- Lovato Electric

advertisement
ISSUE
15
PLUS+
Lovato Electric. The Story of a Family, the Spirit of a Company
Lovato Electric is a proud family owned business
established in Bergamo, Italy in 1922:
the starting point of a great industrial adventure.
Our family of products feature a full range of devices
for a wide array of industry sectors:
Industrial Control, Power Factor Correction, Solar Energy, Power Generation and Energy Management.
We are proud to serve the UK market with a vast stockholding and UK starter assembly in Stourbridge, West Midlands
for same day collection or next day delivery. From here we also exclusively distribute Canalplast trunking, Cabur cable
terminals and Elca transformers.
See 1000’s of our other products in our latest General Catalogue or online at www.Lovato.co.uk
MOTOR CONTROL
PROTECTION
CONTROL AND
SIGNALLING
CIRCUIT ISOLATION
PROTECTION
Sales, Technical Support and Customer Care
Tel 08458 110 023 or 01384 899700
Fax 08458 110 024 or 01384 891654
Email sales@lovato.co.uk
Online Information
www.Lovato.co.uk
UK Head Office Address
Lovato Electric Ltd
Lovato House
Providence Drive
STOURBRIDGE
DY9 8HQ
AUTOMATION AND
CONTROL
ENERGY
MANAGEMENT
1-
Enclosed Direct On-line Starters - Polycarbonate
Enclosed Star-Delta Starters - Polycarbonate
Thermal Overload Relays
Enclosed Star-Delta Starters - Mild Steel
Manual Motor Starters
Soft Starters
AC Motor Drives
3 Pole Contactors and Polycarbonate Enclosures
Modular Contactors
Enclosed Pushbutton Control Stations
Enclosed Switch Disconnectors
DC Switch Disconnectors for Solar Applications
Steel Enclosed Switches, Fuse Switches & Changeovers
Enclosed Changeover Switches - Plastic
Rotary Cam Switches
Empty Enclosures
Limit Switches
Signal Towers & Beacons
Power Supplies
1-1
1-1
1-2
1-2
1-3
1-4
1-4
1-5
1-5
1-6
1-7
1-7
1.8
1-9
1-9
1-9
1-10
1-11
1-12
2-
CBD Series Feed-Through Terminal Blocks
CBC Series Feed-Through Terminal Blocks
Two & Three Level Terminal Blocks
Fused Terminal Blocks
Earth Terminal Blocks
High Current Terminal Blocks
Distribution Terminals
Marker Tags
End Stops, Covers & Brackets
2-1
2-2
2-3
2-3
2-3
2-3
2-3
2-4
2-4
3-
Standard Slot Panel Trunking
Narrow Slot Panel Trunking
‘EDGE’ Angular Panel Trunking
Halogen Free Panel Trunking
DIN Size Panel Trunking
Flexible Open Slot Trunking
Trunking Accessories
Spiral Wrap
3-1
3-2
3-2
3-3
3-3
3-4
3-4
3-4
4 - Open-type Panel Transformers
Part-enclosed Panel Transformers
4-1
4-2
The products illustrated in this publication are subject to revision or improvement at any time. Catalogue descriptions, technical and operational data as well as other details herein specified do not have any contractual
value and must be considered only as an indication. The products must be installed and used only by qualified personnel in accordance with the relevant regulations in force for electrical installations and systems in
order to avoid damage or safety hazards. E.&E.O.
Direct On-line
Starters
Order Code
Control
Voltage
(VAC)
Motor
Power at
400V
(kW)
Horse
Power
(HP)
Max.
Motor
Current
AC3 (A)
Dimensions
HxWxD
(mm)
Compact Direct On Line Starter (3 Phase) - Requires RF9… Overload Relay
BEST
PRICE!
DOLC5.5230
230
DOLC5.5400
400
DOLC…..
230
DOLS5.5400
400
DOLS7.5230
230
DOLS7.5400
400
DOLS11230
230
DOLS11400
400
DOLS15230
230
DOLS15400
400
Insulated polycarbonate enclosure
Operating temperature: -25...+60oC
Storage temperature: -40...+70oC
Degree of protection: IP65 (IP40 for DOLR…)
5.5
7.5
12
175 x 88 x 119
Certifications and compliance - Starters
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
Standard Direct On Line Starter (3 Phase) - Requires RF38… Overload Relay
DOLS5.5230
Operational Characteristics - Starters
5.5
7.5
12
193 x 88 x 134
*** IMPORTANT!!! ***
7.5
10
18
11
15
25
193 x 88 x 134
For DOL starters select RF…. overload relay
from page 1-2 for setting motor at full load
current (FLC)
225 x 110 x 148
15
20
28.5
Standard Direct On Line Starter With Isolator (3 Phase) - Requires RF38… Overload Relay
DOLS….
DOLSW5.5230
230
DOLSW5.5400
400
DOLSW7.5230
230
DOLSW7.5400
400
DOLSW11230
230
DOLSW11400
400
5.5
7.5
12
7.5
10
18
11
15
25
225 x 110 x 148
Direct On Line Reversing Starter FWD/STOP/REV (3 Phase) - Requires RF38… O/L Relay
DOLSW….
Star-Delta
Starters
DOLR5.5230
230
DOLR5.5400
400
DOLR7.5230
230
DOLR7.5400
400
DOLR11230
230
DOLR11400
400
Order Code
Control
Voltage
(VAC)
5.5
7.5
12
7.5
10
18
11
15
25
Motor
Power at
400V
(kW)
Horse
Power
(HP)
Max.
Motor
Current
AC3 (A)
225 x 110 x148
Dimensions
HxWxD
(mm)
YD….
230
YD11400
400
YD15230
230
YD15400
400
YD22230
230
YD22400
400
YD30230
230
YD30400
400
YDSW….
1-1
230
YDSW11400
400
YDSW15230
230
YDSW15400
400
YDSW22230
230
YDSW22400
400
YDSW30230
230
YDSW30400
400
Operating temperature: -25...+60oC
Degree of protection: IP65
11
15
22
Certifications and compliance - Starters
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
15
20
28
22
30
43
*** IMPORTANT!!! ***
30
40
60
For YD…. Star Delta Starters select RF38….
overload relay from page 1-2 for setting at 58%
of full load current (FLC)
220 x 280 x 170
Star Delta Starter With Isolator - Requires RF38… Overload Relay
YDSW11230
Insulated polycarbonate enclosure
Storage temperature: -40...+70oC
Star Delta Starter - Requires RF38… Overload Relay
YD11230
Operational Characteristics - Star Delta Starters
11
15
22
15
20
28
22
30
43
30
40
60
220 x 280 x 170
Thermal
Overload
Relays
Adjustment Range
(A)
Order Code
Three Phase
Motor at 400V
Star Delta
(kW)
RF9 Overload Relay for use with DOLC…. Starters only
RF9 1
RF9….
Three Phase Motor
at 400V DOL
(kW)
Operational Characteristics - Thermal Overload Relays
Operating temperature: -20...+55oC (RF9)
Operating temperature: -25...+60oC (RF38)
Storage temperature: -50...+70oC
0.6 -1
0.37
***
RF9 1V5
0.9 -1.5
0.55
***
RF9 2V3
1.4 - 2.3
0.75
***
RF9 33
2 - 3.3
1.1
***
RF9 5
3-5
1.5
***
RF9 75
4.5 - 7.5
2.2
***
RF9 10
6.3 - 10
4.0
***
RF9 15
9 - 15
5.5
***
Phase Failure Sensitive
Single Phase Sensitive
Certifications and compliance - Starters
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
RF38 Overload Relay for use with DOLS, DOLSW.,DOLR ,YD and YDSW Star Delta Starters
RF38….
RF38 0100
0.63 - 1
0.25
***
RF38 0160
1 - 1.6
0.55
***
RF38 0250
1.6 - 2.5
0.75
***
RF38 0400
2.5 - 4
1.5
2.2 - 3
RF38 0650
4 - 6.5
2.2
4
RF38 1000
6.3 - 10
4
5.5 - 7.5
RF38 1400
9 - 14
5.5
11
RF38 1800
13 - 18
7.5
15
RF38 2300
17 - 23
11
18.5
RF38 3200
24 - 32
15
22
RF38 3800
32 ~ 38A
18.5
30
Indicated powers apply to 4-Pole motors; it is advisable to always check the nameplate motor
current is within the relay adjustment range.
Steel Enclosed
Star-Delta
Starters
Order Code
Control
Voltage
(VAC)
Motor
Power at
400V
(kW)
Horse
Power
(HP)
Max.
Motor
Current
AC3
(A)
Dimensions
HxWxD
(mm)
Hinged door mild steel enclosure with painted finish and supplied
complete with fitted thermal overload relay and isolator.
Operational Characteristics
Operating temperature: -25...+60oC
Star Delta Starter With Isolator - Overload included
Storage temperature: -40...+70oC
SDSI 11415
400
11
15
22
SDSI 15415
400
15
20
28
SDSI 22415
400
22
30
42
SDSI 30415
400
30
40
56
SDSI 45415
400
45
60
83
SDSI 55415
400
55
75
98
SDSI 75415
400
75
100
135
Degree of protection: IP65
300 x 300 x 200
Certifications and compliance - Starters
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
500 x 400 x 200
SDSI...
1-2
Manual Motor
Starters
Thermal Trip Adjustment
Range
Order Code
Short Circuit Breaking
Capacity (IEC) at 400V
(A)
Icu
Ics
(kA)
(kA)
IEC Breaking Capacity Icu at 400V: 100kA (0.1 - 6.3A) /
4kA (10 - 25A) at 400V / 6kA (6.3 - 10A)
11 LMS25….
11 LMU...
11 LMH11
General Characteristics - LMS25 Range
The LMS25 manual motor starter is particularly suitable for controlling
small operating machines. Releases and auxiliary contacts make it also
suitable for more complex uses. Wall and flush-mount enclosures all to
install the LMS25 starter in the most disparate environmental conditions
(dust, humidity, aggressive environmental agents etc.)
Operational Characteristics - LMS25 Range
11 LMS25 016T
0.1 - 0.16
100
100
11 LMS25 025T
0.16 - 0.25
100
100
IEC rated insulation voltage Ui: 690V. IEC rated impulse
withstand voltage: 6kV. IEC rated frequency: 50/60Hz
11 LMS25 04T
0.25 - 0.4
100
100
Power dissipation: 2 - 15W. Magnetic tripping: 12In max
11 LMS25 063T
0.4 - 0.63
100
100
IEC thermal tripping class: 10
11 LMS25 1T
0.63 - 1
100
100
11 LMS25 1V6T
1 - 1.6
100
100
11 LMS25 2V5T
1.6 - 2.5
100
100
11 LMS25 4T
2.5 - 4
100
100
11 LMS25 6V3T
4 - 6.3
100
100
11 LMS25 10T
6.3 - 10
6
3
11 LMS25 16T
10 - 16
4
2
11 LMS25 20T
16 - 20
4
2
11 LMS25 25T
20 - 25
4
2
Order Code
Phase failure/Single phase sensitive
Mechanical life: 100,000 cycles. Electrical life 25A (IEC
AC3): 100,000 cycles
Mounting on 35mm DIN rail (IEC/EN 60715) or screw fixing
IEC utilisation category: A. IEC degree of protection: IP20
Certifications and Compliance - LMS25 Range
Certifications obtained: GOST: UL Listed for USA and Canada (File
E155982). See UL/CSA details under NOTE below bottom table.
