Outstanding Corrections
Date: February 11, 2014
Contact Name: PINEDA, JOSE
Address: 1871 16TH ST NE
City, State Zip: NAPLES
, FL 34120Fax: <NO FAX NUMBER>
PERMIT NO: PRBD2014020273301
APPLICATION NO: PRBD20140202733
JOB SITE ADDRESS: 3585 33rd AVE NE, Unit:
Email:pinedabrosroofing@gmail.com
Dear Applicant:
Plans submitted with the referenced permit have been reviewed. We are unable to approve your permit application for the
reason(s) indicated below. All corrections must be clouded. Corrections must be submitted in person, the
office receiving corrections is open until 4:00 pm.
JOB DESCRIPTION: NEW HOME TWO STORY - SFR3585 33RD AVE NE 3 BEDROOM 3-1/2 BATH
RT
Rejected Review: Residential Review
Reviewed By: Richard Traverse
Phone:239-252-2968 Email:richardtraverse@colliergov.net
Correction Comment 1: Per Florida Building Code Residential Section R311.3.1 Landings or floors at the required egress door
shall not be more than 1-1/2 inches lower than the top of the threshold. The plans as submitted do not meet this requirement.
Exception: The exterior landing or floor shall not be more than 7-3/4 inches below the top of the threshold provided the floor
does not swing over the landing or floor.
Correction Comment 2: Per the 2008 National Electric Code 210.12 (B) Arc fault circuits shall be located in dwelling unit family
rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar
rooms. Please annotate plans to comply.
Correction Comment 3: Per R314.3 FBC Residential, smoke alarms shall be installed in each sleeping room and outside each
separate sleeping area in the immediate vicinity of bedrooms. Please provide. (Guest Room).
Correction Comment 4: Please provide a large scale dimensional detail of stair tread and risers, stringers, handrail &
graspability, guards, and guardrails in accordance with 2010 FBCode Residential Section R311. Also note R302.7.
Correction Comment 5: The Door/Window Schedule specifies shutters for wind borne debris protection. The product approvals
submitted are for impact and non-impact products. Please clasrify/revise the door/window schedule and/or provide the correct
product approvals. If shutters are to be used for opening protection, please provide product approvals for shutters. Also
needed: product approvals for exterior metal swing doors (several locations).
Correction Comment 6: Please indicate on plans additional information for the fireplace/chimney, i.e., vent free, vented, etc. If
vented please provide manufacturers specifications and chimney details to comply with Chapter 10 of the FBC Residential.
Correction Comment 7: Please annotate plans to show compliance with FBCR Section R312 for the Balcony railings.
Correction Comment 8: Please provide structural details for the concrete deck.
Correction Comment 9: This review shall be considered incomplete pending receipt of the information requested. Subsequent
reviews may reveal additional deficiencies.
Rejected Review: Health Review
Reviewed By: Duncan Freel
Phone:239-252-5339 Email:duncan_Freel@doh.state.fl
Correction Comment 1: Provide Application form DH4015 Pg 1 w/ correct total living area. (including guest room)
Correction Comment 2: Provide new Site evaluation with 400gpd sewage flow to match building sqft (including guest room)
Correction Comment 3: Provide new site plan with proposed tank and drainfield meeting minimum requirements.
Rejected Review: Engineering Review
Reviewed By: Kirsten Wilkie
Phone:239-252-5518 Email:kirstenwilkie@colliergov.net
Correction Comment 1: Property may exceed the allowable Impervious Cover amount for the property. The lot size area of
72,309.6 S.F. which would allow for a total of 5,429 S.F. for lot cover allowance (roofed structures) and 6,887 S.F. for
Impervious cover allowance (roofed structures + driveway, patios, ect.).
Please provide both proposed Lot Coverage (roofed) square footage and Impervious Coverage allowance (roofed structures +
driveway, patios, ect.). If proposing over the allowed amount then an engineered stormwater system plan, signed and sealed
by a registered Florida Professional Engineer is required for the excess per LDC 6.05.01
Below is a list to determine what is impervious and pervious.
Impervious will be considered any surface which will not allow water to perculate into the ground. This would include (but not be
limited to): Roofed building, concrete, asphalt, cool deck (i.e spraycrete), paver brick with limerock base below.
Pervious would be any surface which would allow water to perculat into the ground. This would include (but not be limited to):
grass, uniform graded stone (ie. #57), mulch, Pavers without limerock base, pond area.
Rejected Review: FEMA Review
Reviewed By: Richard Traverse
Phone:239-252-2968 Email:richardtraverse@colliergov.net
Correction Comment 1: Proposed structure is in Flood Zone AH16.5. Please provide the FFE to be at or above 16.5 ft NAVD
and at or above 18" above the crown of the road elevation. The garage FFE must also be at or above flood zone elevation or
provide hydrostatic flood vents.
Submit 4 sets of revised sheets along with 4 letters of response addressing each item.
PLEASE NOTE:
Collier County Plan Review and Inspections routinely reviews all outstanding permit applications in order to determine their
status. The review process includes appropriate responses from the permit applicant when the permit cannot be approved.
When the applicant is advised of deficiencies and does not respond within 180 days with corrected plans or an appeal to the
Code Enforcement Board, the permit application will be canceled as per Collier County Ordinance 2002-01, Section,
104.5.1.1 to 104.5.1.4.