ling FOR HEALTHCARE ENVIRONMENTS
table of contents
Surgical Suite Lighting
4-10
Patient Room Lighting
11–18
Mri/Imaging Suite Lighting
19–21
Healthcare Undercabinet Lighting
22–24
Additional Suggested Products
25–29
Specification Sheets 30–107
Listings Descriptions
108–113
LETTER FROM THE
PRESIDENT
Today’s healthcare facilities need lighting fixtures capable of
satisfying many demanding requirements, from meeting essential
environmental and safety criteria, to offering pleasing designs
and superior optical performance.
Kenall has applied its industry-leading expertise in creating fixtures
for demanding environments to expanding its family of healthcare
lighting systems, setting new benchmarks for safety, performance,
and durability in:
• Patient rooms,
• MRI facilities,
• Surgical suites, and
• Building exteriors.
Whether your project requires fixtures that stand up to the most
rigorous cleaning protocols (NSF2 Splash Zone), maintain critical
environmental barriers (NSF49 and IP65), or light surgical suites
effectively without disturbing sensitive electrical devices (MIL
STANDARD 461E – Air Force/Navy Fixed), you can specify Kenall
with confidence. See details on pages 108-113.
We have been dedicated to complete customer satisfaction for over
40 years, consistently offering the highest quality available. I invite
you to discover the benefits Kenall’s healthcare lighting can provide
to your project. You won’t be disappointed.
James Hawkins, President,
Kenall Manufacturing
2
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
What’s New in HEALTHCARE luminaires
Cleanscene™ csmec Lightbox
with exam compartments
(Page 17)
MEDMASTER™ Downlights
(Pages 8,15,19,21)
Cleanscene™ csmri led lightbox
for mri/Imaging applications
(Pages 19-21)
MedMaster™ m3se
Surgical procedural exam fixture
(see specification pages 73-78)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
33
surgical suite supplementary lighting
lighting the surgical suite
Fixtures designed for use in surgical suites must satisfy a large
number of demanding lighting and environmental requirements.
Kenall’s response to this critical need is MedMaster™ – a
family of fixtures designed to meet the specialized demands
of many of the most challenging healthcare applications.
THE THREE ZONES
Surgical suites are comprised of three zones: the immediate
surgical area, the secondary surgical area (used for surgical
preparation and clean up), and the perimeter area. While the
immediate surgical area’s specialized lighting instruments are
often selected by the surgeons themselves, the facility design
team specifies the supplementary fixtures that illuminate the
other two zones. That’s where MedMaster comes in.
STATE-OF-THE-ART ILLUMINATION
MEDMASTER™: The new standard in supplementary
operating room lighting.
A NEW BENCHMARK FOR
ENVIRONMENTAL PERFORMANCE
Supplementary surgical suite fixtures need to provide more
than quality illumination – they’re also key to maintaining an
operating room’s environmental integrity. This means being
toxin free, corrosion resistant, and able to withstand some of
the most aggressive cleaning protocols imaginable. They must
keep contaminants out of both the fixture and the operating
room itself while preventing electromagnetic interference from
affecting critical surgical and life support equipment.
MedMaster surgical fixtures not only meet or exceed the
toughest standards in existence for each of these performance
areas, they’re also the first of their type to give surgical teams
the dimming capabilities they want but haven’t been able to
get because of electromagnetic interference (EMI) issues. And
MedMaster surgical fixtures have even been verified to prevent
leakage in pressurized surgical environments (NSF49).
Optical systems designed specifically for surgical applications
allow MedMaster to easily meet the latest IES illuminance and
contrast ratio recommendations, providing surgical teams with
high quality, evenly distributed illumination that allows them to
perform their tasks effectively and comfortably.
4
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
surgical suites: PERFORMANCE REQUIREMENTS
PERFORMANCE REQUIREMENTS
PROVIDE HIGH ILLUMINANCE LEVELS FOR ZONES 2 & 3
To be effective, supplementary surgical suite lighting needs
to meet a number of key performance requirements, including
the ability to:
Kenall’s supplementary operating room lighting systems are not
only able to produce the high illuminance levels recommended
for Zones 2 and 3, they provide the dimming capability long
desired by surgical personnel – a capability precluded until now
by EMI-based concerns that necessitated the use of far less
effective three-step ballasts for illuminance control.
MAXIMIZE LIGHTING UNIFORMITY between zones
All surgical operations occur in one of three zones –
(1) the immediate surgical area,
(2) secondary surgical area, or
(3) perimeter of the room.
The most current IES Recommended Practice (RP-29-06)
for hospital lighting states the need for minimal luminance
contrast between zones to allow surgical teams to work
effectively and in maximum comfort for extended time periods.
MedMaster™ supplementary operating room luminaires
feature optical systems designed to achieve maximum
luminance uniformity between all three zones.
Maintain safe levels of radiated and conducted
emissions when equipped with electronic or
dimming systems
Lighting equipment must not produce emissions that interfere
with the performance of other equipment in the operating room.
For many years, military (MIL) standards have been utilized
to identify dangerous electromagnetic interference (EMI) and
develop testing criteria.
Professional EMI interpretation conducted by a certified,
independent test laboratory is necessary to ensure appropriate
and unbiased application of MIL standards for fixtures to be
used in operating room settings.
Average
Zone footcandles
1
200–300
2
100–125
3
40–60
3 2
1
2
3
The chart above shows the average maintained footcandle levels for
each surgical zone.
Kenall’s MedMaster™ Supplementary Operating Room Lighting
Systems have been tested by EMI professionals and found
to be in compliance with MIL Standard 461E. In addition,
MedMaster surgical systems meet the tough European
Certification (CE) standards, including IEC60590, that
specifically address electrical devices used in operating rooms.
MedMaster surgical lighting systems meet MIL and CE
standards for:
• Conducted Emissions • Radiated Emissions
• Harmonic Fluctuations • Voltage Fluctuations
mil std 461E (air force/navy fixed)
radiated emissions limits testing
Patent-pending Kenall MedMaster™ M2SE series 2' × 4' fixture
with SureShield™ stainless steel mesh filter:
60
A MP LI T UD E (d BuV/m )
50
T hr es ho ld
40
30
20
10
0
1. 0M
10. 0M
F R E QU E N C Y ( H z)
100M
Fixture tested by DLS Electronic Systems with F32T8 lamps and
electronic dimming ballasts operates within safe frequency levels.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
55
surgical suites: PERFORMANCE REQUIREMENTS
PROVIDE IMMUNITY TO DANGEROUS RADIATED AND
CONDUCTED EMISSIONS
CREATE A leak-proof BARRIER BETWEEN THE
PLENUM AND OPERATING ROOM
MedMaster™ surgical systems have been independently
tested and verified to meet CE performance criteria with
Kenall's patented SureShield™ stainless steel mesh screen for
the following areas of immunity:
MedMaster's internal components are isolated from
the surrounding environment. This isolation protects the
environment from heat, sparks, arcing, dirt, dust, moisture,
air pressure differences, and other conditions that would
adversely affect processes or safety in the room. In fact, every
MedMaster surgical lighting system carries the UL IP65 rating
– a rating that proves the fixture’s dust-tight performance and
water jet protection.
• Voltage dips, interruptions, and variations
• Radiated 60Hz magnetic fields from power lines,
transformers, and motors
• Electrical fast transient arcing of contacts on nearby
power and signal lines
• Surge voltage from lightning
• Radiated electromagnetic fields from walkie-talkies
and commercial radio station broadcasts
• Electrostatic discharge
• Conducted radio frequency
BE TOXIN FREE, CORROSION RESISTANT,
AND EASY TO CLEAN
Cold rolled steel housings, 1,000-hour salt spray tested antimicrobial finishes, stainless steel fasteners, hole-free seam
welded construction, and smooth exterior lenses make
MedMaster operating room lighting fixtures toxin free, easy to
clean, and corrosion resistant. In addition, Kenall’s MedMaster
surgical fixtures have earned the National Sanitation
Foundation’s (NSF) listing for use in “Splash Non-Food Zones”
– a listing highly applicable to operating room environments
for cleanability.
Testing conducted by DLS Electronic Systems
6
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
featured product: medmaster™ supplementary surgical suite fixture
Supplementary Surgical Suite Fixture
Series M2SE
Ceiling Mount
Nominal 1' × 4', 2' × 2', 2' × 4'
Housing
Lens Frame
Listings
•One-piece, seam welded housing
continuously sealed to one-piece,
seam welded housing flange
• Sealed adjustable swing-out arms
(flange-mounted version only)
• SureShield™ stainless steel mesh
screen (to restrict radiated EMI)
• One-piece, cold rolled steel with
continuous lens frame gasket ledge
and gap-free non-porous closed cell
gasketing
•Lens frame secured with aircraft
cables and stainless steel flat head
fasteners
•UL and CUL Wet Location
•UL Classified IP65
• MIL-STD-461E – Air Force/Navy Fixed
•NSF2 – Splash Non-Food Zone
•NSF49 – Pressurized Leakage Test
• Patents Pending
Finish
optical system
• Standard anti-microbial finish
• 1,000-hour salt spray tested
•Field directable reflectors
•Asymmetrical reflector design (for
superior optical control)
• Smooth, easy to clean exterior surface
•Green phosphor lamp option
5
22 7/8"
48 3/8"
22 7/8"
97 /8"
147 "
3" minimum
m2se example fixture configurations & recommended ceiling cutouts
Row configuration
l-configuration
48 3/8"
22 7/8"
22 7/8"
97 5/8"
147 "
3" minimum
square configurationjoiner band detail
22 7/8"
3" minimum
48 3/8"
1"
225/8"
97 5/8"
97 5/8"
111/64""
The joiner band maintains the
integrity of the seal between
the room and the plenum when
row mounting fixtures. Included
when specifying row mounted
applications.
5"
22 7/8"
3" minimum
3" minimum
5
48 3/8" 97 /8"
22 7/8"
3" minimum
1"
225/8"
97 5/8"
97 5/8"
/64""
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 1FAX
847-360-1781 www.kenall.com
11
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
5"
77
featured product: medmaster™ downlight series
medmaster™ Downlight
Series M2DL
Ceiling Mount
Nominal 6" and 8" Aperture
HOUSING
optical system
Listings
•Aluminum housing with seam
welded corners
•Available in vertically or horizontally
lamped housings
• Cold rolled steel trim secured by
captive stainless steel flat head
fasteners
•Aluminum reflector with low iridescent
anodized finish
• Smooth, easy to clean exterior lens
surface
•Lens sealed to trim with continuous
lens retention system
•Available with LED and compact
fluorescent (with dimming option), or
incandescent lamp sources
•UL and CUL Listed for Through Branch
Circuit Wiring
•UL and CUL Wet Location
•UL Classified IP65
• MIL-STD-461E 461E – Air Force/
Navy Fixed
•NSF2 – Splash Non-Food Zone
•NSF49 – Pressurized Leakage Test
Finish
• Standard anti-microbial finish
• 1,000-hour salt spray tested
8
OPTIONS
• Single wallwash light distribution
• Black baffle
Distribution Patterns
Reflector Finishes
Standard Round
Clear Specular
Wall Wash
Champagne Gold
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
STAT AREA
Zone 1 @ 3' AFF
Zone 2 @ 3' AFF
Zone 3 @ 3' AFF
AVG
FC
212
165
77
MAX
FC
213
210
122
Zone 1 Immediate surgical area
Zone 2 Secondary surgical area
Zone 3 Perimeter of the room
MIN
FC
211
94
41
AVG/
MIN
1.0:1
2.0:1
1.9:1
IES
Recommended FC
Zone 1
200–300
Zone 2
100–125
Zone 3
40–60
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
53
47
45
45
42
84
49
94
13
8
14
0
14
2
14
2
14
0
13
8
12
7
11
0
94
62
15
5
15
7
15
7
15
7
15
7
15
5
14
2
12
2
10
5
10
9
12
7
57
10
5
12
2
14
2
94
84
94
85
73
91
84
78
67
78
73
68
78
66
86
72
61
10
7
95
83
69
58
52
48
78
66
56
50
46
18
0
18
2
18
2
18
2
18
2
18
0
16
4
14
0
11
9
50
54
61
72
86
11
1
99
91
76
64
51
55
62
74
52
56
64
76
11 11
4
7
10 10
2
5
88 91
19
9
20
3
20
3
20
3
20
3
19
9
18
0
15
3
13
0
10 10
2
5
11 11
4
7
12
13
7
0
14 15
9
2
17 18
5
0
88
74
62
18 19
8
4
19 19
1
7
19 19
1
7
19 19
1
7
19 19
1
7
18 19
8
4
17 17
1
6
14 14
6
9
12 12
4
7
10
0
10 11
7
1
11 12
9
4
14 14
0 5
16 17
3 1
95
83
69
58
10
1
90
16
8
17
1
17
0
17
1
17
1
16
8
15
4
13
2
11
2
10
1
11
3
13
2
15
4
56
MAX/
MIN
1.0:1
2.0:1
3.0:1
94
10 10 10 10
9
9
9
9
12 12 12 12
1
2
1
1
13 13 13 13
5
5
5
5
15 15 15 15
8
9
8
7
18 18 18 18
7
8
7
6
10
8
12
0
13
4
15
6
18
5
79
67
59
55
78
66
58
55
53
57
65
77
55
59
67
79
56
60
67
80
57
60
67
79
20
7
18
8
15
9
13
5
12 12 12 12
1
2
1
1
10 10 10 10
9
9
9
9
94 94 95 95
20
8
18
8
15
9
13
5
12
0
10
8
94
11
8
10
6
92
20
7
18
7
15
8
13
5
20
6
18
6
15
8
13
5
20
7
21
2
21
3
21
3
21
2
20
5
18
5
15
7
13
4
20
8
21
2
21
3
21
3
21
3
20
2
18
3
15
5
13
2
20
7
21
1
21
2
21
2
21
1
95
20
6
21
1
21
1
21
1
21
1
95
79
20
5
20
9
20
9
20
9
20
9
94
80
67
94
79
67
79
67
67
78
57
59
66
55
59
20
2
20
6
20
7
20
7
20
6
10
6
11
8
13
2
15
5
18
3
92
77
65
55
59
55
59
94
79
67
55
59
94
79
67
55
59
20
7
18
7
15
8
13
5
20
7
21
1
21
2
21
2
21
1
20
6
20
6
18
6
15
8
13
5
21
1
21
1
21
1
21
1
92
77
65
53
57
56
60
67
80
55
59
67
79
55
59
67
79
10
5
11
7
13
1
15
3
18
0
91
76
64
52
56
10
2
11
4
12
7
14
9
17
6
88
74
62
51
55
55
59
66
78
53
57
65
77
52
56
64
51
55
62
74
10
2
89
10
5
91
76
11
4
11
7
20 20 19 19
2
9
4
5
20 20 20 19
7
3
8
9
21 20 20 19
7
3
8
0
21 20 20 19
7
3
8
0
20 20 20 19
7
3
8
9
20 20 19 19
2
9
4
5
18 18 18 17
1
6
5 3
15 15 15 14
3
9
7 5
13 13 13 12
4 2
1
7
10 10
8
6
12 11
0 9
13 13
2
4
15 15
5
7
18 18
3
5
94
78
66
54
58
12 12 12 12 11
2
1
1
0 9
11 10 10 10 10
0
9
9
8 6
95 95 95
94 92
20
8
18
8
15
9
13
6
20
8
21
2
21
3
21
3
21
3
10 10 10
9
9
9
12 12 12
2
1
1
13 13 13
6
5
5
15 15 15
9
8
8
18 18 18
8
7
6
95
80
67
55
59
83
69
58
48
52
50
54
61
72
10
0
86
11
2
18
9
19
2
19
2
19
2
19
2
18
9
17
2
14
6
12
5
48
52
59
69
83
96
10
7
18
1
18
3
18
3
18
3
18
3
18
1
16
5
14
1
12
0
10 96
0
11 10
1
7
12 12
5
0
14 14
6
1
17 16
2
5
86
72
61
50
53
46
50
56
66
79
10
2
91
17
0
17
3
17
2
17
2
17
3
17
0
15
6
13
3
11
4
10
2
11
4
13
3
15
6
91
79
66
56
46
50
85
78
67
57
49
41
45
45
47
53
62
73
85
94
15
7
15
9
15
9
15
9
15
9
15
7
14
4
12
4
10
6
41
45
49
57
68
78
85
14
0
14
2
14
3
14
3
14
2
13
9
12
9
11
1
95
10 95
6
12 11
4 1
14 12
4 9
94
85
73
62
53
45
47
typical surgical suite 2
26' × 25' Area, 9' Mounting Height
90/60/20 Room Reflectance, 0.80 LLF (Source: IESNA RP-29-06)
Catalog No. M2SEFI24-4-F32T8
54
58
Zone 1 Immediate surgical area
Zone 2 Secondary surgical area
Zone 3 Perimeter of the room
62
53
57
55
60
63
67
72
79
84
10
8
11
4
11
9
12
1
11
9
11
6
11
2
10
4
93
10
2
93
82
74
70
66
62
59
52
57
60
63
67
72
78
85
93
12
1
12
8
13
3
13
5
13
5
13
1
12
4
11
4
10
3
10
1
11
2
90
81
75
70
66
63
56
59
61
65
70
76
82
10
0
90
13
2
14
0
14
5
14
8
14
8
14
4
13
5
12
4
11
0
10
7
10
7
95
85
79
74
69
65
58
61
62
67
72
79
87
10
7
96
14
6
15
5
16
1
16
4
16
4
16
0
14
9
13
5
11
9
10
2
11
7
13
2
92
84
78
72
67
59
63
MAX/
MIN
1.0:1
3.0:1
2.7:1
53
52
56
AVG/
MIN
1.0:1
2.0:1
1.7:1
57
51
55
MIN
FC
233
85
51
49
50
53
MAX
FC
244
247
135
48
52
AVG
FC
237
174
88
46
50
STAT AREA
Zone 1 @ 3' AFF
Zone 2 @ 3' AFF
Zone 3 @ 3' AFF
45
47
64
69
75
83
11
7
10
4
93
16
6
17
7
18
4
18
8
18
8
18
3
17
0
15
2
13
2
11
2
13
0
14
9
99
90
83
76
70
60
65
23
4
21
6
19
0
16
3
21
3
22
7
23
5
24
0
24
0
10
8
12
0
13
7
16
1
19
0
97
87
78
66
71
22
3
23
5
24
2
24
6
24
7
24
1
22
3
19
5
16
7
10
4
11
5
12
7
14
4
17
0
20
0
92
82
70
75
24
2
22
4
19
6
16
8
22
8
23
8
24
3
24
6
24
7
10
9
12
1
13
3
15
0
17
6
20
6
97
86
73
78
24
0
22
3
19
3
16
6
23
0
23
7
23
7
24
3
24
4
11
2
12
5
13
7
15
3
17
9
20
9
99
87
74
79
67
72
79
89
70
77
85
96
74
80
77
83
77
83
10 10 10
5
1 4
89 91 92
13 14 14 149 14
1 3 7
9
11 12 13 13 13
4 5 0 3
4
10 11 11 11 12
1 0 5 9
0
19
2
20
4
21
3
21
7
21
7
21
2
19
6
17
3
14
9
10
9
12
4
14
6
17
0
98
89
80
73
63
67
76
82
10
3
91
14
7
13
2
11
8
23
6
21
8
19
0
16
3
23
0
23
5
23
7
23
9
23
9
12
6
13
9
15
5
18
0
21
0
14
10
0
88
74
80
75
81
10
2
90
14
1
13
1
11
7
23
2
21
5
18
6
16
0
22
9
23
4
23
4
23
5
23
5
11
5
12
8
14
0
15
6
18
1
21
0
10
1
88
74
80
91
76
82
23
0
21
2
18
2
15
7
23
2
23
6
23
5
23
5
23
4
11
7
13
1
14
4
15
9
18
4
21
4
76
80
75
81
10 10
1
1
89 89
14 14
2
1
12 12
8
8
11 11
5
5
23
0
21
2
18
3
15
7
22
9
23
3
23
3
23
3
23
3
11
5
12
8
14
1
15
6
18
1
21
1
10 10
1
3
89
76
80
75
81
10
0
89
13
9
12
6
11
4
23
0
21
1
18
1
15
5
23
8
23
9
23
9
23
7
23
5
11
9
13
2
14
6
16
2
18
8
21
7
10
4
92
77
83
91
76
82
75
80
88
99
13
8
12
4
11
2
23
1
21
1
18
1
15
4
24
4
24
3
24
1
23
8
24
0
73
78
85
96
10
9
12
4
14
1
16
1
18
8
21
5
95
84
69
75
10
0
11
3
12
8
14
7
17
1
19
4
88
79
66
72
69
74
81
91
65
70
77
86
10
7
96
12
1
63
67
72
80
88
97
11
0
24 23 21
1
3
0
24 24 21
7
0
6
24 23 21
6
9
6
24 23 21
2
5
2
23 22 20
6
7
4
22 21 19
4
4
2
20 19 17
2 1
1
17 16 14
7
2 3
14 13 12
5 7
5
11
4
13
0
14
6
16
6
19
3
22
2
99
88
73
79
13 12
4 8
12 11
0 4
10 10
8
3
24
2
24
7
24
6
24
3
23
8
22
9
20
8
17
8
15
1
12 11
0 8
13 13
4 3
14 14
8
8
16 16
5
7
19 19
2
4
22 22
1
3
10 10
5 3
92
77
83
86
79
72
62
67
60
65
70
75
82
89
10
0
18
2
18
7
18
6
18
3
17
7
16
7
15
0
13
1
11
3
59
63
67
72
77
83
92
15
9
16
4
16
3
16
0
15
5
14
7
13
3
11
8
10
3
10 95
3
11 10
6
5
13 11
1
8
15 13
0
4
16 14
9
9
92
83
75
64
69
57
61
65
69
73
78
87
14
3
14
8
14
8
14
5
14
0
13
2
12
1
10
8
96
11
0
12
3
13
5
98
89
82
75
70
60
65
83
78
71
66
61
53
58
80
56
58
61
65
69
74
51
55
57
60
64
69
73
88
80
11
4
11
7
11
9
11
7
11
2
10
6
10
1
90
12
9
13
3
13
3
13
1
12
6
11
9
11
0
99
10 91
1
11 10
3 1
12 11
2 0
91
83
77
71
66
59
62
typical surgical suite 1
26' × 25' Area, 9' Mounting Height
90/60/20 Room Reflectance, 0.80 LLF (Source: IESNA RP-29-06)
Catalog Nos. M2SEFI24-4-F32T8, M2DL6HF-1-32P
41
45
surgical suites: photometrics & layouts
4-lamp system typical layouts
IES
M2SE/M2DL Avg.
Recommended FC
FC Produced
Zone 1
200–300
237
Zone 2
100–125
174
Zone 3
40–60
88
The chart above shows the average maintained footcandle levels
for each surgical zone.
M2SE Avg.
FC Produced
212
165
77
The chart above shows the average maintained footcandle levels
for each surgical zone.
99
STAT AREA
Zone 1 @ 3' AFF
Zone 2 @ 3' AFF
Zone 3 @ 3' AFF
10
AVG
FC
285
248
106
MAX
FC
293
305
212
Zone 1 Immediate surgical area
Zone 2 Secondary surgical area
Zone 3 Perimeter of the room
MIN
FC
276
147
50
AVG/
MIN
1.0:1
2.0:1
2.0:1
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
94
11
7
14
4
16
9
19
0
20
1
20
2
19
4
18
7
18
7
19
4
20
2
20
1
19
0
16
9
14
4
11
6
93
77
65
57
54
85
10
5
12
6
14
7
16
5
17
5
17
4
16
8
16
4
16
4
16
8
17
4
17
5
16
5
14
7
12
6
10
5
85
71
60
54
50
10
8
13
8
17
5
20
7
23
4
24
8
10
1
12
8
16
1
18
9
21
3
22
6
IES
Recommended FC
Zone 1
200–300
Zone 2
100–125
Zone 3
40–60
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
M2SE Avg.
FC Produced
285
248
106
56
60
69
83
10
0
82
10
2
83
29
5
28
3
26
9
26
9
28
2
29
5
29
4
27
6
24
5
10
3
84
30
2
29
0
27
7
27
6
29
0
30
2
30
0
28
3
25
1
29
9
29
8
28
0
24
8
30
3
30
2
28
4
25
2
30
3
29
1
27
8
27
8
29
1
12 12
8
8
16 16
4
5
21 21
0
0
25 25
2
1
28 28
4
3
30 30
2
1
10
3
84
29
9
28
7
27
4
27
4
28
7
12 12 12
2
4
7
15 16 16
6
0
3
20 20
20
0
4
8
24
24 24
0
5
9
27 27 28
1
6
1
28 29 29
7
4
8
98
80
27 28
9
9
26 27
7
6
25 26
4
3
25 26
4
3
26 27
7
6
27 28
8
9
27 28
7
7
26 27
1
0
23 23
1
9
11
8
15
1
19
3
23
1
26
1
27
7
95
78
30
5
30
3
28
5
25
3
30
5
29
3
27
9
27
9
29
2
85
67
73
30
4
30
3
28
5
25
3
30
5
29
2
27
9
27
9
29
2
10
3
84
66
72
30
3
29
1
27
8
27
7
29
1
30
3
30
2
28
4
25
1
30
5
30
3
28
5
25
3
30
2
30
0
28
3
25
1
29
0
27
6
27
6
28
9
30
2
12 12
8
8
16 16
4
4
21 21
0
0
25 25
2
1
28 28
4
3
30 30
2
1
10
3
84
67
72
30
5
29
3
27
9
27
9
29
2
12
9
16
6
21
2
25
3
28
6
30
3
10 10
3 4
85
69
73
12 12
9
9
16 16
6
5
21 21
2
1
25 25
3
3
28 28
6
5
30 30
3
3
10
4
85
67
73
92
75
65
60
87
72
62
57
61
66
77
95
63
68
80
98
64
69
81
99
65
71
10
1
83
66
71
10
2
83
66
71
10
2
83
67
72
10
4
84
68
72
67
72
10 10
3 4
84 84
66
71
10
2
83
66
71
10
2
83
92
76
60
65
65
71
10
1
83
64
69
81
99
63
68
80
61
66
77
94
15
1
11
7
15
6
12
1
98
19
3
20
0
59
64
75
91
14
5
11
3
18
5
26
7
25
5
24
4
24
4
25
5
26
7
26
6
25
0
22
2
95
78
62
67
29 29 28 27
5
9
8
9
28 28 27 26
2
6
6
7
27 26 26 25
9
3
4
4
27 26 26 25
9
3
4
4
28 28 27 26
2
6
6
7
29 29 28 27
5
9
8
9
29 29 28 27
7
7
8 4
28 27 27 26
1
1
0 6
24 24 23 23
8 4
9
1
12
2
15
6
20
0
24
0
27
1
28
8
98
80
63
68
11
4
14
5
18
5
22
2
25
0
26
6
12
4
16
0
20
4
24
5
27
6
29
4
10
0
82
64
70
11
8
15
1
19
3
23
1
26
1
27
7
12
7
16
2
20
8
24
9
28
1
29
8
10
2
83
66
71
18 19 20 20 20 20 21 21 21 21 21 20 20 20
6
3
0
4
0
2
0
1
1 1
9
9
7 4
14 15 15 15 16 16 16 16 16 16 16 16 16 15
6
1
6
9
2
4
4
5
5 5
4
4
2 9
11 11 12 12 12 12 12 12 12 12 12 12
12 12
4
7
2
4
6
8
8
9
8 9
8
7
6
4
26
7
25
5
24
4
24
4
25
5
26
7
26
5
25
0
22
1
11
4
14
6
18
6
22
2
25
0
26
6
92
76
67
72
57
62
72
87
13
7
10
7
17
4
24
9
23
9
22
9
22
9
23
9
24
9
24
8
23
4
20
7
10
8
13
7
17
4
20
8
23
4
24
8
87
72
58
62
55
60
69
82
16
0
12
7
10
0
22
7
21
8
21
0
21
0
21
8
22
7
22
7
21
4
19
0
10
1
12
7
16
0
19
0
21
4
22
7
82
69
56
60
17
4
16
7
16
2
16
2
16
7
17
4
17
5
16
5
14
7
10
4
12
5
14
7
16
5
17
5
84
70
60
50
54
54
57
64
76
50
53
59
69
14 12
3 5
11 10
5 4
92 84
20
2
19
4
18
7
18
7
19
4
20
2
20
2
19
1
17
0
11
6
14
3
17
0
19
1
20
2
93
77
65
54
57
IES
Recommended FC
Zone 1
200–300
Zone 2
100–125
Zone 3
40–60
16 17
0 5
12 13
8 8
10 10
8
1
24
9
23
8
22
9
22
9
23
8
24
9
24
8
23
4
20
7
88
22
7
21
8
20
9
20
9
21
8
22
6
22
6
21
3
18
9
73
MAX/
MIN
1.0:1
2.0:1
4.0:1
83
66
72
typical surgical suite 2
26' × 25' Area, 9' Mounting Height
90/60/20 Room Reflectance, .8 LLF (Source: IESNA RP-29-06
Catalog No. M2SEFI24-6-F32T8
70
66
71
Zone 1 Immediate surgical area
Zone 2 Secondary surgical area
Zone 3 Perimeter of the room
77
64
70
66
77
91
10
9
13
0
15
3
17
4
19
2
20
6
21
6
22
1
22
1
21
4
20
1
18
1
15
5
71
84
95
11
1
13
0
14
6
15
8
16
9
17
9
18
2
18
0
17
4
16
6
15
1
13
0
50
54
59
68
80
54
57
64
74
13
0
10
8
89
58
54
61
11
1
96
51
53
47
51
77
92
11
4
14
1
17
3
20
5
23
4
71
84
10
2
12
3
14
9
17
7
20
2
56
61
69
81
95
78
62
67
98
80
64
69
31
1
31
3
31
0
31
3
32
3
32
7
31
8
29
2
25
4
10
0
81
65
70
30
5
29
7
28
7
28
8
30
0
31
0
30
6
28
6
25
2
31
5
31
0
28
8
25
3
30
7
30
4
28
5
25
2
30
5
29
5
28
3
28
4
29
6
12 12
4
4
15 16
9
0
20 20
4
2
24 24
6
4
27 28
0
8
30 30
0
0
99
81
64
70
30
7
30
2
29
4
29
6
20
8
11 11 12
3
8
1
14 15 15
5
1
6
18 19
19
5
2
9
22
23 24
6
4
0
26 27 27
4
0
5
29 29 29
4
8
8
92
76
61
66
30 31
5
3
31 32
7
1
32 32
3
3
33 32
0
8
33 33
6
6
33 33
4
7
31 32
7
3
28 29
6
4
24 25
5
4
10
7
13
6
17
2
21
2
25
0
28
2
87
73
59
63
30
4
30
2
28
3
25
0
30
3
29
2
27
9
28
0
29
2
83
66
71
30
2
30
0
28
1
24
9
30
2
29
0
27
7
27
7
29
0
10
2
83
66
71
30
7
29
6
28
3
28
2
29
4
30
4
30
0
28
1
24
8
30
3
30
0
28
2
24
9
30
5
30
0
28
0
24
6
30
0
28
8
28
7
29
7
31
0
12 12
6
7
16 16
2
3
20 20
7
8
24 25
9
0
28 28
3
5
30 30
3
6
10
1
82
65
71
30
4
29
2
28
0
27
9
29
2
12
6
16
2
20
7
24
8
28
2
30
1
10 10
1 2
82
67
71
12 12
6
5
16 16
1
1
20 20
5
6
24 24
7
7
28 28
0
0
30 29
0
9
10
1
82
65
71
93
76
66
61
73
63
59
63
68
79
96
64
69
81
99
64
70
10
0
82
65
71
10
2
83
65
71
10
2
83
65
70
10
1
82
65
70
10
1
82
66
70
65
70
10 10
0 0
82 82
64
69
81
99
64
69
80
99
93
77
61
66
63
68
79
97
61
66
77
94
60
65
75
91
58
62
72
86
17
5
13
5
10
6
18
7
14
4
11
3
56
60
69
82
12
5
99
16
1
32
0
32
5
32
1
31
4
30
5
28
9
26
4
23
3
19
6
96
79
63
68
31 32 33 33
7
6
3
5
30 32 33 33
2
5
5
7
29 31 32 32
2
7
9
6
29 30 32 32
9
2
3
3
30 31 32 31
2
0
7
1
30 31 31 30
1
4
5
6
29 29 29 28
6
3
8 9
27 27 26 25
6
2
6 2
24 23 22 21
2 6
8
4
12
4
16
1
20
6
25
1
29
2
32
2
10
0
81
64
70
11
5
14
7
18
7
22
9
26
9
30
0
12
6
16
2
20
7
25
2
29
0
31
6
10
1
82
65
70
12
0
15
5
19
8
24
3
28
4
31
5
12
7
16
3
20
7
25
0
28
6
30
8
10
2
83
66
71
18 20 20 21 21 21 21 20 20 20 20 20 20 19
9
1
9
0
7
0
0
9
8 8
5
1
1 5
14 15 16 16 16 16 16 16 16 16 15 15 15 15
7
5
1
2
3
3
2
2
1 1
9
8
5 0
11 12 12 12 12 12 12 12 12 12 12 12
12 11
6
0
4
5
6
7
6
6
5 5
4
3
1
7
28
8
30
4
31
4
32
1
32
5
32
0
30
1
27
1
23
1
10
0
12
6
15
8
19
4
23
1
26
2
83
70
57
61
87
15 17
1 2
12 13
2 6
98 10
8
26
0
27
7
28
8
29
5
29
8
29
1
27
2
24
5
20
9
66
62
22
4
24
1
25
2
25
8
26
0
25
2
23
6
21
2
18
2
55
58
53
56
MAX/
MIN
1.0:1
3.0:1
5.0:1
65
63
69
AVG/
MIN
1.0:1
2.0:1
2.0:1
71
62
67
MIN
FC
277
123
46
61
60
65
MAX
FC
300
337
221
58
63
AVG
FC
288
264
101
56
61
STAT AREA
Zone 1 @ 3' AFF
Zone 2 @ 3' AFF
Zone 3 @ 3' AFF
55
58
54
57
65
76
11
3
91
14
4
29
1
29
8
29
5
28
8
27
9
26
1
23
6
20
7
17
4
10
7
13
5
16
9
20
7
24
3
27
2
87
73
59
64
51
55
61
70
12
6
10
1
83
25
3
26
1
25
9
25
3
24
3
22
6
20
4
17
9
15
1
12
1
14
9
18
1
21
1
23
6
98
81
69
57
61
17
2
17
7
18
0
17
6
16
7
15
6
14
4
12
8
10
9
10
9
12
8
14
9
16
4
94
78
66
58
50
54
50
52
57
64
75
46
49
53
59
69
10 93
7
90 81
21
2
21
9
21
9
21
4
20
4
19
0
17
1
15
1
12
8
10
6
12
9
15
4
17
9
19
9
87
73
63
55
57
typical surgical suite 1
26' × 25' Area, 9' Mounting Height
90/60/20 Room Reflectance, .8 LLF (Source: IESNA RP-29-06)
Catalog No. M2SEFI24-6-F32T8
51
55
surgical suites: photometrics & layouts
6-lamp system typical layouts
M2SE Avg.
