CO Sensors High reliability Carbon Monoxide Transmitter/switch QQN | 4N"7%$ Integrated setpoint relay CO-EC-W Industrial Wall Mount CO-EC-D Duct Mount Long-life carbon monoxide sensing ▪ Ensure adequate air flow in parking lot garages ▪ Integrated display and pushbutton menus for field selectable scale, calibration, and operational modes ▪ Dual 4-20mA and 0-5v/0-10v output (jumper selectable) ▪ Integrated high-reliability solid-state set-point relay is ideal for direct control applications; easy to set up thanks to LCD ▪ Conduit ready construction Audible alarm Selectable outputs for compatibility High reliability reduces call backs ▪ UL2034 recognized electrochemical sensor element ▪ 5-year, long life sensor – no consumption of sensor active materials or electrodes 105 Replaceable long-life sensor LCD and push button menu for easy set-up and readings High accuracy for improved system performance ▪ Excellent selectivity to carbon monoxide – no false alarms +/-2% full scale ▪ High sensitivity....accurately measure low concentrations as typically found in parking garages ▪ Repeatability to within +/-5% ▪ Fast response time meets UL requirements Proudly Made in the U.S.A. 58 Ph: 9464 6555 QtG Fax: 9464 5155 CO Sensors ORDERING SPECIFICATIONS Power Supply Analog Outputs Digital Setpoint Output Display 12-30vdc/24vac , 100mA max. Dual Analog 3-wire 4-20mA and 0-5v/0-10v (2) (jumper) Output scaling 0-100ppm (default), 0-200ppm (jumper) Programmable (10/25/35ppm) Form A, 5A@30VAC/DC (1) CO-ECMounting Style 3-1/2 digit LCD Indicates CO ppm, setup menu features LED’s D = Duct W = Wall Green, Yellow, Red Green = Normal, Yellow = Relay, Red = Alarm Audible exposure alarm 90dB Piezo transducer 30 minutes above 100ppm per UL2034 Type Long-life Electrochemical Accuracy +/-10% full scale to 200ppm Response time 60 seconds to 90% reading Sensor Performance Certifications UL2034 recognized (sensor only) Repeatability <+/-5% Life expectancy 5 years SP, Setpoint (Relay ON 10/25/35ppm selectable (25ppm default) LCD Menu Setup Parameters FC, Fan cycle time (minimum 1 to 10 minutes (3 minutes default) RUN, Run mode Displays CO in ppm Temperature, continous -10 to 60oC Operating Environment Temperature, intermittent -40 to 70oC Humidity 5-99% RH, non-condensing Material Polycarbonate Enclosure Dimensions 4.53”h x 3.55”w x 2.3”d (1) One side of transformer secondary is connected to signal common. Dedicated transformer is recommended. (2) 15vdc power supply voltage required for 10 volt output. DIMENSIONS Replacement Sensor Elements CO- Replacement CO element TERMINAL CONNECTIONS 100/200 PPM 5V/10V SENSOR DEC SEL INC POWER COMMON V OUT mA OUT RELAY RELAY ALARM 1888 XXXTFOWBJODDPN Ph: 9464 6555 Fax: 9464 5155 VENT NORMAL 59