Universal Temperature Converter ED2-UT-Ex2 Assembly Features • • • • • • • 2-channel isolated barrier 24 V DC supply Thermocouple or RTD input Current output 0/4 mA ... 20 mA Configurable by PACTware Line fault (LFD) and sensor burnout detection Internal cold junction compensation Front view ED2-UTEx2 LED red: Fault signal channel 1 CH. 1 FAULT CH. 2 LED red: Fault signal channel 2 Function This isolated barrier is used for intrinsic safety applications. LED green: Power supply PWR The device converts RTD input signals or thermocouple input signals in the hazardous area to 0/4 mA ... 20mA signals in the safe area. Programming jack For temperature measurements with thermocouples the cold junction module E-CJC is used to enable cold junction compensation. PRGRM. If required the device can be used as a dual output single channel unit, using channel 1 input. The cold-junction temperature is measured by channel 1, so if only one channel is to be used with a thermocouple, it must be channel 1. A fault is indicated by LEDs acc. to NAMUR NE44 and by user-configured fault indication outputs. The device is easily configured by the use of the PACTware configuration software. Release date 2012-05-22 12:20 Date of issue 2014-04-29 118828_eng.xml Connection ED2-UT-Ex2 1 E-CJC - d2 + T T 2 + d30 - z30 d4 T 1 2 T d8 + - d6 - d32 z32 z2 + z4 T T T z8 z6 z14d14+ 24 V DC Zone 0, 1, 2 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 1 Technical data ED2-UT-Ex2 General specifications Signal type Analog input Supply Connection d14+, z14- Rated voltage 20 ... 30 V DC Ripple within the supply tolerance Power consumption ≤3W Input Connection channel 1: d2, d4, d6, d8 channel 2: z2, z4, z6, z8 RTD type Pt100 (EN 60751: 1995) type Ni100 (DIN 43760) Measuring current approx. 400 µA with RTD Types of measuring 2-, 3-, 4-wire connection Lead resistance ≤ 50 Ω per lead Measuring circuit monitoring line fault Thermocouples type B, E, J, K, N, R, S, T (IEC 584-1: 1995), type L (IEC 584-1: 1989) Cold junction compensation external and internal , see connection diagram Measuring circuit monitoring sensor breakage Resistor Measurement range 0 ... 400 Ω Voltage Measurement range -240 ... 240 mV Output Connection channel 1: d30+, z30channel 2: d32+, z32- Current range 0/4 ... 20 mA Load ≤ 500 Ω Output Analog current output Fault signal in case of input signal overrange 20.5 mA Line fault detection downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43) Transfer characteristics Deviation After calibration Pt100: ± (0.01 % of measurement value in K + 0.05 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.05 % of span + 1 K (1.2 K for types R and S)) this includes ± 0.8 K error of the cold junction compensation mV: ± (50 µV + 0.1 % of span) potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes errors due to lead resistance)) Influence of ambient temperature deviation of CJC included: Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ∆Tamb*) thermocouple: ± (0.02 K + 0.004 % of measurement value in °C + 0.006 % of span)/K ∆Tamb*) *) ∆T amb = ambient temperature change referenced to 23 °C (296 K) Influence of supply voltage Influence of load < 0.01 % of span ≤ 0.001 % of output value per 100 Ω Electrical isolation Output/power supply Output/Output Release date 2012-05-22 12:20 Date of issue 2014-04-29 118828_eng.xml Directive conformity functional insulation, rated insulation voltage 50 Veff functional insulation, rated insulation voltage 50 Veff Electromagnetic compatibility Directive 2004/108/EC The device has been used for the same applications for several years. It therefore features an appropriate electromagnetic field immunity. The device must not be used in new plants. Conformity Insulation coordination EN 50178 Electromagnetic compatibility NE 21:2006 Degree of protection IEC 60529 Ambient conditions Ambient temperature -20 ... 60 °C (-4 ... 140 °F) Mechanical specifications Degree of protection IP20 Connection 48-pin plug connector acc. to DIN 41612 , series 2 , type F , z, b and d provided Mass approx. 200 g Dimensions 20 x 128 x 193 mm (0.8 x 5 x 7.6 in) Construction type Eurocard 100 x 160 mm (3.9 x 6.3 in) acc. to DIN 41494, front panel 4TE Mounting in 19" rack Coding a15/a27 Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 2 Technical data ED2-UT-Ex2 Data for application in connection with Ex-areas EC-Type Examination Certificate BAS 00 ATEX 7044 X , for additional certificates see www.pepperl-fuchs.com Group, category, type of protection Input Voltage Current Power Supply Maximum safe voltage Output Maximum safe voltage Electrical isolation Input/Other circuits ¬ II (1)GD [Ex ia] IIC, [Ex iaD] (-20 °C ≤ Tamb ≤ 60 °C) [circuit(s) in zone 0/1/2] Ex ia IIC Uo 11 V Io 33 mA Po 90 mW (linear characteristic) Um 250 V (Attention! The rated voltage is lower.) Um 250 V (Attention! The rated voltage is lower.) safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Directive conformity Directive 94/9/EC EN 60079-0:2006, EN 60079-11:2007, EN 61241-0:2006, EN 61241-11:2005 General information Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Accessories optional accessories: - cold junction module E-CJC - programming adapter K-ADP-USB - configuration software PACTwareTM Release date 2012-05-22 12:20 Date of issue 2014-04-29 118828_eng.xml Designation Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 3