1 Relay Modules in DIN-Rail Mounted Enclosure 152 Voltage (V) Relay with 1 changeover contact (1 u) Nominal input voltage VN 24 V DC Relay with 1 changeover contact (1 u) Nominal input voltage VN 24 V DC, 230 V AC/DC 300 200 resistive load 100 50 40 30 20 10 0.1 0.2 0.5 1 2 5 10 20 Current (A) 14 14 A2 – A2 – Other coil voltages contact factory A2 ~ A2 ~ 11 Description VN IN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 19 mA 789-304 1 Technical Data Contact material Input voltage range Max. switching voltage Max. make current (resistive) at a 10 % duty cycle Max. continuous current Max. Switching power (resistive) Recommended minimum load Operating power Pull-in/drop-out/bounce time typ. Nominal operating mode Dielectric strength contact-coil (AC, 1 min) Dielectric strength open contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Mechanical life at 1000 W, AC 250 V Service life at lamp load Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals 12 A1 ~ 12 A1 + 11 VN IN Item No. Pack. Unit 24 V AC/DC 230 V AC 20 mA 4.2 mA 789-504 789-508 1 1 Accessories see page 162 Accessories see page 162 AgNi 90/10 VN -15 % ... +10 % 250 V AC/DC 4 s 25 A (AC) 12 A 3000 VA AC, DC see load limit curve > 100 mA / 12 V AC/DC 400 mW 7 ms / 3 ms / 3 ms continuous duty 5 kV 1 kV 250 V / 4 kV / 3 AgNi 90/10 VN -15 % ... +10 % 250 V AC/DC 4 s 25 A (AC) 12 A 3000 VA AC, DC see load limit curve > 100 mA / 12 V AC/DC 0.96 VA 15 ms / 15 ms / 3 ms continuous duty 5 kV 1 kV 250 V / 4 kV / 3 30 x 106 switching operations 1.2 x 103 switching operations -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts) 30 x 106 switching operations 1.2 x 103 switching operations -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts) 1 153 Voltage (V) Relay with 2 changeover contacts (2 u) Nominal input voltage VN 24 V, 48 V, 110 V DC 300 Relay with 2 changeover contacts (2 u) Nominal input voltage VN 24 V AC/DC, 115 V, 230 V AC 1 2-pole resistive load 200 2 contacts in serie 100 1 contact 50 40 30 20 10 0.1 0.2 0.5 1 2 5 10 20 Current (A) Other coil voltages contact factory A1 + 14 12 24 22 A2 – A2 – 21 11 14 12 24 22 A1 ~ A2 ~ A2 ~ 21 11 Description VN IN Item No. Pack. Unit VN IN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 48 V DC 110 V DC 21 mA 13 mA 6 mA 789-312 789-313 789-315 1 1 1 24 V AC/DC 115 V AC 230 V AC 22 mA 7.6 mA 4.2 mA 789-512 789-515 789-516 1 1 1 Technical Data Contact material Input voltage range Max. switching voltage Max. make current (resistive) at a 10 % duty cycle Max. continuous current Max. Switching power (resistive) Recommended minimum load Operating power Pull-in/drop-out/bounce time typ. Nominal operating mode Dielectric strength contact-coil (AC, 1 min) Dielectric strength open contact Dielectric strength contact-contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Mechanical life Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals Accessories see page 162 Accessories see page 162 AgNi 90/10 VN -15 % ... +10 % 250 V AC/DC 4 s / 15 A 8A 2000 VA AC, DC see load limit curve > 100 mA / 12 V AC/DC 400 mW 7 ms / 2 ms / 3 ms continuous duty 5 kV 1 kV 2.5 kV 250 V / 4 kV / 3 AgNi 90/10 VN -15 % ... +10 % 250 V AC/DC 4 s / 15 A 8A 2000 VA AC, DC see load limit curve > 100 mA / 12 V AC/DC 0.96 VA 7 ms / 2 ms / 3 ms continuous duty 5 kV 1 kV 1.5 kV 250 V / 4 kV / 3 3 x 107 switching operations -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts) 5 x 106 switching operation -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts) 1 Relay Modules in DIN-Rail Mounted Enclosure 154 Contact voltage (V) Relay with 4 make contacts (4 a) Nominal input voltage VN 24 V DC Relay with 4 make contacts (4 a) Nominal input voltage VN 12 V, 24 V AC/DC 1000 DC resistive load AC resistive load 100 10 0.1 1 10 Contact current (A) 14 24 34 44 14 24 34 44 A1 + A1 ~ A2 – A2 – A2 ~ A2 ~ 13 23 33 43 Description VN IN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 12 mA 789-352 1 Technical Data Contact material Input voltage range Max. switching voltage