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2 IEC/EN
60947-4-1, UL508, CSA C22.2 n° 14
NOTE: When more than one breaker are mounted, side by side, without
leaving space between each to consent free air circulation on the
breaker sides, and have simultaneous operation, the thermal trip
adjuster must be positioned at a value 15% greater than the rated
motor current.
Characteristics
Add-on Auxiliary Contacts. Side Mount
11 LMH 11
11 LMZ106
Operational Characteristics
ADD-ON AUXILIARY CONTACTS
1NO + 1NC
Undervoltage Trip Release
11 LMU ❶
Connectable to right or left side of starter
To fit inside starter. For all LMS25
Maximum combination: 2 x LMH blocks, one on right and one
on left side of starter. (4 auxiliary contacts max in total)
To fit inside starter. For all LMS25
IEC rated insulation voltage Ui: 500V. IEC conventional free
air thermal current Ith: 6A
Shunt Trip Release
11 LMA ❶
Enclosures
11 LMZ 111
Surface mount - IP55. 80mm/3.15” wide
11 LMZ 113
Flush mount - IP55. 85mm/3.35” wide
IEC operational current AC15: 3.5A 230V; 2A 400V
Protection fuse (gL or gG): 6A maximum
Conductor cross section minimum-maximum (1 or 2 wires):
0.75-2.5mm2 or 18/14AWG
Red Emergency Stop Button - IP55 Protection
11 LMZ 106
11 LMZ111
Width of the auxiliary contacts LMH... equal to 0.5 standard
DIN43880 modules.
For LMZ 111 and LMZ 113 - Turn to release Ø 35mm/1.38”
❶ Specify rated voltage. Add suffix 60 if frequency is 60Hz. Available voltages:
- AC 50Hz
24/48/110/220-240 (indicate 220)
380 - 415 (indicate 380)/ 440 - 460 (indicate 440)/ 480 - 575VAC
NOTE - An extensive range of accessories can be found in our latest General Catalogue.
UNDERVOLTAGE AND SHUNT TRIP RELEASES
Must be fitted inside the motor starter.
Maximum UL/CSA Horsepower Rating
Type
Thermal adjustment
range ❷
3 Phase (HP)
1 Phase (HP) ❸
FLA max at
600V
(A)
120V
230V
200-208V
230V
480V
600V
(A)
LMS25 016T
0.1 - 0.16
—
—
—
—
—
—
0.16-
LMS25 025T
0.16 - 0.25
—
—
—
—
—
—
0.25
LMS25 04T
0.25 - 0.4
—
—
—
—
—
—
0.4
LMS25 063T
0.4 - 0.63
—
—
—
—
—
—
0.63
LMS25 1T
0.63 - 1
—
—
—
—
—
½
1
LMS25 1V6T
1 - 1.6
—
—
—
—
¾
¾
1.6
LMS25 2V5T
1.6 - 2.5
—
⅙
½
½
1
1½
2.5
LMS25 4T
2.5 - 4
⅛
¼
¾
1
2
3
4
LMS25 6V3T
4 - 6.3
¼
½
1½
1½
3
5
6.3
LMS25 10T
6.3 - 10
½
1
2
3
5
7½
10
LMS25 16T
10 - 16
1
2
3
5
10
10
16
LMS25 20T
16 - 20
1½
3
5
5
10
15
20
LMS25 25T
20 - 25
2
3
5
7½
15
20
25
NOTE: UL Listed in USA and Canada as manual motor controller. Fuses only 30A suitable for use on a circuit capable of delivering not more
than 5000rms symmetrical amperes, 600VAC. Trip current is 125%.
❷ The appropriate thermal trip range of the controller should be selected on the basis of the motor nameplate full-load current since the
horsepower ratings given are for indication and reference purposes only.
❸ Single-phase horsepower ratings are based on wiring the three poles in series.
1-3
Release range
Operating range
On-load factor
Undervoltage
Shunt
0.35 - 0.7Us
0.85 - 1.1Us
100%
—
0.7 - 1.1Us
—
SURFACE MOUNT ENCLOSURE
Top or bottom entry: M25 threaded knockouts
Rear entry: 15.5mm/0.6” knockouts
Operating termperature: -5...+40°C.
Storage termperature: -50...+80°C.
FLUSH MOUNT ENCLOSURE
Window size 70x115mm/2.76x4.53”
Operating termperature: -5...+40°C.
Storage termperature: -50...+80°C.
Certifications and Compliance - Accessories
Certifications obtained: GOST for all; UL Listed for USA and
Canada (File E155982), under motor controllers, for
auxiliary contacts and trip releases.
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-5-1, UL508, CSA C22.2 n° 14.
Soft
Starters
Order Code
IEC Rated Starter
Current Ie in AC-53b
Rated Motor Power
(A)
IEC
(kW)
UL/CSA
(HP)
With Integrated By-pass Relay. 110-400VAC Auxiliary Supply.
Three-phase 400VAC Motor Control.
General Characteristics
ADXC… is a compact type of soft starter, 45mm wide and easy to use,
for three phase squirrel-cage induction motors; soft starts and soft stops
rated motor load currents up to 45A.
It is based on a current limiting starting methodology to limit the
maximum starting current. ADXC… reduces the mechanical load on
motor shafts, gearboxes and drive belts.
Ramp up, ramp down and initial voltage time settings can be
independently adjusted by built-in potentiometers.
Main features are:
ADXC 012 400
12
5.5
3
ADXC 016 400
16
7.5
7.5
ADXC 025 400
25
11
10
For 3ph induction motors up to 22kW / 25HP at 400VAC
ADXC 032 400
32
15
15
Maximum input voltage: 400VAC 50/60Hz
ADXC 037 400
37
18.5
20
Built-in bypass relay
ADXC 045 400
45
22
25
Wrong phase sequence and over temperature protection
We offer an extensive range of soft starters which can be found in our latest General
Catalogue, or our website or contact our sales office for more information.
Current Control
ADXC… gradually increases the current limit at 75% ramp-up time if the motor speed has yet
to reach rated value, to avoid locked rotor state before time elapsing
ADXC…..
Alarm for wrong phase sequence; line voltage and/or
frequency out of limits (over and undervoltage); overcurrent,
over temperature, irregular ramp up and current flow during
bypass; motor voltage unbalance
Simple setting and installation
2 relay outputs for alarms (NC) and bypass closing
35mm DIN rail mounting (IEC/EN 60715)
Ideal for hydraulic lifts, conveyor belts, compressors, pumps,
hoisting devices, blowers, fans, mixers.
Operational characteristics
Number of controlled phases: 2
Input voltage L1-L2-L3: 220-400VAC -15%...+10%
ADXC…. Adjustments
Frequency range: 50/60Hz ±10% self-configurable
Separate single phase auxiliary power supply A1-A2:
Start command: A1-A2 110…400VAC -15%...+10%
Ramp up time: 1-20 secs, Ramp down time: 0-20 secs
3 x Alarm indication LEDs
A Initial voltage : 0-85% of motor control power
Degree of protection: IEC IP20.
B Ramp Up Time: 1-20 seconds, Initial to max load voltage time.
C Ramp Down Time: 0-20 seconds. Max to no load voltage time.
AC Motor
Drives
Order Code
Output
Current
(A)
Dimensions
WxHxD
Output Power
(kW)
(HP)
(mm)
VE1 02 A240
1.8
0.2
0.25
VE1 04 A240
2.6
0.4
0.54
VE1 07 A240
4.3
0.75
1
VE1 15 A240
7.5
1.5
2
VE1 22 A240
10.5
2.2
3
Working temperature: -10…+40°C (50°C with fan or 20%
current de-rating)
Relative humidity: 95%
Built-in EMC filter 1° Environment, Category C2 (EN61800)
Group 1, Class A (EN55011)
72 x 131 x 139
118 x 131 x 147
NOTE: 5cm minimum required for side by side installations.
CD software and instruction manual included.
VE1
Description
Control mode: V/f (6 fixed curves, 1 programmable). Torque
boost
Digital input/outputs: 5 programmable inputs (pNp),
1 programmable output (250VAC/1A - 30VDC/1A)
Analogue input/outputs: 1 input - 0...10V, 0/4...20mA
1 output - 0...10V
Output frequency setting: Front panel (▲▼ keys or
potentiometer), Digital inputs (8 selections, with independent
acceleration/deceleration times), Communication protocol
Motor start and stop: Front panel (RUN and STOP keys),
Digital inputs (2 or 3 wire control)
Built-in communication port: RS485 (RJ45), modbus RTU
and modbus ASCII
Accessories
VEX C00
General Characteristics
Output frequency range: 0...650Hz
Input: Single phase 200...240VAC
Output: 3-phase 0...240VAC - 0...650Hz (EMC filter built-in)
Order Code
Certifications and compliance
Certifications obtained: UL Listed for USA and Canada (cULus – File
E223223) under Solid State Motor Controllers as reduced voltage
starters; EAC and CCC pending completion at time of catalogue printing. Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-2, UL
508, CSA C22.2 n°14.
RS485 (RJ45) - PC (USB) Connection Cable
IP protection: IP20
Further technical data is available on our website www.Lovato.co.uk or contact our sales office.
We offer an extensive range of AC motor drives which can be found in our latest General
Catalogue or contact our sales office for more information.