FC Produced
288
264
101
PATIENT ROOM lighting
Patient rooms pose a difficult lighting specification challenge,
requiring attractive, durable, and economical systems capable
of multiple illumination functions. Kenall has developed a
system specifically designed to meet these challenges –
MedMaster™.
LIGHTING FOR DIFFERENT TASKS
HIGH PERFORMANCE ILLUMINATION
Patient rooms require different illumination for different
purposes, including ambient room lighting, light for patients
to read by, and lighting for examining patients. Kenall’s
MedMaster™ series includes task specific, or multi-function
ceiling and headwall fixtures. All MedMaster patient room
fixtures offer nightlight, nurse’s chart light, and grounded
receptacle options, in addition to a number of control choices.
MedMaster ceiling mounted ambient fixtures feature glarefree illumination, producing a comfortable residential feel.
For patient reading, uniform glare-free illumination levels are
standard. Kenall’s MedMaster series combines sound optical
design and the finest materials to produce superior photometric
performance, meeting IES RP-29-06 requirements for patient
room lighting.
Our MedMaster CleanScene™ lightbox series, designed to
create a pleasing patient room atmosphere, utilizes the highest
quality duratrans graphic images and features uniform graphic
panel luminance that eliminates unwanted lamp imaging.
THE FINEST QUALITY
Maintaining the Kenall tradition of quality, only the finest
materials are used to manufacture these fixtures. All
ceiling mounted units feature one-piece, seam welded
housings constructed of cold rolled steel painted with an antimicrobial polyester powder after fabrication. Wall mounted
units utilize a combination of extruded and die-cast aluminum
pieces, and include DR acrylic lenses for unsurpassed durability.
These materials make Kenall’s Patient Room fixtures the
highest quality of their type in healthcare lighting.
EASY TO CLEAN
Featuring standard anti-microbial polyester powder coating and
a 1,000-hour salt spray finish, these systems stand up to the
toughest cleaning protocols. Specify the IP65 ingress barrier
door – a seal against dust, dirt, and moisture – with any ceiling
mounted patient room fixture for even easier maintenance.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
11
11
medmaster™ patient room lighting product universe
multi-function Ceiling mount
• Multi-function/three compartment patient room luminaire –
ambient, exam, and reading.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
•Two or three function/single compartment luminaires –
ambient, exam, and reading (optional).
• Perforated metal with pearlescent acrylic diffuser for
ambient lighting (MPCAIE) or frosted prismatic refractor
shielding for direct patient exam lighting (MPCADE).
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number MPC
Description Medical Patient Ceiling
Nominal Size 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types 40, 50, 55W Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
Series Number MPCAIE
Description Medical Patient Ceiling Ambient Indirect Exam
Nominal Size 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types T5HO
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/ IB
Option, NSF2 (Splash Zone)
new options: LED Reading heads,
MPCAIE diffuser, & led nightlights
•Optional LED reading heads are now available on multifunction ceiling-mount products MPCAIE and MPCADE.
• The standard MPCAIE diffuser (perforated metal with
pearlescent acrylic) is now an available option with most
ceiling fixtures containing an ambient compartment.
•LED nightlights with brightness control (dimmable to 20%)
can be specified on most MedMaster™ patient room
lighting fixtures.
LED Reading Heads
(MPCAIE pictured)
LED Nightlight/
MPCAIE Diffuser
WATTAGE
LED Nightlight
3.6
LED Reading Heads 3.6
12
Series Number
MPCADE
Description Medical Patient Ceiling Ambient Direct Exam
Nominal Size
2' × 4'
Installation Types
Surface, Flange, Grid
Lamp Types
T8
Standard Listings
UL Damp Locations
Optional ListingsUL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
LUMENS
42-210
158
AVG LIFE
50K
50K
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™/residence™ patient room lighting product universe
multi-function/two function wall mount
•Flip-open, three function patient room luminaire –
ambient, reading, and procedural.
•High performance extruded linear 50% DR acrylic lens
with internal flutes.
•Approved by OSHPD for installation in seismic zones.
• Standard anti-microbial finish.
•Two function patient room valance luminaires –
ambient and reading.
•Available in traditional or contemporary styles.
•Lens features internal prisms and smooth exterior for even
illumination and ease of maintenance.
•Approved by OSHPD for installation in seismic zones.
• Standard anti-microbial finish.
Series Number MPWF (Flip open)
Description Medical Patient Wall Flip
Nominal Size 2', 3', 4'
Installation Types Surface
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations, meets OSHPD 2007
seismic loading standard
Series Number MPWT (Traditional)
Description Medical Patient Wall Traditional
Nominal Size 2', 3', 4'
Installation Types Surface
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations, meets OSHPD 2007
seismic loading standard
•Two function patient room luminaires – ambient and
reading (MPWUD), or non-partitioned indirect/direct
distribution (MWUD).
•High performance extruded linear 50% DR acrylic lens with
internal flutes and smooth exterior for easy cleaning.
•Approved by OSHPD for installation in seismic zones.
• Standard anti-microbial finish.
Series Number MPWC (Contemporary)
Description Medical Patient Wall Contemporary
Nominal Size 2', 3', 4'
Installation Types Surface
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations, meets OSHPD 2007
seismic loading standard
Series Number MPWUD (Non-flip open)
Description Medical Patient Wall Up/Down
Nominal Size 2', 3', 4'
Installation Types Surface
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations, meets OSHPD 2007
seismic loading standard
Series Number MWUD (Non-flip open, Non-partitioned)
Description Medical Wall Up/Down
Nominal Size 2', 3', 4'
Installation Types Surface
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations, meets OSHPD 2007
seismic loading standard
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
13
13
MedMaster™ patient room lighting product universe
two-function ceiling mount
14
• Classic two function/two compartment patient room
luminaire – ambient and exam.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
• Classic two function/two compartment patient room
luminaire – ambient and reading.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number MPCAE
Description Medical Patient Ceiling Ambient Exam
Nominal Size 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types 40, 50, 55W Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
Series Number MPC
Description Medical Patient Ceiling
Nominal Size 2' × 2'
Installation Types Surface, Flange, Grid
Lamp Types 36W Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ patient room lighting product universe
ambient ceiling mount
•Ambient patient room luminaires with one perforated metal
basket with pearlescent acrylic diffuser.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number MAC
Description Medical Ambient Ceiling
Nominal Size 2' × 2'
Installation Types Surface, Flange, Grid
Lamp Types 40, 50, 55W Biax
Standard Listings UL Damp Locations
Optional Listings:UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
Series Number MAC
Description Medical Ambient Ceiling
Nominal Size 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types T5HO
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
•Ambient patient room recessed downlights in 6" or 8" aperture
sizes and in vertically or horizontally lamped housings.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room.
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number
Description Nominal Size
Installation Types
Lamp Types
Standard Listings
MDL
Medical Downlight
6" or 8" apertures
Recessed
LED, CFL, Incandescent
UL/CUL listed for through branch circuit
wiring, UL Wet Locations, IP65, NSF49,
NSF2 (Splash Zone)
•Ambient patient room luminaires with one or two
perforated metal baskets and pearlescent acrylic diffusers.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room.
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number MAC2B
Description Medical Ambient Ceiling Two-Basket
Nominal Size 1' × 4'
Installation Types Surface, Flange, Grid
Lamp Types T8, T5, T5HO
Standard Listings UL Wet Locations, IP65, NSF49,
NSF2 (Splash Zone)
Series Number
Description Nominal Size
Installation Types
Lamp Types
Standard Listings
MAC2B
Medical Ambient Ceiling Two-Basket
2' × 2'
Surface, Flange, Grid
40, 50, 55W Biax, T8, T5HO
UL Wet Locations, IP65, NSF49,
NSF2 (Splash Zone)
Series Number MAC2B
Description Medical Ambient Ceiling Two-Basket
Nominal Size 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types T8, T5, T5HO
Standard Listings UL Wet Locations, IP65, NSF49,
NSF2 (Splash Zone)
Series Number MADC
Description Medical Ambient Direct Ceiling
Nominal Size 2'x2' and 2' × 4'
Installation Types Surface, Flange, Grid
Lamp Types T5HO, Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/ IB
Option, NSF2 (Splash Zone)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
15
15
MedMaster™ patient room lighting product universe
exam ceiling mount
• Patient room luminaires. MEC22 is shielded by a semispecular aluminum parabolic louver. MEC8 and MEC12
contain one perforated aluminum basket with pearlescent
acrylic diffuser and semi-specular reflector. MEC8 and
MEC12 are mounted on either side of the bed and provide
asymmetric illumination.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room (when specified
with full length Ingress Barrier option).
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
• Quartz exam patient room luminaires available with
symmetric or asymmetric distribution.
• Certified against leakage into the fixture, as well as leakage
from the plenum into the patient room.
•NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number MEC
Description Medical Exam Ceiling
Nominal Size 2' × 2'
Installation Types Surface, Flange, Grid
Lamp Types 40, 50, 55W Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
Series Number
Description Nominal Size
Installation Types
Lamp Types
Standard Listings
MEC1212S
Medical Exam Ceiling 12"x12" Symmetric
1' × 1'
Surface, Flange, Grid
250W Tungsten Halogen
UL Damp Locations, NSF2 (Splash Zone)
Series Number
Description Nominal Size
Installation Types
Lamp Types
Standard Listings
MEC1212A
Medical Exam Ceiling 12"x12" Asymmetric
1' × 1'
Surface, Flange, Grid
250W Tungsten Halogen
UL Damp Locations, NSF2 (Splash Zone)
Series Number MEC
Description Medical Exam Ceiling
Nominal Size 8" × 48" or 8" × 60"
Installation Types Surface, Flange, Grid
Lamp Types T5, T5HO, Biax
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
Series Number MEC
Description Medical Exam Ceiling
Nominal Size 12" × 48"
Installation Types Surface, Flange, Grid
Lamp Types T8, T5, T5HO
Standard Listings UL Damp Locations
Optional Listings UL Wet Locations, IP65, NSF49 w/IB
Option, NSF2 (Splash Zone)
16
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ cleanscene™ patient room lighting
lightbox ceiling mount
• MedMaster™ CleanScene™ lightboxes for patient rooms.
•Uniform graphic panel luminance with dimming capability.
•UL Classified IP65. NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number CS
Description CleanScene
Nominal Size 2' × 2'
Installation Types
Surface, Flange, Grid
Lamp TypesT5, T5HO
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash Zone)
• MedMaster™ CleanScene™ lightbox with graphic
compartment flanked by asymmetric exam luminaires.
•One-person, quick electrical component servicing and
graphic image installation.
•Uniform graphic panel luminance with dimming capability.
6500K daylight-balanced LED color temperature (graphic
compartment only, when specified with LEDs).
•UL Classified IP65. NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number Description Nominal Size Installation Types Lamp Types Standard Listings CSMEC (w/Asymmetric exam)
CleanScene Medical Exam Ceiling
4' × 4'
Recessed Grid
Biax, T5HO (exam); T5, T5HO, LED (graphic)
UL Wet Locations, IP65, NSF2 (Splash Zone)
Series Number
CS
Description CleanScene
Nominal Size
2' × 4'
Installation Types
Surface, Flange, Grid
Lamp TypesT5, T5HO
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash Zone)
Series Number
CS
Description CleanScene
Nominal Size
4' × 4'
Installation Types
Surface, Flange, Grid
Lamp TypesT5, T5HO
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash Zone)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
17
17
softstep™ patient room lighting product universe
low wall mount steplights
• SoftStep™ wall mounted steplights for patient room,
corridor, and pathway lighting.
•Available with duplex outlet (MSLD) and for through-wall
applications (MSLT).
•Low-output LEDs available in white, red, blue, and amber.
High-output LED lumen package available in white.
•LED options include field-adjustable light output control.
Dimmable to 40%.
•Optional external lens with smooth exterior to assist in
infection control. Available in polycarbonate, acrylic, or
tempered glass.
• Standard anti-microbial finish with gloss white faceplate.
new technology:
4100k led steplights
Kenall SoftStep™ steplights employ the latest, most
advanced LED technology. These new generation, 4100k
white LEDs combine soft, pleasing pathway and corridor
lighting with the safety and convenience of traditional
LED sources.
Additional steplight options
Series Number Description Nominal Size Installation Types Lamp Types Standard Listings MSL
Medical Steplight
3" × 9"
Recessed
Twin Tube CFL, LED
UL Damp Locations
• Stainless steel faceplate
•Full face lens
•LEDs available in white, red, blue, and amber
18
Series Number Description Nominal Size Installation Types Lamp Types Standard Listings MSLD (Duplex outlet)
Medical Steplight Duplex
6" × 9"
Recessed
Twin Tube CFL, LED
UL Dry Locations
Series Number Description Nominal Size Installation Types Lamp Types Standard Listings MSLT (Through wall)
Medical Steplight Through-Wall
5" × 9"
Recessed
Twin Tube CFL, LED
UL Damp Locations
Low Output
LED Steplights
High Output
LED Steplights
WATTAGE
LUMENS
AVG LIFE
0.5
3-10
50K
1.0
6-20
50K
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
mri/imaging suite lighting
MRI and related imaging suites present a unique lighting
environment calling for fixtures that won’t interfere with
sensitive medical equipment.
CleanScene’s nature scenes make welcome additions to
imaging suites where patients often spend considerable
time looking at the ceiling while undergoing scans. These
soothing images create a serene ambiance that helps
patients focus on pleasant thoughts and experiences
instead of medical procedures.
The new 2'X2', 2’X4', and 4' X 4' LED versions of our
MedMaster™ CleanScene™ lightbox luminaires allow
for backlit images to be displayed in MRI/imaging suites
because their dimmable LED (6500K daylight-balanced)
sources and non-ferrous aluminum housings work in
harmony with these demanding environments.
Like all CleanScene series fixtures, CSMRI products are
easy to install, resistant to abuse, and protect against fixturerelated environmental contamination. The hinged lens frame
is removable by one person for quick servicing of electrical
components and graphic image changes. All CleanScene
lightboxes are UL IP65 listed and National Sanitation
Foundation Splash Zone certified (NSF2).
Working in perfect coordination with CleanScene lightboxes
are our new MedMaster MRI downlights. Ideal for the
perimeter of imaging suites, MedMaster downlights provide
effective and pleasing supplementary illumination.
MedMaster™ CleanScene™ LED Lightboxes
Series CSMRI
Ceiling Mount
Nominal 2' × 2', 2' × 4', 4' × 4'
Housing
Optical System
•One-piece, seam welded,
non-ferrous aluminum
housing continuously
sealed to a one-piece,
seam welded housing
flange
•Uniform graphic panel
luminance
• Smooth, easy to clean
exterior lens surface
Finish
• Standard antimicrobial
finish
• 1,000-hour salt spray
tested
Lens Frame
• One-person lens frame
removal for easy
installation and maintenance
•One-piece, continuous
lens frame gasket ledge
and gap-free, closed cell
silicone gasketing
•Non-ferrous aluminum lens
frame secured by internal
hinge and stainless steel
flat head fasteners
Listings
•UL and CUL Wet Location
•UL Classified IP65
• MIL-STD-461E 461E –
Air Force/Navy Fixed
•NSF2 – Splash
Non-Food Zone
• Independently tested for
MRI suitability
Additional Recommended Product
medmaster™ MRI downlight (Mridl)
Recessed Downlights
Nominal 6" or 8" Aperture
Constructed of 100% non-ferrous materials for MRI/imaging
suites. Ideal for perimeter applications. UL and CUL listed for
through branch circuit wiring. NSF certified for ease of
cleanability. Standard anti-microbial finish. The 22-watt LED
ring produces the approximate total lumen output equivalent
of an 18-watt CFL, while the 38-watt LED ring produces the
equivalent of a 32-watt CFL.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
19
19
MedMaster™ cleanscene™ configurations & graphic images
SELECTING YOUR GRAPHIC IMAGE
Kenall offers a number of top-quality graphic images for
CleanScene™ lightboxes. To select the graphic image for
your fixture(s):
1. Go to www.kenall.com, click on Medical, and go to Lightbox
Image Gallery to view the available images.
2. Based on your selected fixture size and number of fixtures
(see chart below for examples), find the matching configuration
code (C1, D3, etc.).
3. Select an image that matches the horizontal, vertical, or square
orientation of your graphic display. Many images can also be
cropped to fit.
4. Complete the CleanScene ordering information, found on pages
96-102. This will provide the information needed to configure and
size your selected image. Record your selected image’s order
number in the Image Selection box. Kenall CleanScene fixtures
ship with the image panels pre-installed.
FIXTURE CONFIGURATIONS
Image Samples
2' × 2' Fixtures
C1
C6
C2
C9
C4
2' × 4' Fixtures
D1H
D3
D1V
D4
D2
Configuration Size
Fixture Size Number of Nominal
Nominal
Fixtures
C1
2' × 2'
2' × 2'
1
C2
2' × 4'
2' × 2'
2
C4
4' × 4'
2' × 2'
4
C6
4' × 6'
2' × 2'
6
C9
6' × 6'
2' × 2'
9
D1H/D1V 2' × 4'
2' × 4'
1
D2
4' × 4'
2' × 4'
2
D3
4' × 6'
2' × 4'
3
D4
4' × 8'
2' × 4'
4
Consult factory for alternate configuration requests.
20
4' × 4' Fixtures
C4
or
D2
Note: CS 4' × 4' fixtures do not require a
configuration selection when completing the
ordering information. However, it is important to
select an image from www.kenall.com marked
for C4 or D2 usage.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ MRI/imaging suite lighting
ceiling mount
• MedMaster™ CleanScene™ LED lightboxes for MRI/
imaging rooms.
•Non-ferrous construction.
•Uniform graphic panel illumination with LED dimming
capability. 6500K daylight-balanced LED color temperature.
•Utilizes high quality duratrans graphic images.
•UL Classified IP65. NSF certified for ease of cleanability.
Standard anti-microbial finish.
• MedMaster™ MRI recessed downlights in 6" or 8" aperture
sizes and in vertically or horizontally lamped housings.
• 100% non-ferrous construction.
•UL and CUL listed for through branch circuit wiring.
•UL Classified IP65. NSF certified for ease of cleanability.
Standard anti-microbial finish.
Series Number CSMRI
Description CleanScene MRI
Nominal Size 2' × 2'
Installation Types
Recessed Grid
Lamp Types
LED
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash
Zone), MIL-STD-461E (Air Force/Navy Fixed), Independently tested for MRI suitability
Series Number
Description Nominal Size
Installation Types
Lamp Types
Standard Listings
MRIDL
MRI Downlight
6" or 8" apertures
Recessed
LED, Incandescent
UL/CUL listed for through branch circuit
wiring, UL Wet Locations, IP65, NSF49,
NSF2 (Splash Zone)
High quality graphic images
Series Number CSMRI
Description CleanScene MRI
Nominal Size 2' × 4'
Installation Types Recessed Grid
Lamp Types LED
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash
Zone), MIL-STD-461E (Air Force/Navy Fixed), Independently tested for MRI suitability
Kenall’s CleanScene LED lightboxes are offered with a wide
selection of the industry’s most attractive, highest quality
duratrans images. These high-resolution images are produced
using the best quality photographic process available for
backlit imaging. To browse through our catalog of available
images, visit our website at www.kenall.com, click on
Medical, and select Lightbox Image Gallery.
Series Number CSMRI
Description CleanScene MRI
Nominal Size 4' × 4'
Installation Types Recessed Grid
Lamp Types LED
Standard Listings
UL Wet Locations, IP65, NSF2 (Splash
Zone), MIL-STD-461E (Air Force/Navy Fixed), Independently tested for MRI suitability
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
21
21
healthcare undercabinet lighting
The Kenall Solution
Furniture-integrated linear task lighting is often the most
effective solution for situations where high quality task
illumination is needed. Yet, there has been a growing demand
for undercabinet task systems with greater versatility,
environmental integrity, and lighting quality – as well as
special performance features – than you’ll find in most
traditional linear task lighting products.
That’s why Kenall has developed Stratalume Connects™,
one of the most comprehensive and versatile families of high
performance undercabinet task lighting solutions available.
Stratalume Connects systems are available with features
and options that make them appropriate for virtually any
environment where high quality undercabinet task lighting is
needed. The extruded aluminum housings are tough enough for
the most demanding environments, yet still look right at home
mounted to fine custom millwork or high-end furniture systems.
22
Choose individual fixtures or continuous rows; shallow or deep
profiles; T5, T5HO, T8, biaxial, or LED sources . . . and solid
or wraparound fronts. Plus, Stratalume Connects has been
designed for easy installation and maintenance, with easy-toclean lenses that can be removed and reinstalled without tools.
Stratalume Connects systems feature marine grade extruded
aluminum housings, polycarbonate end caps, non-corrosive
hardware, and close-tolerance, 100% DR acrylic lenses
with smooth external surfaces. Stratalume Connects won’t
corrode or provide environments friendly to biological or
chemical contaminants. They’ll withstand the most aggressive
cleaning protocols and have even earned the tough NSF Splash
Non-Food Zone listing, making them the right choice for
applications from industrial kitchens to laboratory environments.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
STRATALUME CONNECTS™ Features
Series MAUC
Individual fixtures
continuous row configurations
One of the many features that make Kenall’s Stratalume
Connects™ systems so flexible is the ability to specify
individual fixtures or continuous rows.
Stratalume Connects™ fixtures have electrical and mechanical
interfaces that connect quickly and easily, and ensure that
continuous rows always have a clean, attractive appearance.
Solid Front
wraparound LENS
optical Lenses
quality end caps
Sharp cutoff distribution for
workstations and undercabinet installations.
Visible source luminance
creates brighter, more
appealing environments.
100% DR-acrylic lenses for
superior distribution and lamp
image diffusion.
Solid, interlocking end caps
prevent light leaks and hide
mounting hardware.
continuous row
connectivity
external
mounting feet
power connections
wiring modules
Fixtures interlock to create an
installer-friendly system.
External mounting feet allow
installation without accessing
internal compartments.
Molded interconnects and
power cords come in various
lengths for clean electrical
connections between fixtures.
Separate components house
switching, convenience
outlets, and motion sensors.
Extruded Housing Cross Section
with wraparound lens
Extruded Housing Cross Section
with Solid Front
Wraparound versions provide aesthetically pleasing, visually
comfortable source luminance...
...Solid front versions are designed to concentrate
illumination on the target area.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
23
23
STRATALUME™ Features
Series UC
SOLID FRONT
WRAPAROUND FRONT
Cutoff lighting ideal for
non-soffit cabinets.
Ideal under soffit cabinets
for task and surrounding
area lighting.
CONTINUOUS MOUNTING
LENS
Flush end design for
continuous, end-to-end
mounting.
Pliable, non-yellowing lens
material lies or snaps in
place for quick re-lamping.
OPTIONS
Available options include
cords and plugs, rocker
switches, and convenience
outlets.
LIGHTING IN A STAINLESS STEEL PACKAGE
For undercabinet and other linear task lighting applications
where high quality illumination and stainless steel
construction is required, Stratalume™ is a natural choice.
These discreet, high performance fixtures are perfectly
suited to a variety of academic and scientific facility
applications including study carrels, classrooms,
laboratories, and offices.
Stratalume fixtures may be ordered with either T5
or T8 lamping, and are also available with cold-rolled
steel housings.
24
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
suggested products for HOSPITAL EXTERIORS:
MILLENIUM™ Squares, ROUNDS, & OVALS
Millenium™ Squares, Rounds, and Ovals are available in an array of sizes
and shapes with a wide selection of lamp and ballast options, allowing use
of a consistent fixture design throughout the project.
Millenium’s proprietary optics deliver low-glare and high performance
illumination, while adding an attractive architectural detail to exteriors,
corridors, public spaces, and staff areas.
Plus, Millenium fixtures are incredibly durable and easy to maintain:
• UL IP64 certification means they’re impervious to dust and moisture,
keeping out bugs and dirt along with other contaminants and debris.
• Made with the finest materials and components available – from
marine-grade aluminum baseplates and U.V.-resistant polycarbonate
lenses to stainless steel fasteners and closed-cell gaskets -- Millenium
fixtures will look great for years to come.
• Millenium’s 1,000-hour salt spray-tested finish resists corrosion, making
these timeless fixtures appropriate for even the harshest environments.
• The most advanced lamps and ballasts placed in specially engineered
housings and optical chambers means internal components will require
less service and last longer.
In the unlikely event that something does go wrong with a Millenium
fixture, you’re protected by Kenall’s industry-leading Peace of Mind
Lifetime Guarantee™.
Compare Millenium’s quality, performance, versatility, and aesthetics to
any competing fixture series on the market and we’re sure you’ll agree
Millenium sets the standard.
Millenium™ Squares, Rounds, & OVALS – wall & ceiling mount
MS15FL/FSR/FD
MS15CL/CSR/CD
MR17EL/ESR/ED MR17BL/BSR/BD MR17CL/CSR/CD MR17FL/FSR/FD
MS11FL/FSR/FD
MS11CL/CSR/CD
MR13EL/ESR/ED MR13BL/BSR/BD MR13CL/CSR/CD MR13FL/FSR/FD
MS15EL/ESR/ED
MS15DL/DSR/DD
MO13EL/ED MO13BL/BD
MO13CL/CD
MO13FL/FD
MS11EL/ESR/ED
MS11DL/DSR/DD
MO13HL/HD
MO13HBL/HBD
MR17SP/RP
MR17NP/WP
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
25
25
suggested products for HOSPITAL EXTERIORS:
MILLENIUM freescale™
Millenium FreeScale™ meets the highest architectural standards for
design and materials while providing durability for permanence and
scalability for proportion and thematic consistency.
Many quality lighting fixtures are aesthetically pleasing but vulnerable
to breakage and corrosion. Millenium FreeScale, on the other hand,
combines classic design with the ability to endure significant physical
and environmental abuse.
FreeScale’s non-corrosive construction makes it ideal for exterior wall
and overhead applications. All FreeScale models feature 100% DR acrylic
lenses and marine-grade aluminum housings, baseplates, and lens frames.
They’re UL listed for wet locations and IP65 certified for protection from
moisture, dirt, bugs, and other unsightly debris.
FreeScale’s architectural shapes and wide selection of sizes gives the
specifier a visually consistent and appropriately proportioned lighting
element that can be used almost anywhere. Plus, a variety of bar
configurations and custom finishes allow you to tailor each fixture
to its specific aesthetic context.
Millenium Freescale™ – wall & ceiling mount
FS512R/T
FS812R/T
FS1212R/T
FS518R/T
FS818R/T
FS1218R/T
FS524R/T
FS824R/T
FS1224R/T
26
FS548R/T
FS848R/T
FS1248R/T
FS1212P/PD
FS1818P/PD
FS2424P/PD
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
suggested products for HOSPITAL EXTERIORS:
MILLENIUM™ dark sky luminaires
As more buildings are constructed and equipped with powerful outdoor
lighting systems, light pollution becomes an increasingly significant
problem. Stray light saturates the night sky, emitting visibility-reducing
glare, wasting energy, and producing potentially harmful effects on wildlife.
The Dark Sky movement responds to these issues by raising public and
industry awareness of the problem. The International Dark-Sky Association
(IDA), a leader in the Dark Sky movement, works to preserve the natural
state of night skies by approving outdoor lighting fixtures that prevent
light from being emitted above the horizontal plane. Only fixtures meeting
IDA’s stringent horizontal cutoff criteria earn the IDA-Approved™ Dark-Sky
Friendly Fixture designation.
Kenall’s support of the Dark Sky movement has resulted in our
development of the Millenium Finite™ and Millenium Edge™ families –
superior security fixtures comprised of IDA-Approved™ Dark-Sky Friendly
luminaires. Finite and Edge give lighting professionals IDA-Approved™
Dark Sky fixture solutions featuring Millenium’s category-leading durability,
style, and performance.
Using only the most efficient lamps and ballasts available, Kenall’s Dark
Sky luminaires have specially designed optical systems that deliver
independently certified, full cutoff performance while reducing energy
consumption.
Plus, UL IP64 certification means Kenall’s Dark Sky luminaires are
impervious to dust and moisture. As with all Millenium fixtures,
these luminaires are covered by Kenall’s exclusive Peace of Mind
Lifetime Guarantee™.
APPRO V ED
Dark-Sky Friendly ®
Fixture
Millenium finite™ – wall mount
FN15L
FN15D
FN9L
FN9D
Millenium edge™ – wall & ceiling mount
MR13FF/MR17FF
MR13FFL/MR17FFL
Low Profile
MR13FFD/MR17FFD
Deep Cast Housing
MR13FFR/MR17FFR
Semi-Recessed
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
27
27
suggested products for HOSPITAL EXTERIORS:
herculux™
Kenall’s ever-popular Herculux™ institutional fixture series now comes in
attractive new shapes and sizes, including ADA-compliant models and a
large choice of functional and attractive shielding options – plus a host of
other significant improvements.
