 45 °C Storage Relative Humidity 0 ­ 95% no% Storage Elevation 0­15000 meters Audible noise at 1 meter from surface of unit 55.00 dBA Online Thermal Dissipation 703.00 BTU/hr Protection Class IP 20 Conformance Approvals CE, CE Mark, EAC, EN/IEC 62040­1, EN/IEC 62040­2, ENERGY STAR (EU), RCM, VDE Standard warranty 3 years repair or replace (excluding battery) and 2 years for battery Sustainable Offer Status RoHS Compliant REACH REACH: Contains No SVHCs Battery Directive Compliant Battery Notes Contains Lithium Coin Cell **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS. You are here: Home > Products > Uninterruptible Power Supply (UPS) > Smart­UPS On­Line APC Smart­UPS SRT 2200VA RM 230V Part Number: SRT2200RMXLI Technical Specifications Product Overview Documentation Software & Firmware Output Output Power Capacity 1980 Watts / 2200 VA Max Configurable Power 1980 Watts / 2200 VA Nominal Output Voltage 230V Output Voltage Distortion Less than 2% Output Frequency (sync to mains) 50/60Hz +/­ 3 Hz Other Output Voltages 220, 240 Crest Factor 3 : 1 Topology Double Conversion Online Waveform Type Sine wave Output Connections (8) IEC 320 C13 (2) IEC 320 C19 (2) IEC Jumpers Bypass Built­in Bypass Input Nominal Input Voltage 230V Input Frequency 40 ­ 70 Hz (auto sensing) Input Connections IEC­320 C20 Options Schuko CEE 7 / EU1­16P British BS1363A Cord Length 2.44 meters Input voltage range for main operations 160 ­ 275V Input voltage adjustable range for 100 ­ 275 (half load)V mains operation Other Input Voltages 220, 240 Batteries & Runtime Battery Type Maintenance­free sealed Lead­Acid battery with suspended electrolyte : leakproof Included Battery Modules 1 Typical recharge time 3 hour(s) RBC Quantity 1 Extended Run Options APC Smart­UPS SRT 2200VA RM 230V Runtime Graph Curve Part Number(s) A SRT2200RMXLI B SRT2200RMXLI + (1)SRT72RMBP C SRT2200RMXLI + (2)SRT72RMBP D SRT2200RMXLI + (3)SRT72RMBP E SRT2200RMXLI + (4)SRT72RMBP Hover over the line on the graph above to view the runtime at any desired load Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph View Runtime Chart Energy Use/Efficiency Load Efficiency 25% 87.1% 50% 91.1% 75% 92.0% 100% 92.2% Hover over the line on the graph above to view the efficiency at any desired load Curve fit of data measured in accordance with the ENERGY STAR Program Requirements Product Specification for Uninterruptible Power Supplies (UPSs) ­ Eligibility Criteria Version 1.0. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output. View Enlarged Graph Communications & Management Interface Port(s) RJ­45 Serial, Smart­Slot, USB Available SmartSlot™ Interface Quantity 1 Control panel Multi­function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 340 Joules Filtering ­­ Physical Maximum Height 85.00 mm Maximum Width 432.00 mm Maximum Depth 584.00 mm Rack Height 2U Net Weight 25.00 KG Shipping Weight 34.02 KG Shipping Height 246.00 mm Shipping Width 599.00 mm Shipping Depth 810.00 mm Color Black Units per Pallet 12.00 Environmental Operating Environment 0 ­ 40 °C Operating Relative Humidity 0 ­ 95% no% Operating Elevation 0­3000 meters Storage Temperature ­20 ­ 50 °C Storage Relative Humidity 0 ­ 95% no% Storage Elevation 0­15000 meters Audible noise at 1 meter from surface of unit 55.00 dBA Online Thermal Dissipation 535.00 BTU/hr Protection Class IP 20 Conformance Approvals CE, CE Mark, EAC, EN/IEC 62040­1, EN/IEC 62040­2, ENERGY STAR (EU), RCM, VDE Standard warranty 3 years repair or replace (excluding battery) and 2 years for battery Sustainable Offer Status RoHS Compliant REACH REACH: Contains No SVHCs Battery Directive Compliant Battery Notes Contains