ISSUE 15 PLUS+ Lovato Electric. The Story of a Family, the Spirit of a Company Lovato Electric is a proud family owned business established in Bergamo, Italy in 1922: the starting point of a great industrial adventure. Our family of products feature a full range of devices for a wide array of industry sectors: Industrial Control, Power Factor Correction, Solar Energy, Power Generation and Energy Management. We are proud to serve the UK market with a vast stockholding and UK starter assembly in Stourbridge, West Midlands for same day collection or next day delivery. From here we also exclusively distribute Canalplast trunking, Cabur cable terminals and Elca transformers. See 1000’s of our other products in our latest General Catalogue or online at www.Lovato.co.uk MOTOR CONTROL PROTECTION CONTROL AND SIGNALLING CIRCUIT ISOLATION PROTECTION Sales, Technical Support and Customer Care Tel 08458 110 023 or 01384 899700 Fax 08458 110 024 or 01384 891654 Email sales@lovato.co.uk Online Information www.Lovato.co.uk UK Head Office Address Lovato Electric Ltd Lovato House Providence Drive STOURBRIDGE DY9 8HQ AUTOMATION AND CONTROL ENERGY MANAGEMENT 1- Enclosed Direct On-line Starters - Polycarbonate Enclosed Star-Delta Starters - Polycarbonate Thermal Overload Relays Enclosed Star-Delta Starters - Mild Steel Manual Motor Starters Soft Starters AC Motor Drives 3 Pole Contactors and Polycarbonate Enclosures Modular Contactors Enclosed Pushbutton Control Stations Enclosed Switch Disconnectors DC Switch Disconnectors for Solar Applications Steel Enclosed Switches, Fuse Switches & Changeovers Enclosed Changeover Switches - Plastic Rotary Cam Switches Empty Enclosures Limit Switches Signal Towers & Beacons Power Supplies 1-1 1-1 1-2 1-2 1-3 1-4 1-4 1-5 1-5 1-6 1-7 1-7 1.8 1-9 1-9 1-9 1-10 1-11 1-12 2- CBD Series Feed-Through Terminal Blocks CBC Series Feed-Through Terminal Blocks Two & Three Level Terminal Blocks Fused Terminal Blocks Earth Terminal Blocks High Current Terminal Blocks Distribution Terminals Marker Tags End Stops, Covers & Brackets 2-1 2-2 2-3 2-3 2-3 2-3 2-3 2-4 2-4 3- Standard Slot Panel Trunking Narrow Slot Panel Trunking ‘EDGE’ Angular Panel Trunking Halogen Free Panel Trunking DIN Size Panel Trunking Flexible Open Slot Trunking Trunking Accessories Spiral Wrap 3-1 3-2 3-2 3-3 3-3 3-4 3-4 3-4 4 - Open-type Panel Transformers Part-enclosed Panel Transformers 4-1 4-2 The products illustrated in this publication are subject to revision or improvement at any time. Catalogue descriptions, technical and operational data as well as other details herein specified do not have any contractual value and must be considered only as an indication. The products must be installed and used only by qualified personnel in accordance with the relevant regulations in force for electrical installations and systems in order to avoid damage or safety hazards. E.&E.O. Direct On-line Starters Order Code Control Voltage (VAC) Motor Power at 400V (kW) Horse Power (HP) Max. Motor Current AC3 (A) Dimensions HxWxD (mm) Compact Direct On Line Starter (3 Phase) - Requires RF9… Overload Relay BEST PRICE! DOLC5.5230 230 DOLC5.5400 400 DOLC….. 230 DOLS5.5400 400 DOLS7.5230 230 DOLS7.5400 400 DOLS11230 230 DOLS11400 400 DOLS15230 230 DOLS15400 400 Insulated polycarbonate enclosure Operating temperature: -25...+60oC Storage temperature: -40...+70oC Degree of protection: IP65 (IP40 for DOLR…) 5.5 7.5 12 175 x 88 x 119 Certifications and compliance - Starters Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 Standard Direct On Line Starter (3 Phase) - Requires RF38… Overload Relay DOLS5.5230 Operational Characteristics - Starters 5.5 7.5 12 193 x 88 x 134 *** IMPORTANT!!! *** 7.5 10 18 11 15 25 193 x 88 x 134 For DOL starters select RF…. overload relay from page 1-2 for setting motor at full load current (FLC) 225 x 110 x 148 15 20 28.5 Standard Direct On Line Starter With Isolator (3 Phase) - Requires RF38… Overload Relay DOLS…. DOLSW5.5230 230 DOLSW5.5400 400 DOLSW7.5230 230 DOLSW7.5400 400 DOLSW11230 230 DOLSW11400 400 5.5 7.5 12 7.5 10 18 11 15 25 225 x 110 x 148 Direct On Line Reversing Starter FWD/STOP/REV (3 Phase) - Requires RF38… O/L Relay DOLSW…. Star-Delta Starters DOLR5.5230 230 DOLR5.5400 400 DOLR7.5230 230 DOLR7.5400 400 DOLR11230 230 DOLR11400 400 Order Code Control Voltage (VAC) 5.5 7.5 12 7.5 10 18 11 15 25 Motor Power at 400V (kW) Horse Power (HP) Max. Motor Current AC3 (A) 225 x 110 x148 Dimensions HxWxD (mm) YD…. 230 YD11400 400 YD15230 230 YD15400 400 YD22230 230 YD22400 400 YD30230 230 YD30400 400 YDSW…. 1-1 230 YDSW11400 400 YDSW15230 230 YDSW15400 400 YDSW22230 230 YDSW22400 400 YDSW30230 230 YDSW30400 400 Operating temperature: -25...+60oC Degree of protection: IP65 11 15 22 Certifications and compliance - Starters Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 15 20 28 22 30 43 *** IMPORTANT!!! *** 30 40 60 For YD…. Star Delta Starters select RF38…. overload relay from page 1-2 for setting at 58% of full load current (FLC) 220 x 280 x 170 Star Delta Starter With Isolator - Requires RF38… Overload Relay YDSW11230 Insulated polycarbonate enclosure Storage temperature: -40...+70oC Star Delta Starter - Requires RF38… Overload Relay YD11230 Operational Characteristics - Star Delta Starters 11 15 22 15 20 28 22 30 43 30 40 60 220 x 280 x 170 Thermal Overload Relays Adjustment Range (A) Order Code Three Phase Motor at 400V Star Delta (kW) RF9 Overload Relay for use with DOLC…. Starters only RF9 1 RF9…. Three Phase Motor at 400V DOL (kW) Operational Characteristics - Thermal Overload Relays Operating temperature: -20...+55oC (RF9) Operating temperature: -25...+60oC (RF38) Storage temperature: -50...+70oC 0.6 -1 0.37 *** RF9 1V5 0.9 -1.5 0.55 *** RF9 2V3 1.4 - 2.3 0.75 *** RF9 33 2 - 3.3 1.1 *** RF9 5 3-5 1.5 *** RF9 75 4.5 - 7.5 2.2 *** RF9 10 6.3 - 10 4.0 *** RF9 15 9 - 15 5.5 *** Phase Failure Sensitive Single Phase Sensitive Certifications and compliance - Starters Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 RF38 Overload Relay for use with DOLS, DOLSW.,DOLR ,YD and YDSW Star Delta Starters RF38…. RF38 0100 0.63 - 1 0.25 *** RF38 0160 1 - 1.6 0.55 *** RF38 0250 1.6 - 2.5 0.75 *** RF38 0400 2.5 - 4 1.5 2.2 - 3 RF38 0650 4 - 6.5 2.2 4 RF38 1000 6.3 - 10 4 5.5 - 7.5 RF38 1400 9 - 14 5.5 11 RF38 1800 13 - 18 7.5 15 RF38 2300 17 - 23 11 18.5 RF38 3200 24 - 32 15 22 RF38 3800 32 ~ 38A 18.5 30 Indicated powers apply to 4-Pole motors; it is advisable to always check the nameplate motor current is within the relay adjustment range. Steel Enclosed Star-Delta Starters Order Code Control Voltage (VAC) Motor Power at 400V (kW) Horse Power (HP) Max. Motor Current AC3 (A) Dimensions HxWxD (mm) Hinged door mild steel enclosure with painted finish and supplied complete with fitted thermal overload relay and isolator. Operational Characteristics Operating temperature: -25...+60oC Star Delta Starter With Isolator - Overload included Storage temperature: -40...+70oC SDSI 11415 400 11 15 22 SDSI 15415 400 15 20 28 SDSI 22415 400 22 30 42 SDSI 30415 400 30 40 56 SDSI 45415 400 45 60 83 SDSI 55415 400 55 75 98 SDSI 75415 400 75 100 135 Degree of protection: IP65 300 x 300 x 200 Certifications and compliance - Starters Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 500 x 400 x 200 SDSI... 1-2 Manual Motor Starters Thermal Trip Adjustment Range Order Code Short Circuit Breaking Capacity (IEC) at 400V (A) Icu Ics (kA) (kA) IEC Breaking Capacity Icu at 400V: 100kA (0.1 - 6.3A) / 4kA (10 - 25A) at 400V / 6kA (6.3 - 10A) 11 LMS25…. 11 LMU... 11 LMH11 General Characteristics - LMS25 Range The LMS25 manual motor starter is particularly suitable for controlling small operating machines. Releases and auxiliary contacts make it also suitable for more complex uses. Wall and flush-mount enclosures all to install the LMS25 starter in the most disparate environmental conditions (dust, humidity, aggressive environmental agents etc.) Operational Characteristics - LMS25 Range 11 LMS25 016T 0.1 - 0.16 100 100 11 LMS25 025T 0.16 - 0.25 100 100 IEC rated insulation voltage Ui: 690V. IEC rated impulse withstand voltage: 6kV. IEC rated frequency: 50/60Hz 11 LMS25 04T 0.25 - 0.4 100 100 Power dissipation: 2 - 15W. Magnetic tripping: 12In max 11 LMS25 063T 0.4 - 0.63 100 100 IEC thermal tripping class: 10 11 LMS25 1T 0.63 - 1 100 100 11 LMS25 1V6T 1 - 1.6 100 100 11 LMS25 2V5T 1.6 - 2.5 100 100 11 LMS25 4T 2.5 - 4 100 100 11 LMS25 6V3T 4 - 6.3 100 100 11 LMS25 10T 6.3 - 10 6 3 11 LMS25 16T 10 - 16 4 2 11 LMS25 20T 16 - 20 4 2 11 LMS25 25T 20 - 25 4 2 Order Code Phase failure/Single phase sensitive Mechanical life: 100,000 cycles. Electrical life 25A (IEC AC3): 100,000 cycles Mounting on 35mm DIN rail (IEC/EN 60715) or screw fixing IEC utilisation category: A. IEC degree of protection: IP20 Certifications and Compliance - LMS25 Range Certifications obtained: GOST: UL Listed for USA and Canada (File E155982). See UL/CSA details under NOTE below bottom table. