SHURFLO WATER BOOST SYSTEMS ® 804-067 MAXI 3/4" [19 mm] NPT 804-068 MAXI 1/2" [12.7 mm] BARB WB2-LVPO-02 MEDIUM 3/8" [9.5 mm] 804-034 MEDIUM 3/8" [9.5 mm] BARB 804-042 MINI 3/8" [9.5 mm] BARB CAUTIONS & WARNINGS WARNING: Risk of electrical shock. The pump is supplied with a grounding connector and grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. To prevent electrical shock, disconnect power before initiating any work. In the case of pump failure, the motor housing and/or the pumped fluid may carry high voltage to components normally considered safe. WARNING: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. WARNING: Never pressurize the accumulator tank higher than its maximum operating pressure of 100 psi [6.9 bar, 690 kPa] limit. Never expose the tank to higher than 100ºF [37.8ºC] ambient temperature environment. WARNING: The device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the device. CAUTION DO NOT adjust the pump pressure switch setting. Switch setting will not significantly alter flow rate or pressure. Improper adjustment may cause severe overload or premature failure, not covered under warranty. CAUTION DO NOT operate the pump at pressures which cause the motor to exceed the amperes rating indicated on the nameplate. The pump is equipped with thermal breakers to interrupt operation due to excessive heat. Once the temperature of the motor is within proper limits, it will automatically reset and the pump will start operation without warning. The motor is equipped with an integral, non-serviceable fuse. Pumps which have an “open” fuse are not covered under the limited warranty. ACCUMULATOR STORAGE/FLOW-RATES Shurflo Water Boost Systems by Pentair are designed for applications when low, fluctuating, or no water pressure exists. The pump and accumulator maintain consistent water pressure to a source (for a given duration) as long as incoming water is sufficient. Depending upon the Water Boost System model, support of up to four (4) non-carbonated valves in moderate volume accounts is achievable. The Medium and Maxi Water Boost Systems may be used to supply water to a carbonator for back-up during short periods of insufficient water pressure. The pump pressurizes the accumulator to 90 psi [6 bar, 600 kPa]. Consult the water boost system performance charts for projected length of flow and/or back-up. The pump is CE and C-Tick listed. INSTALLATION INSTRUCTIONS WARNING: DO NOT pre-charge the accumulator with CO2. In the event of failure, carbonated water will react with brass components in system equipment. Use clean, dry air or nitrogen. WARNING: A qualified electrician, in accordance with all local electrical codes, should perform all electrical outlet (receptacle) wiring connections. Circuit protection is dependent on the individual application requirements. Failure to provide proper circuit protection may result in a motor failure, which is not covered under warranty. CAUTION An RCD or GCFI having a maximum residual current of 30mA must be included in the fixed wiring in accordance with the wiring rules. 1. The water booster system is to be installed between the water source and non-carbonated valve(s) and/or carbonator (see Installation figure on page 3). Turn off city water supply before installation. FILTRATION & PROCESSING SOLUTIONS INSTRUCTION AND OPERATION GUIDE NOTE 1: D epending upon your application, it is recommended that a Shurflo® water pressure reducer valve of appropriate pressure be installed after the filter system before the line is teed just prior to the carbonator and the non-carb valves. 2. Remove the power cord, power supply and reclosable adhesive backed fasteners from their packaging. Plug the pump's power cord into the supply's IEC female socket. Attach the power supply to a clean, flat surface using the included reclosable adhesive backed fasteners. The power supply should be located such that liquids can not drip or splash onto it. Connect the AMP connectors at the power supply and pump together. 