2016 Baldor Catalog Excerpt

advertisement
INNOVATIVE
NEW PRODUCTS
STANDARD PRODUCT CATALOG
EFFICIENCY LEADER
INVENTORY
Effective: June 1, 2016
ENERGY
LOCAL
501
Large AC Motors
Large AC Motors Key Features..........................................................69
GPM (General Purpose Motor), Three Phase, Totally Enclosed,
Foot Mounted....................................................................................70
Severe Duty, Three Phase, Totally Enclosed, Foot Mounted...............73
Standard 2300/4160 Volt motor........................................................74
NEW! Three Phase, Open Drip Proof, Foot Mounted........................74
Division 2 Capabilities........................................................................75
Washdown Duty Motors
Washdown Duty Motors Key Features...............................................76
Single Phase, Totally Enclosed, Foot Mounted...................................77
Single Phase, Totally Enclosed, C-Face.............................................77
Three Phase, Totally Enclosed, Foot Mounted...................................78
Three Phase, Totally Enclosed, C-Face, Foot Mounted......................79
Three Phase, Totally Enclosed, C-Face, Footless...............................80
Three Phase, Totally Enclosed, C-Face, 575V....................................81
Feather Picker Motor, Three Phase, TEFC, Encapsulated,
Foot Mounted....................................................................................82
Feather Picker Motor, Three Phase, TEFC, Encapsulated,
C-Face, Foot Mounted......................................................................82
Brake Motor, Three Phase, Totally Enclosed, C-Face,
Foot Mounted....................................................................................83
Jet Pump, Three Phase, TEFC, C-Face.............................................83
General
Information
Single Phase
Motors
Explosion Proof Motors
Explosion Proof Motors Key Features................................................94
Explosion Proof, Single and Three Phase, Foot Mounted...................95
Explosion Proof, 575 Volt, Three Phase, Explosion Proof...................98
Explosion Proof, Single and Three Phase, C-Face.............................99
Explosion Proof, Single and Three Phase, NEMA Frame,
C-Face, Foot Mounted, 50 Hz.........................................................101
Explosion Proof, Severe Duty, Three Phase, 1.15 Service Factor.....102
Drill Rig Duty, Three Phase, 1.15 Service Factor..............................103
Drill Rig Duty, Single Phase, C-Face, 1.15 Service Factor,
Foot Mounted..................................................................................106
Drill Rig Duty, Close Coupled Pump.................................................107
Explosion Proof, Jet Pump, Footless...............................................107
Explosion Proof, Close-Coupled Pump, Three Phase......................108
Explosion Proof, Brake Motor, Three Phase, C-Face........................108
Explosion Proof, Inverter Duty, Class I, Group D, Foot Mounted.......109
Explosion Proof, Inverter Duty, Class I, Group D, C-Face,
Foot Mounted..................................................................................110
Explosion Proof, Inverter Duty, Class I, Group D,
Class II, Group F&G, C-Face, Foot Mounted, 10:1 CT, 10:1 VT.......110
Explosion Proof, Inverter Duty, Class I, Group C&D, Class II,
Group F&G T3C (160°C) Temperature Code, 4:1 CT, 10:1 VT..........111
Pump Motors
Pump Motors Key Features.............................................................112
NEW! Fire Pump, Three Phase, ODP, Foot Mounted.......................113
NEW! Fire Pump, Three Phase, ODP, Footless,
Close-Coupled Pump......................................................................114
Jet Pump, Single Phase, TEFC........................................................115
Jet Pump, Single Phase, ODP.........................................................116
Jet Pump, Three Phase, TEFC.........................................................117
Jet Pump, Three Phase, ODP..........................................................118
Washdown, Jet Pump, Three Phase, TEFC, C-Face........................119
Square Flange Pump, ODP..............................................................119
Close-Coupled Pump, Single Phase................................................120
Close-Coupled Pump, Three Phase, Foot Mounted,
With Internal Aegis® Bearing Protection Ring...................................121
Close-Coupled Pump, Three Phase, TEFC......................................122
Close-Coupled Pump, Three Phase, TEFC, Footless.......................125
Large AC
Motors
Severe Duty Motors Key Features......................................................43
Three Phase, Totally Enclosed, 230/460 Volts & 460 Volts,
575 Volts, Foot Mounted...................................................................44
Three Phase, Totally Enclosed, 460 & 230/460 Volts, C-Face............49
NEW! RPM XE, eXtreme Efficient, Totally Enclosed, 460 Volts...........51
IEEE 841, Three Phase, Totally Enclosed, 460 & 575 Volts.................52
IEEE 841, Three Phase, TEFC, 460 & 575 Volts, C-Face...................55
661XL / IEEE 841, Three Phase, TEFC, 460 Volts, Foot Mounted......57
NEW! Dirty Duty, Three Phase, TEFC................................................58
Quarry Duty Motors, Three Phase, TEFC, Design C, High Torque......60
NEW! Crusher Motors, Three Phase, TEFC, 460 Volts,
Foot Mounted....................................................................................61
Conversion base kit CB5744T...........................................................62
Oil Field Pump, Three Phase, TEFC and ODP, Design D,
Foot Mounted....................................................................................63
Division 2 Capabilities........................................................................64
Washdown Duty
Motors
Severe Duty Motors
Explosion Proof
Motors
Three Phase, Totally Enclosed, Foot Mounted...................................18
Three Phase, Totally Enclosed, C-Face, Foot Mounted......................26