Max. switching current Max. Switching power (resistive) Recommended minimum load Pull-in/drop-out/bounce time typ. Nominal operating mode Max. switching frequency with load Dielectric strength contact-coil (AC, 1 min) Dielectric strength open contact Dielectric strength contact-contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals 13 23 33 43 VN IN Item No. Pack. Unit 12 V AC/DC 24 V AC/DC 21 mA 12 mA 789-551 789-552 1 1 Accessories see page 162 Accessories see page 162 AuAg10 over AgNi 15 VN -15 % ... +10 % 250 V AC / 30 V DC 4 A AC / 3 A DC 1000 VA / 90 W, resistive see load limit curve > 100 μA / 100 mV DC 15 ms / 10 ms / 1 ms continuous duty 6 min-1 1.5 kV 0.75 kV 1 kV 230 V / 2.5 kV / 3 AuAg10 over AgNi 15 VN -15 % ... +10 % 250 V AC / 30 V DC 4 A AC / 3 A DC 1000 VA / 90 W, resistive see load limit curve > 100 μA / 100 mV DC 20 ms / 20 ms / 1 ms continuous duty 6 min-1 1.5 kV 0.75 kV 1 kV 230 V / 2.5 kV / 3 -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0110 Part1 / 4.97 IEC 60 664-1; DIN VDE 0435 (corresp. parts), EN 61 810 -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0110 Part1 / 4.97 IEC 60 664-1; DIN VDE 0435 (corresp. parts), EN 61 810 1 155 Contact voltage (V) Relay with 2 break and 2 make contacts (2 ar) Nominal input voltage VN 24 V DC Relay with 2 break and 2 make contacts ( 2 ar) Nominal input voltage VN 12 V, 24 V AC/DC 1 1000 DC resistive load AC resistive load 100 10 0.1 1 10 Contact current (A) Note:Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! 14 24 12 22 14 24 12 22 A1 + A2 – A2 – A1 ~ A2 ~ A2 ~ 13 23 11 21 Description VN IN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 12 mA 789-336 1 Technical Data Contact material Input voltage range Max. switching voltage Max. switching current Max. Switching power (resistive) Recommended minimum load Pull-in/drop-out/bounce time typ. Nominal operating mode Max. switching frequency with load Dielectric strength contact-coil (AC, 1 min) Dielectric strength open contact Dielectric strength contact-contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals 13 23 11 21 VN IN Item No. Pack. Unit 12 V AC/DC 24 V AC/DC 21 mA 12 mA 789-535 789-536 1 1 Accessories see page 162 Accessories see page 162 AuAg10 over AgNi 15 VN -15 % ... +10 % 250 V AC / 30 V DC 4 A AC / 3 A DC 1000 VA / 90 W, resistive see load limit curve > 100 μA / 100 mV DC 15 ms / 10 ms / 1 ms continuous duty 6 min-1 1.5 kV 0.75 kV 1 kV 230 V / 2.5 kV / 3 AuAg10 over AgNi 15 VN -15 % ... +10 % 250 V AC / 30 V DC 4 A AC / 3 A DC 1000 VA / 90 W, resistive see load limit curve > 100 μA / 100 mV DC 20 ms / 20 ms / 1 ms continuous duty 6 min-1 1.5 kV 0.75 kV 1 kV 230 V / 2.5 kV / 3 -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0110 Part1 / 4.97 IEC 60 664-1; DIN VDE 0435 (corresp. parts), EN 61 810 -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0110 Part1 / 4.97 IEC 60 664-1; DIN VDE 0435 (corresp. parts), EN 61 810 1 Relay Modules in DIN-Rail Mount Enclosure Switching current (A) 156 Relay with 1 changeover contact (1 u), manual configuration, electrical and mechanical activation indicator Relay with 2 changeover contacts (2 u), manual configuration, electrical and mechanical activation indicator Similiar to picture Similiar to picture 1 change over contact 2 change over contacts Switching voltage (V) 14 12 A1 + Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. A2 – VN Relay module in DIN 35-rail mount enclosure 24 VDC Technical Data Coil Input voltage range Contacts Contact material Max. continuous current Max. make current (resistive) at a 10 % duty cycle Max. switching voltage Max. Switching power (resistive) Pull-in/drop-out/bounce time typ. Mechanical life General specifications: Nominal voltage to EN 60664 Dielectric strength contact-coil Surge capacity open contact Dielectric strength contact-contact (AC, 1 min.) Ambient operating temperature (VN) Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Standards/Specifications (OT = On-time) A2 – 11 Description IN Item No. 