1 919 s QBM4000-..., QBM4100-1U Differential pressure sensor QBM4100-1D QBM4000... QBM4100... For air and non-aggressive gases, with calibration certificate. • • • • • • Calibration certificate from the factory High degree of measuring accuracy Pressure-linear characteristic curve Operating voltage AC 24 V / DC 13.5...33 V or DC 11….33 V Output signal DC 0...10 V or 4…20 mA Simple and fast mounting thanks to integrated fixing angle bar in the housing Calibrated and temperature-compensated measuring signal Excellent long-term response Supplied with connection set Very short reaction time Display* indicates the present differential pressure • • • • • * Depending on type Use The differential pressure sensor acquires differential, over and under pressure of air and nonaggressive gases if a high degree of measuring accuracy and quality is required as well as a requirement for a calibration certificate. Fields of application: • • • • • CE1N1919en01 2014-07-30 Measuring slightest differential pressures in ventilation and air conditioning ducts Check air flows Monitor filters and control fans Pressure supervision in labs, production, storage and clean rooms For acquiring variable air flow in VAV plants on the supply and extract air side Building Technologies Type summary Type (ASN) Product number (SSN) Measuring range QBM4000-1 QBM4000-3 QBM4000-10 QBM4000-25 QBM4100-1U S55720-S247 S55720-S248 S55720-S249 S55720-S250 S55720-S251 0 ... 100 Pa 0 ... 300 Pa 0 ...1000 Pa 0 ...2500 Pa – 50 ... + 50 Pa DC 0 ... 10 V DC 0 ... 10 V DC 0 ... 10 V DC 0 ... 10 V 4 ... 20 mA No No No No No S55720-S252 0 ... 100 Pa 4 ... 20 mA Yes QBM4100-1D 1 1 Output signal LCD indication Type with digital display. Conversion 100 Pa = 1 hPa = 1 mbar Ordering and delivery When ordering a differential pressure sensor, please specify the quantity, type, and product name. Example Type (ASN) Product number (SSN) Product designation QBM4000-1 S55720-S247 Differential pressure sensor with calibration certificate. A round plug connector (Lumberg RKC 30/11) and a 2-meter PVC tube is included with the differential pressure sensor. Additional accessories may be ordered separately. Accessories Additional sets of air duct probes are available depending on measuring requirements. Various mounting brackets are also available depending on installation location. Type Name Data sheet AQB2000 Mounting bracket, for mounting sensors in isolated air ducts. N1590 AQB21.2 Top hat rail adapters (5 pieces) for DIN top hat rails, HT 35-7.5 N1590 FK-PZ1 Air duct probe, short, stainless steel, with elastic lead-through for simple, quick, and airtight mounting. N1589 FK-PZ2 Air duct probe, long, aluminum, with orifice plates for precise measuring requirements. N1589 Mode of operation The sensor acquires the differential pressure using a silicon rubber membrane and ceramic bar. The sensor generates as per the deflection, a linear and temperaturecompensated output signal DC 0...10 V or 4...20 mA. 2/6 Siemens Building Technologies Differential pressure sensor QBM4000…/ QBM4100… CE1N1919en01 2014-07-30 Design The differential pressure sensors consist of: • Sensor housing with fixing angle bar, 3-pin plug and hinged lid with sealed safety screw • Pressure chamber with membrane and ceramic lever • Circuit board • LCD display for the digital display of the sensor signal in Pa (for QBM41…D only) 1919Z 01 Display, setting, and connection elements 1 Key 2 3 4 1 3-pin plug 2 Display window (on QBM4100-1D only) for the digital display of the sensor signal 3 Connection nipples (see "Mounting notes") 4 Sealed safety screw for hinged cover Mounting and installation notes The differential pressure sensor is suited for direct mounting on air ducts, walls, ceilings, or in control panels. The sensor must be installed vertically. The supplied 2 meter plastic tubing can be modified to the duct connection on the plant. To achieve the housing protective class indicated under "Technical data", the differential pressure sensors must be mounted with the pressure nipple facing down. In addition, they should be higher than the air duct probes. Caution Note If the pressure connection nipples point upward or are at a lower level than the air duct probes, condensation can collect inside the sensor, causing damage to the device. The pressure tubing for the sensor nipples are connected as following to the differential pressure sensors: On the air duct side On the pressure sensor side Tubing with higher pressure side (lower vacuum) Connect to pressure nipple "P1" or "+". Tubing with lower pressure side (higher vacuum) Connect to pressure nipple "P2" or "−". The sensor is supplied with mounting instructions. 