Three Phase, Totally Enclosed, C-Face, Footless...............................29
Three Phase, Open Drip Proof, Foot Mounted...................................33
Three Phase, Open Drip Proof, C-Face, Foot Mounted......................38
Three Phase, Open Drip Proof, C-Face, Footless...............................39
F-2 Mount, Three Phase, TEFC and ODP, Foot Mounted...................41
Pump Motors
General Purpose Motors
Close-Coupled Pump, Three Phase, Totally Enclosed........................84
SSE Super-E Stainless Steel, Close-Coupled Pump,
Three Phase, Totally Enclosed, Encapsulated....................................85
Paint-Free, Three Phase, Totally Enclosed, C-Face............................86
Stainless Steel, Three Phase, Totally Enclosed, C-Face,
Foot Mounted....................................................................................87
Stainless Steel, Three Phase, Totally Enclosed, C-Face, Footless......88
SSE Super-E Stainless Steel, Three Phase, Totally Enclosed,
C-Face, Foot Mounted, Encapsulated...............................................89
SSE Super-E Stainless Steel, Three Phase, Totally Enclosed,
C-Face, Footless, Encapsulated........................................................90
SSE Super-E Stainless Steel, Three Phase, 575V,
Totally Enclosed, C-Face, Foot Mounted, Encapsulated....................91
Washdown Lead Connection Kits......................................................91
Inverter Motor, Paint Free, Three Phase, Totally Enclosed, C-Face.....92
Inverter Motor, Three Phase, TENV, C-Face, Foot Mounted...............93
Vector Motor, Three Phase, TENV, C-Face, Foot Mounted.................93
HVAC Motors
Single and Three Phase General Purpose Motors Key Features.........11
Single Phase, TEFC, Foot Mounted...................................................12
Single Phase, TEFC, C-Face.............................................................14
Single Phase, ODP, Foot Mounted.....................................................15
Single Phase, ODP, C-Face...............................................................17
Washdown Duty Motors (continued)
Farm Duty
Motors
Single Phase Motors
General Purpose
Industrial Motors
Table of Contents
Severe Duty
Motors
General Information
­1
General
Information
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
Large AC
Motors
Washdown Duty
Motors
Explosion Proof
Motors
Pump Motors
HVAC Motors
Farm Duty
Motors
­2
General Information
Table of Contents
Pump Motors (continued)
Close-Coupled Pump, Three Phase, ODP.......................................126
Washdown Close-Coupled Pump, Three Phase, Totally Enclosed...129
SSE Super-E Stainless Steel, Close-Coupled Pump,
Three Phase, Totally Enclosed, Encapsulated..................................130
P-Base Vertical Solid Shaft Pump, Three Phase, TEFC....................131
P-Base Vertical Solid Shaft Pump, Three Phase, ODP.....................133
SAE Hydraulic Pump Motors, Three Phase, Continuous Duty..........134
NEW! Submersible Motors, Single Phase, TENV.............................134
NEW! Submersible Motors, Three Phase, TENV.............................135
HVAC Motors
HVAC Motors Key Features.............................................................136
Super-E®, Three Phase, TEFC, Foot Mounted,
with Internal Baldor Shaft Grounding Brush.....................................137
Super-E®, Three Phase, ODP, Foot Mounted,
with Internal Baldor Shaft Grounding Brush.....................................138
Super-E®, Three Phase, TEFC, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring..................................139
Super-E®, Three Phase, ODP, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring..................................141
Super-E®, Three Phase, ODP, Foot Mounted...................................143
Super-E®, Three Phase, TEFC, Foot Mounted.................................145
Chiller/Cooling Tower, Three Phase, TEAO.......................................146
Chiller/Cooling Tower, Three Phase, Two Speed, TEFC....................147
Ventilation Fan, Three Phase, TEAO, C-Face, Footless....................147
Three Phase, TEAO, Foot Mounted.................................................148
Condenser Fan, Three Phase, ODP, “Belly Band” Round Body........149
Condenser Fan, Three Phase, TEAO, “Belly Band” Round Body......149
Fan and Blower, Single and Three Phase, ODP, Resilient Base........150
Three Phase, ODP...........................................................................151
(PSC) Direct Drive Fan, Single Phase, Foot Mounted, TEAO............151
Direct Drive Fan, Single and Three Phase, TEAO.............................152
Yoke/Pedestal Fan, Single Phase, PSC, TEAO................................152
Farm Duty Motors
Farm Duty Motors Key Features......................................................153
Super-E®, Three Phase, TEFC.........................................................154
Single Phase, TEFC.........................................................................155
Grain Dryer/Centrifugal Fan, Single and Three Phase,
TEFC and ODP................................................................................156
Grain Dryer/Vane Axial Fan, Single and Three Phase,
TEAO and OPAO.............................................................................157
Universal Crop Dryer, Single Phase, PSC (switchless), OPAO...........158
Irrigation Tower Drive, Three Phase, TENV.......................................158
Auger Drive, Single Phase, TEFC, Flange Mount, Capacitor Start....159
Grain Stirring, Single Phase, TEFC, Foot Mounted...........................159
Instant Reversing, Single Phase, TEFC, Foot Mounted....................160
Aeration Fan, Single and Three Phase, TEAO, Foot Mounted..........160
(PSC) - Direct Drive Fan, Single Phase, TEAO..................................161
Dairy/Vacuum Pump, Single Phase, TEFC, Foot Mounted...............161
Metering Pump, Three Phase, TEFC, Foot Mounted........................162
Incubator/Hatchery Vent Fan, Single Phase, TEAO..........................162
Definite Purpose Motors
NEW! Ammonia Compressor Motors..............................................163
Three Phase, Two Speed, TEFC, Foot Mounted..............................164
