Part 9 Development codes

advertisement
Part 9 Development codes
9.1
Preliminary
(1)
Development codes are codes for assessment where identified as an applicable code in Part 5–
Tables of assessment.
(2)
Statewide codes are included in all Queensland planning schemes.
(3)
Use codes and development codes are specific to each planning scheme area.
(4)
The following are the statewide codes for the planning scheme:
(5)
(6)
(a)
Community residence code;
(b)
Forestry for wood production code;
(c)
Reconfiguring a lot (subdividing one lot into two lots) and associated operational work
code.
The following are the use codes for the planning scheme:
(a)
Dual occupancy and Dwelling house code;
(b)
Home based business code;
(c)
Multiple dwelling, Rooming accommodation and Short-term accommodation code;
(d)
Relocatable home park, Residential care facility and Retirement facility code;
(e)
Roadside stall code;
(f)
Sales office code;
(g)
Telecommunications facility code.
The following are the development codes for the planning scheme:
(a)
Advertising device code;
(b)
Filling and excavation code;
(c)
Infrastructure code;
(d)
Landscape code;
(e)
Management of emissions and hazardous activities code;
(f)
Reconfiguring a lot code;
(g)
Servicing, access and parking code.
9.2
Statewide codes
9.2.1
Community residence code
(1)
The purpose of the community residence code is for assessing a material change of use for a
community residence.
Table 9.2.1.1–Community residence for self-assessable development only
Acceptable outcomes (AO)
A01
The maximum number of residents is seven.
AO2
One support worker is permitted to reside on the premises at any one time.
AO3
The maximum number of support workers attending any daytime activity shall not exceed
seven people over a 24 hour period.
AO4
Resident and visitor parking is provided for a minimum of two vehicles. One vehicle space
must be dedicated for parking for support services.
Part 9 Development codes—9.2.1 Community residence code
Logan Planning Scheme 2015 version 1.1
P9-1
9.2.2
Forestry for wood production
9.2.2.1
Application
This code applies to assessing a material change of use for development involving cropping (where
forestry for wood production) in the rural zone.
9.2.2.2
Purpose
(1)
The purpose of the code is to ensure forestry for wood production is assessed with equal regard
to other forms of cropping, to guarantee long-term harvest and minimise impacts.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
the use is appropriately located and setback from areas of environmental interest and
existing infrastructure;
(b)
the impacts on adjoining land uses are minimised;
(c)
the risk of fire is minimised;
(d)
expected harvest cycles, volumes, timescales and haulage routes, plus proposed wildfire
management and the location of supportive infrastructure are known by the local
government, where development is assessable.
9.2.2.3
Criteria for assessment
Part A–Criteria for assessable development
Table 9.2.2.3.1–Forestry for wood production code: self-assessable and assessable
development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Setbacks
PO1
The establishment of the forest for wood
production is located to minimise impacts (such
as shading and falling trees) on infrastructure
and areas of environmental interest.
AO1.1
The establishment of the forest for wood
production is setback from existing infrastructure
and areas of environmental interest in
accordance with Table 9.2.2.3.2—Forestry for
wood production setback distances.
AO1.2
No cultivation and planting for wood production is
to occur in setback areas identified in Table
9.2.2.3.2—Forestry for wood production setback
distances. Road and track establishment and
maintenance can occur.
AO1.3
Self-propagated seedlings (wildlings) generated
from the forest for wood production are
eradicated from the setback areas identified in
Table 9.2.2.3.2—Forestry for wood production
setback distances.
Part 9 Development codes—9.2.2 Forestry for wood production
Logan Planning Scheme 2015 version 1.1
P9-2
Performance outcomes
Acceptable outcomes
Impacts on soil structure, fertility and stability
PO2
The impacts of the forest for wood production on
soil structure, fertility and stability are minimised
through appropriate management of the site.
AO2.1
The establishment and maintenance (including
associated tracks and roads) of the forest for
wood production utilises one or more of the
following methods:
(a) mechanical strip cultivation on the contour,
spot cultivation or manual cultivation is used
for establishment on slopes greater than 10
percent and less than 25 percent;
(b) either spot cultivation or manual cultivation is
used for establishment on slopes equal to or
greater than 25 percent;
(c) tracks and roads are established away from
natural drainage features and areas that are
subject to erosion and landslips.
AO2.2
Any part of a track or road established and
maintained as part of the forest for wood
production is appropriately drained and adopts
the following measures:
(a) establish and maintain a stable surface;
(b) drain the track or road with crossfall drainage
(preferably with a slope greater than four
percent) or by shaping the track or road to a
crown so that water drains to both of its
sides;
(c) establish and maintain drainage structure to
convey water away from the track or road
formation (for example, crossdrains, mitre
drains, turnouts and diversion drains or relief
culverts).
AO2.3
Drainage water from tracks and roads
established and maintained as part of the forest
for wood production is directed away from
exposed soils, unstable areas, and towards
undisturbed ground and areas with stable
surfaces.
Fire risk
PO3
The risk of fire to adjoining premises and
infrastructure is minimised through the provision
of firebreaks and fire tracks and roads.
AO3.1
Firebreaks are established and maintained:
(a) between the forest for wood production ,
adjoining premises and existing
infrastructure;
(b) at a minimum width from the base of the
outside trees in accordance with Table
9.2.2.3.3—Forestry for wood production
firebreak distances;
(c) that are free of flammable material that is
greater than one metre high;
(d) to be accessible and trafficable for fire
suppression vehicles.
Part 9 Development codes—9.2.2 Forestry for wood production
Logan Planning Scheme 2015 version 1.1
P9-3
Performance outcomes
Acceptable outcomes
AO3.2
Fire access tracks and roads are established and
maintained:
(a) to a minimum width of four metres;
(b) that are accessible;
(c) that ensure no part of a plantation is more
than 250 metres from a fire access track or
road.
For assessable development
Cropping harvest, haulage and wildfire management
PO4
Local government are informed of the expected
cropping harvest cycles, volumes, timescales
and haulage routes, plus proposed wildfire
management and location of supportive
infrastructure.
AO4
When the forest for wood production area is
greater than 10 hectares a management report is
attached to the development application that
contains the following information:
(a) expected harvest cycles and estimated
harvest timescale;
(b) an estimated haulage route plan identifying
likely local roads for transporting the harvest
to the primary destination/s;
(c) proposed methods and supporting
infrastructure location for managing wildfire
(including an area map of the property
location, adjacent roads and tracks, property
entrances, location of fire access tracks and
turnaround on the property and location of
water points in the area).
Table 9.2.2.3.2—Forestry for wood production setback distances
Aspect
Distance (measured from the base of the tree)
Areas of environmental interest
Top of a defining bank of streams (gully, creek or Stream order 1 to 2: 5 metres; or
river) that are represented on the 1:100,000
Stream order 3 to 5: 10 metres; or
topographic map series in accordance with the
Stream order 6: 20 metres.
stream order classification system
State-owned protected areas and forest reserves 10 metres
under the Nature Conservation Act 1992
Protected vegetation under the Vegetation
Management Act 1999
10 metres
Infrastructure
Dwellings
100 metres or such distance that ensures the
Dwelling is consistent with the requirements of
AS3959–2009 and the Building Code of Australia
Machinery sheds
25 metres or 1.5 times the maximum anticipated
height of the tree at harvest whichever is the
greater
Part 9 Development codes—9.2.2 Forestry for wood production
Logan Planning Scheme 2015 version 1.1
P9-4
Transmission lines and above-ground pipelines
(excluding infrastructure servicing only the farm)
not subject to an easement
25 metres or 1.5 times the maximum anticipated
height of the tree at harvest, whichever is the
greater
Table 9.2.2.3.3—Forestry for wood production firebreak distances
Firebreaks
Firebreaks
Distance
Forestry for wood production activities less than
40 hectares
7 metres
Forestry for wood production of 40 hectares to
100 hectares
10 metres
Forestry for wood production greater than 100
hectares
20 metres, or a 10 metre break that is free of
flammable material that is greater than 1 metre
high followed by a 10 metre fuel reduction area
where forestry for wood production trees are
pruned up to a minimum height of five metres,
commencing once trees are greater than 10
metres in height
9.2.3
(1)
Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
The purpose of the reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code is for assessing requests for compliance assessment for development for
reconfiguring a lot that requires compliance assessment as prescribed in Part 5–Tables of
assessment, section 5.4 under Table 5.4.2–Prescribed level of assessment: reconfiguring a lot.
Note––Development subject to compliance assessment must be able to achieve compliance with the compliance outcomes for
a compliance permit to be issued.
Note––If compliance with the code is not possible, the development cannot be considered for compliance assessment and a
development application for assessable development must be made to the local government as outlined in Schedule 18 of the
Regulation.
Editor's note––For compliance assessment to apply, it is a requirement of Schedule 18(1)(b) of the Sustainable Planning Act
2009 that the size of a lot created is at least the minimum lot size for the zone stated in the planning scheme, a temporary local
planning instrument , a master plan or a preliminary approval to which section 242 of the Act applies. For minimum lot sizes for
each zone and precinct see Table 9.4.5.3.2.
Table 9.2.2.3.1–Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work requiring compliance assessment
Compliance outcomes (CO)
Lot design
CO1
Each lot is to comply with the following frontage requirements:
(a) Column 4 of Table 9.4.6.3.2–Reconfiguring a lot for the relevant zone and/or precinct.
CO2
Each lot is to comply with the following building envelope requirements:
(a) a development envelope area is located in an area cleared of vegetation and is able to
accommodate the buildings and associated firebreak;
(b) a development envelope area is provided above the level of the defined flood event with
a minimum area and dimension specified in Table 8.2.5.3.2–Development envelope
area in the Flood hazard overlay code.
CO3
Each lot is to comply with the following rear lot requirements:
(a) Column 6 of Table 9.4.6.3.2–Reconfiguring a lot for the relevant zone and/or precinct.
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-5
CO4
The reconfiguration ensures that any existing buildings and structures are setback to any
new property boundary as follows1:
Zone (precinct)
Use
Boundary clearance
Front
Rear
Side
Low density residential
zone–Large suburban
precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
Where the height of
a part of the
building or structure
is:
(a) 4.5 or less–
1.5m;
(b) greater than
4.5m but not
more than 7.5m
–2m;
(c) greater than
7.5m–2m plus
0.5m for every
3m or part
exceeding
7.5m.
Low density residential
zone–Small lot
precinct
Other than Dual
occupancy or
Dwelling house
4 metres
4.5
metres
Where the height of
a part of the
building or structure
is:
(a) 4.5 or less–
1.5m;
(b) greater than
4.5m but not
more than 7.5m
–2m;
(c) greater than
7.5m–2m plus
0.5m for every
3m or part
exceeding
7.5m.
Low density residential
zone–Suburban
precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
Where the height of
a part of the
building or structure
is:
(a) 4.5 or less–
1.5m;
(b) greater than
4.5m but not
more than 7.5m
–2m;
(c) greater than
7.5m–2m plus
0.5m for every
3m or part
exceeding
7.5m.
Note––1 For dwelling houses or Dual occupancy in the in the Low density residential zone’s Large suburban precinct, Small lot
precinct, Suburban precinct and Village precinct, the Queensland Development Code (QDC) – MP1.1, MP1.2 or MP1.3 applies.
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-6
Low density residential
zone–Village precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
Where the height of
a part of the
building or structure
is:
(a) 4.5 or less–
1.5m;
(b) greater than
4.5m but not
more than 7.5m
–2m;
(c) greater than
7.5m–2m plus
0.5m for every
3m or part
exceeding
7.5m.
Low density residential
zone–Acreage precinct
All
10 metres
3 metres
3 metres
Low density residential
zone–Small acreage
precinct
All
10 metres
3 metres
3 metres
Low-medium density
residential zone–
Apartment precinct
All
a minimum of
4 metres; or
the building
or structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
3 metres
3 metres
Low-medium density
residential zone–
Townhouse precinct
All
a minimum of
4 metres; or
the building
or structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
3 metres
Where the height of
a part of the
building or structure
is:
(a) 4.5 or less–
1.5m;
(b) greater than
4.5m but not
more than 7.5m
–2m;
(c) greater than
7.5m–2m plus
0.5m for every
3m or part
exceeding
7.5m.
Medium density
residential zone–High
rise precinct
All
a minimum of
6 metres; or
the building
or structure
aligns with
6 metres
6 metres
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-7
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
CO5
Medium density
residential zone–
Medium rise precinct
All
a minimum of
6 metres; or
the building
or structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjacent lots
3 metres
3 metres
Low impact industry
zone
All
(a) 10 metres
from the
primary
street
frontage;
(b) 6 metres
from a
secondary
road
frontage
–
–
Medium impact
industry zone
All
(a) 10 metres
from the
primary
street
frontage;
(b) 6 metres
from a
secondary
road
frontage
–
–
The reconfiguration enables any proposed buildings and structures to comply with boundary
setback requirements as follows2:
Zone (precinct)
Use
Boundary clearance
Front
Rear
Side
Low density residential
zone–Large suburban
precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
3 metres
Low density residential
zone–Small lot
precinct
Other than Dual
occupancy or
Dwelling house
4 metres
4.5
metres
3 metres
Note–– 2 For dwelling houses or Dual occupancy in the in the Low density residential zone’s Large suburban precinct, Small lot
precinct, Suburban precinct and Village precinct, the Queensland Development Code (QDC) – MP1.1, MP1.2 or MP1.3 applies.
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-8
Low density residential
zone–Suburban
precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
3 metres
Low density residential
zone–Village precinct
Other than Dual
occupancy or
Dwelling house
6 metres
6 metres
3 metres
Low density residential
zone–Acreage precinct
All
10 metres
3 metres
3 metres
Low density residential
zone–Small acreage
precinct
All
10 metres
3 metres
3 metres
Low-medium density
residential zone–
Apartment precinct
All
a minimum of
4 metres; or
the building or
structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
3 metres
3 metres
Low-medium density
residential zone–
Townhouse precinct
All
a minimum of
4 metres; or
the building or
structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
3 metres
3 metres
Medium density
residential zone–High
rise precinct
All
a minimum of
6 metres; or
the building or
structure
aligns with
the building
setback of
one or more
existing
adjacent
buildings on
adjoining lots
6 metres
6 metres
Medium density
residential zone–
Medium rise precinct
All
a minimum of
6 metres; or
the building or
structure
aligns with
the building
setback of
one or more
existing
3 metres
3 metres
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-9
adjacent
buildings on
adjoining lots.
Low impact industry
zone
All
10 metres
from the
primary street
frontage;
6 metres from
a secondary
road frontage.
–
–
Medium impact
industry zone
All
10 metres
from the
primary street
frontage;
6 metres from
a secondary
road frontage.
–
–
CO6
The reconfiguration enables proposed buildings and structures to avoid easements, such as
easements for trunk sewer lines. No new lots are created where proposed buildings and
structures cannot be constructed due to existing or planned underground or above ground
infrastructure.
CO7
No new lots are created on land subject to flooding up to and including the defined flood
event (DFE) as identified in the Flood hazard overlay code or an annual exceedance
probability (AEP) of 1 per cent, whichever results in the highest level above Australian
Height Datum (AHD).
CO8
If the land is located within a Designated Bushfire Prone Area, the reconfiguration does not
involve premises identified as being greater than low risk.
CO9
No new lots are created where the existing slope of the land is 15 percent or greater.
Infrastructure
CO10 For premises in a reticulated water area, each lot is connected to the reticulated water
supply system.
or
For premises located outside a reticulated water area, each lot is provided with an alternate
potable water supply source (e.g. rainwater, bore water), with a minimum storage capacity in
accordance with the following:
(a) for a lot on which a Dwelling house is located or is to be located–a minimum storage
capacity of 45,000 litres;
(b) for all other lots–sufficient water storage to, on average over a 30 year period, not
require more than 100 kilolitres of water from external water sources per year.
CO11 For premises located in a sewered area3, each lot is connected to the sewerage service.
or
For premises located outside a sewered area, each lot provides for an effluent treatment
and disposal system in accordance with the following:
(a) the Plumbing and Drainage Act 2002;
(b) the Queensland Plumbing and Wastewater Code.
CO12 Each lot is connected to an electricity supply network as follows:
in accordance with section 3.8–Electricity reticulation standards in planning scheme policy
5–Infrastructure.
CO13 Each lot is connected to a telecommunications network as follows:
Note––3 Sewered area is defined in the Plumbing and Drainage Act 2002 and means a service area for a sewerage service
under the Water Supply (Safety and Reliability) Act 2008.
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-10
(a) in accordance with section 3.9–Gas and telecommunication reticulation standards in
planning scheme policy 5–Infrastructure.
CO14 Infrastructure (water supply, sewerage, roads, stormwater quality and quantity, recreational
parks, land only for community purposes) is designed and constructed to service the lots in
accordance with the following:
(a) Planning scheme policy 5–Infrastructure.
Access
CO15 Each lot has lawful, safe and practical access to the existing road network via:
(a) direct road frontage; or
(b) an access strip (for a rear lot); or
(c) an access easement.
CO16 Where access to a lot is proposed via an access strip or easement, the access strip or
easement:
has a minimum width that complies with the requirements specified in column 6 of Table
9.4.6.3.2–Reconfiguring a lot for the relevant zone and/or precinct; and
(b) is designed and constructed in accordance with the following:
(i) section 3.4.5(10) of planning scheme policy 5–Infrastructure.
CO17 The maximum length of an access strip or easement does not exceed the maximum length
specified in column 6 of Table 9.4.6.3.2–Reconfiguring a lot for the relevant zone and/or
precinct.