1-4
Three-pole
Contactors
Order Code
IEC Operating
Current Ith
AC1 (≤ 40°C)
(A)
Ie (AC3)
≤ 440V at
≤ 55°C
(A)
Incorporated
Auxiliary
Contacts
Type of
Terminal
11BG09 10 A***
20
9
1 N/O
Clamp-screw
11BG12 10 A***
20
12
1 N/O
Clamp-screw
3 Pole Contactors with AC Control Circuit
BF09A to BF25A
Quick connect - snap on accessory mounting
Distinct contact status indication
DC versions also available
Screw or 35mm Din rail fixing (IEC/EN 60715)
BF09 10 A***
25
9
1 N/O
Clamp-screw
BF12 10 A***
28
12
1 N/O
Clamp-screw
BF18 10 A***
32
18
1 N/O
Clamp-screw
BF25 10 A***
32
25
1 N/O
Clamp-screw
BF26 00 A***
45
26
—
Clamp-screw
BF32 00 A***
56
32
—
Clamp-screw
BF38 00 A***
60
38
—
Clamp-screw
DC Versions also available
11 BF50 00***
90
50
—
Allen-screw
Screw or 35mm Din rail fixing (IEC/EN 60715)
11 BF65 00***
110
65
—
Allen-screw
Certifications - UL, CSA (Canada only), GOST, CCC, RINA
11 BF80 00***
125
80
—
Allen-screw
General Characteristics and Certifications - BF50 to BF110 Contactors
11 BF95 00***
125
95
—
Allen-screw
11 BF110 00***
125
110
—
Allen-screw
*** Complete with AC coil voltage 50/60Hz - 024, 110, 230, 400V
BF50 - BF110
Operating temperature: -40...+60oC
Storage temperature: -55...+70oC
3 Pole Mini-contactors with AC Control Circuit
BG Contactors
General Characteristics and Certifications - BG Mini-contactors
Certificates - UL, GOST, CCC
General Characteristics and Certifications - BF09 to BF38 Contactors
Operating temperature: -50...+70oC
Storage temperature: -60...+80oC
Quick connect - snap on accessory mounting
Four terminal coil
Operating temperature: -50...+70oC
Storage temperature: -60...+80oC
Quick connect - snap on accessory mounting
Add-on Blocks for BG Type Mini-contactors
DC Versions also available
11 BGX10 11
Screw Type Auxiliary Contact 1NO + 1NC
Screw or 35mm and 75mm Din rail fixing (IEC/EN 60715)
11 BGX10 02
Screw Type Auxiliary Contact 2NC
11 BGX10 20
Screw Type Auxiliary Contact 2NO
Certifications - UL, CSA (Canada only), GOST, CCC, RINA
(except BF110), LROS (except BF110)
11 BGX 5000
Mechanical Interlock for BG Contactors
All contactors are compliant with standards - IEC/EN 60947-1, IEC/EN
60947-4-1, UL508, CSA C22.2 n° 14.
Add-on Blocks for BF Type Contactors
BFX1011
BFX10 11
Screw Type Auxiliary Contact 1NO + 1NC (front centre mount)
BFX10 02
Screw Type Auxiliary Contact 2NC (front centre mount)
BFX10 20
Screw Type Auxiliary Contact 2NO (front centre mount)
BFX10 22
Screw Type Auxiliary Contact 2NO + 2NC (front centre mount)
BFX 5000
Mechanical Interlock for BF09 to BF38 Contactors
11 G2692
Mechanical Interlock for BF50 - BF110 Contactors
Note - Four pole contactors and an extensive range of accessories can be found in our latest
General Catalogue from www.Lovato.co.uk or contact our sales office for more information.
Modular
Contactors
Order Code
IEC Rated Current
Ith in AC-1
(A)
Two Pole 220-230V AC
Contact Configuration
N.O.
N.C.
CN20 11 220
20
CN20 20 220
20
25
CN25 01 220
CN40 10 220
1
1
Equipped with 2 or 4 closing contacts of equal capacity
permitting use in power or auxiliary circuits
--
2
0
Operation flag indicator
Fast mounting.
4.0
4
0
25
4.0
3
1
40
11.0
4
0
CN40 01 220
40
11.0
3
1
CN63 10 220
63
15.0
4
0
CN63 01 220
63
15.0
3
1
Auxiliary Contacts (one max per contactor)
1-5
DC powered magnetic core system assuring silent
operation and noise damping during the control phase
--
(For 24V AC/DC version change CN…….220 code to CN……...024)
CN25 10 220
Operational Characteristics
Overvoltage protection circuit and voltage peak limitation
of the magnetic core
(For 24V AC/DC version change CN…….220 code to CN……...024)
Three or Four Pole 220-230V AC
CN40…, CN20...
Rated Motor
Power
IEC
(kW)
CNH 11
6
--
1
1
CNH 20
6
--
2
0
Noise level: Closed contactor ≤20dB
Making/breaking operation ≤50dB
IEC degree of protection: IP20
Mounting on 35mm DIN rail (IEC/EN 60175).
Certifications and compliance
Compliant with standards: IEC/EN 60947-1, 60947-4-1,
60947-5-1 and 61095
Enclosed
Control
Stations
General Characteristics
Order Code
Description
Operating temperature: -20...+55oC (RF9)
Operating temperature: -25...+60oC (RF38)
1 Gang Plastic Enclosure Grey Cover
S1P10
Standard Green PB "I" (START) c/w 1NO contact
S1P01
Standard Red PB "O" (STOP) c/w 1NC contact
S1P33
Double Touch PB "I/O" (START/STOP) c/w 1NO & 1NC contacts
S1PK02
Key Switch 2 pos "I-O" c/w 1NO contact
S1PK05
Key Switch 3 pos "I-O-II" c/w 2NO contact
S1PSW7
Selector Switch 2 pos "I-O" c/w 1NO contact
S1PSW9
Selector Switch 3 pos "I-O-II" c/w 2NO contact
Storage temperature: -50...+70oC
Degree of protection (Plastic): IP66, IP67, IP69K
Degree of protection (Stainless): IP65
Base mounted contact blocks (plastic enclosures)
Any combination of up to 6 gang stations available upon
request and subject to availability
Certifications and compliance
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
1 Gang Plastic Enclosure Yellow Cover
S1P10
S1PY71
40mm Mushroom Twist Reset (STOP) c/w 1NC contact
S1PY81
40mm Mushroom Key Reset (STOP) c/w 1NC contact
S1PY91
40mm Mushroom Twist Reset (EMERGENCY STOP) c/w 1NC contact
2 Gang Plastic Enclosure Grey Cover
S2P1001
S2P1071
S2P1091
Standard Green "I" PB's (START/STOP) c/w 1NO & 1NC contacts
Standard Green "I" & 40mm Mushroom Twist Release PB's
(START/STOP) c/w 1NO & 1NC contacts
Standard Green "I" & 40mm Mushroom Twist Release EN418 PB's
(START/EMERGENCY STOP) c/w 1NO & 1NC contacts
3 Gang Plastic Enclosure Grey Cover
S1PY91
S3P101110
2x Standard Black "↑" & 1x Standard Red "O" PB's (FWD/STOP/REV)
S3P107110
2x Standard Black "↑" & 1x 40mm Mushroom Twist Release PB's
S3P109110
2x Standard Black "↑" & 1x 40mm Mushroom Twist Release EN418
1 Gang Stainless Steel Enclosure
S2P1001
S1S10
S1S10
Standard Green PB "I" (START) c/w 1NO contact
S1S01
Standard Red PB "O" (STOP) c/w 1NC contact
S1S33
Double Touch PB "I/O" (START/STOP) c/w 1NO & 1NC contacts
S1SK02
Key Switch 2 pos "I-O" c/w 1NO contact
S1SK05
Key Switch 3 pos "I-O-II" c/w 2NO contact
S1SW7
Selector Switch 2 pos "I-O" c/w 1NO contact
S1SSW9
Selector Switch 3 pos "I-O-II" c/w 2NO contact
S1S71
40mm Mushroom Twist Reset (STOP) c/w 1NC contact
S1S81
40mm Mushroom Key Reset (STOP) c/w 1NC contact
S1S91
40mm Mushroom Twist Reset (EMERGENCY STOP) c/w 1NC contact
2 Gang Stainless Steel Enclosure
S2S1001
Standard Green "I" PB's (START/STOP) c/w 1NO & 1NC contacts
S2S1071
Standard Green "I" & 40mm Mushroom Twist Release PB's
S2S1091
Standard Green "I" & 40mm Mushroom Twist Release EN418 PB's
S1S91
1-6
Enclosed
Switch
Disconnectors
GAZ…..
Order Code
IEC Conventional Free
Air Thermal Current Ith
AC21A (≤690V)
(A)
Dimensions
HxWxD
(mm)
3 Pole Switch Disconnector with Red/Yellow Handle in Polycarbonate Enclosure
GAZ016
16
GAZ025
25
GAZ032
32
GAZ040
40
GAZ063*
63
GAZ080*
80
GAZ100*
100
GAZ125*
125
Operational Characteristics Operating temperature: -25...+60oC
Storage temperature: -40...+70oC
Chemical resistant polycarbonate (GAZ... or stainless steel
enclosure (GAZS…)
Degree of protection: IP65
159 x 100 x 97
Padlockable handle
Add fourth pole GAX42…… for four pole version
280 x 220 x 170
Cable entries:
GAZ016 - GAZ040: 4 x M20 / M25 dual knockouts
GAZ063 - GAZ125 and GAZS016 - GAZS125
smooth walls to be drilled by installer
Cable capacities
GAZ(S)016 - GAZ(S)040 = 16mm2
GAZ(S)063 - GAZ(S)125 = 50mm2
*GAZ063-GAZ125 supplied without earth terminals
Certifications and compliance - Starters
3 Pole Switch Disconnector with Red/Yellow Handle in Satin Stainless Steel Enclosure
GAZS….
GAZS016
16
GAZS025
25
GAZS032
32
GAZS040
40
GAZS063
63
GAZS080
80
GAZS100
100
GAZS125
125
Compliant with standards: IEC/EN 60947-3 and
IEC/EN 60947-1
170 x 100 x 100
285 x 185 x 130
Switched Fourth Pole Add-On
GAX42….
GAX42040A
16 - 40
GAX42063A
63
Fits GAZ(S)016 - GAZ(S)040
Fits GAZ(S)063
GAX42080A
80
Fits GAZ(S)080
GAX42100A
100
Fits GAZ(S)100
GAX42125A
125
Fits GAZ(S)125
Add-On Blocks
GAX1011A
1NO+1NC Auxiliary contact block fits all types
GAX31A
Neutral Terminal for GAZ(S)016 - GAZ(S)040 Types
GAX32A
Neutral Terminal for GAZ(S)063 - GAZ(S)125 Types
GAX33A
Earth Terminal for GAZ(S)016 - GAZ(S)040 Types
GAX34A
Earth Terminal for GAZ(S)063 - GAZ(S)125 Types
GAX1011A….
