TRANSFORMERS SWITCHBOARDS CAPACITORS HV-LV CABLES & ACCESSORIES R Engineering Support Co., ltd. (Re Support) INSTALLATION MAINTENANCE OVERHAULING REPAIRING ELECTRICAL TESTING & TRANSFORMER OIL CHARACTERISTIC TESTING AND DGA TEST INDEX 1. “M4000 of DOBLE Engineering Company of USA.” Automated Insulation Analyzer for Insulation Power Factor Test. 2. “M4110 of DOBLE Engineering Company of USA.” Leakage Reactance Interface for Winding deformation which leads to an immediate transformer failure may be the result of several over current events. 3. “M5300 of DOBLE Engineering Company of USA.” Sweep Frequency Response Analyzer (SFRA) for Detect “Hidden” Transformer Faults. 4. Mobile Oil Treatment Plants. - 2000 litre/hour - MICAFIL of SWITZERLAND - 4000 litre/hour - MICAFIL of SWITZERLAND - 3000/6000 litre/hour - MICAFIL of SWITZERLAND - 6000 litre/hour - ARRAS-MAXEI of FRANCE - 6000/12000 litre/hour - KATO of JAPAN 5. “GP-1SRY-RIETSCHLE of Germany” Rotary Vane Vacuum Pump & Booster Pump with PIRANI Gauge for Transformer Drying Out. 6. 2 Sets of ”TR800-Multi-AMP, AVO International of ENGLAND” and “Three-Phase TTR, MEGGER Limited of ENGLAND” Transformer Ratiometer 7. 3 Sets of “BM 11 and BM 21 BIDDLE, AVO International of ENGLAND” and “MIT520 Megger Limited of ENGLAND” Insulation Resistance Tester 8. “BIDDLE of ENGLAND AVO International” High Potential Tester. 9. 2 Sets of “3235-YOKOGAWA of JAPAN” and “DET3TD MEGGER of ENGLAND” Earth Tester. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 INDEX 10. Insulating Oil Characteristic Testing Laboratory a. 5 Sets of Oil Testers for Dielectric Breakdown Voltage Testing b. Insulating Oil Power Factor Test by “M4000 of DOBLE Engineering Company of USA.” Automated Insulation Analyzer for Insulation Power Factor Test c. 2 Sets of Moisture Content Test by “AQUAPAL of ENGLAND“ and “METTLER TOLEDO of Switzerland” Automatic Karl Fischer Titration Water Content Tester d. Neutralization Number Test by “Mettler Toledo Type DL50 of Switzerland” Automatic Titrator Tester “ of GERMANY” Digital Tensiometer for Transformer oil e. Interfacial Tension Test by “K9-KRUSS Interfacial Tension Testing. f. PCB Screening Kit by “DEXSIL of USA” PCB Screening Kit g. Color Number Test by “PFX195/2-Tintometer of UK” 11. “VAISALA of FINLAND” On Line Moisture and Temperature Transmitter. 12. “IRCON of USA.” Thermographic Scanning. 13. 3 “RAYTEK of USA.“ Noncontact Temperature Measurement. 14. “CHAUVIN ARNOUX of FRANCE” Harmonic Meter Measurement. 15. “DOW CORNING” High Voltage Sylgard Coating Insulations. 16. 5 Sandblast, Epoxy Color Storage Tanks. 17. Service Performances for Power Transformers and “ABB”, “MR” OLTC Overhauling by Trained Teams. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 SERVICE VEHICLES & TRUCKS R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 1 On Site Automated Insulation Analyzer Type M4000 DOBLE Engineering Company USA. Detect Insulation Hazards Before They Result In Costly Apparatus Failures R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 M 4000 Automated Insulation Analyzer For 55 Years Double insulation analyzers have been testing * Bushings * Circuit Breaker / Reclosers * Power Transformers * Instrument Transformers * Regulators * Surge Arresters * Cables * Potheads * Generators * Motors * Capacitors * Insulators * Insulating Liquids Detect Insulation Hazards Before They Result In Costly Apparatus Failures. *Covered by patent rights issued and / or pending R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 (PIN 500-0100) OPERATING INSTRUCTIONS M4000 TECHNICAL SPECIFICATIONS (Specification Subject to Change) OUTPUT VOLTAGE OUTPUT POWER Range: 0 to 12 kV 3 kVA Distortion: 2% total harmonic distortion INPUT POWER for linear loads. 