CO18 The gradient of an access strip or easement does not exceed 16 percent.
CO19 A driveway crossover to each lot is designed and constructed in accordance with the
following:
section 3.4.5–Design standards for access and driveways of planning scheme policy 5–
Infrastructure.
Stormwater
CO20 Onsite erosion and the release of sediment or sediment-laden stormwater from the premises
is minimised at all times including during construction and complies with part 3.3 of planning
scheme policy 5–Infrastructure.
CO21 Filling or excavation on the premises does not exceed a maximum of one metre vertical
change in natural ground level at any one point.
CO22 Filling or excavation does not cause ponding on the premises or adjoining land in
accordance with part 3 of planning scheme policy 5–Infrastructure.
Part 9 Development codes—9.2.3 Reconfiguring a lot (subdividing one lot into two lots) and associated
operational work code
Logan Planning Scheme 2015 version 1.1
P9-11
9.3
Use codes
9.3.1
Dual occupancy and Dwelling house code
9.3.1.1
Application
(1)
(2)
This code applies to:
(a)
self-assessable and assessable material change of use for a Dual occupancy [including
Dual occupancy (auxiliary unit)] or Dwelling house for which the Dual occupancy and
Dwelling house code is identified in the assessment criteria column in Part 5–Tables of
assessment;
(b)
Building work in accordance with Table 5.7.1–Building work (including house extensions
and class 10 structures).
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
Editor's note––In this code:

a reference to “Dual occupancy (auxiliary unit)” is a reference to a Dual occupancy that is an auxiliary unit. “Auxiliary unit”
is defined in Schedule 1–Definitions;;

unless otherwise specified, a reference to “Dual occupancy” covers both Dual occupancy (auxiliary unit) and any other
form of Dual occupancy.
Editor's note––All relevant assessment criteria for a Dual occupancy (auxiliary unit) or Dwelling house as they relate to overlay
codes have been included in this code to assist with ease of use.
Editor's note––A Dual Occupancy that is not an auxiliary unit is subject to the assessment criteria identified in Part 5
(assessment criteria) for the relevant overlays and zone or local plan.
9.3.1.2
Purpose
(1)
The purpose of the code is to ensure that a Dual occupancy or Dwelling house is compatible
with the surrounding area and to ensure a Dwelling house protects the environment, and the
safety of people and property.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
A Dual occupancy or Dwelling house:
(i)
is designed and sited to protect the amenity of adjoining premises and the
streetscape;
(ii)
provides safe vehicle access to the premises;
(iii) has an attractive built form that is consistent with the character of the applicable
zone, local plan and precinct;
(b)
The subordinate dwelling in a Dual occupancy (auxiliary unit), or secondary dwelling for a
Dwelling house, has a maximum gross floor area of:
(i)
70m2 if in the residential zone category and on a lot that is less than 1,000m 2 in
size; or
(ii)
100m2 otherwise;
(c)
A Dual occupancy (auxiliary unit) or Dwelling house that is located in the Potential and
actual acid sulfate soil area identified on Acid sulfate soils overlay map–OM–01.00:
(i)
avoids the disturbance of acid sulfate soils; or
(ii)
protects ecosystems, the built environment and personal health and safety by
managing any disturbed acid sulfate soils and associated drainage waters;
(d)
A Dual occupancy (auxiliary unit) or Dwelling house that is located in an area identified on
the Biodiversity areas overlap map–OM–02.00 protects and enhances:
(i)
habitat values and biodiversity corridors;
(ii)
native vegetation in the primary and secondary vegetation management area;
(iii) wildlife habitat and movement;
(iv) landscape values;
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-12
(e)
A Dual occupancy (auxiliary unit) or Dwelling house that is located in the Extractive
resource separation area identified on Extractive resources overlay map–OM–04.01:
(i)
does not result in an increase in the number of people living in the separation area;
(ii)
does not impede the safe operation of an extractive industry;
(iii) minimises an adverse effect from an extractive industry on people working or
congregating in the separation area;
(iv) does not compromise the function of the separation area, as a buffer between an
extractive industry and an incompatible use outside the separation area;
(f)
A Dual occupancy (auxiliary unit) or Dwelling house with direct vehicular access to a
transport route identified on Extractive resources overlay map–OM–04.01 does not
adversely affect the safety and efficiency of vehicles transporting extractive resources;
(g)
A Dual occupancy (auxiliary unit) or Dwelling house located in an area identified on Flood
hazard overlay map–OM–05.00 does not result in people and premises being at an
unacceptable risk during a defined flood event;
Editor's note––Where a lot is affected by a Flooding and inundation area, a flood search report should be obtained from the
local government to confirm the extent that is within the Flooding and inundation area. The flood search report will be
determinative.
(h)
A Dual occupancy (auxiliary unit) or Dwelling house located in an area identified on
Landslide hazard and steep slope area overlay map–OM–08.00 is designed and located
to:
(i)
protect the safety of people and premises from risk of landslide, taking into account
the risks associated with the natural physical process of land movement and
erosion;
(ii)
protect and enhance the visual amenity of adjoining premises, the streetscape and
the locality;
Editor's note––Where a lot is affected by a Landslide hazard and steep slope area identified on Landslide hazard and steep
slope area overlay map–OM–08.00, a certificate can be obtained from the local government to confirm the extent that is within
the Landslide hazard and steep slope area. The certificate will be determinative.
(i)
A Dual occupancy (auxiliary unit) or Dwelling house located in an area identified on
Regional infrastructure corridors and substations overlay map–OM–09.00:
(i)
protects the health and safety of the community;
(ii)
protects regional infrastructure;
(iii) provides access to regional infrastructure at all times;
(iv) provides and maintain buffers to regional infrastructure;
(j)
A Dual occupancy (auxiliary unit) or Dwelling house located within a Water resource
catchment area identified on Water resource catchments area overlay map–OM–12.01 is
designed, constructed and managed to:
(i)
protect the health and safety of a water storage;
(ii)
prevent pollutants from entering a water storage;
(k)
A Dual occupancy (auxiliary unit) or Dwelling house located within the mapped areas
identified on Waterway corridors and wetlands overlay map–OM–13.00 is designed,
constructed and managed to:
(i)
protect and enhance ecosystem processes and the function of a waterway corridor,
wetland, and their riparian areas;
(ii)
protect natural hydrological and geomorphological processes;
(iii) protect and enhance water quality of a waterway and wetland;
(iv) protect and enhance landscape values of a waterway and wetland.
Editor's note––Where a lot is affected by a Waterway corridor and wetland area identified on Waterway corridors and wetlands
overlay map–OM–13.00, a certificate can be obtained from the local government to confirm the extent that is within the
Waterway corridor and wetland area. The certificate will be determinative.
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-13
9.3.1.3
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.3.1.3.1–Dual occupancy and Dwelling house code: self-assessable and assessable
development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Building height
A building has a height in the Environmental
management and conservation zone, Cottage
rural precinct of the Rural residential zone and
Rural zone that:
(a) does not dominate the landscape, bushland,
semi-rural or rural setting for the zone or
precinct;
(b) is responsive to the topography of the area
and site slope.
AO1
A building has a maximum height of 12 metres in
the:
(a) Environmental management and
conservation zone;
(b) Cottage rural precinct of the Rural residential
zone;
(c) Rural zone.
Class 10 buildings
PO2
A class 10a building:
(a) is of a scale and has a built form that is
compatible with the premises and adjoining
premises having regard to:
(i) height, mass and proportion;
(ii) roof form and pitch;
(iii) building materials;
(b) maintains or contributes positively to the
streetscape.
Note––A class 10a building is a non-habitable building being
a private garage, carport, shed, or the like.
AO2
The total maximum gross floor area of a single
class 10a building or multiple class 10a buildings
is:
(a) 40m2 on a lot 400m2 or smaller; or
(b) 60m2 in the following precincts in the Low
density residential zone:
(i) Large suburban precinct;
(ii) Small lot precinct on a lot greater than
400m2;
(iii) Suburban precinct on a lot greater than
400m2;
(iv) Village precinct; or
(c) 110m2 in the following precincts in the Low
density residential zone:
(i) Acreage precinct;
(ii) Small acreage precinct; or
(d) 110m2 in the following precincts in the Rural
residential zone:
(i) Park living precinct;
(ii) Park residential precinct; or
(e) 150m2 in the:
(i) Emerging community zone;
(ii) Environnemental management and
conservation zone;
(iii) following precincts in the Rural
residential zone:
(A) Carbrook precinct;
(B) Cottage rural precinct;
(iv) Rural zone.
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-14
Performance outcomes
Acceptable outcomes
Road boundary clearance
PO3
A Dual occupancy or Dwelling house:
(a) is located to protect existing and planned
movement networks;
(b) has a road boundary clearance compatible
with that of adjoining premises.
AO3
A Dual occupancy or Dwelling house:
(a) is located outside planned widening of a road
and a new road identified in Table 9.3.1.3.2–
Road encroachment maps;
(b) has a minimum road boundary clearance of
10m in the:
(i) Low density residential zone:
(A) Acreage precinct;
(B) Small acreage precinct;
(ii) Rural residential zone:
(A) Carbrook precinct excluding a lot
with a frontage to Mount Cotton
Road or Beenleigh - Redland Bay
Road;
(B) Park living precinct;
(C) Park residential precinct; or
(c) has a minimum road boundary clearance of
20m in the:
(i) Emerging community zone;
(ii) Environmental management and
conservation zone;
(iii) Rural residential zone–Carbrook
precinct with a road frontage to Mount
Cotton Road or Beenleigh–Redland Bay
Road;
(iv) Rural zone; or
(d) has a minimum road boundary clearance of
4m in the:
(i) Low density residential zone – Small lot
precinct;
(ii) Low–medium density residential zone.
Note––For the purposes of the Queensland Development
Code and this acceptable outcome, the nominated road
frontage for the road boundary clearance of a corner lot is the
narrower frontage.
Side and rear boundary clearance
PO4
A Dual occupancy or Dwelling house has a side
and rear boundary clearances that:
(a) is compatible with that of adjoining premises;
(b) allows for the separation of buildings or
structures necessary to ensure impacts on
residential amenity and privacy are
minimised;
(c) provides access to natural light and
ventilation;
(d) provides an area of landscaping;
(e) is consistent with the character for the
relevant zone and precinct.
AO4
A Dual occupancy or Dwelling house has the
following minimum side and rear boundary
clearances:
(a) 3 metres in the Rural residential zone, the
Emerging community zone and the following
precincts in the Low density residential zone:
(i) Acreage;
(ii) Small acreage precinct; or
(b) 10 metres in the:
(i) Environmental management and
conservation zone;
(ii) Rural zone.
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-15
Performance outcomes
Acceptable outcomes
Site cover
PO5
A Dual occupancy or Dwelling house has a site
cover compatible with adjoining premises.
AO5
A Dual occupancy (auxiliary unit) or Dwelling
house has a maximum site cover of:
(a) 40 per cent in the Low density residential
zone–Large suburban precinct;
(b) 35 per cent in the Low density residential
zone–Small acreage precinct;
(c) 20 per cent or 700m2, whichever is greater,
in the Low density residential zone–Acreage
precinct;
(d) in the Rural residential zone:
(i) 20 per cent or 700m2, whichever is
greater, in the Park living precinct or
Park residential precinct; or
(ii) 10 per cent or 700m2 , whichever is
greater, in the Carbrook precinct or
Cottage rural precinct;
(e) 10 per cent or 700m2, whichever is greater,
in the Emerging community zone,
Environmental management and
conservation zone or Rural zone.
Design and siting for a Dwelling house
PO6
A Dwelling house (and a secondary dwelling and
any building or structure ancillary to a Dwelling
house):
(a) that is on a lot that is less than 450m 2 in size
complies with the Performance Criteria
specified in QDC part MP 1.1; or
(b) that is on a lot that is 450m 2 or greater in size
complies with the Performance Criteria
specified in QDC part MP 1.2.
AO6
A Dwelling house (and a secondary dwelling and
any building or structure ancillary to a Dwelling
house):
(a) that is on a lot that is less than 450m 2 in size
complies with the Acceptable Solutions
specified in QDC part MP 1.1; or
(b) that is on a lot that is 450m 2 or greater in size
complies with the Acceptable Solutions
specified in QDC part MP 1.2.
Note––References to QDC parts MP 1.1 and 1.2 for the
purposes of PO6 are to be applied if these provisions applied
to a Secondary dwelling.
Note––Where Table 9.3.1.3.1 AO1, AO3, AO4, AO5, AO8 or
AO9 applies, AO1, AO3, AO4, AO5, AO8 or AO9 prevail over
AO6 to the extent of any inconsistency.
Note––References to QDC parts MP 1.1 and 1.2 for the
purposes of AO6 are to be applied as if these provisions
applied to a Secondary dwelling.
Design and siting for a Dual Occupancy
PO7
A Dual occupancy complies with the
Performance Criteria specified in QDC part MP
1.3.
Note––For the purpose PO7, a reference to “duplex” in QDC
MP1.3 is taken to be “Dual occupancy” as defined by this
planning scheme.
AO7
A Dual occupancy complies with the Acceptable
Solutions specified in QDC part MP 1.3.
Note––For the purpose of AO7, a reference to “duplex” in
QDC MP1.3 is taken to be “Dual occupancy” as defined by
this planning scheme.
Note––Where Table 9.3.1.3.1 AO1, AO3, AO4, AO5, AO8 or
AO9 applies, AO1, AO3, AO4, AO5, AO8 or AO9 prevail over
Note––References to QDC parts MP 1.3 for the purposes of
PO7 are to be applied as if these provisions applied to a Dual AO7 to the extent of any inconsistency.
occupancy.
Note––References to QDC parts MP 1.3 for the purposes of
AO7 are to be applied as if these provisions applied to a Dual
Editor's note––Zone code provisions may prevail over this
occupancy.
performance outcome to the extent of any inconsistency in
accordance with section 1.5(1).
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-16
Performance outcomes
Acceptable outcomes
Editor's note––Zone code provisions may prevail over this
acceptable outcome to the extent of any inconsistency in
accordance with section 1.5(1).
Dual occupancy (auxiliary unit) or secondary dwelling
PO8
Where development is a Dual occupancy
(auxiliary unit) or secondary dwelling, the
subordinate dwelling has a maximum gross floor
area of:
(a) 70m2 if in the residential zone category and
on a lot that is less than 1,000m 2 in size; or
(b) 100m2 otherwise.
AO8
Where development is a Dual occupancy
(auxiliary unit) or secondary dwelling, the
subordinate dwelling has a maximum gross floor
area of:
(a) 70m2 if in the residential zone category and
on a lot that is less than 1,000m 2 in size; or
(b) 100m2 otherwise.
PO9
A Dual occupancy (auxiliary unit) or secondary
dwelling:
(a) has a primary street setback equal to or
greater than the Dwelling house or primary
dwelling;
(b) is located a maximum of 20 metres from the
outermost projection of the Dwelling house or
primary dwelling.
AO9
A Dual occupancy (auxiliary unit) or secondary
dwelling:
(a) has a primary street setback equal to or
greater than the Dwelling house or primary
dwelling;
(b) is located a maximum of 20 metres from the
outermost projection of the Dwelling house or
primary dwelling.
Reverse amenity
PO10
A Dual occupancy (auxiliary unit) or Dwelling
house maintains the operational integrity of the
government supported transport infrastructure
and corridor by mitigating the adverse impacts
of the infrastructure.
AO10
Development, being a Dual occupancy
(auxiliary unit) or Dwelling house, complies with
the noise and vibration criteria for
accommodation activities identified in section
7–Policy for Development on Land Affected by
Environmental Emissions from Transport and
Transport Infrastructure prepared by
Department of Transport and Main Roads
where it:
(a) shares a common boundary with
government supported transport
infrastructure; or
(b) is separated from a government supported
transport infrastructure by only a road,
access way service or utility easement or
other undeveloped land such as a park or
nature reserve; or
(c) is within direct line of sight to government
supported transport infrastructure; or
(d) is within 100 metres of government
supported transport infrastructure.
Dual occupancy (auxiliary unit) or Dwelling house located in the Acid sulfate soils overlay
PO11
AO11
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house in the Potential and actual acid sulfate
house does not involve:
soil area identified on Acid sulfate soils overlay
(a) extracting ground water; or
map–OM–01.00 that involves disturbing soil or
(b) excavating or otherwise removing soil or
sediment at or below 5 metres AHD:
sediment containing acid sulfate soils; or
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-17
Performance outcomes
Acceptable outcomes
(a) avoids disturbing acid sulfate soils; or
(b) is managed to avoid or minimise the release
of:
(i) acid and metal contaminants;
(ii) nutrients that contribute to coastal
algal blooms.
(c) filling that results in acid sulfate soils being
moved below the water table; or
(d) the disturbance of acid sulfate soils;
where the development is:
(a) below 5 metres AHD on Acid sulfate soils
overlay map–OM–01.01 and involves:
(i) excavating or otherwise removing
100m3 or more of soil or sediment; or
(ii) filling of land involving 500m 3 or more
of material with an average depth of
0.5 of a metre or greater; or
(iii) extracting ground water; or
(b) above 5 metres and below 20 metres AHD
on Acid sulfate soils overlay map–OM–
01.01, and involves excavating or otherwise
removing 100m3 or more of soil or sediment
at or below 5 metres AHD.
Editor's note––For assessable development, undertake an
acid sulfate soils investigation conforming to the Guidelines
for Sampling and Analysis of Lowland Acid Sulfate Soils in
Queensland and the Queensland Acid Sulfate Soil
Technical Manual: Laboratory Methods Guidelines. Where
the presence of acid sulfate soils is confirmed, prepare an
acid sulfate soils management plan in accordance with the
Queensland Acid Sulfate Soil Technical Manual: Soil
Management Guidelines.
