www.terraluxillumination.com TRK-R16 LED Track Luminaire Product Specification INTRODUCTION The TerraLUX TRK-R16 LED track head makes it easy to replace halogen luminaires on Halo®1 track systems. With performance equivalent to 50W MR-16 halogen lamps, the TRK-R16 is equipped with TerraLUX’s LEDSense® closed-loop thermal control that maximizes light output while assuring long-term lumen maintenance. An easily accessible push button on the front allows selection of 4 different light output modes and light distribution can be quickly modified on site by swapping the front lens. FEATURES Equivalent to 50W MR-16 halogen lamp >= 50 lm/W 4 lighting levels (equivalent to 50W, 35W and 20W halogen plus a lower mode @25%) easily selected via a push button 4 available color temperatures : 2700K, 3000K, 3500K and 4000K with CRI>80 3 different distributions (19°, 34° and 60°), field replaceable. Compatible with Halo®1 track systems Patented LEDSense® Thermal Management ensures reliability and lumen maintenance L70 = 60,000 hours 5-year warranty ENERGY STAR® Certified UL listed luminaire (cULus) FCC Class A RoHS Compliant 1. Halo® is a registered trademark of Cooper Lighting TerraLUX TRK-R16 Product Specification (06/12/2013) Subject to change without notice 1 www.terraluxillumination.com PERFORMANCES Notes: 1) Typical Performance @ 25°C ambient . All specifications subject to tolerance of ± 10% 2) All information consistent with IESNA LM-79-08 testing, completed by a qualified third party facility 3) All measurement taken in Mode 1 (High), for other modes check the matrix here : 4) Dimmer should only be used in Mode 1 (High) PHOTOMETRY Relative Candela Distribution (3000K) Narrow: 19° Wide Flood: 60° Flood: 34° Illumination at a Distance (3000K) Mounting Height Diameter Mounting Height In feet FC In feet In feet 6 78.7 2.1 8 44.3 2.8 10 28.3 12 19.7 14 16 Diameter Mounting Height FC In feet In feet FC In feet 6 30.0 4.0 6 11.3 10.4 8 16.9 5.4 8 6.3 13.9 3.4 10 10.8 6.7 10 4.1 17.3 4.1 12 7.5 8.1 12 2.8 20.8 14.4 4.8 14 5.5 9.4 14 2.1 24.2 11.1 5.5 16 4.2 10.8 16 1.6 27.7 TerraLUX TRK-R16 Product Specification (06/12/2013) Subject to change without notice Diameter 2 www.terraluxillumination.com LEDSense® OPERATION, THERMAL DERATING, & LUMEN MAINTENANCE The TRK-R16 employs TerraLUX’s patented LEDSense® Thermal Management Technology to automatically provide maximum light output in various fixtures and operating conditions while assuring long-term lumen maintenance. LEDSense® regularly measures the operating temperature and ensures compliance with a pre-programmed temperature and drive-current profile. This profile is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000 hour lumen maintenance curves. LEDSense® is always active, and will compensate for variation in thermal conditions due to heatsinking, ambient air, module positioning, or any other variable that affects the operating temperature. The Thermal De-rating curve below identifies the relative light output that can be expected under various thermal conditions. The LEDSense® Power Curve identifies the reduction in input power over temperature. . TerraLUX TRK-R16 Product Specification (06/12/2013) Subject to change without notice 3 www.terraluxillumination.com TESTS AND CERTIFICATIONS Product Safety Certifications Radio Frequency Emissions Reduction of Hazardous Substances (RoHS) Electro-Static Discharge Power Factor Drop Test Shipping / Transit Operating Temperature Storage Temperature Lumen Maintenance Long Term Operation (Module) Input Voltage Range TerraLUX TRK-R16 Product Specification (06/12/2013) • UL Standard 1574:2008 Track Lighting Systems •FCC Part 15, Unintentional Radiators Class A. Sec 107, Conducted Emissions - 0.15MHz – 30MHz Sec 109, Radiated Emissions - 30 MHz – 8000MHz •Industry Canada Notice ICES-003: Class A Digital Apparatus • European Council Directive 2002/95/EC, (including amendments 2005/618/EC, 2005/717/EC and 2005/747/EC) on the restriction of certain hazardous substances in electrical and electronic equipment. •± 4kV and ± 6kV contact discharge •±8kV and ± 10kV air gap discharges 0.92 @ 12 V AC (high mode) Drop from a distance of 1 meter onto a non-resilient test floor. The test surfaces shall be the face, two opposing sides, the base, and two opposing top corners. Operation is to be checked after each impact. International Safe Transit Association (ISTA) Project 2A. -40°C to +45°C, 0 to 95% R.H. / 157 hr. -40°C to +85°C / 60 hr. followed by 20°C to 85°C, 5 to 95% R.H. / 80 hr. L70 =60,000hr per IES TM-21-11 (Based on LED Manufacturer’s measurement per IES LM-80-08 @ 10.000hrs). MBTF = 70,000 hours (TerraLUX TLM-R16C light engine) 108-132V AC Subject to change without notice 4 www.terraluxillumination.com PRODUCT SELECTION & PART NUMBER GUIDE * Indicates the typical level of light output in “high” mode as compared to a Halogen source. 1. Halo is a registered trademark of Cooper Lighting 4. 19° and 34° lenses included with the fixture, 60° lens available as optional accessory Push button enables switching between the four lumen output modes (50W, 35W, 20W equivalent and 25%). Setting selected is stored in memory and device automatically switches on to that mode after power has been cycled. Three distributions are offered : 19° (Narrow— included lens), 34° (Flood—included lens) and 60° (Wide Flood—optional lens). Distribution can easily be changed on-site by placing the appropriate lens. TerraLUX TRK-R16 Product Specification (06/12/2013) Subject to change without notice 5 www.terraluxillumination.com MECHANICAL DIMENSIONS CONTACT INFORMATION TerraLUX, Inc. 1830 Lefthand Circle Suite B Longmont, CO 80501 TerraLUX TRK-R16 Product Specification (06/12/2013) Phone: 303-442-4960 E-mail: OEMsales@TerraLUX.com www.TerraLUXillumination.com Subject to change without notice 6