Definite Purpose Motors (continued)
Three Phase, Two Speed, ODP, Foot Mounted................................166
Pressure Washer, Single Phase, TEFC and ODP..............................167
U-Frame, Three Phase, TEFC..........................................................168
U-Frame, Single Phase....................................................................169
Automotive Duty, Three Phase, TEFC, Foot Mounted......................169
Single and Three Phase, TENV, Foot or C-Face Mounting,
Removable Base.............................................................................170
Synchronous Permanent Magnet, Three Phase, TEFC,
Foot Mounted..................................................................................170
Unit Handling Motors
Single and Three Phase, C-Face, TEFC...........................................171
High Cycle Brake Motor, Three Phase.............................................173
D-Series Brake Motor, Single Phase, TEFC, Footless.......................173
D-Series Brake Motor, Three Phase, Totally Enclosed......................174
D-Series and SSB Fast Response Brake Kit....................................175
Short Series Brake Motor, Three Phase, TEFC.................................176
Brake Motors
Single and Three Phase, TEFC........................................................177
Single and Three Phase, TEFC, C-Face, Fan on Drive End..............179
Three Phase, ODP...........................................................................180
Washdown, Three Phase, Totally Enclosed, C-Face,
Foot Mounted..................................................................................181
Double C-Face Motor Brake Kits.....................................................181
IEC Frame Motors
Metric IEC Frame Motors, Three Phase, IP55, 50/60 Hz,
Foot Mounted..................................................................................182
Metric IEC Frame Motors, Three Phase, 60 Hz, 460 Volts................185
Metric IEC Frame Motors, Three Phase, IP55, 60 Hz, 460 Volts.......186
Metric IEC Flange Kit for Process Performance Aluminum
and Cast Iron Motors (safe area)......................................................187
Metric IEC Frame Motors, Three Phase, IP55, 50/60 Hz,
B5 Flange........................................................................................187
Metric IEC ATEX/IECEX Flameproof Ex d IIC T4, IP55,
Three Phase, 50 Hz, Foot Mounted.................................................189
Metric IEC ATEX/IECEX Flameproof Ex de IIC T4, IP55,
Three Phase, 50 Hz, Foot Mounted.................................................190
Metric IEC ATEX/IECEX Non-Sparking Ex nA II T3, IP55,
Three Phase, 50 Hz, Foot Mounted.................................................191
Metric IEC Frame Motors, Three Phase, 60 Hz, 230/460 Volts.........192
Metric IEC Frame Motors, Three Phase, 60 Hz, 575 Volts................193
Metric IEC Frame Motors, 60 Hz. — Replacement Parts List...........194
Metric IEC Frame Motors, Three Phase, 60 Hz. – Dimensions.........195
Metric IEC, Three Phase, 60 Hz, TEFC, IP54, Foot Mounted...........196
Metric IEC, Three Phase, 60 Hz, TEFC, IP54, B5 Flange..................197
Metric IEC, Three Phase, 60 Hz, TEFC, IP54, B14 Face..................198
50 Hertz Motors
Single Phase, NEMA Frame, TEFC and ODP, Foot Mounted............199
Three Phase, NEMA Frame, TEFC and ODP, Foot Mounted............200
Single and Three Phase, NEMA Frame, TEFC, C-Face, Footless.....201
Single and Three Phase, NEMA Frame, Explosion Proof,
C-Face, Foot Mounted....................................................................202
General
Information
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
Large AC
Motors
Automotive Motor, Three Phase
Aeration Fan Motor, Single Phase
Aeration Fan Motor, Three Phase
Auger Fan Motor, Single Phase
Air Over Motor, Three Phase
Subfractional Hp, PM Motor
Brake Motor
Brake Motor, TENV enclosure
Tachometer Generator
NEMA C-Face with Base
Wound Field DC Motor NEMA C-Face with Base
Lifting Magnet Generator, C-Face
PM SCR Drive Motor
Paint Free Washdown PM SCR Drive Motor C-Face with Base
PM SCR Drive Motor with Integral Tachometer
Washdown PM SCR Drive Motor NEMA C-Face with Base
Explosion Proof PM SCR Drive Motor C-Face with Base
Explosion Proof Wound Field DC Motor, NEMA C-Face
Super-E Premium Efficient Motor, Single Phase, C-Face
Super-E Premium Efficient Motor, Three Phase, C-Face
Condenser Fan Motor, Permanent Split Capacitor
Condenser Fan Motor, Three Phase
Direct Drive Fan Motor, Permanent Split Capacitor
Direct Drive Fan Motor, Single Phase
Direct Drive Fan Motor, Three Phase
Washdown Jet Pump, Three Phase, Foot Mounted
Severe Duty Motor
Crusher Duty Motor
Checkout Stand Motor
Cooling Tower Motor, Three Phase
Dirty Duty - Three Phase, C-Face
Wound Field DC Motor
Direct Drive, Indoor Blower Motor, Permanent Split Capacitor
Dairy/Vacuum Pump Motor, Single Phase
Dirty Duty - Three Phase
Super-E Premium Efficient Motor
Super-E Severe Duty Motor
IEEE 661 Motor
IEEE 841 Motor
Super-E Severe Duty Motor, TENV
IEEE 841 Motor, TENV
TEFC Motor (when special)
Farm Duty Motor, Single Phase
Farm Duty Motor, Three Phase, Premium Efficient, Standard NEMA Frame
Filter Kit
F-2 Mounted Motor
Fire Pump Motor
Blower Kit
Washdown Duty Motor, TEFC, Three Phase
Grain Dryer Centrifugal Fan Motor
Grain Stirring Motor, Single Phase
HVAC Duty, F-2 Mounted Connection Box, Three Phase
Incubator/Hatchery Vent Fan Motor, Permanent Split Capacitor
HVAC Duty Motor, Three Phase
Hydraulic Pump Motor, Three Phase
RPMAC Inverter Drive Motor - Laminated Frame, TEBC
Inverter Drive Motor, Paint Free Washdown, C-Face with Base
RPMAC Inverter Drive Motor - Laminated Frame, DPG-FV
RPMAC Inverter Drive Motor - Laminated Frame, TEFC
Inverter Drive Motor, TEBC
Inverter Drive Motor, TENV
RPMAC Inverter Drive Motor - Laminated Frame, TENV
VS Master Inverter Drive Motor
VS Master Inverter Drive Motor, TENV
Inverter Drive Motor, Paint Free Washown, C- Face Less Base
Washdown Inverter Drive Motor, TENV
Explosion Proof Inverter Drive Motor, TEFC
Explosion Proof Inverter Drive Motor, TEFC, C-Face With Base
Irrigation Drive Motor
Instant Reversing Single Phase Farm Motor