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2 IEC/EN 60947-4-1, UL508, CSA C22.2 n° 14 NOTE: When more than one breaker are mounted, side by side, without leaving space between each to consent free air circulation on the breaker sides, and have simultaneous operation, the thermal trip adjuster must be positioned at a value 15% greater than the rated motor current. Characteristics Add-on Auxiliary Contacts. Side Mount 11 LMH 11 11 LMZ106 Operational Characteristics ADD-ON AUXILIARY CONTACTS 1NO + 1NC Undervoltage Trip Release 11 LMU ❶ Connectable to right or left side of starter To fit inside starter. For all LMS25 Maximum combination: 2 x LMH blocks, one on right and one on left side of starter. (4 auxiliary contacts max in total) To fit inside starter. For all LMS25 IEC rated insulation voltage Ui: 500V. IEC conventional free air thermal current Ith: 6A Shunt Trip Release 11 LMA ❶ Enclosures 11 LMZ 111 Surface mount - IP55. 80mm/3.15” wide 11 LMZ 113 Flush mount - IP55. 85mm/3.35” wide IEC operational current AC15: 3.5A 230V; 2A 400V Protection fuse (gL or gG): 6A maximum Conductor cross section minimum-maximum (1 or 2 wires): 0.75-2.5mm2 or 18/14AWG Red Emergency Stop Button - IP55 Protection 11 LMZ 106 11 LMZ111 Width of the auxiliary contacts LMH... equal to 0.5 standard DIN43880 modules. For LMZ 111 and LMZ 113 - Turn to release Ø 35mm/1.38” ❶ Specify rated voltage. Add suffix 60 if frequency is 60Hz. Available voltages: - AC 50Hz 24/48/110/220-240 (indicate 220) 380 - 415 (indicate 380)/ 440 - 460 (indicate 440)/ 480 - 575VAC NOTE - An extensive range of accessories can be found in our latest General Catalogue. UNDERVOLTAGE AND SHUNT TRIP RELEASES Must be fitted inside the motor starter. Maximum UL/CSA Horsepower Rating Type Thermal adjustment range ❷ 3 Phase (HP) 1 Phase (HP) ❸ FLA max at 600V (A) 120V 230V 200-208V 230V 480V 600V (A) LMS25 016T 0.1 - 0.16 — — — — — — 0.16- LMS25 025T 0.16 - 0.25 — — — — — — 0.25 LMS25 04T 0.25 - 0.4 — — — — — — 0.4 LMS25 063T 0.4 - 0.63 — — — — — — 0.63 LMS25 1T 0.63 - 1 — — — — — ½ 1 LMS25 1V6T 1 - 1.6 — — — — ¾ ¾ 1.6 LMS25 2V5T 1.6 - 2.5 — ⅙ ½ ½ 1 1½ 2.5 LMS25 4T 2.5 - 4 ⅛ ¼ ¾ 1 2 3 4 LMS25 6V3T 4 - 6.3 ¼ ½ 1½ 1½ 3 5 6.3 LMS25 10T 6.3 - 10 ½ 1 2 3 5 7½ 10 LMS25 16T 10 - 16 1 2 3 5 10 10 16 LMS25 20T 16 - 20 1½ 3 5 5 10 15 20 LMS25 25T 20 - 25 2 3 5 7½ 15 20 25 NOTE: UL Listed in USA and Canada as manual motor controller. Fuses only 30A suitable for use on a circuit capable of delivering not more than 5000rms symmetrical amperes, 600VAC. Trip current is 125%. ❷ The appropriate thermal trip range of the controller should be selected on the basis of the motor nameplate full-load current since the horsepower ratings given are for indication and reference purposes only. ❸ Single-phase horsepower ratings are based on wiring the three poles in series. 1-3 Release range Operating range On-load factor Undervoltage Shunt 0.35 - 0.7Us 0.85 - 1.1Us 100% — 0.7 - 1.1Us — SURFACE MOUNT ENCLOSURE Top or bottom entry: M25 threaded knockouts Rear entry: 15.5mm/0.6” knockouts Operating termperature: -5...+40°C. Storage termperature: -50...+80°C. FLUSH MOUNT ENCLOSURE Window size 70x115mm/2.76x4.53” Operating termperature: -5...+40°C. Storage termperature: -50...+80°C. Certifications and Compliance - Accessories Certifications obtained: GOST for all; UL Listed for USA and Canada (File E155982), under motor controllers, for auxiliary contacts and trip releases. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1, UL508, CSA C22.2 n° 14. Soft Starters Order Code IEC Rated Starter Current Ie in AC-53b Rated Motor Power (A) IEC (kW) UL/CSA (HP) With Integrated By-pass Relay. 110-400VAC Auxiliary Supply. Three-phase 400VAC Motor Control. General Characteristics ADXC… is a compact type of soft starter, 45mm wide and easy to use, for three phase squirrel-cage induction motors; soft starts and soft stops rated motor load currents up to 45A. It is based on a current limiting starting methodology to limit the maximum starting current. ADXC… reduces the mechanical load on motor shafts, gearboxes and drive belts. Ramp up, ramp down and initial voltage time settings can be independently adjusted by built-in potentiometers. Main features are: ADXC 012 400 12 5.5 3 ADXC 016 400 16 7.5 7.5 ADXC 025 400 25 11 10 For 3ph induction motors up to 22kW / 25HP at 400VAC ADXC 032 400 32 15 15 Maximum input voltage: 400VAC 50/60Hz ADXC 037 400 37 18.5 20 Built-in bypass relay ADXC 045 400 45 22 25 Wrong phase sequence and over temperature protection We offer an extensive range of soft starters which can be found in our latest General Catalogue, or our website or contact our sales office for more information. Current Control ADXC… gradually increases the current limit at 75% ramp-up time if the motor speed has yet to reach rated value, to avoid locked rotor state before time elapsing ADXC….. Alarm for wrong phase sequence; line voltage and/or frequency out of limits (over and undervoltage); overcurrent, over temperature, irregular ramp up and current flow during bypass; motor voltage unbalance Simple setting and installation 2 relay outputs for alarms (NC) and bypass closing 35mm DIN rail mounting (IEC/EN 60715) Ideal for hydraulic lifts, conveyor belts, compressors, pumps, hoisting devices, blowers, fans, mixers. Operational characteristics Number of controlled phases: 2 Input voltage L1-L2-L3: 220-400VAC -15%...+10% ADXC…. Adjustments Frequency range: 50/60Hz ±10% self-configurable Separate single phase auxiliary power supply A1-A2: Start command: A1-A2 110…400VAC -15%...+10% Ramp up time: 1-20 secs, Ramp down time: 0-20 secs 3 x Alarm indication LEDs A Initial voltage : 0-85% of motor control power Degree of protection: IEC IP20. B Ramp Up Time: 1-20 seconds, Initial to max load voltage time. C Ramp Down Time: 0-20 seconds. Max to no load voltage time. AC Motor Drives Order Code Output Current (A) Dimensions WxHxD Output Power (kW) (HP) (mm) VE1 02 A240 1.8 0.2 0.25 VE1 04 A240 2.6 0.4 0.54 VE1 07 A240 4.3 0.75 1 VE1 15 A240 7.5 1.5 2 VE1 22 A240 10.5 2.2 3 Working temperature: -10…+40°C (50°C with fan or 20% current de-rating) Relative humidity: 95% Built-in EMC filter 1° Environment, Category C2 (EN61800) Group 1, Class A (EN55011) 72 x 131 x 139 118 x 131 x 147 NOTE: 5cm minimum required for side by side installations. CD software and instruction manual included. VE1 Description Control mode: V/f (6 fixed curves, 1 programmable). Torque boost Digital input/outputs: 5 programmable inputs (pNp), 1 programmable output (250VAC/1A - 30VDC/1A) Analogue input/outputs: 1 input - 0...10V, 0/4...20mA 1 output - 0...10V Output frequency setting: Front panel (▲▼ keys or potentiometer), Digital inputs (8 selections, with independent acceleration/deceleration times), Communication protocol Motor start and stop: Front panel (RUN and STOP keys), Digital inputs (2 or 3 wire control) Built-in communication port: RS485 (RJ45), modbus RTU and modbus ASCII Accessories VEX C00 General Characteristics Output frequency range: 0...650Hz Input: Single phase 200...240VAC Output: 3-phase 0...240VAC - 0...650Hz (EMC filter built-in) Order Code Certifications and compliance Certifications obtained: UL Listed for USA and Canada (cULus – File E223223) under Solid State Motor Controllers as reduced voltage starters; EAC and CCC pending completion at time of catalogue printing. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-2, UL 508, CSA C22.2 n°14. RS485 (RJ45) - PC (USB) Connection Cable IP protection: IP20 Further technical data is available on our website www.Lovato.co.uk or contact our sales office. We offer an extensive range of AC motor drives which can be found in our latest General Catalogue or contact our sales office for more information. 