Housings, fabricated from heavy-duty, low-copper aluminum, come in
low, medium, or deep versions and can be ordered in a range of finishes.
Optical system choices include the most energy-efficient lamp and ballast
combinations available.
Herculux U.V.-resistant lenses are more durable than ever, with improved
diffusion characteristics that minimize lamp imaging and smooth exteriors
that make cleaning easy.
With the addition of the fully shielded H99DS and H1212DS series to the
Herculux family, lighting professionals now have access to high quality,
IDA Dark Sky-compliant institutional fixtures.
Factor in Kenall’s exclusive Peace of Mind Lifetime Guarantee™ against
breakage and it’s easy to see why more than ever before, Herculux
continues to be the smart choice in institutional high abuse lighting.
herculux™ – wall & ceiling mount
H69FL/FM/FD
H69EL/EM/ED
H612FL/FM/FD H612EL/EM/ED
H99SL/SM/SD H99DSL/DSM/DSD
H1212SL/SM/SD
H1212DSL/DSM/DSD
APPROVED
Dark-Sky Friendly ®
Fixture
H99FL/FM/FD
H1212FL/FM/FD
H99EL/EM/ED
H1212EL/EM/ED
APPROVED
Dark-Sky Friendly ®
Fixture
28
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
suggested products for HOSPITAls:
MILLENIUM METREX™ Exit signs
•Available in single face wall or universal mount, and double
face universal mount
•All polycarbonate construction
•Ease of installation and maintenance
•Long-life LEDs driven at 60% (green) and 25% (red) rated capacity
• Standard battery conditioning, self testing, and self
diagnostics with battery backup
•Laser battery testing standard with battery backup
• Cold weather reliability down to -49°F
•Hot weather reliability up to 113°F
•UL Classified IP64
Millenium METREX™ – wall & ceiling mount
METSW (Single Face)
Wall Mount
METSU (Single Face)
Wall / Ceiling Mount
METSR (Single Face)
Wall Semi-Recessed Mount
METDU (Double Face)
Wall / Ceiling Mount
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
29
29
healthcare specification pages
table of contents
Patient Room Lighting
Ceiling Mount
MPCAIE...........................31
MPCADE.........................32
MPC24.............................33
MPCAE24........................34
MPC22.............................35
MAC22 ...........................36
MAC24............................37
MAC2B14 .......................38
MAC2B22 .......................39
MAC2B24 .......................40
MADC..............................41
MEC22 .......................... 42
MEC8 ............................ 43
MEC12............................ 44
MEC1212S......................45
MEC1212A .................... 46
Patient Room Lighting
Ceiling Mount Downlights
MDL6VL..........................47
MDL6VF..........................48
MDL6HF..........................49
MDL8VF..........................50
MDL8HF..........................51
MDL6VI ..........................52
MDL6HI...........................53
MDL8VI ..........................54
MDL8HI ..........................55
Patient Room Lighting
Wall Mount
MPWF ........................... 56
MPWUD ........................ 57
MWUD .......................... 58
MPWVT ......................... 59
MPWVC . ....................... 60
Patient Room Lighting
Wall Mount Nightlights
MSL .............................. 61
MSLD .............................62
MSLT...............................63
Supplementary Operating
Room Lighting
M2SESI14 ..................... 64
M2SESI22 ..................... 65
M2SESI24 ......................66
M2SEGI14 ..................... 67
M2SEGI22 ..................... 68
M2SEGI24 ..................... 69
M2SEFI14 . .....................70
M2SEFI22 . .................... 71
M2SEFI24 . .................... 72
30
Operating Room Procedural
Exam Lighting
M3SESI22 ..................... 73
M3SESI24 ......................74
M3SEGI22 ..................... 75
M3SEGI24 ..................... 76
M3SEFI22 . .................... 77
M3SEFI24 . .................... 78
Operating Room
Perimeter Lighting
Ceiling Mount Downlights
M2DL6VL........................79
M2DL6VF........................80
M2DL6HF........................81
M2DL8VF........................82
M2DL8HF........................83
M2DL6VI ........................84
M2DL6HI.........................85
M2DL8VI ........................86
M2DL8HI ........................87
MRI Room Lighting
Ceiling Mount Downlights
MRIDL6VL.......................88
MRIDL6VI....................... 89
MRIDL6HI ..................... 90
MRIDL8VI ...................... 91
MRIDL8HI....................... 92
Darkroom Lighting
mdrms ...................... 93
mdrmg ....................... 94
mdrmf . ...................... 95
Graphic Image Lightboxes
CS22............................... 96
CS24 ............................. 97
CS44 .............................. 98
CSMEC .......................... 99
CSMRI22 ..................... 100
CSMRI24 ..................... 101
CSMRI44 ..................... 102
Healthcare Undercabinet
Lighting
MAUCSL....................... 103
MAUCSD .................... 104
MAUCDL ..................... 105
MAUCDD .................... 106
MAUCLED ................... 107
Alpha Numeric Index
CS22............................... 96
CS24 ............................. 97
CS44 .............................. 98
CSMEC .......................... 99
CSMRI22 ..................... 100
CSMRI24 ..................... 101
CSMRI44 ..................... 102
M2DL6HF........................81
M2DL6HI.........................85
M2DL6VF........................80
M2DL6VL........................79
M2DL8HF........................83
M2DL8HI ........................87
M2DL8VF........................82
M2DL8VI ........................86
M2SEFI14 . .....................70
M2SEFI22 . .................... 71
M2SEFI24 . .................... 72
M2SEGI14 ..................... 67
M2SEGI22 ..................... 68
M2SEGI24 ..................... 69
M2SESI14 ..................... 64
M2SESI22 ..................... 65
M2SESI24 ......................66
M3SEFI22 . .................... 77
M3SEFI24 . .................... 78
M3SEGI22 ..................... 75
M3SEGI24 ..................... 76
M3SESI22 ..................... 73
M3SESI24 ......................74
MAC22 ...........................36
MAC24............................37
MAC2B14 .......................38
MAC2B22 .......................39
MAC2B24 .......................40
MADC..............................41
MAUCDD .................... 106
MAUCDL ..................... 105
MAUCLED ................... 107
MAUCSD .................... 104
MAUCSL....................... 103
MDL6HF..........................49
MDL6HI...........................53
MDL6VF..........................48
MDL6VI ..........................52
MDL6VL..........................47
MDL8HF..........................51
MDL8HI ..........................55
MDL8VF..........................50
MDL8VI ..........................54
mdrmf . ...................... 95
mdrmg ....................... 94
mdrms ...................... 93
MEC12............................ 44
MEC1212A .................... 46
MEC1212S......................45
MEC22 .......................... 42
MEC8 ............................ 43
MPC22.............................35
MPC24.............................33
MPCADE.........................32
MPCAE24........................34
MPCAIE...........................31
MPWF ........................... 56
MPWUD ........................ 57
MPWVC . ....................... 60
MPWVT ......................... 59
MRIDL6HI ..................... 90
MRIDL6VI....................... 89
MRIDL6VL.......................88
MRIDL8HI....................... 92
MRIDL8VI ...................... 91
MSL .............................. 61
MSLD .............................62
MSLT...............................63
MWUD .......................... 58
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MPCAIE SERIES
Ceiling Mount–Surface/Grid/Flange
Ambient/Reading/Exam
Lamps: T5HO
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Options): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
ous hinge (20 gauge SS) or aircraft cables and
Phillips head stainless steel fasteners. Closed cell
Neoprene/EPDM/SBR gasket seals lens frame to
housing.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See
Ordering Information for optional equipment.
Lamps by others. Exam area NEC compliant with
isolated wiring compartment for auxiliary branch
circuit feed.
Lens Frame: Supplied with IB Options only
(see Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continu-
Lamp Shielding/Optics: Exam compartment
shielded by perforated metal diffusers with pearlescent overlays and utilizes optically designed
reflectors. Ambient compartment shielded by
pearlescent acrylic diffuser.
Installation:
Surface Mount: Four .312" diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Options UL Listed for Wet Locations and
UL Classified IP65. Low Voltage Controller (LVC)
option Pat. No. D562,767.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 47.00"
(584mm x 1194mm)
Housing
* 5.30"
(135mm)
** 23.25"
(590mm)
** 47.25"
(1200mm)
23.75" x 47.75"
(603mm x 1213mm)
Flange
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty MPCAIE
1/2
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
54
F54T5HO
Lamp Qty (1/2)
Ambient Compartment
1
One Lamp
Exam Compartment
2
Two lamps
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Type
Voltage
Other Options
Accessory
54
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery Pack (32ºF)
(347V dry location only) – Ambient only
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED (Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp
supplied by other) (120/277V only)
LVC Low Voltage Controller (120/277V only)
(See Technical Sheet or consult factory
for switching options)
LRL LED Reading Lights
MRL MR16 Stand-Alone Reading Lights (2)
(120/277V only) (20W watt lamps
included)
RS
Rapid Start Electronic Ballast
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
31
31
MedMaster™
mpcade SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient/Reading/Exam
Lamps: T8
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Options): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB Options only
(see Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) or aircraft cables and Phillips
head stainless steel fasteners. Closed cell silicone
gasket seals lens frame to housing.
Lamp Shielding: Exam compartment shielded
by frosted linear prismatic high impact acrylic.
Ambient compartment shielded by 100% internal
fluted high impact acrylic.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Options UL Listed for Wet Locations and
UL Classified IP65. Low Voltage Controller (LVC)
option Pat. No. D562,767.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" and 1.5" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
22.60" x 48.125"
(574mm x 1222mm)
Housing
**22.875"
(581mm)
*5.58"
(142mm)
**48.375"
(1229mm)
23.35" x 49.28"
(593mm x 1252mm)
Flange
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
Front View
49.00"
49.00"
(1245mm)
(1245mm)
5.90"
(150mm)
2.06"
47.75"
(1213mm)
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty mpcade
2/
Mounting Options
S
Surface
G
Grid (1" and 1.5")
F
Flange
Lamp Qty (2/x)
Ambient Compartment (2)
2
Two Lamps
Exam Compartment (x)
2
Two Lamps
4
Four Lamps
Lamp Type
32
F32T8
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
32
Lamp Type
Voltage
Other Options
Accessory
32
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF)
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp
supplied by other) (120/277V only)
LVC
Low Voltage Controller (120/277V
only) (See Technical Sheet or consult
factory for switching options)
LRL LED Reading Lights
MRL MR16 Reading Lights (2) (120/277V only)
(20W watt lamps included)
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MPC24 SERIES
Ceiling Mount–Surface/Grid/Flange
Ambient/Reading/Exam
Lamps: Biaxial
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lamp Shielding: Exam compartment shielded
by sliding semi-specular aluminum parabolic
louver. ­Clear protective lamp shield securely
fastened above louver (see Ordering Information for alternate Lamp Shield Options). Ambient
compartment lamps shielded by perforated steel
(white TGIC polyester powder coat finish) with
pearlescent acrylic diffuser. Reading compartment
lamp protected by clear lamp shield.
Note: Clear protective lamp shields (exam and
reading) omitted when IB Option is specified.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others. CL Option field adjustable to either side
of bed. One 20W maximum, 12VAC, MR16, 120
or 277 volts. 8° narrow spot recommended. Exam
area NEC compliant with isolated wiring compartment for auxiliary branch circuit feed.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65. Low Voltage
Controller (LVC) option Pat. No. D562,767.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 47.00"
(584mm x 1194mm)
Housing
* 5.80"
(147mm)
** 23.25"
(590mm)
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 47.25"
(1200mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
ORDERING INFORMATION
Series
Mounting Opt
MPC24
Lamp Qty 1/
Lamp Type
Voltage
Lamp Shield Opt
Other Options
Accessories
/
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
40B F40TT (Biax)
50B F50TT (Biax)
55B F55TT (Biax)
Lamp Qty (1/x/x)
Reading Compartment
1
One Lamp
Ambient Compartment (x)
1
One Lamp
2
Two Lamps
Exam Compartment (x)
3
Three Lamps
4
Four Lamps
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Shield Options (Exam Section)
L
Semi-Specular Aluminum Parabolic 3"x3"
Louver with clear acrylic lamp shield
C
Metalized Acrylic Parabolic .5"x.5"
Louver with clear acrylic lamp shield
LW Matte White 3"x3" Louver with clear
acrylic lamp shield
I
.125" #12 Prismatic Acrylic
SL
Specified Louver
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only)
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
LVC
LCL
CL
Low Voltage Controller (120/277V
only) (See Technical Sheet or consult
factory for switching options)
LED Chart Light
Chart Light – 20W MR16
(Lamp by other) (120/277V only)
Accessories
IF
Install Frame (Flange only)
C-2063Lamp, 20W MR16 12VAC 8° Spot
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
33
33
MedMaster™
MPCAE24 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient/Exam
Lamps: Biaxial
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
or 277 volts. 8° narrow spot recommended. Exam
area NEC compliant with isolated wiring compartment for auxiliary branch circuit feed.
Lamp Shielding: Exam compartment shielded
by sliding semi-specular aluminum parabolic
louver. ­Clear protective lamp shield securely
fastened above louver (see Ordering Information for alternate Lamp Shield Options). Ambient
compartment lamps shielded by perforated steel
(white TGIC polyester powder coat finish) with
pearlescent acrylic diffuser.
Note: Exam compartment clear protective lamp
shield omitted when IB Option is specified.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others. CL Option field adjustable to either side
of bed. One 20W maximum, 12VAC, MR16, 120
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65. Low Voltage
Controller (LVC) option Pat. No. D562,767.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 47.00"
(584mm x 1194mm)
Housing
* 5.80"
(147mm)
** 23.25"
(590mm)
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 47.25"
(1200mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
ORDERING INFORMATION
Series
Mounting Opt
MPCAE24
34
Lamp Qty Lamp Type
Voltage
Lamp Shield Opt
Other Options
Accessories
/
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
40B F40TT (Biax)
50B F50TT (Biax)
55B F55TT (Biax)
Lamp Qty (x/x)
Ambient Compartment (x)
1
One Lamp
2
Two Lamps
Exam Compartment (x)
3
Three Lamps
4
Four Lamps
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Shield Options (Exam Section)
L
Semi-Specular Aluminum Parabolic 3"x3"
Louver with clear acrylic lamp shield
C
Metalized Acrylic Parabolic .5"x.5"
Louver with clear acrylic lamp shield
LW Matte White 3"x3" Louver with clear
acrylic lamp shield
I
.125" #12 Prismatic Acrylic
SLSpecified Louver
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only) –
Ambient only
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
LVC
LCL
CL
Accessories
IF
Install Frame (Flange only)
C-2063Lamp, 20W MR16 12VAC 8° Spot
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Low Voltage Controller (120/277V only)
(See Technical Sheet or consult
factory for switching options)
LED Chart Light
Chart Light – 20W MR16
(Lamp by other) (120/277V only)
MedMaster™
MPC22 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient/Reading
Lamps: Biaxial
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Lamp Shielding: Ambient compartment lamps
shielded by perforated steel (white TGIC polyester powder coat finish) with pearlescent acrylic
diffuser. Reading compartment lamp protected by
clear lamp shield.
Note: Clear lamp shield (reading) omitted when IB
Option is specified.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
ware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65. Low Voltage
Controller (LVC) option Pat. No. D562,767.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hard-
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 23.00"
(584mm x 584mm)
Housing
** 23.25"
(590mm)
* 5.80"
(147mm)
23.75" x 23.75"
(603mm x 603mm)
Flange
** 23.25"
(590mm)
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty MPC22
1/
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
36B F36TT (Biax)
Lamp Qty (1/X)
Reading Compartment
1
One Lamp
Ambient Compartment
1
One Lamp
2
Two Lamps
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Type
Voltage
Other Options
Accessory
36B
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only) –
Ambient only
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
LVC
Low Voltage Controller (120/277V only)
(See Technical Sheet or consult factory
for switching options)
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
35
35
MedMaster™
MAC22 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps: Biaxial
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Lamp Shielding: Perforated steel (white TGIC
polyester powder coat finish) with pearlescent
acrylic diffuser.
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 23.00"
(584mm x 584mm)
Housing
** 23.25"
(590mm)
* 5.80"
(147mm)
23.75" x 23.75"
(603mm x 603mm)
Flange
** 23.25"
(590mm)
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty Lamp Type
Voltage
Other Options
Accessory
MAC22
36
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
40B F40TT (Biax)
50B F50TT (Biax)
55B F55TT (Biax)
Lamp Qty
1
One Lamp
2
Two Lamps
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only)
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MAC24 SERIES
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps: T5HO
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Lamp Shielding: Perforated steel (white TGIC
polyester powder coat finish) with pearlescent
acrylic diffuser.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 47.00"
(584mm x 1194mm)
Housing
** 23.25"
(590mm)
* 5.80"
(147mm)
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 47.25"
(1200mm)
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty MAC24
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Qty
1
One Lamp
2
Two Lamps
Lamp Type
Voltage
Other Options
Accessory
54
Lamp Type
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
RS
Rapid Start Electronic Ballast
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
37
37
MedMaster™
MAC2B14 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps:T8, T5, T5HO
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 1' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Mitered and welded
corners. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: Heavy duty extruded marine grade
aluminum with clear satin anodized finish. Lens
frame secured to housing with aircraft cables
and captive mounted Phillips head stainless steel
fasteners.
Lamp Shielding: Two perforated aluminum
baskets (white TGIC polyester powder coat finish)
with pearlescent acrylic diffuser.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" and 1.5" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
DIMENSIONAL DATA
Cross SectionGrid Side View (T8 Lamps)
T8 Lamps
10.60" x 48.00"
(269mm x 1219mm)
Housing
T5 & T5HO Lamps
10.60" x 46.60"
(269mm x 1184mm)
Housing
Recommended Ceiling Cutout
48.00"
(1219mm)
1.40"
(36mm)
6.10"
(155mm)
2.00"
(51mm)
T5 & T5HO
Lamps
** 46.875"
(1191mm)
T8
Lamps
** 48.375"
(1229mm)
** 10.875"
(276mm)
47.75"
(1213mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
11.75" x 47.75"
(298mm x 1213mm)
Flange
ORDERING INFORMATION
Series
Mounting Opt
MAC2B14
Lamp Qty Lamp Type
Ballast Type
2
Ballast Qty
Voltage
Lens Frame
Other Options
Accessory
1
Mounting Options
S
Surface
G
Grid (1"and 1.5")
F
Flange
Lamp Type
28** F28T5
32
F32T8
54** F54T5HO
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Qty
2
Two Lamps
Ballast Type
IS
Instant Start Electronic
<10% THD (T8)
RS
Rapid Start Electronic
<10% THD (T8,T5,T5HO)
SB
Specified Ballast
Lens Frame
AF
Anodized Aluminum (STD)
PAF Painted Extruded Aluminum
Ballast Qty
1
One
Other Options
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only)
RF
Radio Frequency Filter (1 per ballast)
(120/277V only)
FS
Fuse & Holder (1 per ballast)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
HD
Continuous Piano Hinge
Accessory
IF
Install Frame (Flange only)
** Available with RB ballast only.
38
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MAC2B22 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps: T8, T5HO, Biaxial
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Mitered and welded
corners. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: Heavy duty extruded marine grade
aluminum with clear satin anodized finish. Lens
frame secured to housing with Phillips head stainless steel fasteners held in place for servicing
with two aircraft cables.
Lamp Shielding: Two perforated aluminum
baskets (white TGIC polyester powder coat finish)
with pearlescent acrylic diffuser.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" and 1.5" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
DIMENSIONAL DATA
Cross SectionGrid Side View (T8, 40B, 50B Lamps)
Recommended Ceiling Cutout
T5HO,
F55TT
Lamps
T8,
F40TT,
F50TT
Lamps
T8, F40TT, F50TT Lamps
22.60" x 24.00"
(574mm x 610mm)
Housing
T5HO, F55TT Lamps
22.60" x 22.60"
(574mm x 574mm)
Housing
24.00"
(610mm)
1.40"
(36mm)
6.10"
(155mm)
** 24.375"
(619mm)
2.00"
(51mm)
23.75"
(603mm)
23.75" x 23.75"
(603mm x 603mm)
Flange
** 22.875"
(581mm)
** 22.875"
(581mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty Lamp Type
Ballast Type
Ballast Qty
Voltage
Lens Frame
Other Options
Accessory
MAC2B22
Mounting Options
S
Surface
G
Grid (1" and 1.5")
F
Flange
Lamp Qty
2
Two Lamps
4*
Four Lamps
Lamp Type
17
F17T8
24** F24T5HO
40B F40TT (Biax)
50B F50TT (Biax)
55B F55TT (Biax)
Ballast Type
IS
Instant Start Electronic
<10% THD (T8)
RS
Rapid Start Electronic
<10% THD (CFL,T8,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lens Frame
AF
Anodized Aluminum (STD)
PAF Painted Extruded Aluminum
Ballast Qty
1
One
2
Two
Other Options
EL
One-Lamp Emergency Battery Pack (32ºF)
(347V dry location only)
RF
Radio Frequency Filter (1 per ballast)
(120/277V only)
FS
Fuse & Holder (1 per ballast)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
HD
Continuous Piano Hinge
Accessory
IF
Install Frame (Flange only)
* Not available for Biax lamps.
** Available with RB ballast only.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
39
39
MedMaster™
MAC2B24 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Mitered and welded
corners. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: Heavy duty extruded marine grade
aluminum with clear satin anodized finish. Lens
frame secured to housing with Phillips head stainless steel fasteners held in place for servicing
with two aircraft cables.
Lamp Shielding: Two perforated aluminum
baskets (white TGIC polyester powder coat finish)
with pearlescent acrylic diffuser.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" and 1.5" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
DIMENSIONAL DATA
Cross SectionGrid Side View (T8 Lamps)
Recommended Ceiling Cutout
T8 Lamps
22.60" x 48.00"
(574mm x 1219mm)
Housing
T5 & T5HO Lamps
22.60" x 46.60"
(574mm x 1184mm)
Housing
T5 & T5HO
Lamps
** 46.875"
(1191mm)
T8
Lamps
** 48.375"
(1229mm)
48.00"
(1219mm)
1.40"
(36mm)
6.10"
(155mm)
2.00"
(51mm)
47.75"
(1213mm)
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 22.875"
(581mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty Lamp Type
Ballast Type
Ballast Qty
Voltage
Lens Frame
Other Options
Accessory
MAC2B24
Mounting Options
S
Surface
G
Grid (1" and 1.5")
F
Flange
Lamp Type
28** F28T5
32
F32T8
54** F54T5HO
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Qty
2
Two Lamps
4
Four Lamps
Ballast Type
IS
Instant Start Electronic
<10% THD (T8)
RS
Rapid Start Electronic
<10% THD (T8,T5,T5HO)
SB
Specified Ballast
Lens Frame
AF
Anodized Aluminum (STD)
PAF Painted Extruded Aluminum
Ballast Qty
1
One
2
Two
Other Options
EL
One-Lamp Emergency Battery Pack (32ºF)
(347V dry location only)
RF
Radio Frequency Filter (1 per ballast)
(120/277V only)
FS
Fuse & Holder (1 per ballast)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
HD
Continuous Piano Hinge
Accessory
IF
Install Frame (Flange only)
** Available with RB ballast only.
40
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MADC22 / MADC24 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface/Grid/Flange
Ambient
Lamps: T5HO, Biaxial
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 2' x 2', 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Lamp Shielding: Center pearlescent acrylic
diffuser with side perforated steel (white TGIC
polyester powder coat finish) with pearlescent
acrylic diffusers.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout 2'x2'
Recommended Ceiling Cutout 2'x4'
23.00" x 23.00"
(584mm x 584mm)
2’X2’ Housing
23.00" x 47.00"
(584mm x 1194mm)
Housing
23.00" x 47.00"
(584mm x 1194mm)
2’X4’ Housing
* 5.80"
(147mm)
** 23.25"
(590mm)
* 5.80"
(147mm)
23.75" x 23.75"
(603mm x 603mm)
2’X2’ Flange
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 23.25"
(590mm)
** 23.25"
(590mm)
** 47.25"
(1200mm)
23.75" x 47.75"
**Barrier
Add .25"
each cut-out
dimension when
Install
** Add
.25" to each cut-out dimension when Install
* Add .25" to fixture height when Ingress
(IB)toOption
is specified
(603mm x 1213mm)
Frame (IF) Accessory is specified
Frame (IF) Accessory is specified
2’X4’ Flange
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
ORDERING INFORMATION
Series
Size
Mounting Opt
Lamp Qty Lamp Type
Voltage
Other Options
Accessory
MADC
Size
22
24
2' x 2'
2' x 4'
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Qty
1
One Lamp
2
Two Lamps
Lamp Type
40B F40TT (Biax) (2'x2' only)
50B F50TT (Biax) (2'x2' only)
55B F55TT (Biax) (2'x2' only)
54
F54T5HO (2'x4' only)
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
EL
One-Lamp Emergency Battery
Pack (32ºF) (347V dry location only)
GEN Interim Lighting for Generator
Backup Systems (2'x2',120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Night Light – White Light LED
(Supplied) (120/277V only)
TN
Night Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
RS
Rapid Start Electronic Ballast (2'x4' only)
Accessory
IF
Install Frame (Flange only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
41
41
MedMaster™
MEC22 SERIES
Ceiling Mount–Surface/Grid/Flange
Exam
Lamps: Biaxial
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Lamp Shielding: Semi-specular aluminum
parabolic louver. ­Clear protective lamp shield
securely fastened above louver (see Ordering
Information for alternate Lamp Shield Options).
Note: Clear lamp shield omitted when IB Option
is specified.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others. CL Option field adjustable to either side
of bed. One 20W maximum, 12VAC, MR16, 120
or 277 volts. 8° narrow spot recommended.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
23.00" x 23.00"
(584mm x 584mm)
Housing
** 23.25"
(590mm)
* 5.80"
(147mm)
23.75" x 23.75"
(603mm x 603mm)
Flange
** 23.25"
(590mm)
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Mounting Opt
Lamp Qty Lamp Type
Voltage
Lamp Shield Opt
Other Options
Accessories
MEC22
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Lamp Qty
3
Three Lamps
4
Four Lamps
Lamp Shield Options (Exam Section)
L
Semi-Specular Aluminum Parabolic 3"x3"
Louver with clear acrylic lamp shield
C
Metalized Acrylic Parabolic .5"x.5"
Louver with clear acrylic lamp shield
LW Matte White 3"x3" Louver with clear
acrylic lamp shield
I
.125" #12 Prismatic Acrylic
SL
Specified Louver
Lamp Type
40B F40TT (Biax)
50B F50TT (Biax)
55B F55TT (Biax)
42
Other Options
IB-HD Ingress Barrier (Adds 1/4" height)
with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height)
with Aircraft Cables
GEN Interim Lighting for Generator
Backup Systems (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
CL* Chart Light – 20W MR16
(Lamp by other) (120/277V only)
LRL LED Reading Lights
Accessories
IF
Install Frame (Flange only)
C-2063Lamp, 20W MR16 12VAC 8° Spot
* Ordered with Lamp Shield "L" Option only.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MEC8 SERIES
Ceiling Mount–Surface/Grid/Flange
Exam–Asymmetric
Lamps: T5, T5HO
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 8" × 48"
Nominal 8" × 60"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with clear satin anodized finish.
Lens frame secured to housing with continuous
hinge (20 gauge SS) and Phillips head stainless
steel fasteners. Closed cell silicone gasket seals
lens frame to housing.
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lamp Shielding: Perforated steel (white TGIC
polyester powder coat finish) with pearlescent
diffuser.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
4' Fixture
8.00" x 47.00"
(203mm x 1194mm)
5' Fixture
8.00" x 59.00"
(203mm x 1498mm)
Housing
** 8.25"
(209mm)
4' Fixture
** 47.25"
(1200mm)
* 3.00"
(76mm)
4' Fixture
8.75" x 47.75"
(222mm x 1213mm)
5' Fixture
** 59.25"
(1505mm)
5' Fixture
8.75" x 59.75"
(222mm x 1517mm)
Flange
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Length
Mounting Opt
Lamp Qty Lamp Type
Voltage
Other Options
Accessory
MEC8
Nominal Length
48
4'
60
5'
Lamp Qty
1
One Lamp
2
Two Lamps
Mounting Options
S
Surface
G
Grid (1")
F
Flange
Lamp Type
Four Foot Lengths
28
F28T5
54
F54T5HO
Five Foot Lengths
35
F35T5
80
F80T5HO
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Accessory
IF
Install Frame (Flange only)
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
RS
Rapid Start Electronic Ballast
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
43
43
MedMaster™
MEC12 SERIES
Ceiling Mount–Surface/Grid/Flange
Exam–Asymmetric
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 1' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Flange and Grid – 20 gauge CRS;
Surface – 18 gauge CRS. One-piece seam welded
construction. Housing Flange: Flange and Grid
– 18 gauge CRS, standard 4-piece construction,
spot-welded to housing. Ingress Barrier (IB Option): Mitered and welded corners, spot-welded
to housing. Housing Finish: White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Inside Flanges: 18 gauge CRS; fastened to
housing. Black matte TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours.
Lens Frame: Supplied with IB option only (see
Other Options). Heavy duty extruded marine
grade aluminum with anodized finish. Lens frame
secured to housing with continuous hinge (20
gauge SS) and Phillips head stainless steel fasteners. Closed cell silicone gasket seals lens frame
to housing.
Lamp Shielding: Perforated steel (white TGIC
polyester powder coat finish) with pearlescent
diffuser.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See Ordering Information for optional equipment. Lamps
by others.
Installation: Surface Mount: Four .312"
diameter holes.
Grid Mount: Designed for 1" grid. Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Damp Locations. IB Option UL Classified IP65.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
T5 Lamps
11.00" x 47.00"
(279mm x 1194mm)
T8 Lamps
11.00" x 48.75"
(279mm x 1238mm)
** 11.25"
(286mm)
* 4.00"
(101mm)
T5 Lamps
** 47.25"
(1200mm)
T5 Lamps
11.75" x 47.75"
(298mm x 1213mm)
T8 Lamps
** 49.00"
(1244mm)
T8 Lamps
11.75" x 49.50"
(298mm x 1257mm)
* Add .25" to fixture height when Ingress Barrier (IB) Option is specified
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified
ORDERING INFORMATION
Series
Length
MEC12
Nominal Length
48
4'
Mounting Options
S
Surface
G
Grid (1")
F
Flange
44
Mounting Opt
Lamp Qty Lamp Type
Voltage
Other Options
Accessory
48
Lamp Qty
1
One Lamp
2
Two Lamps
Lamp Type
28
F28T5
32
F32T8
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Accessory
IF
Install Frame (Flange only)
Other Options
IB-HD Ingress Barrier (Adds 1/4" height) with Continuous Piano Hinge
IB-AC Ingress Barrier (Adds 1/4" height) with Aircraft Cables
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
RS
Rapid Start Electronic Ballast
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
MEC1212s SERIES
Ceiling Mount/Recessed Flange
Quartz Exam–Symmetric
Lamps: Tungsten Halogen
Antimicrobial Finish Standard
PROJECT INFORMATION
Job Name
Dimensions
Nominal 12" × 12"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. TIG welded construction. White TGIC polyester powder coat – 5-stage
pre-treatment. Salt spray test: 1,000 hours;
Reflectance: 92%. Standard antimicrobial finish.
Door: 18-Gauge CRS. Door secured to housing
with 4 Phillips head stainless steel fasteners.
Optional door with stainless steel full length piano
hinge and 2 Phillips head stainless steel fasteners.
Housing Flange: 18-Gauge CRS. Mitered and
welded corners then spot-welded to housing.
Lens: Fresnel focusing lens.