Dual occupancy (auxiliary unit) or Dwelling house located in the Biodiversity areas overlay
PO12
AO12
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house located in the Primary or Secondary
house in the Primary or Secondary vegetation
management area identified on Biodiversity
vegetation management area identified on
areas overlay map–OM–02.01 is confined
Biodiversity areas overlay map–OM–02.01, that
is not located within a development envelope
within an development envelope area that:
area approved by a development approval:
(a) is approved by Council; or
(a) is located to avoid the need to clear any
(b) is sited and operated with regard to:
native vegetation in the Primary vegetation
(i) the protection of native vegetation;
management area;
(ii) the potential impacts of other overlays
(b) is located to avoid the need to clear any
mapped within the development
native trees or native habitat in the
envelope area
Secondary vegetation management area.
(c) has a size of:
(i) 4,000m2 or less; or
(ii) greater than 4,000m2 where an
environmental offset is provided in
accordance with section 3.1–
Environmental offset standards in
Planning scheme policy 3–
Environmental management, for any
the portion of the envelope that
exceeds 4,000m2.
Note––Compliance with Performance outcome PO12(c)(ii)
is to be demonstrated by an environmental offset report
prepared in accordance with Part 2 of planning scheme
policy 3–Environmental management.
PO13
A Dual occupancy (auxiliary unit) or Dwelling
house in:
(a) a Biodiversity corridor identified on
Biodiversity areas overlay map–OM–02.02
is designed and located to:
(i) provide for habitat links;
(ii) facilitate safe wildlife movement;
AO13
A Dual occupancy (auxiliary unit) or Dwelling
house that is not located within a development
envelope area approved by a development
approval is:
(a) located outside a Biodiversity corridor or
identified on Biodiversity areas overlay
map–OM–02.02;
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-18
Performance outcomes
Acceptable outcomes
(iii) facilitate wildlife refuge;
(iv) enhance habitat values;
(v) rehabilitate degraded areas with native
vegetation; or
(b) a Koala corridor identified on Biodiversity
areas overlay map–OM–02.02 is:
(i) designed and located to protect and
enhance koala habitat;
(ii) designed to minimise adverse light
impacts on native fauna; or
(c) the Locally significant Melaleuca irbyana
buffer area identified on Biodiversity areas
overlay map–OM–02.03 protects the Locally
significant Melaleuca irbyana area identified
on Biodiversity areas overlay map–OM–
02.03 from:
(i) edge effects; or
(d) Development is designed and located to
protect and enhance the landscape values
of:
(i) a ridgeline;
(ii) native vegetation.
(b) located to avoid the need to clear any native
vegetation in a Koala corridor identified on
Biodiversity areas overlay map–OM–02.02;
(c) located outside the Locally significant
Melaleuca irbyana 50 metre buffer area
identified on Biodiversity areas overlay
map–OM–02.03.
Note––Compliance with this performance outcome is to be
demonstrated by a detailed ecological assessment report
prepared in accordance with Part 2 of planning scheme
policy 3–Environmental management.
Dual occupancy (auxiliary unit) or Dwelling house located in the Extractive resources
overlay
PO14
AO14
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house is not located in an Extractive resource
house:
separation area or Transport route separation
(a) does not increase the number of people
area identified on Extractive resources overlay
living in the Extractive resource separation
map–OM–04.01.
area identified on Extractive resources
overlay map–OM–04.01;
(b) in a Transport route separation area
identified on Extractive resources overlay
map–OM–04.01 is compatible with the
transporting of the extractive resource.
Dual occupancy (auxiliary unit) or Dwelling house located in the Flood hazard overlay
PO15
AO15
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house located in an area identified on Flood
house:
Hazard overlay map–OM–05.00:
(a) ensures a building floor level of a habitable
room has adequate allowance for the
(a) has a finished habitable floor level a
minimum of 500mm above the defined flood
hydraulic gradient above the main floodway;
event;
(b) must not increase the level of risk of injury
to life or risk damage to property;
(b) does not result in:
(c) does not add to the emergency
(i) an increase in the number of people at
management or evacuation burden during
risk from flooding up to and including
and after a flood event.
the defined flood event; or
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-19
Performance outcomes
Acceptable outcomes
(ii)
an increase in the number of people
that need evacuation up to and
including the defined flood event.
Dual occupancy (auxiliary unit) or Dwelling house located in the Landslide hazard and steep
slope area overlay
PO16
AO16
A Dual occupancy (auxiliary unit) or Dwelling
If a Dual occupancy (auxiliary unit) or Dwelling
house is not located within a development
house is designed:
envelope area approved by a development
(a) to be responsive to the topography of the
approval and is in a location:
premises;
(a) identified as “Historical landslide areas” on
(b) to be responsive to the visual amenity of
Landslide hazard and steep slope area
adjoining premises, the streetscape and the
overlay map–OM–08.01; or
locality;
(b) where the gradient is equal to or greater
(c) so that the undercroft of a building or is
than 12 percent and the development is
screened when viewed from adjoining
identified on the Landslide hazard and
premises or a road.
steep slope area overlay map—OM08.01
Note––’Compliance with this performance outcome is to be
as:
demonstrated by certification from a Registered
Professional Engineer of Queensland specialising in
(i) “Equal to or greater than 12 percent
geotechnical engineering that the footings, foundations,
slope hazard areas”; or
retaining walls and any other structure is safe and designed
(ii) “12 percent slope investigation areas”;
to prevent landslide.
or
(c) where the gradient is equal to or greater
than 15 percent and the development is
identified on the Landslide hazard and
steep slope area overlay map–OM–08.01
as “Equal to or greater than 15 percent
slope hazard areas” the:
(i) development is carried out in
accordance with a site–specific
engineering report that includes a
certification by a Registered
Professional Engineer of Queensland
with expertise in geotechnical
engineering;
(ii) development does not involve cut and
fill;
(iii) undercroft of the building or structure
has:
(A) skirting or landscape screening to
the full height of the undercroft;
(B) a maximum height at the perimeter
of the building or structure of 3
metres.
Dual occupancy (auxiliary unit) or Dwelling house located in the Regional infrastructure
corridors and substations overlay
PO17
AO17
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house located in the Regional infrastructure and house that is not within a development
buffers identified on Regional infrastructure
envelope area approved by a development
corridors and substations overlay map–OM–
approval located outside the Regional
infrastructure and buffers identified on Regional
09.00:
infrastructure corridors and substations overlay
map–OM–09.00.
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-20
Performance outcomes
Acceptable outcomes
(a) prevents an unacceptable health or safety
risk to the community;
(b) takes into account the impacts of “sag” and
“swing” of 110kv and 275kv powerlines;
(c) protects the operation of water and
petroleum pipelines;
(d) ensures access is provided to the
infrastructure provider at all times for:
(i) 110kv and 275kv powerlines;
(ii) substations;
(iii) wastewater facilities.
Dual occupancy (auxiliary unit) or Dwelling house located in the Water resource
catchments overlay
PO18
AO18
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house in the Water resource catchment areas
house:
identified on Water resource catchments
(a) that is not within a development envelope
overlay map–OM–12.01 is undertaken in a
area approved by a development approval
manner which contributes to maintaining the
is located outside the Water resource
water quality in the water resource catchment
catchment area, identified on Water
areas.
resource catchments area overlay map–
OM–12.01;
(b) is connected to reticulated sewerage; or
(c) is connected to an on-site waste water
treatment or effluent disposal system that
complies with Element 1 of the Seqwater
Development Guidelines – Development
Guidelines for Water Quality Management
in Drinking Water Catchments
Dual occupancy (auxiliary unit) or Dwelling house located in the Waterway corridors and
wetlands overlay
PO19
AO19
A Dual occupancy (auxiliary unit) or Dwelling
A Dual occupancy (auxiliary unit) or Dwelling
house located inside an area mapped on
house that is not within a development
Waterway corridors and wetlands overlay map– envelope area approved by a development
OM–13.00 protects ecosystem processes,
approval is located outside the mapped area
water quality, function, scenic amenity and
identified on Waterway corridors and wetlands
landscape values.
overlay map–OM–13.00.
Table 9.3.1.3.2—Road encroachment maps
Column 1
Column 2
Column 3
Column 4
Project no.
Map name
Drawing no.
Road section
70–144
Loganlea Road (Nujooloo Road
to Kingston Road)
5–7 of 9 plans
Loganlea Road between
Armstrong Road ramp and
Queens Road
Note––Table 9.3.1.3.2—Road encroachment maps identifies in Column 1 the project number, Column 2 the map name, Column
3 the number of encroachment maps prepared for the project (Column 1) and Column 4 the road section.
Disclaimer: Property boundary data for these drawings have been sourced from the Digital Cadastral Database supplied to
Council by Department of Natural Resources and Mines (DNRM). Final horizontal/vertical alignments and any land
requirements for roads are subject to prior survey, detailed road design and consultation with land owners. Planning layouts are
constantly updated. Ensure the latest drawing version is used.
Part 9 Development codes—9.3.1 Dual occupancy and Dwelling house code
Logan Planning Scheme 2015 version 1.1
P9-21
9.3.2
Home based business code
9.3.2.1
Application
(1)
(2)
This code applies to:
(a)
self-assessable and code assessable material change of use for a Home based business
for which the Home based business code is identified in the assessment criteria column
in a table of assessment in section 5.5–Levels of assessment-Material change of use in
Part 5–Tables of assessment;
(b)
material change of use for a Home based business made impact assessable in a table of
assessment in section 5.5-Levels of assessment-Material change of use or Section 5.9–
Levels of assessment-Local plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.2.2
(1)
(2)
Purpose
The purpose of the code is to allow for the operation of small scale businesses:
(a)
in association with a dwelling;
(b)
where compatible with the intended character of the zone and precinct.
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.3.2.3
A Home based business:
(i)
is of a scale compatible with the surrounding area;
(ii)
is compatible with the intended amenity and character of the zone;
(iii) protects the health and safety of people and premises.
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.3.2.3.1–Home based business code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Scale and amenity
AO1
A Home based business:
A Home based business is limited to a business
(a) is of a scale compatible with the dwelling activity that would otherwise be classified as:
(a) where conducted entirely within a dwelling or
and the streetscape;
ancillary building:
(b) is visually compatible with the
streetscape.
(i) Health care services; or
(ii) Office; or
(iii) Shop, limited to the provision of personal
services; or
(iv) Short-term accommodation being a bed and
breakfast or farm stay; or
(b) Outdoor sport and recreation (other than
equestrian tutelage), limited to outdoor sporting
tutelage in an existing facility; or
(c) Outdoor sport and recreation, limited to
equestrian tutelage that has a boundary
clearance of a minimum of 30 metres from the
boundary of an adjoining lot.
Part 9 Development codes—9.3.2 Home based business code
Logan Planning Scheme 2015 version 1.1
P9-22
Performance outcomes
Acceptable outcomes
PO2
A Home based business is compatible with
the intended character of the zone and
precinct.
AO2
A Home based business:
(a) does not include any:
(i) use involving hiring out materials, goods,
appliances or vehicles stored on-premises;
or
(ii) repair or maintenance of a motor vehicle,
an Industry activity or an environmentally
relevant activity;
(b) being for guest accommodation, complies with
the following:
(i) the maximum number of bedrooms used to
accommodate guests does not exceed
three bedrooms;
(ii) meals are not served for gain to other than
paying guests of the use.
AO3
A Home based business:
(a) does not involve any of the following:
(i) more than one non-resident employee or
contractor in the Low density residential
zone (other than the Acreage precinct),
Low-medium density residential zone and
Medium density residential zone; or
(ii) more than two non-resident employees or
contractors in the Low density residential
zone–Acreage precinct and all other zones;
or
(iii) customer visitation outside of the hours of
7am to 6pm Monday to Saturday other than
for guest accommodation; or
(iv) loading or unloading of a vehicle outside of
the hours of 7am to 6pm Monday to
Saturday; or
(v) more than three non–resident motor
vehicles being parked at one time for a
Home based business that is guest
accommodation; or
(vi) more than two non-resident motor vehicles
being parked at one time for a Home based
business that is not guest accommodation;
or
(vii) the use or visitation by a vehicle larger than
a small rigid vehicle; or
(viii) the generation of more than 16 vehicle trips
per day; or
(ix) the display of goods that are visible from a
road frontage or an adjoining premises; or
(x) more than one advertising device; or
(xi) an advertising device with more than one
side; or
(xii) an advertising device that is larger than
0.5m2 in area; or
PO3
A Home based business does not
adversely affect the amenity of the area
having regard to:
(a) number of non-resident employees or
contractors;
(b) customer visitation;
(c) loading and unloading of vehicles;
(d) customer parking;
(e) impact of vehicles;
(f) visual amenity of a streetscape;
(g) noise emissions;
(h) outdoor lighting;
(i) for equestrian tutelage:
(i) boundary clearances;
(ii) dust.
Part 9 Development codes—9.3.2 Home based business code
Logan Planning Scheme 2015 version 1.1
P9-23
Performance outcomes
Acceptable outcomes
(xiii) an illuminated, moving, flashing or rotating
advertising device; or
(xiv) noise emissions at the boundary of the
premises that exceed those specified with
Table 9.3.2.3.2—Noise levels;
(b) where for outdoor sporting tutelage or equestrian
tutelage, does not involve the use of outdoor
lighting;
(c) where for equestrian tutelage:
(i) any enclosure or training area has a
boundary clearance of a minimum of 30
metres from an adjoining lot boundary;
(ii) any training area is surfaced with a material
that limits dust generation (such as coarse
sand or chip sawdust mix).
Health and safety
PO4
A Home based business does not adversely
affect the health and safety of persons
having regard to:
(a) regulated waste; or
(b) flammable or combustible materials.
AO4
A Home based business does not involve:
(a) regulated wastes as defined by the Environmental
Protection Regulation 2008; or
(b) flammable or combustible liquids as defined by
AS1940-2004–The storage and handling of
flammable and combustible liquids.
Table 9.3.2.3.2—Noise levels
Period
Noise level at the boundary of the premises
7am–7pm
Background noise level plus 5dB(A).
7pm–7am
Not detectable at the boundary of the premises.
Note––Measured as the adjusted maximum sound pressure level as defined in the Noise Measurement Manual
(Environmental Protection Agency, 2000).
Part 9 Development codes—9.3.2 Home based business code
Logan Planning Scheme 2015 version 1.1
P9-24
9.3.3
Multiple dwelling, Rooming accommodation and Short-term
accommodation code
9.3.3.1
Application
(1)
(2)
This code applies to:
(a)
code assessable material change of use for a Multiple dwelling, Rooming accommodation
or Short-term accommodation for which the Multiple dwelling, Rooming accommodation
and Short-term accommodation code is identified in the assessment criteria column in a
table of assessment in section 5.5–Levels of assessment-Material change of use in Part
5–Tables of assessment;
(b)
material change of use for a Multiple dwelling, Rooming accommodation or Short-term
accommodation made impact assessable in a table of assessment in section 5.5–Levels
of assessment-Material change of use or section 5.9–Levels of assessment-Local plans
in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.3.2
Purpose
(1)
The purpose of the code is to provide a choice and diversity of housing types that are adaptable
and provides amenity to residents.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
A Multiple dwelling, Rooming accommodation or Short-term accommodation:
(i)
provides a choice and diversity of housing types to cater for different households;
(ii)
provides private and communal open space that is adequate and useable to
service the needs of residents;
(iii) addresses visual privacy and amenity through appropriate screening.
(b)
A Multiple dwelling exceeding 20 dwellings provides on-site management.
9.3.3.3
Criteria for assessment
Part A–Criteria for assessable development
Table 9.3.3.3.1–Multiple dwelling, Rooming accommodation and Short-term accommodation
code: assessable development
Performance outcomes
Acceptable outcomes
For assessable development
Housing diversity
AO1
A Multiple dwelling caters for a mix of household A Multiple dwelling comprising more than 20
sizes having regard to local demographics and
dwellings provides that 30 percent of dwellings
have a different number of bedrooms than other
existing housing supply.
dwellings.
Amenity
PO2
A Multiple dwelling exceeding 20 dwellings
provides on-site management.
AO2
A Multiple dwelling exceeding 20 dwellings has
an on-site manager.
Part 9 Development codes—9.3.3 Multiple dwelling, Rooming accommodation and Short-term accommodation
code
Logan Planning Scheme 2015 version 1.1
P9-25
Performance outcomes
Acceptable outcomes
Built form
PO3
Building layout, location and design of windows
or screen devices minimises adverse privacy
impacts on dwellings.
PO4
Screening and partial enclosure of balconies is
provided to address visual privacy and amenity
of occupants of the dwelling and neighbouring
dwellings.
Private open space
PO5
A Multiple dwelling provides private open space
for each dwelling that:
(a) is well-proportioned and functional;
(b) promotes outdoor living as an extension of
the dwelling.
AO3
Where a building is located within two metres at
ground level or 9 metres above ground level of a
habitable room, window or private open space,
habitable rooms have:
(a) an offset from a habitable room or private
open space to limit overlooking as shown in
Figure 9.3.3.3.1–Window offset; or
(b) sill heights of a minimum 1500mm above
floor levels; or
(c) fixed obscure glazing in any part of the
window below 1500mm above floor level; or
(d) fixed external screens; or
(e) in the case of screening for ground floor,
fencing to a minimum of 1.8 metres above
ground level.
AO4.1
Development provides screening of utilities and
clothes drying racks.
