Rex - analog time switches Rex - analog time switches MicroRex - 3 modules for DIN rail mounting MicroRex - 1 module for DIN rail mounting 926 428 Reference A10 415 Reference MicroRex T31 24 hour program, synchronous motor MicroRex T11 24 hour program, synchronous motor 910 402 230 V, 50 Hz A10 415 120 V,60 Hz 925 429 230 V, 50 Hz A25 446 120 V, 60 Hz MicroRex QT11 24 hour program, quartz controlled motor (with running reserve) MicroRex W31 7 day program, synchronous motor 916 402 230 V, 50/60 Hz A16 418 120 V, 50/60 Hz 925 112 230 V, 50 Hz A25 114 120 V, 60 Hz MicroRex W11 7 day program, synchronous motor MicroRex QT31 24 hour program, quartz controlled motor (with running reserve) 926 428 230 V, 50/60 Hz A26 448 120 V, 50/60 Hz 926 420 9-48 V, AC/DC MicroRex QW31 7 day program, quartz controlled motor (with running reserve) 926 116 230 V, 50/60 Hz A26 126 120 V, 50/60 Hz 926 113 9-48 V, AC/DC 910 103 230 V, 50 Hz A10 104 120 V, 60 Hz MicroRex QW11 7 day program, quartz controlled motor (with running reserve) 916 102 230 V, 50/60 Hz A16 103 120 V, 50/60 Hz According to UL 60730-1, UL 60730-2-7, IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631 part 2-7 Accessory 037 49 Kit for wall mounting, including base plate and terminal cover According to UL 60730-1, UL 60730-2-7, IEC 730-1, EN 60730-1, VDE 0631 part 1, IEC 730-2-7, EN 60730-2-7, VDE 0631part 2-7 Analog 24 hour and 7 day time switches for DIN rail. Hour and minute hands can be turned clockwise or counter-clockwise, providing easy and quick change of summer to winter time and vice versa. • manual override switch 14 Analog 24 hour and 7 day time switches for DIN rail. • manual override switch Rex - analog time switches MicroRex Technical data analogue MicroRex MicroRex T11 No. of modules (17.5 mm) Motor Switching dial Running reserve Switching step Min. switching step Switching accuracy Accuracy Switching capacity • Resistive 230 V~ cos j =1 • Incandescent lamp 230 V~ • inductive 230 V~ cos j =0.6 Contact Operating temperature Protection MicroRex QT11 synchron quartz 24 h 24 h none >100 h 15 min 15 min 15 min 15 min +/-5 min +/-5 min according to +/- 2.5 sec frequency a day 1 SPST 1 SPST MicroRex MicroRex MicroRex MicroRex MicroRex MicroRex W11 QW11 T31 QT31 W31 QW31 1 3 synchron quartz synchron quartz synchron quartz 7d 7f 24 h 24 h 7d 7d none >100 h none >100 h none >100 h 2h 2h 15 min 15 min 2h 2h 2h 2h 30 min 30 min 4h 4h +/-30 min +/-30 min +/-5 min +/-5 min +/-30 min +/-30 min according to +/- 2.5 sec according to +/- 2.5 sec according to +/- 2.5 sec frequency a day frequency a day frequency a day 1 SPST 16 A~ 4 A~ 12 A~ 1 SPST -10....+55 °C IP20 1 SPDT 1 SPDT 1 SPDT Dimensions Wiring diagrams MicroRex-3 modules 1 SPDT Wall mounting plate for MicroRex 31 2.36” 60 mm 1.73” 44 mm U1 U2 1 4 2 L 0 4.13” 104.9 mm 2.07” 52.6 mm 2.6” 45 mm Type Ref. no. 03749 including terminal cover N MicroRex-1 module 3.94” 60 mm 1.73” 44 mm 1.77” 45 mm 3.39” 86 mm 0.69” 17.5 mm 15 Rex - analog time switches Front panel and wall mounting EconoRex M Technical data Type EconoRex MT synchron Motor Switching dial Running reserve Switching step Min. switching time Switching accuracy