DC Switch
Disconnectors
For Solar
Applications
Order Code
Current Rating
Ith
(A)
Dimensions
HxWxD
(mm)
40
GAZ080DT4B
80
GAZ125DT4B
125
159 x 100 x 97
280 x 220 x 170
GAZ040DT4B
1-7
Storage temperature: -40...+70oC
Degree of protection: IP65
Padlockable handle
IEC Rated insulation voltage Ui: 1000VDC
Rated operational current Ie DC21B for devices at operational voltages:
Operating Voltage
Insulated polycarbonate enclosure
Operating temperature: -25...+60oC
Switch Disconnector for DC Switching and Solar Applications
GAZ040DT4B
Operational Characteristics
Certifications and compliance - Starters
GAZ040DT4B
GAZ080DT4B
GAZ125DT4B
Up to 48VDC
40A
80A
125A
Up to 110VDC
35A
70A
120A
Up to 400VDC
35A
40A
64A
Up to 500VDC
32A
40A
56A
Up to 600VDC
20A
30A
40A
Up to 700VDC
15A
18A
20A
Up to 800VDC
15A
18A
20A
Compliant with standards: IEC/EN 60715
Enclosed
Switchfuse
Isolators
Order Code
Current Rating
Ith
(A)
Dimensions
HxWxD
(mm)
IP65 Switchfuse Isolator supplied with 10x38mm gG Fuses
GAZ020F
20
GAZ032F
32
Operational Characteristics
Insulated polycarbonate enclosure: IP65
Operating temperature: -25...+60oC
Storage temperature: -40...+70oC
234 x 110 x 97
Includes switched fourth pole & padlockable handle
For use with 10x38 gG fuse types
Cable entries: 4 x M20 / M25 dual knockouts
Certifications and compliance
Compliant with standards: IEC/EN 60947-1 and
IEC/EN 60947-3
GAZ….F
Steel Enclosed
Switch
Disconnectors,
Switchfuses,
Changeover
Switches
IEC Conventional Free
Dimensions inc Handle
Air Thermal Current Ith
HxWxD
AC23A (≤690V)
(mm)
(A)
3 Pole Switch Disconnector with Red/Yellow Handle in Steel Enclosure with fitted neutral
disconnect link
Order Code
GEZ0063
63
GEZ0100
100
GEZ0160
160
GEZ0250
250
GEZ0400
400
GEZ0630
630
300 x 300 x 246
GEZ…. GEZ….N
63
GEZ0100N
100
GEZ0160N
160
GEZ0250N
250
GEZ0400N
400
GEZ0630N
630
Operating temperature: -25...+60oC
Storage temperature: -40...+70oC
Ratings up to 630A
Pressed steel enclosure: IP65 in RAL7035
Padlockable handles
Generous wiring space
400 x 300 x 246
500 x 400 x 295
700 x 500 x 310
3 Pole Fuse Switch with Red/Yellow handle in steel enclosure with fitted neutral link and
fuses
GEZ0063N
Operational Characteristics
500 x 400 x 245
500 x 400 x 295
800 x 600 x 310
Supplied with al cable shrouds
Earth link to door fitted
Disconnectable neutral link with shroud*
Supplied with NH Fuses (NFC for 63A-100A)**
Standard replaceable components
Gland plate fitted to bottom
Certifications and compliance
Compliant with standards: IEC/EN 60947-3 and
IEC/EN 60947-1
* Not fitted to changeover switches
** Fused switches only
1000 x 600 x 360
4 Pole Changeover Switches with Black handle in steel enclosure
GEZ0063ET4
63
GEZ0100ET4
100
GEZ0160ET4
160
400 x 300 x 260
GEZ0250ET4
250
500 x 400 x 260
GEZ0400ET4
400
500 x 400 x 310
GEZ0630ET4
630
700 x 500 x 310
300 x 300 x 235
GEZ….E
Neutral Link
Standard Lovato Switches
& Fuse Switches
Fully Shrouded
Door Earth Link
Gland Plate
1-8
Enclosed
Changeover
Switches
GX….P
Rotary Cam
Switches
ON/OFF
Current
Rating AC1
(A)
Order Code
Dimensions
HxWxD
(mm)
3 Pole Changeover Switch with Black Handle in Polycarbonate Enclosure—centre off
GX16 53 P
16
90 x 90
GX20 53 P
20
90 x 90
GX32 53 P
32
110 x 110
GX40 53 P
40
110 x 110
Insulated plastic enclosure
Operating temperature: -25...+55oC
Storage temperature: -40...+70oC
Degree of protection: IP65
Top and bottom cable entry: 4 PG16 threaded knockouts for
90 x 90mm types and PG21 for 110 x 100mm types.
Certifications and compliance
4 Pole Changeover Switch with Black Handle in Polycarbonate Enclosure—centre off
Certifications obtained: GOST
GX16 75 P
16
GX20 75 P
20
90 x 90
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-3 , IEC/EN 60947-5-1, IEC/EN 61058-1
GX32 75 P
32
110 x 110
GX40 75 P
40
110 x 110
Order Code
Current
Rating AC1
(A)
Front Plate Size
(mm)
90 x 90
Operational Characteristics
Operating temperature: -25...+55oC
Storage temperature: -40...+70oC
Front Mount - One pole - 1 Wafer - ON/OFF Switches
GX16 90 U
16
48
GX20 90 U
20
48
GX32 90 U
32
65
GX40 90 U
40
65
IEC 16 to 40A conventional free air thermal current Ith
ratings
IEC IP65 front degree of protection; IEC IP20 protection of
contacts
Rotation angles: 30° , 45° , 60° and 90°
Certifications and compliance
Front Mount - Two pole - 1 Wafer - ON/OFF Switches
GX….U
Operational Characteristics
GX16 91 U
16
48
GX20 91 U
20
48
GX32 91 U
32
65
GX40 91 U
40
65
Certifications obtained: GOST; UL Listed for USA and
Canada (File E155982) as Manual Motor Controllers
Compliant with standards: IEC/EN 60947-1,
IEC/EN 60947-3 , IEC/EN 60947-5-1, IEC/EN 61058-1,
UL508, CSA C22.2 n° 14
Example of U Version Switch Mounting
Front Mount - Three pole - 2 Wafers - ON/OFF Switches
GX16 10 U
16
48
GX20 10 U
20
48
GX32 10 U
32
65
GX40 10 U
40
65
Note - Our extensive range of rotary cam switches can be found in our General Catalogue
available on request from our sales office
Empty
Enclosures
M0N
Suitable for LOVATO
Contactor Type
(to be ordered
separately)
Suitable for LOVATO Thermal Relay
Type
(to be ordered
separately)
Dimensions
H x W x D (mm)
M0N
BG06
BG09
BG12
RF9
184 x 88 x 119.5
M1N
BF09A
BF12A
BF18A
RF38
202 x 88 x 134.5
M2N
BF25A
BF26A
BF32A
RF38
234 x 110 x 148.5
Order Code
M24N (inc mount plate)
All Above
M25N (inc mount plate)
All Above + BF38
M3N
M3N
BF38A
BF50, BF65
BF80, BF95
BF110
Operational Characteristics
1-9
—
Operating temperature: -25...+60oC
Storage temperature: -40...+70oC
Degree of protection: IP65
M0N, M1N and M2N have moulded din rail mount in base of
enclosure and have external fixings to maintain IP rating
M3N has a hinged lid and requires mounting plate MX30 for
fitting of devices
Certifications and compliance
Compliant with standards: IEC/EN 60947-1 and IEC/EN
60947-4-1
210 x 175 x 98.5
RF38
RF953 *
210 x 175 x 158.5
280 x 220 x 170
Metal Mounting Plate for M3N Enclosure
MX30
Insulated polycarbonate enclosure
—
185W x 240H mm
* For thermal overload relay (RF952) to use with BF38A contactor,
please contact our customer services.
Limit
Switches
Order Code
Description
Limit Switch body dimensions to EN50047 — order operating head separately below
KXCBS11
KXCMS11
KXCCS11
KXCNS11
KXCBS11
Plastic body, one bottom M20 cable entry, 1NO+1NC snap action
KXCMS11
Metal body, one bottom M20 cable entry, 1NO+1NC snap action
KXCCS11
Plastic body, two side M20 cable entry, 1NO+1NC snap action
KXCNS11
Metal body, two side M20 cable entry, 1NO+1NC snap action
Operating Heads to Fit KX… Limit Switch Bodies
KXA1
KXB...
KXC...
KXD...
KXE...
General Characteristics
The KX C... bodies, complete with auxiliary contacts, can be coupled
with the KX A... operating heads, to obtain complete limit switches in the
required configurations. The body cover is hinged at the bottom and
removable to have the best access. Each body includes the innovative
locking bayonet mechanism of the operating head. Plastic and metal
types are available.
The heads are made of metal and warrant sturdiness and operating
reliability in all conditions. The shape of the coupling section with the
body of the K series switches permits to orient the head in any 45°
angle position while the initial lever and rod position can be adjusted
360° at 15° angle positions. The head fixing to the body is achieved by
the innovative locking bayonet mechanism so
there is no need of tools.
KXA A1
Top push rod plunger
KXA B1
Plastic top roller push plunger
KXA B2
Metal top roller push plunger
KXA C1
Plastic roller centre push lever
IEC thermal current Ith: 10A
KXA C2
Metal roller centre push lever
KXA D1
Plastic roller side push lever
KXA D2
Metal roller side push lever
IEC rated insulation voltage Ui:
690VAC for KX CB-KX CC types
440VAC for KX CM-KX CN types
KXA E1
Plastic roller lever plunger
KX CB-KX CC types Self-extinguishing double-insulation polymer thermoplastic
KXA E2
Metal roller lever plunger
KX CM-KX CN types - Aluminium-zinc alloy
KXA E3
Rubber Ø50x10mm roller lever plunger
Cable entry: M20 standard supplied
KXA F1
Adjustable plastic roller lever Ø19x5mm
Operating head fixing: Locking bayonet insert
KXA F2
Adjustable metal roller lever Ø19x5mm
Cable connection: Self-releasing screw terminal
KXA F3
Adjustable rubber Ø50x10mm roller lever
KXA F4
Adjustable offset rubber Ø50x10mm roller lever
KXA H1
Ceramic rod lever
KXA L1
Adjustable plastic rod lever
KXA L2
Adjustable stainless steel rod lever
KXA M1
Flexible wobble stick
KXA M2
Semi-rigid wobble stick
Operational characteristics
Mechanical life: >10 million cycles
Conductor section: 1 or 2 2.5mm2 max / 16-14 AWG
• Operating temperature: -25 ... +70°C
• Storage temperature: -40 ... +70°C
• IEC degree of protection: IP65 for body housing.
Certifications and compliance
Certifications obtained: EAC for all, UL Listed for US and Canada (File
E93601), as Auxiliary Devices for KX C... body types only. UL Recognized for USA and Canada (cURus - File E93601) as component Comply with standards: EN50047, IEC/EN 60947-1,
KXE3
See General Catalogue for the full range of limit, micro and foot
switches or online at www.lovato.co.uk
KXF...
KXF4
Foot
Switches
KXH1
KXL...
Order Code
KXM1
KXM2
Description
Plastic Body Foot Switch M20 Cable Entry
KG100S11
KG100 S11
Open foot switch with 1NO+1NC action contacts
KG200 S11
Foot switch with 1NO+1NC action contacts—with cover
KG110 S11
Open foot switch with 1NO+1NC action contacts c/w safety lever
KG210 S11
Foot switch with 1NO+1NC action contact c/w cover and safety lever
KG120 S11
Open foot switch with 1NO+1NC action contacts c/w actuator lock
KG220 S11
Foot switch with 1NO+1NC action contacts c/w cover and actuator lock
Metal Body Foot Switch M20 Cable Entry
KG210S11
Thermoplastic or metal version
Versions complete with or without pedal protection cover
The cover assures protection against accidental operation,
due to sudden tool or heavy material dropping on switch.