56J Stainless Steel Threaded Shaft with Dripcover/ Jet Pump
JM Pump Shaft and Face
JP Pump Shaft & Face with Base/ Close Coupled Pump
JP Pump Shaft and Face with Base, Three Phase / Close Coupled Pump
Square Flange Pump Mount Motors with Threaded Shaft
Model 34 Diameter Motor with 56 C-Face, Less Base
Single Phase Motor
Three Phase Motor
Metric Dimension Motor with Base
Metering Pump Motor, Three Phase
Metric Dimension Motor, Flange Mount less Base, Three Phase
Totally Enclosed Non-Ventilated Motor
Oil Field Motor, Design D, High Slip
Pressure Washer Motor, C-Face with base, Single Phase
Tachometer Generator Foot Mount
Pressure Washer Motor, Single Phase
Permanent Split Capacitor Motor
Tachometer Generator
Repulsion-Start Induction-Run Motor
High Cycle Brake Motor, Three Phase
Definite Purpose HVAC Motors, Three Phase
Resilient Base Motor (Cradle Mount), Single Phase
Resilient Base Motor (Cradle Mount), Three Phase
Synchronous Permanet Magnet Motor
All Stainless Encapsulated Super-E Washdown Motor, Three Phase
All Stainless Washdown, Three Phase
Paint Free Washdown Duty Motor, Three Phase
Universal Crop Dryer Motor, Permanent Split Capacitor, Open Air Over
Universal Crop Dryer Motor, Permanent Split Capacitor, TEAO
Grain Dryer/Vane Axial Fan, Single Phase, Open Air Over
Grain Dryer/Vane Axial Fan, Single Phase, TEAO
Grain Dryer/Vane Axial Fan, Three Phase, Open Air Over
Grain Dryer/Vane Axial Fan, Three Phase, TEAO
Unit Handling Motor
Unit Handling Motor, Three Phase
NEMA C-Face Less Base
Two Compartment Jet Pump Motor C-Face less Base, Single Phase
Super-E Premium Efficient Motor, Three Phase, C-Face, Less Base
Super-E Vertical Pump Motor, Severe Duty - Normal Thrust
Vertical Pump Motor - Normal Thrust, Three Phase
Vertical Pump Motor, Severe Duty - Meduim Thrust
PM SCR Drive Motor with Metric Flange or C-Face
Vertical Pump Motor, Severe Duty - High Thrust
West Coast Fit TCZ
Washdown Duty Motor
Washdown Brake Motor, Three Phase
Yoke Pedestal Fan Motor, Permanent Split Capacitor
RPMAC Vector Drive Motor - Laminated Frame, TEBC
RPMAC Vector Drive Motor - Laminated Frame, TEFC
Vector Drive Motor, TEBC
Vector Drive Motor, TENV
RPMAC Vector Drive Motor - Laminated Frame, TENV
RPMAC Permanent Magnet Rotor - Laminated Frame
VS Master Severe Duty Vector Drive Motor
VS Master Vector Drive Motor
VS Master Severe Duty Vector Drive Motor, TENV
VS Master Vector Drive Motor, TENV
Washdown Vector Drive Motor, TENV
VS Master Vector Drive Motor, TENV
Washdown Vector Drive Motor, TENV
Washdown Duty
Motors
AEM
AFL
AFM
ANFL
AOM
AP
B
BN
BTG
C
CD
CDMG
CDP
CDPSWD
CDPT
CDPWD
CDPX
CDX
CEL
CEM
CFC
CFM
CHC
CHL
CHM
CJWDM
CP
CR
CSC
CTM
CDM
D
DDC
DEL
DM
E
ECP
ECP6
ECP8
ENCP
ENCP8
F
FDL
FDEM
FLT
FM
FP
FVB
FWDM
GD
GSL
HFM
HIC
HM
HPM
IDBRPM
IDCSWDM
IDDRPM
IDFRPM
IDM
IDNM
IDNRPM
IDVSM
IDVSNM
IDVSWDM
IDWNM
IDXM
IDXCM
IM
IR
J
JM
JP
JPM
JS
K
L
M
MM
MP
MVM
N
OF
PCL
PFTG
PL
PSC
PTG
R
RBM
RHM
RL
RM
SPM
SSEWDM
SSWDM
SWDM
UCC
UCCE
UCL
UCLE
UCM
UCME
UH
UHM
V
V2L
VEM
VHECP
VHM
VLCP
VP
VPCP
WC
WD
WDBM
YPC
ZDBRPM
ZDFRPM
ZDM
ZDNM
ZDNRPM
ZDPM
ZDVSCP
ZDVSM
ZDVSNCP
ZDVSNM
ZDWNM
ZDVSNM
ZDWNM
Explosion Proof
Motors
Motors Prefix
Pump Motors
or number(s) may also be part of the catalog number. For example L3510 or L3510T. Following is a list of prefix and suffix definitions.
HVAC Motors
Abbreviations: The Basic Baldor catalog number consists of a letter(s) prefix and several non-significant proceeding numbers. A suffix letter(s) and/
Farm Duty
Motors
General Information
­9
General
Information
General Information
Gearing Prefix
Single Phase
Motors
BK
G
DR
GC
GCP
GF
GHF
GHH
GHL
General Purpose
Industrial Motors
GHM
GIF
GLF
GLP
Severe Duty
Motors
Large AC
Motors
GM
GMP
GP
GPP
GS
GSF
IDGM
IDGMP
SSGF
SSGHF
WDGF
TA
Single Phase Gearmotor Kit
Subfractional Hp Gear Motor
Double Reduction Adapter Kit
Subfractional Hp Gear Motor Permanent Split Capacitor and Split Phase
Parallel Shaft Subfractional Hp Gear Motor Permanent Split Capacitor
and Split Phase
900 Series Reducers
900 Series Hollow Shaft Reducers
H50 Hollow Shaft Reducers
Hollow Shaft Subfractional Hp Gear Motor Capacitor Start Induction Run
and Capacitor Start Capacitor Run
Hollow Shaft Subractional Hp Gear Motor Three Phase
Inline Helical Reducers
900 Series Flanged Coupling Reducers
Subfractional Hp Gear Motor Capacitor Start Induction Run and Capacitor
Start Capacitor Run
Subfractional Hp Gear Motor Three Phase
Parallel Shaft Subfractional Hp Gear Motor Three Phase
PM Subfractional Hp Gear Motor
PM Parallel Shaft Subfractional Hp Gear Motor
900 Series Solid Shaft Reducers
Universal Series Right Angle Gear Reducers
Inverter Drive Subfractional Hp Gear Motor
Inverter Drive Parallel Shaft Subfractional Hp Gear Motor
Stainless Steel 900 Series Flanged Quill Reducers
Stainless Steel 900 Series Hollow Shaft Reducers
Washdown 900 Series Flanged Quill Reducers
Torque Arm
Kits & Accessories Prefix
Washdown Duty
Motors
Explosion Proof
Motors
Pump Motors
HVAC Motors
Farm Duty
Motors
­10
BLW
BU
CBL
CC
EN
FCD
FFC
FL
RBT
RES
TK
Blower Kit
Bushing Kit
Cable Assembly
Corrective Capacitor Bank
Encoder Kit
Drip Cover Kit
Fan Cover/Conduit Box Kit
Flange Kit
Roller Bearing Conversion Kit
Resolver Feedback Kit
Tachometer Mounting Kit
Motors Suffix
/35
/36
-2
-2/4
-4
-5
-8
-9
-12
-50
-57
-58
-277
-2340
-AP
-PP
-BG
-BV
-C
-CI
-D
-EX1
-EX2
-EX3
Full 140 Frame Band Diameter
Full 180 Frame Band Diameter
120/240V Field
200/400 Volt Winding
460 Volt Winding
575 Volt Winding
200 Volt Winding
NEMA Design C High Torque Winding
12 Leads
Wound for 50 Hertz Service
230/380-415 Volt Winding
380-415 Volt Y-Start/Delta-Run
277 Volt Winding
2300/4000 Volt Winding
Aluminum Process Performance
Cast Iron Process Performance
Baldor Shaft Ground Motor
Blower Vented
Listing includes Class I, Group C
Cast Iron Frame
Dodge D-Series Brake
Ex nA
Ex d
Ex de
-G
-I
-NL
-P
-S
-TP
A
C
D
E
L
LR
M
P
S
T
TP
TR
TS
Y
Aegis Shaft Ground Motor
Explosion-Proof, 1.15 Service Factor
Non Linear - For VFD use
Partial AC Motor Excludes Pulley Endplate
Dodge Short-Series Brake
Refrigerator Fan Motor
Automatic Thermal Overload
IEC Frame B14 Face Mount
IEC Frame B5 Flange Mount
New electrical design
Long shafted motor with Ball bearings that may be converted to have
D.E. Roller bearing.
