Moonlite LED ™ Outdoor Egress Emergency & Security Light T he B righte s t I de a Architectural Emergency Light Series MAE ."& is E m e r ge nc y L ighting w ith L E Ds GENERAL DESCRIPTION t "ESBNBUJDOFXBOEDPNQBDUBSDIJUFDUVSBMEFTJHO QSPWJEJOHQPXFSGVMFNFSHFODZBOEOPSNBMMJHIUJOHGPSPWFS EPPSBOEPUIFSFYUFSJPSMPDBUJPOTXJUIGVMM¡DVUPò5IF MBNQIPVTJOHBOEDBOPQZBSFGBCSJDBUFEGSPNFYUSVEFE BMVNJOVNJOFOBNFMPSBOPEJ[FEöOJTIFTXJUISVHHFE TFBMFEEJòVTFSMFOTBOETUBJOMFTTIBSEXBSFGPSVOJWFSTBM XBMMPSDFJMJOHNPVOU series MAE CONSTRUCTION t&YUSFNFMZMPXQSPöMFGPSNFEBMVNJOVNIPVTJOH 4UBOEBSEöOJTIJTXIJUFTBUJOQBJOUDVTUPNDPMPSTBSF BWBJMBCMFJODMVEJOHCSVTIFEBMVNJOVNBOPEJ[FEöOJTIFT t8FUMPDBUJPOMJTUFE*1 ENERGY EFFICIENT OPERATION t%VBMGVODUJPOPQFSBUJPOGPSOPSNBMMZPOOJHIUPS TFDVSJUZMJHIUJOHBTXFMMBTFNFSHFODZMJHIUJOH t'VMM¡DVUPò t7FSZMPXQPXFSDPOTVNQUJPOJOOJHIUTFDVSJUZ NPEF5IFTFDVSJUZMJHIUJOHDJSDVJUJTJOEFQFOEFOU PGFNFSHFODZMJHIUJOHBOENBZCFTXJUDIFE NBOVBMMZCZBOFYUFSJPSQIPUPDFMMPSPUIFS BVUPNBUJDNFBOT t5ISFFWFSTJPOTBSFBWBJMBCMF t0WFSIPVSMBNQMJGFJOOPSNBMVTF t*&4QIPUPNFUSJDEBUBBWBJMBCMFGPSBMMNPEFMT t6OJGPSNFMPOHBUFEMJHIUJOHQBUUFSOPWFSSFRVJSFEQBUIPG &HSFTT RE $FOUSBM#BUUFSZ4ZTUFN4FSJFT$#4PS PUIFSRVBMJöFETPVSDF77%$ BB #BUUFSZ#BDLVQ AC 7"$TVQQMZ CODES ELECTRONICS t.BOVGBDUVSFEBOEUFTUFEUP6-4U BOEBSEBOE /'1" -JGF4BGFUZ$PEF t-BNQTBSFDPOOFDUFEJOQBSBMMFM*GPOFMBNQGBJMT POFPSNPSFMBNQTXJMMDPOUJOVFJOPQFSBUJPO WARRANTY t6OJWFSTBM7"$JOQVUGPSTUBOEBSECBUUFSZPS "$VOJUPS7%$JOQVUGPSSFNPUFDPOöHVSBUJPO tZFBSUPUBMDVTUPNFSTBUJTGBDUJPOXBSSBOUZ'PS EFUBJMTTFFQSPEVDUDBUBMPHUFDIOJDBMEBUBTFDUJPO t1PXFSTVQQMZEFMJWFSTSFHVMBUFEDVSSFOUBOEWPMUBHF UP-&%MBNQTBUPQUJNVNMFWFMTUPNBYJNJ[FMBNQ MJGF t"VUPNBUJDCBUUFSZEJBHOPTUJDTBWBJMBCMFGPSBMMCBUUFSZ .PEFMT D E S I G N E D & M A D E I N IN T E R TE K CM T H E U S A L IS T E D 2003529 US Moonlite LED ™ Outdoor Egress Emergency & Security Light Architectural Emergency Light Series MAE MAE.05.13.09 SPACING GUIDE SUGGESTED SPECIFICATIONS: Install MOONLITE™ Series MAE architectural emergency lighting fixture manufactured by Signtex Lighting, Inc. The MAE assembly shall be listed for installation in wet locations in compliance with UL 924 and IP66 standards, available as unit equipment or as a remote connected to a central battery power source. Upon loss of AC building power, lighting will be activated for a minimum of 90 minutes under battery power, in compliance with UL 924 and NFP A LSC Code 101. In remote configuration, the unit may be specified to operate continuously for security or night lighting, as required. The battery charger and power supply shall have universal input of 120/277 VAC, with brownout and L VD circuit protection. Auto battery diagnostics shall be available for all models and shall perform all test functions specified by UL 924 and NFPA 101. 