Versions with safety lever; The safety mechanism prevents
unintentional foot switch activation and excludes the pedal
pressing if the operator’s foot is not completely in place.
KR100 S11
Open foot switch with 1NO+1NC action contacts
KR200 S11
Foot switch with 1NO+1NC action contacts—with cover
KR110 S11
Open foot switch with 1NO+1NC action contacts c/w safety lever
KR210 S11
Foot switch with 1NO+1NC action contact c/w cover and safety lever
Mechanical life: >10 million cycles
KR120 S11
Open foot switch with 1NO+1NC action contacts c/w actuator lock
Conventional thermal current Ith: 10A
KR220 S11
Foot switch with 1NO+1NC action contacts c/w cover and actuator lock
See General Catalogue for the full range of foot switches or online at www.lovato.co.uk
KR210S11
General characteristics
The KG and KR foot switches are used to control machinery and other
equipment, leaving the operator’s hands free to do other functions.
Operational characteristics
Designation to IEC/EN 60947-5-1:
Class II insulation (KG types only)
Operating temperature: -25 ... +70°C
1-10
Signal
Towers and
Beacons
Order Code
Description
Signal Tower Kits—Steady Light—do not include bulbs, see bottom of page
LT7KIT-R
RED Lens 8LT7EL4 steady light module with BA15d lamp fitting c/w
8LT7CP01 connection module and 8LT7BP01 surface mount base with
100mm extension.
LT7KIT-G
GREEN Lens 8LT7EL3 steady light module with BA15d lamp fitting c/w
8LT7CP01 connection module and 8LT7BP01 surface mount base with
100mm extension.
LT7KIT-RG
RED+GREEN Lens 8LT7EL... steady light modules, BA15d lamp fitting
c/w 8LT7CP01 connection module and 8LT7BP01 surface mount base
with 100mm extension.
LT7KIT-RYG
RED+YELLOW+GREEN Lens 8LT7EL... steady light modules, BA15d
lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01 surface
mount base with 100mm extension.
LT7KIT-RYGB
RED+YELLOW+GREEN+BLUE Lens 8LT7EL... steady light modules,
BA15d lamp fitting c/w 8LT7CP01 connection module and 8LT7BP01
surface mount base with 100mm extension.
LT7KIT-RYGBW
RED+YELLOW+BLUE+GREEN+WHITE Lens 8LT7EL... steady light
modules, BA15d lamp fitting c/w 8LT7CP01 connection module and
8LT7BP01 surface mount base with 100mm extension.
LT7KIT-G
General Characteristics - Signal Towers
Signal towers are fundamental elements in manufacturing processes for
the visual and audible signalling of the system status.
The signal towers can be assembled by stacking up to 7 modules, in the
following sequence, starting from the top: red, yellow, orange, blue,
green and white. The sound module, if any, must always be positioned
at the top of the signal tower.
Technical characteristics
Maximum operational voltage: 250VAC/DC
Material: Polycarbonate or anodised aluminium
Connections: Screw clamp terminals, maximum
1.5mm2/16 AWG conductor section
Tightening torque: 0.5Nm/4.5lbin
Operating temperature: -20...+50°C
Number of stackable elements: Seven.
Degree of protection IEC/EN: IP65; IP54 for 8 LT7 S0B
.
Certifications and compliance
Certifications obtained: EAC, UL Listed, for USA and Canada (cULus file E318016) as Power Circuit and motor-mounted Apparatus - Stackable tower lights. Compliant with standards: IEC/EN 60947-5-1,
IEC/EN 60947-1, UL508, CSA C22.2 n° 14.
Additional Flashing Modules—include xenon bulbs
8LT7FLB3
Green flashing module 24VAC/DC
8LT7FLB4
Red flashing module 24VAC/DC
8LT7FLB5
Yellow flashing module 24VAC/DC
8LT7FLM3
Green flashing module 230VAC
8LT7FLM4
Red flashing module 230VAC
8LT7FLM5
Yellow flashing module 230VAC
Signal Tower Sounder Modules
LT7KIT-RYGB
8LT7S0B
24VAC/DC Pulsed 90dB
8LT7S2B
24VAC/DC Pulsed or Continuous 75dB
8LT7S2M
230VAC Pulsed or Continuous 75dB
Stand Alone Beacons
LB6KIT-O
LB6KIT-G
LB6KIT-R
LB6KIT-Y
LB6KIT-B
LB6KIT-W
LB6KIT-G
8LT7ALL...
1-11
ORANGE Lens 8LB6EL1 steady light module with BA15d lamp fitting,
direct supply with8LB6BP03 surface mount base.
GREEN Lens 8LB6EL3 steady light module with BA15d lamp fitting,
direct supply with8LB6BP03 surface mount base.
RED Lens 8LB6EL4 steady light module with BA15d lamp fitting, direct
supply with8LB6BP03 surface mount base.
YELLOW Lens 8LB6EL5 steady light module with BA15d lamp fitting,
direct supply with8LB6BP03 surface mount base.
BLUE Lens 8LB6EL5 steady light module with BA15d lamp fitting,
direct supply with8LB6BP03 surface mount base.
WHITE Lens 8LB6EL8 steady light module with BA15d lamp fitting,
direct supply with8LB6BP03 surface mount base.
Bulbs for Signal Tower and Beacons
General characteristics—Beacons
Signal beacons are fundamental elements in manufacturing processes
for the visual and audible signalling of the system status.
Technical characteristics
Maximum operational voltage: 250VAC/DC
8LT7ALB B
24VAC/DC 5W BA15d Incandescent bulb
Material: Polycarbonate
8LT7ALB M
230VAC 5W BA15d Incandescent bulb
Connections: Screw clamp terminals, maximum
1.5mm2/16 AWG conductor section
8LT7ALL B8
24VAC/DC LED BA15d bulb
Tightening torque: 0.5Nm/4.5lbin
8LT7ALL M8
230VAC LED BA15d bulb
Please note:
We have many other options for signal towers and beacons in our General Catalogue or
online at www.lovato.co.uk
Operating temperature: -20...+50°C
Degree of protection IEC/EN: IP54; IP30 if used with
8 LB6 BP 04, 8 LB6 BP 06 or 8 LB6 BP 08.
Certifications and compliance
Compliant with standards: IEC/EN 60947-5-1, IEC/EN 60947-1.
Switching
Power
Supplies
Order Code
Rated Output
Voltage
(V)
Output Power
(W)
Single Phase
General Characteristics
This type of equipment is used to power supply electromechanical and
electronic devices with DC control, such as contactors, time relays,
sensors, PLCs, DC motors, displays, SSRs and other equipment
normally found in automation systems and networks.
PSL1 005 24
0.21
5
Protections:
PSL1 010 24
0.42
10
PSL1 018 24
0.75
18
Short circuit, Overload, Input voltage peaks
Indications:
PSL1 030 24
1.25
30
PSL1 060 24
2.5
60
4.2
100
5
120
PSL1 240 24
10
240
PSL1 300 24
12.5
300
PSL1 480 24
20
480
4.2
100
PSL1 100 24
24VDC
PSL1 120 24
PSL1 030 24
PSL 1 060 24
Rated Output
Current
(A)
Two Phase
PSL2 100 24
PSL3 120 24
PSL3 480 24
LED indicator for power on
Operational Characteristics
Rated supply voltage:
100-240VAC for PSL1 005 24 - PSL1 100 24 types
115/230VAC self-configurable for PSL1 120 24… to
PSL1 480 24 types
400-500VAC for PSL2... and PSL3... ❶ types
Rated output voltage: 24VDC
Mains frequency: 50/60Hz
Output voltage adjustment by front potentiometer
24VDC
24VDC
PSL3 960 24
PFC function for types: PSL1 120 24 to PSL3 960 24
5
120 ❶
Parallel connection for types: PSL1 120 24, PSL1 240 24,
PSL1 300 24, PSL1 480 24, PSL2 100 24, PSL3 240 24,
PSL3 480 24, PSL3 960 24
10
240 ❶
High efficiency up to 92%
20
480 ❶
35mm DIN rail (IEC/EN 60715) mounting
40
960 ❶
Three Phase ❶
PSL3 240 24
LED indicator for low voltage conditions
Screw connection terminals
Plastic or metal housing depending on type
❶ Two-phase connection is admissable with a 25% output power derating.
IEC degree of protection: IP20 on terminals
PSL1 100 24
PSL1 120 24
Modular
Switching
Power
Supplies
Rated Output
Current
(A)
Output Power
PSL1M 010 12
0.83
10
PSL1M 024 12
2
24
2.75
33
PSL1M 054 12
4.5
54
PSL1M 072 12
6
72
PSL1M 010 24
0.42
10
PSL1M 024 24
1
24
1.5
36
PSL1M 060 24
2.5
60
PSL1M 100 24
4.2
100
Order Code
Rated Output
Voltage
(V)
(W)
Single Phase
PSL1M 033 12
12VDC
General Characteristics
Protections:
Short circuit, Overload, Input voltage peaks
Indications:
LED indicator for low voltage conditions
LED indicator for power on
Operational characteristics
Rated supply voltage: 100-240VAC
Rated output voltage: 12VDC for PSL1M...12 types;
24VDC for PSL1M...24 types
Mains frequency: 50/60Hz
PSL1M 036 24
PSL1M 010….
24VDC
Output voltage adjustment by front potentiometer
High efficiency up to 89%
35mm DIN rail (IEC/EN 60715) mounting
Screw connection terminals
Modular DIN 43880 housing; number of modules:
1 for PSL1M 010…
2 for PSL1M 024…
3 for PSL1M 033 12 and PSL1M 036 24
4 for PSL1M 054 12 and PSL1M 060 24
5 for PSL1M 072 12 and PSL1M 100 24
IEC degree of protection: IP20 on terminals
Certifications and compliance
Certifications obtained: GOST, UL Listed for USA and Canada (File
E318016) as Power Supplies in power circuit and motor-mounted
apparatus category.