789-1341 14 12 24 22 A1 + Pack. Unit VN 24 VDC IN 21 11 Item No. 789-1346 Accessories see page 162 Accessories see page 162 UN -10% ... +10 % UN -10% ... +10 % AgNi 12 A 16 A 250 VAC 3000 VA AC 15 ms / 8 ms / 5 x 106 switching operations AgNi 2x8A 8A 250 VAC 2 x 2000 VA AC 15 ms / 8 ms / 5 x 106 switching operations 250 V / 4 kV / 3 5 kV eff 1 kV eff -25 °C ... +50 °C -40 °C ... +70 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in EN 60664-1 250 V / 4 kV / 3 5 kV eff 1 kV eff 1.5 kV eff -25 °C ... +50 °C -40 °C ... +70 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in EN 60664-1 Pack. Unit 1 Relay Modules in DIN-Rail Mount Enclosure 157 Switching current (A) Relay with 1 changeover contact (1 u), manual configuration, electrical and mechanical activation indicator Relay with 2 changeover contacts (2 u), manual configuration, electrical and mechanical activation indicator 1 change over contact 2 change over contacts Switching voltage (V) Similiar to picture 14 12 A1 ~ Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts. A2 ~ Description VN Relay module in DIN 35-rail mount enclosure 230 Technical Data Coil Input voltage range Contacts Contact material Max. continuous current Max. make current (resistive) at a 10 % duty cycle Max. switching voltage Max. Switching power (resistive) Pull-in/drop-out/bounce time typ. Mechanical life General specifications: Nominal voltage to EN 60664 Dielectric strength contact-coil Surge capacity open contact Dielectric strength contact-contact (AC, 1 min.) Ambient operating temperature (VN) Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Standards/Specifications (OT = On-time) IN A2 ~ 11 Item No. 789-1544 14 12 24 22 A1 ~ Pack. Unit VN 230 IN 21 11 Item No. 789-1549 Accessories see page 162 Accessories see page 162 UN -10% ... +10 % UN -10% ... +10 % AgNi 12 A 16 A 250 VAC 3000 VA AC 15 ms / 8 ms / 5 x 106 switching operations AgNi 2x8A 8A 250 VAC 2 x 2000 VA AC 15 ms / 8 ms / 5 x 106 switching operations 250 V / 4 kV / 3 5 kV eff 1 kV eff -25 °C ... +50 °C -40 °C ... +70 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in EN 60664-1 250 V / 4 kV / 3 5 kV eff 1 kV eff 1.5 kV eff -25 °C ... +50 °C -40 °C ... +70 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in EN 60664-1 Pack. Unit 1 1 Relay Modules in DIN-Rail Mounted Enclosure 158 Latching relay with 1 make contact (1 a) Nominal input voltage VN 24 V DC Lamp load: max. load 1500 W Fluorescent lamp, dual circuit: max. load 20 x 58 W series compensated Electronic ballasts: 10 x 58 W Latching relay with 1 make contact (1 a) Nominal input voltage VN 230 V AC A1 + 14 A1 ~ 14 A2 – 13 A2 ~ 13 Description VN IN Item No. Pack. Unit VN IN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 42 mA 789-571 1 230 V AC 10 mA 789-570 1 Technical Data Contact material Input voltage range Max. switching voltage Min. switching current Max. switching current Max. continuous current Max. Switching power (resistive) Minimum switch-on time Minimum break time Coil control Fuse protection Nominal operating mode Max. switching frequency with load Max. switching frequency without load Dielectric strength contact-coil (AC, 1 min) Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Mechanical life Mechanical life at max. load (resistance) Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals Accessories see page 162 Accessories see page 162 AgCdO VN -15 % ... +10 % 400 V AC 0.1 A 50 A (20 ms) 16 A 4000 VA AC / 300 W DC 40 ms 180 ms Impuls circuit breaker max. 16 A B-charakteristic continuous duty 6 min-1 4 s-1 4 kV 250 V / 4 kV / 3 AgCdO VN -15 % ... +10 % 400 V AC 0.1 A 50 A (20 ms) 16 A 4000 VA AC / 300 W DC 40 ms 180 ms Impuls circuit breaker max. 16 A B-charakteristic continuous duty 6 min-1 4 s-1 4 kV 250 V / 4 kV / 3 1 x 105 switching operations 5 x 104 switching operations -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts); DIN VDE 0632 1 x 105 switching operations 5 x 104 switching operations -25 °C ... +40 °C -40 °C ... +85 °C 