1-4 Three-pole Contactors Order Code IEC Operating Current Ith AC1 (≤ 40°C) (A) Ie (AC3) ≤ 440V at ≤ 55°C (A) Incorporated Auxiliary Contacts Type of Terminal 11BG09 10 A*** 20 9 1 N/O Clamp-screw 11BG12 10 A*** 20 12 1 N/O Clamp-screw 3 Pole Contactors with AC Control Circuit BF09A to BF25A Quick connect - snap on accessory mounting Distinct contact status indication DC versions also available Screw or 35mm Din rail fixing (IEC/EN 60715) BF09 10 A*** 25 9 1 N/O Clamp-screw BF12 10 A*** 28 12 1 N/O Clamp-screw BF18 10 A*** 32 18 1 N/O Clamp-screw BF25 10 A*** 32 25 1 N/O Clamp-screw BF26 00 A*** 45 26 — Clamp-screw BF32 00 A*** 56 32 — Clamp-screw BF38 00 A*** 60 38 — Clamp-screw DC Versions also available 11 BF50 00*** 90 50 — Allen-screw Screw or 35mm Din rail fixing (IEC/EN 60715) 11 BF65 00*** 110 65 — Allen-screw Certifications - UL, CSA (Canada only), GOST, CCC, RINA 11 BF80 00*** 125 80 — Allen-screw General Characteristics and Certifications - BF50 to BF110 Contactors 11 BF95 00*** 125 95 — Allen-screw 11 BF110 00*** 125 110 — Allen-screw *** Complete with AC coil voltage 50/60Hz - 024, 110, 230, 400V BF50 - BF110 Operating temperature: -40...+60oC Storage temperature: -55...+70oC 3 Pole Mini-contactors with AC Control Circuit BG Contactors General Characteristics and Certifications - BG Mini-contactors Certificates - UL, GOST, CCC General Characteristics and Certifications - BF09 to BF38 Contactors Operating temperature: -50...+70oC Storage temperature: -60...+80oC Quick connect - snap on accessory mounting Four terminal coil Operating temperature: -50...+70oC Storage temperature: -60...+80oC Quick connect - snap on accessory mounting Add-on Blocks for BG Type Mini-contactors DC Versions also available 11 BGX10 11 Screw Type Auxiliary Contact 1NO + 1NC Screw or 35mm and 75mm Din rail fixing (IEC/EN 60715) 11 BGX10 02 Screw Type Auxiliary Contact 2NC 11 BGX10 20 Screw Type Auxiliary Contact 2NO Certifications - UL, CSA (Canada only), GOST, CCC, RINA (except BF110), LROS (except BF110) 11 BGX 5000 Mechanical Interlock for BG Contactors All contactors are compliant with standards - IEC/EN 60947-1, IEC/EN 60947-4-1, UL508, CSA C22.2 n° 14. Add-on Blocks for BF Type Contactors BFX1011 BFX10 11 Screw Type Auxiliary Contact 1NO + 1NC (front centre mount) BFX10 02 Screw Type Auxiliary Contact 2NC (front centre mount) BFX10 20 Screw Type Auxiliary Contact 2NO (front centre mount) BFX10 22 Screw Type Auxiliary Contact 2NO + 2NC (front centre mount) BFX 5000 Mechanical Interlock for BF09 to BF38 Contactors 11 G2692 Mechanical Interlock for BF50 - BF110 Contactors Note - Four pole contactors and an extensive range of accessories can be found in our latest General Catalogue from www.Lovato.co.uk or contact our sales office for more information. Modular Contactors Order Code IEC Rated Current Ith in AC-1 (A) Two Pole 220-230V AC Contact Configuration N.O. N.C. CN20 11 220 20 CN20 20 220 20 25 CN25 01 220 CN40 10 220 1 1 Equipped with 2 or 4 closing contacts of equal capacity permitting use in power or auxiliary circuits -- 2 0 Operation flag indicator Fast mounting. 4.0 4 0 25 4.0 3 1 40 11.0 4 0 CN40 01 220 40 11.0 3 1 CN63 10 220 63 15.0 4 0 CN63 01 220 63 15.0 3 1 Auxiliary Contacts (one max per contactor) 1-5 DC powered magnetic core system assuring silent operation and noise damping during the control phase -- (For 24V AC/DC version change CN…….220 code to CN……...024) CN25 10 220 Operational Characteristics Overvoltage protection circuit and voltage peak limitation of the magnetic core (For 24V AC/DC version change CN…….220 code to CN……...024) Three or Four Pole 220-230V AC CN40…, CN20... Rated Motor Power IEC (kW) CNH 11 6 -- 1 1 CNH 20 6 -- 2 0 Noise level: Closed contactor ≤20dB Making/breaking operation ≤50dB IEC degree of protection: IP20 Mounting on 35mm DIN rail (IEC/EN 60175). Certifications and compliance Compliant with standards: IEC/EN 60947-1, 60947-4-1, 60947-5-1 and 61095 Enclosed Control Stations General Characteristics Order Code Description Operating temperature: -20...+55oC (RF9) Operating temperature: -25...+60oC (RF38) 1 Gang Plastic Enclosure Grey Cover S1P10 Standard Green PB "I" (START) c/w 1NO contact S1P01 Standard Red PB "O" (STOP) c/w 1NC contact S1P33 Double Touch PB "I/O" (START/STOP) c/w 1NO & 1NC contacts S1PK02 Key Switch 2 pos "I-O" c/w 1NO contact S1PK05 Key Switch 3 pos "I-O-II" c/w 2NO contact S1PSW7 Selector Switch 2 pos "I-O" c/w 1NO contact S1PSW9 Selector Switch 3 pos "I-O-II" c/w 2NO contact Storage temperature: -50...+70oC Degree of protection (Plastic): IP66, IP67, IP69K Degree of protection (Stainless): IP65 Base mounted contact blocks (plastic enclosures) Any combination of up to 6 gang stations available upon request and subject to availability Certifications and compliance Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 1 Gang Plastic Enclosure Yellow Cover S1P10 S1PY71 40mm Mushroom Twist Reset (STOP) c/w 1NC contact S1PY81 40mm Mushroom Key Reset (STOP) c/w 1NC contact S1PY91 40mm Mushroom Twist Reset (EMERGENCY STOP) c/w 1NC contact 2 Gang Plastic Enclosure Grey Cover S2P1001 S2P1071 S2P1091 Standard Green "I" PB's (START/STOP) c/w 1NO & 1NC contacts Standard Green "I" & 40mm Mushroom Twist Release PB's (START/STOP) c/w 1NO & 1NC contacts Standard Green "I" & 40mm Mushroom Twist Release EN418 PB's (START/EMERGENCY STOP) c/w 1NO & 1NC contacts 3 Gang Plastic Enclosure Grey Cover S1PY91 S3P101110 2x Standard Black "↑" & 1x Standard Red "O" PB's (FWD/STOP/REV) S3P107110 2x Standard Black "↑" & 1x 40mm Mushroom Twist Release PB's S3P109110 2x Standard Black "↑" & 1x 40mm Mushroom Twist Release EN418 1 Gang Stainless Steel Enclosure S2P1001 S1S10 S1S10 Standard Green PB "I" (START) c/w 1NO contact S1S01 Standard Red PB "O" (STOP) c/w 1NC contact S1S33 Double Touch PB "I/O" (START/STOP) c/w 1NO & 1NC contacts S1SK02 Key Switch 2 pos "I-O" c/w 1NO contact S1SK05 Key Switch 3 pos "I-O-II" c/w 2NO contact S1SW7 Selector Switch 2 pos "I-O" c/w 1NO contact S1SSW9 Selector Switch 3 pos "I-O-II" c/w 2NO contact S1S71 40mm Mushroom Twist Reset (STOP) c/w 1NC contact S1S81 40mm Mushroom Key Reset (STOP) c/w 1NC contact S1S91 40mm Mushroom Twist Reset (EMERGENCY STOP) c/w 1NC contact 2 Gang Stainless Steel Enclosure S2S1001 Standard Green "I" PB's (START/STOP) c/w 1NO & 1NC contacts S2S1071 Standard Green "I" & 40mm Mushroom Twist Release PB's S2S1091 Standard Green "I" & 40mm Mushroom Twist Release EN418 PB's S1S91 1-6 Enclosed Switch Disconnectors GAZ….. Order Code IEC Conventional Free Air Thermal Current Ith AC21A (≤690V) (A) Dimensions HxWxD (mm) 3 Pole Switch Disconnector with Red/Yellow Handle in Polycarbonate Enclosure GAZ016 16 GAZ025 25 GAZ032 32 GAZ040 40 GAZ063* 63 GAZ080* 80 GAZ100* 100 GAZ125* 125 Operational Characteristics Operating temperature: -25...+60oC Storage temperature: -40...+70oC Chemical resistant polycarbonate (GAZ... or stainless steel enclosure (GAZS…) Degree of protection: IP65 159 x 100 x 97 Padlockable handle Add fourth pole GAX42…… for four pole version 280 x 220 x 170 Cable entries: GAZ016 - GAZ040: 4 x M20 / M25 dual knockouts GAZ063 - GAZ125 and GAZS016 - GAZS125 smooth walls to be drilled by installer Cable capacities GAZ(S)016 - GAZ(S)040 = 16mm2 GAZ(S)063 - GAZ(S)125 = 50mm2 *GAZ063-GAZ125 supplied without earth terminals Certifications and compliance - Starters 3 Pole Switch Disconnector with Red/Yellow Handle in Satin Stainless Steel Enclosure GAZS…. GAZS016 16 GAZS025 25 GAZS032 32 GAZS040 40 GAZS063 63 GAZS080 80 GAZS100 100 GAZS125 125 Compliant with standards: IEC/EN 60947-3 and IEC/EN 60947-1 170 x 100 x 100 285 x 185 x 130 Switched Fourth Pole Add-On GAX42…. GAX42040A 16 - 40 GAX42063A 63 Fits GAZ(S)016 - GAZ(S)040 Fits GAZ(S)063 GAX42080A 80 Fits GAZ(S)080 GAX42100A 100 Fits GAZ(S)100 GAX42125A 125 Fits GAZ(S)125 Add-On Blocks GAX1011A 1NO+1NC Auxiliary contact block fits all types GAX31A Neutral Terminal for GAZ(S)016 - GAZ(S)040 Types GAX32A Neutral Terminal for GAZ(S)063 - GAZ(S)125 Types GAX33A Earth Terminal for GAZ(S)016 - GAZ(S)040 Types GAX34A Earth Terminal for GAZ(S)063 - GAZ(S)125 Types GAX1011A…. DC Switch Disconnectors For Solar Applications Order Code Current Rating Ith (A) Dimensions HxWxD (mm) 40 GAZ080DT4B 80 GAZ125DT4B 125 159 x 100 x 97 280 x 220 x 170 GAZ040DT4B 1-7 Storage temperature: -40...+70oC Degree of protection: IP65 Padlockable handle IEC Rated insulation voltage Ui: 1000VDC Rated operational current Ie DC21B for devices at operational voltages: Operating Voltage Insulated polycarbonate enclosure Operating temperature: -25...