Digital Protective Relays Larsen & Toubro Larsen & Toubro is a technology-driven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction, Electrical & Automation, Machinery and Information Technology. L&T Switchgear, a part of the Electrical & Automation business, is India's largest manufacturer of low voltage switchgear, with the scale, sophistication and range to meet global benchmarks. With over five decades of experience in this field, the Company today enjoys a leadership position in the Indian market with a growing international presence. It offers a complete range of products including powergear, controlgear, industrial automation, building electricals & automation, reactive power management, energy meters, and protective relays. These products conform to Indian and International Standards. L&T limited offers a wide range of Microprocessor based State-of-the-art digital protective relays suitable for LV, MV and HV power distribution systems. These relays are manufactured at L&T’s Mysore works equipped with modern infrastructure and employing latest manufacturing and testing equipments. L&T’s range also include relays for special applications manufactured by Microelettrica Scientifica, Italy. The applications include Feeder Management, Load Sharing, Load Shedding, Synchronising, Grid Islanding etc. L&T also manufactures a range of electronic single phase energy meters, three phase energy meters and trivector meters at the Mysore works. Switchgear Factory, Mumbai Contents Pages ANSI / IEEE Device Function Number Details 1 Time - Current Characteristics 2 Over Current Relays & Earth Fault Relays - MC31A, MC61A, MC61C 3 Current Sensing Relays - MC12A, ME12A, SC14S 5 Reverse Power Relay - MRP11 7 Voltage Relay - MV12 Power Factor Control Relays - etaCON Series RPM14, RPM08 9 11 Motor Protection Relays - MM30, MM30W, N-DIN-MA MCOMP, MPR300 13 15 Generator Protection Relays - MG30, MG30I, MD32G 17 Transformer Protection Relays - IM30T, MD32T, MD32TM 19 Feeder Protection Relays - MC20, MC30 21 Vector Surge Protection Relay - UM30A, FMR 23 Control & Supervision Relays - MW33 Synchronising Load Sharing Relays - SPM21, RRS 25 Voltage and Frequency Relays - MC1V, MC3V, UFD34 27 Schematic - Relay Application 29 ANSI/IEEE Correlation between ANSI/IEEE device function number and relays Device No. Function Name 21 25 27 Under impedance relay / Distance relay Auto synchronising Synchro-check relay AC under voltage relay 32 37 Power directional relay Under current or under power relay 40 45 46 Field control (loss of field) relay DC over voltage relay Reverse phase or phase balance current relay 47 49 Phase-sequence or single-phasing voltage relay Machine or transformer thermal relay 50 Instantaneous over current (or rate-of-rise) relay L&T Relays MV12 MRP11 MPR300 ME12 MC12A MC61A / MC61C 51V, 50V 50BF 50N Voltage restrained over current relay Breaker - failure Instanteneous earth fault over current relay 51 AC time over current relay 51N-(51G) Ground fault time over current relay 58 59 Rectifier failure relay (rotating diodes) AC over voltage relay 59/81 60 64 64S 64R 67 67N-(67G) 76 78 79 80 81 Overexcitation relay V/Hz Voltage balance relay Ground detector (insulation to ground failure of machine or other apparatus) Machine stator ground fault detector relay -Machine rotor ground fault detector relay -AC directional over current relay -Directional ground fault over current relay -DC over current relay – Phase angle measuring or out of-step protection relay – Reclosing relay -DC under voltage relay -Frequency relay – -Lock-out relay -Differential protective relay SC14S -Ground fault differential protective relay – Regulating device to adjust a quantity – Automatic active or reactive load sharing relay – Vector surge protection relay Rate of change of frequency – 86 87 87N-(87G) 90 95 df/dt 1 MC12A MC61A MC61C MC12A MC61A MC31A MC61C MC12A MC61A MC31A MC61C – MV12 --- MS Relays MG30 / MG30-I SPM21 SCM21 UM30-A / MC1V / MC3V UFD34 MG30 / MW33 / MG30-I MM30 MW33 MG30 / MG30-I UBC / 45 IM30T MM30 UM30-A, MC3V IM30T MG30 / MG30-I MM30 / MM30-W MC20 / MC30 IM30-T / IM30-AP FMR MG30 / MG30-I MG30 / MG30-I MC20 / MC30 / FMR / IM30T / IM30AP IM30 AP / IM30-T MC20 / MC30 FMR / IM30-T IM30-AP / IM30-T MC20 / MC30 FMR / IM30-T -IM30-AP / IM30-T MC20 / MC30 FMR -RHS -UFD34, MW33 UM30-A / MG30 / MG30-I UM30-A MG30 MG30 UBO / CR FMR FMR – IM30-GOS MC20R UBC / 80 UM30-ASV / MG30 UFD34 / MC1V / MC3V / MW33 -MD32G MD32T / MD32TM MD32G, MD32T -RRS UM30-A UFD34 Time - Current Characteristics Product Design Standards Reference standards Dielectric test Impulse test HF disturbance test Electrostatic discharge test Electrical fast transient Radiated electro magnetic field test Surge immunity Ring wave test Voltage dips & interruption test Power frequency magnetic test : : : : : : : : : : : IEC 60255, IEC 61000, IS3231, IS8686 IS 3231 / IEC 60255-5 IS 8686 / IEC 60255- 5 IS 8686 / IEC 60255-22-1 IEC 61000-4-2 IEC 61000-4-4 IEC 61000-4-3 IEC 61000-4-5 IEC 61000-4-12 IEC 61000-4-11 IEC 61000-4-8 Time - Current Characteristics (At TMS = 1) 1,000 Trip Time (Sec.) 100 10 A 1 B C D 01 1 10 20 Multiple of set current (Is) For Trip time at TMS other than 1 Trip time = (Trip time at TMS = 1) x TMS or 50 msec whichever is more. A : Normal Inverse 3.0 sec B : Normal Inverse 1.3 sec C : Very Inverse D : Extreme Inverse 2 Over Current and Earth Fault Relays • Three phase over current & earth fault relays Salient Features • Display of currents, settings, Trip data & Trip history for analysis & trouble shooting • Built in self supervision & self testing feature to ensure continuous reliability • Separate indication for power ON & programming mode on relay fault • Separate fault indication • In MC61C - Communication with computer & breaker control through RS485 Port • Four user programmable output relays Model MC31A Description 3 Phase O/C + E/F MC61A MC61C 3 Phase O/C + E/F + Highset Communication and breaker control Device code 50/51 RYBN 51 RYBN 50/51 RYBN Design Numerical relay Numerical relay Numerical relay Lowset O/C - Is Lowset O/C - Is Lowset O/C - Is Highset O/C - Ihs Lowset E/F - Os Highset O/C - Ihs Functions available Lowset E/F - Os Lowset E/F - Os Highset E/F - Ohs Highset E/F - Ohs O/C Is = 20-200% step 5% O/C