PROTECTION RELAYS Over Current Relays Page Types - MC31A, MC61A, MC61C 5 Current Sensing Relays Page Types - MC11A, ME11, SCKIS Technical Data 5/2 Technical Data 5/5 Wiring Diagram 5/3 Wiring Diagram 5/6 Ordering Information 5/4 Ordering Information 5/7 Neutral Displacement, Generator Load Sharing, U/V or Over Voltage Page Types - MND11, RRS, MV11 Secondary Relays Page Types - TCS01, MTM01, PTF03 Technical Data 5/8 Technical Data 5/11 Wiring Diagram 5/9 Wiring Diagram 5/12 Ordering Information 5/13 Ordering Information Power Factor Control or Monitoring Relays 5/10 Page Types - PFC8, PFC14, MVP01 Motor Protection Relay Page Type MM30 Technical Data 5/14 Technical Data 5/17 Wiring Diagram 5/15 Wiring Diagram 5/18 Ordering Information 5/16 Ordering Information 5/19 PROTECTION RELAYS Generator Protection Relays Page Types - IM3GV, IM30G, MD32G Synchronising Relay Page Types - SPM21, SCM21 Technical Data 5/20 Technical Data 5/23 Wiring Diagram 5/21 Wiring Diagram 5/24 Ordering Information 5/22 Ordering Information 5/25 Voltage / Frequency Relay, Direction O/C, E/F Relay Page Types - UFD34, UM30A, DM30 Transformer Protection Relay Capacitor Bank Protection Relay Page Types - MD32T, IM30T, DIN30C Technical Data 5/26 Technical Data 5/29 Wiring Diagram 5/27 Wiring Diagram 5/30 Ordering Information 5/28 Ordering Information 5/31 Control and Supervision Relays Page Types - MW33, MU30 Reverse Power Relay Page Type MRP11 Technical Data 5/32 Technical Data 5/35 Wiring Diagram 5/33 Wiring Diagram 5/36 Ordering Information 5/34 Ordering Information 5/36 5 PROTECTION RELAYS Other Relays Page Types - MX7/5, MC-R, REX, CPSC, MSCOM Ordering Information 5 5/37 PRODUCT DESIGN STANDARDS Reference standards : IEC 60255, IEC 61000 Dielectric test : IS 3231 / IEC 60255-5 Impulse test : IS 8686 / IEC 60255-5 HF disturbance test : IS 8686 / IEC 60255-22-1 Electrostatic discharge test : IEC 61000-4-2 Electrical fast transient : IEC 61000-4-4 Radiated electro magnetic field test : IEC 61000-4-3 Surge immunity : IEC 61000-4-5 Ring wave test : IEC 61000-4-12 Voltage dips & interruption test : IEC 61000-4-11 Power frequency magnetic test : IEC 61000-4-8 IS3231, IS8686 5 TIME - CURRENT CHARACTERISTICS (AT TMS=1) For Trip time at TMS other than 1 Trip time = (Trip time at TMS=1) x TMS OR 50msec whichever is more A : Normal Inverse 3.0 Sec. B : Normal Inverse 1.3 Sec. C : Very Inverse D : Extreme Inverse BACK 5/1 TECHNICAL DATA THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS ✦ ✦ ✦ ✦ ✦ ✦ Display of Currents, settings, Trip data & Trip history for analysis & trouble shooting. Built in Self Supervision & Self testing feature to ensure continuous reliability. Separate Indication for power ON & Programming mode or relay fault. Separate fault indication. In MC61C - Communication with Computer & breaker control through RS 485 Port. Four User Programmable Output relays. Model MC31A MC61A MC61C Description 3 Phase O/C + E/F 3 Phase O/C + E/F + Highset 3 Phase O/C + E/F + Highset 5 Communication and breaker control Device Code 51 RYBN 50/51 RYBN 50/51 RYBN Design Numerical Relay Numerical Relay Numerical Relay Functions Available Lowset O/C -ls Lowset O/C -ls Lowset O/C -ls Lowset E/F -Os Highset O/C -lhs Highset O/C -lhs Lowset E/F -Os Lowset E/F -Os Highset E/F -Ohs Highset E/F -Ohs Settings Other Features Burden on CT O/C ls = 20-200% Step 5% O/C ls = 20-200% Step 5% O/C ls = 20-200% Step 5% E/F Os = 5-80% Step 5% E/F Os = 5-80% Step 5% E/F Os = 5-80% Step 5% HS O/C = (0.2 to 40) x In step of - HS O/C = (0.2 to 40) x In step