™ THE NEW POWER PROTECTION FOR DIGITAL SYSTEMS Ground noise must be eliminated for your digital systems to work properly. Every wall outlet provides the power to make your business work... or fail. Each day in offices everywhere, systems crash, error codes and lock-ups mysteriously materialize, and re-boots are par for the course. The culprit is ground noise; electricity that is not compatible with the sophisticated circuitry of digital and multi-function equipment. Service technicians will tell you that ground noise is responsible for most logic malfunctions. It causes more jams, mis-feeds, and lock-ups than any other source. It cannot be fixed by software upgrades or replacement circuit boards. How can you refine that “dirty power” and eliminate damaging ground noise without investing in an expensive isolation transformer? The Digital QC is the only product that can eliminate ground noise cost-effectively. ESP’s Digital QC features a revolutionary detect and correct system to eliminate ground noise. Our two-step process first detects the power line and verifies that it is properly wired. Then, it corrects ground noise levels by engaging the patented Zero Voltage Ground circuit. ESP’s Patented Zero Voltage Ground Technology... • Increases Up-Time by upgrading to computer-level power • Protects Data by eliminating harmful ground noise • Extends Equipment Life by protecting your digital equipment from dirty power • Boosts Reliability by removing the biggest cause of jams, mis-feeds and lock-ups • Lowers Ownership Costs by safe-guarding sensitive circuitry and Network and Internet/Modem connections • Exclusive Ground Window, a single point grounding inside the Digital QC eliminates ground loop window potential. • Meets the ANSI/IEEE 62.41 National “No Upset” Threshold Standard. Comes With Our Catastrophic Equipment Protection Guarantee promising that if your electronic equipment is damaged due to a severe power surge or lightning hit, ESP warranties the repair or replacement of your equipment at no cost to you... a level of protection superior to your present warranty or service contract. The Digital QC provides clean power to your business, at a fraction of the cost of an isolation transformer. By eliminating ground noise Digital QC safeguards your sensitive equipment, boosting productivity and protecting revenues. ™ Zero Voltage Ground is a high capacitance neutral to ground circuit. Now, combined with the Digital QC’s patented power scrubbing circuit and communications ground window, you have the ultimate in real power protection for digital equipment. The business office has moved into the digital realm. Isn’t it time to move power protection there too? ® REAL POWER PROTECTION BREAKTHROUGH TECHNOLOGY ELIMINATES GROUND NOISE About Our “Ground”breaking Technology... According to OEM specifications, anything over half a volt noise on ground compromises digital equipment peak performance; it’s unacceptable. Equipment protected by ESP’s Digital QC technology have virtually no noise on ground. Sensitive microprocessors— computers, digital phone systems, Internet/ Modem and Network connections—are protected; the OEM spec is met. And at a fraction of the cost of similar power protection systems. Digital QC System Configurations - As simple as 1-2-3. Begin with the Digital QC and select one option from each of the following three columns: Voltage Amperage Network & Modem 120 or 208/240 Volts 15 or 20 Amps Yes or No For example: Digital QC +120 Volts + 20 Amps + Network/Modem Bonus Configuration: For workstations, desktop computers and file servers, just specify the Digital QC Workstation. It is a 120 Volt, 15 Amps with Network & Modem, patch cords and an On/Off switch. S P E C I F completely eliminate GROUND NOISE. The noise that you can see on the ground line is eliminated by the Digital QC. Noise that will disrupt the operation of a Micro Processor, the brains of every Digital System. ESP’s patented Zero Voltage Ground circuit, after detecting the correct wiring and making sure there aren’t any ground or neutral faults, switches on the Zero Voltage Ground Circuit. 120V Digital Network Series has 4 AC Receptacles ON/OFF switch replaces female cord Locking Strap (keeps you protected) Power Cords specific to each Digital Network/Workstation Series has 4 RJ45 Ports & Patch cords Volt/Amp configuration 120V 15A 208V 20A 15A 20A ® REAL POWER PROTECTION Number ONE in Power Protection Technology! 