Is = 20-200% step 5% O/C Is = 20-200% step 5% E/F Os = 5-80% step 5% E/F Os = 5-80% step 5% E/F Os = 5-80% step 5% HS O/C = (0.2 to 40) x in step of - HS O/C = (0.2 to 40) x in step of Time characteristics available 0.2 in or disable 0.2 in or disable NI, VI, EI, definite time Settings HS E/F = (0.1 to 20) x on step of - HS E/F = (0.1 to 20) x on step of TMS 0.1 - 1.6 step 0.05 0.1 on or disable 0.1 on or disable Time characteristics available Time characteristics available NI, VI, EI, definite time NI, VI, EI, definite time TMS : 0.1 - 1.6 step 0.05 TMS : 0.1 - 1.6 step 0.05 HS delay:0.1-2 sec step 0.01 Site selectable trip time char. Site selectable trip time char. sec or inst. RS485 communication Highset can be disabled Other features Breaker control Display of currents, trip count Display of currents, trip count Auto doubling of highset, Self supervision feature Self supervision feature Relay co-ordination - BI & BO Burden on CT ≤ 0.25 VA on CT/Phase ≤ 0.25 VA on CT/Phase ≤ 0.25 VA on CT/Phase Burden on PT Not applicable Not applicable Not applicable Operating temp 00C to 600C 00C to 600C 0 0C to 600C Weight < 2kg < 2kg < 2kg Burden on auxiliary supply ≤ 10 VA ≤ 10 VA ≤ 10 VA Output contact 1 N/O Contact for self supervision 1 N/O Contact for self supervision 1 N/O Contact for self supervision, 1N/O for trip Construction Drawout Drawout Drawout 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224 Dim W x H x D in mm 113 x 142 113 x 142 113 x 142 Panel cutout Ordering Information 20-110 V AC / DC or 20-110 V AC / DC or Auxiliary supply Type 1 20-110 V AC / DC or 88-264 V AC / DC Type 2 88-264 V AC / DC 88-264 V AC / DC 1 A or 5 A 1 A or 5 A 1 A or 5 A CT Rating (not site selectable) (site selectable) (site selectable) 4 NO 4 NO or 2 NO + 2 NC 4 NO or 2 NO + 2 NC Output contacts 3 3 Phase O/C + E/F + Highset Wiring Diagrams MC31A R Y B 1 R Y B 1 2 2 3 3 4 4 13 13 5 5 6 6 MICRO CONTROLLER N0 R1 9 MC31A PROTECTION 10 NC R2 11 12 F50(Is) R3 F51(0s) 15 15 16 16 7 7 8 8 17 18 R4 27 R Y B E 28 21 R5 22 In = 0n = 1A; 1A; L/+ 5A 5A N/- 26 29 PROG. ERROR 25 30 ˜ MC61A R Y B R Y B 1 1 2 2 3 3 4 4 13 13 5 5 6 6 MICRO CONTROLLER R1 N0 9 MC61A PROTECTION 10 NC R2 11 12 F50(Is) 15 15 16 16 7 7 8 8 R3 F51(Os) 17 F50(Ihs) 18 F51(Ohs) R4 27 R Y B E 28 21 R5 22 In = 1A; 5A 0n = 1A; 5A L/+ N/- 29 PROG ERROR 25 30 26 MC61C R Y B R Y B 1 1 2 2 3 3 4 4 R1 9 MICRO CONTROLLER 10 R2 MC61C PROTECTION 13 13 5 5 6 6 F51(Os) 15 15 F50(Ihs) 16 16 F51(Ohs) 7 7 8 8 F50(Is) 12 R3 17 R4 Y B E D2 D3 In = 0n = 1A ; 1A ; 5A 5A L/+ PROG ERROR 25 ˜ N/- 26 18 OPEN 27 BKR 28 CLOSE 29 21 22 NC BKR R5 D1 R NO 11 C 30 19 L/R 20 BI* 31 32 SS+ 9 PIN MALE 4 Current Sensing Relays • Single phase over current / earth fault relay • Sensitive E/F relay / instantaneous current relay Salient Features • Easy setting through front panel DIP switches • Indication for power ON and trip status • Test feature - helps in better maintenance • Compact, light weight helps in reducing panel size & thickness Model MC12A ME12A SC14S Description Device code Design 1 Ph O/C or E/F 50/51 or 50N/51N Microcontroller based Lowset O/C - Is Highset O/C - Ihs Lowset E/F - Os Highset E/F - Is O/C Is = 50-200% Step 10% or E/F Is = 10-40% Step 2% or E/F Is = 20-80% Step 4% HS O/C = (2-16) xls step 2 Is HS E/F = (2-16) xls step 2 Is Time characteristics availableNl, VI, EI, Definite time 3 ranges of def time (1, 10,100) TMS : 0.1 - 1.6 Step 0.1 Site selectable trip time char. Highset can be disabled 1 Ph Sensitive E/F 50N/51N Microcontroller based Lowset S E/F - Is Highset S E/F - Ihs Instantaneous current relay 87N/64R Static S E/F = 1-16% step 1% HS S E/F = (2-16) xls in steps of 2 ls Is = 10-40% step 5% or 20-80% step 10% Functions available Settings Other features Burden on CT Burden on PT Operating temp Weight Burden on auxiliary supply Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply CT Rating Range setting 5 Type 1 Type 2 Time characteristics availableNI, VI, EI, Definite Time 3 ranges of def Time (1, 10, 100) TMS : 0.1 - 1.6 Step 0.1 Site selectable trip time char. Highset can be disabled Harmonic rejection 0.25 VA on CT 0.25 VA on CT Not applicable Not applicable 00C - 600C 00C to 600C < 1.5kg < 1.5kg 5.5 VA 5.5 VA 2 C/O Contacts (S/R) 2 C/O Contacts (S/R) Drawout Drawout 71 x 158 x 224 71 x 158 x 224 62 x 142 62 x 142 Ordering Information 20-110 V AC / DC or 20-110 V AC / DC or 88-264 V AC / DC 88-264 V AC / DC 1 A or 5 A 1 A or 5 A 10-40% or 20-80% or 50-200% Site selectable Time characteristics availableInstantaneous (25ms) or time delayed 100ms / 200ms Self powered Relay testing possible by ext. 24 V Supply Flag indication / LED indication 6 VA Not applicable 00C to 600C < 1.5kg Not applicable 2 C/O Contacts (S/R) Drawout 71 x 158 x 224 62 x 142 Not applicable 1 A or 5 A 10-40% or 20-80% Wiring Diagrams MC12A / ME12A COM 1 2 +VE/PH. Aux. Supply 3 -VE/N R1 μP. Control Ckt. F50/50N F51/51N 10 COM 11 12 MC12A / ME12 SETTING RANGE (Is) In AUX SUPPLY 24 - 110V AC/DC 95 - 240V AC/DC 1A 5A ME12 (1-16)% In MC12A (10-40)% In (20-80)% In (50-200)% In SC14S 11 2 10 ˜ 9 1 Control Ckt. R 3 7 + 5 DC-DC Test (24V) Voltage Test 6 Convrt. 8 4 12 SC14S In 1A 5A CT OPERATED RELAY NO AUXILIARY SUPPLY REQUIRED SETTING RANGE (Is) (10-40)% IN (20-80)% IN 6 Reverse Power Relay, Under Voltage or Over Voltage Relay Salient Features • Easy setting through front panel DIP switches • LED indication for power ON and trip status • Test feature - helps in better maintenance • Compact, light weight helps in reducing panel size & thickness Model MRP11 MV12 Description Device code Design Reverse power 32 Microcontroller based Reverse power level 1 Ph U/V or O/V 27 or 59 Microcontroller based Lowset U/V - Vs Lowset O/V - Vs U/V Vs = 95-20% step 5% O/V Vs = 105-180% step 5% Time characteristics availableInverse time, definite time TMS : 0.1 - 1.6 Step 0.1 Functions available Settings Other features Burden on PT Burden on CT Operating temp Weight Burden on auxiliary supply Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply CT Rating PT Rating 7 Type 1 Type 2 PT input Vn 110 V, 415 V AC CT input In 1 A / 5 A Pick up level 1% - 15% Min. setting 0.5% TMS 0 to 1.5 step 0.1 Definite time characteristics LED indication Test feature < 0.25 VA < 0.05 VA 00C to 600C < 