08.00 GENERAL DISTRIBUTION SURGE ARRESTERS CUTOUTS AND ARRESTERS GENERAL 08.00-01 08.00-03 08.01 CUTOUTS AND ARRESTERS ARRESTERS, 10KV APPLICATION OF DIRECT CONNECTED ARRESTERS ON DISTRIBUTION TRANSFORMERS CUTOUTS AND BRACKETS CUTOUTS AND ARRESTERS 2 OR 3 EACH ON TRIPLE MOUNTING BRACKET CUTOUTS AND ARRESTERS SINGLE-PHASE TERMINATION ON POLE MOUNTED "L" BRACKET CUTOUT AND ARRESTER, (2) OR (3)-PHASE TERMINATION ON TRIPLE MOUNTING BRACKET SLACKSPAN WITH FUSED CUTOUT VERTICAL DOUBLE DEADEND WITH CUTOUTS VERTICAL CONSTRUCTION WITH LIGHTNING ARRESTER DOUBLE CIRCUIT CONSTRUCTION WITH LIGHTNING ARRESTER HORIZONTAL CONSTRUCTION TO HORIZONTAL DEADEND HORIZONTAL CONSTRUCTION TO HORIZONTAL WITH CUTOUT (FLYING TAP) HORIZONTAL CONSTRUCTION TO BRANCH LINE HORIZONTAL CONSTRUCTION WITH LIGHTNING ARRESTER SINGLE-PHASE CONSTRUCTION - FUSED TAP VERTICAL CONSTRUCTION - TANGENT FUSED TAP CONSTRUCTION 08.04 SECTIONALIZERS ELECTRONIC RESETTABLE SECTIONALIZERS 08.05 RECLOSERS - SINGLE-PHASE CONFIGURATIONS RECLOSERS, SECTIONALIZERS, TRANSFERS AND THREE-PHASE RECLOSER LIGHTNING ARRESTER MOUNTING DETAIL RECLOSER IDENTIFICATION TYPICAL SINGLE-PHASE RECLOSER DIMENSIONS, WEIGHTS AND OIL CAPACITIES COOPER RECLOSERS OPERATING LEVERS RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION OIL CIRCUIT RECLOSER - SINGLE-PHASE INSTALLATION BYPASS CUTOUT BRACKET RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION, FEEDER RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION, FEEDER RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION SLACK SPAN TAP RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION SLACK SPAN TAP OIL CIRCUIT RECLOSERS, THREE-PHASE INSTALLATION, HORIZONTAL CONSTRUCTION SINGLE-PHASE UNITS OIL CIRCUIT RECLOSERS, THREE-PHASE INSTALLATION, HORIZONTAL CONSTRUCTION SINGLE-PHASE UNITS 08.06 RECLOSERS - THREE-PHASE CONFIGURATIONS RECLOSER AND FRAME, THREE-PHASE, ABB WITH VERTICAL BYPASS SWITCH RECLOSER ASSEMBLY, THREE-PHASE, ABB WITH VERTICAL BYPASS SWITCH ABB RECLOSER ON VERTICAL DOUBLE CIRCUIT WITH VERTICAL BYPASS SWITCH RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH RECLOSER ASSEMBLY, THREE-PHASE, VIPER ST WITH VERTICAL BYPASS SWITCH RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH - 25KV CONSTRUCTION RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH - 25KV CONSTRUCTION ASSEMBLY, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH 25KV CONSTRUCTION DOUBLE CIRCUIT, THREE-PHASE, VIPER ST DOUBLE CIRCUIT, THREE-PHASE, VIPER ST VIPER RECLOSER HORIZONTAL CONSTRUCTION VIPER RECLOSER HORIZONTAL CONSTRUCTION WIRING DIAGRAM FOR PT CLUSTER FOR G&W VIPER WIRING DIAGRAM FOR PT CLUSTER ABB 1PT TO 3PT CONVERSION FUSE AND BATTERY FOR SEL 651-R2 CONTROLS (ABB & VIPER) FUSE AND BATTERY FOR SEL 651-R2 CONTROLS (ABB & VIPER) SPECIAL PROVISIONS - G&W VIPER ST, IPP INTERCONNECTION ABB TO SEL 651-R2 CONTROL CONVERSION ON ABB RECLOSERS ABB TO SEL 651-R2 CONTROL CONVERSION ON ABB RECLOSERS RECLOSER ASSEMBLY, THREE-PHASE, VERTICAL, 600 AMP SWITCH RECLOSER ASSEMBLY, THREE-PHASE, VERTICAL, 600 AMP SWITCH 5 4/18/16 KATIGBAK BURLISON ADCOCK 4 12/16/15 KATIGBAK BURLISON ADCOCK 3 12/19/14 KATIGBAK GUINN ADCOCK 0 11/30/10 CECCONI GUINN ELKINS BY CK'D APPR. REVISED 08.01-01 08.01-04 08.01-10 08.01-11 08.01-12 08.01-13 08.01-14 08.01-16 08.01-28 08.01-29 08.01-32 08.01-33 08.01-36 08.01-37 08.01-38 08.01-39 08.04-02 08.05-00 08.05-01 08.05-02 08.05-06 08.05-15A 08.05-15B 08.05-16A 08.05-16B 08.05-18A 08.05-18B 08.05-114A 08.05-114B 08.06-08A 08.06-08B 08.06-10 08.06-11A 08.06-11B 08.06-11C 08.06-12A 08.06-12B 08.06-12C 08.06-13A 08.06-13B 08.06-14A 08.06-14B 08.06-15A 08.06-15B 08.06-15C 08.06-15D 08.06-15E 08.06-16A 08.06-16B 08.06-22A 08.06-22B DEC DEM DEP DEF SECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS X 08.00-00A 08.10 SWITCHES - MANUAL BYPASS SWITCHES SWITCH MOUNTING IN VERTICAL DOUBLE CIRCUIT SWITCH MOUNTING IN VERTICAL DOUBLE CIRCUIT 600 AMP DOUBLE CIRCUIT TIE SWITCH 600 AMP DOUBLE CIRCUIT TIE SWITCH SWITCH ASSEMBLY, 300 AMP, SOLID BLADE, VERTICAL SWITCH ASSEMBLY, 600 AMP, SOLID BLADE, VERTICAL SWITCH ASSEMBLY, 600 AMP, SOLID BLADE, VERTICAL SWITCH ASSEMBLY, 300 AMP, SOLID BLADE HORIZONTAL SWITCH ASSEMBLY, 600 AMP, SOLID BLADE HORIZONTAL 600 AMP INLINE DISCONNECT VERTICAL TANGENT CROSSING WITH 600 AMP DISCONNECTS 08.10-10 08.10-12A 08.10-12B 08.10-14A 08.10-14B 08.10-16 08.10-18A 08.10-18B 08.10-20 08.10-22 08.10-24 08.10-26 08.12 SWITCHES - LOAD CONTROL VLR LOAD CONTROL SWITCH VLR LOAD CONTROL SWITCH VERSAVAC LOAD CONTROL VERSAVAC LOAD CONTROL CONNECTION DIAGRAM FOR VERSAVAC SWITCH LOAD CONTROL SWITCH 600 AMP LOAD CONTROL SWITCH 600 AMP 08.12-02A 08.12-02B 08.12-04A 08.12-04B 08.12-04C 08.12-06A 08.12-06B 08.13 SWITCHES - AUTOMATED OVERHEAD AUTOMATIC TRANSFER SCHEME VLR TYPE S TRANSFER CONTROL AUTOMATIC TRANSFER SWITCH ASSEMBLY, (VLR), CONTROL WIRING DETAIL SCADA MATE CX SWITCH STANDARD MOUNTING ARRANGEMENT SCADA MATE CX SWITCH STANDARD MOUNTING ARRANGEMENT SCADA MATE CX SWITCH STANDARD MOUNTING ARRANGEMENT OMNI-RUPTER SWITCH CONTROL FACEPLATE ANTENNA INSTALLATION FOR VERTICAL OMNI-RUPTER SWITCH 08.13-01 08.13-03 08.13-05 08.13-08A 08.13-08B 08.13-08C 08.13-10D 08.13-10E FOR MAINTENANCE ONLY DRAWINGS THE FOR MAINTENANCE ONLY DRAWINGS LISTED BELOW ARE NOT CONTAINED IN THE PRINTED SPEC BOOK, BUT ARE AVAILABLE ONLINE VERTICAL CONSTRUCTION TO VERTICAL CONSTRUCTION WITH WITH OIL SECTIONALIZER (FMO) SECTIONALIZER ASSEMBLY, OIL TYPE, VERTICAL (FMO) RECLOSER ASSEMBLY, HORIZONTAL CONSTRUCTION (FMO) RECLOSER ASSEMBLY, HORIZONTAL CONSTRUCTION (FMO) HORIZONTAL CONSTRUCTION TO HORIZONTAL CONSTRUCTION WITH OIL SECTIONALIZER (FMO) RECLOSER ASSEMBLY, THREE-PHASE, HORIZONTAL 600 AMP SWITCH (FMO) LOAD CONTROL SWITCH ASSEMBLY, (VLR), THREE-PHASE HORIZONTAL WITH 600 AMP BYPASS (FMO) OMNI-RUPTER SWITCH STANDARD MOUNTING ARRANGEMENT (FMO) OMNI-RUPTER SWITCH STANDARD MOUNTING ARRANGEMENT (FMO) OMNI-RUPTER SWITCH STANDARD MOUNTING ARRANGEMENT (FMO) OMNI-RUPTER SWITCH STANDARD STACKED DOUBLE-CIRCUIT POLE ARRANGEMENT (FMO) OMNI-RUPTER SWITCH STANDARD STACKED DOUBLE-CIRCUIT POLE ARRANGEMENT (FMO) OMNI-RUPTER SWITCH HORIZONTAL MOUNTING ARRANGEMENT (FMO) OMNI-RUPTER SWITCH HORIZONTAL MOUNTING ARRANGEMENT (FMO) OMNI-RUPTER SWITCH HORIZONTAL MOUNTING ARRANGEMENT (FMO) INTELLITEAM RADIO TRANSCEIVERS (FMO) 4 1/6/16 KATIGBAK BURLISON ADCOCK 3 8/27/15 KATIGBAK BURLISON ADCOCK 2 9/26/14 KATIGBAK GUINN ADCOCK 0 12/1/10 CECCONI GUINN ELKINS BY CK'D APPR. REVISED 08.04-06 08.04-08 08.05-17A 08.05-17B 08.04-12 08.06-12 08.12-06 08.13-10A 08.13-10B 08.13-10C 08.13-11A 08.13-11B 08.13-13A 08.13-13B 08.13-13C 08.13-15 DEC DEM DEP DEF SECTION 8 - SWITCHES AND PROTECTIVE DEVICES TABLE OF CONTENTS X 08.00-00B STANDARD PROCEDURES BULLETIN STANDARD DISTRIBUTION ARRESTERS: THE STANDARD DISTRIBUTION ARRESTER IS A DIRECT-CONNECTED METAL OXIDE ARRESTER WITH A GROUND LEAD DISCONNECTOR ( DWG. 08.01-04 FOR DISCONNECTOR PROCEDURES). METAL OXIDE ARRESTERS (MOV) HAVE BEEN PURCHASED SINCE 1984 AND OFFER THE BEST AVAILABLE PROTECTION AGAINST LIGHTNING AND SWITCHING SURGES. BY DESIGN, THE MOV ARRESTER CONDUCTS A SMALL LEAKAGE CURRENT (MILLIAMPS) TO GROUND UNDER NORMAL VOLTAGE CONDITIONS. SINCE 1990, ALL OF OUR MOV ARRESTERS HAVE BEEN PURCHASED WITH POLYMER HOUSINGS. THE ADVANTAGE OF THE POLYMER HOUSING IS THAT IT IS DESIGNED TO RETAIN THE BLOCKS DURING A CATASTROPHIC FAILURE MODE. THESE MOV ARRESTERS ARE AVAILABLE IN THREE DIFFERENT CLASSIFICATIONS AS FOLLOWS: RISER POLE ARRESTERS ARE USED ON PRIMARY UNDERGROUND CABLE RISERS. THESE ARRESTERS NORMALLY CONTAIN LARGER BLOCKS THAN STANDARD DISTRIBUTION ARRESTERS TO PROVIDE ADDITIONAL PROTECTION FOR THIS APPLICATION. THESE ARRESTERS ARE LABELED WITH THE WORDS "RP" AND THE VOLTAGE CLASS. STANDARD DISTRIBUTION ARRESTERS ARE USED FOR OVERHEAD LINE AND EQUIPMENT PROTECTION. WHILE THEY DO NOT HAVE A SPARK OVER VOLTAGE AS LOW AS THE RISER POLE ARRESTER, THEY PROVIDE AN ECONOMICAL BIL MARGIN OF PROTECTION EXCEEDING THE OLD SILICONE CARBIDE ARRESTER. TRANSFORMER ARRESTERS ARE IDENTICAL TO THE STANDARD DISTRIBUTION ARRESTER. THEY ARE CATALOGED DIFFERENTLY TO INCLUDE A CONNECTION LEAD AND A GROUND STRAP TO CONNECT IT TO A TRANSFORMER. SILICONE CARBIDE ARRESTERS HAVE NOT BEEN PURCHASED SINCE 1984. THESE ARRESTERS CAN BE FOUND ON THE SYSTEM WITH INTERNAL OR EXTERNAL GAP STRUCTURES. ALL SILICONE CARBIDE ARRESTERS HAVE PORCELAIN HOUSINGS. INTERNAL GAP ARRESTERS CONTINUE TO PROVIDE GOOD SURGE PROTECTION FOR THE SYSTEM AND SHALL CONTINUE TO BE USED UNTIL THEY ARE REMOVED FOR ANY REASON. ONCE REMOVED, THEY SHALL BE SCRAPPED. EXTERNAL GAP ARRESTERS THAT ARE REMOVED SHALL BE SCRAPPED. INSTALLATION PRACTICES: 1. ARRESTER LEAD LENGTHS (BOTH LINE AND GROUND LEADS) SHALL BE AS SHORT AND AS STRAIGHT AS POSSIBLE. THIS PROVIDES THE BEST PROTECTION BY MINIMIZING THE SURGE VOLTAGE DURING ARRESTER OPERATION. DO NOT COIL TRANSFORMER RISERS. 2. GROUND RODS SHALL BE INSTALLED AT ALL POLES CONTAINING ARRESTERS ACCORDING TO THE STANDARD PROCEDURES OUTLINED ON DWGS. 01.01-01A , 01.01-01B, 01.01-01C AND 01.01-05. ARRESTER APPLICATIONS 1. EQUIPMENT PROTECTION (GROUND PER DWGS. 01.01-01A , 01.01-01B, 01.01-01C AND 01.01-05) ALL TRANSFORMERS, RECLOSERS, CAPACITOR BANKS, VOLTAGE REGULATORS, AND OTHER EQUIPMENT SHALL HAVE ARRESTERS INSTALLED AS SHOWN ON THE APPROPRIATE SPECIFICATION DRAWINGS CONTAINED HEREIN. 2. LINE PROTECTION A. ALL NORMAL OPEN POINTS SHALL HAVE ARRESTERS INSTALLED ON EACH PHASE ON BOTH SIDES (NORMAL SOURCE AND LOAD). ARRESTERS MAY BE MOUNTED ON POLE ADJACENT TO SWITCHES. B. INSTALL ARRESTERS AT DEADENDS UNLESS PROTECTED BY EQUIPMENT ARRESTER. C. INSTALL ARRESTERS EVERY 1400' TO 1600' UNLESS THERE ARE ARRESTERS PRESENT. ALSO, AREAS WITH TALL TREES AND/OR BUILDINGS ALONG SIDE THE LINE ARE SHIELDED AND MIGHT REQUIRE LESS REQUIRE LESS ARRESTERS AS PER ENGINEER'S JUDGMENT. 3 DEC DEM DEP DEF 2 1 3/31/15 LOOSIER WHITE ADCOCK 0 8/16/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED X DISTRIBUTION SURGE ARRESTERS 08.00-01 GENERAL ON WOOD POLE CONSTRUCTION USE SINGLE COIL LOCKWASHER AND SQUARE WASHERS WITH CUTOUT, ARRESTER AND SWITCH BRACKETS. CUTOUTS 1. BYPASS FUSE HOLDERS OR NORMALLY OPEN CUTOUT DOORS SHOULD BE HUNG BY THEIR OPERATING RINGS SO THE BARRELS WILL NOT FILL UP WITH WATER. 2. A TRANSFORMER STEM CONNECTOR MAY BE USED WHEN 1/0 OR SMALLER ALUMINUM WIRE IS RUN DIRECTLY INTO THE CUTOUT. 3. WHEN ADDING CUTOUTS TO EXISTING VERTICAL CONSTRUCTION, THE PHASE TO PHASE SPACING SHOULD BE 42 INCHES FOR 23KV. ARRESTERS 1. ARRESTERS SHALL BE INSTALLED ON BOTH SIDES OF ANY NORMAL OPEN PRIMARY SWITCH DEVICE WHICH CAN BE SOURCE FED FROM BOTH DIRECTIONS. 2. THE PRIMARY ARRESTER TAP SHOULD BE #6 BARE SOFT DRAWN SOLID COPPER WIRE. 3. ARRESTERS SHALL BE POSITIONED SUCH THAT A BLOWN DISCONNECTOR/ISOLATOR WILL NOT AFFECT OTHER ENERGIZED EQUIPMENT. 4. ARRESTERS SHALL BE INSTALLED ON THE SOURCE AND LOAD SIDE OF RECLOSERS AND REGULATORS. 5. AT VOLTAGE REGULATOR INSTALLATIONS, INSTALL THE LIGHTNING ARRESTERS ON THE REGULATOR, IF POSSIBLE. IF NOT POSSIBLE, MOUNT THE ARRESTERS AS CLOSE TO THE SOURCE AND LOAD BUSHINGS AS POSSIBLE. 6. THE PRIMARY ARRESTER TAP CONNECTION CAN BE MADE WITH ALUMINUM HOT LINE ARRESTER CLAMPS. STIRRUPS ARE NOT REQUIRED FOR ARRESTERS. 7. KEEP ARRESTER TAP AND GROUND LEADS AS SHORT AS POSSIBLE. THIS PROVIDES GREATER EQUIPMENT PROTECTION. 8. AN ARRESTER SHOULD BE USED TO PROTECT ANY PHASE THAT HAS A GROUND WIRE EXTENDING PAST IT, EXCEPT ON CONCRETE OR STEEL POLES. 9. ON UNDERGROUND SUBSTATION EXITS, DISTRIBUTION CLASS RISER POLE ARRESTERS SHALL BE LOCATED ON THE TERMINAL POLE OUTSIDE THE SUBSTATION AND ON THE TERMINAL POLE IN THE SUBSTATION. 10. RISER POLE ARRESTERS SHALL BE USED ON ALL OVERHEAD TO UNDERGROUND DIP POLES. 11. INSTALL ARRESTERS EVERY 1400' TO 1600' UNLESS THERE ARE ARRESTERS PRESENT. ALSO, AREAS WITH TALL TREES AND/OR BUILDINGS ALONG SIDE THE LINE ARE SHIELDED AND MIGHT REQUIRE LESS ARRESTERS AS PER ENGINEER'S JUDGMENT. 12. CONCRETE OR METAL TRANSMISSION AND DISTRIBUTION POLES: INSULATE WITH 35KV INSULATORS AND APPLY LIGHTNING ARRESTERS ON ALL PHASES EVERY 550'. 3 DEC DEM DEP DEF X X X X 2 1 3/31/15 LOOSIER WHITE ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED CUTOUTS AND ARRESTERS GENERAL 08.00-03 3 1 2 4 BILL OF MATERIALS MACRO UNIT - CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 AREQOH10F 1 2 BKTCOLASTLXARMF 1 3 BKTCOLASNGSTLF 1 4 BKTCOLADBLSTLF 1 CATALOG NUMBER 193511 220202 070101 311263 152106 013264 013308 070106 152106 013264 013308 QTY PER CU 2 1 1 1 2 2 2 1 2 2 2 DESCRIPTION CABLE, 600V #6 SOLID SD CU ARRESTER, LIGHTNING, 10KV, HD MOV BRACKET, ARRESTER AND CUTOUT BRACKET, SINGLE MOUNT BOLT, MACHINE, 5/8" X 10" WASHER, SPRING COIL, 5/8" WASHER, 2-1/4" SQUARE BRACKET, DOUBLE LIGHTNING ARR & CO BOLT, MACHINE, 5/8" X 10" WASHER, SPRING COIL, 5/8" WASHER, 2-1/4" SQUARE NOTES: 1. CAUTION: DO NOT TIGHTEN TOP NUT ON ARRESTERS WITH AN AIR OR HYDRAULIC SPEED WRENCH. OVER-TORQUING CAN EASILY OCCUR USING THESE WRENCHES RESULTING IN A BROKEN CONTACT INSIDE THE ARRESTER HOUSING. 3 2 ARRESTERS, 10 KV 1 0 8/31/10 REVISED R HOFFMAN GUINN ELKINS DWG. BY CK'D APPR. 08.01-01 PRIMARY RISER ISOLATOR CAUTION: MAY BE ENERGIZED AT PRIMARY VOLTAGE GROUND STRAP GROUNDED ROTATE ARRESTER TO BE STRAIGHT OUT FROM TANK PROPERLY INSTALLED ARRESTER FAILED ARRESTER NOTES: 1. DIRECT CONNECTED ARRESTER LEADS ARE FURNISHED WITH AN EYE TERMINAL. THE LEAD IS TO BE CONNECTED BETWEEN THE ARRESTER AND THE PRIMARY BUSHING TERMINAL WITH THE EYE TERMINAL BETWEEN THE NUT AND THE TERMINAL, AND ARRANGED SO AS NOT TO INTERFERE WITH THE PRIMARY RISER 2. IN THE EVENT OF AN ARRESTER FAILURE, THE ISOLATOR WILL OPERATE AND DISCONNECT THE GROUND LEAD, THUS PREVENTING AN INTERRUPTION TO THE CIRCUIT. ALL FAILED ARRESTERS ARE TO BE REPORTED TO THE LOCAL OPERATIONS CENTER. THE ARRESTER IS TO BE CHANGED OUT AS SOON AS POSSIBLE AFTER BEING REPORTED. 3. ON NEW POLE MOUNTED SINGLE-PHASE TRANSFORMERS, THE TRANSFORMER IS SHIPPED WITH THE LIGHTNING ARRESTER ROTATED UP AGAINST THE TANK. THIS IS DONE TO PREVENT BREAKAGE OF THE ARRESTER DURING SHIPPING. BEFORE THE TRANSFORMER IS INSTALLED, THE ARRESTER MOUNTING BOLT SHOULD BE LOOSENED AND THE ARRESTER ROTATED UNTIL IT IS STRAIGHT OUT FROM THE TANK. IF THIS IS NOT DONE AND THE ARRESTER IS LEFT UP AGAINST THE TANK, IT WILL EVENTUALLY CAUSE MOMENTARY FEEDER OPERATIONS OR OUTAGES. 4. CAUTION: DO NOT TIGHTEN TOP NUT ON ARRESTERS WITH AN AIR OR HYDRAULIC SPEED WRENCH. OVERTORQUING CAN EASILY OCCUR USING THESE WRENCHES RESULTING IN A BROKEN CONTACT INSIDE THE ARRESTER HOUSING. 3 2 APPLICATION OF DIRECT CONNECTED ARRESTERS 1 0 7/11/10 REVISED GUINN GUINN ELKINS BY CK'D APPR. ON DISTRIBUTION TRANSFORMERS DWG. 08.01-04 2 3 1 5 4 C H A N C E CROSSARM MOUNTED CIRCUIT POLE MOUNTED CUTOUT FOR MAINTENANCE ONLY BILL OF MATERIALS MACRO UNIT - CU ITEM NO. 1 1 1 1 1 1 1 1 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER FUSE15CO100F TFUSE15CO100F FUSE27CO100F FUSE27CO100PF TFUSE27CO100F TFUSE27CO100PF FUSE27CO200F SW153COSBDF SW253COSBDF 1 1 1 1 1 1 1 1 1 2 BKTCOLASTLXARMF 1 3 BKTCOLASNGSTLF 1 4 BKTCOLADBLSTLF 1 5 5 SW153COSBDBOF SW253COSBDBOF 1 1 221112 221112 221139 9220090063 221139 9220090063 221143 9220210916 9220210993 070101 011213 311263 013264 013308 152106 070106 013264 013308 152106 269046 269043 QTY PER CU 1 1 1 1 1 1 1 1 1 1 2 1 2 2 2 1 2 2 2 1 1 DESCRIPTION CUTOUT, NONLOADBREAK, 15KV, 100A, 16KA, 110KV BIL CUTOUT, NONLOADBREAK, 15KV, 100A, 16KA, 110KV BIL CUTOUT, NONLOADBREAK, CUTOUT, 27KV, 100A, 12KA, 150KV BIL CUTOUT, SILICONE, 27KV, 100A, 12KA, 150KV BIL, SILICON CUTOUT, NONLOADBREAK, CUTOUT, 27KV, 100A, 12KA, 150KV BIL CUTOUT, SILICONE, 27KV, 100A, 12KA, 150KV BIL, SILICON CUTOUT, NONLOADBREAK, CUTOUT, 27KV, 200A, 10KA, 150KV BIL CUTOUT, BLADE, BLADE,SLD,NONLOADBREAK,300A,15 KV CUTOUT, BLADE, SLD, NONLOADBREAK BLADE,300A,25 KV, 150 KV BIL BRACKET, LA & CO TY A BOLT, CARRIAGE, 3/8 IN, 6 IN, CARBON STEEL, ASTM A153, CRG 3 BRACKET, .., SGL MT WASHER, .., SPRING,COIL,STEEL,FOR,5/8",BOLT,GALV. WASHER, SQUARE, 2-1/4",SQUARE,FLAT,13/16",HOLE,GALV. BOLT, MACHINE, 5/8 IN, 10 IN, STEEL, A-ASTM A307, GLV, MACH, BRACKET, .., ARSTR & CO,DBL MNTG WASHER, .., SPRING,COIL,STEEL,FOR,5/8",BOLT,GALV. WASHER, SQUARE, 2-1/4",SQUARE,FLAT,13/16",HOLE,GALV. BOLT, MACHINE, 5/8 IN, 10 IN, STEEL, A-ASTM A307, GLV, MACH, BLADE, CUTOUT, BLADE SOLID, CUTOUT, 15KV, 300A BLADE, CUTOUT, BLADE, SOLID, CUTOUT, 27KV, 300A NOTES: 1. USE FUSE (FUSE____F) FOR OVERHEAD AND UNDERGROUND LINE CUTOUTS. USE TFUSE ( TFUSE____F) FOR TRANSFORMER AND CAPACITOR BANKS. THIS ENSURES PROPER ACCOUNTING IN WMIS. 2. 