800-645-9721 or FAX: 919-269-0454 517 North Industrial Drive, Zebulon, NC 27597 • email: ESP@realpowerprotection.com Website: www.realpowerprotection.com A T I O N S Digital QC 208 Volt Approval Standards Best UL 1449 Rating in the Industry Exceeds ANSI C62.41 Category A&B Withstands FCC Part 68 Surge Standard Complies with UL 497A Standard Complies with UL 498 Plug & Receptacles Complies with UL 991 Reliability Standard Complies with UL 1283 EMI Filter Standard Complies with UL 1363 Power Tap Standard Mil Std 40 Year Design Life UL Safety Certified CSA Approved 330 Volts >10,000 hits Yes Yes Yes Yes Full EMI filter Yes No time limit warranty UL Listed 73Z3 cUL Listed 73Z3 <700 Volts >10,000 hits Yes Yes Yes Full EMI filter Yes No time limit warranty UL Listed 73Z3 cUL Listed 73Z3 Physical Characteristics Dimensions - Length Dimensions - Width Dimensions - Height Shipping Weight Shipping Volume Mounting Means 8” 6.25” 2” 2.8 lbs 295 Cubic Inches Velcro 8” 6.25” 2” 3.4 lbs 295 Cubic Inches Velcro 5’ cord with NEMA 5-15 or 5-20 plug 6” cord with NEMA 5-15 or 5-20 receptacle 4 NEMA 5-15 flush receptacles 5’ cord with NEMA 6-15 or 6-20 plug 6” cord with NEMA 6-15 or 6-20 receptacle None 140 VAC 15 or 20 Amps 15 or 20 A fuse 250 VAC 15 or 20 Amps 15 or 20 A fuse Green Light = OK Green Light = OK Green Light = OK <3.5 mA >99.2% @ 15A <0.033 Ohm Yes N/A Green Light = OK N/A <0.5 mA >99% @ 20A <0.030 Ohm Yes < 5 nS Yes <6 V Millivolts 306 V pk 299 V pk 70 V pk 13000 A pk (Less is better) 0.031 J 0.054 J 0.758 J 0.185 J 1.030 J 330 V < 5 nS Yes <17 V <40 V 695 V pk 495 V pk 495 V pk 19500 A pk (Less is better) 0.326 J 0.327 J 2.439 J 0.431 J 3.523 J 700 V Series Filter Series Filter >53rd harmonic >48th harmonic >3rd harmonic >83rd harmonic >68th harmonic >68th harmonic 1.5 kHz - >50 MHz 6 kHz - >50 MHz 39 kHz - >50 MHz 78 kHZ - 600 kHz 2nd 12.2 µF 4.5 kHz - 42 MHz 43 kHz - 39 MHz 55 kHz - 17 Mhz 70 kHz - 2.3 MHz 2nd 4.4 µF 2.9 kHz - >50 MHz 9.8 kHz - >50 MHz 149 kHz - >50 MHz 4.4 MHz - 18 MHz 3rd 0.0047 µF 27 µH yes 18 kHz - 50 MHz 65 kHz - 50 MHz 170 kHz - 13 MHz 600 kHz - 2.3 MHz 3rd 0.004 µF 2.8 mH yes <50 kHz - >50 MHz 10 µF n/a Telephone Line Suppression Internet/Modem Connections Thru-put Resistance Response Time Clamp Voltage FCC Part 68 Metallic Waveform Clamp Voltage FCC Part 68 Longitudinal Waveform Maximum Surge Current Withstand for 160 µsec Residual Energy Let-thru in Joules All Modes FCC Part 68 Metallic Waveform All Modes FCC Part 68 Longitudinal Waveform Total Residual Energy Let-thru All Modes With Network Option RJ-11 or RJ-45 In/Out 14 Ohms <10 nS 329 Volts 347 Volts 200 Amps (Less is better) 0.007 J 0.004 J 0.011 J With Network Option RJ-11 or RJ-45 In/Out 14 Ohms <10 nS 329 Volts 347 Volts 200 Amps (Less is better) 0.007 J 0.004 J 0.011 J Network Protection Network Connections Protected Lines Clamp Voltage 6kV 0.25kA Peak Pulse Power Response Time Data Transmission With Network Option RJ-45 In/Out 1,2,3 & 6 11.5 Volts @ 143 Amps 15kW (10 µSec) < 1 Pico Second 10/100 Base T (100 MB/Sec Max) With Network Option RJ-45 In/Out 1,2,3 & 6 11.5 Volts @ 143 Amps 15kW (10 µSec) < 1 Pico Second 10/100 Base T (100 MB/Sec Max) Input Connection - AC Output Connection - AC Electrical Characteristics Maximum Line Voltage Maximum Load Current Overload Protection Operational Status • Reverse Polarity • Open Ground • Open Neutral Leakage Current Steady State Efficiency Thru-put Resistance Patented Hybrid Circuitry Voltage Suppression Response Time Sine Wave Tracking 6kV 1mA 1mhz - Normal Mode 6kV 1mA 1mhz - Common Mode Clamp Voltage 6kV 3kA - Normal Mode Clamp Voltage 6kV 3kA - Common Mode (L-G) Clamp Voltage 6kV 3kA - Common Mode (N-G) Maximum Surge Current Withstand for 20 µsec Residual Energy Let-thru in Joules All Modes IEEE C62.41 Category A Ringwave All Modes IEEE C62.41 Category B Ringwave All Modes IEEE C62.41 Category B Impulse All Modes UL 1449 Total Residual Energy Let-thru All Modes Lowest UL 1449 Rating Frequency Attenuation Response Time - Instant On Harmonic Suppression Normal Mode Common Mode (L-G) Common Mode (N-G) Digital QC Workstation C Digital QC 120 Volt Additional AC Output Connection Zero Voltage Ground - For the first time ever, this breakthrough technology can I Product Name Normal Mode > 10 dB (3.16 times Reduction Factor) > 20 dB (10.0 times Reduction Factor) > 30 dB (31.6 times Reduction Factor) > 40 dB (100.00 times Reduction Factor) Filter Order Capacitance Value Common Mode (L-G) > 10 dB (3.16 times Reduction Factor) > 20 dB (10.0 times Reduction Factor) > 30 dB (31.6 times Reduction Factor) > 40 dB (100.00 times Reduction Factor) Filter Order Capacitance Value Induction Value Sine Wave Tracking Common Mode (N-G) > 40 dB (100.0 times Reduction Factor) Capacitance Value © 2001 Electronic Systems Protection, Inc.