95-132, 190-264 V ac, auto selectable (Compares with normal building 120 V ac 47 to 63 Hz (no loss in performance when outlets.) used with portable generators) 20 A max. at 110 V, 10 A max. at 220 V OUTPUT CURRENT 100 mA continuous at 10 kV 300 mA intermittent at 10 kV MEASUREMENT ACCURACY AND RANGE POWER FACTOR TEST CURRENT Range: 0 to ±100.00% PF (±0 to 1.0000) Range: 0 to 5.000 A (auto ranging) Resolution: 0.01% PF (0.0001) 0 to 50.0 A when corrected or referred to 10 kV Accuracy : ±1% of reading, or Resolution: 0.0001 mA (0.1 mA) ±0.04% PF (0.0004) Accuracy: ±1% of reading, or ±1 mA CAPACITANCE TEST VOLTAGE Range: 0 to 2.7 mA (auto ranging) Resolution: 0.1 pF Accuracy: ±0.5% of reading, or ±1pF Range: 25 V to 12 kV Resolution : 1 V Accuracy: ±1.5% of reading, or ±1 V INDUCTANCE Range:132 henrys to 1000 kilohenrys at 10 kV Resolution: 0.01 millihenry Accuracy: ±1.5% of reading WATTS Range:0 to 2 kW, actual power 0 to 100 kW when corrected or referred to 10 kV Resolution: 0.5 mW Accuracy: ±2% of reading at 10 Kv ±0.3% of VA, or ±0.5 mW TEST FREQUENCY Range: 45 to 70 Hz Resolution: 0.1 Hz Accuracy: 0.1% of reading TEMPERATURE MEASUREMENT Range: -20oC to + 50oC Accuracy: ± 4 oC R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 (PIN 500-0100) OPERATING INSTRUCTIONS M4000 TECHNICAL SPECIFICATIONS (Specification Subject to Change) MAXIMUM INTERFERENCE CONDITIONS ELECTROSTATIC AT LINE FREQUENCY ELECTROSTATIC AT LINE FREQUENCY 15 mA, rms, maximum current into any 500 mteslas, 50 to Hz, in any direction lead or cable. Specifications applicable (typically) to maximum ratio of Interference current to specimen current of 20:1. ENVIRONMENTAL TEMPERATURE ELECTRO STATIC DISCHARGE o o Operating range: -20 C to + 50 C Meets I.E.C. 801-2 (1984) o o Storage range: -40 C to 70 C HUMIDITY SURGE WITHSTAND CAPABILITY 8% to 90%, non-condensing Instrument Controller Oil Cell Accessory Case Manual Bag Transporter (Optional) Meets ANSI/IEEE C37.90.1 SHOCK AND VIBRATION ASTM D999.75 transport shock test DIMENSIONS AND WEIGHTS : 18 x 12 x 3 inches : 6-1/4 H x 18 W x 14 D inches, approx. 25 lbs. : 9 x 8 x 8 inches, approx. 6 lbs. : 20 x 12 x 9 inches (cable bag 26 lbs.; 60’ HV Cable 18 lbs.) : 18 x 12 x 3 inches : 48-1/2 H x 20-1/2W x 19-1/2D inches, 33-1/2 lbs. M4000-494 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 (PIN 500-0100) OPERATING INSTRUCTIONS IX. DOCUMENTATION BASIC M4000 TECHNICAL FEATURES AND CAPABILITIES EXTRAORDINARY * Rugged construction * Portable - especially easy to handle and transport with optional field transporter Safety features ensure proper grounding Safe to operate - includes safety strobe light - audible warning indicator - designed to protect operator and apparatus * Simple to operate * High accuracy and sensitivity * Shielding (instrument and test leads) to reduce interference * Guard Circuit which does not require balancing for * Automated operation * Controller can be remotely located from the Instrument via optional 50 foot cable * Standard keyboard with built-in touch-sensitive “mouse” * Large 6” by 8” LCD display, viewable indirect sunlight and in darkness * Built-in 8-3/4” thermal plotter/printer 130 MB hard drive, 3-1/2” floppy drive, 4 MB RAM * RS-232 serial port * Stable, noise free, test voltage electronically synthesize * Test frequency can be independent of power-line general use * Provisions for making Ungrounded-Specimen Tests (UST) as well as Grounded-Specimen Tests (GST) * Ability to operate under conditions of electrostatic and electromagnetic interference * Can be used with the Doble Resonating Inductor in order to extend the capacitance range of test specimens to 1 mF (maximum) at 10 kV * Measures Actual or Equivalent 10-kV Values * Operates over a wide-temperature range * Uses internal resistance standard reference, which has been used in Doble 10-kV insulation test instruments since the early 1950s, thus avoiding disadvantages of capacitor standards under high humidity and rough handling frequency (stable readings with no loss in performance when used with portable generators) * 300 mA maximum current; 12 kV maximum test voltage * Accurate measurements with test voltage as low as 25 volts * Digital display of all parameters * Real-time analog bar graph display of V, I and W * Controller retains display and measuring mode when Instrument power is off * Retains high accuracy under the most severe conditions of electrostatic and electromagnetic interference due to unique Line-Frequency Modulation measuring technique R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 (PIN 500-0100) OPERATING INSTRUCTIONS IX. DOCUMENTATION BASIC M4000 TECHNICAL FEATURES AND CAPABILITIES EXTRAORDINARY * Automatic time and date recording * Measure and records ambient temperature (and humidity - pending) * Measures the power factor of all impedances (capacitive, resistive, and inductive) * Select series or parallel specimen model * Select measure Dissipation Factor or Power Factor * Built-in calibration and diagnostics * Capable of measuring transformer short-circuit impedance and voltage ratio * Built-in modem for electronic data transfer * Works with external test voltage and external reference (pending) * Optional Doble Test Assistance (DTA)m imbedded software program with Expert System (see sample test form) M4000-494 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 2 On Site Leakage Reactance Interface Type M4110 DOBLE Engineering Company USA. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 M 4110 LEAKAGE REACTANCE INTERFACE For Winding deformation which leads to an immediate transformer failure may be the result of several over current events. M 4110 M 4000 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 3 On Site Sweep Frequency Response Analyzer (SFRA) Type M5300 Doble Engineering Company USA. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 M 5300 SWEEP FREQUENCY RESPONSE ANALYZER (SFRA) For - Detect “hidden” transformer faults R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 4 Mobile Oil Treatment Plants 1. 2,000 litre / hour - Micafil, Switzerland 2. 4,000 litre / hour - Micafil, Switzerland 3. 3,000 / 6,000 litre / hour - Macafil, Switzerland 4. 6,000 litre / hour - Maxei, France 5. 6,000 / 12,000 litre / hour - Kato, Japan R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Oil Treatment Plant 2 Sets “MICAFIL - SWITZERLAND” Capacity 2,000 litre / hour and 4,000 litre / hour (Fixed Installation on The Trucks) R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MACAFIL Technical Specification Type of Plant Oil Throughput Operating Pressure at Final Oil Passage Vacuum Pump Inlet Flow Capacity (Nominal) Total Power Input Heater Output Vacuum Pump Motor Output Feed Pump Motor Output Pope Connections : - Oil Inlet - Oil Delivery - Exhaust Total Volume of Plant VH 020 2,000 litre / hour < 1 mbar 33.4 m3 / h 34 kW 30 kW 1.1 kW 1.1 kW DN 32, R1 1/4” DN 32, R1 1/4 DN 32 276 dm3 MACAFIL Technical Specification Type of Plant Oil Throughput Operating Pressure at Final Oil Passage Vacuum Pump Inlet Flow Capacity (Nominal) Total Power Input Heater Output Vacuum Pump Motor Output Feed Pump Motor Output Pope Connections : - Oil Inlet - Oil Delivery - Exhaust Total Volume of Plant VH 040 4,000 litre / hour < 1 mbar 66.8 m3 / h 65 kW 60 kW 2.2 kW 2.2 kW DN 50 DN 50 DN 40 ~ 420 dm3 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Oil Treatment Plant Capacity 3,000 litre / 6,000 litre / hour “MICAFIL - SWITZERLAND” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 6,000 litre / hour “MAXEI - FRANCE” Oil Treatment Plant R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MAS6000 TYPE OIL TRETMENT EQUIPMENT 1.Treatment Process The MAS6000 type oil treatment plant has been designed to treat dielectric oil having a 50 ppm moisture content and a dissolved gas content of approx. 10% by volume before being treated. With an appropriate pass number through the system, the clean treated oil goes out at a maximum temperature of 80 oC with a moisture content below 3 ppm* and a dissolved gas content of approx. 0.1% by volume*. This restores the oil dielectric strength to a value in excess of 75 kv. The above figures and reached with oil having a 10-2mbar distillation curve at a temperature of 80 oC. * Theoretical value depending on the measuring device accuracy and reanging from about 2 to 5 ppm. 2.Principle of Operation The dielectric fluid enters the plant through an inlet strainer, and then passes through an inlet oil pump and into an oil heater, where it is heated by immersion heaters. After a fine filtration on cartridge, the dielectric fluid is sprayed into a vacuum chamber on a basket of “Raschig” rings”. Contaminants being eliminated, the clean treated fluid flows through the outlet oil pump. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MAS6000 TYPE OIL TRETMENT EQUIPMENT 3.Technical Data 6,000 l/hr. - Flow rate - Heating power - Total power - Filtration on cartridge - Vacuum motor-pump - Flow to atmosphere - Ultimate vacuum against closed suction - Vacuum - Auxiliaries supply - Electrical equipment 4.Specifications 4.1 Inlet Oil Motor-Pump Maxi. flow rate Lifting Height at 4 m3/hr Motor power Speed of rotation 78 kW 96 kW +1 m nominal single stage 240 m3/hr 0.08 mbar 400 V - 3 phases - 50 Hz 220 V with transformer Tropicalised 9,500 l/hr 40 m CE 4 kW 1,500 r.p.m. 4.2 Heater Made of a parallelepiped heating member. Fitted with 10 flanged immersion heaters with resistance : unit power 7.8 kW - 2 heater speeds : 24 kW and 54 kW : total heating power : 78 kW. Outlet linked to the filter through a safety valve, a regulation probe, a safety thermostat, a by-pass and a manometer graduated from-1 to 5 bars. R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MAS6000 TYPE OIL TRETMENT EQUIPMENT 4.3 Filtering system Filter head made of cast iron. Cartridge casing made of steel and screwed on the filter. A consumable cartridge is used to filter the dielectric fluid. Filtration threshold is 1+-m nominal. Filter fitted with a electric clogging indicator. Filter outlet linked to the dehydration tank through a manifold fitted with a flow regulation valve and a flow indicator with alarm. 4.4 Dehydration Tank Cylindrical construction. Made of mild steel. Fitted with 1 spraying blockhead and 1 set Raschig rings. 4.5 Outlet Oil Vacuum Motor pump Maxi. flow rate Lifting height at 4 m3/hr Motor power 7,000 l/hr 35 m CE 3 kW Speed of rotation 1,500 r.p.m. 4.6 Vacuum Motor pump Flow rate Ultimate vacuum Motor power Speed of rotation 240 m3/hr 0.08 mbar 5.5 kW 1,500 r.p.m. Oil capacity 8.5 liters R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Oil Treatment Plant 6,000 / 12,000 litre / hour KATO ELECTRIC MFG. Japan R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66 -2) 322-0250 5 Rotary Vane Vacuum Pump and Booster Pump with PIRANI Gauge for Power Transformer Drying Out R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Rotary Vane Vacuum Pump Combined with Roost Pump Capacity 14,000 litre/min. “RIETSCHLE - GERMANY” complete with PIRANI Gauge R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 PIRANI Vacuum Gauge for Transformer Drying Out R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 6 Transformer Ratiometer “TR800 -Multi-AMP-England” AVO International and “Three-Phase TTR” MEGGER Limited R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Three Phase Transformer Ratio Meter “Multi-Amp” AVO International Model TR-800 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 “MEGGER - ENGLAND” Three-Phase TTR Transformer Turns Ratio Test Set R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 7 Insulation Resistance Model BM 21 Model BM 11 AND Model MIT 520 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MEGGER Test Model BM 21, Model BM 11 and Low Ohm Resistance “BIDDLE-AVO International - ENGLAND” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 MEGGER Test - ENGLAND “MIT 520” 5 kV and Insulation Resistance Tester R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 8 High Potential Tester “BIDDLE - ENGLAND” AVO INTERNATIONAL R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 High Potential Tester (120KV) “BIDDLE - ENGLAND” Heat Shrinkable, Termination Kit “RAYCHEM - USA” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 9 Earth Tester “YOKOGAWA - JAPAN” with Calibration Certificate and “MEGGER - ENGLAND” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Earth Tester “YOKOGAWA - JAPAN” EARTH Tester Type 3235 2 SETS “MEGGER - ENGLAND” Earth Tester Type DET3TD R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 10 Insulating Oil Characteristic Testing Laboratory R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 4 Sets of Oil Testers for Dielectric Breakdown Voltage Testing R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 4 Sets of Oil Testers for Dielectric Breakdown Voltage Testing BAUR - AUSTRIA FOSTER - ENGLAND R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Automated Insulation Analyzer Type M4000 DOBLE Engineering Company USA Detect Insulation Hazards Before They result in costly apparatus failures R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 M 4000 Automated Insulation Analyzer For 55 Years Double insulation analyzers have been testing * Bushings * Circuit