of - HS O/C = (0.2 to 40) x In step of - 0.2 In or disable 0.2 In or disable 0.2 In or disable HS E/F = (0.1 to 20) x On step of - HS E/F = (0.1 to 20) x On step of - HS E/F = (0.1 to 20) x On step of - 0.1 On or disable 0.1 On or disable 0.1 On or disable Time Characteristics available - Time Characteristics available - Time Characteristics available - NI, VI, EI, or Definite Time NI, VI, EI, or Definite Time NI, VI, EI, or Definite Time TMS 0.1 - 1.6 Step 0.05 TMS 0.1 - 1.6 Step 0.05 TMS 0.1 - 1.6 Step 0.05 Site selectable Trip time Char. Site selectable Trip time Char. HS delay:0.1-2 Sec step 0.01 Sec. or Inst. Highset can be disabled RS 485 Communication Display of Currents, Trip count Display of Currents, Trip count Breaker control Self supervision feature Self supervision feature Auto doubling of highset, Relay co-ordination 0.25 VA on CT/Phase 0.25 VA on CT/Phase 0.25 VA on CT/Phase Burden on PT Not applicable Not applicable Not applicable Operating temp 0° to 60° C 0° to 60° C 0° to 60° C Weight < 2kg < 2kg < 2kg Burden on Auxiliary supply 10 VA 10 VA 10 VA Output Contact 1 N/O contact for self suprvn 1 N/O contact for self suprvn 1 N/O contact for self suprvn Construction Drawout Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224 Panel Cutout 113 x 142 113 x 142 113 x 142 5/2 BACK WIRING DIAGRAM THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS 5 MC31A MC61A MC61C BACK 5/3 ORDERING INFORMATION THREE PHASE OVER CURRENT AND EARTH FAULT RELAYS Model MC31A Description 3 Phase Over current and Earth Fault Relay Catalogue No. MC31A 00 Catalogue No. Selection Guide for MC31A 5 Model MC61A Description 3 Phase Over current and Earth Fault Relay Catalogue No. MC61A 00 Catalogue No. Selection Guide for MC61A Model MC61C Description 3 Phase Over current and Earth Fault Relay Catalogue No. MC61C 00 Catalogue No. Selection Guide for MC61C 5/4 BACK TECHNICAL DATA CURRENT SENSING RELAYS Single Phase Over current / Earth fault Relay Sensitive E/F Relay and Instantaneous Current Relay ✦ ✦ ✦ ✦ Easy Setting through front panel DIP Switches. Indication for Power ON and trip status. Test feature - helps maintenance. Compact, Light weight helps in reducing panel size & thickness. Model MC11A ME11A SC14S 5 Description 1 Ph O/C or E/F 1 Ph Sensitive E/F Instantaneous current relay Device Code 50/51 or 50N/51N 50N/51N 87 N / 64 R Design Microcontroller Based Microcontroller Based Static Functions Available Lowset O/C -ls Lowset S E/F -ls Highset O/C -lhs Highset S E/F -lhs Settings Lowset E/F -Os Highset E/F -ls O/C ls = 50-200% Step 10% OR S E/F = 1-16% step 1% E/F ls = 10-40% Step 2% OR HS S E/F = (2-16) xls ls = 10-40% step 5% E/F ls = 20-80% Step 4% in steps of 2 ls OR 20-80% step 10% Time Characteristics available- Time Characteristics available- HS O/C = (2-16) xls step 2 ls HS E/F = (2-16) xls step 2 ls Time Characteristics available- Other Features NI, VI, EI, or Definite Time NI, VI, EI, or Definite Time Instantaneous (25ms) OR 3 ranges of def Time (1, 10, 100) 3 ranges of def Time (1, 10, 100) time delayed 100ms / 200 ms TMS : 0.1 - 1.6 Step 0.1 TMS : 0.1 - 1.6 Step 0.1 Self Powered Site selectable Trip time Char. Site selectable Trip time Char. Relay testing Possible by ext.24V Supply Highset can be disabled Highset can be disabled Flag indication / LED indication Harmonic rejection Burden on CT 0.25 VA on CT 0.25 VA on CT 6 VA Burden on PT Not applicable Not applicable Not applicable Operating temp 0° to 55° C 0° to 55° C 0° to 55° C Weight < 1.5kg < 1.5kg < 1.5kg 5.5 VA 5.5 VA Burden on