1.5kg < 8 VA 1 N/O + 1 C/O Drawout 71 x 158 x 224 62 x 142 Ordering Information 20-110 V AC / DC 88-264 V AC / DC 1 A or 5 A Upto 380 V AC Site selectable U/V or O/V Site selectable trip time char. < 0.25 VA 0.075 VA on PT 00C to 600C < 1.5kg 8 VA 2 C/O Contacts (S/R) Drawout 71 x 158 x 224 62 x 142 20-110 V AC / DC 88-264 V AC / DC Not applicable 110 V / 240 V / 415 V (site selectable) Wiring Diagrams MRP11 1 R Y B 4 2 + VE / PH. 3 Aux. Supply – VE / N 5 R1 μP. Control Ckt. F32 11 7 8 12 6 9 10 MRP11 Vn 110 V AC 415 V AC In AUX SUPPLY 24–110 V AC/DC 95–240 V AC/DC 1A 5A MV12 1 5 2 4 3 +VE/PH. Aux. Supply 4 -VE/N R1 μP.Control Ckt. F27 F59 6 8 11 9 12 7 MV12 8 Power Factor Control Monitoring Relays • Intelligent Power factor controllers with Automatic set-up and TTL/RS232 Port Ne Salient Features w • Auto / Manual mode • Measurement Sensitivity - 2.5% 096 • 4 Quadrant / 2 Quadrant operation • Automatic recognition of current flow direction • Online display of PF, Voltage, Current, kVAr, capacitor overload and Panel temperature • The last two contacts are programmable as alarm and / or fan control except for etaCON 3 • Capacitor over-current and panel over-heating protection etaCON Series • Use in co-generation systems - 4 Quadarant operation Inbuilt Controller Set-up feature provides an option of Automatic configuration of etaCON controller. TTL / RS232 Communication port to interface with PC for quick set-up, function and alarm customising and testing. etaCON L series APFC relay Product Model No.of steps Design Display Current Input Voltage Input Rated Frequency etaCON L3; etaCON L5; etaCON L7 3, 5, 7 Instantaneous PF, V, I, kVAr, Capacitor Over load Panel temperature, Average weekly PF, Maximum Voltage, current, capacitor overload, panel temperature value Measurement Setting Target PF adjustment: 0.8 inductive to 0.8 capacitive Reconnection time of same capacitor: 5 - 240 secs Switching time sensitivity: 5 - 600 secs Alarms Under/ Over compensation; Low/ High Current; Low/ High Voltage; Capacitor Overload due to harmonic Voltage; Over temperature; No-voltage release Power consumption Burden on CT Dimensions W x H x D in mm 96 x 96 x 96 mm Panel cutout 92 x 92 mm Voltage Input CT Input No.of steps 9 etaCON L8; etaCON L12 8, 12 Digital Microprocessor based 3 Digit LED 5 Amp 415 VAC ± 15% 50/ 60 Hz 415 V AC 5 A secondary 3; 5; 7 steps Less than 10 VA Less than 0.8 VA 144 x 144 x 93 mm 138.5 x 138.5 mm Ordering Information 415 V AC 5 A secondary 8; 12 steps Wiring Diagrams etaCON L3/L5/L7 MAINS L1L2 L3 1 2 3 4 5 6 7 1 2 3 4 5 6 7 8 Voltage Current 415V /5A 9 S1 S2 10 C FU11 CT1 OS1 FU2 FU1 FU8 FU9 FU7 FU10 KM1 KM2 KM7 LOAD K1 K7 K2 etaCON L8/L12 MAINS L1L2 L3 Current /5A S1 S2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 9 10 11 12 Voltage 415V 15 16 C CT1 FU16 OS1 FU1 FU13 FU14 FU12 FU2 FU15 KM1 KM2 KM12 LOAD K1 K2 K12 10 Power Factor Control Monitoring Relays • (8 & 14 Stages) Intelligent power factor controller relay Salient Features • On line display of system PF • Easy setting through - front panel push button • Suitable for non-uniform banks • LED indication for alarm code, no. of banks selected, PF status-lead / lag / unity • Auto / Manual mode • Measurement sensitivity of 1% • Automatic C/K correction • Display of Current, Voltage, kVAr, & Capacitor values Model RPM-8 RPM-14 Description Automatic power factor controller 8 stage Automatic power factor controller 14 stage Microcontroller based Automatic PF control upto 8 stage Switching time 1-255 sec in step of 1 sec for same Bank switching Auto C/K selection PF control range 1% to 120% of rated current Can accept unequal banks Display of PF, V, l, kVAr LED indications for faults Alarm signal for CT reversal, under current, under compensation, over compensation, over voltage, 1 A / 5 A field selectable 0.3 VA 15 VA 00C to 600C < 2kg 8 N/O 1 N/O contact for alarm 144 x 144 x 100 138 x 138 Ordering Information 240 V AC Microcontroller based Automatic PF control upto 14 stage Switching time 1-255 sec in step of 1 sec for same Bank switching Auto C/K selection PF control range 1% to 120% of rated current Can accept unequal banks Display of PF, V, l, kVAr LED indications for faults Alarm signal for CT reversal, under current, under compensation, over compensation, over voltage, 1 A / 5 A field selectable 0.3 VA 15 VA 00C to 600C < 2kg 14 N/O 1 N/O contact for alarm 144 x 144 x 100 138 x 138 Device code Design Functions available Settings Other features Burden on CT Burden on PT Operating temp Weight Output contacts Dim W x H x D in mm Panel cutout Auxiliary supply 11 240 V AC Wiring Diagrams RPM-8 Ph 230V AC 1 13 2 14 3 15 ALARM 4 5 6 S1(5A) 7 S1(1A) 8 S2 9 + + - 50 Hz N 16 R8 17 R7 18 R6 19 R5 20 R4 21 10 R3 22 11 R2 23 12 R1 24 Bank #8 Bank #1 R Y To Load B N RPM-14 Ph 240V AC 1 R13 R2 2 R14 R3 3 13 50 Hz N 14 15 - 16 S2 17 S1(1A) 18 S1(5A) R4 4 R5 5 R6 6 R7 7 19 R8 8 20 + + R9 9 21 R10 10 22 R11 11 23 R12 12 24 Bank #1 ALARM R1 Bank #14 R Y B To Load N 12 Motor Protection Relay • Motor protection relay • Motor protection relay with voltage input Salient Features • Display of various parameters, trip count and trip data • LEDs for fault indication • User programmable output relays • Built in self supervision & self testing feature helps maintenance • RS485 Port for serial communication with “MSCOM” user friendly software Model MM30 Description Motor protection 50/51, 51LR, 64, 68, 49, 46, 37, St no, ltr Numeric Trip circuit supervision Thermal O/L and Pre-alarm Locked rotor Current unbalance, phase reversal, Phase loss Over current Earth fault Repeat and prolonged starts Restart inhibition No load running Blocking function MM30W Motor protection 50/51, 51LR, 64, 49, 46, 37, St no, Device code ltr, 55, 68, 81, 47, 12/14, 27/59 Design Numeric Trip circuit supervision Thermal O/L and Pre-alarm Locked rotor Current unbalance, phase reversal, phase loss Over current Earth fault Functions available Repeat and prolonged starts Restart inhibition No load running Blocking function Under frequency / Over frequency Under voltage / Over voltage Running hours Low PF Auto setting Auto setting 1 A or 5 A site selectable 1 A or 5 A site selectable (Default 5 Amp) (Default 5 Amp) Selectable motor time constant Selectable motor time