3/6 Siemens Building Technologies Differential pressure sensor QBM4000…/ QBM4100… CE1N1919en01 2014-07-30 Refer to the Manual sensor installation from the BT download center for additional information. Caution • Power supply by SELV or class 2 power supply with limited output of 15 W or less. (UL requirement) • Use only copper wiring Commissioning notes Caution Sensor calibration The values indicated under "Technical data" apply only to vertically mounted differential pressure sensors (connection nipples pointing down). The sensor is calibrated at the factor in the vertical position. As a consequence, the sensor must be installed in the vertical position. For horizontal installation (housing cover top or bottom), deviations occur to measured values that negate the measured values on the certificate. Disposal The devices are considered electronics devices for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic waste. • Dispose of the device via the channels provided for this purpose. • Comply with all local and currently applicable laws and regulations. Technical data Power supply Safety extra low voltage (SELV/PELV) or class 2 (UL) QBM4000-... 3-wire connection Operating voltage AC 24 V ± 15 %, 50 / 60 Hz or DC 13.5...33 Power consumption < 0.5 VA Current draw < 10 mA External supply line protection Fuse slow max. 10 A or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 or Power source with current limitation of max. 10 A Output signal DC 0...10 V, RLast > 10 kΩ (not galvanically separated, 3-wire connection, short-circuit proof, protected against reverse polarity) QBM4000-... 2-wire connection Operating voltage for ohm loads up to 500 Ω. Power consumption Product data DC 8...33 V DC 18…33 V < 0.7 VA Current draw 4...20 mA Output signal 4...20 mA supply voltage − 8 V Rload < [Ω] 0,02 A 2-wire technology, short-circuit proof, protected against reverse polarity). Measuring range refer to "Type summary" Sensing element Piezo-resistive (silicone membrane, ceramic bar) Degree of measuring accuracy at required (FS = Full Scale) installation position and room temperature 25 °C. 4/6 Siemens Building Technologies Differential pressure sensor QBM4000…/ QBM4100… CE1N1919en01 2014-07-30 QBM4100-1U Sum from zero point, linearity, reproducible and hysteresis. <±3 % FS (<±3 Pa) TC zero point <±0,1 % FS/°C TC sensitivity <±0,06 % FS/°C QBM4000-1 Zero point <±1.0 % FS QBM4100-1D Sum from linearity, reproducible and hysteresis. <±2 % FS TC zero point <±0.1 % FS/°C TC sensitivity <±0.06 % FS/°C QBM4000-3 Zero point <±0.7 % FS QBM4000-10 Sum from linearity, reproducible and hystere- QBM4000-25 sis. <±1 % FS TC zero point <±0.05 % FS/°C TC sensitivity <±0.05 % FS/°C Long-term stability ±1.0% FS as per DIN IEC 60 770 Response time < 2 0 ms Load change <10 Hz Tolerable overload on one side on P1. 5,000 Pa (10,000 Pa for types QBM4000 -10, -25) At P2 400 Pa Rupture pressure at room temperature 2 × overload at 70 °C 1.5 × overload Display (QBM4100-1D only) LCD, 2-line, 8 position each, alphanumeric, not background lit Display of: Media Admissible medium temperature. Degree of protection Differential pressure in Pa. Air and slightly aggressive gases 0...70 °C Maintenance Maintenance free Protection degree of housing at recommended IP54 according to EN 60529 installation Connections Protection class III according to EN 60730-1 Electrical connections 3-pin round plug with screw terminals 1.5 mm2 (Lumberg RKC 30 / 11) Pressure connections PVC nipples ∅ 6.2 mm, under pressure side is designated as 'P2' or ' – '. Environmental conditions Directives, standards Permissible ambient temperature Operation 0...70 °C Transport and storage. -25...+ 70 °C Permissible ambient humidity < 90 % r.h. (without condensation). Product standard EN 61326-1 Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements EU Conformity (CE) CE1T1910xx_01 *) RCM Conformity CE1T1910en_C1 *) UL 60730-1 / UL 60730-2-6 http://ul.com/database Environmental compatibility Dimensions (weight) The product environmental declaration CE1E1916*) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Weight (with packaging) 0.250 kg (with round plug connector). Weight (with packaging), with display 0.263 kg (with round plug connector). *) The documents can be downloaded from http://siemens.com/bt/download. 5/6 Siemens Building Technologies Differential pressure sensor QBM4000…/ QBM4100… CE1N1919en01 2014-07-30 Connectors QBM4000-.. Front view of the plug on the sensor housing (internally wired at the factory) or the view of the connection side of the cable plug. Terminal assignment Operating voltage AC 24 V (SELV) or DC 13.5…33 V. Output signal DC 0...10 V (reference point M) GND QBM4100-1. Front view of the plug on the sensor housing (internally wired at the factory) or the view of the connection side of the cable plug. Terminal assignment Supply voltage DC 8…33 V. Output signal DC 4…20 mA. 49 Dimensions 5,5 P2 9,6 16,3 P2 80 92 1919M01 86 18 P2 ø 6,2 P1 11 75 27,6 37 80 Dimensions in mm 6/6 Siemens Building Technologies 2005 - 2014 Siemens Switzerland Ltd Differential pressure sensor QBM4000…/ QBM4100… Subject to change CE1N1919en01 2014-07-30