COLLIER COUNTY GOVERNMENT GROWTH MANAGEMENT DIVISION / PLANNING AND REGULATION 2800 N. Horseshoe Drive, Naples FL 34104 * Phone (239) 252-2400 Outstanding Corrections Date: February 11, 2014 Contact Name: PINEDA, JOSE Address: 1871 16TH ST NE City, State Zip: NAPLES , FL 34120Fax: <NO FAX NUMBER> PERMIT NO: PRBD2014020273301 APPLICATION NO: PRBD20140202733 JOB SITE ADDRESS: 3585 33rd AVE NE, Unit: Email:pinedabrosroofing@gmail.com Dear Applicant: Plans submitted with the referenced permit have been reviewed. We are unable to approve your permit application for the reason(s) indicated below. All corrections must be clouded. Corrections must be submitted in person, the office receiving corrections is open until 4:00 pm. JOB DESCRIPTION: NEW HOME TWO STORY - SFR3585 33RD AVE NE 3 BEDROOM 3-1/2 BATH RT Rejected Review: Residential Review Reviewed By: Richard Traverse Phone:239-252-2968 Email:richardtraverse@colliergov.net Correction Comment 1: Per Florida Building Code Residential Section R311.3.1 Landings or floors at the required egress door shall not be more than 1-1/2 inches lower than the top of the threshold. The plans as submitted do not meet this requirement. Exception: The exterior landing or floor shall not be more than 7-3/4 inches below the top of the threshold provided the floor does not swing over the landing or floor. Correction Comment 2: Per the 2008 National Electric Code 210.12 (B) Arc fault circuits shall be located in dwelling unit family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms. Please annotate plans to comply. Correction Comment 3: Per R314.3 FBC Residential, smoke alarms shall be installed in each sleeping room and outside each separate sleeping area in the immediate vicinity of bedrooms. Please provide. (Guest Room). Correction Comment 4: Please provide a large scale dimensional detail of stair tread and risers, stringers, handrail & graspability, guards, and guardrails in accordance with 2010 FBCode Residential Section R311. Also note R302.7. Correction Comment 5: The Door/Window Schedule specifies shutters for wind borne debris protection. The product approvals submitted are for impact and non-impact products. Please clasrify/revise the door/window schedule and/or provide the correct product approvals. If shutters are to be used for opening protection, please provide product approvals for shutters. Also needed: product approvals for exterior metal swing doors (several locations). Correction Comment 6: Please indicate on plans additional information for the fireplace/chimney, i.e., vent free, vented, etc. If vented please provide manufacturers specifications and chimney details to comply with Chapter 10 of the FBC Residential. Correction Comment 7: Please annotate plans to show compliance with FBCR Section R312 for the Balcony railings. Correction Comment 8: Please provide structural details for the concrete deck. Correction Comment 9: This review shall be considered incomplete pending receipt of the information requested. Subsequent reviews may reveal additional deficiencies. Rejected Review: Health Review Reviewed By: Duncan Freel Phone:239-252-5339 Email:duncan_Freel@doh.state.fl Correction Comment 1: Provide Application form DH4015 Pg 1 w/ correct total living area. (including guest room) Correction Comment 2: Provide new Site evaluation with 400gpd sewage flow to match building sqft (including guest room) Correction Comment 3: Provide new site plan with proposed tank and drainfield meeting minimum requirements. Rejected Review: Engineering Review Reviewed By: Kirsten Wilkie Phone:239-252-5518 Email:kirstenwilkie@colliergov.net Correction Comment 1: Property may exceed the allowable Impervious Cover amount for the property. The lot size area of 72,309.6 S.F. which would allow for a total of 5,429 S.F. for lot cover allowance (roofed structures) and 6,887 S.F. for Impervious cover allowance (roofed structures + driveway, patios, ect.). Please provide both proposed Lot Coverage (roofed) square footage and Impervious Coverage allowance (roofed structures + driveway, patios, ect.). If proposing over the allowed amount then an engineered stormwater system plan, signed and sealed by a registered Florida Professional Engineer is required for the excess per LDC 6.05.01 Below is a list to determine what is impervious and pervious. Impervious will be considered any surface which will not allow water to perculate into the ground. This would include (but not be limited to): Roofed building, concrete, asphalt, cool deck (i.e spraycrete), paver brick with limerock base below. Pervious would be any surface which would allow water to perculat into the ground. This would include (but not be limited to): grass, uniform graded stone (ie. #57), mulch, Pavers without limerock base, pond area. Rejected Review: FEMA Review Reviewed By: Richard Traverse Phone:239-252-2968 Email:richardtraverse@colliergov.net Correction Comment 1: Proposed structure is in Flood Zone AH16.5. Please provide the FFE to be at or above 16.5 ft NAVD and at or above 18" above the crown of the road elevation. The garage FFE must also be at or above flood zone elevation or provide hydrostatic flood vents. Submit 4 sets of revised sheets along with 4 letters of response addressing each item. PLEASE NOTE: Collier County Plan Review and Inspections routinely reviews all outstanding permit applications in order to determine their status. The review process includes appropriate responses from the permit applicant when the permit cannot be approved. When the applicant is advised of deficiencies and does not respond within 180 days with corrected plans or an appeal to the Code Enforcement Board, the permit application will be canceled as per Collier County Ordinance 2002-01, Section, 104.5.1.1 to 104.5.1.4. IMPORTANT: The new Digital Flood Insurance Rate Map (DFIRM) will be effective on March 30, 2012. All development and building permit must be in compliance with the DFIRM flood zone and flood elevation requirements beginning on March 30, 2012. Please note that applications submitted prior to March 30, 2012, but issued after March 29, 2012, must be in compliance with the DFIRM requirements.