Long shafted motor with D.E. Roller bearing that may be converted to
Ball bearings.
Manual Thermal Overload
Wound Field DC Motor NEMA “AT” Frame
Motor has a short shaft for coupled loads
NEMA “T” Frame Dimensions
Feather Picker Motor
NEMA “T” Frame - Roller Bearing
NEMA “T” Frame - Short Shaft
Special Mounting Dimension
Gearing Suffix
900 Series
A
56C Motor Flange
B
140TC Motor Flange
C
180TC Motor Flange
G
Left Hand Output Shaft
H
Double End Output Shaft
J
Right Hand Output Shaft
Universal Series
A
56C or Right Hand Output Shaft
B
140TC Motor Flange
C
180TC Motor Flange
Grinders Suffix
D
E
W
Deluxe
Exhaust Guards
Wide Design
3
5
7 1/2
10
15
20
1
1 1/2
2
3
5
7 1/2
10
15
RPM
NEMA
Frame
Catalog
Number
List
Price
3600
1800
3600
1800
3600
1800
3600
1800
3600
1800
3600
1800
182JM
182JM
184JM
184JM
213JM
213JM
215JM
215JM
254JM
254JM
256JM
256JM
EJMM3610T-G
EJMM3611T-G
EJMM3613T-G
EJMM3615T-G
EJMM3709T-G
EJMM3710T-G
EJMM3711T-G
EJMM3714T-G
EJMM2394T-G
EJMM2333T-G
EJMM4106T-G
EJMM2334T-G
1,157
1,252
1,333
1,255
1,735
1,854
1,953
2,133
3,384
3,357
3,697
3,750
1800
1800
1800
3600
1800
3600
1800
3600
1800
3600
1800
3600
1800
143JM
145JM
145JM
145JM
182JM
182JM
184JM
184JM
213JM
213JM
215JM
215JM
254JM
EJMM3116T-G
EJMM3154T-G
EJMM3157T-G
EJMM3158T-G
EJMM3211T-G
EJMM3212T-G
EJMM3218T-G
EJMM3219T-G
EJMM3311T-G
EJMM3312T-G
EJMM3313T-G
EJMM3314T-G
EJMM2513T-G
873
931
1,003
1,116
1,134
1,340
1,255
1,546
1,831
1,984
1,959
2,479
2,804
Mult.
Sym.
“C”
Dim.
Aprx.
Wt. (lb)
Totally Enclosed Fan Cooled
L1
16.91
60
L1
18.06
76
L1
18.06
81
L1
19.56
93
L1
19.76
124
L1
20.89
134
L1
19.76
124
L1
22.38
165
L1
25.30
260
L1
25.30
265
L1
25.30
274
L1
25.30
308
Open Drip Proof
L1
13.75
37
L1
13.75
41
L1
14.25
44
L1
15.13
51
L1
16.50
74
L1
15.12
64
L1
18.00
88
L1
16.50
78
L1
18.19
120
L1
18.19
121
L1
19.31
132
L1
18.19
134
L1
23.19
213
(a) See notes on inside back flap.
Full Load
Efficiency
Voltage
Full Load
Amps
Notes (a)
86.5
89.5
88.5
89.5
89.5
91.7
90.2
91.7
91
92.4
91
93
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
3.6
4.2
5.9
6.7
9
9.4
11.8
12
17.5
18.1
23
24
30
30
30
30
30
30
30
30
30
30
30
30
85.5
86.5
86.5
85.5
89.5
86.5
89.5
88.5
91
89.5
91.7
90.2
93
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
1.5
2.2
2.9
3.8
4.2
6
6.6
8.6
9.7
12
12.5
17.5
17.7
30
30
30
30
30
30
30
30
30
30
30
30
30
General
Information
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
Large AC
Motors
Hp
Applications:
• Commercial pumps
• Pairing with a Speed
Drive
• General Purpose
Pumps
• Industrial Pumps
• Food and Beverage
• Agricultural
Washdown Duty
Motors
Features:
• Internal grounding brush for bearing current
mitigation on DE retainer ring
• Class H insulation for increased protection on
Inverter use
• Oversize ball bearings for the pump industry
• Locked DE bearing to allow mounting in any
configuration
• Designed for longevity with a 3 year warranty
on premium efficient Super-E® Motors
• Suitable for Inverter use per NEMA MG1
Part 31.4.4.2
Explosion Proof
Motors
1 thru 20 Hp
Pump Motors
Close-Coupled Pump, Three Phase, Foot Mounted,
With Internal Aegis® Bearing Protection Ring
HVAC Motors
Pump Motors
Farm Duty
Motors
■ Cast Iron Frame
For more information visit baldor.com
­121
1 1/2
2
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
3
5
7 1/2
10
15
20
25
30
40
50
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
56
143T
145T
143T
145T
182T
145T
145T
184T
145T
182T
182T
213T
184T
184T
215T
213T
213T
254T
215T
215T
256T
254T
254T
284T
256T
256T
286T
284TS
284T
324T
286TS
286T
326T
324TS
324T
364T
326TS
326T
365T
(a) See notes on inside back flap.
