Quantum Sec 03

advertisement
Home
QuantumTM Dual Coil
Explosionproof
Integrated within a high impact aluminum enclosure meeting NEMA 4,
4X, 7, 9, Class I, Groups C & D,
Class II, Groups E, F, & G, Division
1 and 2 explosionproof requirements and certified to Factory
Mutual and Canadian Standards,
the QuantumTM standardly houses
two high current mechanical or
MagnumTM proximity sensors and a
wide range of integrated dual coil
FalconTM solenoid valves in fourway configurations. Falcon
solenoid valves are available in a
variety of coil voltages and body
materials with stainless steel
internals as standard. Cv. values
range from .3 to 1.2.
Low Power Control Monitor
for use in Explosionproof
Hazardous Areas
Micro-Switch V3
Standard
Sensor
Options
SPDT Form C, UL, CSA
AMPS
15
15
6
,5
.25
SPDT (V3)
VAC
125
250
VDC
AMPS
10
10
10
24
125
250
DPDT (Licon)
VAC
VDC
125
250
28
MagPacTM Modular Sensors
mA
VAC
VDC
Bifurcated Reed Proximity Sensor,
SPST • FM, CSA (Hermetically Sealed)
2-750
120
120
2-750
24
MAGNUMTM Proximity Sensors
High Current Proximity Sensor, SPST/SPDT Form C • UL, CSA (Hermetically Sealed)
!
ATTENTION
Rhodium
Magnum and Proximity Sensors Only
Amps
For low power (P ≤ 240 mW) and/or
high DI card capacitance (C ≥ 0.01 mfd.)
applications refer to the Reference Section
Bulletin No. WD-13.02 or specify the
MagPAC sensor module.
VAC
0.295
120
0.15
240
Tungsten
VDC
1
TM
FALCON
24
VAC
3
120
1.5
240
2
VDC
24
COIL POWER SUPPLY
LOW POWER SOLENOID TECHNOLOGY
Operating Voltage
Wattage
Operating Current
Coil Resistance
BULLETIN NO. Q-16.02
Amps
24 VDC
COILS
120 VAC
125 VDC
220 VAC
0.55 Watts
4 Watts
1 Watts
4 Watts
22 mA
27 mA
8.60 mA
17.5 mA
1050 Ohms 1100 Ohms 14500 Ohms 3750 Ohms
Home
QuantumTM Dual Coil
Explosionproof
DIMENSIONS (inches/mm)
AREA CLASSIFICATIONS
Model 877
NEMA 4, 4x, 7, 9
Class I, Groups C, D
Class II, Groups E, F, G, Div. 1 & 2
2.34 DIA.
59
3.26
83
2.94
75
OPEN
4.38
111
7.31
7.85
199
186
(FALCONTM SOLENOID)
5.73
146
OPEN
ORDERING GUIDE
6.75
171
B
BEACON
OPEN
COILS
CV
Body
4-Way
2.73
69
A
XSO
Brass
24 VDC
0.55 watts
Alum.
3900
303 S.S.
4900
316 S.S.
5900
Brass
2000
Alum.
3000
303 SS
4000
316 S.S.
5000
Brass
2Y00
Alum.
3Y00
303 S.S.
4Y00
.3 Cv
XAO
120 VAC
4.0 watts
XVO
.5 Cv
125 VDC
1.0 watts
XHO
220 VAC
4.0 watts
1.2 Cv
2900
.375 DIA.
.25
6
9.52
.250 +.000 FLAT
6.35 -.002
3.5 Cv
Alum.
3/4" NPT
CONDUIT
ENTRY
.56
14
6.52
166
D
TOP VIEW
SIDE VIEW
5/16 - 18 UNC TAP
.50 DP, 4 PLC'S
1.12
28.5
2.25
57 SQU
.350
8.89
1.30
33
.156
3.96
+.000
-.001
.157
3.98
FLAT
.375 DIA
9.53
BOTTOM VIEW
OPTIONAL NAMUR SHAFT
A
5Y00
3Z00
.191
DIA
4.85
Dimensions
Solenoid Valve
316 S.S.
C
B
C
D
3.15
3.41
.3 & .5 Cv
1.50
5.13
1.13
1.2 Cv
2.00
6.69
1.38
OPTIONAL FEATURES (See BULLETIN NO. Q-18.02)
Note: Minimum operating pressure: 45 psi.
ORDERING GUIDE
QUANTUMTM LP
877
BEACONTM
3-WAY BEACONTM
STANDARD
(Black & Yellow) BY
90° Rotation B1
SENSOR
Mech. (SPDT)
M2
Aluminum
Mech. (DPDT)
OPEN
NEMA 4, 4x, 7, 9
Class I, Groups C, D
Class II, Groups E, F, G,
Division 1 & 2
ANSI YELLOW
(Inherently Hazardous) AY
90° Rotation B3
ANSI GREEN
(Liquid-Low Hazard) AG
90° Rotation B5
ANSI BLUE
(Gas-Low Hazard) AB
180° Rotation B7
ANSI RED
(Fire Quenching) AR
180° Rotation B9
SOLENOID
(FalconTM)
Use above listing
for ordering solenoid
M4
Magnum (SPDT)
M6
Magnum (SPST)
M7
MagPAC 2 (SPST) Module
w/ LED indication
M13
TRAMSMITTERS
1000 ohms
RS
4-20 mA
CS
Ordering Example: Quantum LP Explosionproof, aluminum enclosure with standard black & yellow Beacon, 2 Magnum Sensors and
Falcon 120 VAC/4.0 watts, .5 Cv, brass, 4-Way solenoid valve. 877-BY-M6-XAO-2000
Westlock reserves the right to change product designs and specifications
without notice, and is not responsible for errors and omissions.
Download