Compliant with standards: IEC/EN 60950-1, IEC/EN 61000-6-2,
IEC/EN 61000-6-3, UL508, CSA C22.2 n° 14
PSL1M 033 12
PSL1M 036 24
1-12
Feed-Through
Terminal Blocks
CBD Series
CBD.2
Order Code
Rated
Cable Size
Current
Rating
Terminal
Pitch
(mm)
(A)
(mm)
Feed-Through Terminal Blocks
CBD.2
2.5
24
5.5
120
CBD.4
CBD.6
CBD.10
CBD.16
CBD.35
CBD.50
32
41
57
76
101
125
6.5
8
10
12
16
18
100
100
100
50
75
50
CBD.70
70
192
Ex(i) Blue Feed-Through Terminal Blocks
CBD.2EXI
2.5
24
CBD.4EXI
4
32
CBD.6EXI
6
41
CBD.10EXI
10
57
20.5
40
5.5
6.5
8
10
120
100
100
100
CBD.16EXI
16
76
12
CBD.35EXI
35
101
16
CBD.50EXI
50
125
18
CBD.70EXI
70
192
20.5
‘Big Box’ Bulk Packed Feed-Through Terminal Blocks
BB/CBD.2
2.5
24
5.5
BB/CBD.4
4
32
6.5
BB/CBD.6
6
41
8
BB/CBD.10
10
57
10
50
75
50
40
Order Code
4
6
10
16
35
50
To Suit Feed-Through Terminal Type
To Suit Terminal Type
Suitable for both 35mm ‘Top Hat’ and 32mm ‘G’ section rail
mounting
Superior effective current carrying capacity,
Very low contact resistance of the resulting connection
Ex (i) versions for use in ‘intrinsic safety’ circuits
Technical Characteristics
UL94V-0 polyamide insulating body
Available in standard beige (RAL 1001)
Operating temperature range: -40 ÷ +80 °C
Certifications and compliance
UL
CSA
KEMA - KEUR
BBJ-SEP
RINA
1400
1000
900
600
IEEE 323 (1E Qualification for Nuclear Power Plants)
Lloyds Register of Shipping
ENEL LV27/1
Pack
Quantity
50
25
25
25
25
10
CB.70/PT
CBD.70
CBR/PT
CBR.2
End Sections for Ex(i) Blue Feed-Through Terminals
CB.2/PTEXI
CBD.2
CB.6/PTEXI
CBD.4 & CBD.6
CB.10/PTEXI
CBD.10
CB.16/PTEXI
CBD.16
CB.35/PTEXI
CBD.35
CB.50/PTEXI
CBD.50
CB.70/PTEXI
CBD.70
Order Code
General Characteristics
CBD Series terminal blocks, within Cabur polyamide production, are the
basic series having feed-through function.
Reduced overall dimension
End Sections for Feed-Through Terminal Blocks
CB.2/PT
CBD.2
CB.6/PT
CBD.4 & CBD.6
CB.10/PT
CBD.10
CB.16/PT
CBD.16
CB.35/PT
CBD.35
CB.50/PT
CBD.50
CBD.35
Pack
Quantity
10
25
50
25
25
25
25
10
10
No of
Ways
Pack Qty
Pre-assembled Cross-connections
PM Pre-assembled Cross-connection
2-1
PM/20/2
CBD.2, TLD.2/GR
2
25
PM/20/3
CBD.2
3
25
PM/20/5
CBD.2
5
25
PM/20/10
CBD.2
10
10
PM/40/2
CBD.4,
2
25
PM/40/3
CBD.4
3
25
PM/40/5
CBD.4
5
25
PM/40/10
CBD.4
10
10
PM/60/2
CBD.6
2
25
PM/60/3
CBD.6
3
25
PM/60/5
CBD.6
5
25
PM/60/10
CBD.6
10
10
PM/41/2
DAS.4
2
25
PM/51/3
DAS.4
3
25
PM/51/5
PM/51/10
DAS.4
DAS.4
5
10
25
10
For the full range available visit: www.cabur.eu
CBD Series Assembly
Feed-Through
Terminal Blocks
CBC Series
Order Code
Rated
Cable
Size
Current
Rating
Terminal
Pitch
(mm)
(A)
(mm)
Pack
Quantity
CBC Series Feed-Through Terminal Blocks
2.5
24
5
120
CBC.4/GR
4
32
6
100
Patented ‘Easy-bridge’ cross-connection system
CBC.6/GR
6
41
8
100
Superior effective current carrying capacity
CBC.10/GR
10
57
10
100
Very low contact resistance of the resulting connection
CBC.16/GR
16
101*
12
50
Ex (i) versions for use in ‘intrinsic safety’ applications
CBC.35/GR
35
150**
16
50
Suitable for 35mm ‘Top Hat’ rail mounting only
Technical Characteristics
CBC.2 (Ex)i
2.5
24
5
120
CBC.4(Ex)i
4
32
6
100
UL94V-0 polyamide insulating body
CBC.6( Ex)i
6
41
8
100
1000V Rated to IEC 60947-7-1
CBC.10 (Ex)i
10
57
10
100
Available in standard grey (RAL 7042) or blue (Ex versions)
CBC.16 (Ex)i
16
101*
12
50
CBC.35 (Ex)i
35
150**
16
50
Certifications and compliance
CBC Series ‘Big Box’ Bulk-Packed Feed-Through Terminal Blocks
cURus
BB/CBC.2/GR
2.5
24
5
1400
KEMA - KEUR
BB/CBC.4/GR
4
32
6
1000
RINA
*101A when using 25sq mm conductor
**150A when using 50sq mm conductor
Order Code
UL(BR)
TERNA LV27/1
To Suit Feed-through Terminal Type
Pack
Quantity
End Sections for CBC Series Feed-Through Terminal Blocks
CBC.2-10/PT/GR
CBC.2/GR-CBC.10/GR
50
CBC.16/PT/GR
CBC.16/GR
25
CBC.35/PT/GR
CBC.35/GR
25
CBC.2 (Ex)i-CBC.10 (Ex)i
50
CBC.16/PT (Ex)i
CBC.16 (Ex)i
25
CBC.35/PT (Ex)i
CBC.35 (Ex)i
25
CBC.2-10/PT (Ex)i
Accessories for
Feed-Through
Terminal Blocks
CBC Series
Reduced overall dimension
CBC.2/GR
CBC Series Ex(i) Blue Feed-Through Terminal Blocks
CBC.2/GR
General Characteristics
CBC Series terminal blocks, with UL94V-0 polyamide insulating body,
feature enhanced design accuracy. Terminal blocks with different cross
-sections still guarantee visual uniformity within the completed rail
assembly.
To Suit
No of
Current
Pack
Terminal
Poles
Rating (A) Quantity
‘Easy Bridge’ Permanent Cross-connections for CBC Series
Order Code
PTC/2/10
CBC.2
10
24
10
PTC/4/10
CBC.4
10
32
10
PTC/6/10
CBC.6
10
41
10
PTC/10/10
CBC.10
10
57
10
POF/53
CBC.16
2
76
25
POF/06
CBC.35
2
125
15
ENEL DV27/1
ATEX Ex (e) & IEC (Ex) pending
General Characteristics
Patented ‘Easy-bridge’ cross-connection in 2, 3, 5, 10 or 50 pole
versions. Screwless, snap-in insertion with transversal and staggered
mode connection possibility. Once inserted, the resulting installation is
IPXXB protected without the need for further insulating covers.
Coloured Partition—Red
DFU/4/ROSSO
CBC.2/GR-CBC.35/GR
50
FOR END BRACKETS & TERMINAL MARKING SYSTEMS PLEASE
SEE PAGES 2-8 TO 2-10
EasyBridge Cross-connection
For the full range available visit: www.cabur.eu
2-2
Special Version
Terminal Blocks
Order Code
Rated
Cable
Size
Description
Pack
Qty
Feed-through on 2 or 3 levels
(mm)
Suitable for 35mm ‘Top Hat’ rail mounting
Two & Three Level Terminal Blocks
DBC.2/GR
2 Level Feed-Through - Grey 35mm ‘Top Hat’ mounting only
DAS.4
TLD.2
2.5
120
2 Level Feed-Through
4
120
3 Level Feed-Through
2.5
125
4
70
Fused Terminal Blocks
DBC.2/GR
SFR.4
Link Blade 5x20mm 6.3A Max
Order Code
Pack
Qty
To Suit Terminal Type
End Sections for Special Version Terminal Blocks
DBC/PT/GR
Grey for DBC.2/GR
25
DAS.4
25
Grey for TLD.2/GR
25
SFR.4
25
DAS/PT
TLD/PT/GR
SFR/PT
General Characteristics - Two & Three-Level Terminal Blocks
Two & three level terminal blocks, with Cabur polyamide insulating body
SFR.4/GR
Version for proximity sensors
Technical Characteristics
UL94V-0 polyamide insulating body
Available in standard beige RAL 1001 (or grey RAL 7042
where indicated)
Certifications and compliance
cURus / KEMA-KEUR / RINA/ Lloyds Register
General Characteristics - Fused Terminal Blocks
Fuseholder terminals, with Cabur polyamide insulating body
Available for 5x20mm or 6x32mm fuses
Suitable for both 35mm ‘Top Hat’ or 32mm ‘G’ rail mounting
Technical Characteristics
UL94V-0 polyamide insulating body
Available in standard beige RAL 1001 (or grey RAL 7042
where indicated)
Certifications and compliance
cURus / KEMA-KEUR / RINA / Lloyds Register
Earth Terminal Blocks
Order Code
Rated
Cable
Size
Description
Pack
Qty
Versions suitable for either 35mm ‘Top Hat’ or 32mm ‘G’ rail
mounting
(mm)
Earth Terminal Blocks
TEO.2
Earth for 35mm ‘Top Hat’ Rail
2.5
75
TEO.4
Earth for 35mm ‘Top Hat’ Rail
4
50
UL94V-0 polyamide insulating body
TE.6/O
Earth for 35mm ‘Top Hat’ Rail
6
45
Operating temperature range: -40 ÷ +80 °C
TE.10/O
Earth for 35mm ‘Top Hat’ Rail
10
35
TE.16/O
Earth for 35mm ‘Top Hat’ Rail
16
30
TE.50/O
Earth for 35mm ‘Top Hat’ Rail
50
15
To Suit Earth Terminal Type
Pack
Qty
End Sections for Earth Terminal Blocks
High Current
Terminal Blocks
Technical Characteristics
TEO.2
Order Code
TE.16/O
General Characteristics
Earth terminal blocks, with Cabur polyamide green/yellow insulating
body
cURus
KEMA-KEUR
RINA
ENEL LV27/7
CESI 02ATEX 061 U EEx e certificate
TEO.2/PT
TEO.2
50
TEO.4/PT
TEO.4
50
Order Code
Certifications and compliance
Rated Cable and Lug
Size
(mm)
Current
Rating
(A)
Pack Qty
General Characteristics
Power terminal blocks, with Cabur polyamide insulating body
Possibility to perform cross connections
GPM Series Insulated Studded Bar Power Feed Through Terminal Blocks
GPM.95/BB
95/M8
232
10
GPM.150/BB
150/M10
309
6
GPM.240/BB
240/M12
415
4
Suitable for both 35mm ‘Top Hat’ and 32mm ‘G’ rail mounting
Technical Characteristics
UL94V-0 polyamide insulating body
Operating temperature range: -40 ÷ +80 °C
Certifications and compliance
cULus pending / KEMA-KEUR / RINA
GPM.150/BB
Distribution Terminals
General Characteristics - Multi-pole Neutral/Earth Terminals
Order Code
No. of Poles
Terminal Size
Colour
Multi-pole Neutral / Earth Terminals
QBLOK.7/BLU
7
10mm
Blue
QBLOK.7/TE
7
10mm
Green
QBLOK.12/BLU
12
10mm
Blue
QBLOK.12/TE
12
10mm
Green
QBLOK.7/BLU
2-3
For the full range available visit: www.cabur.eu
Multipole Neutral or Earth terminals with 35mm Top Hat
Mounting
PA6 Insulating body
Marking Systems for
Terminal Blocks
Order Code
Marking & No. of Series
Tags/
Card
Universal Marking Tags
CNU/8/51
Blank
1x100
Blank Tag Marker Pen (Black)
1
CNU/8/510
Series 1-10 (10 tags of each no)
5x100
CNU/8/520
Series 11-20 (10 tags of each no)
5x100
CNU/8/530
Series 21-30 (10 tags of each no)
5x100
CNU/8/540
Series 31-40 (10 tags of each no)
5x100
CNU/8/550
Series 41-50 (10 tags of each no)
5x100
CNU/8/560
Series 51-60 (10 tags of each no)
5x100
CNU/8/570
Series 61-70 (10 tags of each no)
5x100
CNU/8/580
Series 71-80 (10 tags of each no)
5x100
CNU/8/590
Series 81-90 (10 tags of each no)
5x100
CNU/8/600
Series 91-100 (10 tags of each no)
5x100
CNU/8/L1
L1 (Full card of symbol)
5x100
CNU/8/L2
L2 (Full card of symbol)
5x100
CNU/8/L3
L3 (Full card of symbol)
5x100
CNU/8/U1
U1 (Full card of symbol)
5x100
CNU/8/U2
U2 (Full card of symbol)
5x100
CNU/8/V1
V1 (Full card of symbol)
5x100
CNU/8/V2
V2 (Full card of symbol)
5x100
CNU/8/W1
W1 (Full card of symbol)
5x100
CNU/8/W2
W2 (Full card of symbol)
5x100
CNU/8/PE
PE (Full card of symbol)
5x100
CB/CTL/NERO
Also Available
CNU/8/510
General Characteristics
Universal Marking Tags ideal for marking all types of Cabur Railmounted Terminal Blocks.