Catalog
Number
EM3545-G
EM3546T-G
EM3556T-G
EM3550T-G
EM3554T-G
EM3607T-G
EM3555T-G
EM3558T-G
EM3614T-G
EM3559T-G
EM3610T-G
EM3611T-G
EM3704T-G
EM3613T-G
EM3615T-G
EM3708T-G
EM3709T-G
EM3710T-G
EM2276T-G
EM3711T-G
EM3714T-G
EM2332T-G
EM2394T-G
EM2333T-G
EM4100T-G
EM4106T-G
EM2334T-G
EM4102T-G
EM4107T-G
EM4103T-G
EM4111T-G
EM4108T-G
EM4104T-G
EM4117T-G
EM4109T-G
EM4110T-G
EM4308T-G
EM4114T-G
EM4115T-G
EM4312T-G
■ Cast Iron Frame
List
Price
Mult.
Sym.
796
872
1,012
892
900
1,186
961
927
1,234
1,037
1,079
1,037
1,570
1,175
1,116
1,745
1,686
1,547
2,842
1,706
1,718
3,202
2,813
2,599
4,257
3,059
3,089
5,543
3,986
4,034
6,301
4,665
4,715
7,209
6,333
6,129
9,257
6,885
6,655
11,010
K
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
“C”
Dim.
230/460 Volt
12.23
12.31
13.31
12.29
13.31
16.54
13.29
13.31
18.04
14.17
15.29
16.54
19.01
16.54
18.04
19.76
17.89
19.01
23.30
17.89
20.51
23.30
23.30
23.30
27.76
23.30
23.30
27.76
24.70
27.76
30.39
24.70
27.76
30.28
28.78
30.28
33.48
28.78
30.28
33.48
Aprx.
Wt. (lb)
Full Load
Efficiency
Voltage
Full Load
Amps
Notes (a)
32
30
43
36
42
76
46
42
94
53
57
74
135
76
92
154
133
129
281
118
156
322
239
270
369
261
295
393
323
400
507
336
410
604
532
596
883
584
648
910
77
85.5
82.5
84
86.5
87.5
85.5
86.5
88.5
86.5
86.5
89.5
89.5
88.5
89.5
89.5
89.5
91.7
91
90.2
91.7
91
91
92.4
91.7
91
93
91.7
91.7
93.6
93
91.7
93.6
93
92.4
94.1
94.1
93
94.5
94.1
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
1.4
1.5
1.8
1.9
2.2
2.4
2.5
2.9
3.5
3.6
3.6
4.2
4.6
5.9
6.7
7.3
9
9.4
11
11.8
12
14.1
17.5
18.1
21
23
24
27
29
30
32
34
38
39
46
48
49.4
56
58
61.7
12, 30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
For more information visit baldor.com
General
Information
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
NEMA
Frame
Large AC
Motors
1
RPM
Washdown Duty
Motors
Hp
Applications:
• Fans
• Pumps
• Blowers
• Unit Handling
• HVAC Systems
• Variable Speed Applications
• General Purpose Applications
Explosion Proof
Motors
Features:
• Class H insulation for increased
protection on inverter use
• Internal grounding ring for bearing
current mitigation on DE retainer ring
• Designed for longevity with 3 year
warranty
• Suitable for inverter use per NEMA
MG1 Part 31.4.4.2
Pump Motors
1 thru 100 Hp
HVAC Motors
Super-E®, Three Phase, TEFC, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring
Farm Duty
Motors
HVAC Motors
­139
General
Information
HVAC Motors
Super-E®, Three Phase, TEFC, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring
RPM
NEMA
Frame
100
3600
1800
3600
1800
1800
364TS
364T
365TS
365T
405T
EM4310T-G
EM4314T-G
EM4313T-G
EM4316T-G
EM4400T-G
9,875
9,763
11,350
11,273
14,152
5
7 1/2
10
15
1800
1800
1800
1800
184T
213T
215T
254T
EM3665T-8G
EM3770T-8G
EM3774T-8G
EM2333T-8G
1,350
1,725
1,908
2,599
1
1 1/2
2
3
5
7 1/2
10
15
20
25
30
40
50
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
143T
145T
145T
182T
184T
213T
215T
254T
256T
284T
286T
324T
326T
EM3546T-5G
EM3554T-5G
EM3558T-5G
EM3611T-5G
EM3615T-5G
EM3710T-5G
EM3714T-5G
EM2333T-5G
EM2334T-5G
EM4103T-5G
EM4104T-5G
EM4110T-5G
EM4115T-5G
872
900
927
1,037
1,116
1,547
1,718
2,599
3,089
4,034
4,715
6,129
6,655
Hp
Single Phase
Motors
60
75
Catalog
Number
List
Price
Mult.
Sym.
“C”
Dim.
Aprx.
Wt. (lb)
General Purpose
Industrial Motors
Severe Duty
Motors
Large AC
Motors
Washdown Duty
Motors
230/460 Volt continued
L1
31.36
900
L1
33.48
907
L1
31.36
966
L1
33.48
956
L1
38.20
1214
200 Volt
L1
15.23
119
L1
18.45
170
L1
18.45
231
L1
23.30
254
575 Volt
L1
12.31
35
L1
13.31
42
L1
13.31
46
L1
16.54
76
L1
18.04
84
L1
19.01
126
L1
20.51
165
L1
23.30
250
L1
23.30
293
L1
27.76
364
L1
27.76
423
L1
30.28
576
L1
30.28
644
(a) See notes on inside back flap.
