VISUAL SIGNALS Homeland Security Light Threat Level Status Indicator HSL Series FEATURES > PLC compatible The HSL Series Homeland Security Light is a stackable, multi- > Steady-on LED or incandescent light sources status visual signal whose five lens colors correspond to those > Molded-in gasketed lens modules of Homeland Security (DHS). > Lens colors correspond to colors used in the Homeland Security System This light will visibly communicate the current risk level issued by > Direct surface mount or pendant mount models > Optional multi-tone module in pendant base AGENCY APPROVALS > UL and cUL Listed used in the Homeland Security System devised by the Department the DHS by illuminating the appropriate corresponding color: green for low, blue for guarded, yellow for elevated, orange for high, and red for severe. Standard models are available with steady-on LED or incandescent light sources, which can be flashed through the use of a relay or PLC. Additionally, an optional multi-tone horn module in the base of the unit can provide audible notification. Custom units with flashing halogen, incandescent or strobe light sources are available on request. Designed to maximize the viewing surface while minimizing the mounting footprint, each lens incorporates a projection ring to > CE Marked > NEMA 4X and 3RRated project the light over a distance and diffusion optics for viewing efficiency at close range. All modules have captive gaskets and screws. Designed for use in NEMA 3R and 4X applications. > IP65 Rated Order Cat. No. 102MP-4, -10, or -15 for 4", 10" or 15" pipe mounting 3-66 D-04 extensions. For pipe mounting flange order Cat. No. 102PMF. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 1/2" (13mm) 1/2" (13mm) 18 1/8" (460mm) 18 1/8" (460mm) 22 3/4" (578mm) 19 7/8" (505mm) 4 1/8" (105mm) 1 1/4" (32mm) Cat. No. HSL-LED-N5 HSL-LED-G1 HSL-SIN-N5 HSL-SIN-G1 3" (76mm) 3" (76mm) Direct Surface Mount (Optional on request) Pendant Mount Lens Colors Light Source Electrical Rating Green, Blue, Yellow, Orange and Red Green, Blue, Yellow, Orange and Red Green, Blue, Yellow, Orange and Red Green, Blue, Yellow, Orange and Red Steady-on LED 120V 50/60 Hz Pendant mounting with tone capability Steady-on LED 24V DC Pendant mounting with tone capability Steady-on Incandescent 120V 50/60 Hz Pendant mounting with tone capability Steady-on Incandescent 24V DC Pendant mounting with tone capability Mounting D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-67 © Copyright 2004 Edwards VISUAL SIGNALS PathfinderTM Heavy Duty Rotating Light Twin Sealed Beams 100SB Series FEATURES > Twin sealed beams Edwards 100SB Series Pathfinder Rotating Beacons have powerful > Quiet Belt drive for simplified maintenance dual sealed beam lamps that rotate 360 degrees within a high impact polycarbonate dome. Polycarbonate domes are safer and easier to clean than glass domes and allow the transmission of more light than heavily colored glass. Polycarbonate domes are > PVC coated base also ideal for applications such as those required in food processing > "Search light" beam effect plants that prohibit the use of glass. SPECIFICATIONS The Edwards 100SB Series also features a PVC coated base that allows for greater corrosion resistance and durability than plastic or simple stamped metal bases. Wiring is routed through the 3/4" NPT hub on the bottom of the unit. The Pathfinder is conduit mounted. Available in five lens colors: red, amber, blue, green, and clear. > Two PAR36 / 35,000 candlepower bulbs > 80 flashes per minute > 900 hour long lamp life AGENCY APPROVALS 8 1/2" (216mm) > UL 1638 Listed > cUL Listed > NEMA Type 3R 9 1/2" (241mm) Dome Color Replacement Dome Electrical Rating Flash Rate Replacement Lamp Replacement Belt Peak Candlepower 100SBR-N5 100SBA-N5 100SBB-N5 100SBG-N5 100SBC-N5 Red Amber Blue Green Clear 100SB-LR 100SB-LA 100SB-LB 100SB-LG 100SB-LC 120V 60 Hz 0.8 Amp 80 FPM GE #4416-1 100SB-RB 35,000 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 w w w. e d w a r d s - s i g n a l s . c o m 3-59 © Copyright 2004 Edwards D-04 Cat. No. VISUAL SIGNALS AdaptaLight® Stackable Beacon PLC Compatible 101 Series FEATURES > PLC compatible The Edwards AdaptaLight Stackable Beacon is a unique audible- > Seven gasketed modules: steady-on or flashing incandescent steady-on or flashing halogen steady-on or flashing LED strobe > Stackable in any combination or color visual signaling device which can contain up to 5 light modules and a pulsating horn in a single “stack.” It is for heavy duty use in locations where visibility over longer distances is required. All modules are gasketed. The base of the AdaptaLight Stackable Beacon contains a pulsating horn rated at 85dB at 10 feet. The horn can be operated as a sixth independent signal or in conjunction with any one of the light modules. The steady-on modules provide a constant visual signal. They are > Base unit comes with 85 dB pulsating horn ideal for start/stop functions, on/off process or continuous duty visual signaling applications. > Vibration resistant heavy duty industrial design The flashing modules command immediate attention. They work well as a warning signal when used with the steady-on module. > Module rearrangement requires no wiring; screw terminals in base for field wiring Applications include signaling of equipment malfunction. > 300,000 peak candlepower strobe with the incandescent or LED light modules. The LED modules are > Electrical interconnection between units is through solid copper busses best for applications where long life (120,000 hours) is a requirement. AGENCY APPROVALS The strobe modules are ideal for high ambient light areas. It can effectively signal urgent status changes when used in conjunction The AdaptaLight can be surface or 1/2" (13mm) NPT conduit pipe mounted in non-hazardous dust and weatherproof applications. For indoor applications, it may be vertically mounted with lenses facing > UL 1638 Listed either up or down. For weatherproof installation, the unit must be > cUL Listed mounted vertically with lenses facing up. May also be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted, using the Cat. No. WBR, wall mount bracket. See 3-60 D-04 AdaptaBeacon Accessories page 3-118. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6" (152 mm) 3/4" (19 mm) 3 5/16" (100 mm) 3 5/8" (92 mm) 3 1/2" (89 mm) Module Type Voltage Nominal Current Flash Rate Replacement Horn Replacement Light Source Peak Candlepower Base Unit w/Horn with Horn (85 dB at 10 feet) 12V DC 24V DC 120V AC 50/60 Hz 0.05A (max) 0.05A (max) 0.05A (max) - 118-E1 118-G1 123A-N5 - - Flashing Incandescent Flashing Halogen Flashing Halogen 12V DC 24V DC 120V AC 50/60 Hz 1.0A 0.32A 0.11A 65 fpm 65 fpm 65 fpm - Industry Trade No. 94(1) 50LMP-9WH-D(2) 50LMP-12WH-D(3) 2374 653 879 Flashing LED Flashing LED 24V DC 120V AC 50/60 Hz 0.065A 0.025A 65 fpm 65 fpm - - color dependent 101SIN*-E1 Steady-on Incandescent 12V DC 101SINH*-G1 Steady-on Halogen 24V DC 101SINH*-N5 Steady-on Halogen 120V AC 50/60 Hz 1.0A 0.32A 0.11A - - Industry Trade No. 94(1) 50LMP-9WH-D(2) 50LMP-12WH-D(3) 2374 653 876 101SLED**-G1 101SLED**-N5 Cat. No. 101BS-E1 101BS-G1 101BS-N5 101FIN*-E1 101FINH*-G1 101FINH*-N5 101FLED**-G1 101FLED**-N5 Steady-on LED Steady-on LED 24V DC 120V AC 50/60 Hz 0.065A 0.025A - - - color dependent Strobe Strobe Strobe 12V DC 24V DC 120V AC 50/60 Hz 0.5A 0.3A 0.12A 65 fpm 65 fpm 65 fpm - 91B-ST(4) 91B-ST(4) 91B-ST(4) 300,000 300,000 300,000 101ST*-E1 101ST*-G1 101ST*-N5 *Insert lens color: R - red, A - amber, B - blue, G - green, M - magenta, C - clear **Insert lens and LED color: R - red, A - amber, B - blue, G - green (1) Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle is 1,520 hours. (2) Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle is 15,000 hours. Can also be replaced with Industry Trade No. 1692. (3) Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle is 25,000 hours. Can also be replaced with Industry Trade No. 15T7DC. (4) Strobe tube life at operating power to 75% efficiency is 3,000 hours. SIGNAL INPUT LOAD CHARACTERISTICS* Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 101BS-G1 101BS-N5 101FINH( )-G1 101FINH( )-N5 101SINH( )-G1 101SINH( )-N5 101FLED( )-G1 101FLED( )-N5 101SLED( )-G1 101SLED( )-N5 101ST( )-G1 101ST( )-N5 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 25 25 25 25 25 25 4 5 4 5 1.5 5 50 50 320 110 320 110 65 25 65 25 300 120 2/1 2/1 1.2/100 1.15/8 .36/1 .5/8 .07/1 .09/8 .07/1 .09/8 0.33/1 2.1/1 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-61 © Copyright 2004 Edwards D-04 Light Source Cat. No. VISUAL SIGNALS Triliptical® Stackable Status Indicator DeviceNetTM, PLC Compatible 102 Series FEATURES > PLC compatible The Edwards Triliptical Stackable Status Indicator is a unique > Seven interchangeable light source modules: steady-on or flashing incandescent steady-on or flashing halogen steady-on or flashing LED 300,000 peak candela strobe audible-visual signaling device that can contain up to 5 light modules and a pulsating horn in a single “stack.” All modules are gasketed. The Triliptical Stackable Status Indicator bases are available in three models. A shorter base for conduit or surface mounting or a larger base designed for use with an optional tone module assembly. The larger base is also available with an optional > Molded-in gasketed lens modules > Six lens colors available: red, amber/orange, yellow, blue, green & clear > Stackable in any combination or color > Base unit comes with optional tone module > Module rearrangement requires no wiring still projecting the light through use of a built-in projection ring. The lenses are available in six colors: red, amber/orange, yellow, blue, green, and clear. Each light source module contains a removable cover to allow for easy relamping. The light module cover features a molded-in gasket for dust tight reliability. Double optics and the triliptical design provides an increased viewing area without increasing the base diameter. The lens modules can be easily stacked together utilizing an internal retaining assembly. Two tone modules are available. A single tone module and a tone selectable tone module - one tone selectable from eight available tones. Provides up to 85 dB at 5 feet. The multi-tone module is also > UL 1638 Listed available with an optional DeviceNet interface that allows all eight > NEMA Type 3R, Type 4X and IP65 Rated D-04 The Triliptical diffusion optic lens allows viewing from close up while AGENCY APPROVALS > CE Marked low voltage directive and EMC directive 3-62 DeviceNet interface. tones to be controlled over a DeviceNet network. Surface or 3/4" (19mm) NPT conduit pipe mounting in nonhazardous dust and weatherproof applications. It is recommended that the unit be mounted vertically with lenses facing up. > cUL Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION DeviceNet Compatible Stackable Status Indicator DeviceNet network and all installed stacklight The 102 Series Triliptical Stackable Status Indicator standard open style (unsealed) 5 pin connector is has been tested by ODVA's authorized independent test lab and complies with ODVA conformance test used to connect the Stackable Beacon to the modules. The unisolated physical layer contains DeviceNet required mis-wiring protection circuitry. A DeviceNet bus. The current draw from the bus is 0.12A. The power required to drive the lamps is software. supplied separately from the bus power for the 120V The Triliptical DeviceNet Stackable Beacon is a slave AC (N5) version. DC power for the 24V DC (G1) device. It is a general purpose status indicator version may be taken locally or from the DeviceNet Network. A standard open style 2 pin connector is designed to indicate the status of a machine or process. The unit contains a preprogrammed microcontroller which implements the Group 2 used to connect 24V DC @ 1.6A or 120V AC at 0.6A to drive the 5 light sources. predefined Master/Slave Connection Set. This allows for one Explicit Messaging Connection and one Poll The DeviceNet compatible unit provides for complete Connection. The Stackable Beacon resets automatically when DeviceNet power is applied. light source diagnostics. Each light source: LED, The DeviceNet interface is in the Triliptical DeviceNet Base, 102TBS-DN, which interfaces between the light source is reported on the DeviceNet network. strobe, halogen or incandescent is continuously monitored for operability. An inoperable or missing SIGNAL INPUT LOAD CHARACTERISTICS* Light Source/Tone Module Cat. No. 102SIGST-G1 102SIGST-N5 102SIGMT-G1 102SIGMT-N5 102LS-SIN-G1 102LS-SIN-N5 102LS-SINH-G1 102LS-SINH-N5 102LS-FIN-G1 102LS-FIN-N5 102LS-FINH-G1 102LS-FINH-N5 102LS-ST-G1 102LS-ST-N5 102LS-SLED( )-G1 102LS-SLED( )-N5 102LS-FLED( )-G1 102LS-FLED( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 5 5 5 5 25 25 25 25 25 25 25 25 1.5 5 5 5 5 5 50 70 50 70 32 80 320 110 32 80 320 110 300 120 65 25 65 25 .24/.2 .35/.5 .24/.2 .35/.5 .36/1 .15/8 .36/1 .5/8 1.4/100 .3/8 1.2/100 1.15/8 .33/1 50/1 .025/1 .09/8 .07/1 .09/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-63 © Copyright 2004 Edwards D-04 102 Series continued on next page VISUAL SIGNALS Part # 023001 Cap TECHNICAL INFORMATION (supplied with 1/2" (13mm) Part # 023001 Cap (supplied with base module) /" (13mm) 12 base module) 121/8" (308mm) 151/2" (394mm) 35/8" (92mm) 125/8" (321mm) 35/8" (92mm) Signal Base (Cat. No. 102TBS) 35/8" (92mm) Signal Base (Cat. No. 102PMBS) Signal Base (Cat. No. 102DMBS) 11/4" (32mm) 13/4" (44mm) 41/8" (105mm) Part # 023001 Cap (supplied with base module) /" (13mm) 12 Gasket 3" (76mm) 3" (76mm) 3" (76)mm Catalog No. Description 3-64 D-04 102TBS-G1 Base Unit - Use with 102TBS-N5 optional horn assy 102DMBS-G1 Mini base for 102DMBS-N5 direct panel mount 102PMBS-G1 Mini base for 3/4" 102PMBS-N5 (19mm) conduit mt 102SIGST-G1 Optional Tone 102SIGST-N5 Module 102SIGMT-G1 102SIGMT-N5 102PMF Pipe Mount Flange 102MP-4 (4") Pipe Extensions (for use 102MP-10 (10") with Pipe Mount Flange) 102MP-15 (15") 102LM-* Lens Module 102LS-SINH-G1 Steady-on Halogen 102LS-SINH-N5 Light Source 102LS-SIN-G1 Steady-on Incandescent 102LS-SIN-N5 Light Source 102LS-FINH-G1 Flashing Halogen 102LS-FINH-N5 Light Source 102LS-FIN-G1 Flashing Incandescent 102LS-FIN-N5 Light Source 102LS-ST-G1 Strobe 102LS-ST-N5 Light Source 102LS-SLEDA-G1** Steady-on LED Light Source 102LS-SLED( ++ )-G1** 102LS-SLEDA-N5** ++ 102LS-SLED( )-N5** 102LS-FLEDA-G1** Flashing LED Light Source 102LS-FLED( ++ )-G1** 102LS-FLEDA-N5** 102LS-FLED( ++ )-N5** 102TBS-DN-G1 DeviceNet Base Unit 102TBS-DN-N5 102SIGMT-DN-G1 DeviceNet Base Mounted 102SIGMT-DN-N5 Optional Tone Module Electrical Ratings Lamp Ratings Replacement Lamp Lamp Life (hours) Calculated # Projected ## Manufacturer's Light Output 24V DC, 1.75A+ 120V AC, 0.60A+ 24V DC, 1.75A+ 120V AC, 0.60A+ 24V DC, 1.75A+ 120V AC, 0.60A+ 24V DC, 0.05A 120V AC, 0.05A 24V DC, 0.05A 120V AC, 0.05A N/A N/A N/A N/A N/A 24V DC, 0.32A 120V AC, 0.11A 24V DC, 0.32A 120V AC, 0.08A 24V DC, 0.32A 120V AC, 0.11A 24V DC, 0.32A 120V AC, 0.08A 24V DC, 0.30A 120V AC, 0.12A 24V DC 0.062A 120V AC 0.022A 24V DC 0.062A 120V AC 0.022A 24V DC, 1.75A+ 120V AC, 0.60A+ 24V DC, 0.05A 120V AC, 0.05A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 9 Watts 12 Watts 10 Watts 10 Watts 9 Watts 12 Watts 10 Watts 10 Watts 3 Joule 3 Joule — N/A N/A N/A N/A N/A 50LMP-9WH 50LMP-12WH Ind. Trade 303 50LMP-10W 50LMP-9WH 50LMP-12WH Ind. Trade 303 50LMP-10W N/A N/A N/A N/A N/A N/A N/A N/A 12,000 20,000 10,000 2,500 12,000 20,000 10,000 2,500 3,000 ### 3,000 ### 120,000 N/A N/A N/A N/A N/A — — — — 15,000 25,000 12,500 3,000 — — — — N/A 120,000 — — N/A 120,000 — — N/A 120,000 — N/A N/A N/A N/A N/A N/A N/A N/A N/A 653 peak candela 879 peak candela 829 peak candela 829 peak candela 653 peak candela 879 peak candela 829 peak candela 829 peak candela 300,000 peak candela 300,000 peak candela 4346 peak candela 1821 peak candela 4346 peak candela 1821 peak candela 4346 peak candela 1821 peak candela 4346 peak candela 1821 peak candela N/A N/A N/A N/A N/A N/A + Currents shown are for a stackable with 5 light modules. ++Signifies lens and LED color (B - blue, G - green, R - red or W - white) *Signifies lens module color (A - amber/orange, B - blue, C - clear, G - green, R - red, Y - yellow) **NOTE: LED light sources must be used with the corresponding color lens module (e.g., a blue LED light source, 102LS-SLEDB-G1, must be used with a blue lens, 102LM-B). # At nominal operating voltage. ##Projected lamp life based on manufacturer's calculated lamp life @ 65 fpm and 50% duty cycle. ###Strobe tube life @ operating power to 75% efficiency. 90 Fieldstone Court x Ph: 203.699.3300 x Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION How-to-order Triliptical Stacklites To build a Stacklite, one base unit and the required number of lens modules and light sources need to be ordered. For example, to build a 120VAC, two high, steady incandescent stacklight on a direct mount base, order (one) 102DMBS-N5, (two) 102LM (in required colors), and (two) 102LS-SIN-N5. Voltage ○○ ○○ ○○ ○○ ○○ DN** ○○ 102 ○○ ○○ ○○ ○○ = Use with optional tone module. Wiring terminals 3/4" (19mm) conduit mount* ○○ Options TBS ○○ ○○ — ○○ — Cat. No. ○○ Base Unit + ○○ 102 G1 = 24V DC N5 = 120V AC DMBS = Mini base for direct panel mount* PMBS = Mini base for 3/4" (19mm) conduit mount* *Cap included ** DN = Optional DeviceNet ○○ Options ○○ ○○ ○○ ○○ ○○ A= B= G= R= W= Amber Blue Green Red White ○○ ○○ ○○ ○○ ○○ ○○ G1 = 24V DC N5 = 120V AC ○○ Voltage ○○ Color (LED Only) ○○ ○○ ○○ ○○ ○○ ○○ ○○ SINH = Steady-on halogen FINH = Flashing halogen SIN = Steady-on standard incandescent FIN = Flashing standard incandescent ST = Strobe SLED = Steady-on LED FLED = Flashing LED ○○ ○○ Type ○○ C = Clear Y = Yellow — Light ○○ B = Blue R = Red + Cat. No. Light Source ○○ LS ○○ 102 ○○ LM = Lens module A = Amber/orange G = Green ○○ ○○ Lens Color 102 LS = G1 = 24V DC ○○ ○○ Cat. No. 102 ○○ ○○ ○○ ○○ ○○ ○○ DN** — ○○ LM ○○ + G1 = 24V DC N5 = 120V AC ○○ ○○ ○○ ○○ SIGST = Optional Single-Tone Module ○○ Light Sources — SIGMT = Optional Multi-Tone Module 102 Lens Modules — ○○ 102 ○○ Tone Module + ○○ 102 Pre-Assembled Three High Steady-On Incandescent Models The Triliptical Stackable Beacon is available pre-assembled 3 high stacks as shown in the below table. Colors Red, Green, Amber/Orange Red, Blue, Amber/Orange Red, Green, Amber/Orange Red, Blue, Amber/Orange Light Source Type Steady-On Incandescent Steady-On Incandescent Steady-On Incandescent Steady-On Incandescent 90 Fieldstone Court x Ph: 203.699.3300 x Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-65 © Copyright 2004 Edwards Voltage 24V DC 24V DC 120V AC 120V AC D-04 Catalog No. 102SIN-RGA-G1 102SIN-RBA-G1 102SIN-RGA-N5 102SIN-RBA-N5 VISUAL SIGNALS ChameleonTM LED Multi-Status Indicator PLC Compatible Type 4X 103 & 103I Series FEATURES > Weatherproof The Chameleon 103I Series** features an onboard processor with > 3 Visual Signals in One Compact Housing an internal jumper that allows the unit to function as either a steady > Multiple LED clusters in red, green and amber or red, blue and amber one or all three lights can be activated by either a PLC or contact closure. The first light activated will illuminate either steady or or flashing visual signal. The Chameleon is designed such that any flashing (set by an internal jumper). If a second light is activated, the Chameleon cycles between the two colors. A third activation > 120,000 hour light source life > 18 inch wire leads causes the Chameleon to cycle between all three colors: red, amber, and green or red, amber, and blue. > Immune to shock and vibration The Chameleon 103 Series has all the functionality of the 103I with the exception of the onboard processor and internal jumper. While AGENCY APPROVALS both series are PLC compatible, the 103 is designed such that all signal operation is controlled directly through a PLC's ladder logic > UL 1638 Listed rather than through the Chameleon's internal processor. > cUL Listed C22.2 No. 205 > UL Listed NEMA Type 4X Either Series Chameleon may be panel or conduit mounted. An integral double-threaded (internal/external) mounting nipple accommodates 3/4" (19mm) or 1/2" (13mm) conduit mounting. Edwards long life multi-status visual indicators are ideal for use where smaller lights are specified and multi status indication is re- 3-68 D-04 quired. **Patent Pending 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided for use when direct panel mounting) Locknut - 1.3625" O.D. (provided for use when direct panel mounting) Double threaded for panel mounting or 1/2" (13mm) conduit mounting Cat. No. 103I-RGA-G1 103-RGA-G1 103I-RGA-N5 103-RGA-N5 103I-RBA-G1 103-RBA-G1 103I-RBA-N5 103-RBA-N5 3 1/4" (82.6mm) LED Colors Replacement Lens Cat. No. Electrical Rating Lamp Life Lumen Ratings* Red Green Amber Red Green Amber Red Green Amber Red Green Amber Red Blue Amber Red Blue Amber Red Blue Amber Red Blue Amber 104-LC 24V DC 120,000 hr. 104-LC 24V DC 120,000 hr. 104-LC 120V 50/60 Hz 120,000 hr. 104-LC 120V 50/60 Hz 120,000 hr. 104-LC 24V DC 120,000 hr. 104-LC 24V DC 120,000 hr. 104-LC 120V 50/60 Hz 120,000 hr. 104-LC 120V 50/60 Hz 120,000 hr. 120 90 307 120 90 307 120 90 307 120 90 307 120 90 307 120 90 307 120 90 307 120 90 307 SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 5 65 0.070/8 120V AC 5 55 0.100/8 24V DC 5 55 0.070/8 120V AC 5 45 0.100/8 D-04 103-RBA-G1 103-RGA-G1 103-RBA-N5 103-RGA-N5 103I-RBA-G1 103I-RGA-G1 103I-RBA-N5 103I-RGA-N5 Operating Voltage *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-69 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Flashing LED & Halogen Lights PLC Compatible, Type 4X 104FINH & 104FLED Series FEATURES > NEMA Type 4X Enclosure > Panel or conduit mounting > 18 inch wire leads AGENCY APPROVALS > UL 1638 Listed > cUL Listed C22.2 No. 205 The Edwards 104FIN Series AdaptaBeacon flashing halogen lights and 104FLED Series AdaptaBeacon flashing LED lights are designed to provide a bright visual indication utilizing special optics within a shatter resistant polycarbonate lens mounted on a polycarbonate/ABS blend base. Suitable for indoor or outdoor installation. When mounted outdoors lens should be mounted facing up. May be panel mounted using the provided locknut or conduit mounted. An integral double threaded > CE Marked Low Voltage Directive and EMC Directive > UL Listed NEMA Type 4X (internal/external) mounting nipple accommodates 3/4" (19mm). Double (internal/external) threaded mounting nipple suitable for direct panel mounting or 1/2" (13 mm) conduit mounting. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a restricted area or an area of high danger. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Ideal for use where many multiple smaller flashing lights 3-70 D-04 are specified. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided for use when direct panel mounting) Locknut - 1.3625" O.D. (provided for use when direct panel mounting) Double threaded for panel mounting or 1/2" (13mm) conduit mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Light Source Ratings Electrical Ratings Replacement Lamp Cat. No. 104FINHA-G1 104FINHB-G1 104FINHC-G1 104FINHG-G1 104FINHR-G1 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 9 Watts 15,000 hr.*** 24V DC 0.77 Amps 653** 50LMP-9WH-D or industry trade no. 1692* (incandescent) 104FINHA-G5 104FINHB-G5 104FINHC-G5 104FINHG-G5 104FINHR-G5 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 9 Watts 15,000 hr.*** 24V 50/60 Hz 0.77 Amps 653** 50LMP-9WH-D or industry trade no. 1692* (incandescent) 104FINHA-N5 104FINHB-N5 104FINHC-N5 104FINHG-N5 104FINHR-N5 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 12 Watts 25,000 hr.*** 120V 50/60 Hz 0.25 Amps 879** 50LMP-12WH-D or industry trade no. 15T7DC* (incandescent) 104FLEDA-G1 104FLEDG-G1 104FLEDB-G1 104FLEDR-G1 Amber Green Blue Red 104-LA 104-LG 104-LB 104-LR 120,000 hr. 24V DC 0.065 A 38 lumens** 102 lumens** 35 lumens** 28 lumens** N/A 104FLEDA-N5 104FLEDG-N5 104FLEDB-N5 104FLEDR-N5 Amber Green Blue Red 104-LA 104-LG 104-LB 104-LR 120,000 hr. 120V 50/60 Hz 0.025 A 38 lumens** 102 lumens** 35 lumens** 28 lumens** Candlepower N/A *A non-halogen lamp as listed may be used in place of the halogen lamp. **Bulb manufacturer's rating. ***Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 24V DC 120V AC 25 25 4 5 320 250 65 25 1.2/100 1.15/8 .07/1 .09/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-71 © Copyright 2004 Edwards D-04 104FINH( )-G1 104FINH( )-N5 104FLED( )-G1 104FLED( )-N5 Operating Voltage VISUAL SIGNALS AdaptaBeacon® Steady LED & Halogen Lights PLC Compatible, Type 4X 104SINH & 104SLED Series FEATURES > NEMA Type 4X Enclosure > Panel or conduit mounting > 18 inch wire leads AGENCY APPROVALS > UL 1638 Listed > cUL Listed C22.2 No. 205 The Edwards 104SIN Series AdaptaBeacon steady halogen lights and 104SLED Series AdaptaBeacon steady LED lights are designed to provide a bright visual indication utilizing special optics within a shatter resistant polycarbonate lens mounted on a polycarbonate/ABS blend base. Suitable for indoor or outdoor installation. When mounted outdoors lens should be mounted facing up. May be panel mounted using the provided locknut or conduit mounted. An integral double threaded > CE Marked Low Voltage Directive and EMC Directive > UL Listed NEMA Type 4X (internal/external) mounting nipple accommodates 3/4" (19mm). Double (internal/external) threaded mounting nipple suitable for direct panel mounting or 1/2" (13 mm) conduit mounting. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a restricted area or an area of high danger. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Ideal for use where many multiple smaller flashing lights 3-72 are specified. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided for use when direct panel mounting) Locknut - 1.3625" O.D. (provided for use when direct panel mounting) Double threaded for panel mounting or 1/2" (13mm) conduit mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Light Source Ratings Electrical Ratings Replacement Lamp Cat. No. 104SINHA-G1 104SINHB-G1 104SINHC-G1 104SINHG-G1 104SINHR-G1 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 9 Watts 15,000 hr.*** 24V DC 0.77 Amps 653** 50LMP-9WH-D or industry trade no. 1692* (incandescent) 104SINHA-G5 104SINHB-G5 104SINHC-G5 104SINHG-G5 104SINHR-G5 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 9 Watts 15,000 hr.*** 24V 50/60 Hz 0.77 Amps 653** 50LMP-9WH-D or industry trade no. 1692* (incandescent) 104SINHA-N5 104SINHB-N5 104SINHC-N5 104SINHG-N5 104SINHR-N5 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 12 Watts 25,000 hr.*** 120V 50/60 Hz 0.25 Amps 879** 50LMP-12WH-D or industry trade no. 15T7DC* (incandescent) 104SLEDA-G1 104SLEDG-G1 104SLEDB-G1 104SLEDR-G1 Amber Green Blue Red 104-LA 104-LG 104-LB 104-LR 120,000 hr. 24V DC 0.065 A 38 lumens** 102 lumens** 35 lumens** 28 lumens** N/A 104SLEDA-N5 104SLEDG-N5 104SLEDB-N5 104SLEDR-N5 Amber Green Blue Red 104-LA 104-LG 104-LB 104-LR 120,000 hr. 120V 50/60 Hz 0.025 A 38 lumens** 102 lumens** 35 lumens** 28 lumens** Candlepower N/A *A non-halogen lamp as listed may be used in place of the halogen lamp. **Bulb manufacturer's rating. ***Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 104SINH( )-G1 104SINH( )-N5 104SLED( )-G1 104SLED( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 24V DC 120V AC 25 25 4 5 320 250 65 25 .36/1 .5/8 .07/1 .09/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-73 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Strobes PLC Compatible Type 4X 104ST Series FEATURES > NEMA Type 4X Enclosure > Panel or conduit mounted > 300,000 peak candela > 18 inch wire leads > Immune to shock and vibration The Edwards 104ST Series AdaptaBeacon strobes are designed for light duty applications in industrial, commercial and institutional applications where short term intermittent visual signaling is required. The strobe unit provides a bright indication utilizing special optics within a shatter resistant polycarbonate lens mounted on a polycarbonate/ABS blend base. Suitable for indoor or outdoor installation. When mounted outdoors AGENCY APPROVALS lens should be mounted facing up. May be panel mounted using the > UL 1638 Listed provided locknut or conduit mounted. > cUL Listed C22.2 No. 205 An integral double threaded (internal/external) mounting nipple > CE Marked Low Voltage Directive and EMC Directive accommodates 3/4" (19mm) or 1/2" (13 mm) conduit mounting. > UL Listed NEMA Type 4X where ear protection must be worn and audible signals may not be Edwards strobe lights are particularly effective in high noise areas heard or understood. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a restricted 3-74 D-04 area or an area of high danger. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided for use when direct panel mounting) Locknut - 1.3625" O.D. (provided for use when direct panel mounting) Double threaded for panel mounting or 1/2" (13mm) conduit mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Strobe Tube Peak Candlepower Electrical Ratings Replacement Lamp Cat. No. 104STA-N5 104STB-N5 104STC-N5 104STG-N5 104STR-N5 Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 3,000 hr* 300,000 120V 50/60 Hz 0.12 Amps 91B-ST *Calculated strobe tube life at operating power to 75% efficiency. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 104ST( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 120V AC 25 120 2.1/1 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-75 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Adverse Location Signal Type 4X, Marine Rated, Div. 2, UL 1971 Listed Model 105 Series FEATURES > Corrosion resistant > Six available light sources: - Steady-on incandescent - Steady-on LED cluster - Flashing incandescent - Flashing LED cluster - 300,000 peak candlepower - 800,000 peak candlepower, 8 joule high intensity strobe > Three mounting bases: - 3/4" (19mm) pipe mount attachment - Outlet box attachment - Wall mounting bracket AGENCY APPROVALS > UL 1638 and UL 1604 Listed The Edwards 105 Series are heavy duty beacons designed for use in industrial applications where a corrosion resistant Type 4X enclosure is required. The housing is manufactured from glassreinforced thermoplastic polyester resin and incorporates brass hardware. The double fresnel lens is made of polycarbonate. All light sources are supplied as UL listed component assemblies – ready to be attached to the selected mounting base. The Edwards 105DHISTC-FJ high intensity strobe is designed for use in compatible fire alarm system and other applications requiring electrical supervision of signaling circuit field wiring. All units can be mounted on 3/4" (19mm) NPT conduit using the 105PM attachment. The units can also be surface or wall mounted using the 105BX and 105BM attachments respectively. For indoor applications, may be vertically mounted with lenses facing up or down. For weatherproof installation, it is recommended that the unit be mounted with the lens facing up or with the lens horizontal. > UL Listed NEMA Type 4X enclosure > UL Listed Class I, Division 2, Groups A, B, C & D; Class II, Division 2, Groups F & G and Class III locations > cUL Listed C22.2 No. 205 > Marine UL 595 Listed, Category UXUB 3-76 D-04 > Marine UL 1598A Listed Cat No 105FINH mounted on a Cat No 105BM with the Cat No 105BX Cat. No. 105ST mounted on a Cat. No. 105BX Cat. No. 105HIST mounted on a Cat. No. 105BX Cat. No. 105HIST mounted on a Cat. No. 105PM > UL 1971 Listed Model 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 5/8" (92 mm) 3 5/8" (92 mm) Cat. No's. 105SLED 105FLED 105SINH 105FINH 105ST 4 3/8" (111 mm) 4 3/4" (121 mm) 4 5/8" (117 mm) 6 3/4" (171 mm) Cat. No's. 105HIST 105DHIST 4 1/2" (114 mm) 4 1/2" (114 mm) 5" (127 mm) 4 1/2" (114 mm) 4 1/2" (114 mm) 4 1/2" (114 mm) 2 1/4" (57 mm) 5 1/4" (133 mm) 6" (152 mm) Cat. No. 105BM Mounting Bracket (use with 105BX) Cat. No. 105BX Outlet Box Attachment Cat. No. 105PM Pipe Mount Attachment Module Ty p e Lamp Ratings Peak Candlepower V o ltage Current 105SLED*-G1 105SLED*-N5 Steady-On LED Steady-On LED 120,000 hours1,2 120,000 hours1,2 Color Dependent Color Dependent 24V DC 120V AC 0.062A 0.022A — 105FLED*-G1 105FLED*-N5 Flashing LED Flashing LED 100,000 hours1,2 100,000 hours1,2 Color Dependent Color Dependent 24V DC 120V AC 0.062A 0.022A — 105SINH**-G1 105SINH**-G5 Steady-On Halogen Steady-On Halogen 20W, 20,000 hours1,2 20W, 20,000 hours1,2 2839 2839 24V DC 24V AC 0.8A 0.8A 50LMP-20WH or Ind. Trade No. 1692 (Incandescent) 105SINH**-N5 Steady-On Halogen 25W, 20,000 hours1,2 2198 120V AC 0.2A 50LMP-25WH or Ind. Trade No. 25T8DC (Incandescent) 105FINH**-G1 105FINH**-G5 Flashing Halogen Flashing Halogen 20W, 20,000 hours1,2 20W, 20,000 hours1,2 2839 2839 24V DC 24V AC 0.8A 0.8A 50LMP-20WH or Ind. Trade No. 1692 (Incandescent) 105FINH**-N5 Flashing Halogen 25W, 20,000 hours1,2 2198 120V AC 0.2A 50LMP-25WH or Ind. Trade No. 25T8DC (Incandescent) 105ST**-G1 105ST**-N5 105ST**-R5 3 Joule Strobe 3 Joule Strobe 3 Joule Strobe 3,000 hours3 3,000 hours3 3,000 hours3 300,000 300,000 300,000 24V DC 120V AC 240V AC 0.3A 0.1A 0.02A 91B-ST 105DHISTC-FJ Fire Alarm (UL 1971) 8 Joule Strobe 3,000 hours3 26 cd wall (dome out) 24 cd wall (dome down) 26 cd ceiling 20-30V DC 1.08 - 0.83 A 92-ST 105DHIST***-FJ High Intensity 8 Joule Strobe 3,000 hours3 800,000 20-30V DC 1.08 - 0.83 A 92-ST 105HIST**-N5 High Intensity 8 Joule Strobe 3,000 hours3 800,000 120V AC 0.1A 92-ST 105HIST**-R5 High Intensity 8 Joule Strobe 3,000 hours3 800,000 240V AC 0.05A 92-ST 105HIST**-EK High Intensity 8 Joule Strobe 3,000 hours3 800,000 12-48V DC 0.05A 92-ST Cat. No. At nominal operating voltage. Projected lamp life based on manufacturer's calculated lamp life @ 65 fpm and 50% duty cycle. 3 Strobe tube life @ operating power to 75% efficiency. 2 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-77 © Copyright 2004 Edwards 1 D-04 *Lens and light source (LED) color: A - amber, B - blue, G - green, R - red. **Lens color: A - amber, B - blue, C - clear, G - green, M - magenta, R - red. ***Lens color: A - amber, B - blue, G - green, M - magenta, R - red Replacement Lamp VISUAL SIGNALS AdaptaBeacon® Explosionproof Rotating Lights Diode Polarized, Marine Rated 106DEX(†)RINH-GW Series FEATURES > Bracket, ceiling or pendant mount Edwards Explosionproof AdaptaBeacon Rotating Lights are > Diode polarized for use in electrically supervised circuits designed for installation in hazardous location environments. Rigid > High impact glass dome output and low maintenance. The units are UL Listed for Type 3R, Type 4X and marine installations. specifications and state-of-the-art technology provide for high visual > Dome guard (optional) > 20W halogen bulb Models are available for pendant, wall and ceiling mounting. May be mounted with the dome facing up or down. > 75 rotations per minute AGENCY APPROVALS > UL 1638 and 1203 Listed Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, off shore oil rigs, water and filtration plants, and chemical plants. > cUL Listed C22.2 No. 205 > NEMA Type 3R and Type 4X Rated > Marine UL 595 Listed Category UXUB > Marine UL 1598A Listed 3-78 D-04 > UL Listed Class I, Div. 1 & 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 13.88" (353mm) 4.03" (125mm) 12.38" (314mm) 4.50" (114mm) 5.95" (151mm) 13.15" (334mm) 13.00" 13.38" (330mm) (340mm) 13.75" (349mm) 13.53" (344mm) 7.80" (198mm) 7.80" (198mm) 7.80" (198mm) Lens Electrical Cat. No. Color Mounting Rating 106DEXBRINHR-GW Red Bracket 24 - 28V DC 106DEXBRINHA-GW Amber 0.8 Amp 106DEXBRINHB-GW Blue 106DEXBRINHG-GW Green 106DEXBRINHM-GW Magenta 106DEXBRINHC-GW Clear Replacement Inner Lens 59606065004 59606065001 59606065002 59606065003 59606065005 - Replacement Optional Dome Dome Guard EDCJGL175 EDCJGU15 Replacement Peak Bulb Candlepower 50LMP-20WH 2838 20W Halogen Bulb 25,000 hours* 106DEXCRINHR-GW Red 106DEXCRINHA-GW Amber 106DEXCRINHB-GW Blue 106DEXCRINHG-GW Green 106DEXCRINHM-GW Magenta 106DEXCRINHC-GW Clear Ceiling 24 - 28V DC 0.8 Amp 59606065004 59606065001 59606065002 59606065003 59606065005 - EDCJGL175 EDCJGU15 50LMP-20WH 20W Halogen Bulb 25,000 hours* 2838 106DEXPRINHR-GW Red 106DEXPRINHA-GW Amber 106DEXPRINHB-GW Blue 106DEXPRINHG-GW Green 106DEXPRINHM-GW Magenta 106DEXPRINHC-GW Clear Pendant 24 - 28V DC 0.8 Amp 59606065004 59606065001 59606065002 59606065003 59606065005 - EDCJGL175 EDCJGU15 50LMP-20WH 20W Halogen Bulb 25,000 hours* 2838 *Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle. HAZARDOUS LOCATION LISTINGS Class Group Ambient Temperature Operating Temperature Code 1 and 2 C,D 104F (40C) 131F (55C) 149F (65C) T6 (85C, 185F) T5 (100C, 212F) T4A (120C, 248F) I 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2B (260C, 500F) T2A (280C, 536F) T2A (280C, 536F) II 1 and 2 F,G II III 1 1 and 2 E 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-79 © Copyright 2004 Edwards D-04 Division I VISUAL SIGNALS AdaptaBeacon® Explosionproof Strobe Diode Polarized, NEMA Type 3R & 4X, UL 1971 Listed 106DEX(†)STC-FJ Series FEATURES > Bracket, Ceiling or Pendant Mount > Diode polarized for use in electronically supervised circuits > High impact glass dome > Dome guard (optional) > 65 flashes per minute Edwards Explosionproof AdaptaBeacon Strobe Lights are designed for installation in hazardous location environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. Powder coat epoxy finished gray. Each explosionproof strobe is UL Listed for Type 3R and Type 4X installations. The unit's contain a supervisory diode and four wire leads, for use in fire alarm applications. This strobe is also UL 1971 Listed (ADA) for indoor visual signaling applications for the hearing > For use in fire alarm systems impaired in non-sleeping areas. AGENCY APPROVALS Models are available for pendant, wall and ceiling mounting. May be > UL 1971 Listed for indoor visual signaling for the hearing impaired in non-sleeping areas > NEMA Type 3R & Type 4X Rated > Rated at 55 candela (wall) and 35 candela (ceiling) per UL 1971 mounted in any orientation. The Edwards 106DEX-FJ Hazardous Location Supervised AdaptaBeacon Strobe Light is designed for use in compatible fire alarm systems and other applications requiring electrical supervision of signaling circuit field wiring. 