3. Secure water booster to a solid surface with four (4) 3/8‑inch (9.5mm) diameter lag screws with sufficient length through holes in tank legs and into wood stud, or suitable fastener into solid surface to support 72 pounds (32.7 kg). It may be mounted vertically or horizontally near the city water entry; 2-gallon water booster will fit under most drop-in dispenser cabinets. Be certain the pre-charge valve is accessible for checking/filling the tank. 4. Use NSF® listed, high pressure braided 3/8-inch ID [9.5 mm], 1/2-inch [12.7mm] or 3/4-inch [19mm] tubing to connect the inlet/outlet ports depending on inlet and outlet port size. Secure all tubing connections with SS, step-less Oetiker® clamps unless using 3/4-inch [19mm] NPT connections. Cable-tie all tubing securely to prevent kinks or sags that can inhibit performance or cause damage to the pump. 6. In most cases, 50 psi [3.4 bar, 340 kPa] will provide the required pressure at a typical beverage dispense system. For best pump performance, set accumulator pre-charge pressure at approximately 20 psi [1.3 bar, 130 kPa] below maximum pump pressure (as stated on the pump label), and/or at approximately the pump turn-on pressure. For further information, consult the factory. 7. Turn ON incoming water supply. 8. Plug in power supply to water boost system and carbonator. 9. Open the dispenser valves and purge air/water from tubing/accumulator. Close the dispenser valve(s) and let the pump fill the accumulator. The pump may not obtain shut-off pressure if excessive air is trapped within the system. Repeat this step 3-5 times as necessary before taste testing. Note 2: I f subject to freezing temperature, the pump, tubing and accumulator tank MUST be drained of all water. Note 3: T he accumulator tank pre-charge should be checked bimonthly or as necessary. All outlet water pressure must be depleted from tank prior to checking or recharging. Remove cap to precharge tank. Recap after charging tank. 5. Remove accumulator air fitting cap and pre-charge with clean, pressurized air or nitrogen. Tank should be pre-charged at the minimum required pressure of the application. Check accumulator label for pre-charge pressure. Replace air fitting cap securely. Check pressure bimonthly. WATER BOOST SYSTEM PERFORMANCE 60 Mini Water Boost 60 PSI Pump Flow Rate 4.0 55 3.7 50 3.4 1.25 oz p/sec (37 ml p/sec) Units tested with 50 psi [3.45 bar, 345 kPa] pre-charge and 20 psi [1.4 bar, 140 kPa] city water pressure. 2 Gallon Water Boost 90 80 75 Pressure (PSI/Bar) PSI BAR Liquid Outlet (PSI/Bar) Units tested with 40 psi [2.76 bar, 276 kPa] pre-charge and 20 psi [1.4 bar, 140 kPa] city water pressure. 2.5 oz p/sec (74 ml p/sec) 5 6 7 8 9 10 60 50 20 11 10 Mini Water Boost 90 PSI Pump 15 20 25 30 35 Time (Seconds) 85 80 1.25 oz p/sec (37 ml p/sec) 5.4 2.5 oz p/sec (74 ml p/sec) 6 7 8 9 10 Time (Seconds) INSTRUCTION AND OPERATION GUIDE 11 45 50 55 60 4.0 oz p/sec (118 ml p/sec) 90 Flow Rate 6.2 80 5.8 40 6 Gallon Water Boost 5.5 5 2 10 6.9 Flow Rate 6.0 8.0 oz p/sec (237 ml p/sec) 5 100 Pressure (PSI/Bar) Liquid Outlet (PSI/Bar) 90 2.0 oz p/sec (59 ml p/sec) 4.0 oz p/sec (118 ml p/sec) 6.0 oz p/sec (177 ml p/sec) 30 Time (Seconds) PSI BAR Flow Rate 40 6.0 oz p/sec (177 ml p/sec) 8.0 oz p/sec (237 ml p/sec) 10.0 oz p/sec (296 ml p/sec) 70 E 12.0 oz p/sec (355 ml p/sec) 4.8 60 4.1 50 3.4 40 2.8 30 2.1 E 20 1.4 10 0.7 10 20 30 40 50 60 70 Time (Seconds) 80 90 100 110 120 WATER BOOST SYSTEM INSTALLATION DIAGRAM Mounting Holes (Reference Only) Dispenser Maxi 12" (305 mm) Still Water Medium 9.5" (241 mm) 2 x 8.5" (216 mm) Cold Plate Water Filter Concentrate Filtered Water Carbonated Water CO2 SHURflo WPRV Carbonator Mini Water Boost 804-042 Medium Water Boost 804-034 9.5" (241 mm) Medi: 4.75" (121 mm) Maxi: 9.75" (248 mm) City Water Water Boost System Maxi Water Boost 804-067 & 804-068 9.5" [241 mm] 16" [406 mm] 10.5" [267 mm] 13.5" [343 mm] 10.5" (267 mm) 