■ Cast Iron Frame
Explosion Proof
Motors
Pump Motors
HVAC Motors
Farm Duty
Motors
­140
For more information visit baldor.com
Full Load
Efficiency
Voltage
Full Load
Amps
Notes (a)
95
95
94.5
95.4
95.4
230/460
230/460
230/460
230/460
230/460
66.3
68
81.9
85.9
112
30
30
30
30
30
89.5
91.7
91.7
92.4
200
200
200
200
15.1
21.4
28
42.4
85.5
86.5
86.5
89.5
89.5
91.7
91.7
92.4
93
93.6
93.6
94.1
94.5
575
575
575
575
575
575
575
575
575
575
575
575
575
1.2
1.8
2.3
3.3
5.3
7.6
9.6
14.6
19.2
24
29
39
46
1 1/2
2
3
5
7 1/2
10
15
20
25
30
40
50
60
75
100
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1200
3600
1800
1800
1800
1800
56
143T
145T
143T
145T
182T
143T
145T
184T
145T
182T
213T
182T
184T
215T
184T
213T
254T
213T
215T
256T
215T
254T
284T
254T
256T
286T
256T
284T
324T
284TS
286T
326T
286TS
324T
364T
324TS
326T
364T
365T
404T
Catalog
Number
EM31115-G
EM3116T-G
EM3156T-G
EM3120T-G
EM3154T-G
EM3207T-G
EM3155T-G
EM3157T-G
EM3215T-G
EM3158T-G
EM3211T-G
EM3305T-G
EM3212T-G
EM3218T-G
EM3309T-G
EM3219T-G
EM3311T-G
EM2506T-G
EM3312T-G
EM3313T-G
EM2511T-G
EM3314T-G
EM2513T-G
EM2524T-G
EM2514T-G
EM2515T-G
EM2528T-G
EM2516T-G
EM2531T-G
EM2532T-G
EM2534T-G
EM2535T-G
EM2536T-G
EM2538T-G
EM2539T-G
EM2540T-G
EM2542T-G
EM2543T-G
EM2547T-G
EM2551T-G
EM2555T-4G
List
Price
Mult.
Sym.
703
877
893
778
909
1,048
884
962
1,067
893
1,055
1,328
991
1,137
1,672
1,456
1,602
2,032
1,661
1,893
2,556
2,266
2,660
3,428
2,695
2,890
4,090
3,177
3,543
4,941
3,781
3,839
5,134
4,762
4,972
7,170
5,232
5,439
7,117
8,543
10,158
K
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
“C”
Dim.
230/460 Volt
11.75
11.12
11.62
11.12
11.62
15.00
11.62
12.12
16.50
13.00
15.00
16.32
13.62
16.50
17.45
15.00
16.32
23.19
16.32
17.45
23.19
16.32
21.69
23.81
21.69
21.69
23.81
21.69
25.06
27.69
22.44
25.06
28.69
22.44
27.19
30.69
25.69
27.69
30.69
33.72
36.97
Aprx.
Wt. (lb)
Full Load
Efficiency
Voltage
Full Load
Amps
27
34
40
34
38
67
41
41
79
46
72
110
63
84
141
75
115
243
113
127
255
126
210
280
195
227
299
212
314
384
310
340
457
328
392
606
392
473
616
750
898
77
85.5
82.5
84
86.5
86.5
85.5
86.5
87.5
85.5
89.5
88.5
86.5
89.5
89.5
88.5
91
90.2
89.5
91.7
91.7
90.2
93
91.7
91
93
92.4
91.7
93.6
93
91.7
94.1
93.6
92.4
94.1
94.1
93
94.5
95
95
95.4
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
230/460
460
1.6
1.5
1.8
2
2.2
2.5
2.5
2.9
3.4
3.8
4.2
4.5
6
6.6
7.4
8.6
9.7
11
12
12.5
14.3
17.5
17.7
20.5
23.5
23.5
27
28
30
34
35
35
38
46
49
51
56
57
68
87
115
(a) See notes on inside back flap. Red Catalog Number indicates NEW Product.
For more information visit baldor.com
Notes (a)
12, 15, 30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
General
Information
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
NEMA
Frame
Large AC
Motors
1
RPM
Washdown Duty
Motors
Hp
Applications:
• Fans
• Pumps
• Blowers
• Unit Handling
• HVAC Systems
• Variable Speed Applications
• General Purpose Applications
Explosion Proof
Motors
Features:
• Class H insulation for increased
protection on inverter use
• Internal grounding ring for bearing
current mitigation on DE retainer ring
• Designed for longevity with 3 year
warranty
• Suitable for inverter use per NEMA
MG1 Part 31.4.4.2
Pump Motors
1 thru 100 Hp
HVAC Motors
Super-E®, Three Phase, ODP, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring
Farm Duty
Motors
HVAC Motors
­141
General
Information
HVAC Motors
Super-E®, Three Phase, ODP, Foot Mounted,
with Internal AEGIS® Bearing Protection Ring
Single Phase
Motors
General Purpose
Industrial Motors
Severe Duty
Motors
Large AC
Motors
Washdown Duty
Motors
Hp
RPM
NEMA
Frame
1
1 1/2
2
3
5
7 1/2
10
15
20
25
30
40
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
143T
145T
145T
182T
184T
213T
215T
254T
256T
284T
286T
324T
1
1 1/2
2
3
5
7 1/2
10
15
20
25
30
40
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
1800
143T
145T
145T
182T
184T
213T
215T
254T
256T
284T
286T
324T
Catalog
Number
List
Price
Mult.
Sym.
EM3116T-8G
EM3154T-8G
EM3157T-8G
EM3211T-8G
EM3218T-8G
EM3311T-8G
EM3313T-8G
EM2513T-8G
EM2515T-8G
EM2531T-8G
EM2535T-8G
EM2539T-8G
877
909
962
1,055
1,137
1,602
1,893
2,660
2,890
3,543
3,839
4,972
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
EM3116T-5G
EM3154T-5G
EM3157T-5G
EM3211T-5G
EM3218T-5G
EM3311T-5G
EM3313T-5G
EM2513T-5G
EM2515T-5G
EM2531T-5G
EM2535T-5G
EM2539T-5G
877
909
962
1,055
1,137
1,602
1,893
2,660
2,890
3,543
3,839
4,972
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
“C”
Dim.
200 Volt
11.12
11.62
12.12
15.00
16.50
16.32
17.45
21.69
21.69
25.06
25.06
27.19
575 Volt
11.12
11.62
12.12
15.00
16.50
16.32
17.45
21.69
21.69
25.06
25.06
27.19
Aprx.