constant Other features (1 - 60 min) (1 - 60 min) Display of parameters Display of parameters Built in self supervision Built in self supervision RS485 port RS485 port 0.2 VA for 5 A, 0.01 VA for 1 A 0.2 VA for 5 A, 0.01 VA for 1 A Burden on CT 0.04 VA Not applicable Burden on PT 100C to 600C 100C to 600C Operating temp < 2kg < 2kg Weight 8.5 VA 8.5 VA Burden on auxiliary 4 C/O + 1 C/O for self supervision 4 C/O + 1 C/O for self supervision Output contacts Drawout Drawout Construction 121 x 158 x 224 121 x 158 x 224 Dim W x H x D in mm 113 x 142 113 x 142 Ordering Information 20-110 V AC / DC or 20-110 V AC / DC or Auxiliary supply 88-264 V AC / DC 88-264 V AC / DC 13 N-DIN-MA Motor protection 49, 51LR, 46, 37, 50/51, 64, St no, Itr Numeric Thermal O/L and Pre-alarm Locked rotor Current unbalance, phase reversal, phase loss Over current Earth fault Repeat and prolonged starts Restart inhibition No load running Blocking function 2 Programable digital inputs 1 Removable front face panel LCD Display 1 A or 5 A site selectable (Default 5 Amp) Selectable motor time constant (1-60 min) Display of parameters Built in self supervision RS485 port, front RS232 port (on FFP) 0.075 VA for 5 A, 0.01 VA for 1 A Not applicable 100C to 600C < 1kg 3 VA 2 C/O contacts DIN rail mounting FFP = 106 x 45 x 16 RMB = 106 x 85 x 72 20-110 V AC / DC or 88-264 V AC / DC Wiring Diagrams MM30 A B A B C C 25 25 26 26 Microp. 27 27 MM30 28 39 29 28 39 29 41 30 32 43 41 30 32 43 ˜˜˜ 31 31 In=5A In=1A 42 42 33 33 Progr. R1 R3 8 18 20 R4 19 4 6 R5 5 15 17 R2 R3 L/+ 12 N/- ˜ 13 ˜= ˜ (10) N.O. N.C. N.C. 3 2 1 34/38 23 24 C SS+ Keyboard PRESA/TAP 31:Ion=5A PRESA/TAP 33:Ion=1A (21) N.O. 16 14 R4 R5 Int. Fault 44 11 22 7 9 R2 Function F37 F46 F49 F51 F51R F64 St.No.> AI.0> Itr 21 10 R1 Display 9 Pin Male IEC 255 N-DIN-M N-DIN-M A B A C 10 B A C B C 10 FFP Display / 10 11 11 11 8 8 8 9 9 9 Keyboard / Signals A B + 0 RS485 RMB RS485 A B + 0 N - DIN - M Functions F26 R1 16 F37 17 F46 12 12 12 13 13 13 F49 F51 BT 2 1 F51LR F64 Digital Input 1 Digital Input 2 T T 6 7 D1 D2 0 Thermistor Input C 2 Common 1 RTD 15 R2 St.Ctrl PWR / I.R.F Trip ON OFF 14 B (S-) A (S+) RS485 4 5 21 22 MS - SCE 1752 - R1 14 Motor Protection Relay • Intelligent motor protection & control relay - MCOMP • Economical motor protection relay - MPR 300 MPR 300 MCOMP Relay Model MCOMP MPR 300 Description Motor protection 49, 14, 46, 50N, 3, 59, 27, 47, 81H, 81L, 66, 27LV, 47a, 47b Numeric Thermal over load Locked rotor Current unbalance Phase loss Under current Over voltage Under voltage Over frequency Under frequency Max. no. of starts Reacceleration Phase reversal Intelligent relay with separate protection, display and CT modules Suitable for 50/ 60 Hz Can be used with DOL, RDOL and Star delta starters Communication options Modbus RTU, Modbus TCP IP and Profbus Not applicable Not applicable 10 to 600C < 2kg < 8 VA 4 C/O Split protection unit 92 x 123 x 103.95 80 - 240 V AC/DC Motor protection 49, 51LR, 64, 46, 37 Device code Design Functions available Other features Burden on PT Burden on CT Operating temp Weight Burden on auxiliary supply Output contacts Dim W x H x D in mm Auxiliary supply 15 Numeric Thermal overload Locked rotor Earth fault Single phasing No load running upto 88 A Trip time characteristics as per IEC947 Not applicable Not applicable 0-600C < 0.5kg < 8 VA 1NO+1NC Not applicable 240 V AC Wiring Diagrams MCOMP Relay Typical Dol feeder with M COMP 415V, 3PH, 4-wire, 50Hz R Y B N PH 240V AC Test Bus N F11 111 6A 112 F12 121 6A 122 F13 131 6A 132 N11 - 201 6 Drive Available K4 S2 P1 T3 P2 S1 Y B S2 R XC1-5 XC1-6 XC1-7 XC1-8 XC1-9 XC1-10 M COMP CT UNIT S1 X-42 S2 X-43 S S T4 CBCT Y B D1 81 82 83 84 85 86 87 88 89 90 91 92 C8 C2 PMR/ COMM Digital Output Relay C3 L&T Make MCOMP C7 AUX. VOLT C6 DIGITAL INPUTS N PH 61 62 63 64 65 66 67 71 72 Motor Status PMR/ CO LED DISPLAY ESE Alarm Pickup P 75 ESC ELECT TRIP C4 N 76 E 77 RS485 M COMP PH K3 106 82 Hand Start P.B. Hand RST P.B. Unused DI M S1 81 83 K3 106 85 84 86 87 43 K3 106 88 89 Trip S1 1 2 3 8 N BY R C1 Ref. Voltage Stop Command Start Command Start Command R T5 XC1-2 XC1-3 XC1-4 S2 P1 T2 P2 K3 XC1-1 K4 44 11 Stop P.B 12 A1 K4 21 H2 R A2 22 11 Trip Led 5 Unused Do Run Led 3 S1 CBCT 1 P1 T1 P2 Trip Run Drive Available 4 2 L11 - 201 Run Q1 NLK X-25 T X-26 T H1 G 12 N MPR300 Relay R Y B N Aux. N/O Start N/O Stop (N/C) 1 2 NC 3 4 5 6 NO MPR300 M 7 8 Aux Supply Typical connection diagram for ‘Direct Starting’ application 16 Generator Protection Relays • Multifunction generator protection relays • Percentage based generator differential relay Salient Features • Display of various parameters, trip count & trip data on 8 digit alphanumeric display • Separate LEDs for various fault indication • Four user programmable output relays • Built in self supervision & self testing feature help maintenance • Easy operation by 5 push buttons • RS485 Port for serial communication with “MSCOM” user friendly software Model Description MG30 MG30-I Generator protection Generator protection 21, 24, 27/59, 32, 37, 40, 46, 49, 50/27, 21, 24, 27/59, 32, 37, 40, 46, 49, 50/27, Device code 50V/51V, 51BF, 60FL, 64S, 68, 81 50V/51V, 51BF, 60FL, 64S, 68, 81 Design Numeric Numeric Two levels of voltage controlled O/C, Two levels of voltage controlled O/C, Thermal image with pre-alarm, Thermal image with pre-alarm, Two levels of current unbalance Two levels of current unbalance Two levels of under / over voltage Two levels of under / over voltage Two levels of under / over frequency Two levels of under / over frequency Functions available 95% + 100% stator earth fault 95% stator earth fault Two levels of over excitation Two levels of over excitation Two levels of under impedance, Two levels of under impedance, Loss of field, under power Loss of field, under power PT Fuse failure, breaker failure, PT Fuse failure, breaker failure, Inadvertent C/B closure etc. Inadvertent C/B closure etc. 1 A or 5 A site selectable 1 A or 5 A site selectable Display of parameters Display of parameters Other features Built in self supervision Built in self supervision RS485 port, MODBUS protocol RS485 port, MODBUS protocol Blocking inputs & Blocking outputs Blocking inputs & Blocking outputs Burden on CT 0.25 VA for 5 Amp CT 0.25 VA for 5 Amp CT 