Reflector: Ellipsoidal aluminum bright dipped
anodized.
Listings: UL and CUL Listed for Damp Locations. NSF2 –­ Splash Non-Food Zone.
Electrical: Mini can 250 watt quartz porcelain
socket. 120V only.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
12.00"
(305mm)
12.25"
11.25"
(311mm)
(286mm)
13.40"
12.25"
(340mm)
(311mm)
ORDERING INFORMATION
Series
MEC1212s
Lamp Qty
1
One Lamp
Lamp Qty 1
Lamp Type
Voltage
250Q
120
Lamp Type
250Q 250W Tungsten Halogen
Door Option
Other Options
2H
Door Option
2H
18 Ga CRS
Voltage
120 120 Volts
Other Options
PF
Plaster Frame
WMT Wall Mount Timer (1-15 minutes)
HD
Hinged Door (w/o NSF listing)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
45
45
MedMaster™
MEC1212A SERIES
PROJECT INFORMATION
Ceiling Mount/Recessed Flange
Quartz Exam–Asymmetric
Lamps: Tungsten Halogen
Antimicrobial Finish Standard
Job Name
Dimensions
Nominal 12" × 12"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. TIG welded construction. TGIC polyester powder coat – 5-stage pretreatment. Salt spray test: 1,000 hours. Standard
antimicrobial finish.
Door: 18-Gauge CRS. Door secured to housing
with 4 Phillips head stainless steel fasteners.
Optional door with stainless steel full length piano
hinge and 2 Phillips head stainless steel fasteners.
Housing Flange: 18-Gauge CRS. Mitered and
welded corners then spot-welded to housing.
Lens: Fresnel focusing lens.
Reflector: Ellipsoidal aluminum bright dipped
anodized.
Listings: UL and CUL Listed for Damp Locations. NSF2 –­ Splash Non-Food Zone.
Electrical: Mini can 250 watt quartz porcelain
socket. 120V only.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
12.00"
(305mm)
12.25"
11.25"
(311mm)
(286mm)
13.40"
12.25"
(340mm)
(311mm)
ORDERING INFORMATION
Series
Lamp Qty MEC1212A
Lamp Qty
1
One Lamp
1
Lamp Type
Voltage
250Q
120
Lamp Type
250Q 250W Tungsten Halogen
Door Options
Door Option
2H
18 Ga CRS
Voltage
120 120 Volts
46
Other Options
2H
Other Options
PF
Plaster Frame
WMT Wall Mount Timer (1-15 minutes)
HD
Hinged Door (w/o NSF listing)­­
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
MDL6VL SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: LED
Job Name
Dimensions
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
Electrical: Electronic LED driver. See Ordering
Information for optional equipment.
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.00”
(457mm)
3.47”
(88mm)
6.375”
(162mm)
Aperture
16.00”
(406mm)
1.375”
max ceiling
8.63”
(219mm)
21.48”
(546mm)
ORDERING INFORMATION
Series
Lamp Type
Color Temp
Voltage
Trim
mdl6vl
Lamp Type
L22 22 Watt LED
L38 38 Watt LED
Color Temperature
35K 3500K
41K 4100K
Voltage
120 120 Volts
277 277 Volts
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
Polycarbonate
2
.125" #12 Prismatic
Specified Lens
SL Specified Lens
Other Options
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
DM Dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
47
47
MedMaster™ Downlight
MDL6VF SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: CFL
Job Name
Dimensions
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See
Ordering Information for optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
photometrics: Efficiency of MDL6VF-1-32PRS-DV-2FW-PAH-CS-G = 52%; S/MH = 1.1,1.1.
For additional photometric information, go to
www.kenall.com.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
16.13”
(410mm)
10.58”
(269mm)
16.13”
(410mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
19.60”
(498mm)
8.63”
(219mm)
ORDERING INFORMATION
Series
Lamp Qty
mdl6vF
Lamp Type
Lamp Quantity
1
One
Lamp Type
13Q 13 Watt Quad
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
SB Specified Ballast
48
Ballast Type
Voltage
Trim
1
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
DV
120/277 Volts
347
347 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
MDL6HF SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: CFL
Job Name
Dimensions
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See
Ordering Information for optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
photometrics: Efficiency of MDL6HF-1-32PDV-2FW-PAH-CS-G = 58.9%; S/MH = 1.3,1.3.
For additional photometric information, go to
www.kenall.com.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.12”
(460mm)
6.08”
(155mm)
17.00”
(432mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
8.63”
(219mm)
21.60”
(549mm)
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type
Ballast Type
Voltage
mdl6HF
Trim
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
2
Two
Voltage
DV
120/277 Volts
347
347 Volts
Lamp Type
13Q 13 Watt Quad
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT (1 lamp only)
26P 26 Watt PLT (1 lamp only)
32P 32 Watt PLT (1 lamp only)
42P 42 Watt PLT (1 lamp only)
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
SB Specified Ballast
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
49
49
MedMaster™ Downlight
MDL8VF SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: CFL
Job Name
Dimensions
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See
Ordering Information for optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
photometrics: Efficiency of MDL8VF-1-32PRS-DV-2FW-PAH-CS-G = 59%; S/MH = 1.2,1.2.
For additional photometric information, go to
www.kenall.com.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
16.13”
(410mm)
16.13”
(410mm)
12.58”
(318mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
19.60”
(498mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
mdl8vF
Lamp Type
Lamp Quantity
1
One
Lamp Type
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
SB Specified Ballast
50
Ballast Type
Voltage
Trim
1
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
DV
120/277 Volts
347
347 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
MDL8HF SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: CFL
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). See
Ordering Information for optional equipment.
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
photometrics: Efficiency of MDL8HF-1-42PDV-2FW-PAH-CS-G = 69.4%; S/MH = 1.4,1.2.
For additional photometric information, go to
www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
21.87”
(556mm)
8.08”
(205mm)
17.00”
(432mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
25.35”
(549mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type
Ballast Type
Voltage
mdl8HF
Trim
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
2
Two
Voltage
DV
120/277 Volts
347
347 Volts
Lamp Type
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
SB Specified Ballast
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
51
51
MedMaster™ Downlight
MDL6VI SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MDL6VI-1100A19-120-2FW-PAH-CS-8 = 47%; S/MH =
0.7,0.7. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
16.13”
(410mm)
10.58”
(269mm)
6.375”
(162mm)
Aperture
16.13”
(410mm)
17.91”
(455mm)
1.375”
max ceiling
19.60”
(498mm)
8.63”
(219mm)
ORDERING INFORMATION
Series
Lamp Qty
mdl6vI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75P30S 75 Watt Incandescent (Par30S)
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
52
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
MDL6HI SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MDL6HI-1100A19-120-2FW-PAH-CS-8 = 53.7%; S/MH =
1.3,1.2. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.12”
(460mm)
5.08”
(129mm)
6.375”
(162mm)
Aperture
17.00”
(432mm)
18.78”
(477mm)
1.375”
max ceiling
8.63”
(219mm)
21.60”
(549mm)
ORDERING INFORMATION
Series
mdl6HI
Lamp Qty
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
53
53
MedMaster™ Downlight
MDL8VI SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MDL8VI-1100A19-120-2FW-PAH-CS-8 = 60%; S/MH =
0.8,0.8. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
16.13”
(410mm)
8.375”
(213mm)
Aperture
16.13”
(410mm)
17.91”
(455mm)
12.58”
(318mm)
1.375”
max ceiling
19.60”
(498mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
mdl8vI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75P30S 75 Watt Incandescent (Par30S)
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
250P38 250 Watt Incandescent (Par38)
Hsg Options
Reflector Finish Lens Options
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
54
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
MDL8HI SERIES for
patient rooms & general areas
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MDL8HI-1200A21-120-2FW-PAH-CS-8 = 64.3%; S/MH =
0.7,1.1. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
21.87”
(556mm)
17.00”
(432mm)
18.78”
(477mm)
7.08”
(180mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
25.35”
(549mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
mdl8HI
Lamp Qty
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
55
55
MedMaster™
MPWF SERIES (FLip Open)
PROJECT INFORMATION
Wall Mount–Surface
Ambient/Reading/Procedural
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimension
Nominal 5" × 24", 5" × 36", 5" × 48"
Fixture Type
Catalog Number Shown in open position
Approved by
SPECIFICATIONS
Housing: Extruded aluminum body with diecast end caps. Housing attached to mounted
baseplate for wiring with integral swing hook.
After wiring, housing swings closed; secured with
countersunk fasteners. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Baseplate: 16 gauge CRS baseplate provided
with four-point (24" housing) or six-point (36" and
48" housing) mounting holes and one wireway
hole.
Installation: Standard four-point (24" housing)
or six-point (36" and 48" housing) mounting.
Lens: U.V. stabilized, high impact resistant,
extruded linear DR/acrylic (50/50 blend). Smooth
exterior, fluted interior. Nominal thickness .125".
Lens securely positioned in body channels.
Electrical: Fluorescent electronic
120/277/347V ballasts high power factor (<10%
THD). One ballast for upper compartment and one
ballast for lower compartment standard. Circuits
supplied with quick connects/disconnects. See
Ordering Information for optional equipment.
Lamps by others.
Listings: UL and CUL Listed for Damp
Locations. Certified by independent lab to meet
OSHPD seismic loading standard. Pre-approved
by OSHPD for installation in California healthcare
facilities. US Patent No. D527,131. Low Voltage
Controller (LVC) option Pat. No. D562,767.
DIMENSIONAL DATA
Cross SectionInstallation Details
(2) .875" Dia. KOs
5.59"
(142mm)
.875" Dia. Hole
3.25"
(83mm)
5.00"
(127mm)
2.00" Dia. KO
19.38"
(492mm)
5.00"
(127mm)
44.00"
(1118mm)
12.61"
(320mm)
2.63"
(67mm)
T5, T5HO
47.82"
(1215mm)
(6) .312" Dia.
Mtg. Holes
T8
49.78"
(1264mm)
ORDERING INFORMATION
Series
Length
Finish
Lamp Config Lamp Type
Ballast Type
Voltage
Options
MPWF
Nominal Length
24
2'
36
3'
48
4'
Finish
MW Matte White Antimicrobial (STD)
CC
Custom Color Antimicrobial
(Consult factory)
Lamp Configuration
22
2 Up 2 Down
21
2 Up 1 Down
12
1 Up 2 Down
11
1 Up 1 Down
56
Lamp Type
Two Foot Lengths
14*■ F14T5
17● F17T8
24■ F24T5HO
Three Foot Lengths
21*▲ F21T5
25† F25T8
39
F39T5HO
Four Foot Lengths
28‡ F28T5
32
F32T8
54‡** F54T5HO
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Options
HGO Hospital Grade Grounded Outlet –
20A, 125V
EL
One-Lamp (Downlight) Emergency
Battery Pack (32ºF) (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN** Chart Light – White Light LED
(Supplied) (120/277V only)
TN** Chart Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only)
PCC Pull Chain Center (4 position)(120V only)
PCL Pull Chain Left (4 position)(120V only)
PCR
ES
LVC
* 120/277 volts only.
■
Not available with EL or LVC options.
●
EL option not available. LN and TN options
not available with HGO/LVC or RF/LVC option
combinations.
▲
EL option not available with TN, RF, ES, or
LVC options.
† EL option not available with LVC option.
‡ EL/LVC option combination not available with
ES, TN, or RF options.
** Available in 1 Lamp Down configuration only.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Pull Chain Right (4 position)(120V only)
Emergency Shut-Off Switch (120V rated)
Low Voltage Controller (120/277V
only) (See Technical Sheet or consult
factory for switching options)
MedMaster™
MPWUD SERIES (Non-Flip Open)
PROJECT INFORMATION
Wall Mount–Surface
Ambient/Reading
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimension
Nominal 6" × 25.5", 6" × 37.5", 6" × 49.5"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: Extruded aluminum body with diecast end caps. Housing attached to mounted
baseplate. Housing secured with countersunk
fasteners. White TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours; Reflectance: 92%. Standard antimicrobial
finish.
Baseplate: 16-gauge CRS baseplate provided
with four-point (24” housing) or six-point (48”
housing) mounting holes and one wireway hole.
Listings: UL and CUL Listed for Damp
Locations. Certified by independent lab to meet
OSHPD seismic loading standard. Pre-approved
by OSHPD for installation in California healthcare
facilities. Low Voltage Controller (LVC) option Pat.
No. D562,767.
Lens: U.V. stabilized, high impact resistant,
extruded linear DR/acrylic (50/50 blend). Smooth
exterior, fluted interior. Nominal thickness .125".
Lens securely positioned in body channels.
Electrical: Fluorescent electronic
120/277/347V ballasts high power factor (<10%
THD). One ballast per lamp compartment. See
Ordering Information for optional equipment.
Lamps by others.
Installation: Standard four-point (24" housing)
or six-point (48" housing) mounting.
DIMENSIONAL DATA
Cross SectionInstallation Details
(2) .875" Dia. KOs
.875" Dia. Hole
3.25"
(83mm)
6.00"
(152mm)
6.00"
(152mm)
2.00" Dia. KO
19.38"
(492mm)
7.75"
(197mm)
44.00"
(1118mm)
2.63"
(67mm)
T5, T5HO
47.50"
(1206mm)
(6) .312" Dia.
Mtg. Holes
T8
49.50"
(1257mm)
ORDERING INFORMATION
Series
Length
Finish
Lens Type
Lamp Config Lamp Type
Ballast Type
Voltage
Options
MPWUD
Nominal Length
24
2'
36
3'
48
4'
Finish
MW
MB
SL
CC
Matte White Antimicrobial (STD)
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
(Consult Factory)
Lens Type
CP
Clear Prismatic (STD)
FA
Frost Acrylic
Lamp Configuration
22
2 Up 2 Down
21
2 Up 1 Down
12
1 Up 2 Down
11
1 Up 1 Down
01
0 Up 1 Down (solid top)
02
10
20
0 Up 2 Down (solid top)
1 Up 0 Down (solid bottom)
2 Up 0 Down (solid bottom)
Lamp Type
Two Foot Lengths
14*■ F14T5
17 ● F17T8
24*■ F24T5HO
Three Foot Lengths
21*▲ F21T5
25† F25T8
Four Foot Lengths
28‡ F28T5
32
F32T8
54‡ F54T5HO
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Options
HGO**Hospital Grade Grounded Outlet –
20A, 125V
GFI** Ground Fault Outlet
EL
One-Lamp (Downlight) Emergency
Battery Pack (32ºF) (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
LN
Chart Light – White Light LED (Supplied)
(120/277V only) (1 Lamp Down only)
TN
Chart Light – 5/7/9 Watt PL (Lamp supplied by other) (120/277V only) (1 Lamp
Down only)
PCL Pull Chain Left (4 position)(120V only)
PCR Pull Chain Right (4 position)(120V only)
ES
LVC
SW
TR
Emergency Shut-Off Switch (120V rated)
Low Voltage Controller (120/277V only)
(See Technical Sheet or consult factory
for switching options)
Rocker Switch (1 per circuit)
Tamper Resistant Posi-Grip Fastener
* 120/277 volts only.
■
Not available with EL or LVC options.
●
EL option not available. LN and TN options
not available with HGO/LVC or RF/LVC option
combinations.
▲
EL option not available with TN, RF, ES, or
LVC options.
† EL option not available with LVC option.
‡ EL/LVC option combination not available with
ES, TN, or RF options.
** Not available in combination with EL, PC, or
SW options.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
57
57
MedMaster™
MWUD SERIES
PROJECT INFORMATION
Wall Mount–Surface
Up/Down–Non-Partitioned
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimension
Nominal 6" × 25.5", 6" × 37.5", 6" × 49.5"
Fixture Type
Catalog Number Shown with optional
Clear Prismatic lens
Approved by
SPECIFICATIONS
Housing: Extruded aluminum body with diecast end caps. Housing attached to mounted
baseplate. Housing secured with countersunk
fasteners. White TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours; Reflectance: 92%. Standard antimicrobial
finish.
Baseplate: 16-gauge CRS baseplate provided
with four-point (24” housing) or six-point (48”
housing) mounting holes and one wireway hole.
Listings: UL and CUL Listed for Damp
Locations. Certified by independent lab to meet
OSHPD seismic loading standard. Pre-approved
by OSHPD for installation in California healthcare
facilities. Low Voltage Controller (LVC) option Pat.
No. D562,767.
Lens: U.V. stabilized, high impact resistant,
100% DR frost acrylic. Smooth exterior. Nominal
thickness .080". Lens securely positioned in body
channels.
Electrical: Fluorescent electronic
120/277/347V ballasts high power factor (<10%
THD). See Ordering Information for optional
equipment. Lamps by others.
Installation: Standard four-point (24" housing)
or six-point (48" housing) mounting.
DIMENSIONAL DATA
Cross SectionInstallation Details
(2) .875" Dia. KOs
.875" Dia. Hole
3.25"
(83mm)
6.00"
(152mm)
6.00"
(152mm)
2.00" Dia. KO
19.38"
(492mm)
7.75"
(197mm)
44.00"
(1118mm)
2.63"
(67mm)
T5, T5HO
47.50"
(1206mm)
(6) .312" Dia.
Mtg. Holes
T8
49.50"
(1257mm)
ORDERING INFORMATION
Series
Length
Finish
Lens Type
Lamp Config Lamp Type
Ballast Type
Voltage
Options
MWUD
Nominal Length
24
2'
36
3'
48
4'
Finish
MW
MB
SL
CC
Matte White Antimicrobial (STD)
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial (Consult Factory)
Lens Type
FA
Frost Acrylic (STD)
CP
Clear Prismatic
Lamp Configuration
1
1 Lamp
2
2 Lamps
3
3 Lamps
58
4
01
02
10
20
4 Lamps
0 Up 1 Down (solid top)
0 Up 2 Down (solid top)
1 Up 0 Down (solid bottom)
2 Up 0 Down (solid bottom)
Lamp Type
Two Foot Lengths
14*■ F14T5
17● F17T8
24*■ F24T5HO
Three Foot Lengths
21*▲ F21T5
25
F25T8
Four Foot Lengths
28
F28T5
32
F32T8
54
F54T5HO
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Options
HGO**Hospital Grade Grounded Outlet –
20A, 125V
GFI** Ground Fault Outlet
EL
One-Lamp (Downlight) Emergency
Battery Pack (32ºF) (120/277V only)
RF
Radio Frequency Filter (1 per circuit)
(120/277V only)
FS
Fuse & Holder (1 per circuit)
PCL
PCR
SW
TR
* 120/277 volts only.
■
Not available with EL options.
●
EL option not available.
▲
EL option not available with RF option.
** Not available in combination with EL, PC, or
SW options.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Pull Chain Left (2 position)(120V only)
Pull Chain Right (2 position)(120V only)
Rocker Switch (1 per circuit)
Tamper Resistant Posi-Grip Fastener
Residence™
MPWVT SERIES
PROJECT INFORMATION
Wall Mount–Surface
Ambient/Reading
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimension
Nominal 8" × 24", 8" × 36", 8" × 48"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Valance: Marine grade aluminum. Extruded
body and front face. Valance one-piece welded
construction. Housing/valance, post assembly
TGIC polyester powder coat – 5-stage pretreatment. Salt spray test: 1,000 hours. Standard
antimicrobial finish.
Housing: 18 gauge CRS baseplate provided
with four-point (24" housing) or six-point (36" and
48" housing) mounting holes and one wireway
hole. Removable gear tray slides into guide
channels; secured with two fasteners. Baseplate
and gear tray white TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours; Reflectance: 92%. Standard antimicrobial
finish.
Lens: U.V. stabilized, high impact resistant, clear
P12 acrylic. Smooth exterior, prismatic interior.
Nominal thickness .125". Lens securely positioned
in body channels.
Electrical: Fluorescent electronic
120/277/347V ballasts high power factor (<10%
THD). Circuits supplied with quick connects/
disconnects. One ballast per lamp compartment.
See Ordering Information for optional equipment.
Lamps by others.
Listings: UL and CUL Listed for Damp
Locations. Certified by independent lab to meet
OSHPD seismic loading standard. Pre-approved
by OSHPD for installation in California healthcare
facilities. Low Voltage Controller (LVC) option Pat.
No. D562,767.
Installation: Standard four-point (24" housing)
or six-point (36" and 48" housing) mounting.
DIMENSIONAL DATA
Cross SectionInstallation Details
(6) .281" Dia. Mounting Holes
with Embossed Standoffs
6.54"
(166mm)
8.00"
(203mm) 5.00"
(127mm)
8.00"
(203mm)
21.00
(533mm)
42.00
(1067mm)
50.30
(1277mm)
ORDERING INFORMATION
Series
Length
Finish
Lamp Config Lamp Type
Ballast Type
Voltage
Options
MPWVT
Nominal Length
24
2'
36
3'
48
4'
Finish
MW Matte White Antimicrobial (STD)
CC
Custom Color Antimicrobial (Consult Factory)
Lamp Configuration
22
2 Up 2 Down
21
2 Up 1 Down
12
1 Up 2 Down
11
1 Up 1 Down
Lamp Type
Two Foot Lengths
14▲ F14T5
17
F17T8
24▲ F24T5HO
Three Foot Lengths
21▲ F21T5
25
F25T8
Four Foot Lengths
28
F28T5
32
F32T8
54
F54T5HO
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Options
HGO Hospital Grade Grounded Outlet –
20A, 125V
EL*■▲² 500 Minimum Lumen Battery Pack
(90 Minutes, 32ºF Starting Temp)
PEL*●▲²1100 Minimum Lumen Battery Pack
(90 Minutes, 32ºF Starting Temp)
DB▲ Electronic Dimming Ballast
(Ambient Lamps)
RF▲ Radio Frequency Filter (1 per circuit)
FS
Fuse & Holder (1 per circuit)
LN▲ Chart Light – White Light LED
TN▲² Chart Light – 5/7/9 Watt PL
PCC Pull Chain Center (4 position)(120V only)
PCL Pull Chain Left (4 position)(120V only)
PCR Pull Chain Right (4 position)(120V only)
LVC▲ Low Voltage Controller (See Technical
Sheet or consult factory for switching
options)
* Dry Location only (EL option). One lamp
maximum in emergency mode.
■
2' fixtures have minimum 390-650 lumen
battery pack. T5/T5HO not available with
both Chart Light Option AND Low Voltage
Controller option.
●
Not available on 2' fixtures. 3' fixtures have
minimum 750-1100 lumen battery pack.
Not available with both Chart Light Option
AND Low Voltage Controller option.
▲
120/277V only.
² Not available with 2 T5HO lamps down.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
59
59
Residence™
MPWVC SERIES
PROJECT INFORMATION
Wall Mount–Surface
Ambient/Reading
Lamps: T5, T8, T5HO
Antimicrobial Finish Standard
Job Name
Dimension
Nominal 8" × 24", 8" × 36", 8" × 48"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Valance: Marine grade aluminum. Extruded
body and front face. Valance one-piece welded
construction. Housing/valance, post assembly
TGIC polyester powder coat – 5-stage pretreatment. Salt spray test: 1,000 hours. Standard
antimicrobial finish.
Housing: 18 gauge CRS baseplate provided
with four-point (24" housing) or six-point (36" and
48" housing) mounting holes and one wireway
hole. Removable gear tray slides into guide
channels; secured with two fasteners. Baseplate
and gear tray white TGIC polyester powder coat
– 5-stage pre-treatment. Salt spray test: 1,000
hours; Reflectance: 92%. Standard antimicrobial
finish.
Lens: U.V. stabilized, high impact resistant, clear
P12 acrylic. Smooth exterior, prismatic interior.
Nominal thickness .125". Lens securely positioned
in body channels.
Electrical: Fluorescent electronic
120/277/347V ballasts high power factor (<10%
THD). Circuits supplied with quick connects/
disconnects. One ballast per lamp compartment.
See Ordering Information for optional equipment.
Lamps by others.
Listings: UL and CUL Listed for Damp
Locations. Certified by independent lab to meet
OSHPD seismic loading standard. Pre-approved
by OSHPD for installation in California healthcare
facilities. Low Voltage Controller (LVC) option Pat.
No. D562,767.
Installation: Standard four-point (24" housing)
or six-point (36" and 48" housing) mounting.
DIMENSIONAL DATA
Cross SectionInstallation Details
(6) .281" Dia. Mounting Holes
with Embossed Standoffs
6.54"
(166mm)
8.00"
(203mm) 5.00"
(127mm)
8.00"
(203mm)
21.00
(533mm)
42.00
(1067mm)
50.30
(1277mm)
ORDERING INFORMATION
Series
Length
Finish
Lamp Config Lamp Type
Ballast Type
Voltage
Options
MPWVC
Nominal Length
24
2'
36
3'
48
4'
Finish
MW Matte White Antimicrobial (STD)
CC
Custom Color Antimicrobial (Consult Factory)
Lamp Configuration
22
2 Up 2 Down
21
2 Up 1 Down
12
1 Up 2 Down
11
1 Up 1 Down
60
Lamp Type
Two Foot Lengths
14 ▲ F14T5
17
F17T8
24▲ F24T5HO
Three Foot Lengths
21▲ F21T5
25
F25T8
Four Foot Lengths
28
F28T5
32
F32T8
54
F54T5HO
Ballast Type
IS
Instant Start Electronic
<10% THD (T8)
RS
Rapid Start Electronic
<10% THD (T8,T5,T5HO)
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347 347 Volts
Options
HGO Hospital Grade Grounded Outlet –
20A, 125V
EL*■▲² 500 Minimum Lumen Battery Pack
(90 Minutes, 32ºF Starting Temp)
PEL*●▲²1100 Minimum Lumen Battery Pack
(90 Minutes, 32ºF Starting Temp)
DB▲ Electronic Dimming Ballast
(Ambient Lamps)
RF▲ Radio Frequency Filter (1 per circuit)
FS
Fuse & Holder (1 per circuit)
LN▲ Chart Light – White Light LED
TN▲² Chart Light – 5/7/9 Watt PL
PCC Pull Chain Center (4 position)(120V only)
PCL Pull Chain Left (4 position)(120V only)
PCR Pull Chain Right (4 position)(120V only
LVC▲ Low Voltage Controller (See Technical
Sheet or consult factory for switching
options)
* Dry Location only (EL option). One lamp
maximum in emergency mode.
■
2' fixtures have minimum 390-650 lumen
battery pack. T5/T5HO not available with
both Chart Light option AND Low Voltage
Controller option.
●
Not available on 2' fixtures. 3' fixtures have
minimum 750–1100 lumen battery pack. Not
available with both Chart Light option AND
Low Voltage Controller option.
▲
120/277V only.
² Not available with 2 T5HO lamps down.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
SoftStep™
MSL SERIES
PROJECT INFORMATION
Low Wall–Recessed
Lamps: LED, CFL
Antimicrobial Finish Standard with
Gloss White Faceplate Finish
Job Name
Dimension
Nominal 3" × 9"
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 18 gauge CRS. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Four .875"
knockouts. Antimicrobial finish standard with
Gloss White Faceplate Finish.
Faceplate: 18 gauge CRS (powder coated)
or Type 304 Brushed Stainless Steel. Faceplate
secured to housing with torsion springs or
stainless steel screws. Internal louver is positioned behind lens for easy cleaning of entire
faceplate.
Lens: Optional polycarbonate, acrylic or tempered glass lens. Polycarbonate and acrylic lens
available in clear, prismatic or translucent white.
Tempered glass available in clear or prismatic.
Electrical: 120/277 dual voltage LED technology. Input power .49 watts @ .0484 amps. Available in white, red, amber and blue. LED option
includes field adjustable light level control. Factory
pre-set at 100%; 40-100% lumen output adjustable only at time of installation or maintenance.
Fluorescent magnetic ballast normal power factor.
Installation: Two adjustable mounting brackets for new construction. For existing construction, order RB accessory.
Listings: UL and CUL Listed for Damp Locations.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
Wall Thickness
Range 5/8"-1 1/4"
4.25"
(108mm)
3.75"
(95mm)
3.50"
(89mm)
3.12"
.30"
(8mm) (79mm)
9.25"
(235mm)
ORDERING INFORMATION
Series
Faceplate
Faceplate Mtrl Faceplate Finish Lens
Lamp Type
Voltage
Fasteners
Accessory
Packaging
MSL
Faceplate
F ▲
Full Face
S▲
Slotted
L*
Internal Louver
Faceplate Material
0
18 Gauge CRS (Painted)
1
18 Gauge Type 304 SS Brushed
Faceplate Finish
BSS Brushed SS
GW Gloss White Antimicrobial
MW Matte White
MB Matte Black
DB
Dark Bronze
WS Warm Satin Painted Anodized
CS
Cool Satin Painted Anodized
LG
Grey
IV
Ivory
Lens
Polycarbonate
CP* Clear
PP
Pearlescent
2
.125" #12 Prismatic
Acrylic
T*
.125" Clear High Impact
PIA Pearlescent
U
.125" #12 Prismatic High Impact
Tempered Glass
8*
.187" Clear
R
.156" C73 Prismatic
Lamp Type
Low Lumen
WLL White Low Lumen LED
RLL Red LED
BLL Blue LED
ALL Amber LED
High Lumen
5
5 Watt Twin
7
7 Watt Twin
9
9 Watt Twin
WHL White High Lumen LED
Voltage
120 120 Volts
277 277 Volts
Packaging
SP** Split Packaging (min. quantity 10 pcs)
▲
Not available with clear lens options.
* Internal Louver (L) available with clear lens
option only.
• Available with Fluorescent lamps only.
** Rough-In Box (Box 1), Fixture Section (Box 2)
Fasteners
1•
Torsion Springs
2
Torx Head w/Center pin (2)
3
Philips Head Fasteners (2)
Accessory
RB
Retrofit Mounting Brackets
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
61
61
SoftStep™
MSLD SERIES
PROJECT INFORMATION
Low Wall–Recessed
duplex outlet version
Lamps: LED, CFL
Antimicrobial Finish Standard with
Gloss White Faceplate Finish
Job Name
Fixture Type
Dimension
Nominal 6" × 9"
Catalog Number Approved by
SPECIFICATIONS
Housing: 18 gauge CRS. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Three .875"
knockouts. Antimicrobial finish standard with
Gloss White Faceplate Finish.
Faceplate: 18 gauge CRS (powder coated)
or Type 304 Brushed Stainless Steel. Faceplate
secured to housing with torsion springs or
stainless steel screws. Internal louver is positioned behind lens for easy cleaning of entire
faceplate.
Lens: Optional polycarbonate, acrylic or tempered glass lens. Polycarbonate and acrylic lens
available in clear, prismatic or translucent white.
Tempered glass available in clear or prismatic.
Electrical: 120/277 dual voltage LED technology. Input power .49 watts @ .0484 amps. Available in white, red, amber and blue. LED option
includes field adjustable light level control. Factory
pre-set at 100%; 40-100% lumen output adjustable only at time of installation or maintenance.
Fluorescent magnetic ballast normal power factor.
20A hospital grade duplex outlet available in 2
standard colors. Optional colors available – consult
factory for grey, brown, red, and black.
Installation: Two adjustable mounting brackets for new construction. For existing construction, order RB accessory.