27KV CUTOUTS ARE REQUIRED ON THE 25KV SYSTEM IN HOLOPAW, ON ALL CONCRETE POLES AND IN COASTAL/CONTAMINATED AREAS. 3. USE 100 AMP CUTOUT DOORS WITH 103 FUSE LINKS AND SMALLER. USE 200 AMP CUTOUT DOORS WITH 125, 150, AND 200 AMP FUSE LINKS. DO NOT USE 200 AMP CUTOUT DOORS WITH 103 OR SMALLER FUSES. 3 2 CUTOUTS AND BRACKETS R 1 2/6/12 BURLISON 0 10/12/10 HOFFMAN GUINN ELKINS DWG. BY CK'D APPR. 08.01-10 REVISED BURLISON ELKINS 1 2 BILL OF MATERIALS CU ITEM NO. 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER FUSE15CO100F 2 OR 3 2 BKTCOLATRISTLF 1 221112 070104 013264 013308 152107 QTY PER CU 1 1 2 2 2 DESCRIPTION CUTOUT, 15 KV 100A, 16KA ASYMMETRICAL BRACKET, LA, CUTOUT, 48" WASHER, SPRING COIL, 5/8" WASHER, 2-1/4" SQUARE BOLT, MACHINE, SQ, NUT, 5/8" X 12" 3 2 1 4/9/13 McCONNELL 0 8/30/10 GUINN GUINN ELKINS BY CK'D APPR. REVISED DANNA ADCOCK CUTOUTS AND ARRESTERS 2 OR 3 EACH ON TRIPLE MOUNTING BRACKET DWG. 08.01-11 1 3 4 CONNECTOR STEM INCLUDED WITH TERMINATOR KIT 2 BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER FUSE15CO100F 1 2 ARUGTP10F 1 3 BKTCOLASNGSTLF 1 4 KHLC40N6F 1 221112 220208 153534 311263 013264 013308 152106 9220184790 CA1T15FM OR CA2T15FM (TWO-PHASE) QTY PER CU 1 1 1 1 2 2 2 1 DESCRIPTION CUTOUT, LOADBREAK, 15KV, 100A, 16KA, 110KV BIL ARRESTER, LIGHTNING, RP, 10KV, FOR TRANSITION POLES, HD CONNECTOR, STEM, ARRESTER BRACKET, SGL MT WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, 5/8" X 10", STEEL, A-ASTM A307, GALV. CLAMP, HOT LINE, ALUM, SMALL, 4/0 NOTES: 1. CAUTION: DO NOT TIGHTEN TOP NUT ON ARRESTERS WITH AN AIR OR HYDRAULIC SPEED WRENCH. OVER-TORQUING CAN EASILY OCCUR USING THESE WRENCHES RESULTING IN A BROKEN CONTACT INSIDE THE ARRESTER HOUSING. 3 2 1 6/7/13 0 11/5/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. CUTOUTS AND ARRESTERS SINGLE-PHASE TERMINATION ON POLE MOUNTED "L" BRACKET DWG. 08.01-12 1 3 4 2 BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER FUSE15CO100F 3 2 ARUGTP10F 3 3 BKTCOLATR1STLF 1 4 KHLC40N6F 3 221112 220208 153534 070104 013264 013308 152106 9220184790 CA3T15FM QTY PER CU 1 1 1 1 2 2 2 1 DESCRIPTION CUTOUT, LOADBREAK, 15KV, 100A, 16KA, 110KV BIL ARRESTER, LIGHTNING, RP, 10KV, FOR TRANSITION POLES, HD CONNECTOR, STEM, ARRESTER BRACKET, LA AND CO TRI MNTG WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, 5/8" X 10", STEEL, A-ASTM A307, GALV. CLAMP, HOT LINE, ALUM, SMALL, 4/0 NOTES: 1. CAUTION: DO NOT TIGHTEN TOP NUT ON ARRESTERS WITH AN AIR OR HYDRAULIC SPEED WRENCH. OVER-TORQUING CAN EASILY OCCUR USING THESE WRENCHES RESULTING IN A BROKEN CONTACT INSIDE THE ARRESTER HOUSING. 3 2 1 6/7/13 0 11/5/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. CUTOUT AND ARRESTER, (2) OR (3) PHASE TERMINATION ON TRIPLE MOUNTING BRACKET DWG. 08.01-13 KHLC40N6F OR KHLC7933F #2 WP COPPER CU RCRISERN2CUF 5" 4" 4" 14" 6" 36" 14" 36" 14" 72" 4" NEUTRAL FRONT VIEW NOTES: 1. SEE DWG 03.06-04 FOR POST TYPE INSULATORS. 2. SEE DWG. 03.06-08 FOR PIN TYPE INSULATORS. 3. SEE DWG. 03.03-04 FOR SLACK SPAN CLAMPS. 4. SEE DWG. 03.16-00 FOR SLACK SPAN GRIPS. 3 DEC DEM DEP DEF 2 1 8/7/14 SALAS DANNA ADCOCK 0 11/9/12 HOFFMAN DANNA ADCOCK BY CK'D APPR. REVISED X SLACKSPAN WITH FUSED CUTOUT 08.01-14 SOURCE LOAD 5 PLAN VIEW 5" 36" 4 3 36" 2 1 4" 6" CL TOP BOLT OF BRACKET 72" NEUTRAL #6 SD BC FRONT VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 ISEYEBOLT5812F 3 2 3 4 5 ISEYENUT58F DECLMP(WIRE)F IDES(KV)F BKTCO18FGF 3 6 6 3 - ITEM NUMBER 11709 13346 12210 9220275817 QTY PER CU 1 1 1 1 1 1 DESCRIPTION BOLT, OVAL EYE, 5/8" X 12" WASHER, 3" SQ., CURVED, 13/16" HOLE INSULATOR SUPPORT EYENUT DEADEND CLAMP (WIRE) INSULATOR DEADEND SUSPENSION (KV) POLYMER BRACKET, STANDOFF, 1.5" RND X 18" LG IN, FIBERGLASS NOTES: 1. THIS DESIGN SPECIFICATION CAN ALSO BE APPLIED TO A SINGLE-PHASE CONFIGURATION. 3 DEC DEM DEP DEF 2 0 X VERTICAL DOUBLE DEADEND WITH CUTOUTS 1 8/10/15 REVISED LOOSIER BURLISON ADCOCK BY CK'D APPR. 08.01-16 TANGENT CONSTRUCTION DEADEND CONSTRUCTION CN 080212 PLAN VIEW CN 9220184790 OR CN 9220184794 PLAN VIEW 5" 8" 8" TYP. #6 WP COPPER CU ARRRISERN6CUF CN 9220218856 36" CN 220202 36" 4" TYP. TO GUY ATTACHMENT 8" 36" 36" #6 SD BC SEE NOTE 1 SEE NOTE 1 8" 72" 72" NEUTRAL NEUTRAL #6 SD BC FRONT VIEW #6 SD BC FRONT VIEW NOTES: 1. INSTALL GROUND AWAY FROM INSULATOR. 3 6/6/14 LOOSIER DANNA ADCOCK 2 5/24/13 McCONNELL DANNA ADCOCK 1 3/2/11 BURLISON BURLISON ELKINS 0 8/11/10 ROBESON GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP VERTICAL CONSTRUCTION WITH LIGHTNING ARRESTER DEF X 08.01-28 5" 4" TYP. 36" TOP BRACKET BOLT 36" 36" MIN. 10" PLAN VIEW 64" NEUTRAL FRONT VIEW NOTES: 1. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. 3 2 DOUBLE CIRCUIT CONSTRUCTION R 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. WITH LIGHTNING ARRESTER DWG. 08.01-29 6" 8" 18" KHLC40N6F OR KHLC7933F 16" 34" 8" 6" PLAN VIEW PLAN VIEW 8" 34" 16" 18" 8" 6" 4" 6" 4" 36" #2 WP COPPER CU RCRISERN2CUF 72" 78 "G U YS TI CK 6" 72" #6 SD BC NEUTRAL 4" #6 SD BC FRONT VIEW FRONT VIEW NOTES: 1. CUTOUTS WILL NORMALLY BE INSTALLED ON THE TAP POLE. 3 2 DEC 8/7/14 SALAS DANNA 1 8/31/11 BURLISON BURLISON ELKINS 0 8/11/10 ROBESON GUINN ELKINS BY CK'D APPR. REVISED ADCOCK DEM DEP HORIZONTAL CONSTRUCTION TO HORIZONTAL DEADEND DEF X 08.01-32 6" 16" 6" 16" NEUTRAL 42" 6" NEUTRAL PLAN VIEW #2 WP COPPER CU RCRISERN2CUF 36" KHLC40N6F OR KHLC7933F 62" GU YA TT AC HM EN T 6" NEUTRAL 4" #6 SD BC FRONT VIEW 3 2 8/7/14 SALAS DANNA ADCOCK 1 8/31/11 BURLISON BURLISON ELKINS 0 8/11/10 ROBESON GUINN ELKINS BY CK'D APPR. REVISED HORIZONTAL CONSTRUCTION TO HORIZONTAL WITH CUTOUT (FLYING TAP) DEC DEM DEP DEF X 08.01-33 TANGENT CONSTRUCTION DEADEND TO DEADEND SOURCE NEUTRAL LOAD PLAN VIEW PLAN VIEW KHLC40N6F OR KHLC7933F 6" 36" #2 WP COPPER CU RCRISERN2CUF TOP BOLT OF 'L' BKT 2" GUY ATTACHMENT AND 78" GUY STICK 72" 78 "G UY ST I CK 4" 72" FRONT VIEW NEUTRAL 4" FRONT VIEW 3 DEC 2 8/7/14 SALAS DANNA ADCOCK 1 8/31/11 BURLISON BURLISON ELKINS 0 8/11/10 ROBESON GUINN ELKINS BY CK'D APPR. REVISED DEM DEP HORIZONTAL CONSTRUCTION TO BRANCH LINE DEF X 08.01-36 IN-LINE CONSTRUCTION DEADEND CONSTRUCTION GUY ATTACHMENT PLAN VIEW PLAN VIEW 9" 4" 9" 35" 15" 20" 9" 4" 6" 9" 9" 24" 33" 6" 9" 5" 6" SEE DETAIL 'A' 62" GUY ATTACHMENT 72" #6 SD BC #6 SD BC FRONT VIEW FRONT VIEW #6 SD BC NOTES: 1. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. DETAIL 'A' 3 2 HORIZONTAL CONSTRUCTION WITH R 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. LIGHTNING ARRESTER DWG. 08.01-37 KHLC40N6F OR KHLC7933F TOP BRACKET BOLT 5" 3" #2 WP COPPER CU RCRISERN2CUF 6" 12" 3" BOTTOM BRACKET BOLT 4" IDES25PF 72" (SEE NOTE 5) 4" 4" CL OF BOLT HOLE #6 SD BC FRONT VIEW 12KV NOTES: 1. POLE GAINS ( ISGAINGRIDF FOR 15/25KV INSULATORS OR ISGAINGRID55F FOR 35KV INSULATORS) ARE REQUIRED FOR POST INSULATOR INSTALLATIONS ON WOOD POLES WHEN THE POLE DOES NOT HAVE A SLAB GAIN FOR ALL CONDUCTOR SIZES.WHEN THE CONDUCTOR IS 336.4 KCMIL OR LARGER, USE POLE GAIN EVEN IF SLAB GAIN EXISTS. POLE GAINS ARE NOT REQUIRED FOR INSULATORS USED FOR JUMPERS. SLACK SPANS WITH 336 AND 795 CONDUCTORS REQUIRE A POLE GAIN. 2. TYPICAL INSTALLATION: SEE SECTION 04 FOR NEUTRAL/SECONDARY DETAILS. 3. TYPICAL INSTALLATION: SEE SECTION 02 FOR GUYING DETAILS. 4. SEE DWG. 08.01-10 FOR BILL OF MATERIALS FOR CUTOUTS. 5. 72" NEUTRAL SPACING IS PREFERRED TO ACCOMMODATE MAINTENANCE AND SHOULD BE OBTAINED ON NEW CONSTRUCTION OR UPGRADE INVOLVING POLE REPLACEMENT. UPGRADES AND ADDITIONS ON EXISTING POLES MAY UTILIZE 60" NEUTRAL SPACING IF 72" SPACING CANNOT BE OBTAINED WITHOUT REPLACING THE POLE OR CAUSING CONFLICT WITH COMMUNICATION CABLES. 6. SEE DWG. 03.06-02 FOR BOLTS AND LINE CLAMPS. 3 DEC 2 8/7/14 SALAS DANNA ADCOCK 1 3/21/13 McCONNELL DANNA ADCOCK 0 11/8/12 HOFFMAN DANNA ADCOCK BY CK'D APPR. REVISED DEM DEP DEF X SINGLE-PHASE CONSTRUCTION - FUSED TAP 08.01-38 KHLC40N6F OR KHLC7933F TOP BRACKET BOLT 5" 3" #2 WP COPPER CU RCRISERN2CUF 6" 12" 3" BOTTOM BRACKET BOLT 4" 1ST PHASE POSITION IN S UL AT OR 36" 12 0" GU Y FUSE15CO100F IDES25PF 2ND PHASE POSITION 78 "G UY IN SU LA TO R 36" IN SU L AT O R 3RD PHASE POSITION 78 "G UY 72" 4" 4" 12 KV NOTES: 1. MIDDLE CUTOUT CAN BE PLACED ON SAME SIDE OF POLE AS OTHER CUTOUTS. 2. FOR FEEDER TAPS, THE CUTOUTS ARE OMITTED, BUT THE SPACING FOR THE TAP IS THE SAME. 3. SEE DWG. 03.06-02 FOR BOLTS AND LINE CLAMPS. 3 DEC 2 DEM DEP VERTICAL CONSTRUCTION - TANGENT 1 8/7/14 SALAS DANNA ADCOCK 0 11/8/12 HOFFMAN DANNA ADCOCK BY CK'D APPR. REVISED FUSED TAP CONSTRUCTION DEF X 08.01-39 TRADITIONAL NON-LOADBREAK SECTIONALIZER USER SETABLE NON-LOADBREAK SECTIONALIZER COLOR CODED BANDS * SEE QUICK REFERENCE MANUAL FOR TOP USER OPERATING INSTRUCTIONS. NO BAND = 2 COUNT GREEN BAND = 3 COUNT BOTTOM BROWN BAND = 100 AMP NO BAND = 200 AMP RESETTABLE SECTIONALIZER RESETTING TRADITIONAL SECTIONALIZERS CAP ELECTRONICS LOWER TRUNION INSERT THE OPENING OF AN ADJUSTABLE WRENCH INTO THE HOLE ON THE BACK OF THE TRUNION. ROTATE THE TRUNION WITH THE WRENCH UNTIL TRUNION DOOR IS COMPLETELY SHUT. SLOWLY, REMOVE THE WRENCH FROM THE TRUNION. THE TRUNION WILL SNAP OPEN IF IT IS NOT FULLY CLOSED. BILL OF MATERIALS CU ITEM NO. 1 2 3 4 5 6 MACRO UNIT - COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER SECT15E100S2F SECT15E100S3F SECT15E200S2F SECT15E200S3F SECT27E100S2F SECT15EABBF 1 1 1 1 1 1 300601 9220108582 9220108583 9220109650 9220086479 9220181861 QTY PER CU 1 1 1 1 1 1 DESCRIPTION SECTIONALIZER, SECTIONALIZER, SECTIONALIZER, SECTIONALIZER, SECTIONALIZER, SECTIONALIZER, 15KV, 15KV, 15KV, 15KV, 25KV, 15KV, NLBK, NLBK, NLBK, NLBK, NLBK, NLBK, 1-PH, 1-PH, 1-PH, 1-PH, 1-PH, 1-PH, 100A, 2-SHOT, NO CUTOUT 100A, 3-SHOT, NO CUTOUT 200A, 2-SHOT, NO CUTOUT 200A, 3-SHOT, NO CUTOUT 100A, 2-SHOT, NO CUTOUT USER SETABLE, NO CUTOUT NOTES: 1. SECTIONALIZERS WILL FIT IN A STANDARD NLB INTERCHANGEABLE CUTOUT. 2. SECTIONALIZERS HAVE NO FAULT CURRENT INTERRUPTING CAPABILITY. THEY RELY ON THE SOURCE SIDE BREAKER OR RECLOSER TO OPEN DURING THE FAULT. THE SECTIONALIZER OPENS WHILE THE BREAKER/ RECLOSER IS OPEN. THEY DO NOT RELY ON FAULT CURRENT FOR COORDINATION; THEREFORE THEY ARE USEFUL WHERE COORDINATION PROBLEMS EXIST. 3. SECTIONALIZER COUNTS WHEN LINE CURRENT DROPS BELOW 300 mA. 4. CONTACT YOUR SYSTEM ENGINEER PRIOR TO INSTALLATION ON MULTI-PHASE LOCATIONS. 5. ITEM 6 - SEE QUICK REFERENCE MANUAL FOR OPERATING INSTRUCTIONS. 3 2 ELECTRONIC RESETTABLE SECTIONALIZERS R 1 6/16/11 HOFFMAN 0 9/20/10 HOFFMAN GUINN ELKINS DWG. BY CK'D APPR. 08.04-02 REVISED BURLISON ELKINS RECLOSERS, SECTIONALIZERS, TRANSFERS GENERAL 1. USE THE SUPPLIED GROUNDING CONNECTOR ON THE OIL SECTIONALIZER TANK AND RECLOSER TANK TO GROUND THE UNIT TO THE ARRESTER DOWN LEAD. 2. A LOAD BREAK TOOL SHOULD BE USED TO OPEN DRY TYPE SECTIONALIZERS AND RECLOSER BYPASS SWITCHES. 3. FOR VERTICAL CONSTRUCTION THE MINIMUM TANK CLEARANCE BETWEEN SINGLE-PHASE RECLOSER TANKS AND ADJACENT RECLOSER BUSHINGS IS TO BE 13 INCHES. 4. FOR THREE-PHASE RECLOSERS, THE GROUND TRIP SHORTING SWITCH OPERATES AS FOLLOWS: A. SWITCH-UP - THE GROUND TRIP IS CUT OUT B. SWITCH DOWN - THE GROUND TRIP IS CUT IN 5. THE THREE-PHASE RECLOSER MAY BE REVERSED IN THE MOUNTING BRACKET TO ACCOMMODATE THE SOURCE TO LOAD DIRECTION OF FEED THROUGH THE RECLOSER. 3 2 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. RECLOSERS, SECTIONALIZERS, TRANSFERS AND THREE-PHASE RECLOSER LIGHTNING ARRESTER MOUNTING DETAIL R DWG. 08.05-00 SEQUENCE 2A2B 2A2C 2A2D 1A3B 1A3C 1A3D 1A2B 1A2C 1A2D SINGLE-PHASE RECLOSERS OPERATING SEQUENCE TWO FAST FOLLOWED BY TWO RETARDED TWO FAST FOLLOWED BY TWO EXTRA RETARDED TWO FAST FOLLOWED BY TWO STEEP RETARDED ONE FAST FOLLOWED BY THREE RETARDED ONE FAST FOLLOWED BY THREE EXTRA RETARDED ONE FAST FOLLOWED BY THREE STEEP RETARDED ONE FAST FOLLOWED BY TWO RETARDED ONE FAST FOLLOWED BY TWO EXTRA RETARDED ONE FAST FOLLOWED BY TWO STEEP RETARDED CURVE(S) A AND B A AND C A AND D A AND B A AND C A AND D A AND B A AND C A AND D TYPE - AMPS RATING, 2" MFG. SERIAL NUMBER, 2" OPERATING CURVES, 3" INCLUDED RECLOSERS: H, 4H, L, V4L AND E CATALOG NUMBER, 2" UP TO 10 DIGITS NON-PCB CERTIFICATION, 2" MAINTENANCE DATE, 1" SINGLE-PHASE RECLOSERS 1 - PHASE TRIP COIL SIZE: 100, 160, 185, 225, 280, 400, 400X, 560, 560X 2 - PHASE TRIP TIME DELAY CURVE: B, C, D OR E-CURVE 3 - PHASE TRIP OPERATING SEQUENCE: A. NUMBER OF OPERATIONS ON A-CURVE B. NUMBER OF OPERATIONS ON DELAYED B, C, D OR E-CURVE 4 - BUSHING CT RATIO: 100 (100:5) 200(200:5) 300(300:5) 400 (400:5) 500(500:5) 600(600:5) 5 - GROUND TRIP TIME DELAY CURVE: 2 3 6 - GROUND TRIP FAST OPEN OPERATIONS: 1 2 3 4 7 - GROUND TRIP SOLENOID CONNECTION: 1 (SERIES) 2 (PARALLEL) 8 - CATALOG NUMBER (UP TO 10 DIGITS) 9 - MANUFACTURER'S SERIAL NUMBER 10 - MAINTENANCE DATE 11 - NON-PCB CERTIFICATION (ON END WITH OPERATING HANDLE) 3A 1 3B 400-2A2D 3" CNCNCNCNCN 8 11 6 3" 9 XX-XX 4 5 10 7 INCLUDED RECLOSERS: VW AND WV THREE-PHASE HYDRAULIC RECLOSERS ALL HYDRAULICS - NOT VACUUM UNITS 1 2 3 4 5 - CATALOG NUMBER (UP TO 10 DIGITS) MANUFACTURER'S SERIAL NUMBER MANUFACTURER'S TYPE RECLOSER: VWE, VR3S AND OVR FULL-LOAD CURRENT RATING (560, 630, 800) MAINTENANCE DATE 2 NOTES: 5 1. STENCIL THE CATALOG NUMBER ON THE OUTSIDE, PADLOCK SIDE OF THE RECLOSER ELECTRONIC CONTROL CABINET. SNSNSNSN VR3S-560 CNCNCNCN 3 4 1 THREE-PHASE ELECTRONIC CONTROLLED RECLOSERS 1 2 3 4 - AMPERE RATING COUNTS TO OPEN OR SHOTS TO LOCKOUT MAINTENANCE DATE CATALOG NUMBER, 2" HANGER ON BACK SIDE OF SECTIONALIZER 1 NOTES: 1. SEE DWG. 08.04-02 FOR ELECTRONIC SECTIONALIZERS. 3 CNCN 2 4 HYDRAULIC SECTIONALIZERS 3 2 RECLOSER IDENTIFICATION 1 0 11/29/10 REVISED R GUINN GUINN HOYT DWG. BY CK'D APPR. 08.05-01 B B A A 12" C C DIMENSIONS TYPE 4H, L, V4L, E AND 4E RECLOSERS DIMENSIONS TYPE H RECLOSER RECLOSER TYPE DIMENSION (IN.) 4H L V4L E 4E H A 36 37 45 42 49 30 B 17 19 19 20 23 16 C 7 6 15 9 15 14 WEIGHT WITH OIL (LBS.) 114 159 205 169 205 85 OIL CAPACITY (GAL.) 5 7 9.5 8.2 9.5 4 NOTES: 1. THE DIMENSIONS, WEIGHTS AND CAPACITIES LISTED ABOVE ARE APPROXIMATE. 3 DEC 2 DEM DEP TYPICAL SINGLE-PHASE RECLOSER 1 11/17/15 LOOSIER BURLISON ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DIMENSIONS, WEIGHTS AND OIL CAPACITIES DEF X 08.05-02 CLOSED G N N O I N OS L VIEW OF LEVER CONTROL MECHANISM C RE O P E N RETURN TO "UP" POSITION AFTER USE SET LEVER IN THIS POSITION FOR NONRECLOSING NON-AUTOMATIC RECLOSING LEVER NOTES: 1. NON-AUTOMATIC RECLOSING LEVER FOR COOPER RECLOSERS PROVIDES ONE-SHOT LOCKOUT OF THE RECLOSER WHEN TRIPPED ELECTRICALLY. IT IS CONTROLLED BY AN ADDITIONAL LEVER UNDER THE OPERATING HANDLE HOOD WHICH, WHEN PULLED DOWN, ENGAGES THE LOCKOUT AND PLUNGER MECHANISMS, BYPASSING THE HYDRAULIC LOCKOUT IN SUCH A MANNER THAT WHEN THE SOLENOID PLUNGER IS PULLED DOWN, THE LOCKOUT MECHANISM IS TRIPPED. IN ORDER FOR THE RECLOSER TO RESUME NORMAL, FULL-AUTOMATIC OPERATION, THE LEVER IS MOVED BACK TO THE "UP" POSITION. THE LEVER OPERATES ON A TOGGLE SO THAT IT IS POSITIVELY IN THE NON-AUTOMATIC OR AUTOMATIC POSITION. 2. AFTER USE, THE NON-AUTOMATIC RECLOSING LEVER MUST BE RETURNED TO NORMAL "UP" POSITION TO PROVIDE AUTOMATIC RECLOSING TO CLOSE, PLACE HOTSTICK TIP AGAINST MANUAL OPERATING HANDLE AND PUSH UPWARD TO OPEN, INSERT HOTSTICK TIP INTO EYELET OF MANUAL OPERATING HANDLE AND PULL DOWNWARD. 3 2 COOPER RECLOSERS 1 0 7/31/14 REVISED GUINN GUINN ADCOCK BY CK'D APPR. OPERATING LEVERS DEC DEM DEP DEF X X X X 08.05-06 PLAN VIEW 5" LOAD SOURCE 6" 3 26" 4 2 1 54" SEE DWG. 08.05-15B 28" 6" 26" 54" 28" #2 SD BC 6" 26" ALL ENERGIZED PARTS SHOULD BE COVERED TO GUARD AGAINST DAMAGE CAUSED BY ANIMALS #2 SD BC 72" 46" FUSES STORED WITH BARRELS DOWN ON 3" STAPLE #2 SD BC #6 SD BC FRONT VIEW SIDE VIEW BILL OF MATERIALS MACRO UNIT - CU ITEM NO. 1 2 3 4 COMPATIBLE UNIT FUSE15CO100F SW153COSBDF KHLC40N6F RCRISERN2CUF QTY. REQ'D. 1 2 2 1 2 4 4 2 ITEM NUMBER 3 6 6 3 221112 9220210916 9220184790 9220218857 QTY PER CU 1 1 1 12 FT. DESCRIPTION CUTOUT, LB, 15KV, 100A, 16KA, 110KV BIL CUTOUT, BLADE, SLD CLAMP, HOT LINE, ALUMINUM, SMALL WIRE, COPPER, #2, SOLID, 600V, SD COPPER NOTES: 1. ISSUE RECLOSER SEPARATELY. RECLOSER WILL COME WITH ARRESTERS PRE-MOUNTED. *2. FOR ALL V4L RECLOSER INSTALLATIONS ON VERTICAL CONSTRUCTION, INCREASE THE PHASE SPACING BETWEEN THE PRIMARY CONDUCTORS FROM 54" TO 64" AND INCREASE THE 28" DIMENSIONS TO 38". 3. SEE DWG 08.05-15B FOR BRACKET DETAILS AND BILL OF MATERIALS. 