AO4.2
Development provides privacy screening at a
maximum of:
(a) 60 percent of the total individual balcony
face area, where fronting a street;
(b) if west-facing, to a maximum of 100 percent
of the total individual balcony face area;
(c) 100 percent of the total individual balcony
face area if a secondary balcony not
fronting a street, and used for utilities or
drying area.
AO5
A Multiple dwelling has a private open space
area:
(a) for a townhouse, that:
(i) complies with Table 9.3.3.3.2—Private
and communal open space;
(ii) has a minimum dimension of 5 metres;
(iii) is directly accessible from the main
living area;
(iv) has a gradient less than five percent;
or
(b) for an apartment, that:
(i) complies with Table 9.3.3.3.2—Private
and communal open space;
(ii) has a minimum dimension of 2.5
metres;
(iii) is directly accessible from the main
living area;
(iv) has a gradient less than five percent.
Part 9 Development codes—9.3.3 Multiple dwelling, Rooming accommodation and Short-term accommodation
code
Logan Planning Scheme 2015 version 1.1
P9-26
Performance outcomes
Acceptable outcomes
Communal open space
PO6
A Multiple dwelling provides adequate and
useable communal open space for each dwelling
to meet the needs of the residents having regard
to the:
(a) location and accessibility of a park within a
walkable catchment;
(b) area of a park available for passive and
active recreation.
AO6
A Multiple dwelling has a communal open space
area:
(a) for a townhouse, that:
(i) complies with Table 9.3.3.3.2—Private
and communal open space:
(ii) has a minimum dimension of 7.5
metres;
(iii) has a gradient less than five percent; or
(b) for an apartment, that:
(i) complies with Table 9.3.3.3.2—Private
and communal open space;
(ii) has a minimum dimension of 7.5
metres;
(iii) has a gradient less than five percent.
PO7
AO7
A Multiple dwelling, Rooming accommodation or No acceptable outcome provided.
Short-term accommodation provides communal
open space and facilities that are located and
designed to be:
(a) safe and attractive;
(b) easily accessible;
(c) clearly defined;
(d) centrally located;
(e) a combination of passive and active
recreation;
(f) adequate and useable and designed for
climatic comfort;
(g) connected to a foot path.
Table 9.3.3.3.2—Private and communal open space
Use
Private open space
Communal open space
Multiple dwelling being a
townhouse
A minimum of 25m2 courtyard
for each dwelling where
communal open space is
provided
A minimum of 10m 2 for each
dwelling where private open
space is less than 35m 2 for
each dwelling
A minimum of 35m2 courtyard
for each dwelling where no
communal open space is
provided
Multiple dwelling being an
apartment
A minimum of 25m2 for each
dwelling at ground floor.
A minimum of 20 percent of the
site area
A minimum of 15m2 balcony for
each dwelling above ground
floor.
Rooming accommodation or
Short-term accommodation
Not applicable
A minimum of 10 percent of the
site area
Part 9 Development codes—9.3.3 Multiple dwelling, Rooming accommodation and Short-term accommodation
code
Logan Planning Scheme 2015 version 1.1
P9-27
Figure 9.3.3.3.1–Window offset
Part 9 Development codes—9.3.3 Multiple dwelling, Rooming accommodation and Short-term accommodation
code
Logan Planning Scheme 2015 version 1.1
P9-28
9.3.4
Relocatable home park, Residential care facility and Retirement facility
code
9.3.4.1
Application
(1)
(2)
This code applies to:
(a)
code assessable material change of use for a Relocatable home park, Residential care
facility or a Retirement facility for which the Relocatable home park, Residential care
facility and Retirement facility code is identified in the assessment criteria column in a
table of assessment in section 5.5–Levels of assessment-Material change of use in Part
5–Tables of assessment;
(b)
material change of use for a Relocatable home park, Residential care facility or a
Retirement facility made impact assessable in a table of assessment in section 5.5–
Levels of assessment-Material change of use or section 5.9–Levels of assessment–Local
plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.4.2
Purpose
(1)
The purpose of the code is to provide an attractive and comfortable environment for residents
with a range of community facilities.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.3.4.3
A Relocatable home park, Residential care facility, or a Retirement facility is:
(i)
designed to provide accommodation in a safe, accessible and attractive residential
environment;
(ii)
designed to provide a range of community and recreation facilities;
(iii) located to have convenient access to shops, public transport and community
activities.
Criteria for assessment
Part A–Criteria for assessable development
Table 9.3.4.3.1–Relocatable home park, Residential care facility and Retirement facility code:
assessable development
Performance outcomes
Acceptable outcomes
For assessable development
Layout
AO1
A Relocatable home park, Residential care
No acceptable outcome provided.
facility or Retirement facility provides:
(a) a safe and convenient movement network;
(b) open space and landscaping;
(c) vehicle access, parking, servicing and
manoeuvring areas;
(d) amenities and facilities, including storage;
(e) an on-site manager’s residence, if a
Relocatable home park or Retirement facility.
Part 9 Development codes—9.3.4 Relocatable home park, Residential care facility and Retirement facility code
Logan Planning Scheme 2015 version 1.1
P9-29
Performance outcomes
Acceptable outcomes
PO2
A Relocatable home park or Retirement facility
provides that each dwelling is easily identifiable
from an accessway or a road.
AO2
A Relocatable home park or Retirement facility
provides that each dwelling has property
identification numbers that are clearly identifiable
from an accessway or a road.
PO3
AO3
A Relocatable home park provides that each
dwelling has a site with a minimum area of
200m2.
A Relocatable home park provides that a
dwelling has a site of sufficient size and
dimension to accommodate a dwelling and
associated facilities including car parking and
private open space.
Boundary clearance
PO4
A Relocatable home park, Residential care
facility, or Retirement facility provides boundary
clearances that:
(a) allow for the separation of buildings or
structures to ensure the impacts on
residential amenity and privacy for the
occupants of the dwelling and neighbouring
dwellings are minimised;
(b) provide access to natural light and
ventilation;
(c) are consistent with the surrounding
character.
AO4
Development has minimum boundary clearances
that comply with Table 9.3.4.3.1–Relocatable
home park, Residential care facility and
Retirement facility code: assessable
development.
Private open space
PO5
A Relocatable home park or Retirement facility
includes useable private open space to meet the
needs of the residents.
AO5
A Relocatable home park or Retirement facility
provides that each dwelling has private open
space with:
(a) direct access from the principal living area of
each dwelling;
(b) a minimum dimension of three metres.
Communal open space and facilities
PO6
A Relocatable home park, Residential care
facility or Retirement facility provides communal
outdoor open spaces and indoor facilities that
are located and designed to be:
(a) safe and attractive;
(b) easily accessible;
(c) clearly defined and illuminated for night time
use;
(d) centrally located;
(e) a combination of passive and active
recreation facilities.
AO6
No acceptable outcome provided.
Part 9 Development codes—9.3.4 Relocatable home park, Residential care facility and Retirement facility code
Logan Planning Scheme 2015 version 1.1
P9-30
Performance outcomes
Acceptable outcomes
PO7
A Relocatable home park, Residential care
facility or Retirement facility meets the need of
the residents by providing:
(a) outdoor communal open space;
(b) indoor communal facilities.
AO7
A Relocatable home park, Residential care
facility or Retirement facility has:
(a) an outdoor communal open space area being
a minimum 20 percent of the site area with:
(i) a minimum dimension of 15 metres;
(ii) a gradient not exceeding five percent;
(b) an indoor communal facilities area:
(i) of a minimum 10m 2 for each dwelling;
(ii) with a minimum dimension of 5 metres.
Access
PO8
A Relocatable home park, Residential care
facility, or Retirement facility:
(a) provides a bus service or is located within
easy walking distance to public transport;
(b) is located within easy walking distance to a
Shopping centre or provides an on-site shop.
AO8.1
A Relocatable home park or Retirement facility:
(a) has a private bus service; or
(b) is located within 400 metres of a bus service.
AO8.2
A Relocatable home park or Retirement facility:
(a) is located within 400 metres of a Shopping
centre; or
(b) has a kiosk on the premises.
Table 9.3.4.3.1–Relocatable home park, Residential care facility and Retirement facility
boundary clearance provisions
Boundary clearances
Land use
Building
type
Front
boundary
Side boundary
Rear
boundary
Relocatable
home park
Dwelling
6 metres
(a) where the height of that part is
4.5m or less–1.5m; and
(b) where the height of that part is
greater than 4.5m but not more
than 7.5m–2m; and
(c) where the height is greater than
7.5m–2m plus 0.5m for every 3m
or part exceeding 7.5m.
6 metres
Residential care
facility;
Retirement
facility
Dwelling
6 metres
(a) where the height of that part is
4.5m or less -1.5m; and
(b) where the height of that part is
greater than 4.5m but not more
than 7.5m - 2m; and
(c) where the height is greater than
7.5m - 2m plus 0.5m for every
3m or part exceeding 7.5m.
6 metres
Other
building
6 metres
10 metres
10 metres
Editor’s note – Where these boundary clearances differ from the underlying zone code, the zone code prevails to the extent of
the inconsistency.
Part 9 Development codes—9.3.4 Relocatable home park, Residential care facility and Retirement facility code
Logan Planning Scheme 2015 version 1.1
P9-31
9.3.5
Roadside stall code
9.3.5.1
Application
(1)
(2)
This code applies to:
(a)
self-assessable and code assessable material change of use for a Roadside stall for
which the Roadside stall code is identified in the assessment criteria column in a table of
assessment in section 5.5–Levels of assessment-Material change of use in Part 5–
Tables of assessment;
(b)
material change of use for a Roadside stall made impact assessable in a table of
assessment in section 5.5–Levels of assessment-Material change of use or section 5.9–
Levels of assessment–Local plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.5.2
Purpose
(1)
The purpose of the Roadside stall code is to manage the impacts of development.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.3.5.3
A Roadside stall:
(i)
is located to protect the amenity of the surrounding area;
(ii)
is of a scale and form compatible with the surrounding area;
(iii) does not adversely affect the safe function and operation of the movement
network.
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.3.5.3.1–Roadside stall code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Boundary clearance
A Roadside stall on a lot has a boundary
clearances that:
(a) provides for convenience of use;
(b) protects the amenity of adjoining premises.
AO1
A roadside stall has a:
(a) maximum road boundary clearance of 10
metres;
(b) minimum side boundary clearances of 10
metres.
Use, scale and location
PO2
A Roadside stall:
(a) sells produce grown on the premises;
(b) is small-scale;
(c) does not adversely affect the movement
network.
Part 9 Development codes—9.3.5 Roadside stall code
Logan Planning Scheme 2015 version 1.1
AO2
A Roadside stall:
(a) sells only produce grown on the premises;
(b) has a maximum 25m 2 gross floor area;
(c) is not located:
(i) on a State-controlled road; or
(ii) within 100 metres of an intersection.
P9-32
9.3.6
Sales office code
9.3.6.1
Application
(1)
(2)
This code applies to:
(a)
self-assessable and code assessable material change of use for a Sales office for which
the Sales office code is identified in the assessment criteria column in a table of
assessment in section 5.5–Levels of assessment-Material change of use in Part 5–
Tables of assessment;
(b)
material change of use for a Sales office made impact assessable in a table of
assessment in section 5.5–Levels of assessment-Material change of use or section 5.9–
Levels of assessment–Local plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.6.2
(1)
(2)
Purpose
The purpose of the code is to:
(a)
protect the amenity of the surrounding area;
(b)
limit the duration of operation of a Sales office.
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.3.6.3
A Sales office is:
(i)
located and designed to maintain the amenity of adjoining premises;
(ii)
established on a temporary basis commensurate with the completion of sales of
the development being promoted.
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.3.6.3.1–Sales office code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Amenity
A Sales office provides that the number of
employees or contractors does not adversely
affect the amenity of the area.
PO2
A Sales office has operating hours that are
compatible with the nature and type of use on
adjoining premises.
Duration of use
PO3
A Sales office operates for a limited duration
commensurate with the completion of sales of
the development being promoted.
Part 9 Development codes—9.3.6 Sales office code
Logan Planning Scheme 2015 version 1.1
AO1
A Sales office has a maximum of two employees
or contractors on the premises at any one time.
AO2
A Sales office has operating hours that are
limited to:
(a) 8am to 5pm Monday to Saturday;
(b) 10am to 5pm on Sunday.
AO3
A sales office ceases operation on completion
of sale or transfer of the lots or dwelling units
being promoted.
P9-33
9.3.7
Telecommunications facility code
9.3.7.1
Application
(1)
(2)
This code applies to:
(a)
code assessable material change of use for a Telecommunications facility for which the
Telecommunications facility code is identified in the assessment criteria column in a table
of assessment in section 5.5–Levels of assessment-Material change of use in Part 5–
Tables of assessment;
(b)
material change of use for a Telecommunications facility made impact assessable in a
table of assessment in section 5.5–Levels of assessment-Material change of use or
section 5.9–Levels of assessment–Local plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.3.7.2
Purpose
(1)
The purpose of the code is to protect the amenity of the surrounding area.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.3.7.3
A Telecommunications facility:
(i)
is integrated with the natural and built environment;
(ii)
supports co-location;
(iii) minimises adverse amenity impacts on development in a residential zone category.
Criteria for assessment
Part A–Criteria for assessable development
Table 9.3.7.3.1–Telecommunications facility code: assessable development
Performance outcomes
Acceptable outcomes
For assessable development
Amenity
AO1
A Telecommunications facility is located to
A Telecommunications facility has a minimum
minimise any adverse impacts on the intended
boundary clearance of 150 metres from an
amenity for the zone or precinct and an adjoining adjoining lot in the residential zone category.
residential zone category land.
PO2
A Telecommunications facility is designed to:
(a) integrate with the surrounding natural and
built environment;
(b) not be visually obtrusive.
AO2
No acceptable outcome provided.
Location
PO3
A Telecommunications facility:
(a) is co-located with existing
telecommunications facilities; or
(b) provides for future co-location of
telecommunication facilities.
AO3
No acceptable outcome provided.
Part 9 Development codes—9.3.7 Telecommunications facility code
Logan Planning Scheme 2015 version 1.1
P9-34
9.4
Other development codes
9.4.1
Advertising device code
9.4.1.1
Application
(1)
(2)
This code applies to:
(a)
self-assessable and code assessable operational work–advertising device for which the
Advertising device code is identified in the assessment criteria column in Table 5.8.1–
Operational work in Part 5–Tables of assessment;
(b)
operational work—advertising device made impact assessable in Table 5.8.1–
Operational work in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.1.2
(1)
(2)
Purpose
The purpose of the code is to:
(a)
protect the amenity of the surrounding area;
(b)
maintain the safety of the movement network.
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.4.1.3
An Advertising device is designed and located to:
(i)
protect the visual amenity of the surrounding area;
(ii)
not adversely affect the safe function and operation of the movement network.
Criteria for assessment
Part A—Criteria for self-assessable and assessable development
Table 9.4.1.3.1—Advertising device code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Visual amenity and safety of movement network
AO1.1
An advertising device is designed and located:
An advertising device is designed and located
(a) to be compatible and visually integrate with
to comply with Table 9.4.1.3.2–Standards for
the built form and streetscape;
signs.
(b) to be safe for pedestrians, cyclists and
AO1.2
vehicular traffic;
An advertising device is not animated and does
(c) to not distract motorists so as to cause a
not revolve or flash.
traffic hazard.
AO1.3
An off-premises sign complies with Table
9.4.1.3.3—Maximum face area of off-premises
advertising devices in all zones or precincts.
AO1.4
An on-premises freestanding sign complies with
Table 9.4.1.3.4— Maximum face area for an onpremises freestanding sign.
PO2
AO2.1
An advertising device does not create visual
An advertising device is designed and located
to comply with Table 9.4.1.3.2–Standards for
clutter.
signs.
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-35
Performance outcomes
Acceptable outcomes
AO2.2
No more than two free standing advertising
devices are erected per 100 metre road
frontage of a premises:
(a) where in:
(i) the Centre zone, other than in the
Neighbourhood centre precinct;
(ii) the Low impact industry zone;
(iii) the Medium impact industry zone;
(iv) the Mixed use zone;
(v) the Specialised centre zone;
(b) with a separation distance of at least 60
metres from another freestanding sign on
the same road frontage, or 200 metres if
either sign has an electronic component.
AO2.3
An off-premises sign is not located within 500
metres of another existing or approved offpremises sign, with a maximum of three offpremises signs in the same direction of travel in
any five kilometres in:
(a) the Community facilities zone;
(b) the Emerging community zone;
(c) the Environmental management and
conservation zone;
(d) the Recreation and open space zone;
(e) land in a residential zone category;
(f) the Rural zone;
(g) the Rural residential zone.
AO2.4
An advertising device does not include bunting.
For assessable development only
Off-premises sign
PO3
AO3
The view of a building entrance or an existing
No acceptable outcome provided.
advertising device from a road is not obscured by
a new off-premises sign.
Table 9.4.1.3.2–Standards for signs
Column 1
Column 2
Column 3
Type of advertising
device
Standards
Indicative figure
Above awning sign
(a) has a maximum height of 0.5 metres above the
awning, balcony or veranda;
(b) has a maximum width of 0.3 metres;
(c) does not project beyond the width of the awning,
balcony or veranda or is not greater than 2.5
metres in length, whichever is the lesser;
(d) does not project within 0.45 metres of the vertical
projection of the kerb;
Figure 9.4.1.3.1–
Above awning
sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-36
Column 1
Column 2
Column 3
Type of advertising
device
Standards
Indicative figure
(e) has a minimum clearance from the awning fascia
of 0.3 metres;
(f) is not closer than 0.4 metres from any other above
awning sign or a horizontal projecting wall sign;
(g) there is a maximum of one above awning sign per
tenancy.
