PowerMonic

advertisement
PowerMonic
Portable Power Monitoring
PM30/40
• Voltage Investigations
• Troubleshooting
• Harmonic Analysis
• Power Factor Surveys
• Load Studies
The PowerMonic range
of portable recorders
offers effective, reliable
and versatile monitoring
of low voltage circuits.
The high performance
rugged PowerMonic is a
workhorse instrument for
conducting power quality
and supply compliance
studies, equipment operation
analyses, power flow and
power factor assessments
and load surveys, as well as
troubleshooting and locating
hard-to-find intermittent faults.
T&D Solutions Since 1974
PowerMonic
Portable Power Monitoring
The PowerMonic series of portable power
quality recorders caters to a wide range of
utility and industrial monitoring applications.
The high powered, robust, easy to use and
practical instrument provides convenient and
accurate information on the performance and
condition of low voltage networks.
The compact design allows for easy and quick
installation for short and long term monitoring
applications. Simultaneously logging Power
Quality and Power Flow parameters the
PowerMonic also independently captures
high speed event snapshots to help uncover
PM30/40
intermittent, potentially harmful and hard-tofind power quality issues. Typical installations
include, but are not limited to, Pad Mount
and Pole Mount Transformers, Capacitor Banks,
Regulators, Substations, and Commercial,
Residential and Industrial connection points.
The PowerMonic Portable Power Quality
Analyzers are a proven, versatile and reliable
everyday instrument used by System Planners,
Distribution Engineers, Electrical Engineers,
Electrical Contractors, Power Quality Engineers,
and Maintenance Engineers for troubleshooting
and analyzing low voltage networks.
The PowerMonic is Easy as 1, 2, 3…
1. Configuration:
Simply Pick, Apply and Install.
Choose from an extensive list
of predefined configurations
accommodating a wide range of
connections or customize to suit a specific
investigation. The configurable options
include:
Simple user defined log parameters
Independent High Speed Event Capture settings
Memory Management
Different Start / Stop log options
The powerful memory management tool allows
the user to allocate memory independently for
events and data, therby maximizing overall
recording time.
3. Data Analysis:
2. Installation:
The PowerMonic’s tamperproof
and rugged housing is well suited
for indoor and outdoor single, split
and three-phase installations.
The PowerMonic features an easy plug and play set
up for immediate use; on connection it automatically
detects, scales and starts recording. The instrument
is powered by the measured voltage, ideal for short
and long-term monitoring without worrying about
battery life or an auxiliary power supply. Real-time
measurements and log and memory status are
clearly displayed on the LCD panel. An internal,
rechargeable backup battery provides ride through
recording capabilities and the non-volatile memory
guarantees data retention during sustained outages.
The logged data is easily downloaded to a PC using
either a direct or remote connection.
PowerView incorporates over
10-years experience and user
feedback and is recognized as the
best in class software package. PowerView
features powerful viewing and reporting tools
with a simple, clean, intuitive and easy-to-use
interface for quick data and root cause analysis.
Included with PowerMonic
Unlimited installations
Free updates, web training and support
VOLTAGE & CURRENT
POWER FACTOR
RMS EVENT CAPTURE
WAVEFORM CAPTURE
Technical Specifications
Measurement
Samples Per Cycle
Sample Rate
Memory
Logged Parameters
Calculated Parameters
Total Harmonic Distortion
Harmonics (Magnitude & Angle)
Interharmonics
Flicker (Pst & Plt)
Voltage & Current Unbalance
High Speed Event Recording
Table Capture (Sags/Swells)
RMS Snapshot
Waveform Snapshot
Display
Communications
PM30
228@50Hz, 190@60Hz
11413Hz, fixed
4MB Internal flash
V, A, Min/Max, Freq, TPf, DPf
kV, kVA, kVAR
Yes
Up to 48th
No
No
No
PM40
204@50Hz, 170@60Hz
PPL Synchronized
15MB Internal, 512MB SD Card
V,A,Min/Max,Freq, TPf, DPf, kV, kVA, kVAR
None
IEC61000-4-7 (THD-F & THD-R)
IEC61000-4-7 (Up to 48th)
IEC61000-4-7 (Up to 48th)
IEC61000-4-15 (10min Pst and 2hr Plt)
IEC61000-4-30
Half Cycle, Min/Max & Duration
Half Cycle, 13s duration
Sample rate,120ms duration
LCD, 2-rows x 16 characters
RS232 (115Kbps)
Half Cycle, Min/Max & Duration
Half Cycle, 5s - 30s duration
Sample rate, 400ms duration
Graphic LCD 128 x 64 bits
USB1.1 (Local) & RS232 (Remote)
General Specifications
Input Channels
Measurement Range
Input Range
Instrument Accuracy
System Accuracy
Resolution Data/LCD Display
Instrument Type
Frequency Range
Current Transformer Burden
Power Source
Power Consumption
Dimensions
Weight
Environmental & Safety
Temperature Range
Humidity
Protection Class
Protection Levels
Voltage
Current
3 (isolated)
4
55-520 VAC
0-3000 Amps
55-520 VAC (600V RMS isolation) 0-440mV at 10K Ohms
0.4% readings + 1 lsd
0.4% readings + 1 lsd
0.4% readings + 1 lsd
1% readings + 1 lsd (0.5M CT)
0.001 Volt/ 0.1 Volt
0.001 Amp/ 0.1 Amp
Class B (IEC 61000-4-30)
50Hz (42.5-57.5Hz), 60Hz (51.0-69.0Hz)
2.2 Ohm + 1% (if applicable)
Main - Phase A, 55-520 VAC, Backup 6V 0.5Ah Battery
10VA typical
9.1”(23cm) x 4.72”(12cm) x 3.6”(9cm)
7lbs (3kg) instrument only
GridSense Inc.