4. FOR SINGLE-PHASE AND TWO-PHASE INSTALLATIONS, USE SPACING REQUIREMENTS FROM BOTTOM UNIT CLOSEST TO NEUTRAL TOWARDS THE TOP OF THE POLE. 5. EQUIPMENT CASE GROUND TO NEUTRAL TO BE #2 SD BC. 6. IF RECLOSERS ARE USED IN MAINLINE FEEDER (336 OR 795), USE 600 AMP RECLOSER BYPASS (SEE DWG. 08.10-10) INSTEAD OF CUTOUTS WITH SOLID BLADES. 7. DISCONNECT CONNECTIONS MAY BE MADE WITH SOLID CONNECTION IN LIEU OF HOT LINE CLAMP AND STIRRUP. 3 11/17/15 LOOSIER BURLISON ADCOCK 2 4/21/15 LOOSIER BURLISON ADCOCK 1 3/29/11 HOFFMAN BURLISON ELKINS 0 10/6/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION X 08.05-15A 18" 12" 12" TOP VIEW 8" 1 SIDE VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER - 1 BKTEQ1824FGF 1 9220201401 13264 13308 152107 QTY PER CU 1 2 2 2 DESCRIPTION BRACKET, FG, CUTOUT MTG BKT, 3 HOLE WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, 2-1/4", SQUARE, FLAT, 13/16", HOLE, GALV. BOLT, MACH, SQ. NUT, 5/8" X 12" NOTES: 1. SEE DWG 08.05-15A FOR RECLOSER INSTALLATION DETAILS. 2. USE ONE CU PER RECLOSER INSTALLED. 3 2 1 0 10/11/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. OIL CIRCUIT RECLOSER SINGLE-PHASE INSTALLATION BYPASS CUTOUT BRACKET R DWG. 08.05-15B 5" 4" 11" SEE NOTE 3 2 16" 60" (SEE NOTE 2) 3 1 60" 4 72" NOTES: 1. SEE DWG. 08.05-16B FOR BILL OF MATERIALS. 2. FOR ALL V4L RECLOSER INSTALLATIONS ON VERTICAL CONSTRUCTION, INCREASE THE PHASE SPACING BETWEEN THE PRIMARY CONDUCTORS FROM 60" TO 64". 3. RISER SIZE SHOULD MATCH PRIMARY CONDUCTOR SIZE. 5 11/17/15 LOOSIER BURLISON ADCOCK 4 8/27/15 LOOSIER BURLISON ADCOCK 3 4/21/15 LOOSIER BURLISON ADCOCK 0 9/28/11 BURLISON BURLISON ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION, FEEDER X 08.05-16A BILL OF MATERIALS CU MACRO UNIT ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156BYPF 1 2 3 2 KLC2H50ALF 2 4 6 3 KLC2H50AL90DF 2 4 6 4 RCRISER500ALF 2 4 6 - CATALOG NUMBER QTY 010928 0012277 013128 013264 013308 013407 152107 260123 010928 012277 PER CU 8 8 8 2 2 16 2 1 2 2 DESCRIPTION BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, 304, ALLOY, COARSE THRD. WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT SPRING, DOUBLE COIL, STEEL, FOR, 5/8", BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, ROUND, FLAT, STAINLESS, STEEL, 304, ALLOY, FOR, 1/2" BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 3-SLD BLADE DISC, 15KV, LBK, HOOKS, 600A, LEFT BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, 304, ALLOY, COARSE THRD. 013163 155326 10542504 010928 012277 013163 10542504 9220068102 202112 4 1 2 2 2 4 2 1 12 WASHER, FLAT, 1/2 IN, SILICON BRONZE, FLAT, ROUND LUG, COMPRESSIN, 2H-795AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, 304, ALLOY, COARSE THRD. WASHER, FLAT, 1/2 IN, SILICON BRONZE, FLAT, ROUND WASHER, ROUND, 1/2, SS, 1.375" OD LUG, 2-HOLE, TIN-PLATED, NEMA CABLE, XLP UG AL 500 NOTES: 1. ISSUE RECLOSER SEPARATELY. RECLOSER WILL COME WITH ARRESTERS PREMOUNTED. 2. SEE DWG. 08.05-16A FOR DESIGN SPECIFICATIONS. 3 DEC DEM DEP DEF RECLOSER ASSEMBLY, 2 X 1 0 5/28/14 REVISED LOOSIER DANNA ADCOCK BY CK'D APPR. VERTICAL CONSTRUCTION, FEEDER 08.05-16B 5" 6" 1 26" 2 54" 28" 3 6" 26" 4 SEE DWG. 08.05-15B 54" ALL ENERGIZED PARTS SHOULD BE COVERED TO GUARD AGAINST DAMAGE CAUSED BY ANIMALS 28" 6" 26" 72" #2 SD BC #2 SD BC 46" FUSES STORED WITH BARRELS DOWN ON 3" STAPLE #6 SD BC SIDE VIEW FRONT VIEW NOTES: 1. SEE DWG. 08.05-18B FOR PLAN VIEW, BILL OF MATERIALS AND NOTES. 3 DEC 2 11/17/15 LOOSIER BURLISON ADCOCK 1 4/21/15 LOOSIER BURLISON ADCOCK 0 12/6/13 SALAS DANNA ADCOCK BY CK'D APPR. REVISED DEM DEP DEF RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION SLACK SPAN TAP X 08.05-18A 5 SOURCE 8 6 7 PLAN VIEW LOAD BILL OF MATERIALS MACRO UNIT - CU ITEM NO. 1 2 3 4 5 6 7 8 QTY REQ'D COMPATIBLE UNIT FUSE15CO100F SW153COSBDF KHLC40N6F RCRISERN2CUF SCLMP10AAACF IDES25PF DECLMP10AAACF MIDSPANTAPF 1 2 3 1 1 1 1 1 2 4 6 2 2 2 2 2 ITEM NUMBER 3 6 9 3 3 3 3 3 0000221112 9220210916 9220184790 9220218857 0000090306 080577 0000100708 0000115428 QTY PER CU 1 1 1 12FT. 1 1 1 1 DESCRIPTION CUTOUT, LB, 15KV, 100A, 16KA,100KV BILL CUTOUT, BLADE, BLADE,SLD,NONLOADBREAK,300A,15 KV CLAMP, HOT LINE, ALUMINUM, SMALL WIRE, COPPER, #2 SOLID, COPPER, 600V, SD COPPER CLAMP, ANGLE, SUSPENSION,ANGLE,ALUMINUM,0.25-0.75" INSULATOR, POLYMER, 25KV, DE, SI, RATED 15KV CLAMP, DEADEND, DE,SO,6-4/0 ACSR,6-4/0 CU, 4-4/0 AL LINK, CHAIN,TWISTED,90,25M,3-3/8",LONG NOTES: 1. ISSUE RECLOSER SEPARATELY. RECLOSER WILL COME WITH ARRESTERS PRE-MOUNTED. 2. FOR ALL V4L RECLOSER INSTALLATIONS ON VERTICAL CONSTRUCTION, INCREASE THE PHASE SPACING BETWEEN THE PRIMARY CONDUCTORS FROM 54" TO 64" AND INCREASE THE 28" DIMENSIONS TO 38". 3. SEE DWG 08.05-15B FOR BRACKET DETAILS AND BILL OF MATERIALS. 4. SEE DWG 03.18-03 FOR ALTERNATE SLACK SPAN CONSTRUCTION DETAILS. 5. SEE DWG. 08.05-18A FOR DESIGN SPECIFICATIONS. 6. FOR SINGLE-PHASE AND TWO-PHASE INSTALLATIONS, USE SPACING REQUIREMENTS FROM BOTTOM UNIT CLOSEST TO NEUTRAL TOWARDS THE TOP OF THE POLE. 7. EQUIPMENT CASE GROUND TO NEUTRAL TO BE #2 SD BC. 8. IF RECLOSERS ARE USED IN MAIN LINE FEEDER (336 OR 795), USE 600 AMP RECLOSER BYPASS (SEE DWG. 08.10-10 ) INSTEAD OF CUTOUTS WITH SOLID BLADES. 9.DISCONNECT CONNECTIONS MAY BE MADE WITH SOLID CONNECTION IN LIEU OF HOT LINE CLAMP AND STIRRUP. 3 DEC DEM DEP DEF RECLOSER ASSEMBLY, VERTICAL CONSTRUCTION 2 1 11/17/15 LOOSIER BURLISON ADCOCK 0 12/6/13 SALAS DANNA ADCOCK BY CK'D APPR. REVISED SLACK SPAN TAP X 08.05-18B 9" 15 LOAD 6" SOURCE 5" 9" 5" 3 SOURCE 6" 9" 9 12" 1 2 BYPASS CUTOUTS 7 10 12" LOAD 20" 3" 15" 12" 30" 12" 30" 15" 3" 12" 8 3 11 16 SOURCE LOAD SOURCE LOAD 10' ARM 7 LOAD 12" 10 SOURCE 4" MIN. 2 6 14 5 SLEET HOOD SEE NOTE 9 10-1/4" 4 #2 CU TANK GROUND 17 12" #2 CU FRAME GROUND 12 #6 CU POLE GROUND BYPASS FUSE BARRELS 13 FRONT VIEW SIDE VIEW NOTES: 1. ALL SWITCHING SHALL BE DONE WITH TELESCOPIC STICK AS PER WORK STANDARDS. SOURCE AND LOAD CUTOUTS ARE TO HAVE SOLID BLADES. 2. HANG FUSE BARRELS FROM BY-PASS CUTOUTS ON A DRIVE HOOK OR LAG SCREW NEAR THE NEUTRAL. HANG BARRELS BY THE PULL RING SO WATER AND DEBRIS CANNOT COLLECT INSIDE BARREL. 3. ARRESTERS ARE TO BE CONNECTED TO BOTH SOURCE AND LOAD SIDE BUSHINGS AND INSTALLED ON THE RECLOSER BRACKET DIRECTLY BEHIND THE RECLOSER BUSHING AS SHOWN. 4. SOURCE BUSHING IS LOCATED OVER THE MANUAL (YELLOW) HANDLE. ROTATE HEAD TO HAVE THE HANDLE VISIBLE FROM NORMAL APPROACH (TYPICALLY ROAD SIDE). 5. BOND RECLOSERS TO THE RECLOSER MOUNTING BRACKET WITH #2 CU AND CONNECT TO SYSTEM NEUTRAL. 6. SINGLE-PHASE RECLOSERS HAVE DIFFERENT OPERATING CURVES: 2A2B, 2A2C, ETC. WHEN INSTALLING OR REPLACING A RECLOSER, BE SURE THE UNIT HAS THE CORRECT OPERATING CURVES AS WELL AS THE CORRECT AMPERE RATING TYPE. 7. SEE DWG. 08.05-114B FOR TABLES FOR RECLOSER TAP CONDUCTOR AND SWITCH SIZING AND BILL OF MATERIALS. 8. SEE SYSTEM PROTECTION FOR BY-PASS SWITCH DETAILS. 9. SEE DWG. 08.05-02 FOR RECLOSER HEIGHT MEASUREMENT. 3 2 1 12/16/15 LOOSIER BURLISON ADCOCK 0 11/17/15 BRUINS BURLISON ADCOCK BY CK'D APPR. REVISED OIL CIRCUIT RECLOSERS, THREE-PHASE INSTALLATION, DEC DEM DEP DEF HORIZONTAL CONSTRUCTION SINGLE-PHASE UNITS X X X X 08.05-114A BILL OF MATERIALS BUBBLE NUMBER COMPATIBLE UNIT CU QTY 1 ARMSDE120HFF 1 2 2 2 3 3 4 RCRISERN2CUF RCRISER10ALF RCRISER40ALF FUSE15CO100F SW153COSBDF RCL(VARIES) 6 6 6 3 6 3 5 BKTTFMRSMALF 1 WGEQBUSHSNAPF IHPTT35F 6 6 3 ISSTUDBOLT5812F 3 8 ARMS120FF 1 6 7 9 BKTCOLASTLXARMF 3 10 10 - 1 1 11 BKTCOLASTLXARMF 6 12 - 1 GOWE2F 1 GRODFRF 1 GAR1F 3 AREQOH10F IDES25PF DECLMP(VARIES) - 6 6 6 6 13 14 15 16 ITEM NUMBER 9220272389 152122 13346 13265 9220218857 54008800 202111 202112 9220210916 12912507 152122 13346 13265 152104 470114 9220284709 80217 72367 13264 9220201451 152107 13346 13264 70101 11213 9220284739 9220284740 70101 11213 14114 9220162221 15280 153111 160182 162205 160123 9220192319 60136 9220192319 220202 80577 - ITEM QTY/ CU 1 2 2 2 12 12 12 1 1 3 1 2 2 2 6 1 1 1 1 1 1 2 2 2 1 2 1 1 1 2 1 40 40 1 2 2 1 1 1 1 1 1 1 1 DESCRIPTION CROSSARM, DEADEND, HD, FIBERGLASS BOLT, HEX, 3/4 IN, 10"X12 STEEL, A307 WASHER SQUARE, RB, CRV, 3"X3" WASHER, LOCK, 3/4 IN DBL COIL CONDUCTOR, COPPER, WP #2 AWG CONDUCTOR, AAAC, 1/0, AAAC, 7-STR, 6201-T81 ALUMINUM ALLOY CABLE, XLP UG AL 4/0 CUTOUT, NON LOADBREAK, 15KV,100A CUTOUT, BLADE, BLADE,SLD,NONLOADBREAK,300A,15 KV RECLOSER TYPE L (VARIABLE AMP AND CURVE) BRACKET, MOUNTING, MTG,RACK,TF,SM THREE POS, 5-50KVA BOLT, SQUAREHEAD, 3/4 IN, 12 IN, S, A307, GLV, 10, UNC WASHER SQUARE, RB, CRV, 3"X3" WASHER, LOCK, 3/4 IN DBL COIL BOLT, MACHINE, 5/8 IN, 2 IN, ASTM A307, A, GALVANIZED, SQ GUARD, ANIMAL, 9 INCH HT GUARD, ANIMAL, 5 1/2 INCH HT INSULATOR, POST, LINE, 35KV ROUND BASE TIE TOP STUD, LINE POST, LP 5/8 INCH X 12 INCH WASHER, LOCK, 5/8 IN, STEEL, GLV, LK,5/8,COIL,DBL,GLV CROSSARM, TANGENT, 10 FT, FIBERGLASS, BRACELESS, TANGENT BOLT, MACHINE, 5/8 IN, 11 INX 12 IN, STEEL WASHER SQUARE, RB, CRV, 3"X3" WASHER, LOCK, 5/8 IN, STEEL, GLV, LK,5/8,COIL,DBL,GLV BRACKET, MOUNTING, 8 7/8 IN X 2 1/2 IN IN, GALVANIZED STEEL BOLT, CARRIAGE, 1/2 IN, 6 IN, STEEL, GLV TIE, COMPOSITE FOR #2 TO #2/0 TIE, COMPOSITE FOR #2/0 TO #4/0 BRACKET, MOUNTING, 8 7/8 IN X 2 1/2 IN IN, GALVANIZED STEEL BOLT, CARRIAGE, 1/2 IN, 6 IN, STEEL, GLV SCREW, LAG, 1/4 IN X 2 IN, STEEL, GLV, LAG,HX,1/4-INCH O.D. CONDUCTOR, COPPER, #2 SOLID, SOFT DRAWN, BARE STAPLE, DIAMOND POINT, GALV STL 2X5/8X3/16 CONNECTOR, COMPRESSION, COMP, AL CONNECTOR, GROUND, TF,GND,EYEBOLT CONNECTOR, VISE TYPE 2 CU CLAMP, GROUND, GRD,BRN,5/8 CAST BRONZE GROUND ROD CLAMP ROD, GROUND, 5/8 X 60 IN, COPPER CLAD, THREADLESS 5/8" X 5' COUPLING, ROD, 5/8 IN, COPPER PLATED STEEL, ROD,GRD,5/8 ROD, GROUND, 5/8 X 60 IN, COPPER CLAD, THREADLESS 5/8" X 5' ARRESTER, METAL OXIDE, 10KV,METOX DIST CLASS, METAL OXIDE INSULATOR, DEADEND, POLYMER,28KV,DEADEND,SILICONE DEADEND CLAMP (VARIES WITH WIRE SIZE) BLADES COME WITH SW253COSBDC NOTES: 1. SEE DWG. 08.05-114A FOR DESIGN SPECIFICATIONS AND NOTES. 3 2 1 12/16/15 LOOSIER BURLISON ADCOCK 0 11/17/15 BURLISON EANES ADCOCK BY CK'D APPR. REVISED OIL CIRCUIT RECLOSERS, THREE-PHASE INSTALLATION, HORIZONTAL CONSTRUCTION SINGLE-PHASE UNITS DEC DEM DEP DEF X 08.05-114B LOAD SOURCE 6" 6 7 10 48" 48" 5 4 11 48" PT 35" 9 8 76" L1 TERMINAL L1 L2 #6 SD BC 37" #2 SD BC 1 BLACK GREEN - GROUND 3 BLACK 4" SECONDARY ARRESTER 4" 12 SECONDARY ARRESTER CONNECTION #6 SD BC 4 HOLE SPADE ON RECLOSER 2 38" LOCKWASHER 1/2" SS BOLT NUT #6 BC BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG ROUND WASHER 48" MIN. ROUND BOLT #6 BC DETAIL "B" FRONT VIEW SIDE VIEW NOTES: 1. 2. 3. 4. 5. 6. 7. 8. SWITCHES TO BE ON ROAD SIDE. PT TO BE LOCATED ON SOURCE SIDE. RELOCATE ON RECLOSER FRAME IF NECESSARY. SIX ARRESTERS REQUIRED: 3 ON EACH SIDE. CONNECT TO TERMINALS OF RECLOSER WITH CONNECTOR UNDER WILDLIFE PROTECTORS. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. TOTAL WEIGHT OF THE RECLOSER AND FRAME IS 850 LBS. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FT-LBS. DO NOT EXCEED! SEE DWG. 08.06-08B FOR BILL OF MATERIALS. 4 12/19/14 BURLISON GUINN ADCOCK 3 5/28/14 GUINN GUINN ADCOCK 2 11/8/12 HOFFMAN DANNA ADCOCK 0 10/12/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER AND FRAME, THREE-PHASE, ABB WITH VERTICAL BYPASS SWITCH X 08.06-08A BILL OF MATERIALS MACRO UNIT - CU ITEM NO. COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER 9220090147 152107 013308 013264 013128 013407 010928 012277 9220069244 9220087550 9220100429 013264 013308 152107 260123 9220087868 9220091018 9220068094 220202 010928 012277 013163 155326 10542504 9220068102 202112 323422 434122 434142 220139 9220102212 9220102213 9220102214 1 RCOVR630E15V1F 1 2 3 RCCNTLPCDABBF RCOVRCAB40F 1 1 4 SW156BYPF 3 5 6 7 8 BKTFBGPIN15138F IPIN25PF TTIEF500COVALPF AREQOH10F 4 4 4 6 9 KLC2H50ALF 6 10 11 KLC2H50AL90DF RCRISER500ALF 6 6 12 CRIS1UGPVC225CF 2 13 14 15 16 AREQSC120F WGRCTERMGSF WGRCLSHPF WGRCPTTRF 1 3 3 3 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER RCOVR630E27V1F RCCNTLPCDABBNSF RCCNTLPCDRFF RCPCDLCMF - 1 1 1 1 1 - 9220087177 9220085219 9220087633 9220085231 9220087552 9220102215 9220087542 9220100256 9220085226 9220102547 9220127574 9220127570 9220127579 9220127587 9220127588 9220127589 9220127564 9220085231 9220087168 QTY PER CU 1 16 17 15 75 72 36 36 4 1 1 2 2 2 1 1 1 1 1 2 2 4 1 2 1 12 1 0.2 3 1 1 1 1 DESCRIPTION RECLOSER TYPE OVR 630 AMP ELEC. 15KV VRT MNTG W/1PT BOLT, MACHINE, SQ, NUT, 5/8" X 12" WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304 ALLOY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WIRE, TIE, #4 SD BC, SLD RECLOSER CONTROL PCD 2000 FOR ABB RECL RECLOSER CONTROL CABLE FOR ABB VR3 AND OVR, 40FT WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 3-SLD BLADE DISCONNECT, 15KV, LBK BRACKET, FIBERGLASS STAND-OFF, 1-3/8" THREAD INSULATOR, 25 KV POLYMER, 1-3/8" THREAD PLASTIC TIE WRAP FOR 2-7/8" F-NECK INSULATOR ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H 500 AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD LUG, 2-HOLE, TIN-PLATED, NEMA, 90 DEGREE CABLE, XLP UG AL 500 GUARD, PVC, CABLE, 2-1/4" X 10' BANDING, STAINLESS STEEL, 316, 3/4" WIDE, .030 TH BANDING, BUCKLE, SS, 3/4", FOR BANDING ARRESTER, LIGHTNING, SEC 120-240 3 WIRE GUARD, ANIMAL, TERMINAL GUARD, STRAIGHT GUARD, ANIMAL, L-SHAPED, GUARD GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER ADDITIONAL PARTS FOR REPLACEMENT MACRO UNIT - CU ITEM NO. 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 QTY PER CU 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DESCRIPTION RECLOSER, ABB OVR-630 AMP, 12KA, 27KV-HV EDGEMOUNT COASTAL RECLOSER, PCD,CONTROL,LV,MODULE,WITHOUT,SINGLE-PHASE,TRI RECLOSER, CONTROL, PCD 2000 COOPER RETROFIT TRANSFORMER, POTENTIAL, 15KV,7200V MODULE, LOOP CONTROL, RECLOSER, ABB, FOR PCD CONTROL. CABLE LOCKING SLEEVE - ABB RECL. CTRL CABLE CONNECTOR BATTERY, RECLOSER, PCD CNTRL, 48VDC (SET OF 4-12VDC) CABLE-PT, ABB RECLOSER, 8 FOOT, W/2-5-PRONG CONNECTORS ABB PCD SINGLE-PHASE TRIP CARD COM5 MODULE/CARD FOR ABB PCD CONTROL (SLOT-E) ABB PCD UPS CARD TYPE 3, 48VDC (SLOT-A) ABB PCD UPS CARD TYPE 2, 48VDC (SLOT-A) ABB PCD DIO-2B I/O CARD (SLOT-B) ABB PCD DIO-1 I/O CARD (SLOT-C) ABB PCE CPU-2 CARD (SLOT-D) ABB PCD COM-2A CARD (SLOT-E) ABB PCD PT/CT 600:1 CARD (SLOT-F) EXTERNAL PT FOR ABB OVR RECL, 13.8V, 110BIL, VOG-11, 60:1 COASTAL EXT. PT- ABB OVR RECL, 13.8 KV, 125 KV BIL, W/60:1 RATIO NOTES: 1. 2. 3. 4. 5. 6. GROUND RESISTANCE TO BE 15 OHMS OR LESS. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. TOTAL WEIGHT OF RECLOSER ASSEMBLY IS 850 LBS. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FT-LBS: DO NOT EXCEED! SEE DWG. 08.06-08A DESIGN SPECIFICATIONS. 4 12/19/14 BURLISON GUINN ADCOCK 3 11/14/12 HOFFMAN DANNA ADCOCK 2 3/28/12 HOFFMAN BURLISON ELKINS 0 11/9/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER ASSEMBLY, THREE-PHASE, ABB WITH VERTICAL BYPASS SWITCH X 08.06-08B 5" 36" 36" EXTRA CAUTION SHOULD BE TAKEN WHEN BOLTING CONNECTIONS OR TRAINING LEADS TO BUSHINGS. SEE NOTE 4 ON DWG. 08.06-08B. LOAD SOURCE 36" 6" 48" 48" 48" SEE DETAIL "A" SEE DETAIL "B" 35" 76" #6 SD BC 37" #2 SD BC CN 153109 CN 9220102212 4" 4" USE WILDLIFE GUARDS CN 9220102213 #6 SD BC 38" BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG 48" MIN. DETAIL "A" DETAIL "B" CN 9220102214 FRONT VIEW NOTES: SIDE VIEW 1. SEE DWG. 08.06-08B FOR BILL OF MATERIALS AND REPLACEMENT PARTS FOR RECLOSER INSTALLATION. 2. A 55' CLASS 3 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. 3. SEE DWG. 08.06-08A FOR MORE DETAILS ON RECLOSER INSTALLATION, INCLUDING SECONDARY AND PRIMARY ARRESTER CONNECTIONS. 3 2 DEC 12/19/14 BURLISON GUINN ADCOCK 1 11/8/12 HOFFMAN DANNA ADCOCK 0 10/12/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEM DEP ABB RECLOSER ON VERTICAL DOUBLE CIRCUIT W/ VERTICAL BYPASS SWITCH DEF X 08.06-10 5" USE WILDLIFE GUARDS SOURCE 6" LOAD 3 4 5 24" 48" DETAIL "A" 9 48" 2 (2) 9220252997 (4) 9220102213 24" 8 10 16 DETAIL "B" VIPER ST JUNCTION BOX PANEL; SEE NOTE 4 ON 08.06-11C 56" 7 SOURCE SEE DETAIL "A" 56" 17 SEE DETAIL "C" LOAD 108" L1 6 #2 CU TERMINAL L1 1 L2 BLACK 12 SEE DETAIL "B" GREEN - GROUND BLACK NEUTRAL SECONDARY ARRESTER 14 15 11 SECONDARY ARRESTER CONNECTION IN CONTROL BOX #6 SD BC 4 HOLE SPADE ON RECLOSER LOCKWASHER 1/2" SS BOLT 13 38" NUT #6 WP ROUND WASHER #6 WP 48" MIN. BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG ROUND BOLT DETAIL "C" FRONT VIEW SIDE VIEW NOTES: 1. SEE DWG. 08.06-11C FOR BILL OF MATERIALS AND NOTES. 2. BRACKET IS REVERSIBLE AND CAN BE INSTALLED ON EITHER SIDE OF POLE TO SUIT FIELD CONDITIONS. 3. IN COASTAL AREAS, USE DWG. 08.06-12A FOR 25KV CONSTRUCTION. 