0.01 VA for 1 Amp CT 0.01 VA for 1 Amp CT Burden on PT 0.05 VA (MG30) 0.05 VA (MG30) Burden on auxiliary supply 8.5 VA 8.5 VA Operating temp 100C to 600C 100C to 600C Weight < 2kg < 2kg 3 C/O + (1 N/O + N/C) + separate relay 3 C/O + (1 N/O + N/C) + separate relay Output contacts 1 C/O for self supervision 1 C/O for self supervision Construction Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 Panel cutout 113 x 142 113 x 142 Ordering Information Type 1 20-110 V AC / DC or 20-110 V AC / DC or Auxiliary supply Type 2 88-264 V AC / DC 88-264 V AC / DC 17 MD32-G Generator differential 87, 50/51, 64S/87N, 68 Numeric Generator differential Bias % with dual adjustable slope Over current Stator E/F CB failure protection 1 A or 5 A site selectable Display of parameters Wave form capture feature Built in self supervision, - RS485 port 0.2 VA for 5 A, 0.01 VA for 1 A Not applicable 8.5 VA -100C to 600C < 2kg 4 C/O, S/R or H/R or time del 1 C/O for self supervision Drawout 121 x 158 x 224 113 x 142 20-110 V AC / DC or 88-264 V AC / DC Wiring Diagrams MG30 25 Display 21 10 R1 1/5A MG30 1/5A 27 11 22 7 9 R2 Funzioni Function 1/5A 28 39 29 G N.O. N.C. Microp. 26 R3 8 18 20 R4 19 4 6 R5 5 15 17 1>,Z<,Uo> 1/5A 30 41 12>,T> R1 Zc<, O> R2 U,f 1/5A W<, Ir> 31 42 32 43 2 1 33 MG30 Progr. Int. Fault 1/5A 44 37(b) R5 To Rex Relay 38(a) Expansion 23 24 C S– S+ Keyb0ard Tastiera 12 13 CE MS-SCE 1629-R0 In=5A In=1A N.O. N.C. 14 3 14 3 2 R4 B.I./B.F. (10 – 11) 16 R3 IC, 60FL 1/5A (21 – 22) 9 PIN MALE Un=100V MG30-I 25 Display 26 MG30-I 27 11 22 7 9 8 18 20 19 4 6 5 15 17 18 R2 Funzioni Function R3 28 39 29 G 21 10 R1 Microp. I>, Z<, Io> 1/5A 30 41 I2>, T> R1 Zc<, R2 > R5 U, 1 1/5A w<+ Ir> 31 42 32 43 R4 IC, 60FL B.I / B.F. 1/5A R3 3 2 Progr. 1/5A 33 Int.fault 37(b) R5 c ss+ Keyboard Tastiera 12 In = 1A In = 5A 13 N.O. N.C. 14 3 2 1 14 R4 (21 - 22) N.O. N.C. (10 - 11) 38(0) 23 24 To Rex Relay Expansion RS485 MS-SCE1759-R0 MD32-G A B 87G + 87N C I1A 25 26 I1C 21 10 R1 Display 1/5A I1B 11 22 7 9 Microp. R2 1/5A MD32-G 27 1/5A 28 39 Function R3 8 18 20 R4 19 4 6 R5 5 15 17 G F187G F287G F87N 29 R4 30 41 I2B R = Stabilising resistor Z = Protection surge arrester (if required) I2C B3 Z 1/5A 33 L/+ 12 N/- 13 Progr. Int. Fault 1/5A ˜˜˜ 50-60 _ ˜ ˜ ˜= Keyboard R5 N.O. N.C. (10) N.O. N.C. 16 14 1/5A 31 42 32 43 R R2 R3 1/5A I2A R1 (21) 3 B2 B1 C SS+ 2 1 34/38 23 24 9 Pin Male 18 Transformer Protection Relay • Percentage based transformer differential relay • 3 Phase thermal + over current + earth fault relay for transformer protection Salient Features • Display of various parameters, trip count & trip data on 8 digit alphanumeric display • Separate LEDs for individual fault indication • Four user programmable output relays • Built in self supervision & self testing feature help maintenance • Easy operation by 5 push buttons • RS485 Port for serial communication with “MSCOM” user friendly software Model Description Device code Design Functions available Other features Burden on CT Operating temp Weight Burden on auxiliary supply Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply 19 Type 1 Type 2 MD32T MD32TM IM30T Transformer differential + Restricted E/F 87 RYB, 87N Transformer differential 3 Ph O/C, E/F + Thermal 50/51 RYBN, 49, 46, I2t, 51BF, 50N/51N Numeric Numeric Lowset differential Lowset O/C Lowset op time : <=30mS Highset O/C Highset differential Lowset E/F Highset op time : 6-20mS Highset E/F Dual slope bias Thermal overload Highset can be Biased / Unbiased Lowset current unbalance with 2nd harmonic restraint setting Definite / Inverse time tripping 5th harmonic restraint setting Highset current unbalance Auto correction of CT ratio Inrush energy protection Zero sequence compensation CB failure function Blocking function Blocking function 87 RYB Numeric Lowset differential Lowset op time : <=30mS Highset differential Highset op time : 6-20mS Restricted earth fault Dual slope bias Highset can be Biased / Unbiased 2nd harmonic restraint setting 5th harmonic restraint setting Auto correction of CT ratio Zero sequence compensation Blocking function Display of parameters Display of parameters Built in self supervision Built in self supervision RS485 port RS485 port 1 A or 5 A site selectable 1 A or 5 A site selectable Waveform capture feature Waveform capture feature 0.2 VA for 5 A, 0.01 VA for 1 A 0.2 VA for 5 A, 0.01 VA for 1 A 100C to 600C 100C to 600C < 2kg < 2kg 8.5 VA 8.5 VA 5 C/O, S/R or H/R or Time del 5 C/O, S/R or H/R or Time del Draw out Draw out 121 x 158 x 224 121 x 158 x 224 113 x 142 113 x 142 Ordering Information 20-110 V AC / DC 20-110 V AC / DC 88-264 V AC / DC 88-264 V AC / DC Display of parameters Built in self supervision RS485 port 1 A or 5 A site selectable 0.2 VA for 5 A, 0.01 VA for 1 A 100C to 600C < 2kg 8.5 VA 5 C/O, S/R or H/R or Time del Draw out 121 x 158 x 224 113 x 142 20-110 V AC / DC 88-264 V AC / DC Wiring Diagrams MD32T / MD32TM A B C I1A 87T + 87N 25 In1 26 I1C MD32T 27 28 39 V1 V2 V1 á V2 1/5A Kv = R3 F187T F287T F87N 29 R1 R2 R3 1/5A I2A R = Stabilising resistor Z = Protection surge arrester (if required) R4 30 41 I2B I2C 19 N.C. 4 6 R5 5 15 17 16 14 3 B3 Progr. R5 Int. Fault 1/5A Z ˜˜˜ 1/5A 33 50-60 L/+ 12 IEC 255 R4 1/5A 31 42 32 43 R R2 Function V1 V2 ˜ N/- 13 ˜ ˜ N.O. 11 22 7 N.C. 9 (10) 8 18 N.O. 20 Microp. 1/5A (21) 21 10 R1 Display 1/5A I1B B2 2 1 34/38 23 24 B1 C SS+ Keyboard 9 Pin Male = IM30T A B C A 25 B C A B C 25 25 26 26 26 27 27 27 28 39 29 28 39 29 28 39 29 41 30 32 43 31 41 30 32 43 31 41 30 32 43 31 R2 IM30T 1/5A 42 42 42 33 33 33 1/5A Progr. Int.fault 44 R1 R4 R2 5 15 17 R5 R3 R4 R5 16 RT 14 BIO 3 2 1 BIF In = 1A L/+ 12 IEC 255 ˜ ˜ ˜ BT 2 50 F46 F49 F50 F51 F50N F51N F51BF I2t = K 8 N.O. 18 20 N.C. 19 4 6 R3 Function PRESA/TAP 31 Ion = 5A PRESA/TAP 33 Ion = 1A N/- 13 _ ˜ ˜ ˜= Keyboard (21) N.O. 11 22 N.C. 7 9 (10) Microp. 