Banner sign
(a) is not displayed for more than 30 days per
calendar year;
(b) is static;
(c) there is a maximum of one banner sign per
tenancy.
No figure
Below awning sign
(a) has a maximum height of 0.5 metres below the
awning, balcony or veranda;
(b) has a maximum width of 0.3 metres;
(c) does not project beyond the width of the awning,
balcony or veranda or is not greater than 2.5
metres in length, whichever is the lesser;
(d) does not project within 0.45 metres of the vertical
projection of the kerb;
(e) is not closer than 2.5 metres to any other below
awning sign;
(f) has a minimum clearance above ground level of
2.4 metres;
(g) has nothing suspended from the below awning
sign.
Figure 9.4.1.3.2–
Below awning
sign
Building façade sign
(a) that is painted on, attached to or otherwise
incorporated into a wall of a building does not
project above the wall of the building;
(b) that is painted on, attached to or otherwise
incorporated into a window of a building is limited
to a window on the ground floor of the building;
(c) that is painted on, attached to or otherwise
incorporated into the fascia of a building:
(i) does not project above or below the fascia of
the building;
(ii) has a maximum height of one metre or 60%
of the height of a fascia of the building,
whichever is the lesser;
(iii) has a maximum total face of 25 percent of the
building facade.
Figure 9.4.1.3.3–
Building façade
sign
Directional sign
(a) has a maximum height of 1.2 metres above ground
level;
(b) has a maximum total face area of 1m2.
No figure
Free standing sign
(a) has a maximum height from ground level of:
(i) 12 metres in:
(A) the Centre zone, other than in the
neighbourhood centre precinct;
(B) the Low impact industry zone;
(C) the Medium impact industry zone;
(D) the Mixed use zone;
Figure 9.4.1.3.4–
Free standing
sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-37
Column 1
Column 2
Column 3
Type of advertising
device
Standards
Indicative figure
(E) the Specialised centre zone;
(F) 10.5 metres in Centre zone,
Neighbourhood centre precinct;
(G) five metres in all other zones;
being a pole or pylon sign, has a minimum
clearance above ground level of 2.4 metres where
pedestrian access is to occur under the free
standing sign;
(c) where an on-premises sign, has a maximum width
of four metres;
(d) is not located within:
(i) three metres of a side or rear boundary of
premises in a Centre zone; or
(ii) 10 metres of a side or rear boundary of
premises not in a Centre zone;
(e) has a tenant directory sign where the development
contains more than one tenancy.
Horizontal projecting
wall sign
(a) does not project within 0.45 metres of the vertical
projection of the kerb;
(b) has a maximum height above ground level of three
metres;
(c) has a minimum clearance above ground level of
2.4 metres;
(d) there is a maximum of one horizontal projecting
wall-sign per tenancy.
Figure 9.4.1.3.5–
Horizontal
projecting wall
sign
Roadside stall sign
(a) has a maximum of two advertising devices
displayed, in the form of a single-sided sign;
(b) has a maximum total face area of 1m2.
No figure
Roof sign
(a) has a maximum height of 0.9 metres;
(b) does not project past the side of a wall of the
building;
(c) if erected on a roof that has a slope of more than
five degrees, does not project above the highest
point of the roof;
(d) there is a maximum of one roof sign per tenancy.
Figure 9.4.1.3.6–
Roof sign
Sales office sign
(a) is located on premises lawfully operating as a
Sales office;
(b) limited to one sign per road frontage;
(c) has a maximum face area of 5m2.
No figure
Vertical projecting
wall sign
(a) has a minimum clearance above the ground level
of 2.4 metres;
(b) does not project above the façade;
(c) does not project horizontally more than 1.2 metres
from the façade;
(d) has a maximum width of 0.3 metres;
(e) has a maximum height of 2.4 metres;
(f) has a minimum distance to a side boundary of 1.2
metres;
(g) is a minimum of 0.6 metres above the roof of any
awning measured from the bottom of the awning;
Figure 9.4.1.3.7–
Vertical
projecting wall
sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-38
Column 1
Column 2
Column 3
Type of advertising
device
Standards
Indicative figure
(h) there is a maximum of one vertical projecting wall
sign per tenancy.
Table 9.4.1.3.3—Maximum face area of off-premises advertising devices in all zones or
precincts
Column 1
Column 2
Zone
Precinct (where
applicable)
Maximum total (cumulative) face area of all
off-premises advertising devises for a
premises, being whichever is the lesser of
column 3 and column 4
Column 3
Column 4
District
1m2 per metre of road
frontage
48m2
Local
0.5m2 per metre of road
frontage
20m2
Neighbourhood
0.25m2 per metre of road
frontage
5m2
Any other land in the
Centre zone
1m2 per metre of road
frontage
48m2
Albert River tourism;
Logan River tourism;
Highway business;
Old Chatswood Road.
1m2 per metre of road
frontage
48m2
Low impact office
0.5m2 per metre of road
frontage
20m2
Low impact industry
Not applicable
1m2 per metre of road
frontage
48m2
Medium impact
industry
Not applicable
1m2 per metre of road
frontage
48m2
Mixed use
Not applicable
1m2 per metre of road
frontage
48m2
Community facilities
Recreation and open
space
All
0.5m2 per metre of road
frontage where visible from a
road
20m2 where
visible from a
road
Emerging community
Environmental
management and
conservation
Rural
All
0.25m2 per metre of road
frontage
5m2
Low density
residential
Low-medium density
residential
Medium density
residential
Rural residential
All
0m2
Centre
Specialised centre
Editor's note––Off-premises signs are not intended in these
zones.
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-39
Table 9.4.1.3.4— Maximum face area for an on-premises freestanding sign
Type of advertising device
Maximum total face area
Free standing sign where on
premises
10m2 each side in the following zones:
 Centre zone
 Low impact industry zone
 Medium impact industry zone
 Mixed use zone
 Specialised centre zone
5m2 in all other zones
Figure 9.4.1.3.1–Above awning sign
Figure 9.4.1.3.2–Below awning sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-40
Figure 9.4.1.3.3–Building façade sign
Figure 9.4.1.3.4–Free standing sign
Figure 9.4.1.3.5–Horizontal projecting wall sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-41
Figure 9.4.1.3.6–Roof sign
Figure 9.4.1.3.7–Vertical projecting wall sign
Part 9 Development codes—9.4.1 Advertising device code
Logan Planning Scheme 2015 version 1.1
P9-42
9.4.2
Filling and excavation code
9.4.2.1
Application
(1)
This code applies to self-assessable and code assessable operational work—filling or
excavation for which the Filling and excavation code is identified in the assessment criteria
column in Table 5.8.1—Operational work.
(2)
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.2.2
Purpose
(1)
The purpose of the code is to protect premises, people and natural processes from adverse
impacts associated with filling or excavation.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.4.2.3
development protects:
(i)
natural physical processes and ecosystems;
(ii)
existing and planned infrastructure;
(iii) personal health and safety and premises;
(iv) visual amenity.
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.4.2.3.1–Filling and excavation code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Protection of natural processes and ecosystems
The discharge of sediments and pollutants from
filling or excavation does not adversely affect a
waterway or the stormwater network.
AO1
The discharge of sediments and pollutants to a
waterway or stormwater network complies with
part 3.3—Filling and excavation standards in
planning scheme policy 5—Infrastructure.
PO2
Topsoil and spoil stockpiled on the premises do
not adversely affect natural processes and
ecosystems.
AO2
Topsoil and spoil is stockpiled to comply with part
3.3–Filling and excavation standards in planning
scheme policy 5–Infrastructure.
PO3
Filling is carried out using stable, solid and clean
earth, free of organic and putrescible waste,
rubbish and refuse material.
AO3
Filling complies with part 3.3–Filling and
excavation standards in planning scheme policy
5–Infrastructure.
Protection of existing and planned infrastructure
PO4
Filling or excavation works do not adversely
affect infrastructure, including any services.
AO4
Filling or excavation works comply with part 3.3–
Filling and excavation standards in planning
scheme policy 5–Infrastructure.
Part 9 Development codes—9.4.2 Filling and excavation code
Logan Planning Scheme 2015 version 1.1
P9-43
Performance outcomes
Acceptable outcomes
Protection and enhancement of personal health and safety and premises
PO5
Filling or excavation works do not adversely
affect personal health and safety.
AO5
Filling or excavation works comply with part 3.3–
Filling and excavation standards in planning
scheme policy 5–Infrastructure.
Surface water flow
PO6
Surface water drainage does not cause any of
the following:
(a) ponding on any premises; or
(b) a hazard or adversely affect personal health
and safety and premises; or
(c) diversion or concentration of flow from or
onto adjoining premises or infrastructure.
AO6
Surface water drainage complies with part 3.3–
Filling or excavation standards in planning
scheme policy 5–Infrastructure.
Batters
PO7
A batter:
(a) does not adversely affect the natural physical
processes and ecosystems;
(b) protects existing and planned infrastructure;
(c) is safe, stable and easily maintained;
(d) is landscaped to enhance visual amenity.
AO7
A batter is designed and constructed to comply
with the standards specified in section 3.3.6–
Batters and retaining walls in planning scheme
policy 5–Infrastructure.
Retaining walls
PO8
A retaining wall:
(a) is not constructed of timber and are not
located on existing or proposed lot
boundaries, or movement networks;
(b) does not adversely affect the natural physical
processes and ecosystems;
(c) is located to avoid conflict with adjoining
premises;
(d) is located such that existing and planned
infrastructure is not adversely affected;
(e) protects the visual amenity of adjoining
premises or a public open space;
(f) is located within the premises that is being
filled;
(g) is located within the premises that is cut and
is designed to take any surcharge loading
allowable on the uphill lot;
(h) is safe and stable;
(i) enables easy access for maintenance.
AO8
A retaining wall is designed and constructed to
comply with the standards specified in section
3.3.6.2–Retaining walls in planning scheme
policy 5–Infrastructure.
Part 9 Development codes—9.4.2 Filling and excavation code
Logan Planning Scheme 2015 version 1.1
P9-44
Performance outcomes
Acceptable outcomes
Filling of a dam
PO9
The filling of a dam:
(a) does not adversely affect the natural physical
processes and ecosystems;
(b) creates a safe and stable surface;
(c) is integrated into the landscape.
AO9
The filling of a dam complies with part 3.3–Filling
and excavation standards in planning scheme
policy 5–Infrastructure.
Part 9 Development codes—9.4.2 Filling and excavation code
Logan Planning Scheme 2015 version 1.1
P9-45
9.4.3
Infrastructure code
9.4.3.1
Application
(1)
(2)
This code applies to:
(a)
material change of use:
(i)
that is self-assessable or code assessable and for which the Infrastructure code is
identified in the assessment criteria column in a table of assessment in section
5.5–Levels of assessment-Material change of use in Part 5–Tables of
assessment;
(ii)
that is made impact assessable in a table of assessment in section 5.5–Levels of
assessment-Material change of use or Section 5.9–Levels of assessment–Local
plans in Part 5–Tables of assessment;
(b)
reconfiguring a lot:
(i)
that is code assessable and for which the Infrastructure code is identified in the
assessment criteria column in Table 5.6.1–Reconfiguring a lot in Part 5–Tables of
assessment;
(ii)
made impact assessable in Table 5.6.1–Reconfiguring a lot in Part 5–Tables of
assessment;
(c)
operational work that is infrastructure work:
(i)
that is self-assessable or code assessable and for which the Infrastructure code is
identified in the assessment criteria column Table 5.8.1–Operational work in Part
5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.3.2
Purpose
(1)
The purpose of the code is to ensure that infrastructure is provided to service development.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
development protects the existing infrastructure and planned infrastructure networks
being the:
(i)
movement network;
(ii)
park network;
(iii) water network;
(iv) sewerage network;
(v)
stormwater network;
(vi) other networks including electricity, gas and telecommunications;
(vii) land for community facilities network;
(b)
development other than operational work provides infrastructure that is necessary to
service the development, including elements of:
(i)
a safe, efficient and legible road network;
(ii)
a safe, efficient and legible public transport network;
(iii) a safe, efficient and legible cycle network;
(iv) a safe, efficient and legible pedestrian network;
(v)
a safe, efficient and legible parks network;
(vi) a safe and efficient water network;
(vii) a safe and efficient sewerage network;
(viii) a safe and efficient stormwater network;
(ix) safe and efficient other networks including electricity, gas and telecommunications;
(x)
a safe and efficient road lighting network;
(xi) land for a community facilities network;
(c)
development integrates with existing and planned infrastructure networks;
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1
P9-46
(d)
infrastructure is designed and constructed to deliver a standard of service that is efficient
and equitable;
(e)
the cost to the community for the life of the infrastructure is minimised by providing for a
suitable design life, ease of maintenance and ease of replacement;
(f)
infrastructure protects personal health and safety and premises;
(g)
infrastructure protects environmental values.
9.4.3.3
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.4.3.3.1–Infrastructure code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Provision, design, construction and location of infrastructure
AO1
Development is demonstrated to be capable of
Reports, plans and drawings are provided in
accordance with part 2 of planning scheme
being serviced by necessary infrastructure.
policy 5–Infrastructure.
PO2
AO2
Development:
Development:
(a) provides necessary infrastructure to service (a) in a water supply service area connects to
the water network in accordance with the
the development;
SEQ Water Supply and Sewerage Design
(b) provides that the design, construction and
and Construction Code;
location of necessary infrastructure:
(b) not in a water supply service area provides
(i) protects existing and planned
a tank with a minimum storage capacity of
infrastructure networks;
45,000 litres;
(ii) services proposed development;
(c)
in a sewerage supply service area connects
(iii) integrates with existing and planned
to the waste water network in accordance
infrastructure networks;
with the SEQ Water Supply and Sewerage
(iv) delivers a standard of service that is
Design and Construction Code;
efficient and equitable;
(d) not in a sewerage supply service area
(v) minimises the cost to the community
complies with part 1 of the Queensland
for the life of the infrastructure by
Plumbing and Wastewater Code;
providing a suitable design life, ease of
(e)
provides stormwater infrastructure in
maintenance and ease of replacement;
accordance with part 3.6 of planning
(vi) protects personal health, safety and
scheme policy 5–Infrastructure;
premises;
(f) provides a movement network infrastructure
(vii) protects environmental values.
in accordance with part 3.4 of planning
scheme policy 5–Infrastructure;
(g) provides parks in accordance with part 3.12
of planning scheme policy 5–Infrastructure;
(h) provides road lighting in accordance with
part 3.5 of planning scheme policy 5–
Infrastructure;
(i) provides electricity reticulation in
accordance with part 3.8 of planning
scheme policy 5–Infrastructure;
(j) provides gas and telecommunications
reticulation in accordance with part 3.9 of
planning scheme policy 5–Infrastructure.
Editor's note––The delivery of any part of a network
identified in the plans for trunk infrastructure is governed by
Part 4—Priority infrastructure plan.
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1
P9-47
Location of development
PO3
Development is located to protect existing and
planned infrastructure networks.
Fire fighting
PO4
Development in a water service area accessed
by common private title provides:
(a) fire hydrant infrastructure;
(b) unimpeded access for emergency services
vehicles.
Editor's note––The term common private title refers to areas
such as access roads in community title developments or
strata title unit access, which are private and under group or
body corporate control.
PO5
Development not in a water service area
provides sufficient water storage with adequate
pressure, volume and flow to service
development for fire fighting purposes.
AO3
Development is located outside:
(a) planned widening of a road or a new road
identified in Table 7.3.1.1–Road
encroachment maps of planning scheme
policy 5—Infrastructure;
(b) planned public transport network identified
on Figure 3.4.1.3.1—Public transport
network in planning scheme policy 5—
Infrastructure;
(c) a planned cycle network identified on Figure
3.4.1.2.1–Cycle network in planning
scheme policy 5–Infrastructure;
(d) a planned park network identified in PIP
map 09.00 Plan for trunk park infrastructure
in Schedule 3–Priority infrastructure plans
and mapping.
AO4
Development in a water service area accessed
by common private title complies with the
Acceptable outcomes of the SPP code: Fire
services in developments accessed by common
private title in Appendix 1 of the state planning
policy.
AO5
Development:
(a) is connected to a reticulated water supply
scheme that has sufficient flow and
pressure characteristics for fire fighting
purposes at all times with a minimum
pressure and flow of 10 litres per second at
200kPa; or
(b) has an on-site water storage in accordance
with Table 9.4.3.3.2—Water storage for fire
fighting, dedicated or retained for fire
fighting purposes that is made of fire
resistant materials and is:
(i) a separate tank; or
(ii) a reserve section in the bottom part of
the main water supply tankwater tank .
Editor's note––The requirement in AO5 is;
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1

in addition to the requirement for potable water
supply/storage in AO2 in Table 9.4.3.3.2–
Infrastructure code: self-assessable and assessable
development;

reflected in AO5 in Table 8.2.3.3.1–Bushfire hazard
overlay code: self-assessable and assessable
development.
P9-48
Disposal of trade waste
PO6
The disposal of trade waste in a sewerage
supply service area does not adversely affect
the sewerage network.
AO6
The disposal of trade waste in a sewerage
supply service area complies with the sewer
admission standards in section 3.2.6–Sewer
admission standards in planning scheme policy
3–Environmental management.
Roof water drainage and surface water drainage
PO7
AO7
Development provides stormwater infrastructure Development complies with the standards for
for the drainage of the premises so as not to
stormwater infrastructure specified in part 3.6 of
cause any of the following:
planning scheme policy 5–Infrastructure.