6 8/10/15 LOOSIER BURLISON ADCOCK 5 7/1/15 LOOSIER BURLISON ADCOCK 4 2/17/14 McCONNELL DANNA ADCOCK 0 10/12/12 HOFFMAN BURLISON ADCOCK BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH X 08.06-11A 16 59.62" SOURCE SIDE LOAD SIDE 6 17 19 55.76" 44.75" 6 16.5" 27.66" 47.7" ATTACH GROUND STIRRUP TO FRAME 1 PT JUNCTION BOX 29.74" LOWER SUPPORTS SHIPPED UNATTACHED RIGHT VIEW BACK VIEW (ANIMAL GUARD NOT SHOWN FOR CLARITY) #6 CU WP SHIPPED WITH UNIT ALUMINUM POLE MOUNTING FRAME MODULE CABLE ACCESS IN THE J-BOX INTERNAL CURRENT TRANSFORMER #6 CU WP SEE DETAIL C ON DWG. 08.06-11A JUNCTION BOX RECLOSER CONTROL CABLE AND HARDWARE 2.13" 20" 1.27" 3.02" SPACING AVAILABLE FOR 3 ADDITIONAL PTS IF NECESSARY 52.06" LEFT VIEW NOTES: (ANIMAL GUARD NOT SHOWN FOR CLARITY) 1. SEE DWG. 08.06-11A FOR DESIGN SPECIFICATIONS. 2. SEE DWG. 08.06-11C FOR BILL OF MATERIALS AND NOTES. 3. BRACKET IS REVERSIBLE. DEPENDING ON HOW UNIT IS INSTALLED IN FIELD, DIAGRAMS ABOVE MAY BE REVERSED. 3 7/1/15 LOOSIER BURLISON ADCOCK 2 7/21/14 LOOSIER DANNA ADCOCK 1 2/17/14 McCONNELL DANNA ADCOCK 0 6/7/13 McCONNELL DANNA ADCOCK BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH X 08.06-11B BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 COMPATIBLE UNIT RCVST800E27V1F QTY REQ'D ITEM NUMBER 1 9220244274 152107 013308 013264 013128 013407 010928 012277 9220069244 QTY PER CU 1 16 17 15 75 72 36 36 4 8 8 8 2 2 16 2 1 2 2 2 1 1 1 1 2 2 4 1 2 2 2 SW156BYPF 3 3 BKTFBGPIN15138F 4 4 5 6 IPIN25PF TTIEF500COVALPF AREQOH10F 4 4 - 7 KLC2H50ALF 5 8 KLC2H50AL90DF 7 9 KLC2H79ALF 6 10 RCRISER500ALF 6 11 CRIS1UGPVC225WF 2 12 13 RCVIPCAB40F RCCNTL651GWF 1 1 010928 0012277 013128 013264 013308 013407 152107 260123 013264 013346 152107 9220087868 9220091018 9220068094 220202 010928 012277 013163 155326 10542504 010928 012277 013163 10542504 9220068102 010928 012277 013163 10542504 155331 202112 014111 323422 9220244739 9220244823 14 - - 9220267667 1 15 16 17 18 19 WGRCSLDSVF WGRCLSHPF WGRCPTTRF - 2 4 3 - PRECHARGE 9220252997 9220102213 9220102214 9220085231 1 1 1 3 - 2 4 2 1 2 2 4 2 1 12 15 1 1 1 DESCRIPTION RECLOSER TYPE VST 800 AMP ELEC. 27KV VRT MNTG BOLT, MACHINE, SQ, NUT, 5/8" X 12" WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304 ALLOY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WIRE, TIE, #4 SD BC, SLD BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING, DOUBLE COIL, F WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, ROUND, FLAT, STAINLESS, STEEL, 304, ALLOY, FOR, 1/2" BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 3-SLD BLADE DISC, 15KV, LBK, HOOKS, 600A, LEFT WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING, DOUBLE COIL, F WASHER,3", SQUARE, CURVED, 13/16", HOLE BOLT, MACH, SQ, NUT, 5/8" X 12" BRACKET, FIBERGLASS STAND-OFF, 1-3/8" THREAD INSULATOR, 25 KV POLYMER, 1-3/8" THREAD PLASTIC TIE WRAP FOR 2-7/8" F-NECK INSULATOR ARRESTER (INCLUDED FROM MANUFACTURER) BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H 500 AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, FLAT, ROUND, SILICON, BRONZE, FOR, 1/2", BOLT WASHER, ROUND, 1/2, SS, 1.375" OD LUG, 2-HOLE, TIN-PLATED, NEMA BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, FLAT, ROUND, SILICON, BRONZE, FOR, 1/2", BOLT WASHER, ROUND, 1/2, SS, 1.375" OD LUG, COMPRESSION, 2H-795AL CABLE, XLP UG AL 500 SCREW, LAG, HX, 1/4" X 2", STEEL, GALV. GUARD, PVC, CABLE, 2-1/4" X 10" VIPER ST CONTROL CABLE SEL 651 CONTROL CONTROL CABLE, 40' ARMORED 8 PIN FOR PT (INCLUDED FROM MANUFACTURER) 1" CONDUIT, FLEX, AND FITTING GUARD, ANIMAL, SOLID COVER, STRAIGHT, VERTICAL GUARD, ANIMAL, L-SHAPED GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER TRANF, POTENTIAL (INCLUDED FROM MANUFACTURER) NOTES: 1. SEE DWG. 08.06-11A FOR DESIGN SPECIFICATIONS. 2. GROUND RESISTANCE TO BE 15 OHMS OR LESS. 3. CONNECT ENDS OF POWER AND CONTROL CABLES WITH PROTECTIVE ARMORED FLEX TO CONTROL. 4. WHEN INSTALLING UNIT, OPEN JUNCTION BOX PANEL BY REMOVING SCREWS, RECORD 3 PT CORRECTION FACTORS LISTED AND PLACE ON INSIDE DOOR OF CONTROL. CLOSE JUNCTION BOX PANEL. 5. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. IF JOINT USE ON POLE, CLEARANCES MAY REQUIRE 50' POLE. 6. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. 7. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FT-LBS: DO NOT EXCEED! 8. PT'S TO BE LOCATED ON SOURCE SIDE. POWER SOURCE FOR PT'S FROM UNIT 1. 9. SIX ARRESTERS REQUIRED: 3 ON EACH SIDE. CONNECT TO TERMINALS OF RECLOSER AS SHOWN ON DETAIL C ON DWG. 08.06-11A. 10. USE #6 CU WP FOR ARRESTER SECONDARY CONNECTIONS. 11. TOTAL WEIGHT OF THE RECLOSER AND FRAME IS 750 LBS DOES NOT INCLUDE PT'S OR LA'S. 12. NEUTRAL MAY BE DOUBLE DEADENDED OR STRAIGHT THROUGH ON SPOOL AS NEEDED. 13. ARRESTORS, PT'S and 8 PIN PT CONTROL CABLE COME WITH RECLOSER FROM MANUFACTURER. 4 7/1/15 LOOSIER BURLISON ADCOCK 3 10/17/14 LOOSIER DANNA ADCOCK 2 5/2/14 LOOSIER DANNA ADCOCK 0 6/7/13 DANNA ADCOCK CK'D APPR. REVISED BY DEC DEM DEP DEF RECLOSER ASSEMBLY, THREE-PHASE, VIPER ST WITH VERTICAL BYPASS SWITCH X 08.06-11C 5" USE WILDLIFE GUARDS SOURCE 6" LOAD 3 4 5 24" 48" DETAIL "A" 9 48" 2 (2) 9220252997 (4) 9220102213 24" 8 10 16 DETAIL "B" VIPER ST JUNCTION BOX PANEL; SEE NOTE 4 ON 08.06-12C 56" 7 SOURCE SEE DETAIL "A" 56" 17 SEE DETAIL "C" LOAD 108" L1 6 #2 CU TERMINAL L1 1 L2 BLACK 12 SEE DETAIL "B" GREEN - GROUND BLACK NEUTRAL SECONDARY ARRESTER 14 15 11 SECONDARY ARRESTER CONNECTION IN CONTROL BOX #6 SD BC 4 HOLE SPADE ON RECLOSER LOCKWASHER 1/2" SS BOLT 13 38" NUT #6 WP ROUND WASHER #6 WP 48" MIN. BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG ROUND BOLT DETAIL "C" FRONT VIEW SIDE VIEW NOTES: 1. SEE DWG. 08.06-12C FOR BILL OF MATERIALS AND NOTES. 2. BRACKET IS NOT REVERSIBLE. WILL NEED TO MOUNT UNIT ROAD SIDE OR FIELD SIDE DEPENDING ON DIRECTION OF SOURCE. 3 8/10/15 LOOSIER BURLISON ADCOCK 2 7/17/15 LOOSIER BURLISON ADCOCK 1 11/6/13 SALAS DANNA ADCOCK 0 10/7/13 SALAS DANNA ADCOCK BY CK'D APPR. REVISED RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH - 25KV CONSTRUCTION - DEC DEM DEP DEF X 08.06-12A 16 59.62" SOURCE SIDE LOAD SIDE 6 17 19 55.76" 44.75" 6 16.5" 27.66" 47.7" ATTACH GROUND STIRRUP TO FRAME 1 PT JUNCTION BOX 29.74" LOWER SUPPORTS SHIPPED UNATTACHED RIGHT VIEW BACK VIEW (ANIMAL GUARD NOT SHOWN FOR CLARITY) #6 CU WP SHIPPED WITH UNIT ALUMINUM POLE MOUNTING FRAME MODULE CABLE ACCESS IN THE J-BOX INTERNAL CURRENT TRANSFORMER #6 CU WP SEE DETAIL C ON DWG. 08.06-12A JUNCTION BOX RECLOSER CONTROL CABLE AND HARDWARE 2.13" 20" 1.27" 3.02" SPACING AVAILABLE FOR 3 ADDITIONAL PTS IF NECESSARY 52.06" LEFT VIEW (ANIMAL GUARD NOT SHOWN FOR CLARITY) NOTES: 1. SEE DWG. 08.06-12A FOR DESIGN SPECIFICATIONS. 2. SEE DWG. 08.06-12C FOR BILL OF MATERIALS AND NOTES. 3 2 7/17/15 LOOSIER 1 7/21/14 LOOSIER DANNA ADCOCK 0 10/7/13 SALAS DANNA ADCOCK BY CK'D APPR. REVISED BURLISON ADCOCK RECLOSER AND FRAME, THREE-PHASE, VIPER ST, WITH VERTICAL BYPASS SWITCH - 25KV CONSTRUCTION - DEC DEM DEP DEF X 08.06-12B BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D ITEM NUMBER 9220244274 152107 013308 013264 1 RCVST800E27V1F 1 2 SW256BYPF 3 3 BKTFBGPIN15138F 4 4 5 6 IPIN25PF TTIEF500COVALPF AREQOH18F 4 4 6 7 KLC2H50ALF 5 8 KLC2H50AL90DF 7 9 KLC2H79ALF 6 10 RCRISER500ALF 6 11 CRIS1UGPVC225CF 2 12 13 14 15 16 17 18 19 RCVIPCAB40F RCCNTL651GWF WGRCSLDSVF WGRCLSHPF WGRCPTTRF - 1 1 40 2 4 3 - - QTY PER CU 1 16 17 15 013264 013346 152107 9220087868 9220091018 9220068094 220207 010928 75 72 36 36 4 8 8 8 2 2 16 2 1 2 2 2 1 1 1 1 2 012277 013163 155326 10542504 010928 012277 013163 10542504 9220068102 010928 012277 013163 10542504 155331 202112 323422 434122 434142 9220244739 9220244823 192324 PRECHARGE 9220252997 9220102213 9220102214 0020800983 2 4 1 2 2 2 4 2 1 2 2 4 2 1 12 1 0.2 3 1 1 1 1 1 1 3 013128 013407 010928 012277 9220069244 010928 0012277 013128 013264 013308 013407 152107 260552 DESCRIPTION RECLOSER TYPE VST 800 AMP ELEC. 27KV VRT MNTG BOLT, MACHINE, SQ, NUT, 5/8" X 12" WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304 ALLOY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WIRE, TIE, #4 SD BC, SLD BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING, DOUBLE COIL, F WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, ROUND, FLAT, STAINLESS, STEEL, 304, ALLOY, FOR, 1/2" BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 3-SLD BLADE DISC, 25KV, LBK HOOKS, 600A, LEFT OPENING WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING, DOUBLE COIL, F WASHER,3", SQUARE, CURVED, 13/16", HOLE BOLT, MACH, SQ, NUT, 5/8" X 12" BRACKET, FIBERGLASS STAND-OFF, 1-3/8" THREAD INSULATOR, 25 KV POLYMER, 1-3/8" THREAD PLASTIC TIE WRAP FOR 2-7/8" F-NECK INSULATOR ARRESTER, LIGHTNING, 18KV HD MOV W/SILICONE RUBBER POLY BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H 500 AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, FLAT, ROUND, SILICON, BRONZE, FOR, 1/2", BOLT WASHER, ROUND, 1/2, SS, 1.375" OD LUG, 2-HOLE, TIN-PLATED, NEMA BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, FLAT, ROUND, SILICON, BRONZE, FOR, 1/2", BOLT WASHER, ROUND, 1/2, SS, 1.375" OD LUG, COMPRESSION, 2H-795AL CABLE, XLP UG AL 500 GUARD, PVC, CABLE, 2-1/4" X 10' BANDING, STAINLESS STEEL, 316, 3/4" WIDE, .030 TH BANDING, BUCKLE, SS, 3/4", FOR BANDING VIPER ST CONTROL CABLE SEL 651 CONTROL CABLE, CONTROL, #10, 4 WIRE 1" CONDUIT, FLEX, AND FITTING GUARD, ANIMAL, SOLID COVER, STRAIGHT, VERTICAL GUARD, ANIMAL, L-SHAPED GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER TRANF, POTENTIAL, 25KV, 14400V NOTES: 1. SEE DWG. 08.06-12A FOR DESIGN SPECIFICATIONS. 2. GROUND RESISTANCE TO BE 15 OHMS OR LESS. 3. CONNECT ENDS OF POWER AND CONTROL CABLES WITH PROTECTIVE ARMORED FLEX TO CONTROL. 4. WHEN INSTALLING UNIT, OPEN JUNCTION BOX PANEL BY REMOVING SCREWS, RECORD 3 PT CORRECTION FACTORS LISTED AND PLACE ON INSIDE DOOR OF CONTROL. CLOSE JUNCTION BOX PANEL. 5. A 45' CLASS 4 POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. IF JOINT USE ON POLE, CLEARANCES MAY REQUIRE 50' POLE. 6. ISSUE TAPS TO SWITCHES SEPARATELY (WIRE, CONNECTORS, AND LUGS). BOLTS WILL BE ON SWITCH. 7. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FT-LBS: DO NOT EXCEED! 8. PT'S TO BE LOCATED ON SOURCE SIDE. POWER SOURCE FOR PT'S FROM UNIT 1. 9. SIX ARRESTERS REQUIRED: 3 ON EACH SIDE. CONNECT TO TERMINALS OF RECLOSER AS SHOWN ON DETAIL C ON DWG. 08.06-12A. 10. USE #6 CU WP FOR ARRESTER SECONDARY CONNECTIONS. 11. TOTAL WEIGHT OF THE RECLOSER AND FRAME IS 750 LBS DOES NOT INCLUDE PT'S OR LA'S. 12. NEUTRAL MAY BE DOUBLE DEADENDED OR STRAIGHT THROUGH ON SPOOL AS NEEDED. 13. RECLOSER COMES WITH 10KV ARRESTERS AND 7200 PT'S, REPLACE WITH 18KV ARRESTERS AND 14400 PT'S AS SHOWN IN THE BILL OF MATERIALS. 3 10/26/15 LOOSIER BURLISON ADCOCK 2 7/17/15 LOOSIER BURLISON ADCOCK 1 2/10/14 McCONNELL DANNA ADCOCK 0 10/7/13 SALAS DANNA ADCOCK BY CK'D APPR. REVISED RECLOSER ASSEMBLY, THREE-PHASE, VIPER ST WITH VERTICAL BYPASS SWITCH - 25KV CONSTRUCTION - DEC DEM DEP DEF X 08.06-12C SOURCE LOAD USE WILDLIFE GUARDS 5" 24" 3 4 5 48" 48" 24" 4" MIN. (TYP.) DETAIL "A" (2) 9220252997 (4) 9220102213 24" 48" 48" 24" 8 9 10 DETAIL "B" VIPER ST JUNCTION BOX PANEL; SEE NOTE 2 ON DWG. 08.06-13B 14 60" 7 4 HOLE SPADE ON RECLOSER 14" LOCKWASHER 1/2" SS 2 6 13 SEE DETAIL "C" 72" NUT #6 WP ROUND WASHER #6 WP ROUND BOLT 20 21 11 22 23 24 DETAIL "C" SEE DETAIL 'A' 27-3/4" 12 SEE NOTE 3 4" MIN. 6" 17 #2 SD BC TANK GROUND TO SYSTEM NEUTRAL 1 16 15 #6 SD BC SEE NOTE 4 18 L1 TERMINAL L1 L2 48" MIN. BLACK GREEN - GROUND BLACK SIDE VIEW (TANGENT PHASE OMITTED FOR CLARITY) SECONDARY ARRESTER SECONDARY ARRESTER CONNECTION IN CONTROL BOX FRONT VIEW 19 NOTES: 1. 2. 3. 4. SEE DWG. 08.06-13B FOR BILL OF MATERIALS AND NOTES. LEADS TO RECLOSER MUST BE A MINIMUM OF 14 INCHES CLEARANCE FROM THROUGH CIRCUIT. USE COLA CROSSARM BRACKET FOR OUTER TWO SOURCE SIDE ARRESTERS. THIS WILL SHORTEN JUMPER LENGTH. MOUNT PT JUNCTION BOX (INCLUDED WITH RECLOSER UNIT) ON PT BRACKET. WHOLE PT ASSEMBLY CAN BE BUILT ON GROUND PRIOR TO INSTALLATION. 3 DEC 2 8/10/15 LOOSIER BURLISON ADCOCK 1 4/10/15 LOOSIER BURLISON ADCOCK 0 2/13/15 LOOSIER GUINN ADCOCK BY CK'D APPR. REVISED DEM DEP DEF X DOUBLE CIRCUIT, THREE-PHASE, VIPER ST 08.06-13A BILL OF MATERIALS MACRO UNIT BUBBLE NUMBER COMPATIBLE UNIT CU QTY ITEM NUMBER 1 RCVST800E27HF 1 2 SW256RECBYPF 1 3 BKTFBGPIN15138F 6 4 5 IPIN25PF TTIEF500COVALPF 6 6 6 KLC2H50ALF 6 7 KLC4H79ALF 6 8 IHPTT15F 6 9 BKTFPIS30F 6 10 11 STIE795ALF AREQOH10F 6 6 12 BKTCOLASTLXARMF 2 13 14 15 16 RCRISER500ALF JUMP795ALF RCVIPCAB40F 6 12 1 17 CRIS1UGPVC225WF 2 18 19 20 RCCNTL651GWF AREQSC120F RCPTREC15F 1 1 3 21 BKT3PTRCTRISTLF 1 22 23 24 WGRCSLDSVF WGRCLSHPF WGRCPTTRF 3 3 3 9220248295 152107 13308 13264 9220248288 13264 13346 152107 9220087868 9220091018 9220068094 10928 12277 13163 155326 10542504 10928 12277 13163 10542504 155464 80212 13264 13346 70431 72361 152107 121434 220202 11213 70101 202112 9220218861 9220267667 9220244739 323422 14111 9220244823 220139 9220085231 9220224674 152107 9220132411 13264 9220252997 9220102213 9220102214 - ITEM QTY/ CU 1 2 2 2 1 2 2 2 1 1 1 2 2 4 1 2 2 2 4 2 1 1 2 2 1 1 2 1 1 2 1 12 8 1 1 15 1 1 1 1 2 2 2 1 1 1 DESCRIPTION RECLOSER, ELECTRONIC, G&W VIPER-ST, HORIZ MOUNT, 27 KV, 800 BOLT, MACHINE, SQ, NUT, 5/8"X12" WASHER, SQUARE, 2-1/4",SQUARE,FLAT,13/16",HOLE,GALV. WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING,DOUBLE COIL SWITCH, RECLOSER BY-PASS, THREE-PHASE HORIZONTAL WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING,DOUBLE COIL WASHER, 3",SQUARE, CURVED, 13/16" HOLE BOLT, MACHINE, SQ, NUT, 5/8"X12" BRACKET, STANDOFF, FIBERGLASS STAND-OFF, 1-3/8" THREAD INSULATOR, 25 KV POLYMER, 1 3/8" THREAD TIE, PLASTIC, 2-7/8",F-NECK,INSULATOR BOLT, MACHINE, 1/2 IN X 2 IN, STAINLESS STEEL, HEX HEAD NUT, HEX, 1/2 IN, STAINLESS STEEL WASHER, FLAT, 1/2 IN, SILICON BRONZE, ROUND LUG, COMPRESSION, 2H 500 AL WASHER, ROUND, 1/2", SS,1.375" OD BOLT, MACHINE, 1/2 IN X 2 IN, STAINLESS STEEL, HEX HEAD NUT, HEX, 1/2 IN, STAINLESS STEEL WASHER, FLAT, 1/2 IN, SILICON BRONZE, ROUND WASHER, ROUND, 1/2", SS,1.375" OD LUG, COMPRESSION, 4HOLE,795,AAC INSULATOR, POST, TIE, TOP, 25KV WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING,DOUBLE COIL WASHER, 3",SQUARE, CURVED, 13/16" HOLE BRACKET, STANDOFF, 30 IN, FIBERGLASS STUD, LINE POST, 5/8"X1-3/4" BOLT, MACHINE, SQ, NUT, 5/8"X12" TIE, E-Z, SIDE, F-NECK, 795,AAC ARRESTER, LIGHTNING, 10KV HD MOV W/SI RUBBER POLY HOUSING BOLT, CARRIAGE, 3/8 IN, 6 IN, CARBON STEEL BRACKET, ARRESTOR, LIGHTNING AND CUTOUT TYPE A CABLE, XLP UG AL 500 CONDUCTOR, ALUMINUM, AAC PT CONTROL CABLE (INCLUDED FROM MANUFACTURER) VIPER ST CONTROL CABLE GUARD, PVC, CABLE, 2-1/4" X 1-' SCREW, LAG, HX, 1/4' X 2', GALV SEL 651 CONTROL ARRESTER, LIGHTNING, SEC 120-240 3 WIRE TRANSFORMER, POTENTIAL, 15KV, 7200V BRACKET, MOUNTING, 42 IN, GALVANIZED STEEL, 3 PT MOUNTING BOLT, MACHINE, SQ, NUT, 5/8"X12" WASHER, SQUARE, 5/8 INCH SS, 2-1/4 INCH X 2-1/4 INCH WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING,DOUBLE COIL GUARD, ANIMAL, SOLID COVER, STRAIGHT, VERTICAL GUARD, ANIMAL, L-SHAPED,GUARD GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER NOTES: 1. SEE DWG. 08.06-13A FOR DESIGN SPECIFICATIONS. 2. WHEN INSTALLING UNIT, OPEN JUNCTION BOX PANEL BY REMOVING SCREWS, RECORD 3 PT CORRECTION FACTORS LISTED AND PLACE ON INSIDE DOOR OF CONTROL. CLOSE JUNCTION BOX PANEL. 3. MINIMUM 55' POLE REQUIRED. WHEN DESIGNING, CONSIDER VERTICAL TENSION ON ADJACENT POLES. 4. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED TO 40 FT-LBS: DO NOT EXCEED! 5. PT'S TO BE LOCATED ON SOURCE SIDE. POWER SOURCE FOR PT'S FROM UNIT 1. 6. NEUTRAL MAY BE DOUBLE DEADENDED OR STRAIGHT THROUGH ON SPOOL AS NEEDED. 3 DEC DEM DEP DEF 2 1 4/10/15 LOOSIER BURLISON ADCOCK 0 2/13/15 LOOSIER GUINN ADCOCK BY CK'D APPR. REVISED X DOUBLE CIRCUIT, THREE-PHASE, VIPER ST 08.06-13B 5'-0" MAX. SOURCE LOAD 4" 2 6 14" 5 7 SEE DETAIL "A" 72" CL BOLT HOLE SEE NOTE 2 17 13 14 15 16 3 27-3/4" 4 4" MIN. 6" SEE NOTE 3 SEE NOTE 4 #2 SD BC TANK GROUND TO SYSTEM NEUTRAL 1 10 12 8 #6 SD BC #6 SD BC POLE GROUND SIDE VIEW 11 L1 TERMINAL L1 4 HOLE SPADE ON RECLOSER L2 BLACK GREEN - GROUND LOCKWASHER 1/2" SS BOLT ROUND WASHER SECONDARY ARRESTER 9 38" NUT #6 WP BLACK MOUNT CONTROL ON OPPOSITE SIDE OF POLE FROM RECLOSER ROUND BOLT #6 WP SECONDARY ARRESTER CONNECTION IN CONTROL BOX BOLT ON TAMPER GUARDS FOR CONTROL CABLE PLUG AND POWER CABLE 5'-0" DETAIL "A" NOTES: 1. SEE DWG. 08.06-14B FOR BILL OF MATERIALS AND NOTES. FRONT VIEW 2. POSITION JUMPERS TO ENSURE MINIMUM OF 10" CLEARANCE BETWEEN THEM. 3. MOUNT PT JUNCTION BOX (INCLUDED WITH RECLOSER UNIT) ON PT BRACKET. WHOLE PT ASSEMBLY CAN BE BUILT ON GROUND PRIOR TO INSTALLATION. 