+60oC Switch Disconnector for DC Switching and Solar Applications GAZ040DT4B Operational Characteristics Certifications and compliance - Starters GAZ040DT4B GAZ080DT4B GAZ125DT4B Up to 48VDC 40A 80A 125A Up to 110VDC 35A 70A 120A Up to 400VDC 35A 40A 64A Up to 500VDC 32A 40A 56A Up to 600VDC 20A 30A 40A Up to 700VDC 15A 18A 20A Up to 800VDC 15A 18A 20A Compliant with standards: IEC/EN 60715 Enclosed Switchfuse Isolators Order Code Current Rating Ith (A) Dimensions HxWxD (mm) IP65 Switchfuse Isolator supplied with 10x38mm gG Fuses GAZ020F 20 GAZ032F 32 Operational Characteristics Insulated polycarbonate enclosure: IP65 Operating temperature: -25...+60oC Storage temperature: -40...+70oC 234 x 110 x 97 Includes switched fourth pole & padlockable handle For use with 10x38 gG fuse types Cable entries: 4 x M20 / M25 dual knockouts Certifications and compliance Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-3 GAZ….F Steel Enclosed Switch Disconnectors, Switchfuses, Changeover Switches IEC Conventional Free Dimensions inc Handle Air Thermal Current Ith HxWxD AC23A (≤690V) (mm) (A) 3 Pole Switch Disconnector with Red/Yellow Handle in Steel Enclosure with fitted neutral disconnect link Order Code GEZ0063 63 GEZ0100 100 GEZ0160 160 GEZ0250 250 GEZ0400 400 GEZ0630 630 300 x 300 x 246 GEZ…. GEZ….N 63 GEZ0100N 100 GEZ0160N 160 GEZ0250N 250 GEZ0400N 400 GEZ0630N 630 Operating temperature: -25...+60oC Storage temperature: -40...+70oC Ratings up to 630A Pressed steel enclosure: IP65 in RAL7035 Padlockable handles Generous wiring space 400 x 300 x 246 500 x 400 x 295 700 x 500 x 310 3 Pole Fuse Switch with Red/Yellow handle in steel enclosure with fitted neutral link and fuses GEZ0063N Operational Characteristics 500 x 400 x 245 500 x 400 x 295 800 x 600 x 310 Supplied with al cable shrouds Earth link to door fitted Disconnectable neutral link with shroud* Supplied with NH Fuses (NFC for 63A-100A)** Standard replaceable components Gland plate fitted to bottom Certifications and compliance Compliant with standards: IEC/EN 60947-3 and IEC/EN 60947-1 * Not fitted to changeover switches ** Fused switches only 1000 x 600 x 360 4 Pole Changeover Switches with Black handle in steel enclosure GEZ0063ET4 63 GEZ0100ET4 100 GEZ0160ET4 160 400 x 300 x 260 GEZ0250ET4 250 500 x 400 x 260 GEZ0400ET4 400 500 x 400 x 310 GEZ0630ET4 630 700 x 500 x 310 300 x 300 x 235 GEZ….E Neutral Link Standard Lovato Switches & Fuse Switches Fully Shrouded Door Earth Link Gland Plate 1-8 Enclosed Changeover Switches GX….P Rotary Cam Switches ON/OFF Current Rating AC1 (A) Order Code Dimensions HxWxD (mm) 3 Pole Changeover Switch with Black Handle in Polycarbonate Enclosure—centre off GX16 53 P 16 90 x 90 GX20 53 P 20 90 x 90 GX32 53 P 32 110 x 110 GX40 53 P 40 110 x 110 Insulated plastic enclosure Operating temperature: -25...+55oC Storage temperature: -40...+70oC Degree of protection: IP65 Top and bottom cable entry: 4 PG16 threaded knockouts for 90 x 90mm types and PG21 for 110 x 100mm types. Certifications and compliance 4 Pole Changeover Switch with Black Handle in Polycarbonate Enclosure—centre off Certifications obtained: GOST GX16 75 P 16 GX20 75 P 20 90 x 90 Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3 , IEC/EN 60947-5-1, IEC/EN 61058-1 GX32 75 P 32 110 x 110 GX40 75 P 40 110 x 110 Order Code Current Rating AC1 (A) Front Plate Size (mm) 90 x 90 Operational Characteristics Operating temperature: -25...+55oC Storage temperature: -40...+70oC Front Mount - One pole - 1 Wafer - ON/OFF Switches GX16 90 U 16 48 GX20 90 U 20 48 GX32 90 U 32 65 GX40 90 U 40 65 IEC 16 to 40A conventional free air thermal current Ith ratings IEC IP65 front degree of protection; IEC IP20 protection of contacts Rotation angles: 30° , 45° , 60° and 90° Certifications and compliance Front Mount - Two pole - 1 Wafer - ON/OFF Switches GX….U Operational Characteristics GX16 91 U 16 48 GX20 91 U 20 48 GX32 91 U 32 65 GX40 91 U 40 65 Certifications obtained: GOST; UL Listed for USA and Canada (File E155982) as Manual Motor Controllers Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-3 , IEC/EN 60947-5-1, IEC/EN 61058-1, UL508, CSA C22.2 n° 14 Example of U Version Switch Mounting Front Mount - Three pole - 2 Wafers - ON/OFF Switches GX16 10 U 16 48 GX20 10 U 20 48 GX32 10 U 32 65 GX40 10 U 40 65 Note - Our extensive range of rotary cam switches can be found in our General Catalogue available on request from our sales office Empty Enclosures M0N Suitable for LOVATO Contactor Type (to be ordered separately) Suitable for LOVATO Thermal Relay Type (to be ordered separately) Dimensions H x W x D (mm) M0N BG06 BG09 BG12 RF9 184 x 88 x 119.5 M1N BF09A BF12A BF18A RF38 202 x 88 x 134.5 M2N BF25A BF26A BF32A RF38 234 x 110 x 148.5 Order Code M24N (inc mount plate) All Above M25N (inc mount plate) All Above + BF38 M3N M3N BF38A BF50, BF65 BF80, BF95 BF110 Operational Characteristics 1-9 — Operating temperature: -25...+60oC Storage temperature: -40...+70oC Degree of protection: IP65 M0N, M1N and M2N have moulded din rail mount in base of enclosure and have external fixings to maintain IP rating M3N has a hinged lid and requires mounting plate MX30 for fitting of devices Certifications and compliance Compliant with standards: IEC/EN 60947-1 and IEC/EN 60947-4-1 210 x 175 x 98.5 RF38 RF953 * 210 x 175 x 158.5 280 x 220 x 170 Metal Mounting Plate for M3N Enclosure MX30 Insulated polycarbonate enclosure — 185W x 240H mm * For thermal overload relay (RF952) to use with BF38A contactor, please contact our customer services. Limit Switches Order Code Description Limit Switch body dimensions to EN50047 — order operating head separately below KXCBS11 KXCMS11 KXCCS11 KXCNS11 KXCBS11 Plastic body, one bottom M20 cable entry, 1NO+1NC snap action KXCMS11 Metal body, one bottom M20 cable entry, 1NO+1NC snap action KXCCS11 Plastic body, two side M20 cable entry, 1NO+1NC snap action KXCNS11 Metal body, two side M20 cable entry, 1NO+1NC snap action Operating Heads to Fit KX… Limit Switch Bodies KXA1 KXB... KXC... KXD... KXE... General Characteristics The KX C... bodies, complete with auxiliary contacts, can be coupled with the KX A... operating heads, to obtain complete limit switches in the required configurations. The body cover is hinged at the bottom and removable to have the best access. Each body includes the innovative locking bayonet mechanism of the operating head. Plastic and metal types are available. The heads are made of metal and warrant sturdiness and operating reliability in all conditions. The shape of the coupling section with the body of the K series switches permits to orient the head in any 45° angle position while the initial lever and rod position can be adjusted 360° at 15° angle positions. The head fixing to the body is achieved by the innovative locking bayonet mechanism so there is no need of tools. KXA A1 Top push rod plunger KXA B1 Plastic top roller push plunger KXA B2 Metal top roller push plunger KXA C1 Plastic roller centre push lever IEC thermal current Ith: 10A KXA C2 Metal roller centre push lever KXA D1 Plastic roller side push lever KXA D2 Metal roller side push lever IEC rated insulation voltage Ui: 690VAC for KX CB-KX CC types 440VAC for KX CM-KX CN types KXA E1 Plastic roller lever plunger KX CB-KX CC types Self-extinguishing double-insulation polymer thermoplastic KXA E2 Metal roller lever plunger KX CM-KX CN types - Aluminium-zinc alloy KXA E3 Rubber Ø50x10mm roller lever plunger Cable entry: M20 standard supplied KXA F1 Adjustable plastic roller lever Ø19x5mm Operating head fixing: Locking bayonet insert KXA F2 Adjustable metal roller lever Ø19x5mm Cable connection: Self-releasing screw terminal KXA F3 Adjustable rubber Ø50x10mm roller lever KXA F4 Adjustable offset rubber Ø50x10mm roller lever KXA H1 Ceramic rod lever KXA L1 Adjustable plastic rod lever KXA L2 Adjustable stainless steel rod lever KXA M1 Flexible wobble stick KXA M2 Semi-rigid wobble stick Operational characteristics Mechanical life: >10 million cycles Conductor section: 1 or 2 2.5mm2 max / 16-14 AWG • Operating temperature: -25 ... +70°C • Storage temperature: -40 ... +70°C • IEC degree of protection: IP65 for body housing. Certifications and compliance Certifications obtained: EAC for all, UL Listed for US and Canada (File E93601), as Auxiliary Devices for KX C... body types only. UL Recognized for USA and Canada (cURus - File E93601) as component Comply with standards: EN50047, IEC/EN 60947-1, KXE3 See General Catalogue for the full range of limit, micro and foot switches or online at www.lovato.co.uk KXF... KXF4 Foot Switches