N04: Firetuf® FO Indoor stranded loose tube cable. VDE: U-DQ (ZN) B H Non- metallic fire resistant cable with 6 – 216 fibres Application and installation Application: Railway Tunnels, subways, metro lines. Installation: Indoor and in ducts outdoor Standards EN 187 000, IEC 60794-2, IEC 60794-2-20, IEC 60794-2-21, ISO 11801 2 nd edition, EN 50 173-1 Fire rating IEC 60331-25 (90) IEC 60332-1-2 IEC 60332-3-24 = IEC 332-3C NF C 32-070 C1 IEC 60754-1 IEC 60754-2 IEC 61034-2 BS EN 50200:2000 BS EN 50268-2:2000 *) BS 4066-3:1994 *) LUL fire standard 2-011001-002 Issue A1 Fire resistance: 90 minutes at 750C Single vertical wire test, Vertically-mounted bunched wires and cables Classification tests on cables and cords with respect to their behaviour to fire; test C1 No halogens No acid matters No dense smoke Fire resistance: 120 minutes at 860C, with mechanical shock (1 per 5 minutes) Smoke emission Flammability *) The two tests with acceptance criteria made twice constitute the requirements for Category ST/TU/CA Construction Central strength member ø2.5 or ø3.0 mm FRP rod, depending on tube dimension Lose tube ø2.3 mm jelly filled loose tubes, with 4 – 12 fibres each, up to 18 tubes in two layers, ø2.8 mm jelly filled loose tubes, with 24 fibres each, 6 or 8 tubes. Red Yellow w/mark every 70 mm 1 13 Fibre colour code LINKING THE FUTURE www.prysmiangroup.com N04_e Version 11.2 | 2012-01-02 Page 1 of 3 N04: Firetuf® FO Indoor stranded loose tube cable. VDE: U-DQ (ZN) B H Water blocking 2 Green 14 White w/mark every 70 mm 3 Blue 15 Grey w/mark every 70 mm 4 Yellow 16 Turquoise w/mark every 70 mm 5 White 17 Orange w/mark every 70 mm 6 Grey 18 Pink w/mark every 70 mm 7 Brown 19 Yellow w/mark every 35 mm 8 Violet 20 White w/mark every 35 mm 9 Turquoise 21 Grey w/mark every 35 mm 10 Black 22 Turquoise w/mark every 35 mm 11 Orange 23 Orange w/mark every 35 mm 12 Pink 24 Pink w/mark every 35 mm The core is waterblocked using swellable tape and tread Wrapping Fire blocking tape Reinforcement Heavy layer of E-glass fibre yarns as reinforcement, added fire protection and rodent protection, effective in most cases. Ripcord Polyester ripcord for easy slitting of the sheath Sheath 2 – 2.5 mm FireRes depending on fibre count, standard colour: Blue, UV stabilized, Print legend DRAKA FIRETUF FO I/O ST D DA LSHF-FR 6.0 kN <Fibre count><Fibre type><Fibre brand> <Item No>05<Batch Number><Meter mark> U-DQ(ZN)BH <Number of Elements> x <Fibre count per element> <Fibre family> <Mode field diameter> /125 <Transmission Class> EN 50290-2-27. Physical properties Attribute Fibre count Build [number of tubes x fibres per tube ] Nominal diameter [mm] Nominal weight [kg/km] Short term tensile strength (some days) [N] Permanent tensile strength [N] Crush (compressive strength) [N/100 mm] Impact [J] Torsion Kink IEC 60794-1-2 Method - E1 Limits 72 96 120 144 216 144 192 6 x 12 8 x 12 10 x 12 12 x 12 18 x 12 12 x 24 8 x 24 13.5 210 15.0 250 17.5 330 19.0 400 >6000 19.5 410 15.0 250 18.0 360 E1 E3 >4000 3000 E4 E7 E10 25 5 cycles 1 turn The cables do not form a kink when a loop is drawn together to a diameter 12 times the cable nominal diameter Minimum bending radius [mm] E11 210 250 330 400 410 250 360 -40 C to 70 C Temperature range F1 Installation -40 C to 70 C Operation *) -40 C to 70 C Storage Water penetration F5 No water on free end Heat of combustion [MJ/km] 2500 3200 4400 5600 5300 3000 4700 [kWh/m] 0.69 0.89 1.22 1.56 1.47 0.83 1.31 *) The cables will operate without any attenuation variation (≤0.05 dB) in the temperature interval -30C to +60C. The cables will operate with a maximum attenuation variation of 0.1dB/km in the temperature interval -40C to +70C. LINKING THE FUTURE www.prysmiangroup.com N04_e Version 11.2 | 2012-01-02 Page 2 of 3 N04: Firetuf® FO Indoor stranded loose tube cable. VDE: U-DQ (ZN) B H Product codes – ordering information Prysmian group material code Prysmian Group material description Firetuf Firetuf Firetuf Firetuf Firetuf Firetuf SM2D FO FO FO FO FO FO I/O I/O I/O I/O I/O I/O ST ST ST ST ST ST D D D D D D DA DA DA DA DA DA LSHF-FR LSHF-FR LSHF-FR LSHF-FR LSHF-FR LSHF-FR 6kN 6kN 6kN 6kN 6kN 6kN Draka Material code 6 SM2D 24 SM2D 48 SM2D 72 SM2D 96 SM2D 144 1025675 1025369 1024650 1029526 Fibre count 6 24 (2x12) 48 (4x12 72 (6x12) 96 (8x12) 144 (8x24) Fibre type OS2 OS2 OS2 OS2 OS2 OS2 Single Single Single Single Single Single mode mode mode mode mode mode Fibre data sheet C06e C06e C06e C06e C06e C06e [PRODUCT CODE TABLE] © PRYSMIAN GROUP 2010, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group. LINKING THE FUTURE www.prysmiangroup.com N04_e Version 11.2 | 2012-01-02 Page 3 of 3