(a) ponding of stormwater on the premises;
(b) a hazard to personal health and safety;
(c) damage to premises;
(d) an increased risk of flooding to premises
within the catchment.
Natural flow of surface water
PO8
Development provides that the natural flow of
surface water is:
(a) not altered so as to cause a risk to personal
health and safety or damage to property;
(b) not increased in intensity, velocity or
frequency;
(c) not concentrated onto adjoining premises.
Water sensitive urban design
PO9
Development which provides stormwater
infrastructure incorporates water sensitive urban
design principles having regard to:
(a) protecting existing natural features and
ecological processes;
(b) protecting the natural hydrologic behaviour
of catchments;
(c) protecting the existing natural flow and
water quality regimes of waterways;
(d) protecting water quality of surface and
ground waters;
(e) minimising demand on the water network;
(f) minimising sewage discharges to the natural
environment;
(g) integrating water into the landscape to
enhance visual and ecological values.
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1
AO8
Development complies with the standards for
stormwater infrastructure specified in part 3.6 of
planning scheme policy 5–Infrastructure.
AO9
Development complies with the standards for
stormwater infrastructure specified in part 3.6 of
planning scheme policy 5–Infrastructure.
P9-49
Movement network
PO10
The projected traffic levels for a use do not
adversely affect the planned standards of
service for a road or intersection.
Integrated movement concept report
PO11
Development which generates more than 3,000
vehicle trips per average weekday is designed
to integrate the movement network to minimise
the transportation costs required to service the
use.
AO10
Development does not cause or contribute to
projected traffic levels:
(a) exceeding the maximum vehicle trips per
day in Table 3.4.1.4.2 in planning scheme
policy 5–Infrastructure; or
(b) exceeding the maximum control delays
through intersections in peak periods in
Table 3.4.1.4.3 in planning scheme policy
5—Infrastructure.
AO11
Development which generates more than 3,000
vehicle trips per average weekday provides an
integrated movement concept report which
integrates the planning of the movement
network in accordance with part 2 and 3 of
planning scheme policy 5–Infrastructure.
For assessable development only
Land use and transport integration
PO12
Development within 400 metres of existing or
future public passenger transport facilities
where the total site are is 5000m2 or more:
(a) supports a road hierarchy which facilitates
efficient, safe and accessible bus services
connecting to existing and future public
passenger transport facilities;
(b) enhances connectivity between existing and
future public passenger transport facilities
and other transport modes;
(c) optimises the walkable catchment to
existing and future public passenger
transport facilities;
(d) provides for direct and safe access to and
use of existing or future public passenger
transport facilities.
AO12
No acceptable outcome provided.
Note––SPP code: Land use and transport integration in
Appendix 4 of the state planning policy provides guidance to
achieve this outcome.
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1
P9-50
Table 9.4.3.3.2—Water storage for fire fighting
Column 1
Column 2
Lot size / use type
Water requirement
For each residential lot:
(a) less than 1000m2
2
5,000 litres
(b) between 1000m and less than 1 hectare
10,000 litres
(c) greater than 1 hectare
20,000 litres
Multiple dwelling
5,000 litres per dwelling up to a maximum
of 20,000 litres
A use other than Multiple dwelling
5,000 litres or the prevailing rural fire
brigade standard
Part 9 Development codes—9.4.3 Infrastructure code
Logan Planning Scheme 2015 version 1.1
P9-51
9.4.4
Landscape code
9.4.4.1
Application
(1)
(2)
This code applies to:
(a)
material change of use:
(i)
that is code assessable and for which the Landscape code is identified in the
assessment criteria column in a table of assessment in section 5.5–Levels of
assessment-Material change of use in Part 5–Tables of assessment;
(ii)
that is made impact assessable in a table of assessment in section 5.5–Levels of
assessment-Material change of use or section 5.9–Levels of assessment–Local
plans in Part 5–Tables of assessment;
(b)
reconfiguring a lot:
(i)
that is code assessable and for which the Landscape code is identified in the
assessment criteria column in Table 5.6.1–Reconfiguring a lot in Part 5–Tables of
assessment;
(ii)
made impact assessable in Table 5.6.1–Reconfiguring a lot in Part 5–Tables of
assessment;
(c)
operational work that is landscape work:
(i)
that is self assessable and for which the Landscape Code is identified in the
assessment criteria column Table 5.8.1—Operational work in Part 5–Tables of
assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.4.2
Purpose
(1)
The purpose of the code is to enhance visual amenity of the built and natural environment.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
Landscaping is designed and located to:
(i)
enhance the amenity of premises;
(ii)
enhance streetscapes;
(iii) protect the movement network;
(iv) be responsive to site conditions;
(v)
retain significant on-site vegetation, where practicable;
(vi) protect a building and infrastructure;
(vii) be cost effective to maintain;
(viii) buffer incompatible uses;
(ix) protect personal health and safety;
(x)
rehabilitate degraded areas;
(b)
A degraded area is rehabilitated with endemic species.
Part 9 Development codes—9.4.4 Landscape code
Logan Planning Scheme 2015 version 1.1
P9-52
9.4.4.3
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.4.4.3.1–Landscape code: self-assessable and assessable development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Landscape design
Development provides landscaping that is
designed and located to:
(a) enhance the visual amenity of premises;
(b) provide street trees;
(c) protect the movement network by:
(i) maintaining pedestrian accessibility;
(ii) not obstructing sightlines for
pedestrians, cyclists and motorists;
(iii) being consistent with the function of the
road;
(iv) being of a scale that is in proportion with
the road width;
(d) be responsive to and compatible with soil
conditions, topography and micro climate;
(e) utilise species selection that:
(i) is suitable for the available space and
growing conditions;
(ii) incorporates, where practicable, native
vegetation in public open space and
roads;
(f) protect, where practicable, existing native
trees;
(g) conserve energy and water;
(h) incorporate water sensitive urban design
principles;
(i) prevent pondage and manage overland flow;
(j) act as a buffer to screen adverse visual
impact of development and incompatible
uses;
(k) rehabilitate degraded areas on the premises;
(l) be easily maintained.
AO1
A landscape site analysis and landscape concept
plan demonstrating how landscaping addressing
the elements in PO1 are incorporated into the
development design:
(a) are prepared in accordance with part 2 of
planning scheme policy 5–Infrastructure;
(b) are provided to the local government.
Editor's note––Section 4.2–Guidelines for landscaping in
planning scheme policy 5–Infrastructure sets out
requirements in relation to these elements.
Part 9 Development codes—9.4.4 Landscape code
Logan Planning Scheme 2015 version 1.1
P9-53
9.4.5
Management of emissions and hazardous activities code
9.4.5.1
Application
(1)
This code applies to:
(a)
(2)
self-assessable and code assessable material change of use for an Industry activity,
Major sport, recreation and entertainment facility, Motor sport facility, Outdoor sport and
recreation and Service station for which the Management of emissions and hazardous
activities code is identified in the assessment criteria column in a table of assessment in
section 5.5–Levels of assessment-Material change of use and section 5.9–Levels of
assessment–Local plans in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.5.2
Purpose
(1)
The purpose of the code is to manage impacts of emissions on sensitive land uses and
minimise the health and safety risks on the community from development involving hazardous
materials.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
development is designed to effectively manage adverse impacts and hazards on a
sensitive land use;
(b)
development, involving the storage of hazardous chemicals, ensures that hazardous
chemicals are appropriately stored to reduce the risk of contamination to the
environment;
(c)
a site that is contaminated or poses a health risk is remediated prior to being developed
for an alternative land use.
9.4.5.3
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.4.5.3.1–Management of emissions and hazardous activities code: assessable
development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Air, noise and odour pollution
AO1
A sensitive land use is not exposed to air,
noise and odour emissions from Industry
activities, Major sport, recreation and
entertainment facility, Motor sport facility or
Outdoor sport and recreation that have the
potential to adversely impact on human
health, amenity and wellbeing.
An Industry activity, Major sport, recreation and
entertainment facility, Motor sport facility or Outdoor
sport and recreation is designed, constructed and
operated to ensure that:
(a) the indoor objectives of the Environmental
Protection (Noise) Policy 2008 are met;
(b) the requirements identified in Table 3.2.1.1–Noise
emission standards for the protection of
residential amenity are met;
(c) the requirements identified in Table 3.2.1.2–Noise
emission standards for the protection of general
amenity are met;
(d) the air quality objectives in the Environmental
Protection (Air) Policy 2008 are met;
Part 9 Development codes—9.4.5 Management of emissions and hazardous activities code
Logan Planning Scheme 2015 version 1.1
P9-54
Performance outcomes
Flammable and combustible liquids
PO2
A Service station is designed and
constructed to ensure that on-site
operations:
(a) do not cause environmental harm;
(b) do not result in the release of untreated
pollutants;
(c) prevent the emission of contaminant to
land, surface water or groundwater.
Acceptable outcomes
(e) the requirements identified in Table 3.2.2.1–Air
emission standards are met;
(f) noxious and offensive odours are not experienced
at the boundary of a sensitive land use.
AO2
A Service station:
(a) is designed and constructed to comply with:
(i) AS1940-2004–The storage and handling of
flammable and combustible liquids;
(ii) AS/NZS 1596:2008–The storage and
handling of LP Gas;
(iii) Equipment Level 1 of AS4897-2008–The
design, installation and operation of
underground petroleum storage systems;
(iv) AS4977-2008–Petroleum products –
Pipeline, road tanker compartment and
underground tank identification;
(b) has installed and maintains and operates Stage 1
and Stage 2 Vapour Recovery Systems in
compliance with NSW DECC Standards and Best
Practice Guidelines for Vapour Recovery at Petrol
Service Stations;
(c) is designed and managed to prevent the
discharge of contaminants to the stormwater
system by:
(i) discharging contaminants in the fuel
dispensing area (under canopy) to a blind
sump with a minimum capacity of 10kL;
(ii) discharging contaminants in the general
forecourt (not under canopy) to the
stormwater system via a separator with a
minimum capacity of 10kL;
(iii) discharging contaminants from the
underground storage tank remote fill point to
an on-site holding tank;
(d) has a spill activated cut-off valve installed.
PO3
AO3
Development (other than a Service station)
involving the storing or dispensing of
petroleum, is designed and constructed to
ensure that on-site operations:
(a) do not cause environmental harm;
(b) do not result in the release of untreated
pollutants;
(c) prevent the emission of contaminant to
land, surface water or groundwater.
Development (other than a Service station) involving
the storing or dispensing of petroleum, is designed
and constructed to comply with:
(a) AS1940-2004–The storage and handling of
flammable and combustible liquids;
(b) AS1692-2006–Steel tanks for flammable and
combustible liquids;
(c) AS1657-2013–Fixed platforms, walkways,
stairways and ladders–Design, construction and
installation;
(d) UL 142-1968–Steel Above Ground Tanks for
Flammable and Combustible Liquids;
(e) ULC S601.00–Standard for Shop Fabricated
Steel Aboveground Horizontal Tanks for
Flammable and Combustible Liquids.
Part 9 Development codes—9.4.5 Management of emissions and hazardous activities code
Logan Planning Scheme 2015 version 1.1
P9-55
Performance outcomes
PO4
Development involving the storing or
dispensing of petroleum from underground
tanks ensures that the underground tanks
are decommissioned appropriately.
Hazardous chemicals
PO5
Buildings containing fire-risk hazardous
chemicals are designed to detect the early
stages of a fire situation and notify a
designated person.
PO6
Aboveground storage areas containing
hazardous chemicals and fuels are designed
with spill containment systems.
Acceptable outcomes
AO4
Development involving the storing or dispensing of
petroleum from underground tanks ensures that the
underground tanks are removed in accordance with
AS4976-2008–The removal and disposal of
underground petroleum storage tanks.
AO5
Buildings containing fire-risk hazardous chemicals are
provided with 24 hour monitored fire detection system
for early detection of a fire event.
AO6
Bunded areas for the storage of hazardous chemicals
and fuels are provided:
(a) in a separate enclosed area with an impervious
floor;
(b) of a capacity at least 100 percent of the capacity
of the largest tank or package plus 25 percent of
the combined capacity;
(c) covered by sufficient roofing to prevent the egress
of rainwater entering the bunded area if the
storage area is outside.
Part 9 Development codes—9.4.5 Management of emissions and hazardous activities code
Logan Planning Scheme 2015 version 1.1
P9-56
9.4.6
Reconfiguring a lot code
9.4.6.1
Application
(1)
(2)
This code applies to:
(a)
code assessable reconfiguring a lot for which the Reconfiguring a lot code is identified in
the assessment criteria column in:
(i)
Table 5.6.1–Reconfiguring a lot in Part 5–Tables of assessment; or
(ii)
a table of assessment in section 5.9–Levels of assessment–Local plans in Part 5–
Tables of assessment.
(b)
reconfiguring a lot made impact assessable in:
(i)
Table 5.6.1–Reconfiguring a lot in Part 5–Tables of assessment ; or
(ii)
a table of assessment in section 5.9–Levels of assessment–Local plans in Part 5–
Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.6.2
Purpose
(1)
The purpose of the code is to ensure that new lots are of appropriate size, shape, dimension
and density to accommodate development.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.4.6.3
Reconfiguring a lot results in:
(i)
design outcomes that are consistent with the intended character of the applicable
zone, local plan, precinct, and adjoining road;
(ii)
new lots of appropriate size, shape and dimension;
(iii) an access easement that is safe and does not adversely affect adjoining premises;
(iv) creation of lots that enable the siting of buildings to mitigate potential adverse
impacts from rural activities, Medium impact industry, High impact industry or
Special industry;
(v)
the protection of the lawfulness of an approved Multiple dwelling.
Criteria for assessment
Part A–Criteria for assessable development
Table 9.4.6.3.1–Reconfiguring a lot code: assessable development
Performance outcomes
Acceptable outcomes
For assessable development
Boundary realignment
A boundary realignment results in lots that are
consistent with the size and dimension of lots in
the zone and precinct.
PO2
A boundary realignment ensures a use and its
necessary associated infrastructure are located
on the same lot.
AO1
A boundary realignment complies with the
standards specified in Table 9.4.6.3.2–
Reconfiguring a lot and Table 9.4.6.3.3–
Reconfiguring a lot: local plans.
AO2
A boundary realignment ensures that a building
or structure that is not intended for common use
and sharing by a formal title arrangement is not
located across a boundary or within a setback
required elsewhere in the planning scheme.
Part 9 Development codes—9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-57
Performance outcomes
Acceptable outcomes
Design
PO3
Reconfiguring a lot results in lots of a size,
shape, dimension and density that are consistent
with their intended use and the intended
character of the applicable zone, local plan and
precinct.
AO3
Unless involving an approved Multiple dwelling, a
new lot complies with:
(a) Table 9.4.6.3.2–Reconfiguring a lot ; or
(b) Table 9.4.6.3.3–Reconfiguring a lot: local
plans; or
(c) a preliminary approval for reconfiguring a lot.
PO4
AO4
Reconfiguring a lot is designed to:
No acceptable outcome provided.
(a) protect significant natural features;
(b) protect landscape amenity values;
(c) minimise the amount of excavation and filling.
Note––Planning scheme policy 8–Urban design provides
guidelines on how to achieve this outcome.
PO5
Reconfiguring a lot provides a diverse mix of lot
sizes.
AO5
No acceptable outcome provided.
Note––Planning scheme policy 8–Urban design provides
guidelines on how to achieve this outcome for developments
of 10 or more lots.
PO6
Reconfiguring a lot facilitates a movement
network that:
(a) is permeable;
(b) supports active transport.
AO6
No acceptable outcome provided.
Note––Planning scheme policy 8–Urban design provides
guidelines on how to achieve this outcome.
PO7
Reconfiguring a lot provides that the orientation
of a road and lot facilitates the development of
energy efficient buildings that respond to local
climatic conditions.
AO7
No acceptable outcome provided.
Note––Planning scheme policy 8–Urban design provides
guidelines on how to achieve this outcome.
PO8
The location and orientation of residential lots
enables the siting of buildings to mitigate
potential adverse impacts from rural activities,
Medium impact industry, High impact industry or
Special industry.
Access easement
PO9
An access easement:
(a) is fit for its particular purpose;
(b) has a safe access point;
AO8
A lot for a residential purpose is not created
within the distances stated for any of the
following:
(a) 1500 metres of a Special industry; or
(b) 500 metres of a High impact industry; or
(c) 500 metres of an Intensive animal industry;
or
(d) 300 metres of an Intensive horticulture or
Wholesale nursery or;
(e) 250 metres of a Medium impact industry.
AO9
No acceptable outcome provided.
Part 9 Development codes—9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-58
Performance outcomes
Acceptable outcomes
(c) does not adversely affect adjoining premises
having regard to any of the following:
(i) traffic; or
(ii) accessibility; or
(iii) parking; or
(iv) privacy.
Lots adjoining an urban arterial road
PO10
Reconfiguring a lot is designed to enhance the
visual amenity of an urban arterial road and
avoids creating a streetscape that is likely to be
dominated by fencing ancillary to future land
uses.
AO10
Reconfiguring a lot that results in lots that adjoin
an urban arterial road provides:
(a) a land dedication of a road for public use to
Council between the lot/s adjoining the
urban arterial road and the urban arterial
road that:
(i) is a minimum of 3 metres wide;
(ii) extends for the full length of the lot
boundaries that adjoin the urban
arterial road;
(iii) is landscaped with native, locally
endemic species at a density sufficient
to screen the development from view
from the urban arterial road; or
(b) a constructed road between the lot/s
adjoining an urban arterial road and the
urban arterial road in accordance with a
General planning layout in section 7.2. of
planning scheme policy 5–Infrastructure.