KXH1 KXL... Order Code KXM1 KXM2 Description Plastic Body Foot Switch M20 Cable Entry KG100S11 KG100 S11 Open foot switch with 1NO+1NC action contacts KG200 S11 Foot switch with 1NO+1NC action contacts—with cover KG110 S11 Open foot switch with 1NO+1NC action contacts c/w safety lever KG210 S11 Foot switch with 1NO+1NC action contact c/w cover and safety lever KG120 S11 Open foot switch with 1NO+1NC action contacts c/w actuator lock KG220 S11 Foot switch with 1NO+1NC action contacts c/w cover and actuator lock Metal Body Foot Switch M20 Cable Entry KG210S11 Thermoplastic or metal version Versions complete with or without pedal protection cover The cover assures protection against accidental operation, due to sudden tool or heavy material dropping on switch. Versions with safety lever; The safety mechanism prevents unintentional foot switch activation and excludes the pedal pressing if the operator’s foot is not completely in place. KR100 S11 Open foot switch with 1NO+1NC action contacts KR200 S11 Foot switch with 1NO+1NC action contacts—with cover KR110 S11 Open foot switch with 1NO+1NC action contacts c/w safety lever KR210 S11 Foot switch with 1NO+1NC action contact c/w cover and safety lever Mechanical life: >10 million cycles KR120 S11 Open foot switch with 1NO+1NC action contacts c/w actuator lock Conventional thermal current Ith: 10A KR220 S11 Foot switch with 1NO+1NC action contacts c/w cover and actuator lock See General Catalogue for the full range of foot switches or online at www.lovato.co.uk KR210S11 General characteristics The KG and KR foot switches are used to control machinery and other equipment, leaving the operator’s hands free to do other functions. Operational characteristics Designation to IEC/EN 60947-5-1: Class II insulation (KG types only) Operating temperature: -25 ... +70°C 1-10 Signal Towers and Beacons Order Code Description Signal Tower Kits—Steady Light—do not include bulbs, see bottom of page LT7KIT-R RED Lens 8LT7EL4 steady light module with BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-G GREEN Lens 8LT7EL3 steady light module with BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-RG RED+GREEN Lens 8LT7EL... steady light modules, BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-RYG RED+YELLOW+GREEN Lens 8LT7EL... steady light modules, BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-RYGB RED+YELLOW+GREEN+BLUE Lens 8LT7EL... steady light modules, BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-RYGBW RED+YELLOW+BLUE+GREEN+WHITE Lens 8LT7EL... steady light modules, BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base with 100mm extension. LT7KIT-G General Characteristics - Signal Towers Signal towers are fundamental elements in manufacturing processes for the visual and audible signalling of the system status. The signal towers can be assembled by stacking up to 7 modules, in the following sequence, starting from the top: red, yellow, orange, blue, green and white. The sound module, if any, must always be positioned at the top of the signal tower. Technical characteristics Maximum operational voltage: 250VAC/DC Material: Polycarbonate or anodised aluminium Connections: Screw clamp terminals, maximum 1.5mm2/16 AWG conductor section Tightening torque: 0.5Nm/4.5lbin Operating temperature: -20...+50°C Number of stackable elements: Seven. Degree of protection IEC/EN: IP65; IP54 for 8 LT7 S0B . Certifications and compliance Certifications obtained: EAC, UL Listed, for USA and Canada (cULus file E318016) as Power Circuit and motor-mounted Apparatus - Stackable tower lights. Compliant with standards: IEC/EN 60947-5-1, IEC/EN 60947-1, UL508, CSA C22.2 n° 14. Additional Flashing Modules—include xenon bulbs 8LT7FLB3 Green flashing module 24VAC/DC 8LT7FLB4 Red flashing module 24VAC/DC 8LT7FLB5 Yellow flashing module 24VAC/DC 8LT7FLM3 Green flashing module 230VAC 8LT7FLM4 Red flashing module 230VAC 8LT7FLM5 Yellow flashing module 230VAC Signal Tower Sounder Modules LT7KIT-RYGB 8LT7S0B 24VAC/DC Pulsed 90dB 8LT7S2B 24VAC/DC Pulsed or Continuous 75dB 8LT7S2M 230VAC Pulsed or Continuous 75dB Stand Alone Beacons LB6KIT-O LB6KIT-G LB6KIT-R LB6KIT-Y LB6KIT-B LB6KIT-W LB6KIT-G 8LT7ALL... 1-11 ORANGE Lens 8LB6EL1 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. GREEN Lens 8LB6EL3 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. RED Lens 8LB6EL4 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. YELLOW Lens 8LB6EL5 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. BLUE Lens 8LB6EL5 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. WHITE Lens 8LB6EL8 steady light module with BA15d lamp fitting, direct supply with8LB6BP03 surface mount base. Bulbs for Signal Tower and Beacons General characteristics—Beacons Signal beacons are fundamental elements in manufacturing processes for the visual and audible signalling of the system status. Technical characteristics Maximum operational voltage: 250VAC/DC 8LT7ALB B 24VAC/DC 5W BA15d Incandescent bulb Material: Polycarbonate 8LT7ALB M 230VAC 5W BA15d Incandescent bulb Connections: Screw clamp terminals, maximum 1.5mm2/16 AWG conductor section 8LT7ALL B8 24VAC/DC LED BA15d bulb Tightening torque: 0.5Nm/4.5lbin 8LT7ALL M8 230VAC LED BA15d bulb Please note: We have many other options for signal towers and beacons in our General Catalogue or online at www.lovato.co.uk Operating temperature: -20...+50°C Degree of protection IEC/EN: IP54; IP30 if used with 8 LB6 BP 04, 8 LB6 BP 06 or 8 LB6 BP 08. Certifications and compliance Compliant with standards: IEC/EN 60947-5-1, IEC/EN 60947-1. Switching Power Supplies Order Code Rated Output Voltage (V) Output Power (W) Single Phase General Characteristics This type of equipment is used to power supply electromechanical and electronic devices with DC control, such as contactors, time relays, sensors, PLCs, DC motors, displays, SSRs and other equipment normally found in automation systems and networks. PSL1 005 24 0.21 5 Protections: PSL1 010 24 0.42 10 PSL1 018 24 0.75 18 Short circuit, Overload, Input voltage peaks Indications: PSL1 030 24 1.25 30 PSL1 060 24 2.5 60 4.2 100 5 120 PSL1 240 24 10 240 PSL1 300 24 12.5 300 PSL1 480 24 20 480 4.2 100 PSL1 100 24 24VDC PSL1 120 24 PSL1 030 24 PSL 1 060 24 Rated Output Current (A) Two Phase PSL2 100 24 PSL3 120 24 PSL3 480 24 LED indicator for power on Operational Characteristics Rated supply voltage: 100-240VAC for PSL1 005 24 - PSL1 100 24 types 115/230VAC self-configurable for PSL1 120 24… to PSL1 480 24 types 400-500VAC for PSL2... and PSL3... ❶ types Rated output voltage: 24VDC Mains frequency: 50/60Hz Output voltage adjustment by front potentiometer 24VDC 24VDC PSL3 960 24 PFC function for types: PSL1 120 24 to PSL3 960 24 5 120 ❶ Parallel connection for types: PSL1 120 24, PSL1 240 24, PSL1 300 24, PSL1 480 24, PSL2 100 24, PSL3 240 24, PSL3 480 24, PSL3 960 24 10 240 ❶ High efficiency up to 92% 20 480 ❶ 35mm DIN rail (IEC/EN 60715) mounting 40 960 ❶ Three Phase ❶ PSL3 240 24 LED indicator for low voltage conditions Screw connection terminals Plastic or metal housing depending on type ❶ Two-phase connection is admissable with a 25% output power derating. IEC degree of protection: IP20 on terminals PSL1 100 24 PSL1 120 24 Modular Switching Power Supplies Rated Output Current (A) Output Power PSL1M 010 12 0.83 10 PSL1M 024 12 2 24 2.75 33 PSL1M 054 12 4.5 54 PSL1M 072 12 6 72 PSL1M 010 24 0.42 10 PSL1M 024 24 1 24 1.5 36 PSL1M 060 24 2.5 60 PSL1M 100 24 4.2 100 Order Code Rated Output Voltage (V) (W) Single Phase PSL1M 033 12 12VDC General Characteristics Protections: Short circuit, Overload, Input voltage peaks Indications: LED indicator for low voltage conditions LED indicator for power on Operational characteristics Rated supply voltage: 100-240VAC Rated output voltage: 12VDC for PSL1M...12 types; 24VDC for PSL1M...24 types Mains frequency: 50/60Hz PSL1M 036 24 PSL1M 010…. 