4. USE COLA CROSSARM BRACKET FOR OUTER TWO SOURCE SIDE ARRESTERS. THIS WILL SHORTEN JUMPER LENGTH. 3 DEC DEM DEP DEF 2 1 4/10/15 LOOSIER BURLISON ADCOCK 0 3/31/15 LOOSIER BURLISON ADCOCK BY CK'D APPR. REVISED X VIPER RECLOSER HORIZONTAL CONSTRUCTION 08.06-14A BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER RCVST800E27HF 1 2 SW256RECBYPF 1 3 AREQOH10F 6 4 BKTCOLASTLXARMF 2 5 KLC2H50ALF 6 6 KLC4H79ALF 6 7 RCRISER500ALF 6 8 CRIS1UGPVC225WF 2 9 10 11 12 13 14 15 AREQSC120F RCVIPCAB40F RCCNTL651GWF WGRCSLDSVF WGRCLSHPF WGRCPTTRF 1 1 1 3 3 3 16 BKT3PTRCTRISTLF 1 17 RCPTREC15F 3 9220248295 013264 013308 152107 9220248288 220202 011213 070101 010928 012277 013163 155326 10542504 010928 012277 013163 10542504 155464 202112 323422 014111 220139 9220244739 9220244823 9220267667 9220252997 9220102213 9220102214 9220224674 152107 9220132411 013264 9220085231 - QTY PER CU 1 2 2 2 1 1 2 1 2 2 4 1 2 2 2 4 2 1 12 1 15 1 1 1 1 1 1 1 2 2 2 1 DESCRIPTION RECLOSER, ELECTRONIC, G&W VIPER-ST, HORIZ MOUNT, 27 KV, 800 A WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, SQ, NUT, 5/8" X 12" SWITCH, RECLOSER, RECLOSER BY-PASS, THREE-PHASE HORIZONTAL ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY BOLT, CARRIAGE, 3/8 IN, 6 IN, CARBON STEEL BRACKET, ARRESTOR, LIGHTNING AND CUTOUT TYPE A BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H 500 AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2" X 2" NUT, STAINLESS STEEL, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT WASHER, ROUND, 1/2", SS, BRONZE, FOR 1/2" BOLT LUG, COMP. 4H, 795 AL CABLE, XLP UG AL 500 GUARD, PVC, CABLE, 2-1/4" X 10' SCREW, LAG, HX, 1/4" X 2", GALV. ARRESTER, LIGHTNING, SEC 120-240 3 WIRE VIPER ST CONTROL CABLE SEL 651 CONTROL PT CONTROL CABLE (INCLUDED FROM MANUFACTURER) WILDLIFE GUARD RECL SOLID STRAIGHT VERTICAL COVER WILDLIFE GUARD RECL L-SHAPED COVER GUARD, ANIMAL, PT OR VOLTAGE TRANSFORMER BRACKET, MOUNTING, 42 IN, GALVANIZED STEEL, 3 PT MOUNTING BOLT, MACHINE, 5/8", 11" X 12", STEEL, ANSI C135.1., M WASHER, SQUARE, 2-1/4 X 2-1/4 X 3/16, GALV WASHER, LOCK, 5/8", STEEL, GLV, LK, 5/8, COIL, DBL TRANSFORMER, POTENTIAL, 15KV, 7200V NOTES: 1. SEE DWG. 08.06-14A FOR RECLOSER DESIGN SPECIFICATIONS. 2. WHEN INSTALLING UNIT, OPEN JUNCTION BOX PANEL BY REMOVING SCREWS, RECORD 3 PT CORRECTION FACTORS LISTED AND PLACE ON INSIDE DOOR OF CONTROL. CLOSE JUNCTION BOX PANEL. 3. A 45' CLASS POLE IS THE MINIMUM TO BE USED FOR THIS INSTALLATION. 4. ALL BOLTS ON PRIMARY CONNECTIONS ARE TO BE TORQUED AT 40 FT-LBS: DO NOT EXCEED! 5. PT TO BE LOCATED ON THE SOURCE SIDE. 6. USE GROUNDING LUGS ON RECLOSER AND FRAME TO PROPERLY GROUND RECLOSER. 7. NEUTRAL MAY BE DOUBLE DEADEND OR STRAIGHT THROUGH ON SPOOL AS NEEDED. 3 DEC DEM DEP DEF 2 0 X VIPER RECLOSER HORIZONTAL CONSTRUCTION 1 3/31/15 REVISED LOOSIER BURLISON ADCOCK BY CK'D APPR. 08.06-14B 7.2 OR 14.4 KV SOURCE 7.2 OR 14.4 KV SOURCE BLK BLK GRN X1 BLK GRN X2 GND 7.2 OR 14.4 KV SOURCE GRN X1 GND WHT X2 WHT X1 X2 GND WHT PT JUNCTION BOX PT 1 PT 2 PT 3 TO CONTROL BOX NOTES: 1. X1 WIRE IS BLACK, X2 WIRE IS WHITE, GROUND WIRE IS GREEN. 3 DEC 2 DEM DEP DEF WIRING DIAGRAM FOR PT CLUSTER X 1 0 12/19/14 REVISED BURLISON GUINN ADCOCK BY CK'D APPR. FOR G&W VIPER 08.06-15A POLE C PHASE SOURCE B PHASE SOURCE A PHASE SOURCE ORANGE GRN BLUE GRN RED GRN WHT GRN X1 GRN X2 X1 GND X2 X1 GND WHT BLACK BLK X2 GND BLK BLK BLK SEE NOTE 5 WHT BLK RED WIRE NUT YELLOW WIRE NUT NOT USED TO ANPHONAL CONNECTOR AT BOTTOM OF RECLOSER ALTERNATE COLOR SCHEME FOR CONTROL CABLE WITH BLUE, BLACK, RED, ORANGE AND YELLOW CONDUCTORS NOTES: WIRING DIAGRAM WOULD BE REVERSED IF POLE IS TO THE RIGHT. FOLLOW THIS CONVENTION: X2 ON ALL PHASES IS GREEN CAREFULLY REMOVE THE SECONDARY CABLE FROM THE B PHASE. THIS CABLE WILL NEED TO BE REINSTALLED ON THE C PHASE PT. BE GROUNDED TO THE LUG ON THE BACK OF THE PT IN ONE OF THESE TWO METHODS. 4. PT CONVERSION KITS HAVE BEEN CREATED AND INCLUDE: 4 STRESS RELIEF CONNECTORS, WIRE NUTS, 5. INSTALL JUMPER FROM THE X2 BUSHING TO THE GROUND BUSHING IN THE "A" PHASE PT. 3 DEC 2 DEM DEP DEF WIRING DIAGRAM FOR PT CLUSTER X 1 0 12/19/14 REVISED BURLISON GUINN ADCOCK BY CK'D APPR. ABB 1PT TO 3PT CONVERSION 08.06-15B F201 - 30A BATTERY/ BATTERY CHARGER CIRCUIT 1 F202 - 5A 12 VDC AUX SUPPLY 2 F412 - 10A 120 VAC POWER MODULE PROTECTION 3 BILL OF MATERIALS MACRO UNIT BUBBLE COMPATIBLE NUMBER UNIT 1 2 3 - - CU QTY ITEM NUMBER - 9220273322 9220237204 9220273356 ITEM QTY/ CU 1 1 1 DESCRIPTION CONTROL, BATTERY CHARGER CKT, SEL 651 RECLOSER CONTROL - F201-30A CONTROL, 12VDC AUX SUPPLY, SEL 651 RECLOSER CONTROL - F202-5A CONTROL, 120VAC POWER MODULE, SEL 651 RECLOSER CONTROL - F412-10A 3 DEC 2 DEM DEP DEF FUSE AND BATTERY FOR SEL 651-R2 CONTROLS X 1 0 12/19/14 REVISED BURLISON GUINN ADCOCK BY CK'D APPR. (ABB & VIPER) 08.06-15C F404 - F406 6A SOURCE SIDE PT FUSES F401 - F403 6A LOAD SIDE PT FUSES F-408 AND F410 COPPER PLUG DUMMY FUSES IN NEUTRAL CIRCUITS F407 - 30A 120 VAC POWER MODULE PROTECTION F411 15A 120 VAC GFCI PROTECTION BILL OF MATERIALS MACRO UNIT BUBBLE COMPATIBLE CU NUMBER UNIT QTY 1 2 3 4 - - - ITEM NUMBER 1028160 9220226465 9220237208 9220284497 ITEM QTY/ CU 1 1 1 1 DESCRIPTION CONTROL, PT VOLTAGE, SEL 651 RECLOSER CONTROL - F401-F406-6A CONTROL, AC POWER SUPPLY & HEATER, SEL 651 RECLOSER CONTROL - F407-F410-30A CONTROL, GFCI OUTLET, SEL 651 RECLOSER CONTROL - F411-15A BATTERY, LEAD ACID SEALED, 16 A H, SEL 651R CONTROL 3 2 DEC 2/19/16 LOOSIER BURLISON ADCOCK 1 7/17/15 LOOSIER BURLISON ADCOCK 0 12/19/14 BURLISON GUINN ADCOCK BY CK'D APPR. REVISED DEM DEP DEF FUSE AND BATTERY FOR SEL 651-R2 CONTROLS (ABB & VIPER) X 08.06-15D SPECIAL PROVISIONS FOR G&W VIPER ST INSTALLATIONS AT INTERCONNECTIONS WITH IPPS (INDEPENDENT POWER PRODUCERS): 1. IN DWG. 08.06-11A , THE SIDE OF THE RECLOSER REFERENCED AS THE SOURCE VERTICAL BUSHING SIDE 2. IN DWG. 08.06-11A , THE SIDE OF THE RECLOSER REFERENCED AS THE LOAD HORIZONTAL BUSHING ITEM # 260123 ) MUST BE UNBOLTED AND REMOVED FROM THE SWITCH BEFORE IT IS MOUNTED. (EACH PHASE HAS SOURCE AND LOAD DISCONNECT BLADES THAT ARE PARALLEL TO EACH OTHER, AND THESE ARE LEFT ALONE. ONLY THE BYPASS BLADE, HORIZONTAL TO THE OTHERS, IS TO BE REMOVED. WHEN READY, THE SWITCHES WILL HAVE 6 BLADES INSTEAD OF 9. THIS IS DONE BECAUSE AN IPP INTERTIE RECLOSER MUST NEVER BE BYPASSED, SINCE THERE IS NO BACKUP PROTECTION TO ASSURE PROPER OPERATION OF THE IPP WITH OPERATION OF THE IPP WITH THE UTILITY.) 4. SEL 651R RELAYS AT IPP INTERCONNECTIONS HAVE SETTINGS, DISPLAY PANELS, AND BUTTONS THAT ARE NOT THE SAME AS A REGULAR LINE RECLOSER. THE PROPER SETTINGS AND FACEPLATE LABELS ARE AVAILABLE FROM THE COMPANY PROTECTION ENGINEER AND ARE TO BE APPLIED AT TIME OF RELAY PROVISIONING. 5. SEE DWGS. 11.09-10 OR 11.09-20 FOR CONSTRUCTION DETAILS FOR THE IPP PRIMARY METERING POLE LOCATED ONE SPAN AWAY, CLOSER TO THE IPP. 3 DEC 2 DEM DEP DEF SPECIAL PROVISIONS - X 1 0 4/18/16 REVISED BRAVO BURLISON ADCOCK BY CK'D APPR. G&W VIPER ST, IPP INTERCONNECTION 08.06-15E BRACKET - CN 9220272934 ANTENNA - CN 9220272935 INSTALLATION NOTES: 1. FOLLOWING STANDARD OPERATING PROCEDURES AND SAFETY MEASURES, BYPASS THE ABB RECLOSER AND OPEN ALL THREE SOURCE AND LOAD SIDE DISCONNECTS TO COMPLETELY DE-ENERGIZE THE RECLOSER. 2. DISCONNECT THE BATTERY IN THE EXISTING CONTROL. 3. UNPLUG THE CONTROL CABLE AND SAFELY MOVE IT OUT OF THE WAY. 4. DISCONNECT THE GROUNDING CONNECTION TO THE EXISTING CONTROL. 5. LOOSEN BOLTS AND REMOVE CONTROL FROM POLE. 6. MOUNT THE NEW CONTROL. USE THE SAME TOP BOLT, THE BOTTOM BOLT WILL NEED TO BE REDRILLED. 7. CONNECT GROUND TO CONTROL BOX. 8. PLUG THE CONTROL CABLE INTO THE NEW CONTROL. INSTALL PLUG GUARD OVER THE PLUG 10. INSTALL ANTENNA AND CONDUIT WITH ANTENNA WIRE INSIDE. SECURE CONDUIT TO POLE WITH STRAPS. 11. REMOVE COVER FROM 1" PREDRILLED HOLE IN BOTTOM OF CONTROL. FEED CABLE THROUGH 1" HOLE AND ATTACH CONDUIT. 12. CONNECT THE 3 ANTENNA WIRES TO THE MODEM INSIDE CONTROL. SEE DWG. 08.06-16B FOR DETAIL. 13. CLOSE THE SOURCE SIDE DISCONNECTS. CONTROL AND MODEM SHOULD COME TO LIFE. 14. FOLLOW INSTRUCTIONS FOR COMMISSIONING CONTROL. 15. WHEN GIVEN OK - CLOSE LOAD SIDE DISCONNECTS AND FOLLOW STANDARD PROCEDURES TO RESTORE RECLOSER TO SERVICE. 16. WHEN RELOCATING THE CONTROL BOX, IF IT REMAINS ON THE SAME FEEDER, IT WILL RETAIN THE SAME EQUIPMENT ID. IF THE DEVICE IS RELOCATED TO A DIFFERENT FEEDER, THEN THE DEVICE WILL REQUIRE A NEW EQUIPMENT ID AND WILL REQUIRE NEW SETTINGS TO BE UPLOADED. 3 DEC 2 DEM DEP DEF ABB TO SEL 651-R2 CONTROL CONVERSION ON X 1 0 12/19/14 REVISED BURLISON GUINN ADCOCK BY CK'D APPR. ABB RECLOSERS 08.06-16A THERE ARE THREE CABLES COMING FROM THE ANTENNA. THE SMALL CABLE IS THE GPS AND MUST BE SCREWED INTO THE MIDDLE SPOT ON THE BACK OF THE MODEM. THE TWO LARGER CABLES ARE INTERCHANGEABLE. SCREW THEM INTO THE OTHER TWO SPOTS. MODEM - CN 9220272933 MODEM MUST BE CONFIGURED BY TELECOM 3 DEC 2 DEM DEP DEF ABB TO SEL 651-R2 CONTROL CONVERSION ON X 1 0 12/19/14 REVISED BURLISON GUINN ADCOCK BY CK'D APPR. ABB RECLOSERS 08.06-16B 5" 6" 2" 11" 4 48" 1 31" 6" 2 3 8 48" 6 35" 5 72" L1 NEUTRAL 12" SECONDARY L2 BLACK #6 SD BC TERMINAL L1 GREEN - GROUND 9 BLACK SECONDARY ARRESTER SECONDARY ARRESTER CONNECTION 38" 4 HOLE SPADE ON RECLOSER LOCKWASHER 1/2" SS BOLT 48" MIN. BOLT ON TAMPER GUARD FOR CONTROL CABLE PLUG NUT #6 BC ROUND WASHER ROUND BOLT #6 BC FRONT VIEW SIDE VIEW DETAIL "B" NOTES: 1. 2. 3. 4. 5. SEE DWG. 08.06-22B FOR BILL OF MATERIALS. CONTROL BOX AND SECONDARY REQUIRED FOR ELECTRONIC RECLOSER ONLY. ISSUE RECLOSER AND ELECTRONIC CONTROL SEPARATELY. RECLOSER MAY BE REVERSED IN HANGER TO ACCOMMODATE SOURCE AND LOAD POSITION. WHEN END MOUNTING THREE-PHASE RECLOSER, USE A MINIMUM OF A 45 FT. CLASS 4 WOOD POLE. 3 RECLOSER ASSEMBLY, THREE-PHASE, VERTICAL 2 1 11/6/13 SALAS 0 10/19/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DANNA ADCOCK 600 AMP SWITCH DWG. 08.06-22A BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156BYPF 3 2 3 4 5 BKTFBGPIN15138F IPIN25PF TTIEF500COVALPF AREQOH10F 4 4 4 6 6 KLC2H50ALF 6 7 8 KLC2H50AL90DF RCRISER500ALF 6 6 9 CRIS1UGPVC225CF 2 10 AREQSC120F 1 11 GOCE6F 1 - CATALOG NUMBER 013264 013308 152107 260123 9220087868 9220091018 9220068094 220202 010928 012277 013163 155326 10542504 9220068102 202112 323422 434122 434142 220139 013264 013308 152107 153111 160123 190404 QTY PER CU 2 2 2 1 1 1 1 1 2 2 4 1 2 1 12 1 0.2 3 1 2 2 1 1 1 4 DESCRIPTION WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 3-SLD BLADE DISC,, 15KV, LBK BRACKET, FIBERGLASS STAND-OFF, 1-3/8" THREAD INSULATOR, 25 KV POLYMER, 1 3/8" THREAD PLASTIC TIE WRAP FOR 2-7/8" F-NECK INSULATOR ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, 1/2" X 2" NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H 500 AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD LUG, 2-HOLE, TIN-PLATED, NEMA, 90 DEGREE CABLE, XLP UG AL 500 GUARD, PVC, CABLE, 2-1/4" X 10' BANDING, STAINLESS STEEL, 316, SS, 3/4" WIDE, .030 TH BANDING, BUCKLE, SS, 3/4", FOR BANDING ARRESTER, LIGHTNING, SEC 120-240 3 WIRE WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 12" CONNECTOR, COMP, AL, A=2/0STR-2SOL, B=2STR-6SOL CONNECTOR, GND, 5/8, ROD, 2, CU WIRE, COPPER, #6, SOFT DRAWN, CU, BR, SDW, SLD, #6 ADDITIONAL MATERIALS FOR ELECTRONIC RECLOSER ONLY MACRO UNIT - CU/CN ITEM NO. 16 17 18 19 20 21 22 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER - - 220133 323422 373379 372172 381674 372102 - QTY PER CU 1 2 2 1 1 1 1 DESCRIPTION ARRESTER, SECONDARY, 650V CABLE GUARD, PLASTIC, 2-1/4" X 10" ADAPTER, PVC, MALE, SCH 40 NUT, 1", STEEL CONDUIT CONDUIT, 1", PVC, SCH 40 CONTROL, ELECTRONIC (ISSUE SEPARATELY) NOTES: 1. SEE DWG 08.06-22A FOR DESIGN SPECIFICATIONS. 2. SEE DWG 03.06-04 FOR PIN INSULATOR DETAILS. 3 RECLOSER ASSEMBLY, THREE-PHASE, VERTICAL, 2 R 1 0 10/19/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. 600 AMP SWITCH DWG. 08.06-22B SWITCH, BYPASS, SINGLE-PHASE 1 2 15 KV SWITCH, BYPASS, SINGLE-PHASE BRACKET IS INCLUDED WITH SWITCH 25 KV SWITCH, BYPASS, SINGLE-PHASE BRACKET IS INCLUDED WITH SWITCH BILL OF MATERIALS CU ITEM NO. MACRO UNIT COMPATIBLE UNIT QTY REQ'D 1 SW156BYPF 1 2 SW256BYPF 1 - CATALOG NUMBER 013264 013308 152107 260123 013264 013308 152107 260552 QTY PER CU 2 2 2 1 2 2 2 1 DESCRIPTION WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", SQUARE, FLAT BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 600A, 15KV, W/ BRACKET WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", SQUARE, FLAT BOLT, MACH, SQ, NUT, 5/8" X 12" SWITCH, BYPASS, 600A, 25KV, W/ BRACKET NOTES: 1. THE FACE OF POLE SHOULD BE LEFT CLEAR FOR OPERATION OF VERTICAL MOUNTED SOLID BLADE SWITCHES. AVOID MOUNTING STREET LIGHT BRACKETS AND OTHER SIMILAR EQUIPMENT ON THESE POLES. 3 2 BYPASS SWITCHES 1 0 8/23/10 REVISED R GUINN GUINN ELKINS DWG. BY CK'D APPR. 08.10-10 5" 9" NEUTRAL 4" 4" 28-3/4" 44" SEE NOTE 4 15-1/4" 2 4" 4" 28-3/4" 4 1 SEE NOTE 3 44" 6 3 15-1/4" 4" 4" 28-3/4" 5 PLAN VIEW 72" #6 SD BC FRONT VIEW NOTES: 1. THIS POLE SHOULD BE OFFSET WHEN POSSIBLE SO THAT CONDUCTORS STAY IN LINE. 2. SEE DWG. 08.10-12B FOR BILL OF MATERIALS. 3. ARRESTERS APPLIED ONLY IN NORMAL OPEN CONFIGURATION. 4. CAN USE EITHER 20" OR 30" STANDOFF BRACKET AS REQUIRED BY FIELD CONDITIONS. 3 7/1/15 LOOSIER BURLISON ADCOCK 2 3/31/15 LOOSIER WHITE ADCOCK 1 1/23/13 DANNA DANNA ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF X SWITCH MOUNTING IN VERTICAL DOUBLE CIRCUIT 08.10-12A BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156SBDF 3 2 BKTLASWBKTSTLF 3 3 BKTSBDSWSTLF 3 4 AREQOH10F 9 5 BKTCOLASNGSTLF 3 6 KHLC7933F 6 - CATALOG NUMBER 010928 012277 013128 013407 152074 260136 010928 012277 070283 10542504 013264 013308 070282 152107 220202 193511 013264 013308 152106 311263 9220184794 QTY PER CU 4 4 4 8 2 1 2 2 1 2 2 2 1 2 1 2 2 2 2 1 1 DESCRIPTION BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD,1 /2"X2" NUT, HEX, 1/2 IN, A304, STAINLESS STEEL WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR,1/2" BOLT, MACH, HEX, HD, 1/2"X2" SWITCH, DISCONNECT, SOLID BLADE, 15KV, 600A, 1PH, SWITCH BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, 1/2" X 2" NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE, THREAD BRACKET, MNTG SWITCH ARSTR WASHER, RD, 1/2, SS, 1.375" OD WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16 BRACKET, MNTG WD/CNCR POLE BOLT, MACH, SQ, NUT, 5/8" X 12" ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER P CABLE, 600V, #6 SD BC WASHER, SPRING, COIL, STEEL, FOR 5/8", BOLT, GALV. WASHER, 2-1/4", SQUARE, FLAT, 13/16", HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 10" BRACKET, SGL MT CONNECTOR, HOT LINE CLAMP, 795 MCM TO 336 MCM NOTES: 1. SEE DWG. 08.10-12A FOR DESIGN SPECIFICATIONS. 3 2 4/9/13 McCONNELL DANNA ADCOCK 1 1/6/12 HOFFMAN BURLISON ELKINS 0 11/29/10 HOFFMAN GUINN ELKINS DWG. BY CK'D APPR. 08.10-12B REVISED SWITCH MOUNTING IN VERTICAL DOUBLE CIRCUIT 3 DETAIL "A" PLAN VIEW 2 3" TYP. 5" CL BOLT HOLE (TYP.) 8" 3" TYP. 28-3/4" 22" SEE DETAIL "A" 1 44" 15-1/4" 22" SEE NOTE 4 28-3/4" 22" 16" MIN. TYP. 44" 15-1/4" 22" 28-3/4" TO STRAIGHT THROUGH CIRCUIT (FAR SIDE CONDUCTOR NOT SHOWN FOR CLARITY) 4 72" NEUTRAL FRONT VIEW SIDE VIEW NOTES: 1. SEE DWG 08.10-14B FOR BILL OF MATERIALS. 2. THIS POLE SHOULD BE OFFSET WHEN POSSIBLE SO THAT CONDUCTORS STAY IN LINE. 3. MAINTAIN A MINIMUM CLEARANCE OF 16" BETWEEN JUMPERS AND PHASES. 4. CAN USE EITHER 20" OR 30" STANDOFF BRACKET AS REQUIRED BY FIELD CONDITIONS. 3 2 DEC 6/17/15 LOOSIER BURLISON ADCOCK 1 11/6/13 SALAS DANNA ADCOCK 0 8/23/10 GUINN GUINN ELKINS BY CK'D APPR. REVISED DEM DEP DEF 600 AMP DOUBLE CIRCUIT TIE SWITCH X 08.10-14A BILL OF MATERIALS MACRO UNIT CU/CN ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156SBDF 3 2 BKTSBDSWSTLF 3 3 4 KWP4H79F - 3 - - CATALOG NUMBER 260136 012277 013128 010928 013407 152074 070282 013264 152107 013308 165288 9220068328 QTY PER CU 1 4 4 4 8 2 1 2 2 2 1 2 DESCRIPTION SWITCH, SOLID BLADE 600 AMP NUT, SS, HEX WASHER, ROUND, BELLEVILLE, SPRING BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" WASHER, ROUND, FLAT, SS BOLT, MACHINE, HEX HEAD, 1/2" X 2" BRACKET, MOUNTING WD/CONCRETE POLE WASHER, SPRING, COIL, FOR 5/8", STL, GALV. BOLT, MACHINE, SQ, 5/8" X 12" WASHER, 2-1/4", SQUARE FLAT, 13/16" HOLE CONNECTOR, WEDGE, 4-HOLE, 795 AAC SIGN, CAUTION FEEDER TIE SWITCH NOTES: 1. SEE DWG 08.10-14A FOR DESIGN SPECIFICATIONS. 