Auxiliary supply Not applicable Output Contact 2 C/O Contacts (S/R) 2 C/O Contacts (S/R) 2 C/O Contacts (S/R) Construction Drawout Drawout Drawout Dim W x H x D in mm 71 x 158 x 224 71 x 158 x 224 71 x 158 x 224 Panel Cutout 62 x 142 62 x 142 62 x 142 BACK 5/5 WIRING DIAGRAM CURRENT SENSING RELAYS 5 MC11A ME11A SC14S 5/6 BACK ORDERING INFORMATION CURRENT SENSING RELAYS Model MC11A Description Single Pole Over current or Earth Fault Relay Catalogue No. MC11A 00 Catalogue No. Selection Guide for MC11A 5 Model ME11A Description Single Pole Sensitive Earth Fault Relay Catalogue No. ME11A 00 Catalogue No. Selection Guide for ME11A Model SC14S Description Instantaneous Earth Fault Relay Catalogue No. SC14S 00 Catalogue No. Selection Guide for SC14S BACK 5/7 TECHNICAL DATA NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY ✦ ✦ ✦ ✦ Easy Setting through front panel DIP Switches. LED indication for Power ON and trip status. Test feature - helps maintenance. Compact, Light weight helps in reducing panel size & thickness. Model MND11 RRS MV11 Description Neutral Displacement Generator Load Sharing 1 Ph U/V OR O/V Device Code 59 Vo 95 27 OR 59 Design Microcontroller Based Static Microcontroller Based Functions Available Voltage relay for E/F Protection Active / Reactive power selection Lowset U/V -Vs of generator earthed thro Over Power alarm Highset U/V -Vhs OR neutral earthing transformer Load Sharing Lowset O/V -Vs Frequency control Highset O/V -Vhs 5 Settings Other Features Fault voltage Vs- U/V Vs = 95-20% step 5% 2% - 32% of Vn step 2% U/V Vhs = 90-20% step 10% Alarm voltage Vis- O/V Vs = 105-180% step 5% 2% - 32% of Vn step 2% O/V Vhs = 110-180% step 10% Time Characteristics available- Time Characteristics available- Inverse time or Definite time Inverse time or Definite time TMS : 0.1 - 1.6 Step 0.1 TMS : 0.1 - 1.6 Step 0.1 LED indication for power ON LED indication Site selectable U/V OR O/V time characteristics, trip Site selectable Trip time char. Test feature Highset can be disabled Third harmonics rejection 26db Burden on PT 0.25 VA 5 VA Burden on CT Not applicable Operating temp 0° to 55° C 0° to 55° C 0° to 55° C Weight < 1.5kg < 1.5kg < 1.5kg 5.5 VA 8.5 VA 5.5 VA Burden on Auxiliary supply 5 VA 0.075 VA on PT Not applicable Output Contact 1No+2 C/O Contacts (S/R) 3 N/O 2 C/O Contacts (S/R) Construction Drawout Drawout Drawout Dim W x H x D in mm 71 x 158 x 224 71 x 158 x 224 71 x 158 x 224 Panel Cutout 62 x 142 62 x 142 62 x 142 5/8 BACK WIRING DIAGRAM NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY 5 MND11 RRS MV11 BACK 5/9 ORDERING INFORMATION NEUTRAL DISPLACEMENT RELAY, GENERATOR LOAD SHARING RELAY, UNDER VOLTAGE OR OVER VOLTAGE RELAY Model Description Catalogue No. MND11 Neutral Displacement Relay 20-110V MND11A00000 MND11 Neutral Displacement Relay 88-264V MND11B00000 RRS Load Sharing Relay 20-110V ESRRSAXX000 RRS Load Sharing Relay 88-264V ESRRSBXX000 MV11A Single Phase Under Voltage or Over Voltage Relay MV11A 5 00 00 Catalogue No. Selection Guide for MV11A 5/10 BACK TECHNICAL DATA SECONDARY RELAYS Trip Circuit Supervision Relay Timer Relay and PT Fuse Failure Relay ✦ ✦ ✦ ✦ ✦ Easy Setting through front panel DIP Switches. Indication for Power ON and trip status. Test feature - helps maintenance. Compact, Light weight helps in reducing panel size & thickness. Low Power Burden Model TCS01 MTM01 PTF03 5 Description Trip Circuit supervision Timer Relay PT Fuse Failure Relay Device Code 95 ABC 2T 60 Design Static Microcontroller Based Static Functions Available Post Close