24VDC Output voltage adjustment by front potentiometer High efficiency up to 89% 35mm DIN rail (IEC/EN 60715) mounting Screw connection terminals Modular DIN 43880 housing; number of modules: 1 for PSL1M 010… 2 for PSL1M 024… 3 for PSL1M 033 12 and PSL1M 036 24 4 for PSL1M 054 12 and PSL1M 060 24 5 for PSL1M 072 12 and PSL1M 100 24 IEC degree of protection: IP20 on terminals Certifications and compliance Certifications obtained: GOST, UL Listed for USA and Canada (File E318016) as Power Supplies in power circuit and motor-mounted apparatus category. Compliant with standards: IEC/EN 60950-1, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL508, CSA C22.2 n° 14 PSL1M 033 12 PSL1M 036 24 1-12 Feed-Through Terminal Blocks CBD Series CBD.2 Order Code Rated Cable Size Current Rating Terminal Pitch (mm) (A) (mm) Feed-Through Terminal Blocks CBD.2 2.5 24 5.5 120 CBD.4 CBD.6 CBD.10 CBD.16 CBD.35 CBD.50 32 41 57 76 101 125 6.5 8 10 12 16 18 100 100 100 50 75 50 CBD.70 70 192 Ex(i) Blue Feed-Through Terminal Blocks CBD.2EXI 2.5 24 CBD.4EXI 4 32 CBD.6EXI 6 41 CBD.10EXI 10 57 20.5 40 5.5 6.5 8 10 120 100 100 100 CBD.16EXI 16 76 12 CBD.35EXI 35 101 16 CBD.50EXI 50 125 18 CBD.70EXI 70 192 20.5 ‘Big Box’ Bulk Packed Feed-Through Terminal Blocks BB/CBD.2 2.5 24 5.5 BB/CBD.4 4 32 6.5 BB/CBD.6 6 41 8 BB/CBD.10 10 57 10 50 75 50 40 Order Code 4 6 10 16 35 50 To Suit Feed-Through Terminal Type To Suit Terminal Type Suitable for both 35mm ‘Top Hat’ and 32mm ‘G’ section rail mounting Superior effective current carrying capacity, Very low contact resistance of the resulting connection Ex (i) versions for use in ‘intrinsic safety’ circuits Technical Characteristics UL94V-0 polyamide insulating body Available in standard beige (RAL 1001) Operating temperature range: -40 ÷ +80 °C Certifications and compliance UL CSA KEMA - KEUR BBJ-SEP RINA 1400 1000 900 600 IEEE 323 (1E Qualification for Nuclear Power Plants) Lloyds Register of Shipping ENEL LV27/1 Pack Quantity 50 25 25 25 25 10 CB.70/PT CBD.70 CBR/PT CBR.2 End Sections for Ex(i) Blue Feed-Through Terminals CB.2/PTEXI CBD.2 CB.6/PTEXI CBD.4 & CBD.6 CB.10/PTEXI CBD.10 CB.16/PTEXI CBD.16 CB.35/PTEXI CBD.35 CB.50/PTEXI CBD.50 CB.70/PTEXI CBD.70 Order Code General Characteristics CBD Series terminal blocks, within Cabur polyamide production, are the basic series having feed-through function. Reduced overall dimension End Sections for Feed-Through Terminal Blocks CB.2/PT CBD.2 CB.6/PT CBD.4 & CBD.6 CB.10/PT CBD.10 CB.16/PT CBD.16 CB.35/PT CBD.35 CB.50/PT CBD.50 CBD.35 Pack Quantity 10 25 50 25 25 25 25 10 10 No of Ways Pack Qty Pre-assembled Cross-connections PM Pre-assembled Cross-connection 2-1 PM/20/2 CBD.2, TLD.2/GR 2 25 PM/20/3 CBD.2 3 25 PM/20/5 CBD.2 5 25 PM/20/10 CBD.2 10 10 PM/40/2 CBD.4, 2 25 PM/40/3 CBD.4 3 25 PM/40/5 CBD.4 5 25 PM/40/10 CBD.4 10 10 PM/60/2 CBD.6 2 25 PM/60/3 CBD.6 3 25 PM/60/5 CBD.6 5 25 PM/60/10 CBD.6 10 10 PM/41/2 DAS.4 2 25 PM/51/3 DAS.4 3 25 PM/51/5 PM/51/10 DAS.4 DAS.4 5 10 25 10 For the full range available visit: www.cabur.eu CBD Series Assembly Feed-Through Terminal Blocks CBC Series Order Code Rated Cable Size Current Rating Terminal Pitch (mm) (A) (mm) Pack Quantity CBC Series Feed-Through Terminal Blocks 2.5 24 5 120 CBC.4/GR 4 32 6 100 Patented ‘Easy-bridge’ cross-connection system CBC.6/GR 6 41 8 100 Superior effective current carrying capacity CBC.10/GR 10 57 10 100 Very low contact resistance of the resulting connection CBC.16/GR 16 101* 12 50 Ex (i) versions for use in ‘intrinsic safety’ applications CBC.35/GR 35 150** 16 50 Suitable for 35mm ‘Top Hat’ rail mounting only Technical Characteristics CBC.2 (Ex)i 2.5 24 5 120 CBC.4(Ex)i 4 32 6 100 UL94V-0 polyamide insulating body CBC.6( Ex)i 6 41 8 100 1000V Rated to IEC 60947-7-1 CBC.10 (Ex)i 10 57 10 100 Available in standard grey (RAL 7042) or blue (Ex versions) CBC.16 (Ex)i 16 101* 12 50 CBC.35 (Ex)i 35 150** 16 50 Certifications and compliance CBC Series ‘Big Box’ Bulk-Packed Feed-Through Terminal Blocks cURus BB/CBC.2/GR 2.5 24 5 1400 KEMA - KEUR BB/CBC.4/GR 4 32 6 1000 RINA *101A when using 25sq mm conductor **150A when using 50sq mm conductor Order Code UL(BR) TERNA LV27/1 To Suit Feed-through Terminal Type Pack Quantity End Sections for CBC Series Feed-Through Terminal Blocks CBC.2-10/PT/GR CBC.2/GR-CBC.10/GR 50 CBC.16/PT/GR CBC.16/GR 25 CBC.35/PT/GR CBC.35/GR 25 CBC.2 (Ex)i-CBC.10 (Ex)i 50 CBC.16/PT (Ex)i CBC.16 (Ex)i 25 CBC.35/PT (Ex)i CBC.35 (Ex)i 25 CBC.2-10/PT (Ex)i Accessories for Feed-Through Terminal Blocks CBC Series Reduced overall dimension CBC.2/GR CBC Series Ex(i) Blue Feed-Through Terminal Blocks CBC.2/GR General Characteristics CBC Series terminal blocks, with UL94V-0 polyamide insulating body, feature enhanced design accuracy. Terminal blocks with different cross -sections still guarantee visual uniformity within the completed rail assembly. To Suit No of Current Pack Terminal Poles Rating (A) Quantity ‘Easy Bridge’ Permanent Cross-connections for CBC Series Order Code PTC/2/10 CBC.2 10 24 10 PTC/4/10 CBC.4 10 32 10 PTC/6/10 CBC.6 10 41 10 PTC/10/10 CBC.10 10 57 10 POF/53 CBC.16 2 76 25 POF/06 CBC.35 2 125 15 ENEL DV27/1 ATEX Ex (e) & IEC (Ex) pending General Characteristics Patented ‘Easy-bridge’ cross-connection in 2, 3, 5, 10 or 50 pole versions. Screwless, snap-in insertion with transversal and staggered mode connection possibility. Once inserted, the resulting installation is IPXXB protected without the need for further insulating covers. Coloured Partition—Red DFU/4/ROSSO CBC.2/GR-CBC.35/GR 50 FOR END BRACKETS & TERMINAL MARKING SYSTEMS PLEASE SEE PAGES 2-8 TO 2-10 EasyBridge Cross-connection For the full range available visit: www.cabur.eu 2-2 Special Version Terminal Blocks Order Code Rated Cable Size Description Pack Qty Feed-through on 2 or 3 levels (mm) Suitable for 35mm ‘Top Hat’ rail mounting Two & Three Level Terminal Blocks DBC.2/GR 2 Level Feed-Through - Grey 35mm ‘Top Hat’ mounting only DAS.4 TLD.2 2.5 120 2 Level Feed-Through 4 120 3 Level Feed-Through 2.5 125 4 70 Fused Terminal Blocks DBC.2/GR SFR.4 Link Blade 5x20mm 6.3A Max Order Code Pack Qty To Suit Terminal Type End Sections for Special Version Terminal Blocks DBC/PT/GR Grey for DBC.2/GR 25 DAS.4 25 Grey for TLD.2/GR 25 SFR.4 25 DAS/PT TLD/PT/GR SFR/PT General Characteristics - Two & Three-Level Terminal Blocks Two & three level terminal blocks, with Cabur polyamide insulating body SFR.4/GR Version for proximity sensors Technical Characteristics UL94V-0 polyamide insulating body Available in standard beige RAL 1001 (or grey RAL 7042 where indicated) Certifications and compliance cURus / KEMA-KEUR / RINA/ Lloyds Register General Characteristics - Fused Terminal Blocks Fuseholder terminals, with Cabur polyamide insulating body Available for 5x20mm or 6x32mm fuses Suitable for both 35mm ‘Top Hat’ or 32mm ‘G’ rail mounting Technical Characteristics UL94V-0 polyamide insulating body Available in standard beige RAL 1001 (or grey RAL 7042 where indicated) Certifications and compliance cURus / KEMA-KEUR / RINA / Lloyds Register Earth Terminal Blocks Order Code Rated Cable Size Description Pack Qty Versions suitable for either 35mm ‘Top Hat’ or 32mm ‘G’ rail mounting (mm) Earth Terminal Blocks TEO.2 Earth for 35mm ‘Top Hat’ Rail 2.5 75 TEO.4 Earth for 35mm ‘Top Hat’ Rail 4 50 UL94V-0 polyamide insulating body TE.6/O Earth for 35mm ‘Top Hat’ Rail 6 45 Operating temperature range: -40 ÷ +80 °C TE.10/O Earth for 35mm ‘Top Hat’ Rail 10 35 TE.16/O Earth for 35mm ‘Top Hat’ Rail 16 30 TE.50/O Earth for 35mm ‘Top Hat’ Rail 50 15 To Suit Earth Terminal Type Pack Qty End Sections for Earth Terminal Blocks High Current Terminal Blocks Technical Characteristics TEO.2 Order Code TE.16/O General Characteristics Earth terminal blocks, with Cabur polyamide green/yellow insulating body cURus KEMA-KEUR RINA ENEL LV27/7 CESI 02ATEX 061 U EEx e certificate TEO.2/PT TEO.2 50 TEO.4/PT TEO.4 50 Order Code Certifications and compliance Rated Cable and Lug Size (mm) Current Rating (A) Pack Qty General Characteristics Power terminal blocks, with Cabur polyamide insulating body Possibility to perform cross connections GPM Series Insulated Studded Bar Power Feed Through Terminal Blocks GPM.95/BB 95/M8 232 10 GPM.150/BB 150/M10 309 6 GPM.240/BB 240/M12 415 4 Suitable for both 35mm ‘Top Hat’ and 32mm ‘G’ rail mounting Technical Characteristics UL94V-0 polyamide insulating body Operating temperature range: -40 ÷ +80 °C Certifications and compliance cULus pending / KEMA-KEUR / RINA GPM.150/BB Distribution Terminals General Characteristics - Multi-pole Neutral/Earth Terminals Order Code No. of Poles Terminal Size Colour Multi-pole Neutral / Earth Terminals QBLOK.7/BLU 7 10mm Blue QBLOK.7/TE 7 10mm Green QBLOK.12/BLU 12 10mm Blue QBLOK.12/TE 12 10mm Green QBLOK.7/BLU 2-3 For the full range available visit: www.cabur.eu Multipole Neutral or Earth terminals with 35mm Top Hat Mounting PA6 Insulating body Marking Systems for Terminal Blocks Order Code Marking & No. of Series Tags/ Card Universal Marking Tags CNU/8/51 Blank 1x100 Blank Tag