White polyamide with black printing
5mm standardised pitch and 8mm high
To be applied directly into position before or after
assembly of the terminal board
Many other marking options available visit:
www.cabur.eu
End Stops, Protection
Covers & Brackets
Order Code
Pack
Qty
Description
End Stops
BT/2
End stop for 15mm rail
25
BT/3
End stop for 35mm ‘Top Hat’ rail
25
BT/U
Universal end stop for 32/35mm rail
25
Protection Covers
BTU
PZM.4
PZM.6
Cover 64mm wide to suit CBD terminal
blocks up to 58mm depth inc din rail
Cover 85mm wide to suit CBD terminal
blocks over 58mm depth inc mounting rail
2m
2m
Supports for Protection Covers
PZD.4/SO
Support for PZM.4
20
PZD.6/SO
Support for PZM.6
10
Mounting Brackets for DIN Rail
PZM Cover + PZD Supports
ACI121213
Straight Mounting Bracket
20
ACI121314
Angled Mounting Bracket
20
General Characteristics - End Stops
End stops for Cabur rail-mounted terminal blocks
Available for 15mm ‘Top Hat’, 35mm ‘Top Hat’ and
32mm ‘G’ section rails
BT/U Universal version suits both 35mm ‘Top Hat’ and
32mm ‘G’ section rails
General Characteristics - Protection Covers
Protection Covers for Cabur terminal blocks
Protection against accidental contact or tampering
PZM covers for terminals up to 70mm capacity
PRP covers for safety protection of multiple crossconnections performed with PMP commoning bars
General Characteristics
DIN rail mounting brackets
‘CR6-Free’ RoHS Compliant
Choice of straight or inclined mounting
brackets to suit
ACI121314
We have presented in this catalogue only a few
of the faster moving items.
For the full catalogue download and technical
datasheets please visit www.cabur.eu using the
product search facility.
For the full range available visit: www.cabur.eu
2-4
Grey Standard Open
Slot Trunking
Order Code
Dimensions
Base
Height
(mm)
(metres)
Built-in wire retainer - double restricted slots on some sizes
17
120
Smooth fingers will not injure the installer or damage cables
30
96
Staggered mounting hole pattern for use in cabinets which
are designed to these standards.
CZE25*
40
72
CZE16
30
80
CZE13
40
60
60
40
CZE14
80
32
CZE34
100
24
CZE23
30
48
Self extinguishing rigid PVC Class 1 (UL94-VO)
CZE8
40
40
Colour: Grey - RAL7030
60
36
CZE15
80
24
CZE35
100
16
CZE24
30
32
CZE4
40
24
60
24
CZE11
80
24
CZE18
100
16
CZE26
40
24
60
24
80
24
CZE36
100
16
CZE27
40
16
CZE17
60
20
80
16
CZE37
100
16
CZE43
150
8
CZE28
40
16
60
16
80
16
CZE38
100
8
CZE30
60
12
80
12
100
8
60
8
80
8
100
8
CZE22*
CZE7
CZE5
CZE9
CZE6
CZE12
CZE19
Spare Trunking Lid
Order Code
To Suit Trunking
Base Width
(mm)
CZE10
CZE32
CZGCOP25
25
CZGCOP40
40
CZE33
CZGCOP60
60
CZE39
CZGCOP80
80
CZE31
CZGCOP100
100
CZE48
CZGCOP150
150
CZE40
15
25
40
60
80
100
120
150
200
*Note: Trunking with 4mm slots
3-1
General Characteristics
Wiring ducts with large fingers and larger slots for easy insertion of
larger wires and cables. Lead free.
(mm)
CZE20*
CZE Standard Slot Trunking
Pack Qty
Smooth wire entry allows for quick insertion of wires
Double scoreline allows easy removal of wall section or
individual fingers by hand without the use of tools
Non-slip cover with exclusive cover design with maximum
grip
RoHS Certified - Lead Free
Manufactured in 2m lengths
Technical Characteristics
Wire ducts with 8mm slots (4mm for CZE20, 22 & 25)
Certifications and compliance
A Norme EN50085-2-3
CSA
UR
RINA
CE marked
Trunking Lid
Covers for Standard and Narrow Slot Trunking.
Supplied in 2m lengths
Colour: Grey - RAL7030
RoHS Certified - Lead Free
Grey Narrow Open
Slot Trunking
Order Code
Dimensions
Pack Qty
General Characteristics
Designed for terminal block and Din component applications with higher
number of entries into the duct. Lead free.
Base
Height
(mm)
(mm)
(metres)
Built-in wire retainer - double restricted slots on some sizes
CZE164
30
80
Smooth fingers will not injure the installer or damage cables
CZE134
40
60
Staggered mounting hole pattern for use in cabinets which
are designed to these standards.
60
40
CZE144
80
32
CZE344
100
24
CZE84
40
40
CZE54
60
36
80
24
CZE354
100
16
Self extinguishing rigid PVC Class 1 (UL94-VO)
CZE44
40
24
Colour: Grey - RAL7030
60
24
80
24
CZE184
100
16
CZE264
40
24
RINA
To Suit Trunking
Base Width
(mm)
CZE64
60
24
CE marked
80
24
CZGCOP25
25
CZE364
100
16
CZGCOP40
40
CZE174
60
20
CZGCOP60
60
CZE194
80
16
CZGCOP80
80
CZE374
100
16
CZGCOP100
100
CZE104
60
16
CZGCOP150
150
80
16
CZE74
CZE..4 Narrow Slot Trunking
25
40
CZE154
CZE94
60
CZE114
Spare Trunking Lid
‘EDGE’ Trunking
80
CZE124
100
120
CZE324
Order Code
CZED110K60
Dimensions
(mm)
Pack Qty
(metres)
110 x 110 x 60
8
Double scoreline allows easy removal of wall section or
individual fingers by hand without the use of tools
Non-slip cover with exclusive cover design with maximum
grip
RoHS Certified - Lead Free
Manufactured in 2m lengths
Technical Characteristics
Wire ducts with 4mm slots
Certifications and compliance
A Norme EN50085-2-3
CSA
UR
Trunking Lid
Covers for Standard and Narrow Slot Trunking.
Supplied in 2m lengths
Colour: Grey - RAL7030
RoHS Certified - Lead Free
General Characteristics
EDGE angular slotted trunking with 4mm slots for electrical panels .
The Edge wire duct is designed to be used on the very corner of the
enclosure where the space is normally not utilized. This system allows
wires and cables to be routed professionally to the lateral panels.
One single size, 110 X 110 mm with 60 mm opening
Colour: Grey - RAL7030
Dimensions (mm)
RoHS Certified - Lead Free
Manufactured in 2m lengths
60
16
Certifications and compliance
60
A Norme EN50085-2-3
CSA
UR
CZED110K60
CE
110
Order Code
Smooth wire entry allows for quick insertion of wires
110
3-2
Halogen Free Open
Slot Trunking
Order Code
(mm)
(mm)
(metres)
EHF2525
25
84
EHF2537
37.5
64
50
52
EHF2575
75
32
EHF3737
37.5
48
50
32
EHF3775
75
32
EHF5050
50
24
75
24
Temperature class 113 (-25degC to +105degC)
50
24
Available in standard grey colour RAL7035
75
16
50
16
75
16
75
12
EHF5075
EHF7550
EHF7575
EHF10050
EHF10075
EHF12575
25
37.5
50
75
100
125
Order Code
Dimensions
Rail Vehicles: Underground Trains, High Speed Trains etc
Hostile environments such as: Nuclear reactors, Petrochemical plants, Offshore Oil Platforms
Military applications such as: Aircraft, Armoured vehicles,
Submarines, Ships
Technical Characteristics
UL94-VO
NFF2 (old VDE 0472 prt 815)
Manufactured in 2m lengths
Approvals & Certification
CE
General Characteristics
Available in grey colour RAL7030
Manufactured in 2m lengths
Base
Height
(mm)
(mm)
(metres)
25
84
A Norme EN50085-2-3
37.5
64
CSA
50
52
ED2575
75
32
ED3737
37.5
48
50
32
75
32
50
24
75
24
50
24
75
16
50
16
75
16
75
12
ED2537
ED2550
ED3750
25
37.5
ED3775
ED5050
ED5075
ED7550
ED7575
ED10050
ED10075
ED12575
3-3
Pack Qty
Public buildings with a high density of people such as:
Hotels, Cinemas, Theatres, Supermarkets, Offices, Banks
Self-extinguishing rigid PVC Class 1 (UL94-V0)
ED2525
ED DIN Size Open Slot Trunking
General Characteristics
Alofree wiring ducts are safe products: free from halogen additives, they
do not release toxic or corrosive gases and do not propagate flames as
the surface carbonisation prevents the material from catching fire, even
when in direct contact with the flames. They develop good resistance to
chemical and marine substances and have high insulating power. All
the corners in the open type trunking are rounded to prevent injury and
to avoid cuts in the cable insulation.