Supervision Programmable as Delay on 3 Phase PT fuse failure Pre Close Supervision Pick up or Drop off Rating Not applicable Not applicable 110V AC PT Settings Trip coil supply 110 - 220V AC 15 - 999 mS step 1 mS Not applicable OR 24 - 48 - 110 - 220V DC 1 - 9.99 S step 10mS Operation time 500+/-100mS 10 - 99.9 S step 100mS Reset time < 150 mS 100 - 999 S step 1S Same Relay for all Rating Password protection available LED Indication for each phase Trip supply U/V indication Contacts programmable Relay trip status CB ON/OFF status indication as S/R or H/R Other Features Operation time 7mS Self powered High speed operation Burden on CT Not applicable Not applicable Not applicable Burden on PT Not applicable Not applicable <0.5 VA per phase on PT Operating temp 0° to 55° C 0° to 55° C 0° to 55° C Weight < 1.5kg < 1.5kg < 1.5kg Burden on Auxiliary supply 10 VA 6 VA Not applicable Output Contacts 2 C/O Contacts (S/R) 2 N/O + 2 N/C Per timer 2 C/O Contacts (S/R) Construction Drawout Drawout Drawout Dim W x H x D in mm 71 x 158 x 224 71 x 158 x 224 71 x 158 x 224 Panel Cutout 62 x 142 62 x 142 62 x 142 BACK 5/11 WIRING DIAGRAM SECONDARY RELAYS 5 TCS01 MTMO1 PTFO3 5/12 BACK ORDERING INFORMATION SECONDARY RELAYS Model Description Catalogue No. TCS01 Trip Circuit Supervision Relay 20-110V AC/DC MCS01A00000 TCS01 Trip Circuit Supervision Relay 80-264V AC/DC MCS01B00000 MTM01A Timer Relay 20-110V AC/DC MTM01A00000 MTM01B Timer Relay 80-264V AC/DC MTM01B00000 PTF03 PT Fuse Failure Relay MTF03X00000 5 BACK 5/13 TECHNICAL DATA POWER FACTOR CONTROL AND MONITORING RELAYS Power Factor Controller Relay and Voltage & Power Factor Monitoring Relay ✦ ✦ ✦ ✦ On line display of system PF. Easy setting of power factor and C/K ratio from front panel. LED indication for Alarm code, No. of Banks selected, PF status-lead / lag / unity, Auto / Manual mode. DIP switches selection for No. of banks / time relay / bank ratios. Model PFC8 PFC14 MVP01 Description Power Factor Controller Power Factor Controller Voltage / Power Factor monitor Design Microcontroller Based Microcontroller Based Microcontroller Based Functions Available Automatic PF controller Automatic PF controller U/V, O/V trip and leading PF alarm Can control upto- Can control upto- 8 Capacitor Banks 14 Capacitor Banks 5 Device Code Settings Other Features PF : 0.8 Lag - 0.95 Lead PF : 0.8 Lag - 0.95 Lead U/V 75% to 90% step 1% Switching time 10-20-40-60 S Switching time 10-20-40-60 S OV 105% to 120% step 1% Threshold reactive current Threshold reactive current setting 0.5 - 1A reactive setting 0.5 - 1A reactive leading PF alarm time 20 Sec. Capacitor Bank Selection- Capacitor Bank Selection- U/V - O/V trip time 10 Sec. 4-5-6-7-8 Banks 4-5-6-7-8-10-12-14 Banks Display of PF Measurement Display of PF Measurement Display of Power Factor Auto / Manual Selection Auto / Manual Selection LED indication for O/V trip, U/V trip, Disconnection of Capacitors Disconnection of Capacitors PF status- lead / lag, lead PF alarm during over voltage & Power failure during over voltage & Power failure 1A / 5A field selectable Alarm contact for under/over Alarm contact for under/over compensation, over voltage, under load compensation, over voltage, under load Burden on CT 0.3 VA 0.3 VA Burden on PT 10 VA 10 VA Operating temp 0° to 55° C 0° to 55° C 0° to 55° C Weight < 2kg < 2kg < 2kg Output Contacts 8 NO 14 NO 2 N/O for lead PF (self reset) 15 VA 2 N/O for O/V (1 self/1 manual) 2 C/O for U/V (manual reset) Dim W x H x D in mm 144 x 144 x 110 144 x 144 x 110 144 x 144 x 110 Panel Cutout 