Breaker / Reclosers * Power Transformers * Instrument Transformers * Regulators * Surge Arresters * Cables * Potheads * Generators * Motors * Capacitors * Insulators * Insulating Liquids - Transformer Oil - Lubricanting Oil Detect Insulation Hazards Before They Result In Costly Apparatus Failures. *Covered by patent rights issued and / or pending R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 2 Sets KARL FISCHER TITRATION WATER CONTENT TESTER R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 KARL FISCHER Titration Water Content Tester “AQUAPAL - ENGLAND” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 “METTLER TOLEDO - SWITZERLAND” SN. 5127133305 METTLER TOLEDO DL39 Coulometers Volumetric Titrators Stromboli KF Sample Changer From 1 ppm to 100% Karl Fischer Water Content Determination R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Neutralization Number Measuring “Mettler Toledo Type DL50 of Switzerland” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 “METTLER TOLEDO - SWITZERLAND” SN. 5127143883 THE EASY ENTRY TO FULLY AUTOMATIC TITRATION : METTLER TOLEDO DL50 GRAPHIX Simply Fully Automatic Neutralization Number Measuring DL50 Graphix R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Interfacial Tension Tester “ “KRUSS - GERMANY” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 PCB Screening Kit R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 PCB Screening Kit Disposable Test Kit for determining PCB Contamination in transformer oil Remark : Results < 50 = Non PCB, > 50 = Contamination, > 500 = Pure PCB R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Color Number Test “PFX195/2-TINTOMETER - UK” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 LOVIBOND PFX195 - ENGLAND for Color Testing R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 11 On Line Moisture and Temperature Transmitter for Oil “VAISALA - FINLAND” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 “VAISALA - FINLAND” HMP228 Moisture and Temperature Transmitter for Oil SN. W5050049 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 12 Thermographic Scanning “IRCON - USA” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 13 3 Sets of Non Contact Temperature Measurement “RAYTEK” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 14 Harmonic Meter “CHAUVIN ARNOUX - FRANCE” R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 15 “DOW CORNING” High Voltage Sylgard Coating Insulators R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 “SYLGARD” High Voltage Insulator Coating for “TOSHIBA” 130 MVA. 33 KV. Location : TR-3 Main Substation By R Engineering Support Co., Ltd. on March 14, 2001 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 16 5 Storage Tanks R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 5 Inside - Outside Sandblast Storage Tanks 11,000 Litre 18,000 Litre 2 pcs. 20,000 Litre 22,000 Litre 11,000 Litre 18,000 Litre 18,000 Litre 20,000 Litre 22,000 Litre R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 17 Service Performances for Power Transformers Main Tank Transformer oil treatment Transformer overhauling Leaked repairing Transformer drying out Internal inspection and repairing Transformer installation Electrical Test & Commissioning Test R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 Service Performances for Power Transformers “ABB” & “MR” On Load Tap Changer by trained staff Inspection & overhauling Oil replacing Contact replacing Accessory replacing Diverter Switch replacing Voltage Regulator replacing R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 ดำ�เนินการติดตั้ง Maintaining Contact และ Interlocking Contact โดยไม่ ต้องหยุดใช้งานหม้อแปลงไฟฟ้า เพื่อทดแทนของเก่าที่เริ่มสึกและล้าตามอายุใช้งาน จนทำ�ให้ Mechanical System สูญเสียความเป็นอัตโนมัติของ On Load Tap Changer ผลิตภัณฑ์ ABB รุ่น UZFRT 650/300 ของหม้อแปลงไฟฟ้าขนาด 50 MVA ระบบแรงดัน 115-22 KV ผลิตภัณฑ์ MEIDEN ปีผลิต 1990 R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250 On Load Tap Changer Arcing Repairing On Site Main Tank Rated Power Primary Secondary Mfg. Year : : : : : OLTC Cabinet 12.5 MVA 3 Ph. 50 Hz. Mfg. : ASEA 22,000 V. Type : UZBLN 250/500 7,000 V. ASEA 1973 Before Repairing After Repairing R ENGINEERING SUPPORT CO., LTD. TEL. (66-2) 322-0250