3-80 D-04 > UL Listed Class I, Div. 1 & 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 13.88" (353mm) 4.03" (125mm) 12.38" (314mm) 4.50" (114mm) 5.95" (151mm) 13.15" (334mm) 13.00" 13.38" (330mm) (340mm) 13.75" (349mm) 13.53" (344mm) 7.80" (198mm) 7.80" (198mm) 7.80" (198mm) Cat. No. 106DEXBSTC-FJ Lens Color Clear Mounting Bracket Electrical Rating 20 - 30V DC 1.4 Amp Replacement Dome EDCJGL175 Optional Dome Guard EDCJGU15 Replacement Strobe Tube 92-ST 3,000 hr* Peak Candlepower 800,000 106DEXCSTC-FJ Clear Ceiling 20 - 30V DC 1.4 Amp EDCJGL175 EDCJGU15 92-ST 3,000 hr* 800,000 106DEXPSTC-FJ Clear Pendant 20 - 30V DC 1.4 Amp EDCJGL175 EDCJGU15 92-ST 3,000 hr* 800,000 *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Division Group Ambient Temperature Operating Temperature Code I 1 C,D 104F (40C) 131F (55C) 149F (65C) T6 (85C, 185F) T6 (85C, 185F) T6 (85C, 185F) I 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2B (260C, 500F) T2A (280C, 536F) T2A (280C, 536F) II 1 E,F,G 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) II 2 F,G III 1 and 2 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-81 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Explosionproof Strobes Diode Polarized Marine Rated 106DEX(†)STM-FJ Series FEATURES > Bracket, Ceiling or Pendant Mount > Diode polarized for use in electronically supervised circuits > High impact glass dome > Dome guard (optional) > 65 flashes per minute A G E N C Y A P P R O VA L S > Marine Rated > NEMA Type 3R & Type 4X Rated 3-82 D-04 > UL Listed Class I, Div. 1 & 2 Edwards Explosionproof AdaptaBeacon Strobe Lights are designed for installation in hazardous location environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. Powder coat epoxy finished gray. Each explosionproof strobe is UL Listed for Type 3R and Type 4X installations. The unit's are marine rated, and contain a supervisory diode and four wire leads. Models are available for pendant, wall and ceiling mounting. May be mounted in any orientation. The Edwards 106DEXSTM-FJ Hazardous Location Supervised AdaptaBeacon Strobe Light is designed for use in applications requiring electrical supervision of signaling circuit field wiring. † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 13.88" (353mm) 4.03" (125mm) 12.38" (314mm) 4.50" (114mm) 5.95" (151mm) 13.15" (334mm) 13.00" 13.38" (330mm) (340mm) 13.75" (349mm) 13.53" (344mm) 7.80" (198mm) 7.80" (198mm) 7.80" (198mm) Lens Electrical Cat. No. Color Mounting Rating 106DEXBSTMR-FJ Red Bracket 20 - 30V DC 106DEXBSTMA-FJ Amber 1.08-0.83 Amps 106DEXBSTMB-FJ Blue 106DEXBSTMG-FJ Green 106DEXBSTMM-FJ Magenta 106DEXBSTMC-FJ Clear Replacement Dome EDCJGL175 Replacement Inner Lens P30191-1R P30191-1A P30191-1B P30191-1G P30191-1M P30191-1C Optional Dome Guard EDCJGU15 Replacement Strobe Tube 92-ST 3,000 hr* Peak Candlepower 800,000 106DEXCSTMR-FJ Red 106DEXCSTMA-FJ Amber 106DEXCSTMB-FJ Blue 106DEXCSTMG-FJ Green 106DEXCSTMM-FJ Magenta 106DEXCSTMC-FJ Clear Ceiling 20 - 30V DC 1.08-0.83 Amps EDCJGL175 P30191-1R P30191-1A P30191-1B P30191-1G P30191-1M P30191-1C EDCJGU15 92-ST 3,000 hr* 800,000 106DEXPSTMR-FJ Red 106DEXPSTMA-FJ Amber 106DEXPSTMB-FJ Blue 106DEXPSTMG-FJ Green 106DEXPSTMM-FJ Magenta 106DEXPSTMC-FJ Clear Pendant 20 - 30V DC 1.08-0.83 Amps EDCJGL175 P30191-1R P30191-1A P30191-1B P30191-1G P30191-1M P30191-1C EDCJGU15 92-ST 3,000 hr* 800,000 *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Group Ambient Temperature Operating Temperature Code 1 C,D 104F (40C) 131F (55C) 149F (65C) T6 (85C, 185F) T6 (85C, 185F) T6 (85C, 185F) I 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2B (260C, 500F) T2A (280C, 536F) T2A (280C, 536F) II 1 E,F,G 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) II 2 F,G III 1 and 2 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-83 © Copyright 2004 Edwards D-04 Division I VISUAL SIGNALS AdaptaBeacon® Explosionproof Rotating Lights Marine Rated 106EX(†)RIN Series FEATURES > Bracket, ceiling or pendant mount > High impact glass dome > Dome guard (optional) > 40W halogen bulb or 25W incandescent bulb > 75 rotations per minute AGENCY APPROVALS > UL 1638 and 1203 Listed > cUL Listed C22.2 No. 205 Edwards Explosionproof AdaptaBeacon Rotating Lights are designed for installation in hazardous location environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. The units are UL Listed for Type 3R, Type 4X and marine installations. Models are available for pendant, wall and ceiling mounting. May be mounted with the dome facing up or down. Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, off shore oil rigs, water and filtration plants, and chemical plants. > NEMA Type 3R & Type 4X Rated > Marine UL 595 Listed Category UXUB > Marine UL 1598A Listed 3-84 D-04 > UL Listed Class I, Div. 1 & 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 13.88" (353mm) 4.03" (125mm) 12.38" (314mm) 4.50" (114mm) 5.95" (151mm) 13.15" (334mm) 13.00" 13.38" (330mm) (340mm) 13.75" (349mm) 13.53" (344mm) 7.80" (198mm) 7.80" (198mm) 7.80" (198mm) Electrical Rating 120V 50/60 Hz 0.35 Amp Replacement Inner Lens*** See Note Replacement Dome EDCJGL175 Optional Dome Guard EDCJGU15 Replacement Bulb 50LMP-40WH 25,000 hrs.** Peak Candela 3,328 Bracket 240V 50/60 Hz 0.35 Amp See Note EDCJGL175 EDCJGU15 P-041917-0039 or 25T8/240V/DC/CL 120 hrs.** 2,914 106EXCRINH*-N5 Ceiling 120V 50/60 Hz 0.35 Amp See Note EDCJGL175 EDCJGU15 50LMP-40WH 25,000 hrs.** 3,328 106EXCRIN*-R5 Ceiling 240V 50/60 Hz 0.35 Amp See Note EDCJGL175 EDCJGU15 P-041917-0039 or 25T8/240V/DC/CL 120 hrs. ** 2,914 106EXPRINH*-N5 Pendant 120V 50/60 Hz 0.35 Amp See Note EDCJGL175 EDCJGU15 50LMP-40WH 25,000 hrs.** 3,328 106EXPRIN*-R5 Pendant 240V 50/60 Hz 0.35 Amp See Note EDCJGL175 EDCJGU15 P-041917-0039 or 25T8/240V/DC/CL 120 hrs.** 2,914 Cat. No. 106EXBRINH*-N5 Mounting Bracket 106EXBRIN*-R5 *Letter in this position denotes color of the beam: A - amber, B - blue, C - clear, G - green, R - red or M - magenta. ** Projected life based on manufacturer's calculated lamp life. *** Amber - 59606065001, Blue - 59606065002, Green - 59606065003, Red - 59606065004, Magenta - 59606065004 HAZARDOUS LOCATION LISTINGS Class Group Ambient Temperature Operating Temperature Code I 1 C,D 104F (40C) 131F (55C) 149F (65C) T6 (85C, 185F) T5 (100C, 212F) T4A (120C, 248F) I 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T1 (450C, 842F) T1 (450C, 842F) T1 (450C, 842F) II III 1 1 and 2 E,F,G 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-85 © Copyright 2004 Edwards D-04 Division VISUAL SIGNALS AdaptaBeacon® Explosionproof Strobes Marine Rated Models 106EX(†)ST Series FEATURES > Bracket, Ceiling or Pendant Mount Edwards Explosionproof AdaptaBeacon Strobe Lights are designed > High impact glass dome specifications and state-of-the-art technology provide for high visual > Dome guard (optional) output and low maintenance. > 65 flashes per minute The units are UL Listed for Type 3R and Type 4X installations. The AGENCY APPROVALS 120V AC, 240V AC and 250V DC models are Marine Rated. Models are available for pendant, wall and ceiling mounting. May be for installation in hazardous location environments. Rigid mounted in any orientation. > UL 1638 and 1203 Listed > cUL Listed C22.2 No. 205 Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage > NEMA Type 3R & Type 4X Rated treatment plants, off shore oil rigs, water and filtration plants, and > Marine UL 595 Listed Category UXUB (120V AC, 240V AC, and 250V DC models) chemical plants. > Marine UL 1598A Listed (120V AC, 240V AC, and 250V DC models) 3-86 D-04 > UL Listed Class I, Div. 1 & 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 13.88" (353mm) 4.03" (125mm) 12.38" (314mm) 4.50" (114mm) 5.95" (151mm) 13.15" (334mm) 13.00" 13.38" (330mm) (340mm) 13.75" (349mm) 13.53" (344mm) 7.80" (198mm) 7.80" (198mm) 7.80" (198mm) Replacement Dome EDCJGL175 Replacement Inner Lens P30191-1* Optional Dome Guard EDCJGU15 Replacement Strobe Tube 92-ST 3,000 hr.** Peak Candlepower 800,000 0.1A 0.05A 1.2A 0.1A EDCJGL175 P30191-1* EDCJGU15 92-ST 3,000 hr.** 800,000 0.1A 0.05A 1.2A 0.1A EDCJGL175 P30191-1* EDCJGU15 92-ST 3,000 hr.** 800,000 Cat. No. Mounting 106EXBST*-N5 Bracket 106EXBST*-R5 106EXBST*-EK 106EXBST*-S1 Voltage 120V 50/60 Hz 240V 50/60 Hz 12 - 48V DC 250V DC Current 0.1A 0.05A 1.2A 0.1A 106EXCST*-N5 106EXCST*-R5 106EXCST*-EK 106EXCST*-S1 Ceiling 120V 50/60 Hz 240V 50/60 Hz 12 - 48V DC 250V DC 106EXPST*-N5 106EXPST*-R5 106EXPST*-EK 106EXPST*-S1 Pendant 120V 50/60 Hz 240V 50/60 Hz 12 - 48V DC 250V DC *Letter in this position denotes color of the globe: A - amber, B - blue, C - clear, G - green, R - red or M - magenta. ** Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Division Group Ambient Temperature Operating Temperature Code I 1 C,D 104F (40C) 131F (55C) 149F (65C) T6 (85C, 185F) T6 (85C, 185F) T6 (85C, 185F) I 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2B (260C, 500F) T2A (280C, 536F) T2A (280C, 536F) II 2 F,G II III 1 1 and 2 E,F,G 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T4 (135C, 275F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-87 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Division 2 Strobes Diode Polarized NEMA Type 3R & 4 Rated 107DDV2(†)ST-G1 Series FEATURES > Bracket, ceiling or pendant mount Edwards AdaptaBeacon Strobe Lights are designed for installation > Diode polarized for use in electrically supervised circuits in Division 2 environments. Rigid specifications and state-of-the-art > High impact glass dome units are UL Listed for Type 3R and Type 4 installations. Models are available for pendant, wall and ceiling mounting. technology provide for high visual output and low maintenance. The > Dome guard (optional) > 65 flashes per minute AGENCY APPROVALS > UL 1638 and 1604 Listed Designed for hazardous location installation on 3/4" (19mm) conduit. May be mounted in any orientation. Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, water and filtration plants, and chemical plants. > cUL Listed C22.2 No. 205 > NEMA Type 3R & Type 4 Rated 3-88 D-04 > UL Listed Class I, Div. 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 10 1/2" (267mm) 4" (102mm) 9 3/4" (248mm) 11 3/8" (289mm) 9 7/8" (251mm) 10 1/8" (260mm) 10 7/8" (276mm) 10 1/4" (260mm) 7" (172mm) 7" (178mm) Cat. No. 107DDV2BSTR-G1 107DDV2BSTA-G1 107DDV2BSTB-G1 107DDV2BSTG-G1 107DDV2BSTM-G1 107DDV2BSTC-G1 Lens Color Mounting Red Bracket Amber Blue Green Magenta Clear Electrical Rating 24V DC 1.4 Amp Replacement Dome EDVPGL1HR Replacement Inner Lens 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC Optional Dome Guard EDVPGU1 Replacement Strobe Tube 92-ST 3,000 hr* Peak Candlepower 800,000 107DDV2CSTR-G1 107DDV2CSTA-G1 107DDV2CSTB-G1 107DDV2CSTG-G1 107DDV2CSTM-G1 107DDV2CSTC-G1 Red Amber Blue Green Magenta Clear Ceiling 24V DC 1.4 Amp EDVPGL1HR 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC EDVPGU1 92-ST 3,000 hr* 800,000 107DDV2PSTR-G1 107DDV2PSTA-G1 107DDV2PSTB-G1 107DDV2PSTG-G1 107DDV2PSTM-G1 107DDV2PSTC-G1 Red Amber Blue Green Magenta Clear Pendant 24V DC 1.4 Amp EDVPGL1HR 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC EDVPGU1 92-ST 3,000 hr* 800,000 *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class I II** III** Division Group Ambient Temperature Operating Temperature Code 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2 (300C, 572F) T1 (450C, 842F) T1 (450C, 842F) 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T3C (160C, 320F) 1 and 2** 1 and 2** 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-89 © Copyright 2004 Edwards D-04 **Pendant mount models only. Pendant mount models are also listed for use in Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G and Class III, Division 1 and 2 hazardous locations. VISUAL SIGNALS AdaptaBeacon® Division 2 Rotating Lights Marine Rated 107DV2(†)RINH Series FEATURES > Bracket, Ceiling or Pendant Mount Edwards AdaptaBeacon Rotating Lights are designed for installation > High impact glass dome technology provide for high visual output and low maintenance. > Dome guard (optional) The units are UL Listed for Type 3R, Type 4 and marine installations > 75 rotations per minute Models are available for pendant, wall and ceiling mounting. May be in Division 2 environments. Rigid specifications and state-of-the-art mounted with the dome facing up or down. AGENCY APPROVALS > UL 1638 and 1604 Listed > cUL Listed C22.2 No. 205 Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, water and filtration plants, and chemical plants. > NEMA Type 3R & Type 4 Rated > Marine UL 595 Listed Category UXUB > Marine UL 1598A Listed 3-90 D-04 > UL Listed Class I, Div. 2 † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 10 1/2" (267mm) 4" (102mm) 9 3/4" (248mm) 11 3/8" (289mm) 9 7/8" (251mm) 10 1/8" (260mm) 10 7/8" (276mm) 10 1/4" (260mm) 7" (172mm) 7" (178mm) Cat. No. 107DV2BRINH*-N5 Mounting Bracket 107DV2BRIN*-R5 107DV2CRINH*-N5 Bracket 107DV2CRIN*-R5 107DV2PRINHC-N5 (clear lens only) Pendant 107DV2PRINC-R5 (clear lens only) Electrical Rating 120V 50/60 Hz 0.35 Amp Replacement Dome *** Optional Dome Guard EDVPGU1 Replacement Lamp 50LMP-40WH 25,000 hr.** Peak Candlepower 3328 240V 50/60 Hz 0.1 Amp *** EDVPGU1 P-041917-0039 or Ind. Trade No. 25T8/240V/DC/CL 120 hr.** 2914 120V 50/60 Hz 0.35 Amp *** EDVPGU1 50LMP-40WH 25,000 hr.** 3328 240V 50/60 Hz 0.1 Amp *** EDVPGU1 P-041917-0039 or Ind. Trade No. 25T8/240V/DC/CL 120 hr.** 2914 120V 50/60 Hz 0.35 Amp EDVPGL1HR EDVPGU1 50LMP-40WH 25,000 hr.** 3328 240V 50/60 Hz 0.1 Amp EDVPGL1HR EDVPGU1 P-041917-0039 or Ind. Trade No. 25T8/240V/DC/CL 120 hr** 2914 *Letter in this position indicates lens color: R - red, A - amber, B - blue, G - green, M - magenta or C - clear **Projected life based on manufacturer's calculated lamp life. *** A - EDVPGL1AM, B - EDVPGL1BL, G - EDVPGL1GR, C - EDVPGL1HR, R - EDVPGL1RE HAZARDOUS LOCATION LISTINGS Class I II*** III*** Division Group Ambient Temperature Operating Temperature Code 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) 460C, 860F 475C, 887F 485C, 905F 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T3C (160C, 320F) 1 and 2*** 1 and 2*** ***Pendant mount models only. Pendant mount models are also listed for use in Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G and Class III, Division 1 and 2 hazardous locations. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-91 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Division 2 Strobes Marine Rated Models 107DV2(†)ST Series FEATURES > Bracket, Ceiling or Pendant Mount Edwards AdaptaBeacon Strobe Lights are designed for installation > High impact glass dome technology provide for high visual output and low maintenance. The > Dome guard (optional) units are UL Listed for Type 3R and Type 4 installations. The 120V AC, 240V AC and 250V DC models are Marine Rated. Models are > 65 flashes per minute available for pendant, wall and ceiling mounting. AGENCY APPROVALS Designed for bracket hazardous location installation on a 4" in Division 2 environments. Rigid specifications and state-of-the-art (102mm) square mounting box. May be mounted in any orientation. > UL 1638 and 1604 Listed > cUL Listed C22.2 No. 205 > NEMA Type 3R & Type 4 Rated Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, water and filtration plants, and chemical plants. > Marine UL 595 Listed Category UXUB (120V AC, 240V AC, 250V DC models) > Marine UL 1598A Listed (120V AC, 240V AC and 250V DC models) 3-92 D-04 > UL Listed Class I, Div. 2 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 10 1/2" (267mm) 4" (102mm) 9 3/4" (248mm) 11 3/8" (289mm) 9 7/8" (251mm) 10 1/8" (260mm) 10 7/8" (276mm) 10 1/4" (260mm) 7" (172mm) 7" (178mm) Cat. No. Mounting 107DV2BST*-N5 Bracket 107DV2BST*-R5 107DV2BST*-EK 107DV2BST*-S1 Electrical Rating 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC Current 0.1A 0.05A 1.2A 0.1A Replacement Dome EDVPGL1HR Replacement Inner Lens 96-L* Optional Dome Guard EDVPGU1 Replacement Strobe Tube 92-ST 3,000 hr. ** Peak Candlepower 800,000 107DV2CST*-N5 107DV2CST*-R5 107DV2CST*-EK 107DV2CST*-S1 Ceiling 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC 0.1A 0.05A 1.2A 0.1A EDVPGL1HR 96-L* EDVPGU1 92-ST 3,000 hr. ** 800,000 107DV2PST*-N5 107DV2PST*-R5 107DV2PST*-EK 107DV2PST*-S1 Pendant 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC 0.1A 0.05A 1.2A 0.1A EDVPGL1HR 96-L* EDVPGU1 92-ST 3,000 hr. ** 800,000 *Letter in this position denotes color of the globe: A - amber, B - blue, C - clear, G - green, R - red or M - magenta. **Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class I II*** III*** Division Group Ambient Temperature Operating Temperature Code 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2 (300C, 572F) T1 (450C, 842F) T1 (450C, 842F) 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T3C (160C, 320F) 1 and 2*** 1 and 2*** ***Pendant mount models only. Pendant mount models are also listed for use in Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G and Class III, Division 1 and 2 hazardous locations. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-93 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Division 2 Strobes Marine Rated Models 107DV2(†)ST Series FEATURES > Bracket, Ceiling or Pendant Mount > High impact glass dome > Dome guard (optional) > 65 flashes per minute AGENCY APPROVALS Edwards AdaptaBeacon Strobe Lights are designed for installation in Division 2 environments. Rigid specifications and state-of-the-art technology provide for high visual output and low maintenance. The units are UL Listed for Type 3R and Type 4 installations. The 120V AC, 240V AC and 250V DC models are Marine Rated. Models are available for pendant, wall and ceiling mounting. Designed for bracket hazardous location installation on a 4" (102mm) square mounting box. May be mounted in any orientation. > UL 1638 and 1604 Listed > cUL Listed C22.2 No. 205 > NEMA Type 3R & Type 4 Rated Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, water and filtration plants, and chemical plants. > Marine UL 595 Listed Category UXUB (120V AC, 240V AC, 250V DC models) 3-90 D-002 > Marine UL 1598A Listed (120V AC, 240V AC and 250V DC models) 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 www.edwards-signals.com © Copyright 2002 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 10 1/2" (267mm) 4" (102mm) 9 3/4" (248mm) 11 3/8" (289mm) 9 7/8" (251mm) 10 1/8" (260mm) 10 7/8" (276mm) 10 1/4" (260mm) 7" (172mm) 7" (178mm) Electrical Rating 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC Current 0.1A 0.05A 1.2A 0.1A Ceiling 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC Pendant 120V 60 Hz 240V 60 Hz 12 - 48V DC 250V DC Cat. No. 107DV2BST*-N5 107DV2BST*-R5 107DV2BST*-EK 107DV2BST*-S1 Mounting Bracket 107DV2CST*-N5 107DV2CST*-R5 107DV2CST*-EK 107DV2CST*-S1 107DV2PST*-N5 107DV2PST*-R5 107DV2PST*-EK 107DV2PST*-S1 Replacement Dome EDCJGL175 Optional Dome Guard EDCJGU15 Replacement Strobe Tube 92-ST 3,000 hr. ** Peak Candlepower 800,000 0.1A 0.05A 1.2A 0.1A EDCJGL175 EDCJGU15 92-ST 3,000 hr. ** 800,000 0.1A 0.05A 1.2A 0.1A EDCJGL175 EDCJGU15 92-ST 3,000 hr. ** 800,000 *Letter in this position denotes color of the globe: A - amber, B - blue, C - clear, G - green, R - red or M - magenta. **Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class I II*** III*** Division Group Ambient Temperature Operating Temperature Code 2 A,B,C,D 104F (40C) 131F (55C) 149F (65C) T2 (300C, 572F) T1 (450C, 842F) T1 (450C, 842F) 104F (40C) 131F (55C) 149F (65C) T4A (120C, 248F) T4 (135C, 275F) T3C (160C, 320F) 1 and 2*** 1 and 2*** ***Pendant mount models only. Pendant mount models are also listed for use in Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G and Class III, Division 1 and 2 hazardous locations. D-002 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 www.edwards-signals.com 3-91 © Copyright 2002 Edwards VISUAL SIGNALS Chameleon® Multi-Status Indicator PLC Compatible, DeviceNetTM 108 & 108-DN Series FEATURES > 120,000 hr. LED light sources > PLC compatible The Chameleon is designed to function as either a steady or flashing visual signal. It is designed such that any or all three lights > DeviceNet models available > 3 visual LED signals in one compact housing > Two stack capability for a fourth visual signal > Multi-tone base module option > Mutliple LED clusters in red, green and amber or red, blue and amber > Molded-in gasketed lens modules for dust tight reliability > Vibration resistant heavy duty industrial design > Mounting flange and 4", 10" and 15" mounting pipes available can be activated by a PLC or contact closure. The first light activated will illuminate either steady or flashing (set by an internal jumper). If a second light is activated, the Chameleon cycles between the two colors. A third activation causes the Chameleon to cycle between all three colors: red, amber, and green or red, amber, and blue. One additional lens module and light source – strobe, halogen, incandescent or LED – can be added for a fourth signal. The 108-DN Series Multi-Status Indicator utilizes the same DeviceNet interface as the 102 Series Triliptical Stacklight. It has been tested by ODVA's authorized independent test lab and complies with ODVA conformance test and software. The 108I Series features a multi-tone base module that allows the installer to select one of the following eight available tone options: stutter beep, continuous, 3 pulse horn, rapid siren, hi/lo, fast whoop, yeow and beep. The selected tone can be operated as an additional signal or used in conjunction with any of the visual signals. The signal is rated at 85 dB at 5 feet (1.63m). The 108-DN features the AGENCY APPROVALS > UL 1638 Listed same eight tones but allows all to be activated over the DeviceNet network. The 108 is also available without tone capability in direct surface and 2 inch (51mm) pipe mount bases. > NEMA Type 3R, Type 4X and IP65 Rated > cUL Listed C22.2 No. 205 3/4" (19mm) NPT conduit pipe mounting or surface mounting in non-hazardous dust and weatherproof applications. For indoor applications, may be vertically mounted with lenses facing up or down. For weatherproof installation, it is recommended 3-94 D-04 that the unit be conduit mounted vertically with lenses facing up. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 1 /2" (13mm) 1/2" (13mm) Part # 023001 Cap (supplied with base module) 1 / 2" (13mm) Part # 023001 Cap (supplied with base module) Part # 023001 Cap (supplied with base module) 35/8" (92mm) 73/4" (197mm) Signal Base (Cat. No. 102TBS) 35/8" (92mm) Signal Base (Cat. No. 102DMBS) 3 5 /8 " (137mm) 35/8" (92mm) Signal Base (Cat. No. 102PMBS) 57/8" (149mm) 41/8" (105mm) 13/4" (44mm) 11/4" (32mm) 3" (76mm) 3" (76)mm 3" (76mm) Cat. No. 108I Series & Cat. No. 108-DN Series Cat. No. 108IP Series Gasket Cat. No. 108ID Series LED Colors* Red, Green, Amber Red, Green, Amber Red, Blue, Amber Red, Blue, Amber Voltage 120V 50/60 Hz 24V DC 120V 50/60 Hz 24V DC Current .115A** .105A** .115A** .105A** Lumen Ratings* 120,90,307 120,90,307 120,90,307 120,90,307 Pipe mount (short base) Red, Green, Amber Red, Green, Amber Red, Blue, Amber Red, Blue, Amber 120V 50/60 Hz 24V DC 120V 50/60 Hz 24V DC .045A .055A .045A .055A 120,90,307 120,90,307 120,90,307 120,90,307 Direct mount Red, Green, Amber Red, Green, Amber Red, Blue, Amber Red, Blue, Amber 120V 50/60 Hz 24V DC 120V 50/60 Hz 24V DC .045A .055A .045A .055A 120,90,307 120,90,307 120,90,307 120,90,307 Red, Green, Amber Red, Green, Amber Red, Blue, Amber Red, Blue, Amber 120V 50/60 Hz 24V DC 120V 50/60 Hz 24V DC .115A** .105A** .115A** .105A** 120,90,307 120,90,307 120,90,307 120,90,307 Cat. No. 108I-RGA-N5 108I-RGA-G1 108I-RBA-N5 108I-RBA-G1 Mounting Pipe mount (w/tone module) 108IP-RGA-N5 108IP-RGA-G1 108IP-RBA-N5 108IP-RBA-G1 108ID-RGA-N5 108ID-RGA-G1 108ID-RBA-N5 108ID-RBA-G1 108-DN-RGA-N5 Pipe mount (w/tone module) 108-DN-RGA-G1 DeviceNet interface 108-DN-RBA-N5 108-DN-RBA-G1 *Manufacturer's lumen ratings listed in same order as LED colors. LED light sources have a lamp life of 120,000 hours. **Includes tone module SIGNAL INPUT LOAD CHARACTERISTICS* Light Source Cat. No. Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 108I-**-G1 108I-**-N5 108IP-**-G1 108IP-**-N5 108ID-**-G1 108ID-**-N5 24V DC 120V AC 24V DC 120V AC 24V DC 120V AC 5 5 5 5 5 5 .105 .115 .055 .045 .055 .045 0.24/0.2 0.35/0.2 0.07/0.2 0.10/8 0.07/0.2 0.10/8 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-95 © Copyright 2004 Edwards D-04 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. **Letters in this position signify the colors of the LED clusters: RGA - red, green and amber or RBA - red, blue and amber. VISUAL SIGNALS LED Star-BurstTM Multi-Status Indicator Three Output Modes Type 4X 109 Series FEATURES > Weatherproof Unparalleled visual brilliance utilizing state-of-the-art LED > PLC Compatible technology. The 109 Series LED Star-Burst is ideal for call for > Three Output Modes: Steady, 65 flashes per minute or rapid "burst" flash > 120,000 hour light source life > 18 inch wire leads assistance, process control and other applications that call for immediate attention. It functions as a dazzling steady-on LED light source that can be switched via a simple contact closure or PLC to either a standard (65 FPM) visual signal or a bursting, rapid flashing signal. The unit comes factory shipped to function as a steady signal that > Immune to shock and vibration no moving parts AGENCY APPROVALS can be switched to rapid flash. However, an internal jumper allows you to select a 65 FPM flash rate if desired. It may be panel or conduit mounted. > UL 1638 Listed An integral double-threaded (internal/external) mounting nipple accomodates 3/4" (19mm) or 1/2" (13mm) conduit mounting. See > cUL Listed C22.2 No. 205 Chameleon 103 Series for dimensional drawing. > UL Listed NEMA Type 4X Cat. No. LED Colors Replacement Lens Cat. No. Electrical Rating LED Life Lumen Ratings 109R-G1 109B-G1 109G-G1 109A-G1 Red Blue Green Amber 104-LR 104-LB 104-LG 104-LA 24V DC .42 A 120,000 hr. 50 22 40 50 109R-N5 109B-N5 109G-N5 109A-N5 Red Blue Green Amber 104-LR 104-LB 104-LG 104-LA 120V 50/60 Hz .42 A 120,000 hr. 50 22 40 50 3-96 D-04 SIGNAL INPUT LOAD CHARACTERISTICS* Light Source Cat. No. Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 109*-G1 109*-N5 24V DC 120V AC 5 5 65 55 0.070/8 0.100/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Screw Base Beacons & Strobes Weatherproof 110 Series FEATURES The Edwards 110 Series AdaptaBeacon flashing lights and strobes > Screw mount base provide a bright visual indication to signal warning of temporary hazards. They install easily into a standard light socket and are > Available in strobe and flashing incandescent suitable for indoor or outdoor temporary installation. They are particularly effective in high noise level areas, where ear > Lenses available in five colors: amber, blue, clear, green and red protection must be worn and audible signals may not be heard. They can advise personnel in manufacturing and industrial areas when an operation is starting or stopping or that they are entering a temporarily restricted area or an area of high danger. > Gasketed AGENCY APPROVALS > CE Marked 4" (102 mm) 5 1/2" (140 mm) Description Flashing Incandescent Replacement Lens 110-LR 110-LA 110-LB 110-LG 110-LC 110-LR 110-LA 110-LB 110-LG 110-LC Electrical Rating 120V 50/60 Hz 0.96 Amps Bulb Life 1,000 hr. Replacement Light Source Industry Standard No. 15T7DC 120V 50/60 Hz 0.03 Amps 3,500 hr. Replacement PC board assembly 110LS-ST-N5 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-97 © Copyright 2004 Edwards Strobe Lens Color Red Amber Blue Green Clear Red Amber Blue Green Clear D-04 Cat. No. 110FINR-N5 110FINA-N5 110FINB-N5 110FING-N5 110FINC-N5 110STR-N5 110STA-N5 110STB-N5 110STG-N5 110STC-N5 VISUAL SIGNALS AdaptaBeacon® Steady-on Incandescent & Fluorescent Lights Vaporproof 111 Series FEATURES > Pendant, ceiling or bracket mount The Edwards 111 Series beacons are vaporproof fixtures designed > Screw on glass globe in five colors for non-hazardous locations where the lamp, socket and wiring > Housing available in either black or silver gray dusts, moisture, non-explosive vapors and gases. The steady flourescent units utilize a 13 watt bulb (not included). The > Die Cast Aluminum Construction included). AGENCY APPROVALS Suitable for wet locations. Mount dome down for outdoor require protection from rain, corrosive fumes, non-combustible incandescent units utilize either a 100 watt or 150 watt bulb (not applications. > UL 1571 Listed The visual signals are available with a choice of five different globe colors: red, amber, blue, green or clear. The housing is available in either black or silver gray and all units are supplied with an 8 gauge wire guard. Three mounting options are available: ceiling, wall and 3-98 D-04 pendant. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 1/8" (181mm) 5 3/8" (137mm) 4 1/4" (108mm) 9 5/8" (244mm) 9 5/8" (244mm) 9" (229mm) 4 1/8" (105mm) 4 1/8" (105mm) Cat. No. Description 4 1/8" (105mm) Housing Color Replacement Globe Electrical Rating Max. Wattage 111SIN*-B 111SIN* Pendant Mount, with globe and guard Black Gray 111GL-* 120V 50/60 Hz 0.8 A (100 watt bulb) 1.25 A (150 watt bulb) 150 111SFL*-B 111SFL* Pendant Mount, with globe and guard 13W Clear Fluorescent Bulb (CFL Type, not included) Black Gray 111GL-* 120V 50/60 Hz 0.36 A 13 111SIN*-CM-B 111SIN*-CM Ceiling Mount with Surface Box, with globe and guard Black Gray 111GL-* 120V 50/60 Hz 0.8 A (100 watt bulb) 1.25 A (150 watt bulb) 150 111SFL*-CM-B 111SFL*-CM Ceiling Mount with Surface Box, with globe and guard 13W Clear Fluorescent Bulb (CFL Type, not included) Black Gray 111GL-* 120V 50/60 Hz 0.36 A 13 111SIN*-WM-B 111SIN*-WM Bracket Mount, with globe and guard Black Gray 111GL-* 120V 50/60 Hz 0.8 A (100 watt bulb) 1.25 A (150 watt bulb) 150 111SFL*-WM-B 111SFL*-WM Bracket Mount, with globe and guard 13W Clear Fluorescent Bulb (CFL Type, not included) Black Gray 111GL-* 120V 50/60 Hz 0.36 A 13 *Letter in this position signifies globe color: R - red, A - amber, B - blue, G - green, C - clear D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-99 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Division 2 Fluorescent Lights NEMA Type 3R 112DV2(†)FL-N5 Series FEATURES > Pendant, ceiling or bracket mount > High impact glass dome > Dome guard (included) > Two twin tube compact fluorescent lamps (not included) The Edwards 112 Series hazardous location AdaptaBeacon fluorescent lights are designed for installation in Division 2 environments. Two twin tube compact fluorescent lamps (not included) provide exceptional light output as well as energy efficiency and long life. Glass globes are internally fluted to provide complete dome volume "fill" and even light distribution. Globe exteriors are smooth to allow for easy cleaning. The units are UL AGENCY APPROVALS > UL 1570 and 844 Listed > CSA C22.2 No. 137 > NEMA Type 3R Rated Listed for Type 3R installations. Models are available for pendant, wall and ceiling mounting. Designed for hazardous location installation on 3/4" (19mm) conduit. Typical industrial and commercial applications include: food processing plants, refineries, mines, tankers, laboratories, sewage treatment plans, water and filtration plants, and chemical plants. 3-100 D-04 Use in locations where enclosed and gasketed signals are required. † Insert "B" for bracket, "C" for ceiling, or "P" for pendant mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6" (152mm) 9 7/8" (1251mm) 4 1/2" (114mm) 9" (229mm) 8 3/8" (213mm) 7 13/32" (188mm) 6" (152mm) 6" (152mm) Bracket Mount Ceiling Mount Cat. No. 112DV2BFLR-N5 112DV2BFLA-N5 112DV2BFLB-N5 112DV2BFLG-N5 112DV2BFLC-N5 Globe Color Red Amber Blue Green Clear 112DV2CFLR-N5 112DV2CFLA-N5 112DV2CFLB-N5 112DV2CFLG-N5 112DV2CFLC-N5 112DV2PFLR-N5 112DV2PFLA-N5 112DV2PFLB-N5 112DV2PFLG-N5 112DV2PFLC-N5 Pendant Mount Mounting Bracket Electrical Rating 120V 60 Hz Replacement Dome 112-GR 112-GA 112-GB 112-GG 112-GC Replacement Guard 112-Guard Red Amber Blue Green Clear Ceiling 120V 60 Hz 112-GR 112-GA 112-GB 112-GG 112-GC 112-Guard Red Amber Blue Green Clear Pendant 120V 60 Hz 112-GR 112-GA 112-GB 112-GG 112-GC 112-Guard HAZARDOUS LOCATION LISTINGS Class I Division Group Ambient Temperature Operating Temperature Code 2 A,B,C,D 104F (40C) T3B (75C, 167F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-101 © Copyright 2004 Edwards VISUAL SIGNALS Machlight ® Machine Status Indicator PLC Compatible 113 Series F E AT U R E S > PLC Compatible The Edwards Machlight Status Indicators are Pre-Assembled three > 3 High Pre-Assembled Units > Three lens colors: red, amber and green > Two Mounting Configurations: Surface or Pipe high stacklights designed to be used for machine and process control multi-status indication. Lens colors are arranged in the following top to bottom order: red, amber, and green. The Machlight is available in 24V AC/DC and 120VAC. There are two basic mounting models: surface and pipe mounting. The surface mount unit is supplied complete with mounting hardware. The pipe mount > Two Indication Options: Flashing or Steady version is supplied complete with a 10" (254mm) mounting pole with the hardware necessary to pole mount the light to a horizontal > 8 Inch (203mm) Wire Leads surface. The pipe mount version is also supplied with a side mount A G E N C Y A P P R O VA L S bracket that can be used to fix the light to the vertical side of a machine or control cabinet. > UL 508 Listed The Machlight utilizes a diffusion fresnel lens for increased viewing > cUL Listed area while maintaining a small, 2" (52mm) lens diameter. Lenses can be easily rearranged by removing the top retaining screw and simply sliding the lens assemblies off of the stack. SPECIFICATIONS > 24V AC/DC Model > 120V AC Model Edwards Machlights are particularly effective in high noise areas where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing 3-102 D-04 and process control areas when an operation is starting or stopping or to signal an equipment malfunction. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 2" (51mm) 2" (51mm) 10" (254mm) 10" (254mm) 9 1/2" (241mm) 3 1/8" (79mm) Surface Mount Pendant Mount Catalog No. Lens Colors* Electrical Ratings Lamp Ratings Replacement Lamp Lamp Life Light Source Mounting 113SP-RGA-AQ Red, Amber, Green 24V AC/DC, 0.24A 5 Watts Industry 301 500 hours Steady Pipe 113SP-RGA-N5 Red, Amber, Green 120V AC, 0.062A 10 Watts 113LMP-10W** 1,000 hours Steady Pipe 113FP-RGA-AQ Red, Amber, Green 24V AC/DC, 0.24A 5 Watts Industry 301 500 hours Flashing Pipe 113FP-RGA-N5 Red, Amber, Green 120V AC, 0.062A 10 Watts 113LMP-10W** 1,000 hours Flashing Pipe 113SS-RGA-AQ Red, Amber, Green 24V AC/DC, 0.24A 5 Watts Industry 301 500 hours Steady Surface 113SS-RGA-N5 Red, Amber, Green 120V AC, 0.062A 10 Watts 113LMP-10W** 1,000 hours Steady Surface 113FS-RGA-AQ Red, Amber, Green 24V AC/DC, 0.24A 5 Watts Industry 301 500 hours Flashing Surface 113FS-RGA-N5 Red, Amber, Green 120V AC, 0.062A 10 Watts 113LMP-10W** 1,000 hours Flashing Surface * Replacement Lens: Red - 113LR, Amber - 113-LA, Green - 113-LG, Blue is also available - 113-LB **The 113LMP-10W contains (3) individual bulbs. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 113SP-RGA-AQ 113SP-RGA-N5 113FP-RGA-AQ 113FP-RGA-N5 113SS-RGA-AQ 113SS-RGA-N5 113FS-RGA-AQ 113FS-RGA-N5 24V AC/DC 120V AC 24V AC/DC 120V AC 24V AC/DC 120V AC 24V AC/DC 120V AC 0.1 0.025 0.1 0.025 0.1 0.025 0.1 0.025 0.24 0.08 0.24 0.08 0.24 0.08 0.24 0.08 2.5/5 0.5/5 2.5/5 0.5/5 2.5/5 0.5/5 2.5/5 0.5/5 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-103 © Copyright 2004 Edwards VISUAL SIGNALS Compaxx TM Series Flashing Lights PLC Compatible Type 4X 114(†)FIN Series F E AT U R E S > NEMA Type 4X Enclosure The Edwards 114 Series Flashing incandescent lights are designed > Two Mounting Configurations Surface and Conduit for applications in industrial, commercial, and institutional applica- > 12 inch (305mm) wire leads 114 Series is ideal for process control as well as vehicular applications such as tow motors. > Black Impact Resistant Polycarbonate ABS Blend Base > Five Lens Colors tions where reliable and distinctive visual indication is required. The Suitable for indoor or outdoor installation. When mounted outdoors the unit should be mounted with the lens facing up. Two mounting configurations are available: > Available in Quantity Packaging (6) • The 114S, a surface mount version that utilizes a mounting A G E N C Y A P P R O VA L S gasket and locknut to provide a secure surface attachment and seal > UL 1638 Listed • The 114P, a pipe mount version for mounting on 1/2" (13mm) > cUL Listed NPT conduit. > UL Listed NEMA Type 4X Edwards flashing lights are particularly effective in high noise areas S P E C I F I C AT I O N S > 24V DC or 120V AC Operation where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing, process control and warehouse areas when an operation is starting or stopping or a vehicle is moving. They are also often used to signal equipment malfunction and to warn personnel that they are en- 3-108 D-04 tering restricted areas. † Insert "S" for surface mount, "P" for pipe mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided in the 114S for surface mounting) Locknut - 1.3625" O.D. (provided in the 114S for surface mounting) Internally threaded in the 114P for 1/2" (13mm)pipe mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Replacement Bulb Bulb Wattage Electrical Ratings 114SFINA-G1* 114SFINB-G1* 114SFINC-G1* 114SFING-G1* 114SFINR-G1* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 1692 15W 24V DC 0.610 Amps Surface Surface Surface Surface Surface 114SFINA-N5* 114SFINB-N5* 114SFINC-N5* 114SFING-N5* 114SFINR-N5* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 1692 15W 120V AC 0.150 Amps Surface Surface Surface Surface Surface 114PFINA-G1* 114PFINB-G1* 114PFINC-G1* 114PFING-G1* 114PFINR-G1* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 15T7DC 15W 24V DC 0.610 Amps 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 114PFINA-N5* 114PFINB-N5* 114PFINC-N5* 114PFING-N5* 114PFINR-N5* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 15T7DC 15W 120V AC 0.150 Amps 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe Mounting * For package quantities of 6 strobes add "-6" to the catalog number. e.g. 114SFING-G1-6 SIGNAL INPUT LOAD CHARACTERISTICS** Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge Current 114( )-G1 Series 24V DC 25 25 7A Exponentially Decaying 114( )-N5 Series 120V AC 25 25 0.8A Exponentially Decaying Cat. No. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-109 © Copyright 2004 Edwards D-04 **This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. VISUAL SIGNALS Compaxx TM Series Steady-on Lights PLC Compatible Type 4X 114(†)SIN Series F E AT U R E S > NEMA Type 4X Enclosure The Edwards 114 Series Steady-on incandescent lights are de- > Two Mounting Configurations Surface and Conduit signed for applications in industrial, commercial, and institutional > 12 inch (305mm) wire leads quired. The 114 Series is ideal for process control as well as vehicular applications such as tow motors. > Black Impact Resistant Polycarbonate ABS Blend Base > Five Lens Colors applications where reliable and distinctive visual indication is re- Suitable for indoor or outdoor installation. When mounted outdoors the unit should be mounted with the lens facing up. Two mounting configurations are available: > Available in Quantity Packaging (6) • The 114S, a surface mount version that utilizes a mounting A G E N C Y A P P R O VA L S gasket and locknut to provide a secure surface attachment and seal > UL 1638 Listed • The 114P, a pipe mount version for mounting on 1/2" (13mm) > cUL Listed NPT conduit. > UL Listed NEMA Type 4X Edwards steady-on lights are effective in high noise areas where S P E C I F I C AT I O N S > 24V DC or 120V AC Operation ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing, process control and warehouse areas when an operation is starting or stopping or a vehicle is moving. They are also often used to signal equipment malfunction and to warn personnel that they are entering 3-106 D-04 restricted areas. † Insert "S" for surface mount, "P" for pipe mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided in the 114S for surface mounting) Locknut - 1.3625" O.D. (provided in the 114S for surface mounting) Internally threaded in the 114P for 1/2" (13mm)pipe mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Replacement Bulb Bulb Wattage Electrical Ratings 114SSINA-G1* 114SSINB-G1* 114SSINC-G1* 114SSING-G1* 114SSINR-G1* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 1692 15W 24V DC 0.61 Amps Surface Surface Surface Surface Surface 114PSINA-G1* 114PSINB-G1* 114PSINC-G1* 114PSING-G1* 114PSINR-G1* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 1692 15W 24V DC 0.61 Amps 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 114SSINA-N5* 114SSINB-N5* 114SSINC-N5* 114SSING-N5* 114SSINR-N5* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 15T7DC 15W 120V AC 0.150 Amps Surface Surface Surface Surface Surface 114PSINA-N5* 114PSINB-N5* 114PSINC-N5* 114PSING-N5* 114PSINR-N5* Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR Industry Std. 15T7DC 15W 120V AC 0.150 Amps 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe Mounting * For package quantities of 6 strobes add "-6" to the catalog number. e.g. 114PSINB-N5-6 SIGNAL INPUT LOAD CHARACTERISTICS** Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Suge (inrush) 114( )-G1 Series 24V DC 25 25 7A Exponentially decaying 114( )-N5 Series 120V AC 25 25 0.8A Exponentially decaying Cat. No. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-107 © Copyright 2004 Edwards D-04 **This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. VISUAL SIGNALS Compaxx TM Series Strobes PLC Compatible Type 4X 114(†)ST Series F E AT U R E S > NEMA Type 4X Enclosure The Edwards 114 Series Strobes are designed for applications in > Two Mounting Configurations Surface and Conduit industrial, commercial, and institutional applications where reliable > 175,000 peak candela for process control as well as vehicular applications such as tow motors. The strobe units provide a bright visual indication by utiliz- > 12 inch (305mm) wire leads ing a linear strobe tube inside a shatter resistant polycarbonate > Black Impact Resistant Polycarbonate ABS Blend Base fresnel lens. > Five Lens Colors the unit should be mounted with the lens facing up. Two mounting > Available in Quantity Packaging (6) configurations are available: and distinctive visual indication is required. The 114 Series is ideal Suitable for indoor or outdoor installation. When mounted outdoors • The 114S, a surface mount version that utilizes a mounting A G E N C Y A P P R O VA L S > UL 1638 Listed > cUL Listed gasket and locknut to provide a secure surface attachment and seal • The 114P, a pipe mount version for mounting on 1/2" (13mm) > UL Listed NEMA Type 4X S P E C I F I C AT I O N S > Replaceable Linear Strobe Tube Powered at 1.75 Joules > 12 to 48 VDC Operation NPT conduit. Edwards strobe lights are particularly effective in high noise areas where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing, process control and warehouse areas when an operation is starting or stopping or a vehicle is moving. They are also often used to signal equipment malfunction and to warn personnel that they are en- 3-104 D-04 tering restricted areas. † Insert "S" for surface mount, "P" for pipe mount 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 7/8" (98.4mm) Gasket (provided in the 114S for surface mounting) Locknut - 1.3625" O.D. (provided in the 114S for surface mounting) Internally threaded in the 114P for 1/2" (13mm)pipe mounting 3 1/4" (82.6mm) Cat. No. Lens Color Replacement Lens Cat. No. Strobe Tube Peak Candlepower Electrical Ratings 114SSTA-EK** 114SSTB-EK** 114SSTC-EK** 114SSTG-EK** 114SSTR-EK** Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 114-ST 1,500 hr* 175,000 24V DC 0.350 Amps Surface Surface Surface Surface Surface 114PSTA-EK** 114PSTB-EK** 114PSTC-EK** 114PSTG-EK** 114PSTR-EK** Amber Blue Clear Green Red 104-LA 104-LB 104-LC 104-LG 104-LR 114-ST 1,500 hr* 175,000 24V DC 0.350 Amps 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe 1/2" NPT Pipe Mounting *Calculated strobe tube life at operating power to 75% efficiency. ** For package quantities of 6 strobes add "-6" to the catalog number. e.g. 114SSTA-EK-6 SIGNAL INPUT LOAD CHARACTERISTICS*** Cat. No. 114 Series Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 7 350 .45/.02 ***This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-105 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Industrial Truck Strobe Twist-On Lens, Multi-Voltage 3000SD-EK Series FEATURES > 1.5 Joule Strobe The 3000SD-EK Series AdaptaBeacon visual signals are surface, > 12-48V DC flange mount strobes designed for industrial applications and for > 80 Nominal Single Flashes per minute > Six lens colors: red, amber, blue, green, magenta and clear > Flange mount applications where warning on a moving vehicle such as a fork lift or tow motor is required. The light flashes at 80 nominal single flashes per minute. The strobe is rated at 1.5 Joules. The unit draws exceptionally low current for a 12-48 V DC unit. The twist on-off lens makes for easy strobe tube and/or lens replacement. The 3000SD-EK also features > 18" wire leads a fully gasketed lens for environmental integrity. > Low current draw 3 1/2" (89 mm) > 150,000 peak candlepower 3 1/2" (89 mm) 5" (127 mm) 3-116 D-04 Cat. No. 3000SDR-EK 3000SDA-EK 3000SDB-EK 3000SDG-EK 3000SDC-EK Electrical Ratings 12V DC 0.275 Amps 90 Fieldstone Court | Ph: 203.699.3300 | 24V DC 0.130 Amps Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 48V DC 0.130 Amps Lens Color Replacement Lens Replacement Strobe Tube Red Amber Blue Green Clear 3000SD-LR 3000SD-LA 3000SD-LB 3000SD-LG 3000SD-LC 91B-ST © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Industrial Worklight Twist-On Lens 4000 FEATURES The Edwards AdaptatBeacon Industrial Worklight is a high intensity industrial lantern made from high impact poycarbonate with a heavy-duty aluminum and wooden handle. The wooden handle is long enough to allow easy use even while wearing heavy work gloves. The unit features a mounting stand that articulates 180° to allow the light's beam to be horizontally or vertically directed in 22 1/2° > Polished parabolic reflector > Articulating steel mounting stand > Heavy duty wood handle > Clear prismatic lens > Replacement bulb PRI3 increments. The mounting stand is nickle plated cold-rolled steel. The unit operates off a standard 6V lantern battery. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-117 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Flashing Incandescent Lights PLC Compatible NEMA Type 4X 48FIN Series FEATURES > Weatherproof The Edwards 48 Series AdaptaBeacon flashing lights incorporate a > 25W Halogen lamp in 120V AC Model; 20W Halogen lamp in 24V AC and 24V DC Models > Snap-on high impact polycarbonate/ABS base unique double fresnel lens that has been optically engineered to maximize brilliance. This is accomplished with a series of complementing fresnels that cause the dome to "fill" when the light is operating. Beam distance is also increased with fresnel lenses. The incandescent lights are available in six colors: red, amber, blue, green, magenta, and clear. > Shatter resistant polycarbonate lens AGENCY APPROVALS > UL 1638 Listed > UL Listed NEMA Type 4X enclosure Designed for indoor or outdoor installation. May be direct or 1/2" (13mm) conduit mounted. For weatherproof installation, units must be mounted vertically with the lens facing up. Use Cat. No. GSKKIT gasket kit for weatherproof surface installation of AC models. May be corner mounted indoors using the Cat. No. CBR, corner mount bracket, or wall mounted indoors using the Cat. No. WBR, wall mount bracket. See Adaptabeacon Accessories, page 3-118. > cUL Listed Edwards flashing lights are particularly effective in high noise level areas, especially where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a restricted area or an area of high danger. May be used where a smaller light output is desired or where many multiple smaller flashing lights are specified. The gasketed NEMA 4X enclosure ensures installation acceptability in most industrial and commercial 3-2 D-04 locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 4 7/32" (108mm) Use Cat. No. GSK-KIT gasket kit for weatherproof surface mount installation on AC units 1/2" (13 mm) conduit hole 4 9/32" (109mm) Lens Color Replacement Lens Lamp Ratings Replacement Flasher Electrical Ratings Replacement Lamp 48FINR-N5-25WH 48FINA-N5-25WH 48FINB-N5-25WH 48FING-N5-25WH 48FINM-N5-25WH 48FINC-N5-25WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 25 watts 175 Lumens* 2198 candlepower 25,000 hr.** P-041917-0026 120V 50/60 Hz 0.20 Amps 50LMP-25WH or Ind. Trade No. 25T8DC 48FINR-G5-20WH 48FINA-G5-20WH 48FINB-G5-20WH 48FING-G5-20WH 48FINM-G5-20WH 48FINC-G5-20WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LR 20 Watts 226 Lumens* 2839 candlepower 25,000 hr.** P-041917-0029 24V 50/60 Hz 0.80 Amps 50LMP-20WH or Ind. Trade No. 1692 48FINR-E1 48FINA-E1 48FINB-E1 48FING-E1 48FINM-E1 48FINC-E1 Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 13 watts 189 Lumens* 2374 candlepower 1,520 hr.** P-041917-0028 12V DC 1.0 Amps Ind. Trade No. 94 48FINR-G1-20WH 48FINA-G1-20WH 48FINB-G1-20WH 48FING-G1-20WH 48FINM-G1-20WH 48FINC-G1-20WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 20 watts 226 Lumens* 2839 candlepower 25,000 hr.** P-041917-0029 24V DC 0.80 Amps 50LMP-20WH or Ind. Trade No. 1692 Cat. No. *Bulb manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 48FIN( )-G1-20WH 48FIN( )-N5-25WH Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 25 25 800 200 2.2/100 1.3/8 D-04 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-3 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® LED Flashing Light PLC Compatible NEMA Type 4X 48FLED Series FEATURES > Weatherproof The Edwards 48FLED Series AdaptaBeacon LED flashing lights > Multiple LED cluster reflected from double parabolic inner reflector > 120,000 hour light source life incorporate a unique double fresnel lens that has been optically engineered to maximize brilliance. This is accomplished with a series of complementing fresnels that cause the dome to “fill” when the light is operating. Beam distance is also increased with fresnel lenses. Light emitting diode lights are immune to shock and > Immune to shock and vibration vibration. The AdaptaBeacon LED clusters are internally oriented to > Snap-on high impact polycarbonate/ABS base allow viewing when the unit is mounted either horizontally or vertically. The lights are available in four colors: red, amber, blue > Shatter resistant polycarbonate lens AGENCY APPROVALS > UL 1638 Listed > UL Listed NEMA Type 4X enclosure > cUL Listed and green. Designed for indoor or outdoor installation. May be direct, conduit, or box mounted on a 4" (102mm) octagon box on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations mount units vertically with dome up. Use Cat. No. GSK-KIT gasket kit for weatherproof surface installation of AC models. May be mounted indoors using the Cat. No. CBR corner mount bracket, or Cat. No. WBR wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Edwards long life flashing LED beacons are particularly effective in high noise level areas, especially where ear protection must be worn and a visual status indicator is required. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a restricted area or an area of high danger. May be used where a smaller light output is desired or where many multiple smaller flashing lights are specified. The gasketed NEMA 3-4 D-04 Type 4X enclosure ensures installation acceptability in most industrial and commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION Use Cat. No. GSK-KIT gasket kit for weatherproof surface mount installation on AC units 4 7/32" (108mm) 1/2" (13 mm) conduit hole 4 9/32" (109mm) Cat. No. Lens Color Replacement Lens Electrical Ratings LED Ratings Lamp Life 48FLEDA-G1 48FLEDB-G1 48FLEDG-G1 48FLEDR-G1 48FLEDA-N5 48FLEDB-N5 48FLEDG-N5 48FLEDR-N5 Amber Blue Green Red Amber Blue Green Red 96-LA 96-LB 96-LG 96-LR 96-LA 96-LB 96-LG 96-LR 24V DC 0.065A 38 lumens 35 lumens 102 lumens 28 lumens 38 lumens 35 lumens 102 lumens 28 lumens 120,000 hr. 120V 50/60 Hz 0.025A 120,000 hr. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 48FLED( )-G1 48FLED( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 4 5 65 25 .07/1 .09/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-5 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® SteadyOn Incandescent Light PLC Compatible NEMA Type 4X 48SIN Series FEATURES > Weatherproof The Edwards 48SIN Series AdaptaBeacon steady-on lights are > 25W Halogen lamp in 120V AC Model; 20W Halogen lamp in 24V AC and 24V DC Models > Snap-on high impact polycarbonate/ABS base designed to meet continuous visual signaling requirements. The unique double fresnel lens has been optically engineered to maximize brilliance. This is accomplished with a series of complementing fresnels that cause the dome to “fill” when the light is operating. Beam distance is also increased with fresnel lenses. And, with no moving parts, the lights are immune to shock and > Shatter resistant polycarbonate lens AGENCY APPROVALS > UL 1638 Listed > UL Listed NEMA Type 4X enclosure > cUL Listed vibration. The incandescent lights are available in six colors: red, amber, blue, green, magenta, and clear. Designed for indoor or outdoor installation. The lights may be direct or 1/2" (13mm) conduit mounted on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. Use Cat. No. GSK-KIT gasket kit for weatherproof surface installation of AC models. May be corner mounted indoors using the Cat. No. CBR, corner mount bracket, or wall mounted indoors using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Ideally suited for applications where a continuous steady-on incandescent light signal is required or where ambient noise makes audible signals difficult to hear. The 48SIN is used where multiple, smaller, stand-alone visual signals are required. The gasketed NEMA 4X enclosure ensures installation acceptability in most 3-6 D-04 industrial and commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 4 7/32" (108mm) Use Cat. No. GSK-KIT gasket kit for weatherproof surface mount installation on AC units 1/2" (13 mm) conduit hole 4 9/32" (109mm) Light Source Cat. No. Lens Color Replacement Lens Lamp Ratings Electrical Ratings Replacement Lamp 48SINR-N5-25WH 48SINA-N5-25WH 48SINB-N5-25WH 48SING-N5-25WH 48SINM-N5-25WH 48SINC-N5-25WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 25 Watts 175 Lumens* 2198 candlepower 20,000 hr.** 120V 50/60 Hz 0.20 Amps 50LMP-25WH or Industry Trade No. 25T8DC 48SINR-G5-20WH 48SINA-G5-20WH 48SINB-G5-20WH 48SING-G5-20WH 48SINM-G5-20WH 48SINC-G5-20WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 20 Watts 226 Lumens* 2839 candlepower 20,000 hr.** 24V 50/60 Hz .80 Amps 50LMP-20WH or Industry Trade No. 1692 48SINR-E1 48SINA-E1 48SINB-E1 48SING-E1 48SINM-E1 48SINC-E1 Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 15 Watts 189 Lumens* 2374 candlepower 1,520 hr.** 12V DC 1.0 Amps Industry Trade No. 94 48SINR-G1-20WH 48SINA-G1-20WH 48SINB-G1-20WH 48SING-G1-20WH 48SINM-G1-20WH 48SINC-G1-20WH Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 20 Watts 226 Lumens* 2839 candlepower 20,000 hr.** 24V DC .80 Amps 50LMP-20WH or Industry Trade No. 1692 *Bulb manufacturer's Lumen rating. **Projected lamp life based on manufacturer's calculated lamp life at 65 fpm and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 48SIN( )-G1-20WH 48SIN( )-N5-25WH Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 25 25 800 200 .9/1 .8/8 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-7 © Copyright 2004 Edwards D-04 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. VISUAL SIGNALS AdaptaBeacon® Steady-On LED Lights PLC Compatible NEMA Type 4X 48SLED Series FEATURES > Weatherproof The Edwards 48SLED Series AdaptaBeacon LED steady-on lights > Multiple LED cluster reflected from double parabolic inner reflector > 120,000 hour light source life are designed to meet continuous visual signal requirements. The unique double fresnel lens that has been optically engineered to maximize brilliance. This is accomplished with a series of complementing fresnels that cause the dome to “fill” when the light is operating. Beam distance is also increased with fresnel lenses. > Immune to shock and vibration Light emitting diode lights are immune to shock and vibration. The > Snap-on high impact polycarbonate/ABS base AdaptaBeacon LED clusters are internally oriented to allow viewing when the unit is mounted either horizontally or vertically. The lights > Shatter resistant polycarbonate lens AGENCY APPROVALS > UL 1638 Listed > UL Listed NEMA Type 4X enclosure > cUL Listed are available in four colors: red, amber, blue and green. Designed for indoor or outdoor installation. May be direct, conduit, or box mounted on a 4" (102mm) octagon box on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations the units must be mounted vertically with dome up. Use Cat. No. GSK-KIT gasket kit for weatherproof surface installation of AC models. May be corner mounted indoors using the Cat. No. CBR, corner mount bracket, or wall mounted indoors using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Edwards long life steady-on LED beacons are ideally suited for applications where a continuous steady-on status indicator is required and where ambient noise makes audible signals difficult to hear. The 48SLED is ideal where multiple, smaller, stand-alone visual signals are required. The gasketed NEMA 4X enclosure ensures installation acceptability in most industrial and commercial 3-8 D-04 locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 4 7/32" (108mm) Use Cat. No. GSK-KIT gasket kit for weatherproof surface mount installation on AC units 1/2" (13 mm) conduit hole 4 9/32" (109mm) Cat. No. Lens Color Replacement Lens Electrical Ratings LED Life LED Ratings* 48SLEDA-G1 48SLEDB-G1 48SLEDG-G1 48SLEDR-G1 48SLEDA-N5 48SLEDB-N5 48SLEDG-N5 48SLEDR-N5 Amber Blue Green Red Amber Blue Green Red 96-LA 96-LB 96-LG 96-LR 96-LA 96-LB 96-LG 96-LR 24V DC 0.065A 120,000 hr. 120V 50/60 Hz 0.025A 120,000 hr. 38 lumens 35 lumens 102 lumens 28 lumens 38 lumens 35 lumens 102 lumens 28 lumens *Manufacturer's lumen rating is per LED. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 48SLED( )-G1 48SLED( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 4 5 65 25 .07/1 .09/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-9 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Flashing Light Weatherproof Protective Dome 49 Series FEATURES > 40 Watt Halogen Lamp in 120V AC Model The Edwards 49 Series AdaptaBeacon flashing lights are designed > Weatherproof shatter resistant polycarbonate lens. The polycarbonate double > Protective polycarbonate dome for easy cleaning fresnel lens ensures efficient light dispersion. This is accomplished with a series of complementing fresnels that cause the dome to > Cast base can be utilized as junction box with fresnel lenses. Lenses are available in six colors: red, amber, AGENCY APPROVALS Designed for indoor or outdoor installation. May be direct, 1/2" to provide a bright visual indication utilizing special optics within a "fill" when the light is operating. Beam distance is also increased blue, green, magenta, and clear (13mm) conduit, or box mounted on a 4" (102mm) octagon box. For weatherproof installation, units must be mounted vertically with lens > UL 1638 Listed > cUL Listed facing up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See Adaptabeacon Accessories, page 3-118. Edwards flashing lights are particularly effective in high noise level areas, especially where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Often used to signal malfunctions in equipment, such as 3-10 D-04 assembly line jams. Can warn personnel that they are entering a restricted area or an area of high danger. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 3/4" (171mm) 2" (51mm) 1/2" (13mm) NPT 3/4" (19mm) 6" (152mm) Lens Color Repl. Lens Repl. Dome 49R-N5-40WH 49A-N5-40WH 49B-N5-40WH 49G-N5-40WH 49M-N5-40WH 49C-N5-40WH Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 52-LC 49R-R5 49A-R5 49B-R5 49G-R5 49M-R5 49C-R5 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 52-LC Cat. No. Lamp Ratings Replacement Flasher Electrical Ratings Replacement Lamp 40 watts P-041917-0026 265 lumens* 3328 candlepower 25,000 hours** 120V 50/60 Hz 0.30 Amps 50LMP-40WH 25 watts P-041917-0038 232 lumens* 2914 candlepower 120 hours** 240V 50/60 Hz 0.10 Amps P-041917-0039 or Industry Trade No. 25T8/240V/DC/CL *Bulb manufacturer's lumen rating **Projected lamp life based on manufacturer's calculated long life at 65 FPM and 50% duty cycle. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-11 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Flashing Light PLC Compatible 50 Series FEATURES > Weatherproof The Edwards 50 Series AdaptaBeacon flashing lights are designed > 40 Watt Halogen lamp in 120V AC model; 20 Watt Halogen Lamp in 24V AC model > Cast base can be utilized as a junction box to provide a bright visual indication utilizing special optics within a shatter resistant polycarbonate lens. The polycarbonate double fresnel lens ensures efficient light dispersion. This is accomplished with a series of complementing fresnels that cause the dome to "fill" when the light is operating. Beam distance is also increased with fresnel lenses. Lenses are available in six colors: red, amber, AGENCY APPROVALS blue, green, magenta, and clear > UL 1638 Listed Designed for indoor or outdoor installation. May be direct, 1/2" > cUL Listed (13mm) conduit, or box mounted on a 4" (102mm) octagon box. For weatherproof installation, units must be mounted vertically with lens facing up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. For additional protection against breakage, use Cat. No. 92-GRD lens guard. See Adaptabeacon Accessories, page 3-118. Edwards flashing lights are particularly effective in high noise level areas, especially where ear protection must be worn and audible signals may not be heard or understood. They can advise personnel in manufacturing and process areas when an operation is starting or stopping. Often used to signal malfunctions in equipment, such as assembly line jams. Can warn personnel that they are entering a 3-12 D-04 restricted area or an area of high danger. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 5 7/8" (149mm) 3/4" (19mm) 2" (51mm) 6" (152mm) 1/2" (13mm) NPT Lens Color Replacement Lens Lamp Ratings Replacement Flasher Electrical Ratings Replacement Lamp 50R-N5-40WH 50A-N5-40WH 50B-N5-40WH 50G-N5-40WH 50M-N5-40WH 50C-N5-40WH Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 40 watts 265 lumens* 3328 candlepower 25,000 hours** P-041917-0026 120V 50/60 Hz 0.30 Amps 50LMP-40WH 50R-R5 50A-R5 50B-R5 50G-R5 50M-R5 50C-R5 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 25 watts 232 lumens* 2914 candlepower 120 hours** P-041917-0038 240V 50/60 Hz 0.10 Amps P-041917-0039 Industry Trade No. 25T8/240V/DC/CL 50R-G5-20WH 50A-G5-20WH 50B-G5-20WH 50G-G5-20WH 50M-G5-20WH 50C-G5-20WH Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 20 watts 226 lumens* 2839 candlepower 25,000 hours** P-041917-0029 24V 50/60 Hz 0.80 Amps 50LMP-20WH or Industry Trade No. 1692 Cat. No. *Bulb manufacturer's lumen rating **Projected lamp life based on manufacturer's calculated long life at 65 FPM and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 50( )-N5-40WH Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 120V AC 60 Hz 25 300 2/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-13 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Steady-on Lights PLC Compatible 50SIN Series FEATURES > Weatherproof The Edwards 50SIN Series AdaptaBeacon steady-on lights are > 40 Watt Halogen Lamp > Optically designed fresnel lens > Cast base can be utilized as junction box designed to meet continuous visual signaling requirements. The unique double fresnel lens is optically engineered to maximize brilliance. This is accomplished with a series of complementing fresnels that cause the dome to “fill” when the light is operating. Beam distance is also increased with fresnel lenses. The polycarbonate lenses are available in six colors: red, amber, blue AGENCY APPROVALS and green, magenta and clear. > UL 1638 Listed Designed for indoor or outdoor installation. May be direct, 1/2" (13mm) conduit, or box mounted on a 4" (102mm) octagon box on any plane. However, vertical installation ensures maximum beam > cUL Listed width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. Cat. No. 92-GRD lens guard is available for additional protection against lens breakage. See AdaptaBeacon Accessories on page 3-118. Ideally suited for light duty applications where a continuous steadyon incandescent light signal is required or where ambient noise makes audible signals difficult to hear. The gasketed weatherproof design assures installation acceptability in most industrial and 3-14 D-04 commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 5 7/8" (149mm) 3/4" (19mm) 2" (51mm) 6" (152mm) Cat. No. 50SINR-N5-40WH 50SINA-N5-40WH 50SINB-N5-40WH 50SING-N5-40WH 50SINM-N5-40WH 50SINC-N5-40WH 1/2" (13mm) NPT Lens Color Replacement Lens Lamp Ratings Electrical Ratings Replacement Lamp Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 40 Watts 265 lumens* 3328 candlepower 20,000 hours** 120V 50/60 Hz 0.29 Amps 50LMP-40WH *Manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 50SIN( )-N5-40WH Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 120V AC 60 Hz 25 290 0.47/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-15 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Flashing Light with Horn PLC Compatible 51 Series FEATURES > Weatherproof The Edwards 51 Series AdaptaBeacon flashing lights with horns are > Internal, base mounted horn rated at 85 dB at 10 feet (3.05 m) designed to provide a bright visual indication utilizing special optics > Cast base can be utilized as a junction box double fresnel lens ensures efficient light dispersion. This is accomplished with a series of complementing fresnels that cause AGENCY APPROVALS > AC models UL 1638 Listed > AC models cUL Listed within a shatter resistant polycarbonate lens. The polycarbonate the dome to "fill" when the light is operating. Beam distance is also increased with fresnel lenses. Lenses are available in six colors: red, amber, blue, green, magenta, and clear. The unique base design allows horn audibility while maintaining the unit's weatherproof integrity. Designed for indoor or outdoor installation. May be direct, 1/2" (13mm) conduit, or box mounted on a 4" (102mm) octagon box. For weatherproof installation, units must be mounted vertically with lens facing up. May be corner mounted indoors using the Cat. No. CBR, corner mount bracket, or wall mounted indoors using the Cat. No. WBR, wall mount bracket. For additional protection against breakage, use Cat. No. 92-GRD lens guard. See AdaptaBeacon Accessories, page 3-118. Edwards flashing lights with horns can advise personnel in manufacturing, process and commercial areas when an operation is starting or stopping. Often used in airport baggage carousels. Usually used for signaling equipment malfunctions, security intrusions, or pinpointing problem locations. Can warn personnel that they are entering a restricted area or an area of high danger. May be used where a smaller light output is desired or where many 3-16 D-04 multiple smaller flashing lights are specified. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 3/8" (187mm) 3 1/2" (89mm) 3/4" (19mm) 6" (152mm) 1/2" (13mm) conduit hole Lens Color Replacement Lens Lamp Ratings Replacement Flasher Electrical Ratings Replacement Lamp 51R-N5-40W 51A-N5-40W 51B-N5-40W 51G-N5-40W 51M-N5-40W 51C-N5-40W Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 40 watts 266 lumens* 3341 candlepower 3,920 hours P-041917-0026 120V 50/60 Hz 0.29 Amps 50LMP-40W (P-041695-0108) 51R-E1 51A-E1 51B-E1 51G-E1 51M-E1 51C-E1 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 24 watts 189 lumens* 2374 candlepower 700 hours** P-041917-0028 12V DC 1.0 Amps Industry Trade No. 94 51R-G1 51A-G1 51B-G1 51G-G1 51M-G1 51C-G1 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 24 watts 402 lumens* 5049 candlepower 3,180 hours** P-041917-0028 24V DC 1.1 Amps Industry Trade No. 1638 51R-G5-20W 51A-G5-20W 51B-G5-20W 51G-G5-20W 51M-G5-20W 51C-G5-20W Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 20 watts 402 lumens* 5049 candlepower 3,180 hours** P-041917-0029 24V 50/60 Hz 1.1 Amps Industry Trade No. 1638 Cat. No. *Bulb manufacturer's lumen rating **Projected lamp life based on manufacturer's calculated long life at 65 FPM and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 51( )-G1 51( )-N5-40W Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 25 25 1100 350 3/100 2/8 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-17 © Copyright 2004 Edwards D-04 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. VISUAL SIGNALS AdaptaBeacon® SteadyOn Lights with Horn PLC Compatible 51SIN Series FEATURES > Weatherproof The Edwards 51SIN Series AdaptaBeacon steady-on lights with > Internal, base mounted horn rated at 85 dB at 10 feet (3.05 m) horns are designed to provide a bright visual indication utilizing spe- > Cast base can be utilized as a junction box carbonate lens ensures efficient light dispersion. And, with no moving parts, the lights are immune to shock and vibration. Lenses AGENCY APPROVALS cial optics within a shatter resistant polycarbonate lens. The poly- available in six colors: red, amber, blue, green, magenta and clear. Unique base design allows sound audibility while maintaining the unit's weatherproof integrity. > AC models UL 1638 Listed > AC models cUL Listed Designed for indoor or outdoor installation. May be direct, 1/2" (13mm) conduit, or box mounted on a 4" (102mm) octagon box. For weatherproof installation, units must be mounted vertically with lens facing up. May be corner mounted indoors using the Cat. No. CBR, corner mount bracket, or wall mounted indoors using the Cat. No. WBR, wall mount bracket. For additional protection against breakage, use Cat. No. 92-GRD lens guard. See AdaptaBeacon Accessories, page 3-118. Edwards steady-on lights with horns can advise personnel in manufacturing and process areas when an operation is starting or stopping. Usually used for signaling equipment malfunctions, security intrusions, or pinpointing problem locations. Can warn personnel that they are entering a restricted area or an area of high danger. May be used where a smaller light output is desired or where many 3-18 D-04 multiple smaller flashing lights are specified. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 3/8" (187mm) 3 1/2" (89mm) 3/4" (19mm) 1/2" (13mm) conduit hole 6" (152mm) Cat. No. Lens Color Repl. Lens Lamp Ratings Repl. Horn Repl. Flasher Repl. Lamp Lamp Life** 51SINR-G1 51SINA-G1 51SINB-G1 51SING-G1 51SINM-G1 51SINC-G1 Red Amber Blue Green Magenta Clear 92-LR 24V DC P-047570-0743 92-LA 0.80A 92-LB 5049 candlepower 92-LG 402 Lumens* 92-LM 92-LC P-041917-0029 Industry Trade No. 1638 3180 Hours 51SINR-N5-40W 51SINA-N5-40W 51SINB-N5-40W 51SING-N5-40W 51SINM-N5-40W 51SINC-N5-40W Red Amber Blue Green Magenta Clear 92-LR 120V 50/60 Hz 92-LA 0.29A 92-LB 3341 candlepower 92-LG 266 Lumens* 92-LM 92-LC P-041917-0026 50LMP-40W or Industry Trade 25T8DC 3,920 Hours 123A-N5 * Bulb manufacturer's Lumen Rating ** Projected lamp life based on manufacturer's calculated lamp life at 65 FPM and 50% duty cycle. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 51SIN( )-G1 51SIN( )-N5-40W Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 24V DC 120V AC 60 Hz 25 25 1100 350 .9/1 .47/8 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-19 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Rotating Lights Weatherproof 52 Series FEATURES > Weatherproof Rotating signal designed to provide maximum brilliance and long > Light intensifying reflector > 75 revolutions per minute > Bayonet lamp socket for easy replacement > Cast base can be utilized as junction box > May be mounted vertically, facing up or down in 3 ways: - Direct Surface - 4" (102mm) octagon box - 1/2" (13mm) NPT conduit term durability with minimum maintenance. The polycarbonate dome allows for easy cleaning. May be mounted in any orientation. For direct mounting applications, unit is supplied complete with gasket and rubber expansion plugs. For weatherproof installation unit must be mounted vertically with the dome facing up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Designed to attract attention or indicate equipment malfunctions in noisy areas. Used in security systems to visually show indication of an intrusion. Also used in factory and distribution facilities to alert workers of oncoming fork truck traffic. AGENCY APPROVALS > UL 1638 Listed 3-20 D-04 > cUL Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 8 1/2" (216mm) 2" (51mm) 6" (152mm) Lens Color Replacement Lens Cat. No. Lamp Ratings Revolution Rate Electrical Ratings Replacement Lamp Cat. No. 52C-N5-40WH 52R-N5-40WH 52A-N5-40WH 52B-N5-40WH 52G-N5-40WH 52M-N5-40WH Clear Red Amber Blue Green Magenta 52-LC 52-LR 52-LA 52-LB 52-LG 52-LM 40 Watts 265 lumens* 3328 candlepower 25,000 hours** 75 rpm 120V 50/60 Hz 0.35 Amps 50-LMP-40WH 52C-G5-20WH 52R-G5-20WH 52A-G5-20WH 52B-G5-20WH 52G-G5-20WH 52M-G5-20WH Clear Red Amber Blue Green Magenta 52-LC 52-LR 52-LA 52-LB 52-LG 52-LM 20 Watts 226 lumens* 2839 candlepower 25,000 hours** 75 rpm 24V 50/60 Hz 0.8 Amps 50-LMP-20WH 52C-R5 52R-R5 52A-R5 52B-R5 52G-R5 52M-R5 Clear Red Amber Blue Green Magenta 52-LC 52-LR 52-LA 52-LB 52-LG 52-LM 25 Watts 232 lumens* 2914 candlepower 120 hours** 75 rpm 240V 50/60 Hz 0.10 Amps P-041917-0039 Industry Trade No. 25T8/240V/DC/CL Cat. No. *Manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-21 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Rotating Lights Weatherproof 53 Series FEATURES > Weatherproof Rotating signal designed to provide maximum brilliance and long > Light intensifying reflector > 75 revolutions per minute > Bayonet lamp socket for easy replacement > Cast base can be utilized as junction box allows for easy cleaning. For direct mounting applications, unit is supplied complete with gasket and rubber expansion plugs. For weatherproof installation unit must be mounted vertically with the dome facing up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Designed to attract attention or indicate equipment malfunctions in noisy areas. Used in security systems to visually show indication of an intrusion. Also used in factory and distribution facilities to alert workers of oncoming fork truck traffic. 3-22 D-04 > May be mounted vertically, facing up or down in 3 ways: - Direct Surface - 4" (102mm) octagon box - 1/2" (13mm) NPT conduit term durability with minimum maintenance. The polycarbonate dome 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 8 1/2" (216mm) 2" (51mm) 6" (152mm) Cat. No. Lens Color Replacement Lens Cat. No. Lamp Ratings Revolution Rate Electrical Ratings Replacement Lamp Cat. No. 53C-E1 53R-E1 53A-E1 53B-E1 53G-E1 Clear Red Amber Blue Green 52-LC 52-LR 52-LA 52-LB 52-LG 25 Watts 402 lumens* 5049 candlepower 200 hours** 75 rpm 12V DC 1.8 Amps Industry Trade No. 1076 53C-G1 53R-G1 53A-G1 53B-G1 53G-G1 Clear Red Amber Blue Green 52-LC 52-LR 52-LA 52-LB 52-LG 25 Watts 402 lumens* 5049 candlepower 500 hours** 75 rpm 24V DC 1.0 Amp Industry Trade No. 1638 *Manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-23 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Rotating Lights Diode Polarized for Supervised Circuits 53D Series FEATURES > Weatherproof Diode polarized rotating signal designed to provide maximum > Light intensifying reflector > Rotation of 75 revolutions per minute > Bayonet lamp socket for easy replacement > Cast base can be utilized as junction box brilliance and long term durability with minimum maintenance. The polycarbonate dome allows for easy cleaning. For direct mounting applications, unit is supplied complete with gasket and rubber expansion plugs. For weatherproof installation unit must be mounted vertically with the dome facing up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. Designed to attract attention or indicate equipment malfunctions in noisy areas. Used in security or other systems requiring the use of a diode polarized signal to visually show indication of an intrusion or equipment condition. Also used to alert worker of oncoming fork 3-24 D-04 truck traffic in factory and distribution facilities. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 8 1/2" (216mm) 2" (51mm) 6" (152mm) Cat. No. Lens Color Replacement Lens Cat. No. Lamp Ratings Revolution Rate Electrical Ratings Replacement Lamp Cat. No. 53DR-GW 53DC-GW Red Clear 52-LR 52-LC 25 Watts 402 lumens* 5049 candlepower 500 hours** 75 rpm 24 to 28V DC 1.0 Amp Industry Trade No. 1638 *Manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-25 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Light Double Flash NEMA Type 4X 57EDF Series FEATURES > 2.3 million peak candela strobe > Weatherproof The 57E Series AdaptaBeacon strobes are heavy-duty, double flash strobe lights designed for use in general signaling applications. The > Protective, easily cleaned clear polycarbonate outer dome > Immune to shock and vibration shatter resistant polycarbonate lens has been designed with a reflective double optics system that creates a unique rectangular column of light. This enhances light output by increasing the lens fill rate while minimizing the intense light burst normally characteristic of high intensity strobes. AGENCY APPROVALS The unit features a corrosion resistant, heat flowed epoxy finish > AC models UL 1638 Listed base. Lenses are available in five colors: red, amber, blue, green > UL Listed NEMA Type 4X enclosure and clear. > cUL Listed The strobe light may be installed vertically with the dome either facing up or facing down. For weatherproof installations units must Designed for indoor or outdoor installation on 3/4" (19 mm) conduit. be mounted vertically with dome up. Edwards double flash strobe lights are particularly effective in highnoise areas, especially where ear protection must be worn and audible signals may not be heard or understood. The Type 4X 3-26 D-04 enclosure ensures installation acceptability in most industrial and commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 8" (203 mm) 3/4" (19 mm) conduit hole 6 1/2" (168 mm) Peak Candlepower Lens Color Replacement Lens Electrical Ratings Replacement Strobe Tube Strobe Tube Life* Replacement Dome 57EDFR-G1 57EDFA-G1 57EDFB-G1 57EDFG-G1 57EDFM-G1 57EDFC-G1 2.3 million Red Amber Blue Green Magenta Clear 57E-LR 57E-LA 57E-LB 57E-LG 57E-LM 57E-LC 24V DC 2.2A 92-ST 3,000 Hours 57E-DC 57EDFR-N5 57EDFA-N5 57EDFB-N5 57EDFG-N5 57EDFM-N5 57EDFC-N5 2.3 million Red Amber Blue Green Magenta Clear 57E-LR 57E-LA 57E-LB 57E-LG 57E-LM 57E-LC 120V 50/60 Hz 0.2A 92-ST 3,000 Hours 57E-DC 57EDFR-R5 57EDFA-R5 57EDFB-R5 57EDFG-R5 57EDFM-R5 57EDFC-R5 2.3 million Red Amber Blue Green Magenta Clear 57E-LR 57E-LA 57E-LB 57E-LG 57E-LM 57E-LC 240V 50/60 Hz 0.1A 92-ST 3,000 Hours 57E-DC Cat. No. *Calculated strobe tube life at operating power to 75% efficiency D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-27 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Rotating Light Division 2 Rated, NEMA Type 4X, 100W Halogen Bulb 58 Series FEATURES > Weatherproof The Edwards 58 Series AdaptaBeacon is a high profile, heavy duty > Hazardous Location Listed > Motor driven reflector > 100W Bayonet Base Halogen Lamp AGENCY APPROVALS rotating beacon in a NEMA Type 4X enclosure designed to meet hazardous location requirements in industrial, commercial, or institutional applications. The polycarbonate dome allows for easy cleaning. The light mounts to 3/4" (19mm) NPT conduit. It may be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See > UL 1638 Listed AdaptaBeacon Accessories, page 3-118. For weatherproof > cUL Listed > UL Listed for Class I, Division 2, Groups A, B, C & D; Class II, Division 2, Groups F & G; and Class III hazardous locations. applications, the unit must be mounted vertically, with the dome facing up. Domes are available in six colors: red, amber, blue, green, magenta and clear. Ideally suited for applications where high ambient noise levels make audible signals difficult to hear or other types of visual > UL 1604 Listed signals (strobes or flashing lights) hard to distinguish. It can be used to inform of equipment status changes, communicate 3-28 D-04 malfunctions, or alert personnel to security breaches. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 7/8" (200mm) 1 3/4" (44mm) 3/4" (19mm) NPT 8 1/16" (205mm) Cat. No. 58R-N5-100WH 58A-N5-100WH 58B-N5-100WH 58G-N5-100WH 58M-N5-100WH 58C-N5-100WH Lens Color Replacement Dome Revolution Rate Electrical Ratings Lamp Ratings Replacement Lamp Red Amber Blue Green Magenta Clear 94DV2-DR 94DV2-DA 94DV2-DB 94DV2-DG 94DV2-DM 94DV2-DC 75 rpm 120V AC 50/60 Hz 1.0 Amp 1,800 lumens* 1620 candlepower 1,000 hours** 100Q/CL/DC/120V *Manufacturer's lumen rating. **Projected lamp life based on manufacturer's calculated lamp life @ 65 FPM and 50% duty cycle. HAZARDOUS LOCATION LISTINGS Class Division Group Operating Temperature Code I 2 A,B,C,D T1 (450C, 842F) II 2 F,G T6 (85C, 185F) III 1 T6 (85C, 185F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-29 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Electronic Horn/Strobe Indoor, Surface Mount 867STR Series FEATURES > Low current draw > High dB output The Edwards 867STR AdaptaBeacon series is a bright, low current, high decibel, surface mount, combination electronic horn/strobe for > Terminals for easy wiring indoor use. It has been designed for mounting with the supplied back box. Strobe and horn may be operated independently. > Gray flame resistant housing The 867STR mounts to the gray, corrosion resistant surface box > Five lens colors > 150 candela strobe (clear lens) supplied with the unit. The box measures 5 5/8" (143mm) square by 3 5/16" (84mm) deep. > Complete with gasket and surface back box The 867STR AdaptaBeacon is for indoor wall mounting in manufacturing sites. Used where a distinctive visual or audible > Engineered thermoplastic housing signal is required for timing, scheduling, paging, process control, and general alarm applications. > 1,000 hour strobe tube AGENCY APPROVALS > Strobe - UL 1638 Listed 3-110 D-04 Horn - UL 464 Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 3 5/16" (84mm) 5 5/8" (143mm) 5 5/8" (143mm) Surface Box (supplied) 5 1/2" (140mm) Mounting Plate (supplied) 5 1/2" (140mm) Catalog Number Operating Voltage** Operating Current - Horn*** Operating Current - Strobe*** Operating Environment Strobe Flash Rate Sound Level Output Mounting Light Output UL 1638 5/8" (16mm) 867STR(*)-N5 867STR(*)-AQ 120V AC 24V AC 24V DC 21 mA 60 mA 20 mA 90 mA (RMS) 158 mA (RMS) 219 mA (AVG) Indoor: 85% relative humidity at 86F (30C); 32F to 120F (0 to 49C) variable ambient 1 flash per second 90 dBA at 10 ft. (3.05 m) in an Anechoic Chamber Indoor Surface Mount Clear Lens - 150 cd Amber Lens - 90 cd Green Lens - 70 cd Red Lens - 21 cd Blue Lens - 20 cd *Insert lens color: C - clear, R - red, G - green, B - blue or A - amber **Operating voltage: -20% to +10% of nominal voltage ***Horn and strobe currents are additive when connected in parallel. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-111 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Electronic Horn/Strobe Outdoor, Surface Mount 868STR Series FEATURES > Low current draw > High dB output The Edwards 868STR AdaptaBeacon series is a bright, low current, high decibel, surface mount, combination electronic horn/strobe for > Terminals for easy wiring indoor or outdoor use. It has been designed for mounting with the supplied back box. Strobe and horn may be operated independently. > Gray flame resistant housing The 868STR mounts to the gray, corrosion resistant weatherproof > Five lens colors > 150 candela strobe (clear lens) surface box supplied with the unit. The box measures 5 59/64" (150mm) square by 3 13/32" (87mm) deep. > Complete with gasket and weatherproof surface back box The 868STR AdaptaBeacon is for outdoor wall mounting in manufacturing sites. Used where a distinctive visual or audible > Engineered thermoplastic housing signal is required for timing, scheduling, paging, process control, and general alarm applications. > 1,000 hour strobe tube AGENCY APPROVALS > Strobe - UL 1638 Listed 3-112 D-04 Horn - UL 464 Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 5 59/64" (150mm) Weatherproof Surface Box (supplied) 3 13/32" (87mm) 5 59/64" (150mm) 5 1/2" (140mm) Mounting Plate (supplied) 5 1/2" (140mm) Catalog Number Operating Operating Operating Operating 5/8" (16mm) 868STR(*)-N5 Voltage** Current - Horn*** Current - Strobe*** Environment Strobe Flash Rate Sound Level Output Mounting Light Output UL 1638 868STR(*)-AQ 120V AC 24V AC 24V DC 21 mA 60 mA 20 mA 90 mA (RMS) 158 mA (RMS) 219 mA (AVG) Indoor: 85% relative humidity at 86F (30C); 32F to 120F (0 to 49C) variable ambient Outdoor: 95% relative humidity at 86F (30C); -31F to 150F (-35C to 66C) variable ambient 1 flash per second 90 dBA at 10 ft. (3.05 m) in an Anechoic Chamber Outdoor Surface Mount Clear Lens - 150 cd Amber Lens - 90 cd Green Lens - 70 cd Red Lens - 21 cd Blue Lens - 20 cd *Insert lens color: C - clear, R - red, G - green, B - blue or A - amber **Operating voltage: -20% to +10% of nominal voltage ***Horn and strobe currents are additive when connected in parallel. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-113 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Electronic Horn/Strobe Indoor, Flush Mount 869STR & 869DSTR FEATURES > Low current draw > High dB output The Edwards 869STR and 869DSTR AdaptaBeacon series are bright, low current, high decibel, surface mount, combination > Terminals for easy wiring > Gray flame resistant housing electronic horn/strobes for indoor, flush mount use. They have been designed for mounting in a standard 4" (102mm) square backbox with extension ring (total minimum depth of 3" (76mm)) (not > Five lens colors supplied). Strobe and horn may be operated independently. > 150 candela strobe (clear lens) The 869DSTR-G1 is a diode polarized 24V DC unit. > Diode polarized units available The 869STR AdaptaBeacon is for indoor flush mounting in manufacturing sites. Used where a distinctive visual or audible > Engineered thermoplastic housing > 1,000 hour strobe tube signal is required for timing, scheduling, paging, process control, and general alarm applications. AGENCY APPROVALS > Strobe - UL 1638 Listed 3-114 D-04 Horn - UL 464 Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION Standard North American 4" (102mm) sq. x 1 1/2" (38mm) deep electrical box with 1 1/2" (38mm) extension ring (not supplied) 5 1/2" (140mm) Mounting Plate (supplied) 5 1/2" (140mm) Catalog Number Operating Voltage** Operating Current - Horn*** Operating Current - Strobe*** Operating Environment Strobe Flash Rate Sound Level Output Mounting Light Output UL 1638 5/8" (16mm) 869STR(*)-N5† 869STR(*)-AQ† 120V AC 24V AC 24V DC 21 mA 60 mA 20 mA 90 mA 158 mA 219 mA Indoor: 85% relative humidity at 86F (30C); 32F to 120F (0 to 49C) variable ambient 1 flash per second 90 dBA at 10 ft. (3.05 m) in an Anechoic Chamber Indoor Surface Mount Clear Lens - 150 cd Amber Lens - 90 cd Green Lens - 70 cd Red Lens - 21 cd Blue Lens - 20 cd *Insert lens color: C - clear, R - red, G - green, B - blue or A - amber **Operating voltage: -20% to +10% of nominal voltage ***Horn and strobe currents are additive when connected in parallel. † Diode polarized units available in 24V DC. Order 869DSTR(*)-G1. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-115 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Indoor Strobe Flush or Surface Mount 89 Series FEATURES > Low current draw The Edwards 89 Series strobes are bright, 150 candela, low current > 150 effective candela strobe (clear lens) units for indoor use. The 89STR series strobe has been designed > Terminals for easy wiring designed for surface mounting on the supplied single gang surface box. The housing is made of a gray, engineered thermoplastic. for flush mounting and the 89SMSTR series strobe has been > 1,000 hour strobe tube AGENCY APPROVALS Used where a distinctive visual signal is required for timing, scheduling, paging, process control, general alarm, and warning applications. 3-30 D-04 > UL 1638 Listed 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION For Flush Mount: 1 Gang Handy Box or equivalent (not supplied) For Surface Mount: Surface Box P-047701-0232373 (supplied) Mounting Plate (supplied) 2 1/8" (51mm) 5" (127mm) 3 3/8" (86mm) Catalog Number 89STR(*)-N5 89SMSTR(*)-N5 Operating Voltage** Operating Current 120V AC 24V AC 24V DC 90 mA 158 mA (RMS) 219 mA Strobe Flash Rate Mounting 89STR(*)-AQ 89SMSTR(*)-AQ 1 flash per second 89STR(*) = Flush Mount 89SMTR(*) = Surface Mount (box supplied) Operating Environment 85% relative humidity at 86°F (30°C), 32 - 120°F (0 - 49°C) variable ambient temperature Light Output UL 1638 Clear Lens - 150 effective cd Amber Lens - 90 effective cd Green Lens - 70 effective cd Red Lens - 21 effective cd Blue Lens - 20 effective cd *Insert lens color: C - clear, R - red, G - green, B - blue or A - amber **Operating voltage range: -20% to +10% of nominal voltage D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-31 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe Weatherproof 90 Series FEATURES > Weatherproof The Edwards 90 Series AdaptaBeacon Light Duty strobe lights are > Optically designed fresnel lens > Protective polycarbonate dome cover provides easy cleaning > Cast base can be utilized as a junction box > Immune to shock and vibration AGENCY APPROVALS designed to maximize the strobe tube brilliance. This is accomplished with a series of complementing fresnels that cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. The 90 Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. > UL 1638 Listed Designed for indoor or outdoor installation. May be direct, 1/2" > cUL Listed any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be (13mm) conduit, or box mounted on a 4" (102mm) octagon box on mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. 90 Series strobes are designed for light duty applications in industrial, commercial, and institutional applications where short term intermittent visual signaling is required. Ideally suited for installations where high ambient light levels make traditional 3-32 D-04 rotating or flashing lights difficult to distinguish or where ambient noise levels make audible signals difficult to hear. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 15/16" (176mm) 2 11/16" (68mm) 1/2" (13mm) NPT 3/4" (19mm) 6" (152mm) Cat. No. Lens Color Replacement Lens Peak Candlepower Electrical Ratings Flash Rate Replacement Dome Replacement Strobe Tube 90R-N5 90A-N5 90B-N5 90G-N5 90M-N5 90C-N5 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 1,400,000 120V 50/60 Hz 0.1 Amps 65 fpm 52-LC 92-LST 5,000 hours* *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-33 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Light Portable 91B Series FEATURES > Weatherproof The Edwards 91B Series AdaptaBeacon heavy duty portable strobe > Battery operated (uses two 6V DC lantern batteries) lights are designed to maximize the strobe tube brilliance. This is > 65 flashes per minute the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving > Xenon flash tube viewer perception. Beam distance is also increased with external accomplished with a series of complementing fresnels that cause fresnel lenses. The 91B Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. The 91B Series heavy duty portable strobes are ideal for use in identifying repair areas, temporary barriers, or emergency 3-34 D-04 construction areas. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 5 1/2 (140mm) 2 (51mm) 7 1/4 (178mm) Cat. No. 91B-R 91B-A 91B-B 91B-G 91B-M 91B-C Lens Color Replacement Lens Red Amber Blue Green Magenta Clear 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC Voltage Peak Candlepower Replacement Strobe Tube 12V DC 300,000 91B-ST 300,000 cd* 3,000 hour** *Peak candela **Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-35 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe Weatherproof 92-N5 Series FEATURES > Weatherproof The Edwards 92 Series AdaptaBeacon Light Duty strobe features > Optically designed fresnel lens > Immune to shock and vibration > Cast base can be utilized as a junction box convenient size and brilliant light output. Complementing fresnels cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. Beam distance is increased with external fresnel lenses. Lenses are available in six colors: red, amber, blue, green, magenta and clear. AGENCY APPROVALS The 92 Series' trigger and timing circuits are included as integral > UL 1638 Listed parts of the power supply. Replacement costs are reduced as it is > cUL Listed necessary to replace only the strobe tube. Designed for indoor or outdoor installation. May be direct, 1/2" (13mm) conduit, or box mounted on a 4" (102mm) octagon box on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. Cat. No. 92-GRD lens guard is available for additional protection against lens breakage. See AdaptaBeacon Accessories on page 3-118. 92 Series strobes have been designed for light duty applications in industrial, commercial, and institutional applications where short term intermittent visual signaling is required. They are ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish or where ambient 3-36 D-04 noise levels make audible signals difficult to hear. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 1/8" (156mm) 3/4" (19mm) 2 1/16" (52mm) 6" (152mm) Cat. No. 92R-N5 92A-N5 92B-N5 92G-N5 92M-N5 92C-N5 Lens Color Red Amber Blue Green Magenta Clear Replacement Lens 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC Electrical Rating 120V 50/60 Hz 0.1 Amps 1/2" (13mm) NPT Peak Candlepower 1,400,000 Flash Rate 65 FPM Replacement Strobe Tube 92-LST 5,000 hour* *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-37 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe Weatherproof 92-R5 and -S1 Series FEATURES > Optically designed fresnel lens > Xenon flash tube The Edwards 92 Series AdaptaBeacon Light Duty strobe features convenient size and brilliant light output. Complementing fresnels > Immune to shock and vibration > Cast base can be utilized as a junction box cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. Beam distance is increased with external fresnel lenses. Lenses are available in six colors: red, amber, blue, green, magenta and clear. AGENCY APPROVALS The 92 Series' trigger and timing circuits are included as integral > UL 1638 Listed (92-R5) parts of the power supply. Replacement costs are reduced as it is > cUL Listed necessary to replace only the strobe tube. Designed for indoor or outdoor installation. May be direct, 1/2" (13mm) conduit, or box mounted on a 4" (102mm) octagon box on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. Cat. No. 92-GRD lens guard is available for additional protection against lens breakage. See AdaptaBeacon Accessories on page 3-118. 92 Series strobes have been designed for light duty applications in industrial, commercial, and institutional applications where short term intermittent visual signaling is required. They are ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish or where ambient 3-38 D-04 noise levels make audible signals difficult to hear. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 1/4" (159mm) 1 7/8" (48mm) 5 5/8" (221mm) Cat. No. Lens Color Replacement Lens Electrical Rating Peak Candlepower Flash Rate Replacement Strobe Tube 92R-S1 92A-S1 92B-S1 92G-S1 92M-S1 92C-S1 92R-R5 92A-R5 92B-R5 92G-R5 92M-R5 92C-R5 Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear V93-LR V93-LA V93-LB V93-LG V93-LM V93-LC V93-LR V93-LA V93-LB V93-LG V93-LM V93-LC 250V DC 0.05 Amps 800,000 65 FPM 92-ST 3,000 hour* 240V 50/60 Hz 0.05 Amps 800,000 65 FPM 92-ST 3,000 hour* *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-39 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe PLC Compatible 92PLC Series FEATURES > Circuit designed for programmable logic control The Edwards 92PLC AdaptaBeacon signals are general purpose > Optically designed fresnel lens strobe is electrically isolated from leakage current to prevent false > Cast base may be used as a junction box flashes and has been designed for PLC applications. The unit also installs easily without having to add drop resistors to the PLC out- visual signaling appliances suitable for indoor or outdoor use. The put card. > Immune to shock and vibration > Single and double flash models The unit features a corrosion resistant, heat flowed epoxy finish base. Designed for indoor or outdoor installation. May be direct, 1/2" AGENCY APPROVALS (13mm) conduit, or box mounted on a 4" (102mm) octagon box. For > UL 1638 Listed weatherproof installation, units must be mounted vertically with lens facing up. > cUL Listed Edwards flashing lights are particularly effective in high noise level areas, especially where ear protection must be worn and audible signals may not be heard or may be misunderstood. They can advise personnel in manufacturing and process control areas when an 3-40 D-04 operation is starting or stopping. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 6 1/4" (159mm) 1 7/8" (48mm) 5 5/8" (221mm) Cat. No. Type Lens Color Replacement Lens Electrical Ratings Replacement Strobe Tube Peak Candlepower Strobe Tube Life* 92PLCR-N5 92PLCA-N5 92PLCB-N5 92PLCG-N5 92PLCM-N5 92PLCC-N5 Single Flash Red Amber Blue Green Magenta Clear V93-LR V93-LA V93-LB V93-LG V93-LM V93-LC 120V 50/60 Hz 0.1 Amps 92-LST 1,400,000 cd** 1,400,000 5,000 hr. 92PLC-DFR-N5 92PLC-DFA-N5 92PLC-DFB-N5 92PLC-DFG-N5 92PLC-DFM-N5 92PLC-DFC-N5 Double Flash Red Amber Blue Green Magenta Clear V93-LR V93-LA V93-LB V93-LG V93-LM V93-LC 120V 50/60 Hz 0.1 Amps 92-ST 800,000 cd** 800,000 3,000 hr. *Calculated strobe tube life at operating power to 75% efficiency. SIGNAL INPUT LOAD CHARACTERISTICS* Cat. No. 92PLC( )-N5 92PLC-DF( )-N5 Operating Voltage Max. off state leakage current (mA) Continuous on Current (mA) Surge (inrush/duration) Amps/milliseconds 120V AC 60 Hz 120V AC 60 Hz 5 5 100 100 20/.075 20/.075 *This device is PLC compatible and may be operated by PLCs with output characteristics that match the input load requirements of this signal. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-41 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Weatherproof 93 & 93DF Series FEATURES > Weatherproof The Edwards 93 Series AdaptaBeacon Heavy Duty strobe lights are > Single and double flash models > Optically designed fresnel lens > Cast base may be used as a junction box for use where more frequent and longer lasting signaling cycles may be required. They are designed with a series of complementing fresnels that cause the dome to "fill" with light each time the strobe flashes. Beam distance is increased with external fresnel lenses. These strobes are also available in "double flash" versions that > Immune to shock and vibration double the on-time (50 double flashes per minute). AGENCY APPROVALS The 93 Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is > UL 1638 Listed necessary to replace only the strobe tube. > cUL Listed Designed for indoor or outdoor installation. May be direct or 3/4" (19mm) conduit mounted on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations, units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. The 93 Series is ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. The gasketed weatherproof design assures installation acceptability in most industrial and commercial locations. They are used to signal equipment malfunctions, security 3-42 D-04 intrusions, or pinpointing problem locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 3/16" (183mm) 2 3/16" (71mm) 3/4" (19 mm) conduit hole 8 1/16" (205mm) Cat. No. 93R-N5 93A-N5 93B-N5 93G-N5 93M-N5 93C-N5 93R-R5 93A-R5 93B-R5 93G-R5 93M-R5 93C-R5 93DFR-N5 93DFA-N5 93DFB-N5 93DFG-N5 93DFM-N5 93DFC-N5 93DFR-R5 93DFA-R5 93DFB-R5 93DFG-R5 93DFM-R5 93DFC-R5 Lens Color Type Flash Replacement Lens Electrical Ratings Replacement Strobe Tube Peak Candlepower Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Single 65 fpm 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 120V 50/60 Hz 0.1 Amp 92-ST 3,000 hour* 800,000 cd 240V 50/60 Hz 0.05 Amp 92-ST 3,000 hour* 800,000 cd 120V 50/60 Hz 0.1 Amp 92-ST 3,000 hour* 1,100,000 cd 240V 50/60 Hz 0.05 Amp 92-ST 3,000 hour* 1,100,000 cd Single 65 fpm Double 50 dfpm Double 50 dfpm *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-43 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Single and Double Flash 94 & 94DF Series FEATURES > Weatherproof The Edwards 94 Series AdaptaBeacon Heavy Duty strobe lights are > Optically designed fresnel lens > Easily cleaned shatter resistant polycarbonate dust cover for use where more frequent and longer lasting signaling cycles may be required. They are designed to maximize the strobe tube brilliance. This is accomplished with a series of complementing fresnels that cause the dome to "fill" with light each time the strobe > Six lens colors available flashes. This design feature increases the AdaptaBeacon "on-time", > Immune to shock and vibration thus improving viewer perception. These strobes are also available > Cast base may be used as a junction box AGENCY APPROVALS in "double flash" versions that double the on-time (50 double flashes per minute). The 94 Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is > UL 1638 Listed necessary to replace only the strobe tube. > cUL Listed The 94 Series is also ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. The gasketed weatherproof design assures installation acceptability in most industrial and commercial locations. They are often used to signal equipment malfunctions, 3-44 D-04 security intrusions, or pinpointing problem locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 7/8" (200mm) 3/4" (19mm) conduit hole 8 1/16" (205mm) Cat. No. 94R-N5 94A-N5 94B-N5 94G-N5 94M-N5 94C-N5 94R-R5 94A-R5 94B-R5 94G-R5 94M-R5 94C-R5 94DFR-N5 94DFA-N5 94DFB-N5 94DFG-N5 94DFM-N5 94DFC-N5 94DFR-R5 94DFA-R5 94DFB-R5 94DFG-R5 94DFM-R5 94DFC-R5 Lens Color Type Flash Replacement Lens Electrical Ratings Replacement Strobe Tube Peak Candlepower Replacement Dome Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Single 65 FPM 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 120V 50/60 Hz 0.10 Amp 92-ST 3,000 hour* 800,000 cd 94-DC 240V 50/60 Hz 0.05 Amp 92-ST 3,000 hour* 800,000 cd 94-DC 120V 50/60 Hz 0.10 Amp 92-ST 3,000 hour* 1,100,000 cd 94-DC 240V 50/60 Hz 0.05 Amp 92-ST 3,000 hour* 1,100,000 cd 94-DC Single 65 FPM Double 50 DFPM Double 50 DFPM *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-45 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Div. 2 Hazardous Location Diode Polarized 94DDV2 Series FEATURES > NEMA Type 4X Enclosure The Edwards 94DDV2 Series Division 2 AdaptaBeacons are high > Diode polarized for use in electrically supervised circuits profile visual signals, ideal for outdoor and wet locations requiring a > Optically designed fresnel lens complementing fresnels cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon > Heavy duty, high profile "on-time", thus improving viewer perception. Beam distance is also > Immune to shock and vibration increased with external fresnel lenses. > Cast base may be used as a junction box The units' series trigger and timing circuits are included as integral > Shatter resistant clear polycarbonate dome necessary to replace only the strobe tube. diode polarized, UL Listed, NEMA Type 4X enclosure. A series of parts of the power supply. Replacement costs are reduced as it is Designed for indoor or outdoor installation on 3/4" (19mm) conduit. AGENCY APPROVALS For weatherproof installations, unit must be mounted vertically, with the lens facing up. Mount on 3/4" (19mm) conduit with the lens > UL 1638 and 1604 Listed facing up. > UL Listed NEMA Type 4X enclosure The 94DDV2 is often used to signal warning, evacuation, > cUL Listed personnel danger, visual communications, work breaks, and phone manufacturing processes, stop start, equipment malfunction, calls. They are also ideally suited for installations where a larger, brighter visual signal is specified. The gasketed weatherproof design assures installation acceptability in most industrial and 3-46 D-04 commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 7/8" (200mm) 3/4" (19mm) conduit hole 8 1/16" (205mm) Cat. No. 94DDV2R-G1 94DDV2A-G1 94DDV2B-G1 94DDV2G-G1 94DDV2M-G1 94DDV2C-G1 Lens Color Replacement Lens Flash Rate Electrical Rating Replacement Dome Replacement Strobe Tube Peak Candlepower Red Amber Blue Green Magenta Clear 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 65 fpm 24V DC 1.2 Amps 94DV2-DC 92-ST 3,000 hour* 800,000 cd *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Division Group Operating Temperature Code I 2 A,B,C,D T3 (200C, 392F) II 2 F,G T6 (85C, 185F) III T6 (85C, 185F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-47 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Div. 2 Hazardous Location NEMA Type 4X 94DV2 Series F E AT U R E S > Weatherproof The Edwards 94DV2 Series Division 2, NEMA Type 4X > Optically designed fresnel lens > Heavy duty, high profile > Six lens colors available > Immune to shock and vibration AdaptaBeacons high profile visual signals, ideal for outdoor and wet locations requiring a UL Listed, NEMA Type 4X enclosure. A series of complementing fresnels that cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. Beam distance is also increased with external fresnel lenses. > Cast base may be used as a junction box > Shatter resistant clear polycarbonate dome AGENCY APPROVALS > UL 1638 and 1604 Listed > UL Listed NEMA Type 4X enclosure Trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Designed for indoor or outdoor installation on 3/4" (19mm) conduit. For weatherproof installations, unit must be mounted vertically, with the lens facing up. Mount on 3/4" (19mm) conduit with the lens facing up. The 94DV2 is often used to signal warning, evacuation, manufacturing processes, stop start, equipment malfunction, > cUL Listed personnel danger, visual communications, work breaks, and phone calls. They are also ideally suited for installations where a larger, brighter visual signal is specified. The gasketed weatherproof design assures installation acceptability in most industrial and 3-48 D-04 commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 7/8" (200mm) 3/4" (19mm) conduit hole 8 1/16" (205mm) Lens Color Replacement Lens Flash Rate Electrical Ratings Replacement Dome Replacement Strobe Tube Peak Candlepower Red Amber Blue Green Magenta Clear 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 65 fpm 120V 50/60 Hz 0.1 Amp 94DV2-DC 92-ST 3,000 hour* 800,000 cd Cat. No. 94DV2R-N5 94DV2A-N5 94DV2B-N5 94DV2G-N5 94DV2M-N5 94DV2C-N5 *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Division Group Operating Temperature Code I 2 A,B,C,D T3 (200C, 392F) II 2 F,G T6 (85C, 185F) III 1 T6 (85C, 185F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-49 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe with Horn 85 dB Audible/Visual Signal 95 Series FEATURES > Weatherproof The Edwards 95 Series AdaptaBeacon Light Duty strobe lights with > Optically designed fresnel lens > Internal, base mounted horn rated at 85 dB at 10 feet (3.05 m) internal horn are designed for light duty applications in industrial, commercial, and institutional applications where short term intermittent visual signaling is required. A series of complementing fresnels that cause the dome to "fill" with light each time the strobe > Immune to shock and vibration flashes. This design feature increases the AdaptaBeacon "on-time", > Cast base may be used as a junction box thus improving viewer perception. Beam distance is increased with AGENCY APPROVALS as it is necessary to replace only the strobe tube. > UL 1638 Listed Designed for indoor or outdoor installation. May be direct, 1/2" > cUL Listed (13mm) conduit, or box mounted on a 4" (102mm) octagon box on external fresnel lenses. Trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. Cat. No. 92-GRD lens guard is available for additional protection against lens breakage. See AdaptaBeacon Accessories, pg. 3-118. They are ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish or where ambient noise levels make audible signals difficult to hear. Usually used for signaling equipment malfunctions, security intrusions, or pinpointing problem locations. The gasketed weatherproof design assures installation acceptability in most 3-50 D-04 industrial and commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 3/8" (187mm) 3 1/2" (89mm) 3/4" (19mm) 1/2" (13mm) conduit hole 6" (152mm) Cat. No. Lens Color Replacement Lens Electrical Rating Flash Rate Replacement Strobe Tube Peak Candlepower 95R-N5 95A-N5 95B-N5 95G-N5 95M-N5 95C-N5 Red Amber Blue Green Magenta Clear 92-LR 92-LA 92-LB 92-LG 92-LM 92-LC 120V 50/60 Hz 0.1 Amps 65 FPM 92-LST 5,000 hour* 1,400,000 cd *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-51 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe NEMA Type 4X 96B & 98B Series FEATURES > Weatherproof The Edwards 96B Series AdaptaBeacon Light Duty strobe lights are > Snap-on high impact plastic base > Optically designed fresnel lens > Immune to shock and vibration low profile units that are designed for light duty applications in industrial, commercial, and institutional applications where short term intermittent visual signaling is required. A series of complementing fresnels cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon AGENCY APPROVALS "on-time", thus improving viewer perception. Beam distance is increased with external fresnel lenses. > UL 1638 Listed > UL Listed NEMA Type 4X enclosure > AC models cUL Listed The 96B Series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Designed for indoor or outdoor installation. May be direct or 1/2" (13mm) conduit mounted on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. The 96B Series strobe is usually used where a smaller output is desired or where multiple, smaller strobes are required. They are ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish or where ambient noise levels make audible signals difficult to hear. The gasketed weatherproof design assures installation acceptability in 3-52 D-04 most industrial and commercial locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 4 7/32" (108mm) 1/2" (13 mm) conduit hole 4 9/32" (109mm) Cat. No. Lens Color Replacement Lens Electrical Rating Flash Rate Replacement Strobe Tube Peak Candlepower 96BR-N5 96BA-N5 96BB-N5 96BG-N5 96BM-N5 96BC-N5 96BR-R5 96BA-R5 96BB-R5 96BG-R5 96BM-R5 96BC-R5 98BR-E1 98BA-E1 98BB-E1 98BG-E1 98BM-E1 98BC-E1 98BR-G1 98BA-G1 98BB-G1 98BG-G1 98BM-G1 98BC-G1 98BR-FY 98BA-FY 98BB-FY 98BG-FY 98BM-FY 98BC-FY Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 120V 50/60 Hz 0.10 Amp 65 FPM 91B-ST 3,000 hours* 300,000 cd 240V 50/60 Hz 0.02 Amp 65 FPM 91B-ST 3,000 hours* 300,000 cd 12V DC 0.5 Amp 65 FPM 91B-ST 3,000 hour* 300,000 cd 24V DC 0.3 Amp 65 FPM 91B-ST 3,000 hour* 300,000 cd 36V DC 0.3 Amp 65 FPM 91B-ST 3,000 hour* 300,000 cd D-04 *Calculated at operating power to 75% efficiency. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-53 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe Div. 2 Hazardous Location NEMA Type 4X 96DV2 Series FEATURES > Weatherproof The Edwards 96DV2 Series Division 2, NEMA Type 4X > Optically designed fresnel lens AdaptaBeacons are low profile units for use in light duty applications where short term intermittent signaling is required. > Low profile > Immune to shock and vibration AGENCY APPROVALS They are ideal for signaling equipment malfunction, manufacturing processes, work breaks, stop start, and evacuation. They are UL Listed for outdoor and wet locations requiring Division 2 and NEMA 4X specifications. > UL 1638 and 1604 Listed A series of complementing fresnels cause the dome to "fill" with > UL Listed NEMA Type 4X enclosure > cUL Listed light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. Beam distance is also increased with external fresnel lenses. Trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Designed for indoor or outdoor installation. May be direct or 1/2" (13mm) conduit mounted. The unit should be installed with the lens facing up. The 96DV2 Series is ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. The gasketed weatherproof design assures installation acceptability in most industrial and commercial 3-54 D-04 locations. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 4" (102mm) 4 1/8" (105mm) 5/8" (16mm) Cat. No. 96DV2R-N5 96DV2A-N5 96DV2B-N5 96DV2G-N5 96DV2M-N5 96DV2C-N5 Lens Color Replacement Lens Flash Rate Electrical Rating Replacement Strobe Tube Peak Candlepower Red Amber Blue Green Magenta Clear 96-LR 96-LA 96-LB 96-LG 96-LM 96-LC 65 fpm 120V 50/60 Hz 0.03 Amp 91B-ST 3,000 hour* 300,000 cd *Calculated at operating power to 75% efficiency. HAZARDOUS LOCATION LISTINGS Class Division Group Operating Temperature Code I 2 A,B,C,D T3C (160C, 320F) II 2 F,G T6 (85C, 185F) III T6 (85C, 185F) D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-55 © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Heavy Duty Strobe Single and Double Flash 97 & 97DF Series FEATURES > Weatherproof The Edwards 97 Series AdaptaBeacon Heavy Duty strobe lights are > Immune to shock and vibration > Optically designed fresnel lens > Cast base may be used as a junction box designed for use where more frequent and longer lasting signaling cycles may be required. A series of complementing fresnels cause the dome to "fill" with light each time the strobe flashes. Beam distance is also increased with external fresnel lenses. These strobes are also available in "double flash" versions that double the apparent strobe on-time (50 double flashes per minute). AGENCY APPROVALS The 97 Series' trigger and timing circuits are included as integral > UL 1638 Listed parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Designed for indoor or outdoor installation. May be direct or 3/4" (19mm) conduit mounted on any plane. However, vertical installation ensures maximum beam width projection. For weatherproof installations units must be mounted vertically with dome up. May be corner mounted using the Cat. No. CBR, corner mount bracket, or wall mounted using the Cat. No. WBR, wall mount bracket. See AdaptaBeacon Accessories, page 3-118. The 97 Series is also ideally suited for installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. The gasketed weatherproof design assures installation acceptability in most industrial and commercial 3-56 D-04 locations. Often used on forklifts, overhead cranes, and repair vehicles. 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com © Copyright 2004 Edwards VISUAL SIGNALS TECHNICAL INFORMATION 7 3/16" (183mm) 2 3/16" (71mm) 3/4" (19 mm) conduit hole 8 1/16" (205mm) Cat. No. 97R-EK 97A-EK 97B-EK 97G-EK 97M-EK 97C-EK 97R-MP 97A-MP 97B-MP 97G-MP 97M-MP 97C-MP 97DFR-EK 97DFA-EK 97DFB-EK 97DFG-EK 97DFM-EK 97DFC-EK 97DFR-MP 97DFA-MP 97DFB-MP 97DFG-MP 97DFM-MP 97DFC-MP Lens Color Type Flash Flash Rate Replacement Lens Electrical Rating Replacement Strobe Tube Peak Candlepower Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Red Amber Blue Green Magenta Clear Single 65 FPM 12-48V DC 1.2 Amp 92-ST 3,000 hour* 800,000 cd Single 65 FPM 72-125V DC 0.20 Amp 92-ST 3,000 hour* 800,000 cd Double 50 DFPM 12-48V DC 1.20 Amp 92-ST 3,000 hour* 1,100,000 cd Double 50 DFPM 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 93-LR 93-LA 93-LB 93-LG 93-LM 93-LC 72-125V DC 0.2 Amp 92-ST 3,000 hour* 1,100,000 cd *Calculated at operating power to 75% efficiency. D-04 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com 3-57 © Copyright 2004 Edwards FIRE ALARM EQUIPMENT AdaptaBeacon® Heavy Duty Strobe UL 1971 Listed 97DC-GW FEATURES The Edwards 97DC-GW AdaptaBeacon Heavy Duty strobe light is designed for use where more frequent and longer lasting signaling cycles may be required. A series of complementing fresnels cause the dome to "fill" with light each time the strobe flashes. Beam distance is also increased with external fresnel lenses. The 97DCGW's trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Designed for indoor or outdoor installations where high ambient light levels make traditional rotating or flashing lights difficult to distinguish. May be direct or 3/4" (19mm) conduit mounted on any plane. For gasketed weatherproof installations unit must be mounted vertically with dome up. > Weatherproof > Immune to shock and vibration > Optically designed fresnel lens > Cast base may be used as a junction box > May be corner mounted using Cat. No. CBR corner mount bracket or wall mounted using Cat. No. WBR wall mount bracket AGENCY APPROVALS > UL 1638 Listed > UL 1971 Listed for visual signaling use for the hearing impaired in non-sleeping areas > Red epoxy finish cast base 7 3/16" (183mm) 2 3/16" (71mm) 3/4" (19 mm) conduit hole 8 1/16" (205mm) Lens Color Type Flash Flash Rate Replacement Lens Electrical Rating Replacement Strobe Tube Peak Candlepower 97DC-GW Clear Single 65 FPM 93-LC 24-28V DC 1.40 Amp 92-ST 3,000 hour* 800,000 cd *Calculated at operating power to 75% efficiency. 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 www.edwards-signals.com 12-75 © Copyright 2002 Edwards D-002 Cat. No. VISUAL SIGNALS AdaptaBeacon® Light Duty Strobe Magnetic Base 99B Series FEATURES > 6 foot (183cm) cord with cigarette lighter plug-in adapter > Removable vinyl hood for driver's visual protection > Optically designed fresnel lens > Snap-on high impact polycarbonate/ABS base The Edwards 99B Series vehicular AdaptaBeacon warning light is a compact strobe unit that produces one million peak candlepower. A series of complementing fresnels that cause the dome to "fill" with light each time the strobe flashes. This design feature increases the AdaptaBeacon "on-time", thus improving viewer perception. Beam distance is also increased with external fresnel lenses. Each compact unit features a shatter resistant polycarbonate lens > Magnetic or velcro mounting that snaps onto a high impact polycarbonate/ABS base. The strobe is easily serviced with the use of a single flat-blade screwdriver. > Xenon-flash tube The 99B series' trigger and timing circuits are included as integral parts of the power supply. Replacement costs are reduced as it is necessary to replace only the strobe tube. Magnetic base allows temporary mounting to dash or vehicle roof. 4 7/32" (108mm) 3-58 D-04 4 9/32" (109mm) Cat. No. Lens Color Replacement Lens Electrical Rating Flash Rate Replacement Strobe Tube Peak Candlepower 99BR-E1 99BA-E1 99BB-E1 99BG-E1 99BC-E1 Red Amber Blue Green Clear 96-LR 96-LA 96-LB 96-LG 96-LC 12V DC 0.5 Amp 65 FPM 91B-ST 3,000 hour 300,000 cd 90 Fieldstone Court | Ph: 203.699.3300 | Cheshire, CT 06410 Fx: 203.699.3108 www.edwards-signals.com (calculated at operating power to 75% efficiency) © Copyright 2004 Edwards VISUAL SIGNALS AdaptaBeacon® Accessories FEATURES > Adds versatility and protection to many AdaptaBeaons > Easy to install/attach > Mounting brackets for use with any beacon which has either 3/4" or 1/2" conduit opening. The Edwards Mounting Brackets for walls or corners simply the installation of Edwards AdaptaBeacons. They may be used for mounting beacons that have either a 3/4" (19 mm) or 1/2" (12 mm) conduit opening. Backplates are made of stainless steel and bracket arms are cold rolled steel. The Corner Mount Bracket, Cat. No. CBR, can be used with surface installed 1/2" (12 mm) or 3/4" (19 mm) conduit mounting. The Wall Mount Bracket, Cat. No. WBR, can be used with either surface installed 1/2" (12 mm) or 3/4" (19 mm) conduit or concealed wiring. The Wall Mount Bracket mounts to a 4" (102 mm) square or 4" (102 mm) octagon electrical box or a 4" (102 mm) outdoor box. 3-108 D-002 The Catalog Number 92-GRD Protective Lens Guard is an easily installed guard that provides protection against lens breakage. 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 www.edwards-signals.com © Copyright 2002 Edwards VISUAL SIGNALS TECHNICAL INFORMATION Cat. No. CBR 5 3/4" (146mm) 5" (127mm) 1/4" (6mm) 6" (152mm) Cat. No. 92-GRD Cat. No. WBR 5" (127mm) 7" (178mm) 1/4" (6mm) 7" (178mm) 2" (51mm) 3 1/4" (83mm) Cat. Series 48 Series 49 Series 50 Series 50SIN Series 51 Series 51SIN Series 52 Series 53 Series 53D Series 58 Series 90 Series 91B Series 92 Series 93 Series 93DF Series 95 Series 96B Series 97 Series 97DF Series 98B Series 101 Series 4 15/16" (125mm) 2" (51mm) 2" (51mm) 2" (51mm) 5 1/16" (129mm) WBR X X X X X X X X X X X X X X X X X X X X X Can be used with: CBR X X X X X X X X X X X X X X X X X X X X X 92-GRD X X X X X X X D-002 90 Fieldstone Court | Cheshire, CT 06410 Ph: 203.699.3300 | Fx: 203.699.3108 www.edwards-signals.com 3-109 © Copyright 2002 Edwards