3 2 600 AMP DOUBLE CIRCUIT 1 4/9/13 McCONNELL 0 8/23/10 GUINN GUINN ELKINS BY CK'D APPR. REVISED DANNA ADCOCK TIE SWITCH DWG. 08.10-14B 5" LOAD LINE 2" TYP. 36" 4 5 3 2 SEE NOTE 2 36" 1 72" NEUTRAL #6 SD BC #6 SD BC FRONT VIEW SIDE VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 1 COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER SW153COSBDF SW253COSBDF 3 3 2 BKTCOLADBLSTLF 3 3 BKTCOLASNGSTLF 3 4 AREQOH10F KHLC40N6F KHLC7933F 6 6 6 9220210916 9220210993 013264 013308 070106 152107 013264 013308 152106 311263 220202 9220184790 9220184794 - - 5 QTY PER CU 1 1 2 2 1 2 2 2 2 1 1 1 1 DESCRIPTION 15KV CUTOUT WITH 300A SOLID DOOR 25KV CUTOUT WITH 300A SOLID DOOR WASHER, LOCK, 5/8", STEEL, GLV, SPRING, DOUBLE COIL, STEEL, F WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLD, GLV BRACKET, ARRESTER AND CUTOUT, DBL MNTG BOLT, MACHINE, SQUARE, NUT, 5/8" X 12" WASHER, SPRING, COIL, STEEL, FOR 5/8", BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, 5/8" X 10", STEEL, A-ASTM A307, GALV BRACKET, SINGLE MOUNT ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY CLAMP, HOT LINE, ALUM, SMALL, 4/0 CLAMP, HOT LINE, ALUM, LARGE, 336-795 NOTES: 1. 300 AMP DISCONNECT IS AVAILABLE 15KV AND 25KV (COASTAL AND HOLOPAW). 2. ARRESTERS APPLIED ONLY IN NORMAL OPEN CONFIGURATION. 5 3/31/15 4 5/31/13 3 4/15/13 0 8/23/10 REVISED LOOSIER WHITE ADCOCK DANNA ADCOCK DANNA ADCOCK GUINN GUINN ELKINS BY CK'D APPR. DEC DEM DEP SWITCH ASSEMBLY, 300 AMP, SOLID BLADE, VERTICAL DEF X 08.10-16 5 PLAN VIEW 3 CL BOLT HOLE (TYP.) 8" 5" 28-3/4" 1 6 44" 15-1/4" 28-3/4" 2 4 44" SEE NOTE 2 15-1/4" 28-3/4" 72" 1 NEUTRAL #6 SD BC FRONT VIEW SIDE VIEW NOTES: 1. SEE DWG. 08.10-18B FOR BILL OF MATERIALS. 2. ARRESTERS APPLIED ONLY IN NORMAL OPEN CONFIGURATION. 5 6/17/15 LOOSIER BURLISON ADCOCK 4 3/31/15 LOOSIER WHITE ADCOCK 3 10/29/14 LOOSIER DANNA ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF SWITCH ASSEMBLY, 600 AMP, SOLID BLADE, VERTICAL X 08.10-18A BILL OF MATERIALS MACRO UNIT CU ITEM NO. - COMPATIBLE UNIT QTY REQ'D 1 SW156SBDF 3 2 BKTLASWBKTSTLF 3 3 BKTSBDSWSTLF 3 4 5 AREQOH10F KHLC7933F 6 6 6 KLC4H79ALF 6 CATALOG NUMBER 010928 012277 013128 013407 152074 260136 010928 012277 070283 10542504 013264 013308 070282 152107 220202 9220184794 10928 12277 13163 155464 10542504 QTY PER CU 4 4 4 8 2 1 2 2 1 2 2 2 1 2 1 1 4 4 8 1 4 DESCRIPTION BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD,1 /2"X2" NUT, HEX, 1/2 IN, A304, STAINLESS STEEL WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR,1/2" BOLT, MACH, HEX, HD, 1/2"X2" SWITCH, DISCONNECT, SOLID BLADE, 15KV, 600A, 1PH, SWITCH BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, 1/2" X 2" NUT, STAINLESS, STEEL, HEX, 304, ALLOY, COARSE, THREAD BRACKET, MNTG SWITCH ARSTR WASHER, RD, 1/2, SS, 1.375" OD WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16 BRACKET, MNTG WD/CNCR POLE BOLT, MACH, SQ, NUT, 5/8" X 12" ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER P CONNECTOR, HOT LINE CLAMP, 795 MCM TO 336 MCM BOLT, MACHINE, 1/2 IN, 2 IN, STAINLESS STEEL, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, 304, ALLOY, COARSE WASHER, FLAT, 1/2 IN, SILICON BRONZE, FLAT, ROUND, SILICON LUG, COMPRESSION, 4 HOLE, 795, AAC WASHER, ROUND, 1/2, SS, 1.375" OD 3 2 DETAIL SWITCH BRACKET NOTES: 1. SEE DWG. 08.10-18A FOR DESIGN SPECIFICATIONS. 5 6/17/15 LOOSIER BURLISON ADCOCK 4 3/31/15 LOOSIER WHITE ADCOCK 3 7/16/14 LOOSIER DANNA ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF SWITCH ASSEMBLY, 600 AMP, SOLID BLADE, VERTICAL X 08.10-18B PLAN VIEW KHLC40N6F OR KHLC7933F 6" TYP. 6" 24" 6" 60" FRONT VIEW SIDE VIEW NOTES: 1. IN LOCATIONS WHERE THE SWITCH COULD BE USED TO TRANSFER LOAD AND COULD BE LEFT IN THE OPEN POSITION FOR AN EXTENDED PERIOD OF TIME, ENGINEERING SHOULD CALL FOR LIGHTNING ARRESTERS ON BOTH SIDES OF THE SWITCH. 3 SWITCH ASSEMBLY, 300 AMP, SOLID BLADE 2 1 8/31/11 BURLISON 0 11/5/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED BURLISON ELKINS HORIZONTAL DWG. 08.10-20 10" 2 SEE NOTE 3 20" 14" 20" 18" 38" 14" 10" 34" 14" 4 5" 3 1 72" #6 SD BC FRONT VIEW SIDE VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156UHSBDF 3 1 SW256UHSBDF 3 2 AREQOH10F 6 3 ARMD8LW36FSF 1 4 KHLC7933F 6 - CATALOG NUMBER 260136 070793 260547 070793 220202 011209 011313 013264 013308 014114 031113 071306 9220184794 QTY PER CU 1 1 1 1 1 4 3 1 10 2 2 4 1 DESCRIPTION SWITCH, DISCONNECT, SOLID BLADE, 15KV, 600A, SINGLE-PHASE PLATE, SW BACKING SWITCH, DISCONNECT, SOLID BLADE, 25KV, 600A, SINGLE-PHASE PLATE, SW BACKING ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY BOLT, CARRIAGE, 3/8" X 4-1/2" BOLT, DOUBLE ARMING, 5/8", 20", STEEL, WITH 4 NUTS WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. SCREW, LAG, 1/2" X 4", STEEL, GALV. CROSSARM, WOOD, 8', MS-121-F, LIGHT BRACE, FLAT, GALV, STEEL, 36" CONNECTOR, HOT LINE CLAMP, 795 MCM TO 336 MCM NOTES: 1. 600 AMP SWITCH IS AVAILABLE FOR 15KV AND 25KV (COASTAL AND HOLOPAW). 2. SEE DWG. 03.11-01B FOR REQUIRED CROSSARM. 3. ARRESTERS APPLIED ONLY IN NORMAL OPEN CONFIGURATION. 3 DEC 2 3/31/15 1 5/31/13 0 8/23/10 REVISED LOOSIER WHITE ADCOCK DANNA ADCOCK GUINN GUINN ELKINS BY CK'D APPR. DEM DEP SWITCH ASSEMBLY, 600 AMP, SOLID BLADE HORIZONTAL DEF X 08.10-22 25" 4" 17" PLATED TERMINAL PADS DEAD-ENDING HOLE 2 3 4 4" BLADE STOP PIN 1 2-3/8" 11/16" DIA. PULL-OFF-HOLE 1-1/4" DIA. LOADBREAK HOOK 15-13/16" BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156ILSBDF 1 DECLMP(WIRE)F IDES25PF KLC2H(WIRE)ALF 2 2 2 2 3 4 CATALOG NUMBER 0000010928 0000012277 0000013128 0000013407 0000434241 0000080577 - QTY PER CU 4 4 4 8 1 1 1 1 DESCRIPTION BOLT, MACHINE, 1/2 IN, 2 IN, SS, 304, HEX HEAD NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, HEX WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, ROUND,FLAT,SS,304,ALLOY,FOR,1/2" SWITCH, DISCONNECT TEMP DEADEND CLAMP INSULATOR, DEADEND, POLYMER,25KV,DE,SILICONE, 15KV LUG, COMPRESSION, 2 HOLE NOTES: 1. SEE DWG. 08.10-18A FOR THE PREFERRED 600 AMP SWITCH INSTALLATION. INLINE SWITCHES MAY BE USED TO FACILITATE CONSTRUCTION, RESTORATION OR REPAIR. WHEN USED FOR THESE PURPOSES, THEY SHOULD BE REMOVED AT THE COMPLETION OF WORK. INLINE SWITCHES MAY BE USED FOR A PERMANENT INSTALLATION WHEN THE PREFERRED INSTALLATION IS IMPRACTICAL OR IMPOSSIBLE. 3 DEC 2 9/4/14 LOOSIER DANNA ADCOCK 1 11/21/11 ROBESON BURLISON ELKINS 0 11/5/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEM DEP DEF X 600 AMP INLINE DISCONNECT 08.10-24 5" LINE 4" 12" 28-3/4" 44" 44" LOAD 3 15-1/4" 44" 44" 2 PLAN VIEW TANGENT CONSTRUCTION 1 72" NEUTRAL 4" FRONT VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 SW156SBDF 3 2 BKTSBDSWSTLF 3 3 KWP4H79F 3 - CATALOG NUMBER 260136 012277 013128 010928 013407 152074 070282 013264 152107 013308 165288 QTY PER CU 1 4 4 4 8 2 1 2 2 2 1 DESCRIPTION SWITCH, SOLID BLADE 600 AMP NUT, SS, HEX WASHER, ROUND, BELLEVILLE, SPRING BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" WASHER, ROUND, FLAT, SS BOLT, MACHINE, HEX HEAD, 1/2" X 2" BRACKET, MOUNTING WD/CONCRETE POLE WASHER, SPRING, COIL, FOR 5/8", STL, GALV. BOLT, MACHINE, SQ, 5/8" X 12" WASHER, 2-1/4", SQUARE FLAT, 13/16" HOLE CONNECTOR, WEDGE, 4-HOLE, 795 AAC NOTES: 1. THE INTENT OF THIS DRAWING IS TO SHOW PHASE SPACING AND CIRCUIT ARRANGEMENT. PRIMARY SUPPORT CONFIGURATION MAY VARY. 2. POLE GAINS ( ISGAINGRIDF FOR 15/25KV INSULATORS OR ISGAINGRID55F FOR 35KV INSULATORS) ARE REQUIRED FOR POST INSULATOR INSTALLATIONS ON WOOD POLES WHEN THE POLE DOES NOT HAVE A SLAB GAIN FOR ALL CONDUCTOR SIZES.WHEN THE CONDUCTOR IS 336.4 KCMIL OR LARGER, USE POLE GAIN EVEN IF SLAB GAIN EXISTS. POLE GAINS ARE NOT REQUIRED FOR INSULATORS USED FOR JUMPERS. SLACK SPANS WITH 336 AND 795 CONDUCTORS REQUIRE A POLE GAIN. 3. SEE SPECIFIC CONFIGURATION DRAWINGS FOR ADDITIONAL DETAILS. 3 2 4/9/13 McCONNELL DANNA ADCOCK 1 3/21/13 McCONNELL DANNA ADCOCK 0 1/23/13 ROBESON GUINN ADCOCK BY CK'D APPR. REVISED VERTICAL TANGENT CROSSING WITH 600 AMP DISCONNECTS DWG. 08.10-26 7 8 5" 6" 24" 48" 10 24" 6" 9 48" 4 35" 6 72" 2 7 8 14 #6 SD BC 3 #6 SD BC #2 SD BC 13 1 120/208V PT SOURCE 15 16 17 18 19 20 11 LASH 200' CT & SW CABLE TO AERIAL QUADRUPLEX (COIL EXCESS) 21 #6 SD BC 12 22 20-1/8" 48" MIN. FRONT VIEW SIDE VIEW NOTES: 1. ENGINEER MUST SPECIFY JUMPER AND PRIMARY CONNECTOR SIZE. 2. REFER TO DWG. 08.12-01 FOR WIRING DIAGRAM. 3. SEE DWG. 08.12-02B FOR BILL OF MATERIALS. 4. BOND TANK AND FRAME WITH #2 SD BC TO SYSTEM NEUTRAL. 5. WHEN USING AS LOAD CONTROL ON A PRIMARY METERED CUSTOMER, PLACE THE VLR SWITCH ON THE LOAD SIDE OF THE PRIMARY METERING INSTALLATION. 3 2 11/11/13 1 5/24/13 0 11/29/10 REVISED DANNA DANNA ADCOCK DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. VLR LOAD CONTROL AND AUTO TRANSFER CONTROL SWITCH DWG. 08.12-02A BILL OF MATERIALS CU ITEM NO. MACRO UNIT COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER QTY PER CU DESCRIPTION VLR VERTICAL FRAMING - ORDER SWITCH, CONTROL AND CABLES SEPARATELY SWOVLRFRMFM 1 BKTOSVLREPF 1 2 3 4 AREQOH10F BKTCOLASTLXARMF KHLC40N6F 6 6 6 5 BKTFPIS20F 4 6 ISSTUDBOLT5814F 2 7 8 9 IHPTT15F HTIEN4AACF RCRISER40ALF 6 6 6 10 SW156BYPF 3 11 12 13 AREQSC120F SWOSCADACNTKITF FUSESEC30F 1 1 1 070467 013229 013264 013346 152094 152107 220202 070101 9220184790 070430 072361 152107 013346 013264 013264 072368 080212 200306 202111 260123 013264 013308 152107 010928 013128 013407 012277 220139 263165 230464 1 12 2 2 6 2 1 1 1 1 1 2 2 2 1 1 1 5 8 1 2 2 2 8 8 16 8 1 1 1 BRACKET, RCLSR 3PH TY 3H E-P WASHER, ROUND, FLAT, 1/2", BOLT WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, 3", SQUARE, CURVED, 13/16", HOLE BOLT, MACHINE, 1/2" X 3-1/2" BOLT, MACH, SQ, NUT, 5/8" X 12" ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY BRACKET, LA & CO TY A CLAMP, HOT LINE, ALUMINUM BRACKET, FIBERGLASS, STAND-OFF, 20" STUD, LINE POST, 5/8" X 1-3/4"- 3/4 X 1 BOLT, MACH, SQ, NUT, 5/8" X 12" WASHER, 3", SQUARE, CURVED, 13/16", HOLE WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. STUD, LINE POST, 5/8" X 14" INSULATOR, POST, TIE TOP, 15/25KV, WITHOUT STUD WIRE, AL, SLD, BR, SDW, #4, TIEWIRE CABLE, XLP UG AL 4/0 SWITCH, BY-PASS, 3-SLD BLADE DISC, 15KV, LBK HOOKS, 600A WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16", HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 12" BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, 1/2" X 2" WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, STAINLESS STEEL, 304 ALLOY, FOR 1/2" BOLT NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, COARSE, THREAD, 1 ARRESTER, LIGHTNING, SEC 120-240 3 WIRE* RISER, KIT-SCADA CONTROL FUSE, SEC INS 30 AMP VLR SWITCH USED FOR LOAD CONTROL - SWITCH AND CONTROL CABLE 14 - SW154VLRF 1 263138 264219 192281 200306 470114 1 1 30 5 6 SWITCH, OIL 15KV 3 RC 400A8 CABLE, IS1 VLR SW CNTRL 35 CABLE, CONTROL, #10, 2 - CONDUCTOR WIRE, AL, SLD, BR, SDW, #4, TIEWIRE GUARD, TRANSFORMER, WILDLIFE, ROUND, GRAY MIN. 9" VLR SWITCH USED FOR AUTO SOURCE TRANSFER SCHEME - SWITCH ONLY - ORDER CABLES SEPARATELY - 14 15 16 17 18 19 20 SW154VLRFBF SWOS1CAB35F SWOS1CAB45SWF SWOS1CAB45CTF SWOS1CAB200CTF SWOS1CAB200SWF SWOS1CAB45FBF 1 1 1 1 1 1 1 - 21 CRIS1UGPVC225CF 1 - 22 SWOHASTCNTLSF 1 263136 264219 264210 264208 264211 264212 264209 323422 434122 434142 1 1 1 1 1 1 1 1 0.2 3 SWITCH, AUTO, XFER FAULT BL CABLE, IS1 VLR SW CNTRL 35' CABLE, CNTL, TYPE S, 45' SW CABLE, CNTL, TYPE S, 45' CT CABLE, CNTL, TYPE S, 200' CT CABLE, CNTL, TYPE S, 200' SW CABLE, CNTL, TYPE S, 45' FB GUARD, PVC, CABLE, 2-1/4"X10' BANDING, STAINLESS STEEL, 316, SS, 3/4", WIDE, .030, TH BANDING, BUCKLE, SS, 3/4", FOR BANDING TYPE S CONTROL - SPECIAL ORDER 264207 1 CONTROL, OILSW TYPE S 3PH NOTES: 1. SEE DWG. 08.12-02A FOR DESIGN SPECIFICATIONS. 2. SEE DWG. 08.13-05 FOR AUTO TRANSFER WIRING DETAIL. 3 2 VLR LOAD CONTROL AND 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. AUTO TRANSFER CONTROL SWITCH DWG. 08.12-02B 4 5 5" 6" 24" 3 4" 4 5 48" 7 24" 2 6" 6 48" 42" 72" 1 24" #2 SD BC 6" 9 11 8 #6 SD BC 9 20-1/8" 48" MIN. FRONT VIEW SIDE VIEW NOTES: 1. ENGINEER MUST SPECIFY JUMPER AND PRIMARY CONNECTOR SIZE. 2. REFER TO DWG. 08.12-04C FOR WIRING DIAGRAM. 3. SEE DWG. 08.12-04B FOR BILL OF MATERIALS. 4. BOND TANK AND FRAME WITH #2 SD BC TO SYSTEM NEUTRAL. 5. ON A PRIMARY METERED CUSTOMER, PLACE THE VERSAVAC SWITCH ON THE LOAD SIDE OF THE PRIMARY METERING INSTALLATION. 3 DEC DEM DEP DEF 2 0 X VERSAVAC LOAD CONTROL 1 5/1/15 REVISED DANNA BURLISON ADCOCK BY CK'D APPR. 08.12-04A BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 COMPATIBLE UNIT QTY REQ'D ITEM NUMBER BKTLCVVACEPF 1 2 BKTFBFGPIN15138F 4 9220278631 013264 013346 152107 9220087868 QTY PER CU 1 2 2 2 1 3 ISSTUDBOLT5814F 8 4 5 6 IPIN25PF TTIEF500COVALPF RCRISER40ALF 4 4 6 7 SW156BYPF 3 8 9 10 AREQSC120F SWOSCADACNTKITF FUSESEC30F 1 1 1 013264 072368 9220091018 9220068094 202111 260123 013264 013308 152107 010928 013128 013407 012277 220139 263165 230464 1 1 1 5 8 1 2 2 2 8 8 16 8 1 1 1 SWOVLRFRMFM DESCRIPTION BRACKET, VERSAVAC, 3PH TY 3H E-P WASHER, LOCK, 5/8 IN, STEEL, GLV, SPRING, DOUBLE COIL, F WASHER,3", SQUARE, CURVED, 13/16", HOLE BOLT, MACH, SQ, NUT, 5/8" X 12" BRACKET, FIBERGLASS STAND-OFF, 1-3/8" THREAD WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. STUD, LINE POST, 5/8" X 14" INSULATOR, 25 KV POLYMER, 1-3/8" THREAD PLASTIC TIE WRAP FOR 2-7/8" F-NECK INSULATOR CABLE, XLP UG AL 4/0 SWITCH, BY-PASS, 3-SLD BLADE DISC, 15KV, LBK HOOKS, 600A WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16", HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8" X 12" BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD, 1/2" X 2" WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, STAINLESS STEEL, 304 ALLOY, FOR 1/2" BOLT NUT, HEX, 1/2 IN, A304, STAINLESS STEEL, COARSE, THREAD, 1 ARRESTER, LIGHTNING, SEC 120-240 3 WIRE* RISER, KIT-SCADA CONTROL FUSE, SEC INS 30 AMP VERSAVAC SWITCH USED FOR LOAD CONTROL - SWITCH AND CONTROL CABLE 11 SW152VVACF 1 12 13 AREQOH10F KHLC40N6F 6 6 - SW154VLRF SWOHASTCNTLAKF 1 1 - 9220278629 264219 192281 0011060100 470114 220202 9220184790 1 1 30 5 6 1 1 SWITCH, VACUUM, 15KV 200A CABLE, IS1 VLR SW CNTRL 35 CABLE, CONTROL, #10, 2 - CONDUCTOR WIRE, TIE, #4 ALUMINUM, SLD GUARD, TRANSFORMER, WILDLIFE, ROUND, GRAY MIN. 9" ARRESTER, LIGHTNING, 10KV, HD MOV CLAMP, HOT LINE, ALUM, SMALL, 4/0 VLR SWITCH - FOR REMOVAL ONLY - 263138 263136 1 1 SWITCH, OH, 15KV, 400A, COOPER VLR, LD BRK SWITCH, OH, 15KV, 400A, COOPER VLR, W/FAULT BLOCK, LD BRK NOTES: 1. SEE DWG. 08.12-04A FOR DESIGN SPECIFICATIONS. 3 DEC DEM DEP DEF 2 1 12/2/15 LOOSIER BURLISON ADCOCK 0 5/1/15 DANNA BURLISON ADCOCK BY CK'D APPR. REVISED X VERSAVAC LOAD CONTROL 08.12-04B N SECONDARY SERVICE 120V VLR SWITCH SECONDARY ARRESTER SECONDARY INDICATING FUSE TERMINAL STRIP IN VLR SWITCH CONTROL CABINET WHITE TWO WIRE CABLE 4 BLACK 3 BLACK RED G 2 WHITE 1 GREEN 0 6 PIN PLUG 120V N GREEN RED GREEN 1 FOUR WIRE CABLE WHITE WHITE G RED 2 BLACK BLACK 3 TERMINAL STRIP IN RADIO SWITCH ALTERNATE CONSTRUCTION TERMINAL WIRE FUNCTION 120V BLACK 120V FROM SOURCE N WHITE NEUTRAL FROM SOURCE 1 GREEN POWER TO SWITCH G WHITE NEUTRAL TO SWITCH 2 RED 3 BLACK CLOSE TIP 3 DEC 2 DEM DEP DEF CONNECTION DIAGRAM FOR X 1 0 5/1/15 REVISED DANNA BURLISON ADCOCK BY CK'D APPR. VERSAVAC SWITCH 08.12-04C 9" 5" 4 4" 5" CL BOLT HOLE (TYP.) 40" 1 117-7/8" 40" 10 72" 9 3 7 8 #6 SD BC 5 SIDE VIEW 2 NOTES: 1. SEE DWG. 08.12-06B FOR PLAN VIEW, NOTES AND BILL OF MATERIALS. 48" MIN. FRONT VIEW 3 DEC 2 DEM DEP DEF LOAD CONTROL SWITCH 1 1/26/16 LOOSIER BURLISON ADCOCK 0 8/27/15 LOOSIER BURLISON ADCOCK BY CK'D APPR. REVISED 600 AMP X 08.12-06A 9 10 4 1 PLAN VIEW (CONTROL OPERATOR REMOVED FOR CLARITY) BILL OF MATERIALS MACRO UNIT BUBBLE NUMBER - COMPATIBLE UNIT ITEM NUMBER CU QTY 1 SW2512ALDF 1 2 SWOHASTCNTLAKF 1 2 SWOHASTCNTLAF 1 3 4 - - 5 CRIS1UGPVC10WF 15 6 7 8 CABGRP1X125F WUSNGDPXRF - 1 1 - 9 SW156SBDF 3 10 BKTSBDSWSTLF 3 9220270022 013264 13307 152107 9220269976 013264 13307 152107 9220279778 013264 13307 152107 152107 155331 014111 323421 320452 202107 010928 012277 013128 013407 152074 260136 013264 013308 070282 152107 ITEM QTY/ CU 1 2 2 2 1 2 2 2 1 2 2 2 2 6 15 1 1 30 4 4 4 8 2 1 2 2 1 2 DESCRIPTION SWITCH, OVERHEAD, 15KV 1200A, 3PH, ALDUTI-RUPTER, FBGLASS WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, 2-1/4",SQUARE,FLAT,11/16",HOLE BOLT, MACHINE, SQ NUT, 5/8" X 12" SWITCH, CONTROL, OPERATOR, ALDUTI-RUPTER SWITCH, KIRK KEY WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, 2-1/4",SQUARE,FLAT,11/16",HOLE BOLT, MACHINE, SQ NUT, 5/8" X 12" SWITCH, CONTROL, OPERATOR, ADULTI-RUPTER, W/O KIRK KEY WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, 2-1/4",SQUARE,FLAT,11/16",HOLE BOLT, MACHINE, SQ NUT, 5/8" X 12" BOLT, MACHINE, SQ NUT, 5/8" X 12" LUG, COMPRESSION, 2H - 795 AL SCREW, LAG, 1/2" X 2" 1" X 10 FT U GUARD CABLE GRIP, SINGLE EYE #6 DPX 600V SL CABLE #6 CU GND BOLT, MACHINE, STAINLESS, STEEL, HEX, HEAD,1 /2"X2" NUT, HEX, 1/2 IN, A304, STAINLESS STEEL WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR,1/2" BOLT, MACH, HEX, HD, 1/2"X2" SWITCH, DISCONNECT, SOLID BLADE, 15KV, 600A, 1PH, SWITCH WASHER, SPRING, COIL, STEEL, 5/8", BOLT, GALV WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16 BRACKET, MNTG WD/CNCR POLE BOLT, MACH, SQ, NUT, 5/8" X 12" NOTES: 1. SEE DWG. 08.12-06A FOR DESIGN SPECIFICATIONS. 