Accuracy Switching capacity • Resistive 230 V~ cos ϕ =1 • Incandescent lamps 230 V~ • Inductive 230 V~ cos ϕ =0.6 Contacts Operating temperature Protection Time switch modules with flat plugs for panel mounting (without accessories) EconoRex MT 24 h, without running reserve EconoRex MW synchron 24 h none 912 441 Reference EconoRex MQT quartz 7d >100 h 10 min 20 min +/-5 min according +/-2.5 sec to frequency a day 20 A~ 16 A~ none >100 h 1h 2h +/-30 min according +/-2.5 sec to frequency a day 20 A~ 4 A~ 12 A~ 1 SPDT -10....+55 °C IP30 2.83” 72 mm EconoRex MQT 24 h, with running reserve 1.32” 35.5 mm 0.83” 21mm 2.64” 67 mm 2.83” 72 mm 912 427 230 V, 50/60 Hz A12 464 120 V, 50/60 Hz EconoRex MW 7 day, without running reserve 912 445 230 V, 50 Hz A12 465 120 V, 60 Hz EconoRex MQW 7 day, with running reserve 912 447 230 V, 50/60 Hz A12 466 120 V, 50/60 Hz Wiring diagram Overview Accessories Wall mounting kit for EconoRex M A00 020 includes base plate with terminals and terminal cover A00 021 Adapter for DIN rail mounting U1U2 2 4 1 Isolierung 6,3 x 0,8 According to UL 60730-1, UL 60730-2-7, IEC 730-1, EN 60730-1, VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7 2,5mm2 (I > 16A) L N Compact analog daily or weekly time switch for front panels and surface mounting • with manual override • with 72 x 72 mm display conform to DIN EN 50 022 part C Wall mounting 2.67” 68 mm+0.7 R3 1.49” 38 mm Rear panel 2.12” 54 mm Front panel 1” 2 .7 m m 69 2” 2.1 mm 54 Ref. 495 94 16 16 A~ 4 A~ 12 A~ Dimensions 912 441 230 V, 50 Hz A12 463 120 V, 60 Hz EconoRex MQW quartz Rex - analog time switches MaxiRex 30A NEW A23 460 Technical data Reference A23 460 MaxiRex T 30A Daily time switch, without running reserve 120V, 60Hz A24 460 A24 461 MaxiRex QT 30A Daily time switch, with 100h running reserve 230V, 50/60Hz 120V, 50/60Hz A23 160 MaxiRex W 30A Weekly time switch, without running reserve 120V, 60Hz Type Motor T W synchronous Switching dial 24 h 7d Running reserve none 100h Switching step 10 min 1h 10 min 1h Min. switching time 20 min 2h 20 min 2h Switching accuracy +/- 5 min/d Accuracy A24 160 A24 161 A000 27 Accessory Terminal cover +/- 30 min/d acc. to frequency +/- 1sec/day Switching capacity • Resistive 230 V~ cos j =1 MaxiRex QW 30A Weekly time switch, with 100h running reserve 230V, 50/60Hz 120V, 50/60Hz QT QW quartz controlled 30 A • Incandescent lamps 230 V~ 1800 W • Inductive 230 V~ cos j =0.6 20 A Contacts 1 SPST Operating temperature -10° C... +55° C Protection IP20 According to UL 60730-1, UL 60730-2-7, EN 50022, EN 55014-1, EN 55014-2, IEC 60730-1, EN 60730-1, VDE 0631-1, IEC 60730-2-7, EN 60730-2-7, VDE 0631-2-7. Robust analog daily and weekly time switch with REAL 30 Amp switching capacity, for DIN rail mounting and wall mounting. The MaxiRex 30A is our perfect solution to control your special applications with heavy loads like: • the lighting of commercial billboards / sign boards • water heaters • hydrochlorinators • heating / ventilation systems • post lights • blowers • pool heaters • electric fences • filters, pumps and conveyers Wiring diagram Dimensions with terminal cover 2.83” 72 mm 2.04” 52 mm Dimensions without terminal