Marker Pen (Black) 1 CNU/8/510 Series 1-10 (10 tags of each no) 5x100 CNU/8/520 Series 11-20 (10 tags of each no) 5x100 CNU/8/530 Series 21-30 (10 tags of each no) 5x100 CNU/8/540 Series 31-40 (10 tags of each no) 5x100 CNU/8/550 Series 41-50 (10 tags of each no) 5x100 CNU/8/560 Series 51-60 (10 tags of each no) 5x100 CNU/8/570 Series 61-70 (10 tags of each no) 5x100 CNU/8/580 Series 71-80 (10 tags of each no) 5x100 CNU/8/590 Series 81-90 (10 tags of each no) 5x100 CNU/8/600 Series 91-100 (10 tags of each no) 5x100 CNU/8/L1 L1 (Full card of symbol) 5x100 CNU/8/L2 L2 (Full card of symbol) 5x100 CNU/8/L3 L3 (Full card of symbol) 5x100 CNU/8/U1 U1 (Full card of symbol) 5x100 CNU/8/U2 U2 (Full card of symbol) 5x100 CNU/8/V1 V1 (Full card of symbol) 5x100 CNU/8/V2 V2 (Full card of symbol) 5x100 CNU/8/W1 W1 (Full card of symbol) 5x100 CNU/8/W2 W2 (Full card of symbol) 5x100 CNU/8/PE PE (Full card of symbol) 5x100 CB/CTL/NERO Also Available CNU/8/510 General Characteristics Universal Marking Tags ideal for marking all types of Cabur Railmounted Terminal Blocks. White polyamide with black printing 5mm standardised pitch and 8mm high To be applied directly into position before or after assembly of the terminal board Many other marking options available visit: www.cabur.eu End Stops, Protection Covers & Brackets Order Code Pack Qty Description End Stops BT/2 End stop for 15mm rail 25 BT/3 End stop for 35mm ‘Top Hat’ rail 25 BT/U Universal end stop for 32/35mm rail 25 Protection Covers BTU PZM.4 PZM.6 Cover 64mm wide to suit CBD terminal blocks up to 58mm depth inc din rail Cover 85mm wide to suit CBD terminal blocks over 58mm depth inc mounting rail 2m 2m Supports for Protection Covers PZD.4/SO Support for PZM.4 20 PZD.6/SO Support for PZM.6 10 Mounting Brackets for DIN Rail PZM Cover + PZD Supports ACI121213 Straight Mounting Bracket 20 ACI121314 Angled Mounting Bracket 20 General Characteristics - End Stops End stops for Cabur rail-mounted terminal blocks Available for 15mm ‘Top Hat’, 35mm ‘Top Hat’ and 32mm ‘G’ section rails BT/U Universal version suits both 35mm ‘Top Hat’ and 32mm ‘G’ section rails General Characteristics - Protection Covers Protection Covers for Cabur terminal blocks Protection against accidental contact or tampering PZM covers for terminals up to 70mm capacity PRP covers for safety protection of multiple crossconnections performed with PMP commoning bars General Characteristics DIN rail mounting brackets ‘CR6-Free’ RoHS Compliant Choice of straight or inclined mounting brackets to suit ACI121314 We have presented in this catalogue only a few of the faster moving items. For the full catalogue download and technical datasheets please visit www.cabur.eu using the product search facility. For the full range available visit: www.cabur.eu 2-4 Grey Standard Open Slot Trunking Order Code Dimensions Base Height (mm) (metres) Built-in wire retainer - double restricted slots on some sizes 17 120 Smooth fingers will not injure the installer or damage cables 30 96 Staggered mounting hole pattern for use in cabinets which are designed to these standards. CZE25* 40 72 CZE16 30 80 CZE13 40 60 60 40 CZE14 80 32 CZE34 100 24 CZE23 30 48 Self extinguishing rigid PVC Class 1 (UL94-VO) CZE8 40 40 Colour: Grey - RAL7030 60 36 CZE15 80 24 CZE35 100 16 CZE24 30 32 CZE4 40 24 60 24 CZE11 80 24 CZE18 100 16 CZE26 40 24 60 24 80 24 CZE36 100 16 CZE27 40 16 CZE17 60 20 80 16 CZE37 100 16 CZE43 150 8 CZE28 40 16 60 16 80 16 CZE38 100 8 CZE30 60 12 80 12 100 8 60 8 80 8 100 8 CZE22* CZE7 CZE5 CZE9 CZE6 CZE12 CZE19 Spare Trunking Lid Order Code To Suit Trunking Base Width (mm) CZE10 CZE32 CZGCOP25 25 CZGCOP40 40 CZE33 CZGCOP60 60 CZE39 CZGCOP80 80 CZE31 CZGCOP100 100 CZE48 CZGCOP150 150 CZE40 15 25 40 60 80 100 120 150 200 *Note: Trunking with 4mm slots 3-1 General Characteristics Wiring ducts with large fingers and larger slots for easy insertion of larger wires and cables. Lead free. (mm) CZE20* CZE Standard Slot Trunking Pack Qty Smooth wire entry allows for quick insertion of wires Double scoreline allows easy removal of wall section or individual fingers by hand without the use of tools Non-slip cover with exclusive cover design with maximum grip RoHS Certified - Lead Free Manufactured in 2m lengths Technical Characteristics Wire ducts with 8mm slots (4mm for CZE20, 22 & 25) Certifications and compliance A Norme EN50085-2-3 CSA UR RINA CE marked Trunking Lid Covers for Standard and Narrow Slot Trunking. Supplied in 2m lengths Colour: Grey - RAL7030 RoHS Certified - Lead Free Grey Narrow Open Slot Trunking Order Code Dimensions Pack Qty General Characteristics Designed for terminal block and Din component applications with higher number of entries into the duct. Lead free. Base Height (mm) (mm) (metres) Built-in wire retainer - double restricted slots on some sizes CZE164 30 80 Smooth fingers will not injure the installer or damage cables CZE134 40 60 Staggered mounting hole pattern for use in cabinets which are designed to these standards. 60 40 CZE144 80 32 CZE344 100 24 CZE84 40 40 CZE54 60 36 80 24 CZE354 100 16 Self extinguishing rigid PVC Class 1 (UL94-VO) CZE44 40 24 Colour: Grey - RAL7030 60 24 80 24 CZE184 100 16 CZE264 40 24 RINA To Suit Trunking Base Width (mm) CZE64 60 24 CE marked 80 24 CZGCOP25 25 CZE364 100 16 CZGCOP40 40 CZE174 60 20 CZGCOP60 60 CZE194 80 16 CZGCOP80 80 CZE374 100 16 CZGCOP100 100 CZE104 60 16 CZGCOP150 150 80 16 CZE74 CZE..4 Narrow Slot Trunking 25 40 CZE154 CZE94 60 CZE114 Spare Trunking Lid ‘EDGE’ Trunking 80 CZE124 100 120 CZE324 Order Code CZED110K60 Dimensions (mm) Pack Qty (metres) 110 x 110 x 60 8 Double scoreline allows easy removal of wall section or individual fingers by hand without the use of tools Non-slip cover with exclusive cover design with maximum grip RoHS Certified - Lead Free Manufactured in 2m lengths Technical Characteristics Wire ducts with 4mm slots Certifications and compliance A Norme EN50085-2-3 CSA UR Trunking Lid Covers for Standard and Narrow Slot Trunking. Supplied in 2m lengths Colour: Grey - RAL7030 RoHS Certified - Lead Free General Characteristics EDGE angular slotted trunking with 4mm slots for electrical panels . The Edge wire duct is designed to be used on the very corner of the enclosure where the space is normally not utilized. This system allows wires and cables to be routed professionally to the lateral panels. One single size, 110 X 110 mm with 60 mm opening Colour: Grey - RAL7030 Dimensions (mm) RoHS Certified - Lead Free Manufactured in 2m lengths 60 16 Certifications and compliance 60 A Norme EN50085-2-3 CSA UR CZED110K60 CE 110 Order Code Smooth wire entry allows for quick insertion of wires 110 3-2 Halogen Free Open Slot Trunking Order Code (mm) (mm) (metres) EHF2525 25 84 EHF2537 37.5 64 50 52 EHF2575 75 32 EHF3737 37.5 48 50 32 EHF3775 75 32 EHF5050 50 24 75 24 Temperature class 113 (-25degC to +105degC) 50 24 Available in standard grey colour RAL7035 75 16 50 16 75 16 75 12 EHF5075 EHF7550 EHF7575 EHF10050 EHF10075 EHF12575 25 37.5 50 75 100 125 Order Code Dimensions Rail Vehicles: Underground Trains, High Speed Trains etc Hostile environments such as: Nuclear reactors, Petrochemical plants, Offshore Oil Platforms Military applications such as: Aircraft, Armoured vehicles, Submarines, Ships Technical Characteristics UL94-VO NFF2 (old VDE 0472 prt 815) Manufactured in 2m lengths Approvals & Certification CE General Characteristics Available in grey colour RAL7030 Manufactured in 2m lengths Base Height (mm) (mm) (metres) 25 84 A Norme EN50085-2-3 37.5 64 CSA 50 52 ED2575 75 32 ED3737 37.5 48 50 32 75 32 50 24 75 24 50 24 75 16 50 16 75 16 75 12 ED2537 ED2550 ED3750 25 37.5 ED3775 ED5050 ED5075 ED7550 ED7575 ED10050 ED10075 ED12575 3-3 Pack Qty Public buildings with a high density of people such as: Hotels, Cinemas, Theatres, Supermarkets, Offices, Banks Self-extinguishing rigid PVC Class 1 (UL94-V0) ED2525 ED DIN Size Open Slot Trunking General Characteristics Alofree wiring ducts are safe products: free from halogen additives, they do not release toxic or corrosive gases and do not propagate flames as the surface carbonisation prevents the material from catching fire, even when in direct contact with the flames. They develop good resistance to chemical and marine substances and have high insulating power. All the corners in the open type trunking are rounded to prevent injury and to avoid cuts in the cable insulation. They are recommended for use in: Height EHF3750 