Listings: UL and CUL Listed for Dry Locations.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
Wall Thickness
Range 5/8"-1 1/4"
7.00"
(178mm)
6.50"
(165mm)
6.25"
(159mm)
9.25"
(235mm)
3.12"
.30"
(8mm) (79mm)
ORDERING INFORMATION
Series
Faceplate
Faceplate Mtrl Faceplate Finish Outlet Color
Lens
Lamp Type
MSLD
Fasteners
Accessory
Packaging
120
Faceplate
F▲
Full Face
S▲
Slotted
L*
Internal Louver
Faceplate Material
0
18 Gauge CRS (Painted)
1
18 Gauge Type 304 SS Brushed
Faceplate Finish
BSS Brushed SS
GW Gloss White Antimicrobial
MW Matte White
MB Matte Black
DB
Dark Bronze
WS Warm Satin Painted Anodized
CS
Cool Satin Painted Anodized
LG
Grey
IV
Ivory
62
Voltage
Outlet Color
W
White (STD)
I
Ivory (STD)
Lens
Polycarbonate
CP* Clear
PP
Pearlescent
2
.125" #12 Prismatic
Acrylic
T*
.125" Clear High Impact
PIA Pearlescent
U
.125" #12 Prismatic High Impact
Tempered Glass
8*
.187" Clear
R
.156" C73 Prismatic
Lamp Type
Low Lumen
WLL White Low Lumen LED
RLL Red LED
BLL Blue LED
ALL Amber LED
High Lumen
5
5 Watt Twin
7
7 Watt Twin
9
9 Watt Twin
WHL White High Lumen LED
Accessory
RB
Retrofit Mounting Brackets
Packaging
SP** Split Packaging (min. quantity 8 pcs)
▲
Not available with clear lens options.
* Internal Louver (L) available with clear lens
option only.
• Available with Fluorescent lamps only.
** Rough-In Box (Box 1), Fixture Section (Box 2)
Voltage
120 120 Volts
Fasteners
1•
Torsion Springs
2
Torx Head w/Center pin (4)
3
Philips Head Fasteners (4)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
SoftStep™
MSLT SERIES
PROJECT INFORMATION
Low Wall–Recessed
Through Wall Version
Lamps: LED, CFL
Antimicrobial Finish Standard with
Gloss White Faceplate Finish
Job Name
Fixture Type
Dimension
Nominal 5" × 9"
Catalog Number Approved by
SPECIFICATIONS
Housing: 18 gauge CRS. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Four .875"
knockouts. Antimicrobial finish standard with
Gloss White Faceplate Finish.
Faceplate: 18 gauge CRS (powder coated)
or Type 304 Brushed Stainless Steel. Faceplate
secured to housing with stainless steel screws.
Internal louver is positioned behind lens for easy
cleaning of entire faceplate.
Lens: Optional polycarbonate, acrylic or tempered glass lens. Polycarbonate and acrylic lens
available in clear, prismatic or translucent white.
Tempered glass available in clear or prismatic.
Electrical: 120/277 dual voltage LED technology. Input power .49 watts @ .0484 amps. Available in white, red, amber and blue. LED option
includes field adjustable light level control. Factory
pre-set at 100%; 40-100% lumen output adjustable only at time of installation or maintenance.
Fluorescent magnetic ballast normal power factor.
Installation: Two adjustable mounting
brackets.
Listings: UL and CUL Listed for Damp Locations.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
Wall Thickness
Range 1/2"-7/8"
5.75"
(146mm)
.30"
(8mm)
5.25"
(133mm)
Outside Wall to Wall
Range 4 5/8"-5 3/8"
9.25"
(235mm)
ORDERING INFORMATION
Series
Faceplate
Faceplate Mtrl Faceplate Finish Lens
Lamp Type
Voltage
Fasteners
MSLT
Faceplate
F▲
Full Face
S▲
Slotted
L*
Internal Louver
Faceplate Material
0
18 Gauge CRS (Painted)
1
18 Gauge Type 304 SS Brushed
Faceplate Finish
BSS Brushed SS
GW Gloss White Antimicrobial
MW Matte White
MB Matte Black
DB
Dark Bronze
WS Warm Satin Painted Anodized
CS
Cool Satin Painted Anodized
LG
Grey
IV
Ivory
Lens
Polycarbonate
CP* Clear
PP
Pearlescent
2
.125" #12 Prismatic
Acrylic
T*
.125" Clear High Impact
PIA Pearlescent
U
.125" #12 Prismatic High Impact
Tempered Glass
8*
.187" Clear
R
.156" C73 Prismatic
Lamp Type
Low Lumen
WLL White Low Lumen LED
RLL Red LED
BLL Blue LED
ALL Amber LED
High Lumen
5
5 Watt Twin
7
7 Watt Twin
9
9 Watt Twin
Fasteners
2
Torx Head w/Center pin (2)
3
Philips Head Fasteners (2)
▲
Not available with clear lens options.
* Internal Louver (L) available with clear lens
option only.
Voltage
120 120 Volts
277 277 Volts
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
63
63
MedMaster™
M2SESI14 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
Job Name
Dimension
Nominal 1' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing.
located in symmetric reflector area (see Cross
Section on back).
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Installation: Four .312" holes for surface
mounting.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Green phosphor lamp (GL Option)
DIMENSIONAL DATA
Cross SectionGasket ProfileMounting Holes
Housing
10.60"
(269mm)
S
5.00"
(127mm)
(4) .312 (8mm) Mounting Holes
Fixture
Housing
Lens Frame
10.60"
(269mm)
Gasket
2.00"
(51mm)
36.00"
(914mm)
49.38"
(1254mm)
10.20" x 48.97"
(259mm x 1244mm)
Lens Frame
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2
VARIABLE LEVEL (DIMMING)
(2) T8 Lamps
(1) 2 lamp ballast with (2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(1) T8 Lamp +N/A
(1) 1 lamp + (1) 1 lamp ballast
(1) 1 lamp dimming ballast + (1) 1 lamp
(1) T8 Green
(green) with (2) RFI filters
ballast (green) with (2) RFI filters
(2) T5HO Lamps (1) 2 lamp ballast with (2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(2) T8 Lamps
(1) 2 lamp ballast with (2) 1 lamp ballasts withN/A
Magnetic
(1) RFI filter
(2) RFI filters
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Housing Opt
Lens Options
Other Options
Accessory
M2SESI14
Lamp Qty
2
Two
1/1 One White/One Green
Lamp Type
28
F28T5
32 F32T8
32/36 One White/One Green
54
F54T5HO
64
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Lighting Levels*
1
One
2
Two
D†
Dimmable
Housing Options
2H
18 Ga CRS (STD)
5H
18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
GL
Green Phosphor Lamp (36W T8, 550nm
only, 1 lamp included)
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
*
†
See chart above for ballast and RFI
information
If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M2SESI22 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface
Operating Room Inset Door
Lamps: T5, T8, T5HO, Biaxial
Patents Pending
Job Name
Dimension
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing.
Installation: Four .312" holes for surface
mounting.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Light direction reflectors are field
changeable.
DIMENSIONAL DATA
Cross SectionGasket ProfileMounting Holes
(4) .312 (8mm) Mounting Holes
Housing
22.60"
(574mm)
Fixture
Housing
5.00"
(127mm)
Lens Frame
Gasket
12.00"
22.60" (305mm)
(574mm)
22.20" x 23.72"
(564mm x 602mm)
Lens Frame
12.00:"
(305mm)
24.12"
(613mm)
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with
(2) 3 lamp ballasts with (3) 2 lamp ballasts with (2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with
(2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T5HO Lamps
(2) 2 lamp ballasts with
(2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with
(3) 2 lamp ballasts with (3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Housing Opt
Lens Options
Other Options
M2SESI22
Lamp Qty
2
Two
3
Three
4
Four
6
Six
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(CFL,T8,T5,T5HO)
DM7 Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Lamp Type
14
F14T5
17
F17T8
24
F24T5HO (4 Lamp Max.)
55B F55TT (Biax) (3 Lamp Max.)
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D
Dimmable
Housing Options
2H
18 Ga CRS (STD)
5H
18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RFI
Additional RFI filter (1)
* See chart above for ballast and RFI
information
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
65
65
MedMaster™
M2SESI24 SERIES
PROJECT INFORMATION
Ceiling Mount–Surface
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
Job Name
Dimension
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing.
located in symmetric reflector area (see Cross
Section on back). Light direction reflectors are
field changeable.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Installation: Four .312" holes for surface
mounting.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Green phosphor lamps (GL Option)
DIMENSIONAL DATA
Cross SectionGasket ProfileMounting Holes
(4) .312 (8mm) Mounting Holes
Housing
22.60"
(574mm)
S
5.00"
(127mm)
Fixture
Housing
S
Lens Frame
Gasket
12.00"
22.60" (305mm)
(574mm)
22.20" x 47.72"
(564mm x 1212mm)
Lens Frame
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
36.00"
(914mm)
48.12"
(1222mm)
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with (2) 3 lamp ballasts with
(3) 2 lamp ballasts with
(2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T8 Lamps +N/A
(2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp dimming ballasts + (1) 2
(2) T8 Green
(green) with (2) RFI filters
(green) with (3) RFI filters
lamp ballast (green) with (3) RFI filters
(4) T5HO Lamps (2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with (3) 2 lamp ballasts with
(3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Housing Opt
Lens Options
Other Options
Accessory
M2SESI24
Lamp Qty
4
Four
6
Six
4/2 Four White/Two Green
Lamp Type
28
F28T5
32 F32T8
32/36 Four White/Two Green
54
F54T5HO (4 Lamp Max.)
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D†
Dimmable
Housing Options
2H
18 Ga CRS (STD)
5H
18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
66
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
GL
Green Phosphor Lamps (36W T8, 550nm
only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
* See chart above for ballast and RFI
information
† If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M2SEGI14 SERIES
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-bar
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 1' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Green phosphor lamp (GL Option)
located in symmetric reflector area (see Cross
Section on back).
Installation: 1.0” and 1.5” T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-bar
ceilings.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket ProfileT-Bar Interface
Housing
10.60"
(269mm)
Fixture
Housing
S
5.00"
(127mm)
2.16"
Housing
48.00" x 22.60"
.75"
(1219mm x 574mm)
T-Bar Grid
Lens Frame
Gasket
10.20" x 46.20"
(259mm x 1173mm)
Lens Frame
11.75" x 47.75"
(298mm x 1213mm)
Flange
Housing
46.59" x 22.60"
(1183mm x 574mm)
Flange
47.75" x 23.75"
(1213mm x 603mm)
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2
VARIABLE LEVEL (DIMMING)
(2) T8 Lamps
(1) 2 lamp ballast with (2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(1) T8 Lamp +N/A
(1) 1 lamp + (1) 1 lamp ballast
(1) 1 lamp dimming ballast + (1) 1 lamp
(1) T8 Green
(green) with (2) RFI filters
ballast (green) with (2) RFI filters
(2) T5HO Lamps (1) 2 lamp ballast with (2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(2) T8 Lamps
(1) 2 lamp ballast with (2) 1 lamp ballasts withN/A
Magnetic
(1) RFI filter
(2) RFI filters
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
Accessory
M2SEGI14
Lamp Qty
2
Two
1/1 One White/One Green
Lighting Levels*
1
One
2
Two
D† Dimmable
Lamp Type
28
F28T5
32 F32T8
32/36 One White/One Green
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
* See chart above for ballast and RFI
information
† If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
EC
Earthquake Clips
TC
T-Bar Clips
GL
Green Phosphor Lamp (36W T8, 550nm
only, 1 lamp included)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
67
67
MedMaster™
M2SEGI22 SERIES
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-bar
Operating Room Inset Door
Lamps: T5, T8, T5HO, Biaxial
Patents Pending
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 2' × 2'
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Light direction reflectors are field
changeable.
Installation: 1.0” and 1.5” T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-bar
ceilings.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket ProfileT-Bar Interface
Housing
22.60"
(574mm)
Fixture
Housing
5.37"
(136mm)
Housing
24.00"
(610mm)
T-Bar Grid
Max. 1.5"
Lens Frame
22.20" x 22.20"
(564mm x 564mm)
Lens Frame
23.75" x 23.75"
(603mm x 603mm)
Flange
Gasket
22.60"
(574mm)
Flange
23.75"
(603mm)
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with (2) 3 lamp ballasts with
(3) 2 lamp ballasts with (2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T5HO Lamps (2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with (3) 2 lamp ballasts with
(3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
M2SEGI22
68
Lamp Qty
2
Two
3
Three
4
Four
6
Six
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(CFL,T8,T5,T5HO)
DM7 Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Lamp Type
14
F14T5
17
F17T8
24
F24T5HO (4 Lamp Max.)
55B F55TT (Biax) (3 Lamp Max.)
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D
Dimmable
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
EC
Earthquake Clips
TC
T-Bar Clips
RFI
Additional RFI filter (1)
* See chart above for ballast and RFI
information
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M2SEGI24 SERIES
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-bar
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 2' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Green phosphor lamps (GL Option)
located in symmetric reflector area (see Cross
Section on back). Light direction reflectors are
field changeable.
Installation: 1.0” and 1.5” T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-bar
ceilings.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket ProfileT-Bar Interface
Housing
22.60"
(574mm)
S
5.37"
(136mm)
Fixture
Housing
S
T-Bar Grid
Max. 1.5"
Lens Frame
22.20" x 46.20"
(564mm x 1173mm)
Lens Frame
23.75" x 47.75"
(603mm x 1213mm)
Flange
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
ORDERING INFORMATION
Series
Housing
48.00"
(1219mm)
Lamp Qty
Gasket
46.60"
(1184mm)
Flange
47.75"
(1213mm)
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with (2) 3 lamp ballasts with
(3) 2 lamp ballasts with
(2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T8 Lamps +N/A
(2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp dimming ballasts + (1) 2
(2) T8 Green
(green) with (2) RFI filters
(green) with (3) RFI filters
lamp ballast (green) with (3) RFI filters
(4) T5HO Lamps (2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with (3) 2 lamp ballasts with
(3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
Accessory
M2SEGI24
Lamp Qty
4
Four
6
Six
4/2 Four White/Two Green
Lamp Type
28
F28T5
32 F32T8
32/36 Four White/Two Green
54
F54T5HO (4 Lamp Max.)
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D†
Dimmable
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F18 Ga Type 304 SS Brushed
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
EC
Earthquake Clips
TC
T-Bar Clips
GL
Green Phosphor Lamps (36W T8, 550nm
only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
* See chart above for ballast and RFI
information
† If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
69
69
MedMaster™
M2SEFI14 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Flange
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
Job Name
Dimension
Nominal 1' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Optics: Symmetric reflectors are CRS with a high
reflectance powder coated surface. Asymmetric
reflectors are premium 95% specular aluminum.
Green phosphor lamp (GL Option) located in symmetric reflector area (see Cross Section on back).
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Installation: Adjustable swing-out mounting
brackets.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket Profile
Fixture
Housing
S
5.01"
(127mm)
Recommended Ceiling Cutout
*10.875"
(276mm)
Gasket
Lens Frame
*49.625"
(1260mm)
10.60" x 49.38"
(269mm x 1254mm)
Housing
* Add .25" to each cut-out dimension when
Plaster Frame (PF) Option is specified.
11.75" x 50.53"
(298mm x 1283mm)
Flange
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2
VARIABLE LEVEL (DIMMING)
(2) T8 Lamps
(1) 2 lamp ballast with
(2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(1) T8 Lamp +N/A
(1) 1 lamp + (1) 1 lamp ballast (1) 1 lamp dimming ballast + (1) 1 lamp
(1) T8 Green
(green) with (2) RFI filters
ballast (green) with (2) RFI filters
(2) T5HO Lamps (1) 2 lamp ballast with
(2) 1 lamp ballasts with
(1) 2 lamp dimming ballast with
(1) RFI filter
(2) RFI filters
(1) RFI filter
(2) T8 Lamps
(1) 2 lamp ballast with
(2) 1 lamp ballasts withN/A
Magnetic
(1) RFI filter
(2) RFI filters
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
Accessory
M2SEFI14
Lamp Qty
2
Two
1/1 One White/One Green
Lamp Type
28
F28T5
32 F32T8
32/36 One White/One Green
54
F54T5HO
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
70
Lighting Levels*
1
One
2
Two
D†
Dimmable
Voltage
120 120 Volts
277 277 Volts
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
* See chart above for ballast and RFI
information
† If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RM Continuous Row Mounting
PF
Plaster Frame
GL
Green Phosphor Lamp (36W T8, 550nm
only, 1 lamp included)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M2SEFI22 SERIES
Ceiling Mount–Recessed Flange
Operating Room Inset Door
Lamps: T5, T8, T5HO, Biaxial
Patents Pending
PROJECT INFORMATION
Job Name
Dimension
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Light direction reflectors are field
changeable.
Installation: Adjustable swing-out mounting
brackets.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket Profile
Recommended Ceiling Cutout
Fixture
Housing
5.01"
(127mm)
Lens Frame
Gasket
*22.875"
(619mm)
22.60" x 24.12"
(574mm x 613mm)
Housing
*24.375"
(581mm)
23.75" x 25.27"
(603mm x 642mm)
Flange
* Add .25" to each cut-out dimension when Plaster
Frame (PF) Option is specified.
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with
(2) 3 lamp ballasts with
(3) 2 lamp ballasts with
(2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with
(2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T5HO Lamps (2) 2 lamp ballasts with
(2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with
(3) 2 lamp ballasts with
(3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
M2SEFI22
Lamp Qty
2
Two
3
Three
4
Four
6
Six
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(CFL,T8,T5,T5HO)
DM7 Low Voltage Electronic Dimming Ballast
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Lamp Type
14
F14T5
17
F17T8
24
F24T5HO (4 Lamp Max.)
55B F55TT (Biax) (3 Lamp Max.)
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D
Dimmable
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RM Continuous Row Mounting
PF
Plaster Frame
RFI
Additional RFI filter (1)
* See chart above for ballast and RFI
information
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
71
71
MedMaster™
M2SEFI24 SERIES
Ceiling Mount–Recessed Flange
Operating Room Inset Door
Lamps: T5, T8, T5HO
Patents Pending
PROJECT INFORMATION
Job Name
Dimension
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-Gauge CRS. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Housing Flange: 18-Gauge CRS. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame Gasket: One-piece closed cell
silicone gasket seals lens frame to housing and
ceiling structure.
Electrical: Electronic ballast <10% THD.
Programmed-Start, low voltage electronic dimming ballast (DM7) designed to operate T8 or
T5HO fluorescent lamps over a full range of light
output (100-3% T8; 100-1% T5HO). Minimum
Power Factor .98 for T5HO and .99 for T8. THD
at full light output 10%. Operates from compatible 0-10vdc controllers on Class 1 or Class 2 low
voltage systems. See Ordering Information for
alternate or multiple ballasts and optional equipment. Lamps by others. RFI suppressor standard
– one per circuit, one circuit standard.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Asymmetric reflectors are premium 95% specular
aluminum. Green phosphor lamps (GL Option)
located in symmetric reflector area (see Cross
Section on back). Light direction reflectors are
field changeable.
Installation: Adjustable swing-out mounting
brackets.
Listings: UL and CUL Listed for Wet Locations.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with electronic
and electronic dimming ballasts.
DIMENSIONAL DATA
Cross SectionGasket Profile
S
5.01"
(127mm)
Recommended Ceiling Cutout
Fixture
Housing
S
Lens Frame
Gasket
*22.875"
(581mm)
22.60" x 48.12"
(574mm x 1222mm)
Housing
*48.375"
(1229mm)
23.75" x 49.27"
(603mm x 1251mm)
Flange
NOTE: Green Phosphor Lamp located in Symmetric (S) Area
ORDERING INFORMATION
Series
Lamp Qty
* Add .25" to each cut-out dimension when
Plaster Frame (PF) Option is specified.
Lighting Levels – Ballast and RFI Information
LAMPSLEVEL 1LEVEL 2LEVEL 3
VARIABLE LEVEL (DIMMING)
(6) T8 Lamps
(2) 3 lamp ballasts with (2) 3 lamp ballasts with
(3) 2 lamp ballasts with
(2) 3 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(3) RFI filters
(2) RFI filters
(4) T8 Lamps
(2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(4) T8 Lamps +N/A
(2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp + (1) 2 lamp ballast (2) 2 lamp dimming ballasts + (1) 2
(2) T8 Green
(green) with (2) RFI filters
(green) with (3) RFI filters
lamp ballast (green) with (3) RFI filters
(4) T5HO Lamps (2) 2 lamp ballasts with (2) 2 lamp ballasts withN/A
(2) 2 lamp dimming ballasts with
(1) RFI filter
(2) RFI filters
(2) RFI filters
(6) T8 Lamps
(3) 2 lamp ballasts with (3) 2 lamp ballasts with
(3) 2 lamp ballasts withN/A
Magnetic
(2) RFI filters
(2) RFI filters
(3) RFI filters
Lamp Type Ballast Type Lighting Lvls*
Voltage
Door Frame Opt Hous/Flange Opt Lens Options
Other Options
Accessory
M2SEFI24
Lamp Qty
4
Four
6
Six
4/2 Four White/Two Green
Lamp Type
28
F28T5
32 F32T8
32/36 Four White/Two Green
54
F54T5HO (4 Lamp Max.)
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RS
Rapid Start Electronic <10% THD
(T8,T5,T5HO)
DM7† Low Voltage Electronic Dimming Ballast
72
Lighting Levels*
1
One (STD)
2
Two
3
Three (6 Lamps Only)
D†
Dimmable
Housing/Flange Options
2H
20 Ga CRS/18 Ga CRS (STD)
2H5 20 Ga CRS/18 Ga Type 304 SS
5H5 20 Ga Type 304 SS/18 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL
One-Lamp Indoor Battery Pack (32ºF)
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RM Continuous Row Mounting
PF
Plaster Frame
GL
Green Phosphor Lamps (36W T8, 550nm
only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2349Green Phosphor Lamp, 36W T8, 550nm
* See chart above for ballast and RFI
information
† If 32/36 lamp type is selected, green lamp
ballasts will not be dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M3SESI22 SERIES
Ceiling Mount–Surface
Operating Room Inset Door
Lamps: T5HO
Patents Pending
PROJECT INFORMATION
Job Name
Dimension
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Electrical: Electronic ballast <10% THD.
Standard with 3 two-lamp ballasts and 3 RFI suppressors. Lamps by others.
Installation: Four .312" holes for surface
mounting.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface.
DIMENSIONAL DATA
Cross SectionGasket ProfileMounting Holes
Housing
22.60" x 24.13"
(574mm x 613mm)
(4) .312 (8mm) Mounting Holes
Fixture
Housing
7.63"
(194mm)
Gasket
Lens Frame
12.00"
22.60" (305mm)
(574mm)
12.00"
(305mm)
24.13"
(613mm)
22.20" x 23.72"
(564mm x 602mm)
Lens Frame
ORDERING INFORMATION
Series
M3SESI22
Lamp Qty 6
Lamp Type
24
Ballast Type Voltage
Door Frame Opt
rs
Housing Opt
Lens Options
Other Options
PAH
Lamp Qty
6
Six
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing Option
PAH .050" Painted Aluminum
Lamp Type
24
F24T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RFI
Additional RFI filter (1)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
73
73
MedMaster™
M3SESI24 SERIES
Ceiling Mount–Surface
Operating Room Inset Door
Lamps: T5HO
Patents Pending
PROJECT INFORMATION
Job Name
Dimension
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Electrical: Electronic ballast <10% THD.
Standard with 4 two-lamp ballasts and 4 RFI suppressors. Lamps by others.
Installation: Four .312" holes for surface
mounting.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Green
phosphor lamps (GL Option) available.
DIMENSIONAL DATA
Cross SectionGasket ProfileMounting Holes
Housing
22.60" x 48.13"
(574mm x 1223mm)
(4) .312 (8mm) Mounting Holes
Fixture
Housing
7.63"
(194mm)
12.00"
22.60" (305mm)
(574mm)
Gasket
Lens Frame
36.00"
(914mm)
48.13"
(1223mm)
22.20" x 47.72"
(564mm x 1212mm)
Lens Frame
ORDERING INFORMATION
Series
Lamp Qty M3SESI24
8
Lamp Type
54
Ballast Type Voltage
Door Frame Opt
Housing Opt
rs
Lens Options
Other Options
Lamp Qty
8
Eight
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing Option
PAH .050" Painted Aluminum
Lamp Type
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL* Standard Lumen EL Pack
PEL* High Lumen EL Pack
SEL* Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
GL
Green Phosphor Lamps (54W T5HO,
550nm only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2468Green Phosphor Lamp (54W T5HO,
550nm)
* Remote mounted
74
Accessory
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M3SEGI22 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-bar
Operating Room Inset Door
Lamps: T5HO
Patents Pending
Job Name
Fixture Type
Dimension
Nominal 2' × 2'
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Housing flange: .050" aluminum. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Installation: 1.0" and 1.5" T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-bar
ceilings.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Electrical: Electronic ballast <10% THD.
Standard with 3 two-lamp ballasts and 3 RFI suppressors. Lamps by others.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface.
DIMENSIONAL DATA
Cross SectionGasket ProfileT-Bar Interface
Housing
22.60"
(574mm)
Housing
24.00"
(610mm)
Fixture
Housing
7.63"
(194mm)
T-Bar Grid
Max. 1.5"
Gasket
Lens Frame
22.60"
(574mm)
Flange
23.75"
(603mm)
22.20" x 22.20"
(564mm x 564mm)
Lens Frame
23.75" x 23.75"
(603mm x 603mm)
Flange
ORDERING INFORMATION
Series
M3SEGI22
Lamp Qty 6
Lamp Type
24
Ballast Type Voltage
Door Frame Opt
rs
Hous/Flange Opt
Lens Options
Other Options
PAH
Lamp Qty
6
Six
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing/Flange Option
PAH .050" Painted Aluminum
Lamp Type
24
F24T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
EC
Earthquake Clips
TC
T-Bar Clips
RFI
Additional RFI filter (1)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
75
75
MedMaster™
M3SEGI24 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-bar
Operating Room Inset Door
Lamps: T5HO
Patents Pending
Job Name
Fixture Type
Dimension
Nominal 2' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Housing flange: .050" aluminum. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Electrical: Electronic ballast <10% THD.
Standard with 4 two-lamp ballasts and 4 RFI suppressors. Lamps by others.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Green
phosphor lamps (GL Option) available.
Installation: 1.0" and 1.5" T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-bar
ceilings.
DIMENSIONAL DATA
Cross SectionGasket ProfileT-Bar Interface
Housing
22.60" x 48.13"
(574mm x 1222mm)
Housing
48.00"
(1219mm)
Fixture
Housing
7.63"
(194mm)
T-Bar Grid
Max. 1.5"
Gasket
Lens Frame
46.60"
(1184mm)
Flange
47.75"
(1213mm)
22.20" x 47.72"
(564mm x 1212mm)
Lens Frame
23.75" x 49.27"
(603mm x 1251mm)
Flange
ORDERING INFORMATION
Series
Lamp Qty M3SEGI24
8
Lamp Type
54
Ballast Type Voltage
Door Frame Opt
Hous/Flange Opt
rs
Lens Options
Other Options
Accessory
PAH
Lamp Qty
8
Eight
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing/Flange Option
PAH .050" Painted Aluminum
Lamp Type
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL* Standard Lumen EL Pack
PEL* High Lumen EL Pack
SEL* Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
EC
Earthquake Clips
TC
T-Bar Clips
GL
Green Phosphor Lamps (54W T5HO,
550nm only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2468Green Phosphor Lamp
(54W T5HO, 550nm)
* Adds 3" to height of fixture
76
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™
M3SEFI22 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Flange
Operating Room Inset Door
Lamps: T5HO
Patents Pending
Job Name
Dimension
Nominal 2' × 2'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Housing flange: .050" aluminum. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Electrical: Electronic ballast <10% THD.
Standard with 3 two-lamp ballasts and 3 RFI suppressors. Lamps by others.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface.
Installation: Adjustable swing-out mounting
brackets.
DIMENSIONAL DATA
Cross SectionGasket Profile
Recommended Ceiling Cutout
Fixture
Housing
7.66"
(195mm)
Lens Frame
22.875"
(619mm)
Gasket
24.375"
(581mm)
22.63" x 24.13"
(575mm x 613mm)
Housing
23.75" x 25.27"
(603mm x 642mm)
Flange
ORDERING INFORMATION
Series
M3SEFI22
Lamp Qty 6
Lamp Type
24
Ballast Type Voltage
Door Frame Opt
rs
Hous/Flange Opt
Lens Options
Other Options
PAH
Lamp Qty
6
Six
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing/Flange Option
PAH .050" Painted Aluminum
Lamp Type
24
F24T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RM Continuous Row Mounting
PF
Plaster Frame
RFI
Additional RFI filter (1)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
77
77
MedMaster™
M3SEFI24 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Flange
Operating Room Inset Door
Lamps: T5HO
Patents Pending
Job Name
Dimension
Nominal 2' × 4'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: .050" aluminum. Hole-free seam
welded construction. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Antimicrobial
finish standard.
Lens: Two piece design. Smooth lens exterior
is .125" clear acrylic, sealed to lens frame with
silicone sealant. Interior lens is .030" acrylic micro
linear prism, both lenses mechanically secured in
place. See options for alternate lens.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. UL Classified IP65. NSF2 – Splash Non-Food Zone. NSF49
– Pressurized Leakage Test.
Housing flange: .050" aluminum. Mitered
and welded corners then spot-welded to housing
before painting.
Lens Frame Gasket: One-piece closed cell extruded nitrile gasket seals lens frame to housing.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard with RS ballast.
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Antimicrobial finish standard. Lens frame secured
to housing with stainless steel aircraft cables
and captive flush mounted Phillips head stainless
steel fasteners.
Electrical: Electronic ballast <10% THD.
Standard with 4 two-lamp ballasts and 4 RFI suppressors. Lamps by others.
Optics: Symmetric reflectors are CRS with a
high reflectance powder coated surface. Green
phosphor lamps (GL Option) available.
Installation: Adjustable swing-out mounting
brackets.
DIMENSIONAL DATA
Cross SectionGasket Profile
Recommended Ceiling Cutout
Fixture
Housing
7.66"
(195mm)
Lens Frame
22.875"
(581mm)
Gasket
22.60" x 48.13"
(574mm x 1222mm)
Housing
48.375"
(1229mm)
23.75" x 49.27"
(603mm x 1251mm)
Flange
ORDERING INFORMATION
Series
Lamp Qty M3SEFI24
8
Lamp Type
54
Ballast Type Voltage
Door Frame Opt
rs
Hous/Flange Opt
Lens Options
Other Options
Accessory
PAH
Lamp Qty
8
Eight
Ballast Type
RS
Rapid Start Electronic <10% THD
Housing/Flange Option
PAH .050" Painted Aluminum
Lamp Type
54
F54T5HO
Voltage
120 120 Volts
277 277 Volts
Lens Options
MLP Micro Linear Prism (STD)
SL
Specified Lens
Door Frame Options
2F
18 Ga CRS Painted (STD)
AF
Anodized Aluminum
PAF Painted Fabricated Aluminum
5F
18 Ga Type 304 SS Brushed
Other Options
EL* Standard Lumen EL Pack
PEL* High Lumen EL Pack
SEL* Specified EL Pack
FS
Fuse & Holder
HJ
Sealed Wireway
HD
Hinged Door (w/o NSF listings)
RM Continuous Row Mounting
PF
Plaster Frame
GL
Green Phosphor Lamps (54W T5HO,
550nm only, 2 lamps included)
RFI
Additional RFI filter (1)
Accessory
C-2468Green Phosphor Lamp
(54W T5HO, 550nm)
* Adds 3" to height of fixture
78
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
M2DL6VL SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: LED
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Electronic LED driver. RFI suppressor standard. See Ordering Information for
optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.00”
(457mm)
3.47”
(88mm)
6.375”
(162mm)
Aperture
16.00”
(406mm)
1.375”
max ceiling
8.63”
(219mm)
21.48”
(546mm)
ORDERING INFORMATION
Series
Lamp Type
Color Temp
Voltage
Trim
m2dl6vl
Lamp Type
L22 22 Watt LED
L38 38 Watt LED
Color Temperature
35K 3500K
41K 4100K
Voltage
120 120 Volts
277 277 Volts
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
Polycarbonate
2
.125" #12 Prismatic
Specified Lens
SL Specified Lens
Other Options
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
DM Dimming
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
79
79
MedMaster™ Downlight
M2DL6VF SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: CFL
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). RFI suppressor standard. See Ordering Information for
optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
photometrics: Efficiency of M2DL6VF-1-32PRS-DV-2FW-PAH-CS-G = 52%; S/MH = 1.1,1.1.