138 x 138 138 x 138 138 x 138 Auxiliary supply 415V AC 415V AC 110V AC 5/14 BACK WIRING DIAGRAM POWER FACTOR CONTROL & MONITORING RELAYS 5 PFC14 PFC8 MVP01 BACK 5/15 ORDERING INFORMATION POWER FACTOR CONTROL & MONITORING RELAYS Model Description Catalogue No. PFC8 Eight Stage APFC Relay MPF08XOOOOO PFC14 Fourteen Stage APFC Relay MPF14XOOOOO MPV01 Voltage & PF Monitoring Relay MVP01X00000 5 5/16 BACK TECHNICAL DATA MOTOR PROTECTION RELAY ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, trip count and trip data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature helps maintenance. Easy operation by 5 push buttons. RS 485 port for serial communication with MSCON user friendly software. Model MM30 5 Description Motor Protection Device Code 49, 51lr, 46, 37, 50/51, 64, sTnO, LTR Design Numeric Functions Available Thermail O/L and Pre-alarm Locked Rotor Current unbalance, phase reversal, phase loss Over Current Earth Fault Repeat and prolonged starts Restart Inhibition No load running Blocking Function Other Features Auto setting 1 A or 5 A site selectable (Default 5 Amp) Selectable motor time constant (1 - 60 min) Display of parameters Built in self supervision RS485 PORT Burden on CT 0.2 VA for 5A, 0.01 VA for 1A Burden on PT Not applicable Operating temp 10° to 60° C Weight < 2kg Burden on Auxiliary supply 8.5 VA Output Contacts 4 C/O + 1 C/O for self supervision Construction Drawout Dim W x H x D in mm 121 x 158 x 224 Panel Cutout 113 x 142 BACK 5/17 WIRING DIAGRAM MOTOR PROTECTION RELAY 5 MM30 5/18 BACK ORDERING INFORMATION MOTOR PROTECTION RELAY Model Description Catalogue No. MM30 Motor Protection Relay 20-110V EMM30AXX000 MM30 Motor Protection Relay 88-264V EMM30BXX000 5 BACK 5/19 TECHNICAL DATA GENERATOR PROTECTION RELAYS Multifunction Generator Protection Relays and Percentage Biased Generator Differential Relay ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature help maintenance Easy operation by 5 push buttons. RS 485 port for serial communication with MSCOM User friendly software. Model IM3GV IM30G MD32G Description Generator Protection Generator Protection Generator Differential Device Code 50/51V, 49,46,27,59,81,40,32,37 50/51, 46, 64S, 40, 32 87, 50/51, 50LBB, 64S / 87N Design Numeric Numeric Numeric Functions Available Voltage rest. O/C Highset Lowset O/C Generator Differential Trip time char. NI, Def time Highset O/C Bias % with dual adjustable slope Thermal Image Stator E/F Over Current Lowset Negative sequence Negative Sequence Stator E/F Highset Negative sequence Reverse Power CB Failure protection 5 Under voltage, Over frequency Loss of field, Reverse Power Low forward power, CB Failure protection Other Features 1 A or 5 A site selectable 1 A or 5 A site selectable 1 A or 5 A site selectable Display of Parameters Display of Parameters Display of Parameters Built in Self supervision Built in Self supervision Wave form capture feature RS485 Port, Blocking Function RS485 Port, Blocking Function Built in Self supervision, RS485 Port Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A Burden on PT 0.04 VA 0.04 VA Not applicable Burden on Auxiliary supply 8.5 VA 8.5 VA 8.5 VA Operating temp 10° to 60° C 10° to 60° C 10° to 60° C Weight < 2kg < 2kg < 2kg Output Contacts 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 1 C/O for self supervision 1 C/O for self supervision 1 C/O for self supervision Construction Drawout Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224 Panel Cutout 113 x 142 113 x 142 113 x 142 5/20 BACK WIRING DIAGRAM GENERATOR PROTECTION