Note––AO10(b) only applies to development identified in a
General planning layout in section 7.2 of planning scheme
policy 5–Infrastructure.
Approved dwellings
PO11
Reconfiguring a lot where material change of
use has been granted for three of more
dwellings does not compromise the lawfulness
and function of the approved use.
AO11
Reconfiguring a lot where material change of
use has been granted for three of more
dwellings:
(a) does not result in a building that straddles a
boundary;
(b) does not compromise the use of a dwelling
as a self-contained residence.
Part 9 Development codes—9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-59
Table 9.4.6.3.2–Reconfiguring a lot
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Minimum
access width
Minimum
area clear
of access
Low density
residential
zone–Small lot
precinct
No minimum.
350m2
10m
6m
12m
3 to 1
A rear lot is not created in this precinct.
Low density
residential
zone–
Suburban
precinct
350m2
500m2
15m
10m
17m
3 to 1
35m
4m for one rear
dwelling and 3m
minimum
pavement width.
600m2
6m for two to
five rear
dwellings and
5.5m minimum
pavement width.
8m for more
than five rear
dwellings and
6m minimum
pavement width.
Low density
residential
zone–Village
precinct
500m2
600m2
18m
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
10m
20m
3 to 1
50m
4m for one rear
dwelling and 3m
minimum
pavement width.
600m2
P9-60
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Minimum
access width
Minimum
area clear
of access
6m for two to
five rear
dwellings and
5.5m minimum
pavement width.
8m for more
than five rear
dwellings and
6m minimum
pavement width.
Low density
residential
zone–Large
suburban
precinct
1000m2
No
minimum.
20m
10m
22m
3 to 1
60m
4m for one rear
dwelling and 3m
minimum
pavement width.
1000m2
6m for 2 to 5
rear dwellings
and 5.5m
minimum
pavement width.
8m for more
than 5 rear
dwellings and
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-61
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Minimum
access width
Minimum
area clear
of access
6m minimum
pavement width.
Low density
residential
zone – Small
acreage
precinct
2000m2
No
minimum
20m
15m
30m
4 to 1
75m
4m for one rear
dwelling and 3m
minimum
pavement width.
2000m2
6m for two to
five rear
dwellings and
5.5m minimum
pavement width.
8m for more
than five rear
dwellings and
6m minimum
pavement width.
Low density
residential
zone–
Acreage
precinct
4000m2
No
minimum
40m
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
20m
40m
4 to 1
A rear lot is not created in this precinct.
P9-62
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Minimum
access width
Minimum
area clear
of access
Low-medium
density
residential
zone–
Townhouse
precinct
600m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Low-medium
density
residential
zone–
Apartment
precinct
800m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Medium
density
residential
zone–Medium
rise precinct
1200m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Medium
density
residential
zone–High
rise precinct
1200m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Centre zone
No minimum
No
minimum
No minimum frontage
No
maximum
A rear lot is not created in this zone.
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-63
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Minimum
access width
Minimum
area clear
of access
Specialised
centre zone
No minimum
No
minimum
No minimum frontage
No
maximum
A rear lot is not created in this zone.
Recreation
and open
space zone
No minimum
No
minimum
No minimum frontage
No
maximum
A rear lot is not created in this zone.
Low impact
industry zone
2000m2
No
minimum
25m
20m
30m
4 to 1
A rear lot is not created in this zone.
The width is
sufficient to
allow the
specified heavy
vehicle to turn
around on the
lot.
Medium
impact
industry zone
2000m2
No
minimum
25m
20m
30m
4 to 1
A rear lot is not created in this zone.
The width is
sufficient to
allow the
specified heavy
vehicle to turn
around on the
lot.
Community
facilities zone
No minimum.
No
minimum
No minimum frontage
No
maximum
A rear lot is not created in this zone.
Emerging
community
zone
20 hectares
No
minimum
No minimum frontage
No
maximum
No
maximum
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
20 hectares
P9-64
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Maximum
access
length
Environmental
management
and
conservation
zone
100 hectares
No
minimum
No minimum frontage
No
maximum
No
maximum
Mixed use
zone
2000m2
No
minimum
25m
4 to 1
150m
Rural zone
100 hectares
No
minimum
No minimum frontage.
No
maximum
No
maximum
Rural
residential
zone–Park
residential
precinct
4000m2
5000m2
40m
3 to 1
150m
Rural
residential
zone–Park
living precinct
100 hectares
No
minimum
No minimum frontage
No
maximum
No
maximum
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
20m
20m
30m
40m
Minimum
access width
Minimum
area clear
of access
100 hectares
10m
4000m2
The width is
sufficient to
allow the
specified heavy
vehicle to turn
around on the
lot.
100 hectares
10m
4000m2
100 hectares
P9-65
Column 1
Column 2
Column
3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum lot
size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Rural
residential
zone–Cottage
rural precinct
and Carbrook
precinct
(a) 20
hectares in
the urban
footprint;
(b) 100
hectares in
the
regional
landscape
and rural
production
area.
No
minimum
Cul-desac lot
Corner
lot
No minimum frontage
Maximum
access
length
No
maximum
No
maximum
Minimum
access width
Minimum
area clear
of access
100 hectares
Editor's note–– 1 Average lot size is calculated as the site area divided by the proposed number of lots.
Note––’The Minimum access width applies when one rear lot is created.
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-66
Table 9.4.6.3.3–Reconfiguring a lot: local plans
Column 1
Column 2
Column 3
Column 4
Column 5
Column 6
Column 7
Zone and/or
precinct
Minimum
lot size
Minimum
average
lot size1
Minimum frontage
Maximum
depth to
width ratio
Rear lot
Qualifications
Normal
Cul-desac lot
Corner
lot
Minimum
access
length
Minimum
access width
Minimum
area clear
of access
Loganlea Local plan
Residential
edge precinct
600m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Residential
frame precinct
or Residential
core precinct
800m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Low medium
precinct or
Mixed use
precinct
1200m2
No
minimum
20m
No
minimum
30m
3 to 1
A rear lot is not created in this precinct.
Editor's note––1 Average lot size is calculated as the site area divided by the proposed number of lots.
Note––The Minimum access width applies when one rear lot is created
Part 9 Development codes - 9.4.6 Reconfiguring a lot code
Logan Planning Scheme 2015 version 1.1
P9-67
9.4.7
Servicing, access and parking code
9.4.7.1
Application
(1)
(2)
This code applies to:
(a)
material change of use:
(i)
that is self-assessable or code assessable and for which the Servicing, access and
parking code is identified in the assessment criteria column in a table of
assessment in section 5.5–Levels of assessment-Material change of use in Part
5–Tables of assessment;
(ii)
that is made impact assessable in a table of assessment in section 5.5–Levels of
assessment-Material change of use or Section 5.9–Levels of assessment–Local
plans in Part 5–Tables of assessment;
(b)
reconfiguring a lot:
(i)
that is code assessable and for which the Servicing, access and parking code is
identified in the assessment criteria column in Table 5.6.1–Reconfiguring a lot in
Part 5–Tables of assessment;
(ii)
made impact assessable in Table 5.6.1–Reconfiguring a lot in Part 5–Tables of
assessment;
(c)
operational work being a driveway crossover or infrastructure work that is constructing a
car park area that is self-assessable or code assessable and for which the Servicing,
access and parking code is identified in the assessment criteria column Table 5.8.1–
Operational work in Part 5–Tables of assessment.
When using this code, reference should be made to section 5.3.2–Determining the level of
assessment and, where applicable, section 5.3.3–Determining the assessment criteria located
in Part 5–Tables of assessment.
9.4.7.2
Purpose
(1)
The purpose of the code is to ensure that development satisfies the demand for parking and
provides safe, functional and legible parking, access and servicing.
(2)
The purpose of the code will be achieved through the following overall outcomes:
(a)
9.4.7.3
parking, access and servicing areas:
(i)
satisfy the expected demand for the number and type of vehicles, motorcycles and
bicycles;
(ii)
are safe and functional and have easy way finding;
(iii) protect the movement network.
Criteria for assessment
Part A–Criteria for self-assessable and assessable development
Table 9.4.7.3.1–Service, access and parking code: self-assessable and assessable
development
Performance outcomes
Acceptable outcomes
For self-assessable and assessable development
Provision of parking spaces for vehicles
Vehicle parking, loading and servicing and pick
up/set down areas are provided that satisfy the
expected demand for the number and type of
vehicles likely to be generated by a use having
regard to:
AO1
Vehicle parking, vehicle washing, loading and
servicing and pick up/set down areas are provided:
(a) for a use listed in Table 9.4.7.3.2–Vehicle
parking and servicing, to comply with columns
2 to 5 of Table 9.4.7.3.2–Vehicle parking and
servicing;
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-68
Performance outcomes
Acceptable outcomes
(a) the particular circumstances of the premises
including the:
(i) nature, intensity and hours of operation
of the use;
(ii) desirability of providing a car park and
attracting vehicles to the premises;
(iii) maximum number of employees and
customers to be on the premises at any
one time;
(iv) size, levels and dimensions of the
premises;
(b) the proximity of the premises to an existing or
future Parking station, other available car
park or public transport facility.
PO2
Development with a security gate provides
accessible visitor vehicle parking in front of the
security gate.
(b) for a use not listed in Table 9.4.7.3.2–Vehicle
parking and servicing, in accordance with a car
parking assessment report to be provided to
the local government and prepared in
accordance with Part 2 of planning scheme
policy 5–Infrastructure.
PO3
A car park not being a Parking station provides
free and unobstructed access for the use by
employees and visitors during the normal hours
of operation of the use.
Provision of motorcycle parking
PO4
Motorcycle parking is provided that is safe and
functional.
Provision of bicycle parking
PO5
Bicycle parking facilities are provided that:
(a) satisfy the likely demand for bicycle parking;
(b) are functional;
(c) are located close to a pedestrian entry to a
building.
Provision of vehicle manoeuvring area
PO6
Development provides a safe and functional
vehicle manoeuvring area.
Editor's note––For building work, Car parking for people with a
disability is to be provided in accordance with Table D3.5–
Carparking spaces for people with a disability in the Building
Code of Australia.
AO2
Development with a security gate provides visitor
vehicle parking that complies with Table 9.4.7.3.4–
Visitor parking spaces for uses incorporating a
security gate.
AO3
A use, other than a Residential activity or a Parking
station, provides vehicle parking that:
(a) is kept, used and maintained exclusively for car
parking;
(b) is accessible to all employees and visitors
during the normal hours of operation of the use
with no encumbrance, fee or charge;
(c) does not have a gate, door or similar device
that restricts vehicular access by employees or
visitors.
AO4
Motorcycle parking is provided to comply with
section 2.4.7 of AS2890.1:2004–Parking facilities–
Off street car parking.
AO5
Bicycle parking facilities comply with:
(a) the rate specified in column 7 of Table
9.4.7.3.2–Vehicle parking and servicing;
(b) AS2890.3–1993–Bicycle parking facilities.
AO6
Development provides a vehicle manoeuvring area
that:
(a) accommodates the design vehicle specified in
Table 9.4.7.3.5–Design vehicle for a
manoeuvring area;
(b) complies with section 3.4.4.10–Manoeuvring
areas of planning scheme policy 5–
Infrastructure.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-69
Performance outcomes
Vehicle washing bay
PO7
A vehicle washing bay does not cause
environmental harm.
Car park access
PO8
Vehicular access to a car parking area has
sufficient queuing space to ensure a vehicle does
not queue on a road, cycleway or footpath.
Driveway crossover
PO9
A driveway crossover is safe, functional and does
not adversely affect infrastructure.
Design and construction of a car parking area
PO10
A car parking area is designed to:
(a) provide easy way finding for pedestrians,
cyclists and motorists;
(b) provide appropriately sized and line marked
spaces in accordance with relevant
Australian standards;
(c) provide a convenient and safe pedestrian
network;
(d) provide safe and efficient vehicle circulation;
(e) provide a progressive reduction in the speed
environment in moving between the road and
a parking space;
(f) provide a safe sight distance at a potential
conflict point;
(g) provide for efficient and simple parking space
search patterns;
(h) provide for uncongested public transport and
service vehicle movements through the
premises;
(i) keeps a heavy vehicle out of a parking aisle;
(j) ensure no heavy vehicle reverses across a
pathway;
(k) prevent parking off a circulation road;
(l) prevent an adverse impact on the safety and
efficiency of the existing or planned
movement network;
Acceptable outcomes
AO7
A vehicle washing bay provides that run off is
discharged to:
(a) a grassed area or permeable landscape area;
or
(b) the sewerage system.
AO8
Vehicular queuing space to a car parking area:
(a) does not provide a turning movement,
intersecting aisle or a speed hump in a queuing
area;
(b) complies with:
(i) column 6 of Table 9.4.7.3.2–Vehicle
parking and servicing;
(ii) Table 9.4.7.3.3–Queuing spaces.
AO9
A driveway crossover is designed and constructed
to comply with section 3.4.5–Design standards for
access and driveways of planning scheme policy
5–Infrastructure.
AO10
A car parking area is designed and constructed in
accordance with section 3.4.6–Design standards
for car parking of planning scheme policy 5–
Infrastructure.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-70
Performance outcomes
Acceptable outcomes
(m) prevent a motorist from reversing on a road;
(n) prevent an unnecessary space that
encourages illegal parking;
(o) address safety of users through appropriate
lighting;
(p) be appropriately landscaped;
(q) be surfaced so as to be useable in all
weather conditions;
(r) manage stormwater flows.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-71
Table 9.4.7.3.2–Vehicle parking and servicing
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Adult store
1 space per 17m² of GFA
1 space per 100m² of GFA
√ (if more than
500m² GFA)
Not required
No minimum
1 space per
400m² GFA /
employee;
plus 1 visitor
space per
500m² GFA
Agricultural
supplies store
1 space per 100m² of site
area
Not applicable
√
Not required
No minimum
No minimum
Animal
husbandry
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Animal keeping
A minimum of either:
(a) 4 spaces, if the premises
is used for the boarding of
animals; or
(b) 2 spaces, if the premises
is not used for the boarding of
animals.
Not applicable
Not required
Not required
No minimum
No minimum
Aquaculture
1 space per employee; plus 1
visitor space.
Not applicable
√
Not required
No minimum
No minimum
Note––4 Where the premises are used for more than one use, the rates for each use are applicable.
Note––5 Where the calculated number of spaces is not a whole number, the number of spaces is rounded to the higher whole number.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-72
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Bar
1 space per 10m² of GFA bar
area (excluding staff only
areas); plus 1 space per 3
gaming machines for gaming
machines
1 space per 100m² of GFA.
√
Not required
No minimum
No minimum
Brothel
5 spaces per 100m2 of GFA
Not applicable
Not required
Not required
No minimum
No minimum
Bulk landscape
supplies
1 space per 400m² of site
area with a minimum of 6
spaces
Not applicable
√
Not required
No minimum
No minimum
Caretaker's
accommodation
1 covered space
Not applicable
Not required
Not required
No minimum
No minimum
Car wash
1 space per employee if not
part of a Service station
1 space per employee if not part
of a Service station.
Not required
Not required
4 vehicles per car
wash bay
No minimum
Child care centre
1 space per equivalent full
time employee based on the
maximum number of
employees on the premises
at any one time plus 1 space
per 10 approved places for
children
1 space per equivalent full time
employee based on the maximum
number of employees on the
premises at any one time plus 1
space per 10 approved places for
children
√
Not required
No minimum
No minimum
Club
1 space per 30m² of GFA
1 space per 100m² of GFA
√
√ (if more than
2000m² GFA)
No minimum
No minimum
Community care
centre
1 space per equivalent full
time employee, based on the
maximum number of
employees on the premises
1 space per equivalent full time
employee, based on the
maximum number of employees
√
√
No minimum
No minimum
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-73
Column 1
4
Use
Column 2
Minimum number of
parking spaces5
at any one time plus 1 space
per 10 visitors
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
on the premises at any one time
plus 1 space per 10 visitors
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Community
residence
1 space per employee plus 1
visitor space with a minimum
of 2 spaces
Not applicable
Not required
Not required
No minimum
No minimum
Crematorium
1 space per employee
Not applicable
√
√
No minimum
No minimum.
Cropping
No minimum
Not applicable
√
Not required
No minimum
No minimum
Dual occupancy
2 spaces per dwelling, 1 of
which is covered
Not applicable
Not required
Not required
No minimum
No minimum
Dwelling unit
1 space
Not applicable
Not required
Not required
No minimum
No minimum
Educational
establishment
1 space per employee; plus
1 space per 5 students for
year 12 students and above;
plus 1 visitor space per 10
students and 1 bus space per
50 students
1 space per 1 employee; plus 1
space per 5 students for year 12
students and above; plus 1
visitor space per 10 students and
1 bus space per 50 students
√
√
No minimum
Not specified
Emergency
services
Sufficient spaces to
accommodate the number of
vehicles likely to be parked at
any one time
Not applicable
√
√
No minimum
No minimum
Environment
facility
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
Note––Part
MP4.1 Sustainable
Buildings of the
QDC contains
requirements for
End of Trip
Facilities.
P9-74
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Extractive
industry
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Food and drink
outlet
1 space per 10m² of GFA up
to 400m² GFA, thereafter 1
space per 20m² GFA; plus 2
spaces per 10m² of GFA for
an outdoor seating area.
1 space per 100m² of GFA
√
Not required
10 vehicles per
drive through
facility
1 space per
30m² GFA.