12" [305 mm] 11.5" [292 mm] 9.5" [241 mm] 4.6" (117 mm) deep 17" [432 mm] 19" [483 mm] 10.5" [267 mm] 13" [330 mm] SPECIFICATIONS PUMP SPECIFICATIONS Motor Design (Model 8025-998-338) 100 – 240 VAC / 50–60 Hz to 24 VDC permanent magnet; thermally protected with a non‑replaceable integral fuse Duty Cycle Intermittent (max. run time 20 min. within one hour) Turn-On/Off Pressure 70 PSI [4.8 bar, 480 kPa] / 90 PSI [6.2 bar, 620 kPa] Recommended Maximum Inlet Pressure 30 psi [2 bar, 200 kPa] Check Valve Internal (prevent reverse flow) Temperature Limits 34º – 100ºF [1.1º – 37.8ºC] Port / Fitting QD ports female / 3/8", or 1/2" barb fittings or 3/4" NPT fittings TANK SPECIFICATIONS Mini 804-042 Medium 804-034 Maxi 804-067 & 804-068 Total Volume (air/liquid) 21 oz [0.62 L] 2 gal [7.6 L] 6 gal [22.7 L] Approximate Draw Down Volume* 8 oz (0.22 L) 0.75 gallons (2.8 L) 3.1 gallons (11.7 L) Bladder Material Butyl Chlorbutyl Chlorbutyl Housing Material Glass Filled Nylon Stainless Steel Stainless Steel Temperature Limits 34º – 100º F [1.1º – 37.8º C] 34º – 100º F [1.1º – 37.8º C] 34º – 100º F [1.1º – 37.8º C] Maximum Working Pressure 100 psi [6.9 bar, 689 kPa] 100 psi [6.9 bar, 689 kPa] 100 psi [6.9 bar, 689 kPa] * Drawdown volume varies with tank pre-charge, pump operating pressure and city water pressure. Specifications reflect tests at 50 psi [3.4 bar, 340 kPa] pre-charge w/20 psi [1.3 bar, 130 kPa] city water pressure, 90 psi [6.2 bar, 620 kPa] pump pressure. INSTRUCTION AND OPERATION GUIDE 3 LIMITED WARRANTY INLINE WATER FILTER SYSTEM Shurflo® Water Boost Systems by Pentair® are warranted to be free of defects in material and workmanship under normal use, for a period of one (1) year from the date of manufacture, or one (1) year of use, with proof of purchase. This limited warranty will not exceed two (2) years, in any event. The limited warranty will not apply to Shurflo Water Boost Systems that were improperly installed, misapplied, or incompatible with fluids or components not manufactured by Pentair. Water Boost System failure due to foreign debris is not covered under the terms of this limited warranty. Pentair will not warrant any Water Boost System which is damaged or modified outside the Pentair factory. Returns are to be shipped postage prepaid to the service center; Pentair Filtration Solutions, LLC. Pentair shall not be liable for freight damage incurred during shipping, package returns carefully. N15188 Pentair Shurflo Technical Support: Tel: 800,942.1153 (US Only) • 630.307.3000 Main Email: servicespecialist@pentair.com FILTRATION & PROCESSING SOLUTIONS EVERPURE-SHURFLO WORLD HEADQUARTERS, 1040 MUIRFIELD DRIVE, HANOVER PARK, IL 60133 USA • WWW.EVERPURE.COM 800.942.1153 (US ONLY) • 630.307.3000 MAIN • 630.307.3030 FAX • CSEVERPURE@PENTAIR.COM EMAIL EVERPURE-SHURFLO AUSTRALIA, 1-21 MONASH DRIVE, DANDENONG SOUTH, VIC 3175, AUSTRALIA 011.1300.576.190 TEL • AU.EVERPURE@PENTAIR.COM EMAIL EVERPURE-SHURFLO CHINA, 21F CLOUD 9 PLAZA, NO 1118, SHANGHAI, 200052, CHINA 86.21.3211.4588 TEL • 86.21.3211.4580 FAX • CHINA.WATER@PENTAIR.COM EMAIL EVERPURE-SHURFLO INDIA, GREEN BOULEVARD, B-9/A, 7TH FLOOR - TOWER B SECTOR 62, NOIDA - 201301 91.120.419.9444 TEL • 91.120.419.9400 FAX • INDIACUSTOMER@PENTAIR.COM EMAIL EVERPURE-SHURFLO EUROPE, PENTAIR WATER BELGIUM BVBA, INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN, 30 B-2200 HERENTALS, BELGIUM +32.(0).14.283.500 TEL • +32.(0).14.283.505 FAX • SALES@EVERPURE-EUROPE.COM EMAIL EVERPURE-SHURFLO JAPAN INC., HASHIMOTO MN BLDG. 7F, 3-25-1 HASHIMOTO, MIDORI-KU, SAGAMIHARA-SHI KANAGAWA 252-0143, JAPAN 81.(0)42.775.3011 TEL • 81.(0)42.775.3015 FAX • INFO@EVERPURE.CO.JP EMAIL EVERPURE-SHURFLO SOUTHEAST ASIA,18 BOON LAY WAY, #04-110/111, TRADEHUB 21, 609966, SINGAPORE 65.6795.2213 TEL • FAX: 65.6795.2219 FAX • CSEVERPURE@PENTAIR.COM EMAIL All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. © 2012 Pentair Filtration Solutions, LLC. All Rights Reserved. 911-1043 Rev A DE12