RELAYS 5 IM3GV IM30G MD32G BACK 5/21 ORDERING INFORMATION GENERATOR PROTECTION RELAYS Model 5 Description Catalogue No. IM3GV Generator Protection Relay 20-110V EI3GVAXX000 IM3GV Generator Protection Relay 88-264V EI3GVBXX000 IM30G Generator Protection Relay 20-110V EI30GAXX000 IM30G Generator Protection Relay 88-264V EI30GBXX000 MD32G Differential Relay for Generator 20-110V ED32GAXX000 MD32G Differential Relay for Generator 88-264V ED32GBXX000 5/22 BACK TECHNICAL DATA SYNCHRONISING RELAYS Generator Synchronising / Synchrocheck relays ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, event count & event data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature help maintenance. Easy operation by 5 push buttons. RS 485 port for serial communication with MSCOM User friendly software. Model SPM21 SCM21 5 Description Auto Synchronising Relay Synchronising Check Relay Device Code 25 25 Design Numeric Numeric Functions Available Auto Synchronising with Synchro Check with Adjustable voltage, Adjustable voltage Adjustable Frequency, Adjustable Frequency Adjustable Phase angle, Adjustable Phase angle Adjustable Reclose time, Adjustable Reclose time, Check Synch / Bus Live / Dead operation Dead line / Dead bus modes of operation, Speed Regular Control, Over voltage protection, Under voltage Voltage Regulator Control, protection, Over Frequency Protection Digital inputs to monitor Under frequency protection, CB position Digital inputs to monitor CB position Rating 110V - 125 V PT input 110V - 125 V PT input Other Features Display of Parameters, Display of Parameters, Built in self supervision, Built in self supervision, RS485 Port RS485 Port Burden on PT 0.04 VA 0.04 VA Operating temp 10° to 60° C 10° to 60° C Weight < 2kg < 2kg Burden on Auxiliary supply 8.5 VA 8.5 VA Output Contacts 5 C/O 5 C/O Construction Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 Panel Cutout 113 x 142 113 x 142 BACK 5/23 WIRING DIAGRAM SYNCHRONISING RELAYS 5 SPM21 Connection diagram of 1 bus with 2 lines Connection diagram of 1 bus with 1 line SCM21 5/24 BACK ORDERING INFORMATION SYNCHRONISING RELAYS Model Description Catalogue No. SPM21 Auto Synchronising Relay 20-110V EPM21A00000 SPM21 Auto Synchronising Relay 88-264V EPM21B00000 SCM21 Synchrocheck Relay 20-110V ESC21A00000 SCM21 Synchrocheck Relay 88-264V ESC21B00000 5 BACK 5/25 TECHNICAL DATA VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY 3 Phase voltage / frequency and Load shedding Relay 3 Phase voltage / frequency and zero sequence voltage Relay ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature help maintenance. Easy operation by 5 push buttons. RS 485 port for serial communication with MSCOM User friendly software. Model UFD34 UM30A DM30 Description 3 Ph Voltage & Freq. Relay 3 Ph Voltage & Freq. Relay 3 Ph Dir O/C & E/F + Highset Device Code 81, 27, 59, df/dt, de/dt 81, 27, 59, V/Hz, 59d, 59s, 59Uo 50/67 RYBN, 50 LBB Design Numeric Numeric Numeric Functions Available Frequency-4 stages selectable Over exitation-2 stages Low Set Dir O/C as under or over or under/over Frequency-2 stages selectable Highset Dir O/C Voltages - 2 stages selectable as under or over or under/over Low Set Dir E/F Rate of change of frequency Voltages - 2 stages selectable Trip time Char : NI, VI, EI, Def time protection df / dt - 2 Stages as under or over CB Failure Function Blocking function Zero Sequence - 2 Stages MTA Setting = 0-359° Blocking function 1A or 5A site selectable 100 - 125V PT input 5 Rating 100 - 125V PT input 100 - 125V PT input Other Features