5757 W Century Blvd Ste 815
Los Angeles, CA 90045, USA
-4F (-20C) to +130F(+60C)
20% to 99% RH
IP65 (Weatherproof)
IEC 61010-1 2001, Pollution Degree 2, Insullation Category III,
Material Group III, 600V, Measurement Category III 440V
Tel: +1 310 645-0755
Fax: +1 310 645-0923
CHK GridSense Pty Ltd.
Unit 3 20-36 Nancarrow Av
Meadowbank, NSW 2114, Australia
Current and Power (On/Off)
60-Sec RMS profile (I & E-Field)
FLICKERLine Loading
HARMONIC ANALYSIS
Pre-event
Fault Current Magnitude up to 25KA
Fault Current Waveform (12-cycles)
E-Field Waveform % Change (12-cycles)
Post-event Line Loading
Time to Trip
Number of Trips
Inrush Current
Time of Power-Off
Time of Power-On and Outage Period
User defined averaged profile (1-60 mins) of Load,
Conductor & Ambient Temperatures up to +257F (+125C)
Current
1200Hz,provides
E-Field 600Hz
PowerView
user-friendly graphical and
Current +1% of reading +2 A, Temp + 1 DegF
tabular
viewing
of
logged
data (strip charts), power
Rolling partitioned memory
quality
statistics and high speed event snapshots
100+
events
34including motor starts, transients and momentary
Upand
to 85
days
sustained
outages. The data can easily be
4.4lbs (2kg)
exported to spreadsheets and other data analysis
tools for further manipulation and analysis.
Tel: +61 2 8878-7700
Fax: +61 2 8878-7788
www.gridsense.net
CHK Gridsense PM40 - Datasheet
CHK Gridsense PM40 Power Quality Analyser
CHK,PM40PQA (8779)
Weatherproof IP65 field unit. Channels: 3 voltage, 63 to 440V (isolated). 4 current 0 to 3,000A (3ph and
neutral) RMS. Supplied with 4 flexible 3,000A clamp-on CTs (flexible CT length 600mm and Diameter
190mm). Memory: 15Mb. Inbuilt Graphic 128 x 64bit LCD display, 7 rows x 20 characters. Records: V,
A, pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics, voltage and current imbalance (THD and individual
to 48th), and Flicker. Total energy, tariffs, maximum demands, and transient and sub-cycle disturbances.
Included software provides graphs and summaries to PC. Download files while logging USB interface. A
PC using Windows 95, 98, NT4, WIN2000 or XP O/S is required with the CHK PowerView software to
configure this unit before operating.
Related products that will enhance testing capability
CHK Three Phase
Converter for CTs 5 A
Input to 200 mA Output
CHK,CK5 (8785)
CHK CK1 1A:200 mA
3 Phase Converter Kit
CHK,CK1 (8791)
CHK PM30 Powermonic
Power Logger
CHK,PM30 (8788)
CHK PM45 Power
Quality Analyser
CHK,PM30 (8779)
Save your time and reduce your costs by using our data management services. Learning to operate unfamiliar equipment
costs you time and can lead to fundamental errors in data capture processing. There is a better solution - our setup and
download service.
Our technical staff are equipped and trained to deliver you the downloaded data in a range of suitable output formats including USB drive,
CD-ROM, printout, chart and DVD according to your need and the product’s functionality. Save your time and reduce your real costs.
Contact TechRentals to find out about our Configuration and Download solutions.
If you don’t see the type of equipment you are looking for, contact us to discuss your requirements.
techrentals
your rental business partner
RENT FOR A DAY, A MONTH,
A YEAR OR MORE
Download