cover 2.04” 52 mm L POWER N N LOAD L 4.41” 112.2 mm POWER 4.30” 109.4 mm 5.28” 134.2 mm 2.83” 72 mm POWER L N L POWER N N LOAD L 17 Rex - analog time switches defrost time switches PolarRex Technical data Type PolarRex KT synchronous Motor Switching dial Running reserve Switching step PolarRex QKT quartz >100 h Defrost time switches without running reserve PolarRex KT 24 hour, 1 channel A13 469 230V, 50Hz none 1-60 min +/-5 min +/-1 sec according to a day frequency according to frequency Dimensions (mm) PolarRex KKT 24 hour, 2 channel 2.83” 72 mm 20 19 18 17 16 22 12 1 6 min. 8 10 7 6 5 4 5 1 5 30 60 30 60 1 4.47” 113.7 mm 9 10 10 3 2 11 min. 1 PolarRex QKT 24 hour, 1 channel 2.83” 72 mm 3 9 13 12 24 23 14 Defrost time switches with running reserve 2.10” 53.4 mm 15 21 +/-1 sec a day 16 A~ used as NO: 4 A~/used as NC 12 A~ 1 SPDT 2 SPDT -10....+55 °C IP 30 Wiring diagram A13 470 230V, 50Hz A13 475 120V, 60Hz >100 h 30 min Accuracy Switching capacity • Resistive 230 V~ cos ϕ =1 • Inductive 230 V~ cos ϕ =0.6 Contacts Operating temperature Protection Reference PolarRex QKKT quartz 24 h none Min. switching time Switching accuracy (switching dial) A13 469 PolarRex KKT synchronous 2 1 STOP 2 L N 1 2 3 4 5 6 A19 450 230V, 50/60 Hz N L PolarRex QKKT 24 hour, 2 channels 1.75” 44.4 mm A19 447 230V, 50/60Hz A19 448 120V, 50/60Hz Programming According UL 60730-1, UL 60730-2-7, IEC 730-1, EN 60730-1, VDE 0631-1, IEC 730-2-7, EN 60730-2-7, VDE 0631-2-7. The time switch has a 24h dial and one (1 channel) or two (2 channel) continuously adjustable short time programs, which can repeated several times in 24h. The program’s duration has to be adjusted with a button which is dedicated to a specific channel. The start of the program has to be set on the dial by pulling a segment on the desired time. The shortest duration between 2 programs is 30 min. The short time program can be repeated up to 48 times in 24h. The beginning, the duration and the number of the programs can be changed easily without any accessories. Programming the defrost times and visualization of the working status with 2 green LED’s Different types of mounting: • DIN rail • wall DIN-rail Wall mounting 1. ” 28.512 mm 60 5 10 1 60 1 5 60 30 10 30 5 1 60 1 5 10 30 30 10 3.50” 89 mm .137” x 1.57” 3.5mm x 40mm .137” x 1.18” 3.5mm x 30mm 18 Rex - analog time relays A63 207 A63 206 Reference Reference A63 222 Star-Delta relay A63 208 Multi-function relay In addition to the afore mentioned functions (except the flashing relay) the multifunctional relay offers you the following functions: A63 205 ON-delay relay ON/OFF delay Control input Y1 Control input Y1 Contact Contact A63 204 OFF-delay relay Flasher (impulse starting) Control input Y1 Control input Y1 Contact Contact A63 209 Clock generator relay (impulse starting) Flasher (off-time starting) Control input Y1 Control input Y1 Contact Contact A63 207 Impulse former relay Passing contact Control input Y1 Control input Y1 Contact Contact A63 206 Flashing relay Additive ON delay Control input Y1 Control input Y1 Contact Contact Additive fleeting ON According to UL 60730-1, UL 60730-2-7, VDE 0631-1 and 0631-2-7, EN 60 730-1 and 60 