Display of Parameters Display of Parameters Display of Parameters Built in Self supervision Built in Self supervision Built in Self supervision RS485 Port communication RS485 Port communication RS485 Port communication Burden on CT Not applicable Not applicable 0.2 VA for 5A, 0.01 VA for 1A Burden on PT 0.04 VA 0.04 VA 8.5 VA Operating temp 10° to 60° C 10° to 60° C 10° to 60° C Weight < 2kg < 2kg < 2kg Burden on Auxiliary supply 8.5 VA 8.5 VA 0.04 VA Output Contacts 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 4 C/O, S/R or H/R or Time del 1 C/O for self supervision 1 C/O for self supervision 1 C/O for self supervision Construction Drawout Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 121 x 158 x 224 Panel Cutout 113 x 142 113 x 142 113 x 142 5/26 BACK WIRING DIAGRAM VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY 5 UFD34 UM30A DM30 BACK 5/27 ORDERING INFORMATION VOLTAGE / FREQUENCY RELAYS, DIRECTIONAL O/C, E/F RELAY Model 5 Description Catalogue No. UFD34 Frequency Relay 20-110V EFD34A00000 UFD34 Frequency Relay 88-264V EFD34B00000 UM30 U/V Relay with Neutral Monitoring 20-110V EUM30A00000 UM30 U/V Relay with Neutral Monitoring 88-264V EUM30B00000 DM30 3 Phase O/C and E/F Relay 20-110V (Directional) EDM30AXX000 DM30 3 Phase O/C and E/F Relay 88-264V (Directional) EDM30BXX000 5/28 BACK TECHNICAL DATA TRANSFORMER PROTECTION RELAY, CAPACITOR BANK PROTECTION RELAY Percentage Biased Transformer Differential Relay 3 Phase Thermal + Over Current + Earth Fault Relay for transformer protection ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, trip count & trip data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature help maintenance. Easy operation by 5 push buttons. RS 485 port for serial communication with MSCOM User friendly software. Model MD32T IM30T DIN30C 5 Description Transformer Differential + 3 Ph O/C, E/F + Thermal Restricted E/F 3 Ph O/C, E/F For capacitor banks Device Code 87 RYB, 87N 50/51 RYBN, 49, 46, 12t 51/51 RYBN, 46, 37 1o Design Numeric Numeric Numeric Functions Available Lowset Differential Lowset O/C O/C - 0.1 - 10 ln Lowset Op time : <=30mS Highset O/C E/F - 0.1 - 5 ln Highset Differential Lowset E/F negative Seq - 10% - 75% ln Highset Op time : 6-20mS Highset E/F undercurrent - 10% Restricted Earth Fault Thermal Overload unbalance - 2% - 50% Dual slope Bias Lowset current unbalance with 2nd harmonic restraint setting Highset current unbalance 5th harmonic restraint setting Inrush Energy protection Auto correction of CT Ratio CB Failure function Zero sequence compensation Blocking function Blocking function Other Features Display of Parameters Display of Parameters Display of Parameters Built in Self supervision Built in Self supervision RS 485 port RS485 PORT RS485 Port LED indication for Trip / Power ON 1 A OR 5 A site selectable 1 A OR 5 A site selectable Test feature Waveform capture feature Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A Operating temp 10° to 60° C 10° to 60° C 10° to 60° C Weight < 2kg < 2kg < 2kg Burden on Auxiliary supply 8.5 VA 8.5 VA Output Contacts 5 C/O, S/R or H/R or Time del 5 C/O, S/R or H/R or Time del 2 C/O contacts, S/R or H/R Construction Drawout Drawout DIN rail mounting Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 105 x 85 x 70 Panel Cutout 113 x 142 113 x 142 Not applicable BACK 5/29 WIRING DIAGRAM TRANSFORMER PROTECTION RELAYS, CAPACITOR BANK PROTECTION RELAY 5 MD32T IM30T DIN30C 5/30 BACK ORDERING INFORMATION TRANSFORMER PROTECTION RELAYS, CAPACITOR BANK PROTECTION RELAY Model Description