For additional photometric information, go to
www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
16.13”
(410mm)
10.58”
(269mm)
16.13”
(410mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
19.60”
(498mm)
8.63”
(219mm)
ORDERING INFORMATION
Series
Lamp Qty
m2dl6vF
Lamp Type
Lamp Quantity
1
One
Lamp Type
13Q 13 Watt Quad
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
SB Specified Ballast
80
Ballast Type
Voltage
Trim
1
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
DV
120/277 Volts
347
347 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
M2DL6HF SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: CFL
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). RFI suppressor standard. See Ordering Information for
optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
photometrics: Efficiency of M2DL6HF-1-32PDV-2FW-PAH-CS-G = 58.9%; S/MH = 1.3,1.3.
For additional photometric information, go to
www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.12”
(460mm)
6.08”
(155mm)
17.00”
(432mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
8.63”
(219mm)
21.60”
(549mm)
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type
Ballast Type
Voltage
m2dl6HF
Trim
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
2
Two
Voltage
DV
120/277 Volts
347
347 Volts
Lamp Type
13Q 13 Watt Quad
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT (1 lamp only)
26P 26 Watt PLT (1 lamp only)
32P 32 Watt PLT (1 lamp only)
42P 42 Watt PLT (1 lamp only)
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
SB Specified Ballast
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
81
81
MedMaster™ Downlight
M2DL8VF SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: CFL
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). RFI suppressor standard. See Ordering Information for
optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
photometrics: Efficiency of M2DL8VF-1-32PRS-DV-2FW-PAH-CS-G = 59%; S/MH = 1.2,1.2.
For additional photometric information, go to
www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
16.13”
(410mm)
16.13”
(410mm)
12.58”
(318mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
19.60”
(498mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
m2dl8vF
Lamp Type
Lamp Quantity
1
One
Lamp Type
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
SB Specified Ballast
82
Ballast Type
Voltage
Trim
1
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
DV
120/277 Volts
347
347 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
M2DL8HF SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: CFL
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Fluorescent electronic 120/277V
ballasts high power factor (<10% THD). RFI suppressor standard. See Ordering Information for
optional equipment.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
photometrics: Efficiency of M2DL8HF-1-42PDV-2FW-PAH-CS-G = 69.4%; S/MH = 1.4,1.2.
For additional photometric information, go to
www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
21.87”
(556mm)
8.08”
(205mm)
17.00”
(432mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
25.35”
(549mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
Lamp Type
Ballast Type
Voltage
m2dl8HF
Trim
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
2
Two
Voltage
DV
120/277 Volts
347
347 Volts
Lamp Type
18Q 18 Watt Quad
26Q 26 Watt Quad
18P 18 Watt PLT
26P 26 Watt PLT
32P 32 Watt PLT
42P 42 Watt PLT
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
Ballast Type
RS Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
SB Specified Ballast
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Options
PAH
.050" Painted Aluminum
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
T
.125" Clear High Impact
UV UV Filtering (Specify)
Polycarbonate
2
.125" #12 Prismatic
G
.125" Clear
Specified Lens
SL Specified Lens
Other Options
EL
Standard Lumen EL Pack
PEL High Lumen EL Pack
SEL Specified EL Pack
FS Fuse & Holder
WW Single Wallwash
BB Black Baffle
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
83
83
MedMaster™ Downlight
M2DL6VI SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket. RFI suppressor standard.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
photometrics: Efficiency of M2DL6VI-1100A19-120-2FW-PAH-CS-8 = 47%; S/MH =
0.7,0.7. For additional photometric information, go
to www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
16.13”
(410mm)
10.58”
(269mm)
6.375”
(162mm)
Aperture
16.13”
(410mm)
17.91”
(455mm)
1.375”
max ceiling
19.60”
(498mm)
8.63”
(219mm)
ORDERING INFORMATION
Series
Lamp Qty
m2dl6vI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75P30S 75 Watt Incandescent (Par30S)
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
84
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
M2DL6HI SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 6 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 18-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket. RFI suppressor standard.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
photometrics: Efficiency of M2DL6HI-1100A19-120-2FW-PAH-CS-8 = 53.7%; S/MH =
1.3,1.2. For additional photometric information, go
to www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.12”
(460mm)
5.08”
(129mm)
6.375”
(162mm)
Aperture
17.00”
(432mm)
18.78”
(477mm)
1.375”
max ceiling
8.63”
(219mm)
21.60”
(549mm)
ORDERING INFORMATION
Series
m2dl6HI
Lamp Qty
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
18 Gauge CRS Flat White (STD)
18 Gauge CRS Flat Black
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
85
85
MedMaster™ Downlight
M2DL8VI SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
vertical lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket. RFI suppressor standard.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
photometrics: Efficiency of M2DL8VI-1100A19-120-2FW-PAH-CS-8 = 60%; S/MH =
0.8,0.8. For additional photometric information, go
to www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
16.13”
(410mm)
8.375”
(213mm)
Aperture
16.13”
(410mm)
17.91”
(455mm)
12.58”
(318mm)
1.375”
max ceiling
19.60”
(498mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
m2dl8vI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75P30S 75 Watt Incandescent (Par30S)
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
250P38 250 Watt Incandescent (Par38)
Hsg Options
Reflector Finish Lens Options
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
86
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Downlight
M2DL8HI SERIES for
surgical suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
Lamps: Incandescent
Job Name
Dimension
Nominal 8 3/8" Aperture
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: 16-gauge CRS. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test:
1,000 hours. Antimicrobial finish standard. Trim
secured to housing with captive flush mounted
Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket. RFI suppressor standard.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
photometrics: Efficiency of M2DL8HI-1200A21-120-2FW-PAH-CS-8 = 64.3%; S/MH =
0.7,1.1. For additional photometric information, go
to www.kenall.com.
Notes: Supplied with standard Antimicrobial Finish • MIL Spec 461E listing standard
Listings: UL and CUL Listed for through
branch circuit wiring. UL and CUL Listed for Wet
Location. UL Classified IP65. NSF2 – Splash
Non-Food Zone. NSF49 – Pressurized Leakage
Test. MIL-STD-461E – Air Force/Navy Fixed. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
21.87”
(556mm)
17.00”
(432mm)
18.78”
(477mm)
7.08”
(180mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
25.35”
(549mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
m2dl8HI
Lamp Qty
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
Hsg Options
Reflector Finish Lens Options
Other Options
PAH
Voltage
120
120 Volts (STD)
277
277 Volts
Trim
2FW
2FB
PAFW
PAFB
5BR
5FW
5FB
CC
16 Gauge CRS Flat White (STD)
16 Gauge CRS Flat Black
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Other Options
WW Single Wallwash
BB Black Baffle
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
Housing Options
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
87
87
MedMaster™ MRI Downlight
MriDL6VL SERIES for
MRI/Imaging suites
Ceiling Mount – Recessed
ambient
vertical lamp
100% NON-FERROUS CONSTRUCTION
Lamps: LED
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 6 3/8" Aperture
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
Electrical: Electronic LED driver. See Ordering
Information for optional equipment.
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
trim: .050" aluminum. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours. Antimicrobial finish standard.
Trim secured to housing with captive flush
mounted Phillips head stainless steel fasteners.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.00”
(457mm)
3.47”
(88mm)
6.375”
(162mm)
Aperture
16.00”
(406mm)
1.375”
max ceiling
8.63”
(219mm)
21.48”
(546mm)
ORDERING INFORMATION
Series
Lamp Type
Color Temp
Voltage
Trim
mRIdl6vl
Lamp Type
L22 22 Watt LED
L38 38 Watt LED
Color Temperature
35K 3500K
41K 4100K
Voltage
120 120 Volts
277 277 Volts
Hsg Options
Reflector Finish Lens Options
Trim
PAFW
PAFB
5BR
5FW
5FB
CC
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Housing Option
PAH
.050" Painted Aluminum
Lens Options
Acrylic
U
.125" #12 Prismatic High Impact
Polycarbonate
2
.125" #12 Prismatic
6
.187" #12 Prismatic
Tempered Glass
R
.156" C73 Prismatic
Specified Lens
SL Specified Lens
Other Options
WW Single Wallwash
BB Black Baffle
DM Dimming
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
88
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ MRI Downlight
MRIDL6VI SERIES for
MRI/Imaging suites
Ceiling Mount – Recessed
ambient
vertical lamp
100% NON-FERROUS CONSTRUCTION
Lamps: Incandescent
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 6 3/8" Aperture
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: .050" aluminum. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours. Antimicrobial finish standard.
Trim secured to housing with captive flush
mounted Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MRIDL6VI-1100A19-120-PAFW-PAH-CS-8 = 47%; S/MH =
0.7,0.7. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
16.13”
(410mm)
10.58”
(269mm)
16.13”
(410mm)
17.91”
(455mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
19.60”
(498mm)
8.63”
(219mm)
ORDERING INFORMATION
Series
mRIdl6vI
Lamp Qty
Lamp Type
Voltage
Trim
1
Hsg Option
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
Lamp Type
75LV 75 Watt Incandescent (A21), 12V DC
75P30S 75 Watt Incandescent (Par30S)
100LV 100 Watt Incandescent (A21), 12V DC
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Voltage
12*
12 Volts (DC only)
120
120 Volts (STD)
277
277 Volts
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Trim
PAFW
PAFB
5BR
5FW
5FB
CC
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Other Options
WW Single Wallwash
BB Black Baffle
* Transformer and lamps by others.
Housing Option
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
89
89
MedMaster™ MRI Downlight
MRIDL6HI SERIES for
MRI/Imaging suites
Ceiling Mount – Recessed
ambient
horizontal lamp
100% NON-FERROUS CONSTRUCTION
Lamps: Incandescent
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 6 3/8" Aperture
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: .050" aluminum. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours. Antimicrobial finish standard.
Trim secured to housing with captive flush
mounted Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MRIDL6HI-1100A19-120-PAFW-PAH-CS-8 = 53.7%; S/MH =
1.3,1.2. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 8.125" Diameter
18.12”
(460mm)
5.08”
(129mm)
17.00”
(432mm)
18.78”
(477mm)
1.375”
max ceiling
6.375”
(162mm)
Aperture
8.63”
(219mm)
21.60”
(549mm)
ORDERING INFORMATION
Series
Lamp Qty
mRIdl6HI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75LV 75 Watt Incandescent (A21), 12V DC
100LV 100 Watt Incandescent (A21), 12V DC
100A19 100 Watt Incandescent (A19)
150A21 150 Watt Incandescent (A21)
Hsg Option
Reflector Finish Lens Options
Voltage
12*
12 Volts (DC only)
120
120 Volts (STD)
277
277 Volts
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Trim
PAFW
PAFB
5BR
5FW
5FB
CC
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
.050" Aluminum Flat White
.050" Aluminum Flat Black
18 Gauge Type 304 SS Brushed
18 Gauge Type 304 SS Flat White
18 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Other Options
WW Single Wallwash
BB Black Baffle
* Transformer and lamps by others.
Housing Option
PAH
.050" Painted Aluminum
90
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ MRI Downlight
MRIDL8VI SERIES for
MRI/Imaging suites
Ceiling Mount – Recessed
ambient
vertical lamp
100% NON-FERROUS CONSTRUCTION
Lamps: Incandescent
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 8 3/8" Aperture
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
trim: .063" aluminum. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours. Antimicrobial finish standard.
Trim secured to housing with captive flush
mounted Phillips head stainless steel fasteners.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MRIDL8VI-1100A19-120-PAFW-PAH-CS-8 = 60%; S/MH =
0.8,0.8. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
16.13”
(410mm)
16.13”
(410mm)
17.91”
(455mm)
12.58”
(318mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
19.60”
(498mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
mRIdl8vI
Lamp Qty
Lamp Type
Voltage
Trim
1
Hsg Option
Reflector Finish Lens Options
Other Options
PAH
Lamp Quantity
1
One
Lamp Type
75LV 75 Watt Incandescent (A21), 12V DC
75P30S 75 Watt Incandescent (Par30S)
100LV 100 Watt Incandescent (A21), 12V DC
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
250P38 250 Watt Incandescent (Par38)
Voltage
12*
12 Volts (DC only)
120
120 Volts (STD)
277
277 Volts
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Trim
PAFW
PAFB
5BR
5FW
5FB
CC
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Other Options
WW Single Wallwash
BB Black Baffle
* Transformer and lamps by others.
Housing Option
PAH
.050" Painted Aluminum
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
91
91
MedMaster™ MRI Downlight
MRIDL8HI SERIES for
MRI/Imaging suites
PROJECT INFORMATION
Ceiling Mount – Recessed
ambient
horizontal lamp
100% NON-FERROUS CONSTRUCTION
Lamps: Incandescent
Job Name
Fixture Type
Dimension
Nominal 8 3/8" Aperture
Catalog Number Approved by
SPECIFICATIONS
lens: Sealed to trim with continuous lens retention system. Smooth side out lens orientation.
Housing: .050" aluminum. Fully enclosed and
sealed. White TGIC polyester powder coat –
5-stage pre-treatment. Salt spray test: 1,000
hours. Antimicrobial finish standard.
Reflector: Aluminum with clear specular low
iridescent anodized finish. See Ordering Information for other finishes.
Electrical: Medium base shock absorbing
lamp socket.
photometrics: Efficiency of MRIDL8HI-1200A21-120-PAFW-PAH-CS-8 = 64.3%; S/MH =
0.7,1.1. For additional photometric information, go
to www.kenall.com.
Installation: Adjustable mounting brackets
for use with conduit or c-channel (by others).
Listings: UL and CUL Listed for through branch
circuit wiring. UL and CUL Listed for Wet Location. UL Classified IP65. NSF2 – Splash Non-Food
Zone. NSF49 – Pressurized Leakage Test. CCEA
Approved.
trim: .063" aluminum. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours. Antimicrobial finish standard.
Trim secured to housing with captive flush
mounted Phillips head stainless steel fasteners.
DIMENSIONAL DATA
Cross Sections
Recommended Ceiling Cutout: 10.125" Diameter
21.87”
(556mm)
17.00”
(432mm)
18.78”
(477mm)
7.08”
(180mm)
1.375”
max ceiling
8.375”
(213mm)
Aperture
25.35”
(549mm)
10.63”
(270mm)
ORDERING INFORMATION
Series
Lamp Qty
mRIdl8HI
Lamp Type
Voltage
Trim
1
Lamp Quantity
1
One
Lamp Type
75LV 75 Watt Incandescent (A21), 12V DC
100LV 100 Watt Incandescent (A21), 12V DC
100A19 100 Watt Incandescent (A19)
200A21 200 Watt Incandescent (A21)
Hsg Option
Reflector Finish Lens Options
Voltage
12*
12 Volts (DC only)
120
120 Volts (STD)
277
277 Volts
Reflector Finish
CS Clear Specular (STD)
CSS Clear Semi-Specular
CG Champagne Gold
Trim
PAFW
PAFB
5BR
5FW
5FB
CC
Lens Options
Tempered Glass
R
.156" C73 Prismatic
8
.187" Clear
Specified Lens
SL Specified Lens
.063" Aluminum Flat White
.063" Aluminum Flat Black
16 Gauge Type 304 SS Brushed
16 Gauge Type 304 SS Flat White
16 Gauge Type 304 SS Flat Black
Custom Color (Consult Factory)
Other Options
WW Single Wallwash
BB Black Baffle
* Transformer and lamps by others.
Housing Option
PAH
.050" Painted Aluminum
92
Other Options
PAH
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ Darkroom
MDRMS SERIES
PROJECT INFORMATION
Ceiling Mount–Surface
1, 2, and 3 COMPARTMENTS
Lamps: Incandescent
Job Name
Dimension
Nominal 1' x 1', 1' × 2', 1' x3'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Installation: Four .312" holes for surface
mounting.
Lens: C73 tempered glass standard.
Housing: 18-gauge CRS. Hole-free one-piece
seam welded construction. Black TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours.
Lens Frame Gasket: Silicone gasket seals
lens frame to housing.
Electrical: Maximum lamp wattage for filtered
Lens Frame: 18-gauge CRS. One-piece
compartment 15 watts. Maximum lamp wattage
10.60"
10.60"
10.60"
inset construction welded(269mm)
corners.
Black
TGIC
10.60"
10.60"
(269mm)
(269mm)
for C73 compartment
150 watts (A-21) (MDRMS2
(269mm)
(269mm)
polyester powder coat – 5-stage
pre-treatment.
and MDRMS3). Lamps by others. Prewired at fac6.00" 1,000 hours. Lens frame secured
Salt spray test:
6.00"
6.00"
6.00"
6.00"
(152mm)
tory(152mm)
for easy installation. Medium base porcelain
to housing(152mm)
with continuous hinge(152mm)
and captive
(152mm)
socket.
mounted Phillips head stainless steel fasteners.
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
DIMENSIONAL DATA
Cross Section / DetailsInstallation DetailsMounting Holes
10.60"
(269mm)
10.63"
10.63"
(270mm)
10.63"
(270mm)
(270mm)
10.63"
(270mm)
7.63"
7.63"
(194mm)
7.63"
(194mm)
(194mm)
10.63"
(270mm)
6.00"
(152mm)
10.60"
10.60"
10.60"
(269mm)
(269mm)
(269mm)
10.60"
(269mm)
(4) .312
Mounting Holes
6.00"
(152mm)
(4) .312
Mounting Holes
One Compartment
23.75"
23.75"
(603mm)
23.75"
(603mm)
(603mm)
23.75"
(603mm)
10.60"
(269mm)
6.00"
(152mm)
10.60"
10.60"
10.60"
(269mm)
(269mm)
(269mm)
10.60"
(269mm)
10.60"
(269mm)
Compartments
(269mm)
Compartments
1
One Compartment (15 Watt Max.)
2
Two Compartments
3
Three Compartments
(4) .312
Mounting Holes
6.00"
(152mm)
19.63"
(498mm)
(4) .312
Mounting Holes
19.63"
34.63"
(880mm)
3
(8
(4) .312
(4)
(4) .312
.312 Holes
Mounting
Mounting
Mounting Holes
Holes
6.00"
(152mm)
(4) .312
Mounting Holes
6.00"
(152mm)
(4) .312
Mounting Holes
31.63"
Three Compartments
(803mm)
34.63"
(880mm)
Filters
Options
120
Voltage
120 120 Volts
Filters
OC
I
1A
2
3
7B
13
GBX2
31.63"
(803mm)
(4) .312
Mounting Holes
6.00"
6.00"
6.00"
(152mm)
(152mm)
(152mm)
10.60"
(269mm)
Voltage
31.63"
31.63"
(803mm)
31.63"
(803mm)
(803mm)
34.63"
(880mm)
6.00"
(152mm)
MDRMS
6.00"
(152mm)
19.63"
(498mm)
(498mm)
Two Compartments
10.60"
(269mm)
ORDERING INFORMATION
(4) .312
(4)
(4) .312
.312 Holes
Mounting
Mounting
Mounting Holes
Holes
6.00"
6.00"
6.00"
(152mm)
(152mm)
(152mm)
10.60"
(269mm)
34.63"
34.63"
(880mm)
34.63"
(880mm)
(880mm)
10.60"
10.60"
10.60"
(269mm)
(269mm)
(269mm)
19.63"
19.63"
(498mm)
19.63"
(498mm)
(498mm)
23.75"
(603mm)
(4) .312
Mounting Holes
23.75"
(603mm)
10.60"
6.00"
(152mm)
7.63"
(194mm)
7.63"
(194mm)
10.63"
(270mm)
Series
(4) .312
(4)
(4) .312
.312 Holes
Mounting
Mounting
Mounting Holes
Holes
6.00"
6.00"
6.00"
(152mm)
(152mm)
(152mm)
10.60"
(269mm)
7.63"
(194mm)
(4) .312
6.00"
Mounting Holes
(152mm)Options
TP
FS
Tamper Proof
Fuse & Holder
Light Amber
Red
Light Red
Dark Red
Dark Green
Green
Amber
Red (Blue and Green Sensitive)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
93
93
MedMaster™ Darkroom
MDRMG SERIES
Ceiling Mount–Recessed Grid for
1.0" and 1.5" T-Bar
1, 2, and 3 COMPARTMENTS
Lamps: Incandescent
PROJECT INFORMATION
Job Name
Dimension
Nominal 1' x 1', 1' × 2', 1' x3'
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. Black TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours. Lens frame secured
6.00"
to housing with continuous hinge and captive(152mm)
mounted Phillips head stainless steel fasteners.
Installation: 1.0" and 1.5" T-Bar installation standard. See Options for T-Bar clips and
earthquake clips. Consult factory for custom T-Bar
ceilings.
Lens: C73 tempered glass standard.
Housing: 20-gauge CRS. Hole-free one-piece
seam welded construction. Black TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours.
Lens Frame Gasket: Silicone gasket seals
lens frame to housing.
Electrical: Maximum lamp wattage for filtered
11.75"
11.75"
(298mm)
(298mm)
compartment
15 watts.
11.75" Maximum lamp wattage
(298mm)
10.60"
10.60"
for C73 compartment
150 watts (A-21) (MDRMG2
(269mm)
(269mm)
10.60"
(269mm)by others. Prewired at facand MDRMG3). Lamps
6.00" for easy installation. Medium base porcelain
tory
6.00"
(152mm)
socket.
(152mm)
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
DIMENSIONAL DATA
Cross Section / DetailsInstallation Details
11.75"
(298mm)
11.75"
(298mm)
10.60"
(269mm)
6.00"
(152mm)
11.75"
(298mm)
11.75"
(298mm)
11.75"
(298mm)
23.75"
(603mm)
11.75"
11.75"
(298mm)
(298mm)
11.75"
(298mm)
One Compartment
11.75"
(298mm)
23.75"
(603mm)
35.75"
(908mm)
11.75"
(298mm)
11.75"
11.75"
(298mm)
(298mm)
Two Compartments
35.75"
(908mm)
35.75"
(908mm)
11.75"
(298mm)
11.75"
(298mm)
11.75"
11.75"
(298mm)
(298mm)
Three Compartments
35.75"
(908mm)
11.75"
ORDERING
INFORMATION
(298mm)
Series
Compartments
MDRMG
Compartments
1
One Compartment (15 Watt Max.)
2
Two Compartments
3
Three Compartments
94
Voltage
Filters
Options
120
Voltage
120 120 Volts
Filters
OC
I
1A
2
3
7B
13
GBX2
Light Amber
Red
Light Red
Dark Red
Dark Green
Green
Amber
Red (Blue and Green Sensitive)
Options
EC
Earthquake Clips
TC
T-Bar Clips
TP
Tamper Proof
FS
Fuse & Holder
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
23.75"
(603mm)
23.75"
(603mm)
MedMaster™ Darkroom
MDRMF SERIES
Ceiling Mount–Recessed Flange
1, 2, and 3 COMPARTMENTS
Lamps: Incandescent
Dimension
Nominal 1' x 1', 1' × 2', 1' x3'
PROJECT INFORMATION
Job Name
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-gauge CRS. Hole-free one-piece
seam welded construction. Black TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours.
to housing with continuous hinge and captive
mounted Phillips head stainless steel fasteners.
tory for easy installation. Medium base porcelain
socket.
Lens: C73 tempered glass standard.
Housing Flange: 20-gauge CRS. Mitered and
welded corners then spot-welded to housing.
Lens Frame Gasket: Silicone gasket seals
lens frame to housing.
Installation: Adjustable swing-out mounting
brackets standard.
10.60"
10.60"
(269mm)
(269mm)
10.60"
Maximum
(269mm)
Electrical:
lamp wattage for filtered
Lens Frame: 18-gauge CRS. One-piece
inset construction welded corners. Black TGIC 6.00"6.00" compartment 15 watts. Maximum lamp wattage
6.00" for C73 compartment 150 watts (A-21) (MDRMF2
(152mm)
(152mm)
polyester powder coat – 5-stage pre-treatment.
(152mm)
and
min.MDRMF3). Lamps by others. Prewired at fac1.50"1.50"
min.
Salt spray test: 1,000 hours. Lens frame secured 4.00"
1.50"
min.
4.00"
max.max.
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65.
4.00" max.
DIMENSIONAL DATA
Cross Section / DetailsInstallation Details
11.75"
11.75"
(298mm)
(298mm)
11.75"
(298mm)
10.60"
(269mm)
23.75"
23.75"
(603mm)
(603mm)
23.75"
(603mm)
6.00"
(152mm)
1.50" min.
4.00" max.
11.75"
11.75"
11.75"
(298mm)
(298mm)
(298mm)
11.75"
(298mm)
11.75"
11.75"
11.75"
(298mm)
(298mm)
(298mm)
23.75"
(603mm)
One Compartment:
Ceiling Cutout 10.875" x 10.875"
Two Compartments:
Ceiling Cutout 10.875" x 22.875"
35.75"
35.75"
(908mm)
(908mm)
35.75"
(908mm)
11.75"
(298mm)
11.75"
(298mm)
11.75"
11.75"
11.75"
(298mm)
(298mm)
(298mm)
35.75"
(908mm)
Three Compartments:
Ceiling Cutout 10.875" x 34.875"
11.75"
(298mm)
ORDERING INFORMATION
Series
Compartments
MDRMF
Compartments
1
One Compartment (15 Watt Max.)
2
Two Compartments
3
Three Compartments
Voltage
Filters
Options
120
Voltage
120 120 Volts
Filters
OC
I
1A
2
3
7B
13
GBX2
Options
TP
Tamper Proof
FS
Fuse & Holder
Light Amber
Red
Light Red
Dark Red
Dark Green
Green
Amber
Red (Blue and Green Sensitive)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
95
95
MedMaster™ CleanScene™
CS22 SERIES
PROJECT INFORMATION
Ceiling or wall Mount–
Surface/Grid/Flange
graphic image lightbox
Lamps: T5, T5HO
Antimicrobial Finish Standard
Job Name
Fixture Type
Dimension
Nominal 2' × 2'
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-gauge CRS. Hole-free one-piece
seam welded construction. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: 18-gauge CRS. One-piece inset
construction welded corners. White TGIC polyester powder coat – 5-stage pre-treatment. Salt
spray test: 1,000 hours; Reflectance: 92%. Lens
frame secured to housing with aircraft cables and
8 captive mounted Phillips head stainless steel
fasteners.
Lenses: .125" acrylic lens sealed to lens frame
with silicone sealant. .125" white acrylic diffuser
provides uniform surface illuminance. All lenses
secured with continuous lens retention system.
Lens Frame Gasket: Closed cell Neoprene/
EPDM/SBR gasket seals lens frame to housing.
Electrical: Electronic ballast <20% THD
standard. See Ordering Information for alternate
ballasts. Lamps by others.
Installation: Surface Mount: Four .312" diameter holes.Grid Mount: 1" or 1.5" T-Bar installation
standard. Includes hardware to secure hanger
wire. Flange Mount – Mounting yoke brackets
(standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65. NSF2 – Splash Non-Food
Zone.
DIMENSIONAL DATA
Cross Section
Recommended Ceiling Cutout
* 23.00" x 23.00"
(584mm x 584mm)
Housing
4.45"
(113mm)
** 23.25"
(590mm)
23.75" x 23.75"
(603mm x 603mm)
Flange
** 23.25"
(590mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified.
* Subtract .50" from housing width and length when 1.5" grid mounting
option is specified.
Fixture Configurations
A1
A9
A4
onfiguration SizeNumber of
C
Nominal Fixtures
A1
2' × 2'
1
A2
2' × 4'
2
A4
4' × 4'
4
A6
4' × 6'
6
A9
6' × 6'
9
Consult factory for alternate configuration requests.
A2
Graphic Image Size Needed – 2' × 2' Fixture
Surface (S)Grid 1.0" (G10)Grid 1.5" (G15)
21.00" × 21.00"
21.00" × 21.00"
20.50" × 20.50"
Flange (F, FW)
21.00" × 21.00"
A6
B1H
B3
ORDERING INFORMATION
Series
B1V
CS22
Mounting Opt
Config
Lamp Qty Lamp Type
Ballast Type Voltage
Frame Opt
Housing Opt
Mounting Options
S
Surface
G10 Grid (1")
G15 B2Grid (1.5")
F
Flange Ceiling
FW Flange Wall
Configuration (see above)
A1
One Square
A2
C1Two RectangleC4
A4
Four Square
A6
Six Rectangle
A9
Nine Square
SC C2Specified Configuration
(Consult Factory)
B4
Lamp Qty
4
Four Lamps
Lamp Type
14
F14T5 (n/a with DM10 ballast)
24* F24T5HO
Ballast Type
RS
Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
C9
DM10 Line Voltage Electronic Dimming Ballast
Frame Options
2F
18 Ga CRS Painted (STD)
5F
18 Ga Type 304 SS Brushed
PAF Painted Aluminum
Image
Housing Options
2H
20 Ga CRS (STD)
5H
20 Ga Type 304 SS
PAH .050" Painted Aluminum
Voltage
120 120 Volts
277 277 Volts
DV
120/277 Volts
Accessory
IF
Install Frame (Flange only)
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Consult factory for alternate image selection
approval.
* Available with DM10 ballast only.
C6
96
Accessory
4
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ CleanScene™
CS24 SERIES
PROJECT INFORMATION
Ceiling or wall Mount–
Surface/Grid/Flange
graphic image lightbox
Lamps: T5, T5HO
Antimicrobial Finish Standard
Job Name
Fixture Type
Dimension
Nominal 2' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: 20-gauge CRS. Hole-free one-piece
seam welded construction. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: 18-gauge CRS. One-piece inset
construction welded corners. White TGIC polyester powder coat – 5-stage pre-treatment. Salt
spray test: 1,000 hours; Reflectance: 92%. Lens
frame secured to housing with aircraft cables and
8 captive mounted Phillips head stainless steel
fasteners.
Lenses: .125" acrylic lens sealed to lens frame
with silicone sealant. .125" white acrylic diffuser
provides uniform surface illuminance. All lenses
secured with continuous lens retention system.
Grid Mount: 1" or 1.5" T-Bar installation standard.
Includes hardware to secure hanger wire.
Flange Mount – Mounting yoke brackets (standard): Fixture mounting hardware included.
Flange Mount – Install Frame (Accessory):
Positively locates yoke brackets within ceiling
opening; assures alignment of fixture. No measuring for yoke required; no drywall backing required
(included with frame assembly).
Lens Frame Gasket: Closed cell Neoprene/
EPDM/SBR gasket seals lens frame to housing.
Electrical: Electronic ballast <20% THD
standard. See Ordering Information for alternate
ballasts. Lamps by others.
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65. NSF2 – Splash Non-Food
Zone.
Installation: Surface Mount: Four .312"
diameter holes.
DIMENSIONAL DATA
Cross Section
A1
Recommended Ceiling Cutout
A4
* 23.00" x 47.00"
(584mm x 1194mm)
Housing
A9
4.45"
(113mm)
** 23.25"
(590mm)
A2
A6
23.75" x 47.75"
(603mm x 1213mm)
Flange
** 47.25"
(1200mm)
** Add .25" to each cut-out dimension when Install
Frame (IF) Accessory is specified.
* Subtract .50" from housing width and length when 1.5" grid mounting
option is specified.
Fixture Configurations
B1H
onfiguration SizeNumber of C
Nominal Fixtures
B1H/B1V
2' × 2'
1
B2
2' × 4'
2
B3
4' × 6'
3
B4
4' × 8'
4
Consult factory for alternate configuration requests.