1/5A In = 5A 21 10 R1 Display 1/5A C SS+ 34/38 23 24 9 Pin Male 20 Feeder Protection Relays • 3 Phase O/C & E/F relay with Highset + Auto Reclosure (Optional) • 3 Phase directional O/C & E/F relay with highset Salient Features • Display of various parameters, trip count & trip data on LCD screen • Separate LEDs for various fault indication • Built in self supervision & self testing feature • Wave form capturing • RS485 Port for serial communication with “MSCOM” user friendly software • Front RS232 Port for local programming Model MC20 MC30 Description Device code Design 3P O/C + E/F + Highset + Autoreclosing (optional) 51, 51N, 50, 50N, 51BF, 79 (optional) Numeric Lowset O/C 2 Highset O/C levels Lowset E/F 2 Highset E/F levels Time current curves selectable according to IEC/IEEE standards Auto reclose (In MC20-R) Breaker failure protection Circuit breaker control via serial port Blocking output and blocking input for pilot wire selectivity co-ordination Time tagged multiple event recording Oscillographic wave form capture Accepts 3 digital inputs Display LCD 16 (2 x 8) characters 3rd Harmonic filter on the neutral input current Password protection facility 1 A or 5 A site selectable Display of parameters Built in supervision Modbus RTU / IEC870-5-103 Communication protocols Front RS232 port for local programming Oscillographic recording of input quantities RS485 serial communication port on back panel 0.1 VA for 1 A, 0.3 VA for 5 A NA < 7 VA -100C to 550C < 1.5kg 4 C/O contacts Drawout 83 x 164 x 225 64 x 137 Ordering Information 24-110 V AC/DC 88-264 V AC/DC 3P O/C + E/F + Highset 51, 51N, 50, 50N, 49, 51BF Numeric Lowset O/C 2 Highset O/C levels Lowset E/F 2 Highset E/F levels Thermal image Breaker failure protection Circuit breaker control via serial port Blocking output and blocking input for pilot Wire selectivity co-ordination Time tagged multiple event recording Oscillographic wave form capture Accepts 3 digital inputs Display LCD 16 (2 x 8) characters Time current curves selectable according to IEC/IEEE standards Password protection facility Functions available Rating Other features Burden on CT Burden on PT Burden on aux. supply Operating temp Weight Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply 21 Type 1 Type 2 1 A or 5 A site selectable Display of parameters Built in supervision Modbus RTU / IEC870-5-103 Communication protocols Front RS232 port for local programming Oscillographic recording of input quantities RS485 serial communication port on back panel 0.1 VA for 1 A, 0.3 VA for 5 A NA < 7 VA -100C to 550C < 1.5kg 4 C/O Contacts Drawout 83 x 164 x 225 64 x 137 24-110 V AC/DC 88-264 V AC/DC Wiring Diagrams MC20 A B C A B C Display 6 6 R1 16 7 7 R2 MC20 R1 F51 14 R4 1/5A 9 BT 2 Progr. Int.fault 50 Output Relays R2 18 17 R3 14 Rele DI Uscita R3 R4 D3 20 D2 21 D1 19 22 Digital Inputs D3 20 D2 21 D1 19 22 Ingressi Digitali H L In = □ 1A □ 5A lon = □ 1A □ 5A Auxiliary Supply Alimentazione Ausiliaria C A (S+) B (S+) 10 RS232 11 Output Relays Rele DI Uscita 15 12 F51N 9 16 13 R2 F50N 8 8 R3 15 F50 1/5A 5 5 18 17 Funzioni Functions 4 4 R1 Microp. 1/5A 3 2 1 C Keyboard Tastiera Ingressi Digitali 13 12 To I/0 Relay Expansion All’ Espansione DI I/0 3 Comune Comune 2 1 RS485 RS485 A (S+) B (S-) Digital Inputs BPMC MS - SCE 1828 - R1 MS - SCE 1828 - R1 Standard Output MS - SCE 1839 - R2 I/O Output MC30 Display 4 5 1/5A MC30 6 7 1/5A 8 9 1/5A Funzion Functions F50 F51 F50N F51N 1A 16 R1 16 R2 18 R2 18 Relays 17 Rele 14 DI Uscita 17 Output Relays 14 Rele 15 DI Uscita 13 R3 R1 R4 R2 R3 12 20 21 19 22 D3 D2 1/5A In= R1 Microp. R4 D1 Progr. Int.fault 5A Auxiliary Supply 11 RS232 Keyboard Tastiera BPMC R3 15 20 21 19 22 D3 D2 D1 Incressi Digital A (S+) B (S-) 3 2 1 MS-SCE1895-R2 Standard Output 13 Expansion 12 All Espansione C RS485 Digital Input Ingress Digital To I/0 Relay L H C 10 Digital Inputs Output A (S+) B (S-) 3 2 1 DI I/0 Comune Comune RS485 MS -SCE1924-R2 I/O Output 22 Feeder Protection Relays / Vector Shift Relay • 3 Phase directional O/C & E/F relay with Highset • 3 Phase voltage and frequency relay with vector shift FMR - Salient Features :• Display of various parameters, trip count & trip data on LCD screen • Separate LEDs for various fault indication • Built in self supervision & self testing feature • Wave form capturing • RS485 Port for serial communication with “MSCOM” user friendly software • Front RS232 Port for local programming Model FMR UM30A Description Device code Design Feeder manager relay 2 46, 49, 50/51, 67, 50N/51N, 67N, 27/59, 59UO, 74, 81, 86, 121, I t Numeric Three levels for phase over current independently programmable as directional or non directional Three levels for earth fault independently programmable as directional or non directional Thermal image Selectable time current curves according to IEC and IEEE standards Two over/under voltage levels Two over/under frequency levels Zero sequence over voltage level Two negative sequence current levels One positive sequence over voltage level One negative sequence undervoltage level Trip circuit supervision Associated circuit breaker control Breaker failure protection Breaker interruption energy 1 A or 5 A site selectable / 100-125 V PTI Graphical display 128 x 64 dots Display of V, I, PF, kW, kVA, kVAr and thermal status Modbus RTU / IEC870-5 communication protocols RS232 serial communication port on front face MIMIC diagram on LCD Oscillographic recording of input quantities RS485 serial communication port on back panel Phase 0.01 VA at In = 1 A; 0.2 VA at In = 5 A neutral 0.01 VA at In = 1 A; 0.2 VA at In = 5 A 0.1 VA at UN -100C to 550C < 2kg < 10 VA 6 C/O contacts Drawout 121 x 164 x 224 113 x 142 Ordering Information 20-110 V AC/DC or 88-264 V AC/DC 3 Phase V and F relay with vector shift 24, 27d/59d, 47, 59, 59Uo, 78, 81 Numeric Over fluxing Two levels of under / over voltage Two levels of under / over frequency Zero seq. voltage Voltage unbalance Vector shift detection Functions available Rating Other features Burden on CT Burden on PT Burden on aux. supply Operating temp Weight Burden on aux. Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply 23 Type 1 Type 2 Display of parameters Built in self supervision RS485 Port NA 0.2 VA / phase at UN 8.5 VA 100C to 600C < 2kg 3 C/O + (1 N/O + 1 N/C) + separate relay 1 C/O for self supervision Drawout 121 x 158 x 224 113 x 142 20-110 V AC / DC or 88-264 V AC / DC Wiring Diagrams FMR A B C 2 A B C 2 25 28 R1 3 4 3 4 5 6 5 6 7 8 7 8 9 9 41 41 42 43 42 43 44 45 44 45 46 46 47 47 48 ULTRA 15 14 Feeder Manager Relay N.O N.C R3 25 R4 33 R1 POWER R5 32 R2 TRIP 15 22 31 R3 R6 R4 ON 12 25 15 Digital Inputs 25 19 Ingressi 38 Digitali 27 17 R5 D1 OFF R6 48 D2 D3 D4 + - Auxiliary Supply Alimentazione Ausiliaria (25) 34 In = □ 1A □ 5A lon = □ 1A □ 5A Un = 230Vac Max. 24 35 R2 Trip Oxi. sup. 11 16 21 H L Front-RS252 MS - SCE 1844-R3 BPU 34 37 ON UM30A 25 A R1 Display 26 Microp. B C 27 UM30A 28 39 29 Function 41 30 EA Uo UC EC UA UB ˜ ˜˜ BT 2 50 44 N/- 13 _ ˜ ˜ ˜= R3 F27 / 59 F27d / 59d R1 F59s F59U F81 F59 / 81 R3 Progr. Int. Fault EB L/+ 12 R2 Keyboard R2 R4 R5 R4 R5 14 BI< BI> C SS+ 9 Pin Male (21) 21 10 N.O. 11 22 N.C. 7 9 (10) 8 18 N.O. 20 19 N.C. 4 6 5 15 17 16 14 3 2 1 34/38 23 24 IEC 255 24 (-20%) - 110 (+20%) Vac 24 (-20%) - 125 (+20%) Vdc 80 (-20%) - 220 (+20%) Vac 90 (-20%) - 250 (+20%) Vdc 24 Control & Supervision Relays • Power management relay • Multifunction 3 phase measuring instrument Salient Features • Display of various parameters, event count & event data on 8 digit alphanumeric display • Separate LEDs for various fault indication • Four user programmable output relays • Built in self supervision & self testing feature help maintenance • Easy operation by 5 push buttons • RS485 Port for serial communication with “MSCOM” user friendly software Model MW33 Description Device code Design Power management 81, 27, 59, 32P, 32Q Numeric Frequence 2 stages, Voltage 2 stage, Power factor 2 stage, Active power 2 stage, Capacitor reactive power 2 stage. Actual measurement of freq, V, I, PF, active power, reactive power Functions available Other features Burden on CT Burden on PT Operating temp Weight Burden on auxiliary supply Output contacts Construction Dim W x H x D in mm Panel cutout Auxiliary supply 25 Type 1 Type 2 SPM21 Auto synchronising relay 25, 27 Numeric Auto synchronising with Adjustable voltage, Adjustable frequency, Adjustable phase angle Adjustable reclose time, Bus Live / Dead operation, Speed regular control, Voltage regulator control, Digital inputs to monitor CB position 110V - 125 V PT input Display of parameters Display of parameters, MD recording & data logging Built in self supervision, RS485 port, event recording RS485 port NA O.2 VA for 5 A, 0.01 VA for 1 A 0.04 VA 0.04 VA 100C to 600C 100C to 600C < 2kg < 2kg 8.5 VA 8.5 VA max 5 C/O 5 C/O Drawout Drawout 121 x 158 x 224 121 x 158 x 224 113 x 142 113 x 142 Ordering Information 20-110 V AC / DC or 20-110 V AC / DC 88-264 V AC / DC 88-264 V AC / DC RRS Generator load sharing 95 Static Active / reactive power Over power Load sharing Frequency control 110 V PT input 1 A / 5 A CT input NA < 5 VA 100C to 600C < 1.5kg 8.5 VA 3 N/O Drawout 71 x 158 x 224 62 x 142 20-110 V AC / DC or 88-264 V AC / DC Upto 380 V AC 1 A / 5 A Wiring Diagrams MW33 25 26 Microp. 27 1/5A 28 39 29 1/5A 41 MW33 R2 Funzioni Finction R3 F32 W 30 Un Un In = 1A 32 43 Wh VARh 31 42 33 R4 R3 R4 R5 14 3 2 Progr. R5 Int.fault _ L/+12 L/- 13 Un = 100V R1 R2 F32 VAR 44 In = 5A 21 (21) 10 11 N.O. 22 7 N.C. 9 8 (10) 18 20 N.O. 19 4 N.C. 6 5 15 17 16 14 3 2 1 34/38 23 24 R1 Display 1/5A ˜ ˜˜ C SS+ Keyboard Tastiera = 9 Pin Male IEC 255 SPM21 Display R1 21 10 R2 11 22 7 9 F R3 8 18 20 F R4 19 4 6 U R5 5 15 17 U 25 Microp. UG 26 SPM21 Function 29 UB F25SX Progr. Int. Fault 30 41 G1 UG SPM21 52 R1 F+ R2 F- R3 U+ R4 U- R5 16 44 UB L/+ 12 C SS+ Keybord B.I. BR 52 (N.O.) 14 3 2 1 BX BR SX 34/38 23 24 9 PIN MALE N/- 13 IEC 255 52 C RRS G Media Average 15 14 To other RRS Relays - 12 R1 3 + + Increase 13 4 1 T Settings VOIOCOS 7 Operation + 1 R2 6 2 OPTO 8 9 + OPTO + - Decrease 17 R3 Over Power 18 Lood Shedding 22 2 (.) (.) Freq. control 21 11 10 3 1 2 Lood Shedding 3 Freq. control Open Open Open Open Open Open Open Open Yes Yes Yes Yes Open Close Yes No 26 Voltage and Frequency Relays • 3 Phase voltage and frequency relay with df/dt & dv/dt • 1 Phase voltage and frequency relay Salient Features • Display of various parameters, trip count & trip data on LCD screen • Separate LEDs for individual fault indication • Built in self supervision & self testing feature • RS485 port for serial communication with “MSCOM” software • Easy operation by push buttons Model Description Device code Design Functions available Rating Other features UFD34 MC1V MC3V 3 Ph voltage and Frequency relay 81, 27, 59, df/dt, dv/dt Numeric Selectable 4 stages of frequency as under/ over frequency Selectable 2 stages of voltage as under/over voltage Selectable 2 stages of df/dt Selectable 1 stages of de/dt Blocking output and Blocking Input Time tagged multiple event recording 100-125 V Display of parameters Built in self supervision Oscillogarphic recording of input quantities RS485 serial communication port on back panel Single phase voltage and Frequency relay 27, 59, 81 Numeric Two under voltage elements Two over voltage elements One under frequency element One over frequency element Blocking output and Blocking input Time tagged multiple event recording Oscillogarphic wave form capture Display LCD 16 (2 x 8) characters 3 Ph voltage and Frequency relay 27, 59, 47, 59 V 0, 81 Numeric Two under voltage elements Two over voltage elements One under frequency element One over frequency element One zero sequence over voltage element One negative sequence under voltage element One positive sequence over voltage element Oscillographic wave form capture Modbus RTU / IEC870-5-103 Communication Protocols Display LCD 16 (2 x 8) characters 100-125 V Display of parameters Built inSelf supervision Modbus RTU / IEC870-5-103 Communication protocols Front RS232 port for local Programming Oscillogarphic recording of input quantities RS485 serial comunication port on Back panel 0.1 VA for 1 A, 0.3 VA for 5 A NA -100C to 550C < 1.5kg < 7 VA 4 C/O Contacts + 1 C/O for self supervision Drawout 83 x 164 x 224 64 x 137 Ordering Information 20-110 V AC/DC or 88-264 V AC/DC 100-125 V Display of parameters Built in self supervision Modbus RTU / IEC870-5-103 Communication protocols Front RS232 port for local Programming Oscillogarphic recording of input quantities RS485 serial communication port on Back panel 0.1 VA for 1 A, 0.3 VA for 5 A NA -100C to 550C < 1.5kg < 7 VA 4 C/O Contacts + 1 C/O for self supervision Drawout 83 x 164 x 224 64 x 137 Burden on CT Burden on PT Operating temp Weight Burden on auxiliary Not applicable 0.04 VA 0 0 -10 C to 60 C < 2.5kg 8.5 VA 4 C/O contacts + 1 C/O for Output Contacts self supervision Construction Drawout Dim W x H x D in mm 121 x 164 x 224 Panel cutout 113 x 142 Auxiliary supply 27 20-110 V AC/DC or 88-264 V AC/DC 20-110 V AC/DC or 88-264 V AC/DC Wiring Diagrams UFD34 25 A 26 28 39 29 C Function F81 - 1 41 30 R2 F81 - 3 F81 - 4 R3 Fdf / dt F27 / 59 R4 Progr. Int. Fault IEC 255 N/- 13 _ ˜ ˜ ˜ R3 8 18 20 R4 19 4 6 R5 5 15 17 R1 F81 - 2 L/+ 12 R2 UFD34 R5 N.O. 11 22 7 9 Microp. 