DIN Size Open Slot Trunking Pack Qty Base EHF2550 EHF Halogen-free Open Slot Trunking Dimensions 50 75 100 125 Approvals & Certification CE Flexible Open Slot Ducting Order Code Dimensions Base x Height (mm) Pack Qty FLX10 12.5 x 12.5 25 FLX20 20 x 20 25 FLX30 30 x 30 25 FLX40 40 x 40 25 Description Pack Qty (metres) General Characteristics Self Adhesive flexible ducting Self-extinguishing UL94-V2 Nylon Temperature range -15degC to +80degC Supplied in 500mm lengths FLX - Flexible Open Slot Ducting Trunking Accessories Order Code Marking Accessory PTE Label Holder 50 Cross-arm retainer 25 Description Pack Qty General Characteristics PTE Label Holder for Labelling CZE/E4 Trunking PTR Cross Arm Accessory used to retain cables when trunking cover is removed. Adjustable along finger height to retain large or small wire bundles. Can be cut down to suit base width of trunking. Cross Arm Accessory PTE Label Holder Cutting Tools PTR Order Code General Characteristics ETC120 cuts precise lengths of trunking ETC120 will cut to a maximum size of 120 x 120mm Bench Cutting Tool ETC120* Bench cutting tool 1 ETC120L Spare blade for ETC120 1 Tool for punch-cutting sides of trunking 1 Hand Held Cutting Tool ECUT ETC120* Spiral Flexible Wrap *Note: Colour may vary from picture shown Order Code Dimensions Pack Qty Dia (mm) (metres) CP3 3 50 CP6 6 25 CP10 10 25 CP12 12 25 CP14 14 20 CPN3 3 50 CPN6 6 25 CPN10 10 25 CPN12 12 25 CPA3 3 50 CPA6 6 25 CPA10 10 25 CPA12 12 25 Normal/Transparent General Characteristics Spiral flexible ducting for wire bundles Manufactured in Polyethylene Normal/Black Self-extinguishing UL94-V2 CP Transparent Spiral Flexible Wrap 3-4 Open-type Panel Transformers TM Series Order Code Primary Secondary Dimensions Voltage (VAC) Voltage (VAC) HxWxD (mm) 30VA Rated TM030.240.024 220/240 24 75 x 75 x 65 50VA Rated TM050.240.024 TM050.240.110 220/240 220/240 24 110 TM050.415.024 TM050.415.110 TM050.415.240 100VA Rated 380/415 380/415 380/415 24 110 240 TM110.240.024 TM110.240.110 220/240 220/240 24 110 TM110.415.024 TM110.415.110 TM110.415.240 150VA Rated 380/415 380/415 380/415 24 110 240 TM115.240.024 TM115.240.110 TM115.415.024 TM115.415.110 TM115.415.240 220/240 220/240 380/415 380/415 380/415 24 110 24 110 240 220/240 220/240 380/415 380/415 380/415 24 110 24 110 240 220/240 24 220/240 380/415 380/415 380/415 110 24 110 240 220/240 220/240 380/415 380/415 380/415 24 110 24 110 240 120 x 122 x 115 220/240 220/240 380/415 380/415 380/415 24 110 24 110 240 120 x 122 x 135 200VA Rated TM120.240.024 TM120.240.110 TM120.415.024 TM120.415.110 TM120.415.240 300VA Rated TM130.240.024 TM130.240.110 TM130.415.024 TM130.415.110 TM130.415.240 400VA Rated TM140.240.024 TM140.240.110 TM140.415.024 TM140.415.110 TM140.415.240 500VA Rated TM150.240.024 TM150.240.110 TM150.415.024 TM150.415.110 TM150.415.240 750VA Rated TM175.240.024 TM175.240.110 TM175.415.110 TM175.415.240 General Characteristics Open-style single phase separation-type power transformers for electrical panels Simple wiring via large terminal block Double-wound centre-tapped construction Low loss laminations Earth connection on frame Available in sizes 30VA upto 2kVA 82 x 85 x 75 Technical Characteristics Thermal insulation Class B Insulation Voltage Primary/Secondary 3.5kV Max Ambient Temp 40oC Frequency 50/60Hz 82 x 85 x 95 Electrical protection Class I Weights 105 x 100 x 95 105 x 100 x 105 30VA 1kg 50VA 1.5kg 100VA 2.3kg 150VA 2.7kg 200VA 3.2kg 300VA 4.2kg 400VA 5.8kg 500VA 7.8kg 750VA 9kg Certifications and compliance 220/240 220/240 380/415 380/415 24 110 110 240 In accordance with EN61558-2-1 In accordance with CEI14-8 120 x 122 x 95 In accordance with IEC726 Wiring Diagram for TM Range All standard transformers are voltage input 0-380-415V or voltage input 0-220-240V TRANSMINAL Input Supply FORMER TERBLOCK Output Supply W- - - - - - SCREEN TO BE CONNECTED TO EARTH 0 0 150 x 155 x 125 220 380 240 415 W 0 0 0 24 110 240 NOTES Connect for: a) 0-220-240V input, EITHER 220V OR 240V only b) 0-380-415V input, EITHER 380V OR 415V only Output of transformer is centre tapped For 24V output connect between 0 and 24, for 110V output connect between 0 and 110, for 240V output connect between 0 and 240V Earth screen to be connected to screw and nut on side of transformer and to W terminal on transformer terminal block. A cable from this connection to be connected to earth 4-1 Part-enclosed Panel Transformers Order Code Primary Voltage (VAC) Secondary Voltage (VAC) TMCV30.400.24 TMCV30.400.48 TMCV30.400.110 230/400 230/400 230/400 12/24 24/48 55/110 TMCV30.400.230 50VA Rated TMCV50.400.24 TMCV50.400.48 230/400 115/230 230/400 230/400 12/24 24/48 TMCV50.400.110 TMCV50.400.230 75VA Rated TMCV75.400.24 230/400 230/400 55/110 115/230 230/400 12/24 TMCV75.400.48 TMCV75.400.110 230/400 230/400 24/48 55/110 TMCV75.400.230 100VA Rated TMCV110.400.24 230/400 115/230 230/400 12/24 TMCV110.400.48 TMCV110.400.110 TMCV110.400.230 150VA Rated TMCV115.400.24 TMCV115.400.48 TMCV115.400.110 TMCV115.400.230 200VA Rated TMCV120.400.24 TMCV120.400.48 TMCV120.400.110 230/400 230/400 230/400 24/48 55/110 115/230 230/400 230/400 230/400 12/24 24/48 55/110 TMCV120.400.230 250VA Rated TMCV125.400.24 TMCV125.400.48 TMCV125.400.110 TMCV125.400.230 300VA Rated TMCV130.400.24 TMCV130.400.48 TMCV130.400.110 TMCV130.400.230 400VA Rated TMCV140.400.24 TMCV140.400.48 TMCV140.400.110 TMCV140.400.230 500VA Rated TMCV150.400.24 TMCV150.400.48 TMCV150.400.110 TMCV150.400.230 600VA Rated TMCV160.400.24 TMCV160.400.48 TMCV160.400.110 TMCV160.400.230 230/400 Dimensions HxWxD (mm) General Characteristics Part-enclosed (IP20) single phase separation-type power transformers for electrical panels 30VA Rated TMCV Series Simple wiring via integral terminal block Dual input primary voltage (230/400V) Low loss laminations 90 x 89 x 115 Available in sizes 30VA up to 600VA DIN Rail Mountable up to 150VA Technical Characteristics 100 x 89 x 115 Thermal insulation Class B IP20 finger protection Insulation Voltage Primary/Secondary 3.5kV Max Ambient Temp 40oC Frequency 50/60Hz 110 x 89 x 115 Electrical protection Class I +/- 15V regulation tappings on primary Weights 30VA 1kg 50VA 1.6kg 75VA 2kg 100VA 2.5kg 150VA 3.2kg 200VA 3.5kg 250VA 3.9kg 300VA 5kg 400VA 6.2kg 500VA 6.9kg 115/230 600VA 7.8kg 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 Certifications and compliance 140 x 101 x 125 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 132 x 125 x 145 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 142 x 125 x 145 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 152 x 125 x 145 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 230/400 230/400 230/400 230/400 12/24 24/48 55/110 115/230 120 x 89 x 115 120 x 101 x 125 130 x 101 x 125 In accordance with EN61558-2-2 Wiring Diagram for TMCV Range All standard transformers are voltage input +15V 0 -15V 230V 400V Input Supply Output Supply TRANSFORMER TERMINAL BLOCK +15V 0 -15V 230 400 W 0 0 0 0 12 24 55 115 24 48 110 230 W- - - - - - SCREEN TO BE CONNECTED TO EARTH NOTES 162 x 125 x 145 Connect for: Input 0 - 230V connect 0 and 230V Input 0 - 400V connect 0 and 400V Input 0 - 245V connect +15V and 230V Input 0 - 415V connect +15V and 400V Input 0 - 215V connect -15V and 230V Input 0 - 385V connect -15V and 400V Output of transformer is centre tapped For 24V Output connect between 0 and 24V For 48V Output connect between 0 and 48V For 110V Output connect between 0 and 110V For 230V Output connect between 0 and 230V W terminal is connected to the terminal block. A cable from this connection to be connected to earth The full power always refers to the maximum voltage 4-2 Notes The products illustrated in this publication are subject to revision or improvement at any time. Catalogue descriptions, technical and operational data as well as other details herein specified do not have any contractual value and must be considered only as an indication. The products must be installed and used only by qualified personnel in accordance with the relevant regulations in force for electrical installations and systems in order to avoid damage or safety hazards. E.&E.O. MOTOR CONTROL PROTECTION CONTROL AND SIGNALLING CIRCUIT PROTECTION ISOLATION AUTOMATION AND CONTROL ENERGY MANAGEMENT LOVATO ELECTRIC LTD ENERGY AND AUTOMATION LOVATO HOUSE PROVIDENCE DRIVE STOURBRIDGE WEST MIDLANDS DY9 8HQ TEL 08458 110023 or 01384 899700 FAX 08458 110024 or 01384 891654 Email sales@lovato.co.uk www.lovato.co.uk