They are recommended for use in:
Height
EHF3750
DIN Size Open Slot
Trunking
Pack Qty
Base
EHF2550
EHF Halogen-free Open Slot Trunking
Dimensions
50
75
100
125
Approvals & Certification
CE
Flexible Open Slot
Ducting
Order Code
Dimensions
Base x Height
(mm)
Pack Qty
FLX10
12.5 x 12.5
25
FLX20
20 x 20
25
FLX30
30 x 30
25
FLX40
40 x 40
25
Description
Pack Qty
(metres)
General Characteristics
Self Adhesive flexible ducting
Self-extinguishing UL94-V2 Nylon
Temperature range -15degC to +80degC
Supplied in 500mm lengths
FLX - Flexible Open Slot Ducting
Trunking Accessories
Order Code
Marking Accessory
PTE
Label Holder
50
Cross-arm retainer
25
Description
Pack Qty
General Characteristics
PTE Label Holder for Labelling CZE/E4 Trunking
PTR Cross Arm Accessory used to retain cables when
trunking cover is removed. Adjustable along finger height to
retain large or small wire bundles. Can be cut down to suit
base width of trunking.
Cross Arm Accessory
PTE Label Holder
Cutting Tools
PTR
Order Code
General Characteristics
ETC120 cuts precise lengths of trunking
ETC120 will cut to a maximum size of 120 x 120mm
Bench Cutting Tool
ETC120*
Bench cutting tool
1
ETC120L
Spare blade for ETC120
1
Tool for punch-cutting sides of
trunking
1
Hand Held Cutting Tool
ECUT
ETC120*
Spiral Flexible Wrap
*Note: Colour may vary from picture shown
Order Code
Dimensions
Pack Qty
Dia (mm)
(metres)
CP3
3
50
CP6
6
25
CP10
10
25
CP12
12
25
CP14
14
20
CPN3
3
50
CPN6
6
25
CPN10
10
25
CPN12
12
25
CPA3
3
50
CPA6
6
25
CPA10
10
25
CPA12
12
25
Normal/Transparent
General Characteristics
Spiral flexible ducting for wire bundles
Manufactured in Polyethylene
Normal/Black
Self-extinguishing UL94-V2
CP Transparent Spiral Flexible Wrap
3-4
Open-type Panel
Transformers
TM Series
Order Code
Primary
Secondary
Dimensions
Voltage
(VAC)
Voltage
(VAC)
HxWxD
(mm)
30VA Rated
TM030.240.024
220/240
24
75 x 75 x 65
50VA Rated
TM050.240.024
TM050.240.110
220/240
220/240
24
110
TM050.415.024
TM050.415.110
TM050.415.240
100VA Rated
380/415
380/415
380/415
24
110
240
TM110.240.024
TM110.240.110
220/240
220/240
24
110
TM110.415.024
TM110.415.110
TM110.415.240
150VA Rated
380/415
380/415
380/415
24
110
240
TM115.240.024
TM115.240.110
TM115.415.024
TM115.415.110
TM115.415.240
220/240
220/240
380/415
380/415
380/415
24
110
24
110
240
220/240
220/240
380/415
380/415
380/415
24
110
24
110
240
220/240
24
220/240
380/415
380/415
380/415
110
24
110
240
220/240
220/240
380/415
380/415
380/415
24
110
24
110
240
120 x 122 x 115
220/240
220/240
380/415
380/415
380/415
24
110
24
110
240
120 x 122 x 135
200VA Rated
TM120.240.024
TM120.240.110
TM120.415.024
TM120.415.110
TM120.415.240
300VA Rated
TM130.240.024
TM130.240.110
TM130.415.024
TM130.415.110
TM130.415.240
400VA Rated
TM140.240.024
TM140.240.110
TM140.415.024
TM140.415.110
TM140.415.240
500VA Rated
TM150.240.024
TM150.240.110
TM150.415.024
TM150.415.110
TM150.415.240
750VA Rated
TM175.240.024
TM175.240.110
TM175.415.110
TM175.415.240
General Characteristics
Open-style single phase separation-type power transformers for
electrical panels
Simple wiring via large terminal block
Double-wound centre-tapped construction
Low loss laminations
Earth connection on frame
Available in sizes 30VA upto 2kVA
82 x 85 x 75
Technical Characteristics
Thermal insulation Class B
Insulation Voltage Primary/Secondary 3.5kV
Max Ambient Temp 40oC
Frequency 50/60Hz
82 x 85 x 95
Electrical protection Class I
Weights
105 x 100 x 95
105 x 100 x 105
30VA
1kg
50VA
1.5kg
100VA
2.3kg
150VA
2.7kg
200VA
3.2kg
300VA
4.2kg
400VA
5.8kg
500VA
7.8kg
750VA
9kg
Certifications and compliance
220/240
220/240
380/415
380/415
24
110
110
240
In accordance with EN61558-2-1
In accordance with CEI14-8
120 x 122 x 95
In accordance with IEC726
Wiring Diagram for TM Range
All standard transformers are voltage input 0-380-415V or
voltage input 0-220-240V
TRANSMINAL
Input Supply
FORMER TERBLOCK
Output Supply
W- - - - - - SCREEN TO BE CONNECTED TO EARTH
0
0
150 x 155 x 125
220
380
240
415
W
0
0
0
24
110
240
NOTES
Connect for:
a) 0-220-240V input, EITHER 220V OR 240V only
b) 0-380-415V input, EITHER 380V OR 415V only
Output of transformer is centre tapped
For 24V output connect between 0 and 24, for 110V output
connect between 0 and 110, for 240V output connect
between 0 and 240V
Earth screen to be connected to screw and nut on side of
transformer and to W terminal on transformer terminal block.
A cable from this connection to be connected to earth
4-1
Part-enclosed Panel
Transformers
Order Code
Primary
Voltage
(VAC)
Secondary
Voltage
(VAC)
TMCV30.400.24
TMCV30.400.48
TMCV30.400.110
230/400
230/400
230/400
12/24
24/48
55/110
TMCV30.400.230
50VA Rated
TMCV50.400.24
TMCV50.400.48
230/400
115/230
230/400
230/400
12/24
24/48
TMCV50.400.110
TMCV50.400.230
75VA Rated
TMCV75.400.24
230/400
230/400
55/110
115/230
230/400
12/24
TMCV75.400.48
TMCV75.400.110
230/400
230/400
24/48
55/110
TMCV75.400.230
100VA Rated
TMCV110.400.24
230/400
115/230
230/400
12/24
TMCV110.400.48
TMCV110.400.110
TMCV110.400.230
150VA Rated
TMCV115.400.24
TMCV115.400.48
TMCV115.400.110
TMCV115.400.230
200VA Rated
TMCV120.400.24
TMCV120.400.48
TMCV120.400.110
230/400
230/400
230/400
24/48
55/110
115/230
230/400
230/400
230/400
12/24
24/48
55/110
TMCV120.400.230
250VA Rated
TMCV125.400.24
TMCV125.400.48
TMCV125.400.110
TMCV125.400.230
300VA Rated
TMCV130.400.24
TMCV130.400.48
TMCV130.400.110
TMCV130.400.230
400VA Rated
TMCV140.400.24
TMCV140.400.48
TMCV140.400.110
TMCV140.400.230
500VA Rated
TMCV150.400.24
TMCV150.400.48
TMCV150.400.110
TMCV150.400.230
600VA Rated
TMCV160.400.24
TMCV160.400.48
TMCV160.400.110
TMCV160.400.230
230/400
Dimensions
HxWxD
(mm)
General Characteristics
Part-enclosed (IP20) single phase separation-type power transformers
for electrical panels
30VA Rated
TMCV Series
Simple wiring via integral terminal block
Dual input primary voltage (230/400V)
Low loss laminations
90 x 89 x 115
Available in sizes 30VA up to 600VA
DIN Rail Mountable up to 150VA
Technical Characteristics
100 x 89 x 115
Thermal insulation Class B
IP20 finger protection
Insulation Voltage Primary/Secondary 3.5kV
Max Ambient Temp 40oC
Frequency 50/60Hz
110 x 89 x 115
Electrical protection Class I
+/- 15V regulation tappings on primary
Weights
30VA
1kg
50VA
1.6kg
75VA
2kg
100VA
2.5kg
150VA
3.2kg
200VA
3.5kg
250VA
3.9kg
300VA
5kg
400VA
6.2kg
500VA
6.9kg
115/230
600VA
7.8kg
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
Certifications and compliance
140 x 101 x 125
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
132 x 125 x 145
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
142 x 125 x 145
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
152 x 125 x 145
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
230/400
230/400
230/400
230/400
12/24
24/48
55/110
115/230
120 x 89 x 115
120 x 101 x 125
130 x 101 x 125
In accordance with EN61558-2-2
Wiring Diagram for TMCV Range
All standard transformers are voltage input +15V 0 -15V 230V 400V
Input Supply
Output Supply
TRANSFORMER TERMINAL BLOCK
+15V
0
-15V
230
400
W
0
0
0
0
12
24
55
115
24
48
110
230
W- - - - - - SCREEN TO BE CONNECTED TO EARTH
NOTES
162 x 125 x 145
Connect for:
Input 0 - 230V connect 0 and 230V
Input 0 - 400V connect 0 and 400V
Input 0 - 245V connect +15V and 230V
Input 0 - 415V connect +15V and 400V
Input 0 - 215V connect -15V and 230V
Input 0 - 385V connect -15V and 400V
Output of transformer is centre tapped
For 24V Output connect between 0 and 24V
For 48V Output connect between 0 and 48V
For 110V Output connect between 0 and 110V
For 230V Output connect between 0 and 230V
W terminal is connected to the terminal block. A cable from
this connection to be connected to earth
The full power always refers to the maximum voltage
4-2
Notes
The products illustrated in this publication are subject to revision or improvement at any time. Catalogue descriptions, technical and operational data as well as other details herein specified do not have any contractual
value and must be considered only as an indication. The products must be installed and used only by qualified personnel in accordance with the relevant regulations in force for electrical installations and systems in
order to avoid damage or safety hazards. E.&E.O.
MOTOR
CONTROL
PROTECTION
CONTROL
AND
SIGNALLING
CIRCUIT
PROTECTION
ISOLATION
AUTOMATION
AND
CONTROL
ENERGY
MANAGEMENT
LOVATO ELECTRIC LTD
ENERGY AND AUTOMATION
LOVATO HOUSE
PROVIDENCE DRIVE
STOURBRIDGE
WEST MIDLANDS DY9 8HQ
TEL 08458 110023 or 01384 899700
FAX 08458 110024 or 01384 891654
Email
sales@lovato.co.uk