Lithium Coin Cell **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS. SERBIA AND MONTENEGRO [ Change ] Home Sign in Products and Services Solutions ✉ Share: Support Your Business Company Subscribe to our Channel APC Smart­UPS SRT 6000VA 230V SRT6KXLI APC Smart­UPS SRT 6000VA 230V Includes: CD with software , Documentation CD , Installation guide , Removable support feet , Temperature Probe , USB cable , Warranty card , Web/SNMP Management Card Locate a Partner Related Products, Accessories & Services Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 Product Overview Technical Specifications View all optional accessories for this product Power Cord Kit (6 Ea), C19 To C20 (90 Degree), 0.6m Documentation Software & Firmware Output Output power capacity 6.0 KWatts / 6.0 kVA Max Configurable Power (Watts) 6.0 KWatts / 6.0 kVA Nominal Output Voltage 230V Output Voltage Distortion Less than 2% Output Frequency (sync to mains) 50/60Hz +/­ 3 Hz Other Output Voltages 220, 240 Load Crest Factor 3 : 1 Topology Double Conversion Online Waveform type Sine wave Output Connections Bypass (6) IEC 320 C13 (Battery Backup) (4) IEC 320 C19 (Battery Backup) Internal Bypass (Automatic and Manual) Input Nominal Input Voltage 230V Input frequency 40 ­ 70 Hz (auto sensing) Input Connections Hard Wire 3 wire (1PH+N+G) Input voltage range for main operations 160 ­ 275 V Rack PDU 2G, Switched, ZeroU, 20A/208V, 16A/230V, (7) C13 & (1) C19 Options Input voltage adjustable range for mains operation 100 ­ 275 (half load) V Other Input Voltages 220, 240 Batteries & Runtime Battery type Maintenance­free sealed Lead­Acid battery with suspended electrolyte : leakproof Typical recharge time 1.5 hour(s) Replacement Battery APCRBC140 RBC Quantity 1 Extendable Run Time 1 Battery Volt­Amp­Hour Capacity 902 Extended Run Options APC­Smart­UPS­SRT­6000VA­230V Runtime View Runtime Graph Efficiency View Efficiency Graph View Runtime Chart Communications & Management Interface Port(s) RJ­45 10/100 Base­T , RJ­45 Serial , Smart­Slot , USB Control panel Multi­function LCD status and control console Audible Alarm Audible and visible alarms prioritized by severity Emergency Power Off (EPO) Yes Available SmartSlot™ Interface Quantity 1 Surge Protection and Filtering Surge energy rating 480 Joules Physical Maximum Height 432 , 43.2 CM Maximum Width 174 , 17.4 CM Maximum Depth 719 , 71.94 CM Net Weight 60.0 KG Shipping weight 67.0 KG Shipping Height 370 , 37.0 CM Shipping Width 610 , 61.0 CM Shipping Depth 960 , 96.0 CM Color Black Units per Pallet 6.0 Environmental Operating Environment 0 ­ 40 °C Operating Relative Humidity 0 ­ 95% no % Operating Elevation 0­3000 meters Storage Temperature ­15 ­ 45 °C Storage Relative Humidity 0 ­ 95% no % Storage Elevation 0­15000 meters Audible noise at 1 meter from surface of unit 55.0 dBA Online thermal dissipation 1300.0 BTU/hr Protection Class IP 20 Conformance Approvals CE, CE Mark, EAC, EN/IEC 62040­1, EN/IEC 62040­2, ENERGY STAR (EU), IRAM, RCM, VDE Standard warranty 3 years repair or replace (excluding battery) and 2 years for battery Sustainable Offer Status RoHS Compliant REACH Home Solutions REACH: Contains No SVHCs Products and Services Support Your Business Company ©APC by Schneider Electric Privacy Policy Contact Schneider Electric 132 Fairgrounds Road West Kingston, RI 02892 Phone: 401-789-5735 www.apc.com October 2015 ©2015 Schneider Electric. All Rights Reserved. Schneider Electric, APC, Smart-UPS, PowerChute, SmartSlot, and Life Is On Schneider Electric are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners.• 998-1243569_GMA-US_A This document has been printed on recycled paper