B3
B1V
Graphic Image Size Needed – 2' × 4' Fixture
Surface (S)Grid 1.0" (G10)Grid 1.5" (G15)
21.00" × 45.00"
21.00" × 45.00"
20.50" × 44.50"
Flange (F, FW)
21.00" × 45.00"
B4
B2
ORDERING
INFORMATION
C1
C4
Series
Mounting Opt
Config
C9
Lamp Qty Lamp Type
Ballast Type Voltage
Frame Opt
Housing Opt
Accessory
Image
CS24
C2 Options
Mounting
S
Surface
G10 Grid (1")
C6
G15 Grid (1.5")
F
Flange Ceiling
FW Flange Wall
Lamp Qty
4
Four Lamps
Lamp Type
28
F28T5 (n/a with DM10 ballast)
54* F54T5HO
Configuration (see above)
B1H One Rectangle Horizontal
D3
B1V D1H
One Rectangle Vertical
B2
Two Square
B3
Three Rectangle
B4 D1V
Four Rectangle
SC
Specified Configuration
(Consult Factory)
Ballast Type
RS
Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
Voltage
120 120 Volts
277 277 Volts
DV
120/277 Volts
Frame Options
2F
18 Ga CRS Painted (STD)
5F
18 Ga Type 304 SS Brushed
PAF Painted Aluminum
Housing Options
2H
20 Ga CRS (STD)
5H
20 Ga Type 304 SS
PAH .050" Painted Aluminum
Accessory
IF
Install Frame (Flange only)
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Consult factory for alternate image selection
approval.
* Available with DM10 ballast only.
D4
D2
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
97
97
MedMaster™ CleanScene™
CS44 SERIES
PROJECT INFORMATION
Ceiling Mount–Recessed Grid
graphic image lightbox
Lamps: T5, T5HO
Antimicrobial Finish Standard
Patents Pending
Job Name
Fixture Type
Dimension
Nominal 4' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-gauge aluminum. Hole-free seam
welded construction. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens: Smooth, .177" acrylic lens sealed to lens
frame with high-strength acrylic adhesive.
Lens Frame: 18-gauge aluminum. One-piece
inset construction, welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Quick, one-person installation and removal of
lens frame for servicing of electrical components
and graphic image. Internal hinge design. Twelve
(12) captive mounted Phillips head stainless steel
fasteners.
Electrical: Electronic ballast <15% THD
standard. See Ordering Information for alternate
ballasts. 6500K fluorescent lamps recommended
for best image rendition (lamps by others).
Listings: UL and CUL Listed for Wet Locations.
UL Classified IP65. NSF2 – Splash Non-Food
Zone.
Lens Frame Gasket: Closed cell silicone
gasket seals lens frame to housing.
Installation: 1" or 1.5" T-Bar installation standard. Includes hardware to secure hanger wire.
DIMENSIONAL DATA
Cross Section
47.00" x 47.00"
(1194mm x 1194mm)
Housing
Subtract .50" from housing
width and length when 1.5"
grid mounting option is specified.
4.46"
(113mm)
47.75" x 47.75"
(1213mm x 1213mm)
Flange
Graphic Image Size Needed – 4' × 4' Fixture
Grid 1.0" (G10)Grid 1.5" (G15)
44.575" × 44.575"
44.075" × 44.075"
ORDERING INFORMATION
Series
Mounting Opt
CS44
Lamp Qty Lamp Type
Ballast Type Voltage
6
Frame Opt
Mounting Options
G10 Grid (1")
G15 Grid (1.5")
Lamp Type
28
F28T5 (n/a with DM10 ballast)
54* F54T5HO
Lamp Qty
6
Six Lamps
Ballast Type
RS
Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
Frame Option
PAF Painted Aluminum
Housing Option
PAH .050" Painted Aluminum
Other Options
FS
Fuse & Holder
RF
Radio Frequency Filter
Voltage
120 120 Volts
277 277 Volts
DV
120/277 Volts
98
Housing Opt
PAF
Other Opt
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Selected image must be marked for C4 or D2
usage. Consult factory for alternate image selection approval.
* Available with DM10 ballast only.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Image
PAH
MedMaster™ CleanScene™ Exam
CSMEC SERIES
Ceiling Mount–Recessed Grid
graphic image lightbox with
asymmetric exam compartments
Lamps: LED, T5, T5HO, Biaxial
Antimicrobial Finish Standard
Patents Pending
Dimension
Nominal 4' × 4'
PROJECT INFORMATION
Job Name
Fixture Type
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-gauge aluminum. Hole-free seam
welded construction. White TGIC polyester
powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%. Standard
antimicrobial finish.
Lens Frame: 18-gauge aluminum. One-piece
inset construction, welded corners. White TGIC
polyester powder coat – 5-stage pre-treatment.
Salt spray test: 1,000 hours; Reflectance: 92%.
Quick, one-person installation and removal of
lens frame for servicing of lamps and graphic
image. Internal hinge design. Twelve (12) captive
mounted Phillips head stainless steel fasteners.
Lenses: Smooth, .177" acrylic graphic lens/ .125"
acrylic exam lenses. Sealed to lens frame with
high-strength acrylic adhesive.
Lens Frame Gasket: Closed cell silicone
gasket seals lens frame to housing.
Electrical: Fluorescent, electronic 120/277V
ballasts, high power factor (<10% THD) standard.
Exam compartments available with two F54T5HO
or F55TT lamps per side. Graphic compartment
available with four T5/T5HO lamps or 6500K,
high-brightness LEDs. 6500K fluorescent lamps
recommended in graphic compartment for best
image rendition (lamps by others). LED System:
120/277V, high power factor driver (<20% THD);
input power 116 watts; dimming capability; internal feedback control ensures uniform light output
and longevity. Dimming control through compatible 0-10V dimmer (supplied by others).
Installation: 1" or 1.5" T-Bar installation standard. Includes hardware to secure hanger wire.
Listings: UL and CUL Listed for Wet Location.
UL Classified IP65. NSF2 – Splash Non-Food
Zone. LED lamps warranted for 50,000-hour life
based on 70% original lumen output.
DIMENSIONAL DATA
Cross Section
47.00" x 47.00"
(1194mm x 1194mm)
Housing
Subtract .50" from housing
width and length when 1.5"
grid mounting option is specified.
4.46"
(113mm)
47.75" x 47.75"
(1213mm x 1213mm)
Flange
Graphic Image Size Needed – 4' × 4' Fixture
Grid 1.0" (G10)Grid 1.5" (G15)
28.300" × 44.575"
27.800" × 44.075"
ORDERING INFORMATION
Series
Mounting Opt
Exam Lamp Type
Graphic Lamp Type
Graphic Ballast Type
Voltage
Options
Image
CSMEC
Mounting Options
G10 Grid (1")
G15 Grid (1.5")
Exam Lamp Type
54
F54T5HO
55B F55TT
Graphic Lamp Type
28
F28T5 (n/a with DM10 ballast)
54* F54T5HO
L116**116W HB White LED (6500K)
Graphic Ballast Type (N/A for LED)
RS
Rapid Start Electronic <10% THD
DM7 Low Voltage Electronic Dimming Ballast
DM10 Line Voltage Electronic Dimming Ballast
Voltage
120 120 Volts
277 277 Volts
Options
FS
Fuse & Holder (1 per circuit)
RF
Radio Frequency Filter (1 per circuit)
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Consult factory for alternate image selection
approval.
* Available with DM10 ballast only.
** Available with LED driver only. Enter "N/A" as
Graphic Ballast Type selection.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
99
99
MedMaster™ CleanScene™ MRI
CSMRI22 SERIES
Ceiling Mount–Recessed Grid
graphic image lightbox
Lamps: LED
Antimicrobial Finish Standard
Patents Pending
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 2' × 2'
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-gauge aluminum. Non-ferrous material content. Hole-free seam welded construction. White TGIC polyester powder coat – 5-stage
pre-treatment. Salt spray test: 1,000 hours;
Reflectance:
92%.
A9finish.
A1
A4Standard antimicrobial
Lens Frame: 18-gauge aluminum. Non-ferrous
material content. One-piece inset construction,
welded corners. White TGIC polyester powder
coatA2
– 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Quick, oneperson installation
A6and removal of lens frame for
servicing of electrical components and graphic
image. Internal hinge design. Eight (8) captive
mounted Phillips head stainless steel fasteners.
Lens: Smooth, .177" acrylic lens sealed to lens
frame with high-strength acrylic adhesive.
Lens Frame Gasket: Closed cell silicone
gasket seals lens frame to housing.
Electrical: High-brightness, 6500K white LED
light source; 120/230V, remote-mounted, high
power factor power supply; input power 48 watts;
dimming capability; internal feedback control
ensures uniform light output and longevity. Dimming control through compatible 0-10V dimmer
(supplied by others).
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. Independently tested for MRI suitability. UL Classified
IP65. NSF2 – Splash Non-Food Zone. LED lamps
warranted for 50,000-hour life based on 70%
original lumen output.
Installation: 1" or 1.5" T-Bar installation standard. Includes hardware to secure hanger wire.
DIMENSIONAL DATA
Cross
Section
B1H
B3
23.00" x 23.00"
(584mm x 584mm)
B1V
4.46"
(113mm)
Subtract .50" from housing
width and length when 1.5"
grid mounting option is specified.
B4
B2
23.75" x 23.75"
(603mm x 603mm)
Fixture Configurations
C1
onfiguration SizeNumber of
C
Nominal Fixtures
C1
2' × 2'
1
C2
2' × 4'
2
C4
4' × 4'
4
C6
4' × 6'
6
C8
6' × 6'
9
Consult factory for alternate configuration requests.
C9
C4
C2
Graphic Image Size Needed – 2' × 2' Fixture
Grid 1.0" (G10)Grid 1.5" (G15)
21.00" × 21.00"
20.50" × 20.50"
C6
D1H
D3
ORDERING
INFORMATION
D1V
Series
Mounting Opt
CSMRI22
Mounting Options
G10 D2Grid (1")
G15 Grid (1.5")
D4
Config
Lamp Type
L48
Voltage
Image
DV
Configuration (see above)
C1
One Square
C2
Two Rectangle
C4
Four Square
C6
Six Rectangle
C9
Nine Square
SC
Specified Configuration
(Consult Factory)
Voltage
DV
120/230 Volts
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Consult factory for alternate image selection
approval.
Lamp Type
L48 48W HB White LED (6500K)
100
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
MedMaster™ CleanScene™ MRI
CSMRI24 SERIES
A1
Ceiling Mount–Recessed Grid
graphic image lightbox
Lamps: LED
Antimicrobial Finish Standard
Patents Pending
Job Name
Fixture Type
Dimension
Nominal 2' × 4'
A9
A4
PROJECT INFORMATION
Catalog Number A2
Approved by
A6
SPECIFICATIONS
Housing: 18-gauge aluminum. Non-ferrous material content. Hole-free seam welded construction. White TGIC polyester powder coat – 5-stage
pre-treatment. Salt spray test: 1,000 hours;
B1H
B3antimicrobial finish.
Reflectance:
92%. Standard
Lens Frame: 18-gauge aluminum. Non-ferrous
material
B1V content. One-piece inset construction,
welded corners. White TGIC polyester powder
coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%.
B4 Quick, oneperson installation and removal of lens frame for
servicing
B2 of electrical components and graphic
image. Internal hinge design. Ten (10) captive
mounted Phillips head stainless steel fasteners.
Lens: Smooth, .177" acrylic lens sealed to lens
frame with high-strength acrylic adhesive.
Lens Frame Gasket: Closed cell silicone
gasket seals lens frame to housing.
Electrical: High-brightness, 6500K white LED
light source; 120/230V, remote-mounted, high
power factor power supply; input power 83 watts;
dimming capability; internal feedback control
ensures uniform light output and longevity. Dimming control through compatible 0-10V dimmer
(supplied by others).
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. Independently tested for MRI suitability. UL Classified
IP65. NSF2 – Splash Non-Food Zone. LED lamps
warranted for 50,000-hour life based on 70%
original lumen output.
Installation: 1" or 1.5" T-Bar installation standard. Includes hardware to secure hanger wire.
DIMENSIONAL DATA
Cross Section
C1
C4
C9
23.00" x 47.00"
(584mm x 1194mm)
Subtract .50" from housing
width and length when 1.5"
grid mounting option is specified.
C2
4.46"
(113mm)
C6
23.75" x 47.75"
(603mm x 1213mm)
Fixture Configurations
D1H
onfiguration SizeNumber of
C
Nominal Fixtures
D1H/D1V
2' × 2'
1
D2
2' × 4'
2
D3
4' × 6'
3
D4
4' × 8'
4
Consult factory for alternate configuration requests.
D3
D1V
Graphic Image Size Needed – 2' × 4' Fixture
Grid 1.0" (G10)Grid 1.5" (G15)
21.00" × 45.00"
20.50" × 44.50"
D4
D2
ORDERING INFORMATION
Series
CSMRI24
Mounting Options
G10 Grid (1")
G15 Grid (1.5")
Mounting Opt
Config
Lamp Type
Voltage
L83
Image
DV
Configuration (see pg 2)
D1H One Rectangle Horizontal
D1V One Rectangle Vertical
D2
Two Square
D3
Three Rectangle
D4
Four Rectangle
SC
Specified Configuration
(Consult Factory)
Voltage
DV
120/230 Volts
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Consult factory for alternate image selection
approval.
Lamp Type
L83 83W HB White LED (6500K)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
101
101
MedMaster™ CleanScene™ MRI
CSMRI44 SERIES
Ceiling Mount–Recessed Grid
graphic image lightbox
Lamps: LED
Antimicrobial Finish Standard
Patents Pending
PROJECT INFORMATION
Job Name
Fixture Type
Dimension
Nominal 4' × 4'
Catalog Number Approved by
SPECIFICATIONS
Housing: 18-gauge aluminum. Non-ferrous material content. Hole-free seam welded construction. White TGIC polyester powder coat – 5-stage
pre-treatment. Salt spray test: 1,000 hours;
Reflectance: 92%. Standard antimicrobial finish.
Lens: Smooth, .177" acrylic lens sealed to lens
frame with high-strength acrylic adhesive.
Lens Frame: 18-gauge aluminum. Non-ferrous
material content. One-piece inset construction,
welded corners. White TGIC polyester powder
coat – 5-stage pre-treatment. Salt spray test:
1,000 hours; Reflectance: 92%. Quick, oneperson installation and removal of lens frame for
servicing of electrical components and graphic
image. Internal hinge design. Twelve (12) captive
mounted Phillips head stainless steel fasteners.
Electrical: High-brightness, 6500K white
LED light source; 120/230V, remote-mounted,
high power factor power supply; input power
191 watts; dimming capability; internal feedback
control ensures uniform light output and longevity. Dimming control through compatible 0-10V
dimmer (supplied by others).
Lens Frame Gasket: Closed cell silicone
gasket seals lens frame to housing.
Listings: UL and CUL Listed for Wet Location.
MIL-STD-461E – Air Force/Navy Fixed. Independently tested for MRI suitability. UL Classified
IP65. NSF2 – Splash Non-Food Zone. LED lamps
warranted for 50,000-hour life based on 70%
original lumen output.
Installation: 1" or 1.5" T-Bar installation standard. Includes hardware to secure hanger wire.
DIMENSIONAL DATA
Cross Section
47.00" x 47.00"
(1194mm x 1194mm)
Housing
Subtract .50" from housing
width and length when 1.5"
grid mounting option is specified.
4.46"
(113mm)
47.75" x 47.75"
(1213mm x 1213mm)
Flange
Graphic Image Size Needed – 4' × 4' Fixture
Grid 1.0" (G10)Grid 1.5" (G15)
44.575" × 44.575"
44.075" × 44.075"
ORDERING INFORMATION
Series
Mounting Opt
CSMRI44
Mounting Options
G10 Grid (1")
G15 Grid (1.5")
102
Lamp Type
Voltage
L191
DV
Image
Lamp Type
L191 191W HB White LED (6500K)
Voltage
DV
120/230 Volts
Image Selection
Please see www.kenall.com for CleanScene
lightbox image selections and ordering numbers.
Selected image must be marked for C4 or D2
usage. Consult factory for alternate image selection approval.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Stratalume Connects™
Maucsl SERIES
solid front
Undercabinet Lighting
Lamps: T5, T5HO
PROJECT INFORMATION
Height
1.25"
Width
4.50"
Job Name
Length
1', 2', 3', 4', 5'
Fixture Type
Catalog Number 1 Wiring Module w/
Hospital Grade Outlet
2 Wiring Module w/
Rocker Switch
3 Power Cordset
4 Interconnect Cordset 1
Approved by
2
3
4
SPECIFICATIONS
Lens: U.V. stabilized, high-impact resistant,
extruded frost 100% DR acrylic. Smooth exterior,
linear prism interior. Snap-in toolless entry design.
connectors provided at ends of series-mount fixtures. See Options and Accessories for additional
electrical capabilities.
Housing: Extruded marine-grade aluminum.
Nominal thickness: 0.060". Standard antimicrobial
finish.
Electrical Accessories: Wiring modules
available with 15 amp hospital grade outlet or
master switch. Construction and installation
match fixtures. Cordsets: Custom-molded plugs,
SVT cord, snap-together design. Power cordsets connect to left side of fixture series; 120V
wall outlet powered, 6 amps max. Interconnect
cordsets electrically connect fixtures. Available in
white or black finish.
End Caps/Covers: U.V. stabilized, high-impact
resistant, injection-molded white or black opaque
polycarbonate. Black end caps/covers provided
when silver finish (SL) is ordered. Light leakpreventing interlocking design.
Electrical: Electronic ballast <10% THD.
Optional dimming ballast (DM7): Programmed
Start; <10% THD. All ballasts high power factor;
UL listed, Class P; Class A audible noise rating.
3500K lamps pre-installed at factory (4200K on
F8T5 and F13T5). Male and female grounded
DIMENSIONAL DATA
Gasket: Closed-cell extruded EPDM gasket
seals lens to end caps..
Sockets: Shock-resistant sockets with internal
locking collar to ensure positive lamp retention.
Installation: External mounting feet allow
installation without accessing internal compartments. Four-point mounting required for individual
fixtures and initial fixture in series-mount run.
Two-point mounting required for subsequent
series-mount fixtures. UL fitting for 3/8" flexible
conduit or NM wire supplied. Direct wire in rear
of fixture uses push-in connectors behind quickaccess cover. Direct wire into sides of fixture
uses included adapter plate. Maximum current of
series-runs 6 amps per circuit (see back table).
Listings/Certifications: UL and CUL listed
for Damp Locations. Cord-equipped models listed
as Portable Luminaires. NSF2 – Splash Non-Food
Zone. Lifetime Guarantee against defects in
workmanship and materials (lamps excluded) for
product life of original installation.
Length Dimension – MAUCSL SeriesMax. Current
MODELLAMP
X Voltage
(in) (mm) 120V 277V 347V
14
(1) F8T5
14.27 362
0.08 —— ——
23
(1) F13T5
23.27 591
0.12 —— ——
25
(1) F14T5
24.53 623
0.16 0.07 ——
25HO
(1) F24T5HO
24.53 623
0.19 0.10 ——
27
(2) F8T5
27.00 686
0.16 —— ——
36
(1)F8T5 +(1) F13T5 36.00 914
0.20 —— ——
37
(1) F21T5 36.34 923
0.23 0.16 ——
37HO
(1) F39T5HO
36.34 923
0.34 0.15 ——
45
(2) F13T5
45.00 1143 0.24 —— ——
48
(1) F28T5
48.16 1223 0.30 0.14 ——
48HO
(1)F54T5HO
48.16 1223 0.53 0.23 0.19
60
(1) F35T5
59.97 1523 0.34 0.15 ——
WML
——
6.00 152
WML/HGO
——
8.00 203
WML/SW
——
6.00 152
Cross Section / Details
4.50"
(114mm)
1.25"
(32mm)
Top Mounting View
X"
NOTE: Subtract 0.54" for each end cover removed to get overall length
in series mount applications. When ordering the power or interconnect cordset, allow at least 2" clearance on the side of the fixture. To
calculate maximum allowable fixtures in a series run, divide 6 amps
maximum current by the maximum current of each fixture.
(4) 0.188" Mounting Holes
ORDERING INFORMATION
Series
Installation Type
Finish
Length/Lamps
Ballast Type
Voltage
Options
Accessories
Maucsl
Installation Type
I
Individual Mount
S
Series Mount
Finish
MW
MB
SL
CCW
CCB
Matte White Antimicrobial
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
Housing with White Endcaps
Custom Color Antimicrobial
Housing with Black Endcaps
Length/Lamps
14* 14.25" one 8 Watt (F8T5)
23* 23.25" one 13 Watt (F13T5)
25
24.5" one 14 Watt (F14T5)
25HO 24.5" one 24 Watt (F24T5HO)
27* 27" two 8 Watt (F8T5)
36* 36" one 8 Watt (F8T5) &
one 13 Watt (F13T5)
37
36.35" one 21 Watt (F21T5)
37HO 36.35" one 39 Watt (F39T5HO)
45* 45" two 13 Watt (F13T5)
48
48.188" one 28 Watt (F28T5)
48HO 48.188" one 54 Watt (F54T5HO)
60
60" one 35 Watt (F35T5)
Ballast Type
RS
Rapid Start Electronic <10% THD
DM7t Low Voltage Electronic Dimming Ballast
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347l 347 Volts
Options
2C
Series Mount Two-Circuit Wiring
(n/a with EDB)
HGO* Hospital Grade Grounded Outlet15A, 125V (n/a w/one F8T5 lamp)
(Individual Mount only)
CS* 8’ Hard-wired Cordset
FS
Single Fuse & Holder
LD
Lamp Delete Option
SW* Rocker Switch
* 120 Volts only
Available with F14T5, F21T5, F28T5, F35T5,
and F54T5HO lamps
l
Available with F54T5HO lamp, RS ballast
only
t
Accessories (Series Mount only)**
WML
6" Wiring Module w/o Accessory
WML/HGO* 8" Wiring Module w/ Hospital Grade Outlet
WML/SW* 6" Wiring Module w/Rocker Switch
PCL2*
2’ Straight Power Cordset
PCL3*
3’ Straight Power Cordset
PCL4*
4’ Straight Power Cordset
PCL6*
6’ Straight Power Cordset
PCL10*
10’ Straight Power Cordset
ICL05*
6" Straight Interconnect Cordset
ICL1*
1’ Straight Interconnect Cordset
ICL2*
2’ Straight Interconnect Cordset
ICL3*
3’ Straight Interconnect Cordset
** When ordering Accessories, add color suffix:
–WHT white, –BLK black, –SLV silver,
–CCW/–CCB custom color (–SLV and –CCW/
–CCB for Wiring Modules only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
103
103
Stratalume Connects™
MAUCSD SERIES
PROJECT INFORMATION
solid front
Undercabinet Lighting
Lamps: T8, Biaxial
Height
1.70"
Width
5.66"
Length
1', 2', 3', 4', 5'
Job Name
Fixture Type
Catalog Number 1 Wiring Module w/
Hospital Grade Outlet
2 Wiring Module w/
Motion Sensor
3 Power Cordset
4 Interconnect Cordset 1
Approved by
2
3
4
SPECIFICATIONS
Lens: U.V. stabilized, high-impact resistant,
extruded frost 100% DR acrylic. Smooth exterior,
linear prism interior. Snap-in toolless entry
design.
Rapid Start ballast included with motion sensor
option. 3500K lamps pre-installed at factory. Male
and female grounded connectors provided at
ends of series-mount fixtures. See Options and
Accessories for additional electrical capabilities.
Housing: Extruded marine-grade aluminum.
Nominal thickness: 0.060". Standard antimicrobial
finish.
Electrical Accessories: Wiring modules
available with 15 amp hospital grade outlet or
master switch. Construction and installation
match fixtures. Cordsets: Custom-molded plugs,
SVT cord, snap-together design. Power cordsets
connect to left side of fixture series; 120V wall
outlet powered, 6 amps max. Interconnect
cordsets electrically connect fixtures. Available in
white or black finish.
End Caps/Covers: U.V. stabilized, high-impact
resistant, injection-molded white or black opaque
polycarbonate. Black end caps/covers provided
when silver finish (SL) is ordered. Light leakpreventing interlocking design.
Electrical: Electronic ballast <10% THD. Optional electronic ballast (RS): Rapid Start; <10%
THD; Suitable for use with occupancy sensors.
Optional dimming ballast (DM7): Programmed
Start; <10% THD. All ballasts high power factor;
UL listed, Class P; Class A audible noise rating.
Gasket: Closed-cell extruded EPDM gasket
seals lens to end caps..
Installation: External mounting feet allow
installation without accessing internal compartments. Four-point mounting required for individual fixtures and initial fixture in series-mount
run. Two-point mounting required for subsequent
series-mount fixtures. Direct wire in rear of
fixture uses push-in connectors behind quickaccess cover (7/8" KO). Direct wire into sides of
fixture uses included adapter plate. Maximum
current of series-runs 6 amps per circuit (see
back table).
Listings/Certifications: UL and CUL listed
for Damp Locations. Cord-equipped models listed
as Portable Luminaires. NSF2 – Splash Non-Food
Zone. Lifetime Guarantee against defects in
workmanship and materials (lamps excluded) for
product life of original installation.
Sockets: Shock-resistant sockets with internal
locking collar to ensure positive lamp retention.
DIMENSIONAL DATA
Length Dimension – MAUCSD SeriesMax. Current
MODELLAMP X Voltage
(in) (mm) 120V 277V 347V
14
(1) F18TT
14.00 356
0.37 —— ——
17
(1) F27TT
17.00 432
0.18 0.10 ——
26
(1) F17T8
26.12 663
0.20 0.08 ——
27
(1) F40TT
27.00 686
0.34 0.15 ——
38
(1) F25T8
38.12 968
0.26 0.11 0.09
50
(1) F32T8
50.12 1273 0.29 0.13 0.12
62
(1) F40T8 62.12 1578 0.37 0.16 ——
WMD
——
6.00 152
WMD/HGO
——
8.00 203
WMD/SW
——
6.00 152
WMD/MS
——
8.00 203
Cross Section / Details
5.66"
(144mm)
1.70"
(43mm)
Top Mounting View
X"
NOTE: Subtract 0.54" for each end cover removed to get overall length
in series mount applications. When ordering the power or interconnect cordset, allow at least 2" clearance on the side of the fixture. To
calculate maximum allowable fixtures in a series run, divide 6 amps
maximum current by the maximum current of each fixture.
(4) 0.188" Mounting Holes
ORDERING INFORMATION
Series
Installation Type
Finish
Length/Lamps
Ballast Type
Voltage
Options
Accessories
MAUCSD
Installation Type
I
Individual Mount
S
Series Mount
Finish
MW
MB
SL
CCW
CCB
Matte White Antimicrobial
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
Housing with White Endcaps
Custom Color Antimicrobial
Housing with Black Endcaps
Length/Lamps
14* 14" one 18 Watt Biax (F18TT)
17
17" one 27 Watt Biax (F27TT)
26
26.125" one 17 Watt (F17T8)
27
27" one 40 Watt Biax (F40TT)
38
38.125" one 25 Watt (F25T8)
50
50.125" one 32 Watt (F32T8)
62
62.125" one 40 Watt (F40T8)
104
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RSt Rapid Start Electronic <10% THD
(CFL,T8)
DM7t Low Voltage Electronic Dimming Ballast
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347l 347 Volts
Options
2C
Series Mount Two-Circuit Wiring
HGO* Hospital Grade Grounded Outlet
15A, 125V (n/a w/F18TT and F27TT lamps) (Individual Mount only)
CS* 8’ Hard-wired Cordset
FS
Single Fuse & Holder
LD
Lamp Delete Option
MSt Motion Sensor (120/277V only)
SW* Rocker Switch (n/a w/F27TT lamp)
Accessories (Series Mount only)**
WMD
6" Wiring Module w/o Accessory
WMD/HGO*8" Wiring Module w/ Hospital Grade Outlet
WMD/SW* 6" Wiring Module w/Rocker Switch
WMD/MS 8" Wiring Module w/Motion Sensor
PCD2*
2’ Straight Power Cordset
PCD3*
3’ Straight Power Cordset
PCD4*
4’ Straight Power Cordset
PCD6*
6’ Straight Power Cordset
PCD10* 10’ Straight Power Cordset
ICD05*
6" Straight Fixture Interconnect
Cordset
ICD1*
1’ Straight Interconnect Cordset
ICD2*
2’ Straight Interconnect Cordset
ICD3*
3’ Straight Interconnect Cordset
* 120 Volts only
Available with F17T8, F25T8, and F32T8
lamps
l
Available with F25T8 and F32T8 lamps,
IS ballast only
** When ordering Accessories, add color suffix:
–WHT white, –BLK black, –SLV silver,
–CCW/–CCB custom color (–SLV and –CCW/
–CCB for Wiring Modules only)
t
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Stratalume Connects™
Maucdl SERIES
lUMINOUS front
Undercabinet Lighting
Lamps: T5, T5HO
PROJECT INFORMATION
Height
1.25"
Width
4.50"
Job Name
Length
1', 2', 3', 4', 5'
Fixture Type
Catalog Number 1 Wiring Module w/
Hospital Grade Outlet
2 Wiring Module w/
Rocker Switch
3 Power Cordset
4 Interconnect Cordset 1
Approved by
2
3
4
SPECIFICATIONS
Lens: U.V. stabilized, high-impact resistant,
extruded frost 100% DR acrylic. Smooth exterior,
linear prism interior. Snap-in toolless entry design.
connectors provided at ends of series-mount fixtures. See Options and Accessories for additional
electrical capabilities.
Housing: Extruded marine-grade aluminum.
Nominal thickness: 0.060". Standard antimicrobial
finish.
Electrical Accessories: Wiring modules
available with 15 amp hospital grade outlet or
master switch. Construction and installation
match fixtures. Cordsets: Custom-molded plugs,
SVT cord, snap-together design. Power cordsets connect to left side of fixture series; 120V
wall outlet powered, 6 amps max. Interconnect
cordsets electrically connect fixtures. Available in
white or black finish.
End Caps/Covers: U.V. stabilized, high-impact
resistant, injection-molded white or black opaque
polycarbonate. Black end caps/covers provided
when silver finish (SL) is ordered. Light leakpreventing interlocking design.
Electrical: Electronic ballast <10% THD.
Optional dimming ballast (DM7): Programmed
Start; <10% THD. All ballasts high power factor;
UL listed, Class P; Class A audible noise rating.
3500K lamps pre-installed at factory (4200K on
F8T5 and F13T5). Male and female grounded
DIMENSIONAL DATA
Sockets: Shock-resistant sockets with internal
locking collar to ensure positive lamp retention.
Listings/Certifications: UL and CUL listed
for Damp Locations. Cord-equipped models listed
as Portable Luminaires. NSF2 – Splash Non-Food
Zone. Lifetime Guarantee against defects in
workmanship and materials (lamps excluded) for
product life of original installation.
Length Dimension – MAUCDL SeriesMax. Current
MODELLAMP X Voltage
(in) (mm) 120V 277V 347V
14
(1) F8T5
14.27
362
0.08 —— ——
23
(1) F13T5
23.27
591
0.12 —— ——
25
(1) F14T5
24.53
623
0.16 0.07 ——
25HO
(1) F24T5HO
24.53
623
0.19 0.10 ——
27
(1) F8T5
27.00
686
0.16 —— ——
36
(1) F8T5 + (1) F13T536.00
914
0.20 —— ——
37
(1) F21T5
36.34
923
0.23 0.16 ——
37HO
(1) F39T5HO 36.34
923
0.34 0.15 ——
45
(1) F13T5
45.00 1143 0.24 —— ——
48
(1) F28T5 48.16 1223 0.30 0.14 ——
48HO
(1) F54T5HO 48.16 1223 0.53 0.23 0.19
60
(1) F35T5
59.97 1523 0.34 0.15 ——
WML
——
6.00
152
WML/HGO
——
8.00
203
WML/SW
——
6.00
152
Cross Section / Details
4.50"
(114mm)
1.25"
(32mm)
Top Mounting View
Gasket: Closed-cell extruded EPDM gasket
seals lens to end caps..
Installation: External mounting feet allow
installation without accessing internal compartments. Four-point mounting required for individual
fixtures and initial fixture in series-mount run.
