Static differential pressure transducers X X Static 4.2 – differential pressure transducers testregistrierung Differential pressure transducers for volume flow rate measuring units Type Static differential pressure transducers 4 For the static effective and differential pressure measurement Differential pressure transducers based on the static measurement principle for volume flow rate measuring units Type VMR, VMRK or VME ■ Linear volume flow rate actual value 2 – 10 V DC ■ Recording of measured values for the display of volume flow rates or for the control of slave controllers ■ Parameters are factory set Universal controller VRP 05/2015 – DE/en K5 – 4.2 – 5 Differential pressure transducers for volume flow rate measuring units General information Static differential pressure transducers Type Page Static differential pressure transducers Description Universal controller VRP 4 Any attachments must be defined with the order code of the volume flow rate measuring unit. 4.2 – 6 4.2 – 7 Basic information and nomenclature 4.3 – 1 Application – Electronic volume flow controller Universal with static differential pressure transducer for use with volume flow rate measuring units – For applications with polluted extract air, e.g. with fluff, sticky particles or aggressive substances – Parameters are factory set – On-site adjusting is not required – For this application the Universal controller is only used for measuring the differential pressure and for transforming the measured value into a linear voltage signal. Connections for setpoint value signal and actuator are not relevant, and neither are the corresponding technical data. – Volume flow rate actual value is available as linear voltage signal Installation and commissioning – Installation orientation is relevant – Zero point correction required Maintenance – Zero point correction once per year is recommended Static differential pressure transducers for volume flow rate measuring units Order code detail Controller Part number BB0 Function General information Special information – BB0 M546EG2 Volume flow rate measuring unit Static differential pressure transducer Type Part number VRP M546EJ1 Type VFP-300 VMR, VME, VMRK Functional description The volume flow rate is determined by measuring the effective pressure. For this reason the measuring unit is fitted with an effective pressure sensor. The static differential pressure transducer (diaphragm pressure transducer) transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (nom). Principle of operation – static differential pressure transducer ݑ + ̋ ݢ ݤ ݣ ① Differential pressure transducer ② Volume flow controller ③ Actual value signal K5 – 4.2 – 6 05/2015 – DE/en Differential pressure transducers for volume flow rate measuring units Special information – BB0 Static differential pressure transducers Description / BB0 Order code detail Application – Electronic volume flow controller VRP with static differential pressure transducer for use with volume flow rate measuring units – Separate casings for differential pressure transducer and controller electronics Signal voltage range – 2 – 10 V DC Technical data Installation and commissioning – Installation orientation is relevant – Zero point correction required Maintenance – Zero point correction once per year is recommended Volume flow controller VRP Supply voltage (AC) Power rating (AC) Setpoint value signal input Actual value signal output IEC protection class Protection level EC conformity 24 V AC ± 20 %, 50/60 Hz without actuator max. 2.6 VA 2 – 10 V DC, Ra >100 kΩ 2 – 10 V DC linear, max. 0.5 mA III (protective extra-low voltage) IP 42 EMC according to 2004/108/EC 4 Universal controller VRP Static differential pressure transducer VFP-300 Supply voltage Measuring range Linearity IEC protection class Protection level EC conformity from the controller 0 – 300 Pa ± 3 Pa III (protective extra-low voltage) IP 42 EMC according to 2004/108/EC Static differential pressure transducer VFP-300 05/2015 – DE/en K5 – 4.2 – 7 Differential pressure transducers for volume flow rate measuring units Special information – BB0 Static differential pressure transducers Function VRP VFP-300 ݣ ݤ ݢ ݣ ݦ ݥ ① Controller VRP ② min potentiometer ③ max potentiometer ④ Cable for differential pressure transducer ⑤ Actuator cable Characteristics ① Connecting cable to Universal controller ② Tube connection for effective pressure sensor Characteristic of the actual value signal Terminal connections ݑNenn (100%) 1 ͛ Einstellbereich Wiring Volumenstrom 4 ݢ ݑmin Gerät 0 10 V DC 2 Istwertsignal U5 2 ~ 3 4 5 Íˣ Íˤ U5 6 y 7 z Universal ݢ ݣ ① Plug connection for differential pressure transducer VFP ② Plug connection for actuator 1 ⊥: Ground, neutral 2 ~: Supply voltage 3 w₁: Setpoint value signal 4 w₂: Setpoint value signal (0 – 20 V phase cut) 5 U5: Actual value signal 6 y: Actuator signal 7 z: Override control Universal: VRP 2 – 10 V DC ݑIst = U5 ̋ 2 ݑNenn 8 K5 – 4.2 – 8 05/2015 – DE/en 4.3 – X X Grundlagen und Definitionentestregistrierung Volume flow rate measurement Basic information and nomenclature 4 ■ Product selection ■ Principal dimensions ■ Nomenclature ■ Construction ■ Sizing and sizing example 05/2015 – DE/en K5 – 4.3 – 1 Volume flow rate measurement Basic information and nomenclature Product selection Type VMR VME VMRK VMLK Supply air ● ● ● ● Extract air ● ● ● ● ● ● Type of system Duct connection Circular ● Rectangular ● Volume flow rate range Up to [m³/h] 6048 36360 6048 1854 Up to [l/s] 1680 10100 1680 515 Filtered ● ● ● ● Office extract air ● ● ● ● Polluted ○ ○ ● ● Contaminated ○ ○ ● ● Manually ● ● ● Automatically ○ ○ ○ ● ● ● ● ● Air quality Volume flow rate measurement 4 Special areas Labs, clean rooms, operating theatres (EASYLAB, TCU-LON II) ● ○ Possible Possible under certain conditions: Robust unit variant and/or specific differential pressure transducer Not possible K5 – 4.3 – 2 05/2015 – DE/en Volume flow rate measurement Basic information and nomenclature Principal dimensions Nomenclature Constructions ØD [mm] VAV terminal units made of stainless steel: Outside diameter of the spigot VAV terminal units made of plastic: Inside diameter of the connecting spigot B₂ [mm] Outside dimension of flange (width) ØD₁ [mm] Pitch circle diameter of flanges H [mm] Duct height ØD₂ [mm] Outside diameter of flanges H₁ [mm] Screw hole pitch of flange (vertical) ØD₄ [mm] Inside diameter of the screw holes of flanges H₂ [mm] Outside dimension of flange (height) L [mm] Length of unit including connecting spigot H₃ [mm] Unit height L₁ [mm] Length of casing or acoustic cladding n[] Number of flange screw holes B [mm] Duct width T [mm] Flange thickness B₁ [mm] Screw hole pitch of flange (horizontal) m [kg] Weight including attachments for the automatic differential pressure measurement nom [m³/h] and [l/s] Nominal volume flow rate (100 %) K value [m³/h] and [l/s] Unit-related constant for air density 1.2 kg/m³ min [m³/h] and [l/s] Volume flow rate Δpw [Pa] Effective pressure Δ [± %] Volume flow rate accuracy Δpst [%] Static differential pressure in relation to the measured effective pressure Galvanised sheet steel – Casing made of galvanised sheet steel – Parts in contact with the airflow as described for the product type – External parts, e.g. mounting brackets or covers, are usually made of galvanised sheet steel Stainless steel (A2) – Casing made of stainless steel 1.4201 – Parts in contact with the airflow are powder-coated or made of stainless steel – External parts, e.g. mounting brackets or covers, are usually made of galvanised sheet steel B₃ [mm] Width of device Powder-coated surface (P1) – Casing made of galvanised sheet steel, powder-coated RAL 7001, silver grey – Parts in contact with the airflow are powder-coated or made of plastic – Due to production, some parts that come into contact with the airflow may be stainless steel or aluminium, powder-coated – External parts, e.g. mounting brackets or covers, are usually made of galvanised sheet steel 05/2015 – DE/en K5 – 4.3 – 3 4 Volume flow rate measurement Basic information and nomenclature Sizing with the help of this catalogue This catalogue provides convenient quick sizing tables for volume flow rate measuring unit, based on aerodynamic data. Volume flow rate ranges are provided for all nominal sizes. Sizing example Given data max = 280 l/s (1010 m3/h) Quick sizing VMR/200 C = 25.5 l/s (92 m3/h) ∆pst = 19 % ∆pw = 121 Pa ∆pst = 23 Pa (121 Pa × 0,19) Easy Product Finder 4 The Easy Product Finder allows you to size products using your project-specific data. You will find the Easy Product Finder on our website. K5 – 4.3 – 4 05/2015 – DE/en