730-2-7 Control input Y1 Contact Application: To control single timer functions like: illumination, ventilation, automation, control systems . . . • sealable cover • supply voltage: 12 V...230 V AC 19 Rex - analog time relays Technical data Type No. of modules (17.5 mm) Supply voltage Power consumption Precision of const. parameters Setting accuracy Switching capacity • Resistive 230 V cos ϕ =1 • Incandescent lamps 230 V • Inductive 230 V cos ϕ =0.6 Contacts 7 domains of time: 1 12....230 V AC/DC ca. 2 W +/- 0.2% of adjusted value +/-5% at 25 °C 8 A~ 2 A~ 4 A~ 1 Channel min. 0,1 s – 1s – 10 s – 1 min. – 10 min. – 1h – 10 h – 0.69” 17.5 mm 105 switching at 2000 VA 107 mechanical switching 3.94” 60 mm 1.73” 44 mm 20 m -20....+60 °C IP20 Functions and switching diagrams ON-delay relay A63 205 1.77” 45 mm Multifunctional relay (A63 208) additionally to the previous mentioned functions, (except flashing relay) the multifunctional relay offer the following functions: ON/OFF delay Control input Y1 Control input Y1 Contact Contact OFF-delay A63 204 Flasher (impulse starting Control input Y1 Control input Y1 Contact Contact Clock generator relay A63 209 Flasher (OFF-time starting) Control input Y1 Control input Y1 Contact Contact Impulse former relay A63 207 Passing contact Control input Y1 Control input Y1 Contact Contact Flashing relay A63 206 Additive ON delay Control input Y1 Control input Y1 Contact Contact Additive fleeting ON Control input Y1 Contact 20 max. 1s 10 s 100 s 10 min. 100 min. 10 h 100 h Dimensions 3.27” 83 mm No. of cycles Max. admissible length of control wire Operating temperature Protection Wiring diagram Time relays Hour counters Front panel, Din-rail, flush-mounting ContaRex 495 54 908 106 907 239 Dimensions ContaRex 48x48 Reference ContaRex 48 x 48 front panel 120 V, 60 Hz 230 V, 60 Hz 10 - 80 V, DC 1.77" 45 mm 495 54 495 57 495 60 ContaRex 36 x 24 front panel 907 239 230 V, 60 Hz 1.89" 48 mm According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1 • square 48 x 48 mm, IP 40 • 55 x 55 adapter included (48 x 48 mm version) • AC-version: = 0 to 99999.99 h • DC-version: = 0 to 999999.9 h • front panel mounting 0006723 h .23" 6 mm 1.77" 45 mm 1.26" 32 mm Reference ContaRex round, Ø 80 mm 495 63 10...80 V ±10% 1.89" 48 mm 2.16" 55 mm 1.77" 45 mm 1.96" 50 mm DC ContaRex ø 80mm .078" 2 mm Accessories 2" 51 mm 3.14" 80 mm .7" 18 mm ContaRex 36x24 .944" 24 mm .866"x1.29" 22mm x33mm According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1 • round, Ø 80 mm, IP 67 • protected against vibrations by a rubber buffer ring • DC-version: 0 to 99999.9 h • front panel mounting 2.79 71 mm -0/+1 908 105 Frame 72 x 72 mm 908 106 Frame 55 x 55 mm 1.41" 36 mm .31" 8mm 2.16" 55 mm 21 Hour counters Din-rail mount Rex 2000 HC2 961 103 Dimensions Reference Rex2000 HC2 According to UL 863, cUL C22.2, IEC 1010-1, EN 61010-1, VDE 0411 part 1 Analog modular hour run indicator in for DIN rail mounting • easy and quick mounting on DIN rail by using the 2 locking clamps • sealable cover 22 1.4” 35.6 mm 1.73” 44 mm 1.77” 45 mm 230 V, 60 Hz 120 V, 60 Hz 24 V, 50 Hz 12-36 V DC 3.27” 83 mm 961 102 961 103 961 104 A61 108 3.94” 60 mm