Two-point mounting required for subsequent
series-mount fixtures. UL fitting for 3/8" flexible
conduit or NM wire supplied. Direct wire in rear
of fixture uses push-in connectors behind quickaccess cover. Direct wire into sides of fixture
uses included adapter plate. Maximum current of
series-runs 6 amps per circuit (see back table).
X"
(4) 0.188" Mounting Holes
NOTE: Subtract 0.54" for each end cover removed to get overall length
in series mount applications. When ordering the power or interconnect cordset, allow at least 2" clearance on the side of the fixture. To
calculate maximum allowable fixtures in a series run, divide 6 amps
maximum current by the maximum current of each fixture.
ORDERING INFORMATION
Series
Installation Type
Finish
Length/Lamps
Ballast Type
Voltage
Options
Accessories
Maucdl
Installation Type
I
Individual Mount
S
Series Mount
Finish
MW
MB
SL
CCW
CCB
Matte White Antimicrobial
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
Housing with White Endcaps
Custom Color Antimicrobial
Housing with Black Endcaps
Length/Lamps
14* 14.25" one 8 Watt (F8T5)
23* 23.25" one 13 Watt (F13T5)
25
24.5" one 14 Watt (F14T5)
25HO 24.5" one 24 Watt (F24T5HO)
27* 27" two 8 Watt (F8T5)
36* 36" one 8 Watt (F8T5) &
one 13 Watt (F13T5)
37
36.35" one 21 Watt (F21T5)
37HO 36.35" one 39 Watt (F39T5HO)
45* 45" two 13 Watt (F13T5)
48
48.188" one 28 Watt (F28T5)
48HO 48.188" one 54 Watt (F54T5HO)
60
60" one 35 Watt (F35T5)
Ballast Type
RS
Rapid Start Electronic <10% THD
DM7t Low Voltage Electronic Dimming Ballast
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347l 347 Volts
Options
2C
Series Mount Two-Circuit Wiring
(n/a with EDB)
HGO* Hospital Grade Grounded Outlet15A, 125V (n/a w/one F8T5 lamp)
(Individual Mount only)
CS* 8’ Hard-wired Cordset
FS
Single Fuse & Holder
LD
Lamp Delete Option
SW* Rocker Switch
* 120 Volts only
Available with F14T5, F21T5, F28T5, F35T5,
and F54T5HO lamps
l
Available with F54T5HO lamp, RS ballast
only
t
Accessories (Series Mount only)**
WML
6" Wiring Module w/o Accessory
WML/HGO* 8" Wiring Module w/ Hospital Grade Outlet
WML/SW* 6" Wiring Module w/Rocker Switch
PCL2*
2’ Straight Power Cordset
PCL3*
3’ Straight Power Cordset
PCL4*
4’ Straight Power Cordset
PCL6*
6’ Straight Power Cordset
PCL10*
10’ Straight Power Cordset
ICL05*
6" Straight Interconnect Cordset
ICL1*
1’ Straight Interconnect Cordset
ICL2*
2’ Straight Interconnect Cordset
ICL3*
3’ Straight Interconnect Cordset
** When ordering Accessories, add color suffix:
–WHT white, –BLK black, –SLV silver,
–CCW/–CCB custom color (–SLV and –CCW/
–CCB for Wiring Modules only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
105
105
Stratalume Connects™
Maucdd SERIES
Luminous front
Undercabinet Lighting
Lamps: T8, Biaxial
PROJECT INFORMATION
Height
1.70"
Width
5.66"
Job Name
Length
1', 2', 3', 4', 5'
Fixture Type
Catalog Number 1 Wiring Module w/
Hospital Grade Outlet
2 Wiring Module w/
Motion Sensor
3 Power Cordset
4 Interconnect Cordset 1
Approved by
2
3
4
SPECIFICATIONS
Lens: U.V. stabilized, high-impact resistant,
extruded frost 100% DR acrylic. Smooth exterior,
linear prism interior. Snap-in toolless entry
design.
Rapid Start ballast included with motion sensor
option. 3500K lamps pre-installed at factory. Male
and female grounded connectors provided at
ends of series-mount fixtures. See Options and
Accessories for additional electrical capabilities.
Housing: Extruded marine-grade aluminum.
Nominal thickness: 0.060". Standard antimicrobial
finish.
Electrical Accessories: Wiring modules
available with 15 amp hospital grade outlet or
master switch. Construction and installation
match fixtures. Cordsets: Custom-molded plugs,
SVT cord, snap-together design. Power cordsets
connect to left side of fixture series; 120V wall
outlet powered, 6 amps max. Interconnect
cordsets electrically connect fixtures. Available in
white or black finish.
End Caps/Covers: U.V. stabilized, high-impact
resistant, injection-molded white or black opaque
polycarbonate. Black end caps/covers provided
when silver finish (SL) is ordered. Light leakpreventing interlocking design.
Electrical: Electronic ballast <10% THD. Optional electronic ballast (RS): Rapid Start; <10%
THD; Suitable for use with occupancy sensors.
Optional dimming ballast (DM7): Programmed
Start; <10% THD. All ballasts high power factor;
UL listed, Class P; Class A audible noise rating.
Gasket: Closed-cell extruded EPDM gasket
seals lens to end caps..
Listings/Certifications: UL and CUL listed
for Damp Locations. Cord-equipped models listed
as Portable Luminaires. NSF2 – Splash Non-Food
Zone. Lifetime Guarantee against defects in
workmanship and materials (lamps excluded) for
product life of original installation.
Sockets: Shock-resistant sockets with internal
locking collar to ensure positive lamp retention.
DIMENSIONAL DATA
Length Dimension – MAUCDD SeriesMax. Current
MODELLAMP X Voltage
(in) (mm) 120V 277V 347V
14
(1) F18TT
14.00 356
0.37 —— ——
17
(1) F27TT
17.00 432
0.18 0.10 ——
26
(1) F17T8
26.12 663
0.20 0.08 ——
27
(1) F40TT
27.00 686
0.34 0.15 ——
38
(1) F25T8
38.12 968
0.26 0.11 0.09
50
(1) F32T8
50.12 1273 0.29 0.13 0.12
62
(1) F40T8 62.12 1578 0.37 0.16 ——
WMD
——
6.00 152
WMD/HGO
——
8.00 203
WMD/SW
——
6.00 152
WMD/MS
——
8.00 203
Cross Section / Details
5.66"
(144mm)
1.70"
(43mm)
Top Mounting View
Installation: External mounting feet allow
installation without accessing internal compartments. Four-point mounting required for individual fixtures and initial fixture in series-mount
run. Two-point mounting required for
subsequent series-mount fixtures. Direct wire in
rear of fixture uses push-in connectors behind
quick-access cover (7/8" KO). Direct wire into
sides of fixture uses included adapter plate. Maximum current of series-runs 6 amps per circuit
(see back table).
X"
NOTE: Subtract 0.54" for each end cover removed to get overall length
in series mount applications. When ordering the power or interconnect cordset, allow at least 2" clearance on the side of the fixture. To
calculate maximum allowable fixtures in a series run, divide 6 amps
maximum current by the maximum current of each fixture.
(4) 0.188" Mounting Holes
ORDERING INFORMATION
Series
Installation Type
Finish
Length/Lamps
Ballast Type
Voltage
Options
Accessories
MAUCDD
Installation Type
I
Individual Mount
S
Series Mount
Finish
MW
MB
SL
CCW
CCB
Matte White Antimicrobial
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
Housing with White Endcaps
Custom Color Antimicrobial
Housing with Black Endcaps
Length/Lamps
14* 14" one 18 Watt Biax (F18TT)
17
17" one 27 Watt Biax (F27TT)
26
26.125" one 17 Watt (F17T8)
27
27" one 40 Watt Biax (F40TT)
38
38.125" one 25 Watt (F25T8)
50
50.125" one 32 Watt (F32T8)
62
62.125" one 40 Watt (F40T8)
106
Ballast Type
IS
Instant Start Electronic <10% THD (T8)
RSt Rapid Start Electronic <10% THD
(CFL,T8)
DM7t Low Voltage Electronic Dimming Ballast
SB
Specified Ballast
Voltage
120 120 Volts
277 277 Volts
347l 347 Volts
Options
2C
Series Mount Two-Circuit Wiring
HGO* Hospital Grade Grounded Outlet15A, 125V (n/a w/F18TT and F27TT
lamps) (Individual Mount only)
CS* 8’ Hard-wired Cordset
FS
Single Fuse & Holder
LD
Lamp Delete Option
MSt Motion Sensor (120/277V only)
SW* Rocker Switch (n/a w/F27TT lamp)
Accessories (Series Mount only)**
WMD
6" Wiring Module w/o Accessory
WMD/HGO*8" Wiring Module w/ Hospital Grade Outlet
WMD/SW* 6" Wiring Module w/Rocker Switch
WMD/MS 8" Wiring Module w/Motion Sensor
PCD2*
2’ Straight Power Cordset
PCD3*
3’ Straight Power Cordset
PCD4*
4’ Straight Power Cordset
PCD6*
6’ Straight Power Cordset
PCD10* 10’ Straight Power Cordset
ICD05*
6" Straight Interconnect Cordset
ICD1*
1’ Straight Interconnect Cordset
ICD2*
2’ Straight Interconnect Cordset
ICD3*
3’ Straight Interconnect Cordset
* 120 Volts only
Available with F17T8, F25T8, and F32T8
lamps
l
Available with F25T8 and F32T8 lamps,
IS ballast only
** When ordering Accessories, add color
suffix: –WHT white, –BLK black, –SLV silver,
–CCW/–CCB custom color (–SLV and
–CCW/–CCB for Wiring Modules only)
t
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
Stratalume Connects™
Maucled SERIES
solid front
Undercabinet Lighting
Lamps: LED
PROJECT INFORMATION
Height
1.25"
Width
4.50"
Job Name
Length
1', 1.5', 2', 2.5', 3', 3.5', 4'
Fixture Type
Catalog Number 1 Wiring Module w/
Hospital Grade Outlet
2 Wiring Module w/
Rocker Switch
3 Power Cordset
4 Interconnect Cordset 1
Approved by
2
3
4
SPECIFICATIONS
Electrical Accessories: Wiring modules
available with 15 amp hospital grade outlet or
master switch. Construction and installation
match fixtures. Cordsets: Custom-molded plugs,
SVT cord, snap-together design. Power cordsets connect to left side of fixture series; 120V
wall outlet powered, 6 amps max. Interconnect
cordsets electrically connect fixtures. Available in
white or black finish.
Lens: U.V. stabilized, high-impact resistant,
extruded frost 100% DR acrylic. Smooth exterior,
linear prism interior. Snap-in toolless entry design.
Housing: Extruded marine-grade aluminum.
Nominal thickness: 0.060". Standard antimicrobial
finish.
End Caps/Covers: U.V. stabilized, high-impact
resistant, injection-molded white or black opaque
polycarbonate. Black end caps/covers provided
when silver finish (SL) is ordered. Light leakpreventing interlocking design.
Gasket: Closed-cell extruded EPDM gasket
seals lens to end caps.
Installation: External mounting feet allow
installation without accessing internal compartments. Four-point mounting required for individual
fixtures and initial fixture in series-mount run.
Two-point mounting required for subsequent
series-mount fixtures. UL fitting for 3/8" flexible
Electrical: High brightness, 4100K white
LEDs. High power factor driver; <20% THD. Male
and female grounded connectors provided at
ends of series-mount fixtures. See Options and
Accessories for additional electrical capabilities.
DIMENSIONAL DATA
conduit or NM wire supplied. Direct wire in rear
of fixture uses push-in connectors behind quickaccess cover. Direct wire into sides of fixture
uses included adapter plate. Maximum current of
series-runs 6 amps per circuit (see back table).
Listings/Certifications: UL and CUL listed
for Dry Locations. Cord-equipped models listed
as Portable Luminaires. NSF2 – Splash Non-Food
Zone. LED lamps warranted for 50,000-hour life
based on 70% original lumen output. Lifetime
Guarantee against defects in workmanship and
materials for product life of original installation.
Length Dimension – MAUCLED SeriesMax. Current
MODELLAMP X Voltage
(in) (mm)
120V
12
LED12
13.00
330
——
18
LED18
18.50
470
0.129
24
LED24
24.00
610
0.194
30
LED30
29.50
749
0.259
36
LED36
35.00
889
0.323
42
LED42
40.50 1029
0.453
48
LED48 46.00 1168
0.517
WML
——
6.00
152
WML/HGO
——
8.00
203
WML/SW
——
6.00
152
Cross Section / Details
4.50"
(114mm)
1.25"
(32mm)
Top Mounting View
X"
NOTE: Subtract 0.54" for each end cover removed to get overall
length in series mount applications. When ordering the power or
interconnect cordset, allow at least 2" clearance on the side of the
fixture. To calculate maximum allowable fixtures in a series run, divide
6 amps maximum current by the maximum current of each fixture.
(4) 0.188" Mounting Holes
ORDERING INFORMATION
Series
Installation Type
Finish
Length/LED Power Voltage
Maucled
Installation Type
I
Individual Mount
S
Series Mount
Finish
MW
M
SL
CCW
CCB
Matte White Antimicrobial
Matte Black Antimicrobial
Silver Antimicrobial
Custom Color Antimicrobial
Housing with White Endcaps
Custom Color Antimicrobial
Housing with Black Endcaps
Options
Accessories
120
Length/LED Power
12
13" – 12 Watt
18
18.5" – 18 Watt
24
24" – 24 Watt
30
29.5" – 30 Watt
36
35" – 36 Watt
42
40.5" – 42 Watt
48
46" – 48 Watt
Voltage
120 120 Volts
Options
2C
Series Mount Two-Circuit Wiring
HGO Hospital Grade Grounded Outlet15A, 125V (n/a with 12 Watt fixture)
(Individual Mount only)
CS
8’ Hard-wired Cordset
FS
Single Fuse & Holder
SW Rocker Switch
Accessories (Series Mount only)**
WML
6" Wiring Module w/o Accessory
WML/HGO* 8" Wiring Module w/ Hospital Grade Outlet
WML/SW* 6" Wiring Module w/Rocker Switch
PCL2
2’ Straight Power Cordset
PCL3
3’ Straight Power Cordset
PCL4
4’ Straight Power Cordset
PCL6
6’ Straight Power Cordset
PCL10
10’ Straight Power Cordset
ICL05
6" Straight Interconnect Cordset
ICL1
1’ Straight Interconnect Cordset
ICL2
2’ Straight Interconnect Cordset
ICL3
3’ Straight Interconnect Cordset
** When ordering Accessories, add color suffix:
–WHT white, –BLK black, –SLV silver,
–CCW/–CCB custom color (–SLV and –CCW/
–CCB for Wiring Modules only)
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
107
107
IP65
HoSEDOWN RATINGS & THEIR RELATION TO IP RATINGS
Limitations of Wet & Hosedown
Ratings – UL Standards
UL standards for “wet” type ratings
only offer a wet location rating, which
simulates an outdoor rain condition. UL
standards for a type 4 or NEMA 4 “hosedown” rating uses a 1 inch diameter
nozzle on a fire hose delivering 65 gallons
of water per minute. Various conditions
exist where a fixture requires a rating
better than a wet location label but not
NEMA 4. These conditions typically exist
in washdown applications where hose
directed water or cleaning agents
will be directed at the fixture.
Benefits of Ingress Protection
Ratings – IEC standards
The IP water rating of "5," described in
IEC Standard 529, provides an intermediate step between the rain rating and
the NEMA 4 rating. It also provides an
internationally accepted standard which
can be used to evaluate fixtures or any
other electrical equipment, and the test
can be performed by an independent
third party testing agency for verification.
Underwriters Laboratories in Northbrook,
Illinois investigates products and tests to
the IEC standard.
Dust-tight Protection
MedMaster™ Ratings
An additional test criterion that can be
applied to fixtures is the ability to exclude
solid matter. The IP solid rating of "6"
(IP6_) means the fixture will be dust
tight. The specified test requires that
the fixture be placed in a circulating talc
atmosphere for 3 hours. The particle
size of the talc is a range of one to 75
microns and the fixture is placed under
negative pressure in an attempt to draw
the talc into the fixture. No talc shall be
found inside the fixture after this test.
Kenall’s MedMaster line of hosedown
rated products are approved by UL and
CUL for IP ratings according to IEC Standard 529.
The Importance of Recognized
Standards & Independent
Testing
What are IEC Standards?
IEC Standards are international standards
that many European countries adopt as
their national standard. North America
has traditionally adopted UL standards
as the source for standards. U.S. product
manufacturers designed their products to
IEC standards initially for sale overseas
but are finding them increasingly useful
here in North America.
Other lighting manufacturers that claim a
hosedown rating other than NEMA or IP
are not testing to recognized standards
and cannot have the tests confirmed or
audited by an independent outside testing agency.
Beware of statements such as "Tested
to 75psi at 1 inch." No reference is made
to the volume of water that is leaving
the nozzle and impacting the product. In
fact, high nozzle pressures typically have
low water volumes because the nozzle
is restricting the flow of water causing
the pressure in the hose to increase,
minimizing the amount of water leaving
the nozzle.
Regardless of the hose pressure, any
water volume less than 3.3 gal/minute is
less severe than the IP_5 test. The most
relevant characteristics are the diameter
of the nozzle and the flow rate of the
water. The following chart shows the test
characteristics for various Standards.
IP STANDARDS CHARACTERISTICS
108
Rating Standard Flow Rate Distance Duration
IP_5 IEC 529/598 0.2 inches Nozzle Dia 3.3 gal/min 8-10 ft 15 min
NEMA4 NEMA 250 1.0 inches 65 gal/min 10-12 ft 5 min
Marine UL 595 1.0 inches 115 gal/min 10 ft 5 min
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
IP RATINGS: NUMERICAL ASSIGNMENTS & EXPLANATIONS
IP65
IP65
Degrees of protection indicated by the first characteristic numeral
Numeral Short Description Brief details of objects which will be “excluded”
from the enclosure
No special protection
0
Non-protected 1 Protected against solid objects greater than 50 mm
A large surface of the body, such as a hand
(but no protection against deliberate access).
Solid objects exceeding 50 mm in diameter.
2
Protected against solid objects greater than 12 mm
Fingers or similar objects not exceeding 80 mm in
Solid objects exceeding 12 mm in diameter.
3 Protected against solid objects greater than 2.5 mm
Tools, wires, etc., of diameter or thickness greater than
Solid objects exceeding 2.5 mm in diameter.
4 Protected against solid objects greater than 1.0 mm Wires or strips of thickness greater than 1.0 mm.
Solid objects exceeding 1.0 mm in diameter.
5 Dust-protected Ingress of dust is not totally prevented but dust does
not enter in sufficient quantity to interfere with
satisfactory operation of the equipment.
No ingress of dust
6
Dust-tight Degrees of protection indicated by the second characteristic numeral
Numeral
Short Description Brief details of objects which will be “excluded” from the enclosure
No special protection
0
Non-protected 1 Protected against dripping water Dripping water (vertically falling drops) shall have no
harmful effect.
2 Protected against dripping water when tilted up to 15°
Vertically dripping water shall have no harmful effect
when tilted up to 15° when the enclosure is tilted at any angle up to 15° from its normal position.
3 Protected against spraying water Water falling as a spray at an angle up to 60° from
the vertical shall have no harmful effect.
4 Protected against splashing water Water splashed against the enclosure from any
direction shall have no harmful effect.
5 Protected against water jets Water projected by a nozzle against the enclosure from
any direction shall have no harmful effects.
6 Protected against heavy seas Water from heavy seas or water projected in powerful
jets shall not enter the enclosure in harmful quantities.
7 Protected against the effects of immersion Ingress of water in a harmful quantity shall not be
possible when the enclosure is immersed in water
under defined conditions of pressure and time.
8 Protected against submersion The equipment is suitable for continuous submersion in
water under conditions which shall be specified by the manufacturer.
NOTE – Normally, this will mean that the equipment is hermetically sealed. However with certain types of equipment it can mean that water can enter but only in such a manner that it produces no harmful effects.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
109
109
NSF-49
PRESSURIZED LEAK TESTING & CLEANROOM COMPATIBILITY STUDIES
Lighting Fixtures & Pressurized
Environments
NSF-49-2004a “Class II (Laminar Flow)
Biosafety Cabinetry”.
Large numbers of R&D, high-tech manufacturing and medical facilities contain
areas in which environmental isolation
and the prevention of cross-contamination are critical. Applications such as
cleanrooms and surgical suites must
be kept free of external contaminants
while others, such as infectious disease
isolation areas and R&D bio-containment
spaces must prevent contaminants from
escaping.
Testing for stringent compliance at the
same level and under the procedures
prescribed in NSF-49-2004a determines
the fixture’s ability to restrict the passage
or penetration of contaminants in one
or more directions when subjected to
the prescribed pressure level. In short, it
measures a fixture’s resistance to leakage in pressurized environments.
The need for environmental isolation in
these areas is so critical that air pressure
is used as a buffer against contamination.
Positive pressure is employed where the
introduction of foreign matter causes
contamination, while negative pressure
creates a barrier to contaminant egress
where containment is the critical issue.
When anything – including a lighting
fixture – penetrates the ceiling, it creates
the potential for contaminant leakage.
Consequently, luminaires must be free
of openings through which contaminants
can pass or that could result in a reduction of pressure. Simply put, a key performance requirement for lighting fixtures in
pressurized environments is the ability to
prevent leakage.
Leakage Prevention Standard
Unlike the European Community, there
is no mandatory U.S. standard specific
to luminaire leakage in pressurized applications. There is, however, a widely
accepted leakage standard developed
by the National Sanitation Foundation
(NSF) in conjunction with the American
National Standards Institute (ANSI) that
can be effectively applied to light fixtures:
The test is performed using a special
airtight chamber containing a pressure
plenum fabricated to simulate the type of
ceiling surface to which the fixture will be
mounted. The plenum is pressurized to
the prescribed level and sealed; pressure
readings are then recorded on a water
gauge at five minute intervals. In order
to comply with NSF-49- 2004a levels,
the fixture must be able to maintain two
inches of pressure, plus or minus 10%,
for 30 minutes.
Positive Pressure Applications
Cleanrooms
As spaces defined by their level of
cleanliness, cleanrooms require lighting
fixtures capable of supporting the highest
levels of environmental integrity. Only by
selecting a fixture that has been tested
according to the methods outlined above
can the specifier be certain it is free of
gaps or holes through which contaminants can enter the space and have the
design features and mechanical integrity
– both within the fixture itself and at its
points of contact with the ceiling – to
maintain the target pressure level.
In addition, a fixture’s performance relative to cleanroom class requirements can
be easily determined through a second
test performed in conjunction with
the NSF-49-2004a emulated test. This
procedure, CRS-CCCS-GR2229, or the
Cleanliness Class Compatibility Study,
measures the fixture’s ability to seal out,
and not produce, airborne particles as
small as 0.1 micrometer.
While specifiers have traditionally used
Federal Standard 209E (Airborne Particulate Cleanliness Classes in Clean Rooms
and Clean Zones) to define cleanroom
classifications, the International Standards Organization (ISO) has now developed a new cleanroom rating system.
The chart on the left below provides a
comparison of ISO and Federal Standard
209E ratings; the chart to its right identifies the number of particles per cubic
meter, by micrometer size, for each ISO
cleanroom classification.
It’s important to note that although a
manufacturer may claim a fixture has
been tested within a certain class of
cleanroom, this neither means the fixture
has been tested according to accepted
procedures nor that it meets the performance requirements of the intended application without, at a minimum, application of the two tests referenced above.
continued next page
ISO 14644-1FED STD 209E
CLASS Number of Particles per Cubic Meter by Micrometer Size
ISO Class English Metric
0.1um 0.2um 1
ISO 1 10 2
2
ISO 2 100 24 0.3um 0.5um 10 4
3 1
M1.5
ISO 3 1,000 237 102 35 8
4 10 M2.5
ISO 4 10,000 2,370 1,020 352 83
5 100 M3.5
ISO 5 100,000 23,700 10,200 3,520 832 6 1,000 M4.5
7 10,000 M4.5
8 100,000 M5.5
9
110
1um 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
5um
29
NSF-49
PRESSURIZED LEAK TESTING & CLEANROOM COMPATIBILITY STUDIES
Hospitals
Hospitals contain a variety of areas, including surgical suites, patient rooms and
ICUs, that are similar to cleanrooms in
that they use positive pressure as a barrier against contaminant ingress. Fixtures
that comply with prescribed pressure
testing are able to meet the leakage
prevention requirements for these applications – for both contaminant ingress
and the maintenance of target pressure
levels – with a wide safety margin.
Negative Pressure Applications
Major breakthroughs in the biological and
microbiological sciences have created
new processes and requirements for
bio-containment in both healthcare and
scientific research facilities. Responding
to growing needs for increasingly more
effective containment techniques, biocontainment cabinet manufacturers have
rapidly advanced in recent years, with a
number of technologies and techniques
now being applied to other equipment as
well as to larger and more complex areas
and environments.
Because these cabinets employ negatively pressurized interiors to provide the
most effective bio-containment possible,
they must be free of any holes, gaps, or
other openings that could allow leakage
compromising the effectiveness of the
cabinet’s negative pressure-based contamination barrier. From this perspective,
bio-containment cabinets have leakagebased performance requirements equivalent to those of lighting fixtures used in
larger pressurized environments.
In essence, the requirements of lighting fixtures are the same whether the
environment is negatively or positively
pressurized, meaning that a fixture meeting the leakage prevention levels required
in the NSF-49-2004a standard will be
equally effective in either scenario.
Research Facilities
Several varieties of biological and chemical research labs require negative pressure barriers in order to contain dangerous organisms and chemicals, making
them highly appropriate applications for
fixtures conforming to the leakage prevention levels specified in NSF-49-2004a.
Healthcare Facilities
In hospitals and other healthcare facilities
containing areas where patients infected
with highly contagious or communicable
diseases are isolated for treatment, as
well as those for patients under observation and being tested for infections from
dangerous organisms, are insulated from
the outside world by negative pressure
barriers and therefore require fixtures
conforming to the referenced levels of
performance in NSF-49-2004a.
Independent Testing
Testing a fixture for compliance with
the leakage performance standards in
NSF-49- 2004a should only be performed
by an independent testing lab with the
certification, knowledge, experience and
highly specialized equipment required to
perform the test properly and accurately.
MedMaster™
Performance results
Independent laboratory tests have verified that Kenall MedMaster fixtures comply with the performance levels specified
in NFS-49-2004a and therefore provide
an extra margin of protection against
leakage for all intended applications.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
111
111
NSF
NATIONAL SANITATION FOUNDATION LISTINGS
Fixtures for use in Food
Processing, Handling &
Preparation
Kenall lighting fixtures for use in food processing, handling and preparation areas
have been investigated and listed by the
National Sanitation Foundation (NSF) as
conforming to the requirements in their
criteria C2.
The purpose of criteria C2 is to insure
that equipment located in a food storage, handling, or preparation area will
not compromise the sanitation requirements for those areas. Equipment listed
to criteria C2 has been evaluated as to
its corrosion resistance, cleanability and
exposed material.
Splash Zones (SN)
Food Zones (FN)
Kenall has two levels of fixture construction depending on the area where the
fixtures are being installed.
The higher level of construction is our
FN type construction for Food Zone/NonFood Contact. Fixtures in this category
are physically located in food preparation and handling areas but do not come
in contact with the food under normal
conditions. All exposed sheet metal will
be painted CRS, painted aluminum, or anodized aluminum. Paint must meet U.S.
Code of Federal Regulations, Title 21 to
be used in this application. Fasteners will
be stainless steel and removable without
the use of a tool (thumbscrew type) and
the outer exposed lens must be an FDA
approved Food Grade polycarbonate
material.
Our SN type construction is listed for use
in Splash Zones and Non Food Zones.
All exposed sheet metal will be painted
CRS, painted aluminum, or anodized
aluminum. Fasteners will be stainless
steel, and lenses can be acrylic, polycarbonate or tempered glass, all with prisms
on inside.
Specifically, exposed materials shall
withstand normal wear, the corrosive
action of foods, beverages, and cleaning
compounds, and the material itself shall
not impart an odor, color, taste, or toxic
material to any food that would come in
contact with it.
Kenall cannot recommend which level of
construction is suitable for your specific
application as the final decision will rest
with the local inspector.
Within this category, NSF defines the
surfaces of equipment as Food Contact
or Non-Food Contact surfaces. Food
Contact surfaces are further divided into
areas as Food Zone, Splash Zone, and
Non-Food Zone, with Food Zone requirements being the most stringent and NonFood Zone being the least stringent.
A subcategory of Food Zone equipment
is Non-Contact, i.e. equipment in the
Food Zone but not normally in contact
with the food.
112
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
EMI
ELECTROMAGNETIC INTERFERENCE (EMI) TESTING & MILITARY STANDARD 461E
Where is EMI a Concern?
Military Standard 461E
Electromagnetic Interference (EMI) has
long been a critical concern in scientific
and healthcare facilities where it can
cause the malfunction of life support and
monitoring systems, surgical devices,
and other electrically sensitive medical and scientific equipment. In recent
years, concern over EMI has become
widespread due to its potential impact
on communications, security systems,
manufacturing equipment, and a variety
of sensitive electronic devices.
The most comprehensive, widely recognized and acknowledged domestic EMI
standard is Military Standard (MIL STD)
461E, a mandatory standard for military
hospitals and other EMI-sensitive military
facilities and a voluntary standard for public and private facilities applications. MIL
STD testing measurements cover both
radiated and conducted emissions in addition to maximum allowable amounts of
emitted energy based on both frequency
range and field strength.
Limitations of Required EMI
Standards
Unlike the European Community, the
United States has no comprehensive
standard for lighting-based EMI. Because high-frequency electronic ballasts
operate within radio, television and other
established communications bandwidths,
the Federal Communications Commission (FCC) issues standards for Electromagnetic Compatibility (EMC) between
certain devices as well as maximum radiated electromagnetic emissions levels
for some equipment, including electronic
ballasts.
FCC listings do not, however, provide
a standard for fluorescent lamps – also
radiators of EMI – or for complete luminaires. Further, the FCC does not issue
standards for conducted emissions.
The Food & Drug Administration (FDA)
issues EMC standards for certain medical devices operating outside the FCC’s
jurisdiction, but these standards typically
do not apply to light fixtures.
The MIL STD 461E testing procedures
and requirements appropriate to light fixtures are found under Navy and Air Force
Limits for Electronic Devices, with the
specific testing information for conducted
emissions outlined in CE 102-1 and for
radiated emissions in RE 102-4. While
both are designed to emulate worst case
operating conditions, both the test procedures and the standards themselves are
logical and reasonable.
Because MIL STD 461E standards are
harder to meet than either the FCC or European Community standards, luminaires
meeting them pose the lowest possible
likelihood of causing EMI-related problems.
The Importance of
Appropriate Standards &
Government Certified Labs
There are some particularly important
things to consider when evaluating or
specifying fixtures for EMI sensitive applications.
First, in order to make sure the tests
have been performed correctly and with
procedural exactness, verify that the
testing laboratory is accredited by either
the National Institute of Standards and
Technology (NIST) or the U.S. Dept. of
Commerce (DOC).
Second, check to see that electromagnetic emissions have been measured from
an application distance of one meter, as
some labs incorrectly take these measurements from as far as 10 meters from
the source.
Third, do not accept any manufacturer’s
assurance that because the luminaire’s
ballast carries an FCC listing, it meets
safety requirements, since the ballast is
only one potential source of EMI.
MedMaster™ Fixtures & EMI
Kenall MedMaster fixtures have been
tested and proven to be in compliance
with MIL STD 461E by an independent
laboratory (DLS Electronic Systems, Inc.)
accredited by both NIST and the U.S.
DOC. Copies of test reports are available
from Kenall.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
© Copyright 2009 Kenall Manufacturing Co. Inc. All rights reserved.
113
113
1020 Lakeside Drive
Gurnee, Illinois 60031
847-360-8200 FAX 847-360-1781
www.kenall.com
©2009 Kenall