25' 12' MO UN TIN G D ATA & D IME NS ION S: 9 1/2" 120/277 VAC SUPPLY 5" STANDARD DEEP J- BOX 4" x 4" x 2 1/8" BY OTHERS Average Illuminance 1 Fc Model Shown: MAE 10 Watts GASKET NOTE: FOR REFERENCE ONLY . STANDARD REFLECTANCES 80/50/20. SIGNTEX IS NOT RESPONSIBLE FOR SPECIFIC CONDITIONS THAT MAY ALTER THE RESULTS. WALL MOUNT CONTACT SIGNTEX FOR LA YOUT ASSISTANCE Code Compliant Emergency lighting layouts provided free of charge! 5" 1 1/2” EXTENSION RING P US H TO T E S T S TAT US INDIC ATOR TWO-GANG FIXTURE BOX: DIE CAST ALUMINUM 2” DEEP 28 CUBIC IN. (Supplied by others) EXAMPLE: BELL #5346-0 OR EQUAL 2 1 /4" 4 1/4" CEILING MOUNT 1 1/2" STANDARD SECURITY / NIGHT LIGHTING BB Models with SW Option RE Models (All) STATUS LED DISPLAY GR EEN O N OR ANG E O N R E D F L AS H F AS T G R E E N F L AS H OR ANG E F L AS H R E D F L AS H S LOW NOR MAL F UL L C HAR G E NOR MAL F AS T C HAR G E FAIL E D B AT TE R Y FAIL E D L AMP FAIL E D T R ANS F E R FAIL E D C HAR G E R 10 Connect ORANGE & GREEN wires together with dry contact switch to turn ON BB with DG Option = Connect RED wire to voltage source from 10V to 300V AC or DC to turn ON MAE MODEL SERIES MAE EXAMPLE: BB OPERATION RE= Remote with Central Battery System BB= Battery Backup AC= AC Supply 120/277V SURFACE MOUNT STANDARD - SURFACE MOUNT FITTED - (4) S C R E WS S TAINLE S S #6-32 TO MAT C H DE V IC E B OX = ORDERING INFORMATION: 3 3/4" BB MOD EL S WITH D G FU NC TIO N SW OPTION CONTROL WIRING Standard BB VAILABLE FOR RE MODELS ONL Y SE LF - T ES T DIAG NO ST IC F UN CT IO NS E M Watts S E C P ower- Watts 10 NOTE: SURFACE MOUNT A RECESSED J-BOX MOUNT MAEBB10WW-DG 10 POWER RATING 10= 10 Watts Emergency and Security (Normally On) W HOUSING COLOR W= Satin White A= Aluminum 'X'=Custom RATED IP 66: SUITABLE FOR WET LOCA W MOUNT T= Top W= Wall TIONS AMBIENT TEMPERATURE LIMITS: Standard "BB" models: -20º C to +40º C Remote models: -40º C to +50º C DG OPTIONS DG= Battery Diagnostics* SW= Security Lighting with Control Switch* SF= Surface Mount** SFF= Surface Mount Fitted** LT= Low T emp Operation to -40C*** *BB Models Only ** RE Models Only ***Requires RPS. See RPS spec sheet