Catalogue No. MD32T Differential Relay for Transformer 20-110V ED32TAXX000 MD32T Differential Relay for Transformer 88-264V ED32TBXX000 IM30T 3 Phase O/C and E/F Relay for Transformer 20-110V ED30TAXX000 IM30T 3 Phase O/C and E/F Relay for Transformer 88-264V ED30TBXX000 DIN30C Capacitor Bank Protection Relay 20-110V DIN mounting ED30CAXX000 DIN30C Capacitor Bank Protection Relay 88-264V DIN mounting ED30CBXX000 BACK 5/31 5 TECHNICAL DATA CONTROL & SUPERVISION RELAYS Power Management Relay Multifunction 3 Phase Measuring Instrument ✦ ✦ ✦ ✦ ✦ ✦ Display of various parameters, event count & event data on 8 digit alphanumeric display. Separate LEDs for various fault indication. Four user programmable output relays. Built in self supervision & self testing feature help maintenance. Easy operation by 5 push buttons. RS 485 port for serial communication with MSCOM User friendly software. Model MW33 MU30 Description Power management Measurement Device Code 81, 27, 59, PF, P, QL, QC Measure Design Numeric Numeric Functions Available Frequence 2 stages, Actual measurements of Voltage 2 stage, Freq, I, V, PF, Power factor 2 stage, Power - Active / Reactive / Apparent Active power 2 stage, Energy - Active / Reactive Capacitor reactive power 2 stage. Maximum Demand 5 Actual measurement of Freq, V, I, PF, active power, reactive power. Other Features Display of Parameters, Display of Parameters, MD recording & data logging Record of last event RS485 Port, Event recording RS485 Port, Event recording, Event counter, MD recording, Oscillographic wave form capture Burden on CT 0.2 VA for 5A, 0.01 VA for 1A 0.2 VA for 5A, 0.01 VA for 1A Burden on PT 0.04 VA 0.04 VA Operating temp 10° to 60° C 10° to 60° C Weight < 2kg < 2kg Burden on Auxiliary supply 8.5 VA max 8.5 VA max Output Contacts 5 C/O 5 C/O Construction Drawout Drawout Dim W x H x D in mm 121 x 158 x 224 121 x 158 x 224 Panel Cutout 113 x 142 113 x 142 5/32 BACK WIRING DIAGRAM CONTROL AND SUPERVISION RELAYS 5 MW33 MU30 BACK 5/33 ORDERING INFORMATION CONTROL AND SUPERVISION RELAYS Model Description Catalogue No. MW33 Power Management Relay 20-110V EMW33AXX000 MW33 Power Management Relay 88-264V EMW33BXX000 MU30 Measuring Relay 20-110V EMU30AXX000 MU30 Measuring Relay 88-264V EMU30BXX000 5 5/34 BACK TECHNICAL DATA REVERSE POWER RELAY Model MRP11 Description Reverse Power Relay Design Micro-control based Functions Available Instantaneous and Adjustable time relay 5 Powerful DFT Algorithm Field selectable voltage rating LED Indicators Other Features Compact size Flush mounting on panel Burden on CT Not applicable Burden on PT PT - less than 0.25VA Operating temp 0° to 60° C Weight approx. 1kg Burden on Auxiliary supply less than 8 VA Output Contacts 1 C/O + 1 NO Contacts (self reset type) Construction Drawout Dim W x H x D in mm 71 x 158 x 204 Panel Cutout 142 x 62 BACK 5/35 WIRING DIAGRAM REVERSE POWER RELAY 5 ORDERING INFORMATION REVERSE POWER RELAY Model MRP11 Description Reverse Power Relay Catalogue No. MRP11 00 Catalogue No. Selection Guide for MRP11 5/36 BACK ORDERING INFORMATION OTHER RELAYS Model Description Catalogue No. MX7/5 Matrix Interface Module 20-110V 99M75A000 MX7/5 Matrix Interface Module 88-264V 99M75B000 MC-R Data Rec. & Comm. Module 20-110V 99MCRA000 MC-R Data Rec. & Comm. Module 88-264V 99MCRB000 REX Expansion Module 20-110V 99REXA000 REX Expansion Module 88-264V 99REXB000 REX Expansion Module 20-110V 99REXA001 REX Expansion Module 88-264V 99REXB001 CPSC RS232-485 Converter 99CPSC00 MSCOM Communication Software BACK 99MSCOM00 5/37 5