2. JUMPERS SHALL MATCH CONDUCTOR SIZE. 3. USE AS A LOAD CONTROL SWITCH WHERE A KIRK KEY SYSTEM IS IN PLACE. 4. PLACE SWITCH ON LOAD SIDE OF PRIMARY METERED CUSTOMERS. 5. FOR SWITCH OPERATOR WITHOUT KIRK KEY, USE ITEM # 9220279778 . 3 DEC 2 DEM DEP DEF LOAD CONTROL SWITCH 1 12/2/15 LOOSIER BURLISON ADCOCK 0 8/27/15 LOOSIER BURLISON ADCOCK BY CK'D APPR. REVISED 600 AMP X 08.12-06B TAP CUSTOMER TO THIS POLE 120/208V 120/208V PRIMARY 400A VLR SWITCH SW CT CT N SECONDARY SW PT PT TYPE "S" CONTROL AN OVERHEAD AUTOMATIC TRANSFER SCHEME IS SHOWN IN THE ABOVE DRAWING. A MINIMUM OF FIVE POLES ARE REQUIRED FOR THE INSTALLATION. THE TWO OUTSIDE POLES EACH HAVE A THREE-PHASE WYE-WYE 120/208V TRANSFORMER STATION. THESE STATIONS ARE CONSTRUCTED WITH SMALL KVA TRANSFERS AND ARE CONNECTED TO A SMALL QUADRUPLEX CABLE WHICH RUNS TO THE NEUTRAL POSITION OF THE POLE WITH THE TYPE "S" AUTOMATIC TRANSFER CONTROL. THE QUADRUPLEX CABLE IS OPENED AT THIS POLE AND SPLICED TO THE TWO 45' PT CABLES WHICH CONNECT TO THE TYPE "S" CONTROL. THE 45' CT AND 45' SW CABLES ARE CONNECTED TO THE 400A VLR SWITCH ON THE SAME POLE AS THE TYPE "S" CONTROL. THE 200' CT AND THE 200' SW CABLE ARE INSTALLED UP THE POLE WITH THE TYPE "S" CONTROL AND THEN LASHED TO THE QUADRUPLEX CABLE GOING TO THE OTHER 400A VLR SWITCH. THE LOAD IS CONNECTED TO THE CIRCUIT BETWEEN THE TWO VLR SWITCHES. THE TRANSFER SWITCHES WILL MAKE AN OPEN TRANSFER (OPEN & THEN CLOSE) UPON LOSS OF ONE OR MORE PHASE VOLTAGES (THREE-PHASE SENSING) ON THE PREFERRED SOURCE PROVIDED THE FAULT IS NOT ON THE TRANSFERRED CIRCUIT (FAULT BLOCK FEATURE). EITHER SOURCE CAN BE CHOSEN AS THE PREFERRED SOURCE FROM THE CONTROL SELECTIONS. THE RETRANSFER TIME AND OPEN OR CLOSE TRANSITION IS SELECTABLE. IT IS ALSO POSSIBLE TO SELECT NO PREFERRED SOURCE IN WHICH CASE NO RETRANSFER OCCURS. 3 2 OVERHEAD AUTOMATIC TRANSFER SCHEME 1 0 8/25/10 REVISED R HOFFMAN GUINN ELKINS DWG. BY CK'D APPR. 08.13-01 LAMP TEST SWITCH (S6) LATCH RELAY STATUS TEST TERMINALS (T-1, T-2, T-3) SWITCH I OPEN AND CLOSED LAMPS SWITCH II OPEN AND CLOSED LAMPS PREFERRED-TOALTERNATE TIMER ALTERNATE-TOPREFERRED TIMER OPERATION SELECTOR SWITCH (S3) SOURCE I ENERGIZED LAMP SOURCE II ENERGIZED LAMP MANUAL OPERATION SOURCE I AND SOURCE II SWITCHES (S1, S2) SOURCE-PREFERENCE AND RETURN MODE SELECTOR SWITCH (S4) CONTROL MODE SWITCH (S5) LOCKING TAB FUSES STOP SCREW INSTRUCTION TAG 16" 8" 12-13/16" (2) MTG HOLES FOR 5/8" MAX BOLT DIA. 1-1/2" 20-1/8" 22-5/32" 17-7/8" 5/8" HOLE PROVIDED FOR CUSTOMER LOCK GROUNDING TERMINAL LUG (14 TO 4 STRANDED) 11" 13-1/2" 2-1/2" 2-1/2" 2-1/2" 2-1/2" 3" STD CONTROL 5-1/4" CONTROL WITH FAULT BLOCK 3 2 VLR TYPE S TRANSFER CONTROL 1 0 9/7/10 REVISED R GUINN GUINN ELKINS DWG. BY CK'D APPR. 08.13-03 5" 6" 24" 48" 24" 6" 48" 35" #6 SD BC 72" #6 SD BC #2 SD BC 120/208V PT SOURCE I 120/208V PT SOURCE II LASH 200' CT & SW CABLE TO AERIAL QUADRUPLEX (COIL EXCESS) #6 SD BC SEE DETAIL 'A' 48" MIN. 48" MIN. FRONT VIEW SIDE VIEW SOURCE II SOURCE I CT PT SW SW PT CT DETAIL "A" NOTES: 1. SEE DWG. 08.13-01 FOR OVERVIEW OF ENTIRE OVERHEAD AUTOMATIC TRANSFER SCHEME. 2. SEE DWG. 08.12-02B FOR BILL OF MATERIALS. 3. BOND TANK AND FRAME WITH #2 SD BC TO SYSTEM NEUTRAL. 4. THE OTHER POLE IN TRANSFER SCHEME WILL BE IDENTICAL, EXCEPT NO S TRANSFER CONTROL. 3 AUTOMATIC TRANSFER SWITCH ASSEMBLY, (VLR), 2 R 1 0 11/29/10 REVISED GUINN GUINN ELKINS BY CK'D APPR. CONTROL WIRING DETAIL DWG. 08.13-05 SOURCE LOAD 5" 11" 10" 42" 10" 9 13 14 64" 42" 1 4" SEE NOTE 1 2 35" 72" #2 SD BC 11 12 12" 31'-8" MAX. FOR CONTROL CABLE 4 #6 SD BC 19 30" 4' ABOVE GROUND FRONT VIEW SIDE VIEW (LOOKING FROM LOAD SIDE) NOTES: 1. ROTATE B PHASE STANDOFF AS NECESSARY TO CLEAR THE CONTROL BOX. 2. SEE DWG. 08.13-08B FOR PLAN VIEW. 3. SEE DWG. 08.13-08C FOR BILL OF MATERIALS. 3 2 SCADA MATE CX SWITCH 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. STANDARD MOUNTING ARRANGEMENT DWG. 08.13-08A 34-3/8" 23-1/16" SOURCE LOAD 3 8 15 PLAN VIEW NOTES: 1. SEE DWG. 08.13-08A FOR DESIGN SPECIFICATIONS. 2. SEE DWG. 08.13-08C FOR BILL OF MATERIALS. 3 2 SCADA MATE CX SWITCH 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. STANDARD MOUNTING ARRANGEMENT DWG. 08.13-08B BILL OF MATERIALS CU ITEM NO MACRO UNIT - COMPATIBLE UNIT QTY REQ'D 1 SW15S6VRTSATSF (SEE NOTE 1) 1 1 SW15S9VRTSATSF (SEE NOTE 1) 1 2 SW156BYPF 3 3 AREQOH10F 6 4 CRIS1UGPVC225CF 2 5 AREQSC120F 1 6 KLC2H79ALF 12 7 KLC4H79ALF 6 8 9 10 KHLC7933F TTIEF795ALF WOCN6CU1CF 6 6 6 11 SWOSANTKITF 1 12 SWOSANTBRKF 1 13 BKTFPIS20F 3 14 15 IHPTT15F IDES25PF 3 12 16 ISEYEBOLT5810F 6 17 18 DECLMP795AACF WOP795AACF 6 60 19 SWOS5201CTRF 1 CATALOG NUMBER 013265 013308 152122 9220179952 013264 152107 152123 011708 013128 013407 152122 266178 013265 013308 013264 152107 152123 011708 013128 013407 152122 013264 013308 152107 260123 220202 323422 434122 434142 220139 010928 012277 013163 155331 10542504 010928 012277 013163 155464 10542504 9220184794 121418 190204 9220109491 390122 402179 013264 013308 152106 240306 013264 013346 070430 072361 152107 080212 080577 011708 013346 101125 200238 9220109490 013264 013308 152107 QTY PER CU 2 46 2 1 21 15 2 3 1 1 2 1 2 46 21 15 2 3 1 1 2 2 2 2 1 1 1 0.2 3 1 2 2 4 1 2 2 2 4 1 2 1 1 1 1 1 1 2 2 2 1 2 2 1 1 2 1 1 1 1 1 1 1 1 1 2 DESCRIPTION WASHER, SPRING, COIL, STEEL, FOR 3/4" BOLT WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, SQUAREHEAD, 3/4 IN, 12 IN, S, A307, GLV, 10, UNC SWITCH, VRT, AUTO, 14.4KV, 630A, SCADA-MATE CX WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. BOLT, MACH, SQ, NUT, 5/8"X12" BOLT, SQUAREHEAD, 3/4 IN, 14 IN, S, A307, GALV., 10, UNC BOLT, 5/8 IN, 10 IN, STEEL, GALV., OVAL EYE WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR 1/2" BOLT, SQUAREHEAD, 3/4 IN, 12 IN, S, A307, GLV, 10, UNC SWITCH, SCADAMATE UPRIGHT MTG WASHER, SPRING, COIL, STEEL, FOR 3/4" BOLT WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. BOLT, MACH, SQ, NUT, 5/8"X12" BOLT, SQUAREHEAD, 3/4 IN, 14 IN, S, A307, GLAV., 10, UNC BOLT, EYE, 5/8 IN, 10 IN, STEEL, GALV., OVAL EYE WASHER, ROUND, BELLEVILLE SPRING, FOR 1/2" BOLT WASHER, ROUND, FLAT, STAINLESS STEEL, 304, ALLOY, FOR 1/2" BOLT, SQUAREHEAD, 3/4 IN, 12 IN, S, A307, GLV, 10, UNC WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", SQUARE, FLAT, 13/16" HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8"X12" SWITCH, BY-PASS, SWITCH, BYPASS, 3-SLD BLADE DISC, 15KV, LBK H ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE RUBBER POLY GUARD, PVC, CABLE, 2-1/4"X10' BANDING, STAINLESS STEEL, 316, SS, 3/4", WIDE, .030, TH BANDING, BUCKLE, SS, 3/4", FOR BANDING ARRESTER, LIGHTNING, SEC 120-240 3 WIRE BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2"X2" NUT, 1/2 IN, A304, STAINLESS STEEL, HEX HEAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 2H-795AL WASHER, ROUND, RD, 1/2, SS, 1.375" OD BOLT, MACHINE, STAINLESS STEEL, HEX HEAD, 1/2"X2" NUT, HEX, 1/2 IN, A304, STAINLESS STEEL WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT LUG, COMP 4HOLE 795 AAC WASHER, ROUND, 1/2, SS, 1.375" OD CLAMP, HOT LINE, ALUMINUM, EXTRA LARGE 795 TIE, TOP F NECK 795 AL WIRE, COPPER, #6, HARD DRAWN, BR KIT, ANTENNA, UTILI-NET TAPE, ELECTRICAL, ELEC, 3/4X66'X.007 COMPOUND, INSUL, SEAL, PAD, 3-3/4" WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACHINE, 5/8 IN, 10 IN, STEEL, A-ASTM A307, GALV., MACH, BRACKET, STREET LIGHT, 6 ',W/30", RISE, GALV-STL WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, 3", SQUARE, CURVED, 13/16" HOLE BRACKET, FIBERGLASS, STAND-OFF, 20" STUD, LINE POST, 5/8"X1-3/4", INSULATOR STUD BOLT, MACH, SQ, NUT, 5/8"X12" INSULATOR, POST, TIE, TOP, 15/25KV, WITHOUT STUD INSULATOR, DEADEND, POLYMER, 25KV, SILICONE, RATED 15K BOLT, EYE, 5/8 IN, 10 IN, STEEL, GALV, OVAL EYE WASHER, 3", SQUARE, CURVED, 13/16",HOLE CLAMP, DE, SO, 336.4-954 ACSR, 397.5-1000 AL, COND RANGE WIRE, AAC, AAC 37STR 795 66 REE SWITCH, CTRL, AUTOMATED, INTELLI-TEAM-II WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SQUARE, 2-1/4", FLAT, 13/16" HOLE, GALV. BOLT, MACH, SQ, NUT, 5/8"X12" NOTES: 1. CHOOSE EITHER THE 900A OR 600A SCADA-MATE VERTICAL LOAD BREAK SWITCH. 2. SEE DWGS. 08.13-08A AND 08.13-08B FOR DESIGN SPECIFICATIONS. 3 2 SCADA MATE CX SWITCH 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. STANDARD MOUNTING ARRANGEMENT DWG. 08.13-08C NOTES: 1. TO EXTEND BATTERY CARRYOVER TIME, THE SWITCH TURNS OFF POWER TO THE LEDS AND LCD ON THE FACEPLATE WHEN THE CONTROL CABINET DOOR IS CLOSED. LEDS OVERCURRENT FAULT - COMES ON WHEN A, B OR C PHASE HAS AN OVERCURRENT CONDITION. A. IF OMNI-RUPTER IS CLOSED, LED TURNS OFF WHEN THREE-PHASE LINE VOLTAGE IS SENSED AND AFTER 45 MINUTES. B. IF OMNI-RUPTER SWITCH IS OPEN, LED TURNS OFF WHEN THE SWITCH IS CLOSED AND REMOTE/LOCAL IS TOGGLED MANUALLY OR VIA SCADA. C. IF OMNI-RUPTER SWITCH IS NORMALLY OPEN, LED TURNS OFF WHEN REMOTE/LOCAL IS TOGGLED MANUALLY OR VIA SCADA OR WHEN THE SWITCH IS CLOSED. REMOTE COMMUNICATIONS RCV/XMIT - BLINK WHEN COMMUNICATION SIGNALS ARE RECEIVED OR SENT. ERROR DETECTED - COMES ON FOR ANY OF THE FOLLOWING CONDITIONS: A. BATTERY CHARGER OVER-VOLTAGE. B. OPEN/CLOSE CONTACTS ARE BOTH OPEN OR BOTH CLOSED. C. TEMPERATURE SENSOR FAILURE. D. SWITCH ERROR SUCH AS BYPASS SWITCHES OPEN AND OMNI-RUPTER SWITCH IS BYPASSED. PROCESSOR STATUS - BLINKS ONCE PER SECOND WHEN CONTROL HAS POWER AND SOFTWARE IS RUNNING NORMALLY. BATTERY LOW - OFF WHEN BATTERY CHARGER WORKING NORMAL. ON WHEN BATTERY VOLTAGE DROPS BELOW A PRESET LIMIT. IF ON WITH AC POWER ON TO CONTROL, BATTERY MAY BE DEFECTIVE. BLINKS DURING ANY BATTERY TEST. 3 2 OMNI-RUPTER SWITCH R 1 0 8/11/10 REVISED GUINN GUINN ELKINS BY CK'D APPR. CONTROL FACEPLATE DWG. 08.13-10D AREA MUST BE WATERPROOF COAX CONNECTION HOW TO WATERPROOF THE ANTENNA COAX CONNECTION: 1. SCREW THE ANTENNA COAX CONNECTOR TOGETHER SO THAT IT IS TIGHT. 2. WRAP ELECTRICAL TAPE AROUND THE COAX CONNECTOR COVERING ONE INCH EITHER SIDE OF THE CONNECTION. 3. PLACE THE AQUA SEAL PAD ( CN 402179) SQUARELY OVER THE COAX CONNECTION AND WRAP IT SECURELY AROUND TO WATERPROOF THE CONNECTION. 4. WRAP ELECTRICAL TAPE AROUND THE AQUA SEAL WATERPROOFING PAD TO COVER THE ENTIRE AREA OF AQUA SEAL PLUS ONE INCH ABOVE AND BELOW THE SEAL. NOTES: 1. SEE DWG. 08.13-10A FOR DESIGN SPECIFICATIONS. 2. SEE DWG. 08.13-10C FOR BILL OF MATERIALS. 3 2 ANTENNA INSTALLATION R 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. FOR VERTICAL OMNI-RUPTER SWITCH DWG. 08.13-10E TANGENT TO DEADEND 5" 12" 2" 4" TYP. 18" #6 SD BC 36" #2 SD BC 2" 18" #2 SD BC TANK GROUND TO SYSTEM NEUTRAL 36" 2" AT TA C HM EN T 18" GU Y 72" #2 SD BC NEUTRAL #6 SD BC FRONT VIEW 4" SIDE VIEW DEADEND TO DEADEND 2" 18" 36" 2" 4" #6 SD BC #2 SD BC TANK GROUND TO SYSTEM NEUTRAL 2" 18" 36" 2" 18" 4" 2" 72" 2" 4" #2 SD BC #6 SD BC FRONT VIEW SIDE VIEW NOTES: 1. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. 3 2 1 0 10/13/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. VERTICAL CONSTRUCTION TO VERTICAL CONSTRUCTION WITH OIL SECTIONALIZER (FMO) R DWG. 08.04-06 1 8" 3 2 #6 SD BC 30" #6 SD BC NEUTRAL #6 SD BC FRONT VIEW SIDE VIEW BILL OF MATERIALS MACRO UNIT - CU ITEM NO. COMPATIBLE UNIT QTY REQ'D 1 AREQOH10F 2 2 3 SECT_ BKTCOLASTLXARMF 1 2 CATALOG NUMBER 220202 193511 070101 QTY PER CU 1 2 1 1 DESCRIPTION ARRESTER, LIGHTNING, 10KV HD MOV W/SILICONE CABLE, 600V #6 SOLID SD CU SECTIONALIZER BRACKET, LA AND CO TY A NOTES: 1. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. 2. ARRESTERS TO BE MOUNTED ON SOURCE AND LOAD SIDE. 3 SECTIONALIZER ASSEMBLY, 2 R 1 O 10/13/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. OIL TYPE, VERTICAL (FMO) DWG. 08.04-08 DEADEND TO DEADEND 9" 14" 34" 16" 23" LOAD 2" #2 SD BC 2" 6" 10" 24" 6" #2 SD BC 10" 20" 6" 10" 72" #2 SD BC #6 SD BC SIDE VIEW FRONT VIEW TANGENT TO DEADEND SOURCE 10" 4" 16" 4" 4" LOAD #6 SD BC 8" BOND CASE GROUND WITH CONNECTOR SUPPLIED ON BRACKET 6" 12" 12" 18" 12" 22" 6" 14" 72" #2 SD BC #2 SD BC 4" #6 SD BC SIDE VIEW FRONT VIEW NOTES: 1. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. 2. RUN #2 SD BC UNDER CROSSARM TO B0ND SECTIONALIZERS TO SYSTEM NEUTRAL. 3 2 1 0 10/13/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. HORIZONTAL CONSTRUCTION TO HORIZONTAL CONSTRUCTION WITH OIL SECTIONALIZER (FMO) R DWG. 08.04-12 SOURCE LOAD 6" 1 4 24" #2 WP COPPER CU RCRISERN2CUF 3 33" 2 5 27" #2 SD BC SEE NOTE 3 NEUTRAL FUSES STORED WITH BARRELS DOWN ON 3" STAPLE #6 SD BC FRONT VIEW SIDE VIEW NOTES: 1. ISSUE RECLOSER SEPARATELY. RECLOSER WILL COME ARRESTERS PRE-MOUNTED. 2. SEE DWG. 08.01-11 FOR CUTOUT MOUNTING DETAILS 3. EQUIPMENT CASE GROUND TO NEUTRAL TO BE #2 SD BC. 4. SEE DWG. 08.05-17B FOR BILL OF MATERIALS AND DETAILS ON ALUMINUM CROSSARM. 5. FOR TWO-PHASE HORIZONTAL INSTALLATIONS, ONLY INSTALL RECLOSERS AND SWITCHES ON OUTSIDE TWO PHASES. 3 1/6/16 LOOSIER BURLISON ADCOCK 2 11/17/15 LOOSIER BURLISON ADCOCK 1 8/7/14 SALAS GUINN ADCOCK 0 10/6/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED DEC DEM DEP DEF RECLOSER ASSEMBLY, HORIZONTAL CONSTRUCTION (FMO) X 08.05-17A 5 1 2 3 FRONT VIEW BILL OF MATERIALS CU ITEM NO. MACRO UNIT - COMPATIBLE UNIT QTY REQ'D 1 BKTCOLA8AALF 1 1 2 FUSE15CO100F 2 3 3 SW153COSBDF 4 6 4 5 KHLC40N6F RCRISERN2CUF 4 2 6 3 ITEM NUMBER 9220205263 10034908 10540102 10544005 221112 221112 269046 9220184790 193513 QTY PER CU 1 2 2 2 1 1 1 1 1 DESCRIPTION BRACKET, CUTOUT, BYPASS CUTOUT, 9 POSITION, AL, 97-1/2" BOLT, MCH, SQ, GLV, 5/8" X 12" WASHER, SQ., RB, CRV, 3" X 3" WASHER, LK, 5/8", COIL, DBL, GLV. CUTOUT, LB, 15KV, 100A, 16KA, 110KV BIL CUTOUT, LB, 15KV, 100A, 16KA, 110KV BIL BLADE, SOLID, CUTOUT, 15KV, 300A CLAMP, HOT LINE, ALUMINUM, SMALL CABLE, 600V, #2 SD CU, 7 STR. NOTES: 1. SEE DWG. 08.05-17A FOR DESIGN SPECIFICATIONS AND NOTES. 3 DEC DEM DEP DEF RECLOSER ASSEMBLY, 2 1 1/6/16 LOOSIER BURLISON ADCOCK 0 10/6/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED HORIZONTAL CONSTRUCTION (FMO) X 08.05-17B 5" 10" 20" 18" 38" 10" 42" 60" 44" 12" 12" #2 SD BC BOND TANK AND FRAME TO SYSTEM NEUTRAL NEUTRAL SECONDARY #6 SD BC 12" SECONDARY #6 SD BC FRONT VIEW SIDE VIEW NOTES: 1. CONTROL BOX AND SECONDARY REQUIRED FOR ELECTRONIC RECLOSER ONLY. 2. ISSUE RECLOSER AND ELECTRONIC CONTROL SEPARATELY. 3. RECLOSER MAY BE REVERSED IN HANGER TO ACCOMMODATE SOURCE AND LOAD POSITION. 4. SEE SECTION 01 FOR ADDITIONAL GROUNDING DETAILS. 3 RECLOSER ASSEMBLY, THREE-PHASE, 2 R 1 0 10/11/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. HORIZONTAL, 600 AMP SWITCH (FMO) DWG. 08.06-12 10" 20" 18" 38" 10" 55" NEUTRAL SEE NOTES 2 & 3 SIDE VIEW FRONT VIEW NOTES: 1. ENGINEER MUST SPECIFY JUMPER AND PRIMARY CONNECTOR SIZE. 2. REFER TO DWG. 08.12-01 FOR WIRING DIAGRAM. 3. RADIO SWITCH MUST BE SET FOR PURCHASE BY INSTALLING JUMPER PINS AS SPECIFIED IN CONTROL BOX. 3 2 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. LOAD CONTROL SWITCH ASSEMBLY, (VLR), THREE-PHASE HORIZONTAL WITH 600 AMP BYPASS (FMO) R DWG. 08.12-06 LOAD SOURCE 6 5" 6" 15 18-3/4" 43" 42" 11" 7 5" 26" 26" 41" 42" 14 5 26" 97" 97" 26" 6" 25 34" 21" 34" SURGE ARRESTER MOUNTING BRACKETS 2 29-1/8" 72" 3 1 LOCKOUT/TAGOUT BRACKET FOR SWITCH OPEN POSITION 4 MANUAL OPEN PULL-RING #2 SD BC 31'-8" MAX. FOR CONTROL CABLE 13 #6 SD BC 30" 9" MINIMUM RADIUS ON CABLE 4' ABOVE GROUND #6 SD BC FRONT VIEW NOTES: SIDE VIEW (LOOKING FROM LOAD SIDE) 1. SEE DWG. 08.13-10B FOR PLAN VIEW AND BILL OF MATERIALS. SEE DWG. 08.13-10C FOR OPTIONAL CONSTRUCTION BILL OF MATERIALS AND ADDITIONAL NOTES. 2. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE. 3. SEE DWG. 08.13-10E FOR ANTENNA INSTALLATION. 