Wt. (lb)
Full Load
Efficiency
Voltage
Full Load
Amps
38
37
43
74
92
120
132
234
250
330
340
390
85.5
86.5
86.5
89.5
89.5
91
91.7
93
93
93.6
94.1
94.1
200
200
200
200
200
200
200
200
200
200
200
200
3.5
5.1
6.5
9.7
15.3
22.2
29.5
40.7
54.3
70
81
109
38
37
43
74
92
114
132
210
250
328
340
400
85.5
86.5
86.5
89.5
89.5
91
91.7
93
93
93.6
94.1
94.1
575
575
575
575
575
575
575
575
575
575
575
575
1.2
1.8
2.3
3.4
5.3
7.8
10
14.1
18.9
24.5
28
40
(a) See notes on inside back flap.
Explosion Proof
Motors
Pump Motors
HVAC Motors
Farm Duty
Motors
­142
For more information visit baldor.com
Notes (a)
Baldor
Mod Express
ABB
Mod Express
ABB ATEX
Mod Express
Product
Index
Baldor
Sales Offices
­378
Baldor Mod Express
Modification
Motor Mod Express®Page
Number
No.
Shaft Modifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
M29A
Drill and Tap or Flat
M29B
Convert from TEFC to TEAO
M29C
Threading
M29D
Convert “T” Frame to “U” Frame Shaft Dimension or Smaller (TS)
M29F
Shorten Shafts without Reducing the Overall Dimension
M29I
Machine Explosion Proof Motor Shafts from T to a U Frame
M29J
Convert “L” Frame shaft to Shorter Shaft for Coupled Duty
Grounding Screws
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405
M30A
Add Grounding Screw on Endplate
Tach and Encoder Mounting Kits
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406
M31A
Add Tach Mounting Kits to DC Motors
M31B
Add Tach Mounting Kits with BTG1000 Tach
M31C
Add Tach Mounting Kits with XPY Tach
M31D
Add Encoder Kit to Inverter Duty V*S Master or RPMAC Motor
M31E
Additional Mounted Encoder Option for IDRPM Motors
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
M32A
Performance Testing Per IEEE 112
M32B
Witnessed IEEE 112 Performance Testing
Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 407
M33A
Short Motor Test
M33B
Routine Motor Test
M33C
Complete Motor Test
M33D
Calibration Test
M33E
Sound Measurement Test
Worm Gear Modifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409
M34A
Install Bases on Worm Gear Speed Reducers
M34B
Convert From Single to Double End Output Shaft on Worm Gear Speed Reducers
M34C
Convert Output Shaft from Left Hand to Right Hand or Vise Versa on 900 or Universal Series Reducers
M34D
Install Motor on 900 F-Series or Universal STF-Series Reducers
Terminal Blocks (50 Hz, 3 Phase Motors Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
M35A
Install Terminal Blocks in Conduit Box and Connect Leads
Starters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
M36A
Add Magnetic or Manual Starter to Grinder or Buffer – Starter – Single Phase
M36B
Add Magnetic or Manual Starter to Grinder or Buffer – Starter – Three Phase
M36C
Add Magnetic or Manual Starter to Grinder or Buffer – Magnetic Starter – Three Phase
M36D
Overload Protection for Dust Control Unit
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
M37A
Change a Grinder Dust Control Unit to a 575 Volt
M37B
NEW! Reconnect Grinder for 230V and change to 230V relay
Shaft Grounding
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
M39A
Shaft Grounding Systems
M39B-1
AEGIS® Bearing Protection Ring
M39B-2
Inpro/Seal® Current Diverter Ring™
M39B-3
Inpro/Seal® Motor Grounding Seal™
M39C
Baldor Shaft Grounding Brush Assembly
Check Total Indicated Runout (TIR)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
M40A
Check Total Indicated Runout (TIR)
Vibration Detectors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
M41A
Provisions for Vibration Detection
M41B
Add Vibration Switch
M41C
Add Velocity Transducer
M41D
Add Accelometer
Cast Iron Endplate
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
M42A
Install Cast Iron Endplate
For more information visit baldor.com
Motor Mod Express®
Description and List Price
Working Days
Required
ABB
Mod Express
Shaft Grounding
ABB ATEX
Mod Express
A shaft ground may be specified by many HVAC, pump and conveyor
manufacturers to mitigate the effects of Adjustable Speed Drive circulating
currents and prolong bearing life. Shaft grounding is available as an option on
Baldor•Reliance custom motors or can be installed on a stock motor in Baldor’s
Mod Express. On applications where washdown or debris may be present,
mounting the ground internally on the motor (as custom) may be required.
NOTE: A shaft ground is a sparking device not suited for explosion-proof Division 1 or 2
applications, even when mounted internally.
M39A
Shaft Grounding Systems
The SGS™ (Shaft Grounding Systems) design
is a robust, enclosed unit designed for harsh
environments. Mounts to the opposite drive
end of the motor on TEFC, TENV, TEBC & ODP
motors.
Product
Index
Baldor offers three main types of shaft grounding devices:
• M39A - Shaft Grounding Systems
• M39B - Shaft Grounding Rings
• M39C - Shaft Grounding Brush
THREE
DAYS
NEMA Frame
List Price
56 - 449T
1231
Baldor
Sales Offices
Modification
Number
Baldor
Mod Express
Baldor Mod Express
Does Not Apply to Explosion-Proof or Division 2 Motors
M39B-1AEGIS® Bearing Protection Ring
NEMA Frame
56
140T, 180
180T, 210
210T, 250U
250T, 280U
280T, 320U, 320TS, 360TS
320T, 360U, 400TS
360T, 400U, 440TS
400T, 440U
440T
Shaft Diameter
0.625
0.875
1.125
1.375
1.625
1.875
2.125
2.375
2.875
3.375
List Price
221
232
244
258
322
343 (1)
379 (1)
456 (1)
643 (1)
766 (1)
(1)Motors over 100 Hp / 75 kW require an additional modification to add an insulated bearing on the opposite drive
end. Reference Mod M2F to add for one insulated bearing on the ODE of the motor.
NOTE: For this modification, the AEGIS Bearing Protection Ring mounts to the drive end of the motor.
For more information visit baldor.com
­413
Download