17.5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 and IEC 60255; DIN VDE 0435 (corresp. parts); DIN VDE 0632 1 159 Relay with 1 make contact (1a), manual-0-automatic switch Capability of different lamp loads: (switching operations acc. to EN 60669) Current (A) 1 100 AC resistive load 10 1 10 100 1000 Voltage (V) (+24V) Note:Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! A1 + A3 + A 0 1 A = Automatisk 0 = OFF 1 = Manuell PA 14 A2 A2 - 13 13 Description VN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 789-323 1 Technical Data Contact material Input voltage range Current input at rated voltage (coil 20 °C) Max. switching voltage Max. make current Max. continuous current Max. Switching power (resistive) Recommended minimum load Operating power Pull-in/drop-out/bounce time typ. Nominal operating mode Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to VDE 0110 Part 1/4.97, IEC 60664-1 Mechanical life Mechanical life at max. load (resistance) Mechanical life at max. lamp load Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Approvals Accessories see page 162 Ag-Legierung VN -15 % ... +20 % 19 mA 250 V AC 120 A at 230 V AC (50 ms) 16 A 4000 VA AC, resistance see load limit curve > 100 mA / 12 V AC/DC 400 mW 15 ms / 5 ms continuous duty 4 1 250 V / 4 kV / 3 10 x 106 switching operations min. 100.000 switching operations see "Lamp loads" table -25 °C ... +40 °C -40 °C ... +70 °C 17,5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0140 part 1, DIN EN 61140; DIN VDE 0160, EN 50178; degree of protection II Type of load Capability Electrical life Incandescent lamp Halogen lamp 230 V AC Halogen trafo Fluorescent lamp not comp., CB, cos ϕ 0,4-0,6 Fluorescent lamp comp., Conv. ballast, C parallel Fluorescent lamp comp., Conv. ballast, Duo-circuit Fluorescent lamp with electronic ballast Energy saving lamp 15 W Energy saving lamp 13 W Energy saving lamp 9 W Gas discharge lamp Dulux-Lamp not compensated Dulux-Lamp compensated Max. capacitance at 230 V AC 2200 W 1400 W 120 VA 20 x 58 W 9 x 58 W 600 W 12 x 58 W 25 pcs 30 pcs 38 pcs 1000 W 800 W 500 W 60 µF 20.000 50.000 20.000 25.000 25.000 20.000 25.000 20.000 20.000 20.000 20.000 20.000 20.000 min. 5.000 1 Relay Modules in DIN-Rail Mounted Enclosure 160 Switching current (A) Relay with 1 make contact (1 a), manual-0-automatic switch with monitoring contact Capability of different lamp loads: (switching operations acc. to EN 60669) 100 AC resistive load 10 DC resistive load 1 10 100 1000 Switching voltage (V) (+24V) Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! A1 + A3 + B1 A 0 1 A = Automatic (AUTO) 0 = OFF 1 = Manual ON (MAN) 14 n.c. B2 A2 A2 - 13 13 Description VN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 789-325 1 Technical Data Contact material Input voltage range Current input at rated voltage (coil 20 °C) Max. switching voltage Max. make current Max. continuous current Max. Switching power (resistive) Recommended minimum load Operating power Pull-in/drop-out/bounce time typ. Nominal operating mode Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to IEC 60664-1 Mechanical life Mechanical life at max. load (resistance) Mechanical life at max. lamp load Signaling Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Standards/Specifications (OT = On-time) Accessories see page 162 Ag alloy VN -15 % ... +20 % 19mA 250 V AC 120 A at 230 V AC (50 ms) 16 A 4000 VA AC, resistance see load limit curve > 100 mA / 12 V AC/DC 400 mW 15 ms / 5 ms / continuous duty 4 kV eff 1 kV eff 250 V / 4 kV / 3 10 x 106 switching operations min. 100.000 switching operations see "Lamp loads" table Isolated monitoring contact (B1/B2 closed in automatic mode; max. 1 A, 250 V AC) -25 °C ... +40 °C -40 °C ... +70 °C 17,5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 EN 50178, degree of protection II Type of load Capability Electrical life Incandescent lamp Halogen lamp 230 V AC Halogen trafo Fluorescent lamp not comp., CB, cos ϕ 0,4-0,6 Fluorescent lamp comp., Conv. ballast, C parallel Fluorescent lamp