27 B (21) 21 10 R1 Display C SS+ = N.O. N.C. 16 14 3 2 1 34/38 23 24 14 BI< BI> Keyboard N.C. (10) 9 Pin Male MC1V Display R1 R1 16 16 Microp. 5 1F27 2F27 1F59 R3 R4 Progr. 20 Digital 21 Inputs D3 D2 R4 R3 14 Rele’ DI Uscita 12 2F59 Int.fault 17 D3 20 D2 21 D1 19 11 C C A (S+) B (S-) RS232 3 2 1 Ingressi Digitali 13 12 To I/0 Relay Expansion All Espansione DI I/0 3 Comune Comune 2 1 RS485 RS485 A (S+) B (S-) Keyboard Tastiera MS - SCE 1836 - R2 Digital Inputs 22 19 Ingressi Digitali 22 D1 10 Rele’ DI Uscita 15 H L Auxiliary Supply Alimentazione Ausiliaria Output Relays 13 R2 R3 Output Relays 14 15 R1 18 18 17 Funzioni Functions 4 R2 R2 MC1V BPMC MS - SCE 1836 - R2 Standard Output MS - SCE 1837 - R2 I/O Output MC3V Display 4 A R1 16 R1 16 R2 18 Output Relays R3 17 14 Rele’ Di Uscita Microp. 5 MC3V 6 B Funzioni Functions 7 F27 F47 9 F27d F59d 15 R1 R4 R4 Int.fault UB Rele’ DI Uscita 12 R2 R3 Output Relays 15 13 D3 20 D2 21 Digital Inputs D1 19 22 Ingressi Digitali UA Progr. EC 17 14 F59 EA UC 18 R3 F24 8 C R2 D3 20 D2 21 D1 19 22 Ingressi Digitali 13 12 To I/0 Relay Expansion All Espansione DI I/0 C 3 Comune Comune A (S+) 2 1 RS485 L H R5 EB Auxiliary Supply Alimentazione Ausiliaria 10 RS232 11 C A (S+) B (S-) 3 2 1 RS485 Keyboard Tastiera MS - SCE 1834 - R1 B (S-) Digital Inputs BPMC MS - SCE 1834 - R1 Standard Output MS - SCE 1835 - R1 I/O Output 28 MD32TM 29 MD32G MG30/ MG30I scheme - 2 scheme - 1 MPR300 MC61A/MC61C MC12/ME12 SC14S G2 UFD34, UM30 G1 MRP11 MV12 SPM21 SCM21 MV12/MC3V MC31A/MC61A MC61C/FMR MC61A/ MC61C MV12/MC3V scheme - 1 Motor scheme - 2 Motor MM30/ MCOMP etaCON L / RPM8 / RPM14 APFC Panel Schematic - Relay Application 1.12 , over & Vadodara cover: Low Voltage & Medium Voltage Switchgear Switchboard Electrical Design AC Drives & Building Management Solutions Protective Relays, Earthing & Harmonics Energy Conservation & Management New Vadodara Larsen & Toubro Limited Switchgear Training Centre Behind L&T Knowledge City, Near Village Ankhol, Vadodara - 390 019. Tel: +91 265 245 7805 E-mail : STC-VADODARA@LNTEBG.COM Electrical Standard Products (ESP) Branch Offices: REGISTERED OFFICE AND HEAD OFFICE L&T House, Ballard Estate P. O. Box 278 Mumbai 400 001 Tel: 022-67525656 Fax: 022-67525858 Website: www.Larsentoubro.com ELECTRICAL STANDARD PRODUCTS (ESP) 501, Sakar Complex I Opp. Gandhigram Rly. Station Ashram Road Ahmedabad 380 009 Tel: 079-66304006-11 Fax: 079-66304025 e-mail: esp-ahm@LNTEBG.com 38, Cubbon Road, P. O. Box 5098 Bangalore 560 001 Tel: 080-25020100 / 25020324 Fax: 080-25580525 e-mail: esp-blr@LNTEBG.com 131/1, Zone II Maharana Pratap Nagar Bhopal 462 011 Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Fax: 0755-3080502 e-mail: esp-bho@LNTEBG.com Plot No. 559, Annapurna Complex Lewis Road Bhubaneswar 751 014 Tel: 0674-6451342, 2436690, 2436696 Fax: 0674-2537309 e-mail: nayakd@LNTEBG.com SCO 32, Sector 26-D Madhya Marg, P. O. Box 14 Chandigarh 160 019 Tel: 0172-4646840, 4646853 Fax: 0172-4646802 e-mail: esp-chd@LNTEBG.com L&T Construction Campus TC-1 Building, II Floor Mount-Poonamallee Road Manapakkam Chennai 600 089 Tel: 044-2270 6800 Fax: 044-22706940 e-mail: esp-maa1@LNTEBG.com 67, Appuswamy Road Post Bag 7156 Opp. Nirmala College Coimbatore 641 045 Tel: 0422-2588120 / 1 / 5 Fax: 0422-2588148 e-mail: esp-cbe@LNTEBG.com Khairasol, Degaul Avenue Durgapur 713 212 Tel: 2559848, 2559849, 2559844 Fax: 0343-2553614 e-mail: esp-dgp@LNTEBG.com 5, Milanpur Road, Bamuni Maidan Guwahati 781 021 Tel: +91 8876554410 / 8876554417 Fax: 361-2551308 e-mail: hazrasudipto@LNTEBG.com II Floor, Vasantha Chambers 5-10-173, Fateh Maidan Road Hyderabad 500 004 Tel: 040-67015052 Fax: 040-23296468 e-mail: esp-hyd@LNTEBG.com Monarch Building, 1st Floor D-236 & 237, Amrapali Marg Vaishali Nagar Jaipur 302 021 Tel: 0141-4385914 to 18 Fax: 0141-4385925 e-mail: esp-jai@LNTEBG.com Akashdeep Plaza, 2nd Floor P. O. Golmuri Jamshedpur 831 003 Jharkhand Tel: 0657-2312205 / 38 Fax: 0657-2341250 e-mail: esp-jam@LNTEBG.com Skybright Bldg; M. G. Road Ravipuram Junction, Ernakulam Kochi 682 016 Tel: 0484-4409420 / 4 / 5 / 7 Fax: 0484-4409426 e-mail: esp-cok@LNTEBG.com 3-B, Shakespeare Sarani Kolkata 700 071 Tel: 033-44002572 / 3 / 4 Fax: 033-22821025 / 7587 e-mail: esp-ccu@LNTEBG.com A28, Indira Nagar, Faizabad Road Lucknow 226 016 Tel: 0522-4929905 / 04 Fax: 0522-2311671 e-mail: esp-Lko@LNTEBG.com No: 73, Karpaga Nagar, 8th Street K. Pudur Madurai 625 007 Tel: 0452-2537404, 2521068 Fax: 0452-2537552 e-mail: esp-mdu@LNTEBG.com EBG North Wing Office-Level 2 Gate 7, Powai Campus Mumbai 400 072 Tel: 022-67052874 / 2737 / 1156 Fax: 022-67051112 e-mail: esp-bom@LNTEBG.com 12, Shivaji Nagar North Ambajhari Road Nagpur 440 010 Tel: 0712-2260012 / 6606421 Fax: 2260030 / 6606434 e-mail: esp-nag@LNTEBG.com 32, Shivaji Marg P. O. Box 6223 New Delhi 110 015 Tel: 011-41419514 / 5 / 6 Fax: 011-41419600 e-mail: esp-del@LNTEBG.com L&T House P. O. Box 119 191/1, Dhole Patil Road Pune 411 001 Tel: 020-66033395 / 66033279 Fax: 020-26164048 / 26164910 e-mail: esp-pnq@LNTEBG.com Crystal Tower, 4th Floor, G. E. Road Telibandha Raipur - 492 006 Tel: 0771-4283214 e-mail: esp-raipur@LNTEBG.com 3rd Floor Vishwakarma Chambers Majura Gate, Ring Road Surat 395 002 Tel: 0261-2473726 Fax: 0261-2477078 e-mail: esp-sur@LNTEBG.com Radhadaya Complex Old Padra Road Near Charotar Society Vadodara 390 007 Tel: 0265-6613610 / 1 / 2 Fax: 0265-2336184 e-mail: esp-bar@LNTEBG.com 48-8-16, Dwarakanagar Visakhapatnam 530 016 Tel: 0891-6701125 to 30 Fax: 0891-6701139 e-mail: esp-viz@LNTEBG.com Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here. Larsen & Toubro Limited Electrical Standard Products Powai Campus, Mumbai 400 072 Customer Interaction Center (CIC) BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858 Tel : 022 6774 5858, Fax : 022 6774 5859 E-mail : cic@LNTEBG.com Website : www.LNTEBG.com Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai 400 001, INDIA SP 50297-R1