4. ARRESTERS SHOULD BE INSTALLED ON MOUNTING PADS PROVIDED ON BOTH SIDES OF THE OMNI-RUPTER SWITCH. THE ARRESTER SOURCE LEAD SHOULD BE CONNECTED TO THE 795 JUMPER JUST BEYOND THE OMNI-RUPTER 2-HOLE HIGH-VOLTAGE TERMINAL ON EITHER SIDE OF THE OMN-RUPTER SWITCH TO KEEP THE LEADS AS SHORT AS POSSIBLE. THE GROUND LEAD SHOULD BE RUN FROM THE GROUNDING CONNECTION ON THE ARRESTER INTERRUPTER TO THE OMNI-RUPTER SUPPORT FRAME. THIS LEAD MUST BE LONG ENOUGH FOR THE INTERRUPTER TO OPERATE, BUT SHORT ENOUGH TO CLEAR ADJACENT CONDUCTORS. ALL GROUND CONNECTIONS MUST BE VERY SECURE, ESPECIALLY THE #2 BC CONNECTION AT THE BASE OF THE OMNI-RUPTER SWITCH. 3 2 DEC 8/5/14 1 5/24/13 0 11/29/10 REVISED EANES EANES ADCOCK DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. DEM DEP DEF OMNI-RUPTER SWITCH STANDARD MOUNTING ARRANGEMENT (FMO) X 08.13-10A 34-3/8" 23-1/16" SOURCE LOAD 2 5 15 6 25 7 14 PLAN VIEW MACRO UNIT CN/CU ITEM NO 1 QTY REQ'D CATALOG NUMBER - 1 2 - 1 3 - 1 4 - 1 5 - 6 6 - 6 7 8 9 10 - - 11 - 6 12 - 12 13 - 3 14 - 3 15 - 3 16 17 18 - 3 1 35 6 19 20 21 22 23 24 25 BILL OF MATERIALS QTY PER COMPATIBLE UNIT DESCRIPTION 9220109487 9220109490 CU 1 1 SW, VRT, AUTO, 14.4KV, 900A, 35' CONTROL CABLE SW, CONTROL, AUTO, INTELLI-TM-II, WITH RADIO 013264 013308 152107 9220109491 390122 402179 013264 013308 152107 240306 220202 080577 011708 013308 013346 013264 101125 152123 152107 011708 155464 012277 013163 010928 10542504 155331 012277 013163 010928 10542504 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2 15 3 1 4 8 4 4 1 2 4 2 2 WASHER, SPG, CO, S, FOR 5/8" BOLT WASHER, 2-1/4", SQ, FLT, 13/16" HOLE BOLT, MACHINE, 5/8" X 12" KIT, ANTENNA, UTILI-NET, MA-30-AB RADIO TAPE, ELECTRICAL, 3/4" X 66' X .007 MIL COMPOUND, INSUL, SEAL, PAD, 3-3/4" WASHER, SPG, CO, S, FOR 5/8" BOLT WASHER, 2-1/4", SQ, FLT, 13/16" HOLE BOLT, MACHINE, 5/8" X 12" BRACKET, ST. LIGHT, 6', WITH 30" RISE, GALV. STEEL ARRESTER, 10KV, HD-MOV, SILICONE/RUBBER/POLYMER INSULATOR, 25KV, DEADEND, POLYMER BOLT, OVAL EYE, 5/8" X 10" WASHER, 2-1/4" SQUARE, FLAT, 13/16" HOLE WASHER, 3" SQUARE, CURVED, 13/16" HOLE WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT CLAMP, DE, SO, 336-1000 AL BOLT, MACHINE, 3/4" X 14" BOLT, MACHINE, 5/8" X 12" BOLT, OVAL EYE, 5/8" X 10" LUG, COMPR, 795 AAC, 4-HOLE (BOTTOM OF PKR SW) NUT, SS, HEX, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT BOLT, MACHINE, SS, HEX, HEAD, 1/2" X 2" WASHER, RD, 1/2", SS, 1-3/8" OD LUG, COMPR, 795 AL, 2-HOLE NUT, SS, HEX, COARSE THREAD WASHER, FLAT, ROUND, SILICON, BRONZE, FOR 1/2" BOLT BOLT, MACHINE, SS, HEX, HEAD, 1/2" X 2" WASHER, RD, 1/2", SS, 1-3/8" OD 323422 434122 434142 260123 152107 013308 013264 080212 072361 070430 014114 152107 013264 190204 121418 220139 190204 190312 013308 013264 013128 013407 9220184794 1 0.2 3 1 2 2 2 1 1 1 1 1 GUARD, CABLE, PVC 2-1/4" X 10' BANDING, 316, SS, 3/4" WIDE, .030 THICKNESS, 100', RL BANDING, BUCKLE, SS, 3/4",FOR BANDING SWITCH, 600 AMP BYPASS TYPE BOLT, MACH, SQ, NUT, 5/8" X 12" WASHER, SQUARE, 2-1/4", FLAT, 13/16", HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. INSULATOR, POST, TIE-TOP, 15/25KV, W/O STUD STUD, LINE POST, 5/8" X 1-3/4" BRACKET, FIBERGLASS, STAND-OFF, 20" SCREW, LAG, 1/2" X 4" BOLT, MACHINE, SQ, NUT, 5/8" X 12" WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT #6 BC, HDW TIE, PF, TOP F NECK 795 AL ARRESTER-SECONDARY, 120/240 3-WIRE WIRE, CU, BR, HRD, DRN, #6 (FOR ARRESTER GND) WIRE, #2 CU, BR, SDW, 7, STR, #2 (FOR POLE GND) WASHER, SQUARE FLAT, 5/8" WASHER, SPRING COIL, FOR 5/8" WASHER, SPRING, BELLEVILLE WASHER, STAINLESS STEEL, ROUND, FLAT, 1/2" HLC, 336 TO 795 1 1 6 1 2.4 1 42 21 1 1 1 NOTES: 1. SEE DWG. 08.13-10A FOR DESIGN SPECIFICATIONS AND DWG. 08.13-10C FOR OPTIONAL OPERATION/ INSTALLATION BILL OF MATERIALS AND ADDITIONAL NOTES. 3 2 OMNI-RUPTER SWITCH 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. STANDARD MOUNTING ARRANGEMENT (FMO) DWG. 08.13-10B MATERIALS NEEDED FOR OPTIONAL OPERATION/INSTALLATION MACRO UNIT CU ITEM NO. COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER QTY PER CU 1 - 1 9220109493 1 2 - 1 9220109494 1 12 010928 012277 013163 10542504 155408 2 2 4 2 1 1 2 4 2 2 1 4 8 4 4 1 4 8 4 4 1 1 1 1 1 1 1 1 1 3 - - 4 - 12 5 - 6 6 - 6 7 8 - 6 1 9 - 1 10 11 - 1 1 155331 012277 013163 010928 10542504 155457 012277 013163 010928 10542504 155464 012277 013163 010928 10542504 9220184794 012210 011708 013264 013308 013346 080577 101119 101125 DESCRIPTION RADIO, REPLACEMENT, UTILI-NET, SERIES II WANGATE RADIO FOR MOUNTING INSIDE CONTROL PANEL RADIO, REPEATER/RELAY, UTILI-NET, WANGATE, AC/DC, WEATHERIZED, SELF-CONTAINED BOLT, MACHINE, SS, HX, HD, 1/2" X 2" NUT, SS, HX, 304 ALLOY, COARSE, THREAD, 1/2" WASHER, FLT, RD SIL, BRN, FOR 1/2" BOLT WASHER, RD, 1/2", SS, 1-3/8" O.D. LUG, COMP 2H 336 AAC LUG, COMP 2H-795AL NUT, SS, HEX, COARSE THREAD WASHER, FLAT, ROUND, SILICONE, BRONZE, FOR 1/2" BOLT BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" WASHER, RD, 1/2", SS, 1-3/8" OD LUG, COMP, 4 HOLE, 336.4 AAC NUT, SS, HX, 304 ALLOY, COARSE, THREAD, 1/2" WASHER, FLT, RD SIL, BRN, FOR 1/2" BOLT BOLT, MACHINE, SS, HX, HD, 1/2" X 2" WASHER, RD, FLT, SS, 304 ALLOY, FOR 1/2" BOLT LUG, COMP, 4 HOLE, 795 AAC NUT, SS, HX, 304 ALLOY, COARSE, THREAD, 1/2" WASHER, FLT, RD SIL, BRN, FOR 1/2" BOLT BOLT, MACHINE, SS, HX, HD, 1/2" X 2" WASHER, RD, FLT, SS, 304 ALLOY, FOR 1/2" BOLT HLC, 336 TO 795 NUT, OVAL EYE, 5/8" BOLT, OVAL EYE, 5/8" X 10" WASHER, SPG, CO, S, FOR, 5/8" BOLT WASHER, 2-1/4", SQ, FLT, 13/16" HOLE WASHER, 3", SQ, CRV, 13/16" HOLE INSULATOR, POLYMER, 25KV, DEADEND, SILICONE, RATED 15K CLAMP, DE, SO, 2/0-556.5 ACSR, 2/0-556.5 AL, COND RANG CLAMP, DE, SO, 336.4-954 ACSR, 397.5-1000 AL, COND RANG NOTES: 1. SEE DWG. 08.13-10A FOR DESIGN SPECIFICATIONS AND DWG. 08.13-10B FOR PLAN VIEW. 2. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE AND DWG. 08.13-10E FOR ANTENNA CONSTRUCTION. 3. REPLACEMENT BATTERY FOR THE INTELLITEAM CONTROL IS CN 9220176380 . THESE ARE NOT KEPT IN STORES DUE TO SHELF LIFE. CONTACT PURCHASING FOR ORDERING AND LEAD TIME. 4. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE AND DWG. 08.13-10E FOR ANTENNA INSTALLATION. 5. BLADE CONTACTS ARE GREASELESS AND SELF-LUBRICATING SO NO GREASE IS NEEDED. 6. SHORTING BLOCKS FOR SENSOR SECONDARIES ARE SHIPPED INSTALLED IN SWITCH CONNECTOR. REMOVE AND SAVE SHORTING BLOCKS TO ALLOW SENSOR CABLE CONNECTION. 7. IF OPERATING SPRING IS CHARGED, ONLY A SINGLE PULL ON THE MOTOR OPERATOR PULL-RING IS REQUIRED. IF POWER IS LOST AND THE OPERATING SPRING IS FULLY DISCHARGED, USE A HOOK STICK TO PULL ON THE THE PULL-RING 7 TO 9 TIMES TO EFFECT A CHANGE OF STATE. 8. THE VT AND CT SENSORS SHOULD ALWAYS BE ORIENTED TOWARD THE SOURCE SIDE OF THE SWITCH. 3 2 OMNI-RUPTER SWITCH R 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. STANDARD MOUNTING ARRANGEMENT (FMO) DWG. 08.13-10C ONE-LINE 5" SUB FDR1 NOTE: IF YOU NEED AUTOMATED OMNI-RUPTER IN FDR2, FDR1 MUST BE RAISED TO POSITION OF DOTTED STACKED TOP CIRCUIT. FDR2 AOR 36" 19 LOAD SOURCE 6 36" 19 6" 25-1/4" 6" 14 18-3/4" 43" 42" 11" 19 7 5" #6 SD BC 26" 26" 41" 42" 13 5 26" #2 SD BC 97" 97" 26" 6" MANUAL OPEN PULL-RING LOCKOUT/TAGOUT BRACKET FOR SWITCH OPEN POSITION 34" 21" 34" SURGE ARRESTER MOUNTING BRACKETS 2 29-1/8" 60" 3 #2 SD BC 1 4 #2 SD BC #2 SD BC #6 SD BC 12 #6 SD BC FRONT VIEW SIDE VIEW (LOOKING FROM LOAD SIDE) NOTES: 1. SEE DWG. 08.13-11B FOR PLAN VIEW AND BILL OF MATERIALS. SEE DWG. 08.13-10A FOR OMNI-RUPTER CONTROLLER. 2. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE. 3. SEE DWG. 08.13-10E FOR ANTENNA INSTALLATION. 4. ARRESTERS SHOULD BE INSTALLED ON MOUNTING PADS PROVIDED ON BOTH SIDES OF THE OMNI-RUPTER SWITCH. THE ARRESTER SOURCE LEAD SHOULD BE CONNECTED TO THE 795 JUMPER JUST BEYOND THE OMNI-RUPTER 2-HOLE HIGH-VOLTAGE TERMINAL ON EITHER SIDE OF THE OMN-RUPTER SWITCH TO KEEP THE LEADS AS SHORT AS POSSIBLE. THE GROUND LEAD SHOULD BE RUN FROM THE GROUNDING CONNECTION ON THE ARRESTER INTERRUPTER TO THE OMNI-RUPTER SUPPORT FRAME. THIS LEAD MUST BE LONG ENOUGH FOR THE INTERRUPTER TO OPERATE, BUT SHORT ENOUGH TO CLEAR ADJACENT CONDUCTORS. ALL GROUND CONNECTIONS MUST BE VERY SECURE, ESPECIALLY THE #2 BC CONNECTION AT THE BASE OF THE OMNI-RUPTER SWITCH. 3 DEC 2 8/5/14 1 5/24/13 0 4/22/10 REVISED EANES EANES ADCOCK DANNA ADCOCK GUINN GUINN ELKINS BY CK'D APPR. DEM DEP DEF OMNI-RUPTER SWITCH STANDARD STACKED DOUBLE-CIRCUIT POLE ARRANGEMENT (FMO) X 08.13-11A 34-3/8" 23-1/16" 2 SOURCE 5 LOAD 6 14 13 7 PLAN VIEW BILL OF MATERIALS MACRO UNIT CU ITEM NO. 1 - COMPATIBLE UNIT QTY REQ'D CATALOG NUMBER - 1 2 - 1 3 - 1 4 - 1 5 - 6 6 - 6 7 8 9 - 6 2 15 10 - 6 11 - 12 12 - 3 13 - 3 14 - 6 15 16 17 18 19 20 21 22 23 24 - 3 1 35 - 9220109487 9220109490 013264 013308 152107 9220109491 390122 402179 013264 013308 152107 240306 220202 080577 011708 013264 013308 013346 101125 152123 152107 155464 010928 012277 013163 10542504 155331 010928 012277 013163 10542504 323422 014111 260123 152107 013308 013264 013264 014114 070431 072361 080212 152107 190204 121418 220139 190204 190312 013308 013264 013128 013407 9220184794 QTY PER CU 1 1 2 4 2 1 1 2 2 4 2 1 1 1 1 1 1 1 1 1 1 1 4 4 8 4 1 2 2 4 2 1 15 1 2 2 2 1 1 1 1 1 1 1 6 1 2.4 1 42 21 6 DESCRIPTION SW, VRT, AUTO, 14.4KV, 900A, 35' CONTROL CABLE SW, CONTROL, AUTO, INTELLI-TM-II, WITH RADIO WASHER, SPRING COIL, FOR 5/8" WASHER, SQUARE FLAT, 5/8" BOLT, MACHINE, 5/8" X 12" KIT, ANTENNA, UTILI-NET, MA-30-AB RADIO TAPE, ELECTRICAL, 3/4" X 66' X .007 MIL COMPOUND, INSUL, SEAL, PAD, 3-3/4" WASHER, SPG, CO, S, FOR 5/8" BOLT WASHER, 2-1/4", SQ, FLT, 13/16" HOLE BOLT, MACHINE, 5/8" X 12" BRACKET, ST. LIGHT, 6', WITH 30" RISE, GALV. STEEL ARRESTER, 10KV, HD-MOV, SILICONE/RUBBER/POLYMER INSULATOR, 25KV, DEADEND, POLYMER BOLT, OVAL EYE, 5/8" X 10" WASHER, SPRING COIL, FOR 5/8" WASHER, SQUARE FLAT, 5/8" WASHER, 3" SQUARE, CURVED, 13/16" HOLE CLAMP, DE, SO, 336-1000 AL BOLT, MACHINE, 3/4" X 14" BOLT, MACHINE, 5/8" X 12" LUG, COMPR, 795 AAC, 4-HOLE (BOTTOM OF PKR SW) BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" NUT, SS, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SI, BRONZE, FOR 1/2" BOLT WASHER, RD, 1/2, SS LUG, COMPR, 795 AL, 2-HOLE BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" NUT, SS, HEX, 304 ALLOY, COARSE THREAD WASHER, FLAT, ROUND, SI, BRONZE, FOR 1/2" BOLT WASHER, RD, 1/2, SS GUARD, CABLE, PVC 2-1/4" X 10' SCREW, LAG, 1/4" X 2" SWITCH, 600 AMP BYPASS TYPE BOLT, MACH, SQ, NUT, 5/8" X 12" WASHER, SQUARE, 2-1/4", FLAT, 13/16", HOLE, GALV. WASHER, SPRING, COIL, STEEL, FOR 5/8" BOLT, GALV. WASHER, SPRING COIL, FOR 5/8" SCREW, LAG, 1/2" X 4" BRACKET, FIBERGLASS, STAND-OFF, 30" STUD, LINE, POST, 5/8" X 1-3/4" INSULATOR, POST, TIE TOP, 15/25KV, W/O STUD BOLT, MACHINE, SQ, NUT, 5/8"X12" #6 BC, HDW TIE, PF, TOP F NECK 795 AL ARRESTER-SECONDARY, 120/240 3-WIRE WIRE, CU, BR, HRD, DRN, #6 (FOR ARRESTER GND) WIRE, #2 CU, BR, SDW, 7, STR, #2 (FOR POLE GND) WASHER, SQUARE FLAT, 5/8" WASHER, SPRING COIL, FOR 5/8" WASHER, SPRING, BELLEVILLE WASHER, STAINLESS STEEL, ROUND, FLAT, 1/2" HLC, 336 TO 795 NOTES: 1. SEE DWG. 08.13-11A FOR DESIGN SPECIFICATIONS AND DWG. 08.13-10A FOR OMNI-RUPTER CONTROLLER. 3 2 OMNI-RUPTER SWITCH STANDARD STACKED 1 5/24/13 0 11/29/10 REVISED DANNA ADCOCK HOFFMAN GUINN ELKINS BY CK'D APPR. DOUBLE-CIRCUIT POLE ARRANGEMENT (FMO) DWG. 08.13-11B 30" MIN. 5'-0" MAX. 2 LOAD SOURCE 9-7/8" SOURCE LOAD 13 LOAD 18" MIN. 24" SOURCE SOURCE LOAD 6" 11" 24" 9 7 12 15" 14" 18" MIN. 4-1/2" 6 8 4 1 3 #6 SD BC 24" #2 SD BC #2 SD BC MANUAL OPEN PULL-RING NEUTRAL 5 30" 9" MINIMUM RADIUS ON CABLE #6 SD BC 4' ABOVE GROUND MACROS SA90HS_M FRONT VIEW SIDE VIEW NOTES: 1. SEE DWG. 08.13-13B FOR PLAN VIEW AND NOTES. SEE DWG. 08.13-13C FOR BILL OF MATERIALS. 2. SEE DWG. 08.13-10C FOR OPTIONAL CONSTRUCTION BILL OF MATERIALS. 3. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE. 4. SEE DWG. 08.13-10E FOR ANTENNA INSTALLATION. 3 DEC 2 DEM DEP DEF OMNI-RUPTER SWITCH 1 8/5/14 EANES EANES ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED HORIZONTAL MOUNTING ARRANGEMENT (FMO) X 08.13-13A 13 2 SOURCE 12 SOURCE LOAD SOURCE LOAD SOURCE LOAD 6 7 5 1 LOAD 8 3 PLAN VIEW NOTES: 1. SEE DWG. 08.13-13A FOR FRONT AND SIDE VIEWS. 2. SEE DWG. 08.13-13C FOR BILL OF MATERIALS. SEE DWG. 08.13-10C FOR OPTIONAL CONSTRUCTION BILL OF MATERIALS. 3. SEE DWG. 08.13-10D FOR CONTROL FACEPLATE. 4. SEE DWG. 08.13-10E FOR ANTENNA INSTALLATION. 5. ARRESTERS SHOULD BE INSTALLED ON MOUNTING PADS PROVIDED ON BOTH SIDES OF THE OMNI-RUPTER SWITCH. THE ARRESTER SOURCE LEAD SHOULD BE CONNECTED TO THE 795 JUMPER JUST BEYOND THE OMNI-RUPTER 2-HOLE HIGH-VOLTAGE TERMINAL ON EITHER SIDE OF THE OMNI-RUPTER SWITCH TO KEEP THE LEADS AS SHORT AS POSSIBLE. THE GROUND LEAD SHOULD BE RUN FROM THE GROUNDING CONNECTION ON THE ARRESTER INTERRUPTER TO THE OMNI-RUPTER SUPPORT FRAME. THIS LEAD MUST BE LONG ENOUGH FOR THE INTERRUPTER TO OPERATE, BUT SHORT ENOUGH TO CLEAR ADJACENT CONDUCTORS. ALL GROUND CONNECTIONS MUST BE VERY SECURE, ESPECIALLY THE #2 BC CONNECTION AT THE BASE OF THE OMNI-RUPTER SWITCH. 3 DEC 2 DEM DEP DEF OMNI-RUPTER SWITCH 1 8/5/14 EANES EANES ADCOCK 0 11/29/10 HOFFMAN GUINN ELKINS BY CK'D APPR. REVISED HORIZONTAL MOUNTING ARRANGEMENT (FMO) X 08.13-13B BILL OF MATERIALS CU ITEM NO. MACRO UNIT 1 SA90HS M COMPATIBLE UNIT - QTY REQ'D 1 2 - 1 3 - 1 4 - 1 5 - 1 6 - 6 7 - 1 8 - 1 9 - 1 10 - 1 11 - 6 12 13 14 - 6 6 1 15 - 3 16 - 35 013128 013265 013308 152122 QTY PER CU 4 2 2 2 9220110451 1 080577 101125 013264 013308 152107 9220109490 390122 402179 9220109491 013264 013308 152107 240306 220202 013264 013308 152107 9220087868 9220091018 190204 9220117302 013264 152107 013308 013128 012277 010928 013407 010928 012277 013163 155464 10542504 010928 012277 013163 155331 10542504 9220184794 165277 220139 323422 014111 190312 3 6 2 4 2 1 1 2 1 2 4 2 1 1 1 1 1 1 1 1 1 2 2 2 4 12 12 24 6 6 6 6 6 2 2 4 1 2 1 1 1 1 45 1 CATALOG NUMBER DESCRIPTION WASHER, ROUND, BELLEVILLE, FOR 1/2" BOLT WASHER, SPRING COIL, FOR 3/4" BOLT WASHER, SQUARE FLAT, 5/8" BOLT, MACH, SQ, 3/4" X 12" SW, HORIZ, AUTO, 14.4KV, 900A, G35' SHIELDED CTRL CABLE IN LIQUIDTITE FLEXIBLE CONDUIT INSULATOR, 27KV, POLYMER DEADEND CLAMP, DEADEND, 795 AL WASHER, SPRING COIL, FOR 5/8" BOLT WASHER, SQUARE FLAT, 2-1/4" BOLT, MACH, SQ, 5/8" X 12" SWITCH, CTRL, AUTO TAPE, ELEC, 3/4" COMPOUND, INSUL, 3-3/4" KIT, ANTENNA, UTILI-NET WASHER, SPRING COIL, FOR 5/8" BOLT WASHER, SQUARE FLAT, 2-1/4" BOLT, MACH, SQ, 5/8" X 12" BKT, STREET-LIGHT, 6' WITH 30" RISE, GALV STL ARRESTER, LIGHTNING, 10KV WASHER, SPRING COIL, FOR 5/8" BOLT WASHER, SQUARE FLAT, 2-1/4" BOLT, MACH, SQ, 5/8" X 12" BKT, FBG, STAND-OFF INSUL, 25KV, POLYMER #6 BC, HDW SWITCH, BYPASS, 3 PHASE, 600A, 15KV, HORIZONTAL WASHER, SPRING COIL, FOR 5/8" BOLT BOLT, MACHINE, SQ. NUT, 5/8" X 12" WASHER, SQUARE FLAT, 5/8" WASHER, SPRING, BELLEVILLE NUT, SS, 1/2" BOLT, MACHINE, SS, 1/2" X 2" WASHER, SS, ROUND FLAT, 1/2" BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" NUT, SS, HEX, COARSE WASHER, FLAT, ROUND, BRONZE, 1/2" BOLT LUG, COMPRESSION, 4 HOLE 795 AL WASHER, ROUND,1/2",SS BOLT, MACHINE, SS, HEX HEAD, 1/2" X 2" NUT, SS, HEX, COARSE WASHER, FLAT, ROUND, BRONZE, 1/2" BOLT LUG, 2 HOLE, 795 AL WASHER, ROUND,1/2",SS HLC, 336 TO 795 CONNECTOR, WEDGE, 795-795 STR. ARR LIGHTNING SEC, 120/240V CABLE GUARD, 2-1/4" X 10" LAG SCREWS, 1/4" X 2" GROUND WIRE, 7 STR, #2 CU, 1 LB. NOTES: 1. SEE DWG. 08.13-13A FOR FRONT AND SIDE VIEWS. SEE DWG. 08.13-13B FOR PLAN VIEW AND NOTES. 2. SEE DWG. 08.13-10C FOR OPTIONAL CONSTRUCTION BILL OF MATERIALS. 3 2 OMNI-RUPTER SWITCH R 1 0 11/29/10 REVISED HOFFMAN GUINN ELKINS BY CK'D APPR. HORIZONTAL MOUNTING ARRANGEMENT (FMO) DWG. 08.13-13C NOTES: 1. METRICOM EQUIPMENT MOUNTED ABOVE THE NEUTRAL POSITION SHALL BE INSTALLED AND MAINTAINED ONLY BY PERSONS QUALIFIED TO WORK IN THE SUPPLY SPACE, PER SECTION 224 IN THE NESC. POLE TOP FRAMING AS REQUIRED 2. INSTALL ONLY ON POLES LOCATED ON PUBLIC RIGHT OF WAY. DO NOT INSTALL ON PRIVATE AREA LIGHTS NOR DECORATIVE POLES. O . T SE IN HA P M " T 43 ES S O CL PREFERRED NEUTRAL LOCATION 40" MIN. TO CLOSEST SECONDARY, SERVICE OR NEUTRAL 40" MIN. TO CLOSEST SECONDARY, SERVICE OR NEUTRAL LEVELING WEDGE SEE ANTENNA MOUNTING BRACKET DETAIL BELOW ANTENNA POWER CABLE METRICOM RADIO TRANSCEIVER USED TO SUPPORT WIRELESS MODEMS 10" 40" MIN. TO CLOSEST SECONDARY, SERVICE OR NEUTRAL POWER CABLE ALTERNATE NEUTRAL LOCATION LIGHTING BRACKETS PER DWG. 30.02-25 MOUNTING BRACKETS SUPPLIED BY METRICOM LEVELING WEDGE SUPPLIED BY METRICOM 6.8" 4" 3" 12" ANTENNA 3" MOUNTING BRACKET DETAIL 3 2 INTELLITEAM RADIO TRANSCEIVERS (FMO) 1 0 4/22/10 REVISED R GUINN GUINN ELKINS DWG. BY CK'D APPR. 08.13-15