Function facility
1 space per 17m² of GFA
1 space per 100m² of GFA
√
√ ( if more than
2000m² GFA)
No minimum
No minimum
Funeral parlour
1 space per employee; plus 1
space per 10m² of GFA
associated with a chapel
Not applicable
√
√
No minimum
No minimum
Garden centre
1 space per 300m² of display
area with a minimum of 6
spaces; plus 1 space per
20m² of indoor retail use area
1 space per 100m² of GFA
√
Not required
No minimum
No minimum
Hardware and
trade supplies
1 space per 60m² of GFA
1 space per 100m² of GFA
√
Not required
8 vehicles in any
drive in
No minimum
Health care
services
1 space per 10m² of GFA;
plus 1 ambulance space
1 space per 100m² of GFA
√
√
No minimum
1 space per
400m² GFA
for
employees;
plus 1 visitor
space per
200m² GFA
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-75
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
High impact
industry
1 space per 150m² of GFA up
to 900m²; plus 1 space per
200m² GFA thereafter
Not applicable
√
Not required
No minimum
1 space per
800m² GFA
for
employees.
Home based
business ( not
being guest
accommodation)
1 space plus 1 space per
non- resident staff member in
addition to the spaces
required for the Dwelling
house or Dwelling unit
Not applicable
Not required
Not required
No minimum
No minimum
Home based
business ( being
guest
accommodation)
1 space per bedroom to be
utilised for the guest
accommodation in addition to
the spaces required for the
Dwelling unit
Not applicable
Not required
Not required
No minimum
No minimum
Hospital
1 space per 10m² of GFA;
plus 1 ambulance space
1 space per 100m² of GFA
√
√
No minimum
Not specified
1 space per guest room; plus
1 space per 10m² of GFA for
lounge, bar and beer garden
area (excluding staff only
areas); plus 1 space per 35m²
GFA of liquor sales area; plus
1 space per 100m² of GFA
Hotel
Note––Part
MP4.1 Sustainable
Buildings of the
QDC contains
requirements for
End of Trip
Facilities.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
√
√
12 vehicles per
drive through
facility
1 space per
50m² of GFA
for lounge,
bar and beer
garden area;
plus 1 space
P9-76
Column 1
4
Use
Column 2
Minimum number of
parking spaces5
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
1 space per 5m² of GFA for
gaming machines
per 60m² of
GFA for
gaming
machines
Indoor sport and
recreation
1 space per 15m² of GFA
1 space per 15m² of GFA
√
√
−
3 spaces;
plus 1 space
per 50m²
GFA for
visitors
Intensive animal
industry
1 space
Not applicable
Not required
Not required
No minimum
No minimum
Intensive
horticulture
Sufficient spaces to
accommodate the number of
vehicles likely to be parked at
any one time
Not applicable
Not required
Not required
No minimum
No minimum
Landing
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Low impact
industry
1 space per 50m² of GFA up
to 500m²; plus 1 space per
100m² GFA thereafter
Not applicable
√
Not required
No minimum
1 space per
800m² GFA
for
employees
Major electricity
infrastructure
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Market
1 space per 5m² of GFA of
the stalls and the displays
Not applicable
√
Not required
No minimum
1 space per
10 stalls
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-77
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Medium impact
industry
1 space per 80m² of GFA up
to 500m²; plus 1 space per
100m² GFA thereafter
Not applicable
√
Not required
No minimum
1 space per
800m² GFA
for
employees
Multiple dwelling
In the Loganlea local plan:
 1.15 covered spaces for
small (<75m2) or 1
bedroom dwellings; plus
 1.3 covered spaces for 2
bedroom dwellings and
above;
 0.4 visitor space per
dwelling; plus
 0.07 vehicle washing
space where the use
comprises more than 15
dwellings.
1 covered space per dwelling
√
√
No minimum
1 space per 3
dwelling units
plus 1 visitor
space per
dwelling 12
units
For all other land (unless
Column 3 applies):
 1.5 covered spaces for
small (<75m²) or 1
bedroom dwellings; plus
 2 spaces, including 1
covered space, for 2
bedroom dwellings and
above; plus
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-78
Column 1
4
Use
Column 2
Minimum number of
parking spaces5
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
 0.25 visitor space per
dwelling; plus
 1 vehicle washing space
where the use comprises
more than 15 dwellings
Nightclub
entertainment
facility
1 space per 100m² of GFA
plus 1 space per employee
Not applicable
√
√
No minimum
No minimum
Office
1 space per 20m² of GFA of
any storey at ground level;
plus 1 space per 30m² of
GFA of any other storey with
a minimum of 4 spaces; plus
2 visitors' spaces
1 space per 100m² of GFA
√
√
No minimum
Not specified.
Outdoor sales
1 space per 300m² of display
area; plus 1 space per 1.5
employees
Not applicable
Not required
Not required
No minimum
No minimum
Outdoor sport
and recreation
(where a bowling
green)
4 spaces for the first rink; plus
2 spaces for the subsequent
rink
4 spaces for the first rink; plus 2
spaces for the subsequent rink
√
√
No minimum
No minimum
Outdoor sport
and recreation
(where a court
game)
4 spaces per court
4 spaces per court
Not required.
√
No minimum
No minimum
Note––Part
MP4.1 Sustainable
Buildings of the
QDC contains
requirements for
End of Trip
Facilities.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-79
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Outdoor sport
and recreation
(where a golf
course)
40 spaces per 9 hole course
or 80 spaces for 18 hole
course
Not applicable
√
√
No minimum
No minimum
Outdoor sport
and recreation
(where a golf
driving range)
1 space per tee off area; plus
1 space per 20m² GFA of bar,
lounge and other
entertainment areas
Not applicable
Not required
√
No minimum
No minimum
Outdoor sport
and recreation
(where a
swimming pool)
15 spaces; plus 1 space per
100m² of GFA
15 spaces; plus 1 space per
100m² of GFA
√
√
No minimum
2 spaces per
20m² of pool
area
Outdoor sport
and recreation
(where outdoor
field games)
15 spaces per field
Not applicable
√
√
No minimum
No minimum
Outdoor sport
and recreation
(where a sport
arena)
1 space for every 3 seats plus
1 bus space per 100 seats
1 space for every 3 seats; plus 1
bus space per 100 seats
√
√
No minimum
1 space per
250 seats
Outdoor sport
and recreation
(other than those
above)
1 space per 15m² of GFA
1 space per 15m² of GFA
√
√
No minimum
No minimum
Park
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Parking station
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-80
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Permanent
plantation
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Place of worship
1 space per 10m² of GFA
1 space per 100m² of GFA
√
√
No minimum
No minimum
Port services
(where a marina)
1 space per 10 berths
Not applicable
Not required
Not required
No minimum
No minimum
Relocatable
home park
1 space per dwelling; plus
visitor car parking of 1 space
per 5 dwellings; plus 1 vehicle
washing space per 50
dwellings
Not applicable
Not required
Not required.
No minimum
No minimum.
Renewable
energy facility
No minimum
Not applicable
Not required
Not required.
No minimum
No minimum
Research and
technology
industry
1 space per 50m² of GFA up
to 500m²; plus 1 space per
100m² GFA thereafter
Not applicable
√
Not required.
No minimum
1 space per
800m² GFA
for
employees
Residential care
facility
1 space per 5 nursing home
beds; plus 1 space per
hostel- type unit; plus 1 space
per full time employee; plus 1
ambulance parking space
1 space per 5 nursing home bed;
plus 1 space per hostel- type unit;
plus 1 space per full time
employee; plus 1 ambulance
parking space
√
√
No minimum
No minimum
Resort complex
1 space per guest room; plus
1 space per 10m² of GFA for
lounge, bar and beer garden
area (excluding staff only
areas); plus 1 space per 35m²
GFA of liquor sales area; plus
1 space per 100m² of GFA
√
√
12 vehicles per
drive through
facility
1 space per
50m² of GFA
for lounge,
bar and beer
garden area;
plus 1 space
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-81
Column 1
4
Use
Column 2
Minimum number of
parking spaces5
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
1 space per 5m² of GFA for
gaming machines
per 60m² of
GFA for
gaming
machines
Retirement
facility
1 space per self-contained
unit; plus 1 visitor space per
10 units; plus 1 space per
fulltime employee 1
ambulance parking space
1 space per self -contained unit;
plus 1 visitor space per 10 units;
plus 1 space per fulltime
employee; plus 1 ambulance
parking space
√
√
No minimum
No minimum
Roadside stall
No minimum
Not applicable
Not required
Not required
No minimum
No minimum
Rooming
accommodation
0.25 spaces per rented room
0.25 spaces per rented room
Not required
Not required
No minimum
1 space per 4
rented room
Rural industry
Sufficient spaces to
accommodate the number of
vehicles likely to be parked at
any one time
Not applicable
√
Not required
No minimum
No minimum
Rural workers’
accommodation
1 space per bedroom
Not applicable
Not required
Not required
No minimum
No minimum
Sales office
1 space per employee where
for an estate Sales office or
display dwelling.
1 space per employee with a
minimum of 4 spaces where
for a cluster of display
dwellings
1 space per employee with a
minimum of 4 spaces
Not required
Not required
No minimum
1 space per
200m² GFA
for
employees
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-82
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Service industry
(where a car
rental
establishment)
1 space per 25m² of GFA;
plus 1 space per 1.5 vehicles
in a hire vehicle fleet that may
be provided in tandem
1 space per 100m² of GFA; plus 1
space per 1.5 vehicles in a hire
vehicle fleet that may be provided
in tandem
Not required
Not required
No minimum
1 space per
200m² GFA
for
employees
Service industry
(where not a car
rental
establishment)
1 space per 25m² of GFA
1 space per 100m² of GFA
Not required
Not required
No minimum
1 space per
200m² GFA
for
employees
Service station
2 spaces; plus 1 space per
25m² of GFA for a shop of
less than 150m²; plus 1
spaces per 20m² of GFA of
shop area exceeding 150m²;
plus 1 space per 10m² of
GFA for food and drink outlet;
plus 5 spaces per vehicle
service bay.
2 spaces; plus 1 spaces per 25m²
of GFA for a shop of less than
150m²; plus 1 spaces per 20m² of
GFA of shop area exceeding
150m²; plus 1 space per 10m² of
GFA for food and drink outlet;
plus 5 spaces per service bay.
Editor's note - tandem car parking
may be acceptable for service or
staff vehicles
√
Not required
3 vehicles from a
fuel outlet.
Where a carwash
is associated with
the service
station, at least 4
vehicles are
provided before
the carwash
entrance
1 space per
200m² GFA
for
employees
Editor's note––Editor's note -tandem
car parking is acceptable for service
or staff vehicles
Shop
1 space per 17m² of GFA
1 space per 100m² of GFA
√
Not required
No minimum
1 space per
300m GFA
Shopping centre
1 space per 17m² of GFA for
a floor area of 1-10,000m²
GFA
1 space per 20m² of GFA for
a floor area >10,00030,000m² GFA.
1 space per 100m² of GFA
√
√
No minimum
Not specified.
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
Note––Part
MP4.1 Sustainable
Buildings of the
QDC contains
requirements for
P9-83
Column 1
4
Use
Column 2
Minimum number of
parking spaces5
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
End of Trip
Facilities.
1 space per 23m² of GFA for
a floor area of >30,000m²
GFA
Short-term
accommodation
1 space per residential unit;
plus 1 visitor space per 2
residential units; plus 1 space
for a manager resident on
the premises; plus 1 space
for 20m² of GFA of a
restaurant, common room,
catering and conference
facility.
1 vehicle washing space.
1 space per unit
√
√
2 vehicles at the
entry of the site
1 space per 5
residential
units plus 1
visitor space
per 4
residential
units
Showroom
1 space per 35m² of GFA
1 space per 100m² of GFA
√
Not required
No minimum
1 space per
750m² GFA
for
employees;
plus 1 visitor
space per
1000m² GFA
Special industry
1 space per 150m² of GFA up
to 900m²; plus 1 space per
200m² GFA thereafter
Not applicable
√
Not required
No minimum
1 space per
800m² GFA
for
employees
Substation
1 space
Not applicable
Not required
Not required
No minimum
No minimum
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-84
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Telecommunicati
ons facility
1 space per employee with a
minimum of 2 spaces
Not applicable
Not required
Not required
No minimum
No minimum
Theatre
1 space per 8 seats
1 space per 100m² of GFA
Not required
Not required
No minimum
No minimum
Transport depot
1 car space for every truck
space; plus 1 space per 2
non-driver employees
Not applicable
√
Not required
No minimum
No minimum
Tourist park
1 space per site; plus 1 visitor
space per 10 sites; plus 1
vehicle washing space per 20
sites; plus 1 space for a
manager resident on the
premises
Not applicable
Not required
Not required
2 vehicles at the
entry of the site
No minimum
Utility installation
1 space per employee with a
minimum of 2 spaces
Not applicable
√
Not required
No minimum
No minimum
Veterinary
services
1 space per 30m² of GFA
1 space per 100m² of GFA
√
√
No minimum
No minimum
Warehouse ( not
being a ministorage
establishment)
1 space per 100m² of GFA
Not applicable
√
Not required
No minimum
No minimum
Warehouse
(being a ministorage
establishment)
1 space per 100 storage
units; plus 1 space per
employee
Minimum traffic circulation
accessway width of 6.5m
Not applicable.
√
Not required
No minimum
No minimum
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-85
Column 1
4
Column 2
Column 3
Minimum number of parking
spaces for a:
(a) Centre zone where a principal
centre or major centre;
(b) Medium density residential
zone where not at Browns
Plains or Park Ridge.
Column 4
Column 5
Column 6
Column 7
Loading bay
Pick-up / set
down areas
Minimum
provision for
queuing (in
addition to
Table 9.4.7.3.3–
Queuing
spaces)
Minimum
number of
bicycle
spaces
Use
Minimum number of
parking spaces5
Wholesale
nursery
1 space per employee; plus 1
visitor space.
Not applicable
√
Not required
No minimum
No minimum
Winery
1 space per 10m² of GFA up
to 400m² GFA for retail and
dining areas only, thereafter 1
space per 20m² GFA for retail
and dining areas only; plus 2
spaces per 10m² of GFA for
an outdoor seating area.
1 space per 100m² of GFA
√
Not required
No minimum
1 space per
30m² GFA for
retail and
dining areas
only
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-86
Table 9.4.7.3.3–Queuing spaces
Column 1
Column 2
Static capacity of car park
Minimum number of vehicles in queue ¹
1-30
2
31-60
2
61-100
3
>100
The number calculated complies with Table 3.3 of AS
2890.1:2004 Parking facilities - Off-street car parking
Note––For the purposes of calculating queue length, each car length is 6 metres and the queue distance is measured from the
boundary of the premises at a crossover to the first available car parking space on the premises.
Table 9.4.7.3.4–Visitor parking spaces for uses incorporating a security gate
Column 1
Column 2
Total number of visitor car
parking spaces provided on the
premises
Minimum number of visitor car parking spaces
required in front of a security gate
<6
0
6-10
2
11-20
4
21-30
6
31-40
8
41-50
10
>50
Visitor car parking spaces to accommodate the amount of
vehicular traffic likely to be generated by the use
Table 9.4.7.3.5–Design vehicle for a manoeuvring area
Column 1
Column 2
Use or user class
Design vehicle¹
Adult store
SRV, if less than 500m² GFA
MRV if 500m² or greater GFA
Agricultural supplies store
AV
Animal keeping
MRV
Aquaculture
HRV
Bulk landscape supplies
HRV
Childcare centre
SRV
Club
HRV
Community care centre
MRV
Crematorium
SRV
Cropping
AV
Educational establishment
HRV/bus
Environment facility
HRV
Food and drink outlet
MRV, if less than200m² GFA
HRV, if 200m² or greater GFA
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-87
Column 1
Column 2
Use or user class
Design vehicle¹
Function facility
HRV
Funeral parlour
SRV
Garden centre
HRV
Hardware and trade supplies
HRV
Health care services
SRV
High impact industry
AV
Hotel
HRV
Indoor sport and recreation
HRV
Intensive animal husbandry
AV
Intensive horticulture
AV
Low impact industry
HRV
Market
HRV
Medium impact industry
HRV
Multiple dwelling
SRV if comprising 6 to 10 dwellings;
HRV if comprising more than 10 dwellings
Night club entertainment facility
HRV
Office
MRV, if less than 1000m² GFA
HRV, if 1000m² or greater GFA
Outdoor sales
AV
Outdoor sport and recreation
HRV/bus
Parking station
B99
Place of worship
SRV
Research and technology
industry
HRV
Residential care facility
HRV
Relocatable home park
HRV = bus
Retirement facility
HRV = bus
Rooming accommodation
HRV
Rural industry
AV
Service industry
AV
Service station
AV
Shop
MRV, if less than 500m² GFA
HRV, if 500m² or greater GFA
Shopping centre
AV
Short term accommodation
HRV
Showroom
HRV
Theatre
HRV
Transport depot
AV
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-88
Column 1
Column 2
Use or user class
Design vehicle¹
Utility installation
HRV
Wholesale nursery
AV
Warehouse (where a mini
storage establishment)
HRV
Warehouse
AV/HRV
Veterinary services
SRV
Use not specific in column 1
Design vehicle specified by the local government
Editor's note––B99 = a car
Editor's note––SRV = a small rigid vehicle or ambulance
Editor's note––MRV = a medium rigid vehicle
Editor's note––HRV = a heavy rigid vehicle
Editor's note––AV = an articulated vehicle
Part 9 Development codes - 9.4.7 Servicing, access and parking code
Logan Planning Scheme 2015 version 1.1
P9-89
Download