comp., Conv. ballast, Duo-circuit Fluorescent lamp with electronic ballast Energy saving lamp 15 W Energy saving lamp 13 W Energy saving lamp 9 W Gas discharge lamp Dulux-Lamp not compensated Dulux-Lamp compensated Max. capacitance at 230 V AC 2200 W 1400 W 120 VA 20 x 58 W 9 x 58 W 600 W 12 x 58 W 25 pcs 30 pcs 38 pcs 1000 W 800 W 500 W 60 µF 20.000 50.000 20.000 25.000 25.000 20.000 25.000 20.000 20.000 20.000 20.000 20.000 20.000 min. 5.000 1 Relay Modules in DIN-Rail Mounted Enclosure 161 Switching current (A) Relay with 1 changeover contact (1 u), manual-0-automatic switch with switch position monitoring Capability of different lamp loads: (switching operations acc. to EN 60669) 1 100 AC resistive load 10 DC resistive load 1 10 100 1000 Switching voltage (V) (+24V) Note: Inductive loads have to be attenuated by an appropriate protective circuit in order to protect relay coils and contacts! A1 + A3 + A 0 1 A = Automatic (AUTO) 0 = OFF 1 = Manual (MAN) 14 12 B1 11 B3 A2 A2 - Description VN Item No. Pack. Unit Relay modules in DIN-rail mounted enclosure, for DIN 35 rail 24 V DC 789-329 1 Technical Data Contact material Input voltage range Current input at rated voltage (coil 20 °C) Max. switching voltage Max. make current Max. continuous current Max. Switching power (resistive) Recommended minimum load Operating power Pull-in/drop-out/bounce time typ. Nominal operating mode Dielectric strength contact-coil Surge capacity open contact Nominal voltage acc. to IEC 60664-1 Mechanical life Mechanical life at max. load (resistance) Mechanical life at max. lamp load Signaling Ambient operating temperature Storage temperature Dimensions (mm) W x H x L Wire connection Cross sections Stripped lengths Standards/Specifications (OT = On-time) Accessories see page 162 Ag alloy VN -15 % ... +20 % 19mA 250 V AC 120 A at 230 V AC (50 ms) 12 A 4000 VA AC, resistance see load limit curve > 100 mA / 12 V AC/DC 400 mW 15 ms / 5 ms / continuous duty 4 kV eff 1 kV eff 250 V / 4 kV / 3 10 x 106 switching operations min. 100.000 switching operations see "Lamp loads" table Switch position monitoring (B1 = automatic, B3 = manual; max. 1 A, 24 V DC) -25 °C ... +40 °C -40 °C ... +70 °C 17,5 x 55 x 90 Height from upper-edge of DIN 35 rail CAGE CLAMP® 0.08 mm² ... 2.5 mm² / AWG 28 ... 14 5 ... 6 mm / 0.22 in DIN VDE 0160 EN 50178, degree of protection II Type of load Capability Electrical life Incandescent lamp Halogen lamp 230 V AC Halogen trafo Fluorescent lamp not comp., CB, cos ϕ 0,4-0,6 Fluorescent lamp comp., Conv. ballast, C parallel Fluorescent lamp comp., Conv. ballast, Duo-circuit Fluorescent lamp with electronic ballast Energy saving lamp 15 W Energy saving lamp 13 W Energy saving lamp 9 W Gas discharge lamp Dulux-Lamp not compensated Dulux-Lamp compensated Max. capacitance at 230 V AC 2200 W 1400 W 120 VA 20 x 58 W 9 x 58 W 600 W 12 x 58 W 25 pcs 30 pcs 38 pcs 1000 W 800 W 500 W 60 µF 20.000 50.000 20.000 25.000 25.000 20.000 25.000 20.000 20.000 20.000 20.000 20.000 20.000 min. 5.000 1 Accessories, 789 Series 162 Push-in type jumper bars Commoning Description Push-in type jumper bars Operating tool uninsulated, 12-way, to be cut to the required length Wire connection Description Marking pen Operating tool, with partially insulated shaft Miniature quick marking card 10 strips with 10 markers, white with black printing Pack. Unit 789-112 100 (4x25) Marking pen with fibre tip Item No. Pack. Unit 210-110 210-720 1 1 Item No. Pack. Unit plain 248-501 5 cards 1 ...10 (10 x) 11 ... 20 (10x) 21 ... 30 (10x) 31 ... 40 (10x) 41 ... 50 (10 x) 1 ... 50 (2 x) K 1 ... K 10 (10 x) K 11 ... K 20 (10 x) K 100 (10 x) U 1 ... U 10 (10 x) U 11 ... U 20 (10 x) U 100 (10 x) 248-502 248-503 248-504 248-505 248-506 248-566 248-450 248-451 248-452 248-453 248-454 248-455 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards 5 cards for permanent marking Type 2, blade